WorldWideScience

Sample records for abdominal ct scanning

  1. Experimental study of abdominal CT scanning exposal doses adjusted on the basis of pediatric abdominal perimeter

    International Nuclear Information System (INIS)

    Wei Wenzhou; Zhu Gongsheng; Zeng Lingyan; Yin Xianglin; Yang Fuwen; Liu Changsheng

    2006-01-01

    Objective: To optimize the abdominal helical CT scanning parameters in pediatric patients and to reduce its radiation hazards. Methods: 60 canines were evenly grouped into 4 groups on the basis of pediatric abdominal perimeter, scanned with 110,150,190 and 240 mAs, and their qualities of canine CT images were analyzed. 120 pediafric patients with clinic suspected abdominal diseases were divided into 4 groups on the basis of abdominal perimeter, scanned by optimal parameters and their image qualities were analyzed. Results: After CT exposure were reduced, the percentages of total A and B were 90.9 % and 92.0 % in experimental canines and in pediatric patients, respectively. Compared with conventional CT scanning, the exposure and single slice CT dose index weighted (CTDIw) were reduced to 45.8%-79.17%. Conclusion: By adjusted the pediatric helical CT parameters basedon the of pediatric abdominal perimeter, exposure of patient to the hazards of radiation is reduced. (authors)

  2. Post-operative abdominal CT scanning in extrahepatic biliary atresia

    Energy Technology Data Exchange (ETDEWEB)

    Day, D L; Mulcahy, P F; Letourneau, J G; Dehner, L P

    1989-07-01

    A retrospective review of the abdominal CT scans of 26 children with extrahepatic biliary atresia was performed, and the results were correlated with available surgical and pathologic data. Associated congenital anomalies or acquired abnormalities were identified in these patients. Congenital anomalies included polysplenia, venous anomalies and bowel stenosis. Acquired abnormalities developed secondary to cirrhosis, portal hypertension, intrahepatic biliary duct dilatation, and hepatic ischemia. Despite frequent episodes of ascending cholangitis in these children, no hepatic abscesses were identified by CT or by pathologic examination. In conclusion, abdominal CT scanning of children with extrahepatic biliary atresia can define congenital and acquired abnormalities and provide important anatomic data for the surgeons before liver transplantation. (orig.).

  3. Is direct radiologist supervision of abdominal computed tomography (CT) scans necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Goh, V. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Halligan, S. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)]. E-mail: s.halligan@imperial.ac.uk; Anderson, J.M. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Hugill, J. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom); Leonard, A. [Department of Clinical Radiology, Northwick Park and St Mark' s Hospitals, Harrow (United Kingdom)

    2005-07-01

    AIM: To determine the effect of direct radiological supervision of patients attending for abdominal CT by assessing the frequency of protocol alteration subsequent to radiologist review of the images obtained. MATERIALS AND METHODS: A prospective questionnaire-based observational study was performed of 187 consecutive patients undergoing abdominal CT. The CT protocol was determined by a radiologist in advance, with reference to the request form. Any subsequent change in the prescribed study that was contingent on radiologist review of the images obtained was documented on the questionnaire. Comparison was made with a second (control) group of 100 patients undergoing cranial CT. RESULTS: A protocol change was undertaken following radiologist review of the CT images of 17 (9%) of the group undergoing abdominal CT, compared with 14 (14%) of the group undergoing cranial CT. In the abdominal CT group, further scanning was performed for lesion characterization, to guide a subsequent interventional procedure, because of inadequate anatomical coverage or to evaluate an unexpected lung tumour. There was no significant difference in proportions between the two groups (p=0.23). CONCLUSION: When abdominal and cranial CT studies were compared, there was no significant difference in the proportion of studies requiring a change in the prescribed protocol following radiologist review of the images obtained. There was no evidence to suggest that abdominal CT was any less suited to protocol.

  4. Optimization of individualized abdominal scan protocol with 64-slice CT scanner

    International Nuclear Information System (INIS)

    Hu Minxia; Zhao Xinming; Song Junfeng; Zhou Chunwu

    2012-01-01

    Objective: To explore an individualized abdominal scan protocol with a 64-slice CT scanner. Methods: From Sep. 2010 to Nov. 2010, one hundred consecutive patients, who underwent twice non-contrast-enhanced abdominal CT scans within 3 months, were enrolled in this study. For each patient, the tube current of 274 eff. mAs and 207 eff. mAs were applied respectively in the first and second abdominal scan. The imaging qualities of the two scans were evaluated retrospectively by 3 reviewers. All the individual variants,including height, weight, body mass index (BMI), the maximum transverse diameter, the anteroposterior diameter and the average maximum diameter of abdomen were recorded. A five-point scale was used for grading the image noise of eight organs, including abdominal aorta, portal vein, liver, spleen, gallbladder, pancreas, renal cortex and renal medulla. Diagnostic acceptability of CT images at three anatomic levels,including porta hepatis, pancreas and the upper pole of renal, was also evaluated by using a five-point scale. The noise value of abdominal aorta was defined as the standard deviation (SD) of CT values of aorta at the level of porta hepatis. Scatter diagram and Pearson correlation analysis were used for evaluating the linear relationship between the individual variants and the noise value of abdominal aorta, and multivariate linear regression analysis was used for evaluating the relevance between the individual variants and the noise value of aorta. Results: In this patients group, the average height was (164.6 ± 7.5) cm,the average weight was (64.3 ± 11.0) kg, the BMI was (23.7 ±3.3) kg/m 2 , the maximum transverse diameter of abdomen was (29.8 ± 2.3) cm, the anteroposterior diameter of abdomen was (23.1 ± 2.9) cm, and the average maximum diameter of abdomen was (26.5 ± 2.5) cm. Pearson correlation analysis showed significant positive linear correlation between the noise value of abdominal aorta (1 1.7 ± 3.0) and patients' weight (r=0

  5. Differential Aging Signals in Abdominal CT Scans.

    Science.gov (United States)

    Orlov, Nikita V; Makrogiannis, Sokratis; Ferrucci, Luigi; Goldberg, Ilya G

    2017-12-01

    Changes in the composition of body tissues are major aging phenotypes, but they have been difficult to study in depth. Here we describe age-related change in abdominal tissues observable in computed tomography (CT) scans. We used pattern recognition and machine learning to detect and quantify these changes in a model-agnostic fashion. CT scans of abdominal L4 sections were obtained from Baltimore Longitudinal Study of Aging (BLSA) participants. Age-related change in the constituent tissues were determined by training machine classifiers to differentiate age groups within male and female strata ("Younger" at 50-70 years old vs "Older" at 80-99 years old). The accuracy achieved by the classifiers in differentiating the age cohorts was used as a surrogate measure of the aging signal in the different tissues. The highest accuracy for discriminating age differences was 0.76 and 0.72 for males and females, respectively. The classification accuracy was 0.79 and 0.71 for adipose tissue, 0.70 and 0.68 for soft tissue, and 0.65 and 0.64 for bone. Using image data from a large sample of well-characterized pool of participants dispersed over a wide age range, we explored age-related differences in gross morphology and texture of abdominal tissues. This technology is advantageous for tracking effects of biological aging and predicting adverse outcomes when compared to the traditional use of specific molecular biomarkers. Application of pattern recognition and machine learning as a tool for analyzing medical images may provide much needed insight into tissue changes occurring with aging and, further, connect these changes with their metabolic and functional consequences. Published by Elsevier Inc.

  6. Dynamic CT in the abdominal organ, 1

    International Nuclear Information System (INIS)

    Fukuda, Kunihiko

    1980-01-01

    By utilizing a 4.5-second CT (computed tomography) scanner which allows sequential scans the changes of the iodine concentration in abdominal organs can be observed as dynamics reflected in CT number. The abdominal dynamic CT was performed as following method. After performing the preliminary scan 50ml of 60% meglumine iothalamate was rapidly injected intravenously by hands. The sequential scanning was initiated when a half dose of contrast medium was injected. In completion of the 4 sequential scans under arrested respiration the conventional post contrast scanning was performed. The analysis of 112 cases dynamically studied by CT came to the following conclusion. CT number of the abdominal aorta was greatest on the 1st or 2nd scan of the sequential scans (7.5 - 20.5 seconds after initiation of injection). Following this peak formation, CT number of the abdominal aorta declined rapidly due to both prompt diffusion of contrast medium into the extravascular space and dilution by the intravascular fluid. Iodine concentration of the abdominal aorta during the peak period was calculated as 11.3 mg/ml by the present method, being theoretically sufficient for delineation of the vessels smaller than medium size. In the patients with impaired renal function, several characteristic patterns were noted on the dynamics of contrast medium within the abdominal organs. The abdominal dynamic CT was felt to be promissing for evaluation of the renal function. (author)

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... CT scan, an experienced radiologist can diagnose many causes of abdominal pain or injury from trauma with ...

  8. Evaluation of abdominal CT in the initial treatment of abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishii, Takashi; Kuwata, Katsuya; Yoneyama, Chihiro; Kitamura, Kazuya; Sasaki, Yoshifumi; Kamachi, Masahiro; Nishiguchi, Hiroyasu.

    1986-01-01

    During the last four years 102 patients with abdominal trauma were examined by CT for preoperative evaluation in our hospital. In 35 patients (34 %), the CT scans revealed no abnormal findings. They were all managed conservatively except for one case of perforated small bowel. In 67 patients (66 %) CT revealed evidences of substantial abdominal or retroperitoneal trauma. In 30 of them CT findings were confirmed by surgery. Hepatic injury is usually easily recognized by CT. CT is also useful for the detection of renal or splenic injuries. The majority of those parenchymatous organ injuries were successfully managed with conservative therapy, despite apparent traumatic lesions revealed by CT. Repeat CT scans is proved to be very useful to follow the changes of these traumatic lesions. In conclusion, application of abdominal CT is extremely useful for the initial decision making in treatment of patients with abdominal trauma and for the follow-up observation of injured lesions. (author)

  9. Intra-abdominal fat area measurement using chest CT data

    International Nuclear Information System (INIS)

    Moriya, Hiroshi; Midorikawa, Shigeo; Hashimoto, Kouji; Ishii, Akira; Saitou, Kumi; Andou, Tomonori; Kitamura, Naoko; Sakuma, Koutarou

    2007-01-01

    Intra-abdominal fat obesity, which is linked with the metabolic syndrome, is usually characterized by measuring intra-abdominal fat area at the umbilical level of abdominal CT scan. In recent year, the chances of chest CT scanning are increased, as lung cancer screening survey or individual medical examination. Thus, we presented a method of measuring the areas of intra-abdominal fat and subcutaneous fat at the lower slice of chest CT scan. Fat areas found with this method were significantly correlated with those obtained at the umbilical level. (author)

  10. Relationship between sudden natural death and abdominal fat evaluated on postmortem CT scans.

    Science.gov (United States)

    Kaichi, Y; Sakane, H; Higashibori, H; Honda, Y; Tatsugami, F; Baba, Y; Iida, M; Awai, K

    2017-06-01

    This study examined the association between sudden natural death and abdominal fat using postmortem computed tomography (CT) scans. Postmortem CT images at the umbilical level of 241 subjects were used to measure abdominal areas of subcutaneous- and visceral fat, the rate of visceral fat and the waist circumference. Of the study subjects, 174 died of sudden natural death (130 men and 44 women), and 67 died of different causes (46 men and 21 women). All were between 40 and 75 years of age. Logistic regression analysis was performed to identify independent abdominal parameters associated with sudden natural death. By univariate analysis, the areas of subcutaneous and visceral fat were significantly larger in sudden natural death than who died of different causes (subcutaneous fat, odds ratio [OR] = 1.004, 95% confidence interval [CI] = 1.000-1.007, p  = 0.03; visceral fat, OR = 1.008, 95% CI = 1.003-1.013, p  fat was an independent factor associated with the risk of sudden natural death (OR = 1.008, 95% CI = 1.002-1.015, p  = 0.02). Postmortem CT revealed that sudden natural death was related to abdominal fat deposits.

  11. CT evaluation of abdominal trauma

    International Nuclear Information System (INIS)

    Huang Ruiting

    2004-01-01

    Objective: An evaluation of CT diagnosis of abdominal trauma. Methods: CT appearance of abdominal trauma was analyzed retrospectively in 95 cases. thirty-three patients were cured by operation, and the other 59 patients received conservative treatment. Fifty-one patients out of 59 were seen healed or improved by a follow up CT scan after the conservative treatment. Results: The study included: 31 cases of splenic contusion, accompanying with hemoperitoneum in 25 cases; 3 cases of hepatic laceration; 33 cases of liver and spleen compound trauma accompanying with hemoperitoneum; 18 cases of renal contusion, with subcapsular hemorrhage in 12 cases; 4 cases of midriff colic; 3 cases of mesentery breach; 3 cases of digestive tract perforation. Conclusion: CT is sensitive and precise in evaluating abdominal trauma, providing important information for treatment. (author)

  12. CT diagnosis of unsuspected pneumothorax after blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Wall, S.D. (Univ. of California, San Francisco); Federle, M.P.; Jeffrey, R.B.; Brett, C.M.

    1983-11-01

    Review of abdominal CT scans for evaluation of blunt abdominal trauma yielded 35 cases of pneumothorax, 10 of which had not been diagnosed before CT by clinical examination of plain radiographs. Of the 10 cases initially diagnosed on CT, seven required tube thoracostomy for treatment of the pneumothorax. CT detection of pneumothorax is especially important if mechanical assisted ventilation or general anesthesia is used. Demonstration of pneumothorax requires viewing CT scans of the upper abdomen (lower thorax) at lung windows in addition to the usual soft-tissue windows.

  13. CT diagnosis of unsuspected pneumothorax after blunt abdominal trauma

    International Nuclear Information System (INIS)

    Wall, S.D.; Federle, M.P.; Jeffrey, R.B.; Brett, C.M.

    1983-01-01

    Review of abdominal CT scans for evaluation of blunt abdominal trauma yielded 35 cases of pneumothorax, 10 of which had not been diagnosed before CT by clinical examination of plain radiographs. Of the 10 cases initially diagnosed on CT, seven required tube thoracostomy for treatment of the pneumothorax. CT detection of pneumothorax is especially important if mechanical assisted ventilation or general anesthesia is used. Demonstration of pneumothorax requires viewing CT scans of the upper abdomen (lower thorax) at lung windows in addition to the usual soft-tissue windows

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... often used to determine the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. ... help diagnose the cause of abdominal or pelvic pain and diseases of the internal organs, small bowel ...

  15. Value of a step-up diagnosis plan: CRP and CT-scan to diagnose and manage postoperative complications after major abdominal surgery

    Directory of Open Access Journals (Sweden)

    Jennifer Straatman

    2014-12-01

    Full Text Available Postoperative complications frequently follow major abdominal surgery and are associated with increased morbidity and mortality. Early diagnosis and treatment of complications is associated with improved patient outcome. In this study we assessed the value of a step-up diagnosis plan by C-reactive protein and CT-scan (computed tomography-scan imaging for detection of postoperative complications following major abdominal surgery. An observational cohort study was conducted of 399 consecutive patients undergoing major abdominal surgery between January 2009 and January 2011. Indication for operation, type of surgery, postoperative morbidity, complications according to the Clavien-Dindo classification and mortality were recorded. Clinical parameters were recorded until 14 days postoperatively or until discharge. Regular C-reactive protein (CPR measurements in peripheral blood and on indication -enhanced CT-scans were performed. Eighty-three out of 399 (20.6 % patients developed a major complication in the postoperative course after a median of seven days (IQR 4-9 days. One hundred and thirty two patients received additional examination consisting of enhanced CT-scan imaging, and treatment by surgical reintervention or intensive care observation. CRP levels were significantly higher in patients with postoperative complications. On the second postoperative day CRP levels were on average 197.4 mg/L in the uncomplicated group, 220.9 mg/L in patients with a minor complication and 280.1 mg/L in patients with major complications (p < 0,001. CT-scan imaging showed a sensitivity of 91.7 % and specificity of 100 % in diagnosis of major complications. Based on clinical deterioration and the increase of CRP, an additional enhanced CT-scan offered clear discrimination between patients with major abdominal complications and uncomplicated patients. Adequate treatment could then be accomplished.

  16. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation

    International Nuclear Information System (INIS)

    Snow, Aisling; Milliren, Carly E.; Graham, Dionne A.; Callahan, Michael J.; MacDougall, Robert D.; Robertson, Richard L.; Taylor, George A.

    2017-01-01

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children's hospital admission reports were rated higher

  17. Focused abdominal CT scan for acute appendicitis in children: can it help in need

    International Nuclear Information System (INIS)

    Akhtar, W.; Ali, S.; Arshad, M.; Nadeem, M.

    2011-01-01

    Objective: To evaluate the focused abdominal CT scan [FACT] in clinically equivocal cases of acute appendicitis in paediatric population. Methods: A cross-sectional study was conducted at the Radiology Department of Aga Khan Hospital, from August 2007 to November 2008. A total of 84 patients (42 males and 42 females) with clinically equivocal signs and symptoms of acute appendicitis referred to radiology department for CT evaluation were studied. CT findings were compared with histopathology and clinical follow-up. Results: The sensitivity of focused CT for acute appendicitis was 91%; specificity was 69% and accuracy of 76% while PPV and NPV were 58%, 94% respectively. Conclusion: Focused unenhanced CT is a quick, accurate and non invasive modality for the assessment of clinically equivocal cases of acute appendicitis for ruling out patients and reducing negative appendectomies. (author)

  18. Abdominal computed tomography scan as a screening tool in blunt trauma

    International Nuclear Information System (INIS)

    Brasel, K.J.; Borgstrom, D.C.; Kolewe, K.A.

    1997-01-01

    Background. One of the most difficult problems in blunt trauma is evaluation for potential intraabdominal injury. Admission for serial abdominal exams remains the standard of care after intraabdominal injury has been initially excluded. We hypothesized a normal abdominal computed tomography (CT) scan in a subgroup of minimally injured patients would obviate admission for serial abdominal examinations, allowing safe discharge from the emergency department (ED). Methods. We reviewed our blunt trauma experience with patients admitted solely for serial abdominal examinations after a normal CT. Patients were identified from the trauma registry at a Level 1 trauma center from July 1991 through June 1995. Patients with abnormal CTs, extra-abdominal injuries necessitating admission, hemodynamic abnormalities, a Glasgow Coma Scale less than 13, or injury severity scores (ISSs) greater than 15 were excluded. Records of 238 patients remained; we reviewed them to determine the presence of missed abdominal injury. Results. None of the 238 patients had a missed abdominal injury. Average ISS of these patients was 3.2 (range, 0 to 10). Discharging these patients from the ED would result in a yearly cost savings of $32,874 to our medical system. Conclusions. Abdominal CT scan is a safe and cost-effective screening tool in patients with blunt trauma. A normal CT scan in minimally injured patients allows safe discharge from the ED. (authors)

  19. Abdominal aspergillosis: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Suk Keu, E-mail: pagoda20@hanmail.net [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Hye Jin, E-mail: kimhyejin@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Byun, Jae Ho, E-mail: jhbyun@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Ah Young, E-mail: aykim@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Lee, Moon-Gyu, E-mail: mglee@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Ha, Hyun Kwon, E-mail: hkha@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2011-03-15

    Objective: In order to retrospectively evaluate the CT findings of abdominal aspergillosis in immunocompromised patients. Materials and methods: CT scans were reviewed with regard to the sites, number, morphologic appearance, attenuation, and the contrast enhancement patterns of the lesions in six patients (5 women, 1 man; mean age, 43.4 years; range, 23-59 years) with pathologically proved abdominal aspergillosis by two gastrointestinal radiologists in consensus. Medical records were also reviewed to determine each patient's clinical status and outcome. Results: All patients were immunocompromised state: 4 patients received immunosuppressive therapy for solid organ transplantation and 2 patients received chemotherapy for acute myeloid leukemia. Aspergillosis involved blood vessels (n = 3), liver (n = 2), spleen (n = 2), gastrointestinal tract (n = 2), native kidney (n = 1), transplanted kidney (n = 1), peritoneum (n = 1), and retroperitoneum (n = 1). CT demonstrated solid organ or bowel infarction or perforation secondary to vascular thrombosis or pseudoaneurysm, multiple low-attenuating lesions of solid organs presenting as abscesses, concentric bowel wall thickening mimicking typhlitis, or diffuse or nodular infiltration of the peritoneum and retroperitoneum. Conclusion: Familiarity with findings commonly presenting as angioinvasive features or abscesses on CT, may facilitate the diagnosis of rare and fatal abdominal aspergillosis.

  20. The Use of CT Scan in Hemodynamically Stable Children with Blunt Abdominal Trauma : Look before You Leap

    NARCIS (Netherlands)

    Nellensteijn, David R.; Greuter, Marcel J.; el Moumni, Moustafa; Hulscher, Jan B.

    We set out to determine the diagnostic value of computed tomographic (CT) scans in relation to the radiation dose, tumor incidence, and tumor mortality by radiation for hemodynamically stable pediatric patients with blunt abdominal injury. We focused on the changes in management because of new

  1. Comparative analysis of the radiation shield effect in an abdominal CT scan

    International Nuclear Information System (INIS)

    Kim, Seon-Chil; Kim, Young-Jae; Lee, Joon-Seok; Dong, Kyung-Rae; Chung, Woon-Kwan; Lim, Chang-Seon

    2014-01-01

    This study measured and compared the dose on the eyeballs and the thyroid with and without the use of a shield by applying the abdominal examination protocol used in an actual examination to a 64-channel computed tomography (CT) scan. A dummy phantom manufactured from acryl was used to measure the dose to the eyeballs and the thyroid of a patient during a thoraco-abdominal CT scan. The dose was measured using three dosimeters (optically-stimulated luminescence dosimeter (OSLD), thermoluminescence dosimeter (TLD) and photoluminescence dosimeter (PLD)) attached to the surfaces of three parts (left and right eyeballs and thyroid) in a phantom with and without the use of a shield for the eyeballs and the thyroid. Two types of shields (1-mm barium shielding sheet and 1-mm tungsten shielding sheet) were used for the measurements. The goggles and the lead shield, which are normally used in clinical practice, were used to compare the shield ratios of the shields. According to the results of the measurements made by using the OSLD, the shield ratios of the barium and the tungsten sheets were in the range of 34 - 36%. The measurements made by using the TLD showed that the shield ratio of the barium sheet was 6.25% higher than that of the tungsten sheet. When the PLD was used for the measurement, the shield ratio of the barium sheet was 33.34%, which was equivalent to that of the tungsten sheet. These results confirmed that the cheap barium sheet had a better shielding effect than the expensive tungsten sheet.

  2. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Aisling [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Our Lady' s Children' s Hospital, Department of Radiology, Dublin (Ireland); Milliren, Carly E.; Graham, Dionne A. [Boston Children' s Hospital, Program for Patient Safety and Quality, Boston, MA (United States); Callahan, Michael J.; MacDougall, Robert D.; Robertson, Richard L.; Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States)

    2017-04-15

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children

  3. CT of hemodynamically unstable abdominal trauma

    International Nuclear Information System (INIS)

    Petridis, A.; Pilavaki, M.; Vafiadis, E.; Palladas, P.; Finitsis, S.; Drevelegas, A.

    1999-01-01

    This article is an appraisal of the use of CT in the management of patients with unstable abdominal trauma. We examined 41 patients with abdominal trauma using noncontrast dynamic CT. In 17 patients a postcontrast dynamic CT was also carried out. On CT, 25 patients had hemoperitoneum. Thirteen patients had splenic, 12 hepatic, 6 pancreatic, 8 bowel and mesenteric, 12 renal and 2 vascular injuries. Seven patients had retroperitoneal and 2 patients adrenal hematomas. All but five lesions (three renal, one pancreatic, and one splenic) were hypodense when CT was performed earlier than 8 h following the injury. Postcontrast studies (n = 17), revealed 4 splenic, 3 hepatic, 1 pancreatic, 3 renal, and 2 bowel and mesenteric injuries beyond what was found on noncontrast CT. Surgical confirmation (n = 21) was obtained in 81.81 % of splenic, 66.66 % of hepatic, 83.33 % of pancreatic, 100 % of renal, 100 % of retroperitoneal, and 85.71 % of bowel and mesenteric injuries. The majority of false diagnoses was obtained with noncontrast studies. Computed tomography is a remarkable method for evaluation and management of patients with hemodynamically unstable abdominal trauma, but only if it is revealed in the emergency room. Contrast injection, when it could be done, revealed lesions that were not suspected on initial plain scans. (orig.)

  4. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  5. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  6. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Yang, K; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

  7. CT of hemodynamically unstable abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Petridis, A.; Pilavaki, M.; Vafiadis, E.; Palladas, P.; Finitsis, S.; Drevelegas, A. [Department of Radiology, General Hospital ``G. Papanikolaou,`` Thessaloniki (Greece)

    1999-03-01

    This article is an appraisal of the use of CT in the management of patients with unstable abdominal trauma. We examined 41 patients with abdominal trauma using noncontrast dynamic CT. In 17 patients a postcontrast dynamic CT was also carried out. On CT, 25 patients had hemoperitoneum. Thirteen patients had splenic, 12 hepatic, 6 pancreatic, 8 bowel and mesenteric, 12 renal and 2 vascular injuries. Seven patients had retroperitoneal and 2 patients adrenal hematomas. All but five lesions (three renal, one pancreatic, and one splenic) were hypodense when CT was performed earlier than 8 h following the injury. Postcontrast studies (n = 17), revealed 4 splenic, 3 hepatic, 1 pancreatic, 3 renal, and 2 bowel and mesenteric injuries beyond what was found on noncontrast CT. Surgical confirmation (n = 21) was obtained in 81.81 % of splenic, 66.66 % of hepatic, 83.33 % of pancreatic, 100 % of renal, 100 % of retroperitoneal, and 85.71 % of bowel and mesenteric injuries. The majority of false diagnoses was obtained with noncontrast studies. Computed tomography is a remarkable method for evaluation and management of patients with hemodynamically unstable abdominal trauma, but only if it is revealed in the emergency room. Contrast injection, when it could be done, revealed lesions that were not suspected on initial plain scans. (orig.) With 6 figs., 5 tabs., 20 refs.

  8. Abdominal lymphadenopathy in tuberculosis and lymphoma: Differentiation with CT

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Choi, Byung Ihn; Han, Joon Koo; Han, Man Chung; Song, Chi Sung; Yang, Seoung Oh

    1993-01-01

    Tuberculosis and lymphoma, these 2 dieases can present with lymphadenopathy in anywhere of the body. Therefore differentiation of tuberculosis from lymphoma is often difficult. CT scans of 17 patients with tuberculosis and 23 patients with lymphoma were retrospectively reviewed to evaluate the efficacy of CT scans in differentating adenopathy between tuberculosis and lymphoma. All the patients underwent abdominal CT scans with contrast enhancement before treatment. The size, internal architecture, distribution of lymph nodes, and associated findings on CT scans were analyzed. As compared with lymphoma, tuberculous lymphadenopathy showed 1) female preponderance (65%), 2) predilection for percolative lymph nodes (47%), 3) internal low attenuation in lymph nodes (82%), 4) cold abscess formation (24%). Characteristics of lymphoma on CT scans include 1) male preponderance (78%), 2) conglomeration of lymph nodes (39%), 3) homogeneous internal lymph node structure (83%). These results suggest that evaluation of the cahracteristics of lymphadenopathy on CT scans is helpful for differentiating between tuberculousis and lymphoma

  9. Abdominal organ motion measured using 4D CT

    International Nuclear Information System (INIS)

    Brandner, Edward D.; Wu, Andrew; Chen, Hungcheng; Heron, Dwight; Kalnicki, Shalom; Komanduri, Krishna; Gerszten, Kristina; Burton, Steve; Ahmed, Irfan; Shou, Zhenyu

    2006-01-01

    Purpose: To measure respiration-induced abdominal organ motion using four-dimensional computed tomography (4D CT) scanning and to examine the organ paths. Methods and Materials: During 4D CT scanning, consecutive CT images are acquired of the patient at each couch position. Simultaneously, the patient's respiratory pattern is recorded using an external marker block taped to the patient's abdomen. This pattern is used to retrospectively organize the CT images into multiple three-dimensional images, each representing one breathing phase. These images are analyzed to measure organ motion between each phase. The displacement from end expiration is compared to a displacement limit that represents acceptable dosimetric results (5 mm). Results: The organs measured in 13 patients were the liver, spleen, and left and right kidneys. Their average superior to inferior absolute displacements were 1.3 cm for the liver, 1.3 cm for the spleen, 1.1 cm for the left kidney, and 1.3 cm for the right kidney. Although the organ paths varied among patients, 5 mm of superior to inferior displacement from end expiration resulted in less than 5 mm of displacement in the other directions for 41 of 43 organs measured. Conclusions: Four-dimensional CT scanning can accurately measure abdominal organ motion throughout respiration. This information may result in greater organ sparing and planning target volume coverage

  10. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  11. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  12. A reappraisal of adult thoracic and abdominal surface anatomy via CT scan in Chinese population.

    Science.gov (United States)

    Shen, Xin-Hua; Su, Bai-Yan; Liu, Jing-Juan; Zhang, Gu-Muyang; Xue, Hua-Dan; Jin, Zheng-Yu; Mirjalili, S Ali; Ma, Chao

    2016-03-01

    Accurate surface anatomy is essential for safe clinical practice. There are numerous inconsistencies in clinically important surface markings among and within contemporary anatomical reference texts. The aim of this study was to investigate key thoracic and abdominal surface anatomy landmarks in living Chinese adults using computed tomography (CT). A total of 100 thoracic and 100 abdominal CT scans were examined. Our results indicated that the following key surface landmarks differed from current commonly-accepted descriptions: the positions of the tracheal bifurcation, azygos vein termination, and pulmonary trunk bifurcation (all below the plane of the sternal angle at vertebral level T5-T6 in most individuals); the superior vena cava formation and junction with the right atrium (most often behind the 1st and 4th intercostal spaces, respectively); and the level at which the inferior vena cava and esophagus traverse the diaphragm (T10 and T11, respectively). The renal arteries were most commonly at L1; the midpoint of the renal hila was most frequently at L2; the 11th rib was posterior to the left kidney in only 29% of scans; and the spleen was most frequently located between the 10th and 12th ribs. A number of significant sex- and age-related differences were noted. The Chinese population was also compared with western populations on the basis of published reports. Reappraisal of surface anatomy using modern imaging tools in vivo will provide both quantitative and qualitative evidence to facilitate the clinical application of these key surface landmarks. © 2015 Wiley Periodicals, Inc.

  13. ORIGINAL ARTICLE ORIG ORIG CT for upper abdominal pathology ...

    African Journals Online (AJOL)

    CT scan contributes to the final diagnosis in organ-specific upper- abdominal ..... planes to encase the celiac axis and superior mesenteric artery, the superior ... men, and possibly pelvis, to evaluate for extrahepatic disease.15 In one.

  14. Frequency and significance of thoracic injuries detected on abdominal trauma CT scans

    International Nuclear Information System (INIS)

    Hareli, G.S.; Rhea, J.T.; Novelline, R.A.; Lawrason, N.; Sacknoff, R.; Oser, A.

    1987-01-01

    The authors have noted that in multiple trauma patients chest injuries inapparent on initial chest radiographs may be detected at abdominal CT. In an ongoing series of 112 patients to date, 50 chest injuries were detected in 33 patients (29%). The injuries included 15 bilateral hemothoraces, seven unilateral hemothoraces, seven posttraumatic atrelectasis, seven lung contusions, five pneumothoraces, four rib factures, two thoracic spine fractures, two chest wall emphysema, and one mediastinal emphysema. In 24 of the 33 patients (72%) the injury was not seen on the initial chest radiographs; in seven patients treatment of the chest injury was required. The authors have included screening cuts of the middle and upper chest as part of their abdominal CT protocol

  15. Postmortem abdominal CT: Assessing normal cadaveric modifications and pathological processes

    International Nuclear Information System (INIS)

    Charlier, P.; Carlier, R.; Roffi, F.; Ezra, J.; Chaillot, P.F.; Duchat, F.; Huynh-Charlier, I.; Lorin de la Grandmaison, G.

    2012-01-01

    Purpose: To investigate the interest of postmortem non-enhanced computer tomography (CT) for abdominal lesions in a forensic context of suspicions death and to list the different radiological cadaveric modifications occurring normally at abdominal stage, which must be known by non forensic radiologists in case of any postmortem exam. Materials and methods: 30 cadavers have been submitted to a body CT-scan without injection of contrast material. CT exams were reviewed by two independent radiologists and radiological findings were compared with forensic autopsy data. Results: False positive CT findings included physiological postmortem transudates misdiagnosed with intra-abdominal bleedings, and putrefaction gas misdiagnosed with gas embolism, aeroporty, aerobily, digestive parietal pneumatosis. Incidentalomas without any role in death process were also reported. False negative CT findings included small contusions, vascular thromboses, acute infarcts foci, non radio-opaque foreign bodies. Normal cadaveric modifications were due to livor mortis and putrefaction, and are seen quickly (some hours) after death. Conclusion: The non forensic radiologist should be familiar with the normal abdominal postmortem features in order to avoid misdiagnoses, and detect informative lesions which can help and guide the forensic practitioner or the clinical physician.

  16. CT angiography. Abdominal CT using intravenous aortography for contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, J; Nakauma, Y; Egawa, J; Kawamura, M [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    1980-04-01

    To obtain imaging effects close to those of abdominal aortography and investigate a technique with little invasion to patients, intravenous aortography was applied to contrast enhancement (CE) in abdominal CT, and its usefulness was discussed. Intravenous aortography could clearly visualize lesions with rich neovascularity such as hepatocellular carcinoma and renal cell carcinoma. Differing from a drip infusion method, this method has complexities in its technique that contrast medium is injected at once, blood circulation time which is represented by the time between the injection and the time when the patients feel bitterness (10 - 12 seconds) must be measured before CE, and scanning begins 2 seconds before the patients feel bitterness. However, the invasion to patients due to this method is slight, and the capacity of this method to visualize neovascularity is superior to CE by a drip infusion method. Therefore, qualitative diagnosis by CT will be improved by using this method together with a drip infusion method.

  17. CT diagnosis of abdominal lymph node metastases in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Nakamura, H; Choi, S; Morimoto, K; Kawamoto, S; Hori, S; Tokunaga, K; Yoskioka, H; Kuroda, C

    1985-08-01

    CT scanning is useful for diagnosing abdominal lymph node metastasis. Using this technique, histologically confirmed abdominal lymph node metastases were detected in nine of 49 patients (33 autopsy cases and 16 laparotomy cases) with hepatocellular carcinoma (hepatoma). Among the 49 patients, three had periportal (6.1%), six peripancreatic (12.2.%) and six para-aortic adenopathies (12.2%). Two of the patients had adenopathy at all three sites. Retrospectively, CT detected two periportal, four peripancreatic and all six para-aortic adenopathies. Most of the hepatomas with adenopathy showed infiltrative growth; tumour thrombosis of the portal vein was a common complication.

  18. Postoperative findings following the Whipple procedure : determination of prevalence and morphologic abdominal CT features

    NARCIS (Netherlands)

    Mortele, KJ; Lemmerling, M; de Hemptinne, B; De Vos, M; De Bock, G; Kunnen, M

    2000-01-01

    This study was conducted to determine characteristic CT findings following the Whipple procedure and to evaluate the usefulness of CT in re-dieting tumor recurrence. Eighty-four postoperative abdominal CT scans and medical records of 43 patients were retrospectively reviewed. Perioperative

  19. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    Energy Technology Data Exchange (ETDEWEB)

    Sivit, C.J. [Department of Radiology, Rainbow Babies and Children' s Hospital of the University Hospitals of Cleveland and Case Western Reserve School of Medicine, 11100 Euclid Avenue, Cleveland, OH (United States)

    2000-02-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  20. Detection of active intraabdominal hemorrhage after blunt trauma: value of delayed CT scanning

    International Nuclear Information System (INIS)

    Sivit, C.J.

    2000-01-01

    Active hemorrhage is a rare finding at CT following blunt abdominal trauma. The time interval between IV contrast administration and scanning the abdomen may impact on the ability to visualize active hemorrhage at CT. We report a case of active hemorrhage associated with splenic injury that was identified only at delayed CT scanning. (orig.)

  1. Image mottle in abdominal CT.

    Science.gov (United States)

    Ende, J F; Huda, W; Ros, P R; Litwiller, A L

    1999-04-01

    To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

  2. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  3. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  4. Acute Appendagitis Presenting with Features of Appendicitis: Value of Abdominal CT Evaluation

    Directory of Open Access Journals (Sweden)

    Sukhpreet Dubb

    2008-05-01

    Full Text Available We report a case of acute appendagitis in a patient who presented initially with typical features of acute appendicitis. The diagnosis of acute appendagitis was made on pathognomonic signs on computed tomography (CT scan. Abdominal pain is a common surgical emergency. CT is not always done if there are clear features of acute appendicitis. The rare but important differential diagnosis of acute appendagitis must be borne in mind when dealing with patients with suspected acute appendicitis. A CT scan of the abdomen may avoid unnecessary surgery in these patients.

  5. A review of the benefits and rationale of viewing liver window settings for abdominal computed tomography scans

    International Nuclear Information System (INIS)

    Dang, Tan; Mandarano, Giovanni

    2006-01-01

    There have been many different opinions over the efficacy of routinely incorporating liver-window settings in abdominal computed tomography (CT) scans. As a result, different clinical centres have varying protocols for incorporating liver-windows for abdominal CT scans. This investigation aims to explore and determine whether various clinical centres throughout Victoria use liver-window settings selectively or routinely and their justification for doing so. An additional purpose is also to assess the benefits and rationale of liver-window settings in supplementing routine soft-tissue-windows for abdominal CT examinations by reviewing evidenced-based studies. Surveys were sent out to CT supervisors at various clinical centres, including private and public institutions. This achieved an overall response rate of 74 per cent. Results indicate that the majority of clinical centres throughout Victoria routinely incorporate liver-window settings for all abdominal CT examinations. Forty four per cent (11/25) of respondents stated that they utilise liver-window settings selectively for abdominal CT examinations. Most of these respondents (7/11 = 63 per cent) believed that soft-tissue-window settings alone are adequate to demonstrate hepatic lesions; particularly if intravenous contrast media is used and the liver is captured in the arterial, venous and/or delayed phases. The benefits and rationale of incorporating liver-window settings for all abdominal computed tomography scans has been questioned by two well noted studies in the United States. These evidence-based studies suggest that such additional settings do not offer further advantages in detecting hepatic disease, when compared to soft-tissue-windows alone. Review of the available literature provides additional evidence suggesting that the routine use of liver-window settings in conjunction with soft-tissue-windows offers no further advantages in the detection of hepatic diseases. This investigation found, however

  6. CT diagnosis of intraperitoneal bladder rupture with blunt abdominal trauma

    International Nuclear Information System (INIS)

    Kong Fanbin

    2000-01-01

    Objective: To evaluate CT examination in the diagnosis of intraperitoneal bladder rupture (IPBR) caused by blunt abdominal trauma. Methods: All CT and clinical data of 9 patients with IPBR were reviewed retrospectively. Results: IPBR was detected on CT scans in all 9 patients. CT findings of IPBR included low -attenuation free intraperitoneal fluid collections in the lateral paravesical fossae, the pericolic space, the culde-sac of the pelvis, Morison's pouch, the peri-hepatic space, the perisplenic space and interspace of bowel loops in 9 cases with a lower CT density compared with pure blood. The disruption of the bladder wall was located by CT scan in 5 cases: high-attenuation bladder wall with focal defect in 3 cases and a tear drop-like deformity of the bladder in 2 cases. Other CT findings supporting the diagnosis of IPBR included an underfilled bladder in 8 cases, bladder contusion in 4 cases, and blood clots within the bladder in 6 cases. Conclusion: The presence of intraperitoneal fluid with a CT density less than that of pure blood strongly suggests extravasated urine in the trauma. Intraperitoneal and extraperitoneal rupture can be distinguished based on location of extravasated urine seen on CT scans. The precise localization of the ruptured bladder wall may be demonstrated by CT scan, which is valuable for surgical treatment

  7. Determination of dosimetric quantities in pediatric abdominal computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Jornada, Tiago da Silva [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostipo por Imagem; Silva, Teogenes Augusto da, E-mail: silvata@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-09-15

    Objective: aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods: the study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results: No significant difference was observed in the values for weighted air kerma index (C{sub W}), but the differences were relevant in values for volumetric air kerma index (C{sub VOL}), air kerma-length product (P{sub KL,CT}) and effective dose. Conclusion: Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, P{sub KL,CT} and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. (author)

  8. Determination of dosimetric quantities in pediatric abdominal computed tomography scans*

    Science.gov (United States)

    Jornada, Tiago da Silva; da Silva, Teógenes Augusto

    2014-01-01

    Objective Aiming at contributing to the knowledge on doses in computed tomography (CT), this study has the objective of determining dosimetric quantities associated with pediatric abdominal CT scans, comparing the data with diagnostic reference levels (DRL). Materials and methods The study was developed with a Toshiba Asteion single-slice CT scanner and a GE BrightSpeed multi-slice CT unit in two hospitals. Measurements were performed with a pencil-type ionization chamber and a 16 cm-diameter polymethylmethacrylate trunk phantom. Results No significant difference was observed in the values for weighted air kerma index (CW), but the differences were relevant in values for volumetric air kerma index (CVOL), air kerma-length product (PKL,CT) and effective dose. Conclusion Only the CW values were lower than the DRL, suggesting that dose optimization might not be necessary. However, PKL,CT and effective dose values stressed that there still is room for reducing pediatric radiation doses. The present study emphasizes the importance of determining all dosimetric quantities associated with CT scans. PMID:25741103

  9. Dynamic CT in the abdominal organ, 2. Dynamics in the abdominal malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, K [Jikei Univ., Tokyo (Japan). School of Medicine

    1980-03-01

    The potential role of the abdominal dynamic CT in malignant tumors was evaluated. Among total of 112 cases dynamically studied included were, 22 cases of abdominal malignancies, renal cell carcinoma in 7, hepatocellular carcinoma in 7, metastatic liver tumor in 5, renal pelvic carcinoma in 2, and pancreatic cystadenocarcinoma in one. The results led to the following advantages of the abdominal dynamic CT over conventional CT. (1) The tumor thrombus and the lymphnode involvement could be better demonstrated. (2) The tumor vessels and the tumor stain could be depicted. (3) The extent of the tumor in the parenchyma could be better appreciated. The more invasive catheter angiography would likely to be replaced by the abdominal dynamic CT in the selected case.

  10. Abdominal imaging in AIDS patients

    International Nuclear Information System (INIS)

    Zhao Dawei; Wang Wei; Yuan Chunwang; Jia Cuiyu; Zhao Xuan; Zhang Tong; Ma Daqing

    2007-01-01

    Objective: To evaluate abdominal imaging in AIDS. Methods: The imaging examinations (including US, CT and MR) of 6 patients with AIDS associated abdominal foci were analysed retrospectively. All the cases were performed US, and CT scan, of which 4 performed enhanced CT scan and 1 with MR. Results: Abdominal tuberculosis were found in 4 patients, including abdominal lymph nodes tuberculosis (3 cases) and pancreatic tuberculosis (1 case). The imaging of lymph nodes tuberculosis typically showed enlarged peripheral tim enhancement with central low-attenuation on contrast-enhanced CT. Pancreatic tuberculosis demonstrated low-attenuation area in pancreatic head and slightly peripheral enhancement. Disseminated Kaposi's sarcoma was seen in 1 case: CT and MRI scan demonstrated tumour infiltrated along hepatic portal vein and bronchovascular bundles. Pelvic tumor was observed in 1 case: CT scan showed large mass with thick and irregular wall and central low attenuation liquefacient necrotic area in the pelvic cavity. Conclusion: The imaging findings of AIDS with abdominal foci is extraordinarily helpful to the diagnosis of such disease. Tissue biopsy is needed to confirm the diagnosis. (authors)

  11. Abdominal wall hernias: computed tomography findings

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Rosas, George de Queiroz; Mota, Marcos Alexandre; Akisue, Sandra R. Tsukada; Galvao Filho, Mario de Melo.

    2005-01-01

    Abdominal hernias are a common clinical problem Clinical diagnosis of abdominal hernias can sometimes be challenging, particularly in obese patients or patients with previous abdominal surgery. CT scan of the abdomen allows visualization of hernias and their contents and the differentiation from other masses of the abdominal wall such as tumors, hematomas and abscesses. Moreover, CT may identify complications such as incarceration, bowel obstruction, volvulus and strangulation. This study illustrates the CT scan findings observed in different types of abdominal wall hernias. (author)

  12. Value of abdominal CT in the emergency department for patients with abdominal pain

    International Nuclear Information System (INIS)

    Rosen, Max P.; Siewert, Bettina; Bromberg, Rebecca; Raptopoulos, Vassilios; Sands, Daniel Z.; Edlow, Jonathan

    2003-01-01

    The purpose of our study is to demonstrate the value of CT in the emergency department (ED) for patients with non-traumatic abdominal pain. Between August 1998 and April 1999, 536 consecutive patients with non-traumatic abdominal pain were entered into our study. Using a computer order entry system, physicians were asked to identify: (a) their most likely diagnosis; (b) their level of certainty in their diagnosis; (c) if they thought CT would be normal or abnormal; (d) their treatment plan (prior to knowledge of the CT results); and (e) their role in deciding to order CT. This information was correlated with each patient's post-CT diagnosis and subsequent management. Pre- and post-CT diagnoses were concordant in 200 of 536 (37%) patients. The physicians' certainty in the accuracy of their pre-CT diagnosis was less than high in 88% of patients. Prior to CT, the management plan included hospital admission for 402 patients. Following CT, only 312 patients were actually admitted; thus, the net impact of performing CT was to obviate the need for hospital admission in 90 of 536 (17%) of patients with abdominal pain. Prior to CT, 67 of 536 (13%) of all patients would have undergone immediate surgery; however, following CT only 25 (5%) actually required immediate surgery. Among patients with the four most common pre-CT diagnoses (appendicitis, abscess, diverticulitis, and urinary tract stones) CT had the greatest impact on hospital admission and surgical management for patients with suspected appendicitis. For patients with suspected appendicitis, CT reduced the hospital admission rate in 28% (26 of 91) of patients and changed the surgical management in 40% (39 of 91) of patients. Our study demonstrates the advantage of performing abdominal CT in the ED for patients with non-traumatic abdominal pain. (orig.)

  13. Proposed protocol for realization of abdominal CT in patients admitted to the emergency room for trauma in HSJD

    International Nuclear Information System (INIS)

    Quesada Cascante, Lizbeth

    2013-01-01

    A protocol is established for computed tomography in trauma patients treated in emergency of Hospital San Juan de Dios. A literature review is conducted on abdominal CT protocols in specialized databases. The criteria, scanning, parameters and delay time are established for realization of abdominal CT in patients with traumatic emergencies in HSJD. Taking the thickness of the sections, the thickness of the sections in reconstruction, the quantities of contrast and the speed of injection in patients, have been standardized for the realization of abdominal CT in HSJD. Computed tomography should be preferably performed of routine in portal phase and the late from 5 minutes in patients with abdominal trauma, contributing in this phase as much information regarding the extent of abdominal injury [es

  14. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  15. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  16. CT diagnosis of abdominal ectopic pheochromocytoma

    International Nuclear Information System (INIS)

    Zhang Yuping; Zhao Zhiying

    2010-01-01

    Objective: To discuss the value of CT in diagnosis of abdominal ectopic pheochromocytoma. Methods: CT findings of 5 cases surgically and pathologically proved with ectopic pheochromocytoma were retrospectively analyzed. Results: Soft tissue mass with light asymmetry enhancement was found between the abdominal aorta and the inferior vena ca-va in one case. 1 case was completely cystic with light enhancement of the cystwall located in front of the left side of the abdominal aorta. 1 case of large solid mass occurred between the renal hilum and the tail of pancreas, with irregular shape, unclear boundary, central necrosis, calcification and obviously enhancement at the solid part. 2 cases showed as oval soft lump with even density, moderate strengthening located before the abdominal aorta. Paroxysmal hypertension occurred in 3 cases and didn't in 2 cases. Hypertension happened in 1 case during the operation because of stimulation. Blood pressure appeared in 1 case during and after operation. Blood and urinary catecholamine increased significantly in 4 cases. Conclusion: Ectopic pheochromocytoma mainly located surround the abdominal aorta with diverse CT performance. It is helpful for diagnosing when finding a lesion locates at the specified sites combined with typical clinical presentation. CT can not only depict small tumor, but also can show the relationship with surrounding structure, and it provides important information for the operation and prognosis. (authors)

  17. Integrated circuit detector technology in abdominal CT: added value in obese patients.

    Science.gov (United States)

    Morsbach, Fabian; Bickelhaupt, Sebastian; Rätzer, Susan; Schmidt, Bernhard; Alkadhi, Hatem

    2014-02-01

    The purpose of this article was to assess the effect of an integrated circuit (IC) detector for abdominal CT on image quality. In the first study part, an abdominal phantom was scanned with various extension rings using a CT scanner equipped with a conventional discrete circuit (DC) detector and on the same scanner with an IC detector (120 kVp, 150 effective mAs, and 75 effective mAs). In the second study part, 20 patients were included who underwent abdominal CT both with the IC detector and previously at similar protocol parameters (120 kVp tube current-time product and 150 reference mAs using automated tube current modulation) with the DC detector. Images were reconstructed with filtered back projection. Image quality in the phantom was higher for images acquired with the IC compared with the DC detector. There was a gradually increasing noise reduction with increasing phantom sizes, with the highest (37% in the largest phantom) at 75 effective mAs (p < 0.001). In patients, noise was overall significantly (p = 0.025) reduced by 6.4% using the IC detector. Similar to the phantom, there was a gradual increase in noise reduction to 7.9% in patients with a body mass index of 25 kg/m(2) or lower (p = 0.008). Significant correlation was found in patients between noise and abdominal diameter in DC detector images (r = 0.604, p = 0.005), whereas no such correlation was found for the IC detector (r = 0.427, p = 0.060). Use of an IC detector in abdominal CT improves image quality and reduces image noise, particularly in overweight and obese patients. This noise reduction has the potential for dose reduction in abdominal CT.

  18. Distribution of pleural effusion associated with ascites on abdominal CT

    Energy Technology Data Exchange (ETDEWEB)

    Bae, In Young; Park, Chan Sup; Yeon, Jae Woo; Jeon, Yong Sun; Choi, Sung Kyu; Chung, Won Kyun [Inha Univ. Hospital, Songnam (Korea, Republic of)

    1997-04-01

    To determine through an analysis of the location of pleural effusion associated with ascites, as seen on abdominal CT scan, differences in the distribution of pleural effusion according to the etiology and distribution of ascites. We retrospectively evaluated 77 consecutive patients in whom abdominal CT scan revealed pleural effusion associated with ascites. Patients with history of surgery or trauma and those with clinically and radiologically diagnosed lung or pleural diseases were excluded. We compared the location of pleural effusion with the etiology and distribution of ascites. Forty-two patients were suffering from hepatobiliary diseases, mainly right dominant pleural effusion (26/42, 62%). Fourteen had intraperitoneal carcinomatosis with no significant difference between the frequency of right dominant (5/14, 36%) and of left dominant (6/14, 43%) pleural effusion. Eleven patients had pancreatic diseases, with mainly left dominant pleural effusion (6/11, 55%). Patients with right dominant ascites usually had right dominant pleural effusion (22/24, 92%) and those with left dominant ascites had left dominant pleural effusion (9/10, 90%). Ascites-associated pleural effusion correlated with the anatomical location of the etiology of ascites; its laterality was, in addition, usually the same as that of ascites.

  19. Distribution of pleural effusion associated with ascites on abdominal CT

    International Nuclear Information System (INIS)

    Bae, In Young; Park, Chan Sup; Yeon, Jae Woo; Jeon, Yong Sun; Choi, Sung Kyu; Chung, Won Kyun

    1997-01-01

    To determine through an analysis of the location of pleural effusion associated with ascites, as seen on abdominal CT scan, differences in the distribution of pleural effusion according to the etiology and distribution of ascites. We retrospectively evaluated 77 consecutive patients in whom abdominal CT scan revealed pleural effusion associated with ascites. Patients with history of surgery or trauma and those with clinically and radiologically diagnosed lung or pleural diseases were excluded. We compared the location of pleural effusion with the etiology and distribution of ascites. Forty-two patients were suffering from hepatobiliary diseases, mainly right dominant pleural effusion (26/42, 62%). Fourteen had intraperitoneal carcinomatosis with no significant difference between the frequency of right dominant (5/14, 36%) and of left dominant (6/14, 43%) pleural effusion. Eleven patients had pancreatic diseases, with mainly left dominant pleural effusion (6/11, 55%). Patients with right dominant ascites usually had right dominant pleural effusion (22/24, 92%) and those with left dominant ascites had left dominant pleural effusion (9/10, 90%). Ascites-associated pleural effusion correlated with the anatomical location of the etiology of ascites; its laterality was, in addition, usually the same as that of ascites

  20. Inter-observer agreement for abdominal CT in unselected patients with acute abdominal pain

    International Nuclear Information System (INIS)

    Randen, Adrienne van; Lameris, Wytze; Nio, C.Y.; Spijkerboer, Anje M.; Meier, Mark A.; Tutein Nolthenius, Charlotte; Smithuis, Frank; Stoker, Jaap; Bossuyt, Patrick M.; Boermeester, Marja A.

    2009-01-01

    The level of inter-observer agreement of abdominal computed tomography (CT) in unselected patients presenting with acute abdominal pain at the Emergency Department (ED) was evaluated. Two hundred consecutive patients with acute abdominal pain were prospectively included. Multi-slice CT was performed in all patients with intravenous contrast medium only. Three radiologists independently read all CT examinations. They recorded specific radiological features and a final diagnosis on a case record form. We calculated the proportion of agreement and kappa values, for overall, urgent and frequently occurring diagnoses. The mean age of the evaluated patients was 46 years (range 19-94), of which 54% were women. Overall agreement on diagnoses was good, with a median kappa of 0.66. Kappa values for specific urgent diagnoses were excellent, with median kappa values of 0.84, 0.90 and 0.81, for appendicitis, diverticulitis and bowel obstruction, respectively. Abdominal CT has good inter-observer agreement in unselected patients with acute abdominal pain at the ED, with excellent agreement for specific urgent diagnoses as diverticulitis and appendicitis. (orig.)

  1. Inter-observer agreement for abdominal CT in unselected patients with acute abdominal pain

    Energy Technology Data Exchange (ETDEWEB)

    Randen, Adrienne van [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Amsterdam (Netherlands); Lameris, Wytze [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Nio, C.Y.; Spijkerboer, Anje M.; Meier, Mark A.; Tutein Nolthenius, Charlotte; Smithuis, Frank; Stoker, Jaap [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Bossuyt, Patrick M. [University of Amsterdam, Department of Clinical Epidemiology, Biostatistics, and Bioinformatics, Academic Medical Center, Amsterdam (Netherlands); Boermeester, Marja A. [University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands)

    2009-06-15

    The level of inter-observer agreement of abdominal computed tomography (CT) in unselected patients presenting with acute abdominal pain at the Emergency Department (ED) was evaluated. Two hundred consecutive patients with acute abdominal pain were prospectively included. Multi-slice CT was performed in all patients with intravenous contrast medium only. Three radiologists independently read all CT examinations. They recorded specific radiological features and a final diagnosis on a case record form. We calculated the proportion of agreement and kappa values, for overall, urgent and frequently occurring diagnoses. The mean age of the evaluated patients was 46 years (range 19-94), of which 54% were women. Overall agreement on diagnoses was good, with a median kappa of 0.66. Kappa values for specific urgent diagnoses were excellent, with median kappa values of 0.84, 0.90 and 0.81, for appendicitis, diverticulitis and bowel obstruction, respectively. Abdominal CT has good inter-observer agreement in unselected patients with acute abdominal pain at the ED, with excellent agreement for specific urgent diagnoses as diverticulitis and appendicitis. (orig.)

  2. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    International Nuclear Information System (INIS)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice; Sebbane, Mustapha; Molinari, Nicolas; Riou, Bruno

    2017-01-01

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10 -6 ) and management (88.5% to 95.8%, p=2.6 x 10 -6 ) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  3. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice [CHU Lapeyronie, Department of Medical Imaging, Montpellier Cedex 5 (France); Sebbane, Mustapha [Department of Emergency Medicine, CHU Lapeyronie, Montpellier (France); Molinari, Nicolas [Department of Medical Information and Statistics, CHU Montpellier (France); Riou, Bruno [GH Pitie-Salpetriere, APHP, Department of Emergency Medicine and Surgery, Paris (France)

    2017-02-15

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10{sup -6}) and management (88.5% to 95.8%, p=2.6 x 10{sup -6}) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  4. Feasibility of F-18-FDG PET/CT scan in abdominopelvic regions

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2008-01-01

    F-18-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/CT scan, which simultaneously provides metabolic function and morphology on the same tomographic section, is being the key imaging modality for diagnosis and treatment strategy of makignancies in various organs. FDG PET/CT scanning of the whole body beneficially allows the assessment of primary tumor and regional lymph nodes, and distant metastases and co-existed benign/other malignant lesions, as ''one stop shopping'' fashion. This technique contributes to the selection of the optimal treatment in individual patients, and also can predict histopathologic response to treatment and postoperative/post chemo-radiation therapeutic prognosis. In this paper, we describe the fundamental knowledge required for accurate interpretation of FDG PET/CT scan, and review the utility of this technique for diagnosis and treatment strategy of makignancies in abdominal and pelvic regions. (author)

  5. Postoperative findings following the Whipple procedure: determination of prevalence and morphologic abdominal CT features

    Energy Technology Data Exchange (ETDEWEB)

    Mortele, K.J.; Lemmerling, M.; Bock, G. de; Kunnen, M. [Department of Radiology, University Hospital Gent (Belgium); Hemptinne, B. de [Department of Digestive Surgery, University Hospital Gent (Belgium); Vos, M. de [Department of Gastroenterology, University Hospital Gent (Belgium)

    2000-01-01

    This study was conducted to determine characteristic CT findings following the Whipple procedure and to evaluate the usefulness of CT in predicting tumor recurrence. Eighty-four postoperative abdominal CT scans and medical records of 43 patients were retrospectively reviewed. Perioperative histopathologic examinations revealed malignancy in 32 patients (74.4 %). Time interval between surgery and CT varied from 13 days to 6 years and 7 months. Common postoperative findings were unopacified anastomotic bowel loops in the porta hepatis (n = 69 scans), perivascular cuffing (n = 42 scans), pneumobilia (n = 40 scans), dilated intrahepatic bile ducts (n = 22 scans), reactive lymphadenopathy (n = 21 scans), and transient fluid collections (n = 20 scans). Postoperative complications were detected on 17 CT scans (20.2 %): generalized ascites (n = 8 patients), deep abscesses (n = 3 patients), wound abscess (n = 1 patient), pancreatitis (n = 1 patient), and pseudomembranous colitis (n = 1 patient). Tumor recurrence appeared in 15 patients (46.8 %) after a mean postoperative period of 11 months (1 month to 3 years): local (9 of 15), regional lymph nodes (9 of 15), and liver metastasis (8 of 15). Detection of generalized ascites more than 30 days after surgery was associated with tumor recurrence in 6 of 6 patients (100 %). Diffuse ascites (> 30 days after surgery) behaved as an early predictive sign of tumor recurrence. In our series CT accuracy for detecting recurrent tumor with CT was 93.5 %. No predilection site for disease recurrence could be determined. (orig.)

  6. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry.

    Science.gov (United States)

    Manios, G E; Mazonakis, M; Voulgaris, C; Karantanas, A; Damilakis, J

    2016-03-01

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95% limits of agreement were also acceptable (VAF: -16.5%, 16.1%; SAF: -10.8%, 10.7%) and the repeatability of stereology was good (VAF: CV = 4.5%, SAF: CV = 3.2%). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. Abdominal obesity is associated with increased risk of disease and mortality. Stereology may quantify visceral and subcutaneous abdominal fat accurately and consistently. The application of stereology to estimating abdominal volume fat reduces processing time. Stereology is an efficient alternative method for estimating abdominal fat volume.

  7. CT of abdominal tumor

    International Nuclear Information System (INIS)

    Endo, Satoshi; Yamada, Kenji; Ito, Masatoshi; Ito, Hisao; Yamaura, Harutsugu

    1981-01-01

    CT findings in 33 patients who had an abdominal tumor were evaluated. CT revealed a tumor in 31 cases. The organ from which the tumor originated was correctly diagnosed in 18 patients. Whether the tumor was solid or cystic was correctly predicted in 28 patients. The diagnosis malignant or benign nature of tumor was correct, incorrect and impossible, in 23, 3, and five patiens, respectively. (Kondo, M.)

  8. Emergency CT in blunt abdominal trauma of multiple injury patients

    International Nuclear Information System (INIS)

    Kinnunen, J.; Kivioja, A.; Poussa, K.; Laasonen, E.M.

    1994-01-01

    Multiple injury patients with blunt abdominal trauma (n = 110) were examined by abdominal CT. An i.v., but not peroral, contrast medium was used, thereby eliminating the delay caused by administering peroral contrast medium and any subsequent delay in making the diagnoses and beginning operative treatment. Eighteen patients underwent emergency laparotomy after the initial CT examination. The preoperative CT findings were compared to the laparotomy findings. CT revealed all but one of the severe parenchymal organ lesions requiring surgery. The one liver laceration that went undetected had caused hemoperitoneum, which was diagnosed by CT. The bowel and mesenteric lesions presented as intra-abdominal blood, and the hemoperitoneum was discovered in every patient with these lesions. Fourteen patients also initially had positive abdominal CT findings; 10 of them underwent an additional abdominal CT within 3 days, but the repeat studies did not reveal any lesions in need of surgery. Omission of the oral contrast medium did not jeopardize making the essential diagnoses, but it did save time. (orig.)

  9. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... of CT Scanning of the Abdomen and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed ... soft tissues and blood vessels. top of page What are some common uses of the procedure? This ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  12. Abdominal spiral CT in children: which radiation exposure is required?

    Energy Technology Data Exchange (ETDEWEB)

    Wormanns, D.; Diederich, S.; Lenzen, H.; Ludwig, K.; Papke, Karsten; Hagedorn, Claudia; Heindel, Walter [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Lange, P.; Link, T.M. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Dept. of Radiology, Technical Univ. Muenchen (Germany)

    2001-11-01

    We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: group A with reduced radiation exposure (tube current 50 mA, CT dose index CTDI{sub FDA} {<=}0.83 mGy) and group B with standard radiation exposure (tube current {>=}100 mA, CTDI{sub FDA} {>=}1.66 mGy). Image quality was assessed using a four-part scale ('excellent', 'good', 'sufficient', 'poor') on visual image impression and visibility of 32 anatomical details. Five experienced radiologists read the CT scans independently who were blinded to the examination parameters. Differences in ranked data were evaluated with Wilcoxon's rank sum test. No difference between groups A and B was observed in visual image impression. Detail visibility was significantly lower in group A, but the differences were limited to right upper quadrant structures (portal vein, common bile duct, pancreatic head, adrenals) and to arterial branches. Significant differences in visibility rated as 'poor' were only found for the hepatic, splenic and renal arteries; all other structures showed no difference between groups A and B. A protocol with reduced radiation exposure (50 mA, CTDI{sub FDA} {<=}0.83 mGy) allowed the demonstration of most anatomic structures in abdominal spiral CT in young children. For the precise demonstration of small details (e.g. structures of the right upper quadrant), a protocol with standard radiation exposure ({>=}100 mAs) was superior. (orig.)

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist can ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  14. Cone beam CT for organs motion evaluation in pediatric abdominal neuroblastoma

    International Nuclear Information System (INIS)

    Nazmy, Mohamed Soliman; Khafaga, Yasser; Mousa, Amr; Khalil, Ehab

    2012-01-01

    Background and purpose: To quantify the organ motion relative to bone in different breathing states in pediatric neuroblastoma using cone beam CT (CBCT) for better definition of the planning margins during abdominal IMRT. Methods and materials: Forty-two datasets of kV CBCT for 9 pediatric patients with abdominal neuroblastoma treated with IMRT were evaluated. Organs positions on planning CT scan were considered the reference position against which organs and target motions were evaluated. The position of the kidneys and the liver was assessed in all scans. The target movement was evaluated in four patients who were treated for gross residual disease. Results: The mean age of the patients was 4.1 ± 1.6 years. The range of target movement in the craniocaudal direction (CC) was 5 mm. In the CC direction, the range of movement was 10 mm for the right kidney, and 8 mm for the left kidney. Similarly, the liver upper edge range of motion was 11 mm while the lower edge range of motion was 13 mm. Conclusions: With the use of daily CBCT we may be able to reduce the PTV margin. If CBCT is not used daily, a wider margin is needed.

  15. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  16. Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry

    Energy Technology Data Exchange (ETDEWEB)

    Manios, G.E.; Mazonakis, M.; Damilakis, J. [University of Crete, Department of Medical Physics, Faculty of Medicine, Heraklion, Crete (Greece); Voulgaris, C.; Karantanas, A. [University of Crete, Department of Radiology, Faculty of Medicine, Heraklion, Crete (Greece)

    2016-03-15

    To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95 % limits of agreement were also acceptable (VAF: -16.5 %, 16.1 %; SAF: -10.8 %, 10.7 %) and the repeatability of stereology was good (VAF: CV = 4.5 %, SAF: CV = 3.2 %). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. (orig.)

  17. Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

    International Nuclear Information System (INIS)

    Khawaja, Ranish Deedar Ali; Singh, Sarabjeet; Otrakji, Alexi; Padole, Atul; Lim, Ruth; Nimkin, Katherine; Westra, Sjirk; Kalra, Mannudeep K.; Gee, Michael S.

    2015-01-01

    Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT. (orig.)

  18. Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, Ranish Deedar Ali; Singh, Sarabjeet; Otrakji, Alexi; Padole, Atul; Lim, Ruth; Nimkin, Katherine; Westra, Sjirk; Kalra, Mannudeep K.; Gee, Michael S. [MGH Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2015-07-15

    Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT. (orig.)

  19. Colon distension and scan protocol for CT-colonography: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Thierry N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Haan, Margriet C. de, E-mail: m.c.dehaan@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Venema, Henk W., E-mail: h.w.venema@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Stoker, Jaap, E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands)

    2013-08-15

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension, automatic carbon dioxide insufflation should be performed, preferably via a thin, flexible catheter. Hyoscine butylbromide is – when available – the preferred spasmolytic agent because of the positive effect on insufflation and pain/burden and its low costs. Scans in two positions are required for adequate distension and high polyp sensitivity and decubitus position may be used as an alternative for patients unable to lie in prone position. The great intrinsic contrast between air or tagging and polyps allows the use of low radiation dose. Low-dose protocol without intravenous contrast should be used when extracolonic findings are deemed unimportant. In patients suspected for colorectal cancer, normal abdominal CT scan protocols and intravenous contrast should be used in supine position for the evaluation of extracolonic findings. Dose reduction can be obtained by lowering the tube current and/or voltage. Tube current modulation reduces the radiation dose (except in obese patients), and should be used when available. Iterative reconstructions is a promising dose reducing tool and dual-energy CT is currently evaluated for its applications in CT-colonography. This review also provides our institution's insufflation procedure and scan parameters.

  20. CT findings in abdominal actinomycosis

    International Nuclear Information System (INIS)

    Lee, In Jae; Ha, Hyun Kwon; Lee, Moon Gyu; Kim, Pyo Nyun; Auh, Yong Ho

    1999-01-01

    Abdominal actinomycosis is a chronic, progressive, suppurative disease with a favorable response to intravenous treatment with penicillin. In many instances, however, its clinical and radiological findings may overlap with those of other inflammatory and neoplastic conditions, and the familiarity with the various radiological features can thus avoid diagnostic delays. The purpose of this paper is to describe and discuss the CT findings of abdominal actinomycosis

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  2. The CT frequencies of various non-traumatic acute abdominal emergencies in hemodialysis, peritoneal dialysis patients and the general population

    International Nuclear Information System (INIS)

    Ergün, Tarkan; Lakadamyal, Hatice

    2012-01-01

    Purpose: To investigate the frequency of non-traumatic acute abdominal emergencies in end-stage renal disease (ESRD) (peritoneal dialysis (PD) and haemodialysis (HD)) patients and in the general population as diagnosed by computed tomography (CT) imaging. Methods: The abdominal CT findings of ESRD patients with non-traumatic acute abdominal pain during the years 2001–2010 have been retrospectively evaluated. Thirty-three HD (14 females, 19 males, mean age: 62 ± 10.5) and 22 PD patients (12 females, 10 males, mean age: 59 ± 9.4) with acute abdominal pathology based on their CT scans have been included into the study. In addition, 127 individuals (68 females, 59 males, mean age: 40.7 ± 12.8) with normal renal functions who presented with non-traumatic acute abdominal pain diagnosed with an acute abdominal pathology based on their CT scans have been prospectively evaluated during the years 2009–2010. Results: While the most frequent etiology in PD patients was peritonitis (45.4%), acute pancreatitis (13.6%) and perforation (18.1), and in HD patients it was nonocclusive mesenteric ischemia (18.1%) and spontaneous intraabdominal bleeding (21.2%). The basic causes of acute abdomen in the general population were ureteral stone (34.6%) and appendicitis (18.1%). Conclusions: The causes of acute abdominal pain in ESRD patients is significantly different when compared to the general population. And within this special patient population the etiology of acute abdomen differs depending on the renal replacement therapy modality they are receiving. Thus, the causes of acute abdomen in PD patients are mostly peritonitis, acute pancreatitis, and perforation, while being mostly nonocclusive mesenteric ischemia and spontaneous intraabdominal bleeding in patients receiving HD therapy.

  3. 4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yong, E-mail: hu.yong@zs-hospital.sh.cn; Zhou, Yong-Kang, E-mail: zhouyk2009@163.com; Chen, Yi-Xing, E-mail: chen.yixing@zs-hospital.sh.cn; Shi, Shi-Ming, E-mail: shiming32@126.com; Zeng, Zhao-Chong, E-mail: zeng.zhaochong@zs-hospital.sh.cn [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, 180 Feng Lin Road, Shanghai 200032 (China)

    2016-07-15

    Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z

  4. Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image quality

    International Nuclear Information System (INIS)

    Amacker, Nadja A.; Mader, Caecilia; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2012-01-01

    Objective: To investigate the radiation dose and image quality of the high-pitch dual source computer tomography (DSCT) for routine chest and abdominal scans. Methods: 130 consecutive patients (62 female, 68 male, median age 55 years) were included. All patients underwent 128-slice high-pitch DSCT (chest n = 99; abdomen n = 84) at a pitch of 3.2. Two observers independently rated image quality using a 4-point score (1: excellent to 4: non-diagnostic). Image noise was measured and operational radiation dose quantities were recorded. An additional group of 132 patients (chest, n = 80; abdomen n = 52) scanned with standard-pitch CT matched for age, gender, and body mass index (BMI) served as control group. Results: Interobserver agreement for image quality rating was good (k = 0.74). Subjective image quality of high-pitch CT was diagnostic in all patients (median score chest; 2, median score abdomen: 2). Image noise of high-pitch CT was comparable to standard-pitch for the chest (p = 0.32) but increased in the abdomen (p < 0.0001). For high-pitch CT radiation dose was 4.4 ± 0.9 mSv (chest) and 6.5 ± 1.2 mSv (abdomen). These values were significantly lower compared to standard-pitch CT (chest: 5.5 ± 1.2 mSv; abdomen: 11.3 ± 3.8 mSv). Conclusion: Based on the technical background high-pitch dual source CT may serve as an alternative scan mode for low radiation dose routine chest and abdominal CT.

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  6. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  7. Value of a probabilistic atlas in medical image segmentation regarding non-rigid registration of abdominal CT scans

    Science.gov (United States)

    Park, Hyunjin; Meyer, Charles R.

    2012-10-01

    A probabilistic atlas provides important information to help segmentation and registration applications in medical image analysis. We construct a probabilistic atlas by picking a target geometry and mapping other training scans onto that target and then summing the results into one probabilistic atlas. By choosing an atlas space close to the desired target, we construct an atlas that represents the population well. Image registration used to map one image geometry onto another is a primary task in atlas building. One of the main parameters of registration is the choice of degrees of freedom (DOFs) of the geometric transform. Herein, we measure the effect of the registration's DOFs on the segmentation performance of the resulting probabilistic atlas. Twenty-three normal abdominal CT scans were used, and four organs (liver, spinal cord, left and right kidneys) were segmented for each scan. A well-known manifold learning method, ISOMAP, was used to find the best target space to build an atlas. In summary, segmentation performance was high for high DOF registrations regardless of the chosen target space, while segmentation performance was lowered for low DOF registrations if a target space was far from the best target space. At the 0.05 level of statistical significance, there were no significant differences at high DOF registrations while there were significant differences at low DOF registrations when choosing different targets.

  8. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors.

    Science.gov (United States)

    Yu, Tong; Gao, Jun; Liu, Zhi-Min; Zhang, Qi-Feng; Liu, Yong; Jiang, Ling; Peng, Yun

    2017-04-05

    Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors. Forty-five patients with solid tumors who had initial CT (Group B) and follow-up CT (Group A) after chemotherapy were enrolled. The initial diagnostic CT scan (Group B) was performed using the standard two-phase enhanced CT with 320 mgI/ml concentration contrast, and the follow-up scan (Group A) was performed using a single-phase enhanced CT at 45 s after the beginning of the 270 mgI/ml contrast injection using spectral mode. Forty percent ASiR was used for the images in Group B and monochromatic images with energy levels ≥60 keV in Group A. In addition, filtered back-projection (FBP) reconstruction was used for monochromatic images hounsfield unit (HU). The abdominal organs of Groups A and B had similar degrees of absolute and relative enhancement (t = 0.36 and -1.716 for liver, -0.153 and -1.546 for pancreas, and 2.427 and 0.866 for renal cortex, all P> 0.05). Signal-to-noise ratio of the abdominal organs was significantly lower in Group A than in Group B (t = -8.11 for liver, -7.83 for pancreas, and -5.38 for renal cortex, all P 3, indicating clinically acceptable image quality. Single-phase, dual-energy spectral CT used for children with solid abdominal tumors can reduce contrast dose and radiation dose and can also maintain clinically acceptable image quality.

  9. CT features of abdominal plasma cell neoplasms

    International Nuclear Information System (INIS)

    Monill, J.; Pernas, J.; Montserrat, E.; Perez, C.; Clavero, J.; Martinez-Noguera, A.; Guerrero, R.; Torrubia, S.

    2005-01-01

    The aim of this study was to describe the CT features of abdominal plasma cell neoplasms. We reviewed CT imaging findings in 11 patients (seven men, four women; mean age 62 years) with plasma cell neoplasms and abdominal involvement. Helical CT of the entire abdomen and pelvis was performed following intravenous administration of contrast material. Images were analyzed in consensus by two radiologists. Diagnoses were made from biopsy, surgery and/or clinical follow-up findings. Multiple myeloma was found in seven patients and extramedullary plasmacytoma in four patients. All patients with multiple myeloma had multifocal disease with involvement of perirenal space (4/7), retroperitoneal and pelvic lymph nodes (3/7), peritoneum (3/7), liver (2/7), subcutaneous tissues (2/7) and kidney (1/7). In three of the four patients with extramedullary plasmacytoma, a single site was involved, namely stomach, vagina and retroperitoneum. In the fourth patient, a double site of abdominal involvement was observed with rectal and jejunal masses. Plasma cell neoplasm should be considered in the differential diagnosis of single or multiple enhancing masses in the abdomen or pelvis. Abdominal plasma cell neoplasms were most frequently seen as well-defined enhancing masses (10/11). (orig.)

  10. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    Science.gov (United States)

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  11. Fat necrosis after abdominal surgery: A pitfall in interpretation of FDG-PET/CT.

    Science.gov (United States)

    Davidson, Tima; Lotan, Eyal; Klang, Eyal; Nissan, Johnatan; Goldstein, Jeffrey; Goshen, Elinor; Ben-Haim, Simona; Apter, Sara; Chikman, Bar

    2018-06-01

    We describe FDG-PET/CT findings of postoperative fat necrosis in patients following abdominal surgery, and evaluate their changes in size and FDG uptake over time. FDG-PET/CT scans from January 2007-January 2016 containing the term 'fat necrosis' were reviewed. Lesions meeting radiological criteria of fat necrosis in patients with prior abdominal surgery were included. Forty-four patients, 30 males, mean age 68.4 ± 11.0 years. Surgeries: laparotomy (n=37; 84.1 %), laparoscopy (n=3; 6.8 %), unknown (n=4; 9.1 %). CTs of all lesions included hyperdense well-defined rims surrounding a heterogeneous fatty core. Sites: peritoneum (n=34; 77 %), omental fat (n=19; 43 %), subcutaneous fat (n=8; 18 %), retroperitoneum (n=2; 5 %). Mean lesion long axis: 33.6±24.9 mm (range: 13.0-140.0). Mean SUVmax: 2.6±1.1 (range: 0.6-5.1). On serial CTs (n=34), lesions decreased in size (p=0.022). Serial FDG-PET/CT (n=24) showed no significant change in FDG-avidity (p=0.110). Mean SUVmax did not correlate with time from surgery (p=0.558) or lesion size (p=0.259). Postsurgical fat necrosis demonstrated characteristic CT features and may demonstrate increased FDG uptake. However, follow-up of subsequent imaging scans showed no increases in size or FDG-avidity. Awareness of this entity is important to avoid misinterpretation of findings as recurrent cancer. • Postsurgical fat necrosis may mimic cancer in FDG-PET/CT. • Follow-up of fat necrosis showed no increase in FDG intensity. • CT follow-up showed a decrease in lesion size. • FDG uptake did not correlate with time lapsed from surgery.

  12. A Method for the Automatic Exposure Control in Pediatric Abdominal CT: Application to the Standard Deviation Value and Tube Current Methods by Using Patient's Age and Body Size.

    Science.gov (United States)

    Furuya, Ken; Akiyama, Shinji; Nambu, Atushi; Suzuki, Yutaka; Hasebe, Yuusuke

    2017-01-01

    We aimed to apply the pediatric abdominal CT protocol of Donnelly et al. in the United States to the pediatric abdominal CT-AEC. Examining CT images of 100 children, we found that the sectional area of the hepatic portal region (y) was strongly correlated with the body weight (x) as follows: y=7.14x + 84.39 (correlation coefficient=0.9574). We scanned an elliptical cone phantom that simulates the human body using a pediatric abdominal CT scanning method of Donnelly et al. in, and measured SD values. We further scanned the same phantom under the settings for adult CT-AEC scan and obtained the relationship between the sectional areas (y) and the SD values. Using these results, we obtained the following preset noise factors for CT-AEC at each body weight range: 6.90 at 4.5-8.9 kg, 8.40 at 9.0-17.9 kg, 8.68 at 18.0-26.9 kg, 9.89 at 27.0-35.9 kg, 12.22 at 36.0-45.0 kg, 13.52 at 45.1-70.0 kg, 15.29 at more than 70 kg. From the relation between age, weight and the distance of liver and tuber ischiadicum of 500 children, we obtained the CTDI vol values and DLP values under the scanning protocol of Donnelly et al. Almost all of DRL from these values turned out to be smaller than the DRL data of IAEA and various countries. Thus, by setting the maximum current values of CT-AEC to be the Donnelly et al.'s age-wise current values, and using our weight-wise noise factors, we think we can perform pediatric abdominal CT-AEC scans that are consistent with the same radiation safety and the image quality as those proposed by Donnelly et al.

  13. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    International Nuclear Information System (INIS)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge

    2014-01-01

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  14. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge [Dept. of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou (China)

    2014-08-15

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  15. Multidetector CT findings of bowel Transection in blunt abdominal trauma

    International Nuclear Information System (INIS)

    Cho, Hyun Suk; Woo, Ji Young; Hong, Hye Suk; Park, Mee Hyun; Yang, Ik; Lee, Yul; Jung, Ah Young; Hwang, Ji Young; Ha, Hong Il

    2013-01-01

    Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity.

  16. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  17. Combined endeavor of Neutrosophic Set and Chan-Vese model to extract accurate liver image from CT scan.

    Science.gov (United States)

    Siri, Sangeeta K; Latte, Mrityunjaya V

    2017-11-01

    Many different diseases can occur in the liver, including infections such as hepatitis, cirrhosis, cancer and over effect of medication or toxins. The foremost stage for computer-aided diagnosis of liver is the identification of liver region. Liver segmentation algorithms extract liver image from scan images which helps in virtual surgery simulation, speedup the diagnosis, accurate investigation and surgery planning. The existing liver segmentation algorithms try to extort exact liver image from abdominal Computed Tomography (CT) scan images. It is an open problem because of ambiguous boundaries, large variation in intensity distribution, variability of liver geometry from patient to patient and presence of noise. A novel approach is proposed to meet challenges in extracting the exact liver image from abdominal CT scan images. The proposed approach consists of three phases: (1) Pre-processing (2) CT scan image transformation to Neutrosophic Set (NS) and (3) Post-processing. In pre-processing, the noise is removed by median filter. The "new structure" is designed to transform a CT scan image into neutrosophic domain which is expressed using three membership subset: True subset (T), False subset (F) and Indeterminacy subset (I). This transform approximately extracts the liver image structure. In post processing phase, morphological operation is performed on indeterminacy subset (I) and apply Chan-Vese (C-V) model with detection of initial contour within liver without user intervention. This resulted in liver boundary identification with high accuracy. Experiments show that, the proposed method is effective, robust and comparable with existing algorithm for liver segmentation of CT scan images. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Quantifying the usefulness of CT in evaluating seniors with abdominal pain

    International Nuclear Information System (INIS)

    Lewis, Lawrence M.; Klippel, Allen P.; Bavolek, Rebecca A.; Ross, Laura M.; Scherer, Tara M.; Banet, Gerald A.

    2007-01-01

    Objectives: (1) Determine if older patients with abdominal pain who receive emergency department (ED) abdominal CT have changes in diagnosis and/or disposition more often than similar patients without CT; (2) compare physician confidence in diagnosis and disposition for patients with versus without CT; (3) document factors that most influence physician's decision to order abdominal CT in this population. Methods: ED patients 60 years of age or older, with acute non-traumatic abdominal pain were enrolled over a 6-week period. Physicians documented a preliminary and final ED diagnosis and disposition, along with pre- and post-evaluation confidence levels. Decision to order CT, along with clinical information most influencing that decision, was noted. Physician confidence levels and percent change in diagnosis and disposition were compared for patients with versus without CT. Results: One hundred and twenty-six patients comprised study sample. Abdominal CT rate was 59% (95%CI, 50-67%). CT was associated with an increased change in diagnosis (46%; 95%CI, 4-58% versus 29%; 95%CI, 16-42%), but no change in disposition between patients with versus without CT. Preliminary diagnostic confidence was lower for EPs who ordered a CT than for those who did not (p < 0.001). Patient history most influenced ordering CT, whereas prior lab/imaging results most influenced not ordering CT. Conclusion: Patients with CT had a change in diagnosis more often than those without. Preliminary diagnostic confidence was lower in CT group. Percent change in disposition did not differ between groups. Physicians most often ordered CT based on history and did not order CT when other diagnostic evaluation supported a specific diagnosis

  19. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  20. Computed tomography and nonoperative treatment for blunt abdominal trauma

    International Nuclear Information System (INIS)

    Watanabe, Shinsuke; Ishi, Takashi; Kamachi, Masahiro; Takahashi, Toshio.

    1990-01-01

    Studies were undertaken to determine if computed tomography (CT) could reliably assist physical examination in the initial assessment of blunt abdominal trauma, and also to examine how various abdominal injuries were managed with the guidance of CT. A total of 255 patients underwent emergency abdominal CT following blunt abdominal trauma over a period of seven years. One hundred and fifty two patients had abnormal CT scans, including 58 hepatic, 36 renal, 25 splenic and 9 pancreatic injuries as well as 67 patients with intra-abdominal hemorrhage and 21 patients with free abdominal air. A comparative study on the detection of pneumoperitoneum revealed CT to be far superior to plain radiography. One hundred and three patients had normal CT scans, all of whom were managed nonoperatively, except for three false-negative cases and two nontherapeutic cases. The patients with injury to the parenchymal organs were given nonoperative treatment if they had stable vital signs and no evidence of associated injuries demanding immediate surgery and the majority of these patients were managed well nonoperatively. CT was thus found to be a useful adjunct in the management of victims of blunt abdominal trauma, since in a rapid and noninvasive fashion, CT accurately defined the extent of parenchymal organ injury and also disclosed any other abdominal injuries. (author)

  1. Computed tomography and nonoperative treatment for blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Shinsuke; Ishi, Takashi; Kamachi, Masahiro [Saiseikai Shiga Hospital, Shiga (Japan); Takahashi, Toshio

    1990-01-01

    Studies were undertaken to determine if computed tomography (CT) could reliably assist physical examination in the initial assessment of blunt abdominal trauma, and also to examine how various abdominal injuries were managed with the guidance of CT. A total of 255 patients underwent emergency abdominal CT following blunt abdominal trauma over a period of seven years. One hundred and fifty two patients had abnormal CT scans, including 58 hepatic, 36 renal, 25 splenic and 9 pancreatic injuries as well as 67 patients with intra-abdominal hemorrhage and 21 patients with free abdominal air. A comparative study on the detection of pneumoperitoneum revealed CT to be far superior to plain radiography. One hundred and three patients had normal CT scans, all of whom were managed nonoperatively, except for three false-negative cases and two nontherapeutic cases. The patients with injury to the parenchymal organs were given nonoperative treatment if they had stable vital signs and no evidence of associated injuries demanding immediate surgery and the majority of these patients were managed well nonoperatively. CT was thus found to be a useful adjunct in the management of victims of blunt abdominal trauma, since in a rapid and noninvasive fashion, CT accurately defined the extent of parenchymal organ injury and also disclosed any other abdominal injuries. (author).

  2. Automated segmentation and recognition of abdominal wall muscles in X-ray torso CT images and its application in abdominal CAD

    International Nuclear Information System (INIS)

    Zhou, X.; Kamiya, N.; Hara, T.; Fujita, H.; Chen, H.; Yokoyama, R.; Hoshi, H.

    2007-01-01

    The information of abdominal wall is very important for the planning of surgical operation and abdominal organ recognition. In research fields of computer assisted radiology and surgery and computer-aided diagnosis, the segmentation and recognition of the abdominal wall muscles in CT images is a necessary pre-processing step. Due to the complexity of the abdominal wall structure and indistinctive in CT images, the automated segmentation of abdominal wall muscles is a difficult issue and has not been solved completely. We propose an approach to segment the abdominal wall muscles and divide it into three categories (front abdominal muscles including rectus abdominis; left and right side abdominal muscles including external oblique, internal oblique and transversus abdominis muscles) automatically. The approach, first, makes an initial classification of bone, fat, and muscles and organs based on the CT number. Then a layer structure is generated to describe the 3-D anatomical structures of human torso by stretching the torso region onto a thin-plate for easy recognition. The abdominal wall muscles are recognized on the layer structures using the spatial relations to the skeletal structure and CT numbers. Finally, the recognized regions are mapped back to the 3-D CT images using an inverse transformation of the stretching process. This method is applied to 20 cases of torso CT images and evaluations are based on visual comparison of the recognition results and the original CT images by an expert in anatomy. The results show that our approach can segment and recognize abdominal wall muscle regions effectively. (orig.)

  3. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    Science.gov (United States)

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p 92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Assessment of the accuracy of AortaScan for detection of abdominal aortic aneurysm (AAA).

    Science.gov (United States)

    Abbas, A; Smith, A; Cecelja, M; Waltham, M

    2012-02-01

    AortaScan AMI 9700 is a portable 3D ultrasound device that automatically measures the maximum diameter of the abdominal aorta without the need for a trained sonographer. It is designed to rapidly diagnose or exclude an AAA and may have particular use in screening programs. Our objective was to determine its accuracy to detect AAA. Subjects from our AAA screening and surveillance programs were examined. The aorta was scanned using the AortaScan and computed tomography (CT). Ninety-one subjects underwent imaging (44 AAA on conventional ultrasound surveillance and 47 controls). The largest measurement obtained by AortaScan was compared against the CT-aortic measurement. The mean aortic diameter was 2.8 cm. The CT scan confirmed the diagnosis of AAA in 43 subjects. There was one false positive measurement on conventional ultrasound. AortaScan missed the diagnosis of AAA in eight subjects. There were thirteen false positive measurements. The sensitivity, specificity, positive and negative predictive values were 81%, 72%, 72% and 81% respectively. A device to detect AAA without the need for a trained operator would have potential in a community-based screening programme. The AortaScan, however, lacks adequate sensitivity and significant technical improvement is necessary before it could be considered a replacement for trained screening personnel. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  5. CT diagnosis of concealed rupture of intestine following abdominal trauma

    International Nuclear Information System (INIS)

    Ji Jiansong; Wei Tiemin; Wang Zufei; Zhao Zhongwei; Tu Jianfei; Fan Xiaoxi; Xu Min

    2009-01-01

    Objective: To investigate CT findings of concealed rupture of intestine following abdominal trauma. Methods: CT findings of 11 cases with concealed rupture of intestine following abdominal trauma proved by surgery were identified retrospectively. Results: The main special signs included: (1) Free air in 4 cases, mainly around injured small bowel or under the diaphragm, or in the retroperitoneal space or and in the lump. (2) High density hematoma between the intestines or in the bowel wall (4 cases). (3) Bowel wall injury sign, demonstrated as low density of the injured intestinal wall, attenuated locally but relatively enhanced in neighbor wall on enhanced CT. (4) Lump around the injured bowel wall with obvious ring-shaped enhancement (4 cases). Other signs included: (1) Free fluid in the abdominal cavity or between the intestines with blurred borders. (2) Bowel obstruction. Conclusion: CT is valuable in diagnosing concealed rupture of intestine following abdominal trauma. (authors)

  6. Contrast Dose and Radiation Dose Reduction in Abdominal Enhanced Computerized Tomography Scans with Single-phase Dual-energy Spectral Computerized Tomography Mode for Children with Solid Tumors

    OpenAIRE

    Tong Yu; Jun Gao; Zhi-Min Liu; Qi-Feng Zhang; Yong Liu; Ling Jiang; Yun Peng

    2017-01-01

    Background: Contrast dose and radiation dose reduction in computerized tomography (CT) scan for adult has been explored successfully, but there have been few studies on the application of low-concentration contrast in pediatric abdominal CT examinations. This was a feasibility study on the use of dual-energy spectral imaging and adaptive statistical iterative reconstruction (ASiR) for the reduction of radiation dose and iodine contrast dose in pediatric abdominal CT patients with solid tumors...

  7. Abdominal wall hernias: computed tomography findings; Hernias da parede abdomino-pelvica: aspectos tomograficos

    Energy Technology Data Exchange (ETDEWEB)

    D' Ippolito, Giuseppe; Rosas, George de Queiroz; Mota, Marcos Alexandre; Akisue, Sandra R. Tsukada; Galvao Filho, Mario de Melo[Hospital e Maternidade Sao Luiz, Sao Paulo, SP (Brazil). Setor de US/TC/RMN]. E-mail: giuseppe_dr@uol.com.br

    2005-07-15

    Abdominal hernias are a common clinical problem Clinical diagnosis of abdominal hernias can sometimes be challenging, particularly in obese patients or patients with previous abdominal surgery. CT scan of the abdomen allows visualization of hernias and their contents and the differentiation from other masses of the abdominal wall such as tumors, hematomas and abscesses. Moreover, CT may identify complications such as incarceration, bowel obstruction, volvulus and strangulation. This study illustrates the CT scan findings observed in different types of abdominal wall hernias. (author)

  8. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  9. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT) of the abdomen and pelvis is a diagnostic imaging test used to help detect diseases of ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  14. Asymptomatic renal cell carcinoma incidentally detected by abdominal CT

    International Nuclear Information System (INIS)

    Yoneda, Fumio; Miyake, Noriaki; Tsujimura, Haruhiro; Nakajima, Mikio; Akiyama, Hajime

    1987-01-01

    Four cases of renal cell carcinoma that were incidentally detected by abdominal CT are reported. Abdominal CT was performed during gastro-intestinal examination in two patients and for suspected liver disease in the other two. No patient had symptoms of renal cell carcinoma, or hematuria. In all cases, the histopathological diagnosis was renal cell carcinoma of a low stage. (author)

  15. CT diagnosis of abdominal abscess in children

    International Nuclear Information System (INIS)

    Li Xin; Yang Zhiyong

    1998-01-01

    Purpose: To evaluate CT in the diagnosis of abdominal abscess in children. Methods: Analysis of CT manifestations in 23 cases proved by operation and needle aspiration. Causes: acute appendicitis 13 cases, ascending colon perforation 1 case, Meckel diverticulitis 2 cases, cause obscured 7 cases. Bolus injection of contrast medium was given in 19 cases. Results: The CT value had no relationship to the course of disease and type of bacteria, amount of abscess had positive relevance relative with course of illness. Air-fluid level or scattered gas bubbles was seen in abscesses in 52%; little calcified plague was present in 22%. All cases presented nonhomogeneous thick wall enhancement after one week of illness. Conclusion: The characteristic CT features of intra-abdominal abscess were the presence of air and little calcified plague shadow; a large air-fluid level was indicative of fistula, while the absence of air in the abscess can not exclude fistula

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  17. Evaluation of abdominal trauma by computed tomography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  18. Evaluation of abdominal trauma by computed tomography and ultrasonography

    International Nuclear Information System (INIS)

    Lee, Do Yun; Kim, Sang Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1986-01-01

    Out of 75 patients who were admitted to our hospital because of abdominal trauma and were undergone the procedures such as ultrasonography and/or CT scan within 24 hours of abdominal trauma due to suspected abdominal organ injury. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. We analyzed the results of 38 patients who were confirmed of diagnosis by operation, follow-up CT scan or ultrasonography. 1. In the abdominal organ injury, solid organ injury consists of 8 cases of spleen laceration, 1 of splenic subcapsular hematoma, 7 of hepatic laceration, 7 of pancreas laceration, 3 of renal laceration, and 3 of subcapsular hematoma of kidney. 2. In addition, there were 7 bowel and/or mesenteric laceration, 2 diaphragmatic hernia, and 1 urethral rupture. 3. 2 cases of retroperitoneal hematoma and 1 case in which hemo peritoneum occurred without abdominal organ injury were confirmed by follow-up CT or ultrasonography. 4. In all of the 4 patients with multiple organ injury, pancreatic laceration was associated. 5. In abdominal trauma patients, ultrasonography or CT can be used to survey rapidly the entire abdomen for possible associated injury, and be of great help to clinicians in identifying the patients who need immediate surgery or in minimizing the incidence of unnecessary emergency abdominal exploration.

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  20. animal trial on imaging appearances of abdominally retained gauze

    International Nuclear Information System (INIS)

    Wang Longxia; An Ningyu; Yin Hui; Wang Xiangdong; Li Jia; Bai Ying

    2000-01-01

    Objective: To evaluate the imaging appearances of abdominally retained crumpled gauze with US, CT and MRI and the changes with time. Methods: Eight rabbits were operated and crumpled gauze was put into in their abdominal cavity. US , plain and enhanced CT and MRI scan were performed on the day of operation, and 1 to 7 weeks after operation. The imaging appearances were compared with operation findings. Pathologic examination was done simultaneously. Results: Abdominally retained crumpled gauze was instantly adhesive with omentum and neighboring intestines tightly. Fibro-connective tissue membrane was produced at the adhesion site gradually, spreading out to enclose the crumpled gauze. The enclosure was finished completely in 3 to 4 weeks. Thickened membrane also invaded into the spaces within the gauze. The crumpled gauze was eventually infected. These changes could be revealed on US, CT or MRI scans. The US appearance exhibited a hyper echoic arc zone with broad clean acoustic shadow behind. It appeared as a soft tissue mass to CT and MRI scans. In early stage CT scan could easily show the gas within the crumpled gauze. CT and MRI enhanced scans showed only the enhanced membrane and no enhancement of the crumpled gauze. Conclusion: US, CT and MRI have quite characteristic appearances of the abdominally retained crumpled gauze, especially when combined imaging techniques were employed, which can lead to a correct diagnosis together with a history of operation

  1. Pitfalls in diagnosing colon cancer on abdominal CT.

    Science.gov (United States)

    Klang, E; Eifer, M; Kopylov, U; Belsky, V; Raskin, S; Konen, E; Amitai, M M

    2017-10-01

    To assess the frequency of undetected colon cancer on conventional abdominal CT and to evaluate the imaging features that are characteristic of those cancers. The present study included consecutive patients diagnosed with colorectal cancer at colonoscopy (2006-2015) who also underwent abdominal computed tomography (CT) performed for various reasons within a year prior to the colonoscopy. The frequency of undetected lesions was evaluated for the original CT interpretations ("original readers"). Two radiologists ("study readers"), blinded to the tumour location, independently performed interpretations oriented for colon cancer detection. The study readers analysed the imaging features of detected tumours (tumour shape, length, maximal wall thickness, free fluid, fat stranding, vascular engorgement, stenosis, and lymphadenopathy). Imaging features of the cancers undetected by the original readers were evaluated. The study included 127 patients. The original readers' frequency of undetected cancer was 25/127 (19.7%). Each study reader could not identify the cancer in 8/127 (6.3%) patients. Imaging features associated with undetected cancers by the original readers included the absence of fat stranding (p=0.007, p=0.003), absence of vascular engorgement (pColon cancer is undetected in 20% of abdominal CT examinations in patients subsequently proven to have colon cancer at colonoscopy. The absence of fat stranding, vascular engorgement, or lymphadenopathy, and an average tumour length of 3.3 cm are contributing factors for failure of detection. Radiologists' training should emphasis these findings as it may improve cancer detection, and clinicians should be aware of the limitations of abdominal CT. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Improvement of CT-based treatment planning models of abdominal targets using static exhale imaging

    International Nuclear Information System (INIS)

    Ten Haken, R.K.; Balter, J.M.; Lam, K.L.; McGinn, C.J.; Lawrence, T.S.

    1996-01-01

    PURPOSE: CT based models of the patient that do not account for the motion of ventilation may not accurately predict the shape and position of critical abdominal structures. Without knowledge of the patient's ventilatory status during the CT scan, a planning target volume margin for the entire range of ventilation is required both inferior and superior to abdominal target volumes to ensure coverage. Also, dose-volume histograms and normal tissue complication probability (NTCP) estimates may be uncertain. Respiratory gating technology for imaging and treatment is not yet widely available. The purpose of the current study is to explore an intermediate step to improve the veracity of the patient model and reduce the treated volume by acquiring the CT data with the patients holding their breath at normal exhale. MATERIALS AND METHODS: The ventilatory time courses of diaphragm movement for 15 patients (with no special breathing instructions) were measured using digitized movies from the fluoroscope during simulation. On repeat simulations, the reproducibility of the diaphragm position at exhale was determined. A clinical protocol was developed for treatment based on exhale CT models. CT scans were acquired at normal exhale using a spiral scanner. Typical volumes were acquired using 5 mm slice thickness and a 1:1 pitch. The scan volume was divided into 2-3 segments, to allow the patient to breathe in between. Margins were placed about intrahepatic target volumes based on the ventilatory excursion inferior to the target, and on only the reproducibility of exhale position superior to the target. RESULTS: The average patient's diaphragm was located within 2 mm of the average exhale position for 50% of the typical ventilatory cycle. For inhale, this value was reduced to 10%, and for mid ventilation, 15%. The reproducibility of exhale position over multiple breathing cycles was 2 mm (2σ), as opposed to 4 mm for inhale. Combining the variation of exhale position and the

  3. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  4. Extra-appendiceal findings in pediatric abdominal CT for suspected appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Halverson, Mark; Delgado, Jorge; Mahboubi, Soroosh [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2014-07-15

    Much has been written regarding the incidence, types, importance and management of abdominal CT incidental findings in adults, but there is a paucity of literature on incidental findings in children. We sought to determine the prevalence and characteristics of extra-appendiceal and incidental findings in pediatric abdominal CT performed for suspected appendicitis. A retrospective review was performed of abdominal CT for suspected appendicitis in a pediatric emergency department from July 2010 to June 2012. Extra-appendiceal findings were recorded. Any subsequent imaging was noted. Extra-appendiceal findings were divided into incidental findings of doubtful clinical significance, alternative diagnostic findings potentially providing a diagnosis other than appendicitis explaining the symptoms, and incidental findings that were abnormalities requiring clinical correlation and sometimes requiring further evaluation but not likely related to the patient symptoms. One hundred sixty-five children had abdominal CT for suspected appendicitis. Seventy-seven extra-appendiceal findings were found in 57 (34.5%) patients. Most findings (64 of 77) were discovered in children who did not have appendicitis. Forty-one of these findings (53%) could potentially help explain the patient's symptoms, while 30 of the findings (39%) were abnormalities that were unlikely to be related to the symptoms but required clinical correlation and sometimes further work-up. Six of the findings (8%) had doubtful or no clinical significance. Extra-appendiceal findings are common in children who undergo abdominal CT in the setting of suspected appendicitis. A significant percentage of these patients have findings that help explain their symptoms. Knowledge of the types and prevalence of these findings may help radiologists in the planning and interpretation of CT examinations in this patient population. (orig.)

  5. Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review.

    Science.gov (United States)

    Alshamari, Muhammed; Norrman, Eva; Geijer, Mats; Jansson, Kjell; Geijer, Håkan

    2016-06-01

    Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. Fifty-eight patients were imaged with both methods and were reviewed independently by three radiologists. The reference standard was obtained from the diagnosis in medical records. Sensitivity and specificity were calculated. A systematic review was performed after a literature search, finding a total of six relevant studies including the present. Overall sensitivity with 95 % CI for CT was 75 % (66-83 %) and 46 % (37-56 %) for radiography. Specificity was 87 % (77-94 %) for both methods. In the systematic review the overall sensitivity for CT varied between 75 and 96 % with specificity from 83 to 95 % while the overall sensitivity for abdominal radiography varied between 30 and 77 % with specificity 75 to 88 %. Based on the current study and available evidence, low-dose CT has higher diagnostic accuracy than abdominal radiography and it should, where logistically possible, replace abdominal radiography in the workup of adult patients with acute non-traumatic abdominal pain. • Low-dose CT has a higher diagnostic accuracy than radiography. • A systematic review shows that CT has better diagnostic accuracy than radiography. • Radiography has no place in the workup of acute non-traumatic abdominal pain.

  6. Computed Tomography (CT) Imaging of Injuries from Blunt Abdominal Trauma: A Pictorial Essay.

    Science.gov (United States)

    Hassan, Radhiana; Abd Aziz, Azian

    2010-04-01

    Blunt abdominal trauma can cause multiple internal injuries. However, these injuries are often difficult to accurately evaluate, particularly in the presence of more obvious external injuries. Computed tomography (CT) imaging is currently used to assess clinically stable patients with blunt abdominal trauma. CT can provide a rapid and accurate appraisal of the abdominal viscera, retroperitoneum and abdominal wall, as well as a limited assessment of the lower thoracic region and bony pelvis. This paper presents examples of various injuries in trauma patients depicted in abdominal CT images. We hope these images provide a resource for radiologists, surgeons and medical officers, as well as a learning tool for medical students.

  7. CT appearances of abdominal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.-K., E-mail: leewk33@hotmail.com [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Van Tonder, F.; Tartaglia, C.J.; Dagia, C. [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Cazzato, R.L. [Department of Radiology, Universita Campus Bio-Medico di Roma, Rome (Italy); Duddalwar, V.A. [Department of Radiology, Norris Comprehensive Cancer Center, University of Southern California, Los Angeles, California (United States); Chang, S.D. [Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, British Columbia (Canada)

    2012-06-15

    The purpose of this article is to review and illustrate the spectrum of computed tomography (CT) appearances of abdominal tuberculosis. Tuberculosis can affect any organ or tissue in the abdomen, and can be mistaken for other inflammatory or neoplastic conditions. The most common sites of tuberculosis in the abdomen include lymph nodes, genitourinary tract, peritoneal cavity and gastrointestinal tract. The liver, spleen, biliary tract, pancreas and adrenals are rarely affected, but are more likely in HIV-seropositive patients and in miliary tuberculosis. This article should alert the radiologist to consider abdominal tuberculosis in the correct clinical setting to ensure timely diagnosis and enable appropriate treatment.

  8. CT appearances of abdominal tuberculosis

    International Nuclear Information System (INIS)

    Lee, W.-K.; Van Tonder, F.; Tartaglia, C.J.; Dagia, C.; Cazzato, R.L.; Duddalwar, V.A.; Chang, S.D.

    2012-01-01

    The purpose of this article is to review and illustrate the spectrum of computed tomography (CT) appearances of abdominal tuberculosis. Tuberculosis can affect any organ or tissue in the abdomen, and can be mistaken for other inflammatory or neoplastic conditions. The most common sites of tuberculosis in the abdomen include lymph nodes, genitourinary tract, peritoneal cavity and gastrointestinal tract. The liver, spleen, biliary tract, pancreas and adrenals are rarely affected, but are more likely in HIV-seropositive patients and in miliary tuberculosis. This article should alert the radiologist to consider abdominal tuberculosis in the correct clinical setting to ensure timely diagnosis and enable appropriate treatment.

  9. The Role of Computed Tomography in Blunt Abdominal Trauma

    Directory of Open Access Journals (Sweden)

    Om Bahadur Karki

    2016-10-01

    aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. Methods: A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Results: Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traf c accident (47.5% was the most common mechanism of injury. Spleen (27.5% was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% speci city 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, speci city 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. Conclusion: In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan. Keywords: blunt abdominal trauma; CT scan; FAST scan; road traf c accident.

  10. Oral contrast for CT in patients with acute non-traumatic abdominal and pelvic pain: what should be its current role?

    Science.gov (United States)

    Kielar, Ania Z; Patlas, Michael N; Katz, Douglas S

    2016-10-01

    Positive oral contrast agents, including barium suspensions and water-soluble iodinated solutions, have traditionally been used in conjunction with the CT evaluation of patients with abdominal and pelvic pain. Due to continued advancements in CT technology, and due to increasing obesity and correspondingly a general increase in the intra-abdominal and intra-pelvic fat separating bowel loops in North American patients and in patients in other parts of the world over the past few decades, the ability of radiologists to accurately evaluate the cause of acute symptoms has substantially improved. Recent research and evolving imaging society guidelines/systematic reviews increasingly support performing CT scans of the abdomen and pelvis without the need for positive oral contrast in these types of adult patient populations, in most clinical situations. Increased patient throughput, patient preference, patient safety, and most importantly, retention of high diagnostic accuracy, are reasons for this recent change in practice to routinely omit the use of enteric contrast agents for the majority of patients presenting with acute abdominal and pelvic pain whom are undergoing emergency CT.

  11. Predicting hollow viscus injury in blunt abdominal trauma with computed tomography.

    Science.gov (United States)

    Bhagvan, Savitha; Turai, Matthew; Holden, Andrew; Ng, Alexander; Civil, Ian

    2013-01-01

    Evaluation of blunt abdominal trauma is controversial. Computed tomography (CT) of the abdomen is commonly used but has limitations, especially in excluding hollow viscus injury in the presence of solid organ injury. To determine whether CT reports alone could be used to direct operative treatment in abdominal trauma, this study was undertaken. The trauma database at Auckland City Hospital was accessed for patients who had abdominal CT and subsequent laparotomy during a five-year period. The CT scans were reevaluated by a consultant radiologist who was blinded to operative findings. The CT findings were correlated with the operative findings. Between January 2002 and December 2007, 1,250 patients were evaluated for blunt abdominal injury with CT. A subset of 78 patients underwent laparotomy, and this formed the study group. The sensitivity and specificity of CT scan in predicting hollow viscus injury was 55.33 and 92.06 % respectively. The positive and negative predictive values were 61.53 and 89.23 % respectively. Presence of free fluid in CT scan was sensitive in diagnosing hollow viscus injury (90 %). Specific findings for hollow viscus injuries on CT scan were free intraperitoneal air (93 %), retroperitoneal air (100 %), oral contrast extravasation (100 %), bowel wall defect (98 %), patchy bowel enhancement (97 %), and mesenteric abnormality (94 %). CT alone cannot be used as a screening tool for hollow viscus injury. The decision to operate in hollow viscus injury has to be based on mechanism of injury and clinical findings together with radiological evidence.

  12. Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review

    International Nuclear Information System (INIS)

    Alshamari, Muhammed; Geijer, Haakan; Norrman, Eva; Geijer, Mats; Jansson, Kjell

    2016-01-01

    Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. Fifty-eight patients were imaged with both methods and were reviewed independently by three radiologists. The reference standard was obtained from the diagnosis in medical records. Sensitivity and specificity were calculated. A systematic review was performed after a literature search, finding a total of six relevant studies including the present. Overall sensitivity with 95 % CI for CT was 75 % (66-83 %) and 46 % (37-56 %) for radiography. Specificity was 87 % (77-94 %) for both methods. In the systematic review the overall sensitivity for CT varied between 75 and 96 % with specificity from 83 to 95 % while the overall sensitivity for abdominal radiography varied between 30 and 77 % with specificity 75 to 88 %. Based on the current study and available evidence, low-dose CT has higher diagnostic accuracy than abdominal radiography and it should, where logistically possible, replace abdominal radiography in the workup of adult patients with acute non-traumatic abdominal pain. (orig.)

  13. Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Alshamari, Muhammed; Geijer, Haakan [Oerebro University, Department of Radiology, Faculty of Medicine and Health, Oerebro (Sweden); Norrman, Eva [Oerebro University, Department of Medical Physics, Faculty of Medicine and Health, Oerebro (Sweden); Geijer, Mats [Lund University and Skaane University Hospital, Department of Medical Imaging and Physiology, Lund (Sweden); Jansson, Kjell [Oerebro University, Department of Surgery, Faculty of Medicine and Health, Oerebro (Sweden)

    2016-06-15

    Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. Fifty-eight patients were imaged with both methods and were reviewed independently by three radiologists. The reference standard was obtained from the diagnosis in medical records. Sensitivity and specificity were calculated. A systematic review was performed after a literature search, finding a total of six relevant studies including the present. Overall sensitivity with 95 % CI for CT was 75 % (66-83 %) and 46 % (37-56 %) for radiography. Specificity was 87 % (77-94 %) for both methods. In the systematic review the overall sensitivity for CT varied between 75 and 96 % with specificity from 83 to 95 % while the overall sensitivity for abdominal radiography varied between 30 and 77 % with specificity 75 to 88 %. Based on the current study and available evidence, low-dose CT has higher diagnostic accuracy than abdominal radiography and it should, where logistically possible, replace abdominal radiography in the workup of adult patients with acute non-traumatic abdominal pain. (orig.)

  14. CT findings of benign omental lesions following abdominal cancer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Yun; Kim, Dong Won; Cho, Jin Han; Kwon, Hee Jin; Ha, Dong Ho; Oh, Jong Young [Diagnostic Radiology, Dong-A University College of Medicine, Busan (Korea, Republic of)

    2016-07-15

    The greater omentum is the largest peritoneal fold and can be the origin of primary pathologic conditions, as well as a boundary and conduit for disease processes. Most diseases involving the omentum manifest with nonspecific and overlapping features on computed tomography (CT). In particular, varying benign disease processes of traumatic, inflammatory, vascular, or systemic origin can occur in the omentum during the follow-up period after surgery for intra-abdominal malignancy. It can be challenging for radiologists due to various spectrum of CT findings. Thus, we reviewed the CT findings of various benign omental lesions after surgery for intra-abdominal malignancy.

  15. CT identification of abdominal injuries in abused pre-school-age children

    International Nuclear Information System (INIS)

    Hilmes, Melissa A.; Hernanz-Schulman, Marta; Kan, J.H.; Greeley, Christopher S.; Piercey, Lisa M.; Yu, Chang

    2011-01-01

    Although the abdominopelvic CT findings of abdominal trauma in children have been described, little has been written about the subset of children who are victims of abuse. Our purpose is to describe abdominopelvic injuries in abused pre-school-age children as identified on CT. An IRB-approved retrospective review of our institutional child abuse registry was performed. Searching a 14-year period, we identified 84 children ≤ 5 years of age with medically diagnosed abuse who underwent CT. We reviewed imaging studies, operative reports, autopsy findings and patient outcomes. Consensus review of the CT examinations was performed by CAQ-certified pediatric radiologists, and findings were categorized as normal or by injury types (solid organ versus bowel). The injuries were analyzed in light of existing literature on pediatric accidental and non-accidental injuries. Of the 84 children, 35 (41.7%) had abdominal injuries. Abdominal injuries included liver (15), bowel (13), mesentery (4), spleen (6), kidneys (7), pancreas (4) and adrenal glands (3). Of these children, 26% (9/35) required surgical intervention for bowel, mesenteric and pancreatic injuries. Another 9/35 children died, not as a result of abdominal injuries but as a direct result of inflicted intracranial injuries. Our data indicate that abdominal injuries in abused children present in a pattern similar to that of children with accidental abdominal trauma, underscoring the need for vigilance and correlative historical and clinical data to identify victims of abuse. Mortality in abused children with intra-abdominal injury was frequently related to concomitant head injury. (orig.)

  16. CT identification of abdominal injuries in abused pre-school-age children

    Energy Technology Data Exchange (ETDEWEB)

    Hilmes, Melissa A.; Hernanz-Schulman, Marta; Kan, J.H. [Vanderbilt Children' s Hospital, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Greeley, Christopher S. [University of Texas Health Science Center at Houston, Department of Pediatrics, Houston, TX (United States); Piercey, Lisa M. [Vanderbilt Children' s Hospital, Department of Pediatrics, Nashville, TN (United States); Yu, Chang [Vanderbilt University, Department of Biostatistics, Nashville, TN (United States)

    2011-05-15

    Although the abdominopelvic CT findings of abdominal trauma in children have been described, little has been written about the subset of children who are victims of abuse. Our purpose is to describe abdominopelvic injuries in abused pre-school-age children as identified on CT. An IRB-approved retrospective review of our institutional child abuse registry was performed. Searching a 14-year period, we identified 84 children {<=} 5 years of age with medically diagnosed abuse who underwent CT. We reviewed imaging studies, operative reports, autopsy findings and patient outcomes. Consensus review of the CT examinations was performed by CAQ-certified pediatric radiologists, and findings were categorized as normal or by injury types (solid organ versus bowel). The injuries were analyzed in light of existing literature on pediatric accidental and non-accidental injuries. Of the 84 children, 35 (41.7%) had abdominal injuries. Abdominal injuries included liver (15), bowel (13), mesentery (4), spleen (6), kidneys (7), pancreas (4) and adrenal glands (3). Of these children, 26% (9/35) required surgical intervention for bowel, mesenteric and pancreatic injuries. Another 9/35 children died, not as a result of abdominal injuries but as a direct result of inflicted intracranial injuries. Our data indicate that abdominal injuries in abused children present in a pattern similar to that of children with accidental abdominal trauma, underscoring the need for vigilance and correlative historical and clinical data to identify victims of abuse. Mortality in abused children with intra-abdominal injury was frequently related to concomitant head injury. (orig.)

  17. CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections

    International Nuclear Information System (INIS)

    Marano, I.; Mainenti, P.P.; Selva, G.; Cannavale, M.; Sodano, A.

    1999-01-01

    The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections [it

  18. ORIGINAL ARTICLE ORIG ORIG CT for upper abdominal pathology ...

    African Journals Online (AJOL)

    ORIG. 14. SA JOURNAL OF RADIOLOGY • March 2007. ORIG. Abstract. Background. Current practice at our institution for routine abdominal. CT includes coverage from the diaphragm to the symphysis pubis and therefore includes pelvic organs. Limited upper abdominal imaging exists in other modalities, and tailoring the ...

  19. Computed Tomography (CT) Imaging of Injuries from Blunt Abdominal Trauma: A Pictorial Essay

    OpenAIRE

    Hassan, Radhiana; Abd. Aziz, Azian

    2010-01-01

    Blunt abdominal trauma can cause multiple internal injuries. However, these injuries are often difficult to accurately evaluate, particularly in the presence of more obvious external injuries. Computed tomography (CT) imaging is currently used to assess clinically stable patients with blunt abdominal trauma. CT can provide a rapid and accurate appraisal of the abdominal viscera, retroperitoneum and abdominal wall, as well as a limited assessment of the lower thoracic region and bony pelvis. T...

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... tomography (CT) scan View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. ...

  1. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  2. Short- and long-term effects of clinical audits on compliance with procedures in CT scanning

    International Nuclear Information System (INIS)

    Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2016-01-01

    To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific ''paediatric brain CT'' procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from <0.001 to 0.031) in both hospitals and remained unchanged during the third audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. (orig.)

  3. Comparison of radiation doses between newborns and 6-y-old children undergoing head, chest and abdominal CT examinations-A phantom study

    International Nuclear Information System (INIS)

    Sugimoto, N.; Aoyama, T.; Koyama, S.; Yamauchi-Kawaura, C.; Fujii, K.

    2013-01-01

    Radiation doses in paediatric computed tomography (CT) were investigated for various types of recent CT scanners with newborn and 6-y-old phantoms in which silicon-photodiode dosemeters were implanted at various organ positions. In the head, chest and abdominal CT for the newborn phantom, doses for organs within the scan region were 21-40, 3-8 and 3-12 mGy, respectively. The corresponding doses for the child phantom were 20-37, 2-11 and 4-17 mGy, respectively. In the head, chest and abdominal CT, the effective doses were respectively 2.1-3.3, 2.0-6.0 and 2.2-10.0 mSv for the newborn, and 1.0-2.0, 1.2-6.6 and 2.9-11.8 mSv for the child. Radiation doses for the newborn were at the same levels as those for the child, excepting effective doses in head CT for the newborn, which were 1.8 times higher than those for the child. (authors)

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... in CT scans should have no immediate side effects. Risks There is always a slight chance of cancer from excessive exposure to radiation. However, the benefit of an accurate ...

  5. Systematic radiation dose optimization of abdominal dual-energy CT on a second-generation dual-source CT scanner: assessment of the accuracy of iodine uptake measurement and image quality in an in vitro and in vivo investigations.

    Science.gov (United States)

    Schindera, Sebastian T; Zaehringer, Caroline; D'Errico, Luigia; Schwartz, Fides; Kekelidze, Maka; Szucs-Farkas, Zsolt; Benz, Matthias R

    2017-10-01

    To assess the accuracy of iodine quantification in a phantom study at different radiation dose levels with dual-energy dual-source CT and to evaluate image quality and radiation doses in patients undergoing a single-energy and two dual-energy abdominal CT protocols. In a phantom study, the accuracy of iodine quantification (4.5-23.5 mgI/mL) was evaluated using the manufacturer-recommended and three dose-optimized dual-energy protocols. In a patient study, 75 abdomino-pelvic CT examinations were acquired as follows: 25 CT scans with the manufacturer-recommended dual-energy protocol (protocol A); 25 CT scans with a dose-optimized dual-energy protocol (protocol B); and 25 CT scans with a single-energy CT protocol (protocol C). CTDI vol and objective noise were measured. Five readers scored each scan according to six subjective image quality parameters (noise, contrast, artifacts, visibility of small structures, sharpness, overall diagnostic confidence). In the phantom study, differences between the real and measured iodine concentrations ranged from -8.8% to 17.0% for the manufacturer-recommended protocol and from -1.6% to 20.5% for three dose-optimized protocols. In the patient study, the CTDI vol of protocol A, B, and C were 12.5 ± 1.9, 7.5 ± 1.2, and 6.5 ± 1.7 mGycm, respectively (p dual-energy and the single-energy protocol. A dose reduction of 41% is feasible for the manufacturer-recommended, abdominal dual-energy CT protocol, as it maintained the accuracy of iodine measurements and subjective image quality compared to a single-energy protocol.

  6. A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

    Science.gov (United States)

    Paganelli, Chiara; Summers, Paul; Gianoli, Chiara; Bellomi, Massimo; Baroni, Guido; Riboldi, Marco

    2017-11-01

    Dynamic magnetic resonance imaging (MRI) is emerging as the elected image modality for organ motion quantification and management in image-guided radiotherapy. However, the lack of validation tools is an open issue for image guidance in the abdominal and thoracic organs affected by organ motion due to respiration. We therefore present an abdominal four-dimensional (4D) CT/MRI digital phantom, including the estimation of MR tissue parameters, simulation of dedicated abdominal MR sequences, modeling of radiofrequency coil response and noise, followed by k-space sampling and image reconstruction. The phantom allows the realistic simulation of images generated by MR pulse sequences with control of scan and tissue parameters, combined with co-registered CT images. In order to demonstrate the potential of the phantom in a clinical scenario, we describe the validation of a virtual T1-weighted 4D MRI strategy. Specifically, the motion extracted from a T2-weighted 4D MRI is used to warp a T1-weighted breath-hold acquisition, with the aim of overcoming trade-offs that limit T1-weighted acquisitions. Such an application shows the applicability of the digital CT/MRI phantom as a validation tool, which should be especially useful for cases unsuited to obtain real imaging data.

  7. Abdominal wall hernias: imaging with spiral CT

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G.

    2000-01-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  8. Abdominal and Pelvic CT

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  9. Abdominal fat-evaluation by use of single scan computed tomography

    International Nuclear Information System (INIS)

    Jacobi, V.; Steinkamp, M.; Kirchner, J.; Fischer, H.; Diedrich, C.F.; Kollath, J.

    1997-01-01

    Purpose: Several studies emphasised the importance of the relationship between intraabdominal and total body adipose tissue as a risk factor for the development of metabolic or cardiovascular diseases. Therefore, the aim of the present study was to examine whether a single scan computed tomography is able to determine the whole intraabdominal fat volume with high accuracy and reproducibility. Materials and methods: Regions of interests (ROIs) were drawn manually for measuring intraabdominal fat in 51 unsuspicious abdominal CT. Results: The sexual differentiation of adipose tissue already described in a lot of studies could be confirmed in this study. Fat still predominates in females in lower half of the body (gynoid obesity). In men it predominates in the upper half (android obesity). Significant correlation concerning measuring the whole intraabdominal fat volume could be found in L1-level in women (r=0.992) and in L2-level in men (r=0.992). Measurement of a single scan enables us to assess whole intraabdominal fat volume due to a special formula. Conclusion: The determination of intraabdominal fat measured by a single scan computed tomography is a procedure associated with high accuracy and reproducibility. (orig.) [de

  10. Assessing the prevalence and clinical relevance of positive abdominal and pelvic CT findings in senior patients presenting to the emergency department.

    Science.gov (United States)

    Alabousi, Abdullah; Patlas, Michael N; Meshki, Malek; Monteiro, Sandra; Katz, Douglas S

    2016-04-01

    The purpose of our study was to retrospectively evaluate the prevalence and clinical relevance of positive abdominal and pelvic CT findings for patients 65 years of age and older, when compared with all other scanned adult Emergency Department (ED) patients, at a single tertiary care hospital. Our hypothesis was that there is an increased prevalence and clinical relevance of positive abdominal/pelvic CT findings in senior patients. A research ethics board-approved retrospective review of all adult patients who underwent an emergency CT of the abdomen and pelvis for acute nontraumatic abdominal and/or pelvic signs and symptoms was performed. Two thousand one hundred two patients between October 1, 2011, and September 30, 2013, were reviewed. Six hundred thirty-one patients were included in the 65 group (209 men and 253 women; mean age 77.6, age range 65-99). Overall, there were more positive CT findings for patients 65 group (257 positive cases, 55.6 %), which was a statistically significant difference (p 65 group, there were no statistically significant differences in the clinical/surgical relevance of the positive CT findings between the two groups. The findings of our retrospective study therefore refute our hypothesis that there is an increased prevalence of positive abdominal CT findings in patients >65. This may be related to ED physicians at our institution being more hesitant to order CT examinations for the younger population, presumably due to radiation concerns. However, older patients in our series were more likely to present with complicated appendicitis, and a lower threshold for ordering CT examinations of the abdomen and pelvis in this patient population should therefore be considered.

  11. Short- and long-term effects of clinical audits on compliance with procedures in CT scanning.

    Science.gov (United States)

    Oliveri, Antonio; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2016-08-01

    To test the hypothesis that quality clinical audits improve compliance with the procedures in computed tomography (CT) scanning. This retrospective study was conducted in two hospitals, based on 6950 examinations and four procedures, focusing on the acquisition length in lumbar spine CT, the default tube current applied in abdominal un-enhanced CT, the tube potential selection for portal phase abdominal CT and the use of a specific "paediatric brain CT" procedure. The first clinical audit reported compliance with these procedures. After presenting the results to the stakeholders, a second audit was conducted to measure the impact of this information on compliance and was repeated the next year. Comparisons of proportions were performed using the Chi-square Pearson test. Depending on the procedure, the compliance rate ranged from 27 to 88 % during the first audit. After presentation of the audit results to the stakeholders, the compliance rate ranged from 68 to 93 % and was significantly improved for all procedures (P ranging from audit (P ranging from 0.114 to 0.999). Quality improvement through repeated compliance audits with CT procedures durably improves this compliance. • Compliance with CT procedures is operator-dependent and not perfect. • Compliance differs between procedures and hospitals, even within a unified department. • Compliance is improved through audits followed by communication to the stakeholders. • This improvement is sustainable over a one-year period.

  12. Percutaneous Transhepatic Drainage of Inaccessible Abdominal Abscesses Following Abdominal Surgery Under Real-Time CT-Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Nakatsuka, Atsuhiro; Kashima, Masataka; Uraki, Junji; Yamanaka, Takashi; Takeda, Kan

    2010-01-01

    This study evaluated the safety, feasibility, and clinical utility of transhepatic drainage of inaccessible abdominal abscesses retrospectively under real-time computed tomographic (CT) guidance. For abdominal abscesses, 12 consecutive patients received percutaneous transhepatic drainage. Abscesses were considered inaccessible using the usual access route because they were surrounded by the liver and other organs. The maximum diameters of abscesses were 4.6-9.5 cm (mean, 6.7 ± 1.4 cm). An 8-Fr catheter was advanced into the abscess cavity through the liver parenchyma using real-time CT fluoroscopic guidance. Safety, feasibility, procedure time, and clinical utility were evaluated. Drainage catheters were placed with no complications in abscess cavities through the liver parenchyma in all patients. The mean procedure time was 18.8 ± 9.2 min (range, 12-41 min). All abscesses were drained. They shrank immediately after catheter placement. In conclusions, this transhepatic approach under real-time CT fluoroscopic guidance is a safe, feasible, and useful technique for use of drainage of inaccessible abdominal abscesses.

  13. The Role of Computed Tomography in Blunt Abdominal Trauma.

    Science.gov (United States)

    Karki, O B

    2015-01-01

    Blunt injury trauma is regularly encountered in the emergency department. Diagnostic tools that help in optimum management of blunt abdominal trauma include; Focussed Assessment Sonography for Trauma scan, Diagnostic peritoneal lavage and Computed Tomography scan. The aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traffic accident (47.5%) was the most common mechanism of injury. Spleen (27.5%) was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% specificity 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, specificity 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan.

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you’re taking, and allergies. You ... a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple ...

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... treatments. plan for and assess the results of surgery, such as organ transplants. stage, plan and properly ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. No radiation remains in a ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... liver, shows up in shades of gray, and air appears black. With CT scanning, numerous x-ray ... cause blurring of the images and degrade the quality of the examination the same way that it ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... for tumors as well as monitor response to chemotherapy. top of page How should I prepare? You ... over time. top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... infections such as appendicitis , pyelonephritis or infected fluid collections, also known as abscesses. inflammatory bowel disease such ... by a burst appendix or an infected fluid collection and the subsequent spread of infection. CT scanning ...

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... entire body will be "inside" the scanner at one time such as with MRI. If an intravenous ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... up in shades of gray, and air appears black. With CT scanning, numerous x-ray beams and ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. Manufacturers of intravenous contrast indicate mothers ... necessary. CT scans in children should always be done with low-dose technique. Radiology departments tailor the ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... painless, noninvasive and accurate. In emergency cases, it can reveal internal injuries and bleeding quickly enough to ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... the internal organs, small bowel and colon, such as: infections such as appendicitis , pyelonephritis or infected fluid ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... See the Safety page for more information about pregnancy and x-rays. top of page What does ... See the Safety page for more information about pregnancy and x-rays. CT scanning is, in general, ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... deal with them. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  9. [Automated detection and volumetric segmentation of the spleen in CT scans].

    Science.gov (United States)

    Hammon, M; Dankerl, P; Kramer, M; Seifert, S; Tsymbal, A; Costa, M J; Janka, R; Uder, M; Cavallaro, A

    2012-08-01

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like "marginal space learning" and "boosting algorithms". 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm³ + 0.58 (width × length × thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 (± 2.4) seconds. The average splenic volume measured by aV was 268.21 ± 114.67 cm³ compared to 281.58 ± 130.21 cm³ in mV and 268.93 ± 104.60 cm³ in eV. The correlation coefficient was 0.99 (coefficient of determination (R²) = 0.98) for aV and mV, 0.91 (R² = 0.83) for mV and eV and 0.91 (R² = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R² = 0.84), mV and eV (0.95; R² = 0.91) and aV and eV (0.83; R² = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Automated detection and volumetric segmentation of the spleen in CT scans

    International Nuclear Information System (INIS)

    Hammon, M.; Dankerl, P.; Janka, R.; Uder, M.; Cavallaro, A.; Kramer, M.; Seifert, S.; Tsymbal, A.; Costa, M.J.

    2012-01-01

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like ''marginal space learning'' and ''boosting algorithms''. 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm 3 + 0.58 (width x length x thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 (± 2.4) seconds. The average splenic volume measured by aV was 268.21 ± 114.67 cm 3 compared to 281.58 ± 130.21 cm 3 in mV and 268.93 ± 104.60 cm 3 in eV. The correlation coefficient was 0.99 (coefficient of determination (R 2 ) = 0.98) for aV and mV, 0.91 (R 2 = 0.83) for mV and eV and 0.91 (R 2 = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R 2 = 0.84), mV and eV (0.95; R 2 = 0.91) and aV and eV (0.83; R 2 = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. (orig.)

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ... us improve RadiologyInfo.org by taking our brief survey: Survey Do you have a personal story about ...

  12. Benign hepatic portal venous gas following blunt abdominal trauma

    International Nuclear Information System (INIS)

    Dill-Mackay, M.J.

    1997-01-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure

  13. Benign hepatic portal venous gas following blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Dill-Mackay, M.J. [Royal Perth Hospital, Perth, WA (Australia). Department of Radiology

    1997-05-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure. 20 refs., 1 tab., 2 figs.

  14. Detection of abdominal lymph node metastases from esophageal and cardia cancer by computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shima, S; Sugiura, Y; Yonekawa, H; Ogata, T [National Defence Medical Coll., Tokorosawa, Saitama (Japan)

    1982-03-01

    In order to evaluate the sensitivity of computed tomography (CT) scan in detecting the abdominal lymph node metastases, preoperative CT scan was performed in 16 patients with carcinoma of the esophagus and gastric cardia. Ten patients (62.5%) had pathological evidence of lymph node metastases in the abdominal cavity and 4 of them were identified to involve the para-aortic nodes. CT scan correctly demonstrated the lymph node metastases in the para-aortic and celiac axisis areas, but failed to detect other abdominal lymph node involvements, which were small enough to be excised by operation. The para-aortic nodes on the CT scan showed the following two features; one was nodular mass in shape, which did not obscure the aorta or inferior vena cava, and the other was conglomerated mass, which was difficult to be distinguished from the aorta. The former was resectable and the latter was not.

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... its ability to image bone, soft tissue and blood vessels all at the same time. Unlike conventional x-rays, CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  16. Validity of a new abdominal bioelectrical impedance device to measure abdominal and visceral fat: comparison with MRI

    OpenAIRE

    Browning, Lucy M; Mugridge, Owen; Chatfield, Mark; Dixon, Adrian; Aitken, Sri; Joubert, Ilse; Prentice, Andrew M.; Jebb, Susan A

    2010-01-01

    Abdominal fat, and in particular, visceral adipose tissue (VAT), is the critical fat depot associated with metabolic aberrations. At present VAT can only be accurately measured by computed tomography (CT) or magnetic resonance imaging (MRI). This study was designed to compare a new abdominal bioelectrical impedance device against total abdominal adipose tissue (TAAT) and VAT area measurements made from an abdominal MRI scan, and to assess it’s reliability and accuracy.

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist can ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  18. A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant

    Energy Technology Data Exchange (ETDEWEB)

    Kilincer, Abidin; Akpinar, Erhan; Uenal, Emre; Karaosmanoglu, Ali Devrim; Akata, Deniz; Oezmen, Mustafa [Hacettepe University Faculty of Medicine, Department of Radiology, Sihhiye, Ankara (Turkey); Erbil, Buelent [Hacettepe University Faculty of Medicine, Department of Emergency Medicine, Ankara (Turkey); Kaynaroglu, Volkan [Hacettepe University Faculty of Medicine, Department of General Surgery, Ankara (Turkey)

    2017-08-15

    To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. 168 patients (age range, 18-78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher's and Pearson's chi-squared tests were used for statistical analysis. There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P < 0.01) in patients without appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. (orig.)

  19. A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant

    International Nuclear Information System (INIS)

    Kilincer, Abidin; Akpinar, Erhan; Uenal, Emre; Karaosmanoglu, Ali Devrim; Akata, Deniz; Oezmen, Mustafa; Erbil, Buelent; Kaynaroglu, Volkan

    2017-01-01

    To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. 168 patients (age range, 18-78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher's and Pearson's chi-squared tests were used for statistical analysis. There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P < 0.01) in patients without appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. (orig.)

  20. Diffuse cystic peritoneal lymphangiomatosis. Long-term clinical, ultrasonographic and CT scan study in one case

    International Nuclear Information System (INIS)

    Berry, M.; Paillot, B.; Monneins, F.; Delafolie, A.; Guyet-Rousset, P.

    1987-01-01

    An adult male with episodic manifestations of abdominal lymphangiomatosis has been followed up over a 5 year period. This prolonged surveillance of clinical features combined with ultrasound and CT scan imaging has no doubt contributed to improved knowledge of diagnostic and physiopathologic factors of these rare lesions. The particular behavior of the case reported evokes discussion on the conventional surgical treatment of lymphangioma [fr

  1. Original Research Intra-abdominal fat: Comparison of computed ...

    African Journals Online (AJOL)

    advantage for composition measurement of no radiation exposure ... Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with .... spiral CT scan with 3-mm slices covering the abdomen,.

  2. Unsupervised quantification of abdominal fat from CT images using Greedy Snakes

    Science.gov (United States)

    Agarwal, Chirag; Dallal, Ahmed H.; Arbabshirani, Mohammad R.; Patel, Aalpen; Moore, Gregory

    2017-02-01

    Adipose tissue has been associated with adverse consequences of obesity. Total adipose tissue (TAT) is divided into subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT). Intra-abdominal fat (VAT), located inside the abdominal cavity, is a major factor for the classic obesity related pathologies. Since direct measurement of visceral and subcutaneous fat is not trivial, substitute metrics like waist circumference (WC) and body mass index (BMI) are used in clinical settings to quantify obesity. Abdominal fat can be assessed effectively using CT or MRI, but manual fat segmentation is rather subjective and time-consuming. Hence, an automatic and accurate quantification tool for abdominal fat is needed. The goal of this study is to extract TAT, VAT and SAT fat from abdominal CT in a fully automated unsupervised fashion using energy minimization techniques. We applied a four step framework consisting of 1) initial body contour estimation, 2) approximation of the body contour, 3) estimation of inner abdominal contour using Greedy Snakes algorithm, and 4) voting, to segment the subcutaneous and visceral fat. We validated our algorithm on 952 clinical abdominal CT images (from 476 patients with a very wide BMI range) collected from various radiology departments of Geisinger Health System. To our knowledge, this is the first study of its kind on such a large and diverse clinical dataset. Our algorithm obtained a 3.4% error for VAT segmentation compared to manual segmentation. These personalized and accurate measurements of fat can complement traditional population health driven obesity metrics such as BMI and WC.

  3. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  4. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... pancreatic, uterine or ovarian abnormalities, the evaluation and diagnosis with MRI may be preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation Therapy for Colorectal Cancer top of page ...

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... shield may stay in the room with their child. However, the technologist will always be able to ...

  9. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... conditions may increase the risk of an unusual adverse effect. Women should always inform their physician and the ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. ... immediate side effects. Risks There is always a slight chance of ...

  11. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging

    International Nuclear Information System (INIS)

    Balter, James M.; Lam, Kwok L.; McGinn, Cornealeus J.; Lawrence, Theodore S.; Haken, Randall K. ten

    1998-01-01

    Purpose: CT-based models of the patient that do not account for the motion of ventilation may not accurately predict the shape and position of critical abdominal structures. Respiratory gating technology for imaging and treatment is not yet widely available. The purpose of the current study is to explore an intermediate step to improve the veracity of the patient model and reduce the treated volume by acquiring the CT data with the patients holding their breath at normal exhale. Methods and Materials: The ventilatory time courses of diaphragm movement for 15 patients (with no special breathing instructions) were measured using digitized movies from the fluoroscope during simulation. A subsequent clinical protocol was developed for treatment based on exhale CT models. CT scans (typically 3.5-mm slice thickness) were acquired at normal exhale using a spiral scanner. The scan volume was divided into two to three segments, to allow the patient to breathe in between. Margins were placed about intrahepatic target volumes based on the ventilatory excursion inferior to the target, and on only the reproducibility of exhale position superior to the target. Results: The average patient's diaphragm remained within 25% of the range of ventilatory excursion from the average exhale position for 42% of the typical breathing cycle, and within 25% of the range from the average inhale position for 15% of the cycle. The reproducibility of exhale position over multiple breathing cycles was 0.9 mm (2σ), as opposed to 2.6 mm for inhale. Combining the variation of exhale position and the uncertainty in diaphragm position from CT slices led to typical margins of 10 mm superior to the target, and 19 mm inferior to the target, compared to margins of 19 mm in both directions under our prior protocol of margins based on free-breathing CT studies. For a typical intrahepatic target, these smaller volumes resulted in a 3.6% reduction in V eff for the liver. Analysis of portal films shows proper

  12. Abdominal tuberculosis. On-going challenge to gastroenterologists

    International Nuclear Information System (INIS)

    Ibrahim, Mahgoub; Osuba, Abimbola

    2005-01-01

    The aim of this study is to record the observations and experience on the diagnosis and management of abdominal tuberculosis (TB) and to highlight the difficulties in the diagnosis and management of this condition. Two hundred consecutive patients attending the Gastroenterology Department of the King Khalid National Guard Hospital, Jeddah, Kingdom of Saudi Arabia between May 1991 and May 2001, suspected with abdominal TB were investigated. A detailed clinical history and physical examination were obtained. Data of 75 confirmed cases of abdominal TB were analyzed. The most common presenting symptoms were anorexia (84%), abdominal pain (84%) and weight loss (72%). Abdominal tenderness was the most common clinical finding, followed by ascites and abdominal mass (42%). The chest radiograph suggestive of pulmonary TB was diagnosed in 24 patients (32%). Computed tomographic (CT) scanning revealed abnormalities in all 51 patients who underwent the procedure, while positive findings were observed by abdominal ultrasound in 66% of the tested patients. Histopathological examination of patients showed tuberculosis granuloma, while acid fast bacilli were seen in 34%. Mycobacterium tuberculosis was identified by microbiological methods in 60% of patients. The most common presenting symptoms were anorexia (84%), abdominal pain (84%) and weight loss (72%). Abdominal tenderness was the most common clinical finding, followed by ascites and abdominal mass (42%). The chest radiograph suggestive of pulmonary TB was diagnosed in 24 patients (32%). Computed tomographic (CT) scanning revealed abnormalities in all 51 patients who underwent the procedure, while positive findings were observed by abdominal ultrasound in 66% of the tested patients. Histopathological examination of patients showed tuberculous granuloma, while acid fast bacilli were seen in 34%. Mycobacterium tuberculosis was identified by microbiological methods in 60% of patients. A high index of clinical suspicion is

  13. Abdominal and pelvic computed tomography (CT) interpretation: discrepancy rates among experienced radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Abujudeh, Hani H.; Boland, Giles W.; Kaewlai, Rathachai; Rabiner, Pavel; Thrall, James H. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Halpern, Elkarn F.; Gazelle, G.S. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Massachusetts General Hospital and Harvard Medical School, Institute for Technology Assessment, Boston, MA (United States)

    2010-08-15

    To assess the discrepancy rate for the interpretation of abdominal and pelvic computed tomography (CT) examinations among experienced radiologists. Ninety abdominal and pelvic CT examinations reported by three experienced radiologists who specialize in abdominal imaging were randomly selected from the radiological database. The same radiologists, blinded to previous interpretation, were asked to re-interpret 60 examinations: 30 of their previous interpretations and 30 interpreted by others. All reports were assessed for the degree of discrepancy between initial and repeat interpretations according to a three-level scoring system: no discrepancy, minor, or major discrepancy. Inter- and intrareader discrepancy rates and causes were evaluated. CT examinations included in the investigation were performed on 90 patients (43 men, mean age 59 years, SD 14, range 19-88) for the following indications: follow-up/evaluation of malignancy (69/90, 77%), pancreatitis (5/90, 6%), urinary tract stone (4/90, 4%) or other (12/90, 13%). Interobserver and intraobserver major discrepancy rates were 26 and 32%, respectively. Major discrepancies were due to missed findings, different opinions regarding interval change of clinically significant findings, and the presence of recommendation. Major discrepancy of between 26 and 32% was observed in the interpretation of abdominal and pelvic CT examinations. (orig.)

  14. Abdominal and pelvic computed tomography (CT) interpretation: discrepancy rates among experienced radiologists

    International Nuclear Information System (INIS)

    Abujudeh, Hani H.; Boland, Giles W.; Kaewlai, Rathachai; Rabiner, Pavel; Thrall, James H.; Halpern, Elkarn F.; Gazelle, G.S.

    2010-01-01

    To assess the discrepancy rate for the interpretation of abdominal and pelvic computed tomography (CT) examinations among experienced radiologists. Ninety abdominal and pelvic CT examinations reported by three experienced radiologists who specialize in abdominal imaging were randomly selected from the radiological database. The same radiologists, blinded to previous interpretation, were asked to re-interpret 60 examinations: 30 of their previous interpretations and 30 interpreted by others. All reports were assessed for the degree of discrepancy between initial and repeat interpretations according to a three-level scoring system: no discrepancy, minor, or major discrepancy. Inter- and intrareader discrepancy rates and causes were evaluated. CT examinations included in the investigation were performed on 90 patients (43 men, mean age 59 years, SD 14, range 19-88) for the following indications: follow-up/evaluation of malignancy (69/90, 77%), pancreatitis (5/90, 6%), urinary tract stone (4/90, 4%) or other (12/90, 13%). Interobserver and intraobserver major discrepancy rates were 26 and 32%, respectively. Major discrepancies were due to missed findings, different opinions regarding interval change of clinically significant findings, and the presence of recommendation. Major discrepancy of between 26 and 32% was observed in the interpretation of abdominal and pelvic CT examinations. (orig.)

  15. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... operates the scanner and monitors your examination in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... to help detect diseases of the small bowel, colon and other internal organs and is often used to determine the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it can reveal internal injuries and bleeding quickly enough to help save lives. ...

  18. Ct enterography/ct abdomen and pelvis using neutral oral contrast. a new combination of natural products

    International Nuclear Information System (INIS)

    Aslam, M.O.

    2014-01-01

    Our purpose was to assess the performance of a new combination of neutral oral contrast for CT abdomen and CT Enterography in comparison with commercially available neutral oral contrast VoLumen. Seventy three consecutive patients were given sorbitol/CMC (Carboxy Methyl Cellulose) solution or VoLumen as oral contrast agent for abdominal computed tomography (CT) scan. 23 patients were male and 37 females. Age range was between 16 and 67 years. Since the use of CT scan for abdominal pathologies, there was need to separate bowel loops to localize the pathology. Three types of oral contrast can be used in CT-Scan abdomen; Positive, Neutral and negative. The above used contrasts are Neutral contrast these refers to agents that have an attenuation value similar to that of water (0-30 H).Our results show this new combination of Cc and Sorbitol to be equally good as VoLumen, for luminal distension and mural details, in duodenum and jejunum. While better than VoLumen for Ileal distension. (author)

  19. The value of the abdominal radiograph in the assessment of the acute abdomen- work in progress

    International Nuclear Information System (INIS)

    Verma, R.; Kew, J.; Davies, R.P.

    2002-01-01

    Full text: The value of the abdominal radiograph in the assessment of the acute abdomen was evaluated for those patients who also had abdominal ultrasound and/or CT. The value of each modality in patient management is reviewed. Retrospective review of 52 consecutive patients presented to a tertiary hospital emergency department with acute abdominal pain who underwent abdominal radiographs (AXR) and abdominal ultrasound (US) and / or computed tomography (CT) within 24 hours of presentation was undertaken. There were 37 males and 15 females. The mean age was 53 years (range 18-95y). Abdominal radiographs were reviewed by two radiologists.Two patients had two separate admissions one week apart. There were 35 normal abdominal radiographs. 19 studies showed clinically relevant abnormalities. Of the normal group, 14 out of 21 patients had abnormal findings on CT and 8 out of 16 had abnormal US examinations. Of the 19 patients with abnormal AXR, 17 out of 19 patients had abnormal CT and 2 out of 5 had abnormal ultrasound examinations. There were 5 cases where both CT scan and US was performed. The positive and negative predictive value for AXR vs CT scan was 89% and 33% respectively and for AXR vs US scan was 40% and 50% respectively. For patients with normal AXR and abnormal CT, there was only one case (a non calcified abdominal aortic aneurysm) which might have required immediate surgical intervention. The preliminary results suggest that the abnormal radiograph is sensitive in the detection of relevant abnormalities in the acute abdomen in the context of appropriate clinical selection. Both CT and ultrasound provide additional diagnostic accuracy for some indications.A further 50 patients are being reviewed and the combined results will be presented. Copyright (2002) Blackwell Science Pty Ltd

  20. Diagnosis of gynecologic pelvic masses by CT scans

    International Nuclear Information System (INIS)

    Ito, Hisao; Kubo, Atsushi; Takagi, Yaeko; Kinoshita, Fumio; Maekawa, Akira.

    1981-01-01

    Two hundred eighty four patients with gynecologic pelvic masses were evaluated with CT scans. Of the patients, 196 had subsequent surgical determination of abnormalities and pathological proof of diagnosis was obtained. Only these 196 patients were included in this study. The CT scans could provide correct diagnosis in 113 of 114 (99%) patients with benign uterine tumor and in all (100%) patients with either serous cystadenoma or dermoid cyst. However, evaluation of mucinous cystadenoma (44%) and endometriosis cyst (37%) by CT scan has some limitations. It was difficult to differentiate mucinous cystadenoma from ovarian carcinoma, because both lesions had partial multiloculation and solid-like areas in the cyst. The CT findings of endometriosis cyst had similarity with serous cystadenoma, and 5 of 8 patients with this disease were diagnosed as serous cystadenoma. Ovarian fibroma and endometrial cancer were also not determined by CT scans. CT identified 87% of patients with ovarian cancer, while false positive rate of this disease was 38% (8/21). In 6 of 13 patients with both of leiomyoma and ovarian cyst, CT was able to demonstrate ovarian lesions that were overlooked by bimanual examinations. The role of CT scanning in our clinical practice is discussed. (author)

  1. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  2. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  3. A new technique for the diagnosis of acute appendicitis: abdominal CT with compression to the right lower quadrant.

    Science.gov (United States)

    Kılınçer, Abidin; Akpınar, Erhan; Erbil, Bülent; Ünal, Emre; Karaosmanoğlu, Ali Devrim; Kaynaroğlu, Volkan; Akata, Deniz; Özmen, Mustafa

    2017-08-01

    To determine the diagnostic accuracy of abdominal CT with compression to the right lower quadrant (RLQ) in adults with acute appendicitis. 168 patients (age range, 18-78 years) were included who underwent contrast-enhanced CT for suspected appendicitis performed either using compression to the RLQ (n = 71) or a standard protocol (n = 97). Outer diameter of the appendix, appendiceal wall thickening, luminal content and associated findings were evaluated in each patient. Kruskal-Wallis, Fisher's and Pearson's chi-squared tests were used for statistical analysis. There was no significant difference in the mean outer diameter (MOD) between compression CT scans (10.6 ± 1.9 mm) and standard protocol (11.2 ± 2.3 mm) in patients with acute appendicitis (P = 1). MOD was significantly lower in the compression group (5.2 ± 0.8 mm) compared to the standard protocol (6.5 ± 1.1 mm) (P appendicitis. A cut-off value of 6.75 mm for the outer diameter of the appendix was found to be 100% sensitive in the diagnosis of acute appendicitis for both groups. The specificity was higher for compression CT technique (67.7 vs. 94.9%). Normal appendix diameter was significantly smaller in the compression-CT group compared to standard-CT group, increasing diagnostic accuracy of abdominal compression CT. • Normal appendix diameter is significantly smaller in compression CT. • Compression could force contrast material to flow through the appendiceal lumen. • Compression CT may be a CT counterpart of graded compression US.

  4. New scoring system for intra-abdominal injury diagnosis after blunt trauma

    Directory of Open Access Journals (Sweden)

    Shojaee Majid

    2014-02-01

    Full Text Available 【Abstract】Objective: An accurate scoring system for intra-abdominal injury (IAI based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagno- sis of IAI after blunt trauma. Methods: This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT admitted to the emergency department (ED of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chisquare test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β was given based on the contribution of each of them. Scoring system was developed based on the obtained total βof each factor. Results: Altogether 261 patients (80.1% male were enrolled (48 cases of IAI. A 24-point blunt abdominal trauma scoring system (BATSS was developed. Patients were divided into three groups including low (score<8, moderate (8≤score<12 and high risk (score≥12. In high risk group immediate laparotomy should be done, moderate group needs further assessments, and low risk group should be kept under observation. Low risk patients did not show positive CT-scans (specificity 100%. Conversely, all high risk patients had positive CT-scan findings (sensitivity 100%. The receiver operating characteristic curve indicated a close relationship between the results of CT scan and BATSS (sensitivity=99.3%. Conclusion: The present scoring system furnishes a

  5. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique.

    Science.gov (United States)

    Kwon, Heejin; Cho, Jinhan; Oh, Jongyeong; Kim, Dongwon; Cho, Junghyun; Kim, Sanghyun; Lee, Sangyun; Lee, Jihyun

    2015-10-01

    To investigate whether reduced radiation dose abdominal CT images reconstructed with adaptive statistical iterative reconstruction V (ASIR-V) compromise the depiction of clinically competent features when compared with the currently used routine radiation dose CT images reconstructed with ASIR. 27 consecutive patients (mean body mass index: 23.55 kg m(-2) underwent CT of the abdomen at two time points. At the first time point, abdominal CT was scanned at 21.45 noise index levels of automatic current modulation at 120 kV. Images were reconstructed with 40% ASIR, the routine protocol of Dong-A University Hospital. At the second time point, follow-up scans were performed at 30 noise index levels. Images were reconstructed with filtered back projection (FBP), 40% ASIR, 30% ASIR-V, 50% ASIR-V and 70% ASIR-V for the reduced radiation dose. Both quantitative and qualitative analyses of image quality were conducted. The CT dose index was also recorded. At the follow-up study, the mean dose reduction relative to the currently used common radiation dose was 35.37% (range: 19-49%). The overall subjective image quality and diagnostic acceptability of the 50% ASIR-V scores at the reduced radiation dose were nearly identical to those recorded when using the initial routine-dose CT with 40% ASIR. Subjective ratings of the qualitative analysis revealed that of all reduced radiation dose CT series reconstructed, 30% ASIR-V and 50% ASIR-V were associated with higher image quality with lower noise and artefacts as well as good sharpness when compared with 40% ASIR and FBP. However, the sharpness score at 70% ASIR-V was considered to be worse than that at 40% ASIR. Objective image noise for 50% ASIR-V was 34.24% and 46.34% which was lower than 40% ASIR and FBP. Abdominal CT images reconstructed with ASIR-V facilitate radiation dose reductions of to 35% when compared with the ASIR. This study represents the first clinical research experiment to use ASIR-V, the newest version of

  6. CT scan of Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, T; Noguchi, S; Nishitani, H [National Sanatorium of Utano, Kyoto (Japan); Kitano, H; Ikegami, Y

    1981-04-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs.

  7. CT scan of Parkinson's disease

    International Nuclear Information System (INIS)

    Konishi, Tetsuro; Noguchi, Sadako; Nishitani, Hiroshi; Kitano, Haruo; Ikegami, Yoshinori.

    1981-01-01

    In forty-eight patients with Parkinson's disease, we examined the ventricular size and the degree of cortical atrophy which were measured by the photos of CT scan and compared them with their clinical symptoms and side effects of anti-parkinsonian drugs. The ventricular size was expressed as the ventricular ratio which is the percentage of superimposed lateral ventricular area to the white and gray matter area at the slice number 2B of CT scan photos. The degree of the cortical atrophy was expressed as the sulcal numbers which were clearly visualized at the slice number 3B or 4A of CT scan photos. We used the CT scan photos of age-matched other patients which did not show definit central nervous system abnormalities. Our findings were as follows: (1) The ventricular enlargement was observed in the parkinsonian patients who showed dementia and/or Yahr's classification grades IV or V. (2) There was no correlation between the duration of this disease and the L--dopa treatments with the ventricular size and sulcal numbers. (3) The side effects of drugs such as visual hallucination were tended to be observed in the patients who showed the ventricular enlargement. (4) There was no definite correlation between the degree of cortical atrophy with clinical symptoms and side effects of various drugs. These findings suggested that the ventricular enlargement in Parkinson's disease was an important sign of dementia and the tendency of appearance of side effects of various drugs. (author)

  8. New scoring system for intra-abdominal injury diagnosis after blunt trauma.

    Science.gov (United States)

    Shojaee, Majid; Faridaalaee, Gholamreza; Yousefifard, Mahmoud; Yaseri, Mehdi; Arhami Dolatabadi, Ali; Sabzghabaei, Anita; Malekirastekenari, Ali

    2014-01-01

    An accurate scoring system for intra-abdominal injury (IAI) based on clinical manifestation and examination may decrease unnecessary CT scans, save time, and reduce healthcare cost. This study is designed to provide a new scoring system for a better diagnosis of IAI after blunt trauma. This prospective observational study was performed from April 2011 to October 2012 on patients aged above 18 years and suspected with blunt abdominal trauma (BAT) admitted to the emergency department (ED) of Imam Hussein Hospital and Shohadaye Hafte Tir Hospital. All patients were assessed and treated based on Advanced Trauma Life Support and ED protocol. Diagnosis was done according to CT scan findings, which was considered as the gold standard. Data were gathered based on patient's history, physical exam, ultrasound and CT scan findings by a general practitioner who was not blind to this study. Chi-square test and logistic regression were done. Factors with significant relationship with CT scan were imported in multivariate regression models, where a coefficient (β) was given based on the contribution of each of them. Scoring system was developed based on the obtained total β of each factor. Altogether 261 patients (80.1% male) were enrolled (48 cases of IAI). A 24-point blunt abdominal trauma scoring system (BATSS) was developed. Patients were divided into three groups including low (scoretool for BAT detection and has the potential to reduce unnecessary CT scan and cut unnecessary costs.

  9. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  10. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  11. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    International Nuclear Information System (INIS)

    Breen, Micheal; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  12. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  13. Computed tomographic evaluation of abdominal fat in minipigs.

    Science.gov (United States)

    Chang, Jinhwa; Jung, Joohyun; Lee, Hyeyeon; Chang, Dongwoo; Yoon, Junghee; Choi, Mincheol

    2011-03-01

    Computed tomography (CT) exams were conducted to determine the distribution of abdominal fat identified based on the CT number measured in Hounsfield Units (HU) and to measure the volume of the abdominal visceral and subcutaneous fat in minipigs. The relationship between the CT-based fat volumes of several vertebral levels and the entire abdomen and anthropometric data including the sagittal abdominal diameter and waist circumference were evaluated. Moreover, the total fat volumes at the T11, T13, L3, and L5 levels were compared with the total fat volume of the entire abdomen to define the landmark of abdominal fat distribution. Using a single-detector CT, six 6-month-old male minipigs were scanned under general anesthesia. Three radiologists then assessed the HU value of visceral and subcutaneous abdominal fat by drawing the region of interest manually at the T11, T13, L1, L3, and L5 levels. The CT number and abdominal fat determined in this way by the three radiologists was found to be correlated (intra-class coefficient = 0.9). The overall HU ranges for the visceral and subcutaneous fat depots were -147.47 to -83.46 and -131.62 to -90.97, respectively. The total fat volume of the entire abdomen was highly correlated with the volume of abdominal fat at the T13 level (r = 0.97, p abdominal adipose tissue measured at the T13 level using CT is a strong and reliable predictor of total abdominal adipose volume.

  14. A fully automatic end-to-end method for content-based image retrieval of CT scans with similar liver lesion annotations.

    Science.gov (United States)

    Spanier, A B; Caplan, N; Sosna, J; Acar, B; Joskowicz, L

    2018-01-01

    The goal of medical content-based image retrieval (M-CBIR) is to assist radiologists in the decision-making process by retrieving medical cases similar to a given image. One of the key interests of radiologists is lesions and their annotations, since the patient treatment depends on the lesion diagnosis. Therefore, a key feature of M-CBIR systems is the retrieval of scans with the most similar lesion annotations. To be of value, M-CBIR systems should be fully automatic to handle large case databases. We present a fully automatic end-to-end method for the retrieval of CT scans with similar liver lesion annotations. The input is a database of abdominal CT scans labeled with liver lesions, a query CT scan, and optionally one radiologist-specified lesion annotation of interest. The output is an ordered list of the database CT scans with the most similar liver lesion annotations. The method starts by automatically segmenting the liver in the scan. It then extracts a histogram-based features vector from the segmented region, learns the features' relative importance, and ranks the database scans according to the relative importance measure. The main advantages of our method are that it fully automates the end-to-end querying process, that it uses simple and efficient techniques that are scalable to large datasets, and that it produces quality retrieval results using an unannotated CT scan. Our experimental results on 9 CT queries on a dataset of 41 volumetric CT scans from the 2014 Image CLEF Liver Annotation Task yield an average retrieval accuracy (Normalized Discounted Cumulative Gain index) of 0.77 and 0.84 without/with annotation, respectively. Fully automatic end-to-end retrieval of similar cases based on image information alone, rather that on disease diagnosis, may help radiologists to better diagnose liver lesions.

  15. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... in direct visual contact and usually with the ability to hear and talk to you with the use of a speaker and microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different body parts absorb the x-rays in varying ...

  17. Relationship between abdominal fat area measured by screening abdominal fat CT and metabolic syndrome in asymptomatic Korean individuals

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dae Woong; Park, Noh Hyuck; Park, Ji Yeon; Kim, Seon Jeong [Dept. of Radiology, MyoungJi Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    The purpose of this study was to investigate the relationship between abdominal fat as assessed by abdominal fat CT and metabolic syndrome (MS), especially in asymptomatic Korean individuals. Retrospectively, a medical record analysis was performed in a total of 111 patients with screening abdominal fat CT. The data such as visceral fat (VF), subcutaneous fat (SF) and VF/SF were elicited by abdominal fat CT, and we analyzed the relationship of VF, SF, and VF/SF with MS and cardiovascular risk factors. In males, VF and SF had a positive correlation with many cardiovascular risk factors and MS, but VF was superior to SF. In females, VF, but not SF, had a positive correlation with some cardiovascular risk factors and MS. The cut-off values of VF and SF to predict MS, which were calculated by drawing receiver operating characteristic curves, were as follows: the cut-off value of VF in men: 136.50 cm{sup 2}, the cut-off value of SF in men: 159.50 cm{sup 2}, and the cut-off value of VF in women: 134.50 cm{sup 2}. In conclusion, VF accumulation was the best predictor of MS and it had a positive correlation with cardiovascular risk factors in both sexes. SF also had a significant association with MS, especially in men, although it was not superior to VF.

  18. Relationship between abdominal fat area measured by screening abdominal fat CT and metabolic syndrome in asymptomatic Korean individuals

    International Nuclear Information System (INIS)

    Park, Dae Woong; Park, Noh Hyuck; Park, Ji Yeon; Kim, Seon Jeong

    2017-01-01

    The purpose of this study was to investigate the relationship between abdominal fat as assessed by abdominal fat CT and metabolic syndrome (MS), especially in asymptomatic Korean individuals. Retrospectively, a medical record analysis was performed in a total of 111 patients with screening abdominal fat CT. The data such as visceral fat (VF), subcutaneous fat (SF) and VF/SF were elicited by abdominal fat CT, and we analyzed the relationship of VF, SF, and VF/SF with MS and cardiovascular risk factors. In males, VF and SF had a positive correlation with many cardiovascular risk factors and MS, but VF was superior to SF. In females, VF, but not SF, had a positive correlation with some cardiovascular risk factors and MS. The cut-off values of VF and SF to predict MS, which were calculated by drawing receiver operating characteristic curves, were as follows: the cut-off value of VF in men: 136.50 cm"2, the cut-off value of SF in men: 159.50 cm"2, and the cut-off value of VF in women: 134.50 cm"2. In conclusion, VF accumulation was the best predictor of MS and it had a positive correlation with cardiovascular risk factors in both sexes. SF also had a significant association with MS, especially in men, although it was not superior to VF

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... such as inflammation of the bronchi (breathing passages) birth defects trauma to blood vessels or lung CT ... used to: diagnose appendicitis detect abdominal tumors or birth defects In the pelvic region, CT scans can ...

  20. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  1. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  2. Selective Nonoperative Management of Penetrating Abdominal Solid Organ Injuries

    Science.gov (United States)

    Demetriades, Demetrios; Hadjizacharia, Pantelis; Constantinou, Costas; Brown, Carlos; Inaba, Kenji; Rhee, Peter; Salim, Ali

    2006-01-01

    Objective: To assess the feasibility and safety of selective nonoperative management in penetrating abdominal solid organ injuries. Background: Nonoperative management of blunt abdominal solid organ injuries has become the standard of care. However, routine surgical exploration remains the standard practice for all penetrating solid organ injuries. The present study examines the role of nonoperative management in selected patients with penetrating injuries to abdominal solid organs. Patients and Methods: Prospective, protocol-driven study, which included all penetrating abdominal solid organ (liver, spleen, kidney) injuries admitted to a level I trauma center, over a 20-month period. Patients with hemodynamic instability, peritonitis, or an unevaluable abdomen underwent an immediate laparotomy. Patients who were hemodynamically stable and had no signs of peritonitis were selected for further CT scan evaluation. In the absence of CT scan findings suggestive of hollow viscus injury, the patients were observed with serial clinical examinations, hemoglobin levels, and white cell counts. Patients with left thoracoabdominal injuries underwent elective laparoscopy to rule out diaphragmatic injury. Outcome parameters included survival, complications, need for delayed laparotomy in observed patients, and length of hospital stay. Results: During the study period, there were 152 patients with 185 penetrating solid organ injuries. Gunshot wounds accounted for 70.4% and stab wounds for 29.6% of injuries. Ninety-one patients (59.9%) met the criteria for immediate operation. The remaining 61 (40.1%) patients were selected for CT scan evaluation. Forty-three patients (28.3% of all patients) with 47 solid organ injuries who had no CT scan findings suspicious of hollow viscus injury were selected for clinical observation and additional laparoscopy in 2. Four patients with a “blush” on CT scan underwent angiographic embolization of the liver. Overall, 41 patients (27

  3. CT scan for the diagnosis of maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Kimura, Yo; Kato, Isao; Aoyagi, Masaru; Kikuchi, Akira; Koike, Yoshio; Suzuki, Hachiro.

    1984-01-01

    A comparative study between the conventional radiological examination and the computed tomographical examination for the diagnosis of maxillary sinus carcinoma was done. CT scan has been more appreciated to detect the tumor invasion in the pterygopalatine fossa, orbit, posterior ethmoid sinus and skull base than the conventional examination. CT scan was most usefull for the determination of size and location of the tumor. The prognosis by the stage-grouping was significantly separated by the new classification with CT scan. Therefore, new TNM classification of maxillary sinus carcinoma with CT scan should be taken into account. (author)

  4. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  5. Automatic spectral imaging protocol selection and iterative reconstruction in abdominal CT with reduced contrast agent dose: initial experience.

    Science.gov (United States)

    Lv, Peijie; Liu, Jie; Chai, Yaru; Yan, Xiaopeng; Gao, Jianbo; Dong, Junqiang

    2017-01-01

    To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. One hundred and sixty patients were randomly divided into two scan protocols (n = 80 each; protocol A, 120 kVp/450 mgI/kg, filtered back projection algorithm (FBP); protocol B, spectral CT imaging with ASIS and 40 to 70 keV monochromatic images generated per 300 mgI/kg, ASIR algorithm. Quantitative parameters (image noise and contrast-to-noise ratios [CNRs]) and qualitative visual parameters (image noise, small structures, organ enhancement, and overall image quality) were compared. Monochromatic images at 50 keV and 60 keV provided similar or lower image noise, but higher contrast and overall image quality as compared with 120-kVp images. Despite the higher image noise, 40-keV images showed similar overall image quality compared to 120-kVp images. Radiation dose did not differ between the two protocols, while contrast agent dose in protocol B was reduced by 33 %. Application of ASIR and ASIS to monochromatic imaging from 40 to 60 keV allowed contrast agent dose reduction with adequate image quality and without increasing radiation dose compared to 120 kVp with FBP. • Automatic spectral imaging protocol selection provides appropriate scan protocols. • Abdominal CT is feasible using spectral imaging and 300 mgI/kg contrast agent. • 50-keV monochromatic images with 50 % ASIR provide optimal image quality.

  6. Radiation dose reduction on multidetector abdominal CT using adaptive statistical iterative reconstruction technique in children

    International Nuclear Information System (INIS)

    Zhang Qifeng; Peng Yun; Duan Xiaomin; Sun Jihang; Yu Tong; Han Zhonglong

    2013-01-01

    Objective: To investigate the feasibility to reduce radiation doses on pediatric multidetector abdominal CT using the adaptive statistical iterative reconstruction technique (ASIR) associated with automated tube current modulation technique (ATCM). Methods: Thirty patients underwent abdominal CT with ATCM and the follow-up scan with ATCM cooperated with 40% ASIR. ATCM was used with age dependent noise index (NI) settings: NI = 9 for 0-5 year old and NI = 11 for > 5 years old for simple ATCM group, NI = 11 for 0-5 year old and NI = 15 for > 5 years old for ATCM cooperated with 40% ASIR group (AISR group). Two radiologists independently evaluated images for diagnostic quality and image noise with subjectively image quality score and image noise score using a 5-point scale. Interobserver agreement was assessed by Kappa test. The volume CT dose indexes (CTDIvol) for the two groups were recorded. Statistical significance for the CTDIvol value was analyzed by pair-sample t test. Results: The average CTDIvol for the ASIR group was (1.38 ± 0.64) mGy, about 60% lower than (3.56 ± 1.23) mGy for the simple ATCM group, and the CTDIvol of two groups had statistically significant differences. (t = 33.483, P < 0.05). The subjective image quality scores for the simple ATCM group were 4.43 ± 0.57 and 4.37 ±0.61, Kappa = 0.878, P < 0.01 (ASIR group: 4.70 ± 0.47 and 4.60 ± 0.50, Kappa = 0.783, P < 0.01), by two observers. The image noise score for the simple ATCM group were 4.03 ±0.56 and 3.83 ±0.53, Kappa = 0.572, P < 0.01 (ASIR group: 4.20 ± 0.48 and 4.10 ± 0.48, Kappa = 0.748, P < 0.01), by two observers. All images had acceptable diagnostic image quality. Conclusion: Lower radiation dose can be achieved by elevating NI with ASIR in pediatric CT abdominal studies, while maintaining diagnostically acceptable images. (authors)

  7. Recent advances of CT in the diagnosis of abdominal malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Y [Tokyo Univ. (Japan). Faculty of Medicine

    1980-08-01

    Advantages and limitations of CT in the diagnosis of abdominal malignancies are discussed in liver, pancreas, adrenal gland and recurrent tumor. As to hepatocellular carcinoma, main tumors were clearly demonstrated in 83%, equivocally in 9% and negatively in 8%. Rapid injection of contrast material was useful in dividing hepatic masses into hyper- and hypovascular tumors. Sensitivity of pancreatic cancer was high enough, but CT was of limited value in detecting a resectable one. CT was highly effective in diagnosis of adrenal tumors and recurrent tumors.

  8. The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Vammen, Sten; Juul, Søren

    1999-01-01

    the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.......the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs....

  9. Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom

    Directory of Open Access Journals (Sweden)

    Martin Beeres

    2015-01-01

    Full Text Available Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany. The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV - at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised.

  10. Immersive Virtual Reality for Visualization of Abdominal CT.

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A; Bodenheimer, Robert E

    2013-03-28

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two-dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  11. Immersive virtual reality for visualization of abdominal CT

    Science.gov (United States)

    Lin, Qiufeng; Xu, Zhoubing; Li, Bo; Baucom, Rebeccah; Poulose, Benjamin; Landman, Bennett A.; Bodenheimer, Robert E.

    2013-03-01

    Immersive virtual environments use a stereoscopic head-mounted display and data glove to create high fidelity virtual experiences in which users can interact with three-dimensional models and perceive relationships at their true scale. This stands in stark contrast to traditional PACS-based infrastructure in which images are viewed as stacks of two dimensional slices, or, at best, disembodied renderings. Although there has substantial innovation in immersive virtual environments for entertainment and consumer media, these technologies have not been widely applied in clinical applications. Here, we consider potential applications of immersive virtual environments for ventral hernia patients with abdominal computed tomography imaging data. Nearly a half million ventral hernias occur in the United States each year, and hernia repair is the most commonly performed general surgery operation worldwide. A significant problem in these conditions is communicating the urgency, degree of severity, and impact of a hernia (and potential repair) on patient quality of life. Hernias are defined by ruptures in the abdominal wall (i.e., the absence of healthy tissues) rather than a growth (e.g., cancer); therefore, understanding a hernia necessitates understanding the entire abdomen. Our environment allows surgeons and patients to view body scans at scale and interact with these virtual models using a data glove. This visualization and interaction allows users to perceive the relationship between physical structures and medical imaging data. The system provides close integration of PACS-based CT data with immersive virtual environments and creates opportunities to study and optimize interfaces for patient communication, operative planning, and medical education.

  12. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  13. Improved image quality and radiation dose reduction in liver dynamic CT scan with the protocol change

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yu Jin; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5-24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120 kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100 kVp, apply SAFIRE strength 0-5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120 kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100 kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100 kVp than 120 kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality

  14. Nontraumatic abdominal emergencies: acute abdominal pain: diagnostic strategies

    International Nuclear Information System (INIS)

    Marincek, B.

    2002-01-01

    Common causes of acute abdominal pain include appendicitis, cholecystitis, bowel obstruction, urinary colic, perforated peptic ulcer, pancreatitis, diverticulitis, and nonspecific, nonsurgical abdominal pain. The topographic classification of acute abdominal pain (pain in one of the four abdominal quadrants, diffuse abdominal pain, flank or epigastric pain) facilitates the choice of the imaging technique. The initial radiological evaluation often consists of plain abdominal radiography, despite significant diagnostic limitations. The traditional indications for plain films - bowel obstruction, pneumoperitoneum, and the search of ureteral calculi - are questioned by helical computed tomography (CT). Although ultrasonography (US) is in many centers the modality of choice for imaging the gallbladder and the pelvis in children and women of reproductive age, CT is considered to be one of the most valued tools for triaging patients with acute abdominal pain. CT is particularly beneficial in patients with marked obesity, unclear US findings, bowel obstruction, and multiple lesions. The introduction of multidetector row CT (MDCT) has further enhanced the utility of CT in imaging patients with acute abdominal pain. (orig.)

  15. Nontraumatic abdominal emergencies: acute abdominal pain: diagnostic strategies

    Energy Technology Data Exchange (ETDEWEB)

    Marincek, B. [Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich (Switzerland)

    2002-09-01

    Common causes of acute abdominal pain include appendicitis, cholecystitis, bowel obstruction, urinary colic, perforated peptic ulcer, pancreatitis, diverticulitis, and nonspecific, nonsurgical abdominal pain. The topographic classification of acute abdominal pain (pain in one of the four abdominal quadrants, diffuse abdominal pain, flank or epigastric pain) facilitates the choice of the imaging technique. The initial radiological evaluation often consists of plain abdominal radiography, despite significant diagnostic limitations. The traditional indications for plain films - bowel obstruction, pneumoperitoneum, and the search of ureteral calculi - are questioned by helical computed tomography (CT). Although ultrasonography (US) is in many centers the modality of choice for imaging the gallbladder and the pelvis in children and women of reproductive age, CT is considered to be one of the most valued tools for triaging patients with acute abdominal pain. CT is particularly beneficial in patients with marked obesity, unclear US findings, bowel obstruction, and multiple lesions. The introduction of multidetector row CT (MDCT) has further enhanced the utility of CT in imaging patients with acute abdominal pain. (orig.)

  16. Cost reduction in abdominal CT by weight-adjusted dose.

    Science.gov (United States)

    Arana, Estanislao; Martí-Bonmatí, Luis; Tobarra, Eva; Sierra, Consuelo

    2009-06-01

    To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT). A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22-67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified (81 kg). Aortic attenuation was significantly superior (p61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p80 kg, there was an over cost of euro 10.7 per patient. An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of euro 1.34 per patient.

  17. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  18. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  19. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  20. The relationship of body mass index and abdominal fat on the radiation dose received during routine computed tomographic imaging of the abdomen and pelvis.

    Science.gov (United States)

    Chan, Victoria O; McDermott, Shaunagh; Buckley, Orla; Allen, Sonya; Casey, Michael; O'Laoide, Risteard; Torreggiani, William C

    2012-11-01

    To determine the relationship of increasing body mass index (BMI) and abdominal fat on the effective dose acquired from computed tomography (CT) abdomen and pelvis scans. Over 6 months, dose-length product and total milliamp-seconds (mAs) from routine CT abdomen and pelvis scans of 100 patients were recorded. The scans were performed on a 64-slice CT scanner by using an automatic exposure control system. Effective dose (mSv) based on dose-length product, BMI, periumbilical fat thickness, and intra-abdominal fat were documented for each patient. BMI, periumbilical fat thickness, and intra-abdominal fat were compared with effective dose. Thirty-nine men and 61 women were included in the study (mean age, 56.3 years). The mean BMI was 26.2 kg/m(2). The mean effective dose was 10.3 mSv. The mean periumbilical fat thickness was 2.4 cm. Sixty-five patients had a small amount of intra-abdominal fat, and 35 had a large amount of intra-abdominal fat. The effective dose increased with increasing BMI (P abdominal fat (P abdominal fat significantly increases the effective dose received from CT abdomen and pelvis scans. Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Outcome of Blunt Abdominal Traumas with Stable Hemodynamic and Positive FAST Findings.

    Science.gov (United States)

    Behboodi, Firooz; Mohtasham-Amiri, Zahra; Masjedi, Navid; Shojaie, Reza; Sadri, Peyman

    2016-01-01

    Focused assessment with sonography for trauma (FAST) is a highly effective first screening tool for initial classification of abdominal trauma patients. The present study was designed to evaluate the outcome of patients with blunt abdominal trauma and positive FAST findings. The present prospective cross-sectional study was done on patients over 7 years old with normal abdominal examination, positive FAST findings, and available abdominopelvic computed tomography (CT) scan findings. The frequency of need for laparotomy as well as its probable risk factors were calculated. 180 patients were enrolled (mean age: 28.0 ± 11.5 years; 76.7% male). FAST findings were confirmed by abdominopelvic CT scan in only 124 (68.9%) cases. Finally, 12 (6.6%) patients needed laparotomy. Mean age of those in need of laparotomy was significantly higher than others (36.75 ± 11.37 versus 27.34 ± 11.37, p = 0.006). Higher grading of spleen (p = 0.001) and hepatic (p = 0.038) ruptures increased the probability of need for laparotomy. 68.9% of the positive FAST findings in patients with blunt abdominal trauma and stable hemodynamics was confirmed by abdominopelvic CT scan and only 6.6% needed laparotomy. Simultaneous presence of free fluid and air in the abdominal area, old age, and higher grading o solid organ injuries were factors that had a significant correlation with need for laparotomy.

  2. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  3. Venous variants and anomalies on routine abdominal multi-detector row CT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent; Tokmak, Naime

    2007-01-01

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation

  4. Venous variants and anomalies on routine abdominal multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Oguzkurt, Levent [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Tokmak, Naime [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)

    2007-02-15

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation.

  5. Estimation of absorbed doses from paediatric cone-beam CT scans: MOSFET measurements and Monte Carlo simulations.

    Science.gov (United States)

    Kim, Sangroh; Yoshizumi, Terry T; Toncheva, Greta; Frush, Donald P; Yin, Fang-Fang

    2010-03-01

    The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of the Varian On-Board Imager((R)) was built in the MC system. To validate the model, the absorbed doses at each organ location for standard-dose and low-dose modes were measured in the physical phantom with MOSFET detectors; effective doses were also calculated. In the results, the MC simulations were comparable to the MOSFET measurements. This voxelised phantom approach could produce a more accurate dose estimation than the stylised phantom method. This model can be easily applied to multi-detector CT dosimetry.

  6. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  7. Abdominal and pelvic lymph node involvement in non-Hodgkin lymphoma: CT manifestations in Chinese patients

    International Nuclear Information System (INIS)

    Wu Ning; Liu Ying; Chen Yu; Lin Dongmei; Shi Mulan

    2004-01-01

    Objective: To study the CT manifestations of abdominal and pelvic lymph nodes in non- Hodgkin lymphoma (NHL) of Chinese patients, and to investigate their correlation with pathology subtypes. Methods: The CT images of 241 patients with enlargement of abdominal and pelvic lymph nodes involved by NHL were reviewed. Of them, 96 patients whose clinical and imaging data fulfilled the requirement for analysis were included. According to the Clinical Schema for the Lymphoid System, patients were divided into 3 subtypes, indolent lymphoma (IL; n=31), aggressive lymphoma (AL; n=61), very aggressive lymphoma (VAL; n=2), and unclassified lymphoma (UCL; n=2), respectively. Abdominal and pelvic CT scans were undertaken in 46 patients, abdominal CT only in 47 cases, and pelvic CT only in 3 cases. CT with iv contrast administration was obtained in 80 patients. Anatomic sites involved were nominated as retroperitoneal (i.e. paraaortic), abdominal (including paracardiac, gastrohepatic, hepatic hilar, and mesenteric etc), retrocrural, diaphragmatic, common iliac, internal iliac, external iliac, and inguinal nodes, respectively. Size, number, discreteness, and density of the nodal lesions were analyzed, and correlated with pathology subtypes. The minimal dimension of the largest node was measured. Results: (1) Size: Most of the nodes were ≤2 cm in size, 60.5% (219/362 sites) in IL and AL, 56.6% (77/136 sites) in IL, and 62.8%(142/226 sites) in AL, respectively. There was no statistical significant difference of the nodal size between IL and AL in each location (χ 2 =0.341, P=0.559). (2) Number: Mesentery had the largest number of node involvement (6.5 vs 5 nodes on an median, IL vs AL), with retroperitoneum placed second (4 vs 4 nodes, IL vs AL. (3) Discreteness: Most of the nodes were discrete with an incidence of 77.1% (279/362 sites, IL and AL), and 74.3% (101/136 sites) in IL, 78.8% (178/226 sites) in AL, respectively. No statistical significant discrepancy was found between

  8. Clinical and CT scan pictures of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Singounas, E.G.; Krassanakis, K.; Karvounis, P.C. (Evangelismos Hospital, Athens (Greece))

    1982-01-01

    The clinical presentations and CT scan pictures of four patients harbouring big cysticercus cysts are described. The value of CT scanning in detecting these cysts is emphasized, and also the fact that these cysts can behave as space-occyping lesions, which must be differentiated from other cystic formations.

  9. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  10. Use of iDXA spine scans to evaluate total and visceral abdominal fat.

    Science.gov (United States)

    Bea, J W; Hsu, C-H; Blew, R M; Irving, A P; Caan, B J; Kwan, M L; Abraham, I; Going, S B

    2018-01-01

    Abdominal fat may be a better predictor than body mass index (BMI) for risk of metabolically-related diseases, such as diabetes, cardiovascular disease, and some cancers. We sought to validate the percent fat reported on dual energy X-ray absorptiometry (DXA) regional spine scans (spine fat fraction, SFF) against abdominal fat obtained from total body scans using the iDXA machine (General Electric, Madison, WI), as previously done on the Prodigy model. Total body scans and regional spine scans were completed on the same day (N = 50). In alignment with the Prodigy-based study, the following regions of interest (ROI) were assessed from total body scans and compared to the SFF from regional spine scans: total abdominal fat at (1) lumbar vertebrae L2-L4 and (2) L2-Iliac Crest (L2-IC); (3) total trunk fat; and (4) visceral fat in the android region. Separate linear regression models were used to predict each total body scan ROI from SFF; models were validated by bootstrapping. The sample was 84% female, a mean age of 38.5 ± 17.4 years, and mean BMI of 23.0 ± 3.8 kg/m 2 . The SFF, adjusted for BMI, predicted L2-L4 and L2-IC total abdominal fat (%; Adj. R 2 : 0.90) and total trunk fat (%; Adj. R 2 : 0.88) well; visceral fat (%) adjusted R 2 was 0.83. Linear regression models adjusted for additional participant characteristics resulted in similar adjusted R 2 values. This replication of the strong correlation between SFF and abdominal fat measures on the iDXA in a new population confirms the previous Prodigy model findings and improves generalizability. © 2017 Wiley Periodicals, Inc.

  11. Role of F-18 FDG PET/CT in the management of infected abdominal aortic aneurysm due to salmonella

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Jin; Lee, Jin Soo; Cheong, Moon Hyun; Byun, Sung Su; Hyun, In Young [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-12-15

    We present a case of infected abdominal aortic aneurysm due to salmonella enteritidis. F-18 FDG PET/CT was performed to diagnosis and during follow-up after antibiotic treatment. Computed tomography (CT) is considered to be the best diagnostic imaging modality in infected aortic lesions. In this case, a combination of CT and FDG PET/CT provided accurate information for the diagnosis of infected abdominal aortic aneurysm. Moreover, FDG PET/CT made an important contribution of monitoring disease activity during antibiotic treatment.

  12. SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Mench, A [Salem Hospital, Salem, OR (United States); Lipnharski, I; Carranza, C; Lamoureux, R; Smajdor, L; Cormack, B; Mohammed, T; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States); Sinclair, L [Oregon Health & Science University, Portland, OR (United States)

    2015-06-15

    Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality

  13. SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

    International Nuclear Information System (INIS)

    Mench, A; Lipnharski, I; Carranza, C; Lamoureux, R; Smajdor, L; Cormack, B; Mohammed, T; Rill, L; Arreola, M; Sinclair, L

    2015-01-01

    Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality

  14. Radiation dose reduction sinogram affirmed iterative reconstruction and automatic tube voltage modulation(CARE kV) in abdominal CT

    International Nuclear Information System (INIS)

    Shin, Hyun Joo; Chung, Yong Eun; Lee, Young Han; Choi, Jin Young; Park, Mi Suk; Kim, Myeong Jin; Kim, Ki Whang

    2013-01-01

    To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p ≥ 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images.

  15. Image Quality Improvement after Implementation of a CT Accreditation Program

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Choi, Byung Gil; Shin, Yu Ri; Hwang, Seong Su; Ku, Young Mi; Lim, Yeon Soo; Lee, Jae Mun

    2010-01-01

    The purpose of this study was to evaluate any improvement in the quality of abdominal CTs after the utilization of the nationally based accreditation program. Approval was obtained from the Institutional Review Board, and informed consent was waived. We retrospectively analyzed 1,011 outside abdominal CTs, from 2003 to 2007. We evaluated images using a fill-up sheet form of the national accreditation program, and subjectively by grading for the overall CT image quality. CT scans were divided into two categories according to time periods; before and after the implementation of the accreditation program. We compared CT scans between two periods according to parameters pertaining to the evaluation of images. We determined whether there was a correlation between the results of a subjective assessment of the image quality and the evaluation scores of the clinical image. The following parameters were significantly different after the implementation of the accreditation program: identifying data, display parameters, scan length, spatial and contrast resolution, window width and level, optimal contrast enhancement, slice thickness, and total score. The remaining parameters were not significantly different between scans obtained from the two different periods: scan parameters, film quality, and artifacts. After performing the CT accreditation program, the quality of the outside abdominal CTs show marked improvement, especially for the parameters related to the scanning protocol

  16. Role of CT in the Diagnosis of Nonspecific Abdominal Pain: A Multicenter Analysis.

    Science.gov (United States)

    Eisenberg, Jonathan D; Reisner, Andrew T; Binder, William D; Zaheer, Atif; Gunn, Martin L; Linnau, Ken F; Miller, Chad M; Tramontano, Angela C; Herring, Maurice S; Dowling, Emily C; Halpern, Elkan F; Donelan, Karen; Gazelle, G Scott; Pandharipande, Pari V

    2017-03-01

    The objective of our study was to determine whether specific patient and physician factors-known before CT-are associated with a diagnosis of nonspecific abdominal pain (NSAP) after CT in the emergency department (ED). We analyzed data originally collected in a prospective multicenter study. In the parent study, we identified ED patients referred to CT for evaluation of abdominal pain. We surveyed their physicians before and after CT to identify changes in leading diagnoses, diagnostic confidence, and admission decisions. In the current study, we conducted a multiple regression analysis to identify whether the following were associated with a post-CT diagnosis of NSAP: patient age; patient sex; physicians' years of experience; physicians' pre-CT diagnostic confidence; and physicians' pre-CT admission decision if CT had not been available. We analyzed patients with and those without a pre-CT diagnosis of NSAP separately. For the sensitivity analysis, we excluded patients with different physicians before and after CT. In total, 544 patients were included: 10% (52/544) with a pre-CT diagnosis of NSAP and 90% (492/544) with a pre-CT diagnosis other than NSAP. The leading diagnoses changed after CT in a large proportion of patients with a pre-CT diagnosis of NSAP (38%, 20/52). In regression analysis, we found that physicians' pre-CT diagnostic confidence was inversely associated with a post-CT diagnosis of NSAP in patients with a pre-CT diagnosis other than NSAP (p = 0.0001). No other associations were significant in both primary and sensitivity analyses. With the exception of physicians' pre-CT diagnostic confidence, the factors evaluated were not associated with a post-CT diagnosis of NSAP.

  17. Hollow organ perforation in blunt abdominal trauma: the role of diagnostic peritoneal lavage.

    Science.gov (United States)

    Wang, Yu-Chun; Hsieh, Chi-Hsun; Fu, Chih-Yuan; Yeh, Chun-Chieh; Wu, Shih-Chi; Chen, Ray-Jade

    2012-05-01

    With recent advances in radiologic diagnostic procedures, the use of diagnostic peritoneal lavage (DPL) has markedly declined. In this study, we reviewed data to reevaluate the role of DPL in the diagnosis of hollow organ perforation in patients with blunt abdominal trauma. Adult patients who had sustained blunt abdominal trauma and who were hemodynamically stable after initial resuscitation underwent an abdominal computed tomographic (CT) scan. Diagnostic peritoneal lavage was performed for patients who were indicated to receive nonoperative management and where hollow organ perforation could not be ruled out. During a 60-month period, 64 patients who had received abdominal CT scanning underwent DPL. Nineteen patients were diagnosed as having a positive DPL based on cell count ratio of 1 or higher. There were 4 patients who sustained small bowel perforation. The sensitivity and specificity of the cell count ratio for a hollow organ perforation in this study were 100% and 75%, respectively. No missed hollow organ perforations were detected. For patients with blunt abdominal trauma and hemoperitoneum who plan to receive nonoperative management, DPL is still a useful tool to exclude hollow organ perforation that is undetected by CT. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Diagnosis of pituitary adenoma by dynamic CT scanning

    International Nuclear Information System (INIS)

    Tanabe, Sumiyoshi; Uede, Teiji; Daibo, Masahiko; Niwa, Jun; Hashi, Kazuo

    1988-01-01

    The advantage of high resolution CT in the diagnosis of pituitary microadenomas has been established, but the diagnosis becomes more difficult when the pituitary microadenoma is less than 5 mm in diameter. We have studied the usefulness of dynamic CT scans particularly for diagnosis of small microadenomas. The dynamic CT scans were performed for 61 normal pituitary glands and 68 pituitary adenomas (36 microadenomas, 32 macroadenomas) with a GECT/T 9800 scanner. Coronal sections of 1.5 mm thickness were taken at the plane just in front of the pituitary stalk of the pituitary gland. Following a bolus intra-venous injection of 40 - 60 ml of contrast media using an automatic injector, ten consecutive CT scans of 2 seconds scan time were obtained, beginning 2 seconds from the start of intravenous injection. The first seven scans were taken with an interval of 2.3 seconds, and the last three scans with an interval of 10 seconds. Then, time-density curves were obtained at the ROI which were set on the anterior pituitary gland, the vascular bed of the pituitary gland, the pituitary stalk and the area of the pituitary adenoma respectively. In a normal pituitary gland, the density increases gradually and makes an S shaped curve, then attains the maximum density value (92.3 CT number) approximately 60 seconds after the administration of contrast media. The pituitary vascular bed is located in midline on the upper surface of the pituitary gland, and shows a symmetrical square, triangular or rhomboid shape. In case of pituitary adenoma, the time-density curve makes a plateau curve and attains the maximum density value (60.1 CT number) approximately 60 seconds after the administration of contrast media. In microadenoma, the pituitary vascular bed is either deformed or compressed, showing an asymmetrical shape. (author)

  19. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas.

    Science.gov (United States)

    Sabzghabaei, Anita; Shojaee, Majid; Safari, Saeed; Hatamabadi, Hamid Reza; Shirvani, Reza

    2016-01-01

    In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT) scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4), 58.5% (95% CI: 51.2-65.5), 56% (95% CI: 48.5-63.3), 79.6% (95% CI: 71.8-85.7), 1.27% (95% CI: 1.30-1.57), and 0.25% (95% CI: 0.18-0.36), respectively. The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  20. Computed tomography use among children presenting to emergency departments with abdominal pain.

    Science.gov (United States)

    Fahimi, Jahan; Herring, Andrew; Harries, Aaron; Gonzales, Ralph; Alter, Harrison

    2012-11-01

    To evaluate trends in and factors associated with computed tomography (CT) use among children presenting to the emergency department (ED) with abdominal pain. This study was a cross-sectional, secondary analysis of the National Hospital Ambulatory Medical Care Survey data from 1998 to 2008. We identified ED patients aged abdominal pain and collected patient demographic and hospital characteristics, and outcomes related to imaging, hospital admission, and diagnosis of appendicitis. Trend analysis was performed over the study period for the outcomes of interest, and a multivariate regression model was used to identify factors associated with CT use. Of all pediatric ED visits, 6.0% were for abdominal pain. We noted a rise in the proportion of these patients with CT use, from 0.9% in 1998 to 15.4% in 2008 (P pediatric patients with abdominal pain. Some groups of children may have a differential likelihood of receiving CT scans.

  1. Cost reduction in abdominal CT by weight-adjusted dose

    International Nuclear Information System (INIS)

    Arana, Estanislao; Marti-Bonmati, Luis; Tobarra, Eva; Sierra, Consuelo

    2009-01-01

    Aim: To analyze the influence of contrast dose adjusted by weight vs. fixed contrast dose in the attenuation and cost of abdominal computed tomography (CT). Materials and methods: A randomised, consecutive, parallel group study was conducted in 151 patients (74 men and 77 women, age range 22-67 years), studied with the same CT helical protocol. A dose at 1.75 ml/kg was administered in 101 patients while 50 patients had a fixed dose of 120 ml of same non-ionic contrast material (320 mg/ml). Mean enhancements were measured at right hepatic lobe, superior abdominal aorta and inferior cava vein. Statistical analysis was weight-stratified ( 81 kg). Results: Aortic attenuation was significantly superior (p 61 kg in dose-adjusted group, presented higher hepatic attenuation, being statistically significant in those >81 kg (p 80 kg, there was an over cost of Euro 10.7 per patient. Conclusions: An injection volume of 1.75 ml/kg offers an optimal diagnostic quality with a global savings of Euro 1.34 per patient.

  2. Automated detection and volumetric segmentation of the spleen in CT scans; Automatische Detektion und volumetrische Segmentierung der Milz in CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Hammon, M.; Dankerl, P.; Janka, R.; Uder, M.; Cavallaro, A. [Universitaetsklinikum Erlangen (Germany). Radiologisches Inst.; Kramer, M.; Seifert, S.; Tsymbal, A.; Costa, M.J. [Siemens AG, Erlangen (Germany). Corporate Technology

    2012-08-15

    To introduce automated detection and volumetric segmentation of the spleen in spiral CT scans with the THESEUS-MEDICO software. The consistency between automated volumetry (aV), estimated volume determination (eV) and manual volume segmentation (mV) was evaluated. Retrospective evaluation of the CAD system based on methods like ''marginal space learning'' and ''boosting algorithms''. 3 consecutive spiral CT scans (thoraco-abdominal; portal-venous contrast agent phase; 1 or 5 mm slice thickness) of 15 consecutive lymphoma patients were included. The eV: 30 cm{sup 3} + 0.58 (width x length x thickness of the spleen) and the mV as the reference standard were determined by an experienced radiologist. The aV could be performed in all CT scans within 15.2 ({+-} 2.4) seconds. The average splenic volume measured by aV was 268.21 {+-} 114.67 cm{sup 3} compared to 281.58 {+-} 130.21 cm{sup 3} in mV and 268.93 {+-} 104.60 cm{sup 3} in eV. The correlation coefficient was 0.99 (coefficient of determination (R{sup 2}) = 0.98) for aV and mV, 0.91 (R{sup 2} = 0.83) for mV and eV and 0.91 (R{sup 2} = 0.82) for aV and eV. There was an almost perfect correlation of the changes in splenic volume measured with the new aV and mV (0.92; R{sup 2} = 0.84), mV and eV (0.95; R{sup 2} = 0.91) and aV and eV (0.83; R{sup 2} = 0.69) between two time points. The automated detection and volumetric segmentation software rapidly provides an accurate measurement of the splenic volume in CT scans. Knowledge about splenic volume and its change between two examinations provides valuable clinical information without effort for the radiologist. (orig.)

  3. Outcome of Blunt Abdominal Traumas with Stable Hemodynamic and Positive FAST Findings

    Directory of Open Access Journals (Sweden)

    Firooz Behboodi

    2016-04-01

    Full Text Available Introduction: Focused assessment with sonography for trauma (FAST is a highly effective first screening tool for initial classification of abdominal trauma patients. The present study was designed to evaluate the outcome of patients with blunt abdominal trauma and positive FAST findings. Methods: The present prospective cross-sectional study was done on patients over 7 years old with normal abdominal examination, positive FAST findings, and available abdominopelvic computed tomography (CT scan findings. The frequency of need for laparotomy as well as its probable risk factors were calculated. Results: 180 patients were enrolled (mean age: 28.0 ± 11.5 years; 76.7% male. FAST findings were confirmed by abdominopelvic CT scan in only 124 (68.9% cases. Finally, 12 (6.6% patients needed laparotomy. Mean age of those in need of laparotomy was significantly higher than others (36.75 ± 11.37 versus 27.34 ± 11.37, p = 0.006. Higher grading of spleen (p = 0.001 and hepatic (p = 0.038 ruptures increased the probability of need for laparotomy. Conclusion: 68.9% of the positive FAST findings in patients with blunt abdominal trauma and stable hemodynamics was confirmed by abdominopelvic CT scan and only 6.6% needed laparotomy. Simultaneous presence of free fluid and air in the abdominal area, old age, and higher grading o solid organ injuries were factors that had a significant correlation with need for laparotomy.

  4. Clinical and CT imaging features of abdominal fat necrosis

    International Nuclear Information System (INIS)

    Zhao Jinkun; Bai Renju

    2013-01-01

    Fat necrosis is a common pathological change at abdominal cross-sectional imaging, and it may cause abdominal pain, mimic pathological change of acute abdomen, or be asymptomatic and accompany other pathophysiologic processes. Fat necrosis is actually the result of steatosis by metabolism or mechanical injury. Common processes that are present in fat necrosis include epiploic appendagitis, infarction of the greater omentum, pancreatitis, and fat necrosis related to trauma or ischemia. As a common fat disease, fat necrosis should be known by clinicians and radiologists. Main content of this text is the clinical symptoms and CT findings of belly fat necrosis and related diseases. (authors)

  5. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  6. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  7. CT appearances of mucosa-associated lymphoid tissue (MALT) lymphoma

    International Nuclear Information System (INIS)

    Kessar, P.; Norton, A.; Rohatiner, A.Z.S.; Lister, T.A.; Reznek, R.H.

    1999-01-01

    Mucosa-associated lymphoid tissue (MALT) lymphoma is a low-grade lymphoma that differs from high-grade non-Hodgkin lymphoma both clinically and histologically. The CT appearances of MALT lymphoma are described. Of 40 patients referred with biopsy-proven MALT lymphoma, only seven had not had gastrectomy or chemotherapy prior to CT examination. The CT scans of these seven cases were analysed for the degree and extent of gastric wall thickening, enlargement of abdominal and extra-abdominal lymph nodes, and presence of extranodal disease. In all patients the stomach was distended with oral contrast medium and scans performed at narrow collimation, after intravenous administration of 20 mg hyoscine butylbromide. In six patients focal thickening of the gastric wall was 1 cm or less. One patient had thickening of over 4 cm. There was no enlargement of abdominal or extra-abdominal lymph nodes or extension to adjacent organs. Thus on CT, at presentation, MALT lymphoma results in minimal gastric wall thickening, unlike high-grade non-Hodgkin lymphoma, which typically causes bulky gastric disease, nodal enlargement and extension into adjacent organs. CT is therefore of limited value in monitoring response to treatment. With disease greater than minimal thickening, transformation to a higher grade should be considered. (orig.)

  8. Clinical study of retrocaval ureter diagnosed by CT scan

    International Nuclear Information System (INIS)

    Kiriyama, Isao; Hata, Ryosuke; Amemiya, Hiroshi

    1987-01-01

    Although retrocaval ureter is relatively uncommon congenital anomaly, surgical intervention is often necessary to alleviate the clinical signs and symptoms of the patients. Vena cavography has been indispensable imaging modality for the definitive diagnosis of this anomaly. Recently, however, CT scan in addition to excretory urography (IVP) and retrograde pyelography(RP) has been utilized in many reported cases in the diagnosis of retrocaval ureter. We have experienced 3 cases of retrocaval ureter consecutively. In this paper we report these 3 cases of retrocaval ureter, in which CT scan enabled us to confirm the definitive diagnosis. We also report another case of pelviureteric stenosis that was taken for retrocaval ureter by CT scan. Causes of the misdiagnosis is discussed. In conclusion CT scan is useful diagnostic modality in the diagnosis of retrocaval ureter and this lesser invasive technique might lessen the need for vena cavography. (author)

  9. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    International Nuclear Information System (INIS)

    Han, Man Seok; Kim, Tae Hyung; Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol; Cho, Jae Hwan

    2012-01-01

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  10. Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Seok; Kim, Tae Hyung [Dept. of Radiological Science, Kangwon National University, Chuncheon (Korea, Republic of); Lee, Seung Youl; Lee, Myeong Goo; Jeon, Min Cheol [Dept. of Radiology, Chungnam National University Hospital, Daejeon (Korea, Republic of); Cho, Jae Hwan [Dept. of Radiological Science, Gyeongsan University College, Daegu (Korea, Republic of)

    2012-03-15

    Nowadays, most of the hospital serves 'one stop service' for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the waiting time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

  11. Incidental apical disease at CT scanning

    International Nuclear Information System (INIS)

    McLoud, T.C.; Satoh, K.; Shepard, J.O.; Moore, E.H.; Kosiuk, J.P.

    1990-01-01

    Apical caps are commonly noted on standard radiographs. This paper determines how often abnormalities in the extreme apex of the lung could be identified on CT scans obtained for other reasons. A total of 158 consecutive CT scans were reviewed prospectively. Excluded were patients with obvious upper lobe pleural or parenchymal disease. Apical abnormalities were identified in 74 (46.8%) of the 158 cases. The prevalence increased with age (19% in the 8-39-year age group and 82% in patients older than 80 years). Opacities were unilateral in 44.5% and bilateral in 55.5%. The most common abnormality was linear opacities (95%)

  12. Volumetric measurement of the maxillary sinus by coronal CT scan

    International Nuclear Information System (INIS)

    Ikeda, Atsuko

    1996-01-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  13. Volumetric measurement of the maxillary sinus by coronal CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Atsuko [Tokyo Medical and Dental Univ. (Japan). School of Medicine

    1996-08-01

    The volume of the maxillary sinus was estimated by coronal CT scan. The purpose of this study was to compare the estimated volume of the normal maxillary sinus with that of the inflamed maxillary sinus. Patients were classified following evaluation by CT scan of the paranasal sinuses into 3 categories. Group A (n=12): Patients suffered from headache, facial pain and epistaxis, but CT scans of their nasal cavity and paranasal sinus were within normal limits without inflammatory change. Group B (n=69): Patients with bilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory changes in both maxillary sinuses. All of the patients in this group underwent sinus surgery after coronal CT scans. Group C (n=14): Patients with unilateral chronic maxillary sinusitis, CT scans of whom showed inflammatory change in unilateral maxillary sinuses. CT scans of these patients were measured by Plannimeter to take the area of each image of the maxillary sinus. Consecutively imaged areas were summated by integral calculus to obtain an estimate of the sinus volume. The mean maxillary sinus volume in the affected sinuses was significantly smaller than those in the contralateral normal sinuses (p<0.05, Wilcoxon-test). The various volumes of the maxillary sinuses and the developmental cause were discussed. Comparison of groups A with B suggested three distinct patterns; the maxillary sinus volume has decreased due to inflammatory changes in the bone. The small sinuses have a tendency to develop chronic inflammatory change. The aeration in the maxillary sinus may be decreased when anatomic variations that may obstruct the ethmoid infundibulum exist. (K.H.)

  14. The abdominal technetium scan (a decade of experience)

    International Nuclear Information System (INIS)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.; Karp, M.P.; Jewett, T.C. Jr.

    1982-01-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans, 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients

  15. [Diagnostic management in paediatric blunt abdominal trauma - a systematic review with metaanalysis].

    Science.gov (United States)

    Schöneberg, C; Tampier, S; Hussmann, B; Lendemans, S; Waydhas, C

    2014-12-01

    The objective of this systematic review was to investigate the diagnostic management in paediatric blunt abdominal injuries. A literature research was performed using following sources: MEDLINE, Embase and Cochrane. Where it was possible a meta-analysis was performed. Furthermore the level of evidence for all publications was assigned. Indicators for intraabdominal injury (IAI) were elevated liver transaminases, abnormal abdominal examinations, low systolic blood pressure, reduced haematocrit and microhematuria. Detecting IAI with focused assessment with sonography for trauma (FAST) had an overall sensitivity of 56.5 %, a specificity of 94.68 %, a positive likelihood ratio of 10.63 and a negative likelihood ratio of 0.46. The accuracy was 84.02 %. Among haemodynamically unstable children the sensitivity and specificity were 100 %. The overall prevalence of IAI and negative CT was 0.19 %. The NPV of abdominal CT for diagnosing IAI was 99.8 %. The laparotomy rate in patients with isolated intraperitoneal fluid (IIF) in one location was 3.48 % and 56.52 % in patients with IIF in more than one location. FAST as an isolated tool in the diagnostics after blunt abdominal injury is very uncertain, because of the modest sensitivity. Discharging children after blunt abdominal trauma with a negative abdominal CT scan seems to be safe. When IIF is detected on CT scan, it depends on the number of locations involved. If IIF is found only in 1 location, IAI is uncommon, while IIF in two or more locations results in a high laparotomy rate. Georg Thieme Verlag KG Stuttgart · New York.

  16. Analysis of local concentration in stomach fold pattern by using abdominal X-ray CT image

    International Nuclear Information System (INIS)

    Watanabe, Shigeto; Hasegawa, Jun-ichi; Mekada, Yoshito; Mori, Kensaku; Nawano, Shigeru

    2004-01-01

    The paper presents a method for analysis of stomach folds pattern in abdominal X-ray CT images. Many stomach cancers have local concentration of folds at cancer lesions. Therefore, in stomach diagnosis, it is very important to evaluate quantitatively such fold concentration. In this paper, a method for calculation of concentration index for line figure on a curved surface is proposed first. Then, using this method a processing procedure for detection of stomach cancer from an abdominal X-ray CT image is developed. In the experiment using practical X-ray CT images, it is shown that by the proposed procedure, higher values of concentration index are obtained at cancer area. (author)

  17. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  18. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Scott, A; Allahverdian, J [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2014-06-15

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT.

  19. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    International Nuclear Information System (INIS)

    Zhou, Y; Scott, A; Allahverdian, J

    2014-01-01

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT

  20. Whole-body MSCT of patients after polytrauma: abdominal injuries

    International Nuclear Information System (INIS)

    Roehrl, B.; Sadick, M.; Diehl, S.; Dueber, C.; Obertacke, U.

    2005-01-01

    Purpose: The goal of this retrospective study was to evaluate the spectrum of abdominal injuries and the reliability of computed tomography-based diagnosis in patients after polytrauma. Material and methods: CT findings and clinical reports for 177 patients after polytrauma were evaluated with regard to abdominal injuries. Clinical patient reports at the time of discharge from the hospital were utilized as the standard of reference. Abdominal injuries resulting from an accident, frequent additional traumas and following therapeutic procedures were recorded. In the case of discrepancies in the reports, the CT scans were viewed retrospectively. Results: In 30 out of 177 patients, 42 abdominal injuries were detected. 69% of the injuries were caused by traffic accidents while 31% resulted from falls. Liver and spleen injuries were the most common. 50% of the cases were treated surgically, and the other half of the cases underwent non-surgical conservative therapy. Massive chest traumas, pelvic injuries, cerebral traumas and injuries to extremities were commonly associated with abdominal injuries. Evaluation of the discrepancies in the clinical reports showed that injury to the pancreas and the small intestine were not successfully detected on CT, thus resulting in a false negative diagnosis. Early stages of organ parenchyma laceration were also initially misdiagnosed on CT. (orig.)

  1. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    Science.gov (United States)

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  2. Hepatosplenic Candidiasis Detected by 18F-FDG-PET/CT

    International Nuclear Information System (INIS)

    Albano, Domenico; Bosio, Giovanni; Bertoli, Mattia; Petrilli, Giulia; Bertagna, Francesco

    2016-01-01

    Hepatosplenic candidiasis is a fungal infection, which mostly affects patients with hematologic malignancies such as leukemia. The pathogenesis of this infection is not clear yet, and the liver is the most commonly affected organ. Diagnosis of hepatosplenic candidiasis can be only established via biopsy, since computed tomography (CT) scan, ultrasonography, and magnetic resonance imaging (MRI) yield non-specific results. The role of fluorine-18 fluorodeoxyglucose positron emission tomography /computed tomography ( 18 F-FDG PET/CT) in diagnosis of hepatosplenic candidiasis remains undetermined, considering a few evidences in the literature. In this case report, we present the case of a 47-year-old patient, affected by acute myeloid leukemia, which was treated with three cycles of chemotherapy, resulting in the development of neutropenia and fever following the last cycle. The 18 F-FDG PET/CT scan showed some foci of intense FDG uptake in the liver and spleen. The subsequent diagnostic investigations (i.e., abdominal CT scan and biopsy) were suggestive of hepatosplenic candidiasis. The patient was started on antifungal treatment with fluconazole. After one month, the clinical conditions were resolved, and the subsequent abdominal CT scan was negative

  3. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  4. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  5. Serial CT scannings in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Fukushima, Masashi; Sawada, Tohru; Kuriyama, Yoshihiro; Kinugawa, Hidekazu; Yamaguchi, Takenori

    1981-01-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemipare sis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis. (author)

  6. A study of the usefulness of CT in diagnosis of diverticulitis of the right colon and acute appendicitis

    International Nuclear Information System (INIS)

    Watanabe, Jota; Watanabe, Hideo; Tohyama, Taiji; Kushihata, Fumiki; Kobayashi, Nobuaki

    2003-01-01

    It is difficult to differentiate between diverticulitis of the right colon and acute appendicitis based on pathological and hematological findings. This study was designed to investigate the usefulness of CT in differentiation between the both diseases and indications of operation. Eight cases of right colon diverticulitis and 39 cases of acute appendicitis undergone abdominal plain CT scan before surgery were enrolled in the study. As for diverticulitis cases, diverticulum was visualized on abdominal CT scan in seven (87.5%) out of the eight cases. Of 39 cases of acute appendicitis, the appendix vermiformis was able to be visualized on abdominal CT scan in 26 (66.7%) cases. Some correlations between CT findings and postoperative pathological diagnosis of appendicitis were observed. A comparison was made on acute appendicitis cases by dividing them into two groups; namely, the non-surgery group comprising of cases pathologically diagnosed as non-inflammatory and catarrhal' and the surgery group comprising of cases diagnosed as 'phlegmonous and gangrenous' after surgery. Statistically significant difference was noted between both groups in two factors, whole-circumferential thickening of the appendiceal wall and fading panniculus adiposus around the appendix. It is concluded that abdominal CT scan is useful for differential diagnosis between right colon diverticulitis and acute appendicitis, and further that CT diagnosis of acute appendicitis well reflects the severity of the disease and contribute to decide indication of operation. (author)

  7. The optimal parameter for radiation dose in pediatric low dose abdominal CT: cross-sectional dimensions versus body weight

    International Nuclear Information System (INIS)

    Jung, Yoon Young; Goo, Hyun Woo

    2008-01-01

    To investigate the best parameter between cross-sectional dimensions and body weight in pediatric low dose abdominal CT. One hundred and thirty six children consecutively underwent weight-based abdominal CT. The subjects consisted of group 1 (79 children, weight range 10.0-19.9 kg) and group 2 (57 children, weight range 20.0-39.9 kg). Abdominal cross-sectional dimensions including circumference, area, anteroposterior diameters and transverse diameters were calculated. Image noise (standard deviation of CT density) was measured by placing a region of interest in the posterior segment of the right hepatic lobe on a CT image at the celiac axis. The measured image noise was correlated with the cross-sectional abdominal dimensions and body weight for subjects in each group. In group 1 subjects,area, circumference, transverse diameter, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order(γ = 0.63, 0.62, 0.61, 0.51, and 0.49; ρ < 0.0001). In group 2 subjects, transverse diameter, circumference, area, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order (γ = 0.83, 0.82, 0.78, 0.71, and 0.71; ρ < 0.0001). Cross-sectional dimensions such as area, circumference, and transverse diameter showed a higher positive correlation with image noise than body weight for pediatric low dose abdominal CT

  8. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial.

    Science.gov (United States)

    Sierink, Joanne C; Treskes, Kaij; Edwards, Michael J R; Beuker, Benn J A; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G W; Luitse, Jan S K; Beenen, Ludo F M; Hollmann, Markus W; Goslings, J Carel

    2016-08-13

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in patients with trauma. We undertook an international, multicentre, randomised controlled trial at four hospitals in the Netherlands and one in Switzerland. Patients aged 18 years or older with trauma with compromised vital parameters, clinical suspicion of life-threatening injuries, or severe injury were randomly assigned (1:1) by ALEA randomisation to immediate total-body CT scanning or to a standard work-up with conventional imaging supplemented with selective CT scanning. Neither doctors nor patients were masked to treatment allocation. The primary endpoint was in-hospital mortality, analysed in the intention-to-treat population and in subgroups of patients with polytrauma and those with traumatic brain injury. The χ(2) test was used to assess differences in mortality. This trial is registered with ClinicalTrials.gov, number NCT01523626. Between April 22, 2011, and Jan 1, 2014, 5475 patients were assessed for eligibility, 1403 of whom were randomly assigned: 702 to immediate total-body CT scanning and 701 to the standard work-up. 541 patients in the immediate total-body CT scanning group and 542 in the standard work-up group were included in the primary analysis. In-hospital mortality did not differ between groups (total-body CT 86 [16%] of 541 vs standard work-up 85 [16%] of 542; p=0.92). In-hospital mortality also did not differ between groups in subgroup analyses in patients with polytrauma (total-body CT 81 [22%] of 362 vs standard work-up 82 [25%] of 331; p=0.46) and traumatic brain injury (68 [38%] of 178 vs 66 [44%] of 151; p=0.31). Three serious adverse events were reported in patients in the total-body CT group (1%), one in the standard work-up group (<1%), and

  9. The Accuracy of Urinalysis in Predicting Intra-Abdominal Injury Following Blunt Traumas

    Directory of Open Access Journals (Sweden)

    Anita Sabzghabaei

    2016-01-01

    Full Text Available Introduction: In cases of blunt abdominal traumas, predicting the possible intra-abdominal injuries is still a challenge for the physicians involved with these patients. Therefore, this study was designed, to evaluate the accuracy of urinalysis in predicting intra-abdominal injuries. Methods: Patients aged 15 to 65 years with blunt abdominal trauma who were admitted to emergency departments were enrolled. Abdominopelvic computed tomography (CT scan with intravenous contrast and urinalysis were requested for all the included patients. Demographic data, trauma mechanism, the results of urinalysis, and the results of abdominopelvic CT scan were gathered. Finally, the correlation between the results of abdominopelvic CT scan, and urinalysis was determined. Urinalysis was considered positive in case of at least one positive value in gross appearance, blood in dipstick, or red blood cell count. Results: 325 patients with blunt abdominal trauma were admitted to the emergency departments (83% male with the mean age of 32.63±17.48 years. Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of urinalysis, were 77.9% (95% CI: 69.6-84.4, 58.5% (95% CI: 51.2-65.5, 56% (95% CI: 48.5-63.3, 79.6% (95% CI: 71.8-85.7, 1.27% (95% CI: 1.30-1.57, and 0.25% (95% CI: 0.18-0.36, respectively. Conclusion: The diagnostic value of urinalysis in prediction of blunt traumatic intra-abdominal injuries is low and it seems that it should be considered as an adjuvant diagnostic tool, in conjunction with other sources such as clinical findings and imaging.

  10. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  11. Ocular volume measured by CT scans

    International Nuclear Information System (INIS)

    Hahn, F.J.; Wei-Kom Chu

    1984-01-01

    Newer CT scans have greatly enhanced oculometric research and made it possible to measure ocular dimensions. With these measurements, ocular volume can be more accurately estimated to understand its relationship with age and sex. One hundred CT orbit scans with presumed normal eyes were used for the data base. The mean values and normal variations of ocular volumes at various ages in both sexes are presented. Rapid growth of the eyeball was noted during the first 24 months of age. It reached its peak between the ages of 18 and 30 years of age, after which there was a reduction. Results may be of help in recognizing eye abnormalities such as microophthalmus and macrophthalmia. (orig.)

  12. Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation

    International Nuclear Information System (INIS)

    Shekhar, Raj; Lei, Peng; Castro-Pareja, Carlos R.; Plishker, William L.; D'Souza, Warren D.

    2007-01-01

    Conventional radiotherapy is planned using free-breathing computed tomography (CT), ignoring the motion and deformation of the anatomy from respiration. New breath-hold-synchronized, gated, and four-dimensional (4D) CT acquisition strategies are enabling radiotherapy planning utilizing a set of CT scans belonging to different phases of the breathing cycle. Such 4D treatment planning relies on the availability of tumor and organ contours in all phases. The current practice of manual segmentation is impractical for 4D CT, because it is time consuming and tedious. A viable solution is registration-based segmentation, through which contours provided by an expert for a particular phase are propagated to all other phases while accounting for phase-to-phase motion and anatomical deformation. Deformable image registration is central to this task, and a free-form deformation-based nonrigid image registration algorithm will be presented. Compared with the original algorithm, this version uses novel, computationally simpler geometric constraints to preserve the topology of the dense control-point grid used to represent free-form deformation and prevent tissue fold-over. Using mean squared difference as an image similarity criterion, the inhale phase is registered to the exhale phase of lung CT scans of five patients and of characteristically low-contrast abdominal CT scans of four patients. In addition, using expert contours for the inhale phase, the corresponding contours were automatically generated for the exhale phase. The accuracy of the segmentation (and hence deformable image registration) was judged by comparing automatically segmented contours with expert contours traced directly in the exhale phase scan using three metrics: volume overlap index, root mean square distance, and Hausdorff distance. The accuracy of the segmentation (in terms of radial distance mismatch) was approximately 2 mm in the thorax and 3 mm in the abdomen, which compares favorably to the

  13. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial

    NARCIS (Netherlands)

    Sierink, Joanne C.; Treskes, Kaij; Edwards, Michael J. R.; Beuker, Benn J. A.; den Hartog, Dennis; Hohmann, Joachim; Dijkgraaf, Marcel G. W.; Luitse, Jan S. K.; Beenen, Ludo F. M.; Hollmann, Markus W.; Goslings, J. Carel; Saltzherr, T. P.; Schep, N. W. L.; Streekstra, G. J.; van Lieshout, E. M. M.; Patka, P.; Klimek, M.; van Vugt, R.; Tromp, T. J. N.; Brink, M.; Harbers, J. S.; El Moumni, M.; Wendt, K. W.; Bingisser, R.; Ummenhofer, W.; Bless, N.

    2016-01-01

    Published work suggests a survival benefit for patients with trauma who undergo total-body CT scanning during the initial trauma assessment; however, level 1 evidence is absent. We aimed to assess the effect of total-body CT scanning compared with the standard work-up on in-hospital mortality in

  14. Dual scan CT image recovery from truncated projections

    Science.gov (United States)

    Sarkar, Shubhabrata; Wahi, Pankaj; Munshi, Prabhat

    2017-12-01

    There are computerized tomography (CT) scanners available commercially for imaging small objects and they are often categorized as mini-CT X-ray machines. One major limitation of these machines is their inability to scan large objects with good image quality because of the truncation of projection data. An algorithm is proposed in this work which enables such machines to scan large objects while maintaining the quality of the recovered image.

  15. Delayed intracerebral hemorrhage as demonstrated by CT scanning

    International Nuclear Information System (INIS)

    Brunetti, J.; Zingesser, L.; Dunn, J.; Rovit, R.L.; Saint Vincent's Hospital and Medical Center, New York

    1979-01-01

    Three patients are presented who developed delayed intracerebral hematomas after head injury. Two patients had essentially negative CT scans on admission and developed intracerebral hematomas within 24 h after injury. They required surgical treatment and had fatal outcomes. The third patient presented with an epidural hematoma on CT scan, developed an intracerebral hematoma 48 h after evacuation of the epidural hematoma, and did well with conservative management. (orig.) [de

  16. Role of CT scan in diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Salem, O.A.; Khasawneh, M.

    2007-01-01

    To evaluate the diagnostic accuracy of the spiral-CT in patients with clinically suspected acute appendicitis. A total of 124 patients referred for CT scan with suspected appendicitis between January 2005 and October 2006 were assessed for the appendiceal size and the presence of signs of appendicitis. The findings were correlated with surgical histopathology. CT scan had a sensitivity of 95 percent and a specifity of 93 percent and an overall accuracy of 92 percent. The use of spiral CT in patients with equivocal clinical presentation suspected of having acute appendicitis can lead to significant improvement in the preoperative diagnosis. (author)

  17. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Liu, Q; Qiu, J; Zhuo, W [Institute of Radiation Medicine Fudan University, Shanghai (China); Majer, M; Knezevic, Z; Miljanic, S [Radiation Chemistry and Dosimetry Laboratory, Ruder Boskovic Institute, Zagreb (Croatia); Hrsak, H [Clinical Hospital Centre Zagreb, Zagreb (Croatia)

    2016-06-15

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the top of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)

  18. CT-scanning in otolaryngology, 2

    International Nuclear Information System (INIS)

    Kusakari, Jun; Endo, Satomi; Hara, Akira

    1982-01-01

    Combined computerized tomography-sialography was performed in 28 patients with parotid tumors. Sialography was performed in the usual fashion. After confirming the presence of the contrast material within the parotid gland by X-ray, 4 to 5 scannings were done at the width of 10 mm below Repid's base line. With this procedure, the parotid gland was clearly demonstrated and the location of the tumor was shown as a shadow defect. Although the nature of the tumor, especially whether it was malignant or benign was difficult to predict, the CT-findings regarding the size and location of the tumor were completely coincident with the operative findings in all the cases. Accurate appraisal of the relation between the tumor and the facial nerve was possible in all but two cases. The preoperative information obtained from CT-scanning is extremely useful in the case of parotid tumor surgery. (author)

  19. An incidentally found inflamed uterine myoma Causing low abdominal pain, using TC-99m-tektrotyd single photon emission computed tomography-CT hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zandieh, Shahin; Schuetz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg [Hanusch-Hospital, Teaching Hospital of Medical University of Vienna, Vienna (Australia)

    2013-10-15

    We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.

  20. Importance of repeated CT scan in Fournier gangrene treatment: clinical case

    International Nuclear Information System (INIS)

    Ignatenco, Sergiu

    2011-01-01

    A patient of 53 years presented fever, swelling and erythema in the perineal region. After computed tomography (CT) was diagnosed Fournier gangrene. After aggressive surgical debridement postoperative evolution was unfavorable. Repeated CT scan trace spread of infection to new areas that led to new surgical debridement on time. Use of CT scan in the postoperative period allows assessment of the effectiveness of surgical debridement and spread of infection. This article presents CT scan images and the most important periods of intraoperative surgical intervention. (authors)

  1. Serial CT scannings in herpes simplex encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, M.; Sawada, T.; Kuriyama, Y.; Kinugawa, H.; Yamaguchi, T. (National Cardivascular Center, Osaka (Japan))

    1981-10-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemiparesis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis.

  2. Multi-site abdominal tuberculosis mimics malignancy on ~(18)F-FDG PET/CT:Report of three cases

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    18 F-fluorodeoxyglucose positron emission/computed tomography( 18 F-FDG PET/CT)imaging,an established procedure for evaluation of malignancy,shows an increased 18 F-FDG uptake in inflammatory conditions.We present three patients with abdominal pain and weight loss.Conventional imaging studies indicated that abdominal neoplasm and 18 F-FDG PET/CT for assessment of malignancy showed multiple lesions with intense 18 FFDG uptake in abdomen of the three cases.However,the three patients were finally diagnosed wit...

  3. Classication Methods for CT-Scanned Carcass Midsections

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    Computed tomography (CT) has successfully been applied in medical environments for decades. In recent years CT has also made its entry to the industrial environments, including the slaughterhouses. In this paper we investigate classication methods for an online CT system, in order to assist...... in the segmentation of the outer fat layer in the mid- section of CT-scanned pig carcasses. Prior information about the carcass composition can potentially be applied for a fully automated solution, in order to optimize the slaughter line. The methods comprise Markov Random Field and contextual Bayesian classication...

  4. Functional imaging in differentiating bronchial masses: an initial experience with a combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan.

    Science.gov (United States)

    Kumar, Arvind; Jindal, Tarun; Dutta, Roman; Kumar, Rakesh

    2009-10-01

    To evaluate the role of combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in differentiating bronchial tumors observed in contrast enhanced computed tomography scan of chest. Prospective observational study. Place of study: All India Institute of Medical Sciences, New Delhi, India. 7 patients with bronchial mass detected in computed tomography scan of the chest were included in this study. All patients underwent (18)F-FDG PET-CT scan, (68)Ga DOTA-TOC PET-CT scan and fiberoptic bronchoscope guided biopsy followed by definitive surgical excision. The results of functional imaging studies were analyzed and the results are correlated with the final histopathology of the tumor. Histopathological examination of 7 bronchial masses revealed carcinoid tumors (2 typical, 1 atypical), inflammatory myofibroblastic tumor (1), mucoepidermoid carcinoma (1), hamartoma (1), and synovial cell sarcoma (1). The typical carcinoids had mild (18)F-FDG uptake and high (68)Ga DOTA-TOC uptake. Atypical carcinoid had moderate uptake of (18)F-FDG and high (68)Ga DOTA-TOC uptake. Inflammatory myofibroblastic tumor showed high uptake of (18)F-FDG and no uptake of (68)Ga DOTA-TOC. Mucoepidermoid carcinoma showed mild (18)F-FDG uptake and no (68)Ga DOTA-TOC uptake. Hamartoma showed no uptake on either scans. Synovial cell sarcoma showed moderate (18)F-FDG uptake and mild focal (68)Ga DOTA-TOC uptake. This initial experience with the combined use of (18)F-FDG and (68)Ga DOTA-TOC PET-CT scan reveals different uptake patterns in various bronchial tumors. Bronchoscopic biopsy will continue to be the gold standard; however, the interesting observations made in this study merits further evaluation of the utility of the combination of (18)F-FDG PET-CT scan and (68)Ga DOTA-TOC PET-CT scan in larger number of patients with bronchial masses.

  5. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  6. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  7. Algorithm-enabled partial-angular-scan configurations for dual-energy CT.

    Science.gov (United States)

    Chen, Buxin; Zhang, Zheng; Xia, Dan; Sidky, Emil Y; Pan, Xiaochuan

    2018-05-01

    We seek to investigate an optimization-based one-step method for image reconstruction that explicitly compensates for nonlinear spectral response (i.e., the beam-hardening effect) in dual-energy CT, to investigate the feasibility of the one-step method for enabling two dual-energy partial-angular-scan configurations, referred to as the short- and half-scan configurations, on standard CT scanners without involving additional hardware, and to investigate the potential of the short- and half-scan configurations in reducing imaging dose and scan time in a single-kVp-switch full-scan configuration in which two full rotations are made for collection of dual-energy data. We use the one-step method to reconstruct images directly from dual-energy data through solving a nonconvex optimization program that specifies the images to be reconstructed in dual-energy CT. Dual-energy full-scan data are generated from numerical phantoms and collected from physical phantoms with the standard single-kVp-switch full-scan configuration, whereas dual-energy short- and half-scan data are extracted from the corresponding full-scan data. Besides visual inspection and profile-plot comparison, the reconstructed images are analyzed also in quantitative studies based upon tasks of linear-attenuation-coefficient and material-concentration estimation and of material differentiation. Following the performance of a computer-simulation study to verify that the one-step method can reconstruct numerically accurately basis and monochromatic images of numerical phantoms, we reconstruct basis and monochromatic images by using the one-step method from real data of physical phantoms collected with the full-, short-, and half-scan configurations. Subjective inspection based upon visualization and profile-plot comparison reveals that monochromatic images, which are used often in practical applications, reconstructed from the full-, short-, and half-scan data are largely visually comparable except for some

  8. Spinal CT scan, 1. Cervical and thoracic spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ. (Japan))

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections.

  9. The neurolytic celiac plexus block using CT guidance through anterior abdominal approach to control the cancer pain

    International Nuclear Information System (INIS)

    Pan Jie; Yang Ning; Liu Wei; Jin Zhengyu; Zhao Yupei; Cai Lixing

    2001-01-01

    Objective: To evaluate the therapeutic effect and safety of neurolytic celiac plexus block (Ncb) using CT guidance through anterior abdominal approach. Methods: The clinical data of 24 patients who were given NCPB because of the suffering of upper abdominal and back pain caused by pancreatic carcinoma and other cancer in advanced stage were retrospectively analyzed. The therapeutic effect was evaluated with complete pain relief and partial pain relief. Results: The effective rate and complete pain relief rate in short period ( 3 months) were 71.4% and 14.3% respectively. No severe complications occurred. Conclusion: NCPB guided by CT through anterior abdominal approach is an effective, safe and simple method to control the upper abdominal and back pain caused by cancer

  10. Torsion of abdominal appendages presenting with acute abdominal pain

    International Nuclear Information System (INIS)

    Al-Jaberi, Tareq M.; Gharabeih, Kamal I.; Yaghan, Rami J.

    2000-01-01

    Diseases of abnormal appendages are rare causes of abdominal pain in all age groups. Nine patients with torsion and infraction of abdominal appendages were retrospectively reviewed. Four patients had torsion and infarction of the appendices epiploicae, four patients had torsion and infarction of the falciform ligament. The patient with falciform ligament disease represents the first reported case of primary torsion and infarction of the falciform ligament, and the patient with the transverse colon epiplocia represents the first reported case of vibration-induced appendix epiplocia torsion and infarction. The patient with the falciform ligament disease presented with a tender upper abdominal mass and the remaining patients were operated upon with the preoperative diagnosis of acute appendicitis. The presence of normal appendix with free serosanguinous fluid in the peritoneal cavity should raise the possibility of a disease and calls for further evaluation of the intra-abdominal organs. If the diagnosis is suspected preoperatively, CT scan and ultrasound may lead to a correct diagnosis and possibly conservative management. Laparoscopy is playing an increasing diagnostic and therapeutic role in such situations. (author)

  11. CT-scanning of ancient Greenlandic Inuit temporal bones

    International Nuclear Information System (INIS)

    Homoe, P.; Videbaek, H.

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.)

  12. CT-scanning of ancient Greenlandic Inuit temporal bones

    Energy Technology Data Exchange (ETDEWEB)

    Homoe, P [Copenhagen Univ. (Denmark). Lab. of Biological Anthropology and Dept. of Otolaryngology, Head and Neck Surgery; Lynnerup, N [Copenhagen Univ., Lab. of Biological Anthropology and Univ. Inst. of Ferensic Medicine, Copenhagen (Denmark); Videbaek, H [Hvidovre Univ. Hospital, Copenhagen (Denmark). Dept. of Radiology

    1992-01-01

    Additional morphological evidence of former infectious middle ear disease (IMED) was found by CT-scanning in 5 of 6 Greenlandic Inuit crania strongly suspected for former IMED due to earlier examination revealing either bilateral hypocellularity or asymmetry of the pneumatized area of the temporal bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones. (13 refs., 10 figs.).

  13. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... abdominal tumors or birth defects In the pelvic region, CT scans can help: detect cysts or tumors ... tests, treatments and procedures may vary by geographic region. Discuss the fees associated with your prescribed procedure ...

  15. Serial CT scans and Menkes' kinky hair disease

    International Nuclear Information System (INIS)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-01-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 μ g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died. (author)

  16. Various complications of abdominal aortic aneurysm : CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub [The Catholic Univ. of Korea, College of Medicine, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5{+-}3cm, n=3) was significantly larger than that of unruptured AAA(4.9{+-}1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9{+-}1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment.

  17. Various complications of abdominal aortic aneurysm : CT findings

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub

    1997-01-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5±3cm, n=3) was significantly larger than that of unruptured AAA(4.9±1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9±1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment

  18. CT scan of pituitary adenomas

    International Nuclear Information System (INIS)

    Sakoda, K.; Mukada, K.; Yonezawa, M.; Matsumura, S.; Yoshimoto, H.; Mori, S.; Uozumi, T.

    1981-01-01

    CT scan is an extremely useful, almost harmless means of diagnosing pituitary adenomas. Growth hormone (GH)-secreting adenomas tend to have higher absorption coefficent in plain CT than the nonfunctioning and prolactin (PRL)-secreting adenomas. The absorption coefficent on contrast-enhanced CT does not identify the specific type of adenoma. Ring-like enhancement was observed in five nonfunctioning and four PRL-secreting adenomas with suprasellar extension, while cystic components were observed in four nonfunctioning and four PRL-secreting adenomas. In three of ten cases of PRL-secreting microadenomas, the site corresponding to the adenoma was not enhanced, whereas the normal pituitary was. A correlation exists between the size of PRL-secreting adenoma and the serum PRL level, but not between the size of GH-secreting adenomas and the serum GH level. (orig.)

  19. Computed tomography has an important role in hollow viscus and mesenteric injuries after blunt abdominal trauma.

    Science.gov (United States)

    Tan, Ker-Kan; Liu, Jody Zhiyang; Go, Tsung-Shyen; Vijayan, Appasamy; Chiu, Ming-Terk

    2010-05-01

    Computed tomographic (CT) scans have become invaluable in the management of patients with blunt abdominal trauma. No clear consensus exists on its role in hollow viscus injuries (HVI) and mesenteric injuries (MI). The aim of this study was to correlate operative findings of HVI and MI to findings on pre-operative CT. All patients treated for blunt abdominal trauma at Tan Tock Seng Hospital from January 2003 to January 2008 were reviewed. CT scans were only performed if the patients were haemodynamically stable and indicated. All scans were performed with intravenous contrast using a 4-slice CT scanner from 2003 to December 2004 and a 64-slice CT scanner from January 2005 onwards. All cases with documented HVI/MI that underwent both CT scans and exploratory laparotomy were analysed. Thirty-one patients formed the study group, with median age of 40 (range, 22-65) years and a significant male (83.9%) predominance. Vehicular-related incidents accounted for 67.7% of the injuries and the median Injury Severity Score (ISS) was 13 (4-50). The 2 commonest findings on CT scans were extra-luminal gas (35.5%) and free fluid without significant solid organ injuries (93.5%). During exploratory laparotomy, perforation of hollow viscus (51.6%) occurred more frequently than suspected from the initial CT findings of extra-luminal gas. Other notable findings included haemoperitoneum (64.5%), and mesenteric tears (67.7%). None of our patients with HVI and MI had a normal pre-operative CT scan. Our study suggests that patients with surgically confirmed HVI and MI found at laparotomy were very likely to have an abnormal pre-operative CT scan. Unexplained free fluid was a very common finding in blunt HVI/MI and is one major indication to consider exploratory laparotomy. (c) 2009 Elsevier Ltd. All rights reserved.

  20. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  1. Adult head CT scans: the uncertainties of effective dose estimates

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2008-01-01

    Full Text: CT scanning is a high dose imaging modality. Effective dose estimates from CT scans can provide important information to patients and medical professionals. For example, medical practitioners can use the dose to estimate the risk to the patient, and judge whether this risk is outweighed by the benefits of the CT examination, while radiographers can gauge the effect of different scanning protocols on the patient effective dose, and take this into consideration when establishing routine scan settings. Dose estimates also form an important part of epidemiological studies examining the health effects of medical radiation exposures on the wider population. Medical physicists have been devoting significant effort towards estimating patient radiation doses from diagnostic CT scans for some years. The question arises: How accurate are these effective dose estimates? The need for a greater understanding and improvement of the uncertainties in CT dose estimates is now gaining recognition as an important issue (BEIR VII 2006). This study is an attempt to analyse and quantify the uncertainty components relating to effective dose estimates from adult head CT examinations that are calculated with four commonly used methods. The dose estimation methods analysed are the Nagel method, the ImpaCT method, the Wellhoefer method and the Dose-Length Product (DLP) method. The analysis of the uncertainties was performed in accordance with the International Standards Organisation's Guide to the Expression of Uncertainty in Measurement as discussed in Gregory et al (Australas. Phys. Eng. Sci. Med., 28: 131-139, 2005). The uncertainty components vary, depending on the method used to derive the effective dose estimate. Uncertainty components in this study include the statistical and other errors from Monte Carlo simulations, uncertainties in the CT settings and positions of patients in the CT gantry, calibration errors from pencil ionization chambers, the variations in the organ

  2. Radiation dose reduction in pediatric CT

    International Nuclear Information System (INIS)

    Robinson, A.E.; Hill, E.P.; Harpen, M.D.

    1986-01-01

    The relationship between image noise and radiation dose was investigated in computed tomography (CT) images of a pediatric abdomen phantom. A protocol which provided a minimum absorbed dose consistent with acceptable image noise criteria was determined for a fourth generation CT scanner. It was found that pediatric abdominal CT scans could maintain diagnostic quality with at least a 50% reduction in dose from the manufacturers' suggested protocol. (orig.)

  3. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  4. Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential

    Energy Technology Data Exchange (ETDEWEB)

    Gnannt, Ralph; Winklehner, Anna; Frauenfelder, Thomas; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Eberli, Daniel [University Hospital Zurich, Clinic for Urology, Zurich (Switzerland); Knuth, Alexander [University Hospital Zurich, Clinic for Oncology, Zurich (Switzerland)

    2012-09-15

    To evaluate prospectively, in patients with testicular cancer, the radiation dose-saving potential and image quality of contrast-enhanced chest and abdominal CT with automated tube potential selection. Forty consecutive patients with testicular cancer underwent contrast-enhanced arterio-venous chest and portal-venous abdominal CT with automated tube potential selection (protocol B; tube potential 80-140 kVp), which is based on the attenuation of the CT topogram. All had a first CT at 120 kVp (protocol A) using the same 64-section CT machine and similar settings. Image quality was assessed; dose information (CTDI{sub vol}) was noted. Image noise and attenuation in the liver and spleen were significantly higher for protocol B (P < 0.05 each), whereas attenuation in the deltoid and erector spinae muscles was similar. In protocol B, tube potential was reduced to 100 kVp in 18 chest and 33 abdominal examinations, and to 80 kVp in 5 abdominal CT examinations; it increased to 140 kVp in one patient. Image quality of examinations using both CT protocols was rated as diagnostic. CTDI{sub vol} was significantly lower for protocol B compared to protocol A (reduction by 12%, P < 0.01). In patients with testicular cancer, radiation dose of chest and abdominal CT can be reduced with automated tube potential selection, while image quality is preserved. (orig.)

  5. CT in the evaluation of severe liver trauma

    International Nuclear Information System (INIS)

    Machado, Marcel Autran C.; Souza Rocha, Manoel de; Machado, Manoel C.C.; Macedo Neto, Augusto Cesar de; Maciel, Rosangela Pereira; Simonetti, Celso.

    1995-01-01

    Abdominal CT is a common examination in the evaluation of patients with blunt abdominal trauma and clinical suspicion for solid organ injury when reasons for immediate laparotomy are not present. A case of major blunt hepatic injury in a 22-year-old patient is reported. The authors present a brief review of the literature and discussion about the role of CT scan in the evaluation of hepatic trauma, surgical planning and postoperative follow-up. (author). 15 refs., 3 figs., 1 tab

  6. Automated image quality assessment for chest CT scans.

    Science.gov (United States)

    Reeves, Anthony P; Xie, Yiting; Liu, Shuang

    2018-02-01

    Medical image quality needs to be maintained at standards sufficient for effective clinical reading. Automated computer analytic methods may be applied to medical images for quality assessment. For chest CT scans in a lung cancer screening context, an automated quality assessment method is presented that characterizes image noise and image intensity calibration. This is achieved by image measurements in three automatically segmented homogeneous regions of the scan: external air, trachea lumen air, and descending aorta blood. Profiles of CT scanner behavior are also computed. The method has been evaluated on both phantom and real low-dose chest CT scans and results show that repeatable noise and calibration measures may be realized by automated computer algorithms. Noise and calibration profiles show relevant differences between different scanners and protocols. Automated image quality assessment may be useful for quality control for lung cancer screening and may enable performance improvements to automated computer analysis methods. © 2017 American Association of Physicists in Medicine.

  7. Topographic diagnosis of parathyroid tumor by CT scan

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Harioka, Toshio; Morita, Rikuji

    1981-01-01

    In order to detect the hyperfunctioning parathyroid gland(s), CT scan over the neck was performed in patients with parathyroid disorders, including 10 primary hyperparathyroidism (6 bone type, 3 stone type and 1 chemical type), 8 chronic renal failure on hemodialysis with renal osteodystrophy and 2 multiple endocrine adenomatosis (MEA) type I. We used a whole-body scanner (CT/T, GE). The slice thickness was 5 mm. All patients were scanned from the sternal notch upward to the larynx, and were enhanced by the administration of 30% DIP Conray for 15 min. The results of the topographic diagnosis were compared with the surgical findings. Precise preoperative localization was accomplished in 9/10 adenomas in primary hyperparathyroidism, 27/32 hyperplasias in secondary hyperparathyroidism, and 2/4 hyperplasias in MEA type I. The smallest lesion weighed 0.2 g. It was shown that CT scan over the neck was a noninvasive and simple method to define the localization of hyperfunctionig parathyroid gland(s). (author)

  8. Dual purpose QA tool developed for teletherapy unit and CT scan in SNDH

    International Nuclear Information System (INIS)

    Shilvant, D.V.; Tamane, C.J.; Pangam, S.B.; Raees, M.D.; Aynoor, S.K.; Pol, P.S.; Verghese, Aju; Ghorpade, C.J.

    2007-01-01

    To make a simple device used in Teletherapy unit and CT scan for depth data measurement. The accurate depth data is essential and very important factor for precise treatment in SAD isocentric setup calculation. In CT scan based treatment planning, the calculation obtained is from the depth given by the CT scan. The success of treatment depends on the same parameters in treatment unit matched with diagnostic CT scan data. To check the depth parameters in both CT scan and Teletherapy unit we have developed a single QA tool in our hospital. As this tool is precise, handy and easily accessible the results obtained from it assures the quality of Teletherapy unit as well as CT scan depth data. This small device resulted data helps a lot in calculations of complicated SAD setup in Telecobalt and also useful in recent new treatment modalities such as IMRT, micro MLC, etc

  9. Computed tomographic diagnosis of abdominal abscess in childhood

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Berger, P.E.

    1980-01-01

    Twenty-eight children suspected clinically of having an abdominal abscess were examined by CT. Eighteen had gallium 67 citrate scans and 22 had ultrasound studies. Computed tomography was found to be the most accurate test for diagnosis and evaluation of an abscess and the computed tomographic appearance of abscess is illustrated. However, because of cost factors, radiation dose, and clinical considerations, computed tomography is not always the first modality of choice in evaluating a suspected abdominal abscess [fr

  10. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  11. Impact of the planning CT scan time on the reflection of the lung tumor motion

    International Nuclear Information System (INIS)

    Kim, Su San; Choi, Eun Kyung; Yi, Byong Yong; Ha, Sung Whan

    2004-01-01

    To evaluate the reflection of tumor motion according to the planning CT scan time. A model of N-shape, which moved along the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T; CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.33 T, and 1.53 T. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery in the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (IQ Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Light Speed, GE Medical System, with a scan time of 0.8 second per slice) were performed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 T, but remained constant above 1.00 T. Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be 100%, CT scans with scan times of 0.33, 0.50, 0.67, and 0.75 T missed the tumor motion by 30, 27, 20, and 7.0% respectively. Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis increased by 6.3, 17, and 23% in the slow CT scans. As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also

  12. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  13. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  14. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  15. CT scans in encephalitis

    International Nuclear Information System (INIS)

    Imanishi, Masami; Morimoto, Tetsuya; Iida, Noriyuki; Hisanaga, Manabu; Kinugawa, Kazuhiko

    1980-01-01

    Generally, CT scans reveal a decrease in the volume of the ventricular system, sylvian fissures and cortical sulci in the acute stage of encephalitis, and softening of the cerebral lobes with dilatation of the lateral ventricles and subarachnoidian dilated spaces in the chronic stage. We encountered three cases of encephalitis: mumps (case 1), herpes simplex (case 2), and syphilis (case 3). In case 1, brain edema was seen in the acute stage and brain atrophy in the chronic stage. In case 2, necrosis of the temporal pole, which is pathognomonic in herpes simplex encephalitis, was recognized. And in case 3, multiple lesions whose CT appearance was enhanced by contrast materials were found scattered over the whole brain. These lesions were diagnosed as inflammatory granuloma by histological examination. (author)

  16. Role of multidetector abdominal CT in the evaluation of abnormalities in polyarteritis nodosa

    International Nuclear Information System (INIS)

    Singhal, M.; Gupta, P.; Sharma, A.; Lal, A.; Rathi, M.; Khandelwal, N.

    2016-01-01

    Aim: To identify arterial and end-organ abnormalities on abdominal computed tomography (CT) in patients with polyarteritis nodosa (PAN). Materials and methods: A prospective study comprising 27 consecutive patients with PAN was conducted from 2007 to 2013. Departmental ethics committee approval was obtained. All patients underwent contrast-enhanced CT comprising an arterial and a portal venous phase. Images were assessed for arterial irregularity, aneurysms, stenosis, and occlusion. End-organ changes, including infarcts, haematoma, and bowel involvement, were also recorded. Results: A positive CT was recorded in 15 patients including eight females. The mean age was 32 years. The most common abnormalities were aneurysms seen in 12 patients. The renal artery was the most common site of aneurysms (n=9). The hepatic (n=3), superior mesenteric (n=3) and splenic arteries (n=1) were also involved. Contour irregularity was noted in four patients involving the hepatic, splenic, and superior mesenteric arteries. Stenosis/occlusion was also noted in seven patients. The most common end-organ abnormality was infarct (n=9), followed by bowel wall thickening (n=3), and perinephric haematoma (n=2). Conclusion: A combination of arterial and end-organ abnormalities on abdominal CT enables an accurate diagnosis of PAN in occult cases and may obviate the need for angiography and, sometimes, biopsy. - Highlights: • A combination of findings on CT allows a diagnosis of PAN. • Specific findings include arterial and end organ abnormalities. • The most common abnormalities on CTA and CT are aneurysms and infarcts.

  17. Relationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2014-06-01

    Full Text Available Background and aims. Cone-beam computed tomography (CBCT is an imaging system which has many advantages over computed tomography (CT. In CT scan, Hounsfield Unit (HU is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value. The aim of the present study was to investigate the relationship between gray scale in CBCT and Hounsfield Unit (HU in CT scan. Materials and methods. In this descriptive study, the head of a sheep was scanned with 3 CBCT and one medical CT scanner. Gray scales and HUs were detected on images. Reconstructed data were analyzed to investigate relationship between CBCT gray scales and HUs. Results. A strong correlation between gray scales of CBCT and HUs of CT scan was determined. Conclusion. Considering the fact that gray scale in CBCT is the criteria in measurement of bone density before implant treatments, it is recommended because of the lower dose and cost compared to CT scan.

  18. Predicting need for additional CT scan in children with a non-diagnostic ultrasound for appendicitis in the emergency department.

    Science.gov (United States)

    Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki

    2018-01-01

    This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  20. Effect of reducing abdominal compression during prone CT colonography on ascending colonic rotation during supine-to-prone positional change

    International Nuclear Information System (INIS)

    Jang, Jong eon; Park, Seong Ho; Lee, Jong Seok; Kim, Hyun Jin; KIm, Ah Young; Ha, Hyun Kwon

    2016-01-01

    To determine the effect of reduced abdominal compression in prone position on ascending colonic movement during supine-to-prone positional change during CT colonography (CTC). Eighteen consecutive patients who had undergone prone CTC scanning with cushion blocks placed under the chest and hip/thigh to reduce abdominal compression and had confirmed sessile polyps ≥ 6 mm in the well-distended, straight, mid-ascending colon, were included. Radial location along the ascending colonic luminal circumference (°) was measured for 24 polyps and 54 colonic teniae on supine and prone CTC images. The supine-to-prone change ranging between -180° and +180° (- and + for internal and external colonic rotations, respectively), was determined. In addition, possible causes of any ascending colonic rotations were explored. Abdominal compression during prone CTC scanning completely disappeared with the use of cushion blocks in 17 of 18 patients. However, some degrees of ascending colonic rotation were still observed, with the radial location changes of -22° to 61° (median, 13.9°) for the polyps and similar degrees for teniae. Fifty-four percent and 56% of polyps and teniae, respectively, showed changes > 10°. The radial location change of the polyps was significantly associated with the degree of anterior shift of the small bowel and mesentery (r = 0.722, p < 0.001) and the degree of posterior displacement of the ascending colon (r = 0.566, p = 0.004) during supine-to-prone positional change. Ascending colonic rotation upon supine-to-prone positional change during CTC, mostly in the form of external rotation, is not eliminated by removing abdominal compression in prone position

  1. Evaluation of lateral margin of left lobe of the liver on CT scan : focus on perisplenic extension

    International Nuclear Information System (INIS)

    Seo, Chang Hye; Cha, Seong Sook; Lee, Byung Jin; Choi, Jae Young; Choi, Seok Jin; Eun, Choong Ki

    1996-01-01

    The perisplenic extension of the left lobe of the liver can be misinterpreted as a splenic or perisplenic lesion on ultrasonography(US) and computed tomography(CT). The purpose of our study is to classify the lateral margin of the left lobe of the liver into three types and to evaluate the incidence and the relationship between each type and abnormal liver on CT scan. A total of 515 abdominal CT scans from patients over 15 years old were retrospectively evaluated. Liver contours were divided into three types on the basis of degree of the left lateral extension of the left lobe of the liver. Type A was defined as the lateral extension of the left lobe of liver to the medial portion of the stomach, type C as the perisplenic portion, and type B as between the two types. Each type was further divided into normal and abnormal liver groups based on clinical, CT, surgical and patholigic findings and evaluated on its ratio of normal and abnormal liver, intrahepatic diseases associated with an abnormal liver and statistical significance between a normal and abnormal liver. The incidence of the three types of liver among the 515 patients was 360(69.9%), 121(23.5%) and 34(6.6%) patients in type A, B and C, respectively. Type C showed normal liver in six patients, which was 2.7% of all normal livers(221/515) and abnormal liver in 28 patients, which was 9.5% of all abnormal livers(294/515). Type A showed normal liver in 49.7%, abnormal liver in 50.3% and there was not statistically significant difference between normal and abnormal liver(p>0.05). Type B showed normal liver in 29.8% and abnormal liver in 70.2%;type C showed normal liver in 17.6%, abnormal liver in 82.4% and there was a statistically significant difference between normal and abnormal liver(P<0.001). The space occupying lesion(SOL) was most common(52.6%) in all the abnormal livers and hepatoma was the most common disease in the SOL(47.2%). In the abnormal type C liver, SOL(58%) and diffuse hepatopathy(32.8%) were

  2. Measurements of Epidural Space Depth Using Preexisting CT Scans Correlate with Loss of Resistance Depth during Thoracic Epidural Catheter Placement

    Directory of Open Access Journals (Sweden)

    Nathaniel H. Greene

    2015-01-01

    Full Text Available Background. Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist. Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter. Methods. This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD on computed tomography (CT to determine loss of resistance depth acquired during epidural placement. Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging. Results. There was a strong association between CT measurement and loss of resistance depth (P35 changed this relationship (P=0.007. The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs>0.9. Conclusions. Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter. Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

  3. Colonic polyp detection method from 3D abdominal CT images based on local intensity analysis

    International Nuclear Information System (INIS)

    Oda, M.; Nakada, Y.; Kitasaka, T.; Mori, K.; Suenaga, Y.; Takayama, T.; Takabatake, H.; Mori, M.; Natori, H.; Nawano, S.

    2007-01-01

    This paper presents a detection method of colonic polyps from 3D abdominal CT images based on local intensity analysis. Recently, virtual colonoscopy (VC) has widely received attention as a new colon diagnostic method. VC is considered as a less-invasive inspection method which reduces patient load. However, since the colon has many haustra and its shape is long and convoluted, a physician has to change the viewpoint and the viewing direction of the virtual camera of VC many times while diagnosis. Additionally, there is a risk to overlook lesions existing in blinded areas caused by haustra. This paper proposes an automated colonic polyp detection method from 3D abdominal CT images. Colonic polyps are located on the colonic wall. Their CT values are higher than those of colonic lumen regions and lower than those of fecal materials tagged by an X-ray opaque contrast agent. CT values inside polyps which exist outside the tagged fecal materials tend to gradually increase from outward to inward (blob-like structure). CT values inside polyps that exist inside the tagged fecal materials tend to gradually decrease from outward to inward (inv-blob-like structure). We employ the blob and the inv-blob structure enhancement filters based on the eigenvalues of the Hessian matrix to detect polyps using intensity characteristic of polyps. Connected components with low output values of the enhancement filter are eliminated in false positive reduction process. Small connected components are also eliminated. We applied the proposed method to 44 cases of abdominal CT images. Sensitivity for polyps of 6 mm or larger was 80% with 4.7 false positives per case. (orig.)

  4. Tc-99m sulfur colloid scanning in blunt trauma: detection of abdominal bleeding

    International Nuclear Information System (INIS)

    Bronfman, H.J.; Kunkel, B.K.; Rabin, H.S.

    1981-01-01

    Tc-99m sulfur colloid scintigraphy can detect and locate active lower gastrointestinal bleeding. The same principles apply to the detection and location of active intra-abdominal or pelvic hemorrhage following blunt abdominal trauma. We report two patients with abdominal bleeding who were correctly diagnosed by this method. As part of the routine examination of all patients having Tc-99m sulfur colloid liver-spleen scans for trauma, 500,000-count images should be made of the rest of the abdomen and pelvis

  5. The Beatles, the Nobel Prize, and CT scanning of the chest.

    Science.gov (United States)

    Goodman, Lawrence R

    2010-01-01

    From its first test scan on a mouse, in 1967, to current medical practice, the CT scanner has become a core imaging tool in thoracic diagnosis. Initially financed by money from Beatles' record sales, the first patient scan was performed in 1971. Only 8 years later, a Nobel Prize in Physics and Medicine was awarded to Hounsfield and Cormack for their discovery. This article traces the history of CT scanner development and how each technical advance expanded chest diagnostic frontiers. Chest imaging now accounts for 30% of all CT scanning.

  6. Metastasectomy of Abdominal Wall Lesions due to Prostate Cancer Detected Through PET/CT Gallium 68-PMSA: First Case Report.

    Science.gov (United States)

    Ochoa, Claudia; Ramirez, Angie; Varela, Rodolfo; Godoy, Fabian; Vargas, Rafael; Forero, Jorge; Rojas, Andres; Roa, Carmen; Céspedes, Carlos; Ramos, Jose; Cabrera, Marino; Calderon, Andres

    2017-05-01

    Introducing the topic of abdominal wall metastasis secondary to prostate cancer with a reminder of the disease's rarity, being the first published case. This article is about a 66 year old patient diagnosed with prostate cancer [cT2aNxMx iPSA: 5,6 ng/ml Gleason 3+3, (Grade 1 Group)], treated with radical prostatectomy as well as accompanied with amplified pelvic lymphadenectomy, who subsequently presented metastatic lesions to the abdominal wall diagnosed with PET/CT Gallium 68-PMSA technique and treated with abdominal metastasectomy with adequate short term results.

  7. Acquiring 4D thoracic CT scans using a multislice helical method

    International Nuclear Information System (INIS)

    Keall, P J; Starkschall, G; Shukla, H; Forster, K M; Ortiz, V; Stevens, C W; Vedam, S S; George, R; Guerrero, T; Mohan, R

    2004-01-01

    Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm 3 ). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies

  8. Intraoperative iodinated contrast swallow with CT-scan delayed control for detection of early complications in laparoscopic gastric bypass: A case series of 260 cases

    Directory of Open Access Journals (Sweden)

    Vincenzo Consalvo, M.D.

    2017-01-01

    Conclusions: This study gives a contribute to the existing issue of fast track in bariatric surgery for the early diagnosis of complications and patients' readmission or non-discharge. In conclusion, the use of intraoperative iodinated water soluble contrast swallow and abdominal CT-scan at 48 h was a safe and accurate test in order to detect and treat any potential early surgical complication in LRYGB.

  9. The use of CT scan in the pre-operative staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Pada, C.C.

    1992-01-01

    Surgery remains the treatment of choice in patients with localized bronchogenic carcinoma. Pre-operative identification of inoperability spares the patient from unnecessary surgery. This prospective study was carried out to determine the correctness of judgement regarding a patient's operability or inoperability based on the pre-operative staging of CT scan; to find out the sensitivity, specificity and overall accuracy of the CT scan in estimating tumor description, nodal status and metastatic spread to the chest. Staging was done by 3 senior radiologists aware of the diagnosis. Both the surgical and histopathologic findings and staging were gathered and used as measurement of truth in arriving at the CT scan's accuracy. Overall accuracy rate of CT scan in determining operability or inoperability is 80%; tumor description accuracy of assessment is 87% and nodal status estimation has an accuracy of 60%. Sensitivity of CT scan is assessment of metastatic spread to the chest is 93%. There is no statistically significant difference in the judgement of operability or interpretability by CT scan compared to surgical and histopathologic results. The CT scan is recommended as a valuable tool in the pre-operative staging of patients with bronchogenic carcinoma who are candidates for surgery. (auth.). 21 refs.; 8 tabs

  10. Full-Body CT Scans - What You Need to Know

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Full-Body CT Scans - What You Need to Know Share ... if you are thinking of having a whole-body screening: Whole-body CT screening has not been ...

  11. Effect of staff training on radiation dose in pediatric CT.

    Science.gov (United States)

    Hojreh, Azadeh; Weber, Michael; Homolka, Peter

    2015-08-01

    To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Evolution of traumatic intracerebral hematoma. Analysis of sequential CT scans since per-acute stage

    Energy Technology Data Exchange (ETDEWEB)

    Nagaseki, Yoshishige; Horikoshi, Satoru [Gunma Univ., Maebashi (Japan). School of Medicine; Tamura, Masaru

    1984-05-01

    To clarify the evolution of traumatic intracerebral hematoma (TICH), initial computerized tomography (CT) scans of 28 TICH cases performed within one hour after head trauma were studied along with their follow-up CT scans. They were classified into the following two groups; per-acute group included seven cases in which TICH was completed on the initial CT scans taken within one hour after head injury and acute group included 21 cases in which the initial CT scans revealed isodensity or high density spot and repeat CT scans disclosed TICH by 48 hours after injury. In the per-acute group, initial CT scans showed a homogeneous, well defined, and high density mass (1.5-6.5 cm in diameter). In sequential CT scans of the three cases, the hematoma did not increase but spontaneously disappeared. Other four cases died early after head trauma. Their initial CT scans revealed a large high density mass (3-6.5 cm in diameter) combined with other extracerebral hemorrhages. In the acute group, initial CT scans demonstrated isodensity or high density spot and sequential CT scans showed mottled appearance of salt and pepper appearance, and after a while showed fusion of small high density areas to become a massive high density area (contusional hematoma) by 48 hours after injury. In six cases of this group, the contusional hematoma was removed within 24 hours after injury and in one case at 3.5 days. In other 14 cases, the hematomas shrank or disappeared spontaneously. From these results, it was considered that evolution of TICH's were classified into the two groups; per-acute group resulting from rupture of vessels and acute group resulting from contusion.

  13. Cholestrol granuloma of the breast incidentally detected on dynamic abdominal CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Sun Hye; Lee, Eun Hye; Hong, Hyun Sook; Kwak, Jeong Ja [Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-01-15

    A breast cholesterol granuloma is an uncommon nodular breast lesion. We incidentally detected a persistently enhancing breast mass on the dynamic abdominal computed tomography (CT) of a 78-year-old woman. The mass decreased in diameter over 50 days following a core needle biopsy. This report is the first to describe the dynamic-enhanced CT features of a breast cholesterol granuloma.

  14. Changing spleen size after blunt abdominal trauma

    International Nuclear Information System (INIS)

    Goodman, L.R.; Aprahamian, C.

    1989-01-01

    The authors studied the incidence and significance of splenic enlargement on serial CT after abdominal trauma. Spleen size and density in 44 trauma patients were studied with serial, contrast-enhanced Ct. In 58% of the patients, ≥ 10% enlargement of the spleen was seen on follow-up scans. Ten patients had >50% enlargement. In several, the initial density of the spleen was less than that of the liver. Spleen density returned to normal on subsequent scans. Correlations between splenic changes and clinical parameters (such as blood replacement, hypotension, and various trauma indexes) were weak. The author's study indicated that serial splenic enlargement was a physiologic return to normal after major trauma, not a pathologic condition requiring splenectomy

  15. Blunt abdominal trauma in adults: role of CT in the diagnosis and management of visceral injuries. Part 1. Liver and spleen

    International Nuclear Information System (INIS)

    Becker, C.D.; Terrier, F.; Mentha, G.

    1998-01-01

    Computed tomography is now widely used in the initial diagnostic workup of adult trauma victims with suspected intra-abdominal injuries. We review the role of CT in the detection and management of blunt visceral injuries in two parts. In the first part we discuss general aspects of performing CT in the setting of abdominal trauma and the diagnostic findings of intra-abdominal hemorrhage and blunt hepatic and splenic injuries. Hepatic and splenic injuries can be detected by means of CT with a high accuracy. The vast majority of hepatic injuries can be successfully managed conservatively, even when CT demonstrates parenchymal damage of more than three segments and major hemoperitoneum. Delayed complications, e. g., formation of biloma or a false aneurysm, can be readily detected on repeat CT studies, although they are quite uncommon. The outcome of conservative treatment of splenic injuries remains unpredictable because delayed splenic rupture may occur even when initial CT shows only minor parenchymal lesions and little or no intraperitoneal hemorrhage. (orig.)

  16. Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms.

    Science.gov (United States)

    Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo

    2016-01-01

    We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  17. Socio-economic variation in CT scanning in Northern England, 1990-2002

    Directory of Open Access Journals (Sweden)

    Pearce Mark S

    2012-01-01

    Full Text Available Abstract Background Socio-economic status is known to influence health throughout life. In childhood, studies have shown increased injury rates in more deprived settings. Socio-economic status may therefore be related to rates of certain medical procedures, such as computed tomography (CT scans. This study aimed to assess socio-economic variation among young people having CT scans in Northern England between 1990 and 2002 inclusive. Methods Electronic data were obtained from Radiology Information Systems of all nine National Health Service hospital Trusts in the region. CT scan data, including sex, date of scan, age at scan, number and type of scans were assessed in relation to quintiles of Townsend deprivation scores, obtained from linkage of postcodes with census data, using χ2 tests and Spearman rank correlations. Results During the study period, 39,676 scans were recorded on 21,089 patients, with 38,007 scans and 19,485 patients (11344 male and 8132 female linkable to Townsend scores. The overall distributions of both scans and patients by quintile of Townsend deprivation scores were significantly different to the distributions of Townsend scores from the census wards included in the study (p Conclusions Social inequalities exist in the numbers of young people undergoing CT scans with those from deprived areas more likely to do so. This may reflect the rates of injuries in these individuals and implies that certain groups within the population may receive higher radiation doses than others due to medical procedures.

  18. Abdominal trauma

    International Nuclear Information System (INIS)

    Giordany, B.R.

    1985-01-01

    Abdominal injury is an important cause of morbidity and mortality in childhood. Ten percent of trauma-related deaths are due to abdominal injury. Thousands of children are involved in auto accidents annually; many suffer severe internal injury. Child abuse is a second less frequent but equally serious cause of internal abdominal injury. The descriptions of McCort and Eisenstein and their associates in the 1960s first brought to attention the frequency and severity of visceral injury as important manifestations of the child abuse syndrome. Blunt abdominal trauma often causes multiple injuries; in the past, many children have been subjected to exploratory surgery to evaluate the extent of possible hidden injury. Since the advent of noninvasive radiologic imaging techniques including radionuclide scans and ultrasound and, especially, computed tomography (CT), the radiologist has been better able to assess (accurately) the extent of abdominal injury and thus allow conservative therapy in many cases. Penetrating abdominal trauma occurs following gunshot wounds, stabbing, and other similar injury. This is fortunately, a relatively uncommon occurrence in most pediatric centers and will not be discussed specifically here, although many principles of blunt trauma diagnosis are valid for evaluation of penetrating abdominal trauma. If there is any question that a wound has extended intraperitonelly, a sinogram with water-soluble contrast material allows quick, accurate diagnosis. The presence of large amounts of free intraperitoneal gas suggests penetrating injury to the colon or other gas-containing viscus and is generally considered an indication for surgery

  19. The pictures of CT scan of gold pneumonitis

    International Nuclear Information System (INIS)

    Taguchi, Yoshio; Iwata, Takekuni; Kuroda, Yasumasa; Sadato, Norihiro; Tanemoto, Kiichiro; Adachi, Kazuhiko.

    1987-01-01

    We experienced two cases of gold pneumonitis and their interesting findings of CT scan. After the cessation of gold salt, both cases were treated with the corticosteroid, resulting in the disappearance of pulmonary manifestations and clearing of shadows on chest roentgenograms. The findings of CT scan on both cases were very interesting. They were the high density shadows along the bronchovascular bundles, the fluffy figures surroundings these shadows and band like shadows reached to the thoracic wall. We considered that each shadows were pathologically compatible with severe exudative changes of interstitial pneumonitis, shrinkage surroundings them and thickness of interlobular septum. (author)

  20. Automated lung volumetry from routine thoracic CT scans: how reliable is the result?

    Science.gov (United States)

    Haas, Matthias; Hamm, Bernd; Niehues, Stefan M

    2014-05-01

    Today, lung volumes can be easily calculated from chest computed tomography (CT) scans. Modern postprocessing workstations allow automated volume measurement of data sets acquired. However, there are challenges in the use of lung volume as an indicator of pulmonary disease when it is obtained from routine CT. Intra-individual variation and methodologic aspects have to be considered. Our goal was to assess the reliability of volumetric measurements in routine CT lung scans. Forty adult cancer patients whose lungs were unaffected by the disease underwent routine chest CT scans in 3-month intervals, resulting in a total number of 302 chest CT scans. Lung volume was calculated by automatic volumetry software. On average of 7.2 CT scans were successfully evaluable per patient (range 2-15). Intra-individual changes were assessed. In the set of patients investigated, lung volume was approximately normally distributed, with a mean of 5283 cm(3) (standard deviation = 947 cm(3), skewness = -0.34, and curtosis = 0.16). Between different scans in one and the same patient the median intra-individual standard deviation in lung volume was 853 cm(3) (16% of the mean lung volume). Automatic lung segmentation of routine chest CT scans allows a technically stable estimation of lung volume. However, substantial intra-individual variations have to be considered. A median intra-individual deviation of 16% in lung volume between different routine scans was found. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  1. Kaposi sarcoma and lymphadenopathy syndrome: limitations of abdominal CT in acquired immunodeficiency syndrome

    International Nuclear Information System (INIS)

    Moon, K.L. Jr.; Federle, M.P.; Abrams, D.I.; Volberding, P.; Lewis, B.J.

    1984-01-01

    Abdominal computed tomography (CT) was performed in 31 patients with Kaposi sarcoma (KS) related to acquired immunodeficiency syndrome (AIDS), three patients with classic KS, and 12 patients with the newly described lymphadenopathy syndrome (LNS). The frequency, distribution, and appearance of lymphadenopathy and splenomegaly were similar in the AIDS-related KS and LNS groups. Rectal and perirectal disease was identified in 86% of homosexual men studied; rectal KS could not be distinguished from proctitis on CT criteria alone. No CT abnormalities were seen in patients with classic KS. The CT demonstration of retroperitoneal, mesenteric, or pelvic adenopathy or of rectal or perirectal disease in patients with AIDS-related KS is not necessarily indicative of widespread involvement with the disease

  2. Spontaneous spinal epidural hematoma diagnosed by CT scan

    International Nuclear Information System (INIS)

    Abumiya, Takeo; Isu, Toyohiko; Iwasaki, Yoshinobu; Akino, Minoru; Abe, Hiroshi

    1985-01-01

    A case of spinal epidural hematoma diagnosed by CT scan is reported. A 58-year-old man was admitted on June 18, 1984. He had had a sudden onset of severe low-back pain 7 days before admission and had developed paraparesis and numbness of the lower limbs 4 day before admission. Physical examination revealed weakness in the lower limbs, with the reflexes there decreased. The Babinski reflex and the Chaddock reflex were, however, present on both sides. Sensory disturbances were noted below L 2 . Urinary incontinence was present, too. Metrizamide myelography revealed an epidural mass which was located from the power part of T 11 to the upper part of L 2 . A CT scan revealed a biconvex, relatively high-density mass in the posterior spinal canal. On the day of admission, a laminectomy was performed from T 11 to L 1 , and the epidural hematoma was evacuated. The postoperative course was uneventful. Spinal epidural hematoma is uncommon. A CT scan can be used for an early diagnosis of this lesion. According to the review of the CT findings in 15 reported cases, including our case, CT reveals a smoothly marginated biconvex homogeneous density mass. The density of the hematoma decreases with the time. An acute type (within 3 days) is high-density, while a chronic type has a relatively high or isodensity. The acute type is easily differentiated from other epidural masses, such as a herniated disc, an epidural abscess, and an epidural tumor. On the other hand, the diagnosis of the chronic type is not always easy. (author)

  3. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  4. CT Scanning in Identification of Sheep Cystic Echinococcosis.

    Science.gov (United States)

    Mao, Rui; Qi, Hongzhi; Pei, Lei; Hao, Jie; Dong, Jian; Jiang, Tao; Ainiwaer, Abudula; Shang, Ge; Xu, Lin; Shou, Xi; Zhang, Songan; Wu, Ge; Lu, Pengfei; Bao, Yongxing; Li, Haitao

    2017-01-01

    We aim to determine the efficiency of CT in identification of cystic echinococcosis in sheep. Fifty-three sheep with liver cysts confirmed by ultrasonography were subject to CT scan to evaluate the number, size, and type of the cysts in liver and lung, confirmed using necropsy. The correlation of numbers between liver cysts and lung cysts was calculated using Pearson analysis. Necropsy indicated a 98% consensus on size, location, number, and activity compared with CT scan. The viable cysts were 53.1% and 50.6% in the liver and lung, respectively. Among the cysts in liver, 35.5%, 9.5%, 5.7%, 10.2%, and 39.1% were Types CE1, CE2, CE3, CE4, and CE5, respectively. The cysts in the lungs, 17.4%, 26.9%, 12.1%, 11.6%, and 32.1%, were Types CE1, CE2, CE3, CE4, and CE5, respectively. A significant correlation was noticed between the number of cysts in liver and those in lung ( R = 0.770, P < 0.001). CT scan is a suitable tool in determining the size and type of cystic hydatid cysts in both liver and lung of sheep. A significant correlation was noticed between the numbers in liver and lung, indicating that lung infection was likely due to the expansion of liver cyst burden pressure.

  5. Metastasectomy of Abdominal Wall Lesions due to Prostate Cancer Detected Through PET/CT Gallium 68-PMSA: First Case Report

    Directory of Open Access Journals (Sweden)

    Claudia Ochoa

    2017-05-01

    Full Text Available Introducing the topic of abdominal wall metastasis secondary to prostate cancer with a reminder of the disease's rarity, being the first published case. This article is about a 66 year old patient diagnosed with prostate cancer [cT2aNxMx iPSA: 5,6 ng/ml Gleason 3+3, (Grade 1 Group], treated with radical prostatectomy as well as accompanied with amplified pelvic lymphadenectomy, who subsequently presented metastatic lesions to the abdominal wall diagnosed with PET/CT Gallium 68-PMSA technique and treated with abdominal metastasectomy with adequate short term results.

  6. Abdominal CT predictors of fibrosis in patients with chronic pancreatitis undergoing surgery

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Amitasha; Afghani, Elham [Johns Hopkins Medical Institutions, Division of Gastroenterology, Baltimore, MD (United States); Singh, Vikesh K. [Johns Hopkins Medical Institutions, Division of Gastroenterology, Baltimore, MD (United States); Johns Hopkins Medical Institutions, Pancreatitis Center, Baltimore, MD (United States); Cruise, Michael; Matsukuma, Karen [Johns Hopkins Medical Institutions, Department of Pathology, Baltimore, MD (United States); Ali, Sumera; Raman, Siva P.; Fishman, Elliot K. [Johns Hopkins Medical Institutions, The Russel H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Andersen, Dana K. [National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD (United States); Makary, Martin A. [Johns Hopkins Medical Institutions, Department of Surgery, Baltimore, MD (United States); Johns Hopkins Medical Institutions, Pancreatitis Center, Baltimore, MD (United States); Zaheer, Atif [Johns Hopkins Medical Institutions, The Russel H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Johns Hopkins Medical Institutions, Pancreatitis Center, Baltimore, MD (United States); Johns Hopkins Medical Institutions, Baltimore, MD (United States)

    2015-05-01

    To determine which abdominal CT findings predict severe fibrosis and post-operative pain relief in chronic pancreatitis (CP). Pre-operative abdominal CTs of 66 patients (mean age 52 ± 12 years, 53 % males) with painful CP who underwent the Whipple procedure (n = 32), Frey procedure (n = 32) or pancreatic head biopsy (n = 2), between 1/2003-3/2014, were evaluated. CT was evaluated for parenchymal calcifications, intraductal calculi, main pancreatic duct dilation (>5 mm), main pancreatic duct stricture, and abnormal side branch(es). The surgical histopathology was graded for fibrosis. CT findings were evaluated as predictors of severe fibrosis and post-operative pain relief using regression and area under receiver operating curve (AUC) analysis. Thirty-eight (58 %) patients had severe fibrosis. Parenchymal calcification(s) were an independent predictor of severe fibrosis (p = 0.03), and post-operative pain relief over a mean follow-up of 1-year (p = 0.04). Presence of >10 parenchymal calcifications had higher predictive accuracy for severe fibrosis than 1-10 parenchymal calcification(s) (AUC 0.88 vs. 0.59, p = 0.003). The predictive accuracy of >10 versus 1-10 parenchymal calcifications increased after adjusting for all other CT findings (AUC 0.89 vs. 0.63, p = 0.01). Parenchymal calcification(s) independently predict severe fibrosis and are significantly associated with post-operative pain relief in CP. The presence of >10 parenchymal calcifications is a better predictor of severe fibrosis than 1-10 parenchymal calcification(s). (orig.)

  7. Abdominal CT predictors of fibrosis in patients with chronic pancreatitis undergoing surgery

    International Nuclear Information System (INIS)

    Sinha, Amitasha; Afghani, Elham; Singh, Vikesh K.; Cruise, Michael; Matsukuma, Karen; Ali, Sumera; Raman, Siva P.; Fishman, Elliot K.; Andersen, Dana K.; Makary, Martin A.; Zaheer, Atif

    2015-01-01

    To determine which abdominal CT findings predict severe fibrosis and post-operative pain relief in chronic pancreatitis (CP). Pre-operative abdominal CTs of 66 patients (mean age 52 ± 12 years, 53 % males) with painful CP who underwent the Whipple procedure (n = 32), Frey procedure (n = 32) or pancreatic head biopsy (n = 2), between 1/2003-3/2014, were evaluated. CT was evaluated for parenchymal calcifications, intraductal calculi, main pancreatic duct dilation (>5 mm), main pancreatic duct stricture, and abnormal side branch(es). The surgical histopathology was graded for fibrosis. CT findings were evaluated as predictors of severe fibrosis and post-operative pain relief using regression and area under receiver operating curve (AUC) analysis. Thirty-eight (58 %) patients had severe fibrosis. Parenchymal calcification(s) were an independent predictor of severe fibrosis (p = 0.03), and post-operative pain relief over a mean follow-up of 1-year (p = 0.04). Presence of >10 parenchymal calcifications had higher predictive accuracy for severe fibrosis than 1-10 parenchymal calcification(s) (AUC 0.88 vs. 0.59, p = 0.003). The predictive accuracy of >10 versus 1-10 parenchymal calcifications increased after adjusting for all other CT findings (AUC 0.89 vs. 0.63, p = 0.01). Parenchymal calcification(s) independently predict severe fibrosis and are significantly associated with post-operative pain relief in CP. The presence of >10 parenchymal calcifications is a better predictor of severe fibrosis than 1-10 parenchymal calcification(s). (orig.)

  8. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kim, Dong Wook; Hong, Jung Hwa [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2014-12-15

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  9. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    International Nuclear Information System (INIS)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung; Yoon, Choon-Sik; Kim, Dong Wook; Hong, Jung Hwa

    2014-01-01

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  10. Helical CT scan for emergent patients with cerebrovascular diseases

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio

    1995-01-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author)

  11. Helical CT scan for emergent patients with cerebrovascular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Sato, Naoki; Nakano, Masayuki; Watanabe, Youichi; Kodama, Namio [Fukushima Medical Coll. (Japan)

    1995-08-01

    We studied 44 emergent patients with cerebrovascular diseases (18 cases of subarachnoid hemorrhage, 15 of occlusive lesions, 7 of intracerebral hematoma and 4 of suspected subarachnoid hemorrhage) using helical CT scan. The helical CT scan was performed with contrast medium at a rate of 3 ml/sec with a delay of 20 sec, and was carried out before conventional angiography. The reconstruction time of 3D-CTA was within 10 min. We were able to obtain findings for the lesion on 3D-CTA before those on conventional angiography. The 3D-CTA yielded excellent images of the vascular structures and anatomical relationships of the aneurysm, its neck and parent artery, and surrounding arteries. However, it proved difficult to visualize vessels of less than 1 mm in diameter, especially the perforating arteries. In occlusive diseases, the degree of stenosis depended on the changes in CT number threshold: at present, evaluations of the lesions should be made by conventional angiography. 3D-CTA using helical CT scan can thus be applied for emergent patients with cerebrovascular diseases. Surgical simulation images of 3D-CTA were especially useful at the time of operation. (author).

  12. Abdominal CT Does Not Improve Outcome for Children with Suspected Acute Appendicitis

    Directory of Open Access Journals (Sweden)

    Danielle I. Miano

    2015-12-01

    Full Text Available Introduction: Acute appendicitis in children is a clinical diagnosis, which often requires preoperative confirmation with either ultrasound (US or computed tomography (CT studies. CTs expose children to radiation, which may increase the lifetime risk of developing malignancy. US in the pediatric population with appropriate clinical follow up and serial exam may be an effective diagnostic modality for many children without incurring the risk of radiation. The objective of the study was to compare the rate of appendiceal rupture and negative appendectomies between children with and without abdominal CTs; and to evaluate the same outcomes for children with and without USs to determine if there were any associations between imaging modalities and outcomes. Methods: We conducted a retrospective chart review including emergency department (ED and inpatient records from 1/1/2009–2/31/2010 and included patients with suspected acute appendicitis. Results: 1,493 children, aged less than one year to 20 years, were identified in the ED with suspected appendicitis. These patients presented with abdominal pain who had either a surgical consult or an abdominal imaging study to evaluate for appendicitis, or were transferred from an outside hospital or primary care physician office with the stated suspicion of acute appendicitis. Of these patients, 739 were sent home following evaluation in the ED and did not return within the subsequent two weeks and were therefore presumed not to have appendicitis. A total of 754 were admitted and form the study population, of which 20% received a CT, 53% US, and 8% received both. Of these 57%, 95% CI [53.5,60.5] had pathology-proven appendicitis. Appendicitis rates were similar for children with a CT (57%, 95% CI [49.6,64.4] compared to those without (57%, 95% CI [52.9,61.0]. Children with perforation were similar between those with a CT (18%, 95% CI [12.3,23.7] and those without (13%, 95% CI [10.3,15.7]. The proportion of

  13. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    International Nuclear Information System (INIS)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub; Yoon, Ji Young

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16±0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51±0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52±0.25, while in 21 non-traumatic patients it was 1.15±0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT

  14. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub [Dongguk Univ. College of Medicine, Pohang (Korea, Republic of); Yoon, Ji Young [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16{+-}0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51{+-}0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52{+-}0.25, while in 21 non-traumatic patients it was 1.15{+-}0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT.

  15. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings

    International Nuclear Information System (INIS)

    Kramer, E.L.; Noz, M.E.; Sanger, J.J.; Megibow, A.J.; Maguire, G.Q.

    1989-01-01

    To enhance the information provided by computed tomography (CT) and single photon emission computed tomography (SPECT) performed with radiolabeled, anti-carcinoembryonic antigen monoclonal antibody (MoAb), the authors performed fusion of these types of images from eight subjects with suspected colorectal adenocarcinoma. Section thickness and pixel size of the two studies were matched, coordinates of corresponding points from each study were identified, and CT sections were translated, rotated, and reprojected to match the corresponding SPECT scans. The CT-SPECT fusion enabled identification of anatomic sites of tumor-specific MoAb accumulation in four cases, showed non-specific MoAb accumulation in two, and helped confirm information only suggested by the two studies separately in one

  16. Isolated free intra-abdominal fluid on CT in blunt trauma: The continued diagnostic dilemma.

    Science.gov (United States)

    Kong, Victor Y; Jeetoo, Damon; Naidoo, Leah C; Oosthuizen, George V; Clarke, Damian L

    2015-01-01

    The clinical significance of isolated free fluid (FF) without solid organ injury on computed to- mography (CT) continues to pose significant dilemma in the management of patients with blunt abdominal trauma (BAT). We reviewed the incidence of FF and the clinical outcome amongst patients with blunt abdominal trauma in a metropolitan trauma service in South Africa. We performed a retrospective study of 121 consecutive CT scans over a period of 12 months to determine the incidence of isolated FF and the clinical outcome of patients managed in a large metropolitan trauma service. Of the 121 CTs, FF was identified in 36 patients (30%). Seven patients (6%) had isolated FF. Of the 29 patients who had free fluid and associated organ injuries, 33 organ injuries were identified. 86% (25/ 29) of all 29 patients had a single organ injury and 14% had multiple organ injuries. There were 26 solid organ injuries and 7 hollow organ injuries. The 33 organs injured were: spleen, 12; liver, 8; kidney, 5; pancreas, 2; small bowel, 4; duodenum, 1. Six (21%) patients required operative management for small bowel perforations in 4 cases and pancreatic tail injury in 2 cases. All 7 patients with isolated FF were initially observed, and 3 (43%) were eventually subjected to operative intervention. They were found to have an intra-peritoneal bladder rupture in 1 case, a non-expanding zone 3 haematoma in 1 case, and a negative laparotomy in 1 case. Four (57%) patients were successfully managed without surgical interventions. Isolated FF is uncommon and the clinical significance remains unclear. Provided that reli- able serial physical examination can be performed by experienced surgeons, an initial non-operative approach should be considered.

  17. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    International Nuclear Information System (INIS)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-01-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens

  18. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Science.gov (United States)

    Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús

    2014-11-01

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  19. Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute

    Energy Technology Data Exchange (ETDEWEB)

    Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico); Reynoso-Mejía, Alberto [Unidad de Imagen Molecular PET/CT, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F., Mexico and Departamento de Neuroimagen, Instituto Nacional de (Mexico); Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús [Departamento de Neuroimagen, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Insurgentes Sur 3877 Col. La Fama, 14269, México D.F. (Mexico)

    2014-11-07

    In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.

  20. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  1. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  2. CT and fluoroscopy guided celiac ganglion block

    International Nuclear Information System (INIS)

    Lim, Sun Kyung; Kwon, Dae Ik; Ahn, Hyup; Kim, Jong Il; Kim, Byung Young; Lee, Jong Gil

    1994-01-01

    To evaluate the effects and usefulness of fluoroscopy guided celiac ganglion block after marking of needle path with CT scan. Celiac ganglion block with 100% ethyl alcohol was performed in 50 cancer patients who were inoperable and had intractable abdominal pain. Duration and degree of pain relief after the procedure and its complication were analyzed. Early pain relief was observed in 98% and long term relief in 68% without serious complication. Fluoroscopy guided celiac ganglion block after marking of needle path with CT scan was a safe and valuable procedure in relieving intractable pain in terminal cancer patients and reduced the time in the CT room

  3. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  4. Blunt abdominal trauma in adults: role of CT in the diagnosis and management of visceral injuries. Part 1. Liver and spleen

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.D.; Terrier, F. [Department of Radiology, Division of Diagnostic and Interventional Radiology, Geneva University Hospital, Geneva (Switzerland); Mentha, G. [Department of Surgery, Division of Abdominal Surgery, Geneva University Hospital, Geneva (Switzerland)

    1998-05-01

    Computed tomography is now widely used in the initial diagnostic workup of adult trauma victims with suspected intra-abdominal injuries. We review the role of CT in the detection and management of blunt visceral injuries in two parts. In the first part we discuss general aspects of performing CT in the setting of abdominal trauma and the diagnostic findings of intra-abdominal hemorrhage and blunt hepatic and splenic injuries. Hepatic and splenic injuries can be detected by means of CT with a high accuracy. The vast majority of hepatic injuries can be successfully managed conservatively, even when CT demonstrates parenchymal damage of more than three segments and major hemoperitoneum. Delayed complications, e. g., formation of biloma or a false aneurysm, can be readily detected on repeat CT studies, although they are quite uncommon. The outcome of conservative treatment of splenic injuries remains unpredictable because delayed splenic rupture may occur even when initial CT shows only minor parenchymal lesions and little or no intraperitoneal hemorrhage. (orig.) With 11 figs., 5 tabs., 64 refs.

  5. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  6. Estimating local noise power spectrum from a few FBP-reconstructed CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Rongping, E-mail: rongping.zeng@fda.hhs.gov; Gavrielides, Marios A.; Petrick, Nicholas; Sahiner, Berkman; Li, Qin; Myers, Kyle J. [Division of Imaging, Diagnostics, and Software Reliability, Office of Science and Engineering Laboratories, CDRH, FDA, Silver Spring, Maryland 20993 (United States)

    2016-01-15

    Purpose: Traditional ways to estimate 2D CT noise power spectrum (NPS) involve an ensemble average of the power spectrums of many noisy scans. When only a few scans are available, regions of interest are often extracted from different locations to obtain sufficient samples to estimate the NPS. Using image samples from different locations ignores the nonstationarity of CT noise and thus cannot accurately characterize its local properties. The purpose of this work is to develop a method to estimate local NPS using only a few fan-beam CT scans. Methods: As a result of FBP reconstruction, the CT NPS has the same radial profile shape for all projection angles, with the magnitude varying with the noise level in the raw data measurement. This allows a 2D CT NPS to be factored into products of a 1D angular and a 1D radial function in polar coordinates. The polar separability of CT NPS greatly reduces the data requirement for estimating the NPS. The authors use this property and derive a radial NPS estimation method: in brief, the radial profile shape is estimated from a traditional NPS based on image samples extracted at multiple locations. The amplitudes are estimated by fitting the traditional local NPS to the estimated radial profile shape. The estimated radial profile shape and amplitudes are then combined to form a final estimate of the local NPS. We evaluate the accuracy of the radial NPS method and compared it to traditional NPS methods in terms of normalized mean squared error (NMSE) and signal detectability index. Results: For both simulated and real CT data sets, the local NPS estimated with no more than six scans using the radial NPS method was very close to the reference NPS, according to the metrics of NMSE and detectability index. Even with only two scans, the radial NPS method was able to achieve a fairly good accuracy. Compared to those estimated using traditional NPS methods, the accuracy improvement was substantial when a few scans were available

  7. Evaluation of reduced-dose CT for acute non-traumatic abdominal pain: evaluation of diagnostic accuracy in comparison to standard-dose CT.

    Science.gov (United States)

    Othman, Ahmed E; Bongers, Malte Niklas; Zinsser, Dominik; Schabel, Christoph; Wichmann, Julian L; Arshid, Rami; Notohamiprodjo, Mike; Nikolaou, Konstantin; Bamberg, Fabian

    2018-01-01

    Background Patients with acute non-traumatic abdominal pain often undergo abdominal computed tomography (CT). However, abdominal CT is associated with high radiation exposure. Purpose To evaluate diagnostic performance of a reduced-dose 100 kVp CT protocol with advanced modeled iterative reconstruction as compared to a linearly blended 120 kVp protocol for assessment of acute, non-traumatic abdominal pain. Material and Methods Two radiologists assessed 100 kVp and linearly blended 120 kVp series of 112 consecutive patients with acute non-traumatic pain (onset diagnostic confidence. Both 100 kVp and linearly blended 120 kVp series were quantitatively evaluated regarding radiation dose and image noise. Comparative statistics and diagnostic accuracy was calculated using receiver operating curve (ROC) statistics, with final clinical diagnosis/clinical follow-up as reference standard. Results Image quality was high for both series without detectable significant differences ( P = 0.157). Image noise and artifacts were rated low for both series but significantly higher for 100 kVp ( P ≤ 0.021). Diagnostic accuracy was high for both series (120 kVp: area under the curve [AUC] = 0.950, sensitivity = 0.958, specificity = 0.941; 100 kVp: AUC ≥ 0.910, sensitivity ≥ 0.937, specificity = 0.882; P ≥ 0.516) with almost perfect inter-rater agreement (Kappa = 0.939). Diagnostic confidence was high for both dose levels without significant differences (100 kVp 5, range 4-5; 120 kVp 5, range 3-5; P = 0.134). The 100 kVp series yielded 26.1% lower radiation dose compared with the 120 kVp series (5.72 ± 2.23 mSv versus 7.75 ± 3.02 mSv, P diagnostic accuracy for the assessment of acute non-traumatic abdominal pain.

  8. Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung

    International Nuclear Information System (INIS)

    Lu Wei; Low, Daniel A.; Parikh, Parag J.; Nystrom, Michelle M.; El Naqa, Issam M.; Wahab, Sasha H.; Handoko, Maureen; Fooshee, David; Bradley, Jeffrey D.

    2005-01-01

    An important consideration in four-dimensional CT scanning is the selection of a breathing metric for sorting the CT data and modeling internal motion. This study compared two noninvasive breathing metrics, spirometry and abdominal height, against internal air content, used as a surrogate for internal motion. Both metrics were shown to be accurate, but the spirometry showed a stronger and more reproducible relationship than the abdominal height in the lung. The abdominal height was known to be affected by sensor placement and patient positioning while the spirometer exhibited signal drift. By combining these two, a normalization of the drift-free metric to tidal volume may be generated and the overall metric precision may be improved

  9. Automatic blood vessel based-liver segmentation using the portal phase abdominal CT

    Science.gov (United States)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2018-02-01

    Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

  10. CT scan of bacterial and aseptic meningitis

    International Nuclear Information System (INIS)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role. (author)

  11. Fat deposition in the urinary bladder wall: Incidental finding on abdominal computed tomography: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Ho; Moon, Sung Kyoung; Ahn, Sung Eun; Park, Seong Jin; Lim, Joo Won; Lee, Dong Ho [Dept. of Radiology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2015-02-15

    In a computed tomography (CT) scan, fat deposition in the urinary bladder wall is seen as a linear hypoattenuating band surrounded by soft tissue density. It is uncommon, but is often seen in normal cases. However, there is no report of fat deposition in the urinary bladder wall in Korea. The authors encountered a 62-year-old male patient who showed an incidental hypoattenuating band in the urinary bladder wall on abdominal CT. The patient showed no clinical signs related to fat deposition in the urinary bladder wall. When the patient's previous abdominal CT was retrospectively reviewed, the same CT finding was seen. This linear hypoattenuating band within the urinary bladder wall should be considered as a normal CT finding, although it is uncommon.

  12. Practical human abdominal fat imaging utilizing electrical impedance tomography.

    Science.gov (United States)

    Yamaguchi, T; Maki, K; Katashima, M

    2010-07-01

    The fundamental cause of metabolic syndrome is thought to be abdominal obesity. Accurate diagnosis of abdominal obesity can be done by an x-ray computed tomography (CT) scan. But CT is expensive, bulky and entails the risks involved with radiation. To overcome such disadvantages, we attempted to develop a measuring device that could apply electrical impedance tomography to abdominal fat imaging. The device has 32 electrodes that can be attached to a subject's abdomen by a pneumatic mechanism. That way, electrode position data can be acquired simultaneously. An applied alternating current of 1.0 mArms was used at a frequency of 500 kHz. Sensed voltage data were carefully filtered to remove noise and processed to satisfy the reciprocal theorem. The image reconstruction software was developed concurrently, applying standard finite element methods and the Marquardt method to solve the mathematical inverse problem. The results of preliminary experiments showed that abdominal subcutaneous fat and the muscle surrounding the viscera could be imaged in humans. While our imaging of visceral fat was not of sufficient quality, it was suggested that we will be able to develop a safe and practical abdominal fat scanner through future improvements.

  13. Practical human abdominal fat imaging utilizing electrical impedance tomography

    International Nuclear Information System (INIS)

    Yamaguchi, T; Katashima, M; Maki, K

    2010-01-01

    The fundamental cause of metabolic syndrome is thought to be abdominal obesity. Accurate diagnosis of abdominal obesity can be done by an x-ray computed tomography (CT) scan. But CT is expensive, bulky and entails the risks involved with radiation. To overcome such disadvantages, we attempted to develop a measuring device that could apply electrical impedance tomography to abdominal fat imaging. The device has 32 electrodes that can be attached to a subject's abdomen by a pneumatic mechanism. That way, electrode position data can be acquired simultaneously. An applied alternating current of 1.0 mArms was used at a frequency of 500 kHz. Sensed voltage data were carefully filtered to remove noise and processed to satisfy the reciprocal theorem. The image reconstruction software was developed concurrently, applying standard finite element methods and the Marquardt method to solve the mathematical inverse problem. The results of preliminary experiments showed that abdominal subcutaneous fat and the muscle surrounding the viscera could be imaged in humans. While our imaging of visceral fat was not of sufficient quality, it was suggested that we will be able to develop a safe and practical abdominal fat scanner through future improvements

  14. Dosimetry in abdominal imaging by 6-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Sonia Isabel [Hospital de Faro, EPE (Portugal); Abrantes, Antonio Fernando; Ribeiro, Luis Pedro; Almeida, Rui Pedro Pereira [University of Algarve (Portugal). School of Health. Dept. of Radiology

    2012-11-15

    Objective: To determine the effective dose in abdominal computed tomography imaging and to study the influence of patients' characteristics on the received dose. Materials and Methods: Dose values measurements were performed with an ionization chamber on phantoms to check the agreement between dose values and those presented by the computed tomography apparatus, besides their compliance with the recommended reference dose levels. Later, values of dose received by physically able patients submitted to abdominal computed tomography (n = 100) were measured and correlated with their anthropometric characteristics. Finally, the dose to organs was simulated with the Monte Carlo method using the CT-Expo V 1.5 software, and the effect of automatic exposure control on such examinations. Results: The main characteristics directly influencing the dose include the patients' body mass, abdominal perimeter and body mass index, whose correlation is linear and positive. Conclusion: The radiation dose received from abdominal CT scans depends on some patient's characteristics, and it is important to adjust the acquisition parameters to their dimensions (author)

  15. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  16. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  17. Automatic Segmentation of Abdominal Fat in MRI-Scans, Using Graph-Cuts and Image Derived Energies

    DEFF Research Database (Denmark)

    Christensen, Anders Nymark; Larsen, Christian Thode; Mandrup Jensen, Camilla Maria

    2017-01-01

    For many clinical studies changes in the abdominal distribution of fat is an important measure. However, the segmentation of abdominal fat in MRI scans is both difficult and time consuming using manual methods. We present here an automatic and flexible software package, that performs both bias fi...

  18. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  19. Detailed Review of CT Scans Aids Assessment of the Airway in ...

    African Journals Online (AJOL)

    Two cases are presented that illustrate the importance of information gained from CT scans of the head and neck taken in patients presenting for maxillo-facial surgery. The first case involved a 25 year old with a massive tumour filling his mouth. Pre-operative assessment was done without reviewing the CT scans of his ...

  20. Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Vorona, Gregory A. [The Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Allegheny General Hospital, Department of Radiology, Pittsburgh, PA (United States); Ceschin, Rafael C.; Clayton, Barbara L.; Sutcavage, Tom; Tadros, Sameh S.; Panigrahy, Ashok [The Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States)

    2011-09-15

    The use of the adaptive statistical iterative reconstruction (ASIR) algorithm has been shown to reduce radiation doses in adults undergoing abdominal CT studies while preserving image quality. To our knowledge, no studies have been done to validate the use of ASIR in children. To retrospectively evaluate differences in radiation dose and image quality in pediatric CT abdominal studies utilizing 40% ASIR compared with filtered-back projection (FBP). Eleven patients (mean age 8.5 years, range 2-17 years) had separate 40% ASIR and FBP enhanced abdominal CT studies on different days between July 2009 and October 2010. The ASIR studies utilized a 38% mA reduction in addition to our pediatric protocol mAs. Study volume CT dose indexes (CTDI{sub vol}) and dose-length products (DLP) were recorded. A consistent representative image was obtained from each study. The images were independently evaluated by two radiologists in a blinded manner for diagnostic utility, image sharpness and image noise. The average CTDI{sub vol} and DLP for the 40% ASIR studies were 4.25 mGy and 185.04 mGy-cm, compared with 6.75 mGy and 275.79 mGy-cm for the FBP studies, representing 37% and 33% reductions in both, respectively. The radiologists' assessments of subjective image quality did not demonstrate any significant differences between the ASIR and FBP images. In our experience, the use of 40% ASIR with a 38% decrease in mA lowers the radiation dose for children undergoing enhanced abdominal examinations by an average of 33%, while maintaining diagnostically acceptable images. (orig.)

  1. Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study

    International Nuclear Information System (INIS)

    Vorona, Gregory A.; Ceschin, Rafael C.; Clayton, Barbara L.; Sutcavage, Tom; Tadros, Sameh S.; Panigrahy, Ashok

    2011-01-01

    The use of the adaptive statistical iterative reconstruction (ASIR) algorithm has been shown to reduce radiation doses in adults undergoing abdominal CT studies while preserving image quality. To our knowledge, no studies have been done to validate the use of ASIR in children. To retrospectively evaluate differences in radiation dose and image quality in pediatric CT abdominal studies utilizing 40% ASIR compared with filtered-back projection (FBP). Eleven patients (mean age 8.5 years, range 2-17 years) had separate 40% ASIR and FBP enhanced abdominal CT studies on different days between July 2009 and October 2010. The ASIR studies utilized a 38% mA reduction in addition to our pediatric protocol mAs. Study volume CT dose indexes (CTDI vol ) and dose-length products (DLP) were recorded. A consistent representative image was obtained from each study. The images were independently evaluated by two radiologists in a blinded manner for diagnostic utility, image sharpness and image noise. The average CTDI vol and DLP for the 40% ASIR studies were 4.25 mGy and 185.04 mGy-cm, compared with 6.75 mGy and 275.79 mGy-cm for the FBP studies, representing 37% and 33% reductions in both, respectively. The radiologists' assessments of subjective image quality did not demonstrate any significant differences between the ASIR and FBP images. In our experience, the use of 40% ASIR with a 38% decrease in mA lowers the radiation dose for children undergoing enhanced abdominal examinations by an average of 33%, while maintaining diagnostically acceptable images. (orig.)

  2. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  3. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  4. CT study of pancreatic diseases with modified dynamic scanning

    International Nuclear Information System (INIS)

    Qian Minghui; Zhu Guangying

    1990-01-01

    Experience of 20 cases modified dynamic CT scanning is presented. With a slight increased X-ray tube burden, it is possible to investigate tumor blood supply and find small pancreatic insulinoma with this method. The capsular sign typical for chronic traumatic pancreatic hematoma on CT is presented

  5. Dental-CT: image quality and absorbed radiation dose of different scan protocols

    International Nuclear Information System (INIS)

    Schorn, C.; Alamo, L.; Funke, M.; Grabbe, E.; Visser, H.; Hermann, K.P.

    1999-01-01

    Purpose: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. Methods: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). Results: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. Conclusions: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT. (orig.) [de

  6. Clinical implications of immediate or later periportal edema in MS-CT trauma scans: surrogate parameter of intravenous fluid status and venous congestion.

    Science.gov (United States)

    Kleber, C; Buschmann, C T

    2013-06-01

    Periportal edema (PPE) of the liver in multislice computed tomography (MS-CT) scans that develops immediately (primary PPE [pPPE]) or later (secondary PPE [sPPE]) is not uncommon in severe trauma patients. Although PPE may serve as a marker for blunt abdominal trauma (22-31 % of cases), distinct causes and clinical implications of PPE are unclear. We analyzed the incidence of pPPE and sPPE in 68 MS-CT scans in severe trauma patients (2007-2009). Exclusion criteria were severely burned patients and patients with preexistent liver diseases predisposing to PPE. We divided PPE+ patients into two subpopulations-either initial/primary PPE (pPPE+) or later/secondary PPE (sPPE+). Further patient data were collected and statistically analyzed. PPE+ was found in 27.9 % (n = 19). Females predominated (p = 0.01), and PPE+ patients presented with a significantly better pH at admission (p = 0.008). The total amount of volume resuscitation (1,983 ± 1,155 ml; p = 0.02) and crystalloids (1,117 ± 796 ml; p = 0.006) administered before MS-CT scans was significantly higher in PPE+, whereas the amount of administered colloids (797 ± 640 ml) showed no significant difference in both groups. PPE+ was not associated with further patient data, i.e., trauma mechanism, injury severity, prognosis-relevant factors, adverse clinical events, or mortality. pPPE+ in MS-CT may serve as a surrogate parameter for intravenous volume load and/or venous congestion, and sPPE+ may also indicate venous congestion and right heart failure after severe trauma. In severe trauma patients with pPPE+/sPPE+ in MS-CT scans, causes of PPE relating to intravenous fluid overload and/or venous congestion should be excluded or treated.

  7. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  8. Clinical application of the helical CT in patients who are unable to hold their breath

    International Nuclear Information System (INIS)

    Toyama, Yoshihiro; Kimura, Naruhide; Ohkawa, Motoomi; Tanabe, Masatada.

    1997-01-01

    We performed helical CT in eighteen patients who were unable to hold their breath for 10 chest and 8 abdominal regions. Although there were respiratory artifacts in three cases, we could obtain the useful clinical information in all cases. In our experimental examinations, CT value of the phantom by helical scan was lower than that by conventional scan without movement of the phantom. With movement of it, the CT value was further lowered by either scan method, but the lowered rate was smaller by helical scan as the movement becomes faster. We consider that helical CT can be applied to patients who were unable to hold their breath. (author)

  9. Developing optimized CT scan protocols: Phantom measurements of image quality

    International Nuclear Information System (INIS)

    Zarb, Francis; Rainford, Louise; McEntee, Mark F.

    2011-01-01

    Purpose: The increasing frequency of computerized tomography (CT) examinations is well documented, leading to concern about potential radiation risks for patients. However, the consequences of not performing the CT examination and missing injuries and disease are potentially serious, impacting upon correct patient management. The ALARA principle of dose optimization must be employed for all justified CT examinations. Dose indicators displayed on the CT console as either CT dose index (CTDI) and/or dose length product (DLP), are used to indicate dose and can quantify improvements achieved through optimization. Key scan parameters contributing to dose have been identified in previous literature and in previous work by our group. The aim of this study was to optimize the scan parameters of mA; kV and pitch, whilst maintaining image quality and reducing dose. This research was conducted using psychophysical image quality measurements on a CT quality assurance (QA) phantom establishing the impact of dose optimization on image quality parameters. Method: Current CT scan parameters for head (posterior fossa and cerebrum), abdomen and chest examinations were collected from 57% of CT suites available nationally in Malta (n = 4). Current scan protocols were used to image a Catphan 600 CT QA phantom whereby image quality was assessed. Each scan parameter: mA; kV and pitch were systematically reduced until the contrast resolution (CR), spatial resolution (SR) and noise were significantly lowered. The Catphan 600 images, produced by the range of protocols, were evaluated by 2 expert observers assessing CR, SR and noise. The protocol considered as the optimization threshold was just above the setting that resulted in a significant reduction in CR and noise but not affecting SR at the 95% confidence interval. Results: The limit of optimization threshold was determined for each CT suite. Employing optimized parameters, CTDI and DLP were both significantly reduced (p ≤ 0.001) by

  10. The value of CT in genetic counseling in tuberous sclerosis

    International Nuclear Information System (INIS)

    Scotti, L.N.; Bartoletti, S.C.

    1980-01-01

    The families of two patients with known tuberous sclerosis were electively evaluated by computed tomography. The CT positive (and negative) examination proved to be valuable for the genetic counseling of family members without overt clinical manifestations of tuberous sclerosis. Two patients had evidence of smaller enhancing lesions (minimal demonstrable mass without hydrocephalus) following intravenous contrast enhancement. We, therefore, suggest the use of contrast enhanced scans in addition to the plain scans to identify what may represent occult neoplasms. Abdominal CT scans can prove useful in identifying the frequently associated renal hamartomas. (orig.) [de

  11. [Combined use of wide-detector and adaptive statistical iterative reconstruction-V technique in abdominal CT with low radiation dose].

    Science.gov (United States)

    Wang, H X; Lü, P J; Yue, S W; Chang, L Y; Li, Y; Zhao, H P; Li, W R; Gao, J B

    2017-12-05

    Objective: To investigate the image quality and radiation dose with wide-detector(80 mm) and adaptive statistical iterative reconstruction-V (ASIR-V) technique at abdominal contrast enhanced CT scan. Methods: In the first phantom experiment part, the percentage of ASIR-V for half dose of combined wide detector with ASIR-V technique as compared with standard-detector (40 mm) technique was determined. The human experiment was performed based on the phantom study, 160 patients underwent contrast-enhanced abdominal CT scan were prospectively collected and divided into the control group ( n =40) with image reconstruction using 40% ASIR (group A) and the study group ( n =120) with random number table. According to pre-ASIR-V percentage, the study group was assigned into three groups[40 cases in each group, group B: 0 pre-ASIR-V scan with image reconstruction of 0-100% post-ASIR-V (interval 10%, subgroups B0-B10); group C: 20% pre-ASIR-V with 20%, 40% and 60% post-ASIR-V (subgroups C1-C3); group D: 40%pre-ASIR-V with 40% and 60% post-ASIR-V (subgroups D1-D2)]. Image noise, CT attenuation values and CNR of the liver, pancreas, aorta and portal vein were compared by using two sample t test and One-way ANOVA. Qualitative visual parameters (overall image quality as graded on a 5-point scale) was compared by Mann-Whitney U test and Kruskal-Wallis H test. Results: The phantom experiment showed that the percentage of pre-ASIR-V for half dose was 40%. With the 40% pre-ASIR-V, radiation dose in the study group was reduced by 35.5% as compared with the control group. Image noise in the subgroups of B2-B10, C2-C3 and D1-D2 were lower ( t =-14.681--3.046, all P 0.05). The subjective image quality scores increased gradually in the range of 0-60% post-ASIR-V and decreased with post-ASIR-V larger than 70%. The overall image quality of subgroup B3-B8, C2-C3 and D1-D2 were higher than that in group A ( Z =-2.229--6.533, all P ASIR technique, wide-detector combined with 40% pre

  12. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  13. Role of computed tomography (CT scan in staging of cervical carcinoma

    Directory of Open Access Journals (Sweden)

    T V Prasad

    2014-01-01

    Full Text Available Background & objectives: Staging of cervical carcinoma is done clinically using International Federation of Obstetrics and Gynecology (FIGO guidelines. It is based on physical examination findings and also includes results of biopsy, endoscopy and conventional radiological tests like chest radiograph, intravenous urography and barium enema. These conventional radiological investigations have largely been replaced by computed tomography (CT and magnetic resonance imaging (MRI at present. FIGO staging system does not consider CT and MRI mandatory; however, use of these modalities are encouraged. This prospective study was conducted to determine the role of CT in staging work up in women diagnosed with cervical carcinoma. Methods: Fifty three women diagnosed with cervical carcinoma were evaluated with contrast enhanced CT scan of abdomen and pelvis. CT scan images were especially evaluated to determine tumour size, invasion of parmetrium, pelvic walls, rectum, urinary bladder and ureters, pelvic or retroperitoneal lymphadenopathy and distant metastases. CT findings were associated with clinical findings and staging, including findings from cystoscopy and sigmoidoscopy. Results: There was a poor agreement between clinical and CT staging of cervical carcinoma. Primary tumour was demonstrated on CT in 36 (70% of 53 patients. CT underestimated the parametrial, vaginal and pelvic wall invasion when compared with physical examination. CT overestimated the urinary bladder and rectal invasion when compared with cysto-sigmoidoscopy, however, CT had 100 per cent negative predictive value (NPV to exclude bladder and rectal involvement. CT detection of lymph node enlargement and lung metastases influenced the management. Interpretation & conclusions: Our findings show that CT scan does not reliably correlate with clinical FIGO staging of cervical cancer. However, it can detect urinary obstruction as well as nodal or distant metastases and thus improves the

  14. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in postmenopausal women.

    Science.gov (United States)

    Bea, J W; Blew, R M; Going, S B; Hsu, C-H; Lee, M C; Lee, V R; Caan, B J; Kwan, M L; Lohman, T G

    2016-11-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n = 103). ROIs were (1) lumbar vertebrae L2-L4 and (2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and (3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N = 25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Mean age, BMI, and total body fat were 66.1 ± 4.8 y, 25.8 ± 3.8 kg/m 2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R 2 : 0.83) and L2-IC (Adj. R 2 : 0.84) abdominal fat (%) well; the adjusted R 2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R 2 : 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat, respectively). The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in postmenopausal chronic disease risk prediction models. Am. J. Hum. Biol. 28:918-926, 2016. © 2016Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Dual energy X-ray absorptiometry spine scans to determine abdominal fat in post-menopausal women

    Science.gov (United States)

    Bea, J. W.; Blew, R. M.; Going, S. B.; Hsu, C-H; Lee, M. C.; Lee, V. R.; Caan, B.J.; Kwan, M.L.; Lohman, T. G.

    2016-01-01

    Body composition may be a better predictor of chronic disease risk than body mass index (BMI) in older populations. Objectives We sought to validate spine fat fraction (%) from dual energy X-ray absorptiometry (DXA) spine scans as a proxy for total abdominal fat. Methods Total body DXA scan abdominal fat regions of interest (ROI) that have been previously validated by magnetic resonance imaging were assessed among healthy, postmenopausal women who also had antero-posterior spine scans (n=103). ROIs were 1) lumbar vertebrae L2-L4 and 2) L2-Iliac Crest (L2-IC), manually selected by two independent raters, and 3) trunk, auto-selected by DXA software. Intra-class correlation coefficients evaluated intra and inter-rater reliability on a random subset (N=25). Linear regression models, validated by bootstrapping, assessed the relationship between spine fat fraction (%) and total abdominal fat (%) ROIs. Results Mean age, BMI and total body fat were: 66.1 ± 4.8y, 25.8 ± 3.8kg/m2 and 40.0 ± 6.6%, respectively. There were no significant differences within or between raters. Linear regression models adjusted for several participant and scan characteristics were equivalent to using only BMI and spine fat fraction. The model predicted L2-L4 (Adj. R2: 0.83) and L2-IC (Adj.R2:0.84) abdominal fat (%) well; the adjusted R2 for trunk fat (%) was 0.78. Model validation demonstrated minimal over-fitting (Adj. R2: 0.82, 0.83, and 0.77 for L2-L4, L2-IC, and trunk fat respectively). Conclusions The strong correlation between spine fat fraction and DXA abdominal fat measures make it suitable for further development in post-menopausal chronic disease risk prediction models. PMID:27416964

  16. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  17. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  18. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  19. Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

    Science.gov (United States)

    Nagayama, Yasunori; Tanoue, Shota; Tsuji, Akinori; Urata, Joji; Furusawa, Mitsuhiro; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Yoshida, Eri; Yoshida, Morikatsu; Kidoh, Masafumi; Tateishi, Machiko; Yamashita, Yasuyuki

    2018-05-01

    To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal-pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. We included 45 patients with renal dysfunction (estimated glomerular filtration rate  60 ml per lmin per 1.73 m 2 ) who underwent standard oncological abdominal-pelvic CT (600 mgI kg -1 , 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1-3 months after CT were measured. The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p 0.05). No significant kidney injury associated with CM administration was observed. 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

  20. A consideration of a measuring point of ventricular dilatation on CT scanning

    International Nuclear Information System (INIS)

    Kuno, Koichi; Miyake, Kazuo

    1980-01-01

    Ventricular dilatation has been judged by pneumo-ventricurography, pneumo-encepharography and carotid angiography (CAG), though all these procedures are very uncomfortable for patients. On the other hand, the CT scan is very easy as a follow-up study of ventricular dilatation for a weak patient. We carried out the CT scan (Hitachi CT-H 250 Scanner, NaI detector) and CAG on 84 cases. The ventricular dilatation was judged by the degree of outstretch of the strio-thalamic vein on an AP view of the phrebogram, classified into 3 types. For all three types classified by the phrebogram, we studied various measuring points of the ventricle on the CT scan. The portions measured on the CT scan were: (1) the frontal cerebro-ventricular index (F-CVI), (2) the bicaudate cerebro-ventricular index (Bicaud-CVI), and (3) the maximum Monro's cerebro-ventricular index (M-CVI), the width of the frontal horn, and the thickness of the ventricular body. The following results were obtained: (1) In measuring the ventricular size on the CT scan, the most interrelated point with the ventricular dilatation is the M-CVI - the ratio of the largest width of the body through the Monro foramen to the width of the brain. In this case, however, the width of the frontal horn and of the body should also be considered. (2) Voltage and electric current changed the EMI-number, but did not alter the measuring value. In this case, the width and the level should be kept constant. (3) The group with the marked ventricular dilatation has a larger value of the CT scan than its value of GAG. (4) The normal value of the M-CVI is 24 +- 3%, moreover, the width of the frontal horn is less than 10 mm, and the thickness of the ventricular body is less than 17 mm. (author)

  1. Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Torres, Lucas Rios; Bretas, Elisa Almeida Sathler; Bekhor, Daniel; Medeiros, Regina Bitelli; D' Ippolito, Giuseppe, E-mail: ricardo.romano@unifesp.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina; Caldana, Rogerio Pedreschi [Fleury Medicina e Saude, Sao Paulo, SP (Brazil)

    2015-09-15

    Objective: To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters. Materials and Methods: Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A - 551 studies) and three months after (group B - 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDI{sub vol} per phase, mean DLP per phase, and mean DLP per scan. Results: A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDI{sub vol} per phase, DLP per phase and DLP per scan (p < 0.001). Conclusion: The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans. (author)

  2. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  3. Intra-abdominal fat: Comparison of computed tomography fat segmentation and bioimpedance spectroscopy.

    Science.gov (United States)

    Finch, Peter

    2017-06-01

    Intra-abdominal fat is an important factor in determining the metabolic syndrome/insulin resistance, and thus the risk of diabetes and ischaemic heart disease. Computed Tomography (CT) fat segmentation represents a defined method of quantifying intra-abdominal fat, with attendant radiation risks. Bioimpedance spectroscopy may offer a method of assessment without any risks to the patients. A comparison is made of these two methods. This was a preliminary study of the utility of multifrequency bioimpedance spectroscopy of the mid abdomen as a measure of intra-abdominal fat, by comparison with fat segmentation of an abdominal CT scan in the -30 to -190 HU range. There was a significant (P abdominal fat and mid-upper arm circumference, as well as the bioimpedance parameter, the R/S ratio. Multivariate analysis showed that these were the only independant variables and allowed the derivation of a formula to estimate intra-abdominal fat: IAF = 0.02 × MAC - 0.757 × R/S + 0.036. Circumabdominal bioimpedance spectroscopy may prove a useful method of assessing intra-abdominal fat, and may be suitable for use in studies to enhance other measures of body composition, such as mid-upper arm circumference.

  4. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  5. A case of the CT scanning of a suicidal hanging brain

    International Nuclear Information System (INIS)

    Kawamata, Masaharu; Murooka, Hiroshi; Tanabe, Yasuhiko.

    1988-01-01

    A CT scanning of a case of hanging brain is reported. A 63-year-old man, who had been maintained with Aspirin (30 mg every morning) for cerebral infarction, attempted suicide by hanging, but failed. Several hours later, he was admitted because of consciousness disturbance and so was examined by means of CT scanning. Plain CT scanning showed symmetrical multiple intracerebral hemorrhages. Hemorrhages were found in the subcortical region of the bilateral temporal lobes and in the subependymal region near the foramen of Monro or in the choroidal plexus. We speculated that these hemorrhages may be caused by the congestion of the intracranial venous system caused by squeezing both internal jugular veins by hanging. Past angiograms (1981) for cerebral infarction revealed neither AVM nor angioma. (author)

  6. A review of patient dose and optimisation methods in adult and paediatric CT scanning

    International Nuclear Information System (INIS)

    Dougeni, E.; Faulkner, K.; Panayiotakis, G.

    2012-01-01

    Highlights: ► CT scanning frequency has grown with the development of new clinical applications. ► Up to 32-fold dose variation was observed for similar type of procedures. ► Scanning parameters should be optimised for patient size and clinical indication. ► Cancer risks knowledge amongst physicians of certain specialties was poor. ► A significant number of non-indicated CT scans could be eliminated. - Abstract: An increasing number of publications and international reports on computed tomography (CT) have addressed important issues on optimised imaging practice and patient dose. This is partially due to recent technological developments as well as to the striking rise in the number of CT scans being requested. CT imaging has extended its role to newer applications, such as cardiac CT, CT colonography, angiography and urology. The proportion of paediatric patients undergoing CT scans has also increased. The published scientific literature was reviewed to collect information regarding effective dose levels during the most common CT examinations in adults and paediatrics. Large dose variations were observed (up to 32-fold) with some individual sites exceeding the recommended dose reference levels, indicating a large potential to reduce dose. Current estimates on radiation-related cancer risks are alarming. CT doses account for about 70% of collective dose in the UK and are amongst the highest in diagnostic radiology, however the majority of physicians underestimate the risk, demonstrating a decreased level of awareness. Exposure parameters are not always adjusted appropriately to the clinical question or to patient size, especially for children. Dose reduction techniques, such as tube-current modulation, low-tube voltage protocols, prospective echocardiography-triggered coronary angiography and iterative reconstruction algorithms can substantially decrease doses. An overview of optimisation studies is provided. The justification principle is discussed along

  7. CT scans of giant aneurysms in the vertebro-basilar artery

    International Nuclear Information System (INIS)

    Shishido, Toyofumi; Ohsugi, Tamotsu; Motozaki, Takahiko; Sakaki, Saburo; Matsuoka, Kenzo

    1980-01-01

    Clinical course and neurological and neuroradiological findings of giant aneurysms in the vertebro-basilar artery observed in two of our cases were discussed. The first case was a 66-year-old man. He complained of sensory disturbance over his left face and unstable gait for 2 years before admission. Neurological examinations on admission showed hypesthesia in the territory of the second branch of the left fifth cranial nerve, nystagmus, and a left cerebellar sign. No mental deterioration or pyramidal signs were noticed. Retrograde left brachial artery angiograms revealed a giant aneurysm with inferior pointing measuring 30 x 10 mm in diameter arising from the left superior cerebellar artery. Precontrast CT scans demonstrated a round, large, high-density area, cantaining a relatively low-density area within it, in the medioventral portion of the left cerebellum; a part of this high-density area was markedly enhanced in the postcontrast CT scan. No ventricular dilatations were noticed by CT scans. Direct surgery was abandoned due to the size and location of the aneurysm. No neurologically abnormal finding developed after discharge. The second case was a 61-year-old man. He complained of unstable gait for 2 years before admission. Neurological examinations on admission showed bilateral pyramidal sings (more pronounced on the left) and nystagmus. There were no cranial nerve palsy and no sensory disturbances. Precontrast CT scans showed a large, oval, high-density area in the medioventral portion of the right cerebellum, extending to the upper brainstem; a part of this high-density area was markedly enhanced in the postcontrast CT scans. Retrograde left brachial artery angiograms revealed that the fusiform aneurysm in the left vertebral, the basilar artery, and the dilated basilar artery ran 30 mm from the clivus, with a dorsal convex arch. (J.P.N.)

  8. Perforated appendicitis: accuracy of CT diagnosis and correlation of CT findings with the length of hospital

    International Nuclear Information System (INIS)

    Siddiqui, H.A.; Afzal, S.

    2007-01-01

    To determine the sensitivity and specificity of CT findings in the differentiation of perforated from nonperforated appendicitis and correlate CT diagnosis with the length of hospital stay. The study included 70 patients who presented with right lower quadrant abdominal pain and underwent preoperative CT scan followed by appendectomy. Patients were divided into two groups of having perforated and nonperforated appendicitis on the basis of CT scan findings. The surgical and pathological reports combined were considered the reference standard for the diagnosis of perforated appendicitis. Various CT scan findings and average duration of hospital stay in days was compared by t-test. Twenty-six (37%) of 70 patients had perforated appendicitis. It was correctly identified on pre-operative CT scan in 18 patients. There were 18 true positive diagnoses, 43 true negative diagnoses, 1 false positive diagnosis and 8 false negative diagnoses which yielded a sensitivity of 69%, specificity of 97%, positive predictive value of 94% and negative predictive value of 84%. Mean length of hospital stay in perforated group was 6.3 days and 2.9 days in nonperforated group. Severe periappendiceal inflammation, periappendiceal and or abdominopelvic fluid and abscess were significantly associated with perforated appendicitis and with a significant longer hospital stay (p <.001). CT scan is 69% sensitive and 97% specific for the diagnosis of perforated appendicitis and constellation of CT findings can be used to select patients with perforated appendicitis for initial non-operative management. Presence of CT signs of significant appendiceal inflammation is independent predictor of longer hospital stay. (author)

  9. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takeguchi, Takaya (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan); Tokyo Medical and Dental University, Department of Diagnostic Radiology, Tokyo (Japan)); Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan)), Email: kj-ibkr@qd6.so-net.ne.jp

    2012-02-15

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm +- 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm +- 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  10. X-CT imaging method for large objects using double offset scan mode

    International Nuclear Information System (INIS)

    Fu Jian; Lu Hongnian; Li Bing; Zhang Lei; Sun Jingjing

    2007-01-01

    In X-ray computed tomography (X-CT) inspection, rotate-only scanner is commonly used because this configuration offers the highest imaging speed and best utilization of X-ray dose. But it requires that the imaging region of the scanned object must fit within the X-ray beam. Another configuration, transverse-rotate scanner, has a bigger field of view, but it is much more time consuming. In this paper, a two-dimensional X-CT imaging method for large objects is proposed to overcome the existing disadvantages. The scan principle of this method has been described and the reconstruction algorithm has been deduced. The results of the computer simulation and the experiments show the validity of the new method. Analysis shows that the scan field of view of this method is 1.8 times larger than that of rotate-only X-CT. The scan speed of this method is also much quicker than transverse-rotate X-CT

  11. Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre; Becker, Minerva; Becker, Christoph D.; Zaidi, Habib; Platon, Alexandra [University Hospital of Geneva, Department of Radiology, Geneva (Switzerland); Halfon Poletti, Alice; Rutschmann, Olivier T. [University Hospital of Geneva, Department of Community, Primary Care and Emergency Medicine, Geneva (Switzerland); Perneger, Thomas [University Hospital of Geneva, Division of Clinical Epidemiology, Geneva (Switzerland)

    2017-08-15

    To determine if radiation dose delivered by contrast-enhanced CT (CECT) for acute abdominal pain can be reduced to the dose administered in abdominal radiography (<2.5 mSv) using low-dose CT (LDCT) with iterative reconstruction algorithms. One hundred and fifty-one consecutive patients requiring CECT for acute abdominal pain were included, and their body mass index (BMI) was calculated. CECT was immediately followed by LDCT. LDCT series was processed using 1) 40% iterative reconstruction algorithm blended with filtered back projection (LDCT-IR-FBP) and 2) model-based iterative reconstruction algorithm (LDCT-MBIR). LDCT-IR-FBP and LDCT-MBIR images were reviewed independently by two board-certified radiologists (Raters 1 and 2). Abdominal pathology was revealed on CECT in 120 (79%) patients. In those with BMI <30, accuracies for correct diagnosis by Rater 1 with LDCT-IR-FBP and LDCT-MBIR, when compared to CECT, were 95.4% (104/109) and 99% (108/109), respectively, and 92.7% (101/109) and 100% (109/109) for Rater 2. In patients with BMI ≥30, accuracies with LDCT-IR-FBP and LDCT-MBIR were 88.1% (37/42) and 90.5% (38/42) for Rater 1 and 78.6% (33/42) and 92.9% (39/42) for Rater 2. The radiation dose delivered by CT to non-obese patients with acute abdominal pain can be safely reduced to levels close to standard radiography using LDCT-MBIR. (orig.)

  12. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  13. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  14. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  15. Focused abdominal sonography for trauma in the clinical evaluation of children with blunt abdominal trauma.

    Science.gov (United States)

    Ben-Ishay, Offir; Daoud, Mai; Peled, Zvi; Brauner, Eran; Bahouth, Hany; Kluger, Yoram

    2015-01-01

    In pediatric care, the role of focused abdominal sonography in trauma (FAST) remains ill defined. The objective of this study was to assess the sensitivity and specificity of FAST for detecting free peritoneal fluid in children. The trauma registry of a single level I pediatric trauma center was queried for the results of FAST examination of consecutive pediatric (blunt trauma patients over a period of 36 months, from January 2010 to December 2012. Demographics, type of injuries, FAST results, computerized tomography (CT) results, and operative findings were reviewed. During the study period, 543 injured pediatric patients (mean age 8.2 ± 5 years) underwent FAST examinations. In 95 (17.5 %) FAST was positive for free peritoneal fluid. CT examination was performed in 219 (40.3 %) children. Positive FAST examination was confirmed by CT scan in 61/73 (83.6 %). CT detected intra-peritoneal fluid in 62/448 (13.8 %) of the patients with negative FAST results. These findings correspond to a sensitivity of 50 %, specificity of 88 %, positive predictive value (PPV) of 84 %, and a negative predictive value (NPV) of 58 %. In patients who had negative FAST results and no CT examination (302), no missed abdominal injury was detected on clinical ground. FAST examination in the young age group (tool to discriminate injured children in need of further imaging evaluation.

  16. Whole-body MSCT of patients after polytrauma: abdominal injuries; Ganzkoerper-MSCT beim Polytrauma: Abdominelle Verletzungen

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, B.; Sadick, M.; Diehl, S.; Dueber, C. [Universitaetsklinikum Mannheim, Inst. fuer Klinische Radiologie (Germany); Obertacke, U. [Universitaetsklinikum Mannheim, Zentrum fuer Orthopaedie und Traumatologie (Germany)

    2005-12-15

    Purpose: The goal of this retrospective study was to evaluate the spectrum of abdominal injuries and the reliability of computed tomography-based diagnosis in patients after polytrauma. Material and methods: CT findings and clinical reports for 177 patients after polytrauma were evaluated with regard to abdominal injuries. Clinical patient reports at the time of discharge from the hospital were utilized as the standard of reference. Abdominal injuries resulting from an accident, frequent additional traumas and following therapeutic procedures were recorded. In the case of discrepancies in the reports, the CT scans were viewed retrospectively. Results: In 30 out of 177 patients, 42 abdominal injuries were detected. 69% of the injuries were caused by traffic accidents while 31% resulted from falls. Liver and spleen injuries were the most common. 50% of the cases were treated surgically, and the other half of the cases underwent non-surgical conservative therapy. Massive chest traumas, pelvic injuries, cerebral traumas and injuries to extremities were commonly associated with abdominal injuries. Evaluation of the discrepancies in the clinical reports showed that injury to the pancreas and the small intestine were not successfully detected on CT, thus resulting in a false negative diagnosis. Early stages of organ parenchyma laceration were also initially misdiagnosed on CT. (orig.)

  17. Imaging of abdominal tumours: CT or MRI?

    International Nuclear Information System (INIS)

    Olsen, Oeystein E.

    2009-01-01

    The scope of this review is to discuss a theoretical approach to imaging policy, particularly in the perspective of radiation risk reduction. Decisions are ideally driven by empirical evidence about efficacy and risk, e.g., in classical hierarchical efficacy model. As a result of the paucity of empirical evidence (inevitable because of rapid technological development), a pragmatic model is needed. This should avoid overemphasis of factors that currently seem to hamper change, namely personal preference, local expertise, infrastructure, availability. Extrapolation of current general knowledge about CT and MRI demonstrates how a pragmatic approach can be applied in the real world with intermediate goals such as (1) channeling patients from CT to MRI, and (2) reducing CT-delivered radiation. Increased utilisation of MRI in body imaging requires optimisation of scan protocols and equipment, and, being a very operator-dependent modality, the active involvement of the radiologist. In CT dose reduction the main challenge is to benchmark the minimum radiation-dose requirement, and therefore the minimum required image quality that is diagnostically acceptable. As this will ultimately depend on pre-test likelihoods in institutional populations, it is difficult to issue general guidance, and local assessment remains a cornerstone in this effort. (orig.)

  18. Progression of CT scan findings in Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hisaharu; Hirayama, Yoshito; Sakuragawa, Norio; Arima, Masataka (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan))

    1989-07-01

    Progression of the lesions revealed by CT scan was observed in five girls with Rett syndrome. The most distinct and common finding was progressive dilatation of Sylvian fissures, frontal extracerebral space, interhemispheric fissure, and sulci mainly in frontal lobe. It may indicate progressive lesion in the frontal and the temporal lobes. In addition, dilatation of the anterior horns of the lateral ventricles and the third ventricle was noted in some cases. Brainstem and cerebellum were small at any age with some morphological development as the patients became elder. Neither malformations nor abnormalities in density were found in any case. It is concluded that the main lesion of Rett syndrome on CT scan is progressive and localized in the frontal and the temporal lobes. (author).

  19. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  20. Cushing's syndrome with an apparently normal CT scan

    International Nuclear Information System (INIS)

    Vlahos, L.; Strigaris, K.; Aliferopoulos, D.; Pontifex, G.

    1981-01-01

    A case of Cushing's syndrome is described in which the CT scan was considered as normal. The diagnosis was established with selective venography and blood sampling and was verified surgically. (orig.)

  1. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  2. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  3. Computerized abdominal tomography in Wilson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchikura, Keiko; Ogawa, Teruyuki; Nakajima, Akihisa; Ono, Yasuhiko

    1986-05-01

    Cranial and abdominal computerized tomography (CT) was performed in a 10-year-old boy with Wilson's disease complicated by liver cirrhosis. Abdominal CT showed diffuse high density areas over the whole part of the liver propably due to copper sediments, although there was no abnormal cranial CT findings. Decreased high density area of the liver was seen 60 days after the administration of D-penicillamine, suggesting the excretion of copper from the liver. Abdominal CT, as well as cranial CT, may be of help to diagnose Wilson's disease and evaluate therapeutic effects. (Namekawa, K.).

  4. The diagnostic value of PET/CT scanning in patients with cervical cancer

    DEFF Research Database (Denmark)

    Loft, Annika; Berthelsen, Anne Kiil; Roed, Henrik

    2007-01-01

    OBJECTIVE: To investigate the clinical value of PET/CT as a supplement to FIGO staging in patients with cervical cancer stage >or=1B. METHODS: This prospective study included 120 consecutive patients. After staging, a whole-body PET/CT scan was performed and these examinations were divided into two....../CT scanning for newly diagnosed cervical cancer FIGO stage >or=1B has a high sensitivity and specificity, and can be a valuable supplement to the FIGO staging procedure....

  5. CT manifestations of ileal dysgenesis

    Energy Technology Data Exchange (ETDEWEB)

    Oberhelman, Amy P.; Herman, Thomas E.; McAlister, William H. [St. Louis Children' s Hospital, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Department of Radiology, St. Louis, MO (United States); Keating, James P. [St. Louis Children' s Hospital, Mallinckrodt Department of Pediatrics, Washington University School of Medicine, Division of Gastroenterology, St. Louis, MO (United States); Rollins, Michael D.; Dillon, Patrick A. [St. Louis Children' s Hospital, Department of Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2007-02-15

    Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

  6. CT manifestations of ileal dysgenesis

    International Nuclear Information System (INIS)

    Oberhelman, Amy P.; Herman, Thomas E.; McAlister, William H.; Keating, James P.; Rollins, Michael D.; Dillon, Patrick A.

    2007-01-01

    Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

  7. Abdominal multi-organ CT segmentation using organ correlation graph and prediction-based shape and location priors.

    Science.gov (United States)

    Okada, Toshiyuki; Linguraru, Marius George; Hori, Masatoshi; Summers, Ronald M; Tomiyama, Noriyuki; Sato, Yoshinobu

    2013-01-01

    The paper addresses the automated segmentation of multiple organs in upper abdominal CT data. We propose a framework of multi-organ segmentation which is adaptable to any imaging conditions without using intensity information in manually traced training data. The features of the framework are as follows: (1) the organ correlation graph (OCG) is introduced, which encodes the spatial correlations among organs inherent in human anatomy; (2) the patient-specific organ shape and location priors obtained using OCG enable the estimation of intensity priors from only target data and optionally a number of untraced CT data of the same imaging condition as the target data. The proposed methods were evaluated through segmentation of eight abdominal organs (liver, spleen, left and right kidney, pancreas, gallbladder, aorta, and inferior vena cava) from 86 CT data obtained by four imaging conditions at two hospitals. The performance was comparable to the state-of-the-art method using intensity priors constructed from manually traced data.

  8. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi [Kobe Central Municipal Hospital, Kobe (Japan)

    1983-04-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.''

  9. Analysis the findings of chest radiograph and CT scan in 217 acute thoracic trauma

    International Nuclear Information System (INIS)

    Huang Shaoying

    2005-01-01

    Objective: To evaluate chest radiograph and CT scan in assessing acute thoracic trauma. Methods: Retrospectively analyzed the findings of chest radiograph and CT scan in 217 cases of acute thoracic trauma and positive rate of each modality was compared. Results: The positive rate of rib and clavicle fracture was higher in chest radiograph than these in CT scan. But the positive rate of chest wall hematoma, mediastinum and subcutaneous emphysema, pneumothorax, hydropneumothorax, damage of lung parenchyma and traumatic pulmonary atelectasis was higher in CT scan than those in chest radiograph. Conclusion: The application of the combined imaging modalities improves assessing of acute thoracic trauma, because the imaging manifestation of the lesion is various. (authors)

  10. Effects of abdominal fat distribution parameters on severity of acute pancreatitis.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2012-07-01

    Obesity is a well-established risk factor for acute pancreatitis. Increased visceral fat has been shown to exacerbate the pro-inflammatory milieu experienced by patients. This study aimed to investigate the relationship between the severity of acute pancreatitis and abdominal fat distribution parameters measured on computed tomography (CT) scan.

  11. Is dual-phase abdominal CT necessary for the optimal detection of metastases from renal cell carcinoma?

    International Nuclear Information System (INIS)

    Jain, Y.; Liew, S.; Taylor, M.B.; Bonington, S.C.

    2011-01-01

    Aim: To determine whether dual-phase abdominal computed tomography (CT) detected more metastases than portal-phase CT alone in patients with renal cell carcinoma (RCC). Materials and methods: Audit committee approval was obtained. A retrospective audit was undertaken in 100 patients who underwent both arterial and portal phase CT. The CT images were independently reviewed by two consultant radiologists. The presence of metastases in the liver, pancreas, and contralateral kidney were recorded for each phase of contrast enhancement. Results: Metastases were identified in the liver in 27 patients, pancreas in 12, and contralateral kidney in 23 patients. Nine of the 27 (33%) liver metastases, three of the 12 (25%) pancreatic metastases, and two of the 23 (9%) renal metastases were only detected in the arterial phase, whilst four of the 27 (15%) liver metastases, three of the 12 (25%) pancreatic metastases, and two of the 23 (9%) renal metastases were only detected in the portal phase. Nine patients (9%) had metastases only visualized in the arterial phase, and six (6%) only in the portal phase. Detection of metastases only visible in the arterial phase led to a change of management in two patients (2%). Conclusion: The audit results support our current standard of dual-phase abdominal CT for optimal detection of RCC metastases.

  12. Ultrafast CT scanning of an oak log for internal defects

    Science.gov (United States)

    Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder

    1989-01-01

    Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...

  13. [Non-operation management of 12 cases with brain abscess demonstrated by CT scan].

    Science.gov (United States)

    Long, J

    1990-12-01

    This paper reported 12 cases with brain abscess demonstrated by CT scan. Using antibiotic management without surgical intervention, in 10 cases the curative effects were satisfactory. The paper indicated that CT scan was very useful in prompt and correct diagnosis of brain abscess and with sequential CT scan medical therapy was feasible. It is significant in treatment of brain abscess especially for the patients who have a poor general condition, have the brain abscess located in important functional area or have multiple abscesses so that the operation is difficult for them.

  14. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  15. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  16. Analysis of cranial CT-scan findings in cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, F.; Andoh, T.; Une, K.; Takamatsu, T. (Kitakyushu Municipal Sogo-Ryoiku Center (Japan))

    1981-06-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed.

  17. Analysis of cranial CT-scan findings in cerebral palsy

    International Nuclear Information System (INIS)

    Wada, Fumio; Andoh, Tadashi; Une, Koji; Takamatsu, Tsurukichi

    1981-01-01

    CT-scan findings of 87 cerebral palsied children were studied. They consist of 23 cases of spastic quadriplegia, 9 cases of diplegia, 12 cases of paraplegia, 24 cases of athetosis and mixed type, and 19 cases of hemiplegia. In the former four types, ventricular dilatation and cortical atrophy were measured and abnormal changes in cerebral substance and cerebellar atrophy were observed. Spastic quadriplegia showed most intense changes in every aspect of the abnormalities, while paraplegia had almost normal appearance. Athetosis and mixed type had moderate changes. Hemiplegia always showed asymmetrical view on CT-scan, dilatation of lateral ventricle or atrophy of hemisphere in contralateral side being observed. (author)

  18. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  19. Study on the brain CT scan of SLE patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, S; Narita, M; Katoh, K; Matsunaga, K; Ishigatsubo, Y [Yokohama City Univ. (Japan). Faculty of Medicine

    1982-03-01

    Cranial CT scanning revealed abnormality in 12 of 25 patients with SLE (48%). Ventricular sulcal enlargement was found mostly in younger patients between 16 and 36 years, an average of 25 years. Abnormality in electroencephalogram, principally paroxysmal abnormality, was found in 8 of 13 cases (62%) of normal CT findings. Non-paroxysmal slow-wave abnormality was observed in 9 of 12 abnormal CT cases. Of 13 patients with CNS symptoms, 8 had abnormal CT findings, and 5 had only mental disorder with normal CT findings. In 12 patients without neuropsychiatric involvement, 4 (33%) had abnormal CT findings. The rate of abnormal CT findings was increased in the patients receiving a high dosage of a steroid agent. Five of 6 patients who showed ventricular sulcal enlargement had been given prednisolone in a dosage of 35 mg or more per day.

  20. Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake, E-mail: yamada@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Jinzaki, Masahiro, E-mail: jinzaki@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Hosokawa, Takahiro, E-mail: snowglobe@infoseek.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Tanami, Yutaka, E-mail: tanami@rad.med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Abe, Takayuki, E-mail: tabe@z5.keio.jp [Center for Clinical Research, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan); Kuribayashi, Sachio, E-mail: skuribay@med.keio.ac.jp [Department of Diagnostic Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582 (Japan)

    2014-10-15

    Highlights: • We compared virtual monochromatic spectral (VMS) images with 120-kVp images. • VMS images are generated using accurate two-material beam-hardening correction. • Abdominal 70-keV VMS images provide better image quality than 120-kVp images. • Iterative reconstruction can further improve the image quality of VMS images. - Abstract: Objectives: To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. Materials and methods: Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. Results: VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P < 0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P < 0.004). Conclusions: VMS

  1. Abdominal CT: An intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hosokawa, Takahiro; Tanami, Yutaka; Abe, Takayuki; Kuribayashi, Sachio

    2014-01-01

    Highlights: • We compared virtual monochromatic spectral (VMS) images with 120-kVp images. • VMS images are generated using accurate two-material beam-hardening correction. • Abdominal 70-keV VMS images provide better image quality than 120-kVp images. • Iterative reconstruction can further improve the image quality of VMS images. - Abstract: Objectives: To compare quantitative and subjective image quality between virtual monochromatic spectral (VMS) and conventional polychromatic 120-kVp imaging performed during the same abdominal computed tomography (CT) examination. Materials and methods: Our institutional review board approved this prospective study; each participant provided written informed consent. 51 patients underwent sequential fast kVp-switching dual-energy (80/140 kVp, volume CT dose index: 12.7 mGy) and single-energy (120-kVp, 12.7 mGy) abdominal enhanced CT over an 8 cm scan length with a random acquisition order and a 4.3-s interval. VMS images with filtered back projection (VMS-FBP) and adaptive statistical iterative reconstruction (so-called hybrid IR) (VMS-ASIR) (at 70 keV), as well as 120-kVp images with FBP (120-kVp-FBP) and ASIR (120-kVp-ASIR), were generated from dual-energy and single-energy CT data, respectively. The objective image noises, signal-to-noise ratios and contrast-to-noise ratios of the liver, kidney, pancreas, spleen, portal vein and aorta, and the lesion-to-liver and lesion-to-kidney contrast-to-noise ratios were measured. Two radiologists independently and blindly assessed the subjective image quality. The results were analyzed using the paired t-test, Wilcoxon signed rank sum test and mixed-effects model with Bonferroni correction. Results: VMS-ASIR images were superior to 120-kVp-FBP, 120-kVp-ASIR and VMS-FBP images for all the quantitative assessments and the subjective overall image quality (all P < 0.001), while VMS-FBP images were superior to 120-kVp-FBP and 120-kVp-ASIR images (all P < 0.004). Conclusions: VMS

  2. Significance and problems of the dynamic CT scan for the diagnosis and treatment of cerebral infarctions

    International Nuclear Information System (INIS)

    Morita, Akio; Teraoka, Akira

    1985-01-01

    Dynamic CT scan is a very useful method for the diagnosis of cerebral infarctions and other ischemic disorders. We have used this method for 1) the ultra-early stage diagnosis of major infarctions, 2) the detection of the recanalization and the disruption of the blood-brain barrier, and 3) the detection of latent ischemic lesions. In this report we discussed the clinical cases and the usual use of this dynamic CT scan. We used a GE CT/T8800 scanner for dynamic CT scanning. Manual bolus-contrast-medium injection was done simultaneously with the first scanning, and 6 sequential scannings (scan time: 4.8 s; scan interval: 1.4 s) were done on the same slice level. Especially in major infarctions (e.g., MCA occlusion), OM 40 was the most preferred slice. In cases of ultra-early stage infarctions (i.e., no abnormal lesions in non-enhanced CT), we used this dynamic CT scan immediately after the non-enhanced CT; we could thus obtain information on the ischemic lesions and the ischemic degree. After that we repeated this examination on Days 3, 7, and 14 for the evaluation of the recanalization and blood-brain-barrier disruption. In the cases of TIA and impending or progressing strokes, dynamic CT scan could disclose latent ischemic lesions; in there instances, we treated the patients with intensive to prevent the prognosis from worsening. These benefits and also some problems were discussed. (author)

  3. Utility of CT scan for the diagnosis of chest wall tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, A.; Le Breton, C.; Tassart, M.; Korzec, J.; Bigot, J.M.; Carette, M.F. [Department of Radiology, Tenon Hospital, Paris (France)

    1999-10-01

    The objective of this study was to determine the utility of CT scan findings for the diagnosis of chest wall tuberculosis, excluding the spine. We reviewed 15 patients (13 Africans and 2 Indians) with chest wall tuberculosis, retrospectively. The radiologic examination consisted of a plain X-ray and a CT scan of the chest for each patient. The site of disease was the rib in 13 patients or the body of the sternum in 2 patients. One rib was involved in 11 patients, 2 contiguous ribs (one site) in 2 patients, and bilateral disease (two sites) was observed in the remaining patient. The 14 rib sites involved the posterior arc or costovertebral joint in 11 cases, the anterior arc in 2 cases, and the anterior and middle arc in 1 case. The CT scan findings were an abscess (n = 14) or a soft tissue mass (n = 2), osteolytic lesions (n = 13), periosteal reaction (n = 10), and sequestrum (n = 14). Bone sclerosis was observed only in 3 cases of rib involvement. The association of a soft tissue abscess, an osteolytic lesion, and sequestrum, especially in immigrants to France, suggests chest wall tuberculosis on CT scan. (orig.) With 5 figs., 2 tabs., 11 refs.

  4. CT scanning in stroke patients: meeting the challenge in the remote and rural district general hospital.

    Science.gov (United States)

    Todd, A W; Anderson, E M

    2009-05-01

    National audit data allow crude comparison between centres and indicate that most Scottish hospitals fail to meet current guidelines for CT scanning of the brain in stroke patients. This study identifies some of the reasons for delay in performing CT scans in a largely rural population. This audit study assesses the delays from onset of symptoms, time of admission and request received to CT scan in stroke patients for three different in-patient groups as well as those managed in the community. The reasons for delay in CT scanning varied between different patient groups but for one group of in-patients, changes in booking procedure and introduction of a second CT scanner increased the proportion scanned within 48 hours of request from 65% to 96%. Further developments including the introduction of Saturday and Sunday routine CT scanning, radiologist reporting from home and additional CT scanners placed in remote hospitals may be expected to improve these figures further. Target times of three hours from onset of symptoms to scan to allow thrombolysis may however be impossible to meet for all stroke patients in rural areas.

  5. CT findings in children with Meckel diverticulum

    International Nuclear Information System (INIS)

    Olson, Doug E.; Donnelly, Lane F.; Kim, Yong-Woo

    2009-01-01

    Approximately 0.04% of the general population will present with a complication related to Meckel diverticulum. The classic teaching is that symptomatic children with Meckel diverticulum present with painless rectal bleeding and are evaluated with a radionuclide scan. Our subjective experience is that we see children with Meckel diverticulum who present with abdominal pain and are evaluated by CT. We reviewed the findings on CT in children with pathologically proven Meckel diverticulum to identify characteristic patterns of presentation. Databases were searched (2004-2008) for all children who had a pathologic diagnosis of Meckel diverticulum and a CT scan performed prior to surgery. Demographics, pathology, and CT features were reviewed. CT features reviewed included: soft-tissue stranding, abnormal calcifications, bowel obstruction, free air, free peritoneal fluid, cystic mass, intussusception, obvious lead point, location, and whether a normal appendix was identified. The frequency of Meckel diverticulum encountered on CT scans was compared to that found during the same period of time on technetium pertechnetate studies. The review identified 16 subjects (mean age 9.5 years, M:F 9:7). CT findings included: soft-tissue stranding in nine (56%), small-bowel obstruction (SBO) in nine (56%), intussusception in three (19%), free fluid in ten (63%), cystic mass in four (25%), calcification in none (0%), free air in one (6%), and no abnormalities in two (13%). A normal appendix was identified in only five children (31%). There were three basic patterns of presentation of abnormalities: SBO only in five, intussusception with SBO in three, or cystic mass with inflammatory stranding in four (one with SBO). Also, 2.3 times more Meckel diverticulum was encountered on CT than on technetium pertechnetate studies. Meckel diverticulum is currently more commonly encountered in children on CT performed for abdominal pain than on technetium pertechnetate studies. There are three

  6. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi (Kobe Central Municipal Hospital, Kobe (Japan))

    1983-04-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.''

  7. Serial CT scans of cerebral hypoxia due to prolonged status epilepticus

    International Nuclear Information System (INIS)

    Saiwai, Shigeo; Matsumura, Yasumasa; Tamaoka, Koichi; Fukuda, Teruo; Miyamoto, Takeshi

    1983-01-01

    Serial computed tomography (CT) scans of 5 infants with status epilepticus were reviewed. Four out of the 5 infants fortunately had CT scans before status epilepticus because of a convulsion. There was a diffuse and mild low density in the hemisphere, with small ventricles and tight sulci (brain swelling) at 1 to 2 days after ictus. Thereafter, a diffuse low density became apparent except for the cerebellum, the brain stem, the thalamus, and the basal ganglia. Two to 4 weeks after ictus, a localized, mottled low density was demonstrated on the cerebral mantle and atrophic changes became progressively clear. In 3 cases, no abnormal enhancement was elicited on contrast CT scans performed between 5 to 16 days after status epilepticus. We discussed the possible pathophysiological aspects of the brain damage due to ''prolonged status epilepticus.'' (author)

  8. Focal hepatic steatosis: ultrasound and CT scan features may mimick carcinoma of the liver

    International Nuclear Information System (INIS)

    Monnin, J.L.; Blanc, F.; Guiry, P.; Bruel, J.M.; Monnin, E.; Ciurana, A.J.

    1988-01-01

    Ultrasound and CT scan features of focal hepatic steatosis (FHS) may closely resemble those of primary or secondary malignant hepatic tumors. Three cases of FHS in chronic alcoholics are reported. In two cases, the area of steatosis was hyperechogenic upon ultrasonography. In all three patients, CT scan demonstrated a hypodense image, with poor enhancement following opacification and no mass effect. Diagnosis of FHS was ascertained upon hepatic biopsy under CT scan guidance in all three patients [fr

  9. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration.

    Science.gov (United States)

    Wolthaus, J W H; Sonke, J J; van Herk, M; Damen, E M F

    2008-09-01

    lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods noise of individual 4D CT scan frames. We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a

  10. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    International Nuclear Information System (INIS)

    Takeguchi, Takaya; Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko

    2012-01-01

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm ± 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm ± 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  11. Traumatic injuries: imaging of abdominal and pelvic injuries

    International Nuclear Information System (INIS)

    Weishaupt, Dominik; Grozaj, Ana M.; Willmann, Juergen K.; Roos, Justus E.; Hilfiker, Paul R.; Marincek, Borut

    2002-01-01

    The availability of new imaging modalities has altered the diagnostic approach to patients with abdominal and pelvic trauma. Computed tomography and ultrasound have largely replaced diagnostic peritoneal lavage. Ultrasound is used in most trauma centers as the initial imaging technique for the detection of hemoperitoneum and helps to determine the need for emergency laparotomy. Computed tomography allows for an accurate diagnosis of a wide range of traumatic abdominal and pelvic conditions. The speed of single-detector helical and multi-detector row CT (MDCT) permits a rapid CT examination of the seriously ill patient in the emergency room. In particular, the technology of MDCT permits multiple, sequential CT scans to be quickly obtained in the same patient, which is a great advance in the rapid assessment of the multiple-injured patient. The evolving concepts in trauma care promoting non-operative management of liver and splenic injuries creates the need for follow-up cross-sectional imaging studies in these patients. Computed tomography and, less frequently, MR or ultrasound, are used for this purpose. (orig.)

  12. Traumatic injuries: imaging of abdominal and pelvic injuries

    Energy Technology Data Exchange (ETDEWEB)

    Weishaupt, Dominik; Grozaj, Ana M.; Willmann, Juergen K.; Roos, Justus E.; Hilfiker, Paul R.; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-06-01

    The availability of new imaging modalities has altered the diagnostic approach to patients with abdominal and pelvic trauma. Computed tomography and ultrasound have largely replaced diagnostic peritoneal lavage. Ultrasound is used in most trauma centers as the initial imaging technique for the detection of hemoperitoneum and helps to determine the need for emergency laparotomy. Computed tomography allows for an accurate diagnosis of a wide range of traumatic abdominal and pelvic conditions. The speed of single-detector helical and multi-detector row CT (MDCT) permits a rapid CT examination of the seriously ill patient in the emergency room. In particular, the technology of MDCT permits multiple, sequential CT scans to be quickly obtained in the same patient, which is a great advance in the rapid assessment of the multiple-injured patient. The evolving concepts in trauma care promoting non-operative management of liver and splenic injuries creates the need for follow-up cross-sectional imaging studies in these patients. Computed tomography and, less frequently, MR or ultrasound, are used for this purpose. (orig.)

  13. Computed tomography findings of early abdominal postoperative complications

    International Nuclear Information System (INIS)

    Zissin, R.; Osadchy, A.; Gayer, G.

    2007-01-01

    Various surgical approaches are used for different abdominal pathological conditions. Postoperative complications occur not infrequently and vary according to the type of the surgery and the clinical context. Nowadays, multidetector computed tomography (MDCT) provides superb anatomic detail and diagnostic accuracy for various intraabdominal pathological processes, even if clinically unsuspected, and it thus has become an essential diagnostic tool for evaluating postoperative insults. Other advantages of abdominal MDCT include its accessibility and its speed, which allow scanning of uncooperative, marginally stable patients. Computed tomography (CT)-guided percutaneous (PC) drainage of postoperative collections is another advantage of CT. Therefore, although CT requires transportation of a critically ill, postoperative patient, it is recommended in any suspicious clinical setting because several conditions require prompt management and a correct diagnosis is crucial. In assessing a patient for suspected postoperative complications, several points should be taken into consideration, including the relevant clinical and laboratory data, the surgical findings, the type of the surgery, the time elapsed since surgery, and the operative technique (either open laparotomy of laparoscopic procedure). (author)

  14. An automatic virtual patient reconstruction from CT-scans for hepatic surgical planning.

    Science.gov (United States)

    Soler, L; Delingette, H; Malandain, G; Ayache, N; Koehl, C; Clément, J M; Dourthe, O; Marescaux, J

    2000-01-01

    PROBLEM/BACKGROUND: In order to help hepatic surgical planning we perfected automatic 3D reconstruction of patients from conventional CT-scan, and interactive visualization and virtual resection tools. From a conventional abdominal CT-scan, we have developed several methods allowing the automatic 3D reconstruction of skin, bones, kidneys, lung, liver, hepatic lesions, and vessels. These methods are based on deformable modeling or thresholding algorithms followed by the application of mathematical morphological operators. From these anatomical and pathological models, we have developed a new framework for translating anatomical knowledge into geometrical and topological constraints. More precisely, our approach allows to automatically delineate the hepatic and portal veins but also to label the portal vein and finally to build an anatomical segmentation of the liver based on Couinaud definition which is currently used by surgeons all over the world. Finally, we have developed a user friendly interface for the 3D visualization of anatomical and pathological structures, the accurate evaluation of volumes and distances and for the virtual hepatic resection along a user-defined cutting plane. A validation study on a 30 patients database gives 2 mm of precision for liver delineation and less than 1 mm for all other anatomical and pathological structures delineation. An in vivo validation performed during surgery also showed that anatomical segmentation is more precise than the delineation performed by a surgeon based on external landmarks. This surgery planning system has been routinely used by our medical partner, and this has resulted in an improvement of the planning and performance of hepatic surgery procedures. We have developed new tools for hepatic surgical planning allowing a better surgery through an automatic delineation and visualization of anatomical and pathological structures. These tools represent a first step towards the development of an augmented

  15. Quantitative measurement of ventricular dilatation on CT scan

    International Nuclear Information System (INIS)

    Okita, Naoshi; Mochizuki, Hiroshi; Takase, Sadao

    1985-01-01

    Cerebral atrophy might be judged from the ventricular dilatation with some indices, calculated from various ventricular width. But, there is no general agreement on what index is the most reliable. In this paper, we attempted to establish the index, easy to measure and most reliable. Our method is as follow. 1) We carried out the CT scan (EMI 1010) on 89 neurologically intact patients. Scans were parallel to orbito-meatal line (OML), and were 10 mm in thickness. On CT scan films, various width, area of anterior horns and area of bodies of lateral ventricles were measured. Measurement about the anterior horns of lateral ventricles were carried out on image the most clearly showed the foramen of Monro. And measurements about the bodies of lateral ventricles were on image, 20 mm above the image of anterior horn. Correlations of various width and areas were calculated. Then we proposed new indices with high correlations (over 0.9) with ventricular area; Anterior horn CVI (Cerebro-Ventricular Index) and Body CVI. 2) Patients with myotonic dystrophy show cerebral atrophy. We carried out the CT scan (GECT/T 8800) on 17 myotonic dystrophy patients and 30 controls. Between the two groups, age and sex were almost matched. In the two groups, we calculated our new indices as well as various indices which have been reported; Huckman number, Bifrontal CVI, Bicaudal CVI, Anterior horn index, Hirajima's index, and Cella-media index. The data were analyzed statistically. The ventricular dilatation of myotonic dystrophy patients is more definite with Anterior horn CVI, Bicaudal CVI and Body CVI (p<0.01). These indices have higher correlations with the ventricular area (about 0.9). (J.P.N.)

  16. A case of pineal teratoma with intraventricular free fat on CT scan

    International Nuclear Information System (INIS)

    Uede, Teiji; Takaya, Satoru; Shinya, Toshiyuki; Tanabe, Sumiyoshi; Hashi, Kazuo; Sohma, Tsutomu.

    1986-01-01

    Detection of an intraventricular or intratumoral fat-fluid level on the plain craniograms has been known as a characteristic sign indicating the presence of intracranial teratomatous tumors. On CT scans, however, only thirteen cases have been previously reported to be found an intraventricular and/or subarachnoid free fat associated with spontaneous ruptures of these tumors. We reported a case of pineal teratoma with intraventricular free-fat seen on CT scans. A nine-year-old male with precocious puberty was admitted to our hospital complaining a moderate nonpulsatile headache. Neurological examinations were normal without signs of meningeal irritation. The serum and CSF titer of HCG were raised markedly. The laboratory data of the CSF were normal and there were no pathological cells in the CSF. The CT scans revealed a large heterogeneous mass containing multiple areas of negative density in the pineal region. There were negative density droplets in the bilateral frontal horn on the same CT scans indicating a presence of free fats. At surgery, an yellowish oily material was drained from the tumor, but there was no sign of meningitis over the cortical surface of the occipital lobe. An intraventricular free fat on CT scan have been reported in fourteen cases including ours following the first case described by Fawcitt in 1976. Although most of the cases presented headache, only two cases was diagnosed clinically as chemical meningitis. Pathological changes indicating granulomatous meningitis, however, were noted in five cases, all of them presenting seizure attacks. (author)

  17. [Diagnostic imaging and acute abdominal pain].

    Science.gov (United States)

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  18. Colon distension and scan protocol for CT-colonography: an overview

    NARCIS (Netherlands)

    Boellaard, Thierry N.; de Haan, Margriet C.; Venema, Henk W.; Stoker, Jaap

    2013-01-01

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension,

  19. Brain tumors and CT scan in infants and children, (1). The impact on pediatric neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Ohi, S; Velasco, J M [Northwestern Univ., Chicago, IL (USA). Medical School

    1980-10-01

    The dramatic change in the neuroradiological procedures have been noted after CT scan was introduced in the last several years. Remarkable decreasing numbers of angiographic, pneumoencephalographic and other invasive neuroradiologic studies as well as nuclear brain scan were also found in the pediatric neuroradiology. The authors analyzed the total numbers of these studies performed in the last several years in pediatric neurological/neurosurgical practice in the light of the impact of CT scan especially in the diagnostic procedures and treatments of brain tumor in children. Although the number of these procedures decreased up to 49% in plain skull X-ray, 54% in cerebral angiography, 70% in pneumoencephalography/ventriculography and 79% in nuclear brain scan after CT scan was installed in our results, it is extremely important to renew understanding of those characteristics in each special procedures. Cerebral angiography as well as pneumoencephalography may give the surgeon more precise ideas of the anatomical relationship between the lesion and other normal structures, especially in the posterior fossa tumor in which CT scan occassionally demonstrates only a gross finding. A case with false negative result and another case with a complicated anatomical structure in CT scan were presented. The significance of cerebral angiography and other invasive studies in the diagnosis and follow up of brain tumor in CT scan were discussed.

  20. Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT

    International Nuclear Information System (INIS)

    Engelbrecht, V.; Koch, J.A.; Rassek, M.; Moedder, U.

    1996-01-01

    To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of X-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. The phantom study revealed a 38,4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required. (orig.) [de

  1. Comparison of absorbed dose of two protocols of tomographic scanning in PET/CT exams

    International Nuclear Information System (INIS)

    Paiva, F.G.

    2017-01-01

    Positron Emission Tomography (PET) associated with Computed Tomography (CT) allows the fusion of functional and anatomical images. When compared to other diagnostic techniques, PET-CT subjects patients to higher levels of radiation, because two modalities are used in a single exam. In this study, the doses absorbed in 19 patient organs from the tomographic scan were evaluated. Radiochromic films were correctly positioned in the Alderson anthropomorphic simulator, male version. For evaluation, two whole body scan protocols were compared. For evaluation, two whole body scan protocols were compared. An increase of up to 600% in the absorbed dose in the pituitary was observed when the protocols were compared, with the lowest observed increase of approximately 160% for the liver. It is concluded that the dose from CT in patients submitted to PET-CT scanning is higher in the protocol used for diagnosis. Considering the high cost of PET-CT exam, in many cases it is preferable that the CT examination is of diagnostic quality, and not only for anatomical mapping, an argument based on the Principle of Justification

  2. Hernia Following Blunt Abdominal Trauma

    Directory of Open Access Journals (Sweden)

    N Aghaie

    2009-10-01

    Full Text Available Traumatic abdominal wall hernia is a rare type of hernia, which follows blunt trauma to the abdomen, where disruption of the musculature and fascia occurs with the overlying skin remaining intact. Diagnosis of this problem is very difficult and delayed. Traumatic hernia is often diagnosed during laparatomy or laparascopy, but CT scan also has a role in distinguishing this pathology. Delay in diagnosis is very dangerous and can result in gangrene and necrosis of the organs in the hernia. The case report of a 35 years old man with liftruck blunt trauma is reported. His vital signs were stable. On physical examination, tenderness of RUQ was seen. He underwent Dpl for suspected hemoprotein. Dpl was followed up by laparatomy. Laparatomy revealed that the transverse and ascending colon partially herniated in the abdominal wall defect. The colon was reduced in the abdomen and repair of abdominal hernia was done. The patient was discharged after 5 day. The etiology, pathogenesis and management are discussed.

  3. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog; Kim, Dae Young; Yu, Pil Mun

    1992-01-01

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern

  4. Mediastinal lymph node enlargement on CT scans in idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Joong Mo; Im, Jung Gi; Yu, Kyu In; Kim, Hyeong Seog [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dae Young [Chung Buk National University College of Medicine, Chungju (Korea, Republic of); Yu, Pil Mun [Dankuk University College of Medicine, Seoul (Korea, Republic of)

    1992-09-15

    The increase in size of lymph node on CT scan is the single most important finding of lymphadenopathy. The purpose of this study was to evaluate the size of mediastinal lymph nodes in patients with idiopathic pulmonary fibrosis with no evidence of malignancy or current infection. CT scans of 70 patients (16 with conventional CT and 54 with high-resolution CT) were assessed for lymph node size and location. The duration of symptoms, and the extent and pattern of the parenchymal lung disease on CT scans were correlated with lymph node enlargement. In 54 of 70 patients, more than one lymph nodes were large than 1-1.5 cm. The prevalence of node enlargement increased significant with a longer duration of symptom (p=0.001), large extent of the disease (p=0.043), and with a greater proportion of honeycomb pattern (p=0.033). Right paratracheal, subcarinal, right tracheobronchial, and paraesophageal nodes were the most common sites of node enlargement. In conclusion, mediastinal lymph node enlargement is common in patients with idiopathic pulmonary fibrosis and is more frequently seen in patients with a longer duration of clinical symptoms, greater extent of the disease, and with a larger proportion of honeycomb pattern.

  5. Increased inspiratory pressure for reduction of atelectasis in children anesthetized for CT scan

    International Nuclear Information System (INIS)

    Sargent, Michael A.; Jamieson, Douglas H.; McEachern, Anita M.; Blackstock, Derek

    2002-01-01

    Background: Atelectasis is more frequent and more severe in children anesthetized for CT scan than it is in children sedated for CT scan.Objective: To determine the effect of increased inspiratory pressure on atelectasis during chest CT in anesthetized children. Materials and methods: Atelectasis on chest CT was assessed by two observers in three groups of patients. Group A comprised 13 children (26 lungs) anesthetized at inspiratory pressures up to and including 25 cm H 2 O. Group B included 11 children anesthetized at inspiratory pressures ≥30 cm H 2 O. Group C included 8 children under deep sedation. Results: Atelectasis was significantly more severe in group A than in groups B and C. There was no significant difference between groups B and C. Conclusion: An inspiratory pressure of 30 cm H 2 O is recommended for children anesthetized for CT scan of the chest. (orig.)

  6. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    Science.gov (United States)

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  7. Technological features and clinical feasibility of megavoltage CT scanning

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Akanuma, Atsuo; Sakata, Kouichi; Karasawa, Katsuyuki; Terahara, Atsurou; Onogi, Yuzou; Hasezawa, Kenji; Sasaki, Yasuhito

    1992-01-01

    Megavoltage CT scanning using 4-MV and 6-MV radiotherapy beams has been developed and applied to verify errors in patient positioning. A detector system composed of 120 pairs of cadmium tungstate scintillators with photodiodes is mounted to the treatment unit at a distance of 160 cm from the beam source. Image reconstruction is performed with a standard filtered back-projection algorithm. Scanning time and reconstruction time for a slice is approximately 35 s and 60 s respectively. Although spatial resolution is as large as 4 mm, it has sufficient image quality to be applied for treatment planning and verification. The delivered dose with 4 MV and 6 MV is about 1.4 cGy and 2.8 cGy respectively. When a megavoltage CT image is taken in treatment position, the positioning errors are easily detected by comparing it with diagnostic CT sections for treatment planning. Several clinical examples are presented. (orig.)

  8. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  9. Interfraction Liver Shape Variability and Impact on GTV Position During Liver Stereotactic Radiotherapy Using Abdominal Compression

    International Nuclear Information System (INIS)

    Eccles, Cynthia L.; Dawson, Laura A.; Moseley, Joanne L.; Brock, Kristy K.

    2011-01-01

    Purpose: For patients receiving liver stereotactic body radiotherapy (SBRT), abdominal compression can reduce organ motion, and daily image guidance can reduce setup error. The reproducibility of liver shape under compression may impact treatment delivery accuracy. The purpose of this study was to measure the interfractional variability in liver shape under compression, after best-fit rigid liver-to-liver registration from kilovoltage (kV) cone beam computed tomography (CBCT) scans to planning computed tomography (CT) scans and its impact on gross tumor volume (GTV) position. Methods and Materials: Evaluable patients were treated in a Research Ethics Board-approved SBRT six-fraction study with abdominal compression. Kilovoltage CBCT scans were acquired before treatment and reconstructed as respiratory sorted CBCT scans offline. Manual rigid liver-to-liver registrations were performed from exhale-phase CBCT scans to exhale planning CT scans. Each CBCT liver was contoured, exported, and compared with the planning CT scan for spatial differences, by use of in house-developed finite-element model-based deformable registration (MORFEUS). Results: We evaluated 83 CBCT scans from 16 patients with 30 GTVs. The mean volume of liver that deformed by greater than 3 mm was 21.7%. Excluding 1 outlier, the maximum volume that deformed by greater than 3 mm was 36.3% in a single patient. Over all patients, the absolute maximum deformations in the left-right (LR), anterior-posterior (AP), and superior-inferior directions were 10.5 mm (SD, 2.2), 12.9 mm (SD, 3.6), and 5.6 mm (SD, 2.7), respectively. The absolute mean predicted impact of liver volume displacements on GTV by use of center of mass displacements was 0.09 mm (SD, 0.13), 0.13 mm (SD, 0.18), and 0.08 mm (SD, 0.07) in the left-right, anterior-posterior, and superior-inferior directions, respectively. Conclusions: Interfraction liver deformations in patients undergoing SBRT under abdominal compression after rigid liver

  10. Nodo-colonic fistula caused by intra-abdominal tuberculous lymphadenitis during treatment with anti-tuberculous medication: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Kyung Sun; Bae, Kyung Eun; Jeong, Myeong Ja; Lee, Ji Hae; Kang, Mi Jin; Kim, Jae Hyung; Kim, Soo Hyun [Dept. of Radiology, Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2016-08-15

    Recently, the overall incidence of tuberculosis has decreased, but the incidence of an extrapulmonary manifestation in patients with tuberculosis has increased in the Republic of Korea. Although intestinal tuberculosis is not infrequent, a fistula caused by tuberculosis is a rare condition. A 23-year-old man presented with fever, diarrhea and right lower quadrant pain. A computed tomography (CT) scan revealed a lobulated, peripherally enhancing, low density mass in the mesentery. The patient underwent laparoscopic biopsy for necrotic lymph node, and intra-abdominal tuberculous lymphadenitis was diagnosed. Four months after initiating treatment with anti-tuberculous medication, the patient developed fever together with lower abdominal pain. A follow-up CT scan revealed a fistulous tract that had developed between the initially noted lymphadenopathy and the proximal ascending colon. Laparoscopic right hemicolectomy was performed as a curative treatment. This case suggests that a nodo-colonic fistula may occur as a paradoxical response in patients with intra-abdominal tuberculous lymphadenitis during treatment with anti-tuberculous medication.

  11. Centre for Industrial Application of CT scanning (CIA-CT) – Four years of results 2009-2013

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Andreasen, Jan Lasson; Christensen, Lars Bager

    activities: Centre of Excellence, Dissemination, Collaboration, Research, and Initiation of new activities. The consortium has consisted of nine partners, including three research institutions, two consultancy partners, two large companies, and two small / medium enterprises. The consortium has acted......The innovation consortium project, carried out September 2009 – August 2013, has aimed to help the participating companies and Danish industry with the introduction of CT scanning as measuring technology, carrying out research at international level. The project has operated through five main...... as a centre of excellence for industrial CT scanning, both nationally and internationally. A network with approx. 40 participants has been established, and a total of 22 students have been educated. Dissemination activities have encompassed: a web page www.cia-ct.mek.dtu.dk , 8 newsletters, 4 topical...

  12. Opportunistic screening for osteoporosis by routine CT in Southern Europe.

    Science.gov (United States)

    Alacreu, Elena; Moratal, David; Arana, Estanislao

    2017-03-01

    Feasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost. The purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive. Cohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 ± 12.38 years (mean ± standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated. BMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R 2  = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores. Abdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can

  13. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  14. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  15. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

    International Nuclear Information System (INIS)

    Wolthaus, J. W. H.; Sonke, J.-J.; Herk, M. van; Damen, E. M. F.

    2008-01-01

    Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good

  16. CT SCAN EVALUATION OF PULMONARY NODULE

    Directory of Open Access Journals (Sweden)

    A. Ravi Kumar

    2016-06-01

    Full Text Available BACKGROUND Lung carcinomas are quite commonly diagnosed. Thanks to the ever increasing smokers’ population. Majority of the city dwellers are at a higher risk of having this disease when compared to the village counterparts. The stigma through which the person and the family have to undergo before confirming the diagnosis is enormous. So the radiographic methods of diagnosing the malignancies have to improve. Before confirming the diagnosis, the radiologists, the treating physicians should be somewhat confident about the diagnosis so as to prepare the patients and their relatives for the most probable diagnosis before the confirmatory report. The confirmatory procedures include the PET scan and the Histopathology. Both are time consuming procedures and in an economy like ours, finding a PET scanning centre is rather difficult. So the most probable diagnosis has to be thought of using minimal resource. This study puts in a sincere effort to understand and evaluate the pulmonary nodule when identified by a CT scan. This paper is intended to help the practicing radiologists and also make life easy for a practicing physician to identify correctly the lesions and also help the patients to prevent further progression of the disease. METHODS The study was a cross-sectional study. The sample size of the study consisted of thirty patients. CT scan was done in thirty patients who were identified to have lung nodules either by other mode of radiological studies or first time identified in a CT scan itself. The study was conducted in Fathima Institute of Medical Sciences, Kadapa. The study was conducted from 2014 to 2015. RESULT Non-solid nodules were more in number when compared to the solid nodules. All the non-solid nodules were confirmed to be adenomas. Eighty percent of the nodules which were more than 8 mm in size were confirmed to be malignant. One hundred percent of the spiculated border on CT was confirmed to be malignant. In the present study

  17. Ketamine-associated CT findings of damage in liver and gall and urinary system

    International Nuclear Information System (INIS)

    Zhang Keyun; Wang Lijuan; Wang Jiajun; Cheng Kuishan; Chen Aidi; Xu Dasheng

    2011-01-01

    Objective: To investigate the image signs of damage e in urinary system and liver and gall system and diagnostic value of CT findings in abuse of ketamine. Methods: With ethics committee approval, a retrospective analysis of 10 patients with a history of taking K powder (1 to 10 years) was done with abdominal CT scan and enhanced scan data to analysis the imaging findings of ketamine-related abdominal organ damage. Results: CT images of the 10 patients showed different degrees of reduced bladder capacity, bladder wall thickening range of 3∼14 mm. Of which the wall were thickened on both sides with the waist-shaped in 5 patients. Bilateral hydronephrosis and hydroureterosis was found in 3 cases with uniform wall thickening of both ureters. 4 cases of renal multi-lesion papillary necrosis was found, of which 2 patients showed multi-lesion ischemic changes in renal parenchyma in both kidneys. Expansion of the common bile duct appeared in 3 cases, of which 2 cases with merger intrahepatic bile duct dilation. Conclusion: CT findings of ketamine associated abdominal organ injuries in the bladder and renal may have certain characteristics. It is helpful to make diagnosis with the combination of favorable clinical data and medical history. (authors)

  18. Diagnostic Accuracy of Secondary Ultrasound Exam in Blunt Abdominal Trauma

    International Nuclear Information System (INIS)

    Rajabzadeh Kanafi, Alireza; Giti, Masoumeh; Gharavi, Mohammad Hossein; Alizadeh, Ahmad; Pourghorban, Ramin; Shekarchi, Babak

    2014-01-01

    In stable patients with blunt abdominal trauma, accurate diagnosis of visceral injuries is crucial. To determine whether repeating ultrasound exam will increase the sensitivity of focused abdominal sonography for trauma (FAST) through revealing additional free intraperitoneal fluid in patients with blunt abdominal trauma. We performed a prospective observational study by performing primary and secondary ultrasound exams in blunt abdominal trauma patients. All ultrasound exams were performed by four radiology residents who had the experience of more than 400 FAST exams. Five routine intraperitoneal spaces as well as the interloop space were examined by ultrasound in order to find free fluid. All patients who expired or were transferred to the operating room before the second exam were excluded from the study. All positive ultrasound results were compared with intra-operative and computed tomography (CT) findings and/or the clinical status of the patients. Primary ultrasound was performed in 372 patients; 61 of them did not undergo secondary ultrasound exam; thus, were excluded from the study.Three hundred eleven patients underwent both primary and secondary ultrasound exams. One hundred and two of all patients were evaluated by contrast enhanced CT scan and 31 underwent laparotomy. The sensitivity of ultrasound exam in detecting intraperitoneal fluid significantly increased from 70.7% for the primary exam to 92.7% for the secondary exam. Examining the interloop space significantly improved the sensitivity of ultrasonography in both primary (from 36.6% to 70.7%) and secondary (from 65.9% to 92.7%) exams. Performing a secondary ultrasound exam in stable blunt abdominal trauma patients and adding interloop space scan to the routine FAST exam significantly increases the sensitivity of ultrasound in detecting intraperitoneal free fluid

  19. Iterative reconstruction reduces abdominal CT dose

    International Nuclear Information System (INIS)

    Martinsen, Anne Catrine Trægde; Sæther, Hilde Kjernlie; Hol, Per Kristian; Olsen, Dag Rune; Skaane, Per

    2012-01-01

    Objective: In medical imaging, lowering radiation dose from computed tomography scanning, without reducing diagnostic performance is a desired achievement. Iterative image reconstruction may be one tool to achieve dose reduction. This study reports the diagnostic performance using a blending of 50% statistical iterative reconstruction (ASIR) and filtered back projection reconstruction (FBP) compared to standard FBP image reconstruction at different dose levels for liver phantom examinations. Methods: An anthropomorphic liver phantom was scanned at 250, 185, 155, 140, 120 and 100 mA s, on a 64-slice GE Lightspeed VCT scanner. All scans were reconstructed with ASIR and FBP. Four readers evaluated independently on a 5-point scale 21 images, each containing 32 test sectors. In total 672 areas were assessed. ROC analysis was used to evaluate the differences. Results: There was a difference in AUC between the 250 mA s FBP images and the 120 and 100 mA s FBP images. ASIR reconstruction gave a significantly higher diagnostic performance compared to standard reconstruction at 100 mA s. Conclusion: A blending of 50–90% ASIR and FBP may improve image quality of low dose CT examinations of the liver, and thus give a potential for reducing radiation dose.

  20. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography

    International Nuclear Information System (INIS)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J.; Stahel, P.F.; Ertel, W.

    2004-01-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)