WorldWideScience

Sample records for abdominal aortic repair

  1. Is Conventional Open Repair for Abdominal Aortic Aneurysm Feasible in Nonagenarians?

    Science.gov (United States)

    Uehara, Kyokun; Matsuda, Hitoshi; Inoue, Yosuke; Omura, Atsushi; Seike, Yoshimasa; Sasaki, Hiroaki; Kobayashi, Junjiro

    2017-09-25

    Background : Although endovascular repair for abdominal aortic aneurysm has been found to be beneficial in very elderly patients, some patients have contraindications to this procedure. For nonagenarians, the results of open repair remain unclear. The purpose of this study was to compare the outcomes of open vs. endovascular repair for abdominal aortic aneurysm in nonagenarian patients. Methods and Results : Fourteen patients undergoing open surgical repair and 24 undergoing endovascular repair for abdominal aortic aneurysm were evaluated. There was no significant difference in early mortality between the open and endovascular groups (0% vs. 4.1%, p=0.16). The open repair group required much longer hospital stays (26.4 vs. 10.6 days, respectively, p=0.003). Finally, 12 patients (86%) undergoing open repair vs. 21 (88%) undergoing endovascular repair returned home (p=0.49). During a mean follow-up period of 23.4±23.5 months, cumulative estimated 1- and 3-year survival rates were 90.0% and 48.0%, respectively in the open repair group and 90.6% and 54.9%, respectively in the endovascular repair group (p=0.51). Conclusion : Although endovascular repair for abdominal aortic aneurysm was superior in terms of recovery, the results of conventional open repair were acceptable even in nonagenarian patients. Open repair remains an alternative for patients with contraindications to endovascular repair.

  2. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    Ultee, Klaas H J; Hurks, Rob; Buck, Dominique B.; Dasilva, George S.; Soden, Peter A.; Van Herwaarden, Joost A.; Verhagen, Hence J M; Schermerhorn, Marc L.

    2015-01-01

    Background Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion of AAA

  3. The impact of endovascular repair on specialties performing abdominal aortic aneurysm repair

    NARCIS (Netherlands)

    K.H.J. Ultee (Klaas); R. Hurks (Rob); D.B. Buck (Dominique B.); G.S. Dasilva (George S.); P.A. Soden (Peter A.); J.A. van Herwaarden (Joost); H.J.M. Verhagen (Hence); M.L. Schermerhorn (Marc)

    2015-01-01

    textabstractBackground Abdominal aortic aneurysm (AAA) repair has been performed by various surgical specialties for many years. Endovascular aneurysm repair (EVAR) may be a disruptive technology, having an impact on which specialties care for patients with AAA. Therefore, we examined the proportion

  4. Combined Repair of Ascending Aortic Pseudoaneurysm and Abdominal Aortic Aneurysm in a Patient with Marfan Syndrome

    OpenAIRE

    Kokotsakis, John N.; Lioulias, Achilleas G.; Foroulis, Christophoros N.; Skouteli, Eleni Anna T.; Milonakis, Michael K.; Bastounis, Elias A.; Boulafendis, Dimitrios G.

    2003-01-01

    Pseudoaneurysms of the ascending aorta after the original inclusion/wrap technique of the Bentall procedure present a difficult surgical management problem and are associated with substantial morbidity and mortality. Patients with Marfan syndrome frequently develop aneurysms and dissections that involve multiple aortic segments. We present the case of a Marfan patient who successfully underwent repair of a giant ascending aortic pseudoaneurysm and concomitant repair of an abdominal aortic ane...

  5. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  6. Simultaneous repair of abdominal aortic aneurysm and resection of unexpected, associated abdominal malignancies.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Lorusso, Riccardo; Ceccanei, Gianluca; Vietri, Francesco

    2004-12-15

    The management of unexpected intra-abdominal malignancy, discovered at laparotomy for elective treatment of an abdominal aortic aneurysm (AAA), is controversial. It is still unclear whether both conditions should be treated simultaneously or a staged approach is to be preferred. To contribute in improving treatment guidelines, we retrospectively reviewed the records of patients undergoing laparotomy for elective AAA repair. From January 1994 to March 2003, 253 patients underwent elective, trans-peritoneal repair of an AAA. In four patients (1.6%), an associated, unexpected neoplasm was detected at abdominal exploration, consisting of one renal, one gastric, one ileal carcinoid, and one ascending colon tumor. All of them were treated at the same operation, after aortic repair and careful isolation of the prosthetic graft. The whole series' operative mortality was 3.6%. None of the patients simultaneously treated for AAA and tumor resection died in the postoperative period. No graft-related infections were observed. Simultaneous treatment of AAA and tumor did not prolong significantly the mean length of stay in the hospital, compared to standard treatment of AAA alone. Except for malignancies of organs requiring major surgical resections, simultaneous AAA repair and resection of an associated, unexpected abdominal neoplasm can be safely performed, in most of the patients, sparing the need for a second procedure. Endovascular grafting of the AAA can be a valuable tool in simplifying simultaneous treatment, or in staging the procedures with a very short delay.

  7. A case of acute ischemic colitis after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Grigorios Voulalas

    2016-01-01

    Full Text Available Colonic ischemia is a recognized complication of either open or endovascular abdominal aortic aneurysm repair. The clinical difficulty in establishing the diagnosis, the severity of this complication and the patient's poor physiological status may lead to a fatal outcome. We presented a case of ischemic colitis in a patient with patent hypogastric arteries that occurred after an endovascular abdominal aortic aneurysm repair as well as a review of the available literature. The patient's preoperative, intraoperative and postoperative data were recorded. A thorough search through the Google data and Medline to review similar cases or any analyses that referred to ischemic colitis after endovascular abdominal aneurysm repair was conducted. A 76-year-old male was admitted to our department for an elective endovascular repair of an 8 cm in diameter abdominal aortic aneurysm. A Zenith bifurcation graft was implanted. The whole procedure was uneventful and the final angiogram showed an accurate deployment of the endograft without endoleaks and patency of both hypogastric arteries. During the 1st postoperative day, the patient developed symptoms of acute abdomen in combination with metabolic acidosis and oliguria. He underwent an exploratory laparotomy, which revealed necrosis of the sigmoid. A Hartmann's procedure was performed; the patient was transferred to the intensive care unit where he deceased after 24 h. Postoperative ischemic colitis has been described after open abdominal aneurysm repair. The description of this complication has been reported since the early phase of endovascular abdominal aneurysm repair development with a current incidence of 1.5%–3.0%. Possible mechanisms that may contribute to ischemic colitis in spite of the presence of patent hypogastric arteries include atheroembolization, shock, vasopressive drugs and inferior mesenteric artery occlusion.

  8. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  9. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  10. Outcome after endovascular abdominal aortic aneurysm repair: a meta-analysis.

    NARCIS (Netherlands)

    Walschot, L.H.B.; Laheij, R.J.F.; Verbeek, A.L.M.

    2002-01-01

    PURPOSE: To determine the frequencies of complications and risk factors for complications following endovascular abdominal aortic aneurysm (AAA) repair (EVAR). METHODS: Thirty-nine articles published between October 1995 and October 1999 in English, German, French, or Dutch were identified in

  11. Combined Repair of Ascending Aortic Pseudoaneurysm and Abdominal Aortic Aneurysm in a Patient with Marfan Syndrome

    Science.gov (United States)

    Kokotsakis, John N.; Lioulias, Achilleas G.; Foroulis, Christophoros N.; Skouteli, Eleni Anna T.; Milonakis, Michael K.; Bastounis, Elias A.; Boulafendis, Dimitrios G.

    2003-01-01

    Pseudoaneurysms of the ascending aorta after the original inclusion/wrap technique of the Bentall procedure present a difficult surgical management problem and are associated with substantial morbidity and mortality. Patients with Marfan syndrome frequently develop aneurysms and dissections that involve multiple aortic segments. We present the case of a Marfan patient who successfully underwent repair of a giant ascending aortic pseudoaneurysm and concomitant repair of an abdominal aortic aneurysm. An aggressive surgical strategy followed by life-long cardiovascular monitoring is warranted in order to prolong the survival of these patients. (Tex Heart Inst J 2003;30:233–5) PMID:12959210

  12. Extra-anatomic endovascular repair of an abdominal aortic aneurysm with a horseshoe kidney supplied by the aneurysmal aorta.

    Science.gov (United States)

    Rey, Jorge; Golpanian, Samuel; Yang, Jane K; Moreno, Enrique; Velazquez, Omaida C; Goldstein, Lee J; Chahwala, Veer

    2015-07-01

    Abdominal aortic aneurysm complicated by a horseshoe kidney (HSK, fused kidney) represents a unique challenge for repair. Renal arteries arising from the aneurysmal aorta can further complicate intervention. Reports exist describing the repair of these complex anatomies using fenestrated endografts, hybrid open repairs (debranching), and open aneurysmorrhaphy with preservation of renal circulation. We describe an extra-anatomic, fully endovascular repair of an abdominal aortic aneurysm with a HSK partially supplied by a renal artery arising from the aneurysm. We successfully applied aortouni-iliac endografting, femorofemoral bypass, and retrograde renal artery perfusion via the contralateral femoral artery to exclude the abdominal aortic aneurysm and preserve circulation to the HSK. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Outcomes after open repair for ruptured abdominal aortic aneurysms in patients with friendly versus hostile aortoiliac anatomy

    NARCIS (Netherlands)

    van Beek, S. C.; Reimerink, J. J.; Vahl, A. C.; Wisselink, W.; Reekers, J. A.; Legemate, D. A.; Balm, R.

    2014-01-01

    In patients with a ruptured abdominal aortic aneurysm (RAAA), anatomic suitability for endovascular aneurysm repair (EVAR) depends on aortic neck and iliac artery characteristics. If the aortoiliac anatomy is unsuitable for EVAR ("hostile anatomy"), open repair (OR) is the next option. We

  14. Embolization by micro navigation for treatment of persistent type 2 Endoleaks after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Bruno Lorenção de Almeida

    2014-12-01

    Full Text Available Background:Endovascular repair has become established as a safe and effective method for treatment of abdominal aortic aneurysms. One major complication of this treatment is leakage, or endoleaks, of which type 2 leaks are the most common.Objective:To conduct a brief review of the literature and evaluate the safety and effectiveness of embolization by micronavigation for treatment of type 2 endoleaks.Method:A review of medical records from patients who underwent endovascular repair of abdominal aortic aneurysms identified 5 patients with persistent type 2 endoleaks. These patients were submitted to embolization by micronavigation.Results:In all cases, angiographic success was achieved and control CT scans showed absence of type 2 leaks and aneurysm sacs that had reduced in size after the procedure.Conclusion:Treatment of type 2 endoleaks using embolization by micronavigation is an effective and safe method and should be considered as a treatment option for this complication after endovascular repair of abdominal aortic aneurysms.

  15. The effect of endograft device on patient outcomes in endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2017-12-01

    Objective Endovascular aneurysm repair for ruptured abdominal aortic aneurysm is being increasingly applied as the intervention of choice. The purpose of this study was to determine whether survival and reintervention rates after ruptured abdominal aortic aneurysm vary between endograft devices. Methods This cohort study identified all ruptured abdominal aortic aneurysms performed at The Ottawa Hospital from January 1999 to May 2015. Data collected included patient demographics, stability index at presentation, adherence to device instructions for use, endoleaks, reinterventions, and mortality. Kruskal-Wallis test was used to compare outcomes between groups. Mortality outcomes were assessed using Kaplan-Meier survival analysis, and multivariate Cox regression modeling. Results One thousand sixty endovascular aneurysm repairs were performed using nine unique devices. Ninety-six ruptured abdominal aortic aneurysms were performed using three devices: Cook Zenith ( n = 46), Medtronic Endurant ( n = 33), and Medtronic Talent ( n = 17). The percent of patients presented in unstable or extremis condition was 30.2, which did not differ between devices. Overall 30-day mortality was 18.8%, and was not statistically different between devices ( p = 0.16), although Medtronic Talent had markedly higher mortality (35.3%) than Cook Zenith (15.2%) and Medtronic Endurant (15.2%). AUI configuration was associated with increased 30-day mortality (33.3% vs. 12.1%, p = 0.02). Long-term mortality and graft-related reintervention rates at 30 days and 5 years were similar between devices. Instructions for use adherence was similar across devices, but differed between the ruptured abdominal aortic aneurysm and elective endovascular aneurysm repair cohorts (47.7% vs. 79.0%, p 30 days post-endovascular aneurysm repair ( p = 0.01). Type 1 endoleak rates differed significantly across devices (Cook Zenith 0.0%, Medtronic Endurant 18.2%, Medtronic Talent 17.6%, p = 0

  16. Near-infrared spectroscopy assessed cerebral oxygenation during open abdominal aortic aneurysm repair

    DEFF Research Database (Denmark)

    Sørensen, H.; Nielsen, Henning Morris Bay; Secher, N H

    2016-01-01

    During open abdominal aortic aneurism (AAA) repair cerebral blood flow is challenged. Clamping of the aorta may lead to unintended hyperventilation as metabolism is reduced by perfusion of a smaller part of the body and reperfusion of the aorta releases vasodilatory substances including CO2. We i...

  17. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis; Wisniowski, Brendan; Walker, Philip J.; Bradshaw, Barbara; Golledge, Jonathan

    2014-01-01

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  18. Abdominal aortic aneurysm calcification and thrombus volume are not associated with outcome following endovascular abdominal aortic aneurysm repair

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Divyajeet; Velu, Ramesh; Tosenovsky, Patrik; Quigley, Francis [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); Wisniowski, Brendan; Walker, Philip J. [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia); Bradshaw, Barbara [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); Golledge, Jonathan [James Cook University, Queensland Research Centre for Peripheral Vascular Disease, School of Medicine and Dentistry, Townsville, Queensland (Australia); The Townsville Hospital, Department of Vascular and Endovascular Surgery, Douglas (Australia); University of Queensland, School of Medicine and Centre for Clinical Research, Department of Vascular Surgery, Royal Brisbane and Women' s Hospital, Herston, QLD (Australia)

    2014-08-15

    Aortic calcification and thrombus have been postulated to worsen outcome following endovascular abdominal aortic aneurysm repair (EVAR). The purpose of this study was to assess the association of abdominal aortic aneurysm (AAA) calcification and thrombus volume with outcome following EVAR using a reproducible, quantifiable computed tomography (CT) assessment protocol. Patients with elective EVAR performed between January 2002 and 2012 at the Townsville Hospital, Mater Private Hospital (Townsville) and Royal Brisbane and Women's Hospital (RBWH) were included if preoperative CTAs were available for analysis. AAA calcification and thrombus volume were measured using a semiautomated workstation protocol. Outcomes were assessed in terms of clinical failure, endoleak (type I, type II) and reintervention. Univariate and multivariate analyses were performed. Median follow-up was 1.7 years and the interquartile range 1.0-3.8 years. One hundred thirty-four patients undergoing elective EVAR were included in the study. Rates of primary clinical success and freedom from reintervention were 82.8 % and 88.9 % at the 24-month follow-up. AAA calcification and thrombus volume were not associated with clinical failure, type I endoleak, type II endoleak or reintervention. AAA calcification and thrombus volume were not associated with poorer outcome after EVAR in this study. (orig.)

  19. Treatment strategy for ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  20. Logistic considerations for a successful institutional approach to the endovascular repair of ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Mayer, Dieter; Rancic, Zoran; Pfammatter, Thomas; Hechelhammer, Lukas; Veith, Frank J; Donas, Konstantin; Lachat, Mario

    2010-01-01

    The value of emergency endovascular aneurysm repair (EVAR) in the setting of ruptured abdominal aortic aneurysm remains controversial owing to differing results. However, interpretation of published results remains difficult as there is a lack of generally accepted protocols or standard operating procedures. Furthermore, such protocols and standard operating procedures often are reported incompletely or not at all, thereby making interpretation of results difficult. We herein report our integrated logistic system for the endovascular treatment of ruptured abdominal aortic aneurysms. Important components of this system are prehospital logistics, in-hospital treatment logistics, and aftercare. Further studies should include details about all of these components, and a description of these logistic components must be included in all future studies of emergency EVAR for ruptured abdominal aortic aneurysms.

  1. Treatment of abdominal aortic aneurysm in nine countries 2005-2009: a vascunet report

    DEFF Research Database (Denmark)

    Mani, K; Lees, T; Beiles, B

    2011-01-01

    To study contemporary treatment and outcome of abdominal aortic aneurysm (AAA) repair in nine countries.......To study contemporary treatment and outcome of abdominal aortic aneurysm (AAA) repair in nine countries....

  2. Endovascular abdominal aortic aneurysm repair complicated by spondylodiscitis and iliaco-enteral fistula.

    Science.gov (United States)

    de Koning, Heleen D; van Sterkenburg, Steven M M; Pierie, Maurice E N; Reijnen, Michel M P J

    2008-06-01

    Infections of abdominal aortic endografts are rare. There are no reports on the association with spondylodiscitis. We report a case of a 74-year-old man who underwent endovascular aneurysm repair (EVAR) and subsequently femorofemoral bypass placement due to occlusion of the right limb of the endograft. Six months later, he presented with rectal bleeding, weight loss, back pain, and low abdominal pain. Computed tomography revealed extensive abscess formation with air in and around the endograft and psoas muscles, in continuity with destructive spondylodiscitis L3-4. There was a small bowel loop in close proximity to the occluded right leg of the endograft, which was filled with air bubbles. An axillofemoral bypass was created followed by a laparotomy. Intra-operatively, an iliaco-enteral fistula was found. The small bowel defect was sutured, the endograft completely removed, and the infrarenal aorta and both common iliac arteries were closed. Necrotic fragments of the former L3-4 disk were removed. The postoperative course was uneventful. Seven months postoperatively, the patient had recovered well. Iliaco-enteric fistula and spondylodiscitis are rare complications of aortic aneurysm repair. This is the first report of spondylodiscitis after EVAR.

  3. Duodenal Obstruction after Elective Abdominal Aortic Aneurysm Repair: A Case Report

    Directory of Open Access Journals (Sweden)

    Chun-Yao Lin

    2004-10-01

    Full Text Available Gastrointestinal tract complications after abdominal aortic aneurysm (AAA repair are well known. The reported frequency ranges from 6.6% to 21%. However, the incidence of duodenal obstruction following AAA has probably been underestimated. This report concerns a 78-year-old male who was admitted for elective repair of an infrarenal AAA. On the ninth postoperative day, the patient presented with large quantities of bile-stained vomitus despite passing flatus per rectum. Metoclopramide and ranitidine were given under the initial impression of paralytic ileus. However, the upper gastrointestinal obstruction persisted, and on day 12, computerized tomography (CT revealed marked distension of the gastric tube and duodenum, down to the level of the third portion, with abrupt change of caliber at the point of the superior mesenteric artery (SMA. SMA syndrome was diagnosed. After nasogastric tube aspiration, parenteral nutrition, and 11 days of conservative treatment, abdominal CT and upper gastrointestinal series showed no apparent duodenal obstruction. The patient was discharged on the 29th postoperative day; follow-up abdominal CT 4 months later was unremarkable.

  4. Statin use is associated with reduced all-cause mortality after endovascular abdominal aortic aneurysm repair.

    NARCIS (Netherlands)

    Leurs, L.J.; Visser, P.; Laheij, R.J.F.; Buth, J.; Harris, P.L.; Blankensteijn, J.D.

    2006-01-01

    It has been shown that preoperative statin therapy reduces all-cause and cardiovascular mortality in patients undergoing major noncardiac vascular surgery. In this report, we investigated the influence of statin use on early and late outcome following endovascular abdominal aortic aneurysm repair

  5. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  6. Emergency abdominal aortic aneurysm repair with a preferential endovascular strategy : Mortality and cost-effectiveness analysis

    NARCIS (Netherlands)

    Kapma, Marten R.; Groen, Henk; Oranen, Bjorn I.; van der Hilst, Christian S.; Tielliu, Ignace F.; Zeebregts, Clark J.; Prins, Ted R.; van den Dungen, Jan J.; Verhoeven, Eric L.

    2007-01-01

    Purpose: To assess mortality and treatment costs of a new management protocol with preferential use of emergency endovascular aneurysm repair (eEVAR) for acute abdominal aortic aneurysm (AAA). Methods: From September 2003 until February 2005, 49 consecutive patients (45 men; mean age 71 years) with

  7. Epidemiology and contemporary management of abdominal aortic aneurysms.

    Science.gov (United States)

    Ullery, Brant W; Hallett, Richard L; Fleischmann, Dominik

    2018-05-01

    Abdominal aortic aneurysm (AAA) is most commonly defined as a maximal diameter of the abdominal aorta in excess of 3 cm in either anterior-posterior or transverse planes or, alternatively, as a focal dilation ≥ 1.5 times the diameter of the normal adjacent arterial segment. Risk factors for the development of AAA include age > 60, tobacco use, male gender, Caucasian race, and family history of AAA. Aneurysm growth and rupture risk appear to be associated with persistent tobacco use, female gender, and chronic pulmonary disease. The majority of AAAs are asymptomatic and detected incidentally on various imaging studies, including abdominal ultrasound, and computed tomographic angiography. Symptoms associated with AAA may include abdominal or back pain, thromboembolization, atheroembolization, aortic rupture, or development of an arteriovenous or aortoenteric fistula. The Screening Abdominal Aortic Aneurysms Efficiently (SAAAVE) Act provides coverage for a one-time screening abdominal ultrasound at age 65 for men who have smoked at least 100 cigarettes and women who have family history of AAA disease. Medical management is recommended for asymptomatic patients with AAAs  5 mm/6 months), or presence of a fusiform aneurysm with maximum diameter of 5.5 cm or greater. Intervention for AAA includes conventional open surgical repair and endovascular aortic stent graft repair.

  8. Successful Aortic Banding for Type IA Endoleak Due to Neck Dilatation after Endovascular Abdominal Aortic Aneurysm Repair: Case Report.

    Science.gov (United States)

    Tashima, Yasushi; Tamai, Koichi; Shirasugi, Takehiro; Sato, Kenichiro; Yamamoto, Takahiro; Imamura, Yusuke; Yamaguchi, Atsushi; Adachi, Hideo; Kobinata, Toshiyuki

    2017-09-25

    A 69-year-old man with a type IA endoleak that developed approximately 21 months after endovascular abdominal aortic aneurysm repair (EVAR) of a 46 mm diameter aneurysm was referred to our department. He had impaired renal function, Parkinson's disease, and previous cerebral infarction. Computed tomography angiography showed a type IA endoleak with neck dilatation and that the aneurysm had grown to 60 mm in diameter. We decided to perform aortic banding. The type IA endoleak disappeared after banding and the patient was discharged on postoperative day 10. Aortic banding may be effective for type IA endoleak after EVAR and less invasive for high-risk patients in particular.

  9. Imaging and management of complications of open surgical repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Nayeemuddin, M.; Pherwani, A.D.; Asquith, J.R.

    2012-01-01

    Open repair is still considered the reference standard for long-term repair of abdominal aortic aneurysms (AAA). In contrast to endovascular aneurysm repair (EVAR), patients with open surgical repair of AAA are not routinely followed up with imaging. Although complications following EVAR are widely recognized and routinely identified on follow-up imaging, complications also do occur following open surgical repair. With frequent use of multi-slice computed tomography (CT) angiography (CTA) in vascular patients, there is now improved recognition of the potential complications following open surgical repair. Many of these complications are increasingly being managed using endovascular techniques. The aim of this review is to illustrate a variety of potential complications that may occur following open surgical repair and to demonstrate their management using both surgical and endovascular techniques.

  10. Transperitoneal versus retroperitoneal approach for open abdominal aortic aneurysm repair in the targeted vascular National Surgical Quality Improvement Program

    NARCIS (Netherlands)

    Buck, Dominique B.; Ultee, Klaas H J; Zettervall, Sara L.; Soden, Pete A.; Darling, Jeremy; Wyers, Mark; van Herwaarden, Joost A.; Schermerhorn, Marc L.

    Objective: We sought to compare current practices in patient selection and 30-day outcomes for transperitoneal and retroperitoneal abdominal aortic aneurysm (AAA) repairs. Methods: All patients undergoing elective transperitoneal or retroperitoneal surgical repair for AAA between January 2011 and

  11. Transient postoperative atrial fibrillation after abdominal aortic aneurysm repair increases mortality risk

    Science.gov (United States)

    Kothari, Anai N.; Halandras, Pegge M.; Drescher, Max; Blackwell, Robert H.; Graunke, Dawn M.; Kliethermes, Stephanie; Kuo, Paul C.; Cho, Jae S.

    2016-01-01

    Objective The purpose of this study was to determine whether new-onset transient postoperative atrial fibrillation (TPAF) affects mortality rates after abdominal aortic aneurysm (AAA) repair and to identify predictors for the development of TPAF. Methods Patients who underwent open aortic repair or endovascular aortic repair for a principal diagnosis AAA were retrospectively identified using the Healthcare Cost and Utilization Project-State Inpatient Database (Florida) for 2007 to 2011 and monitored longitudinally for 1 year. Inpatient and 1-year mortality rates were compared between those with and without TPAF. TPAF was defined as new-onset atrial fibrillation that developed in the postoperative period and subsequently resolved in patients without a history of atrial fibrillation. Cox proportional hazards models, adjusted for age, gender, comorbidities, rupture status, and repair method, were used to assess 1-year survival. Predictive models were built with preoperative patient factors using Chi-squared Automatic Interaction Detector decision trees and externally validated on patients from California. Results A 3.7% incidence of TPAF was identified among 15,148 patients who underwent AAA repair. The overall mortality rate was 4.3%. The inpatient mortality rate was 12.3% in patients with TPAF vs 4.0% in those without TPAF. In the ruptured setting, the difference in mortality was similar between groups (33.7% vs 39.9%, P = .3). After controlling for age, gender, comorbid disease severity, urgency (ruptured vs nonruptured), and repair method, TPAF was associated with increased 1-year postoperative mortality (hazard ratio, 1.48; P predict an individual's probability of developing TPAF at the point of care. Conclusions The development of TPAF is associated with an increased risk of mortality in patients undergoing repair of nonruptured AAA. Predictive modeling can be used to identify those patients at highest risk for developing TPAF and guide interventions to improve

  12. Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    K. Sharma

    Full Text Available : Background: An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open ruptured abdominal aortic aneurysm (AAA repair. Report: A 73-year-old male underwent open repair of a ruptured AAA. Five months later, computed tomography revealed filling from a lumbar vessel mimicking a Type 2 “endoleak.” The initial ultrasound showed a single pair of lumbar vessels with aneurysm sac expansion 8 weeks later. The “endoleak” and expanding sac were treated, and the 2-year surveillance demonstrated sac shrinkage. Discussion: Because endoleak is a complication after EVAR, this case provides a unique presentation of Type 2 “endoleak” physiology following open repair of a ruptured AAA. It is believed that it is necessary to expand the list of possible complications after open ruptured AAA repair to include “endoleaks.” Keywords: Endoleak: EVAR, Ruptured aneurysm, Open abdominal aortic aneurysm

  13. Infrarenal Abdominal Aortic Pseudoaneurysm: Is It a Real Emergency?

    Science.gov (United States)

    Massara, Mafalda; Prunella, Roberto; Gerardi, Pasquale; Lillo, Antonio; De Caridi, Giovanni; Serra, Raffaele; Notarstefano, Stefano; Impedovo, Giovanni

    2017-01-01

    Abdominal aortic pseudoaneurysm is a rare but life-threatening condition that occurs due to penetrating or blunt trauma. Clinical manifestations are variable, and the time interval from the initial trauma to diagnosis is variable. A prompt diagnosis and an aggressive management approach are required to avoid catastrophic complications. Possible treatment options are open surgical repair, endovascular repair, pseudoanerysmal sac thrombosis induction through direct thrombin injection, and coil embolization. Here, we present the case of a 75-year-old man affected by an infrarenal abdominal aortic pseudoaneurysm presenting with abdominal and lumbar pain for 3 days, who was successfully treated with an endograft. PMID:29515707

  14. Endovascular Exclusion of an Abdominal Aortic Aneurysm in Patients with Concomitant Abdominal Malignancy: Early Experience

    Energy Technology Data Exchange (ETDEWEB)

    Choi, You Ri; Chang, Nam Kyu [Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Shin, Hyo Hyun; Oh, Hyun Jun; Kim, Jae Kyu; Choi, Soo Jin Na; Chung, Sang Young [Chonnam National University Hospital, Gwangju (Korea, Republic of); Yim, Nam Yeol [Armed Forces Yangju Hospital, Yangju (Korea, Republic of)

    2010-08-15

    To assess the outcomes of endovascular aortic aneurysm repair (EVAR) for the treatment of an abdominal aortic aneurysm in patients undergoing curative surgical treatment for concomitant abdominal malignancy. The study included 12 patients with abdominal neoplasia and an abdominal aortic aneurysm (AAA), which was treated by surgery and stent EVAR. The neoplasm consisted of the gastric, colorectal, pancreas, prostate, and gall bladder. The follow up period was 3-21 months (mean 11.8 months). All medical records and imaging analyses were reviewed by CTA and/or color Doppler US, retrospectively. Successful endoluminal repair was accomplished in all twelve patients. The mean interval time between EVAR and surgery was 58.6 days. Small amounts of type 2 endoleaks were detected in two patients (17%). One patient developed adult respiratory distress syndrome after Whipple's operation 20 days after surgery, which led to hopeless discharge. No procedure-related mortality, morbidity, or graft-related infection was noted. Exclusion of AAA in patients with accompanying malignancy show with a relatively low procedure morbidity and mortality. Hence, endoluminal AAA repair in patients with synchronous neoplasia may allow greater flexibility in the management of an offending malignancy

  15. Endovascular Exclusion of an Abdominal Aortic Aneurysm in Patients with Concomitant Abdominal Malignancy: Early Experience

    International Nuclear Information System (INIS)

    Choi, You Ri; Chang, Nam Kyu; Shin, Hyo Hyun; Oh, Hyun Jun; Kim, Jae Kyu; Choi, Soo Jin Na; Chung, Sang Young; Yim, Nam Yeol

    2010-01-01

    To assess the outcomes of endovascular aortic aneurysm repair (EVAR) for the treatment of an abdominal aortic aneurysm in patients undergoing curative surgical treatment for concomitant abdominal malignancy. The study included 12 patients with abdominal neoplasia and an abdominal aortic aneurysm (AAA), which was treated by surgery and stent EVAR. The neoplasm consisted of the gastric, colorectal, pancreas, prostate, and gall bladder. The follow up period was 3-21 months (mean 11.8 months). All medical records and imaging analyses were reviewed by CTA and/or color Doppler US, retrospectively. Successful endoluminal repair was accomplished in all twelve patients. The mean interval time between EVAR and surgery was 58.6 days. Small amounts of type 2 endoleaks were detected in two patients (17%). One patient developed adult respiratory distress syndrome after Whipple's operation 20 days after surgery, which led to hopeless discharge. No procedure-related mortality, morbidity, or graft-related infection was noted. Exclusion of AAA in patients with accompanying malignancy show with a relatively low procedure morbidity and mortality. Hence, endoluminal AAA repair in patients with synchronous neoplasia may allow greater flexibility in the management of an offending malignancy

  16. Endovascular abdominal aortic aneurysm repair (EVAR) procedures: counterbalancing the benefits with the costs.

    Science.gov (United States)

    Paraskevas, Kosmas I; Bessias, Nikolaos; Giannoukas, Athanasios D; Mikhailidis, Dimitri P

    2010-05-01

    Endovascular abdominal aortic aneurysm (AAA) repair (EVAR) is associated with lower 30-day mortality rates compared with open repair. Despite that, there are no significant differences in mortality rates between the two procedures at 2 years. On the other hand, EVAR is associated with considerably higher costs compared with open repair. The lack of significant long-term differences between the two procedures together with the substantially higher cost of EVAR may question the appropriateness of EVAR as an alternative to open surgical repair in patients fit for surgery. With several thousands of AAA procedures performed worldwide, the employment of EVAR for the management of all AAAs irrespective of the patient's surgical risk may hold implications for several national health economies. The lower perioperative mortality and morbidity rates associated with EVAR should thus be counterbalanced against the considerable costs of these procedures.

  17. Quantification of abdominal aortic deformation after EVAR

    Science.gov (United States)

    Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir

    2009-02-01

    Quantification of abdominal aortic deformation is an important requirement for the evaluation of endovascular stenting procedures and the further refinement of stent graft design. During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and, the stent graft. This deformation can affect the flow characteristics and morphology of the aorta which have been shown to be elicitors for stent graft failures and be reason for reappearance of aneurysms. We present a method for quantifying the deformation of an aneurysmatic aorta imposed by an inserted stent graft device. The outline of the procedure includes initial rigid alignment of the two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. This is accomplished by preprocessing and remodeling of the pre- and postoperative aortic shapes before performing a non-rigid registration. We further narrow the resulting displacement fields to only include local non-rigid deformation and therefore, eliminate all remaining global rigid transformations. Finally, deformations for specified locations can be calculated from the resulting displacement fields. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results and evaluation of the usage of deformation quantification were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.

  18. Causes and Implications of Readmission after Abdominal Aortic Aneurysm Repair

    Science.gov (United States)

    Greenblatt, David Yu; Greenberg, Caprice C.; Kind, Amy J.H.; Havlena, Jeffrey A.; Mell, Matthew W.; Nelson, Matthew T.; Smith, Maureen A.; Kent, K. Craig

    2012-01-01

    Objective To determine the frequency, causes, predictors, and consequences of 30-day readmission after abdominal aortic aneurysm (AAA) repair. Summary Background Data CMS will soon reduce total Medicare reimbursements for hospitals with higher-than-predicted 30-day readmission rates after vascular surgical procedures including AAA repair. However, causes and factors leading to readmission in this population have never before been systematically analyzed. Methods We analyzed elective AAA repairs over a two-year period from the CMS Chronic Conditions Warehouse, a 5% national sample of Medicare beneficiaries. Results 2481 patients underwent AAA repair – 1502 endovascular (EVAR) and 979 open. 30-day readmission rates were equivalent for EVAR (13.3%) and open repair (12.8%). While wound complication was the most common reason for readmission after both procedures, the relative frequency of other causes differed – e.g., bowel obstruction was common following open repair and graft complication after EVAR. In multivariate analyses, preoperative comorbidities had a modest effect on readmission; however, postoperative factors including serious complications leading to prolonged length of stay and discharge destination other than home had a profound influence on the probability of readmission. The one-year mortality in readmitted patients was 23.4% versus 4.5% in those not readmitted (preadmission is common after AAA repair. Adjusting for comorbidities, postoperative events predict readmission, suggesting that proactively preventing, detecting, and managing postoperative complications may provide an approach to decreasing readmissions, with the potential to reduce cost and possibly enhance long-term survival. PMID:22964736

  19. Experience with early postoperative feeding after abdominal aortic surgery.

    Science.gov (United States)

    Ko, Po-Jen; Hsieh, Hung-Chang; Liu, Yun-Hen; Liu, Hui-Ping

    2004-03-01

    Abdominal aortic surgery is a form of major vascular surgery, which traditionally involves long hospital stays and significant postoperative morbidity. Experiences with transit ileus are often encountered after the aortic surgery. Thus traditional postoperative care involves delayed oral feeding until the patients regain their normal bowel activities. This report examines the feasibility of early postoperative feeding after abdominal aortic aneurysm (AAA) open-repair. From May 2002 through May 2003, 10 consecutive patients with infrarenal AAA who underwent elective surgical open-repair by the same surgeon in our department were reviewed. All of them had been operated upon and cared for according to the early feeding postoperative care protocol, which comprised of adjuvant epidural anesthesia, postoperative patient controlled analgesia, early postoperative feeding and early rehabilitation. The postoperative recovery and length of hospital stay were reviewed and analyzed. All patients were able to sip water within 1 day postoperatively without trouble (Average; 12.4 hours postoperatively). All but one patient was put on regular diet within 3 days postoperatively (Average; 2.2 days postoperatively). The average postoperative length of stay in hospital was 5.8 days. No patient died or had major morbidity. Early postoperative feeding after open repair of abdominal aorta is safe and feasible. The postoperative recovery could be improved and the length of stay reduced by simply using adjuvant epidural anesthesia during surgery, postoperative epidural patient-controlled analgesia, early feeding, early ambulation, and early rehabilitation. The initial success of our postoperative recovery program of aortic repair was demonstrated.

  20. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    International Nuclear Information System (INIS)

    Silverberg, Daniel; Yalon, Tal; Halak, Moshe

    2015-01-01

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft

  1. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  2. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  3. The effects of preoperative cardiology consultation prior to elective abdominal aortic aneurysm repair on patient morbidity.

    Science.gov (United States)

    Boniakowski, Anna E; Davis, Frank M; Phillips, Amanda R; Robinson, Adina B; Coleman, Dawn M; Henke, Peter K

    2017-08-01

    Objectives The relationship between preoperative medical consultations and postoperative complications has not been extensively studied. Thus, we investigated the impact of preoperative consultation on postoperative morbidity following elective abdominal aortic aneurysm repair. Methods A retrospective review was conducted on 469 patients (mean age 72 years, 20% female) who underwent elective abdominal aortic aneurysm repair from June 2007 to July 2014. Data elements included detailed medical history, preoperative cardiology consultation, and postoperative complications. Primary outcomes included 30-day morbidity, consult-specific morbidity, and mortality. A bivariate probit regression model accounting for the endogeneity of binary preoperative medical consult and patient variability was estimated with a maximum likelihood function. Results Eighty patients had preoperative medical consults (85% cardiology); thus, our analysis focuses on the effect of cardiac-related preoperative consults. Hyperlipidemia, increased aneurysm size, and increased revised cardiac risk index increased likelihood of referral to cardiology preoperatively. Surgery type (endovascular versus open repair) was not significant in development of postoperative complications when controlling for revised cardiac risk index ( p = 0.295). After controlling for patient comorbidities, there was no difference in postoperative cardiac-related complications between patients who did and did not undergo cardiology consultation preoperatively ( p = 0.386). Conclusions When controlling for patient disease severity using revised cardiac risk index risk stratification, preoperative cardiology consultation is not associated with postoperative cardiac morbidity.

  4. Discrepancies in abdominal aortic aneurysm expressions and repair

    NARCIS (Netherlands)

    Hurks, R.

    2011-01-01

    Abdominal Aortic Aneurysm (AAA) disease is a growing healthcare burden. Besides theassociated cardiovascular comorbidities, the AAA itself poses a risk for the patient in two fashions. First, it could rupture, which is associated with high mortality and morbidity. This thesis focused on the second,

  5. Acute Testicular Ischemia following Endovascular Abdominal Aortic Aneurysm Repair Identified in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Nathan Finnerty

    2014-01-01

    Full Text Available Endovascular aneurysm repair (EVAR is perhaps the most widely utilized surgical procedure for patients with large abdominal aortic aneurysms. This procedure is minimally invasive and reduces inpatient hospitalization requirements. The case involves a 72-year-old male who presented to the emergency department with right testicular ischemia two days following EVAR. Given the minimal inpatient hospitalization associated with this procedure, emergency physicians are likely to encounter associated complications. Ischemic and thromboembolic events following EVAR are extremely rare but require prompt vascular surgery intervention to minimize morbidity and mortality.

  6. A prospective clinical, economic, and quality-of-life analysis comparing endovascular aneurysm repair (EVAR), open repair, and best medical treatment in high-risk patients with abdominal aortic aneurysms suitable for EVAR: the Irish patient trial.

    LENUS (Irish Health Repository)

    Hynes, Niamh

    2007-12-01

    To report the results of a trial comparing endovascular aneurysm repair (EVAR) to open repair (OR) and best medical therapy (BMT) involving high-risk patients with abdominal aortic aneurysms (AAA) suitable for EVAR.

  7. Endovascular repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Paravastu, Sharath Chandra Vikram; Jayarajasingam, Rubaraj; Cottam, Rachel; Palfreyman, Simon J; Michaels, Jonathan A; Thomas, Steven M

    2014-01-23

    An abnormal dilatation of the abdominal aorta is referred to as an abdominal aortic aneurysm (AAA). Due to the risk of rupture, surgical repair is offered electively to individuals with aneurysms greater than 5.5 cm in size. Traditionally, conventional open surgical repair (OSR) was considered the first choice approach. However, over the past two decades endovascular aneurysm repair (EVAR) has gained popularity as a treatment option. This article intends to review the role of EVAR in the management of elective AAA. To assess the effectiveness of EVAR versus conventional OSR in individuals with AAA considered fit for surgery, and EVAR versus best medical care in those considered unfit for surgery. This was determined by the effect on short, intermediate and long-term mortality, endograft related complications, re-intervention rates and major complications. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator (TSC) searched the Specialised Register (January 2013) and the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 12). The TSC also searched trial databases for details of ongoing or unpublished studies. Prospective randomised controlled trials (RCTs) comparing EVAR with OSR in individuals with AAA considered fit for surgery. and comparing EVAR with best medical care in individuals considered unfit for surgery. We excluded studies with inadequate data or using an inadequate randomisation technique. Three reviewers independently evaluated trials for appropriateness for inclusion and extracted data using pro forma designed by the Cochrane PVD Group. We assessed the quality of trials using The Cochrane Collaboration's 'Risk of bias' tool. We entered collected data in to Review Manager (version 5.2.3) for analysis. Where direct comparisons could be made, we determined odds ratios (OR). We tested studies for heterogeneity and, when present, we used a random-effects model; otherwise we used a fixed-effect model. We tabulated

  8. Provider volume and outcomes for abdominal aortic aneurysm repair, carotid endarterectomy, and lower extremity revascularization procedures.

    LENUS (Irish Health Repository)

    Killeen, Shane D

    2012-02-03

    BACKGROUND: Intuitively, vascular procedures performed by high-volume vascular subspecialists working at high-volume institutions should be associated with improved patient outcome. Although a large number of studies assess the relationship between volume and outcome, a single contemporary compilation of such studies is lacking. METHODS: A review of the English language literature was performed incorporating searches of the Medline, EMBASE, and Cochrane collaboration databases for abdominal aortic aneurysm repair (elective and emergent), carotid endarterectomy, and arterial lower limb procedures for any volume outcome relationship. Studies were included if they involved a patient cohort from 1980 onwards, were community or population based, and assessed health outcomes (mortality and morbidity) as a dependent variable and volume as an independent variable. RESULTS: We identified 74 relevant studies, and 54 were included. All showed either an inverse relationship of variable magnitude between provider volume and mortality, or no volume-outcome effect. The reduction in the risk-adjusted mortality rate (RAMR) for high-volume providers was 3% to 11% for elective abdominal aortic aneurysm (AAA) repair, 2.5 to 5% for emergent AAA repair, 0.7% to 4.7% carotid endarterectomy, and 0.3% to 0.9% for lower limb arterial bypass procedures. Subspeciality training also conferred a considerable morbidity and mortality benefit for emergent AAA repair, carotid endarterectomy, and lower limb arterial procedures. CONCLUSION: High-volume providers have significantly better outcomes for vascular procedures both in the elective and emergent setting. Subspeciality training also has a considerable impact. These data provide further evidence for the specialization of vascular services, whereby vascular procedures should generally be preformed by high-volume, speciality trained providers.

  9. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  10. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Long-term results after repair of ruptured and non-ruptured abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kuzmanović Ilija B.

    2004-01-01

    Full Text Available INTRODUCTION Abdominal aortic aneurysm can be repaired by elective procedure while asymptomatic, or immediately when it is complicated - mostly due to rupture. Treating abdominal aneurysm electively, before it becomes urgent, has medical and economical reason. Today, the first month mortality after elective operations of the abdominal aorta aneurysm is less than 3%; on the other hand, significant mortality (25%-70% has been recorded in patients operated immediately because of rupture of the abdominal aneurysm. In addition, the costs of elective surgical treatment are significantly lower. OBJECTIVE The objective of this study is to compare long-term survival of patients that underwent elective or immediate repair of abdominal aortic aneurysm (due to rupture, and to find out the factors influencing the long-term survival of these patients. MATERIAL AND METHODS Through retrospective review of prospectively collected data of the Institute for Cardiovascular Diseases of Clinical Center of Serbia, Belgrade, 56 patients that had elective surgery and 35 patients that underwent urgent operation due to rupture of abdominal aneurysm were followed up. Only the patients that survived 30 postoperative days were included in this review, and were followed up (ranging from 2 to 126 months. Electively operated patients were followed during 58.82 months on the average (range 7 to 122, and urgently operated were followed over 52.26 months (range 2 to 126. There was no significant difference of the length of postoperative follow-up between these two groups. RESULTS During this period, out of electively operated and immediately operated patients, 27 and 22 cases died, respectively. There was no significant difference (p>0,05a of long-term survival between these two groups. Obesity and early postoperative complications significantly decreased long-term survival of both electively and immediately operated patients. Graft infection, ventral hernia, aneurysm of

  12. Open Repair of Mycotic Abdominal Aortic Aneurysms With Biological Grafts

    DEFF Research Database (Denmark)

    Heinola, Ivika; Sörelius, Karl; Wyss, Thomas R

    2018-01-01

    BACKGROUND: The treatment of mycotic abdominal aortic aneurysm requires surgery and antimicrobial therapy. Since prosthetic reconstructions carry a considerable risk of reinfection, biological grafts are noteworthy alternatives. The current study evaluated the durability, infection resistance......, and midterm outcome of biological grafts in treatment of mycotic abdominal aortic aneurysm. METHODS AND RESULTS: All patients treated with biological graft in 6 countries between 2006 and 2016 were included. Primary outcome measures were 30- and 90-day survival, treatment-related mortality, and reinfection...... rate. Secondary outcome measures were overall mortality and graft patency. Fifty-six patients (46 males) with median age of 69 years (range 35-85) were included. Sixteen patients were immunocompromised (29%), 24 (43%) had concomitant infection, and 12 (21%) presented with rupture. Bacterial culture...

  13. Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years

    NARCIS (Netherlands)

    Powell, J. T.; Sweeting, M. J.; Ulug, P.; Blankensteijn, J. D.; Lederle, F. A.; Becquemin, J.-P.; Greenhalgh, R. M.; Beard, J. D.; Buxton, M. J.; Brown, L. C.; Harris, P. L.; Rose, J. D. G.; Russell, I. T.; Sculpher, M. J.; Thompson, S. G.; Lilford, R. J.; Bell, P. R. F.; Whitaker, S. C.; Poole-Wilson, The Late P. A.; Ruckley, C. V.; Campbell, W. B.; Dean, M. R. E.; Ruttley, M. S. T.; Coles, E. C.; Halliday, A.; Gibbs, S. J.; Epstein, D.; Hannon, R. J.; Johnston, L.; Bradbury, A. W.; Henderson, M. J.; Parvin, S. D.; Shepherd, D. F. C.; Mitchell, A. W.; Edwards, P. R.; Abbott, G. T.; Higman, D. J.; Vohra, A.; Ashley, S.; Robottom, C.; Wyatt, M. G.; Byrne, D.; Edwards, R.; Leiberman, D. P.; McCarter, D. H.; Taylor, P. R.; Reidy, J. F.; Wilkinson, A. R.; Ettles, D. F.; Clason, A. E.; Leen, G. L. S.; Wilson, N. V.; Downes, M.; Walker, S. R.; Lavelle, J. M.; Gough, M. J.; McPherson, S.; Scott, D. J. A.; Kessell, D. O.; Naylor, R.; Sayers, R.; Fishwick, N. G.; Gould, D. A.; Walker, M. G.; Chalmers, N. C.; Garnham, A.; Collins, M. A.; Gaines, P. A.; Ashour, M. Y.; Uberoi, R.; Braithwaite, B.; Davies, J. N.; Travis, S.; Hamilton, G.; Platts, A.; Shandall, A.; Sullivan, B. A.; Sobeh, M.; Matson, M.; Fox, A. D.; Orme, R.; Yusef, W.; Doyle, T.; Horrocks, M.; Hardman, J.; Blair, P. H. B.; Ellis, P. K.; Morris, G.; Odurny, A.; Vohra, R.; Duddy, M.; Thompson, M.; Loosemore, T. M. L.; Belli, A. M.; Morgan, R.; Adiseshiah, M.; Brookes, J. A. S.; McCollum, C. N.; Ashleigh, R.; Aukett, M.; Baker, S.; Barbe, E.; Batson, N.; Bell, J.; Blundell, J.; Boardley, D.; Boyes, S.; Brown, O.; Bryce, J.; Carmichael, M.; Chance, T.; Coleman, J.; Cosgrove, C.; Curran, G.; Dennison, T.; Devine, C.; Dewhirst, N.; Errington, B.; Farrell, H.; Fisher, C.; Fulford, P.; Gough, M.; Graham, C.; Hooper, R.; Horne, G.; Horrocks, L.; Hughes, B.; Hutchings, T.; Ireland, M.; Judge, C.; Kelly, L.; Kemp, J.; Kite, A.; Kivela, M.; Lapworth, M.; Lee, C.; Linekar, L.; Mahmood, A.; March, L.; Martin, J.; Matharu, N.; McGuigen, K.; Morris-Vincent, P.; Murray, S.; Murtagh, A.; Owen, G.; Ramoutar, V.; Rippin, C.; Rowley, J.; Sinclair, J.; Spencer, S.; Taylor, V.; Tomlinson, C.; Ward, S.; Wealleans, V.; West, J.; White, K.; Williams, J.; Wilson, L.; Grobbee, D. E.; Bak, A. A. A.; Buth, J.; Pattynama, P. M.; Verhoeven, E. L. G.; van Voorthuisen, A. E.; Balm, R.; Cuypers, P. W. M.; Prinssen, M.; van Sambeek, M. R. H. M.; Baas, A. F.; Hunink, M. G.; van Engelshoven, J. M.; Jacobs, M. J. H. M.; de Mol, B. A. J. M.; van Bockel, J. H.; Reekers, J.; Tielbeek, X.; Wisselink, W.; Boekema, N.; Heuveling, L. M.; Sikking, I.; de Bruin, J. L.; Tielbeek, A. V.; Pattynama, P.; Prins, T.; van der Ham, A. C.; van der Velden, J. J. I. M.; van Sterkenburg, S. M. M.; ten Haken, G. B.; Bruijninckx, C. M. A.; van Overhagen, H.; Tutein Nolthenius, R. P.; Hendriksz, T. R.; Teijink, J. A. W.; Odink, H. F.; de Smet, A. A. E. A.; Vroegindeweij, D.; van Loenhout, R. M. M.; Rutten, M. J.; Hamming, J. F.; Lampmann, L. E. H.; Bender, M. H. M.; Pasmans, H.; Vahl, A. C.; de Vries, C.; Mackaay, A. J. C.; van Dortmont, L. M. C.; van der Vliet, A. J.; Schultze Kool, L. J.; Boomsma, J. H. B.; van Dop, H. R.; de Mol van Otterloo, J. C. A.; de Rooij, T. P. W.; Smits, T. M.; Yilmaz, E. N.; van den Berg, F. G.; Visser, M. J. T.; van der Linden, E.; Schurink, G. W. H.; de Haan, M.; Smeets, H. J.; Stabel, P.; van Elst, F.; Poniewierski, J.; Vermassen, F. E. G.; Freischlag, J. A.; Kohler, T. R.; Latts, E.; Matsumura, J.; Padberg, F. T.; Kyriakides, T. C.; Swanson, K. M.; Guarino, P.; Peduzzi, P.; Antonelli, M.; Cushing, C.; Davis, E.; Durant, L.; Joyner, S.; Kossack, The Late A.; LeGwin, Mary; McBride, V.; O'Connor, T.; Poulton, J.; Stratton, The Late S.; Zellner, S.; Snodgrass, A. J.; Thornton, J.; Haakenson, C. M.; Stroupe, K. T.; Jonk, Y.; Hallett, J. W.; Hertzer, N.; Towne, J.; Katz, D. A.; Karrison, T.; Matts, J. P.; Marottoli, R.; Kasl, S.; Mehta, R.; Feldman, R.; Farrell, W.; Allore, H.; Perry, E.; Niederman, J.; Randall, F.; Zeman, M.; Beckwith, The Late D.; O'Leary, T. J.; Huang, G. D.; Bader, M.; Ketteler, E. R.; Kingsley, D. D.; Marek, J. M.; Massen, R. J.; Matteson, B. D.; Pitcher, J. D.; Langsfeld, M.; Corson, J. D.; Goff, J. M.; Kasirajan, K.; Paap, C.; Robertson, D. C.; Salam, A.; Veeraswamy, R.; Milner, R.; Guidot, J.; Lal, B. K.; Busuttil, S. J.; Lilly, M. P.; Braganza, M.; Ellis, K.; Patterson, M. A.; Jordan, W. D.; Whitley, D.; Taylor, S.; Passman, M.; Kerns, D.; Inman, C.; Poirier, J.; Ebaugh, J.; Raffetto, J.; Chew, D.; Lathi, S.; Owens, C.; Hickson, K.; Dosluoglu, H. H.; Eschberger, K.; Kibbe, M. R.; Baraniewski, H. M.; Endo, M.; Busman, A.; Meadows, W.; Evans, M.; Giglia, J. S.; El Sayed, H.; Reed, A. B.; Ruf, M.; Ross, S.; Jean-Claude, J. M.; Pinault, G.; Kang, P.; White, N.; Eiseman, M.; Jones, The Late R.; Timaran, C. H.; Modrall, J. G.; Welborn, M. B.; Lopez, J.; Nguyen, T.; Chacko, J. K. Y.; Granke, K.; Vouyouka, A. G.; Olgren, E.; Chand, P.; Allende, B.; Ranella, M.; Yales, C.; Whitehill, T. A.; Krupski, The Late W. C.; Nehler, M. R.; Johnson, S. P.; Jones, D. N.; Strecker, P.; Bhola, M. A.; Shortell, C. K.; Gray, J. L.; Lawson, J. H.; McCann, R.; Sebastian, M. W.; Kistler Tetterton, J.; Blackwell, C.; Prinzo, P. A.; Lee, N.; Cerveira, J. J.; Zickler, R. W.; Hauck, K. A.; Berceli, S. A.; Lee, W. A.; Ozaki, C. K.; Nelson, P. R.; Irwin, A. S.; Baum, R.; Aulivola, B.; Rodriguez, H.; Littooy, F. N.; Greisler, H.; O'Sullivan, M. T.; Kougias, P.; Lin, P. H.; Bush, R. L.; Guinn, G.; Bechara, C.; Cagiannos, C.; Pisimisis, G.; Barshes, N.; Pillack, S.; Guillory, B.; Cikrit, D.; Lalka, S. G.; Lemmon, G.; Nachreiner, R.; Rusomaroff, M.; O'Brien, E.; Cullen, J. J.; Hoballah, J.; Sharp, W. J.; McCandless, J. L.; Beach, V.; Minion, D.; Schwarcz, T. H.; Kimbrough, J.; Ashe, L.; Rockich, A.; Warner-Carpenter, J.; Moursi, M.; Eidt, J. F.; Brock, S.; Bianchi, C.; Bishop, V.; Gordon, I. L.; Fujitani, R.; Kubaska, S. M.; Behdad, M.; Azadegan, R.; Ma Agas, C.; Zalecki, K.; Hoch, J. R.; Carr, S. C.; Acher, C.; Schwarze, M.; Tefera, G.; Mell, M.; Dunlap, B.; Rieder, J.; Stuart, J. M.; Weiman, D. S.; Abul-Khoudoud, O.; Garrett, H. E.; Walsh, S. M.; Wilson, K. L.; Seabrook, G. R.; Cambria, R. A.; Brown, K. R.; Lewis, B. D.; Framberg, S.; Kallio, C.; Barke, R. A.; Santilli, S. M.; d'Audiffret, A. C.; Oberle, N.; Proebstle, C.; Johnson, L. L.; Jacobowitz, G. R.; Cayne, N.; Rockman, C.; Adelman, M.; Gagne, P.; Nalbandian, M.; Caropolo, L. J.; Pipinos, I. I.; Johanning, J.; Lynch, T.; DeSpiegelaere, H.; Purviance, G.; Zhou, W.; Dalman, R.; Lee, J. T.; Safadi, B.; Coogan, S. M.; Wren, S. M.; Bahmani, D. D.; Maples, D.; Thunen, S.; Golden, M. A.; Mitchell, M. E.; Fairman, R.; Reinhardt, S.; Wilson, M. A.; Tzeng, E.; Muluk, S.; Peterson, N. M.; Foster, M.; Edwards, J.; Moneta, G. L.; Landry, G.; Taylor, L.; Yeager, R.; Cannady, E.; Treiman, G.; Hatton-Ward, S.; Salabsky, The Late B.; Kansal, N.; Owens, E.; Estes, M.; Forbes, B. A.; Sobotta, C.; Rapp, J. H.; Reilly, L. M.; Perez, S. L.; Yan, K.; Sarkar, R.; Dwyer, S. S.; Perez, S.; Chong, K.; Hatsukami, T. S.; Glickerman, D. G.; Sobel, M.; Burdick, T. S.; Pedersen, K.; Cleary, P.; Back, M.; Bandyk, D.; Johnson, B.; Shames, M.; Reinhard, R. L.; Thomas, S. C.; Hunter, G. C.; Leon, L. R.; Westerband, A.; Guerra, R. J.; Riveros, M.; Mills, J. L.; Hughes, J. D.; Escalante, A. M.; Psalms, S. B.; Day, N. N.; Macsata, R.; Sidawy, A.; Weiswasser, J.; Arora, S.; Jasper, B. J.; Dardik, A.; Gahtan, V.; Muhs, B. E.; Sumpio, B. E.; Gusberg, R. J.; Spector, M.; Pollak, J.; Aruny, J.; Kelly, E. L.; Wong, J.; Vasilas, P.; Joncas, C.; Gelabert, H. A.; DeVirgillio, C.; Rigberg, D. A.; Cole, L.; Marzelle, J.; Sapoval, M.; Favre, J.-P.; Watelet, J.; Lermusiaux, P.; Lepage, E.; Hemery, F.; Dolbeau, G.; Hawajry, N.; Cunin, P.; Harris, P.; Stockx, L.; Chatellier, G.; Mialhe, C.; Fiessinger, J.-N.; Pagny, L.; Kobeiter, H.; Boissier, C.; Lacroix, P.; Ledru, F.; Pinot, J.-J.; Deux, J.-F.; Tzvetkov, B.; Duvaldestin, P.; Jourdain, C.; DAVID, V.; Enouf, D.; Ady, N.; Krimi, A.; Boudjema, N.; Jousset, Y.; Enon, B.; Blin, V.; Picquet, J.; L'Hoste, P.; Thouveny, F.; Borie, H.; Kowarski, S.; Pernes, J.-M.; Auguste, M.; Desgranges, P.; Allaire, E.; Meaulle, P.-Y.; Chaix, D.; Juliae, P.; Fabiani, J. N.; Chevalier, P.; Combes, M.; Seguin, A.; Belhomme, D.; Baque, J.; Pellerin, O.; Favre, J. P.; Barral, X.; Veyret, C.; Peillon, C.; Plissonier, D.; Thomas, P.; Clavier, E.; Martinez, R.; Bleuet, F.; C, Dupreix; Verhoye, J. P.; Langanay, T.; Heautot, J. F.; Koussa, M.; Haulon, S.; Halna, P.; Destrieux, L.; Lions, C.; Wiloteaux, S.; Beregi, J. P.; Bergeron, P.; Patra, P.; Costargent, A.; Chaillou, P.; D'Alicourt, A.; Goueffic, Y.; Cheysson, E.; Parrot, A.; Garance, P.; Demon, A.; Tyazi, A.; Pillet, J.-C.; Lescalie, F.; Tilly, G.; Steinmetz, E.; Favier, C.; Brenot, R.; Krause, D.; Cercueil, J. P.; Vahdat, O.; Sauer, M.; Soula, P.; Querian, A.; Garcia, O.; Levade, M.; Colombier, D.; Cardon, J.-M.; Joyeux, A.; Borrelly, P.; Dogas, G.; Magnan, P.-É; Branchereau, A.; Bartoli, J.-M.; Hassen-Khodja, R.; Batt, M.; Planchard, P.-F.; Bouillanne, P.-J.; Haudebourg, P.; Bayne, J.; Gouny, P.; Badra, A.; Braesco, J.; Nonent, M.; Lucas, A.; Cardon, A.; Kerdiles, Y.; Rolland, Y.; Kassab, M.; Brillu, C.; Goubault, F.; Tailboux, L.; Darrieux, H.; Briand, O.; Maillard, J.-C.; Varty, K.; Cousins, C.

    2017-01-01

    The erosion of the early mortality advantage of elective endovascular aneurysm repair (EVAR) compared with open repair of abdominal aortic aneurysm remains without a satisfactory explanation. An individual-patient data meta-analysis of four multicentre randomized trials of EVAR versus open repair

  14. Influence of diabetes mellitus on the endovascular treatment of abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Leurs, L.J.; Laheij, R.J.F.; Buth, J.

    2005-01-01

    PURPOSE: To investigate the influence of diabetes mellitus on outcome after endovascular abdominal aortic aneurysm (AAA) repair. METHODS: Of 6017 patients enrolled in the EUROSTAR registry after undergoing endovascular AAA repair between May 1994 and December 2003, 731 (12%) had diabetes mellitus

  15. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  16. Epidemiology of abdominal aortic aneurysms in a Chinese population during introduction of endovascular repair, 1994 to 2013: A retrospective observational study.

    Science.gov (United States)

    Tam, Greta; Chan, Yiu Che; Chong, Ka Chun; Lee, Kam Pui; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung

    2018-03-01

    The aim of this study was to examine changes in abdominal aortic aneurysm repair and mortality during a period when endovascular aneurysm repair (EVAR) was introduced.Open repair surgery was the mainstay of treatment for abdominal aortic aneurysm (AAA), but EVAR is increasingly utilized. Studies in the Western population have reported improved short-term or postoperative mortality and shorter length of hospital stay with EVAR. However, scant data are available in the Chinese population.We conducted a retrospective observational study using the database of the Hospital Authority, which provides public health care to most of the Hong Kong population. AAA patients admitted to public hospitals for intact repair or rupture from 1994 to 2013 were included in this study. We calculated the incidence of ruptured AAA, annual repair rates according to type of AAA and surgery, as well as death rates (operative and overall short-term). We calculated whether there were significant changes over time and compared short-term mortality between open surgery and EVAR.One thousand eight hundred eighty-five patients were admitted for intact repair and 1306 patients were admitted for AAA rupture, of whom 795 underwent rupture repair. Intact repair rates significantly increased in all age groups (7.3-37.8%, P short-term AAA-related deaths decreased by more than half (73% in 1994 to 24% in 2013, P Short-term mortality was significantly lower for EVAR than for open repair (17.2% vs 40.3%, P Short-term AAA-related deaths have declined likely due to decreased operative mortality and rupture deaths during the period of EVAR introduction and expansion.

  17. Laparotomy during endovascular repair of ruptured abdominal aortic aneurysms increases mortality.

    Science.gov (United States)

    Adkar, Shaunak S; Turley, Ryan S; Benrashid, Ehsan; Cox, Mitchell W; Mureebe, Leila; Shortell, Cynthia K

    2017-02-01

    Subset analyses from small case series suggest patients requiring laparotomy during endovascular repair of ruptured abdominal aortic aneurysms (REVAR) have worse survival than those undergoing REVAR without laparotomy. Most concomitant laparotomies are performed for abdominal compartment syndrome. This study used data from the American College of Surgeons National Surgical Quality Improvement Program to determine whether the need for laparotomy during REVAR is associated with increased mortality. Data were obtained from the 2005 to 2013 National Surgical Quality Improvement Program participant user files based on Current Procedural Terminology (American Medical Association, Chicago, Ill) and International Classification of Diseases-9 Edition coding. Patient and procedure-related characteristics and 30-day postoperative outcomes were compared using Pearson χ 2 tests for categoric variables and Wilcoxon rank sum tests for continuous variables. A backward-stepwise multivariable logistic regression model was used to identify patient- and procedure-related factors associated with increased death after REVAR. We identified 1241 patients who underwent REVAR, and 91 (7.3%) required concomitant laparotomy. The 30-day mortality was 60% in the laparotomy group and 21% in the standard REVAR group (P < .001). The major complication rate was also higher in the laparotomy group (88% vs 63%; P < .001). Multivariable analysis showed laparotomy was strongly associated with 30-day mortality (odds ratio, 5.91; 95% confidence interval, 3.62-9.62; P < .001). Laparotomy during REVAR is a commonly used technique for the management of elevated intra-abdominal pressure and abdominal compartment syndrome development. The results of this study strongly confirm findings from smaller studies that the need for laparotomy during REVAR is associated with significantly worse 30-day survival. Copyright © 2016. Published by Elsevier Inc.

  18. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  19. Resultados da cirurgia do aneurisma da aorta abdominal em pacientes jovens Outcomes after surgical repair of abdominal aortic aneurysms in young patients

    Directory of Open Access Journals (Sweden)

    Telmo P. Bonamigo

    2009-06-01

    Full Text Available CONTEXTO: A presença de aneurisma da aorta abdominal (AAA é rara em pacientes jovens. OBJETIVO: Avaliar os resultados da cirurgia do AAA em pacientes com idade BACKGROUND: Abdominal aortic aneurysms (AAA are rare in young patients. OBJECTIVE: To evaluate outcomes after AAA repair in patients aged < 50 years. METHODS: Between June 1979 and January 2008, 946 patients underwent elective repair for an infrarenal AAA performed by the first author. Of these, 13 patients (1.4% were < 50 years old at surgery. Demographic characteristics and surgical data were analyzed, as well as early and late outcomes after surgical intervention. RESULTS: Mean age was 46±3.4 years (ranging from 43 to 50 years. Most patients were men (76.9%, hypertensive (76.9% and smokers (61.5%. Perioperative morbidity and mortality rates were low (15.4% and 0%, respectively; one patient had respiratory infection and another patient had unstable angina. Median follow-up was 85.5 months, and two patients died due to ischemic cardiopathy and cerebrovascular accident during the follow-up period. CONCLUSION: AAA repair in young patients is a safe procedure, with good long-term results. In our study, there were no perioperative deaths, and a good long-term survival was observed.

  20. Jaundice as a Rare Indication for Aortic Aneurysm Repair.

    Science.gov (United States)

    Rieß, Henrik C; Tsilimparis, Nikolaos; Behrendt, Christian A; Wipper, Sabine; Debus, Eike S; Larena-Avellaneda, Axel

    2015-10-01

    Compression of adjacent anatomic structures by an abdominal aortic aneurysm (AAA) can result in a variety of symptoms. We describe the case of an 88-year-old Caucasian woman with jaundice, elevated laboratory parameters for extrahepatic and intrahepatic cholestasis, and concomitant juxtarenal AAA compressing the liver hilum. Following exclusion of other common causes for cholestasis, the patient was considered to have a symptomatic AAA. Open abdominal aortic surgery revealed a contained rupture and was repaired. Obstructive jaundice secondary to a compromising AAA is a rare condition and to the best of our knowledge has not been reported to date. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Preoperative evaluation of the abdominal aortic aneurysm using spiral CT

    International Nuclear Information System (INIS)

    Chisuwa, Hisanao; Nishimaki, Keiji; Arai, Masayuki; Honda, Haruyasu; Urata, Koichi; Miyagawa, Yusuke; Makuuchi, Masatoshi; Shimizu, Mikio; Okamoto, Kohei.

    1995-01-01

    Six patients with abdominal aortic aneurysm (AAA) were studied with three-dimensionally reconstructed CT angiography (3D-CTA) in order to evaluate its usefulness as a diagnostic tool for vascular surgery patients. Images of the intravenously contrasted abdominal aorta were obtained with spiral scan during a single breath hold. The images of the abdominal aorta and its major branches were three-dimensionally reconstructed with a shaded surface display mode. The three-dimensional image reconstruction was successful in all the six cases and performed without difficulties. Shaded surface display presented a deficit to depict the aortic wall with mural thrombus. However, multidirectional display of the abdominal aorta and its branches facilitated interpretation of the anatomical details of the lesions and planning of surgical repair. 3D-CTA is an alternative to conventional aortography for preoperative diagnosis of AAA. Moreover it was shown to be noninvasive, easy to proceed. It presented good angiographical resolution that can be used as a precise diagnostic tool in vascular surgery. (author)

  2. Multimodality Imaging Approach towards Primary Aortic Sarcomas Arising after Endovascular Abdominal Aortic Aneurysm Repair: Case Series Report

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar, E-mail: kamranm@mir.wustl.edu; Fowler, Kathryn J., E-mail: fowlerk@mir.wustl.edu; Mellnick, Vincent M., E-mail: mellnickv@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States); Sicard, Gregorio A., E-mail: sicard@wudosis.wustl.edu [Washington University School of Medicine, Department of Surgery (United States); Narra, Vamsi R., E-mail: narrav@mir.wustl.edu [Washington University School of Medicine, Mallinckrodt Institute of Radiology (United States)

    2016-06-15

    Primary aortic neoplasms are rare. Aortic sarcoma arising after endovascular aneurysm repair (EVAR) is a scarce subset of primary aortic malignancies, reports of which are infrequent in the published literature. The diagnosis of aortic sarcoma is challenging due to its non-specific clinical presentation, and the prognosis is poor due to delayed diagnosis, rapid proliferation, and propensity for metastasis. Post-EVAR, aortic sarcomas may mimic other more common aortic processes on surveillance imaging. Radiologists are rarely knowledgeable about this rare entity for which multimodality imaging and awareness are invaluable in early diagnosis. A series of three pathologically confirmed cases are presented to display the multimodality imaging features and clinical presentations of aortic sarcoma arising after EVAR.

  3. Multiple Re-entry Closures After TEVAR for Ruptured Chronic Post-dissection Thoraco-abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    R. Kinoshita

    Full Text Available Introduction: Although thoracic endovascular aortic repair (TEVAR has become a promising treatment for complicated acute type B dissection, its role in treating chronic post-dissection thoraco-abdominal aortic aneurysm (TAA is still limited owing to persistent retrograde flow into the false lumen (FL through abdominal or iliac re-entry tears. Report: A case of chronic post-dissection TAA treatment, in which a dilated descending FL ruptured into the left thorax, is described. The primary entry tear was closed by emergency TEVAR and multiple abdominal re-entries were closed by EVAR. In addition, major re-entries at the detached right renal artery and iliac bifurcation were closed using covered stents. To close re-entries as far as possible, EVAR was carried out using the chimney technique, and additional aortic extenders were placed above the coeliac artery. A few re-entries remained, but complete FL thrombosis of the rupture site was achieved. Follow-up computed tomography showed significant shrinkage of the FL. Discussion: In treating post-dissection TAA, entry closure by TEVAR is sometimes insufficient, owing to persistent retrograde flow into the FL from abdominal or iliac re-entries. Adjunctive techniques are needed to close these distal re-entries to obtain complete FL exclusion, especially in rupture cases. Recently, encouraging results of complete coverage of the thoraco-abdominal aorta with fenestrated or branched endografts have been reported; however, the widespread employment of such techniques appears to be limited owing to technical difficulties. The present method with multiple re-entry closures using off the shelf and immediately available devices is an alternative for the endovascular treatment of post-dissection TAA, especially in the emergency setting. Keywords: Aortic dissection, Ruptured aortic aneurysm, Post-dissection thoracoabdominal aortic aneurysm, Endovascular aortic repair, Reentry closure, Endovascular procedures

  4. Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report.

    Science.gov (United States)

    Dregelid, Einar Børre; Lilleng, Peer Kåre

    2016-01-01

    When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. A 78-year old man with enlargement of the entire aorta underwent open repair for a pararenal abdominal aortic aneurysm using supraceliac aortic clamping for 20min. Then the graft was clamped, the supraceliac clamp was removed, and the distal and right renal anastomoses were also completed. The patient was stable throughout the operation with only transient drop in blood pressure on reperfusion. Postoperatively the patient developed ischemia, attributable to microembolization, in legs, small intestine, gall bladder and kidneys. He underwent fasciotomy, small bowel and gall bladder resections. Intestinal absorptive function did not recover adequately and he died after 4 months. Microscopic examination of hundreds of intestinal, juxtaintestinal mesenteric, and gall bladder arteries showed a few ones containing cholesterol emboli. It is unsure whether a few occluded small arteries out of several hundred could have caused the ischemic injury alone. There had been only moderate backbleeding from aortic branches above the proximal anastomosis while it was sutured. Inadvertently, remaining air in the graft, aorta, and aortic branches may have been whipped into the pulsating blood, resulting in air microbubbles, when the aortic clamp was removed. Although both atheromatous particles and air microbubbles are well-known causes of iatrogenic microembolization, the importance of air microembolization in open repair of pararenal aortic aneurysms is not known and need to be studied. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Pierre Galvagni Silveira

    2008-01-01

    Full Text Available PURPOSE: To establish a correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter placed in the same aneurysm sac before and after its exclusion by an endoprosthesis. METHODS: Patients who underwent endovascular abdominal aortic aneurysm repair and received an EndoSureTM wireless pressure sensor implant between March 19 and December 11, 2004 were enrolled in the study. Simultaneous readings of systolic, diastolic, mean, and pulse pressure within the aneurysm sac were obtained from the catheter and the sensor, both before and after sac exclusion by the endoprosthesis (Readings 1 and 2, respectively. Intrasac pressure measurements were compared using Pearson's correlation and Student's t test. Statistical significance was set at p0.05, mean (p>0.05, and pulse (p0.05 by the sensor. CONCLUSION: The excellent agreement between intrasac pressure readings recorded by the catheter and the sensor justifies use of the latter for detection of post-exclusion abdominal aortic aneurysm pressurization.

  6. Endovascular repair of aortic disease: a venture capital perspective.

    Science.gov (United States)

    Buchanan, Lucas W; Stavropoulos, S William; Resnick, Joshua B; Solomon, Jeffrey

    2009-03-01

    Endovascular devices for the treatment of abdominal and thoracic aortic disease are poised to become the next $1 billion medical device market. A shift from open repair to endovascular repair, advances in technology, screening initiatives, and new indications are driving this growth. Although billion-dollar medical device markets are rare, this field is fraught with risk and uncertainty for startups and their venture capital investors. Technological hurdles, daunting clinical and regulatory timelines, market adoption issues, and entrenched competitors pose significant barriers to successful new venture creation. In fact, the number of aortic endografts that have failed to reach commercialization or have been pulled from the market exceeds the number of Food and Drug Administration-approved endografts in the United States. This article will shed some light on the venture capital mind-set and decision-making paradigm in the context of aortic disease.

  7. Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

    International Nuclear Information System (INIS)

    Hussain, Qasim; Maleux, Geert; Heye, Sam; Fourneau, Inge

    2008-01-01

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

  8. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    International Nuclear Information System (INIS)

    Wu, Ziheng; Xu, Liang; Qu, Lefeng; Raithel, Dieter

    2015-01-01

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC

  9. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ziheng, E-mail: wuziheng303@hotmail.com [Zhejiang University, Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine (China); Xu, Liang, E-mail: maxalive@163.com [Zhejiang University, Department of Neurosurgery, The Second Affiliated Hospital, School of Medicine (China); Qu, Lefeng, E-mail: qulefeng@gmail.com [The Second Military Medical University, Department of Vascular and Endovascular Surgery, Changzheng Hospital (China); Raithel, Dieter, E-mail: dieter.raithel@rzmail.uni-erlangen.de [Nuremberg Southern Hospital, Department of Vascular and Endovascular Surgery (Germany)

    2015-02-15

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

  10. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  11. Endovascular strategy or open repair for ruptured abdominal aortic aneurysm: one-year outcomes from the IMPROVE randomized trial

    Science.gov (United States)

    Braithwaite, Bruce; Cheshire, Nicholas J.; Greenhalgh, Roger M.; Grieve, Richard; Hassan, Tajek B.; Hinchliffe, Robert; Howell, Simon; Moore, Fionna; Nicholson, Anthony A.; Soong, Chee V.; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Heatley, Francine; Anjum, Aisha; Kalinowska, Gosia; Sweeting, Michael J.; Thompson, Simon G.; Gomes, Manuel; Grieve, Richard; Powell, Janet T.; Ashleigh, Ray; Gomes, Manuel; Greenhalgh, Roger M.; Grieve, Richard; Hinchliffe, Robert; Sweeting, Michael; Thompson, Matt M.; Thompson, Simon G.; Ulug, Pinar; Roberts, Ian; Bell, Peter R. F.; Cheetham, Anne; Stephany, Jenny; Warlow, Charles; Lamont, Peter; Moss, Jonathan; Tijssen, Jan; Braithwaite, Bruce; Nicholson, Anthony A.; Thompson, Matthew; Ashleigh, Ray; Thompson, Luke; Cheshire, Nicholas J.; Boyle, Jonathan R.; Serracino-Inglott, Ferdinand; Thompson, Matt M.; Hinchliffe, Robert J.; Bell, Rachel; Wilson, Noel; Bown, Matt; Dennis, Martin; Davis, Meryl; Ashleigh, Ray; Howell, Simon; Wyatt, Michael G.; Valenti, Domenico; Bachoo, Paul; Walker, Paul; MacSweeney, Shane; Davies, Jonathan N.; Rittoo, Dynesh; Parvin, Simon D.; Yusuf, Waquar; Nice, Colin; Chetter, Ian; Howard, Adam; Chong, Patrick; Bhat, Raj; McLain, David; Gordon, Andrew; Lane, Ian; Hobbs, Simon; Pillay, Woolagasen; Rowlands, Timothy; El-Tahir, Amin; Asquith, John; Cavanagh, Steve; Dubois, Luc; Forbes, Thomas L.; Ashworth, Emily; Baker, Sara; Barakat, Hashem; Brady, Claire; Brown, Joanne; Bufton, Christine; Chance, Tina; Chrisopoulou, Angela; Cockell, Marie; Croucher, Andrea; Dabee, Leela; Dewhirst, Nikki; Evans, Jo; Gibson, Andy; Gorst, Siobhan; Gough, Moira; Graves, Lynne; Griffin, Michelle; Hatfield, Josie; Hogg, Florence; Howard, Susannah; Hughes, Cían; Metcalfe, David; Lapworth, Michelle; Massey, Ian; Novick, Teresa; Owen, Gareth; Parr, Noala; Pintar, David; Spencer, Sarah; Thomson, Claire; Thunder, Orla; Wallace, Tom; Ward, Sue; Wealleans, Vera; Wilson, Lesley; Woods, Janet; Zheng, Ting

    2015-01-01

    Aims To report the longer term outcomes following either a strategy of endovascular repair first or open repair of ruptured abdominal aortic aneurysm, which are necessary for both patient and clinical decision-making. Methods and results This pragmatic multicentre (29 UK and 1 Canada) trial randomized 613 patients with a clinical diagnosis of ruptured aneurysm; 316 to an endovascular first strategy (if aortic morphology is suitable, open repair if not) and 297 to open repair. The principal 1-year outcome was mortality; secondary outcomes were re-interventions, hospital discharge, health-related quality-of-life (QoL) (EQ-5D), costs, Quality-Adjusted-Life-Years (QALYs), and cost-effectiveness [incremental net benefit (INB)]. At 1 year, all-cause mortality was 41.1% for the endovascular strategy group and 45.1% for the open repair group, odds ratio 0.85 [95% confidence interval (CI) 0.62, 1.17], P = 0.325, with similar re-intervention rates in each group. The endovascular strategy group and open repair groups had average total hospital stays of 17 and 26 days, respectively, P < 0.001. Patients surviving rupture had higher average EQ-5D utility scores in the endovascular strategy vs. open repair groups, mean differences 0.087 (95% CI 0.017, 0.158), 0.068 (95% CI −0.004, 0.140) at 3 and 12 months, respectively. There were indications that QALYs were higher and costs lower for the endovascular first strategy, combining to give an INB of £3877 (95% CI £253, £7408) or €4356 (95% CI €284, €8323). Conclusion An endovascular first strategy for management of ruptured aneurysms does not offer a survival benefit over 1 year but offers patients faster discharge with better QoL and is cost-effective. Clinical trial registration ISRCTN 48334791. PMID:25855369

  12. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  13. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  14. Common and uncommon CT findings in rupture and impending rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Ahmed, M.Z.; Ling, L.; Ettles, D.F.

    2013-01-01

    The rapid imaging evaluation and diagnosis of rupture and impending rupture of an abdominal aortic aneurysm (AAA) is imperative. This article describes the imaging findings of rupture, impending rupture, and other abdominal aortic abnormalities. It is important not to overlook AAA as the consequences can be life threatening. All patients who had open or endovascular repair of AAA rupture over 6 years (2008–2012) were identified from our departmental database. The computed tomography (CT) images of 99 patients were reviewed for relevant findings. The mean age of the patients was 65 years and 85% were male

  15. Contemporary management of isolated chronic infrarenal abdominal aortic dissections.

    Science.gov (United States)

    Faries, Christopher M; Tadros, Rami O; Lajos, Paul S; Vouyouka, Ageliki G; Faries, Peter L; Marin, Michael L

    2016-11-01

    The purpose of this study was to report the presentation, treatment, and follow-up of isolated infrarenal aortic dissections. A review of 37 patients with isolated infrarenal aortic dissections was performed. Computed tomography scans with intravenous administration of contrast material were examined for all patients; catheter-based angiography, magnetic resonance angiography, and duplex ultrasound were used selectively. In dissections associated with the development of abdominal aortic aneurysm (AAA), the aneurysm growth rate was determined by measuring the change in maximum aneurysm diameter over time and dividing that by the duration of observation. The majority of infrarenal abdominal aortic dissection patients were male (67.6%). Hypertension (77.1%) and hyperlipidemia (77.1%) were the most common comorbidities among these patients. Aortic atherosclerosis was present in the majority of patients (60.0%); 67.6% of dissections were discovered incidentally and were asymptomatic. The mean dissection length was 5.84 ± 4.23 cm. Concomitant AAAs were present in 48.6% of cases with an average maximum diameter of 4.38 ± 1.41 cm. The aneurysm growth rate was 1.2 mm/y. Aneurysms were significantly larger in men than in women (4.87 ± 1.31 vs 3.12 ± 0.67 cm; P = .001). Endovascular intervention was performed on 14 (37.8%) patients, open surgery was performed on 1 (2.7%) patient, and surveillance with conservative medical treatment was used for 22 (59.5%) patients. Ten patients were treated successfully with endovascular repair for progressive aneurysm expansion. At the time of intervention, the mean AAA diameter was 5.04 ± 1.39 cm. The mean growth rate for aneurysms that were intervened on was 2.3 mm/y. The mean diameter of AAAs that were not intervened on was 3.56 ± 1.04 cm. Type II endoleaks were observed in three (30%) patients who underwent endovascular repair. None of these were associated with aneurysm growth and none required reintervention. The

  16. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  17. Collected world and single center experience with endovascular treatment of ruptured abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Veith, F.J.; Lachat, M.; Mayer, D.; Malina, M.; Holst, J.; Mehta, M.; Verhoeven, E.L.; Larzon, T.; Gennai, S.; Coppi, G.; Lipsitz, E.C.; Gargiulo, N.J.; Vliet, J.A. van der; Blankensteijn, J.D.; Buth, J.; Lee, W.A.; Biasiol, G.; Deleo, G.; Kasirajan, K.; Moore, R.; Soong, C.V.; Cayne, N.S.; Farber, M.A.; Raithel, D.; Greenberg, R.K.; Sambeek, M.R. van; Brunkwall, J.S.; Rockman, C.B.; Hinchliffe, R.J.

    2009-01-01

    BACKGROUND: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. OBJECTIVE: To clarify these we examined a

  18. Collected World and Single Center Experience With Endovascular Treatment of Ruptured Abdominal Aortic Aneurysms

    NARCIS (Netherlands)

    Veith, Frank J.; Lachat, Mario; Mayer, Dieter; Malina, Martin; Holst, Jan; Mehta, Manish; Verhoeven, Eric L. G.; Larzon, Thomas; Gennai, Stefano; Coppi, Gioacchino; Lipsitz, Evan C.; Gargiulo, Nicholas J.; van der Vliet, J. Adam; Blankensteijn, Jan; Buth, Jacob; Lee, W. Anthony; Biasi, Giorgio; Deleo, Gaetano; Kasirajan, Karthikeshwar; Moore, Randy; Soong, Chee V.; Cayne, Neal S.; Farber, Mark A.; Raithel, Dieter; Greenberg, Roy K.; van Sambeek, Marc R. H. M.; Brunkwall, Jan S.; Rockman, Caron B.; Hinchliffe, Robert J.

    2009-01-01

    Background: Case and single center reports have documented the feasibility and suggested the effectiveness of endovascular aneurysm repair (EVAR) of ruptured abdominal aortic aneurysms (RAAAs), but the role and value of such treatment remain controversial. Objective: To clarify these we examined a

  19. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  20. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  1. Outcomes of endovascular aortic repair in the modern era

    DEFF Research Database (Denmark)

    Budtz-Lilly, Jacob; Wanhainen, Anders; Mani, Kevin

    2018-01-01

    Monitoring outcomes following endovascular aortic repair (EVAR) is critical. Although evidence from randomized controlled trials has solidified the role of EVAR, the analysis of outcomes and "real-world" data has uncovered limitations, improved the selection of appropriate patients, and underscored...... the importance of instructions for use. Subsequent studies demonstrated the learning curve of EVAR and gradual improvement of outcomes over time. Outcomes analyses will continue to play an important role, particularly as technological growth of endovascular therapy has enabled treatment of more complex aneurysm...... pathologies and patients. The important analyses are herein reviewed, following the development of EVAR in the treatment of intact abdominal aortic aneurysms (AAA) to ruptured AAAs, and finally to complex aneurysms, including thoracoabdominal aortic aneurysms and mycotic aneurysms. This includes an overview...

  2. Microarray analysis to identify the similarities and differences of pathogenesis between aortic occlusive disease and abdominal aortic aneurysm.

    Science.gov (United States)

    Wang, Guofu; Bi, Lechang; Wang, Gaofeng; Huang, Feilai; Lu, Mingjing; Zhu, Kai

    2018-06-01

    Objectives Expression profile of GSE57691 was analyzed to identify the similarities and differences between aortic occlusive disease and abdominal aortic aneurysm. Methods The expression profile of GSE57691 was downloaded from Gene Expression Omnibus database, including 20 small abdominal aortic aneurysm samples, 29 large abdominal aortic aneurysm samples, 9 aortic occlusive disease samples, and 10 control samples. Using the limma package in R, the differentially expressed genes were screened. Followed by enrichment analysis was performed for the differentially expressed genes using database for annotation, visualization, and integrated discovery online tool. Based on string online tool and Cytoscape software, protein-protein interaction network and module analyses were carried out. Moreover, integrated TF platform database and Cytoscape software were used for constructing transcriptional regulatory networks. Results As a result, 1757, 354, and 396 differentially expressed genes separately were identified in aortic occlusive disease, large abdominal aortic aneurysm, and small abdominal aortic aneurysm samples. UBB was significantly enriched in proteolysis related pathways with a high degree in three groups. SPARCL1 was another gene shared by these groups and regulated by NFIA, which had a high degree in transcriptional regulatory network. ACTB, a significant upregulated gene in abdominal aortic aneurysm samples, could be regulated by CLIC4, which was significantly enriched in cell motions. ACLY and NFIB were separately identified in aortic occlusive disease and small abdominal aortic aneurysm samples, and separately enriched in lipid metabolism and negative regulation of cell proliferation. Conclusions The downregulated UBB, NFIA, and SPARCL1 might play key roles in both aortic occlusive disease and abdominal aortic aneurysm, while the upregulated ACTB might only involve in abdominal aortic aneurysm. ACLY and NFIB were specifically involved in aortic occlusive

  3. Update on the prevention of death from ruptured abdominal aortic aneurysm.

    Science.gov (United States)

    Jacomelli, Jo; Summers, Lisa; Stevenson, Anne; Lees, Tim; Earnshaw, Jonothan J

    2017-09-01

    Objectives To monitor the early effect of a national population screening programme for abdominal aortic aneurysm in 65-year-old men. Setting The study used national statistics for death rates from abdominal aortic aneurysm (Office of National Statistics) and hospital admission data in England (Hospital Episode Statistics). Methods Information concerning deaths from abdominal aortic aneurysm (ruptured and non-ruptured) (1999-2014) and hospital admissions for ruptured abdominal aortic aneurysm (2000-2015) was examined. Results The absolute number of deaths from abdominal aortic aneurysm in men and women aged 65 and over has decreased by around 30% from 2001 to 2014, but as the population has increased, the relative reduction was 45.6% and 40.0%, respectively. Some 65% of all abdominal aortic aneurysm deaths are in men aged over 65; women aged 65 and over account for around 31%. Deaths from ruptured abdominal aortic aneurysm in men aged 60-74 (the screened group) appear to be declining at the same rate as in men aged 75 and over. The relative decline in admissions to hospital with ruptured abdominal aortic aneurysm may be greater in men and women aged 60-74 (which contains the screened group of men), than those older, giving the first possible evidence that abdominal aortic aneurysm screening is having an effect. Conclusion The death rate from abdominal aortic aneurysm is declining rapidly in England. There is the first evidence that screening may be contributing to this reduction.

  4. Mid-term cost-effectiveness analysis of open and endovascular repair for ruptured abdominal aortic aneurysm.

    Science.gov (United States)

    Rollins, K E; Shak, J; Ambler, G K; Tang, T Y; Hayes, P D; Boyle, J R

    2014-02-01

    Emergency endovascular repair (EVAR) for ruptured abdominal aortic aneurysm (rAAA) may have lower operative mortality rates than open surgical repair. Concerns remain that the early survival benefit after EVAR for rAAA may be offset by late reinterventions. The aim of this study was to compare reintervention rates and cost-effectiveness of EVAR and open repair for rAAA. A retrospective analysis was undertaken of patients with rAAA undergoing EVAR or open repair over 6 years. A health economic model developed for the cost-effectiveness of elective EVAR was used in the emergency setting. Sixty-two patients (mean age 77·9 years) underwent EVAR and 85 (mean age 75·9 years) had open repair of rAAA. Median follow-up was 42 and 39 months respectively. There was no significant difference in 30-day mortality rates after EVAR and open repair (18 and 26 per cent respectively; P = 0·243). Reintervention rates were also similar (32 and 31 per cent; P = 0·701). The mean cost per patient was €26,725 for EVAR and €30,297 for open repair, and the cost per life-year gained was €7906 and €9933 respectively (P = 0·561). Open repair had greater initial costs: longer procedural times (217 versus 178·5 min; P < 0·001) and intensive care stay (5·0 versus 1·0 days; P = 0·015). Conversely, EVAR had greater reintervention (€156,939 versus €35,335; P = 0·001) and surveillance (P < 0·001) costs. There was no significant difference in reintervention rates after EVAR or open repair for rAAA. EVAR was as cost-effective at mid-term follow-up. The increased procedural costs of open repair are not outweighed by greater surveillance and reintervention costs after EVAR. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  5. Outcome after open surgery repair in endovascular-suitable patients with ruptured abdominal aortic aneurysms.

    Science.gov (United States)

    Krenzien, Felix; Matia, Ivan; Wiltberger, Georg; Hau, Hans-Michael; Freitas, Bruno; Moche, Michael; Schmelzle, Moritz; Jonas, Sven; Fellmer, Peter T

    2013-11-01

    Endovascular aneurysm repair (EVAR) has been suggested in several studies to be superior to open surgery repair (OSR) for the treatment of ruptured abdominal aortic aneurysms (rAAAs), but this finding might be affected by selection bias based on aneurysm morphology and patient characteristics. We tested rAAA anatomy according to EVAR suitability in patients undergoing OSR to assess the impact on mortality. This retrospective analysis reports on 83 patients with rAAAs treated between November 2002 and July 2013. Pre-operative computed tomography (CT) scans were evaluated based on EVAR suitability and were determined by blinded independent reviewers. CT scans were lacking due to acquisition in an external institution with no availability (n = 9) or solely ultrasound evaluations (n = 8). In addition patient characteristics and outcomes were assessed. All patients who underwent OSR and who had available preoperative CT scans were included in the study (n = 66). In summary, 42 % of the patients (28/66; 95 % confidence interval [CI], 30.5 - 54.4) were considered eligible for EVAR according to pre-operative CT scans and 58 % of the patients (38/66; 95 % CI, 45.6 - 69.5) were categorized as unsuitable for endovascular repair. Patients suitable for EVAR had a significantly lower prevalence of in-hospital deaths (25 % [7/28]; 95 % CI, 9 - 41) in contrast to patients unsuitable for EVAR (53 % [20/38]; 95 % CI, 36.8 - 68.5; p = 0.02). EVAR-suitable patients had a highly significant mortality reduction undergoing OSR. Thus, the present study proposes that EVAR suitability is a positive predictor for survival after open repair of rAAA.

  6. Abdominal aortic feminism.

    Science.gov (United States)

    Mortimer, Alice Emily

    2014-11-14

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. 2014 BMJ Publishing Group Ltd.

  7. The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm (AAA)

    NARCIS (Netherlands)

    Speelman, L.; Schurink, G.W.H.; Bosboom, E.M.H.; Buth, J.; Breeuwer, M.; Vosse, van de F.N.; Jacobs, M.J.H.M.

    2010-01-01

    Objectives: In the decision for surgical repair of abdominal aortic aneurysms (AAAs), the maximum diameter is the main factor. Several studies have concluded that the diameter may not be reliable as rupture risk criterion for the individual patient and wall stress was found to have a higher

  8. Three-dimensional finite volume modelling of blood flow in simulated angular neck abdominal aortic aneurysm

    Science.gov (United States)

    Algabri, Y. A.; Rookkapan, S.; Chatpun, S.

    2017-09-01

    An abdominal aortic aneurysm (AAA) is considered a deadly cardiovascular disease that defined as a focal dilation of blood artery. The healthy aorta size is between 15 and 24 mm based on gender, bodyweight, and age. When the diameter increased to 30 mm or more, the rupture can occur if it is kept growing or untreated. Moreover, the proximal angular neck of aneurysm is categorized as a significant morphological feature with prime harmful effects on endovascular aneurysm repair (EVAR). Flow pattern in pathological vessel can influence the vascular intervention. The aim of this study is to investigate the blood flow behaviours in angular neck abdominal aortic aneurysm with simulated geometry based on patient’s information using computational fluid dynamics (CFD). The 3D angular neck AAA models have been designed by using SolidWorks Software. Consequently, CFD tools are used for simulating these 3D models of angular neck AAA in ANSYS FLUENT Software. Eventually, based on the results, we summarized that the CFD techniques have shown high performance in explaining and investigating the flow patterns for angular neck abdominal aortic aneurysm.

  9. Melatonin reduces cardiac morbidity and markers of myocardial ischemia after elective abdominal aortic aneurism repair

    DEFF Research Database (Denmark)

    Gögenür, Ismail; Kücükakin, Bülent; Panduro Jensen, Leif

    2014-01-01

    The aim was to examine the effect of perioperative melatonin treatment on clinical cardiac morbidity and markers of myocardial ischemia in patients undergoing elective surgery for abdominal aortic aneurism. Reperfusion injury results in increased cardiac morbidity in patients undergoing surgery...... for abdominal aortic aneurisms (AAA). A randomized, placebo-controlled, clinical trial including patients undergoing surgery for AAA was performed. The patients received by infusion over a 2-hr period either, 50 mg melatonin or placebo intra-operatively, and 10 mg melatonin or placebo orally, the first three...... by Holter monitoring. A total of 26 patients received melatonin, while 24 received placebo. A significant reduction in cardiac morbidity was seen in the melatonin-treated patients compared with those given placebo [4% versus 29% (P = 0.02)]. Five patients (19%) who received melatonin had increased Tp...

  10. A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Torlai, Fabiola Goda; Meirelles, Gustavo S. Portes; Miranda Junior, Fausto; Fonseca, Jose Honorio A.P. da; Ajzen, Sergio; D'Ippolito, Giuseppe

    2006-01-01

    Objective: to propose a model to standardize computed tomography reports on abdominal aortic aneurysms. Materials and methods: interviews were carried out with members of the Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9). Results: the most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms were: maximum diameter of proximal aortic neck, proximal aortic neck length to lower renal arteries, shape of proximal aortic neck, maximum diameter of the aneurysm and diameter of the common iliac arteries. These data allowed the development of a proposal for a model to standardize computed tomography reports. Conclusion: a model for standardized tomographic analysis of abdominal aortic aneurysms has met vascular surgeons' needs for following-up patients and planning their treatment. (author)

  11. Comparison of three contemporary risk scores for mortality following elective abdominal aortic aneurysm repair.

    Science.gov (United States)

    Grant, S W; Hickey, G L; Carlson, E D; McCollum, C N

    2014-07-01

    A number of contemporary risk prediction models for mortality following elective abdominal aortic aneurysm (AAA) repair have been developed. Before a model is used either in clinical practice or to risk-adjust surgical outcome data it is important that its performance is assessed in external validation studies. The British Aneurysm Repair (BAR) score, Medicare, and Vascular Governance North West (VGNW) models were validated using an independent prospectively collected sample of multicentre clinical audit data. Consecutive, data on 1,124 patients undergoing elective AAA repair at 17 hospitals in the north-west of England and Wales between April 2011 and March 2013 were analysed. The outcome measure was in-hospital mortality. Model calibration (observed to expected ratio with chi-square test, calibration plots, calibration intercept and slope) and discrimination (area under receiver operating characteristic curve [AUC]) were assessed in the overall cohort and procedural subgroups. The mean age of the population was 74.4 years (SD 7.7); 193 (17.2%) patients were women and the majority of patients (759, 67.5%) underwent endovascular aneurysm repair. All three models demonstrated good calibration in the overall cohort and procedural subgroups. Overall discrimination was excellent for the BAR score (AUC 0.83, 95% confidence interval [CI] 0.76-0.89), and acceptable for the Medicare and VGNW models, with AUCs of 0.78 (95% CI 0.70-0.86) and 0.75 (95% CI 0.65-0.84) respectively. Only the BAR score demonstrated good discrimination in procedural subgroups. All three models demonstrated good calibration and discrimination for the prediction of in-hospital mortality following elective AAA repair and are potentially useful. The BAR score has a number of advantages, which include being developed on the most contemporaneous data, excellent overall discrimination, and good performance in procedural subgroups. Regular model validations and recalibration will be essential. Copyright

  12. Ex vivo repair of renal artery aneurysm associated with surgical treatment of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kostić Dušan M.

    2004-01-01

    Full Text Available INTRODUCTION Renal artery aneurysms is relatively uncommon with reported incidence ranges from 0.3% to 1%. However, considering all visceral artery aneurysms the percentage of renal artery aneurysms is relatively high between 15-25%. The distal forms of renal artery aneurysms sometimes require "ex vivo" reconstruction and kidney autotransplantation. CASE REPORT A 75-year-old male presented with the right abdominal and back pain. He suffered from a long history of arterial hypertension and chronic renal failure over the last few months (urea blood = 19.8 mmol/l; creatinine = 198 mmol/l. Duplex ultrasonography showed abdominal aortic aneurysm. Subsequent translumbarangiography revealed juxtarenal abdominal aortic aneurysm associated with distal right renal artery aneurysm. The operation was performed under combined thoracic epidural analgesia and general anesthesia using transperitoneal approach. After the laparotomy, the ascending colon was mobilized and reflected medially followed by Kocher maneuver. The result was visualization of the anterior aspect of the right kidney, the collecting system, ureter as well as the right renal vein and artery with large saccular aneurysm located distally. After mobilization of the renal vessels and careful dissection of the ureter, the kidney was explanted. The operation was continued by two surgical teams. The first team performed abdominal aortic aneurysm resection and reconstruction with bifurcated Dacron graft. The second team performed ex vivo reparation of renal artery aneurysm. All time during the explantation, the kidney was perfused by Collins' solution. The saccular right renal artery aneurysm 4 cm in diameter was located at the kidney hilus at the first bifurcation. Three branches originated from the aneurysm. The aneurysm was resected completely. The longest and widest of three branches arising from the aneurysmal sac was end-to-end anastomized with 6 mm PTFE graft. After this intervention, one of

  13. Colorectal cancer associated with abdominal aortic aneurysm: results of EVAR followed by colectomy.

    Science.gov (United States)

    Illuminati, Giulio; Ceccanei, Gianluca; Pacilè, Maria A; Pizzardi, Giulia; Palumbo, Piergaspare; Vietri, Francesco

    2013-01-01

    The association of colorectal cancer and abdominal aortic aneurysm (AAA) is infrequent but poses special problems of priority of treatment under elective circumstances. The purpose of this study was to retrospectively evaluate the outcome of 16 consecutive patients undergoing endovascular aneurysm repair (EVAR) followed by colectomy. Operative mortality was nil. Operative morbidity included two transient rise of serum creatinine level and one extraperitoneal anastomotic leakage which evolved favourably with conservative treatment. EVAR allowed a very short delay of treatment of colorectal cancer after aneurysm repair, minimizing operative complications.

  14. Associated injuries, management, and outcomes of blunt abdominal aortic injury.

    Science.gov (United States)

    de Mestral, Charles; Dueck, Andrew D; Gomez, David; Haas, Barbara; Nathens, Avery B

    2012-09-01

    Blunt abdominal aortic injury (BAAI) is very rare, and current literature is limited to case series of single-center experience. Through an analysis of the National Trauma Data Bank, the largest aggregation of United States trauma registry data, our aim was to characterize the associated injury pattern, contemporary management, and in-hospital outcomes of patients with BAAI. We used a nested case-control design. The overall cohort consisted of adult patients (age ≥ 16 years) severely injured (Injury Severity Score ≥ 16) after blunt trauma who were treated at a level 1 or 2 trauma center in years 2007 to 2009. Cases were patients with BAAI and were frequency-matched by age group and mechanism to randomly selected controls at a one-to-five ratio. Multivariable matched analysis (conditional logistic regression) was used to derive adjusted measures of association between BAAI and adjacent arterial, intra-abdominal, and bony injuries. We identified 436 patients with BAAI from 180 centers. The mean Injury Severity Score was 35 ± 14, and most patients were injured in motor vehicle crashes (84%). Multivariable analysis showed injury to the thoracic aorta, renal and iliac artery, small bowel, colon, liver, pancreas, and kidney, as well as lumbar spine fractures were independently associated with BAAI. A total of 394 patients (90%) were managed nonoperatively, and 42 (10%) underwent repair. Of these 42 patients, 29 (69%) underwent endovascular repair, with 11 patients undergoing open aortic repair and two extra-anatomic bypasses. Median time from admission to repair was 1 day (interquartile range, 1-2 days). Overall mortality was 29%. A total of 271 (69%) patients managed nonoperatively survived to hospital discharge. The index of suspicion for BAAI should be raised in severely injured patients by the presence of injuries to the lumbar spine, bowel, retroperitoneal organs, and adjacent major arteries. Although endovascular repair is the most common intervention, most

  15. Administration of platelets to ruptured abdominal aortic aneurysm patients before open surgery

    DEFF Research Database (Denmark)

    Lunen, T B; Johansson, P I; Jensen, L P

    2018-01-01

    BACKGROUND: In patients undergoing open surgery for a ruptured abdominal aortic aneurysm (rAAA), survivors demonstrate a high platelet count, and proactive administration of platelets (and fresh frozen plasma) appears to influence mortality. OBJECTIVES: This trial investigated the effect of plate......BACKGROUND: In patients undergoing open surgery for a ruptured abdominal aortic aneurysm (rAAA), survivors demonstrate a high platelet count, and proactive administration of platelets (and fresh frozen plasma) appears to influence mortality. OBJECTIVES: This trial investigated the effect...... vs 39; P = 0·15) were similar in the two groups of patients. No adverse reactions to platelet administration were observed. In addition, length of stay in the intensive care unit was unaffected by intervention. CONCLUSIONS: For patients planned for open repair of a rAAA, we observed no significant...... effect of early administration of platelets with regard to post-operative complications and stay in the ICU or in hospital and also no significant effect on mortality....

  16. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  17. Trends in treatment of ruptured abdominal aortic aneurysm: impact of endovascular repair and implications for future care.

    Science.gov (United States)

    Park, Brian D; Azefor, Nchang; Huang, Chun-Chih; Ricotta, John J

    2013-04-01

    Our aim was to determine national trends in treatment of ruptured abdominal aortic aneurysm (RAAA), with specific emphasis on open surgical repair (OSR) and endovascular aneurysm repair (EVAR) and its impact on mortality and complications. Data from the Nationwide Inpatient Sample (NIS) from 2005 to 2009 were queried to identify patients older than 59 years with RAAA. Three groups were studied: nonoperative (NO), EVAR, and OSR. Chi-square analysis was used to determine the relationship between treatment type and patient demographics, clinical characteristics, and hospital type. The impact of EVAR compared with OSR on mortality and overall complications was examined using logistic regression analysis. We identified 21,206 patients with RAAA from 2005 to 2009, of which 16,558 (78.1%) underwent operative repair and 21.8% received no operative treatment. In the operative group, 12,761 (77.1%) underwent OSR and 3,796 (22.9%) underwent EVAR. Endovascular aneurysm repair was more common in teaching hospitals (29.1% vs 15.2%, p < .0001) and in urban versus rural settings. Nonoperative approach was twice as common in rural versus urban hospitals. Reduced mortality was seen in patients transferred from another institutions (31.2% vs 39.4%, p = 0.014). Logistic regression analysis demonstrated a benefit of EVAR on both complication rate (OR = 0.492; CI, 0.380-0.636) and mortality (OR=0.535; CI, 0.395-0.724). Endovascular aneurysm repair use is increasing for RAAA and is more common in urban teaching hospitals while NO therapy is more common in rural hospitals. Endovascular aneurysm repair is associated with reduced mortality and complications across all age groups. Efforts to reduce mortality from RAAA should concentrate on reducing NO and OSR in patients who are suitable for EVAR. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  19. Regional Differences in Case Mix and Peri-operative Outcome After Elective Abdominal Aortic Aneurysm Repair in the Vascunet Database.

    Science.gov (United States)

    Mani, K; Venermo, M; Beiles, B; Menyhei, G; Altreuther, M; Loftus, I; Björck, M

    2015-06-01

    National differences exist in the outcome of elective abdominal aortic aneurysm (AAA) repair. The role of case mix variation was assessed based on an international vascular registry collaboration. All elective AAA repairs with aneurysm size data in the Vascunet database in the period 2005-09 were included. AAA size and peri-operative outcome (crude and age adjusted mortality) were analysed overall and in risk cohorts, as well as per country. Glasgow Aneurysm Score (GAS) was calculated as risk score, and patients were stratified in three equal sized risk cohorts based on GAS. Predictors of peri-operative mortality were analysed with multiple regression. Missing data were handled with multiple imputation. Patients from Australia, Finland, Hungary, Norway, Sweden and the UK (n = 5,895) were analysed; mean age was 72.7 years and 54% had endovascular repair (EVAR). There were significant variations in GAS (lowest = Finland [75.7], highest = UK [79.4], p for comparison of all regions 82. Of those with a GAS >82, 8.4% of men and 20.8% of women had an AAA case selection for elective AAA repair, including variations in AAA size and patient risk profile. These differences partly explain the variations in peri-operative mortality. Further audit is warranted to assess the underlying reasons for the regional variation in case-mix. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Periprocedural and long-term outcomes of endovascular abdominal aortic aneurysm repair in cardiology practice.

    Science.gov (United States)

    Basoor, Abhijeet; Patel, Kiritkumar C; Halabi, Abdul R; Todorov, Mina; Senthilvadivel, Prashanth; Choksi, Nishit; Phan, Thanh; LaLonde, Thomas; Yamasaki, Hiroshi; DeGregorio, Michele

    2014-12-01

    Endovascular repair of abdominal aortic aneurysm (AAA) has recently been made a class I indication in the treatment of AAA. In comparison to the conventional open surgical treatment, endovascular AAA repair (EVAR) is associated with equivalent long-term morbidity and mortality rates. Vascular surgeons perform majority of EVAR. There are no reports for the long-term results of this intervention performed by interventional cardiologists. We present one of the first reports of periprocedural and long-term outcomes of EVAR performed by interventional cardiologists. Retrospective chart review on patients with attempted EVAR between September 2005 and January 2011 was performed. Included cases were all consecutive patients who had attempted EVAR by interventional cardiologists. During the study period EVAR was attempted in 170 patients, with 27% being women. The mean age was 74 years (range 52-93). The endovascular graft placement was successful in 96% (163/170) of patients. Procedure failures were more common in women (6 of 46 vs 1 of 124, P = 0.003). The 30-day mortality was 1.8 % (3 of 170). In patients with successful EVAR the mean follow-up was 30 months and mean length of hospital stay was 3.5 ± 3.2 days. Major periprocedural complications were noted in 9% patients (15 of 167). During follow-up, six patients (3.5%) required re-intervention and additional 16 patients died with no aneurysm related deaths. EVAR primarily performed by interventional cardiologists demonstrates high periprocedural and long-term success rates. A higher EVAR failure rate has been observed in women. © 2014 Wiley Periodicals, Inc.

  1. Diagnosis of mycotic abdominal aortic aneurysm using 67-gallium citrate

    International Nuclear Information System (INIS)

    Blumoff, R.L.; McCartney, W.; Jaques, P.; Johnson, G. Jr.

    1982-01-01

    Mycotic aneurysms of the abdominal aorta are uncommon, but potentially lethal problems. Clinical subtleties may suggest their presence, but in the past, definitive diagnosis has been dependent on surgical exploration or autopsy findings. A case is presented in which 67-gallium citrate abdominal scanning localized the site of sepsis in an abdominal aortic aneurysm and allowed for prompt and successful surgical therapy. This noninvasive technique is recommended as a adjunct in the diagnosis of mycotic abdominal aortic aneurysms

  2. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  3. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  4. Rupture of abdominal aortic aneurysm into sigmoid colon: A case report

    Science.gov (United States)

    Aksoy, Murat; Yanar, Hakan; Taviloglu, Korhan; Ertekin, Cemalettin; Ayalp, Kemal; Yanar, Fatih; Guloglu, Recep; Kurtoglu, Mehmet

    2006-01-01

    Primary aorto-colic fistula is rarely reported in the literature. Although infrequently encountered, it is an important complication since it is usually fatal unless detected. Primary aorto-colic fistula is a spontaneous rupture of abdominal aortic aneurysm into the lumen of the adjacent colon loop. Here we report a case of primary aorto-colic fistula in a 54-year old male. The fistulated sigmoid colon was repaired by end-to-end anastomosis. Despite inotropic support, the patient died of sepsis and multiorgan failure on the first postoperative day. PMID:17167850

  5. Anatomical Features and Early Outcomes of Endovascular Repair of Abdominal Aortic Aneurysm from a Korean Multicenter Registry.

    Science.gov (United States)

    Kwon, Hyunwook; Lee, Do Yun; Choi, Soo Jin Na; Park, Ki Hyuk; Min, Seung-Kee; Chang, Jeong-Hwan; Huh, Seung; Jeon, Yong Sun; Won, Jehwan; Byun, Seung Jae; Park, Sang Jun; Jang, Lee Chan; Kwon, Tae-Won

    2015-09-01

    To introduce a nation-based endovascular aneurysm repair (EVAR) registry in South Korea and to analyze the anatomical features and early clinical outcomes of abdominal aortic aneurysms (AAA) in patients who underwent EVAR. The Korean EVAR registry (KER) was a template-based online registry developed and established in 2009. The KER recruited 389 patients who underwent EVAR from 13 medical centers in South Korea from January 2010 to June 2010. We retrospectively reviewed the anatomic features and 30-day clinical outcomes. Initial deployment without open conversion was achieved in all cases and procedure-related 30-day mortality rate was 1.9%. Anatomic features showed the following variables: proximal aortic neck angle 48.8±25.7° (mean±standard deviation), vertical neck length 35.0±17.2 mm, aneurysmal sac diameter 57.2±14.2 mm, common iliac artery (CIA) involvement in 218 (56.3%) patients, and median right CIA length 34.9 mm. Two hundred and nineteen (56.3%) patients showed neck calcification, 98 patients (25.2%) had neck thrombus, and the inferior mesenteric arteries of 91 patients (23.4%) were occluded. Anatomical features of AAA in patients from the KER were characterized as having angulated proximal neck, tortuous iliac artery, and a higher rate of CIA involvement. Long-term follow-up and ongoing studies are required.

  6. Abdominal Aortic Dissection with Acute Mesenteric Ischemia in a Patient with Marfan Syndrome

    Directory of Open Access Journals (Sweden)

    Chii-Shyan Lay

    2006-07-01

    Full Text Available Marfan syndrome is an autosomal dominant inherited disorder of connective tissue, with various complications manifested primarily in the cardiovascular system. It potentially leads to aortic dissection and rupture, these being the major causes of death. We report a patient who complained of acute abdominal pain, which presented as acute mesenteric ischemia combined with abdominal aortic dissection. Echocardiography showed enlargement of the aortic root and mitral valve prolapse. Abdominal computed tomography scan revealed acute mesenteric ischemia due to abdominal aortic dissection. Finally, the patient underwent surgery of aortic root replacement and had a successful outcome. Therefore, we suggest that for optimal risk assessment and monitoring of patients with Marfan syndrome, both aortic stiffness and the diameter of the superior mesenteric vein compared with that of the superior mesenteric artery are useful screening methods to detect acute mesenteric ischemia secondary to abdominal aortic dissection. Early diagnosis and early treatment can decrease the high mortality rate of patients with Marfan syndrome.

  7. Survival affects decision making for fenestrated and branched endovascular aortic repair.

    Science.gov (United States)

    Beach, Jocelyn M; Rajeswaran, Jeevanantham; Parodi, F Ezequiel; Kuramochi, Yuki; Brier, Corey; Blackstone, Eugene; Eagleton, Matthew J

    2018-03-01

    Repair options for complex abdominal and thoracoabdominal aortic aneurysms (TAAAs) are evolving with increased experience and availability of less invasive endovascular techniques. Identifying risk factors for mortality after fenestrated and branched endovascular aortic repair (F/B-EVAR) could improve patient selection and facilitate decision making regarding who may benefit from prophylactic F/B-EVAR. We evaluated 1091 patients in a prospective investigational device exemption trial who underwent F/B-EVAR from August 2001 to June 2015 for complex aortic aneurysms (CAAs). Multivariable analysis of risk factors for death was performed using a nonproportional hazards model and a nonparametric analysis using random survival forest technology. Operative mortality after F/B-EVAR was low (3.7%), with high CAA-related survival at 30 day and 5 years (96.8% and 94.0%, respectively). All-cause 5-year survival, however, was 46.2% and older age, heart failure, chronic obstructive pulmonary disease, renal disease, anemia, and coagulation disorders were risk factors. Risk was highest for those undergoing type I/II TAAA repairs and those with larger aneurysms. Patients with multiple comorbidities and those undergoing type I or II TAAA repair are at greatest risk of mortality; however, in this high-risk population, F/B-EVAR offers greater survival compared with that reported for the natural history of untreated aneurysms. Operative and early mortality is lower than the best-reported open repair outcomes, even in this high-risk population, suggesting a potential benefit in extending the use of F/B-EVAR to low-to-average risk CAA patients. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. Proteins associated with the size and expansion rate of the abdominal aortic aneurysm wall as identified by proteomic analysis

    DEFF Research Database (Denmark)

    Urbonavicius, Sigitas; Lindholt, Jes S.; Delbosc, Sandrine

    2010-01-01

    Identification of biomarkers for the natural history of abdominal aortic aneurysms (AAA) holds the key to non-surgical intervention and improved selection for AAA repair. We aimed to associate the basic proteomic composition of AAA wall tissue with the expansion rate and size in patients with AAA....

  9. Chronic inflammation, immune response, and infection in abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Shi, G-P

    2006-01-01

    Abdominal aortic aneurysms (AAA) are associated with atherosclerosis, transmural degenerative processes, neovascularization, decrease in content of vascular smooth muscle cells, and a chronic infiltration, mainly located in the outer aortic wall. The chronic infiltration consists mainly of macrop......Abdominal aortic aneurysms (AAA) are associated with atherosclerosis, transmural degenerative processes, neovascularization, decrease in content of vascular smooth muscle cells, and a chronic infiltration, mainly located in the outer aortic wall. The chronic infiltration consists mainly...... matrix metalloproteases and cysteine proteases for aortic matrix remodeling. The lymphocyte activation may be mediated by microorganisms as well as autoantigens generated from vascular structural proteins, perhaps through molecular mimicry. As in autoimmune diseases, the risk of AAA is increased...

  10. The pharmacokinetics of cefazolin in patients undergoing elective & semi-elective abdominal aortic aneurysm open repair surgery

    Directory of Open Access Journals (Sweden)

    Roberts Michael S

    2011-02-01

    Full Text Available Abstract Background Surgical site infections are common, so effective antibiotic concentrations at the sites of infection are required. Surgery can lead to physiological changes influencing the pharmacokinetics of antibiotics. The aim of the study is to evaluate contemporary peri-operative prophylactic dosing of cefazolin by determining plasma and subcutaneous interstitial fluid concentrations in patients undergoing elective of semi-elective abdominal aortic aneurysm (AAA open repair surgery. Methods/Design This is an observational pharmacokinetic study of patients undergoing AAA open repair surgery at the Royal Brisbane and Women's Hospital. All patients will be administered 2-g cefazolin by intravenous injection within 30-minutes of the procedure. Participants will have samples from blood and urine, collected at different intervals. Patients will also have a microdialysis catheter inserted into subcutaneous tissue to measure interstitial fluid penetration by cefazolin. Participants will be administered indocyanine green and sodium bromide as well as have cardiac output monitoring performed and tetrapolar bioimpedance to determine physiological changes occurring during surgery. Analysis of samples will be performed using validated liquid chromatography tandem mass-spectrometry. Pharmacokinetic analysis will be performed using non-linear mixed effects modeling to determine individual and population pharmacokinetic parameters and the effect of peri-operative physiological changes on cefazolin disposition. Discussion The study will describe cefazolin levels in plasma and the interstitial fluid of tissues during AAA open repair surgery. The effect of physiological changes to the patient mediated by surgery will also be determined. The results of this study will guide clinicians and pharmacists to effectively dose cefazolin in order to maximize the concentration of antibiotics in the tissues which are the most common site of surgical site infections.

  11. Comparative clinical effectiveness and cost effectiveness of endovascular strategy v open repair for ruptured abdominal aortic aneurysm: three year results of the IMPROVE randomised trial.

    Science.gov (United States)

    2017-11-14

    Objective  To assess the three year clinical outcomes and cost effectiveness of a strategy of endovascular repair (if aortic morphology is suitable, open repair if not) versus open repair for patients with suspected ruptured abdominal aortic aneurysm. Design  Randomised controlled trial. Setting  30 vascular centres (29 in UK, one in Canada), 2009-16. Participants  613 eligible patients (480 men) with a clinical diagnosis of ruptured aneurysm, of whom 502 underwent emergency repair for rupture. Interventions  316 patients were randomised to an endovascular strategy (275 with confirmed rupture) and 297 to open repair (261 with confirmed rupture). Main outcome measures  Mortality, with reinterventions after aneurysm repair, quality of life, and hospital costs to three years as secondary measures. Results  The maximum follow-up for mortality was 7.1 years, with two patients in each group lost to follow-up by three years. After similar mortality by 90 days, in the mid-term (three months to three years) there were fewer deaths in the endovascular than the open repair group (hazard ratio 0.57, 95% confidence interval 0.36 to 0.90), leading to lower mortality at three years (48% v 56%), but by seven years mortality was about 60% in each group (hazard ratio 0.92, 0.75 to 1.13). Results for the 502 patients with repaired ruptures were more pronounced: three year mortality was lower in the endovascular strategy group (42% v 54%; odds ratio 0.62, 0.43 to 0.88), but after seven years there was no clear difference between the groups (hazard ratio 0.86, 0.68 to 1.08). Reintervention rates up to three years were not significantly different between the randomised groups (hazard ratio 1.02, 0.79 to 1.32); the initial rapid rate of reinterventions was followed by a much slower mid-term reintervention rate in both groups. The early higher average quality of life in the endovascular strategy versus open repair group, coupled with the lower mortality at three years, led to a

  12. Hybrid aortic repair with antegrade supra-aortic and renovisceral debranching from ascending aorta.

    Science.gov (United States)

    Del Castro-Madrazo, José Antonio; Rivas-Domínguez, Margarita; Fernández-Prendes, Carlota; Zanabili Al-Sibbai, Amer; Llaneza-Coto, José Manuel; Alonso-Pérez, Manuel

    2017-05-01

    Aortic dissection is a life threatening condition. Hybrid repair has been described for the treatment of complex aortic pathology such as thoracoabdominal aortic aneurysms (TAAA) and type A and B dissections, although open and total endovascular repair are also possible. Open surgery is still associated with substantial perioperative morbi-mortality rates, thus less invasive techniques such as endovascular repair and hybrid procedures can achieve good results in centers with experience. We present the case of a patient with a chronic type B dissection and TAAA degeneration that was treated in a single stage hybrid procedure with antegrade supra-aortic and renovisceral debranching from the ascending aorta and TEVAR. At three-year follow up, the patient is free of intervention-related complications.

  13. Outcomes and Prognostic Factors of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Jung, Hye Doo; Lee, Yun Young; Lee, Seung Jin; Yim, Nam Yeol; Kim, Jae Kyu; Choi, Soo Jin Na; Jung, Sang Young; Chang, Nam Kyu; Lim, Jae Hoon

    2012-01-01

    To evaluate the outcomes and find the prognostic factors of endovascular abdominal aortic aneurysm repair (EVAR) in patients with hostile neck anatomy of the abdominal aorta. This study was performed on 100 patients with abdominal aneurysm who were treated with EVAR between March 2006 and December 2010. We divided the patients into two groups: good neck anatomy (GNA), and hostile neck anatomy (HNA) and then compared the primary success rate and the incidence rate of complications with EVAR between the two groups. Our aim was to determine the factors related to the complications of EVAR among HNA types. There were no significant differences of primary success rate and incidence rate of complications between the two groups. Among the types of HNA, the short neck angle [odd ratio (OR), 4.23; 95% confidence interval (CI), 1.21-18.70; p = 0.023] and large neck angle (OR, 2.58; 95% CI, 0.15-11.85; p = 0.031) showed a low primary success rate. The short neck angle (OR, 2.32; 95% CI, 1.18-12.29; p = 0.002) and large neck angle (OR, 4.67; 95% CI, 0.14-19.07; p = 0.032) showed a high incidence rate of early type 1 complication. In the case of the large neck angle (OR, 3.78; 95% CI, 0.96-20.80; p = 0.047), the large neck thrombus (OR, 2.23; 95% CI, 0.24-7.12; p = 0.035) and large neck calcification (OR, 2.50; 95% CI, 0.08-18.37; p 0.043) showed a high incidence rate of complications within a year. The results suggest that patients with hostile neck anatomy can be treated with EVAR successfully, although there was a higher incidence of complications in patients with a short neck length, severe neck angulation, circumferential thrombosis, and calcified proximal neck.

  14. Open Abdomen Therapy with Vacuum and Mesh Mediated Fascial Traction After Aortic Repair: an International Multicentre Study.

    Science.gov (United States)

    Acosta, Stefan; Seternes, Arne; Venermo, Maarit; Vikatmaa, Leena; Sörelius, Karl; Wanhainen, Anders; Svensson, Mats; Djavani, Khatereh; Björck, Martin

    2017-12-01

    Open abdomen therapy may be necessary to prevent or treat abdominal compartment syndrome (ACS). The aim of the study was to analyse the primary delayed fascial closure (PDFC) rate and complications after open abdomen therapy with vacuum and mesh mediated fascial traction (VACM) after aortic repair and to compare outcomes between those treated with open abdomen after primary versus secondary operation. This was a retrospective cohort, multicentre study in Sweden, Finland, and Norway, including consecutive patients treated with open abdomen and VACM after aortic repair at six vascular centres in 2006-2015. The primary endpoint was PDFC rate. Among 191 patients, 155 were men. The median age was 71 years (IQR 66-76). Ruptured abdominal aortic aneurysm (RAAA) occurred in 69.1%. Endovascular/hybrid and open repairs were performed in 49 and 142 patients, respectively. The indications for open abdomen were inability to close the abdomen (62%) at primary operation and ACS (80%) at secondary operation. Duration of open abdomen was 11 days (IQR 7-16) in 157 patients alive at open abdomen termination. The PDFC rate was 91.8%. Open abdomen initiated at primary (N=103), compared with secondary operation (N=88), was associated with less severe initial open abdomen status (p=.006), less intestinal ischaemia (p=.002), shorter duration of open abdomen (p=.007), and less renal replacement therapy (RRT, popen abdomen initiated at primary versus secondary operation. VACM was associated with a high PDFC rate after prolonged open abdomen therapy following aortic repair. Patient outcomes seemed better when open abdomen was initiated at primary, compared with secondary operation but a selection effect is possible. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  15. PCA-induced respiratory depression simulating stroke following endoluminal repair of abdominal aortic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Javed

    2007-07-01

    Full Text Available Abstract Aim To report a case of severe respiratory depression with PCA fentanyl use simulating stroke in a patient who underwent routine elective endoluminal graft repair for abdominal aortic aneurysm (AAA Case presentation A 78-year-old obese lady underwent routine endoluminal graft repair for AAA that was progressively increasing in size. Following an uneventful operation postoperative analgesia was managed with a patient-controlled analgesia (PCA device with fentanyl. On the morning following operation the patient was found to be unusually drowsy and unresponsive to stimuli. Her GCS level was 11 with plantars upgoing bilaterally. A provisional diagnosis of stroke was made. Urgent transfer to a high-dependency unit (HDU was arranged and she was given ventilatory support with a BiPap device. CT was performed and found to be normal. Arterial blood gas (ABG analysis showed respiratory acidosis with PaCO2 81 mmHg, PaO2 140 mmHg, pH 7.17 and base excess -2 mmol/l. A total dose of 600 mcg of fentanyl was self-administered in the 16 hours following emergence from general anaesthesia. Naloxone was given with good effect. There was an increase in the creatinine level from 90 μmol/L preoperatively to 167 μmol/L on the first postoperative day. The patient remained on BiPap for two days that resulted in marked improvement in gas exchange. Recovery was complete.

  16. Proteomic identification of differentially expressed proteins in aortic wall of patients with ruptured and nonruptured abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Urbonavicius, Sigitas; Lindholt, Jes S.; Vorum, Henrik

    2009-01-01

    To compare the basic proteomic composition of abdominal aortic aneurysm (AAA) wall tissue in patients with nonruptured and ruptured aneurysms.......To compare the basic proteomic composition of abdominal aortic aneurysm (AAA) wall tissue in patients with nonruptured and ruptured aneurysms....

  17. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound

    DEFF Research Database (Denmark)

    Ghulam, Q. M.; Bredahl, K. K.; Lönn, L.

    2017-01-01

    Objectives Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared...... with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. Design This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. Material and methods In total, 179 patients with small infrarenal AAAs (diameter 30–55 mm) were enrolled......L) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. Conclusion In this cohort of small AAAs, 40% of patients with a stable...

  18. Selective Aortic Arch and Root Replacement in Repair of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Fleischman, Fernando; Elsayed, Ramsey S; Cohen, Robbin G; Tatum, James M; Kumar, S Ram; Kazerouni, Kayvan; Mack, Wendy J; Barr, Mark L; Cunningham, Mark J; Hackmann, Amy E; Baker, Craig J; Starnes, Vaughn A; Bowdish, Michael E

    2018-02-01

    Controversy exists regarding the optimal extent of repair for type A aortic dissection. Our approach is to replace the ascending aorta, and only replace the aortic root or arch when intimal tears are present in those areas. We examined intermediate outcomes with this approach to acute type A aortic dissection repair. Between March 2005 and October 2016, 195 patients underwent repair of acute type A aortic dissection. Repair was categorized by site of proximal and distal anastomosis and extent of repair. Mean follow-up was 31.0 ± 30.9 months. Kaplan-Meier analysis was used to assess survival. Multiple variable Cox proportional hazards modeling was utilized to identify factors associated with overall mortality. Overall survival was 85.1%, 83.9%, 79.1%, and 74.4% at 6, 12, 36, and 60 months, respectively. Eight patients required reintervention. The cumulative incidence of aortic reintervention at 1 year with death as a competing outcome was 3.95%. Multiple variable regression analysis identified factors such as age, preoperative renal failure, concomitant thoracic endograft, postoperative myocardial infarction and sepsis, and need for extracorporeal membrane oxygenation as predictive of overall mortality. Neither proximal or distal extent of repair, nor need for reintervention affected overall survival (proximal: hazard ratio 1.63, 95% confidence interval: 0.75 to 3.51, p = 0.22; distal: hazard ratio 1.12, 95% confidence interval: 0.43 to 2.97, p = 0.81; reintervention: hazard ratio 0.03, 95% confidence interval: 0.002 to 0.490, p < 0.01). A selective approach to root and arch repair in acute type A aortic dissection is safe. If aortic reintervention is needed, survival does not appear to be affected. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Wall stress analysis of abdominal aortic aneurysms using 3D ultrasound

    NARCIS (Netherlands)

    Kok, A. M.; Nguyen, V.L.; Speelman, L.; Schurink, G.W.H.; van de Vosse, F.N.; Lopata, R.G.P.

    2014-01-01

    Wall stress analysis of abdominal aortic aneurysms is a novel tool that has proven high potential to improve risk stratification of abdominal aortic aneurysms (AAAs). Wall stress analysis is based on computed tomography (CT) and magnetic resonance imaging, however, 3D ultrasound (US) has not been

  20. Suprarenal Abdominal Aortic Coarctation Diagnosed During Pregnancy

    Directory of Open Access Journals (Sweden)

    Sh Hajsadeghi

    2010-12-01

    Full Text Available Coarctation of the abdominal aorta is an extremely rare vascular defect inwhich congenital or acquired etiologies have been described. This case concernsa 30-year-old pregnant woman with 15-years history of uncontrolled hypertensionand lower limb claudication presented with worsened hypertension during herfirst pregnancy. Magnetic resonance angiography study of aorta revealed astenosis in abdominal aorta about 12mm from the origin of celiac axisaccompanied by left sided aortic arch and right aberrant subclavian artery. Thiscase highlights the importance of a throughout physical examination in patientspresented with hypertension and it emphasizes considering the coarctation of theabdominal aorta during the diagnostic workup of hypertension, especially inyoung patients. In such cases magnetic resonance angiography of the aorta is auseful tool to reach a definitive diagnosis especially in pregnant women.Also to our knowledge, this patient is the first one found to have aortic archmalformation combined with an abdominal coarctation.

  1. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Endovascular Therapy of Ruptured Abdominal Aortic Aneurysm: Mid- and Long-Term Results

    International Nuclear Information System (INIS)

    Kubin, Klaus; Sodeck, Gottfried H.; Teufelsbauer, H.; Nowatschka, Bernd; Kretschmer, Georg; Lammer, Johannes; Schoder, Maria

    2008-01-01

    As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 ± 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2-48 days), and the median hospital stay was 16 days (range, 9-210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient's general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures

  4. How to manage a case of aymptomatic thoraco-abdominal aortic aneurysm with occluded mesenteric arteries

    Directory of Open Access Journals (Sweden)

    Abhisekh Mohanty

    2015-12-01

    Full Text Available We report a unique case of a 57-year-old male having a suprarenal thoraco-abdominal aortic aneurysm which is extending till the origin of superior mesenteric artery (SMA. The origins of celiac artery and SMA were totally occluded and filled retrogradely through dense collateral vessels arising from the inferior mesenteric artery. Surprisingly, the patient was not having any symptoms related to mesenteric ischemia. We decided to use a conventional aortic aneurysm stent graft to repair it without revascularizing the occluded mesenteric arteries. After 1 month, CT aortogram was repeated which revealed a well-apposed stent graft with no endoleaks. He did not have any clinical signs and symptoms attributable to mesenteric ischemia.

  5. Abdominal Aortic Emergencies.

    Science.gov (United States)

    Lech, Christie; Swaminathan, Anand

    2017-11-01

    This article discusses abdominal aortic emergencies. There is a common thread of risk factors and causes of these diseases, including age, male gender, hypertension, dyslipidemia, and connective tissue disorders. The most common presenting symptom of these disorders is pain, usually in the chest, flank, abdomen, or back. Computed tomography scan is the gold standard for diagnosis of pathologic conditions of the aorta in the hemodynamically stable patient. Treatment consists of a combination of blood pressure and heart rate control and, in many cases, emergent surgical intervention. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  7. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  8. Outcome and survival of patients aged 75 years and older compared to younger patients after ruptured abdominal aortic aneurysm repair: do the results justify the effort?

    DEFF Research Database (Denmark)

    Shahidi, S; Schroeder, T Veith; Carstensen, M.

    2009-01-01

    We evaluated early mortality (preoperative variables that may be predictive of 30-day mortality in elderly patients compared to younger patients after emergency open repair of ruptured abdominal aortic aneurysm (RAAA). The survey is a retrospective analysis based...... patients compared to the younger group. Between the survivors of the two groups, there were no significant differences in the total length of stay (LOS) and the LOS in the intensive care unit. Advanced age (>or=75) and the combination of this advanced age and serum creatinine of >or=0.150 mmol/L were...... the only significant (p preoperative risk factors in our single-center study. However, we believe that treatment for RAAA can be justified in elderly patients. In our experience, surgical open repair has been life-saving in 33% of patients aged 75 years and older, at a relatively low price for each...

  9. Natural history of abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Perko, M J; Schroeder, T V; Olsen, P S

    1993-01-01

    During a 10-year period in which 735 patients presented with abdominal aortic aneurysms to our clinic, 63 were not offered operative treatment. The primary reason for choosing conservative treatment was concomitant diseases that increased the risk of operation. After 2 years of followup, half...

  10. Primary congenital abdominal aortic aneurysm: a case report with perinatal serial follow-up imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im; Lee, Whal; Chung, Jin Wook; Park, Jae Hyung [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea); Kim, Sang Joon [Seoul National University College of Medicine, Seoul National University Hospital, Department of Surgery, Seoul (Korea); Seo, Jeong-Wook [Seoul National University College of Medicine, Seoul National University Hospital, Department of Pathology, Seoul (Korea)

    2008-11-15

    Abdominal aortic aneurysms in neonates and infants are rare and are usually associated with infection, vasculitis, connective tissue disorder, or iatrogenic trauma such as umbilical catheterization. An idiopathic congenital abdominal aortic aneurysm is the least common category and there are few descriptions of the imaging features. We present the antenatal and postnatal imaging findings of an idiopathic congenital abdominal aortic aneurysm including the findings on US, MRI and CT. (orig.)

  11. Marfan's syndrome presenting with abdominal aortic aneurysm: A ...

    African Journals Online (AJOL)

    We present the case of a 16-year old student with Marfan's syndrome and abdominal aortic aneurysm who presented with a diagnostic conundrum. He presented with a three months history of progressive painful left upper abdominal mass and back pain. It became severe in the last two weeks before presentation and was ...

  12. Survival following ruptured abdominal aortic aneurysm before and during the IMPROVE Trial: a single-centre series.

    Science.gov (United States)

    Ambler, G K; Twine, C P; Shak, J; Rollins, K E; Varty, K; Coughlin, P A; Hayes, P D; Boyle, J R

    2014-04-01

    The first large-scale randomised trial (Immediate Management of the Patient with Rupture: Open Versus Endovascular repair [IMPROVE]) for endovascular repair of ruptured abdominal aortic aneurysm (rEVAR) has recently finished recruiting patients. The aim of this study was to examine the impact on survival after rEVAR when the IMPROVE protocol was initiated in a high volume abdominal aortic aneurysm (AAA) centre previously performing rEVAR. One hundred and sixty-nine patients requiring emergency infrarenal AAA repair from January 2006 to April 2013 were included. Eighty-four patients were treated before (38 rEVAR, 46 open) and 85 (31 rEVAR, 54 open) were treated during the trial period. A retrospective analysis was performed. Before the trial, there was a significant survival benefit for rEVAR over open repair (90-day mortality 13% vs. 30%, p = .04, difference remained significant up to 2 years postoperatively). This survival benefit was lost after starting randomisation (90-day mortality 35% vs. 33%, p = .93). There was an increase in overall 30-day mortality from 15% to 31% (p = .02), while there was no change for open repair (p = .438). There was a significant decrease in general anaesthetic use (p = .002) for patients treated during the trial. Randomised patients had shorter hospital and intensive treatment unit stays (p = .006 and p = .03 respectively). The change in survival seen during the IMROVE trial highlights the need for randomised rather than cohort data to eliminate selection bias. These results from a single centre reinforce those recently reported in IMPROVE. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  14. Identification of peroxiredoxin-1 as a novel biomarker of abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Martinez-Pinna, Roxana; Ramos-Mozo, Priscila; Madrigal-Matute, Julio

    2011-01-01

    In the search of novel biomarkers of abdominal aortic aneurysm (AAA) progression, proteins released by intraluminal thrombus (ILT) were analyzed by a differential proteomic approach.......In the search of novel biomarkers of abdominal aortic aneurysm (AAA) progression, proteins released by intraluminal thrombus (ILT) were analyzed by a differential proteomic approach....

  15. Rupture of an Abdominal Aortic Aneurysm in a Young Man with Marfan Syndrome.

    Science.gov (United States)

    Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren; Nielsen, Dorte Guldbrand; Andersen, Niels Holmark

    2018-04-01

    Abdominal aortic aneurysms (AAAs) are very rare in Marfan syndrome. We present a case with a young nonsmoking and normotensive male with Marfan syndrome, who developed an infrarenal AAA that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock. The patient had acute aortic surgery and survived. Five months before this incident, the patient had uneventful elective aortic root replacement (ad modum David) due to an enlarged aortic root. At that time, his abdominal aorta was assessed with a routine ultrasound scan that showed a normal-sized abdominal aorta. This documents that the aneurysm had evolved very rapidly despite young age and absence of risk factors. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  17. Mechanisms of recurrent aortic regurgitation after aortic valve repair: predictive value of intraoperative transesophageal echocardiography.

    Science.gov (United States)

    le Polain de Waroux, Jean-Benoît; Pouleur, Anne-Catherine; Robert, Annie; Pasquet, Agnès; Gerber, Bernhard L; Noirhomme, Philippe; El Khoury, Gébrine; Vanoverschelde, Jean-Louis J

    2009-08-01

    The aim of the present study was to examine the intraoperative echocardiographic features associated with recurrent severe aortic regurgitation (AR) after an aortic valve repair surgery. Surgical valve repair for AR has significant advantages over valve replacement, but little is known about the predictors and mechanisms of its failure. We blindly reviewed all clinical, pre-operative, intraoperative, and follow-up transesophageal echocardiographic data of 186 consecutive patients who underwent valve repair for AR during a 10-year period and in whom intraoperative and follow-up echo data were available. After a median follow-up duration of 18 months, 41 patients had recurrent 3+ AR, 23 patients presented with residual 1+ to 2+ AR, and 122 had no or trivial AR. In patients with recurrent 3+ AR, the cause of recurrent AR was the rupture of a pericardial patch in 3 patients, a residual cusp prolapse in 26 patients, a restrictive cusp motion in 9 patients, an aortic dissection in 2 patients, and an infective endocarditis in 1 patient. Pre-operatively, all 3 groups were similar for aortic root dimensions and prevalence of bicuspid valve (overall 37%). Patients with recurrent AR were more likely to display Marfan syndrome or type 3 dysfunction pre-operatively. At the opposite end, patients with continent AR repair at follow-up were more likely to have type 2 dysfunction pre-operatively. After cardiopulmonary bypass, a shorter coaptation length, the degree of cusp billowing, a lower level of coaptation (relative to the annulus), a larger diameter of the aortic annulus and the sino-tubular junction, the presence of a residual AR, and the width of its vena contracta were associated with the presence of AR at follow-up. Multivariate Cox analysis identified a shorter coaptation length (odds ratio [OR]: 0.8, p = 0.05), a coaptation occurring below the level of the aortic annulus (OR: 7.9, p < 0.01), a larger aortic annulus (OR: 1.2, p = 0.01), and residual aortic regurgitation

  18. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    Science.gov (United States)

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  19. Critical role of mast cell chymase in mouse abdominal aortic aneurysm formation

    DEFF Research Database (Denmark)

    Sun, J; Zhang, J; Lindholt, Jes S.

    2009-01-01

    Mast cell chymase may participate in the pathogenesis of human abdominal aortic aneurysm (AAA), yet a direct contribution of this serine protease to AAA formation remains unknown.......Mast cell chymase may participate in the pathogenesis of human abdominal aortic aneurysm (AAA), yet a direct contribution of this serine protease to AAA formation remains unknown....

  20. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  1. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  2. Assessing the potential risk of rupture of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Khan, S.; Verma, V.; Verma, S.; Polzer, S.; Jha, S.

    2015-01-01

    Abdominal aortic aneurysms (AAAs) involve complex interplays between inflammatory and biomechanical factors that can be elucidated with anatomical and functional imaging. Although AAA size has been well-established in the literature to correlate with risk of rupture (and subsequent need for vascular intervention), there are other less-well-known characteristics about AAAs that also contribute to higher risk of rupture. This review focuses on biomechanical, radiological, and epidemiological characteristics of AAAs that are associated with higher rupture risk. For clinicians, knowing and considering a wide variety of risk factors in addition to AAA size is important to initiate early and proper intervention for AAA repair. Although there is no official quantitative risk score of AAA rupture risk that takes other non-size-related variables into account, if clinicians are aware of these other parameters, it is hoped that intervention can be appropriately performed for higher-risk AAAs that have not met the size-threshold for elective repair

  3. Outcomes of Endovascular Abdominal Aortic Aneurysm Repair in Patients with Hostile Neck Anatomy

    International Nuclear Information System (INIS)

    Choke, Edward; Munneke, Graham; Morgan, Robert; Belli, Anna-Maria; Loftus, Ian; McFarland, Robert; Loosemore, Thomas; Thompson, Matthew M.

    2006-01-01

    Purpose. The principal anatomic contraindication to endovascular aneurysm repair (EVR) is an unfavorable proximal aortic neck. With increasing experience, a greater proportion of patients with unfavorable neck anatomy are being offered EVR. This study aimed to evaluate outcomes in patients with challenging proximal aortic neck anatomy. Methods. Prospectively collected data from 147 consecutive patients who underwent EVR between December 1997 and April 2005 were supplemented with a retrospective review of medical records and radiological images. Unfavorable anatomic features were defined as neck diameter >28 mm, angulation >60 deg., circumferential thrombus >50%, and length 30 days) (p = 0.57), distal type I endoleak (p = 0.40), type III endoleak (p 0.51), secondary interventions (p = 1.0), aneurysm sac expansion (p = 0.44), or 30 day mortality (p = 0.70). The good neck group had a significantly increased incidence of type II endoleak (p = 0.023). By multivariate analysis, the incidence of intraoperative adjunctive procedures was significantly increased in the presence of severe angulation (p = 0.041, OR 3.08, 95% CI 1.05-9.04). Conclusion. Patients with severely hostile proximal aortic neck anatomy may be treated with EVR, although severely angulated necks require additional intraoperative procedures. Early outcomes are encouraging and suggest that indications for EVR may be expanded to include patients with hostile neck anatomy

  4. Rupture of an abdominal aortic aneurysm in a young man with Marfan Syndrome

    DEFF Research Database (Denmark)

    Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren

    2018-01-01

    Abdominal aortic aneurysms are very rare in Marfan syndrome. We present a case with a young non-smoking and normotensive male with Marfan syndrome, who developed an infrarenal abdominal aortic aneurysm that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock...

  5. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  6. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  7. Screening for abdominal aortic aneurysms Rastreamento de aneurismas da aorta abdominal

    Directory of Open Access Journals (Sweden)

    Telmo Pedro Bonamigo

    2003-01-01

    Full Text Available OBJECTIVE AND METHODS: Screening for abdominal aortic aneurysms may be useful to decrease mortality related to rupture. We conducted a study to assess the prevalence of abdominal aortic aneurysms in southern Brazil and to define risk factors associated with high prevalence of this disorder. The screening was conducted using abdominal ultrasound. Three groups were studied: Group 1 - cardiology clinic patients; Group 2 - individuals with severe ischemic disease and previous coronary surgery, or important lesions on cardiac catheterism; Group 3 - individuals without cardiac disease selected from the general population. All individuals were male and older than 54 years of age. The ultrasonographic diagnosis of aneurysm was based on an anteroposterior abdominal aorta diameter of 3 cm, or on an abdominal aorta diameter 0.5 cm greater than that of the supra-renal aorta. RESULTS: A total of 2.281 people were screened for abdominal aortic aneurysms in all groups: Group 1 - 768 individuals, Group 2 - 501 individuals, and Group 3 - 1012 individuals. The prevalence of aneurysms was 4.3%, 6.8% and 1.7%, respectively. Age and cigarette smoking were significantly associated with increased prevalence of aneurysms, as was the diagnosis of peripheral artery disease. DISCUSSION: We concluded that screening may be an important tool to prevent the mortality associated with abdominal aortic aneurysms surgery. Additionally, the cost of screening can be decreased if only individuals presenting significant risk factors, such as coronary and peripheral artery disease, smokers and relatives of aneurysm patients, are examined.OBJETIVO E MÉTODOS: O rastreamento de aneurisma da aorta abdominal infra-renal é importante pois pode diminuir a mortalidade relacionada à ruptura. Realizamos um estudo para definir a prevalência desses aneurismas em diversos segmentos da população em nossa região do Brasil. O rastreamento foi realizado utilizando-se a ecografia de abdômen. Tr

  8. Aortocaval fistula – rare complication of ruptured abdominal aortic ...

    African Journals Online (AJOL)

    in 0.2 - 1.3% of patients with degenerative aortic aneurysms. 1 This paper describes the presentation and successful management of a patient with such an ACF. We wish to highlight the need to maintain a high index of suspicion for this condition in patients with abdominal aortic aneurysms (AAA), particularly if they present ...

  9. Repair-oriented classification of aortic insufficiency: impact on surgical techniques and clinical outcomes.

    Science.gov (United States)

    Boodhwani, Munir; de Kerchove, Laurent; Glineur, David; Poncelet, Alain; Rubay, Jean; Astarci, Parla; Verhelst, Robert; Noirhomme, Philippe; El Khoury, Gébrine

    2009-02-01

    Valve repair for aortic insufficiency requires a tailored surgical approach determined by the leaflet and aortic disease. Over the past decade, we have developed a functional classification of AI, which guides repair strategy and can predict outcome. In this study, we analyze our experience with a systematic approach to aortic valve repair. From 1996 to 2007, 264 patients underwent elective aortic valve repair for aortic insufficiency (mean age - 54 +/- 16 years; 79% male). AV was tricuspid in 171 patients bicuspid in 90 and quadricuspid in 3. One hundred fifty three patients had type I dysfunction (aortic dilatation), 134 had type II (cusp prolapse), and 40 had type III (restrictive). Thirty six percent (96/264) of the patients had more than one identified mechanism. In-hospital mortality was 1.1% (3/264). Six patients experienced early repair failure; 3 underwent re-repair. Functional classification predicted the necessary repair techniques in 82-100% of patients, with adjunctive techniques being employed in up to 35% of patients. Mid-term follow up (median [interquartile range]: 47 [29-73] months) revealed a late mortality rate of 4.2% (11/261, 10 cardiac). Five year overall survival was 95 +/- 3%. Ten patients underwent aortic valve reoperation (1 re-repair). Freedoms from recurrent Al (>2+) and from AV reoperation at 5 years was 88 +/- 3% and 92 +/- 4% respectively and patients with type I (82 +/- 9%; 93 +/- 5%) or II (95 +/- 5%; 94 +/- 6%) had better outcomes compared to type III (76 +/- 17%; 84 +/- 13%). Aortic valve repair is an acceptable therapeutic option for patients with aortic insufficiency. This functional classification allows a systematic approach to the repair of Al and can help to predict the surgical techniques required as well as the durability of repair. Restrictive cusp motion (type III), due to fibrosis or calcification, is an important predictor for recurrent Al following AV repair.

  10. A rare cause of lomber pain: diopatic abdominal aortic pseudoaneurysm

    International Nuclear Information System (INIS)

    Colak, F.; Saglam, M.; Sahin, M.; Bozlar, U.

    2012-01-01

    Full text: Introduction: Abdominal aortic pseudoaneurysms are rare and life-threatening situations. Trauma and operative procedures are common causes of pseudoaneurysm. Abdominal pain is the most common symptom of them. They are usually detected incidentally. Objectives and tasks: We aim to present CTA findings of abdominal aortic pseudoaneurysm causes gradually increasing lomber pain in 70-year-old female patient. Physical examination also made diagnosis easy because of pulsatile mass detected. Materials and methods: Lomber MRG and endoscopic procedures were normal. Then we performed CTA to find the cause for pulsatile mass. Results: Pseudoaneurysm with approximately 6 x 7.5 cm size was compressing duodenum and not showing extravasation at the infrarenal segment of abdominal aorta detected in CTA. Pseudoaneurysm was filling from aorta through a 2 cm neck. Conclusion: Primary cause for pseudoaneurysms is traumating injuries. Initial presentation may be abdominal pain, gastrointestinal bleeding or pulsatile mass. To plan treatment and figure out pseudoaneurysm CTA is very fast and non-invasive technic

  11. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  12. The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Vammen, Sten; Juul, Søren

    1999-01-01

    the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.......the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs....

  13. Long-term decline in renal function is more significant after endovascular repair of infrarenal abdominal aortic aneurysms.

    Science.gov (United States)

    Al Adas, Ziad; Shepard, Alexander D; Nypaver, Timothy J; Weaver, Mitchell R; Maatman, Thomas; Yessayan, Lenar T; Balraj, Praveen; Kabbani, Loay S

    2018-03-20

    It is not clear whether endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) results in an increase in renal insufficiency during the long term compared with open repair (OR). We reviewed our experience with AAA repair to determine whether there was a significant difference in postoperative and long-term renal outcomes between OR and EVAR. A retrospective cohort study was conducted of all patients who underwent AAA repair between January 1993 and July 2013 at a tertiary referral hospital. Demographics, comorbidities, preoperative and postoperative laboratory values, morbidity, and mortality were collected. Patients with ruptured AAAs, preoperative hemodialysis, juxtarenal or suprarenal aneurysm origin, and no follow-up laboratory values were excluded. Preoperative, postoperative, 6-month, and yearly serum creatinine values were collected. Glomerular filtration rate (GFR) was calculated on the basis of the Chronic Kidney Disease Epidemiology Collaboration equation. Acute kidney injury (AKI) was classified using the Kidney Disease: Improving Global Outcomes guidelines. Change in GFR was defined as preoperative GFR minus the GFR at each follow-up interval. Comparison was made between EVAR and OR groups using multivariate logistics for categorical data and linear regression for continuous variables. During the study period, 763 infrarenal AAA repairs were performed at our institution; 675 repairs fit the inclusion criteria (317 ORs and 358 EVARs). Mean age was 73.9 years. Seventy-nine percent were male, 78% were hypertensive, 18% were diabetic, and 31% had preoperative renal dysfunction defined as GFR below 60 mL/min. Using a multivariate logistic model to control for all variables, OR was found to have a 1.6 times greater chance for development of immediate postoperative AKI compared with EVAR (P = .038). Hypertension and aneurysm size were independent risk factors for development of AKI (P = .012 and .022, respectively). Using a linear

  14. Thoracoabdominal aortic aneurysm repair in patients with marfan syndrome.

    Science.gov (United States)

    Mommertz, G; Sigala, F; Langer, S; Koeppel, T A; Mess, W H; Schurink, G W H; Jacobs, M J

    2008-02-01

    We assessed the surgical outcome of descending thoracic aortic aneurysm repair (DTAA) and thoracoabdominal aortic aneurym (TAAA) repair in patients with Marfan syndrome. During a six year period, 206 patients underwent DTAA and TAAA repair. In 22 patients, Marfan syndrome was confirmed. The median age was 40 years with a range between 18 and 57 years. The extend of the aneurysms included 6 DTAA (1 with total arch, 2 with distal hemi-arch), 11 type II TAAA (2 with total arch, 3 with distal hemi-arch), 4 type III and one type IV TAAA. All patients suffered from previous type A (n=6) or type B (n=16) aortic dissection and 15 already underwent aortic procedures like Bentall (n=7) and ascending aortic replacement (n=8). All patients were operated on according to the standard protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials. In patients undergoing simultaneous arch replacement (via left thoracotomy), transcranial Doppler and EEG assessed cerebral physiology during antegrade brain perfusion. In four patients circulatory arrest under moderate hypothermia was required. In-hospital mortality did not occur. Major postoperative complications like paraplegia, renal failure, stroke and myocardial infarction were not encountered. Mean pre-operative creatinine level was 125mmol/L, which peaked to a mean maximal level of 130 and returned to 92mmol/L at discharge. Median intubation time was 1.5 days (range 0.33-30 days). Other complications included bleeding requiring surgical intervention (n=1), arrhythmia (n=2), pneumonia (n=2) and respiratory distress syndrome (n=1). At a median follow-up of 38 months all patients were alive. Using CT surveillance, new or false aneurysms were not detected, except in one patient who developed a visceral patch aneurysm six years after open type II repair. Surgical repair of descending and thoracoabdominal aortic aneurysms provides excellent short- and mid-term results in

  15. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    Science.gov (United States)

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Why routine intensive care unit admission after elective open infrarenal Abdominal Aortic Aneurysm repair is no longer an evidence based practice.

    LENUS (Irish Health Repository)

    Ryan, David

    2012-01-31

    BACKGROUND: Elective open infrarenal Abdominal Aortic Aneurysm (AAA) repair is major surgery performed on high-risk patients. Routine ICU admission postoperatively is the current accepted standard of care. Few of these patients actually require a level of care that cannot be provided just as effectively in a surgical high dependency unit (HDU). Our aim was to determine, \\'can high risk patients that will require ICU admission postoperatively be reliably identified preoperatively?\\'. METHODS: A retrospective analysis of all elective open infrarenal AAA repairs in our institution over a 3-year period was performed. The Estimation of Physiological Ability and Surgical Stress (E-PASS) model was used as our risk stratification tool for predicting post-operative morbidity. Renal function was also considered as a predictor of outcome, independent of the E-PASS. RESULTS: 80% (n = 16) were admitted to ICU. Only 30% (n = 6) of the total study population necessitated intensive care. There were 9 complications in 7 patients in our study. The E-PASS comprehensive risk score (CRS)\\/Surgical stress score (SSS) were found to be significantly associated with the presence of a complication (p = 0.009)\\/(p = 0.032) respectively. Serum creatinine (p = 0.013) was similarly significantly associated with the presence of a complication. CONCLUSIONS: The E-PASS model possessing increasing external validity is an effective risk stratification tool in safely deciding the appropriate level of post-operative care for elective infrarenal AAA repairs.

  17. A quantitative approach of abdominal aortic atherosclerosis with x-ray computed tomography

    International Nuclear Information System (INIS)

    Watanabe, Hiromi; Kubota, Kazuo; Ito, Kengo; Ono, Shuichi; Matsuzawa, Taiju

    1983-01-01

    Currently epidemiologic studies of aortic atherosclerosis are most commonly done by the conventional roentgenological or pathological methods before and after death respectively. Pathological method is difficult and only possible after death. Roentgenological method is simple and useful before death, but its inability to evaluate atherosclerosis in a constant manner is serious drawback. A simple and quantitative method for epidemiological and clinical study of atherosclerosis has been needed. It this study, we examined the usefulness of Calcification Index (C.I.) caliculated from CT films for the evaluation of abdominal aortic atherosclerosis. We analysed 42 patients (32 males, 10 females). They recieved abdominal CT examination and died within a year. First, we got C.I. from their CT films. Then we got Surface Involved (S.I.) of atherosclerotic lesion from their autopsied abdominal aorta with pathological observation. The correlation coefficient between C.I. and S.I. was 0.83 (p<0.001). So we may use C.I. for the evaluation of abdominal aortic atherosclerosis. (author)

  18. Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joon Young, E-mail: pjy1331@hanmail.net; Kim, Shin Jung, E-mail: witdd2@hanmail.net; Kim, Hyoung Ook, E-mail: chaos821209@hanmail.net [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Kim, Yong Tae, E-mail: mono-111@hanmail.net [Chonnam National University Hwasun Hospital, Department of Radiology (Korea, Republic of); Lim, Nam Yeol, E-mail: apleseed@hanmail.net; Kim, Jae Kyu, E-mail: kjkrad@jnu.ac.kr [Chonnam National University Hospital, Department of Radiology (Korea, Republic of); Chung, Sang Young, E-mail: sycpvts@jnu.ac.kr; Choi, Soo Jin Na, E-mail: choisjn@jnu.ac.kr; Lee, Ho Kyun, E-mail: mhaha@hanmail.net [Chonnam National University Hospital, Department of Surgery (Korea, Republic of)

    2015-02-15

    This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

  19. The Burden of Hard Atherosclerotic Plaques Does Not Promote Endoleak Development After Endovascular Aortic Aneurysm Repair: A Risk Stratification

    International Nuclear Information System (INIS)

    Petersen, Johannes; Glodny, Bernhard

    2011-01-01

    Purpose: To objectify the influence of the atherosclerotic burden in the proximal landing zone on the development of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) using objective aortic calcium scoring (ACS). Materials and Methods: This retrospective observation study included 267 patients who received an aortic endograft between 1997 and 2010 and for whom preoperative computed tomography (CT) was available to perform ACS using the CT-based V600 method. The mean follow-up period was 2 ± 2.3 years. Results: Type I endoleaks persisted in 45 patients (16.9%), type II in 34 (12.7%), type III in 8 (3%), and type IV or V in 3 patients, respectively (1.1% each). ACS in patients with type I endoleaks was not increased: 0.029 ± 0.061 ml compared with 0.075 ± 0.1349 ml in the rest of the patients, (p > 0.05; Whitney–Mann U-Test). There were significantly better results for the indication “traumatic aortic rupture” than for the other indications (p < 0.05). In multivariate logistic regression analyses, age was an independent risk factor for the development of type I endoleaks in the thoracic aorta (Wald 9.5; p = 0.002), whereas ACS score was an independent protective factor (Wald 6.9; p = 0.009). In the abdominal aorta, neither age nor ACS influenced the development of endoleaks. Conclusion: Contrary to previous assumptions, TEVAR and EVAR can be carried out without increasing the risk of an endoleak of any type, even if there is a high atherosclerotic “hard-plaque” burden of the aorta. The results are significantly better for traumatic aortic.

  20. Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Dijkstra, Martijn L; Tielliu, Ignace F J; Meerwaldt, Robbert; Pierie, Maurice; van Brussel, Jerome; Schurink, Geert Willem H; Lardenoye, Jan-Willem; Zeebregts, Clark J

    2014-08-01

    In the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device. A prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation. Between May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%. Initial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. Abnormalities of aortic arch shape, central aortic flow dynamics, and distensibility predispose to hypertension after successful repair of aortic coarctation.

    Science.gov (United States)

    Donazzan, Luca; Crepaz, Robert; Stuefer, Josef; Stellin, Giovanni

    2014-10-01

    Systemic hypertension (HT) is a major long-term complication even after successful repair of aortic coarctation (CoA), and many factors are involved in this pathophysiology. To investigate the role of abnormalities in the aortic arch shape, central aortic flow dynamics, and distensibility in developing HT after successful repair of CoA. We selected a group of 26 normotensive patients (mean age 16.9±7.3 years, range 9-32 years) with anatomically successful repair of CoA among 140 patients regularly followed after repair of CoA and analyzed their last clinical and echocardiographic data. Bicycle exercise test and ambulatory blood pressure monitoring (ABPM) were also obtained. Mean age at surgical repair was 3.2±3.9 years (range 10 days-15 years); 12 patients underwent surgical correction during the first year of life. Repair of CoA was performed by end-to-end anastomosis (TT) in 23 patients (extended TT in 6 patients with arch hypoplasia), patch aortoplasty in 2, and subcalvian flap aortoplasty in 1. The postsurgical follow-up was 13.8±7.2 years (range 3.5-29.4 years). The shape of the aortic arch was defined by magnetic resonance imaging (MRI) on this global geometry (normal-gothic-crenel), ratio of the height-transverse diameter (A/T), percentage of residual stenosis, and growth index of the transverse arch segments. Flow mapping by phase-contrast imaging in the ascending and descending aorta was performed in order to measure the systolic waveforms and central aortic distensibility. Twenty normal age-matched patients submitted to the same MRI protocol were used as controls. Six patients were found to have a gothic and 20 a normal aortic arch shape. Patients with gothic aortic arch shape had an increased A/T ratio (0.80±0.07 vs 0.58±0.05, P135 mm Hg on ABPM were higher in the gothic than in the normal arch group. There was a correlation between nocturnal SBP, 24 hours pulse pressure on ABPM in the whole group, and different MRI variables (A/T, distensibility of

  2. Endovascular Treatment of Infrarenal Abdominal Aortic Aneurysm with Short and Angulated Neck in High-Risk Patient

    Directory of Open Access Journals (Sweden)

    Stylianos Koutsias

    2013-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA is an established alternative to open repair. However lifelong surveillance is still required to monitor endograft function and signal the need for secondary interventions (Hobo and Buth 2006. Aortic morphology, especially related to the proximal neck, often complicates the procedure or increases the risk for late device-related complications (Hobo et al. 2007 and Chisci et al. 2009. The definition of a short and angulated neck is based on length (60° (Hobo et al. 2007 and Chisci et al. 2009. A challenging neck also offers difficulties during open repairs (OR, necessitating extensive dissection with juxta- or suprarenal aortic cross-clamping. Patients with extensive aneurysmal disease typically have more comorbidities and may not tolerate extensive surgical trauma (Sarac et al. 2002. It is, therefore, unclear whether aneurysms with a challenging proximal neck should be offered EVAR or OR (Cox et al. 2006, Choke et al. 2006, Robbins et al. 2005, Sternbergh III et al. 2002, Dillavou et al. 2003, and Greenberg et al. 2003. In our case the insertion of a thoracic endograft followed by the placement of a bifurcated aortic endograft for the treatment of a very short and severely angulated neck proved to be feasible offering acceptable duration of aneurysm exclusion. This adds up to our armamentarium in the treatment of high-risk patients, and it should be considered in emergency cases when the fenestrated and branched endografts are not available.

  3. Calculating when elective abdominal aortic aneurysm repair improves survival for individual patients: development of the Aneurysm Repair Decision Aid and economic evaluation.

    Science.gov (United States)

    Grant, Stuart W; Sperrin, Matthew; Carlson, Eric; Chinai, Natasha; Ntais, Dionysios; Hamilton, Matthew; Dunn, Graham; Buchan, Iain; Davies, Linda; McCollum, Charles N

    2015-04-01

    Abdominal aortic aneurysm (AAA) repair aims to prevent premature death from AAA rupture. Elective repair is currently recommended when AAA diameter reaches 5.5 cm (men) and 5.0 cm (women). Applying population-based indications may not be appropriate for individual patient decisions, as the optimal indication is likely to differ between patients based on age and comorbidities. To develop an Aneurysm Repair Decision Aid (ARDA) to indicate when elective AAA repair optimises survival for individual patients and to assess the cost-effectiveness and associated uncertainty of elective repair at the aneurysm diameter recommended by the ARDA compared with current practice. The UK Vascular Governance North West and National Vascular Database provided individual patient data to develop predictive models for perioperative mortality and survival. Data from published literature were used to model AAA growth and risk of rupture. The cost-effectiveness analysis used data from published literature and from local and national databases. A combination of systematic review methods and clinical registries were used to provide data to populate models and inform the structure of the ARDA. Discrete event simulation (DES) was used to model the patient journey from diagnosis to death and synthesised data were used to estimate patient outcomes and costs for elective repair at alternative aneurysm diameters. Eight patient clinical scenarios (vignettes) were used as exemplars. The DES structure was validated by clinical and statistical experts. The economic evaluation estimated costs, quality-adjusted life-years (QALYs) and incremental cost-effectiveness ratios (ICERs) from the NHS, social care provider and patient perspective over a lifetime horizon. Cost-effectiveness acceptability analyses and probabilistic sensitivity analyses explored uncertainty in the data and the value for money of ARDA-based decisions. The ARDA outcome measures include perioperative mortality risk, annual risk of

  4. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  5. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  6. A case of megadolichobasilar anomaly complicated with abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Ohta, Sumio; Yamaguchi, Takenori; Ogata, Jun; Ito, Mamoru; Kikuchi, Haruhiko

    1985-01-01

    A 41 year-old hypertensive male was admitted because of progressing left hemiparesis and dysarthria. CT demonstrated hyperdense mass with partial contast enhancement, extending from the level of lower pons to that of suprasellar cistern. Reconstructed imaging of CT showed a huge mass lesion, in which a wide curvilinear hyperdensity was demonstrated by contrast enhancement. Cerebral angiography revealed markedly elongated and dilated basilar and carotid arteries. From these findings, the prepontine hyperdense mass lesion was diagnosed as megadolichobasilar anomaly with marked wall thickening. Findings of abdominal aortic angiography and abdominal CT suggested the presence of marked atherosclerosis and abdominal aortic aneurysm with mural thrombi. Six months after initial admission, neurological symptoms gradually deteriorated and CT showed dilatation of the 3rd and lateral ventricles, suggesting the development of hydrocephalus due to compression of the aqueduct by the megadolichobasilar anomaly. Magnetic resonance imaging at this time demonstrated more details of the lesion and the deformity of the brain stem, which was not detected by conventional CT. Complications of vascular anomalies other than intracranial vasculature, such as aortic aneurysm, have also been repoted. After the introduction of CT, demonstration of a long, wide, curvilinear structure with abnormal density in the prepontine region has been reported to be diagnostic for the megadolichobasilar anomaly. This patient has had hypertension for 10 years, which probably due to chronic nephritis. He had no definite findings for angitis, but had abdominal aortic aneurysm with mural thrombi. From these findings, atherosclerosis of large vessels may have played one of the roles in the pathogenesis of this anomaly in the present case. (J.P.N.)

  7. Abdominal aortic calcifications predict survival in peritoneal dialysis patients

    DEFF Research Database (Denmark)

    Mäkelä, Satu M; Asola, Markku; Hadimeri, Henrik

    2018-01-01

    BACKGROUND: Peripheral arterial disease and vascular calcifications contribute significantly to the outcome of dialysis patients. The aim of this study was to evaluate the prognostic role of severity of abdominal aortic calcifications and peripheral arterial disease on outcome of peritoneal...... dialysis (PD) patients using methods easily available in everyday clinical practice. METHODS: We enrolled 249 PD patients (mean age 61 years, 67% male) in this prospective, observational, multicenter study from 2009 to 2013. The abdominal aortic calcification score (AACS) was assessed using lateral lumbar.......9) in 17%, and high (> 1.3) in 34% of patients. Altogether 91 patients (37%) died during the median follow-up of 46 months. Only 2 patients (5%) with AACS 0 died compared with 50% of the patients with AACS ≥ 7 (p

  8. Increased galectin-3 levels are associated with abdominal aortic aneurysm progression and inhibition of galectin-3 decrease elastase-induced AAA development

    DEFF Research Database (Denmark)

    Fernandez-García, Carlos-Ernesto; Tarin, Carlos; Roldan-Montero, Raquel

    2017-01-01

    Abdominal aortic aneurysm (AAA) evolution is unpredictable. Moreover, no specific treatment exists for AAA, except surgery to prevent aortic rupture. Galectin-3 has been previously associated with CVD, but its potential role in AAA have not been addressed. Galectin-3 levels were increased in plasma...... of AAA patients (n=225) compared to controls (n=100). Moreover, galectin-3 concentrations were associated with need for surgical repair, independently of potential confounding factors. Galectin-3 mRNA and protein expression were increased in human AAA samples compared to healthy aortas. Experimental AAA...... in mice was induced by aortic elastase perfusion. Mice were treated i.v. with the galectin-3 inhibitor modified citrus pectin (MCP, 10mg/kg, every other day) or saline. Similar to humans, galectin-3 serum and aortic mRNA levels were also increased in elastase-induced AAA mice compared to control mice...

  9. Severity of chronic obstructive pulmonary disease is associated with adverse outcomes in patients undergoing elective abdominal aortic aneurysm repair.

    Science.gov (United States)

    Stone, David H; Goodney, Philip P; Kalish, Jeffrey; Schanzer, Andres; Indes, Jeffrey; Walsh, Daniel B; Cronenwett, Jack L; Nolan, Brian W

    2013-06-01

    Although chronic obstructive pulmonary disease (COPD) has been implicated as a risk factor for abdominal aortic aneurysm (AAA) rupture, its effect on surgical repair is less defined. Consequently, variation in practice persists regarding patient selection and surgical management. The purpose of this study was to analyze the effect of COPD on patients undergoing AAA repair. We reviewed a prospective regional registry of 3455 patients undergoing elective open AAA repair (OAR) and endovascular AAA repair (EVAR) from 23 centers in the Vascular Study Group of New England from 2003 to 2011. COPD was categorized as none, medical (medically treated but not oxygen [O2]-dependent), and O2-dependent. End points included in-hospital death, pulmonary complications, major postoperative adverse events (MAEs), extubation in the operating room, and 5-year survival. Survival was determined using life-table analysis based on the Social Security Death Index. Predictors of in-hospital and long-term mortality were determined by multivariate logistic regression and Cox proportional hazards analysis. During the study interval, 2043 patients underwent EVAR and 1412 patients underwent OAR with a nearly equal prevalence of COPD (35% EVAR vs 36% OAR). O2-dependent COPD (4%) was associated with significantly increased in-hospital mortality, pulmonary complications, and MAE and was also associated with significantly decreased extubation in the operating room among patients undergoing both EVAR and OAR. Five-year survival was significantly diminished among all patients undergoing AAA repair with COPD (none, 78%; medical, 72%; O2-dependent, 42%; P < .001). By multivariate analysis, O2-dependent COPD was independently associated with in-hospital mortality (odds ratio 2.02, 95% confidence interval, 1.0-4.0; P = .04) and diminished 5-year survival (hazard ratio, 3.02; 95% confidence interval, 2.2-4.1; P < .001). Patients with O2-dependent COPD undergoing AAA repair suffer increased pulmonary

  10. Natural history of abdominal aortic aneurysm with and without coexisting chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Heickendorff, Lene; Antonsen, Sebastian

    1998-01-01

    To study the relation between abdominal aortic aneurysms and chronical obstructive pulmonary disease (COPD), in particular the suggested common elastin degradation caused by elastase and smoking.......To study the relation between abdominal aortic aneurysms and chronical obstructive pulmonary disease (COPD), in particular the suggested common elastin degradation caused by elastase and smoking....

  11. Nuclear cardiac ejection fraction and cardiac index in abdominal aortic surgery

    International Nuclear Information System (INIS)

    Fiser, W.P.; Thompson, B.W.; Thompson, A.R.; Eason, C.; Read, R.C.

    1983-01-01

    Since atherosclerotic heart disease results in more than half of the perioperative deaths that follow abdominal aortic surgery, a prospective protocol was designed for preoperative evaluation and intraoperative hemodynamic monitoring. Twenty men who were prepared to undergo elective operation for aortoiliac occlusive disease (12 patients) and abdominal aortic aneurysm (eight patients) were evaluated with a cardiac scan and right heart catheterization. The night prior to operation, each patient received volume loading with crystalloid based upon ventricular performance curves. At the time of the operation, all patients were anesthetized with narcotics and nitrous oxide, and hemodynamic parameters were recorded throughout the operation. Aortic crossclamping resulted in a marked depression in CI in all patients. CI remained depressed after unclamping in the majority of patients. There were two perioperative deaths, both from myocardial infarction or failure. Both patients had ejection fractions less than 30% and initial CIs less than 2 L/M2, while the survivors' mean ejection fraction was 63% +/- 1 and their mean CI was 3.2 L/M2 +/- 0.6. The authors conclude that preoperative evaluation of ejection fraction can select those patients at a high risk of cardiac death from abdominal aortic operation. These patients should receive intensive preoperative monitoring with enhancement of ventricular performance

  12. Perioperative nursing for patients receiving endovascular therapy for ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Wei; Zhang Hongpeng; Guo Wei; Liu Xiaoping; Wei Ren

    2010-01-01

    Objective: To discuss the nursing strategy and practical measures for patients with ruptured abdominal aortic aneurysm during the perioperative period of endovascular intervention. Methods: Endovascular therapy was carried out in 34 patients with ruptured abdominal aortic aneurysm,who were encountered in our department during the period of July 1997 to September 2008. The clinical data were retrospectively analyzed and the nursing points were summarized. Results: The average hospitalization days of the 34 patients were (14 ± 5) days, the mortality rate within 30 days was 23.5% (8/34). No nursing-related complications occurred. Conclusion: A comprehensive understanding of the mechanism, development and clinical evolution of ruptured abdominal aortic aneurysm is very important for nursing care. For nursing staff, well mastering the relevant nursing technique, carefully guarding against any nursing errors and lessening patient's suffering as far as possible, all these are the task of primary importance. (authors)

  13. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  14. Induction of autoimmune abdominal aortic aneurysm in pigs

    DEFF Research Database (Denmark)

    Riber, Sara Schødt; Ali, Mulham; Bergseth, Sara Hveding

    2017-01-01

    of this study was to develop a large animal model for abdominal aortic aneurysm induction through autoimmunity by performing sheep-to-pig xenotransplantation. Methods Six pigs underwent a xenotransplantation procedure where the infrarenal porcine aorta was replaced by a decellularized sheep aorta...

  15. Two-dimensional versus three-dimensional CT angiography in analysis of anatomical suitability for stentgraft repair of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitoulias, Georgios A.; Aslanidou, Eleni A.; Papadimitriou, Dimitrios K.; Donas, Konstantinos P.; Schulte, Stefan

    2011-01-01

    Background The morphological analysis prior to endovascular abdominal aneurysm repair (EVAR) plays an important role in long-term outcomes. Post-imaging analysis of computed tomographic angiography (CTA) by three-dimensional reconstruction with central lumen line detection (CLL 3D-CTA) enables measurements to be made in orthogonal slices. This might be more precise than equal post-imaging analysis in axial slices by two-dimensional computed tomographic angiography (2D-CTA). Purpose To evaluate the intra- and interobserver variability of CLL 3D-CTA and 2D-CTA post-imaging analysis methods and the agreement between them in pre-EVAR suitability analysis of patients with abdominal aortic aneurysm (AAA). Material and Methods Anonymized CTA data-sets from 70 patients with AAA were analyzed retrospectively. Length measurements included proximal and distal aortic neck lengths and total distance from the lower renal artery to the higher iliac bifurcation. Width measurements included proximal and distal neck diameters, maximum AAA diameter and common iliac diameters just above the iliac bifurcations. The measurements were performed in random order by two vascular surgeons, twice per method with 1-month interval between readings. In the CLL 3D-CTA method we used semi-automated CLL detection by software and manual measurements on CTA slices perpendicular to CLL. The equal measurements in 2D-CTA were performed manually on axial CTA slices using a DICOM viewer workstation. The intra- and interobserver variability, as well as the agreement between the two methods were assessed by Bland-Altman test and bivariate correlation analysis. Results The intraobserver variability was significantly higher in 2D-CTA measurements for both readers. The interobserver variability was significant in 2D-CTA measurements of proximal neck dimensions while the agreement in CLL 3D-CTA analysis between the two readers was excellent in all studied parameters. The agreement between the two suitability

  16. Abdominal aortic aneurysm development in men following a "normal" aortic ultrasound scan.

    Science.gov (United States)

    Hafez, H; Druce, P S; Ashton, H A

    2008-11-01

    To determine predictors related to abdominal aortic aneurysm (AAA) development following a "normal" aortic ultrasound scan. Over a 23-year period, 22 961 men participated in an AAA screening programme. Maximum aortic diameter of less than 30 mm was deemed "normal". 4308 of these "normal" individuals were later re-scanned at intervals for research purposes. AAA prevalence was 4.4% at initial scanning. In those with a normal scan, 46 patients subsequently presented with AAAs incidentally detected and 120 (2.8%) had AAAs identified as part of the ongoing surveillance. The median initial aortic size of these 166 men was 25 mm (range 15-29 mm). Over the follow-up period, there have been 24 (14%) AAA-related deaths, 24 patients underwent successful AAA surgery and 36 died of unrelated causes. In those with an initial aortic diameter of <25 mm who later developed an AAA, the odds ratio for AAA-related mortality was 2 (95% CI 1-4.1, p=0.03, x(2)). AAAs can develop following an initial "normal" scan and men with an aortic diameters of 25-29 mm appear to be at greater risk. Surveillance for this sub-group may further reduce the incidence of undiagnosed AAA and AAA-related mortality.

  17. Statin use and rupture of abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Wemmelund, H; Høgh, A; Hundborg, H H

    2014-01-01

    BACKGROUND: Ruptured abdominal aortic aneurysm (rAAA) is associated with high mortality. Research suggests that statins may reduce abdominal aortic aneurysm (AAA) growth and improve rAAA outcomes. However, the clinical impact of statins remains uncertain in relation to both the risk and prognosis...... of rAAA. METHODS: This nationwide, population-based, combined case-control and follow-up study included all patients (aged at least 50 years) with a first-time hospital admission for rAAA and 1:1 matched AAA controls without rupture in Denmark from 1996 to 2008. Individual-level data on preadmission...... drug use, co-morbidities, socioeconomic markers, healthcare contacts and death were obtained from Danish nationwide registries. RESULTS: The study included 3584 cases and 3584 matched controls. Current statin use was registered for 418 patients with rAAA (11.7 per cent) and 539 AAA controls (15.0 per...

  18. [Albert Einstein and his abdominal aortic aneurysm].

    Science.gov (United States)

    Cervantes Castro, Jorge

    2011-01-01

    The interesting case of Albert Einstein's abdominal aortic aneurysm is presented. He was operated on at age 69 and, finding that the large aneurysm could not be removed, the surgeon elected to wrap it with cellophane to prevent its growth. However, seven years later the aneurysm ruptured and caused the death of the famous scientist.

  19. Predominance of Abdominal Visceral Adipose Tissue Reflects the Presence of Aortic Valve Calcification.

    Science.gov (United States)

    Oikawa, Masayoshi; Owada, Takashi; Yamauchi, Hiroyuki; Misaka, Tomofumi; Machii, Hirofumi; Yamaki, Takayoshi; Sugimoto, Koichi; Kunii, Hiroyuki; Nakazato, Kazuhiko; Suzuki, Hitoshi; Saitoh, Shu-Ichi; Takeishi, Yasuchika

    2016-01-01

    Background. Aortic valve calcification (AVC) is a common feature of aging and is related to coronary artery disease. Although abdominal visceral adipose tissue (VAT) plays fundamental roles in coronary artery disease, the relationship between abdominal VAT and AVC is not fully understood. Methods. We investigated 259 patients who underwent cardiac and abdominal computed tomography (CT). AVC was defined as calcified lesion on the aortic valve by CT. %abdominal VAT was calculated as abdominal VAT area/total adipose tissue area. Results. AVC was detected in 75 patients, and these patients showed higher %abdominal VAT (44% versus 38%, p AVC. When the cutoff value of %abdominal VAT was set at 40.9%, the area under the curve to diagnose AVC was 0.626. Multivariable logistic regression analysis showed that age (OR 1.120, 95% CI 1.078-1.168, p AVC. The net reclassification improvement value for detecting AVC was increased when %abdominal VAT was added to the model: 0.5093 (95% CI 0.2489-0.7697, p AVC.

  20. Complete ten-year follow-up after endovascular abdominal aortic aneurysm repair: Survival and causes of death

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Nolz, Richard; Teufelsbauer, Harald; Kretschmer, Georg; Prusa, Alexander M.; Funovics, Martin; Lammer, Johannes; Schoder, Maria

    2012-01-01

    Purpose: To analyze the hazard and causes of death after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms during a complete ten year follow-up. Methods: This is a retrospective clinical study of 130 consecutive patients undergoing EVAR between 1995 and 1998. One-hundred twenty-one patients (93.1%) were treated with first-generation stentgrafts and nine patients (6.9%) received second-generation devices. All patients completed a follow-up of at least 10 years, unless death occurred before then. Time and causes of death were provided by the Austrian central register of deaths. Results: The median follow-up was 7.6 years, and the 130 patients had 968.5 person-years of follow-up. The ten-year mortality rate was 62.3%. Cardiovascular events were the most frequent causes of death, with a 3.9 incidence rate per 100 person-years. Cancer death and death due to other causes occurred in 2.1 and 1.8 cases per 100 person-years, respectively. Lethal late aneurysm rupture happened in 4.6% (n = 6), which corresponds to an annual incidence rate of 0.6 per 100 person-years. All of those patients had been treated with first-generation devices. Conclusions: Cardiovascular events were the most frequent cause of death after EVAR, followed by malignancy and other diseases. The risk of dying from secondary rupture was clearly lower than that of death due to other reasons during ten years after EVAR, even in patients with first-generation stentgrafts.

  1. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  2. Durability of Aortic Valve Cusp Repair With and Without Annular Support.

    Science.gov (United States)

    Zeeshan, Ahmad; Idrees, Jay J; Johnston, Douglas R; Rajeswaran, Jeevanantham; Roselli, Eric E; Soltesz, Edward G; Gillinov, A Marc; Griffin, Brian; Grimm, Richard; Hammer, Donald F; Pettersson, Gösta B; Blackstone, Eugene H; Sabik, Joseph F; Svensson, Lars G

    2018-03-01

    To determine the value of aortic valve repair rather than replacement for valve dysfunction, we assessed late outcomes of various repair techniques in the contemporary era. From January 2001 to January 2011, aortic valve repair was planned in 1,124 patients. Techniques involved commissural figure-of-8 suspension sutures (n = 63 [6.2%]), cusp repair with commissuroplasty (n = 481 [48%]), debridement (n = 174 [17%]), free-margin plication (n = 271 [27%]) or resection (n = 75) or both, or annulus repair with resuspension (n = 230 [23%]), root reimplantation (n = 252 [25%]), or remodeling (n = 35 [3.5%]). Planned repair was aborted for replacement in 115 patients (10%); risk factors included greater severity of aortic regurgitation (AR; p = 0.0002) and valve calcification (p < 0.0001). In-hospital outcomes for the remaining 1,009 patients included death (12 [1.2%]), stroke (13 [1.3%]), and reoperation for valve dysfunction (14 [1.4%]). Freedom from aortic valve reoperation at 1, 5, and 10 years was 97%, 93%, and 90%, respectively. Figure-of-8 suspension sutures, valve resuspension, and root repair and replacement were least likely to require reoperation; cusp repair with commissural sutures, plication, and commissuroplasty was most likely (p < 0.05). Survival at 1, 5, and 10 years was 96%, 92%, and 83%. Immediate postoperative AR grade was none-mild (94%), moderate (5%), and severe (1%). At 10 years after repair, AR grade was none (20%), mild (33%), moderate (26%), and severe (21%). Patients undergoing root procedures were less likely to have higher-grade postoperative AR (p < 0.0001). Valve repair is effective and durable for treating aortic valve dysfunction. Greater severity of AR preoperatively is associated with higher likelihood of repair failure. Commissural figure-of-8 suspension sutures and repair with annular support have the best long-term durability. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  3. Familial Abdominal Aortic Aneurysm : Clinical Features and Genetics

    NARCIS (Netherlands)

    K.M. van de Luijtgaarden (Koen)

    2016-01-01

    markdownabstractAbstract Cardiovascular disease is the most important cause of death in the world and encompasses occlusive as well as aneurysmal disease. The most common aneurysm in humans is the abdominal aortic aneurysm (AAA). The question is why the aorta dilates in aneurysmal disease and

  4. Thoracic Endovascular Aortic Repair (TEVAR) in Proximal (Type A) Aortic Dissection: Ready for a Broader Application?

    OpenAIRE

    Nienaber, Christoph A.; Sakalihasan, Natzi; Clough, Rachel E.; Aboukoura, Mohamed; Mancuso, Enrico; Yeh, James S.M.; Defraigne, Jean-Olivier; Cheshire, Nick; Rosendahl, Ulrich Peter; Quarto, Cesare; Pepper, John

    2016-01-01

    ObjectiveThoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown - this is important because in proximal (Stanford type A) aortic dissections, 10-30% are not accepted for surgery, and 30-50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated using TEVAR.Method...

  5. Access to Posthospitalization Acute Care Facilities is Associated with Payer Status for Open Abdominal Aortic Repair and Open Lower Extremity Revascularization in the Vascular Quality Initiative.

    Science.gov (United States)

    Ulloa, Jesus G; Woo, Karen; Tseng, Chi-Hong; Maggard-Gibbons, Melinda; Rigberg, David

    2017-07-01

    Uninsured patients may not have access to postacute care facilities that play an important role in clinical recovery, and functional outcomes after vascular surgery. We sought to determine whether discharge disposition is associated with insurance status. We retrospectively reviewed data from the Vascular Quality Initiative ® for patients who underwent open abdominal aortic repair, infrainguinal bypass, or suprainguinal bypass (SB) between January 2012 and July 2015. Mixed-effects logistic regression analysis with clustering at the surgeon and facility level was used to calculate 95% confidence intervals for discharge disposition to home, skilled nursing facility (SNF) or rehabilitation (Rehab) facility by payer status (Medicare, Medicaid, Commercial, Military/Veterans Affairs, Non-US Insurance, or Self-pay), with adjustment for patient, operative, and postoperative characteristics. The study cohort comprised 18,478 procedures (open abdominal aortic repair = 2,817; infrainguinal bypass = 11,572; suprainguinal bypass = 4,089) after we excluded procedures with missing data and in-hospital deaths. Twenty-four percent of the cohort was discharged to an SNF or Rehab site. On univariate analysis, the odds ratio (OR) of discharge home was 4.38 (95% CI: 3.33-5.77) for self-pay as compared to Medicare. On mixed-effects analysis, the adjusted odds of discharge home for self-pay as compared to Medicare remained high (OR = 3.09; 95% CI: 2.23-4.26), after adjustment for age, gender, race/ethnicity, preoperative ambulatory status, number of comorbidities, case urgency, total operative time, presence of a postoperative complication, procedure type, and length of stay. Adjusted odds for discharge to SNF (OR = 0.26; 95% CI: 0.15-0.46) and Rehab (OR = 0.50; 95% CI: 0.35-0.72) were lowest for self-pay status. Access to postacute care facilities is associated with insurance status. Self-pay (uninsured) patients are less likely to have access to discharge services that may

  6. Ruptured Abdominal Aortic Aneurysm: Prediction of Mortality From Clinical Presentation and Glasgow Aneurysm Score.

    Science.gov (United States)

    Weingarten, Toby N; Thompson, Lauren T; Licatino, Lauren K; Bailey, Christopher H; Schroeder, Darrell R; Sprung, Juraj

    2016-04-01

    To examine association of presenting clinical acuity and Glasgow Aneurysm Score (GAS) with perioperative and 1-year mortality. Retrospective chart review. Major tertiary care facility. Patients with ruptured abdominal aortic aneurysm (rAAA) from 2003 through 2013. Emergency repair of rAAA. The authors reviewed outcomes after stable versus unstable presentation and by GAS. Unstable presentation included hypotension, cardiac arrest, loss of consciousness, and preoperative tracheal intubation. In total, 125 patients (40 stable) underwent repair. Perioperative mortality rates were 41% and 12% in unstable and stable patients, respectively (pClinical presentation and GAS identified patients with rAAA who were likely to have a poor surgical outcome. GAS≥96 was associated with poor long-term survival, but>20% of these patients survived 1 year. Thus, neither clinical presentation nor GAS provided reliable guidance for decisions regarding futility of surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Valve-sparing aortic root repair in acute type A dissection: how many sinuses have to be repaired for curative surgery?

    Science.gov (United States)

    Urbanski, Paul P; Hijazi, Husam; Dinstak, Witold; Diegeler, Anno

    2013-09-01

    The aim of the study was to evaluate operative and long-term results of valve-sparing aortic root surgery in acute type A dissection. The repair consisted of selective replacement of all dissected and pathological sinuses. Forty-six patients (mean age 62 ± 14; range 29-88 years, 3 with Marfan syndrome), operated on between August 2001 and July 2011 due to acute type A aortic dissection, underwent valve-sparing root repair, resulting in a valve preservation rate of 56% in acute aortic dissection surgery involving the aortic root. Insufficiency grades of 0/1+, 2+, 3+ and 4+ were presented in 16, 17, 12 and 1 patients, respectively. Root repair with resection of the whole of the pathological aortic wall without the use of any glue was performed in all patients. Replacement of 1, 2 or 3 sinuses of Valsalva was performed in 29, 12 and 5 patients, respectively. Concomitant cusp repair was necessary in 7 patients. All perioperative data were collected prospectively and an intention-to-treat analysis was performed. A total of 6 patients (median age 76, range 63-81 years) died, on average 10 months (range 0.9-44) after surgery resulting in an overall survival of 87% at the mean follow-up of 54 ± 37, range 0.9-132 months. The linearized death rate was 2.9%/year, and the actuarial survival rate at 8 years was 85.5 ± 5.6%. No death was related to the aortic valve or aortic root. There were no valve-related events and no patient required reoperation on the proximal aorta/aortic valve during the follow-up. At the last echocardiography (47.8 ± 35.6 months after surgery), 33 patients showed no and 13 patients slight (1+) aortic insufficiency. Curative repair with replacement of all pathological sinuses of Valsalva leads to an excellent long-term outcome. Selected sinus repair is a simple and effective method of curative, valve-sparing root repair in acute aortic dissection because replacement of all sinuses is seldom necessary.

  8. A geometric reappraisal of proximal landing zones for thoracic endovascular aortic repair according to aortic arch types

    NARCIS (Netherlands)

    Marrocco-Trischitta, Massimiliano M.; de Beaufort, Hector W.; Secchi, Francesco; van Bakel, Theodorus M.; Ranucci, Marco; van Herwaarden, Joost A.; Moll, Frans L.; Trimarchi, Santi

    Objective: This study assessed whether the additional use of the aortic arch classification in type I, II, and III may complement Ishimaru's aortic arch map and provide valuable information on the geometry and suitability of proximal landing zones for thoracic endovascular aortic repair. Methods:

  9. Office-based ultrasound screening for abdominal aortic aneurysm.

    Science.gov (United States)

    Blois, Beau

    2012-03-01

    To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). A prospective observational study. Consecutive patients were approached by nonphysician staff. Rural family physician offices in Grand Forks and Revelstoke, BC. The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. A focused “quick screen”, which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (i.e., a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point-of- care ultrasound technology. The screening test can be completed within the time constraints of a

  10. Estimating overdiagnosis in Screening for Abdominal Aortic Aneurysm

    DEFF Research Database (Denmark)

    Johansson, Minna; Hansson, Anders; Brodersen, J.

    2015-01-01

    Clinical context: Abdominal aortic aneurysms (AAAs) are often asymptomatic until they rupture, when the death rate is greater than 80%. If diagnosed before rupture, AAA can be treated with surgery, which has a mortality of 4-5% Diagnostic change: Sweden, the UK, and the US have initiated screenin...

  11. Impact of surgeon and hospital experience on outcomes of abdominal aortic aneurysm repair in New York State.

    Science.gov (United States)

    Meltzer, Andrew J; Connolly, Peter H; Schneider, Darren B; Sedrakyan, Art

    2017-09-01

    This study aimed to assess the impact of the surgeon's and hospital's experience on the outcomes of open surgical repair (OSR) and endovascular aneurysm repair (EVAR) of intact and ruptured abdominal aortic aneurysms (AAAs) in New York State. New York Statewide Planning and Research Cooperative System data were used to identify patients undergoing AAA repair from 2000 to 2011. Characteristics of the provider and hospital were determined by linkage to the New York Office of Professions and National Provider Identification databases. Distinct hierarchical logistic regression models for EVAR and OSR for intact and ruptured AAAs were created to adjust for the patient's comorbidities and to evaluate the impact of the surgeon's and hospital's experience on outcomes. The provider's years since medical school graduation as well as annual volume of the facility and provider are examined in tertiles. Adjusted odds ratios and 95% confidence intervals are presented. A total of 18,842 patients underwent AAA repair by a vascular surgeon. For intact AAAs (n = 17,118), 26.2% of patients underwent OSR and 73.8% underwent EVAR. For ruptured AAAs (n = 1724), 63.9% underwent OSR and 36.1% underwent EVAR. After intact AAA repair, OSR adjusted outcomes were significantly influenced by the surgeon's annual volume but not by the facility's volume or the surgeon's age. The lowest volume providers (1-4 OSRs) had higher in-hospital mortality rates than high-volume (>11 OSRs) surgeons (adjusted odds ratio, 1.87 [95% confidence interval, 1.1-3.17]). Low-volume providers also had higher odds of major complications (1.23 [1-1.51]). For patients with intact AAA undergoing EVAR, mortality was higher at low-volume facilities (2.6 [1.3-5.3] and 2.7 [1.5-4.8] for 27 OSRs for ruptured AAA) centers (1.56 [1.02-2.39]), whereas low-volume physicians (<4 OSRs for ruptured AAA) had higher odds of major complications (1.58 [1.04-2.41]). In the case of EVAR for rupture, there were no characteristics of

  12. Ameliorative role of gemfibrozil against partial abdominal aortic constriction-induced cardiac hypertrophy in rats.

    Science.gov (United States)

    Singh, Amrit Pal; Singh, Randhir; Krishan, Pawan

    2015-04-01

    Fibrates are peroxisome proliferator-activated receptor-α agonists and are clinically used for treatment of dyslipidemia and hypertriglyceridemia. Fenofibrate is reported as a cardioprotective agent in various models of cardiac dysfunction; however, limited literature is available regarding the role of gemfibrozil as a possible cardioprotective agent, especially in a non-obese model of cardiac remodelling. The present study investigated the role of gemfibrozil against partial abdominal aortic constriction-induced cardiac hypertrophy in rats. Cardiac hypertrophy was induced by partial abdominal aortic constriction in rats and they survived for 4 weeks. The cardiac hypertrophy was assessed by measuring left ventricular weight to body weight ratio, left ventricular wall thickness, and protein and collagen content. The oxidative stress in the cardiac tissues was assessed by measuring thiobarbituric acid-reactive substances, superoxide anion generation, and reduced glutathione level. The haematoxylin-eosin and picrosirius red staining was used to observe cardiomyocyte diameter and collagen deposition, respectively. Moreover, serum levels of cholesterol, high-density lipoproteins, triglycerides, and glucose were also measured. Gemfibrozil (30 mg/kg, p.o.) was administered since the first day of partial abdominal aortic constriction and continued for 4 weeks. The partial abdominal aortic constriction-induced cardiac oxidative stress and hypertrophy are indicated by significant change in various parameters used in the present study that were ameliorated with gemfibrozil treatment in rats. No significant change in serum parameters was observed between various groups used in the present study. It is concluded that gemfibrozil ameliorates partial abdominal aortic constriction-induced cardiac oxidative stress and hypertrophy and in rats.

  13. Hospital costs and benefits of screening for abdominal aortic aneurysms. Results from a randomised population screening trial

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Fasting, H

    2002-01-01

    to analyse the hospital costs and benefits of screening older males for abdominal aortic aneurysm (AAA). MATERIALS and......to analyse the hospital costs and benefits of screening older males for abdominal aortic aneurysm (AAA). MATERIALS and...

  14. Mass or high-risk screening for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Henneberg, E W; Fasting, H

    1997-01-01

    Abdominal aortic aneurysm (AAA) is known to be associated with various diseases, especially hypertension, acute myocardial infarction (AMI), chronic obstructive airway disease (COAD), and intermittent claudication. These associations have led to a debate about whether screening of older men for AAA...

  15. The role of annular dimension and annuloplasty in tricuspid aortic valve repair.

    Science.gov (United States)

    de Kerchove, Laurent; Mastrobuoni, Stefano; Boodhwani, Munir; Astarci, Parla; Rubay, Jean; Poncelet, Alain; Vanoverschelde, Jean-Louis; Noirhomme, Philippe; El Khoury, Gebrine

    2016-02-01

    Valve sparing reimplantation can improve the durability of bicuspid aortic valve repair compared with subcommissural annuloplasty, especially in patients with a large basal ring. This study analyses the effect of basal ring size and annuloplasty on valve repair in the setting of a tricuspid aortic valve. From 1995 to 2013, 382 patients underwent elective tricuspid aortic valve repair. We included only those undergoing subcommissural annuloplasty, valve sparing reimplantation or no annuloplasty and in whom intraoperative transoesophageal echocardiography images were available for retrospective pre- and post-repair basal ring measurements (n = 323, subcommissural annuloplasty: 146, valve sparing reimplantation: 154, no annuloplasty: 23). In a subgroup of patients with available echocardiographic images, basal ring was retrospectively measured at the latest follow-up or prior to reoperation. subcommissural annuloplasty and valve sparing reimplantation were compared after matching for degree of aortic regurgitation and root size. All three groups differed significantly for most of preoperative characteristics. Hospital mortality was 0.9%. The median follow-up was 4.7 years. At 8 years, overall survival was 80 ± 5%. Freedom from reoperation and freedom from aortic regurgitation >1+ were 92 ± 5% and 71 ± 8%, respectively. In multivariate analysis, predictors of aortic regurgitation >1+ were left ventricular end-diastolic diameter (P = 0.003), cusp repair (P = 0.006), body surface area (P = 0.01) and subcommissural annuloplasty (P = 0.05). In subcommissural annuloplasty, freedom from aortic regurgitation >1+ was lower for patients with basal ring ≥28 mm compared with patients with basal ring 1+ was independent of basal ring size (P = 0.38). In matched comparison between subcommissural annuloplasty and valve sparing reimplantation, freedom from aortic regurgitation >1+ was not significantly different (P = 0.06), but in patients with basal ring ≥28 mm, valve sparing

  16. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  17. Implementation of the Continuous AutoTransfusion System (C.A.T.S) in open abdominal aortic aneurysm repair: an observational comparative cohort study.

    LENUS (Irish Health Repository)

    Tawfick, Wael A

    2008-01-01

    The use of the Continuous AutoTransfusion System (C.A.T.S; Fresenius Hemotechnology, Bad Homburg v.d.H., Germany), which conserves allogenic blood, is reported in 187 patients having abdominal aortic aneurysm repair during a 9-year period. Patients were allocated to C.A.T.S if a Haemovigilance technician was available. A mean of 685 mL of retrieved blood was reinfused in 101 patients receiving C.A.T.S; 61% required 2 U or less. All control patients required 3 U or more of allogenic blood. Allogenic transfusion in C.A.T.S patients decreased significantly (P < .0001). Mean intensive care unit stay was significantly reduced in C.A.T.S patients (P = .042). Mean postoperative hospital stay was 18 days for C.A.T.S group and 25 days in control patients (P = .014). The respective 30-day mortality was 12% versus 19% (P = .199). The C.A.T.S markedly reduced the amount of blood transfused, was associated with reduced intensive care unit and postoperative hospital stay, and was cost-effective.

  18. Plasma levels of plasmin-antiplasmin-complexes are predictive for small abdominal aortic aneurysms expanding to operation-recommendable sizes

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Jørgensen, B; Fasting, H

    2001-01-01

    Three proteolytic systems seem involved in the aneurysmal degradation of the aortic wall. Plasmin is a common activator of the systems and could thus be predictive for the progression of abdominal aortic aneurysms (AAAs).......Three proteolytic systems seem involved in the aneurysmal degradation of the aortic wall. Plasmin is a common activator of the systems and could thus be predictive for the progression of abdominal aortic aneurysms (AAAs)....

  19. Intra-abdominal hypertension and abdominal compartment syndrome in association with ruptured abdominal aortic aneurysm in the endovascular era: vigilance remains critical.

    Science.gov (United States)

    Bozeman, Matthew C; Ross, Charles B

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  20. Abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes S.

    2010-01-01

    Although the number of elective operations for abdominal aortic aneurysms (AAA) is increasing, the sex- and age-standardised mortality rate of AAAs continues to rise, especially among men aged 65 years or more. The lethality of ruptured AAA continues to be 80-95%, compared with 5-7% by elective...... surgery of symptomfree AAA. In order to fulfil all WHO, European, and Danish criteria for screening, a randomised hospitalbased screening trial of 12,639 65-73 year old men in Viborg County (Denmark) was initiated in 1994. It seemed that US screening is a valid, suitable and acceptable method of screening...... patients without previous hospital discharge diagnoses due to cardiovascular disease than among similar men without AAA. The absolute risk difference after 5 years was 16%. So, they will benefit from general cardiovascular preventive action as smoking cessation, statins and low-dose aspirin, which could...

  1. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  2. Pain following the repair of an abdominal hernia

    DEFF Research Database (Denmark)

    Hansen, Mark Berner; Andersen, Kenneth Geving; Crawford, Michael Edward

    2010-01-01

    Pain and other types of discomfort are frequent symptoms following the repair of an abdominal hernia. After 1 year, the incidence of light to moderate pain following inguinal hernia repair is as high as 10% and 2% for severe disabling chronic pain. Postoperative chronic pain not only affects......, psychosocial characteristics, and surgical procedures) related to the postoperative pain conditions. Furthermore, the mechanisms for both acute and chronic pain are presented. We focus on inguinal hernia repair, which is the most frequent type of abdominal hernia surgery that leads to chronic pain. Finally...

  3. Association between osteopontin and human abdominal aortic aneurysm.

    Science.gov (United States)

    Golledge, Jonathan; Muller, Juanita; Shephard, Neil; Clancy, Paula; Smallwood, Linda; Moran, Corey; Dear, Anthony E; Palmer, Lyle J; Norman, Paul E

    2007-03-01

    In vitro and animal studies have implicated osteopontin (OPN) in the pathogenesis of aortic aneurysm. The relationship between serum concentration of OPN and variants of the OPN gene with human abdominal aortic aneurysm (AAA) was investigated. OPN genotypes were examined in 4227 subjects in which aortic diameter and clinical risk factors were measured. Serum OPN was measured by ELISA in two cohorts of 665 subjects. The concentration of serum OPN was independently associated with the presence of AAA. Odds ratios (and 95% confidence intervals) for upper compared with lower OPN tertiles in predicting presence of AAA were 2.23 (1.29 to 3.85, P=0.004) for the population cohort and 4.08 (1.67 to 10.00, P=0.002) for the referral cohort after adjusting for other risk factors. In 198 patients with complete follow-up of aortic diameter at 3 years, initial serum OPN predicted AAA growth after adjustment for other risk factors (standardized coefficient 0.24, P=0.001). The concentration of OPN in the aortic wall was greater in patients with small AAAs (30 to 50 mm) than those with aortic occlusive disease alone. There was no association between five single nucleotide polymorphisms or haplotypes of the OPN gene and aortic diameter or AAA expansion. Serum and tissue concentrations of OPN are associated with human AAA. We found no relationship between variation of the OPN gene and AAA. OPN may be a useful biomarker for AAA presence and growth.

  4. Endovascular management of lap belt-related abdominal aortic injury in a 9-year-old child.

    Science.gov (United States)

    Papazoglou, Konstantinos O; Karkos, Christos D; Kalogirou, Thomas E; Giagtzidis, Ioakeim T

    2015-02-01

    Blunt abdominal aortic trauma is a rare occurrence in children with only a few patients having been reported in the literature. Most such cases have been described in the context of lap belt injuries. We report a 9-year-old boy who suffered lap belt trauma to the abdomen during a high-speed road traffic accident resulting to the well-recognized pattern of blunt abdominal injury, that is, the triad of intestinal perforation, fractures of the lumbar spine, and abdominal aortic injury. The latter presented with lower limb ischemia due to dissection of the infrarenal aorta and right common iliac artery. Revascularization was achieved by endovascular means using 2 self-expanding stents in the infrarenal aorta and the right common iliac artery. This case is one of the few reports of lap belt-related acute traumatic abdominal aortic dissection in a young child and highlights the feasibility of endovascular management in the pediatric population. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  6. Elastin-derived peptides promote abdominal aortic aneurysm formation by modulating M1/M2 macrophage polarization1

    Science.gov (United States)

    Dale, Matthew A; Xiong, Wanfen; Carson, Jeffrey S; Suh, Melissa K; Karpisek, Andrew D.; Meisinger, Trevor M.; Casale, George P.; Baxter, B. Timothy

    2016-01-01

    Abdominal aortic aneurysm (AAA) is a dynamic vascular disease characterized by inflammatory cell invasion and extracellular matrix (ECM) degradation. Damage to elastin in the ECM results in release of elastin-derived peptides (EDPs), which are chemotactic for inflammatory cells such as monocytes. Their effect on macrophage polarization is less well known. Pro-inflammatory M1 macrophages initially are recruited to sites of injury but, if their effects are prolonged, they can lead to chronic inflammation that prevents normal tissue repair. Conversely, anti-inflammatory M2 macrophages reduce inflammation and aid in wound healing. Thus, a proper M1/M2 ratio is vital for tissue homeostasis. AAA tissue reveals a high M1/M2 ratio where pro-inflammatory cells and their associated markers dominate. In the present study, in vitro treatment of bone marrow-derived macrophages with EDPs induced M1 macrophage polarization. By using C57Bl/6 mice, antibody-mediated neutralization of EDPs reduced aortic dilation, matrix metalloproteinase activity, and pro-inflammatory cytokine expression at early and late time points after aneurysm induction. Furthermore, direct manipulation of the M1/M2 balance altered aortic dilation. Injection of M2 polarized macrophages reduced aortic dilation after aneurysm induction. EDPs promoted a pro-inflammatory environment in aortic tissue by inducing M1 polarization and neutralization of EDPs attenuated aortic dilation. The M1/M2 imbalance is vital to aneurysm formation. PMID:27183603

  7. Trans-aortic repair of a sinus of valsalva aneurysm.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Ieromonachos, Constantinos; Stavridis, George; Antoniou, Theofani A; Athanassopoulos, George; Cokkinos, Dennis V; Alivizatos, Peter A

    2007-01-01

    Sinus of Valsalva aneurysms are rare and vary in their presentation and approach of surgical repair. We report on a case of isolated right sinus of Valsalva aneurysm that underwent successful excision and patch repair with individual sutures placed through the annulus of the aortic valve.

  8. Can Surgeons Assess CT Suitability for Endovascular Repair (EVAR) in Ruptured Abdominal Aortic Aneurysm? Implications for a Ruptured EVAR Trial

    International Nuclear Information System (INIS)

    Rayt, Harjeet; Lambert, Kelly; Bown, Matthew; Fishwick, Guy; Morgan, Robert; McCarthy, Mark; London, Nick; Sayers, Robert

    2008-01-01

    The purpose of this study was to determine whether surgeons without formal radiological training are able to assess suitability of patients with ruptured abdominal aortic aneurysms (AAA) for EVAR. The CT scans of 20 patients with AAA were reviewed under timed conditions by six vascular surgeons. Twenty minutes was allocated per scan. They were asked to determine if each aneurysm would be treatable by EVAR in the emergency setting and, if so, to measure for device selection. The results were then compared with those of a vascular radiologist. Six surgeons agreed on the suitability of endovascular repair in 45% of cases (95% CI, 23.1-68.5%; 9/20 scans; κ = 0.41 [p = 0.01]) and concurred with the radiologist in eight of these. Individually, agreement ranged from 13 to 16 of the 20 scans, 65-80% between surgeons. The kappa value for agreement between all the surgeons and the radiologist was 0.47 (p = 0.01, moderate agreement). For the individual surgeons, this ranged from 0.3 to 0.6 (p = 0.01). In conclusion, while overall agreement was moderate between the surgeons and the radiologist, it is clear that if surgeons are to assess patients for ruptured EVAR in the future, focused training of surgical trainees is required.

  9. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    Science.gov (United States)

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  10. Comparison of hybrid endovascular and open surgical repair for proximal aortic arch diseases.

    Science.gov (United States)

    Kang, Woong Chol; Ko, Young-Guk; Shin, Eak Kyun; Park, Chul-Hyun; Choi, Donghoon; Youn, Young Nam; Lee, Do Yun

    2016-01-15

    To compare the outcomes of hybrid endovascular and open surgical repair for proximal aortic arch diseases. A total of 55 consecutive patients with aortic arch aneurysm or aortic dissection involving any of zone 0 to 1 (39 male, age 63.4 ± 14.3 years) underwent a hybrid endovascular repair (n=35) or open surgical repair (n=20) from 2006 to 2014 were analyzed retrospectively. Perioperative and late outcomes were compared. Baseline characteristics were similar between the two groups, except age and EuroSCORE II, which were higher in the hybrid group. Perioperative mortality or stroke was not significantly different between the two groups, however, tended to be lower in the hybrid repair group than in the open repair group (11.4% vs. 30.0%, p=0.144). Incidences of other morbidities did not differ. During follow-up, over-all survival was similar between the hybrid and the open repair was similar (87.3% vs. 79.7% at 1 year and 83.8% vs. 72.4% at 3 years; p=0.319). However, reintervention-free survival was significantly lower for hybrid repair compared with open repair (83.8% vs. 100% at 1 year and 65.7% vs. 100% at 3 years; p=0.022). Hybrid repair of proximal aortic disease showed comparable perioperative and late outcomes compared with open surgical repair despite a higher reintervention rate during follow-up. Therefore, hybrid repair may be considered as an acceptable treatment alternative to surgery especially in patients at high surgical risk. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. A Variant in LDLR Is Associated With Abdominal Aortic Aneurysm

    NARCIS (Netherlands)

    Bradley, Declan T.; Hughes, Anne E.; Badger, Stephen A.; Jones, Gregory T.; Harrison, Seamus C.; Wright, Benjamin J.; Bumpstead, Suzannah; Baas, Annette F.; Gretarsdottir, Solveig; Burnand, Kevin; Child, Anne H.; Clough, Rachel E.; Cockerill, Gillian; Hafez, Hany; Scott, D. Julian A.; Ariens, Robert A. S.; Johnson, Anne; Sohrabi, Soroush; Smith, Alberto; Thompson, Matthew M.; van Bockxmeer, Frank M.; Waltham, Matthew; Matthiasson, Stefan E.; Thorleifsson, Gudmar; Thorsteinsdottir, Unnur; Blankensteijn, Jan D.; Teijink, Joep A. W.; Wijmenga, Cisca; de Graaf, Jacqueline; Kiemeney, Lambertus A.; Wild, John B.; Edkins, Sarah; Gwilliam, Rhian; Hunt, Sarah E.; Potter, Simon; Lindholt, Jes S.; Golledge, Jonathan; Norman, Paul E.; van Rij, Andre; Powell, Janet T.; Eriksson, Per; Stefansson, Kari; Thompson, John R.; Humphries, Steve E.; Sayers, Robert D.; Deloukas, Panos; Samani, Nilesh J.; Bown, Matthew J.

    2013-01-01

    Background Abdominal aortic aneurysm (AAA) is a common cardiovascular disease among older people and demonstrates significant heritability. In contrast to similar complex diseases, relatively few genetic associations with AAA have been confirmed. We reanalyzed our genome-wide study and carried

  12. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  13. Is tube repair of aortic aneurysm followed by aneurysmal change in the common iliac arteries?

    Science.gov (United States)

    Provan, J L; Fialkov, J; Ameli, F M; St Louis, E L

    1990-10-01

    To address the concern that tube repair of an abdominal aortic aneurysm might be followed by aneurysmal change in the common iliac arteries, 23 patients who had undergone the operation were re-examined 3 to 5 years later. Although 9 had had minimal ectasia of these arteries preoperatively, in none of the 23 was there symptomatic or radiologic evidence of aneurysmal change on follow-up. Measurements of the maximum intraluminal diameters were made by computed tomography; they indicated no significant differences between the preoperative and follow-up sizes of the common iliac arteries. The variation in time to follow-up also showed no significant correlation with change in artery diameter.

  14. Chimney-Graft as a Bail-Out Procedure for Endovascular Treatment of an Inflammatory Juxtarenal Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Francesca Fratesi

    2015-01-01

    Full Text Available Inflammatory and juxtarenal Abdominal Aortic Aneurysm (j-iAAA represents a technical challenge for open repair (OR due to the peculiar anatomy, extensive perianeurysmal fibrosis, and dense adhesion to the surrounding tissues. A 68-year-old man with an 11 cm asymptomatic j-iAAA was successfully treated with elective EVAR and chimney-graft (ch-EVAR without postprocedural complications. Target vessel patency and normal renal function are present at 24-month follow-up. The treatment of j-iAAA can be technically challenging. ch-EVAR is a feasible and safe bail-out method for elective j-iAAA with challenging anatomy.

  15. Low-dose aspirin and rupture of abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Wemmelund, Holger; Jørgensen, Trine M M; Høgh, Annette

    2016-01-01

    OBJECTIVE: The use of low-dose aspirin (acetylsalicylic acid [ASA]) has been suggested to attenuate growth of abdominal aortic aneurysms (AAAs), yet solid clinical evidence of this hypothesis is still missing. This study aimed to investigate whether preadmission ASA use influenced the risk...

  16. Antimicrobial treatment to impair expansion of abdominal aortic aneurysm (AAA)

    DEFF Research Database (Denmark)

    Bergqvist, David; Lindeman, Johannes H N; Lindholt, Jes S

    2013-01-01

    Antimicrobial treatment to attenuate expansion of abdominal aortic aneurysm has been suggested, especially with the focus on Chlamydophila. In this systematic literature review only four randomized trials were identified. In two small studies there is an indication of an effect of roxithromycin. ...

  17. A variant in LDLR is associated with abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Bradley, Declan T; Hughes, Anne E; Badger, Stephen A

    2013-01-01

    Abdominal aortic aneurysm (AAA) is a common cardiovascular disease among older people and demonstrates significant heritability. In contrast to similar complex diseases, relatively few genetic associations with AAA have been confirmed. We reanalyzed our genome-wide study and carried through to re...

  18. The cardiac cycle is a major contributor to variability in size measurements of abdominal aortic aneurysms by ultrasound

    DEFF Research Database (Denmark)

    Grøndal, Nikolaj Fibiger; Bramsen, Morten; Thomsen, Marie Dahl

    2012-01-01

    The objective of the study was to evaluate the impact of the cardiac cycle on ultrasound measurements of abdominal aortic aneurysm (AAA) diameters.......The objective of the study was to evaluate the impact of the cardiac cycle on ultrasound measurements of abdominal aortic aneurysm (AAA) diameters....

  19. Contemporary results of surgical repair of recurrent aortic arch obstruction.

    Science.gov (United States)

    Mery, Carlos M; Khan, Muhammad S; Guzmán-Pruneda, Francisco A; Verm, Raymond; Umakanthan, Ramanan; Watrin, Carmen H; Adachi, Iki; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2014-07-01

    There is a paucity of data on the current outcomes of surgical intervention for recurrent aortic arch obstruction (RAAO) after initial aortic arch repair in children. The goal of this study is to report the long-term results in these patients. All patients undergoing surgical intervention for RAAO at Texas Children's Hospital from 1995 to 2012 were included. The cohort was divided into four groups based on initial procedure: (1) simple coarctation repair, (2) Norwood procedure, (3) complex congenital heart disease, and (4) interrupted aortic arch. A total of 48 patients age 9 months (range, 22 days to 36 years) underwent 49 procedures for RAAO. All patients had an anatomic repair consisting of either patch aortoplasty (n=27, 55%), aortic arch advancement (n=8, 16%), sliding arch aortoplasty (n=6, 12%), placement of an interposition graft (n=2, 17%), reconstruction with donor allograft (n=4, 8%), extended end-to-end anastomosis (n=1, 2%), or redo Norwood-type reconstruction (n=1, 2%). Most procedures (n=46, 94%) were performed through a median sternotomy using cardiopulmonary bypass. At a median follow-up of 6.1 years (range, 9 days to 17 years), only 2 patients required surgical or catheter-based intervention for RAAO. Hypertension was present in 10% of patients at last follow-up. There were no neurologic or renal complications. There was 1 perioperative death after an aortic arch advancement in group 1. Four other patients have died during follow-up, none of the deaths related to RAAO. Anatomic repair of RAAO is a safe procedure associated with low morbidity and mortality, and low long-term reintervention rates. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Combined laparoscopic and open technique for repair of congenital abdominal hernia

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-01-01

    Abstract Background: Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. Materials and methods: We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. Results: The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Conclusions: Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality. PMID:29049186

  1. Association of ficolin-3 with abdominal aortic aneurysm presence and progression

    DEFF Research Database (Denmark)

    Fernandez-García, C-E; Burillo, E; Lindholt, J S

    2017-01-01

    Essentials Abdominal aortic aneurysm (AAA) is asymptomatic and its evolution unpredictable. To find novel potential biomarkers of AAA, microvesicles are an excellent source of biomarkers. Ficolin-3 is increased in microvesicles obtained from activated platelets and AAA tissue. Increased ficolin-3...... plasma levels are associated with AAA presence and progression. SUMMARY: Background Abdominal aortic aneurysm (AAA) patients are usually asymptomatic and AAA evolution is unpredictable. Ficolin-3, mainly synthesized by the liver, is a molecule of the lectin complement-activation pathway involved in AAA...... pathophysiology. Objectives To define extra-hepatic sources of ficolin-3 in AAA and investigate the role of ficolin-3 as a biomarker of the presence and progression of AAA. Methods Microvesicles (exosomes and microparticles) were isolated from culture-conditioned medium of ADP-activated platelets, as well as from...

  2. Aorto-enteric Fistula 15 Years After Uncomplicated Endovascular Aortic Repair with Unforeseen Onset of Endocarditis

    DEFF Research Database (Denmark)

    Kadhim, M M K; Rasmussen, J B G; Eiberg, J P

    2016-01-01

    Introduction Aorto-enteric fistula after endovascular aortic repair is an exceedingly rare but serious condition. Report A rare case of a fistula between the excluded aortic sac and the transverse colon 15 years after endovascular aortic repair is described. Onset was endocarditis without...... such as endocarditis, which in this case probably occurred as metastatic sepsis from endograft infection....

  3. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  4. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    Science.gov (United States)

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  5. Patients’ perceptions of conservative treatment for a small abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Tomee SM

    2018-01-01

    Full Text Available Stephanie M Tomee,1 Winifred A Gebhardt,2 Jean-Paul PM de Vries,3 Victoria C Hamelinck,1 Jaap F Hamming,1 Jan HN Lindeman1 1Department of Surgery, Leiden University Medical Center, Leiden, 2Health, Medical and Neuropsychology Unit, Institute of Psychology, Leiden University, Leiden, 3Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, Leiden, the Netherlands Background: An abdominal aortic aneurysm (AAA is a progressive, generally symptomless disease that could ultimately result in a fatal rupture. Current guidelines advise conservative follow-up, and preventive surgical repair once the risk of rupture outweighs the cost of repair (55 mm in men. In developed countries, the majority of patients are diagnosed with AAAs less than 55 mm, and so enter a period of conservative surveillance. An important question is how patients perceive and cope with risk of rupture, AAA diagnosis and treatment, and presented AAA information. The goal of this study was to gain insight into patients’ perceptions of conservative treatment for a small AAA to increase patient satisfaction.Methods: We conducted semistructured in-depth interviews and used questionnaires measuring health-related quality of life (RAND 36-Item Health Survey 1.0, illness-perceptions (Illness Perception Questionnaire – Revised, and anxiety and depression (Hospital Anxiety and Depression Scale. Interviews were audio recorded and transcript contents were analyzed based on grounded theory. Mean scores of the questionnaires were compared to (population reference groups.Results: This study included ten male patients under surveillance for a small AAA from two hospitals in the Netherlands. Patients expressed no fear for AAA rupture, and also reported low levels of anxiety and depression in both the interviews and the Hospital Anxiety and Depression Scale. The presence of an AAA did not affect their social life or emotional well-being. The reported poorer physical health on RAND 36

  6. Personal resources and satisfaction with life in Marfan syndrome patients with aortic pathology and in abdominal aortic aneurysm patients.

    Science.gov (United States)

    Stanišić, Michał-Goran; Rzepa, Teresa; Gawrońska, Alicja; Kubaszewski, Przemysław; Putowski, Maciej; Stefaniak, Sebastian; Perek, Bartłomiej

    2018-03-01

    Whether or not the source of aortic pathology is Marfan syndrome (MFS) or other processes leading to development of abdominal aorta aneurysms (AAA), the awareness of pathology may lead to an emotional upset and low assessment of satisfaction with life. To assess, in regard to MFS patients with aortic pathology and to abdominal aortic aneurysm patients: 1) whether or not self-efficacy (SE) and health locus of control (HLoC) affect the patients' satisfaction with life; 2) whether the two groups of patients differ in terms of mental dispositions. The study population consisted of 16 MFS patients with aortic pathology and 16 AAA patients, 9 men and 7 women in each group. The mean age of the MFS patients was 28.5 ±8.214, and of the AAA patients 64.25 ±7.019. The following scales were applied: Generalized Self-Efficacy Scale, Satisfaction With Life Scale, Multidimensional Health Locus of Control Scale. Abdominal aorta aneurysms patients compared to MFS patients gave a higher rating for SE ( MD = 33.94 and MD = 29.56), internal health locus of control ( MD = 25.00 and MD = 21.13), external personal HL o C ( MD = 24.50 and MD = 19.25), external impersonal HLoC ( MD = 23.06 and MD = 18.25), and satisfaction with life ( M = 22.06 and M = 20.13). Internal and external HL o C were significantly lower in MFS patients compared to AAA patients. In patients with aortic diseases, special attention must be paid to the state of personal resources (PR). Interactions made by medical professionals should focus on enhancing PR supporting the patients' self-knowledge on their SE. This will help to improve their satisfaction with life and form a positive attitude to the illness.

  7. A tetrad of bicuspid aortic valve association: A single-stage repair

    Science.gov (United States)

    Barik, Ramachandra; Patnaik, A. N.; Mishra, Ramesh C.; Kumari, N. Rama; Gulati, A. S.

    2012-01-01

    We report a 27 years old male who presented with a combination of both congenital and acquired cardiac defects. This syndrome complex includes congenital bicuspid aortic valve, Seller's grade II aortic regurgitation, juxta- subclavian coarctation, stenosis of ostium of left subclavian artery and ruptured sinus of Valsalva aneurysm without any evidence of infective endocarditis. This type of constellation is extremely rare. Neither coarctation of aorta with left subclavian artery stenosis nor the rupture of sinus Valsalva had a favorable pathology for percutaneus intervention. Taking account into morbidity associated with repeated surgery and anesthesia patient underwent a single stage surgical repair of both the defects by two surgical incisions. The approaches include median sternotomy for rupture of sinus of Valsalva and lateral thoracotomy for coarctation with left subclavian artery stenosis. The surgery was uneventful. After three months follow up echocardiography showed mild residual gradient across the repaired coarctation segment, mild aortic regurgitation and no residual left to right shunt. This patient is under follow up. This is an extremely rare case of single stage successful repair of coarctation and rupture of sinus of Valsalva associated with congenital bicuspid aortic valve. PMID:22629035

  8. Angular (Gothic) aortic arch leads to enhanced systolic wave reflection, central aortic stiffness, and increased left ventricular mass late after aortic coarctation repair: evaluation with magnetic resonance flow mapping.

    Science.gov (United States)

    Ou, Phalla; Celermajer, David S; Raisky, Olivier; Jolivet, Odile; Buyens, Fanny; Herment, Alain; Sidi, Daniel; Bonnet, Damien; Mousseaux, Elie

    2008-01-01

    We sought to investigate the mechanism whereby a particular deformity of the aortic arch, an angulated Gothic shape, might lead to hypertension late after anatomically successful repair of aortic coarctation. Fifty-five normotensive patients with anatomically successful repair of aortic coarctation and either a Gothic (angulated) or a Romanesque (smooth and rounded) arch were studied with magnetic resonance angiography and flow mapping in both the ascending and descending aortas. Systolic waveforms, central aortic stiffness, and pulse velocity were measured. We hypothesized that arch angulation would result in enhanced systolic wave reflection with loss of energy across the aortic arch, as well as increased central aortic stiffness. Twenty patients were found to have a Gothic, and 35 a Romanesque, arch. Patients with a Gothic arch showed markedly augmented systolic wave reflection (12 +/- 6 vs 5 +/- 0.3 mL, P Gothic arch (5.6 +/- 1.1 vs 4.1 +/- 1 m/s, P Gothic aortic arch is associated with increased systolic wave reflection, as well as increased central aortic stiffness and left ventricular mass index. These findings explain (at least in part) the association between this pattern of arch geometry and late hypertension at rest and on exercise in subjects after coarctation repair.

  9. Reduction in allogeneic blood products with routine use of autotransfusion in open elective infrarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Courtemanche, Karim; Elkouri, Stephane; Dugas, Jean-Philippe; Beaudoin, Nathalie; Bruneau, Luc; Blair, Jean-François

    2013-11-01

    Concern about allogeneic blood product cost and complications has prompted interest in blood conservation techniques. Intraoperative autotransfusion (IAT) is currently not used routinely by vascular surgeons in open elective infrareanl abdominal aortic aneurysm (AAA) repair. The objective of this study is to review our experience with IAT and its impact on blood transfusion. We retrospectively reviewed the medical records of consecutive patients treated electively over a 4-year period and compared 2 strategy related to IAT, routine use IAT (rIAT) versus on-demand IAT (oIAT). Outcomes measured were number of units of allogeneic red blood cells and autologous red blood cells transfused intraoperatively and postoperatively, preoperative, postoperative, and discharge hemoglobin levels; postoperative infections; length of postoperative intensive care stay; and length of hospital stay. T-independent and Fisher exact test were used. A total of 212 patients were included, 38 (18%) in the rIAT and 174 (82%) in the oIAT. Groups were similar except for an inferior creatinine and a superior mean aneurysm diameter for the rIAT group. Patients in the rIAT group had a lower rate of transfusion (26% vs 54%, P = .002) and a lower mean number of blood unit transfused (0.8 vs 1.8, P = .048). These findings were still more significant for AAA larger than 60 mm (18% rIAT vs 62% oIAT, P = .0001). Postoperative hemoglobin was superior in the rIAT group (107 vs 101 g/L, P = .01). Mean postoperative intensive care length of stay was shorter for the rIAT group (1.1 vs 1.8 days, P = .01). No difference was noted for infection, mortality, or hospital length of stay. The rIAT reduced the exposure to allogeneic blood products by more than 50%, in particular for patients with AAA larger than 60 mm. These results support the use of rIAT for open elective infrarenal AAA repair.

  10. Long-term benefit and cost-effectiveness analysis of screening for abdominal aortic aneurysms from a randomized controlled trial

    DEFF Research Database (Denmark)

    Lindholt, J S; Sørensen, J; Søgaard, Rikke

    2010-01-01

    The aim was to estimate long-term mortality benefits and cost-effectiveness of screening for abdominal aortic aneurysm (AAA) in men aged 64-73 years.......The aim was to estimate long-term mortality benefits and cost-effectiveness of screening for abdominal aortic aneurysm (AAA) in men aged 64-73 years....

  11. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  12. Hybrid Endovascular Aortic Aneurysm Repair: Preservation of Pelvic Perfusion with External to Internal Iliac Artery Bypass.

    Science.gov (United States)

    Mansukhani, Neel A; Havelka, George E; Helenowski, Irene B; Rodriguez, Heron E; Hoel, Andrew W; Eskandari, Mark K

    2017-07-01

    Diminished pelvic arterial flow as a result of intentional coverage/embolization of internal iliac arteries (IIA) during isolated endovascular common iliac artery aneurysm (CIAA) repair or endovascular repair of abdominal aortic aneurysms (EVAR) may result in symptomatic pelvic ischemia. Although generally well tolerated, in severe cases, pelvic ischemia may manifest as recalcitrant buttock claudication, vasculogenic impotence, or perineal, vesicle, rectal, and/or spinal cord ischemia. Branched graft technology has recently become available; however, many patients are not candidates for endovascular repair with these devices. Therefore, techniques to preserve pelvic arterial flow are needed. We reviewed our outcomes of isolated endovascular CIAA repair or EVAR in conjunction with unilateral external-internal iliac artery bypass. Single-center, retrospective review of 10 consecutive patients who underwent hybrid endovascular abdominal aortic aneurysm (AAA) or CIAA repair with concomitant external-internal iliac artery bypass between 2006 and 2015. Demographics, index procedural details, postoperative symptoms, hospital length of stay (LOS), follow-up imaging, and bypass patency were recorded. The cohort of 10 patients was all men with a mean age of 71 years (range: 56-84). Hybrid repair consisted of contralateral IIA coil embolization followed by EVAR with external iliac artery-internal iliac artery (EIA-IIA) bypass. All EIA-IIA bypasses were performed via a standard lower quadrant retroperitoneal approach with a prosthetic bypass graft. Technical success was 100%, and there were no perioperative deaths. One patient developed transient paraplegia, 1 patient had buttock claudication on the side of his hypogastric embolization contralateral to his iliac bypass, and 1 developed postoperative impotence. 20% of patients sustained long-term complications (buttock claudication and postoperative impotence). Mean LOS was 2.8 days (range: 1-9 days). Postoperative imaging

  13. Glycated Hemoglobin Is Associated With the Growth Rate of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Kristensen, Katrine Lawaetz; Dahl, Marie; Rasmussen, Lars Melholt

    2017-01-01

    and HbA1c in the total study population (P=0.002). Both crude and adjusted analyses identified slower growth for the group with the highest HbA1c tertile compared with the lowest HbA1c tertile. After 3 years, the mean difference was 1.8 mm (confidence interval, 0.98–2.64). Similar significant differences......OBJECTIVE—: An inverse association between abdominal aortic aneurysms (AAAs) and diabetes mellitus exists; however, the cause remains unknown. This study aimed to evaluate whether the degree of glycemia is associated with aneurysm growth. APPROACH AND RESULTS—: The study was based on VIVA trial...... (Viborg Vascular), the randomized clinically controlled screening trial for abdominal aortic aneurysm in men aged 65 to 74 years in the Central Denmark Region. The screening included measurement of the abdominal aorta by ultrasound, analysis of glycated hemoglobin (HbA1c), and follow-up for ≤5 years...

  14. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome in Association with Ruptured Abdominal Aortic Aneurysm in the Endovascular Era: Vigilance Remains Critical

    Directory of Open Access Journals (Sweden)

    Matthew C. Bozeman

    2012-01-01

    In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  15. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  16. Three-dimensional Ultrasound in the Management of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Lowe, C B; Ghulam, Q; Bredahl, K

    2016-01-01

    Three-dimensional (3D) ultrasound is an evolving modality that may have numerous applications in the management of abdominal aortic aneurysms. Many vascular specialists will not be familiar with the different ways in which 3D vascular ultrasound data can be acquired nor how potential applications...

  17. Biomechanical Indices for Rupture Risk Estimation in Abdominal Aortic Aneurysms

    NARCIS (Netherlands)

    Leemans, Eva L.; Willems, Tineke P.; van der Laan, Maarten J.; Slump, Cornelis H.; Zeebregts, Clark J.

    2017-01-01

    Purpose: To review the use of biomechanical indices for the estimation of abdominal aortic aneurysm (AAA) rupture risk, emphasizing their potential use in a clinical setting. Methods: A search of the PubMed, Embase, Scopus, and Compendex databases was made up to June 2015 to identify articles

  18. Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Ikoma, Akira, E-mail: yfb04322@nifty.com; Nakai, Motoki, E-mail: momonga@wakayama-med.ac.jp; Sato, Morio, E-mail: morisato@wakayama-med.ac.jp; Sato, Hirotatsu, E-mail: kuppa1220@yahoo.co.jp; Minamiguchi, Hiroki, E-mail: hiromina4@hotmail.com; Sonomura, Tetsuo, E-mail: sonomura@wakayama-med.ac.jp [Wakayama Medical University, Departments of Radiology (Japan); Nishimura, Yoshiharu, E-mail: nishim-y@wakayama-med.ac.jp; Okamura, Yoshitaka, E-mail: y-ok@wakayama-med.ac.jp [Wakayama Medical University, Thoracic and Cardiovascular Surgery (Japan)

    2016-04-15

    PurposeTo assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR).Materials and MethodsWe performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks.ResultsData were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of <0.638 or ≥0.638, respectively (P = .002).ConclusionPatients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.

  19. Strategy of endovascular versus open repair for patients with clinical diagnosis of ruptured abdominal aortic aneurysm: the IMPROVE RCT.

    Science.gov (United States)

    Ulug, Pinar; Hinchliffe, Robert J; Sweeting, Michael J; Gomes, Manuel; Thompson, Matthew T; Thompson, Simon G; Grieve, Richard J; Ashleigh, Raymond; Greenhalgh, Roger M; Powell, Janet T

    2018-05-01

    Ruptured abdominal aortic aneurysm (AAA) is a common vascular emergency. The mortality from emergency endovascular repair may be much lower than the 40-50% reported for open surgery. To assess whether or not a strategy of endovascular repair compared with open repair reduces 30-day and mid-term mortality (including costs and cost-effectiveness) among patients with a suspected ruptured AAA. Randomised controlled trial, with computer-generated telephone randomisation of participants in a 1 : 1 ratio, using variable block size, stratified by centre and without blinding. Vascular centres in the UK ( n  = 29) and Canada ( n  = 1) between 2009 and 2013. A total of 613 eligible participants (480 men) with a ruptured aneurysm, clinically diagnosed at the trial centre. A total of 316 participants were randomised to the endovascular strategy group (immediate computerised tomography followed by endovascular repair if anatomically suitable or, if not suitable, open repair) and 297 were randomised to the open repair group (computerised tomography optional). The primary outcome measure was 30-day mortality, with 30-day reinterventions, costs and disposal as early secondary outcome measures. Later outcome measures included 1- and 3-year mortality, reinterventions, quality of life (QoL) and cost-effectiveness. The 30-day mortality was 35.4% in the endovascular strategy group and 37.4% in the open repair group [odds ratio (OR) 0.92, 95% confidence interval (CI) 0.66 to 1.28; p  = 0.62, and, after adjustment for age, sex and Hardman index, OR 0.94, 95% CI 0.67 to 1.33]. The endovascular strategy appeared to be more effective in women than in men (interaction test p  = 0.02). More discharges in the endovascular strategy group (94%) than in the open repair group (77%) were directly to home ( p  open repair group, respectively (OR 0.73, 95% CI 0.53 to 1.00; p  = 0.053), with a stronger benefit for the endovascular strategy in the subgroup of 502 participants

  20. Early results after implantation of a new geometric annuloplasty ring for aortic valve repair.

    Science.gov (United States)

    Mazzitelli, Domenico; Nöbauer, Christian; Rankin, J Scott; Badiu, Catalin C; Krane, Markus; Crooke, Philip S; Cohn, William E; Opitz, Anke; Schreiber, Christian; Lange, Rüdiger

    2013-01-01

    Aortic valve repair is associated with fewer long-term valve-related complications as compared with valve replacement, and repair is being performed increasingly. A current problem is the lack of a geometric annuloplasty ring to facilitate reconstruction. This paper describes the first clinical application of such a device designed to permanently restore physiologic annular size and geometry during aortic valve repair. Based on mathematical studies of human cadaver valves, as well as computed tomography angiographic analyses of awake patients with normal valves, a three-dimensional annuloplasty ring has been developed, consisting of low-profile, one-piece titanium construction and Dacron cloth covering. The ring design incorporates 2:3 elliptical base geometry and 10-degree outwardly flaring subcommissural posts. Appropriately sized rings were implanted in 5 patients with severe aortic insufficiency due to annular dilation and anatomic leaflet defects. The rings restored annular geometry and facilitated leaflet repairs in all patients. Each recovered excellent valve function with minimal residual leak. All patients convalesced uneventfully, were discharged within 7 days after surgery, and continue with stable valve function as long as 6 months after implantation. Initial clinical application of a geometric aortic annuloplasty ring was associated with excellent device performance and perhaps better repairs. Further clinical series and patient follow-up should identify potential benefits of the device, including improved applicability and stability of aortic valve repair. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Recognition and treatment of outflow tract stenosis during and after endovascular exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Lu Qingsheng; Jing Zaiping; Zhao Zhiqing; Bao Junmin; Zhao Jun; Feng Xiang; Feng Rui; Huang Sheng

    2003-01-01

    Objective: To study the cognition and treatment of outflow tract stenosis in and after endovascular exclusion for abdominal aortic aneurysm. Methods: From Mar 1997 to Oct 2002, in 136 patients undergoing abdominal aortic aneurysm endovascular exclusion, 8 patients had outflow tract stenosis during the operation, and 3 patients had outflow tract stenosis after operation. The stenosis of 5 patients occurred at the crotch of the graft-stent. PTA was done in 7 patients and stents were placed in stenotic segment in 2 patients. 2 patients were treated with crossover operation. Results: Following up 1 month to 2 years, all patients have no lower limbs ischemia. Conclusions: The diagnosis of outflow tract stenosis during and after abdominal endovascular exclusion for aortic aneurysm must be in time. The treatment should be according to the different causes of stenosis

  2. Ultrasound screening for abdominal aortic aneurysms.

    Science.gov (United States)

    Engelberger, Stephan; Rosso, Raffaele; Sarti, Manuela; Del Grande, Filippo; Canevascini, Reto; van den Berg, Jos C; Prouse, Giorgio; Giovannacci, Luca

    2017-03-21

    This pilot study aimed to assess the feasibility, acceptance and costs of an ultrasound scan screening programme for abdominal aortic aneurysms (AAA) in the elderly male population resident in Canton Ticino, Switzerland. The target population were male patients aged 65-80 years who attended the outpatient clinics of the Lugano Regional Hospital in 2013. The patients showing interest were contacted by phone to verify their eligibility and fix the appointment for the ultrasound scan of the abdominal aorta. Patients with recent examinations suitable for AAA detection were excluded. Aneurysm was defined as an abdominal aorta with sagittal and/or axial diameter  30 mm. Patients' characteristics and study results were presented as descriptive statistics. The chi-squared test was used to compare categorical variables with p rate was 68.3%. A previously unknown AAA was diagnosed in 31 patients (4.2%, 95% confidence interval 2.8-5.9%). Age and area of residence had a statistically significant impact on patient's acceptance rate (p <0.05). The mean cost per screened patient was CHF 88. AAA screening of male patients aged 65-80 years is feasible with limited financial and organisational effort. Adherence might be improved by a larger community-based programme and involvement of general practitioners.

  3. Screening for abdominal aortic aneurysm reduces overall mortality in men. A meta-analysis of the mid- and long-term effects of screening for abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Norman, P

    2008-01-01

    Four randomised controlled trials of screening older men for abdominal aortic aneurysms (AAA) have been completed. A meta-analysis was performed to examine the pooled effects of screening on both mid- and long-term AAA-related and total mortality, and operations for AAA....

  4. Effectiveness of treatment for octogenarians with acute abdominal aortic aneurysm

    NARCIS (Netherlands)

    Scheer, Margot L. J.; Pol, Robert A.; Haveman, Jan Willem; Tielliu, Ignace F. J.; Verhoeven, Eric L. G.; Van den Dungen, Jan J. A. M.; Nijsten, Maarten W.; Zeebregts, Clark J.

    Objective: To investigate whether advanced age may be a reason to refrain from treatment in patients with an acute abdominal aortic aneurysm (AAAA). Methods: This was a retrospective cohort study that took place in a tertiary care university hospital with a 45-bed intensive care unit. Two hundred

  5. Proposta para padronização do relatório de tomografia computadorizada nos aneurismas da aorta abdominal A proposal for standardizing computed tomography reports on abdominal aortic aneurysms

    Directory of Open Access Journals (Sweden)

    Fabiola Goda Torlai

    2006-08-01

    Full Text Available OBJETIVO: Propor um modelo de padronização de relatório para aneurisma da aorta abdominal na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram realizadas, no período de abril a outubro de 2004, entrevistas com integrantes da Disciplina de Cirurgia Vascular da nossa instituição, para elaboração de um modelo de padronização de relatório de tomografia computadorizada para o estudo do aneurisma da aorta abdominal. A partir deste modelo foi elaborado um questionário, enviado a nove outros cirurgiões, todos com experiência em cirurgia da aorta abdominal. O índice de resposta aos questionários foi de 55,5% (5/9. RESULTADOS: Os parâmetros de interesse citados mais freqüentemente para a avaliação dos aneurismas de aorta abdominal foram: diâmetro máximo do colo proximal, extensão do colo proximal até a artéria renal mais baixa, forma do colo proximal, diâmetro máximo do aneurisma e diâmetro das artérias ilíacas comuns. Estes dados permitiram elaborar uma proposta de modelo para padronização de relatório na tomografia computadorizada. CONCLUSÃO: Um modelo para a análise tomográfica padronizada do aneurisma de aorta abdominal permite atender às necessidades dos cirurgiões vasculares para acompanhar a evolução e planejar o tratamento destes pacientes.OBJECTIVE: To propose a model to standardize computed tomography reports on abdominal aortic aneurysms. MATERIALS AND METHODS: Interviews were carried out with members of Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5% (5/9. RESULTS: The most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms

  6. Role of F-18 FDG PET/CT in the management of infected abdominal aortic aneurysm due to salmonella

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Jin; Lee, Jin Soo; Cheong, Moon Hyun; Byun, Sung Su; Hyun, In Young [Inha University College of Medicine, Incheon (Korea, Republic of)

    2007-12-15

    We present a case of infected abdominal aortic aneurysm due to salmonella enteritidis. F-18 FDG PET/CT was performed to diagnosis and during follow-up after antibiotic treatment. Computed tomography (CT) is considered to be the best diagnostic imaging modality in infected aortic lesions. In this case, a combination of CT and FDG PET/CT provided accurate information for the diagnosis of infected abdominal aortic aneurysm. Moreover, FDG PET/CT made an important contribution of monitoring disease activity during antibiotic treatment.

  7. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Allard, Louise; Chayer, Boris; Qin Zhao [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Soulez, Gilles [Department of Radiology, University of Montreal Hospital (CHUM), Quebec H2L 2M1 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Roy, David [Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada); Cloutier, Guy [Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Quebec H2L 2W5 (Canada); Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Quebec H3T 1J4 (Canada); Institute of Biomedical Engineering, University of Montreal, Quebec H3T 1J4 (Canada)

    2013-06-15

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  8. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

    International Nuclear Information System (INIS)

    Allard, Louise; Chayer, Boris; Qin Zhao; Soulez, Gilles; Roy, David; Cloutier, Guy

    2013-01-01

    Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in

  9. Qureshi-5 Catheter for Complex Supra- and Abdominal-Aortic Catheterization.

    Science.gov (United States)

    Qureshi, Adnan I; Xiao, WeiGang; Liu, HongLiang

    2015-10-01

    The use of previously described catheter technique was expanded to complex supra- and abdominal- aortic catheterizations. A new (Qureshi 5) catheter with curved shape at the distal end that has two lumens was used. One of lumens can accommodate a 0.035-inch guide wire and the second lumen can accommodate a 0.018-inch guide wire and terminates at the beginning of the distal curve of the first lumen. The manipulation and engagement of the curved distal end catheter was facilitated by rotation and movement of the J-shaped 0.018-inch guide wire extended coaxial and beyond the distal end of catheter. Subsequently, either contrast was injected or a 0.035-inch guide wire advanced into the target artery. The catheters were used in one patient to perform diagnostic cerebral and abdominal angiography through a 6F introducer sheath placed in the right common femoral artery. The catheterization was complex because of severe tortuosity of arch and descending aorta secondary to kyphosis. The left and right internal carotid arteries and left and right vertebral arteries, left renal artery, and superior mesenteric artery were catheterized in patient (fluoroscopy time 19:46 min). No complications were observed in the patient. The Qureshi-5 catheter was successful in complex supra- and abdominal-aortic catheterizations.

  10. Role of myeloperoxidase in abdominal aortic aneurysm formation: mitigation by taurine.

    Science.gov (United States)

    Kim, Ha Won; Blomkalns, Andra L; Ogbi, Mourad; Thomas, Manesh; Gavrila, Daniel; Neltner, Bonnie S; Cassis, Lisa A; Thompson, Robert W; Weiss, Robert M; Lindower, Paul D; Blanco, Victor M; McCormick, Michael L; Daugherty, Alan; Fu, Xiaoming; Hazen, Stanley L; Stansfield, Brian K; Huo, Yuqing; Fulton, David J; Chatterjee, Tapan; Weintraub, Neal L

    2017-12-01

    Oxidative stress plays a fundamental role in abdominal aortic aneurysm (AAA) formation. Activated polymorphonuclear leukocytes (or neutrophils) are associated with AAA and express myeloperoxidase (MPO), which promotes inflammation, matrix degradation, and other pathological features of AAA, including enhanced oxidative stress through generation of reactive oxygen species. Both plasma and aortic MPO levels are elevated in patients with AAA, but the role of MPO in AAA pathogenesis has, heretofore, never been investigated. Here, we show that MPO gene deletion attenuates AAA formation in two animal models: ANG II infusion in apolipoprotein E-deficient mice and elastase perfusion in C57BL/6 mice. Oral administration of taurine [1% or 4% (wt/vol) in drinking water], an amino acid known to react rapidly with MPO-generated oxidants like hypochlorous acid, also prevented AAA formation in the ANG II and elastase models as well as the CaCl 2 application model of AAA formation while reducing aortic peroxidase activity and aortic protein-bound dityrosine levels, an oxidative cross link formed by MPO. Both MPO gene deletion and taurine supplementation blunted aortic macrophage accumulation, elastin fragmentation, and matrix metalloproteinase activation, key features of AAA pathogenesis. Moreover, MPO gene deletion and taurine administration significantly attenuated the induction of serum amyloid A, which promotes ANG II-induced AAAs. These data implicate MPO in AAA pathogenesis and suggest that studies exploring whether taurine can serve as a potential therapeutic for the prevention or treatment of AAA in patients merit consideration. NEW & NOTEWORTHY Neutrophils are abundant in abdominal aortic aneurysm (AAA), and myeloperoxidase (MPO), prominently expressed in neutrophils, is associated with AAA in humans. This study demonstrates that MPO gene deletion or supplementation with the natural product taurine, which can scavenge MPO-generated oxidants, can prevent AAA formation

  11. Abdominal aortic calcification in dialysis patients: results of the CORD study

    DEFF Research Database (Denmark)

    Honkanen, Eero; Kauppila, Leena; Wikström, Björn

    2008-01-01

    BACKGROUND: Patients with chronic kidney disease stage 5 have a high prevalence of vascular calcification, but the specific anatomical distribution and severity of abdominal aortic calcification (AAC), in contrast to coronary calcification, is less well documented. AAC may be recorded using plain...

  12. Initial Surgical Experience with Aortic Valve Repair: Clinical and Echocardiographic Results

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Due to late complications associated with the use of conventional prosthetic heart valves, several centers have advocated aortic valve repair and/or valve sparing aortic root replacement for patients with aortic valve insufficiency, in order to enhance late survival and minimize adverse postoperative events. Methods: From March/2012 thru March 2015, 37 patients consecutively underwent conservative operations of the aortic valve and/or aortic root. Mean age was 48±16 years and 81% were males. The aortic valve was bicuspid in 54% and tricuspid in the remaining. All were operated with the aid of intraoperative transesophageal echocardiography. Surgical techniques consisted of replacing the aortic root with a Dacron graft whenever it was dilated or aneurysmatic, using either the remodeling or the reimplantation technique, besides correcting leaflet prolapse when present. Patients were sequentially evaluated with clinical and echocardiographic studies and mean follow-up time was 16±5 months. Results: Thirty-day mortality was 2.7%. In addition there were two late deaths, with late survival being 85% (CI 95% - 68%-95% at two years. Two patients were reoperated due to primary structural valve failure. Freedom from reoperation or from primary structural valve failure was 90% (CI 95% - 66%-97% and 91% (CI 95% - 69%-97% at 2 years, respectively. During clinical follow-up up to 3 years, there were no cases of thromboembolism, hemorrhage or endocarditis. Conclusions: Although this represents an initial series, these data demonstrates that aortic valve repair and/or valve sparing aortic root surgery can be performed with satisfactory immediate and short-term results.

  13. Carbon dioxide (CO2) angiography as an option for endovascular abdominal aortic aneurysm repair (EVAR) in patients with chronic kidney disease (CKD).

    Science.gov (United States)

    De Angelis, Chiara; Sardanelli, Francesco; Perego, Matteo; Alì, Marco; Casilli, Francesco; Inglese, Luigi; Mauri, Giovanni

    2017-11-01

    To assess feasibility, efficacy and safety of carbon dioxide (CO 2 ) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with chronic kidney disease (CKD). After Ethical Committee approval, the records of 13 patients (all male, mean age 74.6 ± 8.0 years) with CKD, who underwent EVAR to exclude an abdominal aortic aneurysm (AAA) under CO 2 angiography guidance, were reviewed. The AAA to be excluded had a mean diameter of 52.0 ± 8.0 mm. CO 2 angiography was performed by automatic (n = 7) or hand (n = 6) injection. The endograft was correctly placed and the AAA was excluded in all cases, without any surgical conversions. Two patients (15.4%) had an endoleak: one type-Ia, detected by CO 2 -DSA and effectively treated with prosthesis dilatation; one type-III, detected by CO 2 -DSA, confirmed using 10 ml of ICM, and conservatively managed. In one patient, CO 2 angiograms were considered of too low quality for guiding the procedure and 200 ml of ICM were administered. Overall, 11 patients (84.6%) underwent a successful EVAR under the guidance of the sole CO 2 angiography. No patients suffered from major complications, including those typically CO 2 -related. Two patients suffered from abdominal pain during the procedure secondary to a transient splanchnic perfusion's reduction due to CO 2 , and one patient had a worsening of renal function probably caused by a cholesterol embolization during the procedure. In patients with CKD, EVAR under CO 2 angiography guidance is feasible, effective, and safe.

  14. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Cine phase-contrast MR to assess portal blood flow in a 10-year-old girl with abdominal aortic coarctation: a case report

    International Nuclear Information System (INIS)

    Clark, T.W.I.; Culham, J.A.G.

    1998-01-01

    We report the case of a 10-year-old girl with repaired abdominal aortic coarctation in whom chronic mesenteric ischemia was clinically suspected. Cine phase-contrast magnetic resonance (MR) was used to determine the difference between fasting and postprandial portal blood flow. Fasting flow rates in the portal vein were normal. After a meal, blood flow in the portal vein increased 226 % over the fasting state, showing normal augmentation. To the best of our knowledge, this is the first application of this technique to a pediatric setting. (orig.)

  16. Evaluation of the levels of metalloproteinsase-2 in patients with abdominal aneurysm and abdominal hernias.

    Science.gov (United States)

    Antoszewska, Magdalena

    2013-05-01

    Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant

  17. Low rate of reoperations after acute type A aortic dissection repair from The Nordic Consortium Registry

    DEFF Research Database (Denmark)

    Pan, Emily; Gudbjartsson, Tomas; Ahlsson, Anders

    2018-01-01

    Bakey classification nor the extent of proximal or distal repair predicted freedom from a later reoperation. The only independent risk factor associated with a later proximal reoperation was a history of connective tissue disease. CONCLUSIONS: Type A aortic dissection repair in low- to medium-volume centers......OBJECTIVES: To describe the relationship between the extent of primary aortic repair and the incidence of reoperations after surgery for type A aortic dissection. METHODS: A retrospective cohort of 1159 patients treated for type A aortic dissection at eight Nordic low- to medium......-sized cardiothoracic centers from 2005 to 2014. Data were gathered from patient records and national registries. Patients were separately divided into 3 groups according to the distal anastomoses technique (ascending aorta [n = 791], hemiarch [n = 247], and total arch [n = 66]), and into 2 groups for proximal repair...

  18. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553...... patients, 51 (9%) of whom died within the first 48 hours. Of the 502 patients who survived for more than 48 hours, 109 required ICU therapy for more than 48 hours, whereas 393 patients were in the ICU for less than 48 hours. The incidence of preoperative risk factors was similar for the two groups...... combined failed to permit identification of patients in whom the perioperative survival rate was 0%. Even 20% of patients with multiorgan failure survived for 6 months. Of those patients who needed ICU therapy for more than 48 hours, 41 (38%) were alive at the end of 1988. In response to a questionnaire...

  19. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  20. Low baseline and subsequent higher aortic abdominal aneurysm FDG uptake are associated with poor sac shrinkage post endovascular repair

    Energy Technology Data Exchange (ETDEWEB)

    Marie, Pierre-Yves [CHRU-Nancy, Universite de Lorraine, Nuclear Medecine and Nancyclotep Platform, Nancy (France); INSERM, University of Lorraine, UMR 1116, Nancy (France); CHRU-Nancy, Hopitaux de BRABOIS, Service de Medecine Nucleaire, Vandoeuvre (France); Plissonnier, Didier; Rouer, Martin [CHU-Rouen, Department of Vascular Surgery, Rouen (France); Bravetti, Stephanie [CHRU-Nancy, Universite de Lorraine, Department of Radiology, Nancy (France); Coscas, Raphael [Hopital Ambroise Pare, APHP, Chirurgie Vasculaire, Boulogne-Billancourt (France); Haulon, Stephan [CHU-Lille, Department of Vascular Surgery, Lille (France); Mandry, Damien [CHRU-Nancy, Universite de Lorraine, Department of Radiology, Nancy (France); INSERM, University of Lorraine, UMR 947, Nancy (France); Alsac, Jean-Marc [grid.414093.b, APHP, HEGP, Department of Vascular Surgery, Paris (France); Malikov, Serguei; Settembre, Nicla [CHRU-Nancy, Universite de Lorraine, Vascular Surgery, Nancy (France); Goueffic, Yann [CHU-Nantes, Department of Vascular Surgery, Nantes (France); Morel, Olivier [CHU-Besancon, Department of Nuclear Medecine, Besancon (France); Roch, Veronique [CHRU-Nancy, Universite de Lorraine, Nuclear Medecine and Nancyclotep Platform, Nancy (France); Micard, Emilien [INSERM, University of Lorraine, UMR 947, Nancy (France); INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France); Lamiral, Zohra [INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France); Michel, Jean-Baptiste [INSERM, Bichat, UMR 698, Paris (France); Rossignol, Patrick [INSERM, University of Lorraine, UMR 1116, Nancy (France); INSERM, CHRU-Nancy, Universite de Lorraine, CIC-1433, FCRIN INI-CRCT, Nancy (France)

    2018-04-15

    The growth phases of medically treated abdominal aortic aneurysms (AAA) are frequently associated with an {sup 18}F-fluorodesoxyglucose positron emission tomography (FDG-PET) pattern involving low baseline and subsequent higher FDG uptake. However, the FDG-PET patterns associated with the endovascular aneurysm repair (EVAR) of larger AAA are presently unknown. This study aimed to investigate the relationship between serial AAA FDG uptake measurements, obtained before EVAR and 1 and 6 months post-intervention and subsequent sac shrinkage at 6 months, a well-recognized indicator of successful repair. Thirty-three AAA patients referred for EVAR (maximal diameter: 55.4 ± 6.0 mm, total volume: 205.7 ± 63.0 mL) underwent FDG-PET/computed tomography (CT) before EVAR and at 1 and 6 months thereafter, with the monitoring of AAA volume and of a maximal standardized FDG uptake [SUVmax] averaged between the axial slices encompassing the AAA. Sac shrinkage was highly variable and could be stratified into three terciles: a first tercile in which shrinkage was absent or very limited (0-29 mL) and a third tercile with pronounced shrinkage (56-165 mL). SUVmax values were relatively low at baseline in the 1st tercile (SUVmax: 1.69 ± 0.33), but markedly increased at 6 months (2.42 ± 0.69, p = 0.02 vs. baseline). These SUV max values were by contrast much higher at baseline in the 3rd tercile (SUVmax: 2.53 ± 0.83 p = 0.009 vs. 1st tercile) and stable at 6 months (2.49 ± 0.80), while intermediate results were documented in the 2nd tercile. Lastly, the amount of sac shrinkage, expressed in absolute values or in percentages of baseline AAA volumes, was positively correlated with baseline SUVmax (p = 0.001 for both). A low pre-EVAR FDG uptake and increased AAA FDG uptake at 6 months are associated with reduced sac shrinkage. This sequential FDG-PET pattern is similar to that already shown to accompany growth phases of medically treated AAA. (orig.)

  1. Low baseline and subsequent higher aortic abdominal aneurysm FDG uptake are associated with poor sac shrinkage post endovascular repair

    International Nuclear Information System (INIS)

    Marie, Pierre-Yves; Plissonnier, Didier; Rouer, Martin; Bravetti, Stephanie; Coscas, Raphael; Haulon, Stephan; Mandry, Damien; Alsac, Jean-Marc; Malikov, Serguei; Settembre, Nicla; Goueffic, Yann; Morel, Olivier; Roch, Veronique; Micard, Emilien; Lamiral, Zohra; Michel, Jean-Baptiste; Rossignol, Patrick

    2018-01-01

    The growth phases of medically treated abdominal aortic aneurysms (AAA) are frequently associated with an 18 F-fluorodesoxyglucose positron emission tomography (FDG-PET) pattern involving low baseline and subsequent higher FDG uptake. However, the FDG-PET patterns associated with the endovascular aneurysm repair (EVAR) of larger AAA are presently unknown. This study aimed to investigate the relationship between serial AAA FDG uptake measurements, obtained before EVAR and 1 and 6 months post-intervention and subsequent sac shrinkage at 6 months, a well-recognized indicator of successful repair. Thirty-three AAA patients referred for EVAR (maximal diameter: 55.4 ± 6.0 mm, total volume: 205.7 ± 63.0 mL) underwent FDG-PET/computed tomography (CT) before EVAR and at 1 and 6 months thereafter, with the monitoring of AAA volume and of a maximal standardized FDG uptake [SUVmax] averaged between the axial slices encompassing the AAA. Sac shrinkage was highly variable and could be stratified into three terciles: a first tercile in which shrinkage was absent or very limited (0-29 mL) and a third tercile with pronounced shrinkage (56-165 mL). SUVmax values were relatively low at baseline in the 1st tercile (SUVmax: 1.69 ± 0.33), but markedly increased at 6 months (2.42 ± 0.69, p = 0.02 vs. baseline). These SUV max values were by contrast much higher at baseline in the 3rd tercile (SUVmax: 2.53 ± 0.83 p = 0.009 vs. 1st tercile) and stable at 6 months (2.49 ± 0.80), while intermediate results were documented in the 2nd tercile. Lastly, the amount of sac shrinkage, expressed in absolute values or in percentages of baseline AAA volumes, was positively correlated with baseline SUVmax (p = 0.001 for both). A low pre-EVAR FDG uptake and increased AAA FDG uptake at 6 months are associated with reduced sac shrinkage. This sequential FDG-PET pattern is similar to that already shown to accompany growth phases of medically treated AAA. (orig.)

  2. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-01-01

    Abstract Rationale: To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. Patient concerns: In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. Diagnoses: He was diagnosed with dwarfism complicated with Stanford B aortic dissection. Interventions: After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. Outcomes: The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. Lessons: TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size. PMID:29703033

  3. Strategy for acute type IIIb aortic dissection associated with abdominal-organ malperfusion

    International Nuclear Information System (INIS)

    Ozawa, Masamichi; Uchida, Naomichi; Shibamura, Hidenori; Iwako, Hiroshi

    2006-01-01

    The aim of this study was to evaluate our results of treatment for acute type IIIb aortic dissection associated with malperfusion of abdominal organs, and to consider the therapeutic strategies. Between December 1997 and August 2005, 123 patients with acute type IIIb aortic dissection were treated at our hospital. Of those, 11 patients (8.9%) required emergency treatment for malperfusion of abdominal organ. In our hospital, the indication of emergency treatment for acute type IIIb aortic dissection was any symptom of acute abdomen plus insufficiency of visceral arterial circulation on computed tomography or angiography. All of the 11 patients (100%) had cul-de-sac of a false lumen, 8 (72.7%) had at least one symptom of acute abdomen, and 3 (27.3%) had metabolic acidosis before surgical treatment. In 7 patients of the ''true lumen stenosis type,'' 5 patients who were treated with open stent grafting are alive. The other two patients, who were treated with transluminally placed endovascular stent grafting (TPEG) or with superior mesenteric artery (SMA) bypass, died. Of the 2 ''visceral arterial dissection type'' patient, one was treated with transluminal stenting of the celiac artery and the other was treated with resection of the intestine and ileocolic artery bypass, and both are alive. Two ''mixed type'' patients who were treated with open stent grafting died. The mortality rate of this series was 36.4%. In conclusion, to improve the prognosis of acute type IIIb aortic dissection associated with malperfusion of abdominal organ, it is important that we obtain early diagnosis of organ ischemia caused by cul-de-sac of a false lumen and choose the correct treatment based on understanding of the mechanism of organ ischemia. (author)

  4. Mast Cells in Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Shi, Guo-Ping; Lindholt, Jes Sanddal

    2013-01-01

    Mast cells (MCs) are proinflammatory cells that play important roles in allergic responses, tumor growth, obesity, diabetes, atherosclerosis, and abdominal aortic aneurysm (AAA). Although the presence and function of MCs in atherosclerotic lesions have been thoroughly studied in human specimens......, in primary cultured vascular cells, and in atherosclerosis in animals, their role in AAA was recognized only recently. Via multiple activation pathways, MCs release a spectrum of mediators � including histamine, inflammatory cytokines, chemokines, growth factors, proteoglycans, and proteases � to activate...... neighboring cells, degrade extracellular matrix proteins, process latent bioactive molecules, promote angiogenesis, recruit additional inflammatory cells, and stimulate vascular cell apoptosis. These activities associate closely with medial elastica breakdown, medial smooth-muscle cell loss and thinning...

  5. Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.

    Science.gov (United States)

    Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P

    2008-08-01

    The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.

  6. Reproducibility of ECG-gated Ultrasound Diameter Assessment of Small Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Bredahl, K; Eldrup, N; Meyer, C

    2013-01-01

    No standardised ultrasound procedure to obtain reliable growth estimates for abdominal aortic aneurysms (AAA) is currently available. We investigated the feasibility and reproducibility of a novel approach controlling for a combination of vessel wall delineation and cardiac cycle variation....

  7. Cost-effectiveness analysis of screening for abdominal aortic aneurysms based on five year results from a randomised hospital based mass screening trial

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Fasting, H

    2006-01-01

    The aim of this study was to estimate the cost effectiveness of screening for abdominal aortic aneurysm (AAA).......The aim of this study was to estimate the cost effectiveness of screening for abdominal aortic aneurysm (AAA)....

  8. Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Kauffmann, Claude; Douane, Frédéric; Therasse, Eric; Lessard, Simon; Elkouri, Stephane; Gilbert, Patrick; Beaudoin, Nathalie; Pfister, Marcus; Blair, Jean François; Soulez, Gilles

    2015-04-01

    To evaluate the accuracy and source of errors using a two-dimensional (2D)/three-dimensional (3D) fusion road map for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm. A rigid 2D/3D road map was tested in 16 patients undergoing EVAR. After 3D/3D manual registration of preoperative multidetector computed tomography (CT) and cone beam CT, abdominal aortic aneurysm outlines were overlaid on live fluoroscopy/digital subtraction angiography (DSA). Patient motion was evaluated using bone landmarks. The misregistration of renal and internal iliac arteries were estimated by 3 readers along head-feet and right-left coordinates (z-axis and x-axis, respectively) before and after bone and DSA corrections centered on the lowest renal artery. Iliac deformation was evaluated by comparing centerlines before and during intervention. A score of clinical added value was estimated as high (z-axis 5 mm). Interobserver reproducibility was calculated by the intraclass correlation coefficient. The lowest renal artery misregistration was estimated at x-axis = 10.6 mm ± 11.1 and z-axis = 7.4 mm ± 5.3 before correction and at x-axis = 3.5 mm ± 2.5 and z-axis = 4.6 mm ± 3.7 after bone correction (P = .08), and at 0 after DSA correction (P artery was estimated at x-axis = 2.4 mm ± 2.0 and z-axis = 2.2 mm ± 2.0. Score of clinical added value was low (n = 11), good (n= 0), and high (n= 5) before correction and low (n = 5), good (n = 4), and high (n = 7) after bone correction. Interobserver intraclass correlation coefficient for misregistration measurements was estimated at 0.99. Patient motion before stent graft delivery was estimated at x-axis = 8 mm ± 5.8 and z-axis = 3.0 mm ± 2.7. The internal iliac artery misregistration measurements were estimated at x-axis = 6.1 mm ± 3.5 and z-axis = 5.6 mm ± 4.0, and iliac centerline deformation was estimated at 38.3 mm ± 15.6. Rigid registration is feasible and fairly accurate. Only a partial reduction of vascular

  9. ADAMTS-1 in abdominal aortic aneurysm.

    Directory of Open Access Journals (Sweden)

    Emina Vorkapic

    Full Text Available Extracellular matrix degradation is a hallmark of abdominal aortic aneurysm (AAA. Among proteases that are capable of degrading extracellular matrix are a disintegrin and metalloproteases with thrombospondin motifs (ADAMTS. Pathogenesis of these proteases in AAA has not been investigated until date.Human aneurysmal and control aortas were collected and analyzed with RT-PCR measuring the ADAMTS-1, 4,5,6,8,9,10,13,17 and ADAMTSL-1. Expression of a majority of the investigated ADAMTS members on mRNA level was decreased in aneurysm compared to control aorta. ADAMTS-1 was one of the members that was reduced most. Protein analysis using immunohistochemistry and western blot for localization and expression of ADAMTS-1 revealed that ADAMTS-1 was present predominantly in areas of SMCs and macrophages in aneurysmal aorta and higher expressed in AAA compared to control aortas. The role of ADAMTS-1 in AAA disease was further examined using ADAMTS-1 transgenic/apoE-/- mice with the experimental angiotensin II induced aneurysmal model. Transgenic mice overexpressing ADAMTS-1 showed to be similar to ADAMTS-1 wild type mice pertaining collagen, elastin content and aortic diameter.Several of the ADAMTS members, and especially ADAMTS-1, are down regulated at mRNA level in AAA, due to unknown mechanisms, at the same time ADAMTS-1 protein is induced. The cleavage of its substrates, don't seem to be crucial for the pathogenesis of AAA but rather more important in the development of thoracic aortic aneurysm and atherosclerosis as shown in previous studies.

  10. CT diagnosis of ruptured abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Sacknoff, R.; Novelline, R.A.; Wittenberg, J.; Waltman, A.C.; De Luca, S.A.; Rhea, J.T.; Lawrason, J.N.

    1986-01-01

    Ruptured abdominal aortic aneurysm (AAA) is a life-threatening condition requiring immediate diagnosis and surgery. In a series of 23 consecutive patients scanned by CT for suspected ruptured AAA, CT proved 100% accurate. In seven patients with surgically or pathologically proved ruptured AAA, CT demonstrated a similar distribution of hemorrhage into the perirenal space and to a lesser degree into the anterior and posterior pararenal spaces. The 16 true-negative examinations included ten in patients with unruptured AAA and six in patients with other diseases. The authors conclude that patients in stable condition with suspected ruptured AAA should be examined by CT

  11. Perfusion computed tomography imaging of abdominal aortic aneurysms may be of value for patient specific rupture risk estimation.

    Science.gov (United States)

    Kontopodis, Nikolaos; Galanakis, Nikolaos; Tsetis, Dimitrios; Ioannou, Christos V

    2017-04-01

    Abdominal aortic aneurysm (AAA) continues to pose a significant cause of unexpected mortality in the developed countries with its incidence constantly rising. The indication of elective surgical repair is currently based on the maximum diameter and growth rate criteria which represent an oversimplification of the Law of Laplace stating that the stress exerted in a cylinder or sphere is proportional to its radius. These criteria fail to capture the complex pathophysiology of the aneurismal disease thus often leading to therapeutic inaccuracies (treating large AAAs with a very low actual rupture risk while observing smaller ones with a much greater risk). Aneurysmal disease is mainly a degenerative process leading to loss of structural integrity of the diseased aortic wall which cannot withhold the stresses due to systemic pressurization. Moreover aortic wall degeneration has been shown to be a localized phenomenon and rupture depends on the pointwise comparison of strength and stress rather than a global aortic wall weakening. Ex-vivo mechanical studies have related vessel wall hypoxia to loss of structural endurance and reduced wall strength. Therefore a module to capture in vivo variation of aortic wall blood supply and oxygenation would be of value for the evaluation of AAA rupture risk. Perfusion computed tomography (PCT) imaging represents a novel technique which has been already used to estimate tissue vascularity in several clinical conditions but not aneurismal disease. We hypothesize that PCT could be used as an adjunct tool during AAA diagnostics in order to evaluate aortic wall oxygenation in vivo, therefore providing a possible means to identify weak spots making the lesion amenable to rupture. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  13. A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Roberto Moraes Bastos

    2011-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair. METHODS: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase. RESULTS: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams. CONCLUSION: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

  14. Predictors of outcome after elective endovascular abdominal aortic aneurysm repair and external validation of a risk prediction model.

    Science.gov (United States)

    Wisniowski, Brendan; Barnes, Mary; Jenkins, Jason; Boyne, Nicholas; Kruger, Allan; Walker, Philip J

    2011-09-01

    Endovascular abdominal aortic aneurysm (AAA) repair (EVAR) has been associated with lower operative mortality and morbidity than open surgery but comparable long-term mortality and higher delayed complication and reintervention rates. Attention has therefore been directed to identifying preoperative and operative variables that influence outcomes after EVAR. Risk-prediction models, such as the EVAR Risk Assessment (ERA) model, have also been developed to help surgeons plan EVAR procedures. The aims of this study were (1) to describe outcomes of elective EVAR at the Royal Brisbane and Women's Hospital (RBWH), (2) to identify preoperative and operative variables predictive of outcomes after EVAR, and (3) to externally validate the ERA model. All elective EVAR procedures at the RBWH before July 1, 2009, were reviewed. Descriptive analyses were performed to determine the outcomes. Univariate and multivariate analyses were performed to identify preoperative and operative variables predictive of outcomes after EVAR. Binomial logistic regression analyses were used to externally validate the ERA model. Before July 1, 2009, 197 patients (172 men), who were a mean age of 72.8 years, underwent elective EVAR at the RBWH. Operative mortality was 1.0%. Survival was 81.1% at 3 years and 63.2% at 5 years. Multivariate analysis showed predictors of survival were age (P = .0126), American Society of Anesthesiologists (ASA) score (P = .0180), and chronic obstructive pulmonary disease (P = .0348) at 3 years and age (P = .0103), ASA score (P = .0006), renal failure (P = .0048), and serum creatinine (P = .0022) at 5 years. Aortic branch vessel score was predictive of initial (30-day) type II endoleak (P = .0015). AAA tortuosity was predictive of midterm type I endoleak (P = .0251). Female sex was associated with lower rates of initial clinical success (P = .0406). The ERA model fitted RBWH data well for early death (C statistic = .906), 3-year survival (C statistic = .735), 5-year

  15. Echocardiographic assessment of the aortic root dilatation in adult patients after tetralogy of Fallot repair.

    Science.gov (United States)

    Cruz, Cristina; Pinho, Teresa; Lebreiro, Ana; Silva Cardoso, José; Maciel, Maria Júlia

    2013-06-01

    Transthoracic echocardiography is an important tool after tetralogy of Fallot repair, of which aortic root dilatation is a recognized complication. In this study we aimed to assess its prevalence and potential predictors. We consecutively assessed adult patients by transthoracic echocardiography after tetralogy of Fallot repair, and divided them into two groups based on the maximum internal aortic diameter at the sinuses of Valsalva in parasternal long-axis view: group 1 with aortic root dilatation (≥38 mm) and group 2 without dilatation (de Cardiologia. Published by Elsevier España. All rights reserved.

  16. Preadmission use of renin-angiotensin blockers and rupture of abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Wemmelund, Holger; Høgh, Annette; Hundborg, Heidi H.

    2016-01-01

    PURPOSE: Rupture of abdominal aortic aneurysms (rAAA) is associated with high mortality. Use of angiotensin converting enzyme inhibitors (ACE-inhibitors) and angiotensin receptor blockers (ARBs) has been suggested to reduce the risk of rAAA. This nationwide, combined case-control and follow-up st...

  17. CD1d deficiency inhibits the development of abdominal aortic aneurysms in LDL receptor deficient mice

    NARCIS (Netherlands)

    van Puijvelde, Gijs H. M.; Foks, Amanda C.; van Bochove, Rosemarie E.; Bot, Ilze; Habets, Kim L. L.; de Jager, Saskia C.; ter Borg, Mariëtte N. D.; van Osch, Puck; Boon, Louis; Vos, Mariska; de Waard, Vivian; Kuiper, Johan

    2018-01-01

    An abdominal aortic aneurysm (AAA) is a dilatation of the abdominal aorta leading to serious complications and mostly to death. AAA development is associated with an accumulation of inflammatory cells in the aorta including NKT cells. An important factor in promoting the recruitment of these

  18. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits....

  19. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms : Implications for endograft treatment

    NARCIS (Netherlands)

    Teutelink, A; Rutten, A; Muhs, BE; Olree, M; van Herwaarden, JA; de Vos, AM; Prokop, M; Moll, FL; Verhagen, HJM

    Purpose: To utilize 40-slice electrocardiographically (ECG)-gated cine computed tomographic angiography (CTA) to characterize normal aortic motion during the cardiac cycle at relevant anatomical landmarks in preoperative abdominal aortic aneurysm (AAA) patients. Methods: In 10 consecutive

  20. Improving Results of Elective Abdominal Aortic Aneurysm Repair at a Low-Volume Hospital by Risk-Adjusted Selection of Treatment in the Endovascular Era

    International Nuclear Information System (INIS)

    Wibmer, Andreas; Meyer, Bernhard; Albrecht, Thomas; Buhr, Heinz-Johannes; Kruschewski, Martin

    2009-01-01

    Several studies have observed both higher mortality rates and lower utilization of endovascular aneurysm repair (EVAR) at low-volume centers. This article presents the results of elective abdominal aortic aneurysm (AAA) repair at a low-volume center in the endovascular era and investigates whether postprocedural mortality can be improved by extension of EVAR application also in this setting. This is an 11.6-year retrospective cohort study of 132 patients undergoing elective surgical or endovascular AAA repair at a tertiary care academic hospital between 1997 and July 2008, i.e., a median volume of 12 cases per year. The study was divided into two periods of time according to the respective indications and contraindications for EVAR, which substantially changed in 2005. During period 1, only aneurysms with necks ≥20 mm long and not involving the iliac arteries were treated endoluminally. Beginning in 2005, indication for EVAR was expanded to aortoiliac aneurysms with a minimum neck length of 15 mm. Preoperative risk was assessed by the SVS/AAVS comorbidity score. During the first period (1997-2004) 18.4% (16/87) of all patients received EVAR. By extending anatomical confines and indications for EVAR in 2005, the utilization rate of EVAR increased to 40.0% (18/45) during the second period (2005-July 2008; p = 0.007). Prevalence of preoperative risk factors did not change during the two observation periods. In contrast to period 1, high-risk patients were preferentially treated endoluminally during the second period, resulting in a significantly higher median SVS/AAVS score in the EVAR group (p < 0.001). A significant decrease in median length of stay at the intensive/intermediate care unit (5 vs. 2 days; p = 0.006) and length of in-hospital stay (20 vs. 12.5 days; p < 0.001) was observed during period 2. Overall perioperative mortality was reduced from 6.9% during the first period to 2.2% during the second period (p = 0.256). EVAR mortality was 0%, mortality after

  1. Endovascular Retrieval of Entrapped Elephant Trunk Graft During Complex Hybrid Aortic Arch Repair

    Energy Technology Data Exchange (ETDEWEB)

    Damodharan, Karthikeyan, E-mail: drdkarthik@hotmail.com [Singapore General Hospital, Department of Diagnostic Radiology (Singapore); Chao, Victor T. T., E-mail: victor.chao.t.t@singhealth.com.sg [National Heart Centre, Department of Cardiothoracic Surgery (Singapore); Tay, Kiang Hiong, E-mail: tay.kiang.hiong@singhealth.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore)

    2016-12-15

    Entrapment of the elephant trunk graft within the false lumen is a rare complication of surgical repair of an aortic dissection. This is normally retrieved by emergent open surgery. We describe a technique of endovascular retrieval of the dislodged graft, during hybrid aortic arch repair. The elephant trunk was cannulated through and through from a femoral access and the free end of the wire was snared and retrieved from a brachial access. The wire was externalised from both accesses and was used to reposition the graft into the true lumen using a body flossing technique.

  2. Abdominal aortic aneurysm screening program in Poland.

    Science.gov (United States)

    Jawien, A; Formankiewicz, B; Derezinski, T; Migdalski, A; Brazis, P; Woda, L

    Screening for abdominal aortic aneurysms (AAA) is currently recommended by several vascular societies. In countries where it has been introduced the prevalence of AAAs differed greatly and was mainly related to cigarette smoking. The screening program also had an enormous impact on the decrease of AAA ruptures and reduced mortality rate. These facts have led to the introduction of the first screening program for AAAs in Poland. The aim of the study was to determine the prevalence of AAAs among men aged 60 years and older undergoing ultrasound examination of the abdominal aorta. A single ultrasonography of the abdomen was performed to assess the aorta from the renal arteries to the bifurcation and the diameter of the aorta was measured at its widest point. The cut-off value for determining an aortic aneurysm was set at a diameter of ≥ 30 mm. All ultrasonography measurements were performed by physicians in outpatient departments throughout the Kuyavian-Pomeranian Province. Additionally, each subject had to fill out a questionnaire with demographic data, smoking habits, existing comorbidities and familial occurrence of AAAs. The study was conducted from October 2009 to November 2011. The abdominal aorta ultrasound examinations were carried out in 1556 men aged 60 years and older. The prevalence of AAA in the study population was 6.0 % (94 out of 1556). The average age of the men was 69 years (SD 6 years, range 60-92 years). In the study population 55 % of the men smoked or had smoked and 3 % were aware of the presence of AAAs in family members. There were three risk factors significantly associated with the presence of AAAs: age (p < 0.05), smoking (72.3 % vs 53.9 %, p = 0.004) and family history of AAAs (9.6 % vs 2.7 %, p = 0.017). The prevalence of AAAs among men in Poland is higher than in other European countries and the USA. The screening program for AAAs is an easy and reliable method for detecting early stages of the disease and

  3. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  4. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  5. Ruptured Aortic Aneurysm From Late Type II Endoleak Treated by Transarterial Embolization

    International Nuclear Information System (INIS)

    Gunasekaran, Senthil; Funaki, Brian; Lorenz, Jonathan

    2013-01-01

    Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.

  6. Transthoracic Echocardiography Provides Important Long-Term Prognostic Information in Selected Patients Undergoing Endovascular Abdominal Aortic Repair.

    Science.gov (United States)

    O'Driscoll, Jamie M; Bahia, Sandeep S; Gravina, Angela; Di Fino, Sara; Thompson, Matthew M; Karthikesalingam, Alan; Holt, Peter J E; Sharma, Rajan

    2016-02-01

    The value of performing transthoracic echocardiography (TTE) as part of the clinical assessment of patients awaiting endovascular repair of the abdominal aorta is little evaluated. We aimed to estimate the prognostic importance of information derived from TTE on long-term all-cause mortality in a selected group of patients undergoing endovascular aneurysm repair. This was a retrospective cohort study of 273 consecutive patients selected for endovascular aneurysm repair. All patients included in the analysis underwent TTE before their procedure. Multivariable Cox regression analysis was used to estimate the effect of TTE measures on all-cause mortality. Over a mean follow-up of 3.2±1.5 years, there were 78 deaths with a mean time to death of 1.28±1.16 years. A greater tubular ascending aorta (hazard ratio [HR] 5.6, 95% confidence interval [CI] 2.77-11.33), presence of mitral regurgitation (HR 8.13, 95% CI 4.09-12.16), lower left ventricular ejection fraction (HR 0.96, 95% CI 0.93-0.98), younger age (HR 0.97, 95% CI 0.95-0.99), and presence of diabetes mellitus (HR 1.46, 95% CI 1.24-1.89) were predictors of all-cause mortality. Echocardiography provides important long-term prognostic information in patients undergoing endovascular aneurysm repair. These TTE indices were more important at predicting outcome than standard conventional risk factors in this patient group. A greater tubular ascending aorta, presence of mitral regurgitation, reduced left ventricular ejection fraction, younger age, and diabetes mellitus were independently associated with long-term mortality. © 2016 American Heart Association, Inc.

  7. Risk stratification by pre-operative cardiopulmonary exercise testing improves outcomes following elective abdominal aortic aneurysm surgery: a cohort study.

    Science.gov (United States)

    Goodyear, Stephen J; Yow, Heng; Saedon, Mahmud; Shakespeare, Joanna; Hill, Christopher E; Watson, Duncan; Marshall, Colette; Mahmood, Asif; Higman, Daniel; Imray, Christopher He

    2013-05-19

    In 2009, the NHS evidence adoption center and National Institute for Health and Care Excellence (NICE) published a review of the use of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs). They recommended the development of a risk-assessment tool to help identify AAA patients with greater or lesser risk of operative mortality and to contribute to mortality prediction.A low anaerobic threshold (AT), which is a reliable, objective measure of pre-operative cardiorespiratory fitness, as determined by pre-operative cardiopulmonary exercise testing (CPET) is associated with poor surgical outcomes for major abdominal surgery. We aimed to assess the impact of a CPET-based risk-stratification strategy upon perioperative mortality, length of stay and non-operative costs for elective (open and endovascular) infra-renal AAA patients. A retrospective cohort study was undertaken. Pre-operative CPET-based selection for elective surgical intervention was introduced in 2007. An anonymized cohort of 230 consecutive infra-renal AAA patients (2007 to 2011) was studied. A historical control group of 128 consecutive infra-renal AAA patients (2003 to 2007) was identified for comparison.Comparative analysis of demographic and outcome data for CPET-pass (AT ≥ 11 ml/kg/min), CPET-fail (AT 11 ml/kg/min was associated with reduced perioperative mortality (open cases only), LOS, survival and inpatient costs (open and endovascular repair) for elective infra-renal AAA surgery.

  8. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Lotfi, S., E-mail: shamim.lotfi@kcl.ac.uk; Clough, R. E.; Ali, T. [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom); Salter, R. [Guy' s and St. Thomas' NHS Trust, Interventional Radiology (United Kingdom); Young, C. P. [Guy' s and St. Thomas' NHS Trust, Cardiac Surgery (United Kingdom); Bell, R.; Modarai, B.; Taylor, P., E-mail: peter.taylor@gstt.nhs.uk [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom)

    2013-02-15

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997-2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18-90) years with mean follow-up of 15 (range, 0-61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  9. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    International Nuclear Information System (INIS)

    Lotfi, S.; Clough, R. E.; Ali, T.; Salter, R.; Young, C. P.; Bell, R.; Modarai, B.; Taylor, P.

    2013-01-01

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997–2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18–90) years with mean follow-up of 15 (range, 0–61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  10. Upper gastrointestinal obstruction secondary to aortoduodenal syndrome owing to a noninflammatory abdominal aortic aneurysm.

    LENUS (Irish Health Repository)

    Cahill, Kevin

    2012-01-31

    Aortoduodenal syndrome is a rare complication of an abdominal aortic aneurysm wherein the aneurysm sac obstructs the patient\\'s duodenum. It presents with the symptoms of an upper gastrointestinal tract obstruction and requires surgical intervention to relieve it. Previously, gastric bypass surgery was advocated, but now aortic replacement is the mainstay of treatment. We report a case of a 67-year-old woman whose aortoduodenal syndrome was successfully managed and review the literature on this topic.

  11. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  12. Traumatic abdominal aortic dissection in a 16-month-old child

    International Nuclear Information System (INIS)

    Heck, Josh M.; Bittles, Mark A.

    2009-01-01

    Abdominal aortic injury after blunt trauma is rare in the pediatric population. There have been fewer than 20 reported cases in the literature since 1960, and most were the result of motor vehicle collisions. We report the case of a 16-month-old boy who is the youngest reported patient to sustain this type of injury. We discuss the radiologic findings in multiple imaging modalities, mechanisms, associated injuries and management options. (orig.)

  13. Unplanned return to operating room after endovascular repair of abdominal aortic aneurysm (EVAR) is associated with increased risk of hospital readmission.

    Science.gov (United States)

    Aziz, Faisal; Ferranti, Katelynn; Lehman, Erik B

    2018-04-01

    Objectives Hospital readmissions after surgical operations are considered serious events. Centers for Medicare and Medicaid (CMS) consider surgical readmissions as preventable and hold hospitals responsible for them. Endovascular abdominal aortic aneurysm (EVAR) has become the first line modality of treatment for suitable patients with abdominal aortic aneurysm (AAA). The purpose of this study is to retrospectively review the factors associated with hospital readmission after EVAR. Methods The 2013 EVAR targeted American College of Surgeons (ACS-NSQIP) database and generalized 2013 general and vascular surgery ACS-NSQIP participant use files were used for this study. Patient, diagnosis, and procedure characteristics of patients undergoing EVAR surgery were assessed. Multivariate logistic regression analysis was used to determine independent risk factors for hospital readmission within 30 days after surgery. Results A total of 2277 patients (81% males, 19% females) underwent EVAR operations in the year 2013. Indications for operations included: asymptomatic large diameter (79%), symptomatic (5.7%), rupture without hypotension (4.3%), and rupture with hypotension (2.8%). Among these patients, 178 (7.8%) were readmitted to the hospital within 30 days after surgery. About 53% of all readmissions were within two weeks after the discharge. Risk factors, associated with readmission included: body mass index (per 5-units, OR 1.23, CI 1.06-1.42, p readmission for patients with presence of all these seven factors was 99.9%. Conclusions Readmission after EVAR is a serious occurrence. Various factors predispose a patient at a high risk for readmission. Unplanned return to operating room after EVAR is associated with a 11-fold increase in hospital readmission.

  14. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection: A case report.

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-04-01

    To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. He was diagnosed with dwarfism complicated with Stanford B aortic dissection. After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size.

  15. The Infant with Aortic Arch Hypoplasia and Small Left Heart Structures: Echocardiographic Indices of Mitral and Aortic Hypoplasia Predicting Successful Biventricular Repair.

    Science.gov (United States)

    Plymale, Jennifer M; Frommelt, Peter C; Nugent, Melodee; Simpson, Pippa; Tweddell, James S; Shillingford, Amanda J

    2017-08-01

    In infants with aortic arch hypoplasia and small left-sided cardiac structures, successful biventricular repair is dependent on the adequacy of the left-sided structures. Defining accurate thresholds of echocardiographic indices predictive of successful biventricular repair is paramount to achieving optimal outcomes. We sought to identify pre-operative echocardiographic indices of left heart size that predict intervention-free survival in infants with small left heart structures undergoing primary aortic arch repair to establish biventricular circulation (BVC). Infants ≤2 months undergoing aortic arch repair from 1999 to 2010 with aortic and/or mitral valve hypoplasia, (Z-score ≤-2) were included. Pre-operative and follow-up echocardiograms were reviewed. Primary outcome was successful biventricular circulation (BVC), defined as freedom from death, transplant, or single ventricular conversion at 1 year. Need for catheter based or surgical re-intervention (RI), valve annular growth, and significant late aortic or mitral valve obstruction were additional outcomes. Fifty one of 73 subjects (79%) had successful BVC and were free of RI at 1 year. Seven subjects failed BVC; four of those died. The overall 1 year survival for the cohort was 95%. Fifteen subjects underwent a RI but maintained BVC. In univariate analysis, larger transverse aorta (p = 0.006) and aortic valve (p = 0.02) predicted successful BVC without RI. In CART analysis, the combination of mitral valve (MV) to tricuspid valve (TV) ratio ≤0.66 with an aortic valve (AV) annulus Z-score ≤-3 had the greatest power to predict BVC failure (sensitivity 71%, specificity 94%). In those with successful BVC, the combination of both AV and MV Z-score ≤-2.5 increased the odds of RI (OR 3.8; CI 1.3-11.4). Follow-up of non-RI subjects revealed improvement in AV and MV Z-score (median AV annulus changed over time from -2.34 to 0.04 (p indices. In this complex population, 1 year survival is high, but

  16. Abdominal aortic aneurysm in a premature neonate with disseminated candidiasis: Ultrasound and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Khoss, A.E.; Ponhold, W.; Pollak, A.; Schlemmer, M.; Weninger, M.

    1985-09-01

    When using ultrasound for detection of kidney enlargement, we found an acute abdominal aortic aneurysm secondary to aortitis arising from umbilical artery catheterisation in a premature neonate with systemic candidiasis. Aortography was performed to provide vascular details such as involvement of celiac, renal, iliac and femoral arteries.

  17. Long-term outcomes after immediate aortic repair for acute type A aortic dissection complicated by coma.

    Science.gov (United States)

    Tsukube, Takuro; Haraguchi, Tomonori; Okada, Yasushi; Matsukawa, Ritsu; Kozawa, Shuichi; Ogawa, Kyoichi; Okita, Yutaka

    2014-09-01

    The management of acute type A aortic dissection complicated by coma remains controversial. We previously reported an excellent rate of recovery of consciousness provided aortic repair was performed within 5 hours of the onset of symptoms. This study evaluates the early and long-term outcomes using this approach. Between August 2003 and July 2013, of the 241 patients with acute type A aortic dissection brought to the Japanese Red Cross Kobe Hospital and Hyogo Emergency Medical Center, 30 (12.4%) presented with coma; Glasgow Coma Scale was less than 11 on arrival. Surgery was performed in 186 patients, including 27 (14.5%) who were comatose. Twenty-four comatose patients underwent successful aortic repair immediately (immediate group). Their mean age was 71.0 ± 11.1 years, Glasgow Coma Scale was 6.5 ± 2.4, and prevalence of carotid dissection was 79%. For brain protection, deep hypothermia with antegrade cerebral perfusion was used, and postoperative induced hypothermia was performed. Neurologic evaluations were performed using the Glasgow Coma Scale, National Institutes of Health Stroke Scale, and modified Rankin Scale. In the immediate group, the time from the onset of symptoms to arrival in the operating theater was 222 ± 86 minutes. Hospital mortality was 12.5%. Full recovery of consciousness was achieved in 79% of patients in up to 30 days. Postoperative Glasgow Coma Scale and National Institutes of Health Stroke Scale improved significantly when compared with the preoperative score (P coma were satisfactory. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  18. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    Science.gov (United States)

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  19. Plasma levels of cathepsins L, K, and V and risks of abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lv, Bing-Jie; Lindholt, Jes S; Wang, Jing

    2013-01-01

    Cathepsin L (CatL), cathepsin K (CatK), and cathepsin V (CatV) are potent elastases implicated in human arterial wall remodeling. Whether plasma levels of these cathepsins are altered in patients with abdominal aortic aneurysms (AAAs) remains unknown....

  20. Plasma cytokine levels and risks of abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Liao, Mengyang; Liu, Cong-Lin; Lv, Bing-Jie

    2015-01-01

    BACKGROUND: Abdominal aortic aneurysm (AAA) is characterized by inflammatory cell accumulation in AAA lesions that produce inflammatory cytokines and advance its pathogenesis. Peripheral cytokines may predict the degree or risk of AAA. METHODS AND RESULTS: ELISA determined plasma interleukin-6 (IL6......), IL10, IL17A, IFN-γ, and C-reactive protein (CRP) from 476 AAA patients and 200 controls. AAA patients had lower IL6, IFN-γ, IL10, IL17A, and higher CRP than controls. IL10 correlated positively with IFN-γ, IL17A, or IL6, but not CRP in control or AAA populations. IL10 associated negatively...... with systolic blood pressure, whereas CRP associated positively with diastolic blood pressure and body mass index. CRP was an independent AAA risk factor and correlated positively with aortic diameters before and after adjustments for other risk factors. IFN-γ, IL17A, and CRP correlated positively with cross...

  1. Magnetic Resonance angiography with bolus contrast agent in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Di Cesare, E.; Cerone, G.; Giordano, A.V.; Marsili, L.; Barile, A.; Michelini, O.; Masciocchi, C.; Spartera, C.

    2000-01-01

    Purpose of this paper is to investigate the potentials of 3D breath-hold contrast-enhanced Magnetic Resonance Angiography (MRA) in the diagnosis, follow-up and treatment planning of abdominal aortic aneurysms. Twenty-four patients with infrarenal aortic aneurysm underwent MRA. It was used a 1.5 T unit (GE Horizon, Echospeed 8.2), a phased array surface coil and 3D Fast SPGR T1-weighted sequences acquired on the coronal plane during patient breath-hold and after contrast agent i.v. administration. A bolus-test was done before angiography to optimize imaging delay time. After 3D MRA a Fast-SPGR T1-weighted sequence was acquired on the axial plane. The 3D MRA source images were processed with the MIP algorithm. Qualitative and quantitative analyses were carried out. Helical CT was performed in 6 cases and DSA in 7 cases. Surgery was the reference standard in 15 patients. MRA depicted aneurysm thrombosis in 22 cases, carrefour involvement in 18 cases and iliac arteries involvement in 3 cases. Accessory renal arteries were shown in 4 cases; iliac artery stenosis was associated in 5 cases. There was agreement between MR and Helical CT and DSA findings: surgery confirmed MRA results in 15/15 cases. 3D contrast-enhanced MRA can be considered the method of choice in the follow-up and treatment planning of abdominal aortic aneurysms, because it provides both angiographic and tomographic images: this allows to obtain more information, noninvasively and without the use of ionizing radiations [it

  2. Abdominal aortic aneurysm in a premature neonate with disseminated candidiasis: Ultrasound and angiography

    International Nuclear Information System (INIS)

    Khoss, A.E.; Ponhold, W.; Pollak, A.; Schlemmer, M.; Weninger, M.

    1985-01-01

    When using ultrasound for detection of kidney enlargement, we found an acute abdominal aortic aneurysm secondary to aortitis arising from umbilical artery catheterisation in a premature neonate with systemic candidiasis. Aortography was performed to provide vascular details such as involvement of celiac, renal, iliac and femoral arteries. (orig.)

  3. Nursing cooperation in endovascular aneurysm repair treatment for aortic dissection

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan; Chen Rumei; Xiao Zhanqiang; Qi Youfei

    2014-01-01

    Objective: To summarize the main points of nursing cooperation in endovascular aneurysm repair treatment for aortic dissection. Methods: Preoperative psychological care and the other preparations were carefully conducted. During the operation, the patient's body was correctly placed. Active cooperation with the performance of angiography and close observation during heparinization were carried out. The proper delivery of catheter and stent to the operator was carefully done. Close observation for the patient's vital signs, the renal function and the changes of limb blood supply were made. Results: Under close cooperation of' the operators, nurses, anesthesiologists and technicians, the surgery was successfully accomplished in 35 patients. The monitoring of vital signs during the entire performance of operation was well executed. No surgical instruments delivery error's or surgery failure due to unsuitable cooperation occurred. Conclusion: Perfect preoperative preparation, strict nursing cooperation and team cooperation are the key points to ensure a successful endovascular aneurysm repair for aortic dissection. (authors)

  4. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  5. Vitamins and abdominal aortic aneurysm.

    Science.gov (United States)

    Takagi, Hisato; Umemoto, Takuya

    2017-02-01

    To summarize the association of vitamins (B6, B12, C, D, and E) and abdominal aortic aneurysm (AAA), we reviewed clinical studies with a comprehensive literature research and meta-analytic estimates. To identify all clinical studies evaluating the association of vitamins B6/B12/C/D/E and AAA, databases including MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were searched through April 2015, using Web-based search engines (PubMed and OVID). For each case-control study, data regarding vitamin levels in both the AAA and control groups were used to generate standardized mean differences (SMDs) and 95% confidence intervals (CIs). Pooled analyses of the 4 case-control studies demonstrated significantly lower circulating vitamin B6 levels (SMD, -0.33; 95% CI, -0.55 to -0.11; P=0.003) but non-significantly lower vitamin B12 levels (SMD, -0.42; 95% CI, -1.09 to 0.25; P=0.22) in patients with AAA than subjects without AAA. Pooled analyses of the 2 case-control studies demonstrated significantly lower levels of circulating vitamins C (SMD, -0.71; 95% CI, -1.23 to -0.19; P=0.007) and E (SMD, -1.76; 95% CI, -2.93 to 0.60; P=0.003) in patients with AAA than subjects without AAA. Another pooled analysis of the 3 case-control studies demonstrated significantly lower circulating vitamin D (25-hydroxyvitamin D) levels (SMD, -0.25; 95% CI, -0.50 to -0.01; P=0.04) in patients with AAA than subjects without AAA. In a double-blind controlled trial, 4.0-year treatment with a high-dose folic acid and vitamin B6/B12 multivitamin in kidney transplant recipients did not reduce a rate of AAA repair despite significant reduction in homocysteine level. In another randomized, double-blind, placebo-controlled trial, 5.8-year supplementation with α-tocopherol (vitamin E) had no preventive effect on large AAA among male smokers. In clinical setting, although low circulating vitamins B6/C/D/E (not B12) levels are associated with AAA presence, vitamins B6/B12/E

  6. Abdominal Aortic Dissection and Cold-Intolerance After Whole-Body Cryotherapy: A Case Report.

    Science.gov (United States)

    Cámara-Lemarroy, Carlos R; Azpiri-López, José R; Vázquez-Díaz, Luis A; Galarza-Delgado, Dionicio A

    2017-09-01

    Whole-body cryotherapy (WBC) involves short exposures to air temperatures below -100°C and is purported to enhance recovery after exercise and accelerate rehabilitation after injury. It is generally considered a procedure with few side effects, but there are no large studies that have established its safety profile. We present the case of a 56-year-old patient who developed an abdominal aortic dissection after receiving 15 sessions of WBC. The patient had no other strong risk factors for aortic dissection. Exposure to cold temperatures, including WBC, has multiple hemodynamic effects, including increases in blood pressure, heart rate, and an adrenergic response. We suggest that these changes could act as a trigger for the onset of aortic dissections. This could be the first reported cardiovascular complication associated with WBC.

  7. Computer tomography in refined diagnosis of abdominal aortic aneurysms: comparison of outcomes of radiation therapies Versus surgical and morphological studies of resected abdominal aortic fragments

    International Nuclear Information System (INIS)

    Denisova, L.B.; Platonova, A.G.; Demidov, I.N.; Emel'yanova, L.N.

    1998-01-01

    The results of computed tomography (CT) was compared with ultrasonographic and angiographic finding in 168 patients. All data of radiation diagnosis of abdominal aortic aneurysms (AAA) were compared with those of operations and morphological studies of the resected fragments of the aortic parts changed due to aneurysms. These comparisons provided a detailed characterization of the potentialities of CT performed on a third-generation unit in the presurgical diagnosis of this abnormally. At the same time, detailed XCT finding (semiotics of AAA and their complications) are given. The study shows benefits of the refined AAA by applying routine CT. The paper gives a diagnostic algorithm of using radiation studies (ultrasonography, CT, angiography) in the diagnosis of AAA. Third-generation CT units widely used in clinical practice are shown to provide necessary and complete information on the magnitude of AAA

  8. Long-term effect of cinacalcet hydrochloride on abdominal aortic calcification in patients on hemodialysis with secondary hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Nakayama K

    2013-12-01

    Full Text Available Kazunori Nakayama,1,2 Kazushi Nakao,1,2 Yuji Takatori,1,2 Junko Inoue,1 Shoichirou Kojo,1 Shigeru Akagi,1,2 Masaki Fukushima,2 Jun Wada,1 Hirofumi Makino11Department of Medicine and Clinical Science, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2Shigei Medical Research Hospital, Okayama, JapanBackground: Secondary hyperparathyroidism (SHPT is one of the common complications in dialysis patients, and is associated with increased risk of vascular calcification. The effects of cinacalcet hydrochloride treatment on bone and mineral metabolism have been previously reported, but the benefit of cinacalcet on vascular calcification remains uncertain. The aim of this study was to evaluate the impact of cinacalcet on abdominal aortic calcification in dialysis patients.Subjects and methods: Patients were on maintenance hemodialysis with insufficiently controlled SHPT (intact parathyroid hormone [PTH] >180 pg/mL by conventional therapies. All subjects were initially administered 25 mg cinacalcet daily, with concomitant use of calcitriol analogs. Abdominal aortic calcification was annually evaluated by calculating aortic calcification area index (ACAI using multidetector computed tomography (MDCT, from 12 months before to 36 months after the initiation of cinacalcet therapy.Results: Twenty-three patients were analyzed in this study. The mean age was 59.0±8.7 years, 34.8% were women, and the mean dialysis duration was 163.0±76.0 months. After administration of cinacalcet, serum levels of intact PTH, phosphorus, and calcium significantly decreased, and mean Ca × P values significantly decreased from 67.4±7.9 mg2/dL2 to 52±7.7 mg2/dL2. Although the ACAI value did not decrease during the observation period, the increase in ACAI between 24 months and 36 months after cinacalcet administration was significantly suppressed.Conclusion: Long-term administration of cinacalcet was associated with reduced progression of

  9. Beneficial effect of statins on total mortality in abdominal aortic aneurysm (AAA) repair.

    Science.gov (United States)

    Mathisen, Sven Ross; Abdelnoor, Michael

    2017-10-01

    In this single center, retrospective cohort study we wished to compare early and total mortality for all patients treated for abdominal aortic aneurysms (AAA) with open surgery who were taking statins compared to those who were not. A cohort of 640 patients with AAA was treated with open surgery between 1999 and 2012. Patients were consecutively recruited from a source population of 390,000; 21.3% were female, and the median age was 73 years. The median follow-up was 3.93 years, with an interquartile range of 1.79-6.58 years. The total follow-up was 2855 patient-years. An explanatory strategy was used. The propensity score (PS) was implemented to control for selection bias and confounders. The crude effect of statin use showed a 78% reduction of the 30-day mortality. A stratified analysis using the Mantel-Haenszel method on quintiles of the PS gave an adjusted effect of the odds ratio equal to 0.43 (95% CI: 0.18-0.96), indicating a 57% reduction of the 30-day mortality for statin users. The adjusted rate ratio was 0.62 (95% CI: 0.45-0.83), indicating a reduction of long-term mortality of 38% for statin users compared to non-users for a median follow-up of 3.93 years. This retrospective cohort study showed a significant beneficial effect of statin use on early and long-term survival for patients treated with open surgery. To be conclusive, our results need to be replicated by a randomized clinical trial.

  10. Psoas muscle hematoma secondary to a ruptured abdominal aortic aneurysm: case report

    International Nuclear Information System (INIS)

    Cumming, M.J.; Hall, A.J.; Burbridge, B.E.

    2000-01-01

    The diagnosis of a ruptured abdominal aortic aneurysm (RAAA) is usually made on the basis of the classic clinical presentation of hypotension, abdominal or back pain, and a pulsating abdominal mass. However, given the large differential diagnosis for abdominal or back pain, the diagnosis can be elusive in a stable patient. The importance of a rapid diagnosis of a RAAA is emphasized by the 32%-70% operative mortality rate and the 77%-94% overall mortality rate. The case reported here demonstrates unusual clinical and radiological findings in a patient with a RAAA. The patient presented with back pain and a progressive radiculopathy in the L4 distribution. The diagnosis of RAAA was delayed 6 weeks because of the investigation of a suspected nerve root entrapment. Consecutive computed tomographic (CT) imaging over a 6-day period showed the evolution of a psoas muscle hematoma secondary to a RAAA. This case emphasizes the importance of considering a RAAA in elderly patients with a prolonged history of back pain. (author)

  11. Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm.

    Science.gov (United States)

    Drury, D; Michaels, J A; Jones, L; Ayiku, L

    2005-08-01

    Conventional management of abdominal aortic aneurysm (AAA) is by open repair and is associated with a mortality rate of 2-6 per cent. Endovascular aneurysm repair (EVAR) is an alternative technique first introduced in 1991. A systematic review was undertaken of the evidence for the safety and efficacy of elective EVAR in the management of asymptomatic infrarenal AAA. Thirteen electronic bibliographical databases were searched, covering biomedical, health-related, science and social science literature. Outcomes were assessed with respect to efficacy (successful deployment, technical success, conversion rates and secondary intervention rates) and safety (30-day mortality rate, procedure morbidity rates and technical issues-endoleaks, graft thrombosis, stenosis and migration). Of 606 reports identified, 61 met the inclusion criteria (three randomized and 15 non-randomized controlled trials, and 43 uncontrolled studies). There were 29 059 participants in total; 19,804 underwent EVAR. Deployment was successful in 97.6 per cent of cases. Technical success (complete aneurysm exclusion) was 81.9 per cent at discharge and 88.8 per cent at 30 days. Secondary intervention to treat endoleak or maintain graft patency was required in 16.2 per cent of patients. Mean stay in the intensive care unit and mean hospital stay were significantly shorter following EVAR. The 30-day mortality rate for EVAR was 1.6 per cent (randomized controlled trials) and 2.0 per cent in nonrandomized trials and case series. Technical complications comprised stent migration (4.0 per cent), graft limb thrombosis (3.9 per cent), endoleak (type I, 6.8 per cent; type II, 10.3 per cent; type III, 4.2 per cent) and access artery injury (4.8 per cent). EVAR is technically effective and safe, with lower short-term morbidity and mortality rates than open surgery. However, there is a need for extended follow-up as the long-term success of EVAR in preventing aneurysm-related deaths is not yet known.

  12. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    OpenAIRE

    Mustafa Zakkar; Mustafa Zakkar; Vito Domanico Bruno; Alexandru Ciprian Visan; Stephanie Curtis; Gianni Angelini; Emmanuel Lansac; Serban Stoica

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population...

  13. Randomized double-blind controlled trial of roxithromycin for prevention of abdominal aortic aneurysm expansion

    DEFF Research Database (Denmark)

    Vammen, Sten; Lindholt, Jes Sanddal; Ostergaard, L

    2001-01-01

    Macrolide treatment has been reported to lower the risk of recurrent ischaemic heart disease. The influence of macrolides on the expansion rate of abdominal aortic aneurysms (AAAs) remains unknown. The aim was to investigate the effect of roxithromycin on the expansion rate of small AAAs....

  14. Medical image of the week: massive abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Larson M

    2016-07-01

    Full Text Available No abstract available. Article truncated at 150 words. An 88 year-old presented to the emergency department with left flank and lower back pain as well as lower abdominal fullness. The fullness had started 2 days prior, but the left flank pain acutely started in the early morning before presenting. He had a history of unmedicated hypertension, hyperlipidemia, and mild vertigo. His review of systems was positive for chills and difficulty urinating but no hematuria. He was a non-smoker, and had undergone orthopedic surgeries but had otherwise avoided emergent hospitalizations. On exam, vitals were unremarkable; there was no flank nor costovertebral angle tenderness; however, a midline pulsatile mass was present. An initial non-contrast CT abdomen/pelvis revealed a massive abdominal aortic aneurysm (AAA, Figure 1. Follow-up CT angiogram of the AAA can be seen in Figure 2. Upon further questioning, he had undergone a research study some 30 years earlier involving ultrasound to screen for AAA and was told he ...

  15. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  16. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  17. An Abdominal Aortic Aneurysm, Intramural Thrombus and Moderate Leak in an Asian Man Presenting with Acute Gastroenteritis

    Directory of Open Access Journals (Sweden)

    Abdalla Khalil

    2017-11-01

    Full Text Available Introduction: Missing a leaking abdominal aortic aneurysm (AAA is common in medical practice because few at-risk patients have a history of AAA and many have an unusual presentation. Background: AAA is less common among Asians than white Caucasians of the same age. Our patient had no significant risk factors apart from age and sex and had an unusual presentation. Patient and Methods: A 67-year-old Asian man presented to the emergency room (ER with a 1-day history of nausea, vomiting, diarrhoea, fever and abdominal pain. He was febrile, dehydrated. and had marked tenderness at the right iliac fossa. Laboratory findings suggested bacterial gastroenteritis but this did not explain the localized tenderness at the right iliac fossa. Result and Discussion: A CT scan of the abdomen revealed an AAA arising above the origins of the renal arteries, an intramural thrombus, a retroperitoneal haematoma and a leak extending to the right iliac fossa. The patient was transferred to another hospital and underwent exploratory laparotomy, surgical repair of the aneurysm, and aortobi-iliac grafting with removal of the thrombus. The patient was discharged in good shape 3 weeks after surgery. Without the CT scan of the abdomen, the AAA could have been missed and the patient treated for severe gastroenteritis.

  18. Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm.

    Science.gov (United States)

    Wang, Yufei; Joannic, David; Delassus, Patrick; Lalande, Alain; Juillion, Patrick; Fontaine, Jean-François

    2015-04-13

    The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Daily diurnal variation in admissions for ruptured abdominal aortic aneurysms.

    LENUS (Irish Health Repository)

    Killeen, Shane

    2012-02-03

    BACKGROUND: Many vascular events, such as myocardial infarction and cerebrovascular accident, demonstrate a circadian pattern of presentation. Blood pressure is intimately related to these pathologies and is the one physiological variable consistently associated with abdominal aortic aneurysm rupture. It also demonstrates a diurnal variation. The purpose of this study was to determine if rupture of an abdominal aortic aneurysm (RAAA) exhibits a diurnal variation. METHODS: A retrospective cohort-based study was performed to determine the timing of presentation of RAAA to the vascular unit of Cork University Hospital over a 15-year period. Time of admission, symptom onset, and co-morbidities such as hypertension were noted. Fournier\\'s analysis and chi-squared analysis were performed. To ameliorate possible confounding factors, patients admitted with perforated peptic ulcers were examined in the same manner. RESULTS: A total of 148 cases of RAAA were identified, with a male preponderance (71.7% [124] male versus 29.3% [44] female patients) and a mean age of 74.4 +\\/- 7.2 years at presentation. 70.9% (105) were known to have hypertension, 52.2% (77) were current smokers, and 46.8% (69) were being treated for chronic obstructive airway disease (COAD). Time of symptom onset was recorded in 88.5% (131) of patients. There was a marked early morning peak in RAAA admissions, with the highest number of RAAA being admitted between 08.00 and 09.59. A second, smaller peak was observed at 14.00-15.59. These findings were suggestive of diurnal variation. [chi(2) =16.75, p < 0.003]. Some 40% (59) of patients were admitted between 00.00 and 06.00, an incidence significantly higher than for other time periods (06.00-12.00, 12.00-18.00, and 18.00-24.00) [chi(2) = 18.72; df = 3; p < 0.0003]. A significantly higher number of patients admitted between 00.00 and 06.00 were known hypertensives (chi(2) = 7.94; p < 0.05). CONCLUSIONS: The findings of this study suggest a distinct

  20. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Impact of abdominal aortic aneurysm screening on quality of life

    OpenAIRE

    Bath, M. F.; Sidloff, D.; Saratzis, A.; Bown, M. J.

    2018-01-01

    Background Screening for abdominal aortic aneurysm (AAA) is known to reduce AAA‐related mortality; however, the psychological impact of population AAA screening is unclear. The aim was to assess the impact of AAA diagnosis on quality of life (QoL) using data from an established AAA screening programme. Methods Mental and physical QoL scores for men diagnosed with AAA through participation in the English and Welsh AAA screening programmes were compared with no‐AAA controls. Participants were i...

  2. Progressive Supranuclear Palsy-like Syndrome After Aortic Aneurysm Repair: A Case Series

    Directory of Open Access Journals (Sweden)

    Sirisha Nandipati

    2013-12-01

    Full Text Available The syndrome of progressive supranuclear palsy‐like syndrome is a rare complication of ascending aortic aneurysm repair. We report two patients with videos and present a table of prior reported cases. To our knowledge there is no previously published video of this syndrome. The suspected mechanism is brainstem injury though neuroimaging is often negative for an associated infarct. We hope our report will increase recognition of this syndrome after aortic surgery, especially in patients with visual complaints.

  3. The effect of transluminal stent-graft placement on blood flow of abdominal branch vessels in type B aortic dissection

    International Nuclear Information System (INIS)

    Huang Lianjun; Yang Jian; Yu Feicheng; Sun Lizhong; Zhu Junming; Zhang Yan; Jiang Shiliang

    2005-01-01

    Objective: To evaluate the effect of TSGP on blood flow of abdominal branch vessels of Type B dissection. Methods: Thirty-five patients with type B aortic dissection underwent TSGP. The blood flow of abdominal branch vessels was analyzed via EBCT, MRI, and DSA before and after procedure. Results: A total of 140 important vessels from abdominal aorta in 35 patients, including celiac artery, SMA, right and left renal arteries were analyzed via EBCT, MRI, and DSA. 58 branches were affected by dissection, of which 14 (10% ) were dynamic impairment; and 44 (31.4%) were static impairment. After TSGP, the blood flow of impaired branches all showed improvement at different degrees, no post-operative ischemic complications occurred. Conclusion: TSGP could improve the blood flow immediately not only the dynamic but also the static ischemia of abdominal aorta branch vessels caused by type B aortic dissection. Further study is still need to observe the mid-term and long-term effect of TSGP. (authors)

  4. Serum angiotensin-converting enzyme 2 is an independent risk factor for in-hospital mortality following open surgical repair of ruptured abdominal aortic aneurysm

    Science.gov (United States)

    Nie, Wanpin; Wang, Yan; Yao, Kai; Wang, Zheng; Wu, Hao

    2016-01-01

    Open surgical repair (OSR) is a conventional surgical method used in the repair a ruptured abdominal aortic aneurysm (AAA); however, OSR results in high perioperative mortality rates. The level of serum angiotensin-converting enzyme 2 (ACE2) has been reported to be an independent risk factor for postoperative in-hospital mortality following major cardiopulmonary surgery. In the present study, the association of serum ACE2 levels with postoperative in-hospital mortality was investigated in patients undergoing OSR for ruptured AAA. The study enrolled 84 consecutive patients underwent OSR for ruptured AAA and were subsequently treated in the intensive care unit. Patients who succumbed postoperatively during hospitalization were defined as non-survivors. Serum ACE2 levels were measured in all patients prior to and following the surgery using ELISA kits. The results indicated that non-survivors showed significantly lower mean preoperative and postoperative serum ACE2 levels when compared with those in survivors. Multivariate logistic regression analysis also showed that, subsequent to adjusting for potential confounders, the serum ACE2 level on preoperative day 1 showed a significant negative association with the postoperative in-hospital mortality. This was confirmed by multivariate hazard ratio analysis, which showed that, subsequent to adjusting for the various potential confounders, the risk of postoperative in-hospital mortality remained significantly higher in the two lowest serum ACE2 level quartiles compared with that in the highest quartile on preoperative day 1. In conclusion, the present study provided the first evidence supporting that the serum ACE2 level is an independent risk factor for the in-hospital mortality following OSR for ruptured AAA. Furthermore, low serum ACE2 levels on preoperative day 1 were found to be associated with increased postoperative in-hospital mortality. Therefore, the serum ACE2 level on preoperative day 1 may be a potential

  5. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    Directory of Open Access Journals (Sweden)

    Mustafa Zakkar

    2018-03-01

    Full Text Available Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  6. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    Science.gov (United States)

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  7. Osteomyelitis and Discitis Following Translumbar Repair of a Type II Endoleak

    Energy Technology Data Exchange (ETDEWEB)

    Sella, David M., E-mail: Sella.david@mayo.edu; Frey, Gregory T., E-mail: Frey.gregory@mayo.edu; Giesbrandt, Kirk, E-mail: giesbrandt.kirk@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-03-15

    Here we present the case of an 80-year-old man who developed a type II endoleak following endovascular abdominal aortic aneurysm repair. Initial attempts at treating the endoleak via a transarterial approach were unsuccessful; therefore the patient underwent percutaneous translumbar endoleak embolization. Approximately 1 month following the translumbar procedure, he developed back pain, with subsequent workup revealing osteomyelitis and discitis as a complication following repair via the translumbar approach.

  8. Endovascular repair of traumatic thoracic aortic tears.

    Science.gov (United States)

    Mansour, M Ashraf; Kirk, Jeffrey S; Cuff, Robert F; Banegas, Shonda L; Ambrosi, Gavin M; Liao, Timothy H; Chambers, Christopher M; Wong, Peter Y; Heiser, John C

    2012-03-01

    Patients with thoracic aorta injuries (TAI) present a unique challenge. The purpose of this study was to review the outcomes of thoracic endovascular aortic repair (TEVAR) in patients with TAI. A retrospective chart review of all patients admitted for TEVAR for trauma was performed. In a 5-year period, 19 patients (6 women and 13 men; average age, 42 y) were admitted to our trauma center with TAI. Mechanism of injury was a motor vehicle crash in 12 patients, motorcycle crash in 2 patients, automobile-pedestrian accident in 2 patients, 1 fall, 1 crush injury, and 1 stab wound to the back. A thoracic endograft was used in 6 patients and proximal aortic cuffs were used in 13 patients (68%). One patient (5%) died. There were no strokes, myocardial infarctions, paraplegia, or renal failure. TEVAR for TAI appears to be a safe option for patients with multiple injuries. TEVAR in young patients is still controversial because long-term endograft behavior is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. A Radiographic Study on the Associations of Age and Prevalence of Vertebral Fractures with Abdominal Aortic Calcification in Japanese Postmenopausal Women and Men

    Directory of Open Access Journals (Sweden)

    Jun Iwamoto

    2010-01-01

    Full Text Available The purpose of the present study was to determine the associations of age and history of non- and low-traumatic fractures with the severity of abdominal aortic calcification in Japanese postmenopausal women and men. Four hundred and one Japanese persons (24 men and 377 postmenopausal women, mean age: 73.8 years for whom thoracic and lumbar spine radiographs had been obtained to evaluate their posture prior to patient participation in a fall-prevention exercise program were enrolled. The associations of sex, age, history of hip fracture, prevalence of vertebral fracture, and spondylosis grade (the Nathan degree with the severity of abdominal aortic calcification (length of calcification, as evaluated according to the number of vertebral bodies were analyzed. Nine subjects (2.2% had a history of hip fracture, and 221 (55.1% had at least one prevalent vertebral fracture. Two hundred and sixty-seven subjects (66.6% had first-degree spondylosis. Age and the number of prevalent vertebral fractures, but not sex, history of hip fracture, or spondylosis grade, were significantly associated with the severity of abdominal aortic calcification. The present study confirmed that age and the number of vertebral fractures were associated with the severity of abdominal aortic calcification in Japanese postmenopausal women and men.

  10. Neurological Complications Following Endoluminal Repair of Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Morales, J. P.; Taylor, P. R.; Bell, R. E.; Chan, Y. C.; Sabharwal, T.; Carrell, T. W. G.; Reidy, J. F.

    2007-01-01

    Open surgery for thoracic aortic disease is associated with significant morbidity and the reported rates for paraplegia and stroke are 3%-19% and 6%-11%, respectively. Spinal cord ischemia and stroke have also been reported following endoluminal repair. This study reviews the incidence of paraplegia and stroke in a series of 186 patients treated with thoracic stent grafts. From July 1997 to September 2006, 186 patients (125 men) underwent endoluminal repair of thoracic aortic pathology. Mean age was 71 years (range, 17-90 years). One hundred twenty-eight patients were treated electively and 58 patients had urgent procedures. Anesthesia was epidural in 131, general in 50, and local in 5 patients. Seven patients developed paraplegia (3.8%; two urgent and five elective). All occurred in-hospital apart from one associated with severe hypotension after a myocardial infarction at 3 weeks. Four of these recovered with cerebrospinal fluid (CSF) drainage. One patient with paraplegia died and two had permanent neurological deficit. The rate of permanent paraplegia and death was 1.6%. There were seven strokes (3.8%; four urgent and three elective). Three patients made a complete recovery, one had permanent expressive dysphasia, and three died. The rate of permanent stroke and death was 2.1%. Endoluminal treatment of thoracic aortic disease is an attractive alternative to open surgery; however, there is still a risk of paraplegia and stroke. Permanent neurological deficits and death occurred in 3.7% of the patients in this series. We conclude that prompt recognition of paraplegia and immediate insertion of a CSF drain can be an effective way of recovering spinal cord function and improving the prognosis

  11. Relationships between activators and inhibitors of plasminogen, and the progression of small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Jørgensen, B; Shi, G-P

    2003-01-01

    plasmin is a common activator of the known proteolytic systems involved in the aneurysmal degradation, and is reported to be associated with the expansion of abdominal aortic aneurysms (AAA). The aim of this study was to study the activating pathways of plasminogen as predictors of the progression...

  12. Ruptured tuberculous false aneurysm of the abdominal aorta: a case report.

    Science.gov (United States)

    Mechchat, Alae; Lekehal, Brahim; Mesnaoui, Abbes; Ammar, Fannid; Bensaid, Younes

    2011-01-01

    Tuberculous false aneurysm of the aorta is rare and has an unpredictable complication of aneurysm rupture. We report a case of a 32-year old woman who was referred to the Department of Vascular Surgery, Avicenne Hospital for severe abdominal pain. Chest x-ray revealed miliary tuberculosis. Contrast enhanced computed tomography (CT) scan showed a false aortic aneurysm involving the juxtarenal aorta. Antituberculous treatment was started because of high presumption of tuberculosis. Five days later, the patient presented with symptoms of aneurysm rupture. She underwent an emergency a surgical resection of the aneurysm with repair of the aortic wall defect by a Dacron Silver patch. The histopathologic examination of the aortic wall showed features of tuberculosis.

  13. Fluid, solid and fluid-structure interaction simulations on patient-based abdominal aortic aneurysm models.

    Science.gov (United States)

    Kelly, Sinead; O'Rourke, Malachy

    2012-04-01

    This article describes the use of fluid, solid and fluid-structure interaction simulations on three patient-based abdominal aortic aneurysm geometries. All simulations were carried out using OpenFOAM, which uses the finite volume method to solve both fluid and solid equations. Initially a fluid-only simulation was carried out on a single patient-based geometry and results from this simulation were compared with experimental results. There was good qualitative and quantitative agreement between the experimental and numerical results, suggesting that OpenFOAM is capable of predicting the main features of unsteady flow through a complex patient-based abdominal aortic aneurysm geometry. The intraluminal thrombus and arterial wall were then included, and solid stress and fluid-structure interaction simulations were performed on this, and two other patient-based abdominal aortic aneurysm geometries. It was found that the solid stress simulations resulted in an under-estimation of the maximum stress by up to 5.9% when compared with the fluid-structure interaction simulations. In the fluid-structure interaction simulations, flow induced pressure within the aneurysm was found to be up to 4.8% higher than the value of peak systolic pressure imposed in the solid stress simulations, which is likely to be the cause of the variation in the stress results. In comparing the results from the initial fluid-only simulation with results from the fluid-structure interaction simulation on the same patient, it was found that wall shear stress values varied by up to 35% between the two simulation methods. It was concluded that solid stress simulations are adequate to predict the maximum stress in an aneurysm wall, while fluid-structure interaction simulations should be performed if accurate prediction of the fluid wall shear stress is necessary. Therefore, the decision to perform fluid-structure interaction simulations should be based on the particular variables of interest in a given

  14. Chronic Contained Rupture of an Abdominal Aortic Aneurysm: From Diagnosis to Endovascular Resolution

    International Nuclear Information System (INIS)

    Gandini, Roberto; Chiocchi, Marcello; Maresca, Luciano; Pipitone, Vincenzo; Messina, Massimo; Simonetti, Giovanni

    2008-01-01

    A male patient, 69 years old, presented with fever, leucocytosis, and persistent low back pain; he also had an abdominal aortic aneurysm (AAA), as previously diagnosed by Doppler UltraSound (US), and was admitted to our hospital. On multislice computed tomography (msCT), a large abdominal mass having no definite border and involving the aorta and both of the psoas muscles was seen. This mass involved the forth-lumbar vertebra with lysis, thus simulating AAA rupture into a paraspinal collection; it was initially considered a paraspinal abscess. After magnetic resonance imaging examination and culture of the fluid aspirated from the mass, no infective organisms were found; therefore, a diagnosisof chronically contained AAA rupture was made, and an aortic endoprosthesis was subsequently implanted. The patient was discharged with decreased lumbar pain. At 12-month follow-up, no evidence of leakage was observed. To our knowledge, this is the first case of endoprosthesis implantation in a patient, who was a poor candidate for surgical intervention due to renal failure, leucocytosis and high fever, having a chronically contained AAA ruptured simulatingspodilodiscitis abscess. Appropriate diagnosis and therapy resolved potentially crippling pathology and avoided surgical graft-related complications.

  15. Preliminary ten year results from a randomised single centre mass screening trial for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Juul, Søren; Fasting, H

    2006-01-01

    At present, several regions and countries are considering screening for abdominal aortic aneurysm (AAA). However, The Chichester Aneurysms Screening Trial has reported poor long term benefit of screening for AAA. We therefore supplement previously published data with a preliminary analysis...

  16. Late complications in patients after repair of aortic coarctation: implications for management

    NARCIS (Netherlands)

    Vriend, Joris W. J.; Mulder, Barbara J. M.

    2005-01-01

    Survival of patients with aortic coarctation has dramatically improved after surgical repair became available and the number of patients who were operated and reach adulthood is steadily increasing. However, life expectancy is still not as normal as in unaffected peers. Cardiovascular complications

  17. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    International Nuclear Information System (INIS)

    Ilic, Nikola; Davidovic, Lazar; Koncar, Igor; Dragas, Marko; Markovic, Miroslav; Colic, Momcilo; Cinara, Ilijas

    2011-01-01

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

  18. Combined laparoscopic and open technique for repair of congenital abdominal hernia: A case report of prune belly syndrome.

    Science.gov (United States)

    Ye, Qinghuang; Chen, Yan; Zhu, Jinhui; Wang, Yuedong

    2017-10-01

    Prune belly syndrome (PBS) is a rare congenital disorder among adults, and the way for repairing abdominal wall musculature has no unified standard. We described combining laparoscopic and open technique in an adult male who presented with PBS. Physical examination and radiological imaging verified the case of PBS. The deficiency of abdominal wall musculature was repaired by combining laparoscopic and open technique using a double-deck complex patch. The patient successfully underwent abdominal wall repair by combining laparoscopic and open technique. Postoperative recovery was uneventful, and improvement in symptom was significant in follow-up after 3, 6, 12, and 24 months. Combining laparoscopic and open technique for repair of deficiency of abdominal wall musculature in PBS was an exploratory way to improve life quality.

  19. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Increased galectin-3 levels are associated with abdominal aortic aneurysm progression and inhibition of galectin-3 decreases elastase-induced AAA development.

    Science.gov (United States)

    Fernandez-García, Carlos-Ernesto; Tarin, Carlos; Roldan-Montero, Raquel; Martinez-Lopez, Diego; Torres-Fonseca, Monica; Lindhot, Jes S; Vega de Ceniga, Melina; Egido, Jesus; Lopez-Andres, Natalia; Blanco-Colio, Luis-Miguel; Martín-Ventura, Jose-Luis

    2017-11-15

    Abdominal aortic aneurysm (AAA) evolution is unpredictable and no specific treatment exists for AAA, except surgery to prevent aortic rupture. Galectin-3 has been previously associated with CVD, but its potential role in AAA has not been addressed. Galectin-3 levels were increased in the plasma of AAA patients ( n =225) compared with the control group ( n =100). In addition, galectin-3 concentrations were associated with the need for surgical repair, independently of potential confounding factors. Galectin-3 mRNA and protein expression were increased in human AAA samples compared with healthy aortas. Experimental AAA in mice was induced via aortic elastase perfusion. Mice were treated intravenously with the galectin-3 inhibitor modified citrus pectin (MCP, 10 mg/kg, every other day) or saline. Similar to humans, galectin-3 serum and aortic mRNA levels were also increased in elastase-induced AAA mice compared with control mice. Mice treated with MCP showed decreased aortic dilation, as well as elastin degradation, vascular smooth muscle cell (VSMC) loss, and macrophage content at day 14 postelastase perfusion compared with control mice. The underlying mechanism(s) of the protective effect of MCP was associated with a decrease in galectin-3 and cytokine (mainly CCL5) mRNA and protein expression. Interestingly, galectin-3 induced CCL5 expression by a mechanism involving STAT3 activation in VSMC. Accordingly, MCP treatment decreased STAT3 phosphorylation in elastase-induced AAA. In conclusion, increased galectin-3 levels are associated with AAA progression, while galectin-3 inhibition decreased experimental AAA development. Our data suggest the potential role of galectin-3 as a therapeutic target in AAA. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  1. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  2. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  3. Spinal cord ischemia after simultaneous and sequential treatment of multilevel aortic disease.

    Science.gov (United States)

    Piffaretti, Gabriele; Bonardelli, Stefano; Bellosta, Raffaello; Mariscalco, Giovanni; Lomazzi, Chiara; Tolenaar, Jip L; Zanotti, Camilla; Guadrini, Cristina; Sarcina, Antonio; Castelli, Patrizio; Trimarchi, Santi

    2014-10-01

    The aim of the present study is to report a risk analysis for spinal cord injury in a recent cohort of patients with simultaneous and sequential treatment of multilevel aortic disease. We performed a multicenter study with a retrospective data analysis. Simultaneous treatment refers to descending thoracic and infrarenal aortic lesions treated during the same operation, and sequential treatment refers to separate operations. All descending replacements were managed with endovascular repair. Of 4320 patients, multilevel aortic disease was detected in 77 (1.8%). Simultaneous repair was performed in 32 patients (41.5%), and a sequential repair was performed in 45 patients (58.4%). Postoperative spinal cord injury developed in 6 patients (7.8%). At multivariable analysis, the distance of the distal aortic neck from the celiac trunk was the only independent predictor of postoperative spinal cord injury (odds ratio, 0.75; 95% confidence interval, 0.56-0.99; P=.046); open surgical repair of the abdominal aortic disease was associated with a higher risk of spinal cord injury but did not reach statistical significance (odds ratio, 0.16; 95% confidence interval, 0.02-1.06; P=.057). Actuarial survival estimates at 1, 2, and 5 years after the procedure were 80%±5%, 68%±6%, and 63%±7%, respectively. Spinal cord injury did not impair survival (P=.885). In our experience, the risk of spinal cord injury is still substantial at 8% in patients with multilevel aortic disease. The distance of the distal landing zone from the celiac trunk is a significant predictor of spinal cord ischemia. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  4. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  5. Renal failure after operation for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Olsen, P S; Schroeder, T; Perko, M

    1990-01-01

    Among 656 patients undergoing surgery for abdominal aortic aneurysm, 81 patients (12%) developed postoperative renal failure. Before operation hypotension and shock occurred in 88% of the patients with ruptured aneurysm, whereas none of the patients operated electively were hypotensive. Dialysis...... was performed in 32 patients, while the remaining 49 patients were managed without dialysis. Within 30 days after the operation 47 patients (58%) had died. There was no difference in mortality between patients in dialysis and patients managed without dialysis. Thirteen patients died during follow-up. In six...... cases the death was caused by renal failure only or in combination with failure of other organs. Analysis of the cumulative survival shows that, if the patients survive the postoperative period, their life expectancy is comparable to that of patients without renal complications....

  6. HAS-1 genetic polymorphism in sporadic abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Alberto Balbarini

    2009-04-01

    Full Text Available The hyaluronan synthase 1 (HAS-1 gene encodes a plasma membrane protein that synthesizes hyaluronan (HA, an extracellular matrix molecule. Accumulating evidence emphasizes the relevance of HA metabolism in an increasing number of processes of clinical interest, including abdominal aortic aneurysm (AAA. The existence of aberrant splicing variants of the HAS-1 gene could partly explain the altered extracellular matrix architecture and influence various biological functions, resulting in progressive arterial wall failure in the development of AAA. In the present study, we assessed the hypothesis that HAS-1 genetic 833A/G polymorphism could be associated with the risk of AAA by performing a case-control association study, involving AAA patients and healthy matched donors.

  7. Matrix metalloproteinase-2 gene variants and abdominal aortic aneurysm.

    Science.gov (United States)

    Smallwood, L; Warrington, N; Allcock, R; van Bockxmeer, F; Palmer, L J; Iacopetta, B; Golledge, J; Norman, P E

    2009-08-01

    To investigate associations between two polymorphisms of the matrix metalloproteinase-2 gene (MMP2) and the incidence and progression of abdominal aortic aneurysm (AAA). Cases and controls were recruited from a trial of screening for AAAs. The association between two variants of MMP2 (-1360C>T, and +649C>T) in men with AAA (n=678) and in controls (n=659) was examined using multivariate analyses. The association with AAA expansion (n=638) was also assessed. In multivariate analyses with adjustments for multiple testing, no association between either SNP and AAA presence or expansion was detected. MMP2 -1360C>T and +649C>T variants are not risk factors for AAA.

  8. Incisional abdominal hernia repair with concomitant abdominoplasty: Maintaining umbilical viability

    OpenAIRE

    Robert Phan; Elan Kaplan; Jemma K. Porrett; Yik-Hong Ho; Warren M. Rozen

    2018-01-01

    Introduction: Abdominoplasty and abdominal hernia repair are often carried out in two-stage procedures, and those describing single-stage surgery require careful dissection to preserve often only partial blood supply to the umbilicus to maintain its viability. This paper aims to describe the surgical method of laparoscopic umbilical hernia repair in association with abdominoplasty. Case presentation: A patient presents with an incisional hernia at a previous periumbilical port site of size 14...

  9. Thoracic and abdominal aortic diameters in a general population: MRI-based reference values and association with age and cardiovascular risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mensel, Birger; Hesselbarth, Lydia; Wenzel, Michael; Kuehn, Jens-Peter; Hegenscheid, Katrin [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Doerr, Marcus [University Medicine Greifswald, Department of Internal Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Voelzke, Henry [University Medicine Greifswald, Institute for Community Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Lieb, Wolfgang [Christian Albrechts University, Institute of Epidemiology, Kiel (Germany); Lorbeer, Roberto [Ludwig-Maximilians-University Hospital, Institute of Clinical Radiology, Munich (Germany)

    2016-04-15

    To generate reference values for thoracic and abdominal aortic diameters determined by magnetic resonance imaging (MRI) and analyse their association with cardiovascular risk factors in the general population. Data from participants (n = 1759) of the Study of Health in Pomerania were used for analysis in this study. MRI measurement of thoracic and abdominal aortic diameters was performed. Parameters for calculation of reference values according to age and sex analysis were provided. Multivariable linear regression models were used for determination of aortic diameter-related risk factors, including smoking, blood pressure (BP), high-density lipoprotein cholesterol (HDL-C). For the ascending aorta (β = -0.049, p < 0.001), the aortic arch (β = -0.061, p < 0.001) and the subphrenic aorta (β = -0.018, p = 0.004), the body surface area (BSA)-adjusted diameters were lower in men. Multivariable-adjusted models revealed significant increases in BSA-adjusted diameters with age for all six aortic segments (p < 0.001). Consistent results for all segments were observed for the positive associations of diastolic BP (β = 0.001; 0.004) and HDL (β = 0.035; 0.087) with BSA-adjusted aortic diameters and for an inverse association of systolic BP (β = -0.001). Some BSA-adjusted median aortic diameters are smaller in men than in women. All diameters increase with age, diastolic blood pressure and HDL-C and decrease as systolic BP increases. (orig.)

  10. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  11. Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

    Science.gov (United States)

    Maeda, Koji; Ohki, Takao; Kanaoka, Yuji

    2018-06-01

    The technologies and innovations applicable to endovascular treatment for complex aortic pathologies have progressed rapidly over the last two decades. Although the initial outcomes of an endovascular aortic repair have been excellent, as long-term data became available, complications including endoleaks, endograft migration, and endograft infection have become apparent and are of concern. Previously, the indication for endovascular therapy was restricted to descending thoracic aortic aneurysms and abdominal aortic aneurysms. However, its indication has expanded along with the improvement of techniques and devices, and currently, it has become possible to treat pararenal aortic aneurysms and Crawford type 4 thoracoabdominal aortic aneurysm (TAAA) using the off-the-shelf devices. Additionally, custom-made devices allow for the treatment of arch or more extensive TAAAs. Endovascular treatment is applied not only to aneurysms but also to acute/chronic dissections. However, long-term outcomes are still unclear. This article provides an overview of available devices and the results of endovascular treatment for various aortic pathologies.

  12. Importance of initial stress for abdominal aortic aneurysm wall motion: Dynamic MRI validated finite element analysis

    NARCIS (Netherlands)

    Merkx, M.A.G.; Veer, van 't M.; Speelman, L.; Breeuwer, M.; Buth, J.; Vosse, van de F.N.

    2009-01-01

    Currently the transverse diameter is the primary decision criterion to assess rupture risk in patients with an abdominal aortic aneurysm (AAA). To obtain a measure for more patient-specific risk assessment, aneurysm wall stress, calculated using finite element analysis (FEA), has been evaluated in

  13. Lack of association between inguinal hernia and abdominal aortic aneurysm in a population-based male cohort

    DEFF Research Database (Denmark)

    Henriksen, N A; Sorensen, L T; Jorgensen, L N

    2013-01-01

    Previous studies have reported a higher prevalence of inguinal hernia in patients with abdominal aortic aneurysm (AAA). The aim of this study was to explore the association between inguinal hernia and AAA in a large population-based cohort of men who had screening for AAA....

  14. Atmospheric Pressure and Abdominal Aortic Aneurysm Rupture : Results from a Time Series Analysis and Case-Crossover Study

    NARCIS (Netherlands)

    Penning De Vries, Bas B.L.; Kolkert, Joé L.P.; Meerwaldt, Robbert; Groenwold, Rolf H.H.

    2017-01-01

    Background: Associations between atmospheric pressure and abdominal aortic aneurysm (AAA) rupture risk have been reported, but empirical evidence is inconclusive and largely derived from studies that did not account for possible nonlinearity, seasonality, and confounding by temperature. Methods:

  15. The Abdominal Aortic Aneurysm Statistically Corrected Operative Risk Evaluation (AAA SCORE) for predicting mortality after open and endovascular interventions.

    Science.gov (United States)

    Ambler, Graeme K; Gohel, Manjit S; Mitchell, David C; Loftus, Ian M; Boyle, Jonathan R

    2015-01-01

    Accurate adjustment of surgical outcome data for risk is vital in an era of surgeon-level reporting. Current risk prediction models for abdominal aortic aneurysm (AAA) repair are suboptimal. We aimed to develop a reliable risk model for in-hospital mortality after intervention for AAA, using rigorous contemporary statistical techniques to handle missing data. Using data collected during a 15-month period in the United Kingdom National Vascular Database, we applied multiple imputation methodology together with stepwise model selection to generate preoperative and perioperative models of in-hospital mortality after AAA repair, using two thirds of the available data. Model performance was then assessed on the remaining third of the data by receiver operating characteristic curve analysis and compared with existing risk prediction models. Model calibration was assessed by Hosmer-Lemeshow analysis. A total of 8088 AAA repair operations were recorded in the National Vascular Database during the study period, of which 5870 (72.6%) were elective procedures. Both preoperative and perioperative models showed excellent discrimination, with areas under the receiver operating characteristic curve of .89 and .92, respectively. This was significantly better than any of the existing models (area under the receiver operating characteristic curve for best comparator model, .84 and .88; P AAA repair. These models were carefully developed with rigorous statistical methodology and significantly outperform existing methods for both elective cases and overall AAA mortality. These models will be invaluable for both preoperative patient counseling and accurate risk adjustment of published outcome data. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Superior Reproducibility of the Leading to Leading Edge and Inner to Inner Edge Methods in the Ultrasound Assessment of Maximum Abdominal Aortic Diameter

    DEFF Research Database (Denmark)

    Borgbjerg, Jens; Bøgsted, Martin; Lindholt, Jes S

    2018-01-01

    Objectives: Controversy exists regarding optimal caliper placement in ultrasound assessment of maximum abdominal aortic diameter. This study aimed primarily to determine reproducibility of caliper placement in relation to the aortic wall with the three principal methods: leading to leading edge...

  17. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  18. Aneurisma de la aorta abdominal: Tratamiento endovascular con una endoprótesis fenestrada Abdominal aortic aneurysm: Endovascular treatment with fenestrated endoprothesis

    Directory of Open Access Journals (Sweden)

    Román Rostagno

    2008-12-01

    Full Text Available El tratamiento endovascular de los aneurismas de aorta abdominal es una alternativa a la cirugía abierta para pacientes de alto riesgo. Consiste en la exclusión del saco aneurismático mediante la interposición de una endoprótesis colocada por vía femoral. El tratamiento endovascular no puede ser utilizado en todos los pacientes. Una limitación frecuente la constituye el nacimiento de una arteria visceral desde el saco aneurismático. Para contrarrestar esta limitación recientemente se han desarrollado endoprótesis fenestradas que presentan orificios que se corresponden con el nacimiento de las arterias involucradas en el aneurisma evitando su oclusión, permitiendo de esta manera el tratamiento endovascular. En esta comunicación se presenta un caso de tratamiento endovascular de un aneurisma de aorta abdominal mediante la colocación de una endoprótesis fenestrada en un paciente cuya arteria renal izquierda nacía directamente del saco aneurismático.Endovascular treatment of the abdominal aortic aneurysm is consider an alternative to open surgery for high risk patients. Its goal is to exclude the aneurysm from the circulation by using an endoprothesis introduced from a femoral approach. Patients must be strictly selected to avoid possible complications. The most frequent limitation is related to anatomic contraindications such as visceral arteries involved in the aneurysm. Fenestrated endograft have been recently developed to allow endovascular treatment when anatomic features contraindicate classic endovascular procedures. Fenestrated endograft have holes that match with the origin of the visceral arteries maintaining its potency. In this paper we report the endovascular treatment of an abdominal aortic aneurysm by using a fenestrated endoprothesis in a patient whose left renal artery is originated from the aneurysm.

  19. Repair of large abdominal wall defects with expanded polytetrafluoroethylene (PTFE).

    Science.gov (United States)

    Bauer, J J; Salky, B A; Gelernt, I M; Kreel, I

    1987-01-01

    Most abdominal wall incisional hernias can be repaired by primary closure. However, where the defect is large or there is tension on the closure, the use of a prosthetic material is indicated. Expanded polytetrafluoroethylene (PTFE) patches were used to repair incisional hernias in 28 patients between November 1983 and December 1986. Twelve of these patients (43%) had a prior failure of a primary repair. Reherniation occurred in three patients (10.7%). Wound infections developed in two patients (7.1%), both of whom had existing intestinal stomas, one with an intercurrent pelvic abscess. The prosthetic patch was removed in the patient with the abscess, but the infection was resolved in the other without sequelae. Septic complications did not occur after any operations performed in uncontaminated fields. None of the patients exhibited any undue discomfort, wound pain, erythema, or induration. Complications related to adhesions, erosion of the patch material into the viscera, bowel obstruction, or fistula formation did not occur. Based on this clinical experience, the authors believe that the PTFE patch appears to represent an advance in synthetic abdominal wall substitutes. Images Fig. 1. Fig. 2(left)., Fig. 3(right). PMID:3689012

  20. Atmospheric pressure variations and abdominal aortic aneurysm rupture.

    LENUS (Irish Health Repository)

    Killeen, S D

    2012-02-03

    BACKGROUND: Ruptured abdominal aortic aneurysm (RAAA) presents with increased frequency in the winter and spring months. Seasonal changes in atmospheric pressure mirrors this pattern. AIM: To establish if there was a seasonal variation in the occurrence of RAAA and to determine if there was any association with atmospheric pressure changes. METHODS: A retrospective cohort-based study was performed. Daily atmospheric pressure readings for the region were obtained. RESULTS: There was a statistically significant monthly variation in RAAA presentation with 107 cases (52.5%) occurring from November to March. The monthly number of RAAA and the mean atmospheric pressure in the previous month were inversely related (r = -0.752, r (2) = 0.566, P = 0.03), and there was significantly greater daily atmospheric pressure variability on days when patients with RAAA were admitted. CONCLUSION: These findings suggest a relationship between atmospheric pressure and RAAA.

  1. Animal Models Used to Explore Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Lysgaard Poulsen, J; Stubbe, J; Lindholt, J S

    2016-01-01

    OBJECTIVE: Experimental animal models have been used to investigate the formation, development, and progression of abdominal aortic aneurysms (AAAs) for decades. New models are constantly being developed to imitate the mechanisms of human AAAs and to identify treatments that are less risky than...... those used today. However, to the authors' knowledge, there is no model identical to the human AAA. The objective of this systematic review was to assess the different types of animal models used to investigate the development, progression, and treatment of AAA and to highlight their advantages...... and limitations. METHODS: A search protocol was used to perform a systematic literature search of PubMed and Embase. A total of 2,830 records were identified. After selection of the relevant articles, 564 papers on animal AAA models were included. RESULTS: The most common models in rodents, including elastase...

  2. Clinical Efficacy of Transthoracic Echocardiography for Screening Abdominal Aortic Aneurysm in Turkish Patients.

    Science.gov (United States)

    Kilic, Salih; Saracoglu, Erhan; Cekici, Yusuf

    2018-03-01

    The objective of this study was to investigate the prevalence of abdominal aortic aneurysm (AAA) in Turkish patients aged ≥ 65 years, and to demonstrate the applicability of echocardiography to AAA screening. Transthoracic echocardiography (TTE) was performed in all consecutive patients aged ≥ 65 years who were referred to cardiology clinics or were referred from other outpatient clinics. The abdominal aorta (AA) of each patient was scanned using the same probe, and the time spent was recorded. Demographic and clinic characteristics of the patients were recorded at the end of the echocardiography. Among 1948 patients (mean age 70.9 ± 6 years; 49.8% male), the AA was visualized in 96.3%. AAA was identified in 3.7% (69/1878) of the patients, of whom AAA was previously known in 20.3% (n = 14). The prevalence of unknown AAA was 2.93%. The average time needed to scan and measure the AA was 1 minute and 3 seconds (±23 seconds). Aortic root diameters were significantly higher in the patients with AAA than in those without AAA (34.7 ± 4.2 vs. 29.8 ± 4.7; p < 0.001). Age (per 1 year increase) [odds ratio (OR), 1.245; p < 0.001], male gender (OR, 5.382; p < 0.001), smoking (OR, 2.118; p = 0.037), and aortic root diameter (per 1 mm increase) (OR, 1.299; p < 0.001) were independent predictors of AAA. This study is important in that it showed a high prevalence of AAA in Turkish patients aged ≥ 65 years, and demonstrated that AAA can be visualized in the majority of patients in as little as 1 minute during TTE.

  3. Fetal Abdominal Wall Repair with a Collagen Biomatrix in an Experimental Sheep Model for Gastroschisis

    NARCIS (Netherlands)

    Roelofs, Luc A. J.; Eggink, Alex J.; Hulsbergen-van de Kaa, Christina A.; van den Berg, Paul P.; van Kuppevelt, Toin H.; van Moerkerk, Herman T. B.; Crevels, A. Jane; Lotgering, Fred K.; Feitz, Wout F. J.; Wijnen, Rene M. H.

    2008-01-01

    We evaluated the regeneration of the abdominal wall using a dual- layer collagen biomatrix, and the protective effect on the bowel of fetal abdominal wall repair in a fetal sheep model for gastroschisis. In 14 fetal lambs, the abdominal wall was opened at 79 days' gestation, creating a

  4. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  5. Contemporary strategies for repair of complex thoracoabdominal aortic aneurysms: real-world experiences and multilayer stents as an alternative

    Directory of Open Access Journals (Sweden)

    Ralf Robert Kolvenbach

    Full Text Available Abstract Thoracoabdominal aortic aneurysms (TAAA present special challenges for repair due to their extent, their distinctive pathology, and the fact that they typically cross the ostia of one or more visceral branch vessels. Historically, the established treatment for TAAA was open surgical repair, with the first procedure reported in 1955. Endovascular repair of TAAA with fenestrated and/ or branched endografts, has been studied since the beginning of the current century as a means of mechanical aneurysm exclusion. More recently, flow modulator stents have been employed with the aim at reducing shear stress on aortic aneurysmal wall. In this review we present technical and main results of these techniques, based on literature review and personal experience.

  6. Superior Reproducibility of the Leading to Leading Edge and Inner to Inner Edge Methods in the Ultrasound Assessment of Maximum Abdominal Aortic Diameter.

    Science.gov (United States)

    Borgbjerg, Jens; Bøgsted, Martin; Lindholt, Jes S; Behr-Rasmussen, Carsten; Hørlyck, Arne; Frøkjær, Jens B

    2018-02-01

    Controversy exists regarding optimal caliper placement in ultrasound assessment of maximum abdominal aortic diameter. This study aimed primarily to determine reproducibility of caliper placement in relation to the aortic wall with the three principal methods: leading to leading edge (LTL), inner to inner edge (ITI), and outer to outer edge (OTO). The secondary aim was to assess the mean difference between the OTO, ITI, and LTL diameters and estimate the impact of using either of these methods on abdominal aortic aneurysm (AAA) prevalence in a screening program. Radiologists (n=18) assessed the maximum antero-posterior abdominal aortic diameter by completing repeated caliper placements with the OTO, LTL, and ITI methods on 50 still abdominal aortic images obtained from an AAA screening program. Inter-observer reproducibility was calculated as the limit of agreement with the mean (LoA), which represents expected deviation of a single observer from the mean of all observers. Intra-observer reproducibility was assessed averaging the LoA for each observer with their repeated measurements. Based on data from an AAA screening trial and the estimated mean differences between the three principal methods, AAA prevalence was estimated using each of the methods. The inter-observer LoA of the OTO, ITI, and LTL was 2.6, 1.9, and 1.9 mm, whereas the intra-observer LoA was 2.0, 1.6, and 1.5 mm, respectively. Mean differences of 5.0 mm were found between OTO and ITI measurements, 2.6 mm between OTO and LTL measurements, and 2.4 mm between LTL and ITI measurements. The prevalence of AAA almost doubled using OTO instead of ITI, while the difference between ITI and LTL was minor (3.3% vs. 4.0% AAA). The study shows superior reproducibility of LTL and ITI compared with the OTO method of caliper placement in ultrasound determination of maximum abdominal aortic diameter, and the choice of caliper placement method significantly affects the prevalence of AAAs in screening programs

  7. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  8. Type A aortic dissection in Marfan syndrome: extent of initial surgery determines long-term outcome.

    Science.gov (United States)

    Rylski, Bartosz; Bavaria, Joseph E; Beyersdorf, Friedhelm; Branchetti, Emanuela; Desai, Nimesh D; Milewski, Rita K; Szeto, Wilson Y; Vallabhajosyula, Prashanth; Siepe, Matthias; Kari, Fabian A

    2014-04-01

    Data on outcomes after Stanford type A aortic dissection in patients with Marfan syndrome are limited. We investigated the primary surgery and long-term results in patients with Marfan syndrome who suffered aortic dissection. Among 1324 consecutive patients with aortic dissection type A, 74 with Marfan syndrome (58% men; median age, 37 years [first and third quartiles, 29 and 48 years]) underwent surgical repair (85% acute dissections; 68% DeBakey I; 55% composite valved graft, 30% supracoronary ascending replacement, 15% valve-sparing aortic root replacement; 12% total arch replacement; 3% in-hospital mortality) at 2 tertiary centers in the United States and Europe over the past 25 years. The rate of aortic reintervention with resternotomy was 24% (18 of 74) and of descending aorta (thoracic+abdominal) intervention was 30% (22 of 74) at a median follow-up of 8.4 years (first and third quartiles, 2.2 and 12.7 years). Freedom from need for aortic root reoperation in patients who underwent primarily a composite valved graft or valve-sparing aortic root replacement procedure was 95±3%, 88±5%, and 79±5% and in patients who underwent supracoronary ascending replacement was 83±9%, 60±13%, 20±16% at 5, 10, and 20 years. Secondary aortic arch surgery was necessary only in patients with initial hemi-arch replacement. Emergency surgery for type A dissection in patients with Marfan syndrome is associated with low in-hospital mortality. Failure to extend the primary surgery to aortic root or arch repair leads to a highly complex clinical course. Aortic root replacement or repair is highly recommended because supracoronary ascending replacement is associated with a high need (>40%) for root reintervention.

  9. From tissue iron retention to low systemic haemoglobin levels, new pathophysiological biomarkers of human abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Martinez-Pinna, Roxanna; Lindholt, Jes Sanddal; Madrigal-Matute, Julio

    2014-01-01

    Iron deposits are observed in tissue of abdominal aortic aneurysm (AAA) patients, although the underlying mechanisms are not completely elucidated. Therefore we explored circulating markers of iron metabolism in AAA patients, and tested if they could serve as biomarkers of AAA. Increased red bloo...

  10. Reporting individual surgeon outcomes does not lead to risk aversion in abdominal aortic aneurysm surgery.

    Science.gov (United States)

    Saratzis, A; Thatcher, A; Bath, M F; Sidloff, D A; Bown, M J; Shakespeare, J; Sayers, R D; Imray, C

    2017-02-01

    INTRODUCTION Reporting surgeons' outcomes has recently been introduced in the UK. This has the potential to result in surgeons becoming risk averse. The aim of this study was to investigate whether reporting outcomes for abdominal aortic aneurysm (AAA) surgery impacts on the number and risk profile (level of fitness) of patients offered elective treatment. METHODS Publically available National Vascular Registry data were used to compare the number of AAAs treated in those centres across the UK that reported outcomes for the periods 2008-2012, 2009-2013 and 2010-2014. Furthermore, the number and characteristics of patients referred for consideration of elective AAA repair at a single tertiary unit were analysed yearly between 2010 and 2014. Clinic, casualty and theatre event codes were searched to obtain all AAAs treated. The results of cardiopulmonary exercise testing (CPET) were assessed. RESULTS For the 85 centres that reported outcomes in all three five-year periods, the median number of AAAs treated per unit increased between the periods 2008-2012 and 2010-2014 from 192 to 214 per year (p=0.006). In the single centre cohort study, the proportion of patients offered elective AAA repair increased from 74% in 2009-2010 to 81% in 2013-2014, with a maximum of 84% in 2012-2013. The age, aneurysm size and CPET results (anaerobic threshold levels) for those eventually offered elective treatment did not differ significantly between 2010 and 2014. CONCLUSIONS The results do not support the assumption that reporting individual surgeon outcomes is associated with a risk averse strategy regarding patient selection in aneurysm surgery at present.

  11. Utilization of the National Inpatient Sample for abdominal aortic aneurysm research.

    Science.gov (United States)

    Dua, Anahita; Ali, Fadwa; Traudt, Elizabeth; Desai, Sapan S

    2017-10-01

    Large administrative databases, including the Medicare database by the Centers for Medicare and Medicaid Services, the National Surgical Quality Improvement Project database sponsored by the American College of Surgeons, and the National Inpatient Sample, have been used by major public health agencies for years. More recently, medical researchers have turned to database research to power studies on diseases that are noted to be relatively scarce. This study aimed to review and discuss the utilization of the National Inpatient Sample for abdominal aortic aneurysm research, inclusive of its advantages, disadvantages, and best practices. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  13. Abdominal aortic aneurysms do not develop more aggressively among patients with a positive family history of the disease

    DEFF Research Database (Denmark)

    Mejnert Jørgensen, Trine; Wemmelund, Holger; Green, Anders

    Title: Abdominal aortic aneurysms no not develop more aggressively among patients with a positive family history of the disease Authors: Trine M. M. Joergensen, Holger Wemmelund, Anders Green, Jes Lindholt, Kim Houlind. Introduction: It is well known, that a family history of abdominal aortic...... aneurysm (AAA) strongly increases the risk of developing AAA, but it is still uncertain whether familial AAA’s develops differently than non-familial AAA’s. Objectives: To investigate whether familial AAA’s develop more aggressively than non-familial AAA’s by looking at growth rate, risk of surgery...... and rupture, as well as the size of the aneurysm at the time of diagnosis and the patient´s age at the time of operation, rupture and diagnosis. Design: Observational retrospective longitudinal study Materials: 318 patients (273 men and 45 women) with AAA diagnosed between 1996-2008 in Jutland, Denmark...

  14. WSES guidelines for emergency repair of complicated abdominal wall hernias

    NARCIS (Netherlands)

    M. Sartelli (Massimo); F. Coccolini (Federico); G.H. van Ramshorst (Gabrielle); G. Campanelli (Giampiero); V. Mandala; L. Ansaloni (Luca); E.E. Moore (Ernest); A. Peitzman (Andrew); G.C. Velmahos (George ); F.A. Moore (Fredrick); A. Leppaniemi (Ari); C.C. Burlew (Clay); W.L. Biffl (Walter); K. Koike (Kaoru); Y. Kluger (Yoram); G.P. Fraga (Gustavo); C.A. Ordonez (Carlos); S. Di Saverio (Salomone); F. Agresta; B. Sakakushev (Boris); I. Gerych (Igor); I. Wani (Imtiaz); M.D. Kelly (Michael ); C.A. Gomes (Carlos); M.P. Faro Jr (Mario); K. Taviloglu (Korhan); Z. Demetrashvili (Zaza); J.G. Lee (Jeong ); N. Vettoretto (Nereo); G. Guercioni (Gianluca); C. Tranà (Cristian); Y. Cui (Yijun); K.Y.Y. Kok (Kenneth); W.M. Ghnnam (Wagih); A.E.S. Abbas (Ashraf El-Sayed); N. Sato (Norio); S. Marwah (Sanjay); M. Rangarajan (Muthukumaran); O. Ben-Ishay (Offir); A.R.K. Adesunkanmi (Abdul Rashid); H.A. Segovia Lohse (Helmut); J. Kenig (Jakub); V. Mandalà (Vincenzo); A. Patrizi (Andrea); R. Scibé (Rodolfo); F. Catena (Fausto)

    2013-01-01

    textabstractEmergency repair of complicated abdominal hernias is associated with poor prognosis and a high rate of post-operative complications. A World Society of Emergency Surgery (WSES) Consensus Conference was held in Bergamo in July 2013, during the 2nd Congress of the World Society of

  15. Evaluation by MRA of aortic dilation late after repair of tetralogy of Fallot.

    Science.gov (United States)

    Kay, W Aaron; Cook, Stephen C; Daniels, Curt J

    2013-09-10

    This study evaluated predictors for aortic dilation (AD) in patients with repaired tetralogy of Fallot (rTOF) using magnetic resonance angiography (MRA). AD is common in patients with rTOF and may result in increased morbidity and mortality. There are no guidelines for evaluation of AD for rTOF patients. All adults with rTOF who previously underwent MRA had retrospective aortic measurements at the sinuses of Valsalva (SoV) and ascending aorta (AsAo). Rate of change in diameter was determined in patients with multiple MRAs. Chart review identified risk factors for AD. Univariate and multivariate analyses tested predictors of AD. Of the 87 patients who met the inclusion criteria, 12 (14%) had AD. At baseline, mean diameter was 3.6 ± 0.6 cm and 3.1 ± 0.6 cm at the SoV and AsAo, respectively. The AsAo was larger than the SoV in 17%. Predictors of AD included male gender, age, right aortic arch, pregnancy, older age at complete repair, smoking, and systemic hypertension. Serial studies were available in 55 patients; the rate of growth was slow: 0.4 ± 0.9 mm/year (SoV) and 0.1 ± 0.8mm/year (AsAo). AD is common in rTOF at the SoV and AsAo. Transthoracic echocardiography, which does not always image the AsAo as well as MRA, may not image AD in rTOF in cases in which the AsAo is dilated. Although several risk factors correlate with AD in rTOF, the rate of aortic growth is slow, suggesting that rTOF patients may not require frequent aortic imaging. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Aneurysm-Specific miR-221 and miR-146a Participates in Human Thoracic and Abdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Premakumari Venkatesh

    2017-04-01

    Full Text Available Altered microRNA expression is implicated in cardiovascular diseases. Our objective was to determine microRNA signatures in thoracic aortic aneurysms (TAAs and abdominal aortic aneurysms (AAAs compared with control non-aneurysmal aortic specimens. We evaluated the expression of fifteen selected microRNA in human TAA and AAA operative specimens compared to controls. We observed significant upregulation of miR-221 and downregulation of miR-1 and -133 in TAA specimens. In contrast, upregulation of miR-146a and downregulation of miR-145 and -331-3p were found only for AAA specimens. Upregulation of miR-126 and -486-5p and downregulation of miR-30c-2*, -155, and -204 were observed in specimens of TAAs and AAAs. The data reveal microRNA expression signatures unique to aneurysm location and common to both thoracic and abdominal pathologies. Thus, changes in miR-1, -29a, -133a, and -221 are involved in TAAs and miR-145, -146, and -331-3p impact AAAs. This work validates prior studies on microRNA expression in aneurysmal diseases.

  17. Investigation of relation between visceral and subcutaneous abdominal fat volumes and calcified aortic plaques via multislice computed tomography.

    Science.gov (United States)

    Efe, Duran; Aygün, Fatih; Acar, Türker; Yildiz, Melda; Gemici, Kazım

    2015-08-01

    The present study investigated effect of subcutaneous fat volume and abdominal visceral fat volume on aortic atherosclerosis via multislice computed tomography. The present study comprised 424 subjects who underwent non-contrast-enhanced abdominal CT in our clinic between June 2012 and June 2013. Using dedicated software visceral fat volume was calculated for each individual and then subcutaneous fat volume was calculated by subtracting visceral fat volume from total fat volume. By dividing visceral fat volume/subcutaneous fat volume participants were assigned to three groups according to their mean visceral fat volume/subcutaneous fat volume: Group 1 consisted of subjects with visceral fat volume/subcutaneous fat volume lower than 0.48 (Group 1 fat volume/subcutaneous fat volume equal to or higher than 0.48 and lower than 0.69 (0.48 ≤ Group 2 fat volume/subcutaneous fat volume equal to or higher than 0.69 (Group 3 ≥ 0.69). The mean abdominal aortic calcium scores according to Agatston scoring (au) were 136.8 ± 418.7 au in Group 1, 179.9 ± 463 au in Group 2 and 212.2 ± 486.9 in Group 3, respectively. We have demonstrated a significant correlation between visceral fat volume and abdominal aorta atherosclerosis, while there was absence of significant correlation between subcutaneous fat volume and abdominal atherosclerosis. © The Author(s) 2014.

  18. Intravascular application of electrocautery in a rabbit model of abdominal aortic endarterectomy.

    Science.gov (United States)

    Wang, Chuan; Xin, Yi; Li, Na; Li, Diankun; Li, Jingxing; Gu, Chengxiong

    2017-07-01

    Effective therapies for preventing perioperative complications such as thrombosis and inflammation after coronary endarterectomy (CE) are lacking. Electrocoagulation electrotomes have been routinely used in surgery for their cutting, clotting, and hemostatic properties. As strong flattening tools, their electrocautery function may prevent mechanical intimal-adventitial injury to arterial circulation and attenuate stenosis. The present study investigated the effects of intravascular application of electrocautery on ameliorating inflammation and thrombosis in a rabbit model of abdominal aortic endarterectomy. New Zealand rabbits were randomly divided into the sham, control (endarterectomy), and study (endarterectomy + electrocautery) groups with 10 in each group. Abdominal aortas were partially blocked and intima was removed. Electrocautery was performed with an electrocoagulation electrotome through the entire blocked vessel lumen. Vascular ultrasound parameters, molecular biological and histological characteristics of the abdominal aorta including vascular diameter, blood flow velocity, serum interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) levels, and apoptosis rate of vascular endothelial cells (ECs) were evaluated postoperatively by vascular Doppler ultrasound, ELISA, real-time RT-PCR, flow cytometry, and immunofluorescence at various time points. Compared with the endarterectomy + electrocautery group, the isolated endarterectomy group had significantly increased levels and gene expression of TNF-α and IL-6 (Pelectrocautery has favorable short-term effects on the abdominal aorta and can reduce inflammation in a rabbit model of abdominal aorta endarterectomy. Long-term anti-inflammatory and anti-thrombotic effects on arterial remodeling and the clinical value of electrocautery in CE remain to be determined.

  19. Randomized Clinical Trial on the postoperative use of an abdominal binder after laparoscopic umbilical and epigastric hernia repair

    DEFF Research Database (Denmark)

    Christoffersen, Mette; Olsen, B H; Rosenberg, J

    2015-01-01

    PURPOSE: Application of an abdominal binder is often part of a standard postoperative regimen after ventral hernia repair to reduce pain and seroma formation. However, there is lack of evidence of the clinical effects. The aim of the present study was to investigate the pain- and seroma......-reducing effect of an abdominal binder in patients undergoing laparoscopic umbilical or epigastric hernia repair. METHODS: Based on power analysis, a minimum of 54 patients undergoing laparoscopic umbilical and epigastric hernia repair were to be included. Patients were randomized to abdominal binders vs....... no abdominal binders during the first postoperative week. Standardized surgical technique, anaesthesia, and analgesic regimens were used and study observers were blinded towards the intervention. Postoperative pain (visual analogue score) on day 1 was the primary outcome. In addition, ultrasonographic...

  20. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay J; Johnston, Douglas R; Eagleton, Matthew J; Desai, Milind Y; Svensson, Lars G

    2018-04-01

    Endovascular stent-grafting provides an alternative treatment option for high-risk patients with ascending aortic disease. The feasibility of this approach has been demonstrated before. We assess the updated experience with ascending thoracic endovascular aortic repair and propose a modification of the landing zone classification based on the outcomes. From 2006 to 2016, 39 patients deemed very high risk for open replacement underwent endovascular repair of ascending aorta for acute type A dissection (12, 31%), intramural hematoma (2, 5%), pseudoaneurysm (22, 56%), and chronic dissection suture line entry tear (3, 8%). Ascending thoracic endovascular aortic repair was performed in 36 patients. In 3 patients with pseudoaneurysm, occluder devices were used. Computed tomography imaging analysis was performed, and the extent of aortic pathology was designated by segmental proximity to the left ventricle. Segmental anatomy of the proximal aorta was designed as zone 0A from the annulus to the distal margin of highest coronary, 0B extends from above the coronary to the distal margin of right pulmonary artery, and 0C extends from the right pulmonary artery border to the innominate artery. Multivariable time to event Cox regression analysis was performed to predict mortality, and long-term survival was estimated using the Kaplan-Meier method. Operative mortality was 13%; all 5 deaths occurred after emergency ascending thoracic endovascular aortic repair for type A dissection. Other complications included stroke in 4 patients (10%), myocardial infarction in 2 patients (5%), tracheostomy in 2 patients (5%), and dialysis in 2 patients (5%). In patients with acute type A dissection, the ascending pathology extended into zone 0A in 10 (71%) and 0B in 4 (29%). Among those with pseudoaneurysm, the location of the defect was in 0B in 11 (50%), 0C in 10 (45%), and 0A in 1. Among the patients with chronic dissection, the defect was located in 0C in all 3 (100%). After multivariable

  1. Rapid Two-stage Versus One-stage Surgical Repair of Interrupted Aortic Arch with Ventricular Septal Defect in Neonates

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2008-11-01

    Conclusion: The outcome of rapid two-stage repair is comparable to that of one-stage repair. Rapid two-stage repair has the advantages of significantly shorter cardiopulmonary bypass duration and AXC time, and avoids deep hypothermic circulatory arrest. LVOTO remains an unresolved issue, and postoperative aortic arch restenosis can be dilated effectively by percutaneous balloon angioplasty.

  2. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  3. Aortic valve repair for insufficiency in older children offers unpredictable durability that may not be advantageous over a primary Ross operation†.

    Science.gov (United States)

    Wilder, Travis J; Caldarone, Christopher A; Van Arsdell, Glen S; Pham-Hung, Eric; Gritti, Michael; Al Jughiman, Mohammed; Hickey, Edward J

    2016-03-01

    To evaluate the durability of aortic valve (AoV) repair relative to other strategies for children with significant aortic insufficiency (AI). From 2001 to 2012, 90 children with greater than or equal to moderate AI underwent surgery. Resulting procedures were classified according to final operative outcome: AoV repair (repair; n = 46, 51%), Ross procedure (Ross; n = 21, 23%) or replacement with mechanical or tissue prosthesis [aortic valve replacement (AVR); n = 23, 26%]. Repeated measures (n = 1081 echocardiograms) mixed-model analysis and parametric multiphase risk-adjusted hazard analysis were used to evaluate haemodynamic parameters and durability of operations. Mean age at operation was similar for repair and Ross groups, but slightly higher for the AVR group (10.6, 11 and 13.2, respectively; P = 0.04). Baseline annular dimensions were similar among groups. Of 46 repairs, 85% involved pericardial leaflet extensions (commonly with leaflet shaving and/or commisuroplasty). The remaining repairs were commissuroplasties. On multivariable analysis, repair was associated with increased early (∼1-2 years) AI and increased outflow tract peak pressure gradients relative to Ross and AVR procedures. On univariate analysis, repairs tended to have a larger annulus size compared with Ross or AVR; however, this was not significant on multivariable analysis. There were 25 reinterventions (surgical reoperation = 16; transcatheter intervention = 9) for 22 children. Freedom from surgical reoperation was 64, 100 and 51% at 6 years for repairs, Ross and AVR, respectively (P = 0.05); however, three of five reoperations after AVR were for failed bioprosthetic devices. The freedom from reintervention was not significantly influenced by the type of AoV operation (P = 0.43). Durability of aortic valve repair for children is limited by recurrence of AI and/or stenosis, often within the first few years. After repair, reoperation should be anticipated within ∼7 years. © The Author

  4. Value of volume measurements in evaluating abdominal aortic aneurysms growth rate and need for surgical treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kontopodis, Nikolaos, E-mail: kontopodisn@yahoo.gr [Department of Vascular Surgery, University of Crete Medical School, Heraklion (Greece); Metaxa, Eleni, E-mail: emmetaxa@gmail.com [Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Heraklion, Crete (Greece); Papaharilaou, Yannis, E-mail: yannisp@iacm.forth.gr [Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Heraklion, Crete (Greece); Georgakarakos, Efstratios, E-mail: efstratiosgeorg@gmail.com [Vascular Surgery Department, “Demokritus” University of Thrace Medical School, Alexandroupolis (Greece); Tsetis, Dimitris, E-mail: tsetis@med.uoc.gr [Interventional Radiology Unit, Department of Radiology, University of Crete Medical School, Heraklion, Crete (Greece); Ioannou, Christos V., E-mail: ioannou@med.uoc.gr [Department of Vascular Surgery, University of Crete Medical School, Heraklion (Greece)

    2014-07-15

    Purpose: To examine whether indices other than the traditionally used abdominal aortic aneurysm (AAA) maximum diameter, such as AAA volume, intraluminal thrombus (ILT) thickness and ILT volume, may be superior to evaluate aneurismal enlargement. Materials and methods: Thirty-four small AAAs (initially presenting a maximum diameter <5.5 cm which is the threshold for surgical repair) with an initial and a follow-up CT were examined. Median increase and percentile annual change of these variables was calculated. Correlation between growth rates as determined by the new indices under evaluation and those of maximum diameter were assessed. AAAs were divided according to outcome (surveillance vs. elective repair after follow-up which is based on the maximum diameter criterion) and according to growth rate (high vs. low) based on four indices. Contingency between groups of high/low growth rate regarding each of the four indices on one hand and those regarding need for surgical repair on the other was assessed. Results: A strong correlation between growth rates of maximum diameter and those of AAA and ILT volumes could be established. Evaluation of contingency between groups of outcome and those of growth rate revealed significant associations only for AAA and ILT volumes. Subsequently AAAs with a rapid volumetric increase over time had a likelihood ratio of 10 to be operated compared to those with a slower enlargement. Regarding increase of maximum diameter, likelihood ratio between AAAs with rapid and those with slow expansion was only 3. Conclusion: Growth rate of aneurysms regarding 3Dimensional indices of AAA and ILT volumes is significantly associated with the need for surgical intervention while the same does not hold for growth rates determined by 2Dimensional indices of maximum diameter and ILT thickness.

  5. Value of volume measurements in evaluating abdominal aortic aneurysms growth rate and need for surgical treatment

    International Nuclear Information System (INIS)

    Kontopodis, Nikolaos; Metaxa, Eleni; Papaharilaou, Yannis; Georgakarakos, Efstratios; Tsetis, Dimitris; Ioannou, Christos V.

    2014-01-01

    Purpose: To examine whether indices other than the traditionally used abdominal aortic aneurysm (AAA) maximum diameter, such as AAA volume, intraluminal thrombus (ILT) thickness and ILT volume, may be superior to evaluate aneurismal enlargement. Materials and methods: Thirty-four small AAAs (initially presenting a maximum diameter <5.5 cm which is the threshold for surgical repair) with an initial and a follow-up CT were examined. Median increase and percentile annual change of these variables was calculated. Correlation between growth rates as determined by the new indices under evaluation and those of maximum diameter were assessed. AAAs were divided according to outcome (surveillance vs. elective repair after follow-up which is based on the maximum diameter criterion) and according to growth rate (high vs. low) based on four indices. Contingency between groups of high/low growth rate regarding each of the four indices on one hand and those regarding need for surgical repair on the other was assessed. Results: A strong correlation between growth rates of maximum diameter and those of AAA and ILT volumes could be established. Evaluation of contingency between groups of outcome and those of growth rate revealed significant associations only for AAA and ILT volumes. Subsequently AAAs with a rapid volumetric increase over time had a likelihood ratio of 10 to be operated compared to those with a slower enlargement. Regarding increase of maximum diameter, likelihood ratio between AAAs with rapid and those with slow expansion was only 3. Conclusion: Growth rate of aneurysms regarding 3Dimensional indices of AAA and ILT volumes is significantly associated with the need for surgical intervention while the same does not hold for growth rates determined by 2Dimensional indices of maximum diameter and ILT thickness

  6. Preoperative methylprednisolone enhances recovery after endovascular aortic repair

    DEFF Research Database (Denmark)

    de la Motte, Louise; Kehlet, Henrik; Vogt, Katja

    2014-01-01

    OBJECTIVE: To evaluate effects of preoperative high-dose glucocorticoid on the inflammatory response and recovery after endovascular aortic aneurysm repair (EVAR). BACKGROUND: The postimplantation syndrome after EVAR may delay recovery due to the release of proinflammatory mediators....... Glucocorticoids may reduce postoperative inflammatory responses and enhance recovery, but with limited information on EVAR. METHODS: A single-center, randomized, double-blind, placebo-controlled trial of 153 patients undergoing elective EVAR between November 2009 and January 2013. Patients received 30 mg.......001) and fulfillment of discharge criteria was shorter [2 days (IQR = 2-4 days) vs 3 days (IQR = 3-4 days)] (P factor receptor were also reduced (P

  7. MR imaging of the entry, the abdominal communicating orifice, and the retrograde dissection in aortic dissections

    International Nuclear Information System (INIS)

    Yoshida, Y.; Mukohara, N.; Nakamura, K.; Sugimura, K.; Kono, M.

    1986-01-01

    MR imaging (1.5 T) was performed on 41 patients with aortic dissection. Entries were clearly visualized on the MR images as partial defects of the intimal flap in 18 of 21 patients (85.7%). In eight of ten patients, the locations of abdominal communicating orifices corresponded to the lowest signal intensities of the false lumina. Retrograde disections were diagnosed in all six patients from gradual increases in signal intensities of the false lumina toward the heart. MR imaging was very useful in diagnosing entries of the thoracic aorta, abdominal communicating orifices between true and false lumina, and retrograde dissections

  8. Usefulness of abdominal aortic calcification for screening of peripheral vascular disease

    International Nuclear Information System (INIS)

    Park, Chul Hi; Kim, Jeong Ho; Choi, Soo Jin; Kim, Hyung Sik; Jin, Wook; Yang, Dal Mo

    2006-01-01

    We wanted to evaluate the value of abdominal aortic calcification (AAC), as detected on CT, as a predictor of atherosclerotic stenotic disease of the lower extremity arteries. One hundred three patients who had CT angiography performed for the evaluation of peripheral vascular disease were enrolled in this retrospective study. The volume (mm 3 ) of the AAC was measured on CT. Each lower extremity was divided into 8 segments. The extent of stenosis of the lower extremity artery was manifested as the sum of the stenosis scores for 16 segments (total stenosis score: TSS). The significant stenosis scores (SSS-50 and SSS-75) were defined as the sum of scores for the lower extremity artery segments that had significant stenosis of more than 50% and 75%, respectively. AAC was correlated to the TSS, SSS-50 and SSS-75 with using Spearman's correlation coefficient. The diagnostic performance of AAC for stenosis of a lower extremity artery of more than 50% and 75%, respectively, was evaluated by using the receiver operating characteristic (ROC) curve. The Spearman's correlation coefficients were 0.728 (AAC vs. TSS), 0.662 (AAC vs. SSS-50), and 0.602 (AAC vs. SSS-75), respectively. For significant stenosis more than 50% and 75%, the areas under the ROC curve were 0.898 and 0.866, respectively. The cutoff value, sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 1030 mm 3 , 87%, 88%, 89%. 86% and 87% for stenosis more than 50% and 1030 mm 3 , 87%, 80%, 79%, 88% and 84% for stenosis more than 75%, respectively. Abdominal aortic calcification detected on CT may be a useful predictor of atherosclerotic stenotic disease of lower extremity arteries

  9. In vivo characterization of a new abdominal aortic aneurysm mouse model with conventional and molecular magnetic resonance imaging

    NARCIS (Netherlands)

    Klink, Ahmed; Heynens, Joeri; Herranz, Beatriz; Lobatto, Mark E.; Arias, Teresa; Sanders, Honorius M. H. F.; Strijkers, Gustav J.; Merkx, Maarten; Nicolay, Klaas; Fuster, Valentin; Tedgui, Alain; Mallat, Ziad; Mulder, Willem J. M.; Fayad, Zahi A.

    2011-01-01

    The goal of this study was to use noninvasive conventional and molecular magnetic resonance imaging (MRI) to detect and characterize abdominal aortic aneurysms (AAAs) in vivo. Collagen is an essential constituent of aneurysms. Noninvasive MRI of collagen may represent an opportunity to help detect

  10. Automatic determination of the dynamic geometry of abdominal aortic aneurysm from MR with application to wall stress simulations

    NARCIS (Netherlands)

    Putter, de S.; Breeuwer, M.; Kose, U.; Vosse, van de F.N.; Gerritsen, F.A.; Lemke, H.U.

    2005-01-01

    The current surgical intervention criterion for abdominal aortic aneurysm is based on the maximum transverse diameter of the aorta. Recent research advances indicate that a better rupture predictor may be derived from the wall stress, which can be computed with the finite element method. An

  11. Meta-Analysis of Genome-Wide Association Studies for Abdominal Aortic Aneurysm Identifies Four New Disease-Specific Risk Loci

    NARCIS (Netherlands)

    Jones, G.T.; Tromp, G.; Kuivaniemi, H.; Gretarsdottir, S.; Baas, A.F.; Giusti, B.; Strauss, E.; Hof, F.N. van 't; Webb, T.R.; Erdman, R.; Ritchie, M.D.; Elmore, J.R.; Verma, A.; Pendergrass, S.; Kullo, I.J.; Ye, Z.; Peissig, P.L.; Gottesman, O.; Verma, S.S.; Malinowski, J.; Rasmussen-Torvik, L.J.; Borthwick, K.M.; Smelser, D.T.; Crosslin, D.R.; Andrade, M. de; Ryer, E.J.; McCarty, C.A.; Bottinger, E.P.; Pacheco, J.A.; Crawford, D.C.; Carrell, D.S.; Gerhard, G.S.; Franklin, D.P.; Carey, D.J.; Phillips, V.L.; Williams, M.J.; Wei, W.; Blair, R.; Hill, A.A.; Vasudevan, T.M.; Lewis, D.R.; Thomson, I.A.; Krysa, J.; Hill, G.B.; Roake, J.; Merriman, T.R.; Oszkinis, G.; Galora, S.; Saracini, C.; Abbate, R.; Pulli, R.; Pratesi, C.; Saratzis, A.; Verissimo, A.R.; Bumpstead, S.; Badger, S.A.; Clough, R.E.; Cockerill, G.; Hafez, H.; Scott, D.J.; Futers, T.S.; Romaine, S.P.; Bridge, K.; Griffin, K.J.; Bailey, M.A.; Smith, A.; Thompson, M.M.; Bockxmeer, F.M. van; Matthiasson, S.E.; Thorleifsson, G.; Thorsteinsdottir, U.; Blankensteijn, J.D.; Teijink, J.A.; Wijmenga, C.; Graaf, J. de; Kiemeney, L.A.L.M.; Lindholt, J.S.; Hughes, A.; Bradley, D.T.; Stirrups, K.; Golledge, J.; Norman, P.E.; Powell, J.T.; Humphries, S.E.; Hamby, S.E.; Goodall, A.H.; Nelson, C.P.; Sakalihasan, N.; Courtois, A.; Ferrell, R.E.; Eriksson, P.; Folkersen, L.; Franco-Cereceda, A.; Eicher, J.D.; Johnson, A.D.; Betsholtz, C.; Ruusalepp, A.; Franzen, O.; Schadt, E.E.; Bjorkegren, J.L.; et al.,

    2017-01-01

    RATIONALE: Abdominal aortic aneurysm (AAA) is a complex disease with both genetic and environmental risk factors. Together, 6 previously identified risk loci only explain a small proportion of the heritability of AAA. OBJECTIVE: To identify additional AAA risk loci using data from all available

  12. Influence of atmospheric pressure on infrarenal abdominal aortic aneurysm rupture.

    Science.gov (United States)

    Robert, Nicolas; Frank, Michael; Avenin, Laure; Hemery, Francois; Becquemin, Jean Pierre

    2014-04-01

    Meteorologic conditions have a significant impact on the occurrence of cardiovascular events. Previous studies have shown that abdominal aortic aneurysm rupture (AAAR) may be associated with atmospheric pressure, with conflicting results. Therefore, we aimed to further investigate the nature of the correlation between atmospheric pressure variations and AAAR. Hospital admissions related to AAAR between 2005-2009 were assessed in 19 districts of metropolitan France and correlated with geographically and date-matched mean atmospheric pressures. In parallel and from 2005-2009, all fatal AAARs as reported by death certificates were assessed nationwide and correlated to local atmospheric pressures at the time of aortic rupture. Four hundred ninety-four hospital admissions related to AAAR and 6,358 deaths nationwide by AAAR were identified between 2005-2009. Both in-hospital ruptures and aneurysm-related mortality had seasonal variations, with peak/trough incidences in January and June, respectively. Atmospheric pressure peaks occurred during winter. Univariate analysis revealed a significant association (P atmospheric pressure values and AAAR. After multivariate analysis, mean maximum 1-month prerupture atmospheric pressure had a persistent correlation with both in-hospital relative risk (1.05 [95% confidence interval: 1.03-1.06]; P atmospheric pressure. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Aortic root replacement in 372 Marfan patients: evolution of operative repair over 30 years.

    Science.gov (United States)

    Cameron, Duke E; Alejo, Diane E; Patel, Nishant D; Nwakanma, Lois U; Weiss, Eric S; Vricella, Luca A; Dietz, Harry C; Spevak, Philip J; Williams, Jason A; Bethea, Brian T; Fitton, Torin P; Gott, Vincent L

    2009-05-01

    We reviewed the evolution of practice and late results of aortic root replacement (ARR) in Marfan syndrome patients at our institution. A retrospective clinical review of Marfan patients undergoing ARR at our institution was performed. Follow-up data were obtained from hospital and office records and from telephone contact with patients or their physicians. Between September 1976 and September 2006, 372 Marfan syndrome patients underwent ARR: 269 had a Bentall composite graft, 85 had valve-sparing ARR, 16 had ARR with homografts, and 2 had ARR with porcine xenografts. In the first 24 years of the study, 85% received a Bentall graft; during the last 8 years, 61% had a valve-sparing procedure. There was no operative or hospital mortality among the 327 patients who underwent elective repair; there were 2 deaths among the 45 patients (4.4%) who underwent emergent or urgent operative repair. There were 74 late deaths (70 Bentalls, 2 homograft, and 2 valve-sparing ARRs). The most frequent causes of late death were dissection or rupture of the residual aorta (10 of 74) and arrhythmia (9 of 74). Of the 85 patients who had a valve-sparing procedure, 40 had a David II remodeling operation; there was 1 late death in this group, and 5 patients required late aortic valve replacement for aortic insufficiency. A David I reimplantation procedure using the De Paulis Valsalva graft has been used exclusively since May 2002. All 44 patients in this last group have 0 to 1+ aortic insufficiency. Prophylactic surgical replacement of the ascending aorta in patients with Marfan syndrome has low operative risk and can prevent aortic catastrophe in most patients. Valve-sparing procedures, particularly using the reimplantation technique with the Valsalva graft, show promise but have not yet proven as durable as the Bentall.

  14. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    Science.gov (United States)

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  15. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis

    Directory of Open Access Journals (Sweden)

    María Mercedes López

    2016-02-01

    Full Text Available BACKGROUND AND OBJECTIVES: Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area 30 mm Hg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. CASE REPORT: Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2 mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. CONCLUSION: Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients.

  16. Aortic anatomic severity grade correlates with resource utilization.

    Science.gov (United States)

    Rasheed, Khurram; Cullen, John P; Seaman, Matthew J; Messing, Susan; Ellis, Jennifer L; Glocker, Roan J; Doyle, Adam J; Stoner, Michael C

    2016-03-01

    Potential cost effectiveness of endovascular aneurysm repair (EVAR) compared with open aortic repair (OAR) is offset by the use of intraoperative adjuncts (components) or late reinterventions. Anatomic severity grade (ASG) can be used preoperatively to assess abdominal aortic aneurysms, and provide a quantitative measure of anatomic complexity. The hypothesis of this study is that ASG is directly related to the use of intraoperative adjuncts and cost of aortic repair. Patients who undergo elective OAR and EVAR for abdominal aortic aneurysms were identified over a consecutive 3-year period. ASG scores were calculated manually using three-dimensional reconstruction software by two blinded reviewers. Statistical analysis of cost data was performed using a log transformation. Regression analyses, with a continuous or dichotomous outcome, used a generalized estimating equations approach with the sandwich estimator, being robust with respect to deviations from model assumptions. One hundred forty patients were identified for analysis, n = 33 OAR and n = 107 EVAR. The mean total cost (± standard deviation) for OAR was per thousand (k) $38.3 ± 49.3, length of stay (LOS) 13.5 ± 14.2 days, ASG score 18.13 ± 3.78; for EVAR, mean total cost was k $24.7 ± 13.0 (P = .016), LOS 3.0 ± 4.4 days (P = .012), ASG score 15.9 ± 4.13 (P = .010). In patients who underwent EVAR, 25.2% required intraoperative adjuncts, and analysis of this group revealed a mean total cost of k $31.5 ± 15.9, ASG score 18.48 ± 3.72, and LOS 3.9 ± 4.5, which were significantly greater compared with cases without adjunctive procedures. An ASG score of ≥15 correlated with an increased propensity for requirement of intraoperative adjuncts; odds ratio, 5.75 (95% confidence interval, 1.82-18.19). ASG >15 was also associated with chronic kidney disease, end stage renal disease, hypertension, female sex, increased cost, and use of adjunctive procedures. Complex aneurysm anatomy correlates with increased

  17. On the effect of computed tomography resolution to distinguish between abdominal aortic aneurysm wall tissue and calcification: A proof of concept.

    Science.gov (United States)

    Barrett, H E; Cunnane, E M; O Brien, J M; Moloney, M A; Kavanagh, E G; Walsh, M T

    2017-10-01

    The purpose of this study is to determine the optimal target CT spatial resolution for accurately imaging abdominal aortic aneurysm (AAA) wall characteristics, distinguishing between tissue and calcification components, for an accurate assessment of rupture risk. Ruptured and non-ruptured AAA-wall samples were acquired from eight patients undergoing open surgical aneurysm repair upon institutional review board approval and informed consent was obtained from all patients. Physical measurements of AAA-wall cross-section were made using scanning electron microscopy. Samples were scanned using high resolution micro-CT scanning. A resolution range of 15.5-155μm was used to quantify the influence of decreasing resolution on wall area measurements, in terms of tissue and calcification. A statistical comparison between the reference resolution (15.5μm) and multi-detector CT resolution (744μm) was also made. Electron microscopy examination of ruptured AAAs revealed extremely thin outer tissue structure leverage an improved assessment of AAA rupture risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease.

    Science.gov (United States)

    Kang, W C; Ko, Y-G; Oh, P C; Shin, E K; Park, C-H; Choi, D; Youn, Y N; Lee, D Y

    2016-08-01

    Total arch transposition (TAT) during hybrid endovascular repair for aortic arch disease is believed to allow a better landing zone, but also to be associated with higher peri-operative mortality than partial arch transposition (PAT). Information on this issue is limited. This study was a retrospective analysis. All 53 consecutive patients with aortic arch disease (41 males, mean age 65.0 years) who underwent hybrid endovascular repair with TAT (zone 0, n=20) or PAT (zone 1 or 2, n=33) from 2008 to 2014 were analyzed retrospectively. The peri-operative and late outcomes of these two groups were compared. Baseline characteristics, including EuroSCORE II results, were similar in the two groups. After procedures, peri-operative mortalities and stroke rates were similar in the two groups (5.0% vs. 9.1%, p=1.000, and 10.0% vs. 6.1%, p=.627). Interestingly, all four strokes occurred in patients with a type III aortic arch irrespective of transposition type. Primary success rates (80.0% vs. 69.7%, p=.527) and type I endoleak incidences (20.0% vs. 27.3%, p=.744) were not significantly different. During follow up (mean duration 36.9 months), overall survival (89.7% vs. 87.4% at 1 year and 89.7% vs. 79.3% at 3 years; p=.375) and re-intervention free survival rates (78.6% vs. 92.0% at 1 year; 72.0% vs. 62.2% at 3 years, p=.872) were similar in the two groups. Morbidity and mortality were high within the first year of hybrid endovascular therapy for aortic arch disease, implying that candidates for hybrid procedures need to be selected carefully. Hybrid endovascular repair with TAT was found to have peri-operative mortality, stroke, and long-term survival rates comparable with PAT, so hybrid endovascular repair may be considered, irrespective of type of arch reconstruction, when clinically indicated. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Overexpression of Catalase in Vascular Smooth Muscle Cells Prevents the Formation of Abdominal Aortic Aneurysms

    Science.gov (United States)

    Parastatidis, Ioannis; Weiss, Daiana; Joseph, Giji; Taylor, W Robert

    2013-01-01

    Objective Elevated levels of oxidative stress have been reported in abdominal aortic aneurysms (AAA), but which reactive oxygen species (ROS) promotes the development of AAA remains unclear. Here we investigate the effect of the hydrogen peroxide (H2O2) degrading enzyme catalase on the formation of AAA. Approach and Results AAA were induced with the application of calcium chloride (CaCl2) on mouse infrarenal aortas. The administration of PEG-catalase, but not saline, attenuated the loss of tunica media and protected against AAA formation (0.91±0.1 mm vs. 0.76±0.09 mm). Similarly, in a transgenic mouse model, catalase over-expression in the vascular smooth muscle cells (VSMC) preserved the thickness of tunica media and inhibited aortic dilatation by 50% (0.85±0.14 mm vs. 0.57±0.08 mm). Further studies showed that injury with CaCl2 decreased catalase expression and activity in the aortic wall. Pharmacologic administration or genetic over-expression of catalase restored catalase activity and subsequently decreased matrix metalloproteinase activity. In addition, a profound reduction in inflammatory markers and VSMC apoptosis was evident in aortas of catalase over-expressing mice. Interestingly, as opposed to infusion of PEG-catalase, chronic over-expression of catalase in VSMC did not alter the total aortic H2O2 levels. Conclusions The data suggest that a reduction in aortic wall catalase activity can predispose to AAA formation. Restoration of catalase activity in the vascular wall enhances aortic VSMC survival and prevents AAA formation primarily through modulation of matrix metalloproteinase activity. PMID:23950141

  20. MRI evaluation of the aortic disease

    International Nuclear Information System (INIS)

    Kapuscinski, O.; Polkowski, J.; Zaleska, T.; Walecki, J.; Biesiadko, M.

    1994-01-01

    The goal of our study was to establish the value of MRI in diagnosing aortic disease. During 3 years period 46 patients were examined (12 women aged from 6 to 62 years and 34 men aged from 8 to 72 years). In 28 cases the thoracic aorta was examined, in 6 cases the abdominal aorta and in 12 - both the thoracic and the abdominal aorta. MR images were performed on MRT 50 A Toshiba unit 0.5 T. MR images demonstrated aortic aneurysm (caused by atherosclerosis or trauma), aortic dissections, aortic anomalies (i.e. in Turner syndrome) and non-specific aortitis and vasculitis. We regard MRI as preferable noninvasive imaging technique in diagnosing aortic disease. (author)

  1. 2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias.

    LENUS (Irish Health Repository)

    Birindelli, Arianna

    2017-01-01

    Emergency repair of complicated abdominal wall hernias may be associated with worsen outcome and a significant rate of postoperative complications. There is no consensus on management of complicated abdominal hernias. The main matter of debate is about the use of mesh in case of intestinal resection and the type of mesh to be used. Wound infection is the most common complication encountered and represents an immense burden especially in the presence of a mesh. The recurrence rate is an important topic that influences the final outcome. A World Society of Emergency Surgery (WSES) Consensus Conference was held in Bergamo in July 2013 with the aim to define recommendations for emergency repair of abdominal wall hernias in adults. This document represents the executive summary of the consensus conference approved by a WSES expert panel. In 2016, the guidelines have been revised and updated according to the most recent available literature.

  2. Hybrid endovascular treatment of an aortic root and thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome.

    Science.gov (United States)

    Gelpi, Guido; Mazzaccaro, Daniela; Romagnoni, Claudia; Contino, Monica; Antona, Carlo

    2013-05-01

    This report describes the hybrid endovascular treatment of an aortic root dilatation and a thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome. A 50-year-old male, in hemodialysis for polycystic kidney and polycystic liver, was referred to our department for aortic root dilatation of 5 cm and a 6.3-cm thoracoabdominal aneurysm . He already underwent surgical repair of abdominal aortic aneurysm 10 years ago, complicated by pseudoaneurysm of the proximal anastomosis that had been treated in another center, with an endoprosthesis. The patient underwent aortic root replacement, aortic valve sparing operation, and rerouting of the superior mesenteric artery and celiac trunk to the ascending aorta. The thoracoabdominal aneurysm was excluded with an endoprosthesis few days after the surgical step. The 12-month computed tomography scan confirmed the complete exclusion of the thoracoabdominal aneurysm.

  3. Free-breathing black-blood CINE fast-spin echo imaging for measuring abdominal aortic wall distensibility: a feasibility study

    Science.gov (United States)

    Lin, Jyh-Miin; Patterson, Andrew J.; Chao, Tzu-Cheng; Zhu, Chengcheng; Chang, Hing-Chiu; Mendes, Jason; Chung, Hsiao-Wen; Gillard, Jonathan H.; Graves, Martin J.

    2017-05-01

    The paper reports a free-breathing black-blood CINE fast-spin echo (FSE) technique for measuring abdominal aortic wall motion. The free-breathing CINE FSE includes the following MR techniques: (1) variable-density sampling with fast iterative reconstruction; (2) inner-volume imaging; and (3) a blood-suppression preparation pulse. The proposed technique was evaluated in eight healthy subjects. The inner-volume imaging significantly reduced the intraluminal artifacts of respiratory motion (p  =  0.015). The quantitative measurements were a diameter of 16.3  ±  2.8 mm and wall distensibility of 2.0  ±  0.4 mm (12.5  ±  3.4%) and 0.7  ±  0.3 mm (4.1  ±  1.0%) for the anterior and posterior walls, respectively. The cyclic cross-sectional distensibility was 35  ±  15% greater in the systolic phase than in the diastolic phase. In conclusion, we developed a feasible CINE FSE method to measure the motion of the abdominal aortic wall, which will enable clinical scientists to study the elasticity of the abdominal aorta.

  4. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. Editor's Choice - High Annual Hospital Volume is Associated with Decreased in Hospital Mortality and Complication Rates Following Treatment of Abdominal Aortic Aneurysms: Secondary Data Analysis of the Nationwide German DRG Statistics from 2005 to 2013.

    Science.gov (United States)

    Trenner, Matthias; Kuehnl, Andreas; Salvermoser, Michael; Reutersberg, Benedikt; Geisbuesch, Sarah; Schmid, Volker; Eckstein, Hans-Henning

    2018-02-01

    The aim of this study was to analyse the association between annual hospital procedural volume and post-operative outcomes following repair of abdominal aortic aneurysms (AAA) in Germany. Data were extracted from nationwide Diagnosis Related Group (DRG) statistics provided by the German Federal Statistical Office. Cases with a diagnosis of AAA (ICD-10 GM I71.3, I71.4) and procedure codes for endovascular aortic repair (EVAR; OPS 5-38a.1*) or open aortic repair (OAR; OPS 5-38.45, 5-38.47) treated between 2005 and 2013 were included. Hospitals were empirically grouped to quartiles depending on the overall annual volume of AAA procedures. A multilevel multivariable regression model was applied to adjust for sex, medical risk, type of procedure, and type of admission. Primary outcome was in hospital mortality. Secondary outcomes were complications, use of blood products, and length of stay (LOS). The association between AAA volume and in hospital mortality was also estimated as a function of continuous volume. A total of 96,426 cases, of which 11,795 (12.6%) presented as ruptured (r)AAA, were treated in >700 hospitals (annual median: 501). The crude in hospital mortality was 3.3% after intact (i)AAA repair (OAR 5.3%; EVAR 1.7%). Volume was inversely associated with mortality after OAR and EVAR. Complication rates, LOS, and use of blood products were lower in high volume hospitals. After rAAA repair, crude mortality was 40.4% (OAR 43.2%; EVAR 27.4%). An inverse association between mortality and volume was shown for rAAA repair; the same accounts for the use of blood products. When considering volume as a continuous variate, an annual caseload of 75-100 elective cases was associated with the lowest mortality risk. In hospital mortality and complication rates following AAA repair are inversely associated with annual hospital volume. The use of blood products and the LOS are lower in high volume hospitals. A minimum annual case threshold for AAA procedures might improve

  6. Extending Abdominal Aortic Aneurysm Detection to Older Age Groups

    DEFF Research Database (Denmark)

    Makrygiannis, Georgios; Labalue, Philippe; Erpicum, Marie

    2016-01-01

    . Current screening policies (e.g., men aged 65-74 years), however, do not account for aging and increased life expectancy of Western populations. This study investigated AAA detection by extending the target population to older age groups (75-85 years). METHODS: AAA screening was conducted in the County......-74 age group but rose to 7.3% in the age-extended group (75-85 years). Further in addition to age, height, current smoking, history of coronary artery disease, hypercholesterolemia, peripheral artery disease of the lower limbs, and varicose veins were significantly associated with the presence of AAA......BACKGROUND: There is evident benefit in terms of reduced aneurysm-related mortality from screening programs of abdominal aortic aneurysm (AAA) in men aged 65 years and more. Recent studies in the United Kingdom and Sweden have shown a decline of the prevalence of AAA in the general population...

  7. Spontaneous Retroperitoneal Hematoma Simulating Ruptured Infrarenal Aortic Aneurysm in a Patient with End-Stage Renal Disease

    Science.gov (United States)

    Li, JYY; Chan, YC; Qing, KX; Cheng, SW

    2014-01-01

    We reported a case of spontaneous retroperitoneal hematoma (SRH) simulating a ruptured infrarenal aortic aneurysm. A 72-year-old man with a history of infrarenal aortic aneurysm and end-stage renal disease on hemodialysis presented with malaise and nonspecific central abdominal pain and left loin discomfort. An emergency computed tomography scan showed a large retroperitoneal hematoma and clinical suspicion of ruptured infrarenal aortic aneurysm. However, the hematoma was discontinuous with the aneurysm sac and raised the clinical suspicion on dual pathology. The SRH was treated conservatively with transfusion of blood products, and the aneurysm was treated with nonemergency endovascular repair electively. This case demonstrates the importance of recognizing different clinical and radiological characteristics and be aware of dual pathology. PMID:28031651

  8. Cesarean section after abdominal mesh repair for pregnancy-related desmoid tumor: a case report

    Directory of Open Access Journals (Sweden)

    Ooi S

    2017-07-01

    Full Text Available Sara Ooi, Harry Ngo Obstetrics and Gynaecology Department, Liverpool Hospital, Liverpool, NSW, Australia Abstract: We report the case of a 32-year-old gravida 2 para 1 woman with a background of partially resected desmoid tumor (DT arising from the previous cesarean section (CS scar. This case details the management of her DT by surgical resection and mesh repair and second pregnancy following this. Pregnancy-related DTs are a relatively rare entity, and there is a paucity of literature regarding their management during pregnancy. There are only five reported cases of DTs arising from CS scars. To our knowledge, this is the only report to illustrate that subsequent CS is possible after desmoid resection and abdominal mesh repair. It provides evidence that CS can be safely accomplished following abdominal wall reconstructions and further arguments against elective lower segment CS. Keywords: abdominal wall, cesarean section, complications, desmoid tumor, surgical mesh

  9. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    Science.gov (United States)

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Polymorphisms of the MMP-9 gene and abdominal aortic aneurysm

    Science.gov (United States)

    Smallwood, Linda; Allcock, Richard; van Bockxmeer, Frank; Warrington, Nicole; Palmer, Lyle J; Iacopetta, Barry; Golledge, Jonathan; Norman, Paul E

    2008-01-01

    Background Increased matrix metalloproteinase-9 (MMP-9) activity has been implicated in the formation of abdominal aortic aneurysms (AAAs). The aim of the present study was to explore the association between potentially functional variants of the MMP-9 gene and AAA. Method The −1562C>T and −1811A>T variants of the MMP-9 gene were genotyped in 678 men with AAAs (>30mm in diameter) and 659 controls (aortic diameter 19−22mm) recruited from a population-based trial of screening for AAAs. The levels of MMP-9 were measured in a random subset of 300 cases and 84 controls. The association between genetic variants (including haplotypes) and AAA was assessed using multivariate logistic regression. Results There was no association between the MMP-9 −1562C>T (OR 0.70 95%CI 0.27, 1.82) or −1811A>T (OR 0.71, 95%CI 0.28, 1.85) genotypes, or the most common haplotype (OR 0.81 95%CI 0.62, 1.05), and AAA. The serum MMP-9 concentration (ng/mL) was higher in cases than controls and in minor allele carriers in cases and controls although the differences were not statistically significant. Conclusion The results suggest that a genetic tendency to have higher levels of circulating MMP-9 is not associated with AAAs. PMID:18763261

  11. Risk factors and early outcomes of acute renal injury after thoracic aortic endograft repair for type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Luo S

    2017-08-01

    Full Text Available Songyuan Luo,* Huanyu Ding,* Jianfang Luo, Wei Li, Bing Ning, Yuan Liu, Wenhui Huang, Ling Xue, Ruixin Fan, Jiyan Chen Cardiology Department, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China *These authors contributed equally to this work Background: Thoracic endovascular aortic repair (TEVAR has become an emerging treatment modality for acute type B aortic dissection (TBAD patients in recent years. The risk factors and impacts of acute kidney injury (AKI after percutaneous TEVAR, however, have not been widely established.Methods: We retrospectively studied the clinical records of 305 consecutive patients who admitted to our institution and had TEVAR for TBAD between December 2009 and June 2013. The patients were routinely monitored for their renal functions preoperatively until 7 days after TEVAR. The Kidney Disease Improving Global Guidelines (KDIGO criteria were used for AKI.Results: Of the total 305 consecutive patients, 84 (27.5% developed AKI after TEVAR, comprising 66 (21.6% patients in KDIGO stage 1, 6 (2.0% patients in stage 2 and 12 (3.9% patients in stage 3. From the logistic regression analysis, systolic blood pressure (SBP on admission >140 mmHg (odds ratio [OR], 2.288; 95% CI, 1.319–3.969 and supra-aortic branches graft bypass hybrid surgery (OR, 3.228; 95% CI, 1.526–6.831 were independent risk factors for AKI after TEVAR. Local anesthesia tended to be a protective factor (OR, 0.563; 95% CI, 0.316–1.001. The preoperative renal function, angiotensin-converting enzyme inhibitor/angiotensin receptor blocker or statin administration, volume of contrast agent, range of TBAD and false lumen involving renal artery were not associated with post-operation AKI. The in-hospital mortality and major adverse events were markedly increased with the occurrence of AKI (7.1% vs 0.9%, P=0

  12. Evaluación del riesgo de ruptura de aneurismas de aorta abdominal personalizados mediante factores biomecánicos/Patient-specific abdominal aortic aneurysms rupture risk assessment by means of biomechanical factors

    Directory of Open Access Journals (Sweden)

    Ariel Zúñiga‐Reyes

    2014-05-01

    Full Text Available El Aneurisma de Aorta Abdominal es la dilatación localizada, irreversible y progresiva que experimenta la pared aortica. Esta patología ha sido reconocida como un importante problema de salud, puesto que su ruptura está asociada mayormente a consecuencias fatales. La falta de criterios fiables, respecto a los actualmente utilizados, para la evaluación del riesgo de ruptura, constituye un inconveniente en la gestión clínica de la enfermedad. El presente trabajo tiene como objetivo evaluar el riesgo de ruptura de Aneurismas de Aorta Abdominal, mediante indicadores numéricos, como es previsto por el enfoque biomecánico. Fueron utilizadas técnicas de modelación por elementos finitos para determinar el comportamiento del flujo sanguíneo y el estado tensional de la pared arterial. Los resultados mostraron que ninguno de los aneurismas analizados presenta riesgo de ruptura elevado y que la evaluación del riesgo de ruptura mediante índices numéricos, es un camino viable para prever la ruptura de un aneurisma específico.Palabras claves: aneurisma de aorta abdominal, factores biomecánicos, interacción fluido-sólido, riesgo de ruptura.______________________________________________________________________________AbstractAbdominal Aortic Aneurysm is a localized, progressive and permanent dilation of the infra-renal aorta.AAA has increasingly been recognized as an important health problem in the last decades. The AAA rupture is mostly associated with fatal consequences. The lack of more reliable criteria for rupture riskassessing, results in a problem in the clinical management of the disease. This paper aims to assess the rupture risk of abdominal aortic aneurysms by means of numerical indexes, as envisaged by the biomechanical approach. Finite Volume Techniques were used to determine the blood flow behavior within aneurysmatic sac and the structural state of the arterial wall. The results showed that none of the assessed aneurysms is at

  13. Mesh versus non-mesh repair of ventral abdominal hernias

    International Nuclear Information System (INIS)

    Jawaid, M.A.; Talpur, A.H.

    2008-01-01

    To investigate the relative effectiveness of mesh and suture repair of ventral abdominal hernias in terms of clinical outcome, quality of life and rate of recurrence in both the techniques. This is a retrospective descriptive analysis of 236 patients with mesh and non-mesh repair of primary ventral hernias performed between January 2000 to December 2004 at Surgery Department, Liaquat University of Medical and Health Sciences, Jamshoro. The record sheets of the patients were analyzed and data retrieved to compare the results of both techniques for short-term and long-term results. The data retrieved is statistically analyzed on SPSS version 11. There were 43 (18.22%) males and 193 (81.77%) females with a mean age of 51.79 years and a range of 59 (81-22). Para-umbilical hernia was the commonest of ventral hernia and accounted for 49.8% (n=118) of the total study population followed by incisional hernia comprising 24% (n=57) of the total number. There was a significant difference in the recurrent rate at 3 years interval with 23/101 (22.77%) recurrences in suture-repaired subjects compared to 10/135 (7.40%) in mesh repair group. Chronic pain lasting up to 1-2 years was noted in 14 patients with suture repair. Wound infection is comparatively more common (8.14%) in mesh group. The other variables such as operative and postoperative complications, total hospital stay and quality of life is also discussed. Mesh repair of ventral hernia is much superior to non-mesh suture repair in terms of recurrence and overall outcome. (author)

  14. Endovascular repair or medical treatment of acute type B aortic dissection? A comparison

    Energy Technology Data Exchange (ETDEWEB)

    Chemelli-Steingruber, I. [Department of Radiology, Innsbruck Medical University (Austria); Chemelli, A. [Department of Radiology, Innsbruck Medical University (Austria)], E-mail: andreas.chemelli@i-med.ac.at; Strasak, A. [Department of Medical Statistics, Informatics and Health Economics, Innsbruck Medical University (Austria); Hugl, B. [Department of Vascular Surgery, Innsbruck Medical University (Austria); Hiemetzberger, R. [Department of Cardiology, Innsbruck Medical University (Austria); Jaschke, W.; Glodny, B.; Czermak, B.V. [Department of Radiology, Innsbruck Medical University (Austria)

    2010-01-15

    Introduction: The aim of this retrospective study was to compare the outcome of thoracic endovascular aortic repair (TEVAR) to that of medical therapy in patients with acute type B aortic dissection (TBD). Materials and methods: From July 1996 to April 2008, 88 patients presenting with acute TBD underwent either TEVAR (group A, n = 38) or medical therapy (group B, n = 50). Indications for TEVAR were intractable pain, aortic branch compromise resulting in end-organ ischemia, rapid aortic dilatation and rupture. Follow-up was performed postinterventionally, at 3, 6 and 12 months and yearly thereafter and included clinical examinations and computed tomography (CT), as well as aortic diameter measurements and assessment of thrombosis. Results: Mean follow-up was 33 months in group A and 36 months in group B. The overall mortality rate was 23.7% in group A and 24% in group B, where 4 patients died of late aortic rupture. In group A, complications included 9 endoleaks and 4 retrograde type A dissections, 3 patients were converted to open surgery and 2 needed secondary intervention. None of the patients developed paraplegia. In group B, 4 patients were converted to open surgery and 2 to TEVAR. The maximal aortic diameter increased in both groups. Regarding the extent of thrombosis, our analyses showed slightly better overall results after TEVAR, but they also showed a tendency towards approximation between the two groups during follow-up. Conclusion: TEVAR is a feasible treatment option in acute TBD. However, several serious complications may occur during and after TEVAR and it should therefore be reserved to patients with life-threatening symptoms.

  15. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. The Weekend Effect in AAA Repair.

    Science.gov (United States)

    O'Donnell, Thomas F X; Li, Chun; Swerdlow, Nicholas J; Liang, Patric; Pothof, Alexander B; Patel, Virendra I; Giles, Kristina A; Malas, Mahmoud B; Schermerhorn, Marc L

    2018-04-18

    Conflicting reports exist regarding whether patients undergoing surgery on the weekend or later in the week experience worse outcomes. We identified patients undergoing abdominal aortic aneurysm (AAA) repair in the Vascular Quality Initiative between 2009 and 2017 [n = 38,498; 30,537 endovascular aneurysm repair (EVAR) and 7961 open repair]. We utilized mixed effects logistic regression to compare adjusted rates of perioperative mortality based on the day of repair. Tuesday was the most common day for elective repair (22%), Friday for symptomatic repairs (20%), and ruptured aneurysms were evenly distributed. Patients with ruptured aneurysms experienced similar adjusted mortality whether they underwent repair during the week or on weekends. Transfers of ruptured AAA were more common over the weekend. However, patients transferred on the weekend experienced higher adjusted mortality than those transferred during the week (28% vs 21%, P = 0.02), despite the fact that during the week, transferred patients actually experienced lower adjusted mortality than patients treated at the index hospital (21% vs 31%, P AAA repair. However, patients with ruptured AAA transferred on the weekend experienced higher mortality than those transferred during the week, suggesting a need for improvement in weekend transfer processes.

  17. Mortality from ruptured abdominal aortic aneurysms: clinical lessons from a comparison of outcomes in England and the USA.

    Science.gov (United States)

    Karthikesalingam, Alan; Holt, Peter J; Vidal-Diez, Alberto; Ozdemir, Baris A; Poloniecki, Jan D; Hinchliffe, Robert J; Thompson, Matthew M

    2014-03-15

    The outcome of patients with ruptured abdominal aortic aneurysm (rAAA) varies by country. Study of practice differences might allow the formulation of pathways to improve care. We compared data from the Hospital Episode Statistics for England and the Nationwide Inpatient Sample for the USA for patients admitted to hospital with rAAA from 2005 to 2010. Primary outcomes were in-hospital mortality, mortality after intervention, and decision to follow non-corrective treatment. In-hospital mortality and the rate of non-corrective treatment were analysed by binary logistic regression for each health-care system, after adjustment for age, sex, year, and Charlson comorbidity index. The study included 11,799 patients with rAAA in England and 23,838 patients with rAAA in the USA. In-hospital mortality was lower in the USA than in England (53·05% [95% CI 51·26-54·85] vs 65·90%; pUSA than in England (19,174 [80·43%] vs 6897 [58·45%]; pUSA than in England (4003 [20·88%] vs 589 [8·54%]; pUSA). These observations persisted in age-matched and sex-matched comparisons. In both countries, reduced mortality was associated with increased use of endovascular repair, increased hospital caseload (volume) for rAAA, high hospital bed capacity, hospitals with teaching status, and admission on a weekday. In-hospital survival from rAAA, intervention rates, and uptake of endovascular repair are lower in England than in the USA. In England and the USA, the lowest mortality for rAAA was seen in teaching hospitals with larger bed capacities and doing a greater proportion of cases with endovascular repair. These common factors suggest strategies for improving outcomes for patients with rAAA. None. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Hemoglobin induces monocyte recruitment and CD163-macrophage polarization in abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Rubio-Navarro, Alfonso; Amaro Villalobos, Juan Manuel; Lindholt, Jes S

    2015-01-01

    BACKGROUND: Increased hemoglobin (Hb) accumulation was reported in abdominal aortic aneurysms (AAAs). CD163 is a macrophage receptor involved in tissue Hb clearance, however its role in AAA has not been reported. We investigated the role of Hb on monocyte recruitment and differentiation towards CD......163 expressing macrophages ex vivo, in vitro and in human AAA. METHODS AND RESULTS: CD163 mRNA and protein expression was significantly higher in human AAA (n=7) vs. healthy wall (n=6). CD163 was predominantly found in adventitia of AAA, coinciding with areas rich in hemosiderin and adjacent...

  19. Endovascular Repair of Traumatic Rupture of the Thoracic Aorta: Single-Center Experience

    International Nuclear Information System (INIS)

    Saratzis, Nikolaos A.; Saratzis, Athanasios N.; Melas, Nikolaos; Ginis, Georgios; Lioupis, Athanasios; Lykopoulos, Dimitrios; Lazaridis, John; Dimitrios, Kiskinis

    2007-01-01

    Purpose. Traumatic rupture of the thoracic aorta secondary to blunt chest trauma is a life-threatening emergency and a common cause of death, usually following violent collisions. The objective of this retrospective report was to evaluate the efficacy of endovascular treatment of thoracic aortic disruptions with a single commercially available stent-graft. Methods. Nine men (mean age 29.5 years) were admitted to our institution between January 2003 and January 2006 due to blunt aortic trauma following violent motor vehicle collisions. Plain chest radiography, spiral computed tomography, aortography, and transesophageal echocardiography were used for diagnostic purposes in all cases. All patients were diagnosed with contained extramural thoracic aortic hematomas, secondary to aortic disruption. One patient was also diagnosed with a traumatic thoracic aortic dissection, secondary to blunt trauma. All subjects were poor surgical candidates, due to major injuries such as multiple bone fractures, abdominal hematomas, and pulmonary contusions. All repairs were performed using the EndoFit (LeMaitre Vascular) stent-graft. Results. Complete exclusion of the traumatic aortic disruption and pseudoaneurysm was achieved and verified at intraoperative arteriography and on CT scans, within 10 days of the repair in all patients. In 1 case the deployment of a second cuff was necessary due to a secondary endoleak. In 2 cases the left subclavian artery was occluded to achieve adequate graft fixation. No procedure-related deaths have occurred and no cardiac or peripheral vascular complications were observed within the 12 months (range 8-16 months) follow-up. Conclusions. This is the first time the EndoFit graft has been utilized in the treatment of thoracic aortic disruptions secondary to chest trauma. The repair of such pathologies is technically feasible and early follow-up results are promising

  20. Cesarean section after abdominal mesh repair for pregnancy-related desmoid tumor: a case report.

    Science.gov (United States)

    Ooi, Sara; Ngo, Harry

    2017-01-01

    We report the case of a 32-year-old gravida 2 para 1 woman with a background of partially resected desmoid tumor (DT) arising from the previous cesarean section (CS) scar. This case details the management of her DT by surgical resection and mesh repair and second pregnancy following this. Pregnancy-related DTs are a relatively rare entity, and there is a paucity of literature regarding their management during pregnancy. There are only five reported cases of DTs arising from CS scars. To our knowledge, this is the only report to illustrate that subsequent CS is possible after desmoid resection and abdominal mesh repair. It provides evidence that CS can be safely accomplished following abdominal wall reconstructions and further arguments against elective lower segment CS.

  1. Increased levels of thioredoxin in patients with abdominal aortic aneurysms (AAAs). A potential link of oxidative stress with AAA evolution

    DEFF Research Database (Denmark)

    Martinez-Pinna, R; Lindholt, Jes S.; Blanco-Colio, L M

    2010-01-01

    Oxidative stress is a main mechanism involved in vascular pathologies. Increased thioredoxin (TRX) levels have been observed in several oxidative stress-associated cardiovascular diseases. We aim to test the potential role of TRX as a biomarker of oxidative stress in abdominal aortic aneurysm (AAA)....

  2. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  3. Percutaneous implantation of thoracic and abdominal aortic prostheses in patients at high surgical risk

    Directory of Open Access Journals (Sweden)

    Juan C Ortiz

    2013-02-01

    Full Text Available Introducción: el aneurisma aórtico es frecuente; su ruptura depende del diámetro. La cirugía es el manejo de elección; como alternativa está el implante intraluminal de stents. Objetivo: analizar el impacto del implante percutáneo de los stents aórticos en pacientes de alto riesgo quirúrgico con seguimiento mínimo de un año. Método: estudio descriptivo llevado a cabo desde diciembre de 2005 hasta marzo de 2010, en el que se incluyeron 125 pacientes con aneurisma de aorta torácica o abdominal, criterio quirúrgico por su diámetro y que además fueron rechazados por cirugía dado su alto riesgo. Los desenlaces fueron: muerte intraoperatoria, por cualquier causa y relacionada con el aneurisma a uno, seis y doce meses. Las complicaciones se definieron como las vasculares ocurridas durante los primeros treinta días. Resultados: el aneurisma abdominal fue más frecuente (70,4%. La mortalidad total a un seguimiento de 25,7 meses fue 14,8%; de este porcentaje 5,2% fallecieron por causas relacionadas con el aneurisma. Un paciente falleció durante la intervención. Se reintervinieron 4,3% por fugas. Hubo mayor mortalidad relacionada con el aneurisma en los torácicos (14,7 vs. 1,2% p=0,003 y tendencia en los de mayor diámetro (6,9 vs. 5,7 cm p=0,210. No hubo relación entre mortalidad y diabetes mellitus, tabaquismo, enfermedad coronaria, hipertensión arterial o dislipidemia. Conclusiones: la mortalidad relacionada con el aneurisma en pacientes intervenidos con stent graft aórtico es baja. Ésta se asoció a la torácica y al mayor diámetro aneurismático. Las complicaciones no significaron un aumento en mortalidad. En conclusión, en pacientes con aneurisma aórtico y alto riesgo quirúrgico rechazados para cirugía abierta, el abordaje percutáneo es un tratamiento seguro y eficaz a un seguimiento a mediano plazo.Introduction: aortic aneurysm is common; its rupture depends on the diameter. Surgery is the treatment of choice, and

  4. Ascending aortic injuries following blunt trauma.

    Science.gov (United States)

    Sun, Xiumei; Hong, Jenny; Lowery, Robert; Goldstein, Steven; Wang, Zuyue; Lindsay, Joseph; Hill, Peter C; Corso, Paul J

    2013-11-01

    The diagnosis and the management of traumatic thoracic aortic injuries have undergone significant changes due to new technology and improved prehospital care. Most of the discussions have focused on descending aortic injuries. In this review, we discuss the recent management of ascending aortic injuries. We found 5 cohort studies on traumatic aortic injuries and 11 case reports describing ascending aortic injuries between 1998 to the present through Medline research. Among case reports, 78.9% of cases were caused by motor vehicle accidents (MVA). 42.1% of patients underwent emergent open repair and the operative mortality was 12.5%. 36.8% underwent delayed repair. Associated injuries occurred in 84.2% of patients. Aortic valve injury was concurrent in 26.3% of patients. The incidence of ascending aortic injury ranged 1.9-20% in cohort studies. Traumatic injuries to the ascending aorta are relatively uncommon among survivors following blunt trauma. Aortography has been replaced by computed tomography and echocardiography as a diagnostic tool. Open repair, either emergent or delayed, remains the treatment of choice. © 2013 Wiley Periodicals, Inc.

  5. Vascular Rupture Caused by a Molding Balloon during Endovascular Aneurysm Repair: Case Report

    International Nuclear Information System (INIS)

    Lee, Hee Young; Do, Young Soo; Park, Hong Suk; Park, Kwang Bo; Kim, Young Wook; Kim, Dong Ik

    2011-01-01

    Endovascular aneurysm repair (EVAR) has been accepted as an alternative to traditional open surgery in selected patients. Despite the minimally invasiveness of this treatment, several complications may occur during or after EVAR. Complications include endoleak, aortic dissection, distal embolism, or iatrogenic injury to the access artery. However, there are few reports on the vascular rupture caused by a molding balloon during EVAR. We report two cases of infrarenal abdominal aortic aneurysms complicated by procedure-related aortic or iliac artery rupture by the molding balloon during EVAR. In our cases, we observed suddenly abrupt increase of the diameter of the endograft during balloon inflation, because we inflated the balloon rapidly. In conclusion, careful attention must be paid during inflation of the molding balloon to prevent vascular rupture.

  6. Methods of abdominal wall expansion for repair of incisional herniae: a systematic review.

    Science.gov (United States)

    Alam, N N; Narang, S K; Pathak, S; Daniels, I R; Smart, N J

    2016-04-01

    To systematically review the available literature regarding methods for abdominal wall expansion and compare the outcome of primary fascial closure rates. A systematic search of Pubmed and Embase databases was conducted using the search terms "Abdominal wall hernia", "ventral hernia", "midline hernia", "Botulinum toxin", "botox", "dysport", "progressive preoperative pneumoperitoneum", and "tissue expanders". Study quality was assessed using the Methodological Index for Non-Randomised Studies. 21 of the 105 studies identified met the inclusion criteria. Progressive preoperative pneumoperitoneum (PPP) was performed in 269 patients across 15 studies with primary fascial closure being achieved in 226 (84%). 16 patients had a recurrence (7.2%) and the complication rate was 12% with 2 reported mortalities. There were 4 studies with 14 patients in total undergoing abdominal wall expansion using tissue expanders with a fascial closure rate of 92.9% (n = 13). A recurrence rate of 10.0% (n = 1) was reported with 1 complication and no mortalities. Follow up ranged from 3 to 36 months across the studies. There were 2 studies reporting the use of botulinum toxin with 29 patients in total. A primary fascial closure rate of 100% (n = 29) was demonstrated although a combination of techniques including component separation and Rives-Stoppa repair were used. There were no reported complications related to the use of Botulinum Toxin. However, the short-term follow up in many cases and the lack of routine radiological assessment for recurrence suggests that the recurrence rate has been underestimated. PPP, tissue expanders and Botulinum toxin are safe and feasible methods for abdominal wall expansion prior to incisional hernia repair. In combination with existing techniques for repair, these methods may help provide the crucial extra tissue mobility required to achieve primary closure.

  7. CD1d deficiency inhibits the development of abdominal aortic aneurysms in LDL receptor deficient mice.

    Directory of Open Access Journals (Sweden)

    Gijs H M van Puijvelde

    Full Text Available An abdominal aortic aneurysm (AAA is a dilatation of the abdominal aorta leading to serious complications and mostly to death. AAA development is associated with an accumulation of inflammatory cells in the aorta including NKT cells. An important factor in promoting the recruitment of these inflammatory cells into tissues and thereby contributing to the development of AAA is angiotensin II (Ang II. We demonstrate that a deficiency in CD1d dependent NKT cells under hyperlipidemic conditions (LDLr-/-CD1d-/- mice results in a strong decline in the severity of angiotensin II induced aneurysm formation when compared with LDLr-/- mice. In addition, we show that Ang II amplifies the activation of NKT cells both in vivo and in vitro. We also provide evidence that type I NKT cells contribute to AAA development by inducing the expression of matrix degrading enzymes in vSMCs and macrophages, and by cytokine dependently decreasing vSMC viability. Altogether, these data prove that CD1d-dependent NKT cells contribute to AAA development in the Ang II-mediated aneurysm model by enhancing aortic degradation, establishing that therapeutic applications which target NKT cells can be a successful way to prevent AAA development.

  8. Repair of aortic arch aneurysm under cardiopulmonary bypass and deep hypothermia with low flow: A case report

    Directory of Open Access Journals (Sweden)

    Md. Rezwanul Hoque

    2016-07-01

    Full Text Available Aortic arch surgery is the challenging and most difficult surgery among the cardiovascular operations. Cerebral and spinal complications are the most feared and common complications of aortic arch surgery. With best available techniques for cerebral and spinal protection, anesthetic management and good post-operative care; aortic arch surgery is considerably safer nowadays and satisfactory results can be achieved in most patients. Also, selecting the sites for arterial cannulation to maintain whole body circulation, during isolation of the aortic arch to operate on it, need proper anatomical description of the extent of the aneurysm. This is also achievable by the availability of the imaging techniques like Computed Tomog­raphy (CT with or without contrast, CT Angiography (CTA and Magnetic Resonance Imaging (MRI. We are reporting a case of aneurysm of aortic arch in a young adult, who had undergone repair under cardiopulmonary bypass and deep hypothermia with low flow and had normal convalescence without any cerebral or spinal complications.

  9. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  10. Reported high salt intake is associated with increased prevalence of abdominal aortic aneurysm and larger aortic diameter in older men.

    Directory of Open Access Journals (Sweden)

    Jonathan Golledge

    Full Text Available Salt intake has been implicated in the pathogenesis of abdominal aortic aneurysm (AAA through studies in rodent models but not previously studied in humans. The aim of this study was to examine the association between reported addition of salt to food and the prevalence of AAA.A risk factor questionnaire which contained a question about salt intake was included as part of a population screening study for AAA in 11742 older men. AAA presence was assessed by abdominal ultrasound imaging using a reproducible protocol.The prevalence of AAA was 6.9, 8.5 and 8.6% in men who reported adding salt to food never, sometimes and always, respectively, p = 0.005. Addition of salt to food sometimes (odds ratio [OR]: 1.22, 95% confidence interval [CI]: 1.03-1.44 or always (OR: 1.23, 95% CI 1.04-1.47 was independently associated with AAA after adjustment for other risk factors including age, waist-hip ratio, blood pressure, history of hypertension, high cholesterol, angina, diabetes, myocardial infarction and stroke. Salt intake was also independently associated with aortic diameter (beta 0.023, p = 0.012. In men with no prior history of hypertension, high cholesterol, angina, myocardial infarction or stroke (n = 4185, the association between addition of salt to food sometimes (OR: 1.41, 95% CI 0.96-2.08 or always (OR: 1.52, 95% CI 1.04-2.22 and AAA remained evident.Reported salt intake is associated with AAA in older men. Additional studies are needed to determine whether reducing salt intake would protect against AAA.

  11. Aortic regurgitation after valve-sparing aortic root replacement: modes of failure.

    Science.gov (United States)

    Oka, Takanori; Okita, Yutaka; Matsumori, Masamichi; Okada, Kenji; Minami, Hitoshi; Munakata, Hiroshi; Inoue, Takeshi; Tanaka, Akiko; Sakamoto, Toshihito; Omura, Atsushi; Nomura, Takuo

    2011-11-01

    Despite the positive clinical results of valve-sparing aortic root replacement, little is known about the causes of reoperations and the modes of failure. From October 1999 to June 2010, 101 patients underwent valve-sparing aortic root replacement using the David reimplantation technique. The definition of aortic root repair failure included the following: (1) intraoperative conversion to the Bentall procedure; (2) reoperation performed because of aortic regurgitation; and (3) aortic regurgitation equal to or greater than a moderate degree at the follow-up. Sixteen patients were considered to have repair failure. Three patients required intraoperative conversion to valve replacement, 3 required reoperation within 3 months, and another 8 required reoperation during postoperative follow-up. At initial surgery 5 patients had moderate to severe aortic regurgitation, 6 patients had acute aortic dissections, 3 had Marfan syndrome, 2 had status post Ross operations, 3 had bicuspid aortic valves, and 1 had aortitis. Five patients had undergone cusp repair, including Arantius plication in 3 and plication at the commissure in 2. The causes of early failure in 6 patients included cusp perforation (3), cusp prolapse (3), and severe hemolysis (1). The causes of late failure in 10 patients included cusp prolapse (4), commissure dehiscence (3), torn cusp (2), and cusp retraction (1). Patients had valve replacements at a mean of 23 ± 20.9 months after reimplantation and survived. Causes of early failure after valve-sparing root replacement included technical failure, cusp lesions, and steep learning curve. Late failure was caused by aortic root wall degeneration due to gelatin-resorcin-formalin glue, cusp degeneration, or progression of cusp prolapse. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Lap-belt syndrome: management of aortic intimal dissection in a 7-year-old child with a constellation of injuries

    International Nuclear Information System (INIS)

    Khanna, Paritosh C.; Bulas, Dorothy I.; Rothenbach, Patricia; Guzzetta, Philip C.

    2007-01-01

    We present a case of lap-belt motor vehicle injury in a 7-year-old male who was admitted with abdominal ecchymoses and pain with associated aortic intimal flap, bowel injury, hemoperitoneum, and retroperitoneal hematoma at initial imaging with CT. Most of these findings were confirmed at subsequent laparotomy, and the patient underwent operative repair of bowel injuries. His aortic intimal flap was followed with US and color Doppler imaging during which time he was treated conservatively until there was sonographic evidence of intimal healing. This patient illustrates a multimodality approach to imaging and conservative management. (orig.)

  13. Predictive Factors for Mortality and Morbidity of Ruptured Abdominal Aortic Aneurysm Repair

    Directory of Open Access Journals (Sweden)

    Manabu Shiraishi

    2012-04-01

    Conclusions: Emergency open repair can be safely performed in patients for infrarenal rAAA. In particular, we identified specific independent predictive factors of clinical examination and laboratory studies for mortality, major morbidity and renal insufficiency. [Arch Clin Exp Surg 2012; 1(2.000: 94-101

  14. Screening of COPD patients for abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Flessenkaemper IH

    2015-06-01

    Full Text Available Ingo H Flessenkaemper,1 Robert Loddenkemper,2 Stephanie Roll,3 Kathrin Enke-Melzer,1 Henrik Wurps,2 Torsten T Bauer21Department for Vascular Medicine, 2Department of Pneumology, Helios Klinikum Emil von Behring, Berlin, Germany; 3Institute for Social Medicine, Epidemiology and Health Economics, Charité – Universitätsmedizin Berlin, Berlin, GermanyPurpose: Screening for abdominal aortic aneurysm (AAA in “men aged over 65 years who have ever smoked” is a recommended policy. To reduce the number of screenings, it may be of value to define subgroups with a higher prevalence of AAA. Since chronic obstructive pulmonary disease (COPD and AAA are associated with several common risk factors, this study investigates the prevalence of AAA in COPD patients.Patients and methods: Patients with COPD were identified via the hospital information system. Inclusion criteria were: COPD stage I–IV, ability to give full consent, and age >18 years; exclusion criteria were: patient too obese for an ultrasound check, previously diagnosed AAA, prior surgery for AAA, or ethical grounds such as concomitant advanced malignant or end-stage disease. The primary endpoint of the study was an aortic diameter measured by ultrasound of ≥30 mm. Defined secondary endpoints were evaluated on the basis of medical records and interviews.Results: Of the 1,180 identified COPD patients, 589 were included in this prospective study. In 22 patients (3.70%, the aortic diameter was ≥30 mm, representing an AAA prevalence of 6.72% among males aged >65 years. The risk of AAA increased with the following comorbidities/risk factors: male sex (odds ratio [OR] 2.98, coronary heart disease (OR 2.81, peripheral arterial occlusive disease (OR 2.47, hyperlipoproteinemia (OR 2.77, AAA in the family history (OR 3.95, and COPD stage I/II versus IV (OR 1.81.Conclusion: The overall AAA prevalence of 3.7% in our group of COPD patients is similar to that of the general population aged >65

  15. Anatomic changes of target vessels after fenestrated and branched aortic aneurysm repair.

    Science.gov (United States)

    Kalder, J; Keschenau, P; Tamm, M; Jalaie, H; Jacobs, M J; Greiner, A

    2014-04-01

    Objective of this study was to evaluate the anatomic changes of the stented target vessels after endovascular repair of complex aortic aneurysms. Between July 2011 and December 2013, 53 aortic aneurysms were treated in our department with fenestrated and branched stent-graft devices. Forty-two of these patients were pre- and postoperatively scanned with a high resolution computer tomography (CT) (Cook Zenith® fenestrated or branched, Australia Pty. Ltd., Brisbane, Australia: N.=19; AnacondaTM fenestrated, Vascutek, Glasgow, Scotland, UK: N.=23). The other 11 out of the 53 patients did not receive a CT scan, because of a pre-existing renal failure. In the CT scans we retrospectively evaluated the anatomic vessel deviation at the origin of the target vessel and the vessel shift distal to the stent. For the first measurement the CT scans were loaded into OsiriX MD®, and the pre- and postoperative angles of the target vessels were measured and subtracted. For matching, the CT-scans were normalized at vertebral body lumbar 2. The second measured angle was the maximal measured angle distal to the target vessel stent-graft. Altogether, 113 target vessels were stented (celiac trunk [CT] 15, superior mesenteric arteries [SMA] 26, renal arteries [RA] 72), with 97 balloon-expandable PTFE stents: 90 Atrium V12 (Maquet Getinge group, Hudson, NH, USA), 7 BeGrafts (Bentley InnoMed, Hechingen, Germany) and 16 self-expandable fluency PTFE stents (Bard, Karlsruhe, Germany). The mean anatomic deviation at the target vessel origin was 28±17.3 and the mean vessel shift distal to the stent was 36.3±18.8. There were no significant differences between the main device and the target vessel stent types. Fenestrated and branched stent-graft solutions for aortic aneurysm repair induce changes of the target vessel anatomy. We did not observe significant differences between the several devices.

  16. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  17. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  18. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  19. Effect of Pregnancy on Ventricular and Aortic Dimensions in Repaired Tetralogy of Fallot.

    Science.gov (United States)

    Cauldwell, Matthew; Quail, Michael A; Smith, Gillian S; Heng, Ee Ling; Ghonim, Sarah; Uebing, Anselm; Swan, Lorna; Li, Wei; Patel, Roshni R; Pennell, Dudley J; Steer, Philip J; Johnson, Mark R; Gatzoulis, Michael A; Babu-Narayan, Sonya V

    2017-07-23

    The aim was to assess whether cardiovascular adaptation to pregnancy in women with repaired tetralogy of Fallot (TOF) adversely affects hemodynamic stability, in particular with respect to right ventricular (RV) dilatation, pulmonary regurgitation, or aortic root dilatation. This was a retrospective cohort study of women with repaired TOF with paired cardiovascular magnetic resonance scans before and after their first pregnancy (baseline RV end systolic volume index 49 mL/m 2 and RV end diastolic volume index 118 mL/m 2 ) matched with a comparison group of nulliparous women with TOF. Cases were matched for age at baseline cardiovascular magnetic resonance scan, time between follow-up of cardiovascular magnetic resonance scans, QRS duration, RV ejection fraction, and indexed RV end systolic and diastolic volume at baseline. Effect of pregnancy and time on parameters was assessed using mixed-effects modelling. Nineteen women with repaired TOF who had completed their first pregnancy were identified and matched with 38 nulliparous women. We observed no deleterious effects of pregnancy on RV volumes, aortic dimensions, or exercise data. There was an effect of pregnancy observed in both left ventricular end diastolic volume and left ventricular stroke volume, consistent with a sustained small increase in left ventricular stroke volume attributed to pregnancy (53-55 mL/m 2 ). Women with repaired TOF and with mild-to-moderate RV dilatation considering pregnancy can be reassured that pregnancy is unlikely to cause deterioration in their cardiovascular status. We recommend that women are routinely assessed and followed up before and after pregnancy and that prepregnancy counseling is tailored to their individual clinical status. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  20. Transaortic edge-to-edge mitral valve repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic root/valve intervention.

    Science.gov (United States)

    Choudhary, Shiv Kumar; Abraham, Atul; Bhoje, Amol; Gharde, Parag; Sahu, Manoj; Talwar, Sachin; Airan, Balram

    2017-11-01

    The present study evaluates the feasibility, safety, and efficacy of edge-to-edge repair for moderate secondary/functional mitral regurgitation in patients undergoing aortic valve/root interventions. Sixteen patients underwent transaortic edge-to-edge mitral valve repair. Mitral regurgitation was 2+ in 8 patients and 3+ in 6 patients. Two patients in whom cardiac arrest developed preoperatively had severe (4+) mitral regurgitation. Patients underwent operation for severe aortic regurgitation ± aortic root lesions. The mean left ventricular systolic and diastolic diameters were 51.5 ± 12.8 mm and 70.7 ± 10.7 mm, respectively. Left ventricular ejection fraction ranged from 20% to 60%. Primary surgical procedure included Bentall's ± hemiarch replacement in 10 patients, aortic valve replacement in 5 patients, and noncoronary sinus replacement with aortic valve repair in 1 patient. Severity of mitral regurgitation decreased to trivial or zero in 13 patients, 1+ in 2 patients, and 2+ in 1 patient. There were no gradients across the mitral valve in 9 patients, less than 5 mm Hg in 6 patients, and 9 mm Hg in 1 patient. There was no operative mortality. Follow-up ranged from 2 weeks to 54 months. Echocardiography showed trivial or no mitral regurgitation in 12 patients, 1+ in 2 patients, and 2+ in 2 patients. None of the patients had significant mitral stenosis. The mean left ventricular systolic and diastolic diameters decreased to 40.5 ± 10.3 mm and 58.7 ± 11.6 mm, respectively. Ejection fraction also improved slightly (22%-65%). Transaortic edge-to-edge mitral valve repair is a safe and effective technique to abolish secondary/functional mitral regurgitation. However, its impact on overall survival needs to be studied. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  1. Hypercholesterolemia Induced by a PCSK9 Gain-of-Function Mutation Augments Angiotensin II-Induced Abdominal Aortic Aneurysms in C57BL/6 Mice-Brief Report.

    Science.gov (United States)

    Lu, Hong; Howatt, Deborah A; Balakrishnan, Anju; Graham, Mark J; Mullick, Adam E; Daugherty, Alan

    2016-09-01

    Gain-of-function mutations of PCSK9 (proprotein convertase subtilisin/kexin type 9) lead to hypercholesterolemia. This study was to determine whether infection of normocholesterolemic mice with an adeno-associated viral (AAV) vector expressing a gain-of-function mutation of mouse PCSK9 increased angiotensin II (AngII)-induced abdominal aortic aneurysms. In an initial study, male C57BL/6 mice were injected intraperitoneally with either an empty vector or PCSK9 gain-of-function mutation (D377Y). AAV at 3 doses and fed a saturated fat-enriched diet for 6 weeks. Two weeks after AAV injection, mice were infused with AngII for 4 weeks. Plasma PCSK9 concentrations were increased dose dependently in mice injected with AAV containing PCSK9D377Y mutation and positively associated with elevations of plasma cholesterol concentrations. Infection with intermediate and high doses of PCSK9D377Y.AAV led to equivalent increases of maximal width of abdominal aortas in C57BL/6 mice infused with AngII. Therefore, the intermediate dose was used in subsequent experiments. We then determined effects of PCSK9D377Y.AAV infection on 5 normolipidemic mouse strains, demonstrating that C57BL/6 mice were the most susceptible to this AAV infection. PCSK9D377Y.AAV infected male C57BL/6 mice were also compared with age-matched male low-density lipoprotein receptor(-/-) mice. Although plasma cholesterol concentrations were lower in mice infected with PCSK9D377Y.AAV, these mice had equivalent abdominal aortic aneurysmal formation, compared to low-density lipoprotein receptor(-/-) mice. In a separate study, reduced plasma PCSK9 concentrations by PCSK9 antisense oligonucleotides in male low-density lipoprotein receptor(-/-) mice did not influence AngII-induced abdominal aortic aneurysms. AAV-mediated infection with a mouse PCSK9 gain-of-function mutation is a rapid, easy, and efficient approach for inducing hypercholesterolemia and promoting abdominal aortic aneurysms in C57BL/6 mice infused with Ang

  2. High risk endovascular aneurysm repair: a case report.

    Science.gov (United States)

    De Silva, Samanthi

    2017-10-01

    Mr AB is a 66-year old gentleman who presented for elective endovascular aneurysm repair (EVAR) following a routine screening scan identifying a 5.5cm abdominal aortic aneurysm (AAA). He had a past history of chronic obstructive pulmonary disease (COPD) with FEV1/FVC ratio of 48% on pre-assessment. He was hypertensive with a history of ischaemic heart disease (IHD), which has remained asymptomatic following coronary artery bypass grafting (CABG) eight years prior to this presentation. Copyright the Association for Perioperative Practice.

  3. The same sequence variant on 9p21 associates with myocardial infarction, abdominal aortic aneurysm and intracranial aneurysm

    DEFF Research Database (Denmark)

    Helgadottir, Anna; Thorleifsson, Gudmar; Magnusson, Kristinn P

    2008-01-01

    . Here we report that rs10757278-G is associated with, in addition to CAD, abdominal aortic aneurysm (AAA; odds ratio (OR) = 1.31, P = 1.2 x 10(-12)) and intracranial aneurysm (OR = 1.29, P = 2.5 x 10(-6)), but not with T2D. This variant is the first to be described that affects the risk of AAA...

  4. Is there a prospect for hybrid aortic arch surgery?

    Science.gov (United States)

    Bashir, Mohamad; Harky, Amer; Bilal, Haris

    2018-05-16

    The surge of endovascular repair of aortic aneurysm in current modern aortic surgery practice has been the key for surgical management of elective cases of thoracic aortic aneurysms. This has paved way for the combined hybrid approach to be amongst the armamentarium for the management of aortic arch disease. The pivotal understanding of the aortic arch natural history coupled with device technology advancement allowed surgeons insight into delivery of hybrid surgery with acceptable morbidity and mortality results. This review article provides current insights into hybrid technique of aortic arch aneurysm repair and the evidences behind its applicability to arch surgery. It is aimed to highlight the challenges encountered for this innovative approach and correlate its challenges to those that are met by the conventional open aortic arch repair.

  5. Abdominal Aortic Aneurysm

    Science.gov (United States)

    ... AAAs don’t cause symptoms unless they leak, tear, or rupture. If this happens, you may experience: sudden pain in your abdomen, groin, back, legs, or buttocks nausea and vomiting abnormal stiffness in your abdominal muscles problems with urination or bowel movements clammy, sweaty ...

  6. Six years' experience with prostaglandin I2 infusion in elective open repair of abdominal aortic aneurysm: a parallel group observational study in a tertiary referral vascular center.

    LENUS (Irish Health Repository)

    Beirne, Chris

    2008-11-01

    The prostaglandin I(2) (PGI(2)) analogue iloprost, a potent vasodilator and inhibitor of platelet activation, has traditionally been utilized in pulmonary hypertension and off-label use for revascularization of chronic critical lower limb ischemia. This study was designed to assess the effect of 72 hr iloprost infusion on systemic ischemia post-open elective abdominal aortic aneurysm (EAAA) surgery. Between January 2000 and 2007, 104 patients undergoing open EAAA were identified: 36 had juxtarenal, 15 had suprarenal, and 53 had infrarenal aneurysms, with a mean maximal diameter of 6.9 cm. The male-to-female ratio was 2.5:1, with a mean age of 71.9 years. No statistically significant difference was seen between the study groups with regard to age, sex, risk factors, American Society of Anesthesiologists (ASA) grade, or diameter of aneurysm repaired. All emergency, urgent, and endovascular procedures for aneurysms were excluded. Fifty-seven patients received iloprost infusion for 72 hr in the immediate postoperative period compared with 47 patients who did not. Patients were monitored for signs of pulmonary, renal, cardiac, systemic ischemia, and postoperative intensive care unit (ICU) morbidity. Statistically significantly increased ventilation rates (p=0.0048), pulmonary complication rates (p=0.0019), and myocardial ischemia (p=0.0446) were noted in those patients not receiving iloprost. These patients also had significantly higher renal indices including estimate glomerular filtration rate changes (p=0.041) and postoperative urea level rises (p=0.0286). Peripheral limb trashing was noted in five patients (11.6%) in the non-iloprost group compared with no patients who received iloprost. Increased rates of transfusion requirements and bowel complications were noted in those who did not receive iloprost, with their ICU stay greater than twice that of iloprost patients. All-cause morbidity affected 67% of patients not receiving iloprost compared to 40% who did

  7. Various complications of abdominal aortic aneurysm : CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub [The Catholic Univ. of Korea, College of Medicine, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5{+-}3cm, n=3) was significantly larger than that of unruptured AAA(4.9{+-}1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9{+-}1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment.

  8. Various complications of abdominal aortic aneurysm : CT findings

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Byun, Jae Young; Kim, Bum Soo; Kim, Euy Neyung; Yoon, Yeo Dong; Kim, Ki Tae; Lee, Jae Mun; Shinn, Kyung Sub

    1997-01-01

    To evaluate on abdominal CT the type and incidence of various complications of abdominal aortic aneurysm (AAA). Twenty six suspected cases of AAA were confirmed by operation(n=21) and by CT(n=5). The etiology, size, shape and incidence of various complications of AAA were then retrospectively evaluated. In addition, post-operative complications were also evaluated in five cases. The etiology of the aneurysm was atherosclerotic in 18 cases and mycotic in three;it showed the presence of Behcet disease in three cases, of tuberculosis in one, and of Marfan syndrome in one. Among the 18 fusiform AAA, the mean maximum diameter of ruptured AAA(7.5±3cm, n=3) was significantly larger than that of unruptured AAA(4.9±1.6cm, n=15) (p<0.05). The saccular type was much more likely to rupture than the fusiform type(p<0.00001). Out of the eight saccular AAA, seven ruptured ; their mean maximum diameter was 3.9±1.3cm This was significantly smaller than that of ruptured fusiform aneurysm(p<0.05). The most common complication was rupture, and occurred ten of 26 cases(38%). Others included hydronephrosis in three cases, bowel infarction in one, and perianeurysmal retroperitoneal fibrosis in one case. Various post-oper-ative complications developed in five patients; these comprised periprosthetic pseudoaneurysm with hematoma (two cases), bowel ischemia (one), focal renal infarction (one), and secondary aorticoduodenal fistula (one). The most common complication of AAA was rupture, the rate of which was much higher in the saccular type with smaller size than the fusiform type. Other various and uncommon complications were observed. CT was helpful in detecting complications arising from AAA and in planning its treatment

  9. Can early aortic root surgery prevent further aortic dissection in Marfan syndrome?

    Science.gov (United States)

    Shimizu, Hideyuki; Kasahara, Hirofumi; Nemoto, Atsushi; Yamabe, Kentaro; Ueda, Toshihiko; Yozu, Ryohei

    2012-02-01

    We reviewed 50 patients with Marfan syndrome who underwent surgery for aortic root pathologies comprising a root aneurysm without (n = 25; group A) and with (n = 25; group B) dissection. Aortic root repair included Bentall (n = 37) and valve-sparing (n = 13) procedures. Hospital mortality was 4.0%. Twenty-two patients required 36 repeat surgeries on the distal aorta. The main indication for re-intervention was the dilation of the false lumen. In group A, the distal aorta was stable for up to 7 years, but new dissection developed in 5 (33.3%) of the 15 patients who were followed up for >7 years after the root repair. Actuarial survival including operative mortality was 88.1 and 65.0% at 10 and 20 years, respectively; groups A and B did not significantly differ. Rates of freedom from all-cause death, new dissection or repeated aortic surgery were 60.1, 44.5 and 26.0% at 5, 10 and 15 years, respectively. Group A was significantly better than group B. Prophylactic aortic root repair apparently reduces the likelihood of overall adverse events, but it cannot guarantee the prevention of further aortic dissection. A multidisciplinary approach is needed for patients with Marfan syndrome.

  10. Polymorphisms of the matrix metalloproteinase 9 gene and abdominal aortic aneurysm.

    Science.gov (United States)

    Smallwood, L; Allcock, R; van Bockxmeer, F; Warrington, N; Palmer, L J; Iacopetta, B; Golledge, J; Norman, P E

    2008-10-01

    Increased matrix metalloproteinase (MMP) 9 activity has been implicated in the formation of abdominal aortic aneurysm (AAA). The aim was to explore the association between potentially functional variants of the MMP-9 gene and AAA. The -1562C > T and -1811A > T variants of the MMP-9 gene were genotyped in 678 men with an AAA (at least 30 mm in diameter) and 659 control subjects (aortic diameter 19-22 mm) recruited from a population-based trial of screening for AAA. Levels of MMP-9 were measured in a random subset of 300 cases and 84 controls. The association between genetic variants (including haplotypes) and AAA was assessed by multivariable logistic regression. There was no association between the MMP-9-1562C > T (odds ratio (OR) 0.70 (95 per cent confidence interval (c.i.) 0.27 to 1.82)) or -1811A > T (OR 0.71 (95 per cent c.i. 0.28 to 1.85)) genotypes, or the most common haplotype (OR 0.81 (95 per cent c.i. 0.62 to 1.05)) and AAA. The serum MMP-9 concentration was higher in cases than controls, and in minor allele carriers in cases and controls, although the differences were not statistically significant. In this study, the genetic tendency to higher levels of circulating MMP-9 was not associated with AAA.

  11. Can an accessory renal artery be safely covered during endovascular aortic aneurysm repair?

    OpenAIRE

    Antoniou, George A.; Karkos, Christos D.; Antoniou, Stavros A.; Georgiadis, George S.

    2013-01-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether coverage of an accessory renal artery (ARA) in patients undergoing endovascular aortic aneurysm repair (EVAR) is associated with increased risk of renal impairment. Altogether, 106 papers were located using the reported searches, of which 5 represented the best evidence to answer the question. The authors, journal, date and country of publication, study type, patient group studied, rel...

  12. Surgery of abdominal aortic aneurysm associated with coronary artery disease. Simultaneous or two staged operation

    International Nuclear Information System (INIS)

    Tanaka, Hiroyuki; Narisawa, Takashi; Mori, Takanobu; Masuda, Mikio; Kishi, Daijirou; Suzuki, Takashi; Takaba, Toshihiro

    2003-01-01

    Coronary artery disease (CAD) was evaluated by noninvasive examination in abdominal aortic aneurysm (AAA) patients. A simultaneous operation or a 2-staged operation was performed depending on the seriousness of the condition when both diseases were combined. A total of 36 patients underwent elective repair of AAA between 1996 and 2001. Coronary angiography (CAG) was performed only in patients with suspected CAD by dipyridamole myocardial scintigraphy. Significant CAD was found in 8 patients. Simultaneous operation was performed in 4 patients, and off-pump coronary artery bypass grafting (OPCAB) was performed in all cases of simultaneous operation. In 4 patients receiving 2-staged operations, 1 standard coronary artery bypass grafting (CABG), 1 OPCAB and 2 percutaneous transluminal coronary angioplasties (PTCA) were performed prior to AAA surgery. Twenty-eight patients underwent only AAA operation. Though there were no incidents of perioperative myocardial infarction or cardiac related deaths in this group, 2 patients died due to other causes (hemorrhage and duodenal perforation). In the 8 patients associated with CAD, 1 patient died of myonephrotic metabolic syndrome (MNMS) after simultaneous operation. The other 7 patients revived their social function soon of the discharge. Dipyridamole cardiac scintigraphy was considered to be an effective examination for evaluation of CAD in AAA patients. There was no need to perform CAG in all AAA patients. The policy of choosing simultaneous operation or 2-staged operation according to the seriousness of the 2 diseases seemed to be appropriate. (author)

  13. Determining the influence of calcification on the failure properties of abdominal aortic aneurysm (AAA) tissue.

    Science.gov (United States)

    O'Leary, Siobhan A; Mulvihill, John J; Barrett, Hilary E; Kavanagh, Eamon G; Walsh, Michael T; McGloughlin, Tim M; Doyle, Barry J

    2015-02-01

    Varying degrees of calcification are present in most abdominal aortic aneurysms (AAAs). However, their impact on AAA failure properties and AAA rupture risk is unclear. The aim of this work is evaluate and compare the failure properties of partially calcified and predominantly fibrous AAA tissue and investigate the potential reasons for failure. Uniaxial mechanical testing was performed on AAA samples harvested from 31 patients undergoing open surgical repair. Individual tensile samples were divided into two groups: fibrous (n=31) and partially calcified (n=38). The presence of calcification was confirmed by fourier transform infrared spectroscopy (FTIR). A total of 69 mechanical tests were performed and the failure stretch (λf), failure stress (σf) and failure tension (Tf) were recorded for each test. Following mechanical testing, the failure sites of a subset of both tissue types were examined using scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) to investigate the potential reasons for failure. It has been shown that the failure properties of partially calcified tissue are significantly reduced compared to fibrous tissue and SEM and EDS results suggest that the junction between a calcification deposit and the fibrous matrix is highly susceptible to failure. This study implicates the presence of calcification as a key player in AAA rupture risk and provides further motivation for the development of non-invasive methods of measuring calcification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Epidemiology of abdominal aortic aneurysms in the Asian community.

    Science.gov (United States)

    Spark, J I; Baker, J L; Vowden, P; Wilkinson, D

    2001-03-01

    Studies relating to the ethnic origin of patients with an abdominal aortic aneurysm (AAA) are few and are mainly concerned with the differences between black and white Americans. The purpose of this study was to determine whether the incidence of AAA among the Asian population of Bradford is different from that in the Caucasian population. A retrospective study of patients with an AAA was carried out between 1990 and 1997 using data collected by the Patient Administrative Service, personal databases of the vascular consultants and theatre records. Information about the ethnic composition of the population of Bradford was obtained from the 1991 national census. Demographic data, including ethnic origin and clinical details, were obtained from patient notes. Two hundred and thirty-three patients with an AAA were identified during the study interval. The Asian population comprised 14.0 per cent of the total population of Bradford. Twenty-eight AAAs would be expected per year. All of the aneurysms identified occurred in the Caucasian population and none in the Asian community. These early results suggest that AAA is rare among the Asian population.

  15. Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Goudeketting, Seline R; Heinen, Stefan G H; Ünlü, Çağdaş; van den Heuvel, Daniel A F; de Vries, Jean-Paul P M; van Strijen, Marco J; Sailer, Anna M

    2017-08-01

    To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15-18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.

  16. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  17. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  18. Metabolic and hemodynamic effects of saline infusion to maintain volemia on temporary abdominal aortic occlusion

    Directory of Open Access Journals (Sweden)

    Fábio Ferreira Amorim

    2002-10-01

    Full Text Available OBJECTIVE: To analyze hemodynamic and metabolic effects of saline solution infusion in the maintenance of blood volume in ischemia-reperfusion syndrome during temporary abdominal aortic occlusion in dogs. METHODS: We studied 20 dogs divided into 2 groups: the ischemia-reperfusion group (IRG, n=10 and the ischemia-reperfusion group with saline solution infusion aiming at maintaining mean pulmonary arterial wedge pressure between 10 and 20 mmHg (IRG-SS, n=10. All animals were anesthetized with sodium thiopental and maintained on spontaneous ventilation. Occlusion of the supraceliac aorta was obtained with inflation of a Fogarty catheter inserted through the femoral artery. After 60 minutes of ischemia, the balloon was deflated, and the animals were observed for another 60 minutes of reperfusion. RESULTS: IRG-SS dogs did not have hemodynamic instability after aortic unclamping, and the mean systemic blood pressure and heart rate were maintained. However, acidosis worsened, which was documented by a greater reduction of arterial pH that occurred especially due to the absence of a respiratory response to metabolic acidosis that was greater with the adoption of this procedure. CONCLUSION: Saline solution infusion to maintain blood volume avoided hemodynamic instability after aortic unclamping. This procedure, however, caused worsening in metabolic acidosis in this experimental model.

  19. Low prevalence of abdominal aortic aneurysm in the Seychelles population aged 50 to 65 years.

    Science.gov (United States)

    Yerly, Patrick; Madeleine, George; Riesen, Walter; Bovet, Pascal

    2013-03-01

    The prevalence of abdominal aortic aneurysm (AAA) and its risk factors are well known in Western countries but few data are available from low- and middle- income countries. We are not aware of systematically collected population- based data on AAA in the African region. We evaluated the prevalence of AAA in a population- based cardiovascular survey conducted in the Republic of Seychelles in 2004 (Indian Ocean, African region). Among the 353 participants aged 50 to 64 years and screened with ultrasound, the prevalence of AAA was 0.3% (95% CI: 0- 0.9) and the prevalence of ectatic dilatations of the abdominal aorta was 1.5% (95% CI: 0.2- 2.8). The prevalence of AAA in the general population seemed lower in Seychelles than in Western countries, despite a high prevalence in Seychelles of risk factors of AAA, such as smoking (in men), high blood pressure and hypercholesterolaemia.

  20. Dilatation of the ascending aorta is associated with presence of aortic regurgitation in patients after repair of tetralogy of Fallot

    Science.gov (United States)

    Ordovas, Karen Gomes; Keedy, Alexander; Naeger, David M.; Kallianos, Kimberly; Foster, Elyse; Liu, Jing; Saloner, David; Hope, Michael D.

    2016-01-01

    To evaluate the association between aortic morphology and elasticity with aortic regurgitation in surgically corrected of tetralogy of Fallot (TOF) patients. We retrospectively identified 72 consecutive patients with surgically corrected TOF and 27 healthy controls who underwent cardiac MRI evaluation. Velocity-encoded cine MRI was used to quantify degree of aortic regurgitation (AR) in TOF patients. Ascending aorta diameters were measured at standard levels on MRA images. Aortic pulse-wave velocity (PWV) was quantified with MRI. Morphological and functional MRI variables were compared between groups of TOF patients with and without clinically relevant AR and controls. The association between aortic morphology and elasticity with the presence of AR was evaluated using univariate and multivariate logistic regression. The majority of TOF patients had only trace AR. Nine TOF patients (12 %) had an AR fraction higher than 15 %. Indexed aorta diameter at the sinotubular junction (p = 0.007), at the RPA level (p = 0.006), and low left ventricular ejection fraction (LVEF) (p = 0.015) showed the strongest associations with the presence of at least mild AR, which persisted after controlling for age and gender. Increased ascending aorta dimension is associated with AR in patients after repair of TOF. LVEF was also low in the group of patients with relevant AR compared to those without, suggesting even mild to moderate AR may contribute to LV dysfunction in these patients. Enlarged ascending aorta may be an indication for precise quantification of regurgitant fraction with MRI, since symptomatic patients may need aortic valve repair when moderate regurgitation is present. PMID:27240599

  1. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  2. Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation

    International Nuclear Information System (INIS)

    Frauenfelder, Thomas; Lotfey, Mourad; Boehm, Thomas; Wildermuth, Simon

    2006-01-01

    The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement

  3. Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

    Energy Technology Data Exchange (ETDEWEB)

    Dudeck, O., E-mail: oliver.dudeck@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Schnapauff, D. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Herzog, L.; Löwenthal, D.; Bulla, K.; Bulla, B. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Halloul, Z.; Meyer, F. [University of Magdeburg, Department of General, Visceral and Vascular Surgery (Germany); Pech, M. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Gebauer, B. [Charité Universitätsmedizin Berlin, Department of Radiology (Germany); Ricke, J. [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany)

    2015-02-15

    PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

  4. Successful surgical repair of acute type A aortic dissection without the use of blood products.

    Science.gov (United States)

    Papalexopoulou, N; Attia, R Q; Bapat, V N

    2013-10-01

    We report successful surgical treatment of type A aortic dissection in a Jehovah's Witness without the use of any blood products. An interposition graft replacement of the ascending aorta was carried out. This was under right axillo-atrial cardiopulmonary bypass with antegrade cerebral perfusion via right a subclavian and left carotid cannula for 24 minutes at 28°C. Body temperature was kept at 32°C throughout. Autologous transfusion was deployed using cell salvage and a preoperative haemodilution technique. The patient was given tranexamic acid, desmopressin, recombinant factor VIIa, folic acid and epoetin alfa. Patients who object to transfusion represent a significant challenge, especially those who are at a high risk of coagulopathy associated with inherent aortic dissection leading to perturbed haemodynamics, cardiopulmonary bypass and hypothermic circulatory arrest. Type A aortic dissection repair is possible in patients refusing the use of blood products with blood salvage techniques and synthetic products that can limit the risk of bleeding. Minimal hypothermia is vital to preserve platelet function and avoid coagulopathy. Thus, a combination of normothermic/minimal hypothermia and antegrade cerebral protection with a blood conservation strategy can be deployed for a successful surgical outcome in aortic dissection without transfusion.

  5. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  6. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2003-01-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  7. Genome-wide association study identifies a sequence variant within the DAB2IP gene conferring susceptibility to abdominal aortic aneurysm

    NARCIS (Netherlands)

    Gretarsdottir, Solveig; Baas, Annette F.; Thorleifsson, Gudmar; Holm, Hilma; den Heijer, Martin; de Vries, Jean-Paul P. M.; Kranendonk, Steef E.; Zeebregts, Clark J. A. M.; van Sterkenburg, Steven M.; Geelkerken, Robert H.; van Rij, Andre M.; Williams, Michael J. A.; Boll, Albert P. M.; Kostic, Jelena P.; Jonasdottir, Adalbjorg; Jonasdottir, Aslaug; Walters, G. Bragi; Masson, Gisli; Sulem, Patrick; Saemundsdottir, Jona; Mouy, Magali; Magnusson, Kristinn P.; Tromp, Gerard; Elmore, James R.; Sakalihasan, Natzi; Limet, Raymond; Defraigne, Jean-Olivier; Ferrell, Robert E.; Ronkainen, Antti; Ruigrok, Ynte M.; Wijmenga, Cisca; Grobbee, Diederick E.; Shah, Svati H.; Granger, Christopher B.; Quyyumi, Arshed A.; Vaccarino, Viola; Patel, Riyaz S.; Zafari, A. Maziar; Levey, Allan I.; Austin, Harland; Girelli, Domenico; Pignatti, Pier Franco; Olivieri, Oliviero; Martinelli, Nicola; Malerba, Giovanni; Trabetti, Elisabetta; Becker, Lewis C.; Becker, Diane M.; Reilly, Muredach P.; Rader, Daniel J.; Mueller, Thomas; Dieplinger, Benjamin; Haltmayer, Meinhard; Urbonavicius, Sigitas; Lindblad, Bengt; Gottsater, Anders; Gaetani, Eleonora; Pola, Roberto; Wells, Philip; Rodger, Marc; Forgie, Melissa; Langlois, Nicole; Corral, Javier; Vicente, Vicente; Fontcuberta, Jordi; Espana, Francisco; Grarup, Niels; Jorgensen, Torben; Witte, Daniel R.; Hansen, Torben; Pedersen, Oluf; Aben, Katja K.; de Graaf, Jacqueline; Holewijn, Suzanne; Folkersen, Lasse; Franco-Cereceda, Anders; Eriksson, Per; Collier, David A.; Stefansson, Hreinn; Steinthorsdottir, Valgerdur; Rafnar, Thorunn; Valdimarsson, Einar M.; Magnadottir, Hulda B.; Sveinbjornsdottir, Sigurlaug; Olafsson, Isleifur; Magnusson, Magnus Karl; Palmason, Robert; Haraldsdottir, Vilhelmina; Andersen, Karl; Onundarson, Pall T.; Thorgeirsson, Gudmundur; Kiemeney, Lambertus A.; Powell, Janet T.; Carey, David J.; Kuivaniemi, Helena; Lindholt, Jes S.; Jones, Gregory T.; Kong, Augustine; Blankensteijn, Jan D.; Matthiasson, Stefan E.; Thorsteinsdottir, Unnur; Stefansson, Kari

    We performed a genome-wide association study on 1,292 individuals with abdominal aortic aneurysms (AAAs) and 30,503 controls from Iceland and The Netherlands, with a follow-up of top markers in up to 3,267 individuals with AAAs and 7,451 controls. The A allele of rs7025486 on 9q33 was found to

  8. Limitations of Online Information on Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Carolyn G. Goldberg

    2010-01-01

    Full Text Available Background. Patients with AAA face a complex decision, and knowledge of the risks and benefits of each treatment option is essential to informed decision-making. Here we assess the current information on the internet accessible to patients regarding the management of AAA. Study Design. We performed a search on Google using the keywords “abdominal aortic aneurysm” and reviewed the top 50 web sites. We focused on information related to treatment options and alternatives to treatment and the risks of each option. Results. Twenty-seven websites were included in the study. Nearly 30% of websites discussed the risk of mortality and myocardial infarction after open surgery, compared to only 7.4% for both risks after EVAR. Other complications were listed by fewer websites. Fifty-five percent of websites reported that patients had a faster recovery following EVAR, but only 18.5% mentioned the risk of reintervention after EVAR or the need for long-term surveillance with CT scans. Conclusions. While most websites included descriptive information on AAA and mentioned the potential treatment options available to patients, the discussion of the risks of open surgery and EVAR was inadequate. These results suggest that websites frequently accessed by patients lack important information regarding surgical risk.

  9. Carotid and coronary disease management prior to open and endovascular aortic surgery. What are the current guidelines?

    Science.gov (United States)

    Thompson, J P

    2014-04-01

    Several bodies produce broadly concurring and updated guidelines for the evaluation and treatment of cardiovascular disease in both surgical and non-surgical patients. Recent developments include revised recommendations on preoperative stress testing, referral for possible coronary revascularization and medical management. It is recognized that non-invasive cardiac tests are relatively poor at predicting perioperative risk, and "prophylactic" coronary revascularization has a limited role. The planned aortic intervention (open or endovascular repair) also influences preoperative management. Patients presenting for elective abdominal aortic aneurysm (AAA) repair should only be referred for cardiological testing if they have active symptoms of coronary artery disease (CAD), known CAD and poor functional exercise capacity, or multiple risk factors for CAD. Coronary revascularization before AAA surgery should be limited to patients with established indications, so cardiac stress testing should only be performed if it would change management i.e. the patient is a candidate for and would benefit from coronary revascularization. When endovascular aortic repair is planned, it is reasonable to proceed to surgery without further cardiac stress testing or evaluation unless otherwise indicated. All non-emergency patients require medical optimization, but perioperative beta blockade benefits only certain patients. Some of the data informing recent guidelines have been questioned and some guidelines are being revised. Current guidelines do not specifically address the management of patients with known or suspected carotid artery disease who may require aortic surgery. For these patients, an individualized approach is required. This review considers recent guidelines. Algorithms for investigation and management based on their recommendations are included.

  10. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  11. Metformin treatment does not affect the risk of ruptured abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Kristensen, Katrine L.; Pottegård, Anton; Hallas, Jesper

    2017-01-01

    Objective: Diabetes counteracts formation and rupture of abdominal aortic aneurysms, possibly through arterial matrix accumulation. Use of metformin, on the other hand, reduces arterial accumulation of matrix molecules. Consequently, we hypothesized that metformin treatment may reverse...... the protective role of diabetes on the development and course of aneurysms, that is, that metformin would be associated with aneurysm rupture among individuals with diabetes. Methods: Using nationwide Danish registry data, we performed a nested case-control study on the association between long-term use....... In total, 22.4% of the case population were long-term metformin users compared with 28.8% of the controls. We found a statistically nonsignificant protective effect of long-term metformin use toward RAAA with crude odds ratio (OR) of 0.74 (confidence interval, 0.54-1.00). When adjusted for covariates...

  12. Allergic Lung Inflammation Aggravates Angiotensin II-Induced Abdominal Aortic Aneurysms in Mice

    DEFF Research Database (Denmark)

    Liu, Cong-Lin; Wang, Yi; Liao, Mengyang

    2016-01-01

    sensitization and challenge in mice led to the development of allergic lung inflammation (ALI). Subcutaneous infusion of angiotensin II into mice produced AAA. Simultaneous production of ALI in AAA mice doubled abdominal aortic diameter and increased macrophage and mast cell content, arterial media smooth...... and reduced lesion inflammation, plasma IgE, and bronchioalveolar inflammation. Pre-establishment of ALI also increased AAA lesion size, lesion accumulation of macrophages and mast cells, media smooth muscle cell loss, and plasma IgE, reduced plasma interleukin-5, interleukin-13, and transforming growth...... factor-β, and increased bronchioalveolar inflammation. Consequent production of ALI also doubled lesion size of pre-established AAA and increased lesion mast cell and T-cell accumulation, media smooth muscle cell loss, lesion cell proliferation and apoptosis, plasma IgE, and bronchioalveolar inflammation...

  13. Prevalence of abdominal aortic aneurysm (AAA) in a population undergoing computed tomography colonography in Canterbury, New Zealand.

    Science.gov (United States)

    Khashram, M; Jones, G T; Roake, J A

    2015-08-01

    There is compelling level 1 evidence in support of screening men for abdominal aortic aneurysm (AAA) to reduce AAA mortality. However, New Zealand (NZ) lacks data on AAA prevalence, and national screening has not been implemented. The aim of this study was to determine the prevalence of AAA in a population undergoing a computed tomography colonography (CTC) for gastrointestinal symptoms. This was an observational study; all consecutive CTCs performed in three regions of the South Island of NZ over a 4 year period were reviewed. Data on abdominal and thoracic aorta diameters ≥30 mm, and iliac and femoral aneurysms ≥20 mm were recorded. Previous aortic surgical grafts or endovascular stents were also documented. Demographics, survival, and AAA related outcomes were collected and used for analysis. Included were 4,893 scans on 4,644 patients (1,933 men [41.6%], 2,711 women [58.4%]) with a median age of 69.3 years (range 17.0-97.0 years). There were 309 scans on 289 patients (75.4% men) who had either an aneurysm or a previous aortic graft with a median age of 79.6 years (range 57.0-96.0 years). Of these, 223 had a native AAA ≥30 mm. The prevalence of AAA rose with age from 1.3% in men aged 55-64 years, to 9.1% in 65-74 year olds, 16.8% in 75-84 year olds, and 22.0% in ≥85 year olds. The corresponding figures in women were 0.4%, 2%, 3.9%, and 6.2%, respectively. In this observational study, the prevalence of AAA was high and warrants further evaluation. The results acquired help to define a population that may benefit from a national AAA screening programme. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server

    International Nuclear Information System (INIS)

    Neri, Emanuele; Bargellini, Irene; Vignali, Claudio; Bartolozzi, Carlo; Rieger, Michael; Jaschke, Werner; Giachetti, Andrea; Tuveri, Massimiliano

    2005-01-01

    The study describes the application of a web-based software in the planning of the endovascular treatment of abdominal aortic aneurysms (AAA). The software has been developed in the framework of a 2-year research project called Aneurysm QUAntification Through an Internet Collaborative System (AQUATICS); it allows to manage remotely Virtual Reality Modeling Language (VRML) models of the abdominal aorta, derived from multirow computed tomography angiography (CTA) data sets, and to obtain measurements of diameters, angles and centerline lengths. To test the reliability of measurements, two radiologists performed a detailed analysis of multiple 3D models generated from a synthetic phantom, mimicking an AAA. The system was tested on 30 patients with AAA; CTA data sets were mailed and the time required for segmentation and measurement were collected for each case. The Bland-Altman plot analysis showed that the mean intra- and inter-observer differences in measures on phantoms were clinically acceptable. The mean time required for segmentation was 1 h (range 45-120 min). The mean time required for measurements on the web was 7 min (range 4-11 min). The AQUATICS web server may provide a rapid, standardized and accurate tool for the evaluation of AAA prior to the endovascular treatment. (orig.)

  15. Early Results of the PETTICOAT Technique for the Management of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Kotha, Vamshi Krishna; Pozeg, Zlatko I; Herget, Eric J; Moon, Michael C; Appoo, Jehangir J

    2017-08-01

    Conventional surgical techniques for acute Type A aortic dissection (ATAAD) generally fail to address residual dissection in the descending aorta. The persistence of a false lumen is associated with visceral malperfusion in the acute setting and adverse aortic remodeling in the chronic setting. Hybrid aortic arch repair techniques may improve perioperative and long-term mortality by expanding the true lumen and obliterating the false lumen. However, there is a limit to the extent of aortic coverage due to the concomitant risk of spinal cord ischemia. In Type B dissection, the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique, which entails stent graft coverage of the primary intimal tear followed by bare metal stent placement distally, may improve true lumen caliber and promote false lumen thrombosis without increasing the risk of spinal cord ischemia, as intercostal branches remain perfused through the bare metal stents. The technique of hybrid arch with surgical creation of a Dacron landing zone covering a stent graft in the proximal descending aorta and bare metal stents in the thoraco-abdominal aorta is a promising concept in the treatment of ATAAD.

  16. Comparing American, European and Asian practice guidelines for aortic diseases.

    Science.gov (United States)

    Rozado, Jose; Martin, Maria; Pascual, Isaac; Hernandez-Vaquero, Daniel; Moris, Cesar

    2017-05-01

    The aortic disease comprises a group of different pathologies of high prevalence, seriousness and ever changing by the medical and surgical investigations. Therefore cardiovascular scientific societies in USA, Europe and Asia have created Task Force on practice guidelines (PG) to develop, update and revise PG for aortic diseases. These documents issue recommendations on the diagnosis and management of different aortic diseases. The three societies agree on the recommendations about diagnostic tests and on the value of computed tomography and magnetic resonance as the main tools for the diagnosis and follow-up of aortic disease. Concerning to acute aortic syndromes (AAS), American and European GPs recognize intramural hematoma (IMH) as a type of AAS with surgery indication; however Asian guidelines consider IMH a pathological process different from AAS and indicate medical treatment. In thoracic aortic aneurysms (TAA), all express the need for an adequate control of cardiovascular risk factors, emphasizing strict control of blood pressure, smoking cessation and recommend the use of beta-blockers and statins. The threshold for asymptomatic repair is 5.5 cm in European and American and 6 cm for Asian PG, with lower thresholds in Marfan and bicuspid aortic valve (BAV). As regards the abdominal aortic aneurysms (AAA), the PGs recognize the adequate control of cardiovascular risk factors, but there are differences in class of recommendation on statins, angiotensin-converting enzyme inhibitors or beta-blockers to prevent progression of AAA. For intervention, the threshold diameter in asymptomatic is 5.5 cm but can be reduced to 5 cm in women as recommended by Asian PG. Moreover the specific diseases such as Marfan, BAV, pregnancy or atherosclerosis aortic present specific recommendations with small differences between PGs. In conclusion, PGs are interesting and appropriate documents at present. They issue recommendations based on evidence that help the clinician and

  17. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks.

    Science.gov (United States)

    López-Linares, Karen; Aranjuelo, Nerea; Kabongo, Luis; Maclair, Gregory; Lete, Nerea; Ceresa, Mario; García-Familiar, Ainhoa; Macía, Iván; González Ballester, Miguel A

    2018-05-01

    Computerized Tomography Angiography (CTA) based follow-up of Abdominal Aortic Aneurysms (AAA) treated with Endovascular Aneurysm Repair (EVAR) is essential to evaluate the progress of the patient and detect complications. In this context, accurate quantification of post-operative thrombus volume is required. However, a proper evaluation is hindered by the lack of automatic, robust and reproducible thrombus segmentation algorithms. We propose a new fully automatic approach based on Deep Convolutional Neural Networks (DCNN) for robust and reproducible thrombus region of interest detection and subsequent fine thrombus segmentation. The DetecNet detection network is adapted to perform region of interest extraction from a complete CTA and a new segmentation network architecture, based on Fully Convolutional Networks and a Holistically-Nested Edge Detection Network, is presented. These networks are trained, validated and tested in 13 post-operative CTA volumes of different patients using a 4-fold cross-validation approach to provide more robustness to the results. Our pipeline achieves a Dice score of more than 82% for post-operative thrombus segmentation and provides a mean relative volume difference between ground truth and automatic segmentation that lays within the experienced human observer variance without the need of human intervention in most common cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  19. Comparison of Colour Duplex Ultrasound with Computed Tomography to Measure the Maximum Abdominal Aortic Aneurysmal Diameter

    Directory of Open Access Journals (Sweden)

    C. Gray

    2014-01-01

    Full Text Available Introduction. Maximum diameter of an abdominal aortic aneurysm (AAA is the main indication for surgery. This study compared colour duplex ultrasound (CDU and computed tomography (CT in assessing AAA diameter. Patients and Methods. Patients were included if they had both scans performed within 90 days. Pearson’s correlation coefficient, paired t-test, and limits of agreement (LOA were calculated for the whole group. Subgroup analysis of small (6.5 cm aneurysms was performed. A P value of <0.05 was considered statistically significant. Results. 389 patients were included, giving 130 pairs of tests for comparison. Excellent correlation was in the whole group (r = 0.95 and in the subgroups (r = 0.94; 0.69; 0.96, resp.. Small LOA between the two imaging modalities was found in all subgroups. Conclusion. Small aneurysms can be accurately measured using CDU. CDU is preferable for small AAAs, but cannot supplant CT for planning aortic intervention.

  20. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp. J Cardiovasc Surg (Torino) 2009;50(3):381. 14. Arthurs Z...Starnes B, See C, Andersen C. Clamp Before You Cut: Proximal Control of Ruptured Abdominal Aortic Aneurysms Using Endovascular Balloon Occlusion

  1. Challenges in the repair of large abdominal wall hernias in Nigeria: review of available options in resource limited environments.

    Science.gov (United States)

    Ezeome, E R; Nwajiobi, C E

    2010-06-01

    To evaluate the challenges and outcome of management of large abdominal wall hernias in a resource limited environment and highlight the options available to surgeons in similar conditions. A review of prospectively collected data on large abdominal wall hernias managed between 2003 and 2009. University of Nigeria Teaching Hospital, Enugu, Nigeria and surrounding hospitals. Patients with hernias more than 4 cm in their largest diameter, patients with closely sited multiple hernias or failed previous repairs and in whom the surgeon considers direct repair inappropriate. Demographics of patients with large hernias, methods of hernia repair, recurrences, early and late complications following the repair. There were 41 patients, comprising 28 females and 13 males with ages 14 - 73 years. Most (53.7%) were incisional hernias. Gynecological surgeries (66.7%) were the most common initiating surgeries. Fifteen of the patients (36.6%) have had failed previous repairs, 41.5% were obese, five patients presented with intestinal obstruction. Thirty nine of the hernias were repaired with prolene mesh, one with composite mesh and one by danning technique. Most of the patients had extra peritoneal mesh placement. Three patients needed ventilator support. After a mean follow up of 18.6 months, there was a single failed repair. Two post op deaths were related to respiratory distress. There were 12 wound infection and 8 superficial wound dehiscence, all of which except one resolved with dressing. One reoperation was done following mesh infection and extrusion. Large abdominal wall hernia repair in resource limited environments present several challenges with wound infection and respiratory distress being the most notable. Surgeons who embark on it in these environments must be prepared t o secure the proper tissue replacement materials and have adequate ventilation support.

  2. Outcomes of endovascular management of acute thoracic aortic emergencies in an academic level 1 trauma center.

    Science.gov (United States)

    Echeverria, Angela B; Branco, Bernardino C; Goshima, Kay R; Hughes, John D; Mills, Joseph L

    2014-12-01

    Thoracic aortic emergencies account for 10% of thoracic-related admissions in the United States and remain associated with high morbidity and mortality rates. Open repair has declined owing to the emergence of thoracic endovascular aortic repair (TEVAR), but data on emergency TEVAR use for acute aortic pathology remain limited. We therefore reviewed our experience. We retrospectively evaluated emergency descending thoracic aortic endovascular interventions performed at a single academic level 1 trauma center between January 2005 and August 2013 including all cases of traumatic aortic injury, ruptured descending thoracic aneurysm, penetrating atherosclerotic ulcer, aortoenteric fistula, and acute complicated type B dissection. Demographics, clinical data, and outcomes were extracted. Stepwise logistic regression was used to identify independent risk factors for death. During the study period, 51 patients underwent TEVAR; 22 cases (43.1%) were performed emergently (11 patients [50.0%] traumatic aortic injury; 4 [18.2%] ruptured descending thoracic aneurysm; 4 [18.2%] complicated type B dissection; 2 [9.1%] penetrating aortic ulcer; and 1 [4.5%] aortoenteric fistula). Overall, 72.7% (n = 16) were male with a mean age of 54.8 ± 15.9 years. Nineteen patients (86.4%) required only a single TEVAR procedure, whereas 2 (9.1%) required additional endovascular therapy, and 1 (4.5%) open thoracotomy. Four traumatic aortic injury patients required exploratory laparotomy for concomitant intra-abdominal injuries. During a mean hospital length of stay of 18.9 days (range, 1 to 76 days), 3 patients (13.6%) developed major complications. In-hospital mortality was 27.2%, consisting of 6 deaths from traumatic brain injury (1); exsanguination in the operating room before repair could be achieved (2); bowel ischemia (1) and multisystem organ failure (1); and family withdrawal of care (1). A stepwise logistic regression model identified 24-hour packed red blood cell requirements ≥4

  3. Is Decellularized Porcine Small Intestine Sub-mucosa Patch Suitable for Aortic Arch Repair?

    Science.gov (United States)

    Corno, Antonio F.; Smith, Paul; Bezuska, Laurynas; Mimic, Branko

    2018-01-01

    Introduction: We reviewed our experience with decellularized porcine small intestine sub-mucosa (DPSIS) patch, recently introduced for congenital heart defects. Materials and Methods: Between 10/2011 and 04/2016 a DPSIS patch was used in 51 patients, median age 1.1 months (5 days to 14.5 years), for aortic arch reconstruction (45/51 = 88.2%) or aortic coarctation repair (6/51 = 11.8%). All medical records were retrospectively reviewed, with primary endpoints interventional procedure (balloon dilatation) or surgery (DPSIS patch replacement) due to patch-related complications. Results: In a median follow-up time of 1.5 ± 1.1 years (0.6–2.3years) in 13/51 patients (25.5%) a re-intervention, percutaneous interventional procedure (5/51 = 9.8%) or re-operation (8/51 = 15.7%) was required because of obstruction in the correspondence of the DPSIS patch used to enlarge the aortic arch/isthmus, with median max velocity flow at Doppler interrogation of 4.0 ± 0.51 m/s. Two patients required surgery after failed interventional cardiology. The mean interval between DPSIS patch implantation and re-intervention (percutaneous procedure or re-operation) was 6 months (1–17 months). While there were 3 hospital deaths (3/51 = 5.9%) not related to the patch implantation, no early or late mortality occurred for the subsequent procedure required for DPSIS patch interventional cardiology or surgery. The median max velocity flow at Doppler interrogation through the aortic arch/isthmus for the patients who did not require interventional procedure or surgery was 1.7 ± 0.57 m/s. Conclusions: High incidence of re-interventions with DPSIS patch for aortic arch and/or coarctation forced us to use alternative materials (homografts and decellularized gluteraldehyde preserved bovine pericardial matrix). PMID:29900163

  4. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Directory of Open Access Journals (Sweden)

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  5. Hvad koster en indlaeggelse til operation for et abdominalt aortaaneurisme på et dansk sygehus?

    DEFF Research Database (Denmark)

    Vammen, Sten; Juul, Søren; Henneberg, E W

    2001-01-01

    The aim of the study was to estimate the direct cost of an abdominal aortic aneurysm (AAA) repair and to validate it against the national Diagnostic Related Group (DRG) costs.......The aim of the study was to estimate the direct cost of an abdominal aortic aneurysm (AAA) repair and to validate it against the national Diagnostic Related Group (DRG) costs....

  6. Hospitalsomkostninger ved operation for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sørensen, Jan

    2010-01-01

    The aim of the study was to estimate the direct cost of an abdominal aortic aneurysm (AAA) repair and to validate it against the national Diagnostic Related Group (DRG) costs.......The aim of the study was to estimate the direct cost of an abdominal aortic aneurysm (AAA) repair and to validate it against the national Diagnostic Related Group (DRG) costs....

  7. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  8. Satisfactory short-term outcomes of the STABILISE technique for type B aortic dissection.

    Science.gov (United States)

    Melissano, Germano; Bertoglio, Luca; Rinaldi, Enrico; Mascia, Daniele; Kahlberg, Andrea; Loschi, Diletta; De Luca, Monica; Monaco, Fabrizio; Chiesa, Roberto

    2018-03-29

    The aim of this study was to evaluate the perioperative and short-term results in a cohort of patients treated during the last year at our institution with the stent-assisted balloon-induced intimal disruption and relamination in aortic dissection repair (STABILISE) technique for acute complicated aortic dissection. Between June 2016 and June 2017, 10 patients (all male; mean age, 62.6 ± 7.4 years) received treatment for acute complicated aortic dissection with the STABILISE technique. After a standard provisional extension to induce complete attachment procedure using the commercially available endovascular dissection system (Cook Medical, Bloomington, Ind), the distal stent graft area and the bare stent area were ballooned to completely exclude the thoracic false lumen (FL) and to obtain a single-channeled abdominal aorta. Computed tomography was routinely performed within the first postoperative week before discharge and then at 3 months, at 6 months, and yearly thereafter. The technical and clinical success rates were analyzed. The 30-day technical and clinical success rates were 100%, with complete thrombosis of the thoracic FL and no type I endoleak. Malperfusion was resolved in all cases. No aortic ruptures were recorded, and no open conversion was required. One case of delayed spinal cord ischemia fully resolved within the discharge period. Predischarge computed tomography showed complete thrombosis of the thoracic FL in all cases. In two cases, some degree of patency of the abdominal FL was observed. At short-term follow-up, the overall aortic diameters remained stable with no further dilation. The STABILISE technique was safe and feasible in this cohort of patients, with complete thrombosis of the thoracic FL and creation of a single-channeled aorta in most cases. Further studies are needed to ascertain the long-term behavior of the treated aorta. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Abdominal Wall Reconstruction with Concomitant Ostomy-Associated Hernia Repair: Outcomes and Propensity Score Analysis.

    Science.gov (United States)

    Mericli, Alexander F; Garvey, Patrick B; Giordano, Salvatore; Liu, Jun; Baumann, Donald P; Butler, Charles E

    2017-03-01

    The optimal strategy for abdominal wall reconstruction in the presence of a stomal-site hernia is unclear. We hypothesized that the rate of ventral hernia recurrence in patients undergoing a combined ventral hernia repair and stomal-site herniorraphy would not differ clinically from the ventral hernia recurrence rate in patients undergoing an isolated ventral hernia repair. We also hypothesized that bridged ventral hernia repairs result in worse outcomes compared with reinforced repairs, regardless of stomal hernia. We retrospectively reviewed prospectively collected data from consecutive abdominal wall reconstructions performed with acellular dermal matrix (ADM) at a single center between 2000 and 2015. We compared patients who underwent a ventral hernia repair alone (AWR) and those who underwent both a ventral hernia repair and ostomy-associated herniorraphy (AWR+O). We conducted a propensity score matched analysis to compare the outcomes between the 2 groups. Multivariable Cox proportional hazards and logistic regression models were used to study associations between potential predictive or protective reconstructive strategies and surgical outcomes. We included 499 patients (median follow-up 27.2 months; interquartile range [IQR] 12.4 to 46.6 months), 118 AWR+O and 381 AWR. After propensity score matching, 91 pairs were obtained. Ventral hernia recurrence was not statistically associated with ostomy-associated herniorraphy (adjusted hazard ratio [HR] 0.7; 95% CI 0.3 to 1.5; p = 0.34). However, the AWR+O group experienced a significantly higher percentage of surgical site occurrences (34.1%) than the AWR group (18.7%; adjusted odds ratio 2.3; 95% CI 1.4 to 3.7; p < 0.001). In the AWR group, there were significantly fewer ventral hernia recurrences when the repair was reinforced compared with bridged (5.3% vs 38.5%; p < 0.001). There was no statistically significant difference in ventral hernia recurrence between the AWR and AWR+O groups. Bridging was associated

  10. Volumetric analysis demonstrates that true and false lumen remodeling persists for 12 months after thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Ga-Young Suh, PhD

    2016-09-01

    Full Text Available A 62-year-old man underwent an elephant trunk procedure followed by thoracic endovascular aortic repair (TEVAR. Computed tomography angiography-based models were built to quantify volume of the whole aorta and true and false lumens preoperatively, before TEVAR, after TEVAR, and at follow-up at 3, 6, and 12 months. With TEVAR, descending aortic true lumen volume increased by 54%, then increased additionally by 60% during 12 months. The descending aortic false lumen volume regressed continuously for 12 months following TEVAR, with the most rapid rate from 6 to 12 months at 16 cm3/month. TEVAR immediately increased true lumen volume and continued to remodel the true and false lumens throughout the following 12 months.

  11. Tamoxifen up-regulates catalase production, inhibits vessel wall neutrophil infiltration, and attenuates development of experimental abdominal aortic aneurysms.

    Science.gov (United States)

    Grigoryants, Vladimir; Hannawa, Kevin K; Pearce, Charles G; Sinha, Indranil; Roelofs, Karen J; Ailawadi, Gorav; Deatrick, Kristopher B; Woodrum, Derek T; Cho, Brenda S; Henke, Peter K; Stanley, James C; Eagleton, Matthew J; Upchurch, Gilbert R

    2005-01-01

    Selective estrogen receptor modulators (SERMs), similar to estrogens, possess vasoprotective effects by reducing release of reactive oxygen species. Little is known about the potential effects of SERMs on the pathogenesis of abdominal aortic aneurysms (AAAs). This study's objective was to investigate the growth of experimental AAAs in the setting of the SERM tamoxifen. In the first set of experiments, adult male rats underwent subcutaneous tamoxifen pellet (delivering 10 mg/kg/day) implantation (n = 14) or sham operation (n = 16). Seven days later, all animals underwent pancreatic elastase perfusion of the abdominal aorta. Aortic diameters were determined at that time, and aortas were harvested 7 and 14 days after elastase perfusion for immunohistochemistry, real-time polymerase chain reaction, Western blot analysis, and zymography. In the second set of experiments, a direct irreversible catalase inhibitor, 3-amino-1,2,4-triazole (AT), was administered intraperitoneally (1 mg/kg) daily to tamoxifen-treated (n = 6) and control rats (n = 6), starting on day 7 after elastase perfusion. Aortic diameters were measured on day 14. In a third set of experiments, rats were perfused with catalase (150 mg/kg) after the elastase (n = 5), followed by daily intravenous injections of catalase (150 mg/kg/day) administered for 10 days. A control group of rats (n = 7) received 0.9% NaCl instead of catalase. Mean AAA diameters were approximately 50% smaller in tamoxifen-treated rats compared with sham rats 14 days after elastase perfusion (P = .002). The tamoxifen-treated group's aortas had a five-fold increase in catalase mRNA expression (P = .02) on day 7 and an eight-fold increase in catalase protein on day 14 (P = .04). Matrix metalloprotroteinase-9 activity was 2.4-fold higher (P = .01) on day 7 in the aortas of the controls compared to the tamoxifen-treated group's aortas. Tamoxifen-treated rats had approximately 40% fewer aortic polymorphonuclear neutrophils compared to

  12. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  13. Endovascular Repair of Aortic Dissection in Marfan Syndrome: Current Status and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Rosario Parisi

    2015-07-01

    Full Text Available Over the last decades, improvement of medical and surgical therapy has increased life expectancy in Marfan patients. Consequently, the number of such patients requiring secondary interventions on the descending thoracic aorta due to new or residual dissections, and distal aneurysm formation has substantially enlarged. Surgical and endovascular procedures represent two valuable options of treatment, both associated with advantages and drawbacks. The aim of the present manuscript was to review endovascular outcomes in Marfan syndrome and to assess the potential role of Thoracic Endovascular Aortic Repair (TEVAR in this subset of patients.

  14. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  15. Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.

    Science.gov (United States)

    Shahverdyan, Robert; Mylonas, Spyridon; Gawenda, Michael; Brunkwall, Jan

    2018-04-01

    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients

  16. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  17. Does Lower Limb Exercise Worsen Renal Artery Hemodynamics in Patients with Abdominal Aortic Aneurysm?

    OpenAIRE

    Sun, Anqiang; Tian, Xiaopeng; Zhang, Nan; Xu, Zaipin; Deng, Xiaoyan; Liu, Ming; Liu, Xiao

    2015-01-01

    Renal artery stenosis (RAS) and renal complications emerge in some patients after endovascular aneurysm repair (EVAR) to treat abdominal aorta aneurysm (AAA). The mechanisms for the causes of these problems are not clear. We hypothesized that for EVAR patients, lower limb exercise could negatively influence the physiology of the renal artery and the renal function, by decreasing the blood flow velocity and changing the hemodynamics in the renal arteries. To evaluate this hypothesis, pre- and ...

  18. The role of prophylactic cefazolin in the prevention of infection after various types of abdominal wall hernia repair with mesh

    Directory of Open Access Journals (Sweden)

    Mostafa Mehrabi Bahar

    2015-07-01

    Conclusion: Preoperative administration of single-dose cefazolin for prosthetic hernia repairs did not markedly decrease the risk of wound infection. Our results do not support the use of cefazolin as a prophylactic antibiotic for various kinds of abdominal wall hernia repair with mesh.

  19. Repair of Postoperative Abdominal Hernia in a Child with Congenital Omphalocele Using Porcine Dermal Matrix

    Directory of Open Access Journals (Sweden)

    V. Lambropoulos

    2016-01-01

    Full Text Available Introduction. Incisional hernias are a common complication appearing after abdominal wall defects reconstruction, with omphalocele and gastroschisis being the most common etiologies in children. Abdominal closure of these defects represents a real challenge for pediatric surgeons with many surgical techniques and various prosthetic materials being used for this purpose. Case Report. We present a case of repair of a postoperative ventral hernia occurring after congenital omphalocele reconstruction in a three-and-a-half-year-old child using an acellular, sterile, porcine dermal mesh. Conclusion. Non-cross-linked acellular porcine dermal matrix is an appropriate mesh used for the reconstruction of abdominal wall defects and their postoperative complications like large ventral hernias with success and preventing their recurrence.

  20. Background differences in baseline and stimulated MMP levels influence abdominal aortic aneurysm susceptibility

    Science.gov (United States)

    Dale, Matthew A.; Ruhlman, Melissa K.; Zhao, Shijia; Meisinger, Trevor; Gu, Linxia; Swier, Vicki J.; Agrawal, Devendra K.; Greiner, Timothy C.; Carson, Jeffrey S.; Baxter, B. Timothy; Xiong, Wanfen

    2015-01-01

    Objective Evidence has demonstrated profound influence of genetic background on cardiovascular phenotypes. Murine models in Marfan syndrome (MFS) have shown that genetic background-related variations affect thoracic aortic aneurysm formation, rupture, and lifespan of mice. MFS mice with C57Bl/6 genetic background are less susceptible to aneurysm formation compared to the 129/SvEv genetic background. In this study, we hypothesize that susceptibility to abdominal aortic aneurysm (AAA) will be increased in 129/SvEv mice versus C57Bl/6 mice. We tested this hypothesis by assessing differences in aneurysm size, tissue properties, immune response, and MMP expression. Methods Mice of C57Bl/6 or 129/SvEv background underwent AAA induction by periaortic application of CaCl2. Baseline aortic diameters, tissue properties and MMP levels were measured. After aneurysm induction, diameters, MMP expression, and immune response (macrophage infiltration and bone marrow transplantation) were measured. Results Aneurysms were larger in 129/SvEv mice than C57Bl/6 mice (83.0% ± 13.6 increase compared to 57.8% ± 6.4). The aorta was stiffer in the 129/SvEv mice compared to C57Bl/6 mice (952.5 kPa ± 93.6 versus 621.4 kPa ± 84.2). Baseline MMP-2 and post-aneurysm MMP-2 and -9 levels were higher in 129/SvEv aortas compared to C57Bl/6 aortas. Elastic lamella disruption/fragmentation and macrophage infiltration were increased in 129/SvEv mice. Myelogenous cell reversal by bone marrow transplantation did not affect aneurysm size. Conclusions These data demonstrate that 129/SvEv mice are more susceptible to AAA compared to C57Bl/6 mice. Intrinsic properties of the aorta between the two strains of mice, including baseline expression of MMP-2, influence susceptibility to AAA. PMID:26546710