WorldWideScience

Sample records for 64-row multidetector computed

  1. 64-row multidetector computed tomography portal venography of gastric variceal collateral circulation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM:To study characteristics of collateral circulation of gastric varices (GVs) with 64-row multidetector computer tomography portal venography (MDCTPV).METHODS:64-row MDCTPV with a slice thickness of 0.625 mm and a scanning field from 2 cm above the tracheal bifurcation to the lower edge of the kidney was performed in 86 patients with GVS diagnosed by endoscopy. The computed tomography protocol included unenhanced,arterial and portal vein phases. The MDCTPV was performed on an AW4.3 workstation. GVs were c...

  2. Characteristics of paraesophageal varices: A study with 64-row multidetector computed tomograghy portal venography

    Institute of Scientific and Technical Information of China (English)

    Li-Qin Zhao; Wen He; Guang Chen

    2008-01-01

    AIM:To identify the charactedsUcs of morphology,location and collateral circulation involved in paraesophageal varices (para-EV) of portal hypertension patients with 64-row multidetector computed tomograghy (MDCT).METHODS:Fifty-two of 501 patients with portal hypertensive cirrhosis accompanied with esophageal varices were selected for 64-row MDCT examination after the observation of para-EV.The CT protocol included unenhanced,arterial and portal phases with a slice thickness of 0.625 mm and a scanning field of 2 cm above the bifurcation to the lower edge of kidney.The CT portal venography (CTPV) was reformatted on AW4.3 workstation.The characteristics of origination,location,morphology and collateral circulation in para-EV were observed.RESULTS:Among the 52 cases of para-EV,50 showed the originations from the posterior branch of left gastric vein,while the others from the anterior branch.Fifty cases demonstrated their locations close to the esophagealgastric junction,and the other two cases were extended to the inferior bifurcation of the trachea.The circuitous pattern was observed in 16 cases,while reticulated pattern was seen in 36 cases.Collateral circulation identified 4 cases of single periesophageal varices (peri-EV) communication,3 cases of single hemiazygous vein,one case of single inferior vena cava,41 cases of mixed type (collateral communications of at least 2 of above mentioned types) and 3 cases of undetermined communications.Among all the cases,43 patients showed the communications between para-EV and peri-EV,while hemiazygous vein (43 cases) and inferior vena cava (5 cases) were also involved.CONCLUSION:Sixty-four-row multidetector computed tomograghy portal venography could display the location,morphology,origin,and collateral types of paraEV,which provides important and referable information for clinical management and disease prognosis.

  3. Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Chee Khoon LIEW; Kui Hian SIM; Rapaee ANNUAR; Tiong Kiam ONG; Sze Piaw CHIN; Tobias Seyfarth; Yean Yip FONG; Wei Ling CHAN; Choon Kiat ANG; Houng Bang LIEW

    2006-01-01

    Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF.

  4. Whole tumour quantitative measurement of first-pass perfusion of oesophageal squamous cell carcinoma using 64-row multidetector computed tomography: Correlation with microvessel density

    Energy Technology Data Exchange (ETDEWEB)

    Chen Tianwu, E-mail: twchenscu@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Sichuan Province Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637007 (China); Yang Zhigang, E-mail: yangzg6666@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Wang Qiling, E-mail: xiaohongmao99@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li Yuan, E-mail: dr.liyuan@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Qian Lingling, E-mail: moneylinglingch1999@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Chen Huijiao, E-mail: joan-ch@sohu.com [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2011-08-15

    Purpose: To assess correlations between whole tumour first-pass perfusion parameters obtained with 64-row multidetector computed tomography (MDCT), and microvessel density (MVD) in oesophageal squamous cell carcinoma. Materials and Methods: Thirty-one consecutive patients with surgically confirmed oesophageal squamous cell carcinomas were enrolled into our study. All the patients underwent whole tumour first-pass perfusion scan with 64-row MDCT. Perfusion parameters, including perfusion (PF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Postoperative tumour specimens were assessed for MVD. Pearson correlation coefficient tests were performed to determine correlations between each perfusion parameter and MVD. Results: Mean values for PF, PED, BV and TTP of the whole tumour were 28.85 {+-} 20.29 ml/min/ml, 23.16 {+-} 8.09 HU, 12.13 {+-} 5.21 ml/100 g, and 35.05 {+-} 13.85 s, respectively. Mean MVD in whole tumour at magnification (x200) was 15.75 {+-} 4.34 microvessel/tumour sample (vessels/0.723 mm{sup 2}). PED and BV were correlated with MVD (r = 0.651 and r = 0.977, respectively, all p < 0.05). However, PF and TTP were not correlated with MVD (r = 0.070 and r = 0.100, respectively, all p > 0.05). Conclusion: The BV value of first-pass perfusion CT could reflect MVD in oesophageal squamous cell carcinoma, and can be an indicator for evaluating the tumour angiogenesis.

  5. 64-row multi-dector computed tomography coronary image from a center with early experience: first illustration of learning curve

    Institute of Scientific and Technical Information of China (English)

    Sze Piaw CHIN; Tiong Kiam ONG; Wei Ling CHAN; Chee Khoon LIEW; M.Tobias Seyfarth; Fong Yean Yip ALAN; Houng Bang LIEW; Kui Hian SIM

    2006-01-01

    Background and objectives The recent joint ACCF/AHA clinical competence statement on cardiac imaging with multi-detector computed tomography recommended a minimum of 6 months training and 300 contrast examinations, of which the candidate must be directly involved in at least 100 studies. Whether this is adequate to become proficient in interpretation of coronary computed tomogsignificant coronary stenosis in a center with 1 year's experience using a 64-row scanner. Methods A total of 778 patients underwent contrast-enhanced CTA between January and December 2005. Out of these patients, 301 patients also underwent contrast-enhanced conventional coronary angiography (CCA). These patients were divided into 4 groups according to the time the examination was underwent. Group Q1: first quarter of the year (n=20), Group Q2: second quarter (n=128), Group Q3: third quarter (n=134), and Group Results The sensitivity, specificity, positive, and negative predictive values were Q1 - 64%, 89%, 49% and 94%, respectively; Q2 -79%, 96%, 74% and 97%, respectively; Q3 - 78%, 96%, 74%, 97%, respectively, and Q4 - 100% for all. Conclusions In a center with formal training and high caseload, our accuracy in CTA analysis reached a plateau after 6 months experience. Test-bolus protocols produce better image quality and can improve accuracy. New centers embarking on CTA will need to overcome an initial 6-month learning curve depending upon the caseload during which time they should consider correlation with CCA.

  6. Comparison of 64-row and 16-row multidetector CT in the perfusion CT evaluation of acute ischemic stroke patients receiving intravenous thrombolytic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sillanpaa, Niko; Dastidar, Prasun; Soimakallio, Seppo [Tampere University Hospital, Medical Imaging Centre, PL 2000, Tampere (Finland); Rusanen, Harri [Oulu University Hospital, Department of Neurology, Oulu (Finland); Saarinen, Jukka T. [Tampere University Hospital, Department of Neurology, Tampere (Finland)

    2012-09-15

    Perfusion computed tomography (PCT) is increasingly performed in multimodal CT evaluation of acute ischemic stroke. We compared the technical quality of perfusion studies performed with a 16-row and a 64-row scanner and analyzed the differences between the scanners in their ability to detect perfusion defects. We analyzed retrospectively the clinical and imaging data of 140 consecutive acute (<3 h) stroke patients who underwent multimodal CT evaluation and received intravenous rtPA. Alberta Stroke Program Early CT Score (ASPECTS) was assigned to PCT maps. Clinical and imaging parameters were compared between the two scanners. There were more motion artifacts in the 16-row studies (p = 0.04), and the analysis software was able to completely correct significantly fewer of these (p < 0.001). Both ASPECTS levels were optimally covered in only 29% of the 16-row studies, whereas in the 64-row studies, both levels were invariably optimally visualized (p < 0.001). This significantly decreased the sensitivity of the 16-row scanner to detect perfusion defects in the upper ASPECTS level (p = 0.02). The 64-row scanner was able to detect more perfusion defects that were located entirely outside the ASPECTS regions (p = 0.03). There was no significant difference in the 3-month functional outcome. The 16-row scanner suffered from limited anatomic coverage that decreased the sensitivity to detect perfusion defects in the cranial parts of the middle cerebral artery region. The 16-row studies had poorer technical quality that was in part attributable to higher sampling frequency and smaller slice thickness making the imaging more sensitive to small-scale movement of the patient. (orig.)

  7. Vascular air embolism after contrast administration on 64 row multiple detector computed tomography: A prospective analysis

    Directory of Open Access Journals (Sweden)

    Kushaljit S Sodhi

    2015-01-01

    Full Text Available Background: Vascular air embolism is being progressively reported as a nonfatal event with increase in use of computed tomography (CT as a diagnostic modality. This study was undertaken to study the frequency and site of vascular air embolism in patients undergoing contrast-enhanced CT (CECT and analyze CT parameters that influence its prevalence and final outcome. Materials and Methods: This was a prospective study approved by departmental ethics committee. Presence and location of air emboli in 200 patients who underwent CT scan of chest on a 64 detector scanner was recorded. We analyzed the role of various factors that could influence the prevalence of air embolism after injection of contrast in CECT scans. These factors included the amount of contrast injected, rate of flow of injection of contrast, site of injection of contrast, and size of intravenous access line. Results: Iatrogenic vascular air emboli were seen in 14 patients (7% of total. The locations of air emboli were main pulmonary artery in 12 (6% of total, left brachiocephalic vein in 3 (1.5% of total, right atrial appendage in 4 (2% of total, and superior vena cava (SVC in 1 (0.5% patient. There was no association between volume of contrast, flow rate, site and size of intravenous access, and presence of air emboli. Conclusion: Radiologists as well as referring physicians should be aware of vascular air embolism, which can occur after contrast injection in patients undergoing CT scan. Age, volume of contrast, flow rate of pressure injector, and site and size of venous cannula do not influence the likelihood or incidence of detection of venous air emboli on CT scans.

  8. The added diagnostic value of 64-row multidetector CT combined with contrast-enhanced US in the evaluation of hepatocellular nodule vascularity: implications in the diagnosis of malignancy in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    The aim of this study was to assess the added diagnostic value of contrast-enhanced US (CEUS) combined with 64-row multidetector CT (CT) in the assessment of hepatocellular nodule vascularity in patients with liver cirrhosis. One hundred and six cirrhotic patients (68 male, 38 female; mean age ± SD, 70 ± 7 years) with 121 biopsy-proven hepatocellular nodules (72 hepatocellular carcinomas, 10 dysplastic and 15 regenerative nodules, 12 hemangiomas, and 12 other benignancies) detected during US surveillance were prospectively recruited. Each nodule was scanned by CEUS during the arterial (10-40 s), portal venous (45-90 s), and delayed sinusoidal phase (from 100 s after microbubble injection to microbubble disappearance). Nodule vascularity at CEUS, CT, and combined CEUS/CT was evaluated side-by-side by two independent blinded readers who classified nodules as benign or malignant according to reference diagnostic criteria. The combined assessment of CEUS/CT provided higher sensitivity (97%, both readers) than did separate assessment of CEUS (88% reader 1; 87% reader 2) and CT (74% reader 1; 71% reader 2; P < 0.05), while no change in specificity was provided by combined analysis. The combined assessment of hepatocellular nodule vascularity at CT and CEUS improved sensitivity in the diagnosis of malignancy in patients with liver cirrhosis. (orig.)

  9. Interatrial shunt. Diagnosis of patent foramen ovale and atrial septal defect with 64-row coronary computed tomography angiography

    International Nuclear Information System (INIS)

    The aim of this study was to investigate the frequency with which interatrial shunts are found during routine coronary computed tomography (CT) angiography and to describe imaging characterizations of patent foramen ovale (PFO), atrial septal defect (ASD), and atrial septal aneurysm (ASA). A total of 1081 adult patients were evaluated retrospectively for interatrial shunting; 77 were excluded from the study. CT diagnosis of PFO was defined as (1) a channel-like appearance of the interatrial septum (IAS) and (2) a contrast agent jet flow from the left atrium (LA) to the right atrium (RA). ASD was defined as (1) the IAS resembling a membrane with a hole and (2) a contrast jet flow between the two atria. ASA was identified by detecting a minimum 10-mm protrusion of the LA beyond the IAS into the RA. Among 1004 patients, 86 patients (8.6%) were diagnosed to have PFO. Another 23 patients (2.3%) had a hole in the IAS and were diagnosed as having ASD: 21 with an ostium secundum-type ASD and 2 with the sinus venosus type. ASA accompanied ASD in three patients. Electrocardiography-gated CT using the saline-chaser contrast injection technique that is routinely used for coronary arterial imaging can be used to detect interatrial shunts. The technique can also serve as a method for differentiating PFO, ASD, and ASA. (author)

  10. Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

    Science.gov (United States)

    Pan, Zilai; Pang, Lifang; Li, Jianying; Zhang, Huan; Yang, Wenjie; Ding, Bei; Chai, Weimin; Chen, Kemin; Yao, Weiwu

    2011-04-01

    To evaluate the clinical value of a body mass index (BMI) based tube current (mA) selection method for obtaining consistent image quality with dose optimization in MDCT prospective ECG gated coronary calcium scoring. A formula for selecting mA to achieve desired image quality based on patient BMI was established using a control group (A) of 200 MDCT cardiac patients with a standard scan protocol. One hundred patients in Group B were scanned with this BMI-dependent mA for achieving a desired noise level of 18 HU at 2.5 mm slice thickness. The CTDIvol and image noise on the ascending aorta for the two groups were recorded. Two experienced radiologists quantitatively evaluated the image quality using scores of 1-4 with 4 being the highest. The image quality scores had no statistical difference (P = 0.71) at 3.89 ± 0.32, 3.87 ± 0.34, respectively, for groups A and B of similar BMI. The image noise in Group A had linear relationship with BMI. The image noise in Group B using BMI-dependent mA was independent of BMI with average value of 17.9 HU and smaller deviations for the noise values than in Group A (2.0 vs. 2.9 HU). There was a 35% dose reduction with BMI-dependent mA selection method on average with the lowest effective dose being only 0.35 mSv for patient with BMI of 18.3. A quantitative BMI-based mA selection method in MDCT prospective ECG gated coronary calcium scoring has been proposed to obtain a desired and consistent image quality and provide dose optimization across patient population.

  11. Correlation between US-PSV and 64-Row MDCTA with Advanced Vessel Analysis in the Quantification of 50–70% Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Matteo Stefanini

    2012-01-01

    Full Text Available Purpose. To correlate ultrasonographic peak systolic velocity (US-PSV and 64-row multidetector computed tomography angiography (MDCTA with advanced vessel analysis (AVA software in the quantification of 50–70% carotid artery stenosis. Materials and methods. 199 consecutive patients (247 arteries with internal carotid artery (ICA or third proximal bifurcation stenosis. Each patient was studied by duplex US (DUS and 64-row MDCTA with AVA software. Results. DUS showed PSV measurements less than 125 cm/s in 51 carotid stenosis and a value greater than this in 196 arteries. 64-row MDCTA AVA software showed a grade of stenosis less than 50% in 42 carotid arteries while a greater 70% was found in 4 carotid arteries; then, carotid arteries with stenosis percentage between 50% and 70% were 201. Linear regression analysis showed a good linear correlation (=0.88 between MDCTA-AVA software percentage stenosis and PSV: between 50% grade of stenosis and PSV value corresponding to 133,6 cm/sec and between 70% stenosis and PSV value corresponding to 268 cm/sec. The sensitivity, specificity, positive predictive value(PPV, negative predictive value(NPV of this analysis were 93%, 82%, 97%, 75%, respectively. Conclusion. Linear correlation between PSV data and grade of stenosis from 50% to 70% obtained with 64-row MDCTA AVA software. Main PSV value corresponding to 50% and 70% grade of stenosis at AVA analysis.

  12. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Blood Pressure Tools & Resources Stroke More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 3,2015 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  13. Imaging findings of myocardial revascularization at multidetector computed tomography: where are the bypass grafts?: an iconographic essay

    International Nuclear Information System (INIS)

    Multidetector coronary computed tomography angiography is a precise method for evaluating post-coronary revascularization arterial and venous bypass grafts, and is somehow superseding coronary catheterization that is an invasive and more expensive technique. The present iconographic essay is aimed at anatomically demonstrating the bypass grafts most frequently utilized, how to differentiate between arterial and venous grafts and how to find them. The studies were performed in 64-row multidetector computed tomography equipment, with breath hold, controlled heart rate and appropriate protocols with later MPR, MIP and 3D reconstructions according to electrocardiogram. The localization of the bypass grafts and anastomoses at computed tomography studies focused on chest and coronary arteries may represent a difficulty in the images analysis by the radiologist who is not familiar with the matter, so the knowledge of the surgical techniques adopted and possible courses of the saphenous bypass grafts and arterial grafts can aid in the analysis of both studies, avoiding diagnostic errors. (author)

  14. Application of MPVR and TL-VR with 64-row MDCT in neonates with congenital EA and distal TEF

    Institute of Scientific and Technical Information of China (English)

    Yang Wen; Yun Peng; Ren-You Zhai; Ying-Zi Li

    2011-01-01

    AIM: To assess the application of multiple planar volume reconstruction (MPVR) and three-dimensional (3D) transparency lung volume rendering (TL-VR) with 64-row multidetector-row computed tomography (MDCT) in neonates with congenital esophageal atresia (EA) and distal tracheoesophageal fistula (TEF). METHODS: Twenty neonates (17 boys, 3 girls) with EA and distal TEF at a mean age of 4.6 d (range 1-16 d) were enrolled in this study. A helical scan of 64-row MDCT was performed at the 64 mm × 0.625 mm collimation. EA and TEF were reconstructed with MPVR and TL-VR, respectively. Initial diagnosis of EA was made by chest radiography showing the inserted catheter in the proximal blind-ended esophageal pouch. Manifestations of MDCT images were compared with the findings at surgery. RESULTS: MDCT showed the proximal and distal esophageal pouches in 20 cases. No significant difference was observed in gaps between the proximal and distal esophageal pouches detected by MPVR and TLVR. The lengths of gaps between the proximal and distal esophageal pouches detected by MPVR and TL-VR correlated well with the findings at surgery (R = 0.87, P < 0.001). The images of MPVR revealed the orifice of TEF in 13 cases, while TL-VR images showed the orifice of TEF in 4 cases. CONCLUSION: EA and distal TEF can be reconstructed using MPVR and TL-VR of 64-row MDCT, which is a noninvasive technique to demonstrate the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  15. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Chandrashekhar, Guruprasadh, E-mail: cguruprasadh@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Sodhi, Kushaljit Singh, E-mail: sodhiks@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Saxena, Akshay Kumar, E-mail: fatakshay@yahoo.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Rohit, Manoj Kumar, E-mail: rohitmanoj@gmail.com [Department of Pediatric Cardiology, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India)

    2012-12-15

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  16. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    International Nuclear Information System (INIS)

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  17. HORSESHOE KIDNEY: A MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2015-06-01

    Full Text Available Background and Objective: Horseshoe kidney is the most common renal fusion anomaly with a reported prevalence of 1 in 400 persons with a male to female ratio of 2:1. In many cases its presence may go unnoticed and undiagnosed because the patient may remain asymptomatic throughout life. The objective of our study is to report radiological and anatomical features of horseshoe kidney detected incidentally during retrospective evaluation of multidetector computed tomography scans. Materials and Methods: Contrast enhanced multidetector computed tomography scans of 682 patients, 355 males and 327 females, were reviewed retrospectively. Results: Seven cases of horseshoe kidney were detected incidentally, six males and one female, with an incidence of 1.02 %. In all cases, malrotation of the kidneys were observed with the hilum facing anteriorly or anterolaterally. The isthmus was made up of parenchymal tissue in all the cases and the fusion was midline in four cases and lateral in three cases. Horseshoe kidney in all cases was supplied by multiple renal arteries, varying from 3 to 6. In three cases symmetrical arterial supply and in the rest asymmetrical supply was observed. Nephrolithiasis and hydronephrosis were noted in two patients. No other associated congenital anomaly was observed in all seven patients. Conclusion: Contrast enhanced multidetector computed tomography evaluation of patients with horseshoe kidney provide excellent information about its vascularity, collecting system and other associated conditions.

  18. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina)], E-mail: patriciacarrascosa@diagnosticomaipu.com.ar; Baronio, Mariano [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina); Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina); Borghi, Mario; Sueldo, Carlos; Papier, Sergio [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina)

    2008-09-15

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 {+-} 3 min, whereas for HSG was 28 {+-} 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results.

  19. Multidetector Computed Tomography in Acute Joint Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Haapamaeki, V.V.; Kiuru, M.J.; Mustonen, A.O.; Koskinen, S.K. [Helsinki Univ. Central Hospital (Finland). Helsinki Medical Imaging Center

    2005-10-01

    Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventional single-slice spiral CT. MDCT with multiplanar reformation is helpful in disclosing fracture patterns, particularly in complex joint fractures, where they reveal occult fractures and show the exact number of fracture components and their degree of displacement.

  20. ECG-Edit function in multidetector-row computed tomography coronary arteriography for patients with arrhythmias

    International Nuclear Information System (INIS)

    Electrocardiogram (ECG)-gating is necessary for cardiac computed tomography, but is not suitable for arrhythmias, so the aim of this study was to evaluate the usefulness of the ECG-edit function for this purpose. Of 1,221 patients undergoing 64-row multidetector-row computed tomography coronary angiography (coronary MDCT), 123 patients (28 atrial fibrillation (Af), 39 premature atrial contractions (PAC), 42 premature ventricular contractions (PVC), 3 PAC+PVC, 10 sinus arrhythmias (SA), and a second-degree atrioventricular block (2deg AVB)) had arrhythmias necessitating the ECG-edit function. Short R-R interval was deleted and mid-diastolic phases were selected from the long R-R intervals using the ''R+absolute time'' method. In the present study, the reconstructed images were evaluated using a triple-grade scale A-C, representing excellent, acceptable, and unacceptable image quality. Image quality, categorized as A, B and C, respectively, was 50%, 36% and 14% for the 28 patients with Af; 56%, 36% and 8% for the 39 PAC patients, and 65%, 33% and 2% in the 42 PVC patients. None of the scans of the PAC+PVC, SA, and 2deg AVB patients was ranked as C. The ECG-edit function is useful for reconstructing coronary MDCT images in many arrhythmias, and provides clinically acceptable images in most cases. (author)

  1. Myocardial perfusion with multi-detector computed tomography: quantitative evaluation

    International Nuclear Information System (INIS)

    The objective of this work is to evaluate the skill of multidetector computer tomography, to quantify the different patterns of intensification during the evaluation of the myocardial perfusion. 45 patients were studied with suspicion of cardiovascular disease. Multi-detector computed tomography was utilized on patients at rest and in effort with pharmacological stress, after the administration of dipyridamole. Also they were evaluated using nuclear medicine

  2. Detection of Postcoronary Stent Complication: Utility of 64-Slice Multidetector CT

    Directory of Open Access Journals (Sweden)

    Alpa Bharati

    2012-01-01

    Full Text Available Coronary stent fracture is a known complication of coronary arterial stent placements. Multiple long-term risks are also associated with drug eluting stents. 64-slice multidetector CT (MDCT coronary angiography has been shown to detect poststent complications such as instent stenosis, thrombosis, stent migration and stent fractures. We report a case of stent fracture in a patient who underwent RCA stenting with associated RCA perforation and almost complete thrombosis of the RCA and peristent fibrinoid collection. This is a rare case of stent fracture with perforation of the RCA. The paper highlights the role of 64-row multidetector computed tomography (MDCT in evaluation of such poststent placement complications.

  3. Multidetector computed tomography of jaw lesions in children and adolescents

    International Nuclear Information System (INIS)

    Full text: Jaw lesions in paediatric and adolescent population are uncommon and can arise in odontogenic or non-odontogenic tissues. With the advent of multidetector computed tomography (MDCT), algorithm for imaging jaw lesions has changed dramatically. This pictorial essay describes the imaging appearance of commonly encountered jaw lesions in children and adolescents with emphasis on MDCT findings

  4. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  5. Noninvasive coronary angioscopy using electron beam computed tomography and multidetector computed tomography

    NARCIS (Netherlands)

    van Ooijen, PMA; Nieman, K; de Feyter, PJ; Oudkerk, M

    2002-01-01

    With the advent of noninvasive coronary imaging techniques like multidetector computed tomography and electron beam computed tomography, new representation methods such as intracoronary visualization. have been introduced. We explore the possibilities of these novel visualization techniques and comp

  6. Multidetector computed tomography of the coronary arteries - pictorial essay

    International Nuclear Information System (INIS)

    Multidetector computed tomography (MDCT) is being used more frequently for the detection of atherosclerotic coronary artery disease (CAD). MDCT allows for very rapid image acquisition with little motion artifact, resulting in the ability to quantitate calcified atherosclerotic plaque. Congenital coronary artery anomalies are readily identified using this technique. A key advantage is the noninvasiveness of the study, with no intravascular contrast media needed. Knowledge of coronary artery anatomy as well as of the potential pitfalls is required. (author)

  7. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  8. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  9. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    International Nuclear Information System (INIS)

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  10. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  11. Pulmonary involvement in ankylosing spondylitis assessed by multidetector computed tomography

    International Nuclear Information System (INIS)

    Ankylosing spondylitis (AS) may present with extra-articular involvement in the lungs. We aimed to evaluate the abnormal pulmonary multidetector computed tomography findings of patients with AS and compare them with the clinical symptoms, duration of illness, laboratory results and pulmonary function tests (PFT). We evaluated the chest multidetector computed tomography (MDCT) findings of 41 patients with ankylosing spondylitis (AS) and compared them with pulmonary function test (PFT) results, demographic characteristics, duration of illness and laboratory findings that we were able to obtain. The most common abnormalities were nodules, peribronchial thickening, pleural thickening and bronchiectasis. Abnormalities occurred in 96.87% of patients in the early AS group and 77.8% of patients in the late AS group. Patients with early AS included asymptomatic individuals with normal PFT results and abnormal MDCT findings. The use of MDCT in AS patients may be beneficial for the evaluation of pulmonary disease, even in asymptomatic patients without any PFT abnormalities and those in the early stages of the disease

  12. CROSSED FUSED RENAL ECTOPIA MULTIDETECTOR COMPUTED TOMOGRAPHY STUDY

    Directory of Open Access Journals (Sweden)

    Sharma V

    2014-06-01

    Full Text Available Crossed renal ectopia is one of the rarest congenital malformations where a kidney is located on the side opposite to the side of its ureteral insertion into the urinary bladder and is generally fused with the normally located ipsilateral mate. Generally this anomaly remains as a silent clinical entity and is incidentally detected during evaluation for other conditions. We report here three such cases of crossed fused renal ectopia detected by multidetector row contrast enhanced computed tomography. Crossed fused renal ectopia of inferior type was observed in a male on the right side with the ureter of the ectopic left kidney crossing the midline. In two female patients, L-shaped or tandem kidney was noted, one on the right and another on the left side. Over all in two cases the left kidney was ectopic and in one the right kidney. No renal pathologies like urinary tract infection, nephrolithiasis or hematuria were found in our patients.

  13. 64-row MDCT perfusion of head and neck squamous cell carcinoma: technical feasibility and quantitative analysis of perfusion parameters

    Energy Technology Data Exchange (ETDEWEB)

    Faggioni, Lorenzo; Neri, Emanuele; Cerri, Francesca; Picano, Eugenia; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Pisa (Italy); Seccia, Veronica; Muscatello, Luca; Franceschini, Stefano Sellari [University of Pisa, Division of Otorhinolaryngology, Pisa (Italy)

    2011-01-15

    To evaluate the technical feasibility of 64-row computed tomography (CT) quantitative perfusion imaging of head and neck squamous cell carcinoma (SCC). Twenty-nine patients with a total of 29 pathologically proven SCC underwent a cine-mode CT perfusion acquisition covering the lesion site. The acquisition started 10 s after intravenous injection of iodinated contrast material and lasted 50 s. On a dedicated workstation, regions of interest (ROI) were traced within the SCC, on a healthy portion of tissue (H), and on the ipsilateral sternocleidomastoid muscle (M). Blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability-surface product (PS) were calculated. In SCC, BF, BV and PS were higher compared with H (p < 0.0001, p = 0.002 and p = 0.004, respectively) and M (p < 0.0001). Conversely, MTT was lower in SCC than in H (p = 0.0009) and M (p = 0.0003). All datasets were free from substantial motion artefacts and ROI misregistration phenomena. No substantial discomfort or adverse events were experienced by any of the patients. 64-row CT quantitative perfusion imaging allows head and neck SCC to be distinguished from normal tissues. (orig.)

  14. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  15. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    OpenAIRE

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients.

  16. Utility of 64-row MDCT in assessment of neonates with congenital EA and distal TEF

    Directory of Open Access Journals (Sweden)

    Hosam El-Deen Galal Mohamed El-Malah

    2015-12-01

    Conclusion: Preoperative MDCT scan with MPVR, 3D TL-VR of 64-row MDCT which is a noninvasive technique could provide more accurate information about the assessment of the origin of the fistula, the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  17. Evaluation of donor kidney using multidetector spiral computed tomography

    International Nuclear Information System (INIS)

    Full text: Multidetector spiral computed tomography (CT) is now replacing traditional angiography and intravenous pyelography (IVP) in assessing potential renal donors. The accuracy of this modality is assessed by comparison with the gold standard of surgery. A prospective study was performed. Fifteen renal donors were assessed using multidetector spiral CT between September 1999 and July 2001. Siemens-Volume Zoom and GE Lightspeed CT scanners were used. The patients subsequently underwent donor surgery and the findings at surgery were compared to that of the CT findings. The CT protocol involved pre-contrast images of the kidneys to detect calculi using 2.5mm collimation with 5 x 5mm axial reconstructions. Subsequently, an arterial phase was obtained through the kidneys to the mid pelvis with bolus tracking to optimise the timing of the contrast. Non-ionic contrast (Visipaque 270, Isovue 300, Iomeron 300) was administered at 5ml/s using a total of 150ml. Collimation of 1mm was used in obtaining images during the arterial phase, with 3 x 3mm reconstructions for printing of axial images. Axial reconstructions at 1 x 1.25mm were also performed for assessment on the workstations and for post-processing (Maximal Intensity Projection - MIP and Surface Shaded Display - SSD). A venous phase was then acquired through the kidneys using a collimation of 2.5mm, starting at 60 seconds after the initial administration of intravenous contrast. Axial reconstructions at 5 x 5mm were obtained for printing of these images. Axial reconstructions at 1.5mm x 3mm were obtained for workstation viewing plane and for postprocessing (Multiplanar Reformation - MPR) in the assessment of the renal veins. Two minutes following intravenous injection a topogram was performed to demonstrate the pelvicalyceal systems and ureters. A small field of view was used throughout, centered on the kidneys. Before the manipulation and processing of the 3D images, the axial images were assessed for the number

  18. Multidetector Computed Tomography of Cervical Spine Fractures in Ankylosing Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toeoeloe Trauma Center (Finland). Dept. of Radiology

    2004-11-01

    Purpose: To analyze multidetector computed tomography (MDCT) cervical spine findings in trauma patients with advanced ankylosing spondylitis (AS). Material and Methods: Using PACS, 2282 cervical spine MDCT examinations requested by emergency room physicians were found during a period of 3 years. Of these patients, 18 (16 M, aged 41-87, mean 57 years) had advanced AS. Primary imaging included radiography in 12 and MRI in 11 patients. Results: MDCT detected one facet joint subluxation and 31 fractures in 17 patients: 14 transverse fractures, 8 spinous process fractures, 2 Jefferson's fractures, 1 type I and 2 type II odontoid process fractures, and 1 each: atlanto-occipital joint fracture and C2 laminar fracture plus isolated transverse process and facet joint fractures. Radiographs detected 48% and MRI 60% of the fractures. MRI detected all transverse and odontoid fractures, demonstrating spinal cord abnormalities in 72%. Conclusion: MDCT is superior to plain radiographs or MRI, showing significantly more injuries and yielding more information on fracture morphology. MRI is valuable, however, in evaluating the spinal cord and soft-tissue injuries. Fractures in advanced AS often show an abnormal orientation and are frequently associated with spinal cord injuries. In these patients, for any suspected cervical spine injuries, MDCT is therefore the imaging modality of choice.

  19. Multidetector computed tomography diagnosis of adult elbow fractures

    Energy Technology Data Exchange (ETDEWEB)

    Haapamaki, V.V.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toolo (Finland). Dept. of Radiology

    2004-02-01

    To assess acute phase multidetector computed tomography (MDCT) findings in elbow traumas. Fifty-six patients (32 M, 24 F, age 16 to 88 years, mean 44 years) underwent MDCT of the elbow due to an acute trauma during a time period of 34 months. A total of 65 fractures and 3 main fracture types were established: 16 (25%) ulnar coronoid process fractures, 13 (20%) radial head fractures, and 12 (18%) humeral supracondylar fractures. Three main injury mechanisms were falling (38 (68%) patients), falling from high places (6 (11%) patients), and traffic accidents (5 (9%) patients). In 6 (11%) patients, MDCT revealed 13 occult fractures in the elbow joint compared to primary radiography. In four (7%) patients a displaced fracture fragment was detected in primary radiography, but the origin of the fragment was unclear. In all four cases, MDCT revealed the origin of the fragment. Radiography remains the primary imaging modality in elbow trauma, but in complex fracture patterns, where the extent of the fractures and the position or origin of dislocated fragments is not clear by radiography, the MDCT is a recommended complementary examination.

  20. Multidetector computed tomography findings of spontaneous renal allograft ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Basaran, C. [Department of Radiology, Baskent University Faculty of Medicine, Ankara (Turkey)], E-mail: ceylab@baskent-ank.edu.tr; Donmez, F.Y.; Tarhan, N.C.; Coskun, M. [Department of Radiology, Baskent University Faculty of Medicine, Ankara (Turkey); Haberal, M. [Department of General Surgery, Baskent University Faculty of Medicine, Ankara (Turkey)

    2009-05-15

    Aim: To describe the characteristics of spontaneous renal allograft rupture using multidetector computed tomography (MDCT). Method: Five patients with spontaneous renal allograft rupture, as confirmed by pathologic examination, were referred to our institution between 1985 and 2008. The clinical records and preoperative MDCT findings of the patients were studied retrospectively. Results: Clinical and/or histological findings were consistent with acute rejection in all cases. Using MDCT, disruption of the capsular integrity and parenchymal rupture was seen in four patients. Four of the five patients showed decreased enhancement and swollen grafts. Perirenal (n = 4), subcapsular (n = 1), and intraparenchymal (n = 1) haematomas were also seen. In the patient with an intraparenchymal haematoma there was no disruption of capsular integrity, but capsular irregularities were seen near the haematoma. Conclusion: MDCT is a useful investigative tool for the evaluation of suspected spontaneous renal allograft rupture. As well as a swollen graft, disruption of the capsule, parenchyma, and/or haematoma should prompt the radiologist to consider this diagnosis.

  1. Multidetector computed tomography in acute lower gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    John Palma

    2010-11-01

    Full Text Available John Palma, Marius Mihaila, Frank PilleulDépartement de Radiologie Digestive et des Urgences, Hôpital Edouard Herriot, Hospices Civils de Lyon, CHU, Lyon, FranceBackground: The aim of this study is to evaluate multidetector computed tomography (MDCT in acute massive lower gastrointestinal bleeding, with endoscopy and surgery as reference examinations.Methods: A single-center retrospective study involving 34 patients with acute massive lower gastrointestinal bleeding was carried out. All patients were evaluated by MDCT scan then endoscopic or surgical examinations. Sensitivity, specificity, and positive and negative predictive values of MDCT scan were calculated using the extravasation of the contrast agent as the main criterion.Results: Extravasation of the contrast agent was found in 30 of 34 patients (88%. The bleeding site seen on CT was always the same as on endoscopic or surgical examinations (100%. Sensitivity of MDCT scan was 94%, specificity 100%, positive predictive value 100%, and negative predictive value 50% (P < 0.001. Twelve diverticulum bleedings were seen on MDCT scan compared with 13 (92% on endoscopic or surgical examinations. Angiodysplasia was overestimated by MDCT scan.Conclusion: MDCT scan appears to be an excellent tool to find and localize the bleeding site in cases of acute massive lower gastrointestinal disease.Keywords: MDCT, acute lower gastrointestinal bleeding, extravasation, contrast agent

  2. The story of 12 Chachapoyan mummies through multidetector computed tomography

    International Nuclear Information System (INIS)

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean ± standard deviation; adults: 145 ± 14 cm, adolescents: 116 ± 17 cm, 2.5 years old child: 72 cm, newborns: 41 ± 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  3. The story of 12 Chachapoyan mummies through multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Klaus M., E-mail: klaus.friedrich@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan, E-mail: stefan.nemec@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Czerny, Christian, E-mail: christian.czerny@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Fischer, Helga, E-mail: helga.fischer@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Plischke, Sonja, E-mail: sonja.plischke@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Gahleitner, Andre, E-mail: andre.gahleitner@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Viola, Thomas Bence, E-mail: bence.viola@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Imhof, Herwig, E-mail: herwig.imhof@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Seidler, Horst, E-mail: horst.seidler@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Guillen, Sonja [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria)

    2010-11-15

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean {+-} standard deviation; adults: 145 {+-} 14 cm, adolescents: 116 {+-} 17 cm, 2.5 years old child: 72 cm, newborns: 41 {+-} 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  4. Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves

    NARCIS (Netherlands)

    Symersky, P.; Budde, R.P.; Prokop, M.; Mol, B.A. de

    2011-01-01

    BACKGROUND AND AIM OF THE STUDY: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). METHODS: Bjor

  5. Multidetector-Row Computed Tomography Imaging Characteristics of Mechanical Prosthetic Valves

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Prokop, Mathias; de Mol, Bas A. J. M.

    2011-01-01

    Background and aim of the study: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). Methods: Bjor

  6. Imaging features of double aortic arch shown by multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    We present a three-dimensional reconstructed image of vascular ring in a 2.5-month-old patient, which was obtained using multidetector computed tomography (MDCT). MDCT angiography made an accurate diagnosis of this life-threatening, but correctable, anomaly in an infant with a stridor, repeated respiratory infections and episodes of apnea

  7. Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Chowdhury, Shahryar M. [Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Fox, Mary A. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Pulmonary embolism is a life-threatening condition affecting people of all ages. Multidetector row CT pulmonary angiography has improved the imaging of pulmonary embolism in both adults and children and is now regarded as the routine modality for detection of pulmonary embolism. Advanced CT pulmonary angiography techniques developed in recent years, such as dual-energy CT, have been applied as a one-stop modality for pulmonary embolism diagnosis in children, as they can simultaneously provide anatomical and functional information. We discuss CT pulmonary angiography techniques, common and uncommon findings of pulmonary embolism in both conventional and dual-energy CT pulmonary angiography, and radiation dose considerations. (orig.)

  8. Comparison of Reconstruction Intervals in Routine ECG-Pulsed 64-Row-MSCT Coronary Angiography in Frequency Controlled Patients

    International Nuclear Information System (INIS)

    Purpose. In light of the increasing use and acceptance of multislice computed tomography (MSCT) coronary angiography it was the purpose of this study to compare reconstruction intervals used in a routine ECG-pulsed MSCT coronary artery angiography setting with frequency controlled patients. Methods. Examinations were performed on a Siemens Somatom Sensation 64 scanner with a total of 110 ml of contrast agent and ECG pulsing (interval from 40% to 70%) after oral application of a β-blocker if the heart rate was higher than 65 bpm. All human subjects were referred for the evaluation of suspected coronary artery disease. Coronary artery segments were evaluated by two experienced radiologists in a consensus reading. A ranking of diagnostic image quality (from 1 (no evaluation possible) to 5 (excellent image quality)) was statistically evaluated by Wilcoxon Signed Rank Test. Results. In 45 patients (30 male, 15 female, age 63.8 ± 12.1 years) we detected a significant advantage of the 60% reconstruction interval over 40%, 50%, and 70% (for each p < 0.05). In cases of sudden arrhythmia or movement during the scan, additional reconstruction intervals within the ECG-pulsed reconstruction intervals remained necessary for diagnosis. Conclusion. In a routine diagnostic setting with frequency controlled patients and ECG pulsing the 60% reconstruction interval can be considered superior for the initial diagnosis in 64-row multislice computed tomography coronary angiography. However, further information can be derived from various reconstruction intervals such as 40% and 70%

  9. Multidetector-row computed tomography in the planning of abdominal perforator flaps.

    Science.gov (United States)

    Masia, J; Clavero, J A; Larrañaga, J R; Alomar, X; Pons, G; Serret, P

    2006-01-01

    An accurate preoperative evaluation of the vascular anatomy of the abdominal wall is extremely valuable in improving the surgical strategy in abdominal perforator flaps. The multidetector-row computer tomography offers thin slice coverage of extended volumes with an extremely high spatial resolution. From October 2003 to December 2004, 66 female patients had breast reconstruction surgery in our department using the deep inferior epigastric artery perforator flap. Our multidetector-row computer tomography studies were performed using a 16-detector-row computer tomography scanner. The image assessment was carried out using the following protocol: we first identified the best three perforators from each side of the abdomen. Then we conducted a three-dimensional reconstruction of the abdomen by identifying exactly where the three best perforators emerged from the rectus abdominis fascia. We then transferred the data obtained from the image to the patient using a coordinate system. In addition, we also placed the dominant perforators in the patient by using a conventional hand-held Doppler. During the operation we compared intra-operative findings, Doppler results and computer tomography outcomes. Neither false positive nor false negative results were found in the computer tomography outcome. Multidetector-row computer tomography provides us with an easy method of interpreting the virtual anatomic dissection in three dimensions. It has high sensitivity and specificity and provides a good quality evaluation of the perforator vessels. This information allows reduction of operating time and safer performance of surgery. The multidetector-row computer tomography is a highly effective tool in the preoperative study of abdominal perforator flaps. PMID:16716952

  10. Diagnostic ability of Barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    International Nuclear Information System (INIS)

    Objectives: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index), calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. Methods: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. Results: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy) met the inclusion criteria for the study. The mean Barrett's index values (±SD) were 64.47% ± 6.06% and 49.44% ± 10.94% in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy. (author)

  11. Hemobilia in a child due to right hepatic artery pseudoaneurysm: Multidetector-row computed tomography demonstration

    Directory of Open Access Journals (Sweden)

    Nisar A Wani

    2011-01-01

    Full Text Available We present a case of a 12-year-old boy who developed upper gastrointestinal bleeding in the form of hematemesis and melena 1 month after blunt trauma to liver. Computed tomography (CT angiography with multidetector-row CT demonstrated pseudoaneurysm of right hepatic artery related to old liver laceration to be the cause of the bleeding. Pseudoaneurysm was resected using the roadmap provided by CT angiography findings.

  12. Post-operative evaluation of endo vascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Thomaz, Fabiana Barroso; Magalhaes, Fabio Vargas; Magalhaes, Isabela Ferreira de; Caramalho, Monica Ferreira; Kuroki, Iugiro Roberto [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil). Unit of Computed Tomography]. E-mail: fabianabt@terra.com.br; Lopez, Gaudencio Espinosa [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). School of Medicine. Dept. of Surgery; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteri, RJ (Brazil). Dept. of Radiology; Domingues, Romeu Cortes [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2008-07-15

    Objective: The present study was aimed at evaluating endo vascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography. Materials and methods: Multidetector computed tomography angiography studies of 166 patients were retrospectively analyzed. The sample included 137 men and 29 women with mean age of 73 years who had undergone endovascular treatment for abdominal aortic aneurysm in the period between June 2005 and August 2006. Images were acquired in a 64-channel multidetector tomograph adopting the following parameters: 0.625 mm collimation, pitch 0.6-1, 300-400 mAs, and 120 kV. A nonionic iodinated contrast agent (350 mg/ml) was injected by infusion pump at a rate of 4 ml/s to 5 ml/s and a variable amount of 70 ml to 100 ml. The studies were evaluated for the presence of complications. Results: Among the 166 cases, 93 patients did not present complications and 73 presented the following findings: endoleak (n=37), circumferential thrombosis (n=29), angulation (n=17), presence of collection at the puncture site (n=10), graft migration (n=7), dissection of access vessels (n=7) and occlusion (n=6). Conclusion: In summary, endoleak was the most prevalent complication in the present series, with type II endoleak being most frequently found. (author)

  13. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings; Classificacao de Bosniak das lesoes cisticas renais segundo achados na tomografia computadorizada multidetectores

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da, E-mail: maiachristiana@globo.com [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil); Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos [Clinica de Medicina Nuclear e Radiologia de Maceio (MedRadiUS), Maceio, AL (Brazil)

    2014-03-15

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  14. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Onbas, Omer; Aliagaoglu, Cihangir; Calikoglu, Cagatay; Kantarci, Mecit; Atasoy, Mustafa; Alper, Fatih [Ataturk University, Erzurum (Turkmenistan)

    2006-03-15

    Neurofibromatosis type 1 disease if characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography.

  15. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  16. Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Zacho, Mette; Lilleoer, Nikolaj Thomas; Kelbaek, Henning;

    2012-01-01

    The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related...... to the severity of stenosis in the native coronary vessel. One hundred and forty-two patients who had undergone coronary artery bypass grafting including implantation of LITA as conduit to the left anterior descending artery were studied 5 years after surgery. Arterial graft patency and geometry was assessed...

  17. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  18. Prognostic implications of nonobstructive coronary plaques in patients with non-ST-segment elevation myocardial infarction: a multidetector computed tomography study

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Kühl, Jørgen T;

    2011-01-01

    We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events.......We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events....

  19. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  20. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation. PMID:25501090

  1. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    Science.gov (United States)

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  2. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    Science.gov (United States)

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. PMID:27403020

  3. Comparison between clinical indicators of transmembrane oxygenator thrombosis and multidetector computed tomographic analysis.

    Science.gov (United States)

    Panigada, Mauro; L'Acqua, Camilla; Passamonti, Serena Maria; Mietto, Cristina; Protti, Alessandro; Riva, Roberto; Gattinoni, Luciano

    2015-04-01

    This study aims to assess whether multidetector computed tomography (MDCT) could accurately confirm the clinical suspicion of transmembrane oxygenator thrombosis (MOT) during extracorporeal membrane oxygenation (ECMO). Twenty-seven oxygenators were examined using MDCT at the end of patient treatment. Transmembrane oxygenator thrombosis was suspected in 15 of them according to the presence of at least 2 of the following clinical indicators: (1) increase in d-dimer, (2) decrease in platelet count, (3) decrease in oxygenator performance, and (4) presence of clots on the surface of the oxygenator. Transmembrane oxygenator thrombosis was confirmed by MDCT in 5 (33%) of them. Transmembrane oxygenator thrombosis was unexpectedly found in 5 (41%) of the remaining 12 oxygenators not suspected for MOT. Eight (80%) of these oxygenators had clots accounting for less than 1% of total volume. Clots were mainly detectable at the apical corner of the oxygenator, most likely due to greater blood stasis. We found a significant increase in d-dimer and in membrane oxygenator shunt and a decrease in platelet count from the start to the discontinuation of ECMO. Hemostatic abnormalities significantly reverted 48 hours after oxygenator removal, suggesting the role of ECMO in activation of the coagulation cascade. Multidetector computed tomographic scan could not accurately confirm the clinical suspicion of MOT.

  4. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Directory of Open Access Journals (Sweden)

    Carlos Fernando de Mello Júnior

    2016-06-01

    Full Text Available Abstract Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  5. Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Mário L. R. Monteiro

    2008-01-01

    Full Text Available OBJECTIVES: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index, calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. RESULTS: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy met the inclusion criteria for the study. The mean Barrett's index values (± SD were 64.47% ± 6.06% and 49.44% ± 10.94%in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy.

  6. Visibility of sutures of the orbit and periorbital region using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gufler, Hubert; Preis, Markus; Koesling, Sabrina [Dept. of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Halle (Germany)

    2014-12-15

    Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube current from 25 to 370 mAs, depending on the CT indication. The visibility of sutures was estimated according to a 4-point scale from 'not visible to well visible' The chi-squared test was used to test the association of the visibility of sutures with the slice thickness, tube current, and age of patients. Statistical significance was assumed at p < 0.05. Overall, best visibility was found for the sutura frontozygomatica (98%), sutura frontonasalis (88.5%), and sutura sphenozygomatica (71.5%), followed by the sutura zygomaticomaxillaris (65.8%), sutura temporozygomatica (41.8%), sutura frontomaxillaris (44.5%), and sutura sphenofrontalis (31%). Poor visibility was found for the sutura frontolacrimalis (16.8%) and sutura frontoethmoidalis (1.3%). The sutura ethmoidomaxillaris, sutura lacrimomaxillaris, and sutura ethmoidolacrimalis were not visible. Although the sutures of the superior, lateral, and inferior orbit are well visible, those of the medial orbit are poorly visible on CT scans.

  7. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Energy Technology Data Exchange (ETDEWEB)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil); Reboucas, Rafael Batista, E-mail: severinoaires@hotmail.com [Faculdade de Ciencias Medicas da Paraiba, Joao Pessoa, PB (Brazil)

    2016-05-15

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  8. Anomalies of abdominal organs in polysplenia syndrome: Multidetector computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Won; Lee, Yong Seok; Jung, Jin Hee [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University School of Medicine, Goyang (Korea, Republic of)

    2016-02-15

    Polysplenia syndrome is a rare situs ambiguous anomaly associated with multiple spleens and anomalies of abdominal organs. Because most of the minor anomalies do not cause clinical symptoms, polysplenia syndrome is detected incidentally in the adults. Anomalies of abdominal organs may include multiple spleens of variable size or right-sided spleen, large midline or left-sided liver, midline gallbladder, biliary tract anomalies, short pancreas, right-sided stomach, intestinal malrotation, inferior vena cava interruption with azygos or hemiazygos continuation, and a preduodenal portal vein. As the multidetector computed tomography is increasingly used, situs anomalies will likely to be found with greater frequency in the adults. Therefore, radiologists should become familiar with these rare and peculiar anomalies of abdominal organs in polysplenia syndrome.

  9. Usefulness of multidetector computed tomography in the diagnosis of lower gastrointestinal diverticular hemorrhage

    International Nuclear Information System (INIS)

    The aim of this study was to evaluate the diagnostic ability of Multidetector Computed Tomography (MDCT) for lower gastrointestinal diverticular hemorrhage. Three radiologists reviewed MDCT findings in 12 cases and investigated the relationship between imaging findings and the patients' blood pressure, volume of transfusion, and treatments applied. MDCT examination demonstrated ''extravasation'' in 7 cases, and luminal abnormalities, id est (i.e.), ''high density area with bubble'', ''fluid collection'' and ''clot'' in 5, 8, and 4 cases, respectively. Four of six cases who required blood transfusion demonstrated extravasation. The systolic blood pressure of three cases with extravasation was below 95 mmHg. Extravasation on MDCT which was frequently observed in patients with hypotension and/or requiring blood transfusion, was highly specific for diagnosing the bleeding site. MDCT was also useful for procedural planning in IVR, endoscopic and surgical management. (author)

  10. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  11. Multi-detector Computed Tomography Angiography of the Hepatic Artery in Liver Transplant Recipients

    Energy Technology Data Exchange (ETDEWEB)

    Boraschi, P.; Donati, F.; Cossu, M.C.; Gigoni, R.; Vignali, C.; Filipponi, F.; Bartolozzi, C.; Falaschi, F. [Pisa Univ. Hospital (Italy). 2nd Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. MATERIAL AND METHODS: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. RESULTS: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. CONCLUSION: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.

  12. Evaluation of visibility of lumen of coronary stents by CT coronary angiography using multi-detector row CT in our hospital

    International Nuclear Information System (INIS)

    Many experiments of evaluation of coronary stents by CT coronary angiography (CTCA) using multi-detector row computed tomography (MDCT) are reported since the appearance of 16-row and 64-row CT. However, blooming artifact makes the assessment of lumen of coronary stent (LCS) difficult at present. The purpose of this study is to investigate the evaluation of visibility of LCS by CTCA. CTCA was performed in 25 patients who had previously undergone stent implantation scanned using 64-row CT, and images of 32 stents were obtained. All images were classified into 4 grades (4: excellent, 3: good, 2: fair, 1: poor) according to their visibility of LCS. We investigated the correlation of stent characteristics and backgrounds (diameter, material and thickness of strut, the period from stent implantation to CTCA, the location of stent, and whether calcification or not) with the grade of visibility. We found the conditions of good visibility of LCS were the diameter >3.5 mm (ratio of ≥grade 3 was 77.8%=14/18 stents), thin strut (<100 μm), and no calcification (ratio of ≥grade 3 was 87.5%=14/16 stents). We expected that CTCA using MDCT will be established useful examination of evaluation of LCS in future. (author)

  13. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    OpenAIRE

    Jong Gyu Kim; Soo Hyang Lee

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients...

  14. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  15. Can contrast-enhanced ultrasonography replace multidetector-computed tomography in the detection of liver metastases from colorectal cancer?

    DEFF Research Database (Denmark)

    Larsen, Lars P.S.; Rosenkilde, Mona; Christensen, Henrik;

    2007-01-01

    PURPOSE: To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC). MATERIALS AND METHODS: Candidates for this prospective study were 461...... consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions...... liver metastases in 54 patients (14.8%). Multidetector CT found significantly more metastases than CEUS in 15 (28%) of the patients (p=0.02). In a patient-by-patient analysis MDCT had a non-significantly higher sensitivity in the detection of liver metastases compared to CEUS (0.89 versus 0.80, p=0...

  16. Advances of multidetector computed tomography in the characterization and staging of renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Athina; C; Tsili; Maria; I; Argyropoulou

    2015-01-01

    Renal cell carcinoma(RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography(CT) is considered the examination of choice for thedetection and staging of RCC. Multidetector CT(MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and threedimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment.

  17. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Jeong, Yong Yeon [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2015-06-15

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall.

  18. Preoperative Diagnosis of Extraglandular Invasion of Thyroid Papillary Carcinoma: High Resolution Sonography versus Multidetector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Hong, Hyun Pyo; Kwag, Hyon Joo; Kook, Shin Ho; Yun, Ji Sup; Kim, Dong Hoon [Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2009-03-15

    To compare the diagnostic efficacy of high-resolution sonography (HRS) and multidetector computed tomography (MDCT) in determining the presence of extraglandular invasion of thyroid papillary cancer and to define ultrasound (US) features of perithyroidal invasion that correlate with histopathological findings. We prospectively evaluated extracapsular invasion in 177 thyroid cancer patients using both HRS and MDCT. Receiver operating characteristics (ROC) were assessed with a four-point confidence scale (0 = no extracapsular invasion:1 = possible invasion:2 = probable invasion:3 = definite invasion) by two reviewers for each imaging modality. Sensitivity, specificity, and accuracy were analyzed for each modality, along with interobserver variability. MDCT had a mean area under the ROC curve larger than that of HRS (HRS = 0.733, MDCT = 0.807, p < 0.05). HRS and MDCT were significantly different with regard to diagnostic sensitivity, specificity, and accuracy for extrathyroidal extension (p < 0.05: HRS = 75.7%, 66.1%, and 69.8%, respectively: MDCT = 86.7%,69.7%, and 76%, respectively). Interobserver reliability was greater for MDCT than for HRS (kappa value, 0.861 versus 0.429). The cutoff value used in HRS for estimating the status of perithyroidal invasion was 2. Conclusion: HRS may be useful for preoperative investigation of thyroid papillary carcinoma extension, but it was inferior to MDCT because of lower diagnostic accuracy and lower interobserver reliability

  19. Major venous anomalies are frequently associated with horseshoe kidneys. Value of multidetector computed tomography

    International Nuclear Information System (INIS)

    Several cases of horseshoe kidney with anomalous inferior vena cava (IVC) have been described, but there have been no reports of the incidence and variation of anomalous IVC in patients with horseshoe kidneys detected using multidetector row computed tomography (MDCT). 105 patients with horseshoe kidneys were evaluated with MDCT and a variety of venous anomalies were identified in 30 patients (28.6%). Anatomical variations of the renal vein were identified in 24 patients (22.9%), which was no higher than the reported incidence in the general population. However, variations of the IVC were identified in 6 patients (5.7%), which was a higher incidence than expected to be found in the general population: 1 pre-isthmic IVC with retrocaval ureter, 2 double IVCs posterior to the horseshoe kidney, 2 left IVCs posterior to the horseshoe kidney, and 1 azygos continuation of the IVC. Horseshoe kidneys are frequently found in patients with other venous, and particularly IVC, anomalies, which should be evaluated using MDCT as part of treatment planning. (author)

  20. Utility of multidetector computed tomography for the hemodynamic diagnosis of esophago-gastric varices

    International Nuclear Information System (INIS)

    Diagnosis based on portal hemodynamics is essential for the clinical treatment of esophago-gastric varices; multidetector computed tomography (MDCT) is used at our institution for this purpose. Two analytic methods are used in conjunction with MDCT: volume rendering (VR) and partial maximum intensity projection (MIP). At present, the partial MIP method is more useful than the VR method, as partial MIP images clearly show the feeding and collateral veins in minute detail. Improvements in the analyzing power of MDCT have permitted the visualization of feeding veins as well as faint images of collateral veins associated with the varices. These images can be seen with a high degree of probability on MDCT images obtained using endoscopic varicerography during injection sclerotherapy. Diagnosis of the portal hemodynamics using MDCT prior to clinical treatment is likely to be an effective clinical option. However, numerous images are needed for the diagnosis of portal hemodynamics using partial MIP, and a detailed map of the portal hemodynamics is required to understand this diagnosis. Our objective is to use VR to overcome these diagnostic problems, since the use of a single image, which can be constructed within minutes, should permit the portal hemodynamics to be visualized. (author)

  1. Role of multidetector computed tomography in evaluation of suspected bronchogenic carcinoma

    Directory of Open Access Journals (Sweden)

    Deepika Yadav

    2016-03-01

    Results: Patient's age ranged between 45 to 80 years with the mean age of 59 years. There was significant male preponderance (26 males with smoking being the most common risk factor (83.3%. Cough (83.3% and dyspnea (80% were the commonest symptoms. The most common radiological manifestation was central hilar mass seen in 20 (66.6% patients and peripheral mass seen in 10 (33.3% patients. Provisional CT diagnosis was found in complete correlation with pathological diagnosis made on bronchoscopy biopsy/ CT guided FNAC in 28 (93.3% patients and others 2 patients diagnosed as pulmonary tuberculosis, non caseating granulomatous inflammation on histopathological diagnosis. Squamous cell carcinoma was the commonest histopathological type seen in 16 (53.3% patients followed by adenocarcinoma seen in 8 (26.6% patients. Conclusions: Multidetector computed tomography plays an important role in evaluating and staging of bronchogenic carcinoma.CT had the high predictive value in evaluating bronchogenic carcinoma and found to be 93.3%. [Int J Res Med Sci 2016; 4(3.000: 829-835

  2. Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, Thomas S. [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: tskaarup@yahoo.com; Kofoed, Klaus F. [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: kkofoed@dadlnet.dk; Moller, Daniel V. [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: DVEGA@gmx.net; Ersboll, Mads [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: ersboell@stud.ku.dk; Kuehl, Tobias [Department of Cardiology, The Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: tobiaskh@gmail.com; Recke, Peter von der [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: peter.von.der.recke@rh.regionh.dk; Kober, Lars [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: lk@heart.dk; Nielsen, Michael B. [Department of Radiology, Diagnostic Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: mbn@dadlnet.dk; Kelbaek, Henning [Department of Cardiology, Heart Centre, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)], E-mail: henning.kelbaek@rh.regionh.dk

    2009-10-15

    Background: Multidetector computed tomography (MDCT) of the heart provides both anatomical and functional information. The objective of this study was to evaluate the accuracy of quantitative assessment of left ventricular contractile function in relation to two-dimensional transthoracic echocardiography (TTE). Materials and methods: Sixty-four patients with known or suspected coronary artery disease underwent ECG-gated 64-slice MDCT and TTE. Regional left ventricular contractile function was measured by percent systolic wall thickening (SWT) in 16 myocardial segments using MDCT, and compared with visual evaluation of wall motion score (WMS) by TTE. Global SWT by MDCT was calculated as the mean SWT of all myocardial segments and compared with wall motion index (WMI) by TTE. Results: Eight hundred and eleven segments (81%) were classified as normokinetic, 142 (14%) as hypokinetic, 41 (4%) as akinetic and 5 (0.5%) as dyskinetic by TTE. A significant inverse linear trend was found between regional SWT by MDCT and WMS by TTE (p < 0.001). Sensitivity and specificity for the identification of regional abnormalities of contractile function were 76% and 78%, respectively. A linear correlation between global SWT by MDCT and WMI by TTE was found (r = -0.8, p < 0.001). Sensitivity and specificity for the identification of WMI > 1.5 using global SWT was 91% and 94%, respectively. Conclusion: Quantification of systolic wall thickening by MDCT provides functional information, which is well correlated to visual assessment of global left ventricular contractile function by TTE.

  3. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    Science.gov (United States)

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  4. Clinical impact of multidetector computed tomography before double-balloon enteroscopy for obscure gastrointestinal bleeding

    Institute of Scientific and Technical Information of China (English)

    Hsu-Heng Yen; Yang-Yuan Chen; Chia-Wei Yang; Chi-Kuang Liu; Maw-Soan Soon

    2012-01-01

    AIM:To evaluate the clinical impact of multidetector computed tomography (MDCT) before double-balloon endoscopy (DBE) for patients with obscure gastrointestinal bleeding (OGIB).METHODS:A retrospective analysis of prospectively collected cases with DBE and MDCT for overt OGIB was conducted from April 2004 to April 2010 at Changhua Christian Hospital.We evaluated the clinical impact of MDCT on the subsequent DBE examinations and the diagnostic yields of both MDCT and DBE respectively.RESULTS:From April 2004 to April 2010,a total of 75 patients underwent DBE for overt OGIB.Thirty one cases received MDCT followed by DBE for OGIB.The overall diagnostic yields of DBE and MDCT was 93.5% and 45.2%.The MDCT had a high diagnostic yield of tumor vs non-tumor etiology of OGIB (85.7% vs 33.3%,P =0.014).Additionally,the choice of initial route of DBE was correct in those with a positive MDCT vs negative MDCT (100% vs 52.9%,P =0.003).CONCLUSION:This study suggests MDCT as a triage tool may identify patients who will benefit from DBE and aid the endoscopist in choosing the most efficient route.

  5. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Hans [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Klinikum Brandenburg, Department of Cardiology, Angiology, and Pulmonology, Brandenburg an der Havel (Germany); Frieler, Katja [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Potsdam Institut fuer Klimaforschung, Potsdam (Germany); Schlattmann, Peter [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Hamm, Bernd [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Dewey, Marc [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology (Germany)

    2010-12-15

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm{sup 3} at two time points 25 {+-} 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P < 0.001) increased from baseline (medians/interquartile ranges = 21/15-39, 7/3-20 and 36/16-69 mm{sup 3}) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm{sup 3}). Statins significantly slowed the growth of non-calcified plaques (statin coefficient {beta} = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  6. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siebert, E.; Bohner, G. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany); Dewey, M.; Bauknecht, C. [Department of Radiology, Charite Universitary Medicine Berlin (Germany); Klingebiel, R. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany)], E-mail: randolf.klingebiel@charite.de

    2010-01-15

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  7. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Energy Technology Data Exchange (ETDEWEB)

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants *

    Science.gov (United States)

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. PMID:26929461

  9. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Directory of Open Access Journals (Sweden)

    Severino Aires Araujo Neto

    2016-02-01

    Full Text Available Abstract Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications.

  10. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    International Nuclear Information System (INIS)

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  11. Mediastinite aguda: aspectos de imagem pós-cirurgias cardíacas na tomografia computadorizada de multidetectores Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Directory of Open Access Journals (Sweden)

    Clarissa Aguiar de Macedo

    2008-08-01

    Full Text Available Mediastinite pós-cirurgias torácicas é definida como a infecção dos órgãos e tecidos do espaço mediastinal, ocorrendo em 0,4% a 5% dos casos. A gravidade da infecção pós-operatória varia desde infecção de tecidos superficiais da parede torácica até mediastinite fulminante com envolvimento esternal. O critério diagnóstico da tomografia computadorizada para mediastinite aguda pós-cirúrgica é a presença de coleção mediastinal, podendo estar associada ou não a anormalidades periesternais como edema/borramento de partes moles, separação dos segmentos esternais com reabsorção óssea marginal, esclerose e osteomielite. Achados associados incluem linfonodomegalias, consolidações pulmonares e derrame pleural e pericárdico. Pequenas coleções e gás mediastinais podem ser usualmente encontradas em pós-operatório recente de cirurgias torácicas sem a presença de infecções, limitando a eficácia da tomografia computadorizada nas duas primeiras semanas. Após esse período, a tomografia alcança quase 100% de sensibilidade e especificidade. Pacientes com suspeita clínica de mediastinite devem ser submetidos a exame de tomografia para pesquisa de coleções, identificando a extensão da doença e sua natureza. A versão de multidetectores propicia recursos de reconstruções em diversos planos e janelas, contribuindo especialmente para o estudo do esterno.Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues

  12. Diagnostic value of multidetector computed tomography for renal sinus fat invasion in renal cell carcinoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cherry, E-mail: cherrykim0505@gmail.com; Choi, Hyuck Jae, E-mail: choihj@amc.seoul.kr; Cho, Kyoung-Sik, E-mail: kscho@amc.seoul.kr

    2014-06-15

    Objective: Although renal sinus fat invasion has prognostic significance in patients with renal cell carcinomas (RCCs), there are no previous studies about the value of multidetector computed tomography (MDCT) about this issue in the current literature. Materials and methods: A total of 863 consecutive patients (renal sinus fat invasion in 110 patients (12.7%)) from single institutions with surgically-confirmed renal cell carcinoma who underwent MDCT between 2010 and 2012 were included in this study. The area under the curves (AUCs) of the receiver operating characteristic (ROC) analysis was used to compare diagnostic performance. Reference standard was pathologic examination. Weighted κ statistics were used to measure the level of interobserver agreement. Multivariate logistic regression model was used to find the predictors for renal sinus fat invasion. Image analysis was first performed with axial-only CT images. A second analysis was then performed with both axial and coronal CT images. A qualitative analysis was then conducted by two reviewers who reached consensus regarding tumor size, decreased perfusion, tumor margin, vessel displacement, and lymph node metastasis. The reference standard was pathologic evaluation. Results: The AUCs of the ROC analysis were 0.881 and 0.922 for axial-only images and 0.889 and 0.902 for combined images in both readers. The AUC of tumor size was 0.884, a similar value to that of the reviewers. In multivariate analysis, tumor size, a linear-nodular or nodular type of fat infiltration, and an irregular tumor margin were independent predicting factors for perinephric fat invasion. Conclusion: MDCT shows relatively high diagnostic performance in detecting perinephric fat invasion of RCC but suffers from a relatively low PPV related to low prevalence of renal sinus fat invasion. Applying tumor size alone we could get similar diagnostic performance to those of radiologists. Tumor size, fat infiltration with a nodular appearance, and

  13. Imaging features of solid pseudopapillary tumor of the pancreas on multi-detector row computed tomography

    Institute of Scientific and Technical Information of China (English)

    Deng-Bin Wang; Qing-Bing Wang; Wei-Min Chai; Ke-Min Chen; Xia-Xing Deng

    2009-01-01

    AIM:To retrospectively analyze the imaging features of solid-pseudopapillary tumors (SPTs) of the pancreas on multi-detector row computed tomography (MDCT) and define the imaging findings suggestive of malignant potential.METHODS: A total of 24 consecutive cases with surgically and pathologically confirmed SPTs of the pancreas underwent preoperative abdominal MDCT studies in our hospital. All axial CT images, CT angiographic images, and coronally and sagittally reformed images were obtained. The images were retrospectively reviewed at interactive picture archiving and communication system workstations. RESULTS: Of the 24 cases of SPTs, 11 cases (45.8%) occurred in the pancreatic head and seven (29.1%) in the tail. Eighteen were pathologically diagnosed as benign and six as malignant. MDCT diagnosis of SPTs was well correlated with the surgical and pathological results (Kappa = 0.6, P < 0.05). The size of SPTs ranged from 3 to 15 cm (mean, 5.8 cm). When the size of the tumor was greater than 6 cm (including 6cm), the possibilities of vascular (8 vs 1) and capsular invasion (9 vs 0) increased significantly ( P < 0.05). Two pathologically benign cases with vascular invasion and disrupted capsule on MDCT presented with local recurrence and hepatic metastases during follow-up about 1 year after the resection of the primary tumors.CONCLUSION: Vascular and capsular invasion with superimposed spread into the adjacent pancreatic parenchyma and nearby structures in SPTs of the pancreas can be accurately revealed by MDCTpreoperatively. These imaging findings are predictive of the malignant potential associated with the aggressive behavior of the tumor, even in the pathologically benign cases.

  14. Assessment of myocardial viability using multidetector computed tomography in patients with reperfused acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Choi, B.J. [Department of Cardiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Kang, D.K., E-mail: kdklsm@ajou.ac.kr [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Sun, J.S. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2012-08-15

    Aim: To assess the prognostic value of 64-section multidetector computed tomography (MDCT) to predict follow-up myocardial dysfunction and functional recovery after reperfusion therapy in patients with acute myocardial infarction (MI) as defined by echocardiography. Materials and methods: After reperfusion therapy for acute MI, 71 patients underwent two-phase contrast-enhanced MDCT and follow-up echocardiography. MDCT findings were compared with echocardiographic findings using kappa statistics. The areas under the receiver operating characteristic curves (AUCs) and the odds ratios (ORs) of early perfusion defects (EPD), delayed enhancement (DE), and residual perfusion defects (RPD) for predicting follow-up myocardial dysfunction and functional recovery were calculated on a segmental basis. Results: The presence of transmural EPD (EPD{sub TM}) or RPD showed good agreement (k = 0.611 and 0.658, respectively) with follow-up myocardial dysfunction, while subendocardial EPD (EPD{sub sub}) or subendocardial DE (DE{sub sub}) showed fair agreement with follow-up myocardial dysfunction (k = 0.235 and 0.234, respectively). The AUC of RPD (0.796) was superior (p < 0.001 and 0.031, respectively) to those of EPD{sub TM} (0.761) and DE{sub TM} (0.771). The presence of EPD{sub TM}, DE{sub TM}, and RPD were significant, independent positive predictors of follow-up myocardial dysfunction (OR = 6.4, 1.9, and 9.8, respectively). EPD{sub TM} was a significant, independent negative predictor of myocardial functional recovery (OR = 0.13). Conclusion: Abnormal myocardial attenuation on two-phase MDCT after reperfusion therapy may provide promising information regarding myocardial viability in patients with acute MI.

  15. Tendon entrapments and dislocations in ankle and hindfoot fractures: evaluation with multidetector computed tomography.

    Science.gov (United States)

    Ballard, David H; Campbell, Kevin J; Blanton, Lee E; Williams, Jason T; Sangster, Guillermo; Hollister, Anne M; Simoncini, Alberto A

    2016-08-01

    The purpose of this study was to assess the incidence of tendon entrapments and tendon dislocations associated with ankle and hindfoot fractures in patients studied by multidetector computed tomography (MDCT). Additionally, we describe particular tendon injuries associated with specific fractures. This was a retrospective review of all individuals with a trauma-protocol CT for suspected ankle and/or hindfoot fractures during a consecutive 41-month time period at a single Level I Trauma Center. Each patient's images were evaluated by two radiologists and an orthopedic surgeon for tendon entrapment, tendon dislocation, and bone(s) fractured or dislocated. There were 398 patients with ankle and/or hindfoot fractures that showed tendon entrapment or dislocation in 64 (16.1 %) patients. There were 30 (46.9 %) patients with 40 tendon entrapments, 31 (48.4 %) patients with 59 tendon dislocations, and three (4.7 %) patients with both tendon entrapment and dislocation. All patients with tendon entrapments were seen with either pilon fractures and/or a combination of posterior, medial, or lateral malleolar fractures. The most frequently entrapped tendon was the posterior tibialis tendon (PTT) in 27 patients (27/30, 90.0 %). The peroneal tendons were the most frequently dislocated, representing 27 (87.1 %) of patients with tendon dislocation; all resulted from a talar or calcaneal fracture or subluxation. This study demonstrates that tendon entrapments and tendon dislocations are commonly seen in complex fractures of the ankle and hindfoot. Pilon fractures were associated with the majority of tendon entrapments, whereas calcaneus fractures were associated with the majority of tendon dislocations. PMID:27234977

  16. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mustonen, A.O.T. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Koskinen, S.K. [Research Inst. of Military Medicine, Helsinki (Finland); Kiuru, M.J. [ORTON Orthopaedic Hospital, Helsinki (Finland)

    2005-12-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately.

  17. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lessick, Jonathan, E-mail: j_lessick@rambam.health.gov.il [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Abadi, Sobhi [Medical Imaging Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Agmon, Yoram [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Keidar, Zohar [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Carasso, Shemi; Aronson, Doron [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Ghersin, Eduard [Department of Diagnostic Radiology, University of Miami, Miller School of Medicine, Miami, FL (United States); Rispler, Shmuel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Sebbag, Anat [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Israel, Ora [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Hammerman, Haim; Roguin, Ariel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel)

    2012-10-15

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition.

  18. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Chou [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tsai, Shih-Hung [Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Chang, Wei-Kuo [Division of Gasteroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Liu, Chang-Hsien [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tung, Ho-Jui [Department of Healthcare Administration, Asia University, Taichung, Taiwan (China); Hsieh, Chung-Bao [Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Huang, Guo-Shu; Hsu, Hsian-He [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Yu, Chih-Yung, E-mail: chougo2002@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China)

    2011-11-15

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  19. Scoliotic Change in Patients Having Undergone a Mastectomy: Analysis Using Multi-Detector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Sang; Kim, Hye Won; Juhng, Seon Kwan; Choi, Si Sung [Dept. of Radiology, Wankwang University School of Medicine, Iksan (Korea, Republic of)

    2011-09-15

    To evaluate the relationship between the degree of scoliotic curvature and postoperative change of the chest wall among patients who underwent a unilateral mastectomy. Subjects were comprised of 56 women who underwent chest CT and a whole spine standing anteroposterior view (WSSAP). Cobb's angle and each side of the chest wall volume, including the breast, were measured with the WSSAP and a 3-D reconstructed multi-detector computed tomography (MDCT) image. A correlation analysis was performed between the scoliotic curvature and chest wall volume asymmetry. Directional correspondence between development of scoliosis and undergoing a mastectomy was analyzed. Furthermore, a survey on patient shoulder function was performed using a questionnaire and a correlation was performed between the results of the survey and the scoliotic curvature and chest wall volume asymmetry. The findings indicate that Cobb's angles were 4.4 degree {+-} 2.7 (Mean {+-} SD, range from 0.6 to 11.4). Differences in chest wall volume were 474.64 {+-} 276.36 cm{sup 3} (Mean {+-} SD, range from 78 to 1379). No statistical significance was noted between the degree of scoliotic curvature and chest wall volume asymmetry (p > 0.05). A cross-tabulation analysis of the direction between the scoliotic curvature and mastectomy was found to be statistically significant (p < 0.001). Also, there was a significant correlation between shoulder function assessment score and the degree of scoliotic curvature (p = 0.003), while no significant correlation between shoulder function assessment score and chest wall volume asymmetry (p 0.091) could be found. Scoliotic change had a tendency to be on the opposite side of the mastectomy and had no statistically significant relationship with the volume asymmetry. Thus, 3-D reconstructed MDCT images are helpful in differentiating selective volume differences.

  20. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    International Nuclear Information System (INIS)

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition

  1. The role of multidetector computed tomography in evaluation of small bowel obstructions

    Directory of Open Access Journals (Sweden)

    Mehmet Fatih İnci

    2013-03-01

    Full Text Available Objective: The purpose of the study was to evaluate therole and additional diagnostic contribution of multi-detectorcomputed tomography (MDCT in patients with acuteabdominal pain caused by small bowel obstruction.Materials and methods: A total of 48 patients who admittedto our hospital with acute abdominal pain and underwentMDCT on suspicion of intestinal obstruction and hadabdominal surgery between January 2012 and October2012 were included to our study. MDCT images were interpretedby two experienced radiologist retrospectively.All clinical data and surgery notes also were evaluated.Patients had surgery due to penetrating or blunt abdominalinjury were excluded.Results: Of these 48 patients, 26 (54.1% were male and22 (45.9% were female. Patients’ ages ranged 25 to 71and mean age was 52±5.4 years. The causes of intestinalobstruction of patients were adhesions for 12 (46.1% patients,tumors for 7 (26.9% patients, external hernias for5 (19.2% patients, internal hernia for 1 (3.9% patient andintussusception for 1 (3.9% patient. A total concordancebetween the MDCT findings and definitive diagnosis wasfound in 26 of 23 cases and the sensitivity and specifityof MDCT in the diagnosis of small bowel obstruction werefound to be 88.5% and 90%, respectively.Conclusion: MDCT is a fast, effective and reliable imagingmethod for preoperative diagnosing small bowel obstructioncauses acute abdominal pain with the advantagesof MDCT such as multi-planar and three-dimensionalreformatted imaging.Key words: Acute abdominal pain, multi-detector computed tomography, small bowel obstruction

  2. Differentiation between tuberculosis and leukemia in abdominal and pelvic lymph nodes: evaluation with contrast-enhanced multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Ge Zhang

    2015-03-01

    Full Text Available PURPOSE: To compare the characteristics of tubercular vs. leukemic involvement of abdominopelvic lymph nodes using multidetector computed tomography (CT. MATERIALS AND METHODS: We retrospectively reviewed multidetector computed tomography features including lymph node size, shape, enhancement patterns, and anatomical distribution, in 106 consecutive patients with newly diagnosed, untreated tuberculosis (55 patients; 52% or leukemia (51 patients; 48%. In patients with leukemia, 32 (62.7% had chronic lymphocytic leukemia, and 19 (37.3% had acute leukemias; of these, 10 (19.6% had acute myeloid leukemia, and 9 (17.6% had acute lymphocytic leukemia. RESULTS: The lower para-aortic (30.9% for tuberculosis, 63.2% for acute leukemias and 87.5% for chronic lymphocytic leukemia and inguinal (9.1% for tuberculosis, 57.9% for acute leukemias and 53.1% for chronic lymphocytic leukemia lymph nodes were involved more frequently in the three types of leukemia than in tuberculosis (both with p <0.017. Tuberculosis showed peripheral enhancement, frequently with a multilocular appearance, in 43 (78.2% patients, whereas patients with leukemia (78.9% for acute myeloid leukemia and acute lymphocytic leukemia, 87.5% for chronic lymphocytic leukemia demonstrated predominantly homogeneous enhancement (both with p <0.017. For the diagnosis of tuberculosis, the analysis showed that a peripheral enhancement pattern had a sensitivity of 78.2%, a specificity of 100%, and an accuracy of 88.7%. For the diagnosis of leukemia, the analysis showed that a homogeneous enhancement pattern was associated with a sensitivity of 84.3%, a specificity of 94.5%, and an accuracy of 89.6%. CONCLUSION: Our findings indicate that the anatomical distribution and enhancement patterns of lymphadenopathy seen on multidetector computed tomography are useful for differentiating between untreated tuberculosis and leukemia of the abdominopelvic lymph nodes.

  3. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Habets, Jesse; van den Brink, Renee B. A.; Uijlings, Ruben; Spijkerboer, Anje M.; Mali, Willem P. Th. M.; Chamuleau, Steven A. J.; Budde, Ricardo P. J.

    2012-01-01

    Objectives Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. Methods ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of p

  4. The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

    OpenAIRE

    Lee, Dong-Hyeon; Youn, Ho-Joong; Shim, Sung-Bo; Lee, Sun-Hee; Jung, Jung-Im; Jung, Seung-Eun; Choi, Yun-Seok; Park, Chul-Soo; Oh, Yong-Seog; Chung, Wook-Sung; Kim, Jae-Hyung

    2009-01-01

    Background and Objectives The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). Subjects and Methods In 20 patients (mean age, 50±12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening a...

  5. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy); Scaglione, Mariano [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy)], E-mail: mscaglione@tiscali.it

    2008-03-15

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections.

  6. Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

    OpenAIRE

    Qi, Weiwei; Li, Jianying; Du, Xiangke

    2009-01-01

    Objective To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. Materials and Methods The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans...

  7. Multidetector-row spiral computed tomography in chest emergencies; MSCT bei thorakalen Notfaellen

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Leiner, T. [Maastricht University Medical Center (MUMC) (Netherlands). Department of Radiology; Mahnken, A.H. [Universitaetsklinikum Aachen (Germany). Klinik fuer Radiologische Diagnostik; RWTH Aachen (Germany). Angewandte Medizintechnik, Helmholtz-Institut fuer Biomedizinische Technik

    2009-06-15

    With ongoing advances in multidetector-row computed tomography (MDCT) using ECG gating, differentiated examination protocols have become technically feasible. For acute chest pain assessment a strict triage of patients is indispensable, as the radiation dose is approximately 3 times higher for a dedicated protocol compared to a standard chest MDCT. Clinical requests considering pathologies of the pulmonary arteries, the aortic arch and the descending aorta can safely be answered with a standard CT data set. However, for the coronary arteries as well as for the ascending aorta, ECG synchronization of the data set is required. Initial reports regarding MDCT assessment for acute chest pain report a high negative predictive value. With the latest MDCT platforms available, medical preparation is no longer necessary with the exception of sublingual application of nitroglycerine. Dedicated contrast injection protocols, however, are necessary for simultaneous opacification of the pulmonary arteries as well as of the aorta and the coronary arteries. Further prospective studies will have to provide more evidence-based data for acute chest pain assessment with MDCT and will also have to outline the cost-effectiveness of this imaging technique. (orig.) [German] Die Weiterentwicklung der Mehrschichtspiralcomputertomographie (MSCT) mit EKG-Synchronisation ermoeglicht differenzierte Untersuchungsprotokolle zur Abklaerung unklarer thorakaler Schmerzereignisse, erfordert jedoch aufgrund der gegenueber einer herkoemmlichen CT des Thorax ca. 3-fach hoeheren Strahlenexposition eine enge Indikationsstellung. Fragestellungen, die isoliert die Lungengefaesse, den Aortenbogen bzw. die deszendierende Aorta betreffen, koennen meist bereits mit einem Standard-CT-Datensatz beantwortet werden, fuer Pathologien der Aorta ascendens und zum Ausschluss einer koronaren Herzerkrankung (KHK) ist eine Submillimeterkollimation mit EKG-Synchronisation hingegen unerlaesslich. Erste Studienergebnisse

  8. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  9. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  10. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand

    International Nuclear Information System (INIS)

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  11. The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography - A systematic phantom study

    NARCIS (Netherlands)

    Groen, Jaap M.; Greuter, Marcel J.; Schmidt, Bernhard; Suess, Christoph; Vliegenthart, Rozemarijn; Oudkerk, Matthis

    2007-01-01

    Objective: The purpose of this study was to investigate the influence of heart rate, slice thickness, and calcification density on absolute value and variability of calcium score using 64-slice multidetector computed tomography (MDCT). Methods and Materials: Three artificial arteries containing each

  12. A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm

    NARCIS (Netherlands)

    Greuter, M. J. W.; Flohr, T.; van Ooijen, P. M. A.; Oudkerk, M.

    2007-01-01

    A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was ca

  13. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  14. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    Science.gov (United States)

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%. PMID:25675779

  15. [The role of multidetector computer tomography in diagnosis of acute pancreatitis].

    Science.gov (United States)

    Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M

    2014-10-01

    With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.

  16. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)]. E-mail: Sabbara@partners.org; Desai, Jay C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Butler, Javed [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Reddy, Vivek [Division of Cardiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2006-03-15

    A sizable portion of ventricular tachycardia circuits are epicardial, especially in patients with non-ischemic cardiomyopathy, e.g. Chagas disease. Thus there is a growing interest among the electrophysiologists in transepicardial mapping and myocardial ablation for treatment of arrhythmias. However, increased epicardial fat can be a significant hindrance in procedural success as it can mimic infarct during mapping and can also decrease the effectiveness of ablation. Quantitative knowledge of epicardial fat pre-procedure can potentially significantly facilitate the conduct and outcomes of these procedures. In this study we assessed the epicardial fat distribution and thickness in vivo in 59 patients who underwent multi-detector computed tomography (MDCT) for coronary artery assessment using a 16-slice scanner. Multiplanar reconstructions were obtained in the ventricular short axis at the basal, mid ventricular, and near the apex level, and in a four-chamber view. In the short axis slices, we measured epicardial fat diameter in nine segments, and in the four-chamber view, it was measured in five segments. In grooved segments the maximum fat thickness was recorded, while in non-grooved segments thickness at three equally spaced points were averaged. The results were as follows starting clockwise: superior inter-ventricular (IV) groove (all measurements are in mm, in basal, mid ventricular, and apical levels, respectively) (11.2, 8.6, 7.3), left ventricular (LV) superior lateral wall (1.0, 1.5, 1.7), LV inferior lateral wall (1.3, 2.2, 3.5), inferior IV groove (9.2, 6.5, 6.1), right ventricular (RV) diaphragmatic wall (1.4, 0.2, 1.0), acute margin (9.2, 7.3, 7.8), RV anterior free wall inferior (6.8, 4.0, 4.7), RV anterior free wall superior (6.5, 3.2, 3.1), RV superior wall (5.6, 2.7, 4.0), We measured the following four-chamber segments: LV apex (2.8 mm), left atrio-ventricular (AV) groove (12.7), right AV groove (14.8), RV apex (4.8), and anterior IV groove (7

  17. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation

    International Nuclear Information System (INIS)

    A sizable portion of ventricular tachycardia circuits are epicardial, especially in patients with non-ischemic cardiomyopathy, e.g. Chagas disease. Thus there is a growing interest among the electrophysiologists in transepicardial mapping and myocardial ablation for treatment of arrhythmias. However, increased epicardial fat can be a significant hindrance in procedural success as it can mimic infarct during mapping and can also decrease the effectiveness of ablation. Quantitative knowledge of epicardial fat pre-procedure can potentially significantly facilitate the conduct and outcomes of these procedures. In this study we assessed the epicardial fat distribution and thickness in vivo in 59 patients who underwent multi-detector computed tomography (MDCT) for coronary artery assessment using a 16-slice scanner. Multiplanar reconstructions were obtained in the ventricular short axis at the basal, mid ventricular, and near the apex level, and in a four-chamber view. In the short axis slices, we measured epicardial fat diameter in nine segments, and in the four-chamber view, it was measured in five segments. In grooved segments the maximum fat thickness was recorded, while in non-grooved segments thickness at three equally spaced points were averaged. The results were as follows starting clockwise: superior inter-ventricular (IV) groove (all measurements are in mm, in basal, mid ventricular, and apical levels, respectively) (11.2, 8.6, 7.3), left ventricular (LV) superior lateral wall (1.0, 1.5, 1.7), LV inferior lateral wall (1.3, 2.2, 3.5), inferior IV groove (9.2, 6.5, 6.1), right ventricular (RV) diaphragmatic wall (1.4, 0.2, 1.0), acute margin (9.2, 7.3, 7.8), RV anterior free wall inferior (6.8, 4.0, 4.7), RV anterior free wall superior (6.5, 3.2, 3.1), RV superior wall (5.6, 2.7, 4.0), We measured the following four-chamber segments: LV apex (2.8 mm), left atrio-ventricular (AV) groove (12.7), right AV groove (14.8), RV apex (4.8), and anterior IV groove (7

  18. Validation of a paediatric thyroid phantom using different multidetector computed tomography models

    Science.gov (United States)

    Alsabbagh, M.; Ng, L. Y.; Tajuddin, A. A.; Manap, M. A.; Zainon, R.

    2016-03-01

    The aim of this study was to compare the attenuation values of a fabricated paediatric thyroid phantom material using different MDCT models. A paediatric thyroid phantom was designed to mimic the shape and size of a paediatric patient with an age of 9 years using high- density Polyethylene as the phantom material. The fabricated phantom was scanned using two different multidetector CT scanners (16- and 128-row detectors). The CT numbers were evaluated and the mass attenuation coefficients (μ/ρ) of the phantom material were obtained at each applied energy from each scanner. The results were compared with the tables of the National Institute of Standards and Technology (NIST). The CTs of 16- and 128-row detectors showed that the obtained attenuation values are very similar to the NIST's values. However, the CT of the 128-row detectors showed a slightly much closer match to the NIST's values. This refers to the type and quality of the electronic connections between the detectors. Furthermore, the type and number of detectors (16- and 128-detectors) could affect the details and quality of the output images. The results show that different multidetector CTs can be used to validate the phantom and determine the mass attenuation coefficients of its material.

  19. Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

    International Nuclear Information System (INIS)

    Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (LungCARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4±5.9 years, 13 girls, 11 boys, 39.7±29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7±0.85 mm). The sensitivities were as follows: U1 95.8% and 100% with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k=0.6500) and without CAD very good (k=0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35-2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35-3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p=1.0) and noise/SNR. (orig.)

  20. Congenital varitans and anomalies of the pancreas and pancreatic duct: Imaging by magnetic resonance cholangiopancreaticography and multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Yener, Ouzlem [Dept. of Radiology, Tuerkiye Yueksek Ihtisas Hospital, Ankara (Turkmenistan); Erden, Aysel [Dept. of Radiology, Ankara University School of Medicine, Antalya (Turkmenistan); Tuerkoglu, Mehmet Akif [Dept. of General Surgery, Antalya University School of Medicine, Antalya (Turkmenistan)

    2013-12-15

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography.

  1. Multidetector computed tomography findings of mesenteroaxial gastric volvulus combined with torsion of wandering spleen: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Kyung; Ku, Young Mi; Lee, Su Lim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2016-05-15

    Gastric volvulus, defined as an abnormal rotation of stomach, may be idiopathic or secondary to abnormal fixation of intraperitoneal visceral ligaments. Wandering spleen is a movable spleen resulting from absence or underdevelopment of the splenic supporting ligaments that suspend the spleen to its normal position in the left part of the supramesocolic compartment of the abdomen. Wandering spleen increases the risk of splenic torsion. Both gastric volvulus and splenic torsion are potentially life-threatening if not urgently managed with surgery. Prompt and accurate diagnosis based on multidetector computed tomography (MDCT) is crucial to prevent unforeseen complications. Gastric volvulus and coexistent torsion of wandering spleen is a very rare condition. Herein, we described a case of gastric volvulus associated with wandering spleen and intestinal non-rotation in a 15-year-old girl focusing on MDCT findings.

  2. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. (orig.)

  3. [PROGNOSTIC VALUE OF SOME HEMOSTASIS-RELATED, HOMOCYSTEINE, HIGH SENSITIVE C R P AND MULTIDETECTOR COMPUTED TOMOGRAPHY PARAMETERS IN PULMONARY EMBOLISM].

    Science.gov (United States)

    Todua, F; Akhvlediani, M; Vorobiova, E; Baramidze, A; Tsivtsivadze, G; Gachechiladze, D

    2016-05-01

    Nowadays, an arsenal of diagnostic methods is used in diagnosis of pulmonary embolism, which includes x-ray, angiography, perfusion-ventilation scintigraphy, CT and magnetic resonance imaging, Doppler and laboratory studies. Purpose of our study was to evaluate the diagnostic significance of determination of some parameters of hemostasis (D-dimer, Soluble fibrinmonomer complexes, fibrinogen), homocysteine, hs-CRP and multidetector computed tomography in suspected pulmonary embolism. We have examined 54 patients -31 men and 23 women, aged 18 to 76 years, with characteristics of pulmonary embolism. According to our data, Multidetector computed tomography angiopulmonography , measuring D-dimer, fibrinogen and related hyperhomocysteinemia with increased level of hs-CRP may serve as binding, diagnostically significant laboratory markers in the diagnosis and treatment efficacy of pulmonary thromboembolism. PMID:27348165

  4. Multidetector computed tomography in abdominal emergencies; Multidetektor-CT bei abdominellen Notfaellen

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, N.; Schreyer, A.G. [Universitaetsklinikum Regensburg (Germany). Institut fuer Roentgendiagnostik

    2009-06-15

    Abdominal emergencies encompass traumatic events in the region of the abdomen as well as the clinical term acute abdomen. Multidetector CT (MDCT) represents one of the most important imaging modalities for detection and correct diagnosis in such abdominal emergencies. Based on the acquired data MDCT allows a stable imaging of the abdomen in an extremely short time even in critically ill patients. Multiplanar reconstructions can be created based on the high resolution data allowing an impressive visualization of the pathology. In this review article the most important abdominal pathologies of the abdomen diagnosed by MDCT are presented with special emphasis on the liver, bile ducts, spleen and kidneys as well as the gastro-intestinal tract. Additionally, MDCT imaging of the individual organ regions will be dealt with in detail. (orig.) [German] Abdominelle Notfaelle beinhalten sowohl traumatische Ereignisse im Bereich des Bauchraums als auch den klinischen Begriff des ''akuten Abdomens''. Die Darstellung solcher Notfaelle mittels Multidetektor-Computertomographie (MDCT) ist eine leistungsfaehige Methode zur Detektion und richtigen Diagnosefindung der abdominellen Notfaelle. Die MDCT erlaubt eine stabile Bildgebung des Abdomens in extrem kurzer Zeit bei schwerkranken Patienten und zudem multiplanare Rekonstruktionen, basierend auf den akquirierten Rohdatensaetzen mit der Moeglichkeit, zusaetzlich Befunde anschaulicher zu visualisieren. In diesem Uebersichtsartikel werden die MDCT-Charakteristika verschiedener abdomineller Notfaelle der wichtigsten Organregionen des Abdomens, wie der Leber und der Gallenwege, des Pankreas, der Milz und der Niere sowie des Gastrointestinaltrakts erlaeutert. Dabei wird speziell auf die Multidetektor-CT-Technik der einzelnen Organregionen eingegangen. (orig.)

  5. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    International Nuclear Information System (INIS)

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm3, 90.4%) than in calcified plaque (median, 0.7 mm3, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  6. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2013-12-15

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm{sup 3}, 90.4%) than in calcified plaque (median, 0.7 mm{sup 3}, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  7. Evaluation of the Pulmonary Veins and Left Atrial Volume using Multidetector Computed Tomography in Patients Undergoing Catheter Ablation for Atrial Fibrillation

    OpenAIRE

    Ito, Hiroki; Dajani, Khaled A.

    2009-01-01

    Catheter ablation is an evolving treatment option in patients with atrial fibrillation. Contrast enhanced electrocardiogram-gated multi-detector computed tomography (MDCT) has rapidly evolved over the past few years into an important tool in the diagnosis of coronary atherosclerosis. There is increasing recognition that MDCT is a useful tool to evaluate non-coronary structures, such as cardiac chambers, valves, the coronary sinus and adjacent structures including pulmonary veins. In particula...

  8. Relation of Pulmonary Function Impairment and Coronary Artery Calcification by Multi-detector Computed Tomography in Group Exposed to Inorganic Dusts

    OpenAIRE

    Lee, Won-Jeong; Shin, Jae Hoon; Park, So Young

    2013-01-01

    Background The purpose of this study was to evaluate the relationship of pulmonary function impairment (PFI) and coronary artery calcification (CAC) by multi-detector computed tomography (MDCT), and the effect of pneumoconiosis on CAC or PFI. Methods Seventy-six subjects exposed to inorganic dusts underwent coronary artery calcium scoring by MDCT, spirometry, laboratory tests, and a standardized questionnaire. CAC was quantified using a commercial software (Rapidia ver. 2.8), and all the subj...

  9. Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

    OpenAIRE

    Živorad N. Savić; Ivan I. Soldatović; Milan D. Brajović; Aleksandra M. Pavlović; Dušan R. Mladenović; Vesna D. Škodrić-Trifunović

    2011-01-01

    The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data wer...

  10. Evaluation of right ventricular function by 64-row CT in patients with chronic obstructive pulmonary disease and cor pulmonale

    International Nuclear Information System (INIS)

    Purpose: The aim of this study was to investigate the clinical application value of right ventricle (RV) function measured by 64 multi-detector row CT (MDCT) in patients with chronic obstructive pulmonary disease (COPD) and cor pulmonale. Materials and methods: Sixty-three consecutive patients with COPD and cor pulmonale were referred for electrocardiographically gated MDCT for evaluation of suspected or known coronary artery disease. Magnetic resonance imaging (MRI) for cardiac function analysis was performed on the same day. The MDCT and MRI examinations were successfully completed in 58 patients. Forty-six patients with COPD were divided into three groups according to the severity of disease by the pulmonary function test (PFT). Twelve patients diagnosed as cor pulmonale and 32 control subjects were also included. The RV function and myocardial mass (MM) were obtained by 64-MDCT and 1.5 T cardiac MRI in all of the groups. The results were compared among the groups using the Newman–Keuls method. Pearson's correlation was used to evaluate the relationship between the right ventricular ejection fraction (RVEF) and MM with the PFT results in COPD and cor pulmonale patients. Results: The RVEF was significantly lower in patients with severe COPD and cor pulmonale than it was in those patients with mild or moderate COPD (P < 0.01). There were strong correlations between MDCT and MRI (r = 0.826 for RV MM, r = 0.982 and 0.969 for RV EDV and RV ESV, r = 0.899 for RVEF) and between MDCT results and forced expiratory volume in 1 s (r = 0.787 for RVEF, r = −0.774 for RV MM) in all patients. Conclusion: MDCT can accurately quantify RV function and MM. The RVEF and RV MM measured by MDCT correlate well with the severity of disease as determined by PFT in patients with COPD and cor pulmonale. The assessment of right ventricular function is clinically important for evaluation of the severity of COPD, which may provide an objective basis for therapeutic strategy.

  11. Avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores Post-operative evaluation of endovascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Fabiana Barroso Thomaz

    2008-08-01

    Full Text Available OBJETIVO: Este estudo tem como objetivo a avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores. MATERIAIS E MÉTODOS: Foram analisadas, retrospectivamente, angiotomografias de 166 pacientes (137 homens e 29 mulheres com idade média de 73 anos portadores de aneurisma da aorta abdominal submetidos a terapêutica endovascular, no período de junho de 2005 a agosto de 2006. Os exames foram feitos em tomógrafo multidetector de 64 canais e os parâmetros adotados foram: colimação, 0,625 mm; pitch, 0,6-1; mAs, 300-400; kV, 120. Em todos os casos foi utilizado meio de contraste iodado não-iônico (350 mg/ml administrado por meio de bomba infusora, com fluxo de 4 ml/s a 5 ml/s e com volume variável de 70 ml a 100 ml. Os exames foram avaliados quanto à presença de complicações. RESULTADOS: Dos 166 exames realizados, 93 pacientes não apresentaram complicações e 73 apresentaram os seguintes achados: endoleak (n=37, trombose circunferencial da endoprótese (n=29, angulação (n=17, coleção no sítio de punção (n=10, migração da prótese (n=7, dissecção dos vasos de acesso (n=7 e oclusão (n=6. CONCLUSÃO: O endoleak foi a complicação mais prevalente em nosso estudo, sendo o tipo II o mais comum.OBJECTIVE: The present study was aimed at evaluating endovascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography. MATERIALS AND METHODS: Multidetector computed tomography angiography studies of 166 patients were retrospectively analyzed. The sample included 137 men and 29 women with mean age of 73 years who had undergone endovascular treatment for abdominal aortic aneurysm in the period between June 2005 and August 2006. Images were acquired in a 64-channel multidetector tomograph adopting the following parameters: 0.625 mm collimation, pitch 0.6-1, 300-400 mAs, and 120 kV. A nonionic iodinated contrast agent (350 mg/ml was injected

  12. Multidetector Computed Tomography Assessment in Biliary Atresia for the Diagnosis of Portosystemic Collaterals before Liver Transplant

    International Nuclear Information System (INIS)

    Introduction: Chronic liver disease increases portal vein pressure and modifies splanchnic circulation. This is particularly significant in infants with biliary atresia. Large collaterals steal portal flow and increase the risk of post transplant portal vein thrombosis. Objective: to describe different types of portosystemic collaterals prior to liver transplantation with low-dose multidetector CT (MDCT) in patients with biliary atresia. Material and methods: 13 patients with severe liver dysfunction due to biliary atresia underwent low-dose 64-MDCT before liver transplantation (effective tube current ranged from 20 to 120 mAs according to weight, with a kilo voltage of 80-120 for all CT). Hepatic arterial and portal venous phases were performed after IV contrast administration [1.5-2 ml/kg]. The mean age of the study group was1 year (range, 4 months to 3.6 years). Two radiologists reviewed the CT images to determine the grade and types of the portosystemic collaterals. Results: A total of 16 CT scans were obtained.the most common portosystemic collaterals found were esophageal (11), gastric submucosal (8), gastric adventitial (7, splenic (7), hemorrhoidal (10), mesenteric [dilated or tortuous branches of the inferior mesenteric vein (8)], retroperitoneal varices [gastro renal shunt (10), splenorenal shunt (4)] and dilated or tortuous left gastric vein (13). Conclusion: MDCT provides important information on venous system patency, presence of varices, and location of venous shunts in pediatric patients with biliary atresia going to liver transplant. in addition, it is critical to detect collaterals that are not evident on ultrasound in order to avoid the steal phenomenon that may lead to portal vein thrombosis and graft failure.

  13. Advanced Gastric Cancer and Perfusion Imaging Using a Multidetector Row Computed Tomography: Correlation with Prognostic Determinants

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Huan; Pan, Zilai; Du, Lianjun; Yan, Chao; Ding, Bei; Song, Qi; Ling, Huawei; Chen, Kemin [Jiaotong University, Jiaotong (China)

    2008-04-15

    Objective : To investigate the relationship between the perfusion CT features and the clinicopathologically determined prognostic factors in advanced gastric cancer cases. Materials and Methods : A perfusion CT was performed on 31 patients with gastric cancer one week before surgery using a 16-channel multi-detector CT (MDCT) instrument. The data were analyzed with commercially available software to calculate tumor blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS). The microvessel density (MVD), was evaluated by immunohistochemical staining of the surgical specimens with anti-CD34. All of the findings were analyzed prospectively and correlated with the clinicopathological findings, which included histological grading, presence of lymph node metastasis, serosal involvement, distant metastasis, tumor, node, metastasis (TNM) staging, and MVD. The statistical analyses used included the Student's t-test and the Spearman rank correlation were performed in SPSS 11.5. Result : The mean perfusion values and MVD for tumors were as follows: BF (48.14+/-16.46 ml/100 g/min), BV (6.70+/-2.95 ml/100 g), MTT (11.75+/-4.02 s), PS (14.17+/-5.23 ml/100 g/min) and MVD (41.7+/-11.53). Moreover, a significant difference in the PS values was found between patients with or without lymphatic involvement (p = 0.038), as well as with different histological grades (p 0.04) and TNM stagings (p = 0.026). However, BF, BV, MTT, and MVD of gastric cancer revealed no significant relationship with the clinicopathological findings described above (p > 0.05). Conclusion : The perfusion CT values of the permeable surface could serve as a useful prognostic indicator in patients with advanced gastric cancer.

  14. Thoracic Injuries in earthquake-related versus non-earthquake-related trauma patients: differentiation via Multi-detector Computed Tomography

    Directory of Open Access Journals (Sweden)

    Zhi-hui Dong

    2011-01-01

    Full Text Available PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT. METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR = 2.2; p<0.001. Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR=1.2; p<0.05 or flail chest (45/143 vs. 11/66 patients, RR=1.9; p<0.05 were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR= 1.7; p<0.01. Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR= 1.4; p<0.01. Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR=1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001. Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries.

  15. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  16. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    Directory of Open Access Journals (Sweden)

    Jong Gyu Kim

    2012-07-01

    Full Text Available Background During the planning of a thoracodorsal artery perforator (TDAP free flap,preoperative multidetector-row computed tomographic (MDCT angiography is valuablefor predicting the locations of perforators. However, CT-based perforator mapping of thethoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thickMDCT images in multiple planes to search for reliable perforators accurately.Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6females who underwent MDCT prior to TDAP free flap operations were enrolled in this study.Patients ranged in age from 10 to 75 years (mean, 39.3 years. MDCT images were acquired ata thickness of 1 mm in the axial, coronal, and sagittal planes.Results The thoracodorsal artery perforators were detected in all 19 cases. The reliableperforators originating from the descending branch were found in 14 cases, of which 6 hadtransverse branches. The former were well identified in the coronal view, and the latter in theaxial view. The location of the most reliable perforators on MDCT images corresponded wellwith the surgical findings.Conclusions Though MDCT has been widely used in performing the abdominal perforatorfree flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap.The results of this study suggest that multiple planes of MDCT may increase the probabilityof detecting the most reliable perforators, along with decreasing the probability of missingavailable vessels.

  17. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  18. Discordant findings of dimercaptosuccinic acid scintigraphy in children with multi-detector row computed tomography-proven acute pyelonephritis

    Directory of Open Access Journals (Sweden)

    Jeongmin Lee

    2011-05-01

    Full Text Available Purpose : The diagnosis of acute pyelonephritis (APN is often difficult, as its clinical and biological manifestations are non-specific in children. If not treated quickly and adequately, however, APN may cause irreversible renal damage, possibly leading to hypertension and chronic renal failure. We were suspecting the diagnostic value of 99mTc-dimercaptosuccinic acid (DMSA scan by experiences and so compared the results of DMSA scan to those of multi-detector row computed tomography (MDCT. Methods : We retrospectively selected and analyzed 81 patients who were diagnosed as APN by MDCT during evaluation of their acute abdomen in emergency room and then received DMSA scan also for the diagnostic work-up of APN after admission. We evaluated the results of imaging studies and compared the diagnostic value of each method by age groups, &lt;2 years (n=45 and ?#242; years (n=36. Results : Among total 81 patients with MDCT-proven APN, DMSA scan was diagnostic only in 55 children (68%, while the remaining 26 children (32% showed false negative normal findings. These 26 patients were predominantly male and most of them, 19 (73.1% were &lt;2 years of age. Conclusion : DMSA scan holds obvious limitation compared to MDCT in depicting acute inflammatory lesions of kidney in children with APN, especially in early childhood less than 2 years of age. MDCT showed hidden lesions of APN, those were undetectable through DMSA scan in children.

  19. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  20. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Catherine Yang

    2013-07-01

    Full Text Available Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications.

  1. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  2. Evaluation of lower-limb arteries with multidetector computed tomography angiography prior to free flap surgery: a radioanatomic study.

    Science.gov (United States)

    Tan, Onder; Yuce, Ihsan; Kantarci, Mecit; Algan, Said

    2011-03-01

    In this study, we aimed to evaluate the vascular structures of the lower limb with multidetector computed tomography (CT) angiography and to reveal the importance of this method in preoperative planning of microsurgical transplantation. In 24 patients, lower-limb arteries were bilaterally evaluated with 16-detector spiral CT scanner in terms of patency, stenosis, or occlusion; maximal and minimal external diameters through their traces; and variations as well as length of the peroneal artery. The peroneal artery was absent unilaterally in two patients (4.3%). The mean maximal and minimal diameters were as 2.77 and 1.63, 2.92 and 1.75, and 2.72 and 1.50 mm for anterior and posterior tibial and peroneal arteries, respectively. The ranges of lengths of peroneal arteries were 50 to 117 mm. This valuable tool can provide detailed information about vascular and the remaining anatomic structures by means of its high-resolution characteristics before planning free flap surgery. PMID:21181625

  3. Comparative study of earthquake-related and non-earthquake-related head traumas using multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Zhi-gang Chu

    2011-01-01

    Full Text Available OBJECTIVE: The features of earthquake-related head injuries may be different from those of injuries obtained in daily life because of differences in circumstances. We aim to compare the features of head traumas caused by the Sichuan earthquake with those of other common head traumas using multidetector computed tomography. METHODS: In total, 221 patients with earthquake-related head traumas (the earthquake group and 221 patients with other common head traumas (the non-earthquake group were enrolled in our study, and their computed tomographic findings were compared. We focused the differences between fractures and intracranial injuries and the relationships between extracranial and intracranial injuries. RESULTS: More earthquake-related cases had only extracranial soft tissue injuries (50.7% vs. 26.2%, RR=1.9, and fewer cases had intracranial injuries (17.2% vs. 50.7%, RR = 0.3 compared with the non-earthquake group. For patients with fractures and intracranial injuries, there were fewer cases with craniocerebral injuries in the earthquake group (60.6% vs. 77.9%, RR = 0.8, and the earthquake-injured patients had fewer fractures and intracranial injuries overall (1.5 + 0.9 vs. 2.5 +1.8; 1.3 + 0.5 vs. 2.1 + 1.1. Compared with the non-earthquake group, the incidences of soft tissue injuries and cranial fractures combined with intracranial injuries in the earthquake group were significantly lower (9.8% vs. 43.7%, RR = 0.2; 35.1% vs. 82.2%, RR = 0.4. CONCLUSION: As depicted with computed tomography, the severity of earthquake-related head traumas in survivors was milder, and isolated extracranial injuries were more common in earthquake-related head traumas than in non-earthquake-related injuries, which may have been the result of different injury causes, mechanisms and settings.

  4. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating

    International Nuclear Information System (INIS)

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale ( 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.)

  5. Myocardial bridging of the right coronary artery inside the right atrial myocardium identified by ECG-gated 64-slice multidetector computed tomography angiography.

    Science.gov (United States)

    Chen, Chien-Cheng; Chen, Huan-Wu; Fu, Chen-Ju; Lin, Fen-Chiung; Wen, Ming-Shien; Liu, Yuan-Chang

    2010-01-01

    A myocardial bridge (MB) is defined as an intramyocardial course of a major epicardial coronary artery, and it is mainly confined to the left ventricle and the left anterior descending coronary artery. There are rare reports of right coronary MB seen during angiographic examination. Herein, we present a 49 year-old man with right coronary artery MB without luminal narrowing in the diastolic and systolic phases of electrocardiography-gated computed tomography images. The value of multi-detector computed tomography for the detection of anatomical variants in the cardiovascular system is further discussed. PMID:20438676

  6. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  7. Accuracy of multidetector row computed tomography for the diagnosis of acute bowel ischemia in a non-selected study population

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, Walter [University Hospital Basel, Institute of Diagnostic Radiology, Basel (Switzerland); Clinic Stephanshorn, Medical Radiology Center, St. Gallen (Switzerland); Hauser, Andreas; Steinbrich, Wolfgang [University Hospital Basel, Institute of Diagnostic Radiology, Basel (Switzerland)

    2004-12-01

    The diagnostic accuracy of multidetector row computed tomography for the prospective diagnosis of acute bowel ischemia in the daily clinical routine was analyzed. Two hundred ninety-one consecutive patients with an acute or subacute abdomen, examined by MDCT over a time period of 5 months, were included in the study. All original CT diagnoses made during the daily routine by radiological generalists were compared to the final diagnoses made by using all available medical information from endoscopies, surgical interventions, autopsies and follow-up. Finally, all CT examinations of patients with an initial CT diagnosis or a final diagnosis of bowel ischemia were reread by a radiologist specialized in abdominal imaging in order to analyze the CT findings and the reasons for initially false negative or false positive CT readings. Twenty-four patients out of 291 (8.2%) had acute bowel ischemia. The age of affected patients ranged from 50 to 94 years (mean age: 75.7 years). Eleven patients were male, and 13 female. Reasons for acute bowel ischemia were: arterio-occlusive (n=11), non-occlusive (n=5), strangulation (n=2), over-distension (n=3) and radiation (n=3). The prospective sensitivity, specificity, PPV and NPV of MDCT for the diagnosis of acute bowel ischemia in the daily routine were 79.17, 98.51, 90.48 and 98.15%. MDCT reaches a similarly high sensitivity in diagnosing acute bowel as angiography. Furthermore, it has the advantage of being helpful in most of its clinical differential diagnoses and of being less invasive with the consecutive possibility of being used earlier in the diagnostic process with all the resulting positive effects on the patients prognosis. Therefore, nowadays MDCT should probably be used as the first step imaging modality of choice in patients with suspected acute bowel ischemia. (orig.)

  8. Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Lei [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Ma, Xiaohai, E-mail: maxi8238@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Feuchtner, Gudrun Maria [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria); Zhang, Chen; Fan, Zhanming [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China)

    2014-10-15

    Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as “dense” (areas with clear defined borders) or “diffuse” and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning.

  9. Predictive value of multi-detector computed tomography for accurate diagnosis of serous cystadenoma: Radiologic-pathologic correlation

    Institute of Scientific and Technical Information of China (English)

    Anjuli A Shah; Nisha I Sainani; Avinash Kambadakone Ramesh; Zarine K Shah; Vikram Deshpande; Peter F Hahn; Dushyant V Sahani

    2009-01-01

    AIM:To identify multi-detector computed tomography (MDCT) features mos t predi c t i ve of serous cystadenomas (SCAs),correlating with histopathology,and to study the impact of cyst size and MDCT technique on reader performance.METHODS:The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs.Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or ≥3 cm) and scanning protocols (dedicated vs routine).RESULTS:28/164 cysts (mean size,39 mm;range,8-92 mm) were diagnosed as SCA on pathology.The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28,78.6%),surface lobulations (25/28,89.3%) and central scar (9/28,32.4%).Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P=0.0001).The sensitivity,specificity and PPV of central scar and of combined microcystic appearance and lobulations were 32.4%/100%/100% and 68%/100%/100%,respectively.The reader confidence was higher for lesions>3 cm (P=0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P>0.05).CONCLUSION:Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs.Microcystic morphology is the most significant CT feature in diagnosis of SCA.A combination of microcystic appearance and surface lobulations offers accuracy comparable to central scar with higher sensitivity.

  10. Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography

    Institute of Scientific and Technical Information of China (English)

    Hamza Sunman; Giray Kabak; Lale Tokgzolu; Ali Oto; Kudret Aytemir; Hikmet Yorgun; Uur Canpolat; Ali Taher; Edis Demiri; Tuncay Hazrolan; Leventahiner; Ergn B.Kaya

    2014-01-01

    Background Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. Methods The patients were examined by using dual-source MDCT and conventional coronary angiography. MDCT results were analyzed with regard to the severity (>50%stenosis) and morphology (non-calcified, mixed, or calcified) of coronary atherosclerotic plaques evaluated in a 16-segment model. Results In total, 181 patients (94 men and 87 women) with 2,687 coronary artery segments were examined with MDCT. Ninety three patients were older than 65 years of age (group A, 42 men) and 88 were younger (group B, 52 men). Two-hundred nine coronary artery segments (7.2%) were ex-cluded because of small distal coronary vessel segments and/or motion artifacts. The overall number of segments with non-diagnostic image quality was similar in both groups of patients. Of the 2,687 evaluated segments, 157 (5.8%) were significantly diseased, and 144 of them were correctly detected by MDCT. Diagnostic evaluation showed that the sensitivity, positive predictive value, specificity, and negative pre-dictive value were 89.5%, 62.5%, 96.0%, and 99.2%, respectively in group A, and 95.2%, 64.8%, 97.5%, and 99.8%in group B, respectively. In addition, detailed segment-based analyses in coronary segments with non-calcified, mixed and calcified plaques in both groups were simi-lar diagnostic accuracy. Conclusions Very high diagnostic accuracy observed in this study suggests that MDCT coronary angiography could be a suitable diagnostic tool for not only younger patients but also for older patients.

  11. Study of radiation dose to the eye lens by multi-detector row computed tomography of the temporal bone

    International Nuclear Information System (INIS)

    The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone. (author)

  12. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  13. Multi-detector computed tomography in non-traumatic urologic emergencies; Multidetektor-CT bei nichttraumatischen urologischen Notfaellen

    Energy Technology Data Exchange (ETDEWEB)

    Scherr, M.K. [Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie

    2009-06-15

    Today's modern multi-detector computer tomography (MDCT) with its fast gantry rotation enables scanning of large body volumes with high temporal and spatial resolution. The fast acquisition of data and subsequent data reconstruction enables multiphase protocols with short time gaps between consecutive scan series so that large numbers of scans within one respiratory pause are possible and even in cases of non-cooperative patients acceptable quality of image data is provided. The acquired thin-slice raw data with isotropic submillimeter voxels can be visualized with different reconstruction algorithms. The aadvantages of imaging for diagnostics in urologic emergencies are the excellent visualization of acute arterial and venous pathologies, detailed assessment of renal parenchyma and the precise depiction of the urinary tract. In non-trauma settings this enables detailed visualization of inflammatory diseases and differentiation of obstructive or post-therapeutic pathologies along the upper and lower urinary tract. Based on these MDCT findings adequate therapy planning and planning of interventional or surgical procedures can be carried out. (orig.) [German] Durch den Einsatz moderner Multidetektor-Computertomographen (MDCT) mit schnellen Gantryrotationszeiten sind heute grosse Scanvolumina in hoher zeitlicher und mit hoher raeumlicher Aufloesung moeglich. Die schnelle Bilddatenakquisition und -verarbeitung ermoeglichen Mehrphasenprotokolle mit mehreren kurz aufeinander folgenden Scanserien innerhalb jeweils eines Atemanhalts und eine akzeptable Bildqualitaet bei unkooperativen Patienten. Diese fuehren zu duennschichtigen Rohdaten mit isotropen Voxel im Submillimeterbereich, die mit verschiedenen Nachrekonstruktionsverfahren optimal visualisiert werden koennen. Die urologische Notfalldiagnostik profitiert hier von der hervorragenden Darstellbarkeit akuter Gefaesspathologien in der arteriellen und venoesen Vaskularisation der Nieren. Die renale

  14. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    International Nuclear Information System (INIS)

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  15. Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

    International Nuclear Information System (INIS)

    Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as “dense” (areas with clear defined borders) or “diffuse” and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning

  16. Value of Multidetector Computed Tomography in Evaluation of Thoracic Venous Abnormalities among Pediatrics with Congenital Heart Disease

    Directory of Open Access Journals (Sweden)

    Dalia F Elbeih*, Mervat M El-Gohary *, Naglaa H Shebrya*,Mohammed A Saleh

    2013-04-01

    Full Text Available Introduction: Venous anomalies of the thorax can involve systemic or pulmonary veins and range from isolated incidental findings to components of more complex anomalies, most often congenital heart disease (CHD. Although echocardiography and catheter directed cardiac angiography are generally accepted as the primary imaging techniques for evaluation of CHD, CT and MRI are important complementary diagnostic tools. Multi-detector computed tomography (MDCT with its increasing availability and utility is now becoming a further method of imaging CHD. In light of its widespread availability, MDCT and 3D imaging are increasingly considered as a viable “one-stop shop” for preoperative imaging evaluation of cardiovascular structures in selected pediatric patients.Aim of the work: The aim of this work is to evaluate the role of MDCT in visualization of the thoracic venous system in pediatrics with congenital heart disease, show prevalence and types of venous anomalies and to compare this data with echocardiographic findings.Methods: The studied group included 30 cases referred to us by pediatric cardiologists to be examined by MSCT angiography of the heart and thoracic vessels. All the patients were known cases of congenital heart disease and underwent echocardiography. They were referred to answer specific anatomic question raised by inconclusive echocardiography, to assess suspected systemic and suspected pulmonary venous anomalies. All patients were subjected to full history taking, clinical examination and MDCT examination with CT lightspeed VCT XT 64-detectors row scanner (General Electric, Medical Systems, Milwaukee, Wisconsin, USA.Results: CTA findings had 77.8 % concordance with echocardiographic findings regarding SVC anomalies, 66.7 % concordance with echocardiography regarding IVC anomalies and 90 % concordance regarding pulmonary venous anomalies.Conclusion: Low dose protocol CTA is a promising method that complementary to Echocardioraphy

  17. Diagnostic performance of using effervescent powder for detection and grading of esophageal varices by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cansu, Aysegul, E-mail: drcansu@gmail.com [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Ahmetoglu, Ali; Kul, Sibel; Yukunc, Gokcen [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Fidan, Sami; Arslan, Mehmet [Department of Gastroenterology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Topbas, Murat [Department of Public Health, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey)

    2014-03-15

    Purpose: To investigate the effect of using effervescent powder (EP) on the efficacy of multi-detector computed tomography (MDCT) in detection and grading of esophageal varices in cirrhotic patients by considering endoscopy as the gold standard. Materials and methods: Ninety-two cirrhotic patients undergoing biphasic liver MDCT followed by upper gastrointestinal endoscopy within 4 weeks of MDCT were prospectively evaluated. The patients were divided into two groups before MDCT. The first group (n = 50) received effervescent powder (EP) before and during MDCT procedure and the second group did not receive (n = 42). The presence, size and grade of the esophageal varices were evaluated. MDCT findings were compared with endoscopic results. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of MDCT with EP and without EP were calculated and compared. Correlations between the grades of the varices for each group based on MDCT imaging and endoscopic grading were also evaluated. Results: The sensitivity, specificity, accuracy, PPV, and NPV of MDCT were 100%, 88%, 96%, 94%, and 100%, respectively, in the EP group, whereas they were 76%, 67%, 74%, 89%, and 43%, respectively, in the non-EP group. Correlations between the grades of the esophageal varices on MDCT and endoscopy were significant in both groups (r = 0.94, p < 0.001 for EP group and r = 0.70, p < 0.001 for non-EP group). Conclusion: During periodic CT scanning of cirrhotic patients, use of EP increases the success rate of MDCT for detection and grading of esophageal varices.

  18. Cuantificación del signo de la arteria cerebral media hiperdensa con TCMD Quantification of hyperdense middle cerebral artery sign by multidetector computed tomography (MDCT.

    Directory of Open Access Journals (Sweden)

    Francisco Meli

    2011-12-01

    CT scans with a 64-row multi-detector scanner (Brilliance 64; Philips Medical Systems. Absolute quantitative analysis was assessed by tracking tissue density of the MCA segment using region of interests. For relative quantification, density in the same segment of the contra- lateral MCA was measured to calculate the difference between both arteries. Results. In cases, mean density of affected MCA (62.5 HU, 99% CI: 46.2 - 78.7 was greater than that of the contra-lateral MCA segments (39.3 HU, 99% CI: 33.3-45.3 (p<0.0004 and also greater than that of controls (44.7 HU, 99% CI: 37.4-52 (p=0.0045. In relative quantification, the mean difference between density of the affected MCA and that of contra-lateral MCA in cases was 23.2 HU (95% CI: 11.7-34.7, while in controls the mean difference between the right MCA density and the left MCA density was 5.2 HU (95% CI: 2.4-8.4 (difference: 17.8 HU, p = 0.0062, 95% CI: 6.8-28.8. Conclusion. We showed significant (relative and absolute differences in MCA density in patients with suspected acute ischemic stroke as compared to normal subjects.

  19. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    International Nuclear Information System (INIS)

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  20. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  1. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M.

    2015-01-01

    Abstract To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner. We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy. The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences. Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  2. Comparison of Multidetector Computed Tomography and Flat-Panel Computed Tomography Regarding Visualization of Cortical Fractures, Cortical Defects, and Orthopedic Screws: A Phantom Study.

    Science.gov (United States)

    Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M

    2015-08-01

    To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting. PMID:26252281

  3. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    Energy Technology Data Exchange (ETDEWEB)

    Calisir, C.; Can, C.; Kebapci, M. [Dept. of Radiology and Dept. of Urology, Medical Faculty, Eskisehir Osmangazi Univ, Eskisehir (Turkey)

    2007-02-15

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis.

  4. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  5. Patterns of myocardial perfusion in humans evaluated with contrast-enhanced 320 multidetector computed tomography

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Linde, Jesper J; Fuchs, Andreas;

    2012-01-01

    of intravenous adenosine infusion on regional myocardial perfusion. To evaluate myocardial perfusion patterns at rest, we scanned 14 healthy subjects with PET and 14 age and gender matched subjects with 320 MDCT. To evaluate the effect of adenosine stress on relative perfusion patterns 14 subjects with near......Left ventricular (LV) myocardial contrast enhancement can be recorded using 320 multi detector computed tomography (MDCT). We aimed to (1) assess patterns of regional myocardial perfusion at rest and compare them with NH(3) positron emission tomography (PET) (2) and to assess the effect......-normal epicardial coronary arteries were studied at rest and during adenosine stress. Relative perfusion was assessed as attenuation density (AD) in 16 segments of the LV, and each segment was divided into 3 layers: endo-, mid- and epi-cardial. During rest the relative AD by MDCT was lower in the lateral wall...

  6. Effect of obesity on coronary artery plaque using 64 slice multidetector cardiac computed tomography angiography.

    Science.gov (United States)

    Isma'eel, Hussain; Tellalian, David; Hamirani, Yasmin S; Kadakia, Jigar; Nasir, Khurram; Budoff, Matthew J

    2010-04-30

    Patients with a coronary artery calcification score (CACS) of zero and an intermediate risk of coronary artery disease have been shown to have a low prevalence of non-calcified coronary artery plaque (NCP). 181 consecutive patients with CAC 'zero', undergoing cardiac computed tomography angiography (CCTA) angiography at our center were evaluated. Presence of detectable NCP on CCTA in these patients was 13.8%. Mild non-obstructive disease (50%). Traditional risk factors were not found to be associated with the presence of NCP. However higher body mass index (BMI) was strongly found to be associated with NCP (31.6 in patients with NCP vs. 27.6 kg/m(2) in patients without NCP, pNCP as compared to normal BMI (p<0.05).

  7. A radioanatomic study of the internal mammary artery and its perforators using multidetector computed tomography angiography.

    Science.gov (United States)

    Tan, Onder; Yuce, Ihsan; Aydin, Osman Enver; Kantarci, Mecit

    2014-05-01

    The Internal Mammary Artery (IMA) and its perforators play an important role in coronary bypass grafting and reconstructive breast, head, and neck surgery. This study aimed to obtain anatomic data pertaining to these vessels using Multi Detector Computed Tomography Angiography (MDCTA) and to demonstrate that the MDCTA could be a considerable assessment tool prior to surgery. In 50 outpatients (27 males and 23 females), the above-mentioned arteries were bilaterally evaluated with a 16-detector spiral computed tomography scanner. Based on the obtained images, diameters of the bilateral IMAs were separately measured in each intercostal spaces from 1 to 5 through their traces. IMAPs greater than 0.5 mm in diameter were bilaterally evaluated in terms of distance from the sternal border to the ramification point under the muscular layer, maximal external diameter at ramification from the IMA, and the length between the ramification point from the IMA and enter point to the subcutaneous fat tissue. Mean diameters of the left and right IMAs were 2.05 ± 0.50 mm and 2.20 ± 0.57 mm, respectively. Mean diameters, distances, and lengths of the perforators were 1.30 ± 0.30 mm, 6.80 ± 3.40 mm, 17.05 ± 6.07 mm on the left side and 1.32 ± 0.25 mm, 6.71 ± 3.43 mm, 17.35 ± 3.48 mm on the right side, respectively. No statistically difference was found between the sides (P > 0.05). About 20 of 36 perforators appeared in the second intercostal space, whereas there were eight in the first and eight in the third intercostal space. MDCTA, as a non-invasive vascular imaging method, can be a valuable tool for investigating the anatomic characteristics of the IMA and its perforators before planning an operation. PMID:24105707

  8. High-resolution computed tomography in patients with atypical 'cardiac' chest pain: a study investigating patients at 10-year cardiovascular risks defined by the Framingham and PROCAM scores

    Institute of Scientific and Technical Information of China (English)

    Choon Kiat ANG; Kui Hian SIM; Alan Yean Yip FONG; Sze Piaw CHIN; Tiong Kiam ONG; Seyfarth M Tobias; Wei Ling CHAN; Chee Khoon LIEW; Rapaee ANNUAR; Houng Bang LIEW

    2006-01-01

    Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary angiography. The latest 64-row multi-detector computed tomography (MDCT) technology is non-invasive, has high specificity and negative predictive values for the detection of significant coronary disease. Our aim was to investigate if this modality can provide more information in the assessment of outpatients with ACCP in addition to established cardiovascular risk scores. Methods Seventy consecutive patients presenting to the outpatient clinic with ACCP underwent 64-row MDCT scan of the coronary arteries. They were categorized into low, medium or high risk groups based upon the Framingham and PROCAM scores. We defined a clinically abnormal MDCT scan as coronary stenosis =50% or calcium score >400 Agatston. Results Fifty-three (75.7%) patients did not have clinically abnormal scans. Framingham score classified 43 patients as low-risk while PROCAM classified 59 patients as low-risk. MDCT scans were abnormal for 18.6% and 22.0% of the respective low-risk group of patients. For patients with medium-to-high risk, 33.3% and 36.4% of Framingham and PROCAM patient groups respectively had abnormal MDCT scans. Conclusion MDCT adds valuable information in the assessment of patients with ACCP by identifying a significant proportion of patients categorized as low-risk to have underlying significant coronary stenosis and coronary calcification by established cardiovascular risk scores.

  9. The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery.

    Science.gov (United States)

    Jeong, Hae Chang; Ahn, Youngkeun; Ko, Jum Suk; Lee, Min Goo; Sim, Doo Sun; Park, Keun Ho; Yoon, Nam Sik; Youn, Hyun Ju; Hong, Young Joon; Kim, Kye Hun; Park, Hyung Wook; Kim, Ju Han; Kim, Yun-Hyeon; Jeong, Myung Ho; Cho, Jeong Gwan; Park, Jong Chun; Kang, Jung Chaee

    2010-12-01

    Multi-detector computed tomography (MDCT) has been used for detecting or excluding coronary atherosclerotic stenosis in symptomatic patients. However, the role of MDCT for routine medical examination in asymptomatic, high-risk patients has not been established. We therefore conducted the present study to test the hypothesis that MDCT could be a valuable method for detecting subclinical coronary artery stenosis in asymptomatic patients. An observational, retrospective, single-centre study was conducted with a cohort of 1,529 patients (mean age, 56.4 ± 8.3 years; 1,353 males) who had undergone MDCT as part of their general medical checkups from November 2005 to April 2008. The patients who had a past history of coronary artery disease, typical chest pain, or evidence of myocardial ischemia were excluded. During clinical follow up of these patients, the incidence of subclinical coronary stenosis and the usefulness of MDCT for routine medical examination in asymptomatic patients were investigated. Of the 1,529 enrolled patients, 42.3% had hypertension, 13.5% had diabetes mellitus, 7.7% had hyperlipidemia, and 40.4% were current smokers. Abnormal MDCT findings were noted in 560 (36.6%) patients, who were classified into two groups. One group had the presence coronary calcium with a luminal diameter stenosis of the coronary artery of bridge, and 23 patients (1.5%) presented with significant stenosis. The patients with significant stenosis underwent percutaneous coronary intervention (PCI) with stent implantation. Major adverse cardiac events occurred in only 2 patients who had been treated with PCI during a mean follow-up period of 387 ± 253 days. The incidence of significant subclinical coronary stenosis as detected by MDCT in a general medical check-up was 3.4%, and the false-positive rate of MDCT for detecting significant coronary artery stenosis was 55.8% (29/52). 64-Slice MDCT can be a useful tool for noninvasive evaluation of coronary arteries in

  10. Prevalence of extracardiac findings in the evaluation of ischemic heart disease by multidetector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Jeong-Hwan Cho; Jong-Seon Park; Dong-Gu Shin; Young-Jo Kim; Sang-Hee Lee; Yoon-Jung Choi; Ihn-Ho Cho

    2013-01-01

    Objective Multidector computed tomography (MDCT) is now commonly used for the evaluation of coronary artery disease. Because MDCT images include many non-cardiac organs and the patient population evaluated is highly susceptible to extracardiac diseases, this study was designed to evaluate the prevalence of extracardiac findings in the MDCT evaluation of ischemic heart disease. Methods From March 2007 to March 2008, a total of six-hundred twenty patients, who underwent 64-slice MDCT evaluations for chest pain, or dyspnea, were enrolled in this study. Cardiac and non-cardiac findings were comprehensively evaluated by a radiologist. Results Enrolled patients included 306 men (49.4%), with a mean age of 66 years. Significant coronary artery stenosis was found in 41.6%of the patients. A total of 158 extracardiac findings were observed in 110 (17.7%) patients. Commonly involved extracardiac organs were lung (36.7%), hepatobiliary system (21.5%), thyroid (19.6%), kidney (10.8%), spine (9.7%) and breast (0.6%). Of those 110 patients, 50 (45.5%) patients underwent further diagnostic investigations. Malignant disease was detected in three (2.7%) patients (lung cancer, pancreatic cancer, and thyroid cancer). Conclusions Extracardiac findings are frequently present and should be a concern in the MDCT evaluation of chest pain syndrome.

  11. COMPARATIVE STUDY OF MULTIDETECTOR COMPUTED TOMOGRAPHY AND ULTRASONOGRAPHY FINDINGS IN BLUNT ABDOMINAL TRAUMA

    Directory of Open Access Journals (Sweden)

    Okram Pusparani Devi

    2016-07-01

    Full Text Available BACKGROUND Blunt abdominal trauma usually has low sensitivity on physical examination and also subtle clinical manifestations. Improved resolution of the ultrasound machines and availability of multiple frequency probes has improved the specificity of ultrasound evaluation in blunt abdominal trauma. Despite this about 50% of the solid organ injuries are missed. Computed tomography has been used with better specificity to evaluate patients with blunt abdominal trauma who are FAST (Focused Assessment with Sonography for Trauma positive as well as indeterminate and clinically suspicious cases of solid organ, hollow viscera, spine and pelvic injury. AIM AND OBJECTIVES The purpose of this study was to determine sensitivity, specificity and diagnostic accuracy of USG and MDCT and compare the efficacy of the two imaging modalities in blunt abdominal trauma. METHOD A prospective observational study of 100 patients was conducted in the Department of Radiodiagnosis, Bharati Hospital, Pune. All patients with blunt abdominal trauma were included. FAST screening was done with ANTARES ACUSON SIEMENS followed by MDCT on 16-Slice Philips Brilliance. Sensitivity, specificity and diagnostic accuracy of USG and CT were determined by comparing with laparotomy findings. RESULTS Although USG was sensitive, specific and accurate in detecting free fluid in abdomen, CT was found better and also superior in detecting solid organ injury in patients with blunt abdominal trauma. CONCLUSION Ultrasound is an efficient modality in the initial evaluation of blunt abdominal trauma. But CT is the superior diagnostic modality and must be performed in symptomatic patient with ultrasound negative report and suboptimal ultrasound examination. CT scan thoroughly scrutinizes entire abdomen including retroperitoneum with additional assessment of thoracic trauma and bony pelvic trauma. Hence, CT increases diagnostic confidence and influences management decision.

  12. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  13. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution : A cardiac phantom study

    NARCIS (Netherlands)

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-01-01

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative me

  14. Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, Thomas [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Wildermuth, Simon [Institute of Diagnostic Radiology, Kantonsspital St.Gallen (Switzerland)]. E-mail: Simon.Wildermuth@kssg.ch; Teodorovic, Ninoslav [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Mayer, Dieter [Division of Cardiovascular Surgery, University Hospital Zurich (Switzerland); Marincek, Borut [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Boehm, Thomas [Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland); Department of Medical Radiology, Institute of Diagnostic Radiology, Kantonsspital Chur (Switzerland)

    2007-01-15

    Anomalies of the vascular system are caused by false embryogenesis and are therefore present from birth. Single-detector row spiral computed tomography angiography (CTA) and multi-detector row computed tomography angiography (MDCTA) have gained increasing importance in the non-invasive assessment of vascular pathologies and replace conventional angiography in many cases. High-resolution volumetric datasets that are acquired during a single breath-hold give the possibility of two- (2D) and three-dimensional (3D)-post-processing. Due to post-processing, even complex vascular malformations are visualized in an understandable way. Furthermore, CTA, in contrast to conventional angiography, depicts not only the vascular structures but also allows assessment of the surrounding anatomical structures. We present cases of rare congenital anomalies of the thoracic vessels using MDCT with special respect to 2D- and 3D-post-processing.

  15. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  16. Endovascular treatment of thoracic aortic diseases: Follow-up and complications with multi-detector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)], E-mail: r.iezzi@rad.unich.it; Cotroneo, Antonio Raffaele; Marano, Riccardo; Filippone, Antonella; Storto, Maria Luigia [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2008-03-15

    Endovascular procedures with placement of stent-graft has become an accepted alternative to traditional open surgery for treatment of descending thoracic aortic aneurysms, ulcers, post-traumatic rupture, or complications of type-B dissection, due to significant reduction in perioperative mortality, rate of complications and length of hospitalization. Moreover, increasing operator experience and continuous advances in stent-graft technology are making treatment of a wider range of cases possible with redefinition of guidelines for endovascular stent-graft. The feasibility of endovascular stent-graft is mainly dependent on anatomic factors which represent the important predictors of the success of this procedure as well as on strictly follow-up in order to obtain early detection and treatment of eventual complications. Multi-detector CT-angiography is a fast, safe, and minimally invasive imaging technique that represents the standard of reference in the follow-up of patients who have undergone endovascular stent-graft, as it is effective and specific in the detection of procedure-correlated complications. The purpose of this article is to give a brief review of those techniques most commonly used for endovascular treatment of thoracic aortic diseases together with a more detailed description of post-procedural complications and their appearance on multi-detector CT-angiography.

  17. Value of cardiac 320-multidetector computed tomography and cardiac magnetic resonance imaging for assessment of myocardial perfusion defects in patients with known chronic ischemic heart disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Kühl, Jørgen T; Mathiasen, Anders B;

    2013-01-01

    The challenge for therapies targeting perfusion abnormalities is to identify and evaluate the region of interest. The aim of this study was to compare rest and stress myocardial perfusion measured by cardiac multi-detector computed tomography (MDCT) and cardiac magnetic resonance (CMR) imaging...... in patients with invasive coronary angiography demonstrated occluded vessels. Twenty-four patients with refractory angina due to occluded coronary arteries underwent perfusion imaging obtained by 320-MDCT scanner and 1.5 T MR scanner. Rest and adenosine stress images were obtained and interpreted using......) or 1 (abnormal). The summed rest and stress scores were calculated. MDCT and CMR had a high probability to identify perfusion defects. An excellent correlation between MDCT and CMR summed rest (r = 0.916) and stress scores (r = 0.915) was found. The interobserver reproducibility was high for MDCT...

  18. Imaging aid for thoracic surgery. Multidetector-row computed tomography evaluation of the tracheobronchial structure and bronchial tube selection for one-lung anesthesia

    International Nuclear Information System (INIS)

    The tracheobronchial structures were evaluated by multidetector-row computed tomography (MDCT), which provided imaging information for one-lung anesthesia during thoracic surgery. The subjects consisted of 100 patients. Three-dimensional (3D) images of the tracheobronchial structures and the bronchial tubes were created. Individual differences were found in the tracheobronchial structures in 100 patients. The length and the diameter of the right main bronchus were measured with 3D images and were not related to the patient's physical appearance, such as body height. Problematic intubation cases included a short right main bronchus <10 mm, an anomaly of the right bronchus, and tracheal stenosis. The 3D images demonstrated problematic areas of the tracheobronchial structure and helped the anesthesiologists select the most appropriate bronchial tube suitable for the tracheobronchial structure variations. Therefore, this technique is considered to contribute to safer performance of one-lung anesthesia. (author)

  19. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2015-05-01

    Full Text Available Objective The potential of computed tomography angiography (CTA was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours. Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2% based on both clinical grounds and imaging follow-up (stroke group, with statistically significant arterial stenosis and vulnerable plaques on CTA. Intracranial large artery disease was demonstrated in 34% of patients in the stroke group. Partial territorial infarct prevailed (86% while artery-to-artery embolization was the most common stroke mechanism (52%. Conclusion Multidetector CTA was useful for the etiologic work-up of hyperacute ischemic stroke and facilitated the knowledge about the topographic pattern of brain infarct in accordance with its causative mechanism.

  20. Efficacy of Multidetector-Row Computed Tomography as a Practical Tool in Comparison to Invasive Procedures for Visualization of the Biliary Obstruction

    Science.gov (United States)

    Taheri, Abdolmajid; Rostamzadeh, Ayoob; Gharib, Alireza; Fatehi, Daryoush

    2016-01-01

    Introduction: Recently, multidetector computed tomography (MDCT) has been introduced into clinical practice. MDCT has become the noninvasive diagnostic test of choice for detailed evaluation of biliary obstruction. Aim: the main objective of the present study was to evaluate the diagnostic value of MDCT compared to invasive procedures for detecting biliary obstruction causes. Material and Methods: Since February 2009 until May 2011 fifty biliary obstruction patients based on clinical, laboratory or ultrasonographic findings, were evaluated by Multidetector-row computed tomography. The causes of biliary obstruction, which was identified using. MDCT were classified into three categories: calculus, benign stricture, and malignancy. Final diagnosis was conducted based on percutaneous transhepatic cholangiography (PTC), endoscopic retrograde cholangiopancreatography, biopsy, or surgery. The MDCT diagnosis and were compared with the final diagnosis. Results: A correct diagnosis of causes of biliaryobstruction was made on the basis of MDCT findings for 44 of the total 50 patients. Two patients with chronic pancreatitis were incorrectly diagnosed with a pancreatic head adenocarcinoma on the basis of MDCT findings. One patient with biliary stone was incorrectly diagnosed with a periampullary adenocarcinoma on the basis of MDCT findings. The Sensitivity, specificity and accuracy of MDCT in the diagnosis of causes of biliary obstruction were 94.12% and87.87% and94.6% respectively. Conclusion: Based on the findings of this study MDCT has an excellent image quality, providing valuable information about the biliary tree and other abdominal organs. The use of advanced image processing, including maximum intensity projection and multiplanar reconstruction (especially coronal or sagittal reformatted images), allows superior visualization of the biliary tree and vascular structures. Three-dimensional reconstruction images complement axial images by providing a more anatomically

  1. Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT). Phantom and human studies

    International Nuclear Information System (INIS)

    Multi-detector row CT (MDCT) is a new noninvasive modality for coronary artery imaging. Using the same MDCT data obtained for coronary artery assessment, left ventricular (LV) volumes such as end-diastolic (ED) and end-systolic (ES) volumes (EDV and ESV, respectively) and ejection fraction (EF) can potentially be assessed when ED and ES datasets are extracted. The purpose of this study was to evaluate the feasibility of MDCT in the assessment of LV volumes. Using a pulsating heart phantom (EDV=143 ml, ESV=107 ml, stroke volume=36 ml, EF=25%) and MDCT, EDV and ESV were measured and EF was calculated. Clinical materials consisted of 11 consecutive human subjects who underwent MDCT. MDCT data were acquired during a single breathhold, using an intravenous injection of contrast medium. Left ventriculography (LVG) was performed in all patients as a gold standard. LV-EF was calculated by measuring ESV and EDV in all patients. In the phantom study, LV volumes were: EDV=137 ml, ESV=101 ml, stroke volume=36 ml, and EF=26%. Close correlations were observed between MDCT values and LVG values (EDV: r=0.95, ESV: r=0.98, EF: r=0.93, p<0.001). MDCT was useful for the assessment of LV volumes and EF in various patients with cardiovascular diseases (CVD). (author)

  2. The feasibility of axial and coronal combined imaging using multi-detector row computed tomography for the diagnosis and treatment of a primary spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Kim Do

    2011-05-01

    Full Text Available Abstract Background The preoperative detection of emphysema like changes (ELCs is necessary for the successful treatment of pneumothorax. High resolution computed tomography (HRCT has been used for the preoperative detection of ELCs. However, the traditional HRCT method uses only the axial view, which is perpendicular to the distribution of ELCs. This is not an ideal diagnostic method for the evaluation of ELCs. Methods Forty-eight patients with pneumothorax had multi-detector computed tomography (MDCT reconstruction using the coronal view. ELCs were evaluated in the axial and coronal view by a radiologist. A surgeon performed intra-operative examinations of the ELCs. The sensitivity of the different views was compared. Results The detection sensitivity was 74.4% (70/94 for the axial view and 91.5% (86/94 for the axial-coronal combined view. The intra-operative detection rate was 95.7% (90/94. The preoperative detection of ELCs on the axial-coronal combined view was significantly higher than on the conventional axial view alone (p Conclusions Evaluation of ELCs on the axial and coronal combined HRCT improved the sensitivity of preoperative detection of ELCs compared to the conventional single axial HRCT. This increased sensitivity will help decrease the recurrence with VATS.

  3. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    International Nuclear Information System (INIS)

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing

  4. Acute aortic syndromes: Role of multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca; Renda, Pietro [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy); Fiore, Davide [Department of Radiology, University of Padova, Padova (Italy); Scaglione, Mariano [Emergency and Trauma CT Section, Department of Radiology, Cardarelli Hospital, Naples (Italy); Piccoli, GianPiero [Cardiosurgery Division, Ospedali Riuniti ' Torrette-Lancisi-Salesi' , Ancona (Italy); Giovagnoni, Andrea [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy)], E-mail: a.giovagnoni@univpm.it

    2008-03-15

    Acute thoracic aortic syndromes encompass a spectrum of emergencies including aortic dissection, intramural haematoma, penetrating atherosclerotic ulcer and aneurysm rupture. All these life-threatening conditions require prompt diagnosis and appropriate management. To date multi-detector row Computed Tomography represents a valuable diagnostic tool especially in the emergency setting. This paper focus on the use of multi-detector row Computed Tomography in the evaluation of acute thoracic aortic syndromes and illustrates the key imaging findings related to each disease.

  5. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  6. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    International Nuclear Information System (INIS)

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1±2.4 preprocedural versus 18.6±2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2±0.2 versus 1.2±0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1±2.5 mm versus 16.5±2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  7. Right atrial volume calculated by multi-detector computed tomography. Useful predictor of atrial fibrillation recurrence after pulmonary vein catheter ablation

    International Nuclear Information System (INIS)

    We investigated whether right atrial (RA) volume could be used to predict the recurrence of atrial fibrillation (AF) after pulmonary vein catheter ablation (CA). We evaluated 65 patients with paroxysmal AF (mean age, 60+10 years, 81.5% male) and normal volunteers (57±14 years, 41.7% male). Sixty-four-slice multi-detector computed tomography was performed for left atrial (LA) and RA volume estimations before CA. The recurrence of AF was assessed for 6 months after the ablation. Both left and right atrial volumes were larger in the AF patients than the normal volunteers (LA: 99.7+33.2 ml vs. 59.7+17.4 ml; RA: 82.9+35.7 ml vs. 43.9+12 ml; P100 ml) for predicting the recurrence of AF was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 69.4% in 34 of 49 patients without recurrence. The sensitivity with large RA volumes (>87 ml) was 81.3% in 13 of 16 patients with AF recurrence, and the specificity was 75.5% in 37 of 49 patients without recurrence. RA volume is a useful predictor of the recurrence of AF, similar to LA volume. (author)

  8. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  9. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    International Nuclear Information System (INIS)

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  10. Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Yongdong Severance Hospital, Department of Radiology, Seoul (Korea); Ryu, Young Hoon; Hur, Jin; Kim, Sang Jin; Kim, Hyun Soo; Choi, Byoung Wook [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Young; Kim, Hyung Jung [Yonsei University College of Medicine, Department of Pulmonology, Seoul (Korea)

    2005-09-01

    The purposes of this study were to evaluate the right ventricular (RV) volume and mass using cardiac multidetector computed tomography (MDCT) and to compare the cardiac MDCT results with those from first-pass radionuclide angiography (FPRA). Twenty patients were evaluated for the RV end-diastolic volume (RVEDV), the RV end-systolic volume (RVESV), the RV ejection fraction (RVEF), and RV mass using cardiac MDCT with a two-phase reconstruction method based on ECG. The end-diastolic phase was reconstructed at the starting point of the QRS complex on ECG, and the end-systolic phase was reconstructed at the halfway point of the ascending T-wave on ECG. The RV mass was measured for the end-systole. The RVEF was also obtained by FPRA. The mean RVEF (47{+-}7%) measured by cardiac MDCT was well correlated with that (44{+-}6%) measured by FPRA (r=0.854). A significant difference in the mean RVEF was found between cardiac MDCT and FPRA (p=0.001), with an overestimation of 2.9{+-}5.3% by cardiac MDCT versus FPRA. The interobserver variability was 4.4% for the RVEDV, 6.8% for the RVESV, and 7.9% for the RV mass, respectively. Cardiac MDCT is relatively simple and allows the RV volume and mass to be assessed, and the RVEF obtained by cardiac MDCT correlates well with that measured by FPRA. (orig.)

  11. Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, Dagmar; Wildberger, Joachim E.; Das, Marco; Hohl, Christian; Mahnken, Andreas H.; Guenther, Rolf W.; Staatz, Gundula [University Hospital RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Barker, Michael [University Hospital RWTH Aachen, Department of Pediatrics, Aachen (Germany)

    2006-08-15

    To evaluate the value of dose-reduced 16-slice multidetector-row spiral computed tomography (16-MDCT) using virtual tracheobronchoscopy (VTB) and virtual bronchography (VBG) in children with suspected tracheobronchial stenosis. 12 children (4 d to 3 years, body weight 1.2 kg to 13.5 kg) with stridor and suspected tracheobronchial stenosis were examined by contrast-enhanced low-dose 16-MDCT. Conventional axial slices, MPRs, VTB, and VBG were calculated. Image findings were correlated with the results of fiberoptic bronchoscopy (12 out of 12) as a gold standard and subsequent surgery (8 out of 12). VTB and VBG demonstrated the fiberoptic bronchoscopically suspected tracheal stenosis in 11 of 12 children due to vascular compression because of the brachiocephalic trunk (6), a double aortic arch (2), a vascular compression of the left main bronchus (2), and a right aberrant subclavian artery (1). Eleven out of 12 stenoses were correctly depicted by conventional axial slices, MPRs, VTB, and VBG. Dose reduction was 79 to 85.8% compared to a standard adult chest CT. Dose-reduced 16-MDCT with the use of VTB and VBG is effective for the evaluation of tracheobronchial stenosis in children and correlates well with fiberoptic bronchoscopy. (orig.)

  12. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    International Nuclear Information System (INIS)

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  13. Magnetic Resonance Enterography Findings in Crohn′s disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques

    Directory of Open Access Journals (Sweden)

    Parul Patel

    2011-01-01

    Full Text Available Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD in pediatric populations. With the advent of multidetector computed tomography (MDCT, it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well as demonstrate extra-enteric complications of IBD such as abscesses, fistulae, and sinus tracts. The major disadvantage of CT however is exposure to ionizing radiation, especially in IBD patients of the pediatric age group who maybe repeatedly imaged due to exacerbations. As a result, magnetic resonance enterography (MRE is becoming increasingly important in the evaluation and follow-up of pediatric patients with IBD. This pictorial essay will summarize the multi-modality imaging findings of IBD with emphasis on MRE including the imaging protocol and procedure. For the purposes of this article, patients less than 17 years of age have been considered to represent the pediatric population.

  14. Evaluation of pulmonary artery branching patterns in the right upper lobe of the lung from multiplanar reconstruction images using multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Multidetector-row computed tomography (MDCT) allows the high resolution multi-planar reconstruction (MPR) of images taken in the coronal, sagittal and axial planes. The purpose of this study was to evaluate the branching patterns of the A3a pulmonary artery in the right upper lobe from MPR images, and to assess the MDCT protocol and analysis method. The 32 cases studied comprised 30 patients with known or suspected disease of the lung parenchyma and 2 healthy volunteers. An MDCT scanner, Aquilion (Toshiba, Tokyo, Japan), was used for pulmonary imaging. Coronal and sagittal images were reconstructed from the axial scans at 2-mm intervals. The arterial variations of A3ai and A3aii, arising from either the superior trunk or the ascending artery (a branch of the inferior trunk) were evaluated. A3ai was found to originate from the superior trunk in 31 subjects (96.9%) and from the ascending artery in one subject (3.1%), whereas A3aii originated from the superior trunk in 12 subjects (62.5%) and from the ascending artery in 12 (37.5%). High resolution MPR images can provide a means of assessing the arterial branching pattern at the level of the sub-segmental pulmonary artery. (author)

  15. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    International Nuclear Information System (INIS)

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  16. Non-obstructive low attenuation coronary plaque predicts three-year acute coronary syndrome events in patients with hypertension. Multidetector computed tomographic study

    International Nuclear Information System (INIS)

    Arterial hypertension is an established risk factor for acute coronary syndrome (ACS). Multidetector computed tomography (MDCT) is an accurate and less invasive technique for assessment of the degree of coronary artery luminal narrowing and characterization of coronary atherosclerosis. We therefore aimed to investigate the predictive power of MDCT for future ACS events and compared with traditional parameters in patients with hypertension. One hundred and thirty-four patients (93 men, mean age 70±11 years) with hypertension underwent MDCT for evaluation of coronary artery disease. MDCT analysis focused on the presence of plaques, the degree of stenosis, and the plaque characteristics. Traditional parameters included Framingham risk score, carotid intima-media thickness, and left ventricular mass index. During a mean follow-up of 39±10 months, ACS events occurred in 10 patients, including myocardial infarction (n=3) and unstable angina (n=7). Multivariate analysis identified total number of low attenuation plaques as an independent predictor of ACS events (p<0.001). We demonstrated that non-obstructive low attenuation coronary plaques on MDCT predicted more accurately future ACS events in patients with hypertension than traditional parameters. (author)

  17. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 {+-} 2% and 66.2 {+-} 3% in stage I, 53.5 {+-} 11% and 52 {+-} 6% in stage II, and 32.3 {+-} 7% and 44.2% {+-} 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant ({rho} < 0.01, {rho} < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema.

  18. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV1.0%) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  19. A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Greuter, M.J.W.; Ooijen, P.M.A. van; Oudkerk, M. [University Medical Center Groningen, University of Groningen, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Flohr, T. [Siemens Medical Solutions, CT Division, Forchheim (Germany)

    2007-03-15

    A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was calculated for heart rates between 50 and 100 bpm for rotation times of 420, 370, and 330 ms, and one-, two-, three-, and four-sector acquisition modes and irregular coronary artery movement is included. The model predicts optimal timing within the RR cycle of 45{+-}3% (RCA), 44{+-}4% and 74{+-}6% (LCX), and 35{+-}4% and 76{+-}5% (LAD). The optimal timing shows a negative linear dependency on heart rate and increases with the number of sectors used. The RCA blurring decreases from 0.98 cm for 420 ms, one-sector mode to 0.27 cm for 330 ms, four-sector mode. The corresponding values are 0.81 cm and 0.29 cm for LCX and 0.42 cm and 0.17 cm for LAD. The number of sectors used in a multisector reconstruction and the timing within the cardiac cycle should be adjusted to the specific coronary artery that has to be imaged. Irregular coronary artery movement of 1.5 mm justifies the statement that no more than two sectors should be used in multisector acquisition processes in order to improve temporal resolution in cardiac MDCT. (orig.)

  20. Comparison of MDCTA (16-slice multi-detector row computed tomography arthrography) and MRA (magnetic resonance arthrography) for detecting labral lesions of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung A; Cha, Jang Gyu; Hong, Hyun Sook; Choi, Deuk Lin; Park, Jai Soung; Lee, Hae Kyung; Kim, Dae Ho [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2007-11-15

    To compare the accuracy of 16-slice multi-detector row computed tomographic arthrography (MDCTA) and magnetic resonance arthrography (MRA) for making the diagnosis and classification of labroligamentous injuries. This study is a prospective series that used MRA and MDCTA to examine 23 patients who complained of shoulder instability. Two radiologists independently analyzed the MRA and MDCTA. The sensitivity, specificity, accuracy, positive and negative predictive values were calculated from the arthrograms and the arthroscopic findings. The images of MDCTA and MRA corresponded with the findings on arthroscopy. Both imaging modalities had the same sensitivity for detecting Bankart lesions (n = 10, 90%) and posterior labral tears (n = 2, 50%) on McNemar test ({rho} = 1.00). For superior labrum anterior-to-posterior (SLAP) lesions, 6 MRA cases and 4 MDCTA cases corresponded with the arthroscopic findings. The difference between the sensitivities of MDCTA (66.7%) and MRA (100%) was not significant ({rho} 0.09). We suggest that the sensitivity of diagnosing labral lesions that induce shoulder instability is similar for MDCTA and MRA. MDCTA is effective for diagnosing and evaluating shoulder instability.

  1. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT)

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Chenggong; Tan, Xiangliang; Li, Caixia; Wu, Yuankui; Hao, Peng; Xiong, Wei; Xu, Yikai [Southern Medical University, Department of Medical Imaging Center, Nanfang Hospital, Guangzhou, Guangdong (China); Wei, Qi; Feng, Ru; Xu, Jun [Southern Medical University, Department of Hematology, Nanfang Hospital, Guangzhou (China); Chan, Queenie [Philips Healthcare, New Territories (China)

    2014-09-18

    To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5 % and 86.9 %, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. (orig.)

  2. Clinical and prognostic significance of bone marrow abnormalities in the appendicular skeleton detected by low-dose whole-body multidetector computed tomography in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Clinical significance of medullary abnormalities in the appendicular skeleton (AS) detected by low-dose whole-body multidetector computed tomography (MDCT) in patients with multiple myeloma (MM) was investigated. A total of 172 patients with monoclonal gammopathy of undetermined significance (MGUS) (n=17), smoldering MM (n=47) and symptomatic MM (n=108) underwent low-dose MDCT. CT values (CTv) of medullary density of AS⩾0 Hounsfield unit (HU) was considered as abnormal. Percentage of medullary abnormalities and the mean CTv of AS in patients with MGUS, smoldering MM and symptomatic MM were 18, 55 and 62% and −44.5 , −20.3 and 11.2 HU, respectively (P<0.001 and P<0.001). Disease progression of MM was independently associated with high CTv on multivariate analysis. In symptomatic MM, the presence of abnormal medullary lesions was associated with increased incidence of high-risk cytogenetic abnormalities (34.4% vs 7.7% P=0.002) and extramedullary disease (10.4% vs 0% P=0.032). It was also an independent poor prognostic predictor (hazard ratio 3.546, P=0.04). This study showed that CTv of AS by MDCT is correlated with disease progression of MM, and the presence of abnormal medullary lesions is a predictor for poor survival

  3. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation

    International Nuclear Information System (INIS)

    In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI. A total of 122 patients (67 male, mean age 84 ± 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated. Mean eccentricity of the aortic annulus determined by MDCT was 0.34 ± 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 ± 2.1 mm in MDCT and 24.0 ± 2.5 mm in TEE (P < 0.0001 for agreement). Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. (orig.)

  4. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  5. Xenon/CT blood flow mapping of the liver using multidetector-row computed tomography. Compensation of respiratory misregistration by volume data

    International Nuclear Information System (INIS)

    For improvement in the accuracy of xenon/CT blood flow mapping of the liver, this study was conducted to assess whether volume-data obtained by multidetector-row helical CT could compensate for the slice misregistration caused by inconstant breath depth. Using imaging phantoms scanned on both multidetector-row and single-detector CT, suitable parameters were decided. In the phantom studies, axial scan with multidetector-row CT showed significantly greater variance of CT value than that of single detector row CT (SDCT). On multidetector-row CT, variances of the CT values maintained in low (80 kV) tube voltage, which is advantageous for detecting subtle enhancement of the liver. Images reconstructed with 10-mm thickness showed smaller variance than those of 5-mm thickness on low-pitch helical scan. Remarkable helical artifacts were seen on the high-pitch helical scan. Following the phantom studies, 7 examinees were scanned using xenon/CT with a predetermined scan protocol (80 kV, collimation 5 mm, thickness 10 mm, low-pitch helical scan). In all cases, slice compensation was necessary and was successfully performed. The number of pixels which constituted blood flow map increased after the compensation. No patients showed any significant adverse effects. In conclusion, multidetector-row helical CT has the potential for providing accurate quantification of xenon/CT blood flow mapping of liver by compensating for respiratory misregistration. (author)

  6. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  7. Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, Fredrik [Lund University, Department of Radiology, Malmoe University Hospital, 205 02, Malmoe (Sweden); Nyman, Ulf [Lund University, Department of Radiology, Lasarettet Trelleborg, 23185, Trelleborg (Sweden)

    2006-05-15

    The aim of this study was to assess the feasibility of minimising contrast-medium (CM) doses using 80-peak kilovoltage (kVp) 16-channel multidetector computed tomography (MDCT) with CM dose tailored to body weight, when diagnosing pulmonary embolism (PE) in azotaemic patients. Twenty-nine patients (68-93 years; 38-79 kg) with an estimated glomerular filtration rate of 12-49 ml/min underwent 80 kVp MDCT at a median dose of 200 mg iodine (I)/kg and 15 s injection time. Pulmonary artery (PA) enhancement where compared with our own reference material using 320 mg I/kg at 120 kVp and with reported figures in the literature at 120-140 kVp and a 42 g iodine CM dose. Median (1st and 3rd quartiles) values regarding CM dose were 12.2 (9.9-12.8) g iodine; density of left main and lower lobe segmental PA 339 (275-395) Hounsfield units (HU) and 354 (321-442) HU, respectively. Those enhancement values were similar to those obtained from the reference population at 120 kVp and those reported in the literature at 120-140 kVp. One patient had a transient increase in plasma creatinine. Three months' follow-up revealed deep venous thrombosis among 1/18 patients with negative results from computed tomography (CT). We conclude that 80 kVp 16-channel MDCT to diagnose PE in azotaemic patients may be performed with markedly reduced CM doses, implying a lesser risk for CM-induced nephropathy. (orig.)

  8. 经胃镜胃黏膜下注射64排螺旋CT胃周淋巴结造影初探%Lymphatic Drainage from Gastric Tract:Preliminary Investigating Feasibility of Endoscopic 64-row Spiral CT Lymphography

    Institute of Scientific and Technical Information of China (English)

    朱建兵; 陈光强; 李勇; 朱江涛; 张伟; 龚建平

    2012-01-01

    目的 初步探讨胃黏膜下注射64排螺旋CT胃周淋巴结造影的应用价值.方法 征集21例志愿患者,进行胃镜下胃黏膜下造影剂注射,然后进行64排螺旋CT扫描.结果 16例患者均在完成64排螺旋CT的扫描获得相应图像.CT图像显示5例患者可见肝脏及血管旁线性致密影呈现;14例非胃癌患者仅8例发现可辨别的淋巴结影,其中2例患者发现胃周淋巴结密度增高.结论 胃镜辅助下64排螺旋CT胃周淋巴结造影作为一种潜在的术前淋巴结造影的选择具有一定优越性,但是应用于临床需要进一步的研究.%Objective To investigate feasibility of endoscopic 64-row spiral CT lymphography of the gastric tract preliminarily.Methods With institutional committee approval,a total of 2mL of undiluted iopamidol was injected into the gastric submucosa by endoscope in 21 volunteer patients,then scanning with 64-row spiral CT. Result 16 patients completed CT scan and got the imaging needed;5 patients were found the line high attenuation nearby liver and vascular;8 of the 14 patients were found lymphatic nodes identified;2 patients were found high attenuation lymphatic nodes nearby stomach.Conclusion Endoscopic 64-row spiral CT lymphography of stomach as a potentially lymphography of the stomach,still needs more investigation for clinic application.

  9. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    A Chatterjee; Sushil Kamerkar; A K Jethra; S Padmini; M P Diwakar; S S Pande; M D Ghodgaonkar

    2001-07-01

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

  10. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chen Tianwu, E-mail: twchenscu@yahoo.com.cn [Sichuan Province Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637000 (China); Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yang Zhigang, E-mail: yangzg6666@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Dong Zhihui, E-mail: dongzhih@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li Yuan, E-mail: dr.liyuan@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yao Jin, E-mail: shelleyyao@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Wang Qiling, E-mail: xiaohongmao99@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Qian Lingling, E-mail: moneylinglingch1999@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2011-11-15

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 {+-} 0.49 whereas S/N ratios were 5.21 {+-} 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 {+-} 24.15 ml/min/ml, 24.06 {+-} 9.87 HU, 29.42 {+-} 8.61 s, and 12.45 {+-} 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  11. Noninvasive Multidetector Computed Tomography Enterography in Patients with Small-Bowel Crohn's Disease: Is a 40-Second Delay Better than 70 Seconds?

    International Nuclear Information System (INIS)

    Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established. Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography. Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n 10). Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader. Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material

  12. Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiao-chun; YANG Zhi-gang; GUO Yin-kun; ZHANG Rui-ming; WANG Jian; ZHOU Dai-quan; CHENG Lin; CHEN Lin

    2012-01-01

    Background Right ventricular (RV) dysfunction ensues due to rheumatic mitral stenosis (RMS).The evaluation of RV function is clinically important for the diagnosis,treatment,and follow-up for patients with different degrees of RMS.Thepurpose of this study was to determine whether the 64-slice multi-detector row computed tomography (64-slice MDCT)can assess the RV function in RMS with high accuracy and reproducibility when compared to MR imaging (MRI).Methods Right ventricular end-diastolic and end-systolic volumes (RV-EDV and RV-ESV),stroke volume (RV-SV),ejection fraction (RV-EF),cardiac output (RV-CO),and wall mass (RV-Mass) were measured with dedicated cardiac analysis software on 64-slice MDCT and compared with values measured with MRI in 43 consecutive patients with RMS.Agreement between MRI and 64-MDCT results were compared with Bland and Altman analysis and linear regression analysis.Repeated measurements were performed to determine intraobserver and interobserver variability.Results No significant differences were revealed in calculated RV function parameters between the two methods.RV-EDV,RV-ESV,RV-SV,RV-EF,RV-CO,and RV-Mass by 64-slice MDCT were similar to those by MRI (P>0.05).There were good correlations (r=0.98,0.97,0.96,0.96,0.95 and 0.77,respectively) and close agreement (bias=-0.2 ml,-1.0ml,0.8 ml,0.5%,26.1 ml,and 0.5 g,respectively,P>0.05).The variability in 64-slice MDCT measurements was similar to that in MRI values.Conclusion ECG-gated 64-slice MDCT could assess the RV function in RMS with high accuracy and reproducibility when compared to MRI.

  13. Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Aim: To assess the effect of two iterative reconstruction algorithms (AIDR and AIDR3D) and individualized automatic tube current selection on radiation dose and image quality in computed tomography coronary angiography (CTCA). Materials and methods: In a single-centre cohort study, 942 patients underwent electrocardiogram-gated CTCA using a 320-multidetector CT system. Images from group 1 (n = 228) were reconstructed with a filtered back projection algorithm (Quantum Denoising Software, QDS+). Iterative reconstruction was used for group 2 (AIDR, n = 379) and group 3 (AIDR3D, n = 335). Tube current was selected based on body mass index (BMI) for groups 1 and 2, and selected automatically based on scout image attenuation for group 3. Subjective image quality was graded on a four-point scale (1 = excellent, 4 = non-diagnostic). Results: There were no differences in age (p = 0.975), body mass index (p = 0.435), or heart rate (p = 0.746) between the groups. Image quality improved with iterative reconstruction and automatic tube current selection [1.3 (95% confidence intervals (CI): 1.2–1.4), 1.2 (1.1–1.2) and 1.1 (1–1.2) respectively; p < 0.001] and radiation dose decreased [274 (260–290), 242 (230–253) and 168 (156–180) mGy cm, respectively; p < 0.001]. Conclusion: The application of the latest iterative reconstruction algorithm and individualized automatic tube current selection can substantially reduce radiation dose whilst improving image quality in CTCA

  14. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  15. Diagnostic Sensitivity of Multidetector-Row Spiral Computed Tomography Angiography in the Evaluation of Type-II Endoleaks and their Source: Comparison between Axial Scans and Reformatting Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Pascalis, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G. (Depts. of Radiology and Vascular Surgery, Azienda Ospedaliero-Universitaria di Cagliari, Polo di Monserrato, Monserrato, Cagliari (Italy))

    2008-07-15

    Background: After endovascular stent-graft placement, several complications may occur. Retrograde filling of the aneurysm (type-II endoleak) is the most common. Purpose: To evaluate the accuracy, image quality, and interobserver agreement of multidetector-row spiral computed tomography angiography (MDCTA) in the diagnosis of type-II endoleak, by using various types of reformatting techniques in comparison to regular axial images. Material and Methods: Twenty-four patients who had had endovascular repair of an infrarenal abdominal aortic aneurysm with stent graft were retrospectively studied. In 12 of 24 patients, a type-II endoleak was found. CT scans were obtained after intravenous administration of 130 ml of nonionic contrast material using a 4-6-ml/s flow rate. All patients were investigated with axial scans, multiplanar reconstruction (MPR), maximum intensity projection (MIP), shaded-surface display (SSD), and volume-rendering (VR) techniques. For each patient and for each reconstruction method, the image quality of the scans was scored as 0 for bad quality, 1 for poor quality, 2 for good quality, and 3 for excellent quality images. Two radiologists reviewed the CT images independently. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each reconstruction method, with the axial images as the reference method. Interobserver agreement and kappa value were also recorded. Results: MPR showed the highest sensitivity (83% and 67% for observers 1 and 2, respectively), PPV (91% and 80% for observers 1 and 2, respectively), and NPV (85% and 71% for observers 1 and 2, respectively), whereas VR showed the highest specificity (92% for both observer 1 and 2). Conclusion: Reformatting techniques provide good-quality images; nevertheless, their efficacy in the study of type-II endoleak was found to be suboptimal in comparison to regular axial images. The MPR technique is probably the best choice in conjunction

  16. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  17. Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing

    International Nuclear Information System (INIS)

    Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 ± 5 years, mean heart rate 54 ± 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 ± 3.8 mm2 and -0.2 ± 2.2 mm2 (p 2, respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area

  18. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  19. Multi-detector computer tomography venography (MDCTV as a diagnostic tool in the management of patients with atypical, complicated and/or recurrent varicose veins

    Directory of Open Access Journals (Sweden)

    Andrew Lawson

    2012-12-01

    Full Text Available Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV, compared with conventional venography, as a diagnostic tool in the management of patients with atypical, complicated and/or recurrent varicose veins. Materials and methods. Retrospective review of 21 patients who had undergone both MDCTV and conventional transfemoral or transpopliteal venography between January 2008 and April 2011 for the management of recurrent varicose veins and/or chronic venous ulcers. MDCTV was performed using a 16-slice CT scanner. Spiral acquisition was commenced 180 seconds after intravenous injection of 150 ml of 350 mmol/l iodinated contrast medium. A reconstruction interval of 1.5 mm was used. Conventional venography was performed by the resident vascular surgeon and was followed by stenting or coiling where appropriate. Results. MDCTV and venography were compared in 21 patients (6 male, 15 female; average age 55 years, range 33 - 78 years; 8 also underwent endovascular iliac vein stenting. The area under the receiver operator curve (ROC for percentage iliac vein stenosis determined on MDCTV versus venography was 0.75. Four (19% false-positive iliac vein stenoses were reported on MDCTV. Ten patients underwent gonadal vein coil embolisation. Gonadal vein size >5.2 mm (range 1 - 11 mm on MDCTV predicted significant venographic reflux requiring coil embolisation. Three (30% patients who underwent embolisation did not have gonadal vein enlargement on MDCTV. Conclusion. MDCTV plays an important adjunctive role in the diagnostic workup of patients with complex venous disease. The findings at MDCTV correlate well with conventional venography.

  20. Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

    Directory of Open Access Journals (Sweden)

    Živorad N. Savić

    2011-01-01

    Full Text Available The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA in measuring carotid artery wall thickness (CAWT and color Doppler ultrasound (CD-US in measuring intimae-media thickness (IMT. Eighty-nine patients (aged 35–81 were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test, and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01. We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US.

  1. Morphometric evaluation of bony nasolacrimal canal in a caucasian population with primary acquired nasolacrimal duct obstruction: A multidetector computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Bulbul, Erdogan; Yazici, Alper; Yanik, Bahar; Yazici, Hasmet; Demirpolat, Gulen [Balikesir University School of Medicine, Balikesir (Turkmenistan)

    2016-04-15

    The bony nasolacrimal duct (BNLD) morphology as a contributory factor in primary acquired nasolacrimal duct obstruction (PANDO) is still controversial. The objectives of this study were to evaluate the morphometric differences of BNLDs in unilateral PANDO patients between PANDO and non-PANDO sides, as compared with the control group using multidetector computed tomography (CT). Bilateral BNLDs in 39 unilateral PANDO patients and 36 control subjects were retrospectively reviewed. CT images with 0.5-mm thickness were obtained with a 64-slice scanner. The length, volume, coronal orientation type, sagittal orientation angle of BNLD, and relative lacrimal sac-BNLD angle were assessed. The entrance, minimum and distal end transverse diameters (TD) of BNLD was investigated. The mean minimum and distal end BNLD TDs measurements were significantly narrower in PANDO patients, both in PANDO and non-PANDO sides, as compared with the control group (p < 0.001 and p = 0.040, respectively); however, there were no significant differences between PANDO and non-PANDO sides within PANDO patients. The length, entrance TD, volume, coronal orientation type, sagittal orientation angle of BNLD, and relative lacrimal sac-BNLD angle were not significantly different between PANDO patients and control subjects, as well as between PANDO and non-PANDO sides within PANDO patients. The narrow mean minimum and distal end BNLD TD in PANDO patients, in both PANDO and non-PANDO sides, may be associated with PANDO development. The lack of difference between PANDO and non-PANDO sides within PANDO patients and some overlap between PANDO patients and control subjects suggest that narrow BNLD is not the sole factor.

  2. Role of multiphasic multi-detector computed tomography (MDCT in the diagnosis and staging of solid neoplastic renal masses

    Directory of Open Access Journals (Sweden)

    Manal H. Wahba

    2015-03-01

    Conclusion: Multiphase multislice computed tomography combined with CT angiography and CT urography have a major role in solid renal neoplastic masses’ diagnosis, characterization and differentiating benign and malignant tumors.

  3. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    International Nuclear Information System (INIS)

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 ± 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  4. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel [University Duesseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Duesseldorf (Germany); Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael [University Duesseldorf, Medical Faculty, Department of Traumatology and Hand Surgery, Duesseldorf (Germany); Hakimi, Ahmad R. [Universtity Duesseldorf, Medical Faculty, Department of Oral Surgery, Duesseldorf (Germany)

    2012-05-15

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 {+-} 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  5. The Relationship between Organ Dose and Patients Size in Multidetector Computed Tomography (MDCT) Scans Utilizing Tube Current Modulation (TCM)

    OpenAIRE

    Khatonabadi, Maryam

    2013-01-01

    Computed Tomography (CT) has been one of the leading imaging modalities in today's practice of Radiology. Since its introduction in 1970s, its unique tomographic capability has not only prevented countless number of unnecessary surgeries but also saved lives by early detection of disease. Radiation dose from CT has been estimated to contribute to almost 50% of all medical radiation exposures. Concerns about radiation-induced carcinogenesis have resulted in efforts that encourage monitoring an...

  6. Imaging pitfalls, normal anatomy, and anatomical variants that can simulate disease on cardiac imaging as demonstrated on multidetector computed tomography

    International Nuclear Information System (INIS)

    Advances in computed tomography have led to continuous improvement in cardiac imaging. Dedicated postprocessing capabilities, faster scan times, and cardiac gating methods reveal details of normal cardiac anatomy and anatomic variants that can mimic pathologic conditions. This article will review normal cardiac anatomy and variants that can mimic disease. Radiologists should be familiar with normal cardiac anatomy and anatomic variants to avoid misinterpretation of normal findings for pathologic processes

  7. Cuatro años de experiencia en el uso de tomografía computada multidetector en el trasplante de páncreas: aprendiendo junto a los cirujanos Four years of experience in the use of multidetector computer tomography in pancreas transplantation: a lesson learned together with surgeons

    Directory of Open Access Journals (Sweden)

    Hugo José Paladini

    2013-03-01

    .Purpose. To gain knowledge of normal postoperative findings on Multidetector Computed Tomography (MDCT in patients with pancreas transplant and describe the most frequent complications. Topic review. Pancreatic transplantation is currently the only definitive treatment for diabetic patients. In recent years, its use has increased as therapeutic strategy. According to the INCUCAI, in 2001 9 transplants were performed, increasing to 74 in 2011. This increase creates a need for radiologists to gain knowledge of the normal postoperative anatomy and learn to identify the most frequent postoperative complications. The imaging methods used are Doppler / ultrasound, MDCT, conventional angiography and MRI. In patients with good renal function in whom ultrasound is not diagnostic for characterization of complications, the next step is MDCT. At our hospital, 25 pancreatic transplants were performed in 2008-2012. Postoperative complications were suspected clinically or by ultrasound in 19 of them. Fifteen of them were evaluated by CT for further characterization Imaging findings or procedure details. As we learn the surgical techniques that were performed, normal images are described, allowing a correct interpretation of MDCT findings in these patients. The most common post operative complications were: - Vascular: thrombosis, arteriovenous fistula, pseudoaneurysm - Non vascular: pancreatitis, pancreatic fistulas, collections, pneumoperitoneum, ileus. Conclusion: MDCT is a useful method for assessing patients with pancreas transplantation. A clear understanding of the unique anatomy and possible postoperative complications is crucial for the radiologist to guide the monitoring and treatment of this patient.

  8. Value of 64-row spiral CT three-dimensional reconstruction in the repair of tibial plateau fractures%64排螺旋CT三维重建在胫骨平台骨折修复中的价值

    Institute of Scientific and Technical Information of China (English)

    丁燕萍; 杨莹

    2015-01-01

    背景:胫骨平台骨折会抑制膝关节正常功能,严重损伤患者下肢功能,而早期诊断措施对预后效果具有关键作用。以往研究虽已存在多层螺旋 CT 三维重建技术对胫骨平台骨折诊断的相关报道,但将其诊断效果与 X射线检查方式对比较为鲜见。  目的:分析64排螺旋CT三维重建在胫骨平台骨折修复诊治中的应用效果,并与传统X射线诊治结果进行对比。  方法:选择无锡市第九人民医院2012年10月至2013年10月收治的30例胫骨平台骨折患者,对患者进行64排螺旋CT扫描三维重建以及X射线片检查,对检查结果进行分析对比。CT扫描应用GE64排螺旋CT机,扫描范围为胫骨近端,三维重建间距为1 mm,完成扫描后上传工作平台完成图像重建。  结果与结论:通过64排螺旋CT三维重建检查,胫骨平台骨折的程度、有无塌陷、碎骨片存在及移位等均可清晰显示,按照HOHI分型:8例Ⅰ型,7例Ⅱ型,4例Ⅲ型,5例Ⅳ型,3例Ⅴ型,3例Ⅵ型,确诊率为100%;X射线诊断结果显示有25例确诊,有3例为疑似诊断,2例不能确诊,确诊率为83%,两种方式确诊率比较差异有显著性意义(P OBJECTIVE:To analyze the application effect of 64-row spiral CT three-dimensional reconstruction in the repair, diagnosis and treatment of tibial plateau fractures, and compare with diagnostic outcomes of traditional X-ray. METHODS:A total of 30 patients with tibial plateau fractures were selected from Ninth People’s Hospital of Wuxi City from October 2012 to October 2013. Patients were subjected to 64-row spiral CT scanning, three-dimensional reconstruction and X-ray plain film inspection. The inspection results were analyzed and compared. CT scanning used GE64 row spiral CT. Scanning range was the proximal tibia. Spacing of reconstruction was 1 mm. After completing the scan, data were uploaded to a working platform, and

  9. 64排CT气道成像技术在气道异物检查中的临床应用%Clinical application of 64 rows CT airway imaging in the diagnosis of tracheal bronchus foreign body

    Institute of Scientific and Technical Information of China (English)

    赵庆; 齐晨晖; 金艳

    2014-01-01

    目的:评价64排CT气道成像技术对气管支气管异物检查的诊断价值。方法对50例临床怀疑气道异物的患者应用GE Light Speed 64排容积CT(VCT)进行容积扫描,将所得的容积数据经0.625 mm重建后传至工作站,运用CT仿真内窥镜(CTVE)、多平面重组技术(MPR)、容积再现技术+透明化处理(VR+Raysum)、最小密度投影(MinP)对图像进行后处理重建,以支气管镜检查为金标准,评估64排CT检查的敏感性和特异性,并采用χ2检验比较不同后处理方法与支气管镜诊断气管异物形态符合率。结果64排CT扫描结合气道成像技术诊断气道异物的敏感性为100%,特异性为60%,准确率为96%;不同后处理方法(CTVE、MPR、VR+Ray-sum、MinP 4种方法结合)诊断异物形态与支气管镜检查的符合率分别为:98%、87%、82%、42%、100%,不同后处理方法与支气管镜诊断气管异物形态符合率之间差异有统计学意义(χ2=4.810,P<0.05)。结论64排CT气道成像结合不同后处理方法能够提高气道异物诊断的准确性,不同后处理方法联合应用诊断异物形态对指导内窥镜检查或手术有重要意义。%Objective To evaluate the value of 64 rows CT airway imaging in the diagnosis of tracheal bronchus foreign body. Methods Fifty patients with suspected airway foreign body underwent GE Light Speed 64 rows VCT volume scan. The volume data after 0.625 mm reconstruction was send to the workstation, and was recon-structed with CTVE, MPR,VR+ Raysum, MinP. Then taking bronchoscopy as a gold standard, we assessed the sensi-tivity and specificity of 64 rows CT. And we compared the coincidence rate between various post-processing method of airway foreign body and bronchoscopy by Chi square test. Results The sensitivity of 64 rows CT airway imaging in the diagnosis of airway foreign body was 100%, the specificity of it was 60%, and the accuracy of it was 96% . The

  10. Reconstruction of coronary 64-multidetector-row computed tomography angiography in patients with atrial fibrillation. Delete short RR intervals using electorocardiogram

    International Nuclear Information System (INIS)

    The image qualities of coronary 64-multidetector-row computed tomography angiography (CCTA) in patients with atrial fibrillation (Afib) are often not enough. This study clarifies how to use electrocardiogram (ECG)-editing in Afib. We performed CCTA (Aquilion 64 with beam pitch: 0.125, 0.35 s/r) in 33 patients (M/F=24/9, age: 71±9 yr, mean heart rate: 71±12 bpm) with Afib. We injected 5 mg of verapamil into the vein when the mean heart rate (HR) was ≥80 bpm. First, we reconstructed images after deleting short risk ratio (RR) (<800, 750, 700, 650, or 600). Second, we reconstructed images in 4 different methods: (1) end-systolic images with Phase Navi (automatically selecting an optimal phase) (ES-Navi), (2) Mid-diastolic images with Phase Navi (MD-Navi), (3) Mid-diastolic images reconstructed by the ''R + absolute time method'' [Edit-MD (R+)], and (4) Mid-diastolic images reconstructed by the ''R-absolute time method'' [Edit-MD (R-)]. We reconstructed 1 and 2 without ECG-editing, and 3 and 4 were reconstructed after ECG-editing without a data deficit. The quality of the images was classified into 3 ranks: no artifact (3), mild artifact (2), and severe artifact (1). The image quality point of CCTA, reconstructed after deleting RR <750, was similar to RR <800, and RR <750 was even higher than that after deleting HR <600, 650, or 700. The mean image quality point of CCTA that was reconstructed by Edit-MD (R-) or Edit-MD (R+) was significantly higher than ES-Navi or MD-Navi. The high image quality of CCTA could be reconstructed after deleting RR <750 in 76% or after deleting RR <800 in 70% of Afib. The reconstruction using Edit-MD (R-) or Edit-MD (R+) without a data deficit could provide a better quality CCTA than using PhaseNavi in Afib. (author)

  11. Comparison of 16 slice multi-detector computed tomography and breath hold 3D magnetic resonance angiography in the detection of coronary stenosis

    Institute of Scientific and Technical Information of China (English)

    Xin LIU; Zulong CAI; Youquan CAI; Shaohong ZHAO; Ningyu AN; Yuangui GAO

    2006-01-01

    Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.

  12. Comparison of accuracy of aortic root annulus assessment with cardiac magnetic resonance versus echocardiography and multidetector computed tomography in patients referred for transcatheter aortic valve implantation.

    Science.gov (United States)

    Pontone, Gianluca; Andreini, Daniele; Bartorelli, Antonio L; Bertella, Erika; Mushtaq, Saima; Gripari, Paola; Loguercio, Monica; Cortinovis, Sarah; Baggiano, Andrea; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Tamborini, Gloria; Muratori, Manuela; Guaricci, Andrea; Alamanni, Francesco; Ballerini, Giovanni; Pepi, Mauro

    2013-12-01

    The evaluation of the aortic root in patients referred for transcatheter aortic valve implantation is crucial. The aim of the present study was to compare the accuracy of cardiac magnetic resonance (CMR) evaluation of the aortic annulus (AoA) with transthoracic and transesophageal echocardiography and multidetector computed tomography (MDCT) in patients referred for transcatheter aortic valve implantation. In 50 patients, maximum diameter, minimum diameter and AoA, length of the left coronary, right coronary, and noncoronary aortic leaflets, degree (grades 1 to 4) of aortic leaflet calcification, and distance between AoA and coronary artery ostia were assessed. AoA maximum diameter, minimum diameter, and area by CMR were 26.4 ± 2.8 mm, 20.6 ± 2.3 mm, 449.8 ± 86.2 mm(2), respectively. The length of left coronary, right coronary, and noncoronary leaflets by CMR were 13.9 ± 2.2, 13.3 ± 2.1, and 13.4 ± 1.8 mm, respectively, whereas the score of aortic leaflet calcifications was 2.9 ± 0.8. Finally, the distances between AoA and left main and right coronary artery ostia were 16.1 ± 2.8 and 16.1 ± 4.4 mm, respectively. Regarding AoA area, transthoracic and transesophageal echocardiography showed an underestimation (p <0.01), with a moderate agreement (r: 0.5 and 0.6, respectively, p <0.01) compared with CMR. No differences and excellent correlation were observed between CMR and MDCT for all parameters (r: 0.9, p <0.01), except for aortic leaflet calcifications that were underestimated by CMR. In conclusion, aortic root assessment with CMR including AoA size, aortic leaflet length, and coronary artery ostia height is accurate compared with MDCT. CMR may be a valid imaging alternative in patients unsuitable for MDCT. PMID:24045059

  13. Detection of non-ST-elevation myocardial infarction and unstable angina in the acute setting: meta-analysis of diagnostic performance of multi-detector computed tomographic angiography

    Directory of Open Access Journals (Sweden)

    Sarno Giovanna

    2007-12-01

    Full Text Available Abstract Background Multi-detector computed tomography angiography (MDCTA has been increasingly used in the evaluation of the coronary arteries. The purpose of this study was to review the literature on the diagnostic performance of MDCTA in the acute setting, for the detection of non-ST-elevation myocardial infarction (NSTEMI and unstable angina pectoris (UAP. Methods A Pubmed and manual search of the literature published between January 2000 and June 2007 was performed. Studies were included that compared MDCTA with clinical outcome and/or CA in patients with acute chest pain, presenting at the emergency department. More specifically, studies that only included patients with initially negative cardiac enzymes suspected of having NSTEMI or UAP were included. Summary estimates of diagnostic odds ratio (DOR, sensitivity and specificity, negative (NLR and positive likelihood ratio (PLR were calculated on a patient basis. Random-effects models and summary receiver operating curve (SROC analysis were used to assess the diagnostic performance of MDCTA with 4 detectors or more. The proportion of non assessable scans (NAP on MDCTA was also evaluated. In addition, the influence of study characteristics of each study on diagnostic performance and NAP was investigated with multivariable logistic regression. Results Nine studies totalling 566 patients, were included in the meta-analysis: one randomised trial and eight prospective cohort studies. Five studies on 64-detector MDCTA and 4 studies on MDCTA with less than 64 detectors were included (32 detectors n = 1, 16 detectors n = 2, 16 and 4 detectors n = 1. Pooled DOR was 131.81 (95%CI, 50.90–341.31. The pooled sensitivity and specificity were 0.95 (95%CI, 0.90–0.98 and 0.90 (95%CI, 0.87–0.93. The pooled NLR and PLR were 0.12 (95%CI, 0.06–0.21 and 8,60 (95%CI, 5.03–14,69. The results of the logistic regressions showed that none of the investigated variables had influence on the diagnostic

  14. Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Katharina [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)]. E-mail: katharina.anders@idr.imed.uni-erlangen.de; Baum, Ulrich [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Michael [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Ropers, Dieter [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Axel [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Pohle, Karsten [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Daniel, Werner G. [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Bautz, Werner [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Achenbach, Stephan [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)

    2006-03-15

    Purpose: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. Materials and methods: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses {>=}50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. Results: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis {>=}50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic 'negative' graft-CTA. According to

  15. Comparing culprit lesions in ST-segment elevation and non-ST-segment elevation acute coronary syndrome with 64-slice multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W.-C. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: w.c.huang@yahoo.com.tw; Liu, C.-P. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: cpliu@isca.vghks.gov.tw; Wu, M.-T. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Department of Radiology, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: wu.mingting@gmail.com; Mar, G.-Y. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: gymar@isca.vghks.gov.tw; Lin, S.-K. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: skyii89@yahoo.com.tw; Hsiao, S.-H. [Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: a841120@ms3.hinet.net; Lin, S.-L. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: sllin@isca.vghks.gov.tw; Chiou, K.-R. [School of Medicine, National Yang-Ming University, Taipei, Taiwan (China); Cardiovascular Medical Center, Kaohsiung Veterans General Hospital, No. 386, Dar-Chung First Road, Kaohsiung, Taiwan (China)], E-mail: krchiou@isca.vghks.gov.tw

    2010-01-15

    Background: Classifying acute coronary syndrome (ACS) as ST elevation ACS (STE-ACS) or non-ST elevation ACS (NSTE-ACS) is critical for clinical prognosis and therapeutic decision-making. Assessing the differences in composition and configuration of culprit lesions between STE-ACS and NSTE-ACS can clarify their pathophysiologic differences. Objective: This study focused on evaluating the ability of 64-slice multidetector computed tomography (MDCT) to investigate these differences in culprit lesions in patients with STE-ACS and NSTE-ACS. Methods: Of 161 ACS cases admitted, 120 who fit study criteria underwent MDCT and conventional coronary angiography. The following MDCT data were analyzed: calcium volume, Agatston calcium scores, plaque area, plaque burden, remodeling index, and plaque density. Results: The MDCT angiography had a good correlation with conventional coronary angiography regarding the stenotic severity of culprit lesions (r = 0.86, p < 0.001). The STE-ACS culprit lesions (n = 54) had significantly higher luminal area stenosis (78.6 {+-} 21.2% vs. 66.7 {+-} 23.9%, p = 0.006), larger plaque burden (0.91 {+-} 0.10 vs. 0.84 {+-} 0.12, p = 0.007) and remodeling index (1.28 {+-} 0.34 vs. 1.16 {+-} 0.22, p = 0.021) than those with NSTE-ACS (n = 66). The percentage of expanding remodeling index (remodeling index >1.05) was significantly higher in the STE-ACS group (81.5% vs. 63.6%, p = 0.031). The patients with STE-ACS had significantly lower MDCT density of culprit lesions than patients with NSTE-ACS (25.8 {+-} 13.9 HU vs. 43.5 {+-} 19.1 HU, p < 0.001). Conclusions: Sixty-four-slice MDCT can accurately evaluate the stenotic severity and composition of culprit lesions in selected patients with either STE-ACS or NSTE-ACS. Culprit lesions in NSTE-ACS patients had significantly lower luminal area stenosis, plaque burden, remodeling index and higher MDCT density, which possibly reflect differences in the composition of vulnerable culprit plaques and thrombi.

  16. Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies

    Institute of Scientific and Technical Information of China (English)

    Maythem; Saeed; Steven; W; Hetts; Robert; Jablonowski; Mark; W; Wilson

    2014-01-01

    Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume(ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular(approximately 10% of tissue volume), interstitium(approximately 15%) and intracellular(approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types Ⅰ/Ⅲ collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis(e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy(hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging(MRI) has the ability to characterize tissue proton relaxation times(T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI(DE-MRI) and multi-detector computed tomography(DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary catheterization and

  17. Relevant incidental findings at abdominal multi-detector contrast-enhanced computed tomography:A collateral screening?

    Institute of Scientific and Technical Information of China (English)

    Luca; Maria; Sconfienza; Giovanni; Mauri; Claudia; Muzzupappa; Alessandro; Poloni; Michele; Bandirali; Anastassia; Esseridou; Stefania; Tritella; Francesco; Secchi; Giovanni; Di; Leo; Francesco; Sardanelli

    2015-01-01

    AIM: To investigate the prevalence of relevant incidental findings(RIFs) detected during routine abdominal contrast-enhanced computed tomography(Ce CT).METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal Ce CT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs(if needing additional workup) was noted.RESULTS: One thousand forty abdominal Ce CT were performed in 949 patients(528 males, mean age 66 ±14 years). No significant difference was found between inpatients and outpatients age and sex distribution(P > 0.472). RIFs were found in 195/1040(18.8%) Ce CT [inpatients = 108/470(23.0%); outpatients = 87/570(15.2%); P = 0.002]. RIFs were found in 30/440(6.8%) Ce CT with a previous exam and in 165/600(27.5%) without a previous exam(P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different(P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs.CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal Ce CT. Risk of overdiagnosis should be taken into account.

  18. Myocardial Bridging of the Right Coronary Artery inside the Right Atrial Myocardium Identified by ECG-gated 64-slice Multidetector Computed Tomography Angiography

    OpenAIRE

    Yung-Liang Wan; Ming-Shien Wen; Fen-Chiung Lin; Chen-Ju Fu; Huan-Wu Chen; Chien-Cheng Chen; Yuan-Chang Liu

    2010-01-01

    A myocardial bridge (MB) is defined as an intramyocardial course of a major epicardialcoronary artery, and it is mainly confined to the left ventricle and the left anterior descendingcoronary artery. There are rare reports of right coronary MB seen during angiographicexamination. Herein, we present a 49 year-old man with right coronary artery MB withoutluminal narrowing in the diastolic and systolic phases of electrocardiography-gated computedtomography images. The value of multi-detector com...

  19. Application of 64-row spiral CT in the evaluation of invasion of trachea,bronchi,and hilar vessels in central type of lung cancer%MSCT在判断中央型肺癌对气管、支气管及肺门血管侵犯中的价值

    Institute of Scientific and Technical Information of China (English)

    黄宝泉; 郑悦; 张庆武; 曾向廷; 林惠如

    2013-01-01

    Objective: To investigate the value of 64 row spiral computed tomography (MSCT) in the diagnosis of tra chea,bronchi and hilar vascular invasion by central type of lung cancer (CLC). Methods:Seventy five cases of CLC under went MSCT examination with post processing techniques including multiplanar reformation (MPR) ,curved planar reforma tion (CPR) ,volume rendering (VR) ,minimum intensity projection (MinIP) ,maximum intensity projection (MIP) and CT virtual endoscopy (CTVE). The relationship of trachea,bronchi,pulmonary hilar vessels with the neoplasm was studied. Results :Invasion of trachea and bronchi by CLC included extraluminal compression type (38 cases,50. 7%) ,which was showed on CT as compression and/or invasion of bronchi led to uneven stenosis;infiltration of bronchial wall(28 cases,37.3%)12. 0%) showed as protruding of neoplasm into the lumen which led to eccentric stenosis of trachea/bronchi. Altogether 117 hilar vessels were invaded by CLC,of which,95 (81. 2%) could be assessed on CT,showing obvious narrowing or oblitera tion; blood vessels encircled by tumor (n = 12,10. 3%) , and tumor thrombosis (n=10,8. 5%). Conclusion: The anatomic features of trachea,bronchi,and hilar vessels and their spacial relationship with CLC could be accurately assessed on 64 row spiral CT with post processing techniques, which provides significant information in judging whether there are trachea, bronchi, and hilar vessel invasion by CLC.%目的:探讨64排螺旋CT及后处理技术在判断中央型肺癌(CLC)对气管、支气管及肺门血管侵犯中的价值.方法:75例经纤支镜或病理确诊的CLC患者行64排螺旋CT扫描,运用多平面重组、曲面重组、容积再现、最大密度投影、CT仿真内窥镜等后处理技术观察肿瘤与气管、支气管及肺门血管的关系.结果:肿瘤对气管、支气管的侵犯表现为管外压迫型38例(50.7%),CT表现为肿瘤压迫并侵犯支气管,管腔内呈不均匀狭窄;管壁浸润型(28

  20. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  1. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  2. Diagnosis and Treatment Value of 64 Row CT in Children With Secretory Otitis Media%64排CT在儿童分泌性中耳炎诊疗中的作用

    Institute of Scientific and Technical Information of China (English)

    付高尚; 徐艳霞; 韩富根

    2015-01-01

    目的:探讨64排CT在儿童分泌性中耳炎诊断、治疗过程中的意义。方法对2012年8月~2014年8月在本院治疗的76例(131耳)分泌性中耳炎患儿的临床资料进行回顾性分析。结果76例(131耳)分泌性中耳炎患儿当中,其中部分患儿3月后复查CT乳突密度影降低,避免了不必要的手术。结论64排颞骨CT检查对儿童分泌性中耳炎病情严重程度准确诊断提供重要的参考价值。%Objective To investigate the 64 slice CT in the diagnosis of children with secretory otitis media,in the course of treatment significance.Methods From August 2012 to August 2014 in our hospital(76 cases(131 ears)of secretory otitis media in children with clinical data were retrospectively analyzed.Results 76 cases(131 ears)with secretory otitis media in children,including review of CT significantly decreased the mastoid density in march part of the children,to avoid unnecessary operation.Conclusion The diagnostic accuracy of 64 row CT scanning of temporal bone of children with secretory otitis media disease severity and provides an important reference value.

  3. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Science.gov (United States)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  4. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Energy Technology Data Exchange (ETDEWEB)

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  5. A multidetector scintillation camera with 254 channels

    DEFF Research Database (Denmark)

    Sveinsdottir, E; Larsen, B; Rommer, P;

    1977-01-01

    A computer-based scintillation camera has been designed for both dynamic and static radionuclide studies. The detecting head has 254 independent sodium iodide crystals, each with a photomultiplier and amplifier. In dynamic measurements simultaneous events can be recorded, and 1 million total counts...... per second can be accommodated with less than 0.5% loss in any one channel. This corresponds to a calculated deadtime of 5 nsec. The multidetector camera is being used for 133Xe dynamic studies of regional cerebral blood flow in man and for 99mTc and 197 Hg static imaging of the brain....

  6. Evaluation of secondary spontaneous pneumothorax with multidetector CT

    International Nuclear Information System (INIS)

    The purpose of this article is to review the underlying causes of secondary pneumothoraces as observed on multidetector computed tomography (MDCT). Using examples from our institutional experience, we shall illustrate important diagnostic features to indicate the underlying lung disease. Understanding the varied range of conditions is important for accurate diagnosis and facilitation of patient management

  7. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Biscaldi, Ennio, E-mail: ennio.biscaldi@gmail.com [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy); Ferrero, Simone, E-mail: simone.ferrero@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Leone Roberti Maggiore, Umberto, E-mail: ulrm@libero.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Remorgida, Valentino, E-mail: vremorgida@yahoo.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Venturini, Pier Luigi, E-mail: venturini@unige.it [Department of Obstetrics and Gynecology, San Martino Hospital and National Institute for Cancer Research, University of Genoa, Largo Rosanna Benzi, 1, 16132 Genoa (Italy); Rollandi, Gian Andrea, E-mail: rollandi@galliera.it [Department of Radiology, Galliera Hospital, via Mura delle Capuccine 14, 16128 Genoa (Italy)

    2014-02-15

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis.

  8. Multidetector computerized tomography enema versus magnetic resonance enema in the diagnosis of rectosigmoid endometriosis

    International Nuclear Information System (INIS)

    Purpose: To compare the accuracy of multidetector computerized tomography enema (MDCT-e) and magnetic resonance enema (MRI-e) in determining the presence of sigmoid and rectal endometriotic nodules. Materials and methods: 260 women (32.6 ± 4.3 years) with symptoms suggestive of rectosigmoid endometriosis underwent MDCT-e and MRI-e prior to laparoscopy. After retrograde colonic distention and injection of intravenous contrast medium, patients were scanned on a 64-row MDCT scanner. MRI-e was performed on a 1.5 T magnet using an 8 channels phased array coil; intestinal distention was achieved by introducing in the rectum 250–300 ml of ultrasonographic gel diluted with saline solution. Radiological findings were compared with surgical and histological results. Results: 176 women had rectosigmoid endometriosis at surgery. There was no significant difference in the accuracy of MDCT-e (98.5%) and MRI-e (96.9%) in the diagnosis of sigmoid and rectal endometriosis (p = 0.248). The sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of MDCT-e and MRI-e were respectively 98.3%, 98.8%, 99.4%, 96.5%, 81.59, 0.02 and 97.2%, 96.4%, 98.3%, 94.1%, 26.89, 0.03. Conclusions: Both MDCT-e and MRI-e are accurate in the diagnosis of rectal and sigmoid endometriosis

  9. 64排螺旋CT血管成像在脑AVM术后评价的应用研究%Postoperative Evaluation of Brain AVM with the 64-row Spiral CT Augiography

    Institute of Scientific and Technical Information of China (English)

    关国信; 名强; 程彦; 张永生; 王岩; 翁志蓬; 刘海平; 黄正旺; 郑晓昀; 李强

    2015-01-01

    目的:探讨64排螺旋CT血管成像(CTA)在脑动静脉畸形(AVM)术后评价的应用价值。方法:39例脑AVM患者,术前均完善CTA检查,术后1周行CTA随访,术后1个月行DSA随访,由放射科医师与神经外科医师对术后CTA进行共同阅片,并与术前CTA及术后DSA进行对比分析。结果:CTA显示39例脑AVM均为单发,均行开颅切除,4例使用了动脉夹辅助;CTA对脑AVM术后残留评价的敏感度和准确度分别为100%、97.4%,DSA对脑AVM术后残留评价的敏感度和准确度均为100%,两者的诊断敏感度和准确度比较,差异无统计学意义(P>0.05)。结论:应用CTA与DSA对脑AVM术后评价,CTA更为安全、方便,可作为首选方法。%Objective: To study the value of 64-row spiral CT Augiography (CTA) in postoperative of brain AVM. Method:39 patients with brain AVM were completed the CTA examination of preoperative, and they all completed the CTA examination of postoperative review after 1 week, complete the DSA examination of postoperative review after 1 month, and to compare the images together by radiologists and neurosurgeons.Result:39 patients with brain AVM were single, and removal of by craniotomy, 4 cases used the artery clamp in surgery; The postoperative residual of brain AVM that the sensitivity and accuracy of CTA was 100% and 97.4% respectively, and the sensitivity and accuracy of DSA was both 100%. There was no significant difference in the diagnostic sensitivity and accuracy (P>0.05). Conclusion: For application of cerebral AVM postoperative evaluation results of CTA and DSA, the CTA is more safe, convenient, can be used as the preferred method.

  10. Assessment of Cerebral Hemodynamics by 64-Row VCT Perfusion Imaging in Patients with Moya-Moya Disease%64排VCT脑灌注成像对烟雾病的血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    谢安明; 丁耀军

    2014-01-01

    Objective To investigate the changes in cerebral hemodynamics (cerebral blood flow volume,blood capacity,mean transit time and time to peak)using 64-row VCT perfusion im-aging,and to provide imaging evidence for clinical intervention.Methods Thirty patients with moya-moya disease aged 13-49 years (average age 33.8 years,14 males,16 females)were recruited in this study.Cerebral perfusion imaging was performed using a GE LightSpeed VCT scanner at a rate of 5 mL/second and a dose of 50 mL.The scan delay time was 5 seconds and scan time was 45 seconds.Post-processing was conducted with Perfusion 4 software to analyze cerebral blood flow volume,blood capacity,mean transit time and time to peak.Results Of the 30 patients,9 had is-chemic type moya-moya disease and 21 had hemorrhagic type moya-moya disease.The 64-row VCT perfusion imaging showed increased regional cerebral blood flow in 3 patients,decreased re-gional cerebral blood flow in 5,increased regional cerebral blood volume in 3,normal cerebral blood volume in 27,shortened mean transit time and time to peak in 3,and prolonged mean transit time and time to peak in 8.Conclusion Most patients with ischemic type moya-moya disease are characterized by regional hypoperfusion,while patients with hemorrhagic type moya-moya disease are characterized by normal or regional hyperperfusion.The mean transit time and time to peakare sensitive indicators of changes in cerebral hemodynamics.%目的:通过对烟雾病患者进行64排VCT脑灌注成像,了解其脑血流动力学变化情况,包括脑血流量、脑血容量、平均通过时间及达峰时间,为临床干预治疗提供影像学依据。方法30例烟雾病患者,男性14例,女性16例,年龄最大为49岁,最小为13岁,平均年龄为33.8岁。利用 GE公司生产的 LightSpeed VCT螺旋扫描机对烟雾病患者进行灌注扫描,速率5 mL·s-1、剂量50 mL、扫描延迟5 s、扫描时间45 s,然后用该公司配备的 Perfu-sion4

  11. A new acquisition method with pacemaker resetting of coronary multidetector-row computed tomography for reduction of radiation dose in patients with pacemaker

    International Nuclear Information System (INIS)

    We proposed a new acquisition method of coronary multidetector-row CT (MDCT) achieved by pacing rate resetting and/or propranolol or verapamil injection in patients with a pacemaker. Coronary MDCT was undertaken in 57 patients with a pacemaker (DDD: 51, VVI: 6) and in 2975 patients with sinus rhythm as control using Aquilion 64 (Toshiba). Pacing rate was reset to 60 beats per minute (bpm) in DDD, and spontaneous beats were suppressed by propranolol injection. Pacing rate was reset to 70 bpm in atrial fibrillation with VVI, and spontaneous beats were suppressed by verapamil injection. Coronary MDCT was undertaken using as high a beam pitch (BP) as possible. When spontaneous beats were not suppressed, we selected the optimal gantry speed and BP to get the highest temporal resolution. Image quality makes no significant difference between pacemaker and sinus rhythm. When spontaneous beats were completely suppressed (all pacing), mean radiation dose and acquisition time, respectively, decreased by 33.0% and 35.2% in DDD compared with the method recommended by Heart Navi (by Toshiba), and they decreased by 38.1% and 25.9%, respectively, in VVI compared with the method recommended by Heart Navi. We could not estimate coronary stenosis in the proximal right coronary artery by lead artifacts in 30% of DDD pacemakers. In conclusion, the new method is useful for not only reducing radiation dose and acquisition time, but also for maintaining image quality in patients with a pacemaker. (author)

  12. Multidetector CT of blunt abdominal trauma.

    Science.gov (United States)

    Soto, Jorge A; Anderson, Stephan W

    2012-12-01

    The morbidity, mortality, and economic costs resulting from trauma in general, and blunt abdominal trauma in particular, are substantial. The "panscan" (computed tomographic [CT] examination of the head, neck, chest, abdomen, and pelvis) has become an essential element in the early evaluation and decision-making algorithm for hemodynamically stable patients who sustained abdominal trauma. CT has virtually replaced diagnostic peritoneal lavage for the detection of important injuries. Over the past decade, substantial hardware and software developments in CT technology, especially the introduction and refinement of multidetector scanners, have expanded the versatility of CT for examination of the polytrauma patient in multiple facets: higher spatial resolution, faster image acquisition and reconstruction, and improved patient safety (optimization of radiation delivery methods). In this article, the authors review the elements of multidetector CT technique that are currently relevant for evaluating blunt abdominal trauma and describe the most important CT signs of trauma in the various organs. Because conservative nonsurgical therapy is preferred for all but the most severe injuries affecting the solid viscera, the authors emphasize the CT findings that are indications for direct therapeutic intervention. PMID:23175542

  13. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  14. Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT

    International Nuclear Information System (INIS)

    To investigate the feasibility of using a single-dose injection protocol in CT angiography (CTA) of the carotid and coronary artery with 320-row multidetector CT. A total of 82 consecutive patients with suspected carotid artery disease underwent an original CTA protocol aiming at capturing the extra-cranial carotid arteries and coronary arteries simultaneously using 320-row MDCT. The image quality, attenuation, and CNRs of the carotid and coronary arteries were assessed. The lag time (between two separated volumetric acquisitions) was compared between patients with and without cardiac venous opacification (CVO). The contrast medium volume and radiation dose were recorded. The image quality was 99.4 % diagnostic in carotid and 86.9 % in coronary artery segments. The mean attenuation of carotid and coronary arteries ranged from 462.2 Hu to 533.7 Hu, 415.9 Hu to 454.7 Hu respectively. The mean CNR of the carotid and coronary artery ranged from 15.8 to 18.9 and 17.7 to 20.4 respectively. The lag time in patients with and without CVO was 5.75 ± 1.64 s vs. 4.21 ± 1.14 s (p < 0.05). The mean radiation dose was 6.6 ± 4.1 mSv.The mean contrast media volume was 71.9 ± 9.1 ml. The carotid and coronary artery can be imaged simultaneously via our original single-dose injection CTA protocol using 320-row CT with adequate image quality. (orig.)

  15. Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, WeiGuo [The First Affiliated Hospital of Soochow University, Department of Radiology, SuZhou (China); Fudan University, Department of Radiology, Zhongshan Hospital, Shanghai (China); Jin, Hang; Chen, Gang; Chen, Wenfang; Gu, Junying; Zeng, Mengsu [Fudan University, Department of Radiology, Zhongshan Hospital, Shanghai (China)

    2014-07-15

    To investigate the feasibility of using a single-dose injection protocol in CT angiography (CTA) of the carotid and coronary artery with 320-row multidetector CT. A total of 82 consecutive patients with suspected carotid artery disease underwent an original CTA protocol aiming at capturing the extra-cranial carotid arteries and coronary arteries simultaneously using 320-row MDCT. The image quality, attenuation, and CNRs of the carotid and coronary arteries were assessed. The lag time (between two separated volumetric acquisitions) was compared between patients with and without cardiac venous opacification (CVO). The contrast medium volume and radiation dose were recorded. The image quality was 99.4 % diagnostic in carotid and 86.9 % in coronary artery segments. The mean attenuation of carotid and coronary arteries ranged from 462.2 Hu to 533.7 Hu, 415.9 Hu to 454.7 Hu respectively. The mean CNR of the carotid and coronary artery ranged from 15.8 to 18.9 and 17.7 to 20.4 respectively. The lag time in patients with and without CVO was 5.75 ± 1.64 s vs. 4.21 ± 1.14 s (p < 0.05). The mean radiation dose was 6.6 ± 4.1 mSv.The mean contrast media volume was 71.9 ± 9.1 ml. The carotid and coronary artery can be imaged simultaneously via our original single-dose injection CTA protocol using 320-row CT with adequate image quality. (orig.)

  16. Multidetector-row computed tomography (MDCT) for the diagnosis of hepatocellular carcinoma in cirrhotic candidates for liver transplantation: prevalence of radiological vascular patterns and histological correlation with liver explants

    International Nuclear Information System (INIS)

    To define the prevalence of different multidetector-row computed tomography (MDCT) vascular patterns and their histopathological correlation with liver explants, and to evaluate the accuracy of MDCT for the diagnosis of hepatocellular carcinoma (HCC). We retrospectively reviewed 125 cirrhotic patients imaged by MDCT before liver transplantation. Three main vascular patterns were identified: hypervascular lesion with washout (Hyper-L-Wo), hypervascular lesion without washout (Hyper-L) and non-hypervascular lesion (Hypo-L). Radiological findings were matched with histopathology of explants. Positive predictive value (PPV) and likelihood ratio (LR) were 95% and 18.66, respectively, for Hyper-L-Wo; 45% and 0.82 for Hyper-L; and 75% and 3 for Hypo-L of 20 mm or larger. Overall accuracy of MDCT for detection and characterisation of HCC was 89% and 43%, respectively. Sensitivity of MDCT for detection and characterisation was related to the lesion size, ranging from 78% (lesion smaller than 10 mm) to 98% (larger than 20 mm) and from 9% to 64%, respectively. MDCT established the accurate stage of disease in 46% of the patients, underestimated in 52% and overestimated in 2%. In cirrhotic patients, any Hyper-L-Wo detected by MDCT can be confidently considered to be HCC. Hyper-L larger than 10 mm and Hypo-L of 20 mm or larger are at high risk of HCC. However, even using MDCT and the newest imaging protocols, imaging underestimated the diagnosis of small HCC. (orig.)

  17. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Directory of Open Access Journals (Sweden)

    Augusto Cesar Vieira Teixeira

    2013-12-01

    Full Text Available Objective The present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT, with emphasis on complementary findings yielded by volume rendering techniques (VRT and curved multiplanar reconstructions (MPR. Materials and Methods The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and /or obstruction secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results Preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion Although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section.

  18. Research Status Quo of Perfusion Imaging with Multidetector Row Computed Tomography on Esophageal Cancer%食管癌多层螺旋CT灌注成像研究现状

    Institute of Scientific and Technical Information of China (English)

    陈天武; 董志辉

    2011-01-01

    食管癌是常见的恶性肿瘤之一.多层螺旋CT 灌注成像作为一种无创手段,可以在活体状态下评价其微循环.近年来,CT 灌注成像在食管癌的微循环评价、放化疗的疗效判断方面取得进展.本文着重综述多层螺旋CT灌注成像技术在食管癌中的应用研究现状.%Esophageal cancer is one of frequent malignant tumors worldwide. As a noninvasive technique. computed tomography (CT) perfusion imaging could be valuable to assess the microcirculation of esophageal cancer in uivo.Recently, multidetector row CT ( MDCT) perfusion imaging has sparked new interest in the assessment of the microcirculation of esophageal cancer, and therapeutic effects of chemoradiotherapy on this tumor. In this paper, we reviewed the status quo of perfusion imaging with MDCT on esophageal cancer.

  19. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  20. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    International Nuclear Information System (INIS)

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  1. Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Storto, Maria Luigia; Maddestra, Nicola; Bonomo, Lorenzo [Department of Clinical Sciences and Bioimaging, Section of Radiology, University ' ' G. d' Annunzio' ' , Ospedale ' ' SS. Annunziata' ' , Via dei Vestini, 66100, Chieti (Italy)

    2004-08-01

    The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4 x 2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate {<=}70 bpm in all patients. The ECG-synchronized axial images, reconstructed in the mid-diastole, MPR, MIP and 3D-VR images were independently and blindly assessed by two radiologists for graft patency and presence of high grade stenosis. Conventional angiography was the standard of reference. MDCT correctly classified 92/94 patent grafts and 26/28 occluded grafts (sensitivity/specificity 93%/97.8%); sensitivity and specificity of MDCT for assessment of arterial grafts were 100 and 98.7% (77/78 patent grafts and 17/17 occluded grafts). Image quality was considered adequate for assessment of significant stenoses in 62/92 (67%) patent grafts, with a significant differences between LIMA and non-LIMA conduits (44/57 vs. 18/65; P=0.002), according to the coronary vessel area supplied (anterior>lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good (K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation

  2. Advances in multidetector CT diagnosis of pediatric pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Thacker, Paul G. [Dept. of Radiology and Radiological Science, Medical University of South Carolina, Charleston (United States); Lee, Edward Y. [Divi. of Thoracic Imaging, Dept. of Radiology and Medicine, Pulmonary Division Boston Children' s Hospital, Harvard Medical School, Boston (United States)

    2016-04-15

    Although pediatric pulmonary thromboembolism is historically believed to be rare with relatively little information available in the medical literature regarding its imaging evaluation, it is more common than previously thought. Thus, it is imperative for radiologists to be aware of the most recent advances in its imaging information, particularly multidetector computed tomography (MDCT), the imaging modality of choice in the pediatric population. The overarching goal of this article is to review the most recent updates on MDCT diagnosis of pediatric pulmonary thromboembolism.

  3. 64 row CT cerebral perfusion applied research of brain ischemia%64排CT脑灌注对脑组织缺血程度的应用研究

    Institute of Scientific and Technical Information of China (English)

    刘贯清; 肖新兰; 李晓; 黄小宁; 李五根

    2015-01-01

    Objective Application of 64 row CT cerebral perfusion brain tissue ischemia. Methods 40 cases of clinical diag-nosis of acute cerebral infarction,patients with unilateral lobe brain perfusion CT perfusion showed abnormal,in combination with MRI to determine infarct,according to the cerebral blood flow group,group A (low perfusion group) and group B (infarction group), respectively,evaluation of two groups of cerebral blood flow perfusion parameters and comparison analysis. Results Of 40 cases, 18 cases of group A,CTP anomaly low perfusion of figure is determined by MTT extend approximately 1.28 (R),decreased CBF mild,CBV basic no change Or moderately reduced,only determined by MTT extension was statistically significant (P<0.01);Infarc-tion group,22 cases of group B,infarction area surrounding IP abnormal perfusion is determined by MTT extend approximately 1. 48(R),CBF significantly decreased approximately 0.45(R),CBV moderately reduced,which extended determined by MTT was sta-tistically significant (P<0.001),decrease CBF was statistically significant (P<0.01);Infarction district performance is determined by MTT extend approximately 1.64(R),CBF significantly decreased approximately 0.36(R),significantly lower CBV (approximately 0. 37)R. Which determined by MTT extension was statistically significant (P<0.001),CBF decline was statistically significant(P<0.01). Conclusion Brain tissue hypoperfusion area with the infarction in central and peripheral IP area the perfusion parameters have significant differences,according to the variation of perfusion parameters characteristics can make the image on the degree of is-chemic infarction assessment,when rCBF<0.5,suggesting infarction risk is extremely high,the clinical guidance for early interven-tion treatment.%目的:探讨应用64排CT脑灌注评价脑组织缺血程度。方法40例临床诊断急性脑梗塞,CT灌注显示单侧脑叶灌注异常患者,结合MRI判断梗塞,根据脑血流量进行分组,A

  4. Cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion

    International Nuclear Information System (INIS)

    The goal of this study was to investigate imaging results from a coronary CT angiography (CCTA) in chronic coronary total occlusion (CTO) before percutaneous coronary intervention (PCI). In 74 patients with CTO, 34 patients was evaluated by using a 64-row multidetector CT scanner prior to the PCI and 40 control subjects with CTO, who only took PCI, were included. The multiplanar reformation of the heart chambers and three-dimensional CT images were used for determining an optimal view. We analyzed and evaluated the success rates of PCI, length of occluded vessel, calcified plaques, occluded side-branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 Hounsfield unit (HU). Success rates of PCI in the two groups, the control group and the experimental group, were not statistically different (p > 0.05). The mean length of occluded arteries was measured as 25 +/- 11 mm and 26 cases (74%) had an occlusion length > 2 cm. Calcified plaques proximal to occlusion were detected in 19 cases (54%). Occluded side branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 HU were in 11 cases (32%), 9 cases (27%), 6 cases (18%), and 5 cases (15%), respectively. Although there was no correlation between the CCTA findings before PCI and the success rate of PCI, common findings of CCTA in CTO included an occlusion length > 2 cm and calcified plaques proximal to occluded arteries.

  5. Cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion cardiac multidetector row CT before percutaneous coronary intervention as a treatment guide for chronic total occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun; Choi, Dong Hyun [Dept. of Radiology, Chosun University Hospital, Gwangju (Korea, Republic of); Lee, Nae Hee [Dept. of Internal Medicine, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2015-03-15

    The goal of this study was to investigate imaging results from a coronary CT angiography (CCTA) in chronic coronary total occlusion (CTO) before percutaneous coronary intervention (PCI). In 74 patients with CTO, 34 patients was evaluated by using a 64-row multidetector CT scanner prior to the PCI and 40 control subjects with CTO, who only took PCI, were included. The multiplanar reformation of the heart chambers and three-dimensional CT images were used for determining an optimal view. We analyzed and evaluated the success rates of PCI, length of occluded vessel, calcified plaques, occluded side-branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 Hounsfield unit (HU). Success rates of PCI in the two groups, the control group and the experimental group, were not statistically different (p > 0.05). The mean length of occluded arteries was measured as 25 +/- 11 mm and 26 cases (74%) had an occlusion length > 2 cm. Calcified plaques proximal to occlusion were detected in 19 cases (54%). Occluded side branches, tapered occlusion, > 45 degrees angulation of occluded artery, and myocardial density < 50 HU were in 11 cases (32%), 9 cases (27%), 6 cases (18%), and 5 cases (15%), respectively. Although there was no correlation between the CCTA findings before PCI and the success rate of PCI, common findings of CCTA in CTO included an occlusion length > 2 cm and calcified plaques proximal to occluded arteries.

  6. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    Science.gov (United States)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p < 0.05). For the preoperative detection of focal liver lesions, Gd-EOB-DTPA-enhanced MRI had a higher diagnostic value and higher detection rate than iodine-enhanced MDCT. The arterial and the delayed dynamic enhancement patterns, and the gadoxetic-acid-enhanced MR imaging can provide information on the possible degree of cellular differentiation of a HCC, adenoma or metastatic tumor.

  7. Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography: a guide to reliable visual coronary plaque assessments.

    Science.gov (United States)

    de Knegt, Martina C; Linde, Jesper J; Fuchs, Andreas; Nordestgaard, Børge G; Køber, Lars V; Hove, Jens D; Kofoed, Klaus F

    2016-10-01

    To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics. 150 patients, 50 asymptomatic subjects from the general population (low CAD prevalence), 50 symptomatic non-acute coronary syndrome (non-ACS) patients (intermediate CAD prevalence), and 50 ACS patients (high CAD prevalence), matched according to age and gender, were retrospectively enrolled. All coronary segments were evaluated for overall image quality, evaluability, presence of CAD, coronary stenosis, plaque composition, plaque focality, and spotty calcification by four readers. Interobserver agreement was assessed using Fleiss' Kappa (κ) and intra-class correlation (ICC). Widely used clinical parameters (overall scan quality, presence of CAD, and determination of coronary stenosis) showed good agreement among the four readers, (ICC = 0.66, κ = 0.73, ICC = 0.74, respectively). When accounting for heart rate, body mass index, plaque location, and coronary stenosis above/below 50 %, interobserver agreement for plaque composition, presence of CAD, and coronary stenosis improved to either good or excellent, (κ = 0.61, κ = 0.81, ICC = 0.78, respectively). Spotty calcification was the least reproducible parameter investigated (κ = 0.33). Across subpopulations, reproducibility of coronary plaque characteristics generally decreased with increasing CAD prevalence except for plaque composition, (limits of agreement: ±2.03, ±1.96, ±1.79 for low, intermediate and high CAD prevalence, respectively). 320-slice MDCT can be used to assess coronary plaque characteristics, except for spotty calcification. Reproducibility estimates are influenced by heart rate, body size, plaque location, and degree of luminal stenosis.

  8. Multidetector CT and MRI in pancreatic diseases

    International Nuclear Information System (INIS)

    Multidetector CT and MRI are the most efficient non invasive techniques in the assessment of pancreatic diseases. As with MRI, multidetector CT has now become an all in one examination using 2 D and 3 D multiplanar reformations with the ability to perform with high accuracy: a) vascular assessment using MIP reconstruction and b) biliary and pancreatic ducts assessment using minIP reconstruction. This review compares and illustrates the respective advantages of MRI and multidetector CT in the assessment of pancreatic diseases. (authors)

  9. Photon intensity interferometry with multidetectors

    International Nuclear Information System (INIS)

    The technique of two-photon interferometry in heavy ion collisions at the intermediate energies is discussed and the importance of a new methodology, used in the treatment of the experimental data, is evidenced. For the first time, both the relative momentum, qrel, and the relative energy, q0, of the two correlated photons have been simultaneously used to extract the source size and lifetime of the emitting source. As an application, the performances of the BaF2 ball of the MEDEA multidetector as a photon intensity interferometer have been evaluated. The response of such a detector to correlated pairs of photons has been studied through full GEANT3 simulations. The effects of the experimental filter on the photon correlation function have been investigated, and the noise, induced in the correlation signal by cosmic radiation, neutral pion decay, and γ-conversion, has also been estimated. ((orig.))

  10. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  11. Temporal bone trauma and the role of multidetector CT in the emergency department.

    Science.gov (United States)

    Zayas, Julio O; Feliciano, Yara Z; Hadley, Celene R; Gomez, Angel A; Vidal, Jorge A

    2011-10-01

    The temporal bone anatomy is complex, with many critical structures in close association with one another. The temporal bone region comprises cranial nerves V, VI, VII, and VIII; vascular structures such as the internal carotid and middle meningeal arteries; sigmoid sinus; jugular bulb; and sensorineural and membranous structures of the inner ear. Most temporal bone fractures are a result of high-energy blunt head trauma. Multidetector computed tomography (CT) plays a fundamental role in the initial evaluation of patients with polytrauma in the emergency department. Multidetector CT may help identify important structural injuries that may have devastating complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, cerebrospinal fluid leaks, facial nerve paralysis, and vascular injury. Although classifying temporal bone fractures helps physicians understand and predict trauma-associated complications and guide treatment, identifying injury to critical structures is more important for guiding management and determining prognosis than is simply classifying temporal bone fractures into a general category. Many temporal bone fractures and complications may be readily identified and characterized at routine cervical, maxillofacial, and head multidetector CT performed in patients with polytrauma, without the need for dedicated temporal bone multidetector CT. Dedicated temporal bone multidetector CT should be considered when there is a high degree of suspicion for temporal bone fractures and no fractures are identified at head, cervical, or maxillofacial CT. PMID:21997992

  12. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Michael D. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Pena, Antonio J.; Nichols, John H. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Worrell, Stewart [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Bamberg, Fabian [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Dannemann, Nina [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States)], E-mail: uhoffmann@partners.org

    2008-04-15

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 {+-} 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 {+-} 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

  13. The Role Of Multidetector Computed Tomography In The Early Diagnosis Of Invasive Pulmonary Aspergıllosis In Patients With Febrile Neutropenia Undergoing Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Nazan Çiledağ

    2012-03-01

    Full Text Available OBJECTIVE: To evaluate the vessel involvement and the role of multidedector computed tomograpy (MDCT in the early diagnosis of invasive pulmonary aspergillosis (IPA at MDCT in autologous bone morrow transplantation patients with febrile neutropenia and antibiotic-resistant fever of unknown origin with clinically suspected IPA. METHODS: 74 pulmonary MDCT examinations of 37 consecutive hematopoietic stem cell transplantation patients with febrile neutropenia with clinically suspected IPA were retrospectively evaluated. RESULTS: The diagnosis of IPA was made according to according to the Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Consensus Group criteria and 0, 14, 11 patients were diagnosed as proven, probable, possible IPA, respectively. Among 25 cases accepted as probable and possible IPA, all patients had pulmonary MDCT findings consistent with IPA. Remaining 12 patients were accepted as having fever of unknown origin (FUO and in these 12, MDCT showed patent vessel. In patients with probable/possible IPA, 72 focal pulmonary lesions were detected. In 41 of 72 (57%, vascular occlusion was detected. The CT halo sign was present in 25 of 41 (61% lesions. A clinical improvement, resolution of fever was observed following antifungal therapy in 19 (76% of 25 patients with probable/possible IPA. Six (25% patients diagnosed as IPA died during follow-up. Transplant related mortality at day 100 in patients with IPA and FUO were found to be 24% and 0%, respectively. CONCLUSION: In conclusion, MDCT has a potential role in early diagnosis of IPA by detection of vessel occlusion.

  14. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  15. Multidetector development: tests with a phthalocyanine crystal

    International Nuclear Information System (INIS)

    As part of a program to develop methods of using multidetectors for neutron crystallography, a total of 1277 diffracted intensities from a crystal of metal-free phthalocyanine were collected using a prototype 2-dimensional detector. Two different algorithms for peak integration are under consideration. These are described briefly and the results are compared in detail

  16. MARS - a multidetector array for reaction studies

    International Nuclear Information System (INIS)

    The proposal for MARS, a Multidetector Array for Reaction Studies is presented. MARS consists of a large, high-vacuum vessel enclosing an array of 128 scintillation detectors for use in studies of heavy-ion collisions at TASCC. The instrument will be funded and owned jointly by AECL and NSERC

  17. CHIMERA Multidetector at Laboratori Nazionali del Sud

    International Nuclear Information System (INIS)

    The installation of CHIMERA multidetector, designed in order to study central collisions in heavy ion reactions at intermediate energy, is going on at LNS and the first experiment with the forward part (688 telescopes) is running since May 1999. The aim of this contribution is to present the status of the project

  18. Instrumentation for multi-detector arrays

    Indian Academy of Sciences (India)

    R K Bhowmik

    2001-07-01

    The new generation of detector arrays require complex instrumentation and data acquisition system to ensure increased reliability of operation, high degree of integration, software control and faster data handling capability. The main features of some of the existing multi-detector arrays like MSU 4 array, Gammasphere and Eurogam are summarized. The instrumentation for the proposed INGA array in India is discussed.

  19. Esophageal injuries: Spectrum of multidetector row CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lutio di Castelguidone, Elisabetta de [Department of Radiology, I.N.T., IRCCS Fondazione G. Pascale, Via M. Semmola, I-80131 Naples (Italy)]. E-mail: e.delutio@virgilio.it; Merola, Stefanella [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Pinto, Antonio [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Raissaki, Maria [Department of Radiology, University Hospital of Iraklion, University of Crete Medical School, P.O. Box 1352, 711 10 Iraklion Crete (Greece); Gagliardi, Nicola [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Romano, Luigia [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy)

    2006-09-15

    Background: Aim of this study is to illustrate the multidetector row computed tomographic findings related to oesophageal injuries and their significance for therapeutic decisions. Method: From April 2002 to April 2005 we studied 16 patients with suspected oesophageal injury. Ten patients underwent standard chest radiograph, while five patients with suspected foreign body ingestion were submitted to cervical plain film and gastrografin swallow study. All 16 patients underwent multidetector row CT examination. Results: In six patients with cervical, thoracic and abdominal trauma, CT showed the presence of thoracic traumatic lesions and findings suggestive of perforation of the oesophagus. In five patients with foreign body ingestion cervical radiography was positive in only one case, while CT showed the presence of a foreign body in all cases. In three patients with post-intubation complications, CT showed the presence of perioesophageal fluid collection containing small gas bubbles in two cases and an oesophageal-aortic fistula in one case. In the remaining two patients with suspected spontaneous oesophageal perforation, CT demonstrated an oesophageal wall oedema and thickening in one case, and oesophageal fluid distension with perioesophageal small bubbles gas and fluid in the second case. Conclusion: Oesophageal injuries, when complicated with perforation, constitute a life-threatening condition. Knowledge of the CT signs of oesophageal injuries has important implications for the role of imaging at the time of initial diagnosis.

  20. Association between coronary artery calcification score as assessed by multi-detector row computed tomography and cardiovascular risk factors%冠状动脉钙化积分与冠心病危险因素的相关性

    Institute of Scientific and Technical Information of China (English)

    张剑; 韩雅玲; 荆全民; 王效增; 李毅; 张磊; 霍勇; 张岩

    2011-01-01

    Objective The coronary artery calcification (CAC) score determined by multi-detector row computed tomography ( MDCT) predicts the onset of coronary artery disease (CAD). In addition, cardiovascular risk factors also predict the mortality of CAD. Therefore, the aim of this study was to assess whether or not the CAC score is associated with cardiovascular risk factors. Methods A total of 9847 consecutive patients with suspected coronary artery disease underwent coronary angiography between January 2001 and March 2007 at 20 centers of China were enrolled. The subjects consisted of 311 consecutive patients with suspected CAD who underwent MDCT. The body mass index, blood pressure, blood glucose, and serum total cholesterol, triglyceride and low-density lipoprotein cholesterol ( LDL-C) and high-density lipoprotein cholesterol ( HDL-C) were measured. Results When the patients were divided into three groups according to the CAC score [low (0-12 IU), intermediate ( 13 - 445 ) and high ( 5* 446) ], the classification score was significantly associated with age, prevalence of cardiovascular history and diabetes mellitus and HDL-C. In multivariate logistic regression analysis, age ( P = 0. 013) and plasma levels of high-density lipoprotein cholesterol ( P = 0.020 ) remained significant independent variables for the classification. Conclusions Age, prevalence of cardiovascular history and diabetes mellitus and HDL-C were significantly associated with the classification according to the CAC score. The detection of CACS by MSCT could provide reliable and efective evidence for diagnosis of CHD in patients with cardiovascular risk factors.%目的 经多层冠状动脉CT检查测定的冠状动脉钙化积分对冠心病的诊断具有一定预测价值.而冠心病的危险因素与冠心病的发生、发展、结局和预后密切相关.我们旨在探讨冠状动脉钙化积分与冠心病诸多危险因素之间是否具有相关性.方法 入选2001年1月至2007年3

  1. Double Chooz Improved Multi-Detector Measurements

    CERN Document Server

    CERN. Geneva

    2016-01-01

    The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero θ13 with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of θ13 followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC’s unique almost "iso-flux" site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of θ13 with respect to the world average. We will address this issue in this seminar. The combined "reactor-θ13" measurement is expected to ...

  2. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  3. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Wanner, Matthew R.; Karmazyn, Boaz [Indiana University School of Medicine, Riley Hospital for Children, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Fan, Rong [Indiana University School of Medicine, Riley Hospital for Children, Department of Pathology and Laboratory Medicine, Indianapolis, IN (United States)

    2015-12-15

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  4. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    International Nuclear Information System (INIS)

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  5. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    P. Symersky; R.P.J. Budde; P. Westers; B.A.J.M. de Mol; M. Prokop

    2011-01-01

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall ti

  6. Multidetector CT imaging of mechanical prosthetic heart valves : quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods

  7. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, P.; Budde, R.P.; Westers, P.; Mol, B.A. de; Prokop, M.

    2011-01-01

    OBJECTIVES: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. METHODS

  8. A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Roberto Moraes Bastos

    2011-01-01

    Full Text Available OBJECTIVE: The purpose of this study was to improve the use of 64-channel multidetector computed tomography using lower doses of ionizing radiation during follow-up procedures in a series of patients with endovascular aortic aneurysm repair. METHODS: Thirty patients receiving 5 to 29 months of follow-up after endovascular aortic aneurysm repair were analyzed using a 64-channel multidetector computed tomography device by an exam that included pre-and postcontrast with both arterial and venous phases. Leak presence and type were classified based on the exam phase. RESULTS: Endoleaks were identified in 8/30 of cases; the endoleaks in 3/8 of these cases were not visible in the arterial phases of the exams. CONCLUSION: The authors conclude that multidetector computed tomography with pre-contrast and venous phases should be a part of the ongoing follow-up of patients undergoing endovascular aortic aneurysm repair. The arterial phase can be excluded when the aneurism is stable or regresses. These findings permit a lower radiation dose without jeopardizing the correct diagnosis of an endoleak.

  9. Role of multi-detector computed tomography (MDCT in management of post percutaneous nephrolithotomy (PCNL bleeding [v1; ref status: indexed, http://f1000r.es/205

    Directory of Open Access Journals (Sweden)

    Arvind P Ganpule

    2013-11-01

    Full Text Available Objective: To evaluate the role of multidetector computerized tomography (MDCT angiography in post percutaneous nephrolithotomy (PCNL bleed and compare findings with conventional angiography (CA. Material and methods: We conducted a retrospective analysis of patients who had post PCNL bleeding and subsequently underwent a MDCT angiography followed by CA. We reviewed eight patients, who presented between January 2009 and January 2013. We performed a MDCT angiography on a 16 slice GE bright speed CT scanner. All angiographies were done by using the Digital Subtraction Angiography Suite. The angioembolisation, if required, was conducted by an interventional nephrologist, specializing in therapeutic embolisation. Results: The mean age of the patients was 42±17 years. Mean time of post PCNL bleed presentation was 10.06±7.9 days. Five patients presented with aneurysm and three presented with an AV fistula with pseudoaneurysm. The right renal unit was involved in six cases and the left in two cases. The lower polar segmental artery was involved in six cases and the upper polar artery in two cases. The CA and MDCT findings matched in all cases and the MDCT helped the clinician to assess and embolise the appropriate arterial tree. Conclusion: MDCT is rapid, reproducible and noninvasive. MDCT angiography performed in the setting of post PCNL bleeding provides an accurate assessment of the site and nature of bleeding. The MDCT angiography matched the CA findings in all patients in the present study.

  10. 64-Row Detector CT Angiography of Aortoiliac and Lower Extremity Arteries:Effect of Using a Monitoring Scan at Knee Level on Image Quality%64层螺旋CT下肢动脉血管造影:腘动脉监测触发对图像质量的影响

    Institute of Scientific and Technical Information of China (English)

    周淑琴; 彭振鹏; 周旭辉; 严超贵; 高樱; 林少春; 李树荣

    2011-01-01

    Purpose: To evaluate the effect of using a monitoring scan at knee level on image quality for 64 - row detector CT angiography of aortoiliac and lower extremity arteries.Methods: The study was performed with approval of the institutional review board and with informed consent of the subjects.A total of 62 subjects were included in this prospective study.The monitoring trigger was sited at knee level of the popliteal artery for CT angiography.Image analysis was performed as follows: Subjective evaluation of the image quality of aorto - iliac area, femoro - popliteal district and run - off vessels with VR and MIP reconstruction respectively; Calculation of the CT value of aorto - iliac area, femoro -popliteal district and run - off vessels; and evaluation of the data by variance analysis; Evalution of the distal arterial and venous visibility.Results: The monitoring scan at the level of the popliteal artery was unavailable in 1 case.The overall quality of VR images in 33 of the 61 patients (54.1%) were categorized as excellent, in 23(37.7% ) as good, in 4(6.6% ) as fair, and in 1(1.6% ) as poor, the rate of excellent and good was 91.8%; MIP images in 41(67.2%)as excellent, in 17(27.9%)as good, for 2(3.3%)as fair, and for 1(1.6%) as poor, the rate of excellent and good was 95.1%.There was a high consistency between two observers (VR: Kappa = 0.719; MIP: Kappa = 0.678).The mean CT values measured at aorto - iliac area, femoro - popliteal district and run - off vessels were 536.42Hu ± 99.68 Hu(352.43 ~ 742.71Hu),541.72Hu ± 119.05 Hu(338.38 ~ 800.75Hu) and 421.29Hu ± 97.15 Hu(264.58 ~ 739.00Hu), respectively.There were significant differences among these three segments(F = 25.25, P = 0.00).The rate of distal arterial and venous visibility were 98.9% (1531/1549)and 22.9% (14/61), respectively.Conclusion: Using a monitoring scan at knee level was useful for 64- row detector CT angiography of aortoiliac and lower extremity arteries

  11. Multidetector CT of the Pancreas

    Directory of Open Access Journals (Sweden)

    Rossella Graziani

    2008-07-01

    Full Text Available Purpose. This book is a practical overview of pancreatic computer tomography (CT based on the large experience of the contributors. It is dedicated to Carlo Procacci a well known radiologist of Verona who died in 2004. Content. The book is divided into 10 chapters covering the different aspects of diagnostic CT of the pancreas. The various radiological aspects of acute and chronic pancreatitis, exocrine and endocrine pancreatic cancer (adenocarcinoma, neuroendocrine tumors, cystic cancer, rare neoplasms, traumatic abnormalities, imaging aspects of the gland after surgery and finally imaging findings after pancreas transplantation are reported in detail. Comment. We would emphasize that the characteristics of imaging of the common pancreatic diseases are described in addition to unusual or rare aspects of pancreatic pathology. The iconography is very rich and it is of excellent quality and it will help the radiologist to deal with individual cases particularly complex. Another important aspect of the book is that the initial approach of the various pancreatic diseases is based on clinical, surgical and pathological aspects and their relationship with imaging findings. Limitation. It is a great pity that the book for its importance is written in Italian language and for this reason it can not have an international appreciation. Final note. The radiologists will find in the book all the information useful for their daily practice. The internists, gastroenterologists and surgeons also will found useful information to better understand the information given by the modern CT radiology.

  12. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature th...

  13. 64层螺旋CT脑灌注成像联合CT血管造影评价颅内外血管搭桥术后疗效%Assessment of cerebral internal and external vascular bypass graft in patients with single middle cerebral artery stenosis or occlusion by combining 64-row CT cerebral perfusion with angiography

    Institute of Scientific and Technical Information of China (English)

    陈天金; 朱栓庄; 温有信; 王耀彬; 韩向东; 白莹; 于旋

    2012-01-01

    Objective To assess the curative effect of cerebral internal and external vascular bypass graft in patients with sin -gle middle cerebral artery (MCA) stenosis or occlusion by combining 64 -row CT cerebral perfusion (CTP) with angiography ( CTA ). Methods Patients with middle cerebral artery stenosis or occlusion were recruited and underwent superficial temporal artery and mid -die cerebral artery(STA -MCA) bypass graft between March 2009 and Mar 2011. CTP and CTA examinations were performed in all patients before and after operation. The cerebral perfusion parameters were analyzed quantitatively and qualitatively . The origin, travel and anastomotic stoma of bypass grafts were evaluated by reconstructed CTA images . Results 46 patients were found with severe MCA stenosis or occlusion. The time to peak (TTP) and relative mean transit time (rMTT) images before therapy displayed the existence of perfusion delay. The relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCRV) images did not change significantly. The decrease of TTP and rMTT after therapy was of statistical significance ( P 0.05). In reconstructed CTA images , 82 bridge vessels were well displayed, including double bridges in 39 patients. The accuracy of CTA examination was 96.5%. All the bypass grafts were well shown and the anastomotic stomas were unobstructed. Conclusions It is feasible to evaluate the curative effects of cerebral internal and ex — ternal vascular bypass graft by combining CTP images of cerebral perfusion after therapy with CTA images of cerebral internal and exter -nal bypass grafts.%目的 探讨64层螺旋CT脑灌注成像(CT perfusion,CTP)联合CT血管造影(CT angiography,CTA)评价单侧大脑中动脉(middle cerebral artery,MCA)重度狭窄(闭塞)颅内外血管搭桥术后疗效的可行性.方法 46例拟行颅内外血管搭桥术患者,术前、后均行CTP及CTA检查.计算脑灌注参数图,对治疗前后脑灌注参数进行定量和定性对

  14. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiri [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic)], E-mail: ferda@fnplzen.cz; Hora, Milan [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic); Hes, Ondrej [Institut of Pathology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Reischig, Tomas [Department of Internal Medicine, Nephrology Unit, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Kreuzberg, Boris; Mirka, Hynek; Ferdova, Eva; Ohlidalova, Kristyna; Baxa, Jan [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Urge, Tomas [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic)

    2007-08-15

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC

  15. Diagnóstico auxiliado por computador na detecção de nódulos pulmonares pela tomografia computadorizada com múltiplos detectores: estudo preliminar de 24 casos Detection of pulmonary nodules by computer-aided diagnosis in multidetector computed tomography: preliminary study of 24 cases

    OpenAIRE

    Julia Capobianco; Dany Jasinowodolinski; Gilberto Szarf

    2008-01-01

    OBJETIVOS: Avaliar o desempenho de um programa para auxílio na detecção de nódulos pulmonares em tomografia computadorizada com múltiplos detectores (TCMD). MÉTODOS: Foram avaliadas 24 tomografias computadorizadas de tórax consecutivas realizadas no Centro de Medicina Diagnóstica Fleury no período de 07/10/2006 a 19/10/2006 usando um tomógrafo helicoidal multidetectores de 64 canais. O estudo compreendeu 12 pacientes do sexo feminino e 12 do sexo masculino, com idades variando entre 35 e 77 a...

  16. Evaluation of tracheal bronchus in Chinese children using multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Zhu; Lin, Zhang [Shanghai Children' s Medical Center, Department of Radiology, Shanghai (China)

    2007-12-15

    Tracheal bronchus is a congenital bronchial anomaly. The diagnosis should be considered early in intubated patients. Multidetector computed tomography (MDCT) is the newest modality for evaluating tracheal bronchus. To evaluate the utility of 16-slice MDCT in children with tracheal bronchus and to characterize the frequency of tracheal bronchus in children with congenital heart disease. From June 2005 to May 2007, 3,187 consecutive children (1,124 with congenital heart disease and 2,063 without congenital heart disease) underwent MDCT examination. Minimum-intensity projection reconstruction was performed to show the tracheobronchial tree in every case. Tracheal bronchus was found in 42 children (3.74%) with congenital heart disease but in only 6 children (0.29%) without congenital heart disease. Among the 48 children with tracheal bronchus, 45 had right-side tracheal bronchus and 3 had bilateral tracheal bronchi with heterotaxy syndrome. The diagnostic sensitivity of MDCT was 100% (48/48). MDCT is a reliable imaging technique for the diagnosis of tracheal bronchus. Our data showed that right-side tracheal bronchus was more common and bilateral tracheal bronchi usually occurred with heterotaxy syndrome. In addition, tracheal bronchus often occurred with congenital heart disease. The angle between the tracheal bronchus and the trachea is important and should be measured. (orig.)

  17. Accessory cardiac bronchus: Proposed imaging classification on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Min; Kim, Young Tong; Han, Jong Kyu; Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of)

    2016-02-15

    To propose the classification of accessory cardiac bronchus (ACB) based on imaging using multidetector computed tomography (MDCT), and evaluate follow-up changes of ACB. This study included 58 patients diagnosed as ACB since 9 years, using MDCT. We analyzed the types, division locations and division directions of ACB, and also evaluated changes on follow-up. We identified two main types of ACB: blind-end (51.7%) and lobule (48.3%). The blind-end ACB was further classified into three subtypes: blunt (70%), pointy (23.3%) and saccular (6.7%). The lobule ACB was also further classified into three subtypes: complete (46.4%), incomplete (28.6%) and rudimentary (25%). Division location to the upper half bronchus intermedius (79.3%) and medial direction (60.3%) were the most common in all patients. The difference in division direction was statistically significant between the blind-end and lobule types (p = 0.019). Peribronchial soft tissue was found in five cases. One calcification case was identified in the lobule type. During follow-up, ACB had disappeared in two cases of the blind-end type and in one case of the rudimentary subtype. The proposed classification of ACB based on imaging, and the follow-up CT, helped us to understand the various imaging features of ACB.

  18. The Role of Multidetector CT in the Diagnosis of Retroperitoneal Fibrosis: Report of a Case

    International Nuclear Information System (INIS)

    Herein, we report a 40-year old man who presented with flank and abdominal pain with dilatation of the bilateral pyelocalyceal system detected in ultrasonography. Computed Tomography (CT) scan showed a soft tissue mass at the level of the fourth and fifth lumbar vertebrae in the retroperitoneal region. There were no blood flow signals in 64-slice multidetector CT (MDCT) which confirms the Retroperitoneal Fibrosis (RPF). Pathological examination showed infiltration of plasma cells, macrophages, lymphocytes and eosinophils accompanied by fibrosis, which is consistent with idiopathic RPF. In conclusion, 64-slice MDCT imaging is useful in the diagnosis of RPF

  19. On the cosmic-ray induced background in neutral pion production measurements with a BaF2 multidetector

    International Nuclear Information System (INIS)

    The problem of the cosmic-ray induced background in neutral pion production measurements with barium fluoride multidetectors is discussed. As a reference example, the response to cosmic rays of the MEDEA photon spectrometer is studied. The interaction of the cosmic radiation with the experimental filter has been treated by means of full Monte Carlo computer simulations with the GEANT3 code. The results of the simulations are compared with experimental data and general criteria to minimize the cosmic background are discussed. ((orig.))

  20. Estudio vascular renal por TC multidetector de 64 canales 64-Multidetector row CT for the Renal Vascular Study

    Directory of Open Access Journals (Sweden)

    Daniela Stoisa

    2009-03-01

    Full Text Available Objetivo: Mostrar las diversas variantes anatómicas vasculares tanto arteriales como venosas en el estudio angiográfico renal por tomografìa computada multidetector (TCMD de 64 canales, dada su implicancia en un eventual planeamiento quirúrgico. Material y métodos: Evaluamos retrospectivamente 26 estudios realizados con tomógrafo Philips Brilliance de 64 canales. Se obtuvieron secuencias sin contraste y postcontraste e.v. en fases arterial y venosa, administrado con bomba inyectora doble cabezal. Para una fase arterial apropiada se utilizó técnica de bolus track. Las imágenes fueron posteriormente procesadas en Workstation Philips Brilliance 190P en un tiempo promedio de 30 minutos y reconstruidas con técnicas MIP y volumétrica. Resultados: Dentro de las variantes anatómicas arteriales, encontramos: bifurcaciones prehiliares (n=3, arterias accesorias (n=4 y arterias polares (n=9. Dentro de las variantes venosas fueron halladas: venas renales múltiples (n=5, venas circumaórticas (n=2, retroaórticas (n=2 y vena tributaria lumbar prominente (n=1. Conclusión: El estudio vascular renal adquiere importancia en el planeamiento quirúrgico en casos de nefrectomías parciales, laparoscópicas y en el transplante renal. Esto otorga suma utilidad al estudio de TCMD de 64 canales por su eficacia diagnóstica, dada la alta calidad de las reconstrucciones obtenidas, llegando a igualar a la angiografía digital, sin ser un método invasivo.Purpose: To show the wide range of anatomical vascular variants, arterial and venous, that can be seen in the angiographic renal study using 64-multidetector-row computed tomography (64-MDCT, due to its importance in an eventual surgical planning. Material and Methods: We have evaluated retrospectively 26 studies that have been done using a 64 channels Philips Brilliance CT scanner. We have obtained non enhanced and both in arterial and venous enhanced sequences. For the injection of the contrast material we

  1. A pictorial review of acute aortic syndrome: discriminating and overlapping features as revealed by ECG-gated multidetector-row CT angiography

    OpenAIRE

    Ueda, Takuya; Chin, Anne; Petrovitch, Ivan; Fleischmann, Dominik

    2012-01-01

    Background The term "acute aortic syndrome" (AAS) encompasses a spectrum of life-threatening conditions characterized by acute aortic pain. AAS traditionally embraces three abnormalities including classic aortic dissection, intramural haematoma, and penetrating atherosclerotic ulcer. Although the underlying etiologies and conditions predisposing to AAS are diverse, the clinical features are indistinguishable. Methods Multidetector-row computed tomography (CT) with electrocardiographic gating ...

  2. Multidetector CT of Mandibular Fractures, Reductions, and Complications: A Clinically Relevant Primer for the Radiologist.

    Science.gov (United States)

    Dreizin, David; Nam, Arthur J; Tirada, Nikki; Levin, Martin D; Stein, Deborah M; Bodanapally, Uttam K; Mirvis, Stuart E; Munera, Felipe

    2016-01-01

    After the nasal bones, the mandible is the second most common site of facial fractures, and mandibular fractures frequently require open reduction. In the trauma injury setting, multidetector computed tomography (CT) has become the cornerstone imaging modality for determining the most appropriate treatment management, fixation method, and surgical approach. Multidetector CT is also used to assess the adequacy of the reduction and evaluate potential complications in the postoperative period. For successful restoration of the mandible's form and function, as well as management of posttraumatic and postoperative complications, reconstructive surgeons are required to have a detailed understanding of mandibular biomechanics, occlusion, and anatomy. To provide added value in the diagnosis, treatment planning, and follow-up of mandibular fractures, radiologists should be aware of these concepts. Knowledge of the techniques commonly used to achieve occlusal and anatomic reduction and of the rationale behind the range of available treatment options for different injury patterns-from isolated and nondisplaced fractures to multisite and comminuted fractures-also is essential. This article focuses on the use of multidetector CT for pre- and postoperative evaluation of mandibular fractures and outlines fundamental concepts of diagnosis and management-beginning with an explanation of common fracture patterns and their biomechanical underpinnings, and followed by a review of the common postoperative appearances of these fractures after semirigid and rigid fixation procedures. Specific considerations regarding fractures in different regions of the tooth-bearing and non-tooth-bearing mandible and the unique issues pertaining to the edentulous atrophic mandible are reviewed, and key features that distinguish major from minor complications are described. (©)RSNA, 2016. PMID:27618328

  3. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  4. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  5. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  6. Application of multidetector system in analysis of industrial processes

    International Nuclear Information System (INIS)

    Simultaneous application of several scintillation detectors in stimulus response method with radiotracer enable to study flow of material (gas, liquids or solid) in a group of apparatuses or in one apparatus with a complex flow structure. Good acquisition system and proper software for data evaluation and for flow structure modeling is used in the both cases. Several scintillation detectors can be used for valuation of an axial mean velocity profile of solid material in a horizontal rotary kiln. The axial profile of velocity is important technological parameter as the changes of physical and chemical characters of material are cause of the mean velocity changes. The estimation of axial distribution of material in horizontal rotary calcination kiln from production of pigments (TiO2) is presented as an example of utilization of the measured velocity axial profile for obtaining interesting information. Reliable complex flow analysis in one apparatus suppose using collimated scintillation detectors which are situated close to the wall of apparatus. In this case the adequate description of relation between detected values and radiotracer concentration are required. Simple relation was presented for the model of parallel flow and used for flow analysis in Fluidized Catalytic Cracking reactor. Complex flow analysis with multidetector system was also used for verification of numerical results by Computer Fluid Dynamics (CFD) models. The required relation for detection chain was in this case received on the basis of Point Source Response of the detector measured in the system. Special program has been prepared for calculation of detected values of local responses from tracer concentration file received by commercial software for CFD models. The verification of results of CFD model by measurement of RTD and local responses is demonstrated on liquid flow analysis in a pilot plant of heat exchanger

  7. Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: Initial results

    Institute of Scientific and Technical Information of China (English)

    Miriam Klauβ; Max Sch(o)binger; Ivo Wolf; Jens Werner; Hans-Peter Meinzer; Hans-Ulrich Kauczor; Lars Grenacher

    2009-01-01

    AIM: To evaluate the use of three-dimensional imaging of pancreatic carcinoma using multidetector computed tomography (CT) in a prospective study. METHODS: Ten patients with suspected pancreatic tumors were examined prospectively using multidetector CT (Somatom Sensation 16, Siemens, Erlangen, Germany). The images were evaluated for the presence of a pancreatic carcinoma and invasion of the peripancreatic vessels and surrounding organs. Using the isotropic CT data sets, a three-dimensional image was created with automatic vascular analysis and semiautomatic segmentation of the organs and pancreatic tumor by a radiologist. The CT examinations and the three-dimensional images were presented to the surgeon directly before and during the patient's operation using the Medical Imaging Interaction Toolkit-based software "ReLiver". Immediately after surgery, the value of the two images was judged by the surgeon. The operation and the histological results served as the gold standard. RESULTS: Nine patients had a pancreatic carcinoma (all pT3), and one patient had a serous cystadenoma. One tumor infiltrated the superior mesenteric vein. The infiltration was correctly evaluated. All carcinomas were resectable. In comparison to the CT image with axial and coronal reconstructions, the three-dimensional image was judged by the surgeons as better for operation planning and consistently described as useful. CONCLUSION: A 3D-image of the pancreas represents an invaluable aid to the surgeon. However, the 3D-software must be further developed in order to be integrated into daily clinical routine.

  8. 2型糖尿病患者冠状动脉粥样硬化与视网膜病变的关系%Relationship Between Retinopathy and Coronary Atherosclerosis Determined by Coronary 64-Slice Multidetector Computed Tomography Angiography in Type 2 Diabetes

    Institute of Scientific and Technical Information of China (English)

    魏富春; 戎健; 陈玉群; 干雪梅; 于长青; 陈静; 杨沛; 陈金华

    2013-01-01

    Aim To evaluate the relationship between diabetic retinopathy (DR) and subclinical coronary atherosclerosis (CAs) on coronary 64-slice multidetector computed tomography angiography (MDCT) in individuals with type 2 diabetes mellitus.Methods From July 2007 to December 2009,114 and 124 type 2 diabetic patients with and without CAs were enrolled.They received fundus photochromy,coronary 64-slice multidetector computed tomography angiography,physical examination,and measurement of fasting plasma glucose (FPG),glycosylated haemoglobin (HbAlc),plasma lipid profile,estimated glomerular filtration rate (eGFR) and urinary albumin excretion rate (UAER).Then the analysis of the relationship among the detection and measurement outcomes were conducted.Results Diabetic patients with CAs had a higher prevalence of DR than those without CAs (67.5% vs 33.1%,P < 0.001).After adjustment for the traditional risk factors for cardiovascular disease,CAs was independently associated with DR (OR =5.0,95% CI 2.6~ 9.8).There was significant difference in the prevalence of CAs by the number of CAs vessels among patients without DR (NDR),those with pre-proliferative retinopathy (pre-PDR) and those with proliferative retinopathy (PDR) (P <0.01).The prevalences for CAs,the prevalences of CAs ≥3 vessels involved by plaque,and proportions of vessels with significant coronary plaque and of involved vessels in all detected coronary arteries were significantly increased with the presence and severity of DR (NDR vs Pre-PDR,Pre-PDR vs PDR,P < 0.01 for each).Conclusions The severity and extent of CAs were significantly increased with the incidence and progression of DR,and much of CAs and DR could be still multifactoral with common pathway.%目的 采用64层螺旋CT血管造影(MDCT),探讨2型糖尿病患者冠状动脉粥样硬化(CAs)与糖尿病视网膜病变(DR)的关系.方法 诊断为CAs的2型糖尿病患者114例,无CAs的患者124例,受试者均进行眼底彩色照相

  9. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  10. Respiratory gated multidetector computed tomography: Applicable for diagnostic abdominal imaging?

    International Nuclear Information System (INIS)

    Purpose: To evaluate the ability and accuracy of a respiratory gated technique used with contrast enhanced MDCT of the upper abdomen with focus on diagnostic image quality and depiction of organs and major vessels. Materials and methods: Forty-five adult patients who were referred to our institution for follow-up dynamic contrast enhanced abdominal CT imaging were included in this study. Respiratory gated CT scans were performed with the use of a dedicated hardware. A multiphasic CT scan was performed for each patient. Respiratory gated images were obtained between early arterial and portal venous phases during free breathing. Images of respiratory gated (RG) and breathhold (BH) phases were compared qualitatively and quantitatively by two radiologists. Definitive statistical methods were used for evaluating the scoring data, while Mann Whitney U test was used for comparison. Statistical significance was accepted for p values <0.05. Results: Statistical significant difference was found for comparison of scores regarding luminal opacification and contoural integrity of intrahepatic vascular structures with scores of RG scans rated poor to moderate (e.g. 2.86 ± 1.07 for luminal opacification of intrahepatic portal veins as well as border detectability) in comparison to scores of BH scans rated good to excellent (e.g. 1.37 ± 1.31 for luminal opacification, 1.35 ± 1.28 for border detectability of intrahepatic portal veins, p < 0.001). Furthermore, statistical significant differences were found for general image noise levels (p < 0.001). Conclusions: Further technical advances of RG technique could enable routine use of this technique for selected patient groups.

  11. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  12. Multidetector row CT study of percutaneous transhepatic intrahepatic portosystemic shunt

    International Nuclear Information System (INIS)

    Objective: To investigate imaging features of the liver, portal vein and hepatic vein or transhepatic inferior vena cava in patients with severe liver cirrhosis in multidetector row computed tomography (MDCT), and assess the feasibility, safety and clinical significance of percutaneous transhepatic intrahepatic portosystemic, shunt (PTIPS). Methods: Fifty patients with severe liver cirrhosis confirmed by clinical data and imaging examination were enrolled in this study. Simulation of intrahepatic portosystemic shunt by percutaneous transhepatic, approach is as follows. The right midaxillary line (the eighth oi ninth intercostal space) was selected as puncture point A the right branch of portal vein was puncture point B, transhepatic inferior vena cava was puncture point C, and the distal part of right portal vein was D. A-B-C connection is simulated as percutaneous transhepatic puncture tract, C-B-D connection is simulated as portosystemic shunt tract. After tri-phase contrast-enhanced CT scanning, postprocessing images through multiple planner reconstruction (MPR) were obtained. The data were indicated statistically by x-bar±s. And 9.5% confidence interval for mean was calculated. Anatomic relationship among the right portal vein, transhepatic inferior vena cava, hepatic artery and bile duct were analyzed for all patients. Results: The length of the needle (A-B-C) is (145.7±14.8) mm. The curvature of the needle (the angle of A-B line and B-C line) is (145.0±9.9) . The length of transhepatic shunt tract (B-C) is (42.7±7.2) mm. The length of the shunt tract (C-B-D) is (117.7±11.6) mm; The angle of the shunt tract (the angle of B-C line and B-D line) is (108.5±5.9)°. In 24/50 patients, transhepatic inferior vena cava locate in the dorsal of the right portal vein, in 26/50 patients they are in the same plane. In all patients, the right branches of hepatic artery and bile duct locate in the ventral of the right portal vein. Conclusion: The procedure of PTIPS is

  13. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  14. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    International Nuclear Information System (INIS)

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  15. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    LENUS (Irish Health Repository)

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  16. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    OpenAIRE

    Symersky, P.; Budde, R. P. J.; Westers, P.; Mol, de, B.A.J.M.; Prokop, M

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stati...

  17. An F-statistic based multi-detector veto for detector artifacts in continuous-wave gravitational wave data

    OpenAIRE

    Keitel, D.; Prix, R.; Papa, M.; Siddiqi, M.

    2012-01-01

    Continuous gravitational waves (CW) are expected from spinning neutron stars with non-axisymmetric deformations. A network of interferometric detectors (LIGO, Virgo and GEO600) is looking for these signals. They are predicted to be very weak and retrievable only by integration over long observation times. One of the standard methods of CW data analysis is the multi-detector F-statistic. In a typical search, the F-statistic is computed over a range in frequency, spin-down and sky position, and...

  18. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  19. Controversies in imaging of hepatocellular carcinoma: multidetector CT (MDCT)

    OpenAIRE

    Silverman, Paul M.; Szklaruk, Janio

    2005-01-01

    Primary hepatocellular carcinoma (HCC) is a significant tumor worldwide and represents the most common primary hepatic neoplasm. Staging criteria are important for appreciation of timely work up of these neoplasms in contradiction with surgical colleagues. This article demonstrates the appearance of HCC on multiphasic, multidetector CT (MDCT) and relates these findings to current staging criteria. The variable appearance on different planes of contrast is critical to appreciate in staging thi...

  20. Study of Coronary Arteries by Means of Multidetector CT; Estudio de las arterias coronarias mediante tomografia computarizada multidetector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, G. C.; Costas, M. I.; Delgado, C.; Velasco, M.; Tardaguila, F. [Hospital POVISA. Vigo. Pontevedra (Spain)

    2004-07-01

    Radiological study of coronary arteries has undergone major advances,especially with the incorporation of new CT multidetectors which afford temporary spatial resolution sufficient for the acquisition of high-quality images and diagnoses concerning various coronary artery abnormalities. The technique is described in terms of both facilitating data within a procedure making use of beta-blockers to slow heart rate and postprocess image reconstruction. Accordingly, our experience with a 16-detector CT and its clinical applications are illustrated. (Author)

  1. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    Science.gov (United States)

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717). PMID:22787004

  2. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    Science.gov (United States)

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717).

  3. Multidetector CT in evaluating blood supply of hepatocellular carcinoma after transcatheter arterial chemoembolization

    Institute of Scientific and Technical Information of China (English)

    Yong-Song Guan; Xiao-Hua Zheng; Xiang-Ping Zhou; Juan Huang; Long Sun; Xian Chen; Xiao Li; Qing He

    2004-01-01

    AIM: To assess the value of multidetector-row computed tomography (MDCT) in choosing retreatment methods of hepatocellular carcinoma (HCC) through evaluating the blood supply of low-density area of HCC after transcatheter arterial chemoembolization (TACE).METHODS: Thirty-two patients with HCC after TACE treatment were examined by plain scanning and hepatic multidetector-row CT. The location of low-density area on plain scanning and the enhancement patterns on dynamic contrast-enhanced scanning were observed. At the same time, three-dimensional CT (3D CT) models of the volume rendering, curved multiplanar reformations, surface shaded display and maximum intensity projection reconstruction of the hepatic artery and portal vein were performed in 6 cases.RESULTS: In CT plain scanning data, low density areas of 32 cases of HCC after TACE treatment were divided into three types: peripheral, one-side-located and mixed types.In contrast-enhanced CT scans, the blood supply of lowdensity area was classified into four types: arterial blood supply (20 cases), portal blood supply (5 cases), arterial combined with portal blood supply (5 cases) and poor blood supply (2 cases). In 6 cases, the relationship between the low-density area and branches of hepatic artery as well as portal vein was shown by 3D CT.CONCLUSION: Hepatic MDCT is an effective method for evaluating the blood supply of low-density area and therapeutic effect of HCC after TACE treatment. Types of blood supply is helpful for the selection of retreatment.

  4. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  5. Adult Moyamoya disease: 320-Multidetector row CT for evaluation of revascularization in STA–MCA bypasses surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Bing; Xu, Bing; Liu, Qi; Hao, Qiang; Lu, Jianping, E-mail: cjr.lujianping@vip.163.com

    2013-12-01

    Purpose: To evaluate the utility of 320-multidetector row whole-brain computed tomography perfusion (WBCTP) and whole-head subtracted dynamic angiography (WHSDCTA) for assessing the revascularization of blood flow after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adults with Moyamoya disease (MD) in the short and long term. Patients and methods: 320-multidetector row WBCTP and WHSDCTA were applied in 20 patients with MD before and after surgery (for an average of 3 days and 3 months). The bypass arteries were investigated using WHSDCTA and compared with DSA. The regions of interests (ROIs) in the surgical and mirror sides of the cerebral cortex were drawn on a Vitrea Workstation. Cerebral blood volume (CBV), time to peak (TTP), cerebral blood flow (CBF), mean transit time (MTT), and delay time were recorded. Preoperative and postoperative perfusion parameters in the MCA distribution were compared using the paired t-test. Results: WHSDCTA could clearly demonstrate 24 bypass arteries in 26 arteries for 20 patients, results which were in accordance with the results of digital subtraction angiography (DSA). When comparing preoperative values to those within 3 days after surgery, only TTP and delay time were significantly different (P < 0.05). Values of CBV, TTP, CBF, delay time, and MTT 3 months after surgery were significantly different (P < 0.05) from those of preoperative perfusion. Conclusion: These data suggest that 320-multidetector row WBCTP and WHSDCTA can be used to evaluate the revascularization of blood flow after STA–MCA bypass surgery in patients with MD in the short and long term.

  6. Adult Moyamoya disease: 320-Multidetector row CT for evaluation of revascularization in STA–MCA bypasses surgery

    International Nuclear Information System (INIS)

    Purpose: To evaluate the utility of 320-multidetector row whole-brain computed tomography perfusion (WBCTP) and whole-head subtracted dynamic angiography (WHSDCTA) for assessing the revascularization of blood flow after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adults with Moyamoya disease (MD) in the short and long term. Patients and methods: 320-multidetector row WBCTP and WHSDCTA were applied in 20 patients with MD before and after surgery (for an average of 3 days and 3 months). The bypass arteries were investigated using WHSDCTA and compared with DSA. The regions of interests (ROIs) in the surgical and mirror sides of the cerebral cortex were drawn on a Vitrea Workstation. Cerebral blood volume (CBV), time to peak (TTP), cerebral blood flow (CBF), mean transit time (MTT), and delay time were recorded. Preoperative and postoperative perfusion parameters in the MCA distribution were compared using the paired t-test. Results: WHSDCTA could clearly demonstrate 24 bypass arteries in 26 arteries for 20 patients, results which were in accordance with the results of digital subtraction angiography (DSA). When comparing preoperative values to those within 3 days after surgery, only TTP and delay time were significantly different (P < 0.05). Values of CBV, TTP, CBF, delay time, and MTT 3 months after surgery were significantly different (P < 0.05) from those of preoperative perfusion. Conclusion: These data suggest that 320-multidetector row WBCTP and WHSDCTA can be used to evaluate the revascularization of blood flow after STA–MCA bypass surgery in patients with MD in the short and long term

  7. EUROGAM, a new gamma multidetector array: results and perspectives

    International Nuclear Information System (INIS)

    The new γ multidetector EUROGAM has been developed and built by a France - United Kingdom collaboration. Many experiments have performed with EUROGAM phase 1 at the Nuclear Structure Facility at Daresbury (U.K.) and recently with the phase 2 at the Vivitron at Strasbourg (France). Some of the most outstanding results concerning the superdeformation phenomenon and the oblate dipole bands will be discussed. GA.SP (Italy) and EUROGAM constitute the two first phases of the European Project EUROBALL. (author). 25 refs., 13 figs

  8. Pneumomediastinum on Multidetector CT: The Radiologic Signs and Underlying Disorders

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Soo Jin; Kim, Young Tong [Soonchunhyang University Chunan Hospital, Cheonan (Korea, Republic of)

    2011-02-15

    We can see the typical signs of pneumomediastinum on chest radiography and we can also see them on the multiplanar reformatted (MPR) image of multidetector CT (MDCT). MDCT can help to understand the anatomical feature of these signs and differentiate pneumomediastinum from pneumothorax, pneumopericardium and the Mach band effect. MDCT shows the peribronchovascular air, which reveals the Macklin effect, and it can also evaluate the underlying disorders that cause pneumomediastinum. The purpose of this pictorial essay is to inform physicians about the mechanism and anatomical features of pneumomediastinum, and to help them understand the imaging findings and underlying disorders of pneumomediastinum as seen on MDCT

  9. Radiological emergency room management with emphasis on multidetector-row

    International Nuclear Information System (INIS)

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted

  10. Value of Virtual Colonoscopy with 64 Row CT in Evaluation of Colorectal Cancer

    International Nuclear Information System (INIS)

    Virtual colonoscopy (VC) enables three-dimensional view of walls and internal lumen of the colon as a result of reconstruction of multislice CT images. The role of VC in diagnosis of the colon abnormalities systematically increases, and in many medical centers all over the world is carried out as a screening test of patients with high risk of colorectal cancer. We analyzed results of virtual colonoscopy of 360 patients with clinical suspicion of colorectal cancer. Sensitivity and specificity of CT colonoscopy for detection of colon cancers and polyps were assessed. Results of our research have shown high diagnostic efficiency of CT colonoscopy in detection of focal lesions in large intestine of 10 mm or more diameter. Sensitivity was 85.7%, specificity 89.2%. Virtual colonoscopy is noninvasive and well tolerated by patients imaging method, which permits for early detection of the large intestine lesions with specificity and sensitivity similar to classical colonoscopy in screening exams in patients suspected for colorectal cancer. Good preparation of the patients for the examination is very important for proper diagnosis and interpretation of this imaginge procedure

  11. Toroid cavity/coil NMR multi-detector

    Science.gov (United States)

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  12. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an

  13. Comparison of Multidetector CT Angiographic Findings with Operative Findings of Renal Vasculature in Living Renal Donors

    Directory of Open Access Journals (Sweden)

    Soodeh Sagheb

    2010-05-01

    Full Text Available Background/Objective: In kidney transplantation, decision about donation of the proper kidney is not the same between different surgeons. One of the most important factors for choosing the best kidney for transplantation is a simple vasculature anatomy and a kidney without abnormalities. In laparoscopic nephrectomy, the left kidney is preferred, because it has a longer renal vein and the renal artery is not behind the inferior vena cava (IVC. In other situations, in order to reduce the vascular morbidity of the surgery, nephrectomy is on the side which has a simpler vascular anatomy."nAssessment of renal vasculature of a live donor with noninvasive techniques is a necessity for live donors. For delineation of vascular anomalies of the kidney as well as urinary system abnormalities, Multi-Detector CT seems to be an excellent method for evaluation."nPatients and Methods: In this study, 59 live donors were assessed with multi-detector CT angiography. After injection of 80 ml contrast media, we acquired CT images with 0.6 mm slice thickness. Finally, processing and three dimensional reconstructions were performed and the accessory arteries, early branching of the main renal artery, the number of main renal vessels and the ureters were assessed. Findings were compared with the nephrectomy results."nResults: In multi slice CT angiography the prevalence of accessory renal artery was 3.4% with 98% accuracy, early branching of the main renal artery was 8.4% with 100% accuracy. Multiplicity of renal veins was seen in 8.4% of donors with 98% accuracy. Duplicated ureter was not seen in any of the donors."nDiscussion: The accuracy of CT angiography is 95% for depicting accessory renal artery and multiple renal artery and 100% for early branching. These results were comparable with the findings in conventional angiography and the studies showed that this method is more valuable in comparison with MR angiography and digital subtraction angiography. Also, it is

  14. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    International Nuclear Information System (INIS)

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  15. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L. [Kantonsspital, Institute of Radiology, Winterthur (Switzerland); Patak, Michael A. [Kantonsspital, Institute of Radiology, Winterthur (Switzerland); Inselspital, University Hospital of Bern, Institute of Diagnostic, Interventional and Paediatric Radiology, Bern (Switzerland); Erturk, Sukru M. [Sisli Etfal Education and Research Hospital, Department of Radiology, Istanbul (Turkey)

    2008-09-15

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  16. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma

    Institute of Scientific and Technical Information of China (English)

    Luigi; Camera; Rosa; Severino; Antongiulio; Faggiano; Stefania; Masone; Gelsomina; Mansueto; Simone; Maurea; Rosa; Fonti; Marco; Salvatore

    2014-01-01

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography(CT) or magnetic resonance(MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved bysomatostatin-receptor scintigraphy(SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR(Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT(Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure(3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  17. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    International Nuclear Information System (INIS)

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  18. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  19. A comparative review of multidetector CT angiography and MRI in the diagnosis of jugular foramen lesions

    Energy Technology Data Exchange (ETDEWEB)

    Christie, A., E-mail: andychristie90@hotmail.co [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom); Teasdale, E. [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom)

    2010-03-15

    Aim: To compare the efficiency of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the diagnosis of jugular foramen lesions. Materials and methods: The imaging of 15 patients with tumours predominantly occurring at the jugular foramen was retrospectively reviewed, with postoperative pathology data available for 11 patients. MDCT was performed at arterial phase and MRI with standard sequences and contrast enhancement. All imaging was blindly re-reported by an experienced neuroradiologist. Results: Pathology reported six glomus jugulare tumours and five neuromas, which were all correctly diagnosed using MDCT. A confident diagnosis was also made in the remaining four cases based on the pattern of enhancement. Only glomus tumours enhanced in the arterial phase. Overall, MRI was used to make a confident diagnosis in eight patients. One showed no enhancement and was correctly diagnosed as a neuroma, and seven demonstrated the tumour flow voids characteristic of a glomus tumour. The remaining seven cases all showed a similar enhancement pattern and could not be confidently differentiated between a neuroma or a glomus tumour. MDCT angiography enabled a confident assessment of the jugular vein in all cases, but MRI was inconclusive in a third of cases. Also, in the nine cases of glomus tumour diagnosed using MDCT, an enlarged feeding artery was identified in eight patients. Conclusion: MDCT is more accurate than MRI in diagnosing glomus tumours, and in particular, neuromas. It also offers valuable preoperative vascular information to the surgeon.

  20. Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography

    Energy Technology Data Exchange (ETDEWEB)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas Horst; Guenther, Rolf W.; Wildberger, Joachim Ernst [University Hospital, University of Technology (RWTH), Department of Diagnostic Radiology, Aachen (Germany); Weiss, Claudia [RWTH Aachen, Institute of Medical Statistics, Aachen (Germany); Schoepf, U. Joseph [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Leidecker, Christianne [Institute of Medical Physics, University of Erlangen, Erlangen (Germany)

    2006-02-01

    The aims of this study were to optimize image quality for indirect CT venography (sequential versus spiral), and to evaluate different image reconstruction parameters for patients with suspected deep venous thrombosis (DVT). Fifty-one patients (26/25 with/without DVT) were prospectively evaluated for pulmonary embolism (PE) with standard multidetector-row computed tomography (MDCT) protocols. Retrospective image reconstruction was done with different slice thicknesses and reconstruction increments in sequential and spiral modes. All reconstructions were read for depiction of DVT and to evaluate best reconstruction parameters in comparison with the thinnest reconstruction (''gold standard''). Image noise and venous enhancement were measured as objective criteria for image quality. Subjective image quality was rated on a four-point scale. Effective dose was estimated for all reconstructions. In sequential 10/50 reconstruction DVT was completely detected in 13/26 cases, partially in 10/26 cases and was not detected at all in 3/26 cases, and 15/26, 9/26 and 2/26 cases for the 10/20 reconstruction, respectively. DVT was completely detected in all spiral reconstructions. Image noise ranged between 14.8-29.1 HU. Median image quality was 2. Estimated effective dose ranged between 2.3 mSv and 11.8 mSv. Gaps in sequential protocols may lead to false negative results. Therefore, spiral scanning protocols for complete depiction of DVT are mandatory. (orig.)

  1. Multidetector CT in the evaluation of potential living donors for liver transplantation.

    Science.gov (United States)

    Alonso-Torres, Ana; Fernández-Cuadrado, Jaime; Pinilla, Inmaculada; Parrón, Manuel; de Vicente, Emilio; López-Santamaría, Manuel

    2005-01-01

    Living donor liver transplantation is increasingly being used to help compensate for the increasing shortage of cadaveric liver grafts. However, the extreme variability of the hepatic vascular systems can impede this surgical procedure. Evaluation of potential living donors was conducted in which a two-detector-row computed tomographic (CT) scanner was used to obtain arterial phase and portal dominant phase images following the intravenous injection of contrast material, after which three-dimensional maximum-intensity-projection and volume-rendered images were created. The vascular anatomy was evaluated, with special attention given to the origin and course of the artery to segment IV and the presence of variants, especially those considered relative or absolute contraindications for donation, those requiring reconstruction, or those potentially altering the surgical approach. In addition, graft and remnant liver volumes were determined and the liver parenchyma evaluated. Multidetector CT is proving to be valuable in the evaluation of potential living liver donors, contributing to donor safety and providing comprehensive information about the hepatic vascular anatomy, the liver parenchyma, and graft and remnant liver volume. This information is critical in choosing the most suitable potential donor, in surgical planning, and in obtaining an optimal graft that maintains the balance between blood supply and venous drainage. PMID:16009821

  2. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  3. Optimised low-dose multidetector CT protocol for children with cranial deformity

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Jose Luis [Complejo Hospitalario Universitario de Vigo, Department of Radiology, Vigo, Pontevedra (Spain); Pombar, Miguel Angel [Complejo Hospitalario Universitario de Santiago, Department of Radiophysics, Santiago de Compostela, La Coruna (Spain); Pumar, Jose Manuel [Complejo Hospitalario Universitario de Santiago, Department of Radiology, Santiago de Compostela, La Coruna (Spain); Campo, Victor Miguel del [Complejo Hospitalario Universitario de Vigo, Department of Public Health, Vigo, Pontevedra (Spain)

    2013-08-15

    To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity. Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used. The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT. A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. (orig.)

  4. Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study

    OpenAIRE

    Yang, Ching-Ching; Chen, Fong-Lin; Lo, Yeh-Chi

    2016-01-01

    Purpose The aim of this study was to improve the image quality of cone-beam computed tomography (CBCT) mounted on the gantry of a linear accelerator used in radiation therapy based on the image information provided by planning multi-detector CT (MDCT). Methods MDCT-based shading correction for CBCT and virtual monochromatic CT (VMCT) synthesized using the dual-energy method were performed. In VMCT, the high-energy data were obtained from CBCT, while the low-energy data were obtained from MDCT...

  5. Computed tomography of acute pulmonary embolism: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Meinel, Felix G.; McQuiston, Andrew D.; Ravenel, James G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Multidetector computed tomography (CT) plays an important role in the detection, risk stratification and prognosis evaluation of acute pulmonary embolism. This review will discuss the technical improvements for imaging peripheral pulmonary arteries, the methods of assessing pulmonary embolism severity based on CT findings, a multidetector CT technique for pulmonary embolism detection, and lastly, how to avoid overutilization of CT pulmonary angiography and overdiagnosis of pulmonary embolism. (orig.)

  6. Computed tomography of the intestinal tract, usage, advantages and disadvantages of this metod

    OpenAIRE

    SMOLÁKOVÁ, Eva

    2007-01-01

    In presented essay author tries to offer comprehensive overview of possibilities of computer tomography (CT) in examination of the intestinal tract at her radiologic department. Introduction of Multidetector CT represents outstanding advance in spatial resolution in z - axis and accelerated data acquisition wihout increase of radiation dose. All these advantages of Multidetector CT project strongly onto examination of the intestines. At author´s department CT enterography and CT colonography ...

  7. Dose-reduced 16-slice multidetector-row spiral computed tomography in children with bronchoscopically suspected vascular tracheal stenosis - initial results; Dosisreduzierte 16-Schicht-Multidetektor-Spiralcomputertomographie bei Saeuglingen und Kleinkindern mit bronchoskopischem Verdacht auf vaskulaer bedingte Trachealstenosen - erste klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, D.; Wildberger, J.E.; Das, M.; Hohl, C.; Mahnken, A.; Guenther, R.W.; Staatz, G. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik; Schnoering, H.; Vazquez-Jimenez, J. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Kinderherzchirurgie

    2006-04-15

    Purpose: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis. Materials and Methods: 12 children (4 days to 3 years, 1.2-13.5 kg body weight) were examined using i.v. contrast-enhanced 16-slice MDCT (SOMATOM Sensation 16, Forchheim, Germany) without breath-hold and under sedation (11/12). All MDCTs were performed with a dose reduction. The beam collimation was 16 x 0.75 mm, except in the case of one child. MPRs along the tracheal axis in the x-, y- and z-directions and volume-rendering-reconstructions (VRTs) were calculated based on a secondary raw data set in addition to conventional axial slices. 2 radiologists used a three-point grade scale to evaluate the image quality, motion, and contrast media artifacts as well as the usefulness of the 2D- and 3D-reconstructions for determining the diagnosis. Statistical analysis was performed on the basis of a Kappa test. Results: In all cases the cause of the fiberoptic bronchoscopically suspected tracheal stenosis was revealed: compression due to the brachiocephalic trunk (n=7), double aortic arch (n=2), lusorian artery (n=1), vascular compression of the left main bronchus (n=2). In 3 patients further thoracic anomalies, such as tracheobronchial (n=2), and vascular (n=2) and vertebral (n=1) anomalies were found. The attenuation in the anomalous vessels was 307{+-}140 HU. The image noise was 9.8{+-}1.9 HU. The mean dose reduction was 82.7{+-}3.2% compared to a standard adult thoracic CT. All examinations were rated as diagnostically good (median 1, range 1, k=1). 3D images did not show any stair artifacts (median 2, range 1-2, k=1). The image noise was minor to moderate and hardly any motion artifacts were seen (median 1, range 1-2, k=0.8). Contrast media artifacts were rated zero to minor (median 1.5, range 1-2, k=0.676). MPRs (median 1, range 1, k=1) and VRTs

  8. Multidetector 4π INDRA Geometry simulation and silicon detectors study

    International Nuclear Information System (INIS)

    INDRA is a 4π detector of charged particles (p,d,t,α) and fragments (at least Z = 30) with an excellent space coverage (>80%). It consists of an assembly of 96 ionization chambers, 180 Silicon detectors (30 0), 324 caesium iodide scintillation detectors, and 12 NE102/NE115 scintillation detectors (200) distributed on 17 concentric rings. The detection thresholds are low and the dynamic range in energy is large (minimum 1000). A simulation of INDRA has been carried out in order to assist its technical realisation, the preparation of some experiments, and to guide the analysis of the experimental results according to the most frequently demanded areas of the multidetector. Specifically, identification matrices, both ionization chamber - silicon and caesium iodide - silicon, have been simulated to investigate these factors. The construction of the ring 4-5 (700) defines and suggests solutions for the major problems that will be encountered during the construction of the other rings, especially with the mechanical mounting of the silicon detectors. In addition, the study of the electronics associated with the silicon detectors has shown the necessity: - to devise specific amplifiers, on account of the excessive electronic noise of the amplifiers usually used. - to modify the manufacturing criteria of some of the silicon detectors manufacturing criterium (the metallization thickness on the side N+, the choice of high resistivities)

  9. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  10. Multidetector row-CT in evaluation of living renal donors

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ji-qing; HU Xiao-peng; WANG Wei; LI Xiao-bei; YIN Hang; ZHANG Xiao-dong

    2010-01-01

    Background Multidetector-row CT (MDCT) has been evolving to the standard evaluating method of potential living donor in most centers, and can provide excellent details for selecting candidates and determining surgical technique.This study aimed to assess the value of MDCT in evaluation of the anatomy of living kidney donors and to reveal the prevalence of renal vascular variations in a Chinese population.Methods One hundred and four potential donors underwent MDCT and the data sets were post-processed for reformatted images with various techniques, such as maximum intensity projection (MIP), a volume-rendering technique (VR), and multiplanar reformation (MPR). Donor nephrectomies were performed on 97 candidates after MDCT evaluation with the findings during surgery constituting the standard of reference. Resulting MDCT images were compared with actual anatomy found during surgery. Results The MDCT images accurately displayed the anatomic structure of the main renal arteries and veins as well as the upper ureters, except in one case with horseshoe kidney. The prevalence of accessory arteries revealed in images was 27.2% (28/103) and early branching was found in 12.6% (13/103). Compared with findings during surgery, the detection of accessory arteries in MDCT images was 85.7% (6/7), and the detection of larger accessory arteries (>1.5 mm in diameter) was 100%. Detection of early branching was 100%.Conclusion MDCT helps accurately evaluate the renal anatomy of potential donors thus facilitating the planning of surgery.

  11. Computed tomographic angiography in tetralogy of Fallot.

    Science.gov (United States)

    Kasar, Pankajkumar Ashok; Ravikumar, Radhakrishnan; Varghese, Roy; Kotecha, Monika; Vimala, Jesudian; Kumar, Raghavan Nair Suresh

    2011-10-01

    Echocardiography is often inadequate for imaging tetralogy of Fallot, prompting cineangiography. This study prospectively evaluated multidetector computed tomographic angiography for preoperative evaluation of tetralogy of Fallot in 112 consecutive patients. Forty-eight had nonconfluent or hypoplastic pulmonary arteries (mean z-score, -2; range, -11.1-0.13) permitting only palliative or no surgery; 64 had adequate pulmonary artery anatomy (mean z-score, 0.59; range, -2.53-3.4) allowing total repair. The surgical data of 50 patients who underwent total correction were compared with transthoracic echocardiography and multidetector computed tomographic angiography findings. Multidetector computed tomographic angiography tended to reveal unsuspected collaterals and coronary abnormalities besides outlining the right ventricular outflow tract and pulmonary artery branches. The branch pulmonary artery diameter z-score was the most important determinant of surgical strategy, with the worst figures being associated with no surgical options or palliative surgery, and the best figures leading to corrective surgery. The mean radiation dose was 3.45 mSv. Multidetector computed tomographic angiography is a powerful supplement to echocardiography in the preoperative evaluation of tetralogy of Fallot.

  12. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...

  13. 64排128层螺旋CT图像重建技术对胆脂瘤型中耳炎的术前评估价值%The Value of Preoperative Assessment about Otitis Media with Cholesteatoma by Image Reconstruction of 64-Multidetector 128-Slice Computer Tomography

    Institute of Scientific and Technical Information of China (English)

    相丽; 郑穗生

    2011-01-01

    Obiective To explore the advantages and disadvantages of post-processing techniques of MSCT to the manifestation of bone destruction in ears with otitis media with cholesteatoma. Materials and Methods fmage reconstruction of 64-multidetector 128-slice CT were performed to middle and internal ears of 42 ears with otitis media with cholesteatoma in different ways. The images were compared to intraoperative findings, and the concordance of the two underwent Kappa test. SPSS was used to deal with the results. High concordance was defined as Kappa ≥0.75. Acceptable concordance was defined as 0. 41/Ukappa"00.75. Low concordance was defined as Kappa"U0.4. Results Kappa values of head of malleus, long crus of incus, short crus of incus, body of incus body, bone destruction of meningeal board, aditus ad antrum expanding and structure defects of horizontal segment of facial nerve canal were greater than 0.75L?Kappa values of handle of malleus, incudomelleolar joints, horizontal and labyrinthin segment of facial nerve canal, semicircular canal, scutum, bone wall of sigmoid sinus and bone destruction of labyrinth were between 0.4 and 0.75, but Kappa values of incudostapedial joint, anterior crus of stapes, posterior crus of stapes and bone destruction of footplate of stapes were less than 0.4. Conclusions Images of bone destruction in middle and internal ears with otitis media with cholesteatoma have important reference value for the operation.%目的 探讨MSCT后处理技术对胆脂瘤型中耳炎骨质破坏情况显示的优劣势.材料与方法 采用64排128层螺旋CT对42耳胆脂瘤型中耳炎中耳及内耳结构进行多种方式重建,结果与术中所见对照,Kappa检验二者的一致性,采用SPSS11.0软件包处理,规定 Kappa值大于或等于0.75为两者有很高的一致程度,其值在0.4-0.75说明一致程度尚可.小于0.4则说明一致程度不够理想.结果 锤骨头、砧骨长脚、砧骨短脚、砧骨体、脑膜板骨壁骨质破坏

  14. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    International Nuclear Information System (INIS)

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  15. Search for continuous gravitational waves: metric of the multi-detector F-statistic

    OpenAIRE

    Prix, R.

    2007-01-01

    We derive the parameter-space metric of the multi-detector F-statistic, which is the optimal detection statistic for continuous gravitational waves in stationary Gaussian noise. We find that there is a family of F-statistic metrics, parametrized by the (unknown) amplitude parameters. We explicitly derive the maximal mismatch-range of this metric family, and we introduce a corresponding "average" F-metric. We show that the multi-detector metric consists of noise-weighted averages of single-det...

  16. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  17. Multidetector CT and MRI in diseases of the GI tract

    International Nuclear Information System (INIS)

    With the introduction of spiral scanning then multidetector technologies, the accuracy for diagnosing digestive tract diseases with CT has been highly improved, and CT is used more and more in the evaluation of patients with suspected gastrointestinal disorders. CT is able to demonstrate both the intramural and the extra-mural components of the disease, and has a major role in the preoperative staging and the follow-up Improvements of CT protocols, such as CT-enteroclysis, or multiplanar 2D and 3D post-processing, including now techniques for 'virtual endoscopy', lead to discuss new indications in which CT could now compete with conventional X-rays series and video-endoscopy. This precise study of the digestive wall, the peri-digestive fat, the digestive tract blood supply, may be performed by MRI, under the condition of access to high level machines and standardized protocols. MR-enteroclysis and MR-virtual colonoscopy could be performed with much lower risk for the patient, in terms of radiation dose or contrast adverse effects. Endo-luminal coils should give to MR an ultra-high resolution for analysing the different layers of the gastrointestinal wall. Learning objectives: to review how to perform CT and MRI protocols for digestive tract imaging, to recognize the CT arid MR patterns of the main digestive tract diseases, to discuss the value, limits and role of CT and MR in digestive tract diseases, to discuss the potential role of CT and MR new technological developments for digestive tract imaging in the upcoming future Conclusion: CT is nowadays a modality of choice for digestive imaging. Improvements in technologies and indications, the necessary discussion of the risks and benefits for the patient should let the radiologists consider MRI in gastrointestinal disorders as an important part of the routine activity in clinical MRI. (authors)

  18. Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Cotroneo, A.R.; Giammarino, A. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Spigonardo, F. [Department of Vascular Surgery, University ' G. D' Annunzio' , Chieti (Italy); Storto, M.L. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2011-07-15

    Purpose: To investigate the possibility of reducing radiation dose exposure while maintaining image quality using multidetector computed tomography angiography (MDCTA) with high-concentration contrast media in patients undergoing follow-up after endovascular aortic repair (EVAR) to treat abdominal aortic aneurysm. Materials and methods: In this prospective, single center, intra-individual study, patients underwent two consecutive MDCTA scans 6 months apart, one with a standard acquisition protocol (130 mAs/120 kV) and 120 mL of iomeprol 300, and one using a low dose protocol (100 mAs/80 kV) and 90 mL of iomeprol 400. Images acquired during the arterial phase of contrast enhancement were evaluated both qualitatively and quantitatively for image noise and intraluminal contrast enhancement. Results: Thirty adult patients were prospectively enrolled. Statistically significantly higher attenuation values were measured in the low-dose acquisition protocol compared to the standard protocol, from the suprarenal abdominal aorta to the common femoral artery (p < 0.0001; all vascular segments). Qualitatively, image quality was judged significantly (p = 0.0002) better with the standard protocol than with the low-dose protocol. However, no significant differences were found between the two protocols in terms of contrast-to-noise ratio (CNR) (13.63 {+-} 6.97 vs. 11.48 {+-} 8.13; p = 0.1058). An overall dose reduction of up to 74% was observed for the low-dose protocol compared with the standard protocol. Conclusion: In repeat follow-up examinations of patients undergoing EVAR for abdominal aortic aneurysm, a low-dose radiation exposure acquisition protocol provides substantially reduced radiation exposure while maintaining a constant CNR and good image quality.

  19. Paratracheal air cysts: prevalence and correlation with lung disease using multi-detector CT

    International Nuclear Information System (INIS)

    The purpose of this study was to determine the prevalence of paratracheal air cysts (PACs), their correlation with different lung diseases and their connection with the trachea by chest multi detector computed tomography (MDCT). We retrospectively reviewed chest MDCT images of 8240 consecutive patients obtained from January 2010 to December 2011 with a 16-detector multi-detector CT scanner. PACs were assessed for prevalence, location, level, size and the presence of visible communication with the trachea. MDCT diagnoses were classified as normal, primary or metastatic malignancies, chronic obstructive pulmonary disease (COPD), pneumonia and other lung diseases. We randomly selected 330 patients who had no visible PACs for the control group. We evaluated the associations between patients' demographic findings (age and sex), MDCT findings of lung and the presence of PACs. The findings of the PACs and control groups were compared. Statistical analysis used chi-squared test and Mann - Whitney U-test for evaluation. PACs were presented in 301 patients (4%); 204 men and 97 women, ranging in age from 14 to 91 years (median=57 years). There was no significant difference in the presence of PACs by age (P>0.05). Male subjects showed higher prevalence (P=0.005). Fifty PACs (16.6%) showed communication with the trachea or main bronchus. Although the relation between COPD and PACs was statistically significant (P<0.001), there was no relation between primary or metastatic malignancies, pneumonia and other lung diseases and PACs. PACs are common in MDCT and should not be misdiagnosed as pneumomediastinum. It should be kept in mind that PACs may be associated with COPD.

  20. A project to design a software package for reporting multidetector CT (MDCT) doses

    International Nuclear Information System (INIS)

    Computed tomography (CT) has established itself as one of the most significant diagnostic technologies. The advent of the multidetector CT (MDCT) has made it possible to capture images to create 4D motion images for cardiac and respiratory diseases. As its usage grows, more concerns about the potential radiation risk to patients associated with various CT scanning protocols have raised from the medical imaging community and patients. This paper describes the effort to develop a modern software package to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. Original dose data were derived from a large number of Monte Carlo (MC) simulations based both on the ICRP 60 and ICRP 103 tissue-weighting coefficient using MCNPX v2.5, involving detailed CT scanner models and anatomically realistic phantoms. Detailed CT scanner X-ray sources and protocols are considered in the Monte Carlo simulations. Several of CT scanner series and different operated tube voltage have been taken into consideration. The RP1 Pregnant Women (RP1-P3, -P6 and -P9) and RP1 Adult Male (RPI-AM) and Adult Female (RPI-AF) are utilized as the phantom models. The software is being developed using the Visual C.NET platform with a graphical user interface (GUI) designed to allow a user to specify the patient type, body scan region, and scanner operating parameters. Using the object-oriented programming technology, 3D phantoms are displayed interactively to improve the user interaction with software functions. The organ dose and effective dose are rapidly archived and reported in the software according to the user-specified protocols. (authors)

  1. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    International Nuclear Information System (INIS)

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44–50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  2. Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

    Science.gov (United States)

    Badawi-Fayad, J; Yazbeck, C; Balzeau, A; Nguyen, T H; Istoc, A; Grimaud-Hervé, D; Cabanis, E- A

    2005-12-01

    The purpose of this study was to determine the optimal tube current setting and scanning mode for hominid fossil skull scanning, using multi-detector row computed tomography (CT). Four fossil skulls (La Ferrassie 1, Abri Pataud 1, CroMagnon 2 and Cro-Magnon 3) were examined by using the CT scanner LightSpeed 16 (General Electric Medical Systems) with varying dose per section (160, 250, and 300 mAs) and scanning mode (helical and conventional). Image quality of two-dimensional (2D) multiplanar reconstructions, three-dimensional (3D) reconstructions and native images was assessed by four reviewers using a four-point grading scale. An ANOVA (analysis of variance) model was used to compare the mean score for each sequence and the overall mean score according to the levels of the scanning parameters. Compared with helical CT (mean score=12.03), the conventional technique showed sustained poor image quality (mean score=4.17). With the helical mode, we observed a better image quality at 300 mAs than at 160 in the 3D sequences (P=0.03). Whereas in native images, a reduction in the effective tube current induced no degradation in image quality (P=0.05). Our study suggests a standardized protocol for fossil scanning with a 16 x 0.625 detector configuration, a 10 mm beam collimation, a 0.562:1 acquisition mode, a 0.625/0.4 mm slice thickness/reconstruction interval, a pitch of 5.62, 120 kV and 300 mAs especially when a 3D study is required. PMID:16211320

  3. Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca [University of Cagliari, Department of Radiology, Policlinico Universitario, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Policlinico Universitario, Department of Vascular Surgery, Cagliari (Italy); Mallarini, Giorgio [University of Cagliari, Department of Radiology, Policlinico Universitario, Cagliari (Italy); Ospedale San Giovanni di Dio, Institute of Radiology, Cagliari (Italy)

    2010-02-15

    Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value {+-} standard deviation and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 {+-} 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT. (orig.)

  4. Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

    International Nuclear Information System (INIS)

    Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value ± standard deviation and were compared using the Mann-Whitney U test. A p value <0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 ± 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT. (orig.)

  5. Setting graphic software for data examination of multidetector used in heavy ions physic

    International Nuclear Information System (INIS)

    In this work, the first chapter presents both the multidetectors of the vacuum chamber NAUTILUS, from a geometrical and parametrical point of view and the manual analysis phase. The second part deals with the main notions of the language Graphical Kernel System. Finally, the third chapter is a presentation of the different graphical programs written in order to accelerate and rationalize the analysis phase

  6. Pancreatic pseudoaneurysm in a child with hereditary pancreatitis: diagnosis with multidetector CT angiography

    International Nuclear Information System (INIS)

    Pseudoaneurysm formation is a serious vascular complication of pancreatitis. It most commonly affects splenic and gastroduodenal arteries. We report a rare case of superior mesenteric artery pseudoaneurysm in a child with hereditary pancreatitis. Multidetector CT angiography allowed the comprehensive assessment of the aneurysm and allowed accurate surgical planning obviating the need for catheter angiography. (orig.)

  7. Application of multi-detector row helical scanning to postmyelographic CT

    International Nuclear Information System (INIS)

    The advent of a multi-detector row helical CT has made it possible to attain images over a broader area with good spatial resolution. We assessed whether postmyelographic CT scans obtained using this system provided more information than conventional imaging techniques. Postmyelographic CT scans were preoperatively obtained in 46 patients using a multi-detector row helical CT system. Reconstructed images in the sagittal and coronal planes in all patients and curved reformation images along the dural sac in 37 patients were compared with myelograms and conventional postmyelographic CT scans. In 34 patients comparison was also made with MR images. The multi-detector row CT images demonstrated deformities of the dural sac more clearly than the other modalities in 39 of the 46 patients. They also provided the best visualization of nerve root abnormalities in 24 of the 46 patients and clearly revealed the presence of spurs in all 22 patients with spinal canal stenosis. Postmyelographic CT scans made using a multi-detector row helical CT system provide more information on the dural sac, nerve sleeves, and their contents than other imaging techniques. (orig.)

  8. Study of statistical properties of hybrid statistic in coherent multidetector compact binary coalescences search

    Science.gov (United States)

    Haris, K.; Pai, Archana

    2016-05-01

    In this article, we revisit the coherent gravitational wave search problem of compact binary coalescences with multidetector network consisting of advanced interferometers like LIGO-Virgo. Based on the loss of the optimal multidetector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio (MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives few false alarms compared to the multidetector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We demonstrate that, for a LIGO-Virgo network and binary inclination ɛ 11 0 ° , the hybrid statistic captures more than 98% of the network optimum matched filter SNR with a low false alarm rate. The Monte Carlo exercise with two distributions of incoming inclination angles—namely, U [cos ɛ ] and a more realistic distribution proposed by B. F. Schutz [Classical Quantum Gravity 28, 125023 (2011)]—are performed with the hybrid statistic and give approximately 5% and 7% higher detection probabilities, respectively, compared to the two stream multidetector MLR statistic for a fixed false alarm probability of 1 0-5.

  9. Multi-detector setup for nuclear astrophysical reaction studies on the low energy ion beam

    International Nuclear Information System (INIS)

    The multi-detector setup assembled on the basis of the ion beam from 'SOKOL' electrostatic accelerator is described. The setup allows one to measure three various spectra in a single experiment: prompt gamma-quanta from nuclear reactions, positrons from the decays of radioactive nuclei formed in the reactions and coincidence spectrum of annihilation gamma-quanta. (authors)

  10. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  11. Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Ja [Graduate School of Clinical Dentistry, Hallym University, Seoul (Korea, Republic of); Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-03-15

    This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

  12. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    International Nuclear Information System (INIS)

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  13. Lung Nodule Detection in Screening Computed Tomography

    CERN Document Server

    Gori, I; Cerello, P; Cheran, S C; De Nunzio, G; Fantacci, M E; Kasae, P; Masala, G L; Pérez-Martínez, A; Retico, A

    2007-01-01

    A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

  14. Deepgoing study on intrathoracic tuberculous lymphadenitis in adults using multidetector CT

    Institute of Scientific and Technical Information of China (English)

    LUO Ming-yue; LIU Li; LAI Li-sha; DONG Yun-xu; LIANG Wen-wei; QIN Jie

    2010-01-01

    Background Studies on intrathoracic tuberculous lymphadenitis in adults are confined to the preliminary CT findings with ordinary CT and ordinary spiral CT.There has been no deepgoing study of multidetector CT to date.Multidetector CT could contribute to better imaging of intrathoracic tuberculous lymphadenitis in adults.The purpose of this study was to explore the multidetector CT features of intrathoracic tuberculous lymphadenitis in adults, and the correlation with clinical symptoms and pathologic changes.Methods Multidetector CT findings from 42 consecutive adult patients with intrathoracic tuberculous lymphadenitis were analyzed retrospectively with regard to locations, sizes, numbers, shapes, margins, and densities reviewing precontrast and enhanced images.CT results were correlated with clinical symptoms and pathologic results (n=37).Results One hundred and eighty-five intrathoracic lymph nodes that had tuberculous lymphadenitis in 42 patients were distributed mainly in regions 4R (n=37), 2R (n=33), 7 (n=31) and 10R (n=21), more than 2 regions were implicated in 34 patients.One hundred and twenty-two (72.2%) of the tuberculous lymphadenitis without confluence were oval or round with clear margins.On precontrast scanning, 78.4% of tuberculous lymphadenitis had a homogeneous density.Seven enhancement patterns were demonstrated in 169 tuberculous lymphadenitis from 37 patients with pathologic results:homogeneous enhancement with no clinical symptom (n=12), corresponded pathologically to tuberculous hyperplasia without caseous necrosis; heterogeneous enhancement with a small central no enhancement area, slight clinical symptoms (n=22), tuberculous granulomas with a little caseous necroses; peripheral irregular thick wall enhancement with a central area with no enhancement, slight clinical symptoms (n=52), tuberculous granulomas with some caseous necroses in the center; peripheral thin rim enhancement with a central area having no enhancement, moderate clinical

  15. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H;

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary ...

  16. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    International Nuclear Information System (INIS)

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 ± 0.31 mm on digital subtraction angiography (DSA), 0.93 ± 0.20 mm on CTA using B30, 1.18 ± 0.27 mm on CTA using B50, and 1.29 ± 0.29 mm on CTA using B60. The mean ALN was 55.7 ± 6.0% on CTA using B30, 43.8 ± 7.5% on CTA using B50, and 38.7 ± 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  17. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Lim, Yeon Soo; Lee, Youn Joo; Yoo, Won Jong; Sung, Mi Sook (Dept. of Radiology, Bucheon St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Bucheon (Korea, Republic of)), email: wjyu@catholic.ac.kr; Kim, Bum Soo (Dept. of Radiology, Seoul St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of))

    2012-05-15

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 +- 0.31 mm on digital subtraction angiography (DSA), 0.93 +- 0.20 mm on CTA using B30, 1.18 +- 0.27 mm on CTA using B50, and 1.29 +- 0.29 mm on CTA using B60. The mean ALN was 55.7 +- 6.0% on CTA using B30, 43.8 +- 7.5% on CTA using B50, and 38.7 +- 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  18. Investigating the low-dose limits of multidetector CT in lung nodule surveillance.

    Science.gov (United States)

    Paul, N S; Siewerdsen, J H; Patsios, D; Chung, T B

    2007-09-01

    The purpose of this study was to evaluate the factors limiting nodule detection in thoracic computed tomography (CT) and to determine whether prior knowledge of nodule size and attenuation, available from a baseline CT study, influences the minimum radiation dose at which nodule surveillance CT scans can be performed while maintaining current levels of nodule detectability. Multiple nodules varying in attenuation (-509 to + 110 HU) and diameter (1.6 to 9.5 mm) were layered in random and ordered sequences within 2 lung cylinders made of Rando lung material and suspended within a custom-built CT phantom. Multiple CT scans were performed at varying kVp (120, 100, and 80), mA (200, 150, 100, 50, 20, and 10), and beam collimation (5, 2.5, and 1.25 mm) on a four-row multidetector scanner (Lightspeed, General Electric, Milwaukee, WI) using 0.8 s gantry rotation. The corresponding range of radiation dose over which images were acquired was 0.3-26.4 mGy. Nine observers independently performed three specific tasks, namely: (1) To detect a 3.2 mm nodule of 23 HU; (2) To detect 3.2 mm nodules of varying attenuation (-509 to -154 HU); and (3) To detect nodules varying in size (1.6-9 mm) and attenuation (-509 to 110 HU). A two-alternative forced-choice test was used in order to determine the limits of nodule detection in terms of the proportion of correct responses (Pcorr, related to the area under the ROC curve) as a summary metric of observer performance. The radiation dose levels for detection of 99% of nodules in each task were as follows: Task 1 (1 mGy); Task 2 (5 mGy); and Task 3 (7 mGy). The corresponding interobserver confidence limits were 1, 5, and 10 mGy for Tasks 1, 2, and 3, respectively. There was a fivefold increase in the radiation dose required for detection of lower-density nodules (Tasks 1 to 2). Absence of prior knowledge of the nodule size and density (Task 3) corresponds to a significant increase in the minimum required radiation dose. Significant image

  19. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Raupach, Rainer; Flohr, Thomas [Siemens Medical Solutions, Forchheim (Germany); Sommer, Torsten [University of Bonn, Department of Radiology, Bonn (Germany)

    2006-04-15

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% {+-}10%) and more realistic lumen attenuation (222 HU {+-}66 HU) at the expense of increased noise (15.3 HU {+-}3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  20. The diagnostic accuracy of multidetector row CT for evaluating the axillary lymph nodes in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Doo Kyung; Kim, Jun Man; Yim, Hyun Ee [Ajou University, College of Medicine, Suwon (Korea, Republic of)

    2007-08-15

    We investigated the CT (computed tomography) findings of metastatic lymph nodes (LNs), and we analyzed the diagnostic performance of multidetector row CT (MDCT) for detecting axillary LN metastases in patients with breast cancer. We investigated 59 patients who preoperatively underwent chest MDCT, and they underwent sentinel LN biopsy ro whole axillary LN dissection. We analyzed the morphologic features, the degree of enhancement and the delayed enhancement pattern. We classified the patients into the non-metastatic LN group and the metastatic LN group, and we calculated the diagnostic performance of MDCT for detecting metastatic LNs. When both the morphologic and quantitative criteria were consistent, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 58.1%, 100%, 100% and 68.3%, respectively, and MDCT accurately detected metastatic LNs in 2 patients that were false negative on sentinel LN biopsy. When the morphologic and quantitative criteria were consistent, the sensitivity, specificity, PPV and NPV were 87.1%, 53.6%, 67.5% and 78.9%, respectively. However, MDCT could not detect metastatic LNs, including two micrometastases (a total of 8 micrometastases) that were in each of four patients. MDCT can be used to perform the morphology and quantitative analysis of axillary LNs, and this modality has excellent specificity and a PPV for detecting metastatic LNs when the both of the diagnostic criteria are consistent.

  1. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  2. Accuracy of hydro-multidetector row CT in the local T staging of oesophageal cancer compared to postoperative histopathological results

    International Nuclear Information System (INIS)

    To evaluate the accuracy of multidetector computed tomography with water filling (Hydro-MDCT) in the T-staging of patients with oesophageal cancer. There were 131 consecutive patients who were preoperatively and prospectively examined in the prone position on arterial phase contrast-enhanced MDCT, after ingestion of 1,000-1,500 ml tap water and effervescent granules. Two readers staged the local tumour growth (T-staging) independently. They assessed tumour location, size, presence of stenosis, and morphology of the outer border of the oesophageal wall and perioesophageal fat planes on CT. CT findings were compared with histopathological results from resected specimens. Data were analyzed using the SPSS statistical package. Both readers obtained a high sensitivity of 95% and a high positive predictive value of 96%. Accurate local staging was achieved in 76.3% and 68.7% for readers 1 and 2, respectively. Inter-reader agreement was excellent (weighted κ value of 0.93 and un-weighted κ of 0.89). Using the hydro-technique and applying specific assessment criteria, MDCT appears to be an accurate, non-invasive diagnostic tool for local tumour staging of oesophageal cancer. (orig.)

  3. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    International Nuclear Information System (INIS)

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size ≤20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  4. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    Energy Technology Data Exchange (ETDEWEB)

    Symersky, Petr [Onze Lieve Vrouwe Gasthuis, Department of Cardiothoracic Surgery, Oosterpark 9, P.O box 95500, Amsterdam (Netherlands); Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Westers, Paul [Julius Center for Health Sciences and Primary Care, Department of Biostatistics, Utrecht (Netherlands); Mol, Bas A.J.M. de [Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); University of Technology Eindhoven, Department of Biomedical Engineering, Eindhoven (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Center, Department of Radiology, Nijmegen (Netherlands)

    2011-10-15

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall tilting disc (MH), and Carbomedics (CM), St Jude (SJM), and ON-X bileaflet valves underwent CT in an in-vitro model using retrospective gating with a 64 detector CT system in stationary and pulsatile conditions. Artifacts and radiopaque component volumes were quantified with thresholds based on surrounding structures and valvular components. Hypodense artifacts volumes (mm{sup 3}) were 1,029 {+-} 147, 535 {+-} 53, 371 {+-} 16, and 366 {+-} 18 for the SJM, MH, CM and ON-X valves (p < 0.001 except for the latter two valves p = 0.43). Hyperdense artifact volumes were 3,546 {+-} 141, 2,387 {+-} 103, 2,003 {+-} 102, and 3,033 {+-} 31 for the SJM, MH, CM and ON-X valve, respectively (all differences p < 0.001). Leaflet motion affected hypodense (F = 41.5, p < 0.001) and hyperdense artifacts (F = 53.7, p < 0.001). Closed and moving leaflets were associated with the least and the most artifacts respectively (p < 0.001, both artifact types). Both valve design and leaflet motion affect PHV-induced artifacts. Best imaging results may be expected for the CM valve during phases in which the leaflets are closed. (orig.)

  5. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    Energy Technology Data Exchange (ETDEWEB)

    Addley, H.C., E-mail: helenclareaddley@hotmail.co.u [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Griffin, N.; Shaw, A.S.; Mannelli, L. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Parker, R.A. [Department of Medical Statistics, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Aitken, S.; Wood, H. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Davies, S. [Department of Histopathology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Alexander, G.J. [Department of Hepatology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Lomas, D.J. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-04-15

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size {<=}20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  6. Role of Multidetector CT in Evaluation of Acute Chest Pain: Non-Cardiac Vascular and Pulmonary Causes

    Directory of Open Access Journals (Sweden)

    Rania S Sayed *, Hisham M Mansour **, Mohammad H Khaleel ***, Sherif H Abo Gamra ** and Merhan A Nasr

    2013-04-01

    Full Text Available Background: Triage of patients with acute chest pain is one of the most important issues currently facing physicians in the emergency department. Acute chest pain may be a symptom of a number of serious conditions and is generally considered a medical emergency. The causes of acute chest pain range from non-serious to life threatening. A rapid, accurate and cost-effective approach for the evaluation of emergency department patients with chest pain is needed. Aim of the work: This work aims to emphasize the role of multidetector CT in assessment of non-cardiac vascular and pulmonary causes of acute chest pain.Method: The studied group included 89 patients (59 men and 30 women presented by acute chest pain. All patients were subjected to MDCT and/or MDCT angiography using a Toshiba 64 detectors CT scanner. Results: The high spatial resolution and relatively non-invasive nature make MSCT angiography a strong and serious competitor to established vascular imaging techniques. Having the additional ability to simultaneously acquire information on other organs, which enables the early diagnosis of complications. Conclusion: Continued technical improvements in acquisition speed and spatial resolution of computed tomography images, and development of more efficient image reconstruction algorithms which reduce patient exposure to radiation and contrast result in increased popularity of MDCT.

  7. Cardiac Multi-detector CT Segmentation Based on Multiscale Directional Edge Detector and 3D Level Set.

    Science.gov (United States)

    Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna

    2016-05-01

    Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images. PMID:26319010

  8. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    International Nuclear Information System (INIS)

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD

  9. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    International Nuclear Information System (INIS)

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  10. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Energy Technology Data Exchange (ETDEWEB)

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  11. Volumetric Measurements of Lung Nodules with Multi-Detector Row CT: Effect of Changes in Lung Volume

    International Nuclear Information System (INIS)

    To evaluate how changes in lung volume affect volumetric measurements of lung nodules using a multi-detector row CT. Ten subjects with asthma or chronic bronchitis who had one or more lung nodules were included. For each subject, two sets of CT images were obtained at inspiration and at expiration. A total of 33 nodules (23 nodules ≥3 mm) were identified and their volume measured using a semiautomatic volume measurement program. Differences between nodule volume on inspiration and expiration were compared using the paired t-test. Percent differences, between on inspiration and expiration, in nodule attenuation, total lung volume, whole lung attenuation, and regional lung attenuation, were computed and compared with percent difference in nodule volume determined by linear correlation analysis. The difference in nodule volume observed between inspiration and expiration was significant (p < 0.01); the mean percent difference in lung nodule volume was 23.1% for all nodules and for nodules ≥3 mm. The volume of nodules was measured to be larger on expiration CT than on inspiration CT (28 out of 33 nodules; 19 out of 23 nodules ≥3 mm). A statistically significant correlation was found between the percent difference of lung nodule volume and lung volume or regional lung attenuation (p < 0.05) for nodules ≥3 mm. Volumetric measurements of pulmonary nodules were significantly affected by changes in lung volume. The variability in this respiration-related measurement should be considered to determine whether growth has occurred in a lung nodule

  12. Monte Carlo simulations with MENATE program in order to determine the characteristics of neutron multidetector

    International Nuclear Information System (INIS)

    The neutron multidetector consists of 81 detectors, made of 4x4x12 cmc BC-400 crystals mounted on XP2972 phototubes. This detector placed in the forward direction at 138 cm from the target, was used to detect the correlated neutrons in the fusion of Li11 halo nuclei with Si targets. To verify the criterion for selecting the true coincidences against cross-talk ( a spurious effect in which the same neutron is registered by two or more detectors) and to establish the optimal distance between adjacent detectors, the program MENATE ( written by P.Desesquelles, IPN - Orsay) was used to generate Monte Carlo neutrons and their interactions in multidetector. The results were analysed with PAW (from CERN Library). (authors)

  13. The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note

    International Nuclear Information System (INIS)

    Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward

  14. Blind-ending branch of a bifid ureter: multidetector CT imaging findings

    Science.gov (United States)

    Chang, E; Santillan, C; O'Boyle, M K

    2011-01-01

    A bifid ureter with a blind-ending branch is a rare congenital anomaly. Although typically found incidentally, this anomaly can be symptomatic and radiologists should be aware of this important variant. To our knowledge, there has been no previous report of this anomaly as seen on multidetector CT urography. We present a patient with haematuria and review the clinical significance, radiological findings and embryological aetiology of this anomaly. PMID:21257834

  15. Nuclear structure at high spin using multidetector gamma array and ancillary detectors

    Indian Academy of Sciences (India)

    S Muralithar

    2014-04-01

    A multidetector gamma array (GDA), for studying nuclear structure was built with ancillary devices namely gamma multiplicity filter and charged particle detector array. This facility was designed for in-beam gamma spectroscopy measurements in fusion evaporation reactions at Inter-University Accelerator Centre, New Delhi. Description of the facility and in-beam performance with two experimental studies done are presented. This array was used in a number of nuclear spectroscopic and reaction investigations.

  16. Multi-detector CT/CT angiogram assessment of acute pancreatic graft dysfunction

    International Nuclear Information System (INIS)

    Simultaneous pancreatic-kidney transplantation is the definitive treatment for patients with type 1 diabetes mellitus and renal failure. Pancreatic graft failure is an important postoperative complication and most commonly occurs as a result of pancreatitis, graft thrombosis or rejection. Distinguishing between these causes is necessary to determine timely, appropriate management and thereby potentially minimising graft loss. Multi-detector CT imaging may be used to identify the cause of pancreatic graft dysfunction when renal function is not markedly impaired.

  17. Diagnosis of arterioportal shunts in cases of hepatocellular carcinoma using multidetector CT: Impact on clinical management

    OpenAIRE

    Ahmed Mostafa Mohamed; Mohamed El Gharib A. Elmaaty; Ayman Mohamed Ibrahim; Waleed Hamed; Amr Hafez El Fouly

    2014-01-01

    Purpose: To study the ability of multidetector CT (MDCT) to diagnose arterioportal shunts (APS) associated with hepatocellular carcinoma (HCC) and its impact on further management of the patient. Patients and methods: 252 Patients with HCC were examined by triphasic MDCT scanning. Images were analyzed for the presence, locations, types and degrees of APS, being with or without thrombosis. Digital subtraction angiographies (DSA) were performed for 22 patients as a part of further therapeuti...

  18. Study of statistical properties of hybrid statistic in coherent multi-detector CBC Search

    CERN Document Server

    Haris, K

    2015-01-01

    In this article, we revisit the problem of coherent multi-detector search of gravitational wave from compact binary coalescence with Neutron stars and Black Holes using advanced interferometers like LIGO-Virgo. Based on the loss of optimal multi-detector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio(MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives low false alarms compared to the multi-detector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We have demonstrated that for a LIGO-Virgo network and binary inclination, \\epsilon 110 deg., the hybrid statistic captures more than 98% of network optimum matched filter SNR with low false alarm rate. The...

  19. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  20. Imaging of Herniated Discs of the Cervical Spine: Inter-Modality Differences between 64-Slice Multidetector CT and 1.5-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Ji Sook; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Han, Jong Kyu [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Kim, Hyun Joo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2015-08-15

    To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI.

  1. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  2. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  3. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  4. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  5. Upper abdominal gadoxetic acid-enhanced and diffusion-weighted MRI for the detection of gastric cancer: Comparison with two-dimensional multidetector row CT

    International Nuclear Information System (INIS)

    Aim: To evaluate the diagnostic performance of abdominal magnetic resonance imaging (MRI) for the detection of gastric cancer in comparison with that of two-dimensional (2D) multidetector row computed tomography (CT). Materials and methods: The study included 189 patients with 170 surgically confirmed gastric cancers and 19 patients without gastric cancer, all of whom underwent gadoxetic acid-enhanced MRI with diffusion-weighted (DW) imaging, and multidetector contrast-enhanced abdominal CT imaging. Two observers independently analysed three sets of images (CT set, conventional MRI set, and combined conventional and DW MRI set). A five-point scale for likelihood of gastric cancer was used. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were evaluated. Quantitative [apparent diffusion coefficient (ADC) analyses with Mann–Whitney U-test were conducted for gastric cancers and the nearby normal gastric wall. Results: The diagnostic accuracy and sensitivity for detection of gastric cancer were significantly higher on combined conventional and DW MRI set (77.8–78.3%; 75.3–75.9%) than the CT imaging set (67.7–71.4%; 64.1–68.2%) or the conventional MRI set (72–73%; 68.8–70%; p < 0.01). In particular, for gastric cancers with pT2 and pT3, the combined conventional and DW MRI set (91.6–92.6%) yielded significantly higher sensitivity for detection of gastric cancer than did the CT imaging set (76.8–81.1%) by both observers (p < 0.01). The mean ADC of gastric cancer lesions (1 ± 0.23 × 10−3mm2/s) differed significantly from that of normal gastric wall (1.77 ± 0.25 × 10−3 mm2/s; p < 0.01). Conclusion: Abdominal MRI with DW imaging was more sensitive for the detection of gastric cancer than 2D-multidetector row CT or conventional MRI alone. - Highlights: • The sensitivity for detection of gastric cancer is high on abdominal MR imaging. • DW imaging is helpful for detection of

  6. COMPUTING

    CERN Document Server

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  7. Computer

    CERN Document Server

    Atkinson, Paul

    2011-01-01

    The pixelated rectangle we spend most of our day staring at in silence is not the television as many long feared, but the computer-the ubiquitous portal of work and personal lives. At this point, the computer is almost so common we don't notice it in our view. It's difficult to envision that not that long ago it was a gigantic, room-sized structure only to be accessed by a few inspiring as much awe and respect as fear and mystery. Now that the machine has decreased in size and increased in popular use, the computer has become a prosaic appliance, little-more noted than a toaster. These dramati

  8. Reducing radiation dose in 64-row spiral CT coronary angiography: study based on individualized scan dosage protocol

    International Nuclear Information System (INIS)

    Objective: To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol. Methods: Two hundred patients (group A) underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI. The mA was set as 150-300 mA (BMI < 18.5 kg/m2), 300-500 mA (18.5 kg/m2 ≤ BMI < 25.0 kg/m2), and 500-800 mA (BMI ≥ 25.0 kg/m2). When all examinations were finished, a linear regression was employed to analyze the correlation between mA and BMI, body surface (Suf), image noise (SD) respectively. The results of the analysis were used to formulate a regression equation, which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need. Another 200 patients (group B) enrolled for the individualized scan were scanned under new protocol that previous study established. The tube voltage was 100 and 120 kV. The tube current was variable according to the data in the table list. One-way ANOVA and Kruskal-wallis H test were used for statistics. Results: Regression equation between mA and BMI, Suf, SD was: mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039. The SD (group A: 32.08 ± 5.80, group B: 28.60±4.47), dose index volume (CTDIvol) [group A: (41.97 ± 11.37) mGy, group B: (33.18±10.07) mGy], effective dose(ED) [group A: (10.91 ±3.07) mSy, group B: (8.83 ±2.72)mSv] had significant differences between the two groups (F=43.45, 63.71, 49.07 respectively, P<0.01 for all). The SD and ED results obtained in group B were better than those in group A. Conclusion: Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only, which means good image quality and lower radiation dosage in coronary CTA examination. (authors)

  9. Detection of hypervascular hepatocellular carcinoma: Comparison of multi-detector CT with digital subtraction angiography and Lipiodol CT

    Institute of Scientific and Technical Information of China (English)

    Xiao-Hua Zheng; Yong-Song Guan; Xiang-Ping Zhou; Juan Huang; Long Sun; Xiao Li; Yuan Liu

    2005-01-01

    AIM: The purpose of this study was to compare the diagnostic accuracy of biphasic multi-detector row helical computed tomography (MDCT), digital subtraction angiography (DSA)and Lipiodol computed tomography (CT) in detection of hypervascular hepatocellular carcinoma (HCC).METHODS: Twenty-eight patients with nodular HCC underwent biphasic MDCT examination: hepatic arterial phase (HAP) 25 s and portal venous phase (PVP) 70 s after injection of the contrast medium (1.5 mL/kg). They also underwent hepatic angiography and intra-arterial infusion of iodized oil. Lipiodol CT was performed 3-4 wk after infusion. MDCT images were compared with DSA and Lipiodol CT images for detection of hepatic nodules.RESULTS: The three imaging techniques had the same sensitivity in detecting nodules >20 mm in diameter. There was no significant difference in the sensitivity among HAP-MDCT, Lipiodol CT and DSA for nodules of 10-20 mm in diameter. For the nodules <10 mm in diameter, HAP-MDCT identified 47, Lipiodol CT detected 27 (X2= 11.3, P= 0.005<0.01, HAP-MDCT vs Lipiodol CT) and DSA detected 16(X2= 9.09, P= 0.005<0.01 vs Lipiodol CT and X2= 29.03,P = 0.005<0.01 vs HAP-MDCT). However, six nodules <10 mm in diameter were detected only by Lipiodol CT.CONCLUSION: MDCT and Lipiodol CT are two complementary modalities. At present, MDCT does not obviate the need for DSA and subsequent Lipiodol CT as a preoperative examination for HCC.

  10. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  11. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  12. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  13. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  14. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  15. COMPUTING

    CERN Document Server

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  16. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  17. COMPUTING

    CERN Document Server

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  18. COMPUTING

    CERN Document Server

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  19. Prognostic value of multi-detector computed tomography in asymptomatic aortic valve stenosis

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig;

    2016-01-01

    was defined as indication for aortic valve replacement (AVR) determined by the treating physician or sudden cardiac death. RESULTS: The mean age was 72 (8) years, 27% were women, mean AVA by TTE was 1.01 (0.30) cm(2). Median follow up time was 27 (IQR 19-44) months. Forty seven patients (41%) developed...... indication for AVR. No patients suffered a sudden cardiac death. AVA and aortic valve calcification were significant univariable predictors of AVR when measured by both TTE and MDCT, whereas left ventricular mass was only significant measured by MDCT. Significant coronary artery disease by MDCT tended...... to predict future indication for AVR, but this did not reach statistical significance (HR: 1.79 (95% CI 0.96-3.44), p=0.08). CONCLUSION: MDCT derived AVA can be of use as an alternative to TTE derived AVA in patients with asymptomatic AS to predict future clinical indication for AVR....

  20. Multi-detector computed tomography (MDCT findings of chemotherapy induced hepatic chan

    Directory of Open Access Journals (Sweden)

    Sieza Samir Abd-Allah

    2016-09-01

    Results: Forty patients (32 females and 8 males had hepatic changes due to effect of chemotherapy. The most common CT finding was fatty liver. Hepatic fatty changes were detected in 36/40 patients. These fatty changes were diffuse, focal fatty and diffuse with fatty spare area. Four patients had capsular retraction: 1 patient with HD and 3 patients with metastatic cancer breast. Veno-occlusive disease and biliary sclerosis were not detected.

  1. Cardiac Multidetector Computed Tomography: Basic Physics of Image Acquisition and Clinical Applications

    OpenAIRE

    Bardo, Dianna M.E; Brown, Paul

    2008-01-01

    Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics. This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 – 320 detectors, flat panels, single and dual source configurations, step and shoot prospective a...

  2. Retrospective Evaluation of Detection of Minimal Preparedness Multidetector Computed Tomography with Colorectal Neoplasms

    OpenAIRE

    Üngür, Naci; Bozdağ, Zübeyir; Yılmaz, Edip Erdal; Hatttoğlu, Salih; Teke, Memik; Uçmak, Feyzullah; Göya, Cemil

    2015-01-01

     Purpose: The aim of this study is to retrospectively assess the contrubition of the minimal preparation CT to the diagnosis of colorectal cancer in the patients who were refered to department of gatroenterology with colorectal cancer prediagnosis and have consequent colonoscopically visible mass and histopathological proof.Materials and methods: 100 consecutive cases referred from department of gastroenterology between september 2008 and december 2012 with confirmed colonoscopical mass diagn...

  3. Diagnostic performance of multidetector computed tomography in the evaluation of esoph

    Directory of Open Access Journals (Sweden)

    Tarek ELKammash

    2016-03-01

    Conclusion: MDCT is a fast, well tolerable, non-invasive procedure and accepted from most of the examined patients for evaluation and grading of EV, detection of other portosystemic collaterals and hepatobiliary pathologies.

  4. Diagnostic Potential of Multidetector Computed Tomography for Characterizing Small Renal Masses

    Directory of Open Access Journals (Sweden)

    Maria Elisabetta Mancini

    2015-01-01

    Full Text Available Objectives. To assess the potential of CT for characterizing small renal tumors. Methods. 76 patients with <4 cm renal tumors underwent CT examination. The following parameters were assessed: presence of calcifications, densitometry on unenhanced and enhanced scans, washout percentage, urinary tract infiltration, star-shaped scar, and paradoxical effect. Results. Calcifications were found in 7/56 (12.5% carcinomas. Clear cell carcinomas were as follows: mean density 183.5 HU (arterial phase, 136 HU (portal phase, and 94 HU (delayed phase, washout 34.3%; chromophobe carcinomas were as follows: mean density 135 HU (arterial phase, 161 HU (portal phase, and 148 HU (delayed phase, washout 28%; papillary carcinomas were as follows: mean density 50.3 HU (arterial phase, 60 HU (portal phase, and 58.1 HU (delayed phase, washout 2.7%. In 2/56 (3.6% cases urinary tract infiltration was found. Oncocytomas were as follows: mean density 126.5 HU (arterial phase, 147.5 HU (portal phase, and 115.5 HU (delayed phase, washout 28.6%. On unenhanced scans, angiomyolipomas were as follows: density values <30 HU in 12/12 (100% of cases and on enhanced scans: mean density 78 HU (arterial phase, 128 HU (portal phase, and 80 HU (delayed phase, washout 50%. Conclusions. Intralesional calcifications and urinary tract infiltration are suggestive for malignancy, with the evidence of adipose tissue for angiomyolipomas and a modest increase in density with a reduced washout for papillary carcinomas. The intralesional density on enhanced scans, peak enhancement, and washout do not seem significant for differentiating clear cell, chromophobe carcinomas, angiomyolipomas, and oncocytomas.

  5. Pancreatic and peri-pancreatic lesions mimic pancreatic islet cell tumor in multidetector computed tomography

    Institute of Scientific and Technical Information of China (English)

    XUE Hua-dan; LIU Wei; XIAO Yu; SUN Hao; WANG Xuan; LEI Jing; JIN Zheng-yu

    2011-01-01

    Objective This pictorial review aimed to summarize the most possible differential diagnosis of pancreatic islet cell tumor (PICT).Data sources Data used in this review were mainly from Medline and Pubmed in English. And all clinical images in this review were from Department of Radiology, Peking Union Medical College Hospital, Beijing, China.Study selection Cases of pancreatic cystadenoma, solid pseudo-papillary tumor of the pancreas, pancreatic metastasis, pancreatic adenocarcinoma, para-pancreatic neuroendocrine tumors, Castleman disease, gastrointestinal stromal tumor, splenic artery aneurysm and accessory spleen were selected in this pictorial review for differential diagnosis of PICT.Results Careful analysis of imaging features and correlation with the clinical manifestations may allow a more specific diagnosis. It is also important that the radiologist is familiar with the anatomic variants and disease entities which mimic pancreatic islet cell tumor in order to avoid an improper treatment protocol.Conclusions Many congenital anatomic variants or other pancreatic and peri-pancreatic diseases may mimic MDCT appearance of pancreatic islet cell tumor. Radiological, clinical and pathological characteristics should be considered for the final diagnosis.

  6. Usefulness of multidetector-row CT (MD-CT) for assessment of coronary artery stenosis

    International Nuclear Information System (INIS)

    Coronary arteries stenosis were evaluated in 49 cases by volume rendering (VR) and partial maximum intensity projection (partial MIP) using multidetector-row CT (MD-CT). Left main trunk (LMT) and left anterior descending artery (LAD) were less affected by cardiac pulsation artifact and presented good images. Right coronary artery (RCA) was affected by cardiac pulsation artifact and image quality was inferior as compared to left coronary artery (LCA). It is suggested that MD-CT is useful for assessment of coronary artery stenosis, especially LCA. (author)

  7. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware

    Energy Technology Data Exchange (ETDEWEB)

    Vande Berg, Bruno [Department of Radiology, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200 Brussels (Belgium)]. E-mail: vandeberg@rdgn.ucl.ac.be; Malghem, Jacques [Department of Radiology, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200 Brussels (Belgium); Maldague, Baudouin [Department of Radiology, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200 Brussels (Belgium); Lecouvet, Frederic [Department of Radiology, Cliniques Universitaires Saint-Luc, 10 Avenue Hippocrate, 1200 Brussels (Belgium)

    2006-12-15

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.

  8. Impact parameter and source selected correlation functions with a 4π multidetector

    International Nuclear Information System (INIS)

    For the first time in the domain of (light charged) particle interferometry in nuclear physics, a complete study of proton an deuteron correlation functions is presented with both impact parameter and emission source selections. The correlations were determined for the system 129Xe + natSn at 45 and 50 AMeV using the 4π multidetector INDRA at GANIL as an event selector as well as a particle correlator. Very short emission times are found for all the selections indicating possible contributions from a fast and preequilibrium process. (author)

  9. Detectability of the appendix with multidetector-row CT scanning and multiplanar reconstruction

    International Nuclear Information System (INIS)

    Twenty-six consecutive patients with the clinical diagnosis of appendicitis underwent multidetector-row CT (MD-CT) in order to detect entire longitudinal configuration of the appendix. While axial CT failed to detect the appendix in 7 patients, multiplanar reconstruction (MPR) demonstrated a longitudinal tubular structure continuous from the cecal caput in 25 patients (96.2%), including 7 patients whose post-surgical pathology were available. It is summarized that scanning and MPR images are advantageous to finding inflammatory processes in the appendix when the diagnosis of appendicitis remains ambiguous even with US. (author)

  10. Double Chooz: optimizing the sensitivity to {theta}{sub 13} with a multi-detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Novella, P. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain)

    2012-08-15

    The best upper limit to the neutrino mixing angle {theta}{sub 13} is set by the CHOOZ experiment. The eventual measurement of {theta}{sub 13} in reactor neutrino experiments relies on a reduction of the CHOOZ systematics of about 1 order of magnitude, along with a major increase of the luminosity. Provided that enough statistics are achieved, fighting the systematics becomes the key towards {theta}{sub 13}. The Double Chooz experiment engages this fight with a multi-detector set up.

  11. Multi-scale analysis of lung computed tomography images

    OpenAIRE

    Gori, I.; Bagagli, F.; Fantacci, M. E.; Martinez, A. Preite; Retico, A.; De Mitri, I.; Donadio, S.; Fulcheri, C.; Gargano, G; Magro, R.; Santoro, M; Stumbo, S

    2009-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on...

  12. Importance of multidetector CT imaging in multiple trauma; Stellenwert der Multidetektor-CT bei Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U. [HELIOS Kliniken Muenchen West, HELIOS Klinik Muenchen Perlach, Institut fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Geyer, L.L.; Reiser, M.; Wirth, S. [Klinikum der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Koerner, M. [Radiologie Muehleninsel, Landshut (Germany)

    2014-09-15

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [German] Die Diagnostik komplexer Mehrfachverletzungen ist eine Herausforderung fuer die moderne radiologische Notfalldiagnostik. Eine umfassend angelegte, fruehe und praezise radiologische Diagnostik ist entscheidend fuer eine prioritaetenorientierte und

  13. COMPUTING

    CERN Multimedia

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  14. COMPUTING

    CERN Document Server

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  15. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  16. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  17. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  18. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  19. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  20. Optimisation of vascular input and output functions in CT-perfusion imaging using 256(or more)-slice multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Niesten, Joris M.; Schaaf, Irene C. van der; Riordan, Alan J.; Jong, Hugo W.A.M. de; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2013-05-15

    To evaluate the accuracy and reproducibility of CT-perfusion (CTP) by finding the optimal artery for the arterial input function (AIF) and re-evaluating the necessity of the venous output function (VOF). Forty-four acute ischaemic stroke patients who underwent non-enhanced CT, CTP and CT-angiography using 256-slice multidetector computed tomography (MDCT) were evaluated. The anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery were selected as the AIF. Subsequently the resulting area under the time-enhancement curve of the AIF (AUC{sub AIF}) and quantitative perfusion measurements were analysed by repeated measures ANOVA and subsequently the paired t test. To evaluate reproducibility we examined if the VOF could be deleted by comparing the perfusion measurements using versus not using the VOF (paired t test). The AUC{sub AIF} and perfusion measurements resulting from the different AIFs showed significant group differences (all P < 0.0001). The ICA had the largest AUC{sub AIF} and resulted in the highest mean transient time (MTT) and lowest cerebral blood flow (CBF), whereas the basilar artery showed the lowest cerebral blood volume (CBV). Not using the VOF showed significantly higher CBV and CBF in 66 % of patients on the ipsilateral (P < 0.0001 and P = 0.007, respectively) and contralateral hemisphere (P < 0.0001 and P = 0.019, respectively). Selecting the ICA as the AIF and continuing the use of the VOF would improve the accuracy of CTP. (orig.)

  1. Regenerative nodules in patients with chronic Budd-Chiari syndrome: A longitudinal study using multiphase contrast-enhanced multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Flor, Nicola [Unita Operativa di Radiologia Diagnostica Interventistica, University of Milan School of Medicine, Ospedale San Paolo, Milan (Italy)], E-mail: flornic@hotmail.com; Zuin, Massimo [Unita Operativa di Epatologia e Gastroenterologia Medica, University of Milan School of Medicine, Ospedale San Paolo, Via A. di Rudini 8, 20142 Milan (Italy); Brovelli, Francesca [Department of Radiology, Centro Diagnostico Italiano, Milan (Italy); Maggioni, Marco [Servizio di Anatomia Patologica, Ospedale San Paolo, Milan (Italy); Tentori, Augusta [Servizio di Radiologia, Ospedale di Voghera (Italy); Sardanelli, Francesco [Radiology, IRCCS Policlinico San Donato, University of Milan School of Medicine, Milan (Italy); Cornalba, Gian Paolo [Unita Operativa di Radiologia Diagnostica Interventistica, University of Milan School of Medicine, Ospedale San Paolo, Milan (Italy)

    2010-03-15

    Objective: Our aim was to evaluate the serial evolution of regenerative nodules in patients with Budd-Chiari syndrome (BCS) treated with portal-systemic shunts, using multiphasic multidetector computed tomography (MDCT). Materials and methods: Five patients each underwent three MDCT exams over an extended period ranging from 36 to 42 months. Two radiologists in consensus retrospectively reviewed each exam for each patient. Individual nodules were grouped according to size (size I: nodules with diameter {<=}15 mm; size II: >15 mm but <30 mm; size III: {>=}30 mm), pattern of enhancement (A: homogeneously hypervascular or B: with central scar), and segmental location. Four nodules classified as size II, which increased in size over time, were needle-biopsied. Results: We detected 61 nodules at the first exam, 66 nodules at the second exam (7 nodules disappeared and 12 new nodules), and 85 nodules at the third exam (8 disappeared and 27 new) for a total of 212 findings. Nodules were mostly found in the right hepatic lobe. Fourteen of the 15 nodules that disappeared over time were size I and enhancement pattern A. At unenhanced MDCT, 204 (96%) of the 212 findings were isodense. Overall, 100 nodules, including the 61 initially detected, were considered newly diagnosed; of these 84 (84%) were size I and pattern A. Of 57 nodules considered size I and pattern A at the first or second exam, 24 (42%) changed to pattern B at the third exam and either size II (n = 18) or III (n = 6). The four biopsied nodules were each confirmed as benign regenerative nodule. No patient developed HCC at 5-year follow-up period. Conclusion: Hepatic nodules in BCS patients not only increase in number over time but may also increase in size and develop a central scar.

  2. Usefulness of multi-detector CT in boyd-Griffin type 2 intertrochanteric fractures with clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Han, Suk-Ku; Choi, Nam-Yong [College of Medicine, Catholic University of Korea, Department of Orthopaedic Surgery, St. Paul' s Hospital, Seoul (Korea); Lee, Bae-Young; Kim, Yong-Sik [College of Medicine, Catholic University of Korea, Department of Radiology, St. Paul' s Hospital, Seoul (Korea)

    2010-06-15

    To investigate the usefulness of multi-detector computed tomography (MDCT) in three-part intertrochanteric fractures of proximal femur. Twenty-six patients with Boyd-Griffin type 2 intertrochanteric fractures with MDCT (group 1) and 36 patients of the same type fracture without MDCT (group 2) were compared. Lesser trochanter (LT)/greater trochanter (GT) volume ratio above 0.5 or the volumetric proportion of GT in total volume of proximal femur below 25% was considered an unstable fracture. The fractures were fixed with dynamic compression hip screws (DCS). Additional greater trochanter stabilizing (GTS) plate or bone cement augmentation of the femoral head was performed in unstable fractures. Clinical outcome between the two groups by fixation failure and radiological results was compared. The volume ratio of the LT/GT was 0.33 (range, 0.13-0.73). The volume of the LT was inversely correlated with that of the GT (p < 0.001). The volume of the GT was significantly correlated with the LT/GT ratio or the head and neck (HN)/GT ratio (p < 0.001). Seven cases were regarded as unstable fractures in group 1. Fixation failures happened in one case in group 1 and five cases in group 2. There was significantly lower failure rate in group 1 than group 2 (p=0.03). Neck-shaft angle at last follow-up was 134.8 {+-} 5.3 in group 1 and 131.3 {+-} 5.1 in group 2 (p = 0.01). The sliding length of lag screws were 5.6 {+-} 2.9 mm in group 1 and 8.3 {+-} 3.2 in group 2 (p=0.03). Preoperative use of MDCT provides useful information about the fracture pattern and the geometry of the proximal femur in unstable intertrochanteric fractures and helps surgical planning. The ratio of the LT to the GT is inversely correlated with fracture stability. (orig.)

  3. Regenerative nodules in patients with chronic Budd-Chiari syndrome: A longitudinal study using multiphase contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Objective: Our aim was to evaluate the serial evolution of regenerative nodules in patients with Budd-Chiari syndrome (BCS) treated with portal-systemic shunts, using multiphasic multidetector computed tomography (MDCT). Materials and methods: Five patients each underwent three MDCT exams over an extended period ranging from 36 to 42 months. Two radiologists in consensus retrospectively reviewed each exam for each patient. Individual nodules were grouped according to size (size I: nodules with diameter ≤15 mm; size II: >15 mm but <30 mm; size III: ≥30 mm), pattern of enhancement (A: homogeneously hypervascular or B: with central scar), and segmental location. Four nodules classified as size II, which increased in size over time, were needle-biopsied. Results: We detected 61 nodules at the first exam, 66 nodules at the second exam (7 nodules disappeared and 12 new nodules), and 85 nodules at the third exam (8 disappeared and 27 new) for a total of 212 findings. Nodules were mostly found in the right hepatic lobe. Fourteen of the 15 nodules that disappeared over time were size I and enhancement pattern A. At unenhanced MDCT, 204 (96%) of the 212 findings were isodense. Overall, 100 nodules, including the 61 initially detected, were considered newly diagnosed; of these 84 (84%) were size I and pattern A. Of 57 nodules considered size I and pattern A at the first or second exam, 24 (42%) changed to pattern B at the third exam and either size II (n = 18) or III (n = 6). The four biopsied nodules were each confirmed as benign regenerative nodule. No patient developed HCC at 5-year follow-up period. Conclusion: Hepatic nodules in BCS patients not only increase in number over time but may also increase in size and develop a central scar.

  4. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  5. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  6. Novel wearable and wireless ring-type pulse oximeter with multi-detectors.

    Science.gov (United States)

    Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh

    2014-01-01

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  7. Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors

    Directory of Open Access Journals (Sweden)

    Cheng-Yang Huang

    2014-09-01

    Full Text Available The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2. Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  8. Comparative evaluation of multidetector CT and MR imaging in the differentiation of adnexal masses

    International Nuclear Information System (INIS)

    The purpose was to compare the accuracy of multidetector CT (MDCT) on a 16-row CT scanner and magnetic resonance (MR) imaging in the characterization of ovarian masses. Preoperative CT examination of the abdomen and MR imaging of the pelvis was performed in 67 women, with clinically or sonographically detected adnexal masses. The CT examinations were performed on a 16-row CT scanner, and the protocol included scanning of the abdomen during the portal phase, using a detector collimation of 16 x 0.75 mm and a pitch of 1.2. We used a 1.5-T magnet unit to perform T1, T2 and fat-suppressed T1-weighted sequences, before and after intravenous administration of gadolinium chelate compounds. The accuracy of multidetector CT and MR imaging in the differentiation between benign and malignant ovarian masses was evaluated, using histopathologic results as the standard of reference. The sensitivity, specificity and accuracy of MDCT in the characterization of ovarian masses were 90.5%, 93.7% and 92.9%, respectively, and that of MR imaging 95.2%, 98.4% and 97.6%, respectively. Although MRI performed slightly better, this did not reach statistical significance. In conclusion, both MDCT on a 16-row CT scanner and MR imaging demonstrated satisfactory results in the characterization of ovarian masses. (orig.)

  9. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  10. Multidetector system for the search and investigation of high spin, high energy isomers produced in heavy ion induced nuclear reactions

    International Nuclear Information System (INIS)

    A multidetector system consisting of 14 NaI(Tl) detectors working in multifold coincidences with a Ge(Li) detector is presented. Its associated electronics and the hardware data acquisition system is described. Timing limitations of the method applied to the search for short half-life isomeric states are discussed. Some applications and results are briefly mentioned

  11. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bin [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Dong Hun; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Seo, Hye Sun [Dept. of Internal Medicine, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-02-15

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  12. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    International Nuclear Information System (INIS)

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  13. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    International Nuclear Information System (INIS)

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  14. Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Hoon; Jeong, Ho Gul; Park, Hyok; Park, Chang Seo; Kim, Kee Deog [Department of Oral and Maxillofacial Radiology, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Five partially edentulous dry human mandibles, with 1 X 1 mm gutta percha cones, placed in 5 mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1 mm, 200 mA, 120 kV 2) Multi-detector computed tomography: slice thickness 0.75 mm, 250 mA, 120 kV 3) Cone beam computed tomography: 15 mAs, 120 kV Axial images acquired from three computed tomographs were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant 2.0 (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta percha cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  15. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  16. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Science.gov (United States)

    Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.

  17. Estudio del oído con TC Multidetector de 64 canales 64 - Detector CT findings in the study of the ear

    Directory of Open Access Journals (Sweden)

    María Lourdes Mallo

    2010-12-01

    Full Text Available El oído es una estructura anatómica compleja. Su estudio y comprensión resultan un reto diario para el radiólogo, siendo la tomografía computada una herramienta esencial para su estudio. La tomografía computada convencional con cortes finos en planos axiales y coronales permite una buena visualización de las diferentes estructuras. Sin embargo, se necesitan tiempos prolongados para su realización y posicionamientos incómodos o intolerables para muchos pacientes. Además la visualización de algunas de sus estructuras es limitada. La tomografía axial computada multidetector de 64 canales a nuestro medio permite optimizar el estudio de la compleja y pequeña anatomía del oído. La realización de adquisiciones volumétricas con cortes de 0,5 mm, con reconstrucciones multiplanares en los tres planos básicos, en planos curvos y reconstrucciones tridimensionales, hacen posible la visualización detallada de las estructuras en escasos segundos y en condiciones cómodas para el paciente. Nuestro propósito en este artículo es demostrar la utilidad de las reconstrucciones, particularmente en planos oblicuos, para identificar y analizar los diferentes reparos anatómicos del oído y alcanzar la visualización óptima de la anatomía relevante del hueso temporal.The ear is a complex anatomic structure. Its study and understanding represent a constant challenge for the radiologist. As a consequence the computed tomography becomes an essential tool for its examination. Conventional tomographic examination with both axial and coronal reconstruction of the image allows a satisfactory visualization of the different structures. However, the study requires long periods of time for its acquisition and uncomfortable or intolerable positions for the patients. Moreover, the characterization of some structures of the ear becomes limited. Sixty-four slice multidetector computed tomography allows the optimal study of the small and complex ear anatomy

  18. Value of multidetector spiral CT in diagnosis of acute thoracolumbar spinal fracture and fracture-dislocation

    Institute of Scientific and Technical Information of China (English)

    龚静山; 徐坚民

    2004-01-01

    Objective:To investigate the diagnostic value of multidetector spiral CT (MSCT) in acute thoracolumbar spinal fracture and fracture-dislocation.Methods: CT imaging files of 152 consecutive traumatic patients with thoracolumbar fractures were retrospectively reviewed. MSCT scannings were performed with a collimation of 3-5 mm and a pitch of 5.5. The postprocessing included sagittal and coronal multiplannar reconstruction, and 3-D reconstruction.Result: There were 88 cases of compression fracture, 54 cases of burst fracture and 10 cases of fracasdislocation. Transverse images of MSCT could visualize all fractures directly and determine whether spinal canal was intact. Postprocessing image was helpful in depicting the displacement of fragment and orientation of dislocation.Conclusions: MSCT plays an important role in diagnosis and management of acute thoracolumbar spinal fracture and fracture-dislocation.

  19. Multidetector CT in emergency radiology: acute and generalized non-traumatic abdominal pain.

    Science.gov (United States)

    Paolantonio, Pasquale; Rengo, Marco; Ferrari, Riccardo; Laghi, Andrea

    2016-01-01

    Multidetector CT (MDCT) is an imaging technique that provides otherwise unobtainable information in the diagnostic work-up of patients presenting with acute abdominal pain. A correct working diagnosis depends essentially on understanding the individual patient's clinical data and laboratory findings. In haemodynamically stable patients with acute severe and generalized abdominal pain, MDCT is now the preferred imaging test and gives invaluable diagnostic information, also in unstable patients after stabilization. In this descriptive review, we focus our attention on acute, severe and generalized or undifferentiated non-traumatic abdominal pain. The main differential diagnoses are acute pancreatitis, gastrointestinal perforation, ruptured abdominal aneurysm and acute mesenteric ischaemia. We will provide radiologist readers with a technical guide to optimize MDCT imaging protocols and list the major CT signs essential to reach a correct diagnosis and guide the best treatment. PMID:26689097

  20. Multidetector CT of expected findings and complications after contemporary inguinal hernia repair surgery

    Science.gov (United States)

    Tonolini, Massimo

    2016-01-01

    Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285

  1. Lifetimes of superdeformed nuclei in the mass region A ∼150 with the Eurogam multidetector array

    International Nuclear Information System (INIS)

    This work concerns the study of the nuclear superdeformation phenomenon in the rare earth region (A ∼ 150). The superdeformed (SD) states in Gadolinium and Dysprosium isotopes were produced via heavy-ion induced reactions and studied with the EUROGAM EUROpean GAmma-ray Microscope) gamma multidetector array. Precise level attenuation method (DSAM). From the derived quadrupole moments, we find large differences in deformation between the yrast bands in neighbour nuclei explained in terms of the case of nuclei corresponding to an axis ratio of 2:1, the shell gaps are not fixed at a specific particle number and deformation. Furthermore the present results indicate that the deformations associated with identical bands are different supporting the picture that mass and deformation changes tend to compensate in SB bands with the same moments of inertia. (author)

  2. Performance comparison of multi-detector detection statistics in targeted compact binary coalescence GW search

    CERN Document Server

    Haris, K

    2016-01-01

    Global network of advanced Interferometric gravitational wave (GW) detectors are expected to be on-line soon. Coherent observation of GW from a distant compact binary coalescence (CBC) with a network of interferometers located in different continents give crucial information about the source such as source location and polarization information. In this paper we compare different multi-detector network detection statistics for CBC search. In maximum likelihood ratio (MLR) based detection approaches, the likelihood ratio is optimized to obtain the best model parameters and the best likelihood ratio value is used as statistic to make decision on the presence of signal. However, an alternative Bayesian approach involves marginalization of the likelihood ratio over the parameters to obtain the average likelihood ratio. We obtain an analytical expression for the Bayesian statistic using the two effective synthetic data streams for targeted search of non-spinning compact binary systems with an uninformative prior on...

  3. [Multidetector row CT in assessment of coronary artery calcification on hemodialisis].

    Science.gov (United States)

    Caro, P; Delgado, R; Dapena, F; Núñez, A

    2007-01-01

    Vascular calcification is a strong predictor of cardiovascular and all-cause mortality. Coronary artery calcification is more frequent, more extensive and progresses more rapidly in CKD than in general population. They are also considered a marker of coronary heart disease, with high prevalence and functional significance. It suggests that detection and surveillance may be worthwhile in general clinical practice. New non-invasive image techniques, like Multi-detector row CT, a type of spiral scanner, assess density and volume of calcification at multiple sites and allow quantitative scoring of vascular calcification using calcium scores analogous to those from electron-beam CT. We have assessed and quantified coronary artery calcification with 16 multidetector row CT in 44 patients on hemodialysis and their relationship with several cardiovascular risk factors. Coronary artery calcification prevalence was of 84 % with mean calcium score of 1580 +/- 2010 ( r 0-9844) with calcium score > 400 in 66% of patients. It was usually multiple, affecting more than two vessels in more than 50%. In all but one patient, left anterior descending artery was involved with higher calcium score level at right coronary artery. Advanced age, male, diabetes, smoking, more morbidity, cerebrovascular disease previous, and calcium-binders phosphate and analogous vitamin D treatment would seem to be associated with coronary artery calcification. Coronary artery calcification is very frequent and extensive, usually multiple and associated to modifiable risk factors in hemodialysis patients. Multi-detector-row CT seems an effective, suitable, readily applicable method to assess and quantify coronary artery calcification. PMID:18336102

  4. Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis

    OpenAIRE

    Salaffi, Fausto; Carotti, Marina; Ciapetti, Alessandro; Ariani, Alarico; Gasparini, Stefania; Grassi, Walter

    2013-01-01

    Background To investigate the performance of conventional radiography (CR) for the detection of bone erosions of wrist in rheumatoid arthritis (RA) using multidetector computed tomography (CT) as the reference method and to evaluate the validity of a computer-assisted manual segmentation (outlining) technique to quantify erosion volume on CT scans. Methods Twenty five RA patients and six controls underwent CT and radiographic evaluation of the dominant wrist on the same day. CT was performed ...

  5. Coronal multiplanar reconstruction view from isotropic voxel data sets obtained with multidetector-row CT. Assessment of detection and size of mediastinal and hilar lymph nodes

    International Nuclear Information System (INIS)

    To assess the detection and size of mediastinal and hilar lymph nodes by multiplanar reconstruction (MPR) view from isotropic voxel data sets obtained with multidetector-row computed tomography (MDCT). Thin-section CT of 27 patients with mediastinal or hilar lymph node swelling was obtained with a 25.6-cm field of view (FOV), 512 x 512 matrix, and two protocols: 0.5-mm collimation, 0.3-mm interval (Set A), and 2-mm collimation, 1-mm interval (Set B). MPR views with a 0.5-mm slice thickness were obtained from these two data sets. Postcontrast axial CT used 5-mm collimation (set C). Two observers evaluated the presence and cranio-caudal length of swollen lymph nodes. Two other board-certified chest radiologists evaluated all three sets and established a gold standard by consensus. The accuracy of detection was 76%, 73%, and 68% for sets A, B, and C, respectively. There was a significant difference between sets A and C (McNemar's test: p0.05). The cranio-caudal length of lymph nodes was significantly correlated with the gold standard only in set A (Pearson's correlation coefficient: r=0.53, p<0.05). Non-contrast enhanced coronal MPR views constructed from isotropic voxel data sets may be substituted for axial enhanced CT for the evaluation of mediastinal and hilar lymph nodes. (author)

  6. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

    International Nuclear Information System (INIS)

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against 15O-H2O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P CT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  7. CT findings of intraductal papillary neoplasm of the bile duct: Assessment with multiphase contrast-enhanced examination using multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H., E-mail: ogawa.hiroshi@h.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Japanese Red Cross Nagoya Daiichi Hospital, Nagoya (Japan); Nagasaka, T. [Department of Medical Technology, Nagoya University School of Health Sciences, Nagoya (Japan); Suzuki, K. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Ota, T. [Department of Radiology, Aichi Medical University Hospital, Nagakute Aichi (Japan); Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2012-03-15

    Aim: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. Materials and methods: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1 mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. Results: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20 mm (n = 32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n = 31), not hyperdense during the portal-venous and delayed phases (n = 36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n = 27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. Conclusions: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.

  8. Use of multidetector-row CT colonography for detection of colorectal neoplasia in patients referred via the Department of Health '2-week-wait' initiative

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A.; Halligan, S. E-mail: s.halligan@ic.ac.uk; Saunders, B.P.; Morley, S.; Riesewyk, C.; Atkin, W.; Bartram, C.I

    2003-11-01

    AIM: Patients referred under the Department of Health 2-week wait initiative with symptoms of colorectal cancer frequently undergo whole-colon examination. We investigated the use of computed tomography (CT) colonography as an alternative to colonoscopy in this scenario. MATERIALS AND METHODS: Fifty-four consecutive patients, referred via the 2-week wait initiative and scheduled for colonoscopy, consented to undergo multidetector CT colonography immediately before endoscopy. The site and morphology of any polyp or cancer detected by CT was noted and comparison made with subsequent colonoscopy. RESULTS: Colonoscopy detected polyps or cancer in 29 patients (53.7%). CT colonography prospectively detected 18 of 41 (44%) polyps of 1-5 mm, three of four (75%) polyps of 6-9 mm, four of four (100%) polyps 10 mm or larger, and five of six (83%) cancers. The missed cancer occurred early in the series and was a perceptive error. The overall sensitivity, specificity, positive predictive value and negative predictive value of CT colonography for cancer and polyps 10 mm or greater on a per patient basis were 90, 100, 100 and 98%, respectively. CT detected one renal cancer and one colonic cancer, initially missed due to incomplete colonoscopy. CONCLUSION: CT colonography is a robust technique for investigation of symptomatic patients. The learning curve must be overcome for optimal performance.

  9. Use of multidetector-row CT colonography for detection of colorectal neoplasia in patients referred via the Department of Health '2-week-wait' initiative

    International Nuclear Information System (INIS)

    AIM: Patients referred under the Department of Health 2-week wait initiative with symptoms of colorectal cancer frequently undergo whole-colon examination. We investigated the use of computed tomography (CT) colonography as an alternative to colonoscopy in this scenario. MATERIALS AND METHODS: Fifty-four consecutive patients, referred via the 2-week wait initiative and scheduled for colonoscopy, consented to undergo multidetector CT colonography immediately before endoscopy. The site and morphology of any polyp or cancer detected by CT was noted and comparison made with subsequent colonoscopy. RESULTS: Colonoscopy detected polyps or cancer in 29 patients (53.7%). CT colonography prospectively detected 18 of 41 (44%) polyps of 1-5 mm, three of four (75%) polyps of 6-9 mm, four of four (100%) polyps 10 mm or larger, and five of six (83%) cancers. The missed cancer occurred early in the series and was a perceptive error. The overall sensitivity, specificity, positive predictive value and negative predictive value of CT colonography for cancer and polyps 10 mm or greater on a per patient basis were 90, 100, 100 and 98%, respectively. CT detected one renal cancer and one colonic cancer, initially missed due to incomplete colonoscopy. CONCLUSION: CT colonography is a robust technique for investigation of symptomatic patients. The learning curve must be overcome for optimal performance

  10. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with {sup 15}O-H{sub 2}O PET

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Naya, Masanao [Hokkaido University Graduate School of Medicine, Department of Cardiovascular Medicine, Sapporo (Japan); Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Sasaki, Tsukasa [Hokkaido University Hospital, Department of Radiology, Sapporo (Japan); Katoh, Chietsugu [Hokkaido University Faculty of Health Sciences, Sapporo (Japan); Shirato, Hiroki [Hokkaido University Graduate School of Medicine, Department of Radiation Medicine, Sapporo (Japan)

    2014-07-15

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against {sup 15}O-H{sub 2}O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFR{sub CT} in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  11. Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT

    International Nuclear Information System (INIS)

    It is debated whether iso-osmolar and low-osmolar contrast media are associated with different incidences of contrast medium-induced nephropathy (CIN) in patients with renal insufficiency. To compare the incidence of CIN in children undergoing contrast-enhanced multidetector computer tomography (MDCT) with intravenous injection of low-osmolar (iobitridol, Xenetix registered 300) or an iso-osmolar (iodixanol, Visipaque registered 270) iodinated contrast medium. One hundred forty-six children with normal renal function were included in this multicenter trial and underwent contrast-enhanced MDCT. The primary endpoint was the relative change in creatinine clearance from 48 h pre- to 72 h postcontrast medium administration using a noninferiority analysis in the intent-to-treat (ITT, n = 128) and per protocol (n = 68) populations. Secondary endpoints were incidence of CIN, global image quality, diagnostic efficacy and clinical safety. In the ITT population, the noninferiority of iobitridol over iodixanol was demonstrated. CIN incidence was 4.8% (three cases) with iobitridol and 10.6% (seven cases) with iodixanol (not significant). No statistically significant differences were observed for the secondary endpoints. Comparable satisfactory safety profiles were confirmed for both contrast media, with no significant difference in the incidence of CIN in children with normal renal function. (orig.)

  12. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    International Nuclear Information System (INIS)

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  13. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  14. A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves

    OpenAIRE

    Habets, Jesse; Symersky, Petr; de Mol, Bas A. J. M.; Willem P Th M Mali; Leiner, Tim; Budde, Ricardo P.J.

    2011-01-01

    Multidetector-row CT is promising for prosthetic heart valve (PHV) assessment but retrospectively ECG-gated scanning has a considerable radiation dose. Recently introduced iterative reconstruction (IR) algorithms may enable radiation dose reduction with retained image quality. Furthermore, PHV image quality on the CT scan mainly depends on extent of PHV artifacts. IR may decrease streak artifacts. We compared image noise and artifact volumes in scans of mechanical PHVs reconstructed with conv...

  15. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction.