WorldWideScience

Sample records for 64-row multidetector computed

  1. 64-row multidetector computed tomography portal venography of gastric variceal collateral circulation

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM:To study characteristics of collateral circulation of gastric varices (GVs) with 64-row multidetector computer tomography portal venography (MDCTPV).METHODS:64-row MDCTPV with a slice thickness of 0.625 mm and a scanning field from 2 cm above the tracheal bifurcation to the lower edge of the kidney was performed in 86 patients with GVS diagnosed by endoscopy. The computed tomography protocol included unenhanced,arterial and portal vein phases. The MDCTPV was performed on an AW4.3 workstation. GVs were c...

  2. Characteristics of paraesophageal varices: A study with 64-row multidetector computed tomograghy portal venography

    Institute of Scientific and Technical Information of China (English)

    Li-Qin Zhao; Wen He; Guang Chen

    2008-01-01

    AIM:To identify the charactedsUcs of morphology,location and collateral circulation involved in paraesophageal varices (para-EV) of portal hypertension patients with 64-row multidetector computed tomograghy (MDCT).METHODS:Fifty-two of 501 patients with portal hypertensive cirrhosis accompanied with esophageal varices were selected for 64-row MDCT examination after the observation of para-EV.The CT protocol included unenhanced,arterial and portal phases with a slice thickness of 0.625 mm and a scanning field of 2 cm above the bifurcation to the lower edge of kidney.The CT portal venography (CTPV) was reformatted on AW4.3 workstation.The characteristics of origination,location,morphology and collateral circulation in para-EV were observed.RESULTS:Among the 52 cases of para-EV,50 showed the originations from the posterior branch of left gastric vein,while the others from the anterior branch.Fifty cases demonstrated their locations close to the esophagealgastric junction,and the other two cases were extended to the inferior bifurcation of the trachea.The circuitous pattern was observed in 16 cases,while reticulated pattern was seen in 36 cases.Collateral circulation identified 4 cases of single periesophageal varices (peri-EV) communication,3 cases of single hemiazygous vein,one case of single inferior vena cava,41 cases of mixed type (collateral communications of at least 2 of above mentioned types) and 3 cases of undetermined communications.Among all the cases,43 patients showed the communications between para-EV and peri-EV,while hemiazygous vein (43 cases) and inferior vena cava (5 cases) were also involved.CONCLUSION:Sixty-four-row multidetector computed tomograghy portal venography could display the location,morphology,origin,and collateral types of paraEV,which provides important and referable information for clinical management and disease prognosis.

  3. Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Chee Khoon LIEW; Kui Hian SIM; Rapaee ANNUAR; Tiong Kiam ONG; Sze Piaw CHIN; Tobias Seyfarth; Yean Yip FONG; Wei Ling CHAN; Choon Kiat ANG; Houng Bang LIEW

    2006-01-01

    Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF.

  4. Feasibility and accuracy of coronary imaging in elderly patients using the 64-row multi-detector computed tomography: a correlation study with conventional coronary angiography

    Institute of Scientific and Technical Information of China (English)

    Wei Ling CHAN; Kui Hian SIM; Chee Khoon LIEW; Sze Piaw CHIN; Tiong Kiam ONG; Seyfarth Tobias; Yean Yip FONG; Choon Kiat ANG; Houng Bang LIEW; Rapaee ANNUAR

    2006-01-01

    Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and accuracy of using 64-row multi-detector computed tomography (MDCT) in the assessment of coronary artery stenoses in elderly patients. Methods One hundred and fifty two patients with suspected or known coronary artery disease were divided into 4 groups according to their age (Group A: 40-49 years,n=34; Group B: 50-59 years, n=57; Group C: 60-69 years, n=48; Group D: 70 years and above; n=13). Coronary CT angiography (CTA) using a 64-row MDCT was performed and the findings were compared with that of conventional coronary angiography (CCA).Using axial images, multi-planar reconstructions (MPR) and maximum intensity projections (MIP), coronary segments of lumen diameter = 1.5mm were analyzed for the presence of significant stenosis (= 50% ). Results Percentages of poor image quality from coronary CTA preventing reliable correlations with CCA were 21%, 14%, 19% and 62% in Groups A to D respectively. Patients in Group D had significantly higher calcium scores compared with the other groups (P<0.001). In patients where CTA images were of acceptable quality, percentages of accurate correlations with CCA were 89.8%, 93.4%, 86.6% and 78.0% for Groups A to D respectively.There were no significant difference in serum creatinine, heart rate and contrast volume between the 4 groups. Conclusions The 64-row MDCT coronary angiography was less accurate and feasible for patients aged 70 years or above due to heavy coronary calcification and inability to perform a satisfactory breath-hold. However, a high diagnostic accuracy with the MDCT is possible in patients aged less than 70 years.

  5. Whole tumour quantitative measurement of first-pass perfusion of oesophageal squamous cell carcinoma using 64-row multidetector computed tomography: Correlation with microvessel density

    Energy Technology Data Exchange (ETDEWEB)

    Chen Tianwu, E-mail: twchenscu@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Sichuan Province Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637007 (China); Yang Zhigang, E-mail: yangzg6666@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Wang Qiling, E-mail: xiaohongmao99@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li Yuan, E-mail: dr.liyuan@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Qian Lingling, E-mail: moneylinglingch1999@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Chen Huijiao, E-mail: joan-ch@sohu.com [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2011-08-15

    Purpose: To assess correlations between whole tumour first-pass perfusion parameters obtained with 64-row multidetector computed tomography (MDCT), and microvessel density (MVD) in oesophageal squamous cell carcinoma. Materials and Methods: Thirty-one consecutive patients with surgically confirmed oesophageal squamous cell carcinomas were enrolled into our study. All the patients underwent whole tumour first-pass perfusion scan with 64-row MDCT. Perfusion parameters, including perfusion (PF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Postoperative tumour specimens were assessed for MVD. Pearson correlation coefficient tests were performed to determine correlations between each perfusion parameter and MVD. Results: Mean values for PF, PED, BV and TTP of the whole tumour were 28.85 {+-} 20.29 ml/min/ml, 23.16 {+-} 8.09 HU, 12.13 {+-} 5.21 ml/100 g, and 35.05 {+-} 13.85 s, respectively. Mean MVD in whole tumour at magnification (x200) was 15.75 {+-} 4.34 microvessel/tumour sample (vessels/0.723 mm{sup 2}). PED and BV were correlated with MVD (r = 0.651 and r = 0.977, respectively, all p < 0.05). However, PF and TTP were not correlated with MVD (r = 0.070 and r = 0.100, respectively, all p > 0.05). Conclusion: The BV value of first-pass perfusion CT could reflect MVD in oesophageal squamous cell carcinoma, and can be an indicator for evaluating the tumour angiogenesis.

  6. Multidetector-row CT with a 64-row amorphous silicon flat panel detector

    Science.gov (United States)

    Shapiro, Edward G.; Colbeth, Richard E.; Daley, Earl T.; Job, Isaias D.; Mollov, Ivan P.; Mollov, Todor I.; Pavkovich, John M.; Roos, Pieter G.; Star-Lack, Josh M.; Tognina, Carlo A.

    2007-03-01

    A unique 64-row flat panel (FP) detector has been developed for sub-second multidetector-row CT (MDCT). The intent was to explore the image quality achievable with relatively inexpensive amorphous silicon (a-Si) compared to existing diagnostic scanners with discrete crystalline diode detectors. The FP MDCT system is a bench-top design that consists of three FP modules. Each module uses a 30 cm x 3.3 cm a-Si array with 576 x 64 photodiodes. The photodiodes are 0.52 mm x 0.52 mm, which allows for about twice the spatial resolution of most commercial MDCT scanners. The modules are arranged in an overlapping geometry, which is sufficient to provide a full-fan 48 cm diameter scan. Scans were obtained with various detachable scintillators, e.g. ceramic Gd IIO IIS, particle-in-binder Gd IIO IIS:Tb and columnar CsI:Tl. Scan quality was evaluated with a Catphan-500 performance phantom and anthropomorphic phantoms. The FP MDCT scans demonstrate nearly equivalent performance scans to a commercial 16-slice MDCT scanner at comparable 10 - 20 mGy/100mAs doses. Thus far, a high contrast resolution of 15 lp/cm and a low contrast resolution of 5 mm @ 0.3 % have been achieved on 1 second scans. Sub-second scans have been achieved with partial rotations. Since the future direction of MDCT appears to be in acquiring single organ coverage per scan, future efforts are planned for increasing the number of detector rows beyond the current 64- rows.

  7. 64-row multi-dector computed tomography coronary image from a center with early experience: first illustration of learning curve

    Institute of Scientific and Technical Information of China (English)

    Sze Piaw CHIN; Tiong Kiam ONG; Wei Ling CHAN; Chee Khoon LIEW; M.Tobias Seyfarth; Fong Yean Yip ALAN; Houng Bang LIEW; Kui Hian SIM

    2006-01-01

    Background and objectives The recent joint ACCF/AHA clinical competence statement on cardiac imaging with multi-detector computed tomography recommended a minimum of 6 months training and 300 contrast examinations, of which the candidate must be directly involved in at least 100 studies. Whether this is adequate to become proficient in interpretation of coronary computed tomogsignificant coronary stenosis in a center with 1 year's experience using a 64-row scanner. Methods A total of 778 patients underwent contrast-enhanced CTA between January and December 2005. Out of these patients, 301 patients also underwent contrast-enhanced conventional coronary angiography (CCA). These patients were divided into 4 groups according to the time the examination was underwent. Group Q1: first quarter of the year (n=20), Group Q2: second quarter (n=128), Group Q3: third quarter (n=134), and Group Results The sensitivity, specificity, positive, and negative predictive values were Q1 - 64%, 89%, 49% and 94%, respectively; Q2 -79%, 96%, 74% and 97%, respectively; Q3 - 78%, 96%, 74%, 97%, respectively, and Q4 - 100% for all. Conclusions In a center with formal training and high caseload, our accuracy in CTA analysis reached a plateau after 6 months experience. Test-bolus protocols produce better image quality and can improve accuracy. New centers embarking on CTA will need to overcome an initial 6-month learning curve depending upon the caseload during which time they should consider correlation with CCA.

  8. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Snijder, Roland A.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Groningen (Netherlands)

    2013-01-15

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 {+-} 14.0 % for nodules of any density, and 26.4 {+-} 15.5 % for solid nodules, compared with 7.6 {+-} 8.5 % (P < 0.01) semi-automatically. In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  9. Imaging of Blood Flow in Cerebral Arteries with Dynamic Helical Computed Tomography Angiography (DHCTA) Using a 64-Row CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Pekkola, J.; Kangasniemi, M. (Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2009-08-15

    Background: Cerebral computed tomography angiography (CTA) depicts a structural image of intracranial arteries without providing much time-resolved information on blood flow dynamics. Current CT technology allows obtaining of rapidly repeated helical scans during the arterial contrast filling phase after an intravenous contrast injection. Purpose: To report our experience on dynamic CT imaging in determining the direction of contrast filling within proximal intracranial arteries of operated cerebral artery aneurysm patients. Such dynamic information can help detect vascular occlusion or severe spasm. The method is here referred to as dynamic helical CT angiography (DHCTA). Material and Methods: We retrospectively collected image and related technical data for 23 patients who underwent DHCTA and CTA during their first postoperative day after cerebral artery aneurysm surgery. For DHCTA, we had helically scanned a 4-cm tissue volume three times in succession with a 64-row CT scanner at intervals of 2.6 s during arterial contrast filling after an intravenous contrast injection. We assessed how well DHCTA succeeded in demonstrating the direction of contrast filling in the proximal intracranial arteries, evaluated clinically relevant structural information provided by DHCTA and CTA, and compared radiation doses for the two methods. Results: For 21 patients, DHCTA outlined the direction of contrast filling in proximal intracranial arteries. As to arterial spasm and residual filling of the operated aneurysm, CTA and DHCTA gave similar information. Radiation doses were higher (P<0.000001) for DHCTA than for CTA at 120 kV tube voltage. At 100 kV, the difference was smaller, but doses for DHCTA still exceeded (P<0.05) those for CTA. Conclusion: DHCTA gave dynamic information unobtainable with CTA and could prove useful in selected clinical settings

  10. Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors; Analyse der mehrphasigen 64-Zeilen-Multidetektor-Computertomographie zur praeoperativen angiographischen Evaluation potenzieller Lebendnierenspender

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D.; Andersen, K.; Kroepil, P.; Cohnen, M.; Moedder, U.; Jung, G. [Universitaetsklinikum Duesseldorf, Institut fuer Diagnostische Radiologie, Duesseldorf (Germany); Sandmann, W. [Universitaetsklinikum Duesseldorf, Klinik fuer Gefaesschirurgie und Nierentransplantation, Duesseldorf (Germany); Ivens, K. [Universitaetsklinikum Duesseldorf, Klinik fuer Nephrologie, Duesseldorf (Germany)

    2008-07-15

    Anatomical imaging and the ascertainment of any anomalies in the renal vessels and the ureters are essential in the planning of a kidney donation. The aim of the present study was to assess the value of 64-row multidetector CT in noninvasive examination of the renal vessels and ureters of potential living kidney donors. The evaluation embraced 63 living renal donors (LNS) who underwent preoperative CT examination from December 2004 to January 2007. The examinations were all carried out using a Somatom Sensation -Cardiac 64 (Siemens Medical Solutions, Germany). As well as CT angiography (CTA), a venous phase of the abdomen and a late phase after 15 min using low-dose technique were performed for CT urography (CTU). The radiological findings were compared with the surgical results, or with the angiograms in 2 cases. Sensitivity, specificity and both negative and positive predictive value were calculated. In the 63 (31 female, 32 male) donors CTA had a sensitivity of 100% in examination of the main and accessory renal arteries and of 98.3% when the venous and ureteric anatomy were assessed. The sensitivity of low-dose CTU was also 100%. The findings recorded in this study indicate that noninvasive preoperative planning with 64-row multidetector CTA and CTU is a reliable 'one-stop shopping' method of examination for potential living kidney donors. (orig.) [German] Die anatomische Darstellung und Erfassung moeglicher Anomalien der Nierengefaesse und Ureteren ist fuer die Planung einer Lebendnierenspende von essenzieller Bedeutung. Die vorliegende Untersuchung soll die Wertigkeit der nichtinvasiven Evaluation mit der 64-Zeilen-Multidetektor-CT untersuchen. In die Auswertung wurden 63 Lebendnierenspender (LNS) eingeschlossen, die im Zeitraum 12.2004 bis 01.2007 mit der CT praeoperativ untersucht wurden. Die Untersuchungen erfolgten mit einem Somatom-Sensation-Cardiac-64 (Siemens Medical Solutions, Deutschland). Neben einer CT-Angiographie (CTA) wurden eine

  11. Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring.

    Science.gov (United States)

    Pan, Zilai; Pang, Lifang; Li, Jianying; Zhang, Huan; Yang, Wenjie; Ding, Bei; Chai, Weimin; Chen, Kemin; Yao, Weiwu

    2011-04-01

    To evaluate the clinical value of a body mass index (BMI) based tube current (mA) selection method for obtaining consistent image quality with dose optimization in MDCT prospective ECG gated coronary calcium scoring. A formula for selecting mA to achieve desired image quality based on patient BMI was established using a control group (A) of 200 MDCT cardiac patients with a standard scan protocol. One hundred patients in Group B were scanned with this BMI-dependent mA for achieving a desired noise level of 18 HU at 2.5 mm slice thickness. The CTDIvol and image noise on the ascending aorta for the two groups were recorded. Two experienced radiologists quantitatively evaluated the image quality using scores of 1-4 with 4 being the highest. The image quality scores had no statistical difference (P = 0.71) at 3.89 ± 0.32, 3.87 ± 0.34, respectively, for groups A and B of similar BMI. The image noise in Group A had linear relationship with BMI. The image noise in Group B using BMI-dependent mA was independent of BMI with average value of 17.9 HU and smaller deviations for the noise values than in Group A (2.0 vs. 2.9 HU). There was a 35% dose reduction with BMI-dependent mA selection method on average with the lowest effective dose being only 0.35 mSv for patient with BMI of 18.3. A quantitative BMI-based mA selection method in MDCT prospective ECG gated coronary calcium scoring has been proposed to obtain a desired and consistent image quality and provide dose optimization across patient population.

  12. Correlation between US-PSV and 64-Row MDCTA with Advanced Vessel Analysis in the Quantification of 50–70% Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Matteo Stefanini

    2012-01-01

    Full Text Available Purpose. To correlate ultrasonographic peak systolic velocity (US-PSV and 64-row multidetector computed tomography angiography (MDCTA with advanced vessel analysis (AVA software in the quantification of 50–70% carotid artery stenosis. Materials and methods. 199 consecutive patients (247 arteries with internal carotid artery (ICA or third proximal bifurcation stenosis. Each patient was studied by duplex US (DUS and 64-row MDCTA with AVA software. Results. DUS showed PSV measurements less than 125 cm/s in 51 carotid stenosis and a value greater than this in 196 arteries. 64-row MDCTA AVA software showed a grade of stenosis less than 50% in 42 carotid arteries while a greater 70% was found in 4 carotid arteries; then, carotid arteries with stenosis percentage between 50% and 70% were 201. Linear regression analysis showed a good linear correlation (=0.88 between MDCTA-AVA software percentage stenosis and PSV: between 50% grade of stenosis and PSV value corresponding to 133,6 cm/sec and between 70% stenosis and PSV value corresponding to 268 cm/sec. The sensitivity, specificity, positive predictive value(PPV, negative predictive value(NPV of this analysis were 93%, 82%, 97%, 75%, respectively. Conclusion. Linear correlation between PSV data and grade of stenosis from 50% to 70% obtained with 64-row MDCTA AVA software. Main PSV value corresponding to 50% and 70% grade of stenosis at AVA analysis.

  13. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  14. Application of MPVR and TL-VR with 64-row MDCT in neonates with congenital EA and distal TEF

    Institute of Scientific and Technical Information of China (English)

    Yang Wen; Yun Peng; Ren-You Zhai; Ying-Zi Li

    2011-01-01

    AIM: To assess the application of multiple planar volume reconstruction (MPVR) and three-dimensional (3D) transparency lung volume rendering (TL-VR) with 64-row multidetector-row computed tomography (MDCT) in neonates with congenital esophageal atresia (EA) and distal tracheoesophageal fistula (TEF). METHODS: Twenty neonates (17 boys, 3 girls) with EA and distal TEF at a mean age of 4.6 d (range 1-16 d) were enrolled in this study. A helical scan of 64-row MDCT was performed at the 64 mm × 0.625 mm collimation. EA and TEF were reconstructed with MPVR and TL-VR, respectively. Initial diagnosis of EA was made by chest radiography showing the inserted catheter in the proximal blind-ended esophageal pouch. Manifestations of MDCT images were compared with the findings at surgery. RESULTS: MDCT showed the proximal and distal esophageal pouches in 20 cases. No significant difference was observed in gaps between the proximal and distal esophageal pouches detected by MPVR and TLVR. The lengths of gaps between the proximal and distal esophageal pouches detected by MPVR and TL-VR correlated well with the findings at surgery (R = 0.87, P < 0.001). The images of MPVR revealed the orifice of TEF in 13 cases, while TL-VR images showed the orifice of TEF in 4 cases. CONCLUSION: EA and distal TEF can be reconstructed using MPVR and TL-VR of 64-row MDCT, which is a noninvasive technique to demonstrate the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  15. Imaging findings of myocardial revascularization at multidetector computed tomography: where are the bypass grafts?: an iconographic essay

    Energy Technology Data Exchange (ETDEWEB)

    Ripari, Marcelo Targa; Santaniello, Rogerio; Sasdelli Neto, Roberto; Nomura, Cesar Higa; Chate, Rodrigo Caruso; Passos, Rodrigo Bastos Duarte; Kay, Fernando Uliana; Funari, Marcelo Buarque de Gusmao [Hospital Albert Einstein, Sao Paulo, SP (Brazil). Dept. of Imaging], e-mail: mtripari@uol.com

    2009-09-15

    Multidetector coronary computed tomography angiography is a precise method for evaluating post-coronary revascularization arterial and venous bypass grafts, and is somehow superseding coronary catheterization that is an invasive and more expensive technique. The present iconographic essay is aimed at anatomically demonstrating the bypass grafts most frequently utilized, how to differentiate between arterial and venous grafts and how to find them. The studies were performed in 64-row multidetector computed tomography equipment, with breath hold, controlled heart rate and appropriate protocols with later MPR, MIP and 3D reconstructions according to electrocardiogram. The localization of the bypass grafts and anastomoses at computed tomography studies focused on chest and coronary arteries may represent a difficulty in the images analysis by the radiologist who is not familiar with the matter, so the knowledge of the surgical techniques adopted and possible courses of the saphenous bypass grafts and arterial grafts can aid in the analysis of both studies, avoiding diagnostic errors. (author)

  16. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Chandrashekhar, Guruprasadh, E-mail: cguruprasadh@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Sodhi, Kushaljit Singh, E-mail: sodhiks@gmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Saxena, Akshay Kumar, E-mail: fatakshay@yahoo.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Rohit, Manoj Kumar, E-mail: rohitmanoj@gmail.com [Department of Pediatric Cardiology, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Departments of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India)

    2012-12-15

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  17. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  18. Multidetector computed tomography virtual hysterosalpingography in the investigation of the uterus and fallopian tubes

    Energy Technology Data Exchange (ETDEWEB)

    Carrascosa, Patricia [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina)], E-mail: patriciacarrascosa@diagnosticomaipu.com.ar; Baronio, Mariano [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina); Capunay, Carlos; Lopez, Elba Martin; Vallejos, Javier [Diagnostico Maipu, Av. Maipu 1668, Vicente Lopez B1602ABQ, Buenos Aires (Argentina); Borghi, Mario; Sueldo, Carlos; Papier, Sergio [CEGYR, Viamonte 1438, Capital Federal C1055ABB (Argentina)

    2008-09-15

    Objective: To compare the efficacy of multidetector CT virtual hysterosalpingography (MDCT-VH) with conventional X-ray hysterosalpingography (HSG) in the evaluation of patients with diagnosis of infertility. Methods: Sixty patients with diagnosis of infertility scheduled to perform a HSG, were evaluated with 16-row (n = 50) and 64-row (n = 10) MDCT-VH. In 35 patients the examination was performed without a tenaculum. The HSGs were carried out using standard technique. The HSG and MDCT-VH findings were compared. The duration for both examinations and patient discomfort were documented. The sensitivity and specificity of MDCT-VH for the detection of uterine pathology and tubal obstruction were calculated using the exact binomial method. Agreement between the two methods was assessed by the Cohen's kappa method (k). Results: The mean duration for MDCT-VH (16 and 64-rows) was 5 {+-} 3 min, whereas for HSG was 28 {+-} 3. The MDCT-VH without a tenaculum was the procedure with less patient discomfort. Sensitivity, specificity and inter-method agreement for the detection of uterine pathology were 100%, 92% and k = 0.92 for 16-row MDCT-VH and 100%, 100% and k = 1 for 64-row MDCT-VH, respectively. Sensitivity and specificity for detection of tubal obstruction were 80% and 80% for 16-row MDCT-VH and 100% and 100% for 64-row MDCT-VH, respectively; inter-method agreement for the visualization of the tubes was k = 0.54 for 16-row MDCT-VH and k = 1 for 64-row MDCT-VH. Conclusion: This study demonstrated the feasibility of evaluating the female reproductive system by MDCT-VH. 64-Row MDCT-VH could be an alternative diagnostic technique in the infertility workup algorithm. A larger study is in progress to validate these encouraging results.

  19. Tracheo-oesophageal fistula diagnosed with multidetector computed tomography.

    LENUS (Irish Health Repository)

    Hodnett, Pa

    2009-04-01

    This case highlights important issues in investigation of patients with suspected tracheo-oesophageal fistula including the value of multidetector computed tomography, the importance of thorough imaging evaluation when high clinical suspicion of tracheo-oesophageal fistula exists and the value of close interaction between radiologists and intensive care physicians in the investigation of these patients.

  20. Multidetector computed tomography in the preoperative staging of gastric adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Ricardo Hoelz de Oliveira; Penachim, Thiago Jose; Martins, Daniel Lahan; Andreollo, Nelson Adami; Caserta, Nelson Marcio Gomes, E-mail: rhobarros@hotmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2015-03-15

    Objective: To evaluate the role of multidetector computed tomography in the preoperative investigation of tumor invasion depth and lymph node and metastatic involvement according to the TNM classification, in patients with gastric adenocarcinoma. Materials and Methods: Fifty-four patients with biopsy-confirmed gastric cancer underwent preoperative staging with 64-channel multidetector computed tomography. Two independent radiologists analyzed the images and classified the findings. Sensitivity, specificity, accuracy and overall accuracy were calculated for each observer. The interobserver agreement was also evaluated. Results: The accuracy in the classification of categories T ranged from 74% to 96% for observer 1 and from 80% to 92% for observer 2. The overall accuracy was 70% for both observers. The weighted kappa index was 0.75, consistent with a significant interobserver agreement. The accuracy in the classification of lymph node involvement (category N) ranged from 55% to 79% for observer 1 and from 73% to 82% for observer 2. The evaluation of metastatic involvement showed an overall accuracy of 89.6% for both observers. Conclusion: 64-channel multidetector computed tomography demonstrated clinically relevant accuracy in the preoperative staging of gastric adenocarcinoma as regards invasion depth (T category) and metastatic involvement (M category). (author)

  1. Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults

    Directory of Open Access Journals (Sweden)

    João Palas

    2014-01-01

    Full Text Available Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  2. Multidetector computer tomography: evaluation of blunt chest trauma in adults.

    Science.gov (United States)

    Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel

    2014-01-01

    Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.

  3. Total body height estimation using sacrum height in Anatolian Caucasians: multidetector computed tomography-based virtual anthropometry

    Energy Technology Data Exchange (ETDEWEB)

    Karakas, Hakki Muammer [Inonu University Medical Faculty, Turgut Ozal Medical Center, Department of Radiology, Malatya (Turkey); Celbis, Osman [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Forensic Medicine, Malatya (Turkey); Harma, Ahmet [Inonu University Medical Faculty Turgut Ozal Medical Center, Department of Orthopaedics and Traumatology, Malatya (Turkey); Alicioglu, Banu [Trakya University Medical Faculty, Department of Radiology, Edirne (Turkey); Trakya University Health Sciences Institute, Department of Anatomy, Edirne (Turkey)

    2011-05-15

    Estimation of total body height is a major step when a subject has to be identified from his/her skeletal structures. In the presence of decomposed skeletons and missing bones, estimation is usually based on regression equation for intact long bones. If these bones are fragmented or missing, alternative structures must be used. In this study, the value of sacrum height (SH) in total body height (TBH) estimation was investigated in a contemporary population of adult Anatolian Caucasians. Sixty-six men (41.6 {+-} 14.9 years) and 43 women (41.1 {+-} 14.2 years) were scanned with 64-row multidetector computed tomography (MDCT) to obtain high-resolution anthropometric data. SH of midsagittal sections was electronically measured. The technique and methodology were validated on a standard skeletal model. Sacrum height was 111.2 {+-} 12.6 mm (77-138 mm) in men and 104.7 {+-} 8.2 (89-125 mm) in women. The difference between the two sexes regarding SH was significant (p < 0.0001). SH did not significantly correlate with age in men, whereas the correlation was significant in women (p < 0.03). The correlation between SH and the stature was significant in men (r = 0.427, p < 0.0001) and was insignificant in women. For men the regression equation was [Stature = (0.306 x SH)+137.9] (r = 0.54, SEE = 56.9, p < 0.0001). Sacrum height is not susceptible to sex, or to age in men. In the presence of incomplete male skeletons, SH helps to determine the stature. This study is also one of the initial applications of MDCT in virtual anthropometric research. (orig.)

  4. 64-row MDCT perfusion of head and neck squamous cell carcinoma: technical feasibility and quantitative analysis of perfusion parameters

    Energy Technology Data Exchange (ETDEWEB)

    Faggioni, Lorenzo; Neri, Emanuele; Cerri, Francesca; Picano, Eugenia; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Pisa (Italy); Seccia, Veronica; Muscatello, Luca; Franceschini, Stefano Sellari [University of Pisa, Division of Otorhinolaryngology, Pisa (Italy)

    2011-01-15

    To evaluate the technical feasibility of 64-row computed tomography (CT) quantitative perfusion imaging of head and neck squamous cell carcinoma (SCC). Twenty-nine patients with a total of 29 pathologically proven SCC underwent a cine-mode CT perfusion acquisition covering the lesion site. The acquisition started 10 s after intravenous injection of iodinated contrast material and lasted 50 s. On a dedicated workstation, regions of interest (ROI) were traced within the SCC, on a healthy portion of tissue (H), and on the ipsilateral sternocleidomastoid muscle (M). Blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability-surface product (PS) were calculated. In SCC, BF, BV and PS were higher compared with H (p < 0.0001, p = 0.002 and p = 0.004, respectively) and M (p < 0.0001). Conversely, MTT was lower in SCC than in H (p = 0.0009) and M (p = 0.0003). All datasets were free from substantial motion artefacts and ROI misregistration phenomena. No substantial discomfort or adverse events were experienced by any of the patients. 64-row CT quantitative perfusion imaging allows head and neck SCC to be distinguished from normal tissues. (orig.)

  5. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  6. Utility of 64-row MDCT in assessment of neonates with congenital EA and distal TEF

    Directory of Open Access Journals (Sweden)

    Hosam El-Deen Galal Mohamed El-Malah

    2015-12-01

    Conclusion: Preoperative MDCT scan with MPVR, 3D TL-VR of 64-row MDCT which is a noninvasive technique could provide more accurate information about the assessment of the origin of the fistula, the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  7. Visibility of Sutures of the Orbit and Periorbital Region Using Multidetector Computed Tomography

    OpenAIRE

    2014-01-01

    Objective Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Materials and Methods Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube...

  8. Value of Multidetector Computed Tomography in Assessing Blunt Multitrauma Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ahvenjaervi, L.; Mattila, L.; Ojala, R.; Tervonen, O. [Oulu Univ. Hospital (Finland). Dept. of Diagnostic Radiology

    2005-04-01

    Purpose: To find out if multidetector computed tomography (MDCT), using a dedicated trauma protocol, provides sufficient diagnostic information of the injuries of blunt multitrauma patients to enable the planning of treatment for all body compartments. Material and Methods: One-hundred-and-thirty-three patients exposed to high-energy trauma were referred and scanned with the standardized MDCT multitrauma protocol. The imaging protocol consisted of axial scanning of the head and helical scanning of the facial bones, cervical spine, thorax, abdomen, and pelvis. The scanning times were 12 s for the head, 19-21 s for the facial bones and cervical spine (1 mm collimation), and 32-50 s for the thorax, abdomen, and pelvis (2 mm collimation). One-hundred-and-forty milliliters of non-iodinated contrast material (300 mg I/ml) was administered intravenously at 3 ml/s. Results: Ninety-nine of the patients (74%) had at least one finding consistent with trauma. The most frequent findings were in the thorax in 58 patients (44%). Nineteen false-negative findings and two false-positive findings were made. The overall sensitivity of MDCT was 94%, specificity 100%, and accuracy 97%. Conclusion: MDCT is accurate in the assessment of blunt multitrauma patients. The decision to treat the patient can be made on the basis of MDCT with a reasonable level of certainty.

  9. Multidetector Computed Tomography of Cervical Spine Fractures in Ankylosing Spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Koivikko, M.P.; Kiuru, M.J.; Koskinen, S.K. [Helsinki Univ. Central Hospital, Toeoeloe Trauma Center (Finland). Dept. of Radiology

    2004-11-01

    Purpose: To analyze multidetector computed tomography (MDCT) cervical spine findings in trauma patients with advanced ankylosing spondylitis (AS). Material and Methods: Using PACS, 2282 cervical spine MDCT examinations requested by emergency room physicians were found during a period of 3 years. Of these patients, 18 (16 M, aged 41-87, mean 57 years) had advanced AS. Primary imaging included radiography in 12 and MRI in 11 patients. Results: MDCT detected one facet joint subluxation and 31 fractures in 17 patients: 14 transverse fractures, 8 spinous process fractures, 2 Jefferson's fractures, 1 type I and 2 type II odontoid process fractures, and 1 each: atlanto-occipital joint fracture and C2 laminar fracture plus isolated transverse process and facet joint fractures. Radiographs detected 48% and MRI 60% of the fractures. MRI detected all transverse and odontoid fractures, demonstrating spinal cord abnormalities in 72%. Conclusion: MDCT is superior to plain radiographs or MRI, showing significantly more injuries and yielding more information on fracture morphology. MRI is valuable, however, in evaluating the spinal cord and soft-tissue injuries. Fractures in advanced AS often show an abnormal orientation and are frequently associated with spinal cord injuries. In these patients, for any suspected cervical spine injuries, MDCT is therefore the imaging modality of choice.

  10. Multidetector computed tomography findings of spontaneous renal allograft ruptures

    Energy Technology Data Exchange (ETDEWEB)

    Basaran, C. [Department of Radiology, Baskent University Faculty of Medicine, Ankara (Turkey)], E-mail: ceylab@baskent-ank.edu.tr; Donmez, F.Y.; Tarhan, N.C.; Coskun, M. [Department of Radiology, Baskent University Faculty of Medicine, Ankara (Turkey); Haberal, M. [Department of General Surgery, Baskent University Faculty of Medicine, Ankara (Turkey)

    2009-05-15

    Aim: To describe the characteristics of spontaneous renal allograft rupture using multidetector computed tomography (MDCT). Method: Five patients with spontaneous renal allograft rupture, as confirmed by pathologic examination, were referred to our institution between 1985 and 2008. The clinical records and preoperative MDCT findings of the patients were studied retrospectively. Results: Clinical and/or histological findings were consistent with acute rejection in all cases. Using MDCT, disruption of the capsular integrity and parenchymal rupture was seen in four patients. Four of the five patients showed decreased enhancement and swollen grafts. Perirenal (n = 4), subcapsular (n = 1), and intraparenchymal (n = 1) haematomas were also seen. In the patient with an intraparenchymal haematoma there was no disruption of capsular integrity, but capsular irregularities were seen near the haematoma. Conclusion: MDCT is a useful investigative tool for the evaluation of suspected spontaneous renal allograft rupture. As well as a swollen graft, disruption of the capsule, parenchyma, and/or haematoma should prompt the radiologist to consider this diagnosis.

  11. Multidetector computed tomography in acute lower gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    John Palma

    2010-11-01

    Full Text Available John Palma, Marius Mihaila, Frank PilleulDépartement de Radiologie Digestive et des Urgences, Hôpital Edouard Herriot, Hospices Civils de Lyon, CHU, Lyon, FranceBackground: The aim of this study is to evaluate multidetector computed tomography (MDCT in acute massive lower gastrointestinal bleeding, with endoscopy and surgery as reference examinations.Methods: A single-center retrospective study involving 34 patients with acute massive lower gastrointestinal bleeding was carried out. All patients were evaluated by MDCT scan then endoscopic or surgical examinations. Sensitivity, specificity, and positive and negative predictive values of MDCT scan were calculated using the extravasation of the contrast agent as the main criterion.Results: Extravasation of the contrast agent was found in 30 of 34 patients (88%. The bleeding site seen on CT was always the same as on endoscopic or surgical examinations (100%. Sensitivity of MDCT scan was 94%, specificity 100%, positive predictive value 100%, and negative predictive value 50% (P < 0.001. Twelve diverticulum bleedings were seen on MDCT scan compared with 13 (92% on endoscopic or surgical examinations. Angiodysplasia was overestimated by MDCT scan.Conclusion: MDCT scan appears to be an excellent tool to find and localize the bleeding site in cases of acute massive lower gastrointestinal disease.Keywords: MDCT, acute lower gastrointestinal bleeding, extravasation, contrast agent

  12. Evaluation of left renal vein entrapment using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Poyraz, Ahmet K.; Onur, Mehmet R. [Dept. of Radiology, Firat Univ. School of Medicine, Elazig (Turkey)], e-mail: akursadpoyraz@yahoo.com.tr; Firdolas, Fatih [Dept. of Urology, Firat Univ. School of Medicine, Elazig (Turkey); Kocakoc, Ercan [Dept. of Radiology, Bezmialem Vakif Univ., School of Medicine, Istanbul (Turkey)

    2013-03-15

    Background: Nutcracker syndrome, also called left renal vein entrapment syndrome, is a cause of non-glomerular hematuria with difficulties in diagnosis. Multidetector computed tomography (MDCT) is a powerful tool to prevent unnecessary diagnostic procedures. Purpose: To retrospectively determine the prevalence of nutcracker phenomenon and nutcracker syndrome seen in MDCT in consecutive patients. Material and Methods: The institutional review board approved the study and waived the requirement for informed consent. Abdominal contrast-enhanced MDCT scans were reviewed from 1000 consecutive patients. MDCT scan assessment included renal vein diameter measurements and evaluation for the presence of anterior or posterior left renal vein entrapment. Electronic medical records and urine analysis reports of patients with left renal vein entrapment were reviewed. Student's t test was used to assess differences in renal vein diameter in patients with left renal vein entrapment. Results: Left renal vein entrapment was observed in 10.9% (109), retroaortic left renal vein in 6.5% (65), entrapment of left renal vein between superior mesenteric artery and aorta in 4.1% (41), and circumaortic left renal vein in 0.3% (3) of patients. Mean diameters of right (8.8 {+-} 1.9 mm) and unentrapped left (8.9 {+-} 1.8 mm) renal veins were not significantly different (P = 0.1). The mean diameter of anterior entrapped left renal veins (10.3 {+-} 2 mm) was significantly greater (P = 0.04) than contralateral renal veins (8.6 {+-} 2.1 mm) in their widest portion. In 8.8% of patients with the left renal vein entrapment, urine analysis showed isomorphic hematuria or proteinuria with no other known cause. Varicocele and pelvic congestion were seen in 5.5% of patients with the left renal vein entrapment. Conclusion: Left renal vein entrapment is not a rare entity and renal nutcracker phenomenon might be underdiagnosed.

  13. The story of 12 Chachapoyan mummies through multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Klaus M., E-mail: klaus.friedrich@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Nemec, Stefan, E-mail: stefan.nemec@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Czerny, Christian, E-mail: christian.czerny@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Fischer, Helga, E-mail: helga.fischer@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Plischke, Sonja, E-mail: sonja.plischke@akhwien.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Gahleitner, Andre, E-mail: andre.gahleitner@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Viola, Thomas Bence, E-mail: bence.viola@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Imhof, Herwig, E-mail: herwig.imhof@meduniwien.ac.at [Medical University Vienna, Department of Radiology, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Seidler, Horst, E-mail: horst.seidler@univie.ac.at [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria); Guillen, Sonja [University of Vienna, Department of Anthropology, Althanstrasse 14, A-1091 Vienna (Austria)

    2010-11-15

    Objective: To assess the imaging findings in Chachapoyan mummies of Peru through multidetector computed tomography (MDCT). Materials and methods: Twelve human mummies and three burial objects from Laguna de los Condores, Peru, about 500-1000 years old, were studied, using a MDCT unit. In addition to the standard whole-body acquisitions, high-resolution scans from areas of particular interest were acquired individually (e.g., temporal bone, teeth). Results: Eight mummies were female, three male, and sex was indeterminable in one mummy; the age of the mummies included newborn, 0.7 years, 2.5 years, 13 years, 13 years, 16 years, and six between 20 and 40 years old. The stature of the mummies was reconstructed (mean {+-} standard deviation; adults: 145 {+-} 14 cm, adolescents: 116 {+-} 17 cm, 2.5 years old child: 72 cm, newborns: 41 {+-} 3 cm). Dental conditions were compromised in seven and excellent in five mummies. Besides a dislocation of the ossicles, temporal bones and ears were normal in all mummies. An occipital osteoma, a tuberculous spondylodiscitis, and also probable tuberculous erosions at one tarsal joint and one sacral bone, osteoarthritis or tuberculous affection of a sacroiliac joint, as well as five cases of pulmonary tuberculosis were observed. Ten mummies were buried in the fetal position, two were found packaged in bundles; the burial technique was studied in detail. A necklace was found with one mummy. The added burial objects were identified as skeletal parts of two leopardis pardalis and one lagothrix flavicauda. Conclusions: MDCT non-invasively revealed information about age, sex, stature, diseases, burial practices and other cultural aspects of the Chachapoyas.

  14. Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Zacho, Mette; Lilleoer, Nikolaj Thomas; Kelbaek, Henning

    2012-01-01

    The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related...

  15. Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves

    NARCIS (Netherlands)

    Symersky, P.; Budde, R.P.; Prokop, M.; Mol, B.A. de

    2011-01-01

    BACKGROUND AND AIM OF THE STUDY: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). METHODS: Bjor

  16. Multidetector-Row Computed Tomography Imaging Characteristics of Mechanical Prosthetic Valves

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Prokop, Mathias; de Mol, Bas A. J. M.

    2011-01-01

    Background and aim of the study: Electrocardiogram-gated multidetector-row computed tomography (MDCT) imaging may aid in the evaluation of prosthetic valve dysfunction. A pulsatile in vitro model was developed to study the MDCT imaging characteristics of mechanical heart valves (MHVs). Methods: Bjor

  17. Communication between the right and circumflex coronary arteries discovered incidentally by multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Se Hwan; Kim, Eui Jong; Woo, Jong Shin; Kim, Soo Joong; Youn, Hyo Chul; Oh, Joo Hyeong [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2016-09-15

    Intercoronary communication is a rare congenital coronary anomaly. We present a case of a 48-year-old man with an incidentally discovered communication between the right and circumflex coronary arteries, who was admitted with chest tightness and exertional dyspnea. The initial diagnosis was made using electrocardiogram-gated multidetector computed tomography.

  18. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    2005-01-01

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic mo

  19. Multidetector computed tomography pulmonary angiography in childhood acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Chowdhury, Shahryar M. [Medical University of South Carolina, Department of Pediatrics, Charleston, SC (United States); Fox, Mary A. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Pulmonary embolism is a life-threatening condition affecting people of all ages. Multidetector row CT pulmonary angiography has improved the imaging of pulmonary embolism in both adults and children and is now regarded as the routine modality for detection of pulmonary embolism. Advanced CT pulmonary angiography techniques developed in recent years, such as dual-energy CT, have been applied as a one-stop modality for pulmonary embolism diagnosis in children, as they can simultaneously provide anatomical and functional information. We discuss CT pulmonary angiography techniques, common and uncommon findings of pulmonary embolism in both conventional and dual-energy CT pulmonary angiography, and radiation dose considerations. (orig.)

  20. Hemobilia in a child due to right hepatic artery pseudoaneurysm: Multidetector-row computed tomography demonstration

    Directory of Open Access Journals (Sweden)

    Nisar A Wani

    2011-01-01

    Full Text Available We present a case of a 12-year-old boy who developed upper gastrointestinal bleeding in the form of hematemesis and melena 1 month after blunt trauma to liver. Computed tomography (CT angiography with multidetector-row CT demonstrated pseudoaneurysm of right hepatic artery related to old liver laceration to be the cause of the bleeding. Pseudoaneurysm was resected using the roadmap provided by CT angiography findings.

  1. Post-operative evaluation of endo vascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Thomaz, Fabiana Barroso; Magalhaes, Fabio Vargas; Magalhaes, Isabela Ferreira de; Caramalho, Monica Ferreira; Kuroki, Iugiro Roberto [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil). Unit of Computed Tomography]. E-mail: fabianabt@terra.com.br; Lopez, Gaudencio Espinosa [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). School of Medicine. Dept. of Surgery; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteri, RJ (Brazil). Dept. of Radiology; Domingues, Romeu Cortes [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2008-07-15

    Objective: The present study was aimed at evaluating endo vascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography. Materials and methods: Multidetector computed tomography angiography studies of 166 patients were retrospectively analyzed. The sample included 137 men and 29 women with mean age of 73 years who had undergone endovascular treatment for abdominal aortic aneurysm in the period between June 2005 and August 2006. Images were acquired in a 64-channel multidetector tomograph adopting the following parameters: 0.625 mm collimation, pitch 0.6-1, 300-400 mAs, and 120 kV. A nonionic iodinated contrast agent (350 mg/ml) was injected by infusion pump at a rate of 4 ml/s to 5 ml/s and a variable amount of 70 ml to 100 ml. The studies were evaluated for the presence of complications. Results: Among the 166 cases, 93 patients did not present complications and 73 presented the following findings: endoleak (n=37), circumferential thrombosis (n=29), angulation (n=17), presence of collection at the puncture site (n=10), graft migration (n=7), dissection of access vessels (n=7) and occlusion (n=6). Conclusion: In summary, endoleak was the most prevalent complication in the present series, with type II endoleak being most frequently found. (author)

  2. Advances and perspectives in lung cancer imaging using multidetector row computed tomography.

    Science.gov (United States)

    Coche, Emmanuel

    2012-10-01

    The introduction of multidetector row computed tomography (CT) into clinical practice has revolutionized many aspects of the clinical work-up. Lung cancer imaging has benefited from various breakthroughs in computing technology, with advances in the field of lung cancer detection, tissue characterization, lung cancer staging and response to therapy. Our paper discusses the problems of radiation, image visualization and CT examination comparison. It also reviews the most significant advances in lung cancer imaging and highlights the emerging clinical applications that use state of the art CT technology in the field of lung cancer diagnosis and follow-up.

  3. Bosniak classification of renal cystic lesions according to multidetector computed tomography findings; Classificacao de Bosniak das lesoes cisticas renais segundo achados na tomografia computadorizada multidetectores

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Christiana Maia Nobre Rocha de; Padilha, Igor Gomes; Farias, Lucas de Padua Gomes de; Rocha, Milzi Sarmento da, E-mail: maiachristiana@globo.com [Universidade Federal de Alagoas (UFAL), Maceio, AL (Brazil); Maranhao, Carol Pontes de Miranda; Santos, Carla Jotta Justo dos [Clinica de Medicina Nuclear e Radiologia de Maceio (MedRadiUS), Maceio, AL (Brazil)

    2014-03-15

    Renal cystic lesions are usually diagnosed in the radiologists' practice and therefore their characterization is crucial to determine the clinical approach to be adopted and prognosis. The Bosniak classification based on computed tomography findings has allowed for standardization and categorization of lesions in increasing order of malignancy (I, II, IIF, III and IV) in a simple and accurate way. The present iconographic essay developed with multidetector computed tomography images of selected cases from the archives of the authors' institution, is aimed at describing imaging findings that can help in the diagnosis of renal cysts. (author)

  4. Multidetector computed tomographic and magnetic resonance enterography in children: state of the art.

    Science.gov (United States)

    Hammer, Matthew R; Podberesky, Daniel J; Dillman, Jonathan R

    2013-07-01

    Advanced multidetector computed tomographic and magnetic resonance imaging techniques (CT and MR enterography, respectively), designed to provide detailed images of the bowel and mesentery, can be successfully performed in children of all ages, frequently without sedation. Cross-sectional enterography allows for noninvasive diagnosis, detection of various disease-related complications and extraintestinal manifestations, and monitoring of bowel-wall inflammation in pediatric inflammatory bowel disease (IBD). This article provides a contemporary review of CT and MR enterography in the pediatric population, including up-to-date techniques and clinical applications. A range of bowel abnormalities is illustrated, with an emphasis on IBD and its many abdominopelvic manifestations.

  5. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  6. Multidetector computed tomography of urolithiasis. Technique and results; Multidetektor-Computertomografie der Urolithiasis. Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Karul, M.; Regier, M. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Radiologie und Endoskopie; Heuer, R. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Zentrum fuer Operative Medizin

    2013-02-15

    The diagnosis of acute urolithiasis results from unenhanced multidetector computed tomography (MDCT). This test analyses the functional and anatomical possibility for passing an ureteral calculi, the localization and dimension of which are important parameters for further therapy. Alternatively chronic urolithiasis could be ruled out by magnetic resonance urography (MRU). MRU is the first choice especially in pregnant women and children because of radiation hygiene. Enhanced MDCT must be emphasized as an alternative to intravenous urography (IVU) for diagnosis of complex drainage of urine and suspected disorder of the involved kidney. This review illustrates the principles of different tests and the clinical relevance thereof. (orig.)

  7. Multidetector computed tomography-spectrum of blunt chest wall and lung injuries in polytraumatized patients

    Energy Technology Data Exchange (ETDEWEB)

    Peters, S., E-mail: soeren.peters@rub.d [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany); Nicolas, V.; Heyer, C.M. [Department of Radiology and Nuclear Medicine, BG Universitaetsklinikum Bergmannsheil, Buerkle-de-la-Camp-Platz 1, 44789 Bochum (Germany)

    2010-04-15

    Accidental injuries are the leading cause of death in the 15 to 44-year-old age group. Blunt chest trauma is often encountered in these patients and is associated with a mortality of up to 25%. Although conventional radiography still plays an important role in the initial emergency room setting, for follow-up in the intensive care unit, multidetector computed tomography has established itself as the standard imaging method for the evaluation of chest trauma patients. The following review presents salient radiological findings of the chest wall and shoulder girdle, thoracic spine, pleural space, and lung in polytraumatized patients.

  8. Multi-detector computed tomography imaging of large airway pathology:A pictorial review

    Institute of Scientific and Technical Information of China (English)

    Tejeshwar Singh Jugpal; Anju Garg; Gulshan Rai Sethi; Mradul Kumar Daga; Jyoti Kumar

    2015-01-01

    The tracheobronchial tree is a musculo-cartilagenous framework which acts as a conduit to aerate the lungs and consequently the entire body. A large spectrum of pathological conditions can involve the trachea and bronchial airways. These may be congenital anomalies, infections, post-intubation airway injuries, foreign body aspiration or neoplasms involving the airway. Appropriate management of airway disease requires an early and accurate diagnosis. In this pictorial essay review, we will comprehensively describe the various airway pathologies and their imaging findings by multi-detector computed tomography.

  9. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography.

    Science.gov (United States)

    Shergill, Arvind K; Maraj, Tishan; Barszczyk, Mark S; Cheung, Helen; Singh, Navneet; Zavodni, Anna E

    2015-01-01

    Blunt and penetrating cardiovascular (CV) injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT) has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center.

  10. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography

    Directory of Open Access Journals (Sweden)

    Arvind K Shergill

    2015-01-01

    Full Text Available Blunt and penetrating cardiovascular (CV injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center.

  11. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Onbas, Omer; Aliagaoglu, Cihangir; Calikoglu, Cagatay; Kantarci, Mecit; Atasoy, Mustafa; Alper, Fatih [Ataturk University, Erzurum (Turkmenistan)

    2006-03-15

    Neurofibromatosis type 1 disease if characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography.

  12. Absence of a sphenoid wing in neurofibromatosis type 1 disease: imaging with multidetector computed tomography.

    Science.gov (United States)

    Onbas, Omer; Aliagaoglu, Cihangir; Calikoglu, Cagatay; Kantarci, Mecit; Atasoy, Mustafa; Alper, Fatih

    2006-01-01

    Neurofibromatosis type 1 disease is characterized by pigmented cutaneous lesions and generalized tumors of a neural crest origin and it may affect all the systems of the human body. Sphenoid dysplasia is one of the characteristics of this syndrome and it occurs in 5-10% of the cases; further, abnormalities of the sphenoid wings are often considered pathognomonic. However, complete agenesis of a sphenoid wing is very rare. We report here on an unusual case of neurofibromatosis type 1 disease with the associated absence of a sphenoid wing that was diagnosed by using multidetector computed tomography.

  13. Prognostic implications of nonobstructive coronary plaques in patients with non-ST-segment elevation myocardial infarction: a multidetector computed tomography study

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Kühl, Jørgen T;

    2011-01-01

    We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events.......We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events....

  14. Contrast-enhanced ultrasound vs multidetector-computed tomography for detecting liver metastases in colorectal cancer: a prospective, blinded, patient-by-patient analysis

    DEFF Research Database (Denmark)

    Rafaelsen, S R; Jakobsen, A

    2011-01-01

    This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer.......This study compared the sensitivity and specificity of contrast-enhanced ultrasound (CEUS) and multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer....

  15. Calcium score of small coronary calcifications on multidetector computed tomography

    DEFF Research Database (Denmark)

    Groen, J M; Kofoed, K F; Zacho, M;

    2013-01-01

    Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which ena...

  16. Sex estimation from sternal measurements using multidetector computed tomography.

    Science.gov (United States)

    Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur

    2014-12-01

    We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.

  17. Comparison between clinical indicators of transmembrane oxygenator thrombosis and multidetector computed tomographic analysis.

    Science.gov (United States)

    Panigada, Mauro; L'Acqua, Camilla; Passamonti, Serena Maria; Mietto, Cristina; Protti, Alessandro; Riva, Roberto; Gattinoni, Luciano

    2015-04-01

    This study aims to assess whether multidetector computed tomography (MDCT) could accurately confirm the clinical suspicion of transmembrane oxygenator thrombosis (MOT) during extracorporeal membrane oxygenation (ECMO). Twenty-seven oxygenators were examined using MDCT at the end of patient treatment. Transmembrane oxygenator thrombosis was suspected in 15 of them according to the presence of at least 2 of the following clinical indicators: (1) increase in d-dimer, (2) decrease in platelet count, (3) decrease in oxygenator performance, and (4) presence of clots on the surface of the oxygenator. Transmembrane oxygenator thrombosis was confirmed by MDCT in 5 (33%) of them. Transmembrane oxygenator thrombosis was unexpectedly found in 5 (41%) of the remaining 12 oxygenators not suspected for MOT. Eight (80%) of these oxygenators had clots accounting for less than 1% of total volume. Clots were mainly detectable at the apical corner of the oxygenator, most likely due to greater blood stasis. We found a significant increase in d-dimer and in membrane oxygenator shunt and a decrease in platelet count from the start to the discontinuation of ECMO. Hemostatic abnormalities significantly reverted 48 hours after oxygenator removal, suggesting the role of ECMO in activation of the coagulation cascade. Multidetector computed tomographic scan could not accurately confirm the clinical suspicion of MOT.

  18. Visibility of sutures of the orbit and periorbital region using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gufler, Hubert; Preis, Markus; Koesling, Sabrina [Dept. of Diagnostic Radiology, Martin-Luther-University Halle-Wittenberg, Halle (Germany)

    2014-12-15

    Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube current from 25 to 370 mAs, depending on the CT indication. The visibility of sutures was estimated according to a 4-point scale from 'not visible to well visible' The chi-squared test was used to test the association of the visibility of sutures with the slice thickness, tube current, and age of patients. Statistical significance was assumed at p < 0.05. Overall, best visibility was found for the sutura frontozygomatica (98%), sutura frontonasalis (88.5%), and sutura sphenozygomatica (71.5%), followed by the sutura zygomaticomaxillaris (65.8%), sutura temporozygomatica (41.8%), sutura frontomaxillaris (44.5%), and sutura sphenofrontalis (31%). Poor visibility was found for the sutura frontolacrimalis (16.8%) and sutura frontoethmoidalis (1.3%). The sutura ethmoidomaxillaris, sutura lacrimomaxillaris, and sutura ethmoidolacrimalis were not visible. Although the sutures of the superior, lateral, and inferior orbit are well visible, those of the medial orbit are poorly visible on CT scans.

  19. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations*

    Science.gov (United States)

    de Mello Júnior, Carlos Fernando; Araujo Neto, Severino Aires; de Carvalho Junior, Arlindo Monteiro; Rebouças, Rafael Batista; Negromonte, Gustavo Ramalho Pessoa; de Oliveira, Carollyne Dantas

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. PMID:27403020

  20. Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Mário L. R. Monteiro

    2008-01-01

    Full Text Available OBJECTIVES: The objective of this study was to evaluate the ability of a muscular index (Barrett's Index, calculated with multidetector computed tomography, to detect dysthyroid optic neuropathy in patients with Graves' orbitopathy. METHODS: Thirty-six patients with Graves' orbitopathy were prospectively studied and submitted to neuro-ophthalmic evaluation and multidetector computed tomography scans of the orbits. Orbits were divided into two groups: those with and without dysthyroid optic neuropathy. Barrett's index was calculated as the percentage of the orbit occupied by muscles. Sensitivity and specificity were determined for several index values. RESULTS: Sixty-four orbits (19 with and 45 without dysthyroid optic neuropathy met the inclusion criteria for the study. The mean Barrett's index values (± SD were 64.47% ± 6.06% and 49.44% ± 10.94%in the groups with and without dysthyroid optic neuropathy, respectively (p60% should be carefully examined and followed for the development of dysthyroid optic neuropathy.

  1. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Energy Technology Data Exchange (ETDEWEB)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil); Reboucas, Rafael Batista, E-mail: severinoaires@hotmail.com [Faculdade de Ciencias Medicas da Paraiba, Joao Pessoa, PB (Brazil)

    2016-05-15

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  2. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Directory of Open Access Journals (Sweden)

    Carlos Fernando de Mello Júnior

    2016-06-01

    Full Text Available Abstract Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  3. The clinical outcome of occult pulmonary contusion on multidetector-row computed tomography in blunt trauma patients.

    NARCIS (Netherlands)

    Deunk, J.; Poels, T.C.; Brink, M.; Dekker, H.M.; Kool, D.R.; Blickman, J.G.; Vugt, A.B. van; Edwards, M.J.R.

    2010-01-01

    BACKGROUND: Multidetector-row computed tomography (MDCT) is a more sensitive modality as compared with conventional radiography (CR) in detecting pulmonary injuries. MDCT often detects pulmonary contusion that is not visualized by CR, defined as occult pulmonary contusion (OPC). The aim of this stud

  4. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.

  5. Anomalies of abdominal organs in polysplenia syndrome: Multidetector computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Won; Lee, Yong Seok; Jung, Jin Hee [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University School of Medicine, Goyang (Korea, Republic of)

    2016-02-15

    Polysplenia syndrome is a rare situs ambiguous anomaly associated with multiple spleens and anomalies of abdominal organs. Because most of the minor anomalies do not cause clinical symptoms, polysplenia syndrome is detected incidentally in the adults. Anomalies of abdominal organs may include multiple spleens of variable size or right-sided spleen, large midline or left-sided liver, midline gallbladder, biliary tract anomalies, short pancreas, right-sided stomach, intestinal malrotation, inferior vena cava interruption with azygos or hemiazygos continuation, and a preduodenal portal vein. As the multidetector computed tomography is increasingly used, situs anomalies will likely to be found with greater frequency in the adults. Therefore, radiologists should become familiar with these rare and peculiar anomalies of abdominal organs in polysplenia syndrome.

  6. Nutcracker or left renal vein compression phenomenon: multidetector computed tomography findings and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Cuellar i Calabria, Hug; Quiroga Gomez, Sergi; Sebastia Cerqueda, Carmen; Boye de la Presa, Rosa; Miranda, Americo; Alvarez-Castells, Agusti [Hospitals Universitaris Vall D' Hebron, Institut de Diagnostic Per La Imatge, Servei De Radiodiagnostic, Barcelona (Spain)

    2005-08-01

    The use of multidetector computed tomography (MDCT) in routine abdominal explorations has increased the detection of the nutcracker phenomenon, defined as left renal vein (LRV) compression by adjacent anatomic structures. The embryology and anatomy of the nutcracker phenomenon are relevant as a background for the nutcracker syndrome, a rare cause of hematuria as well as other symptoms. MDCT examples of collateral renal vein circulation (gonadal, ureteric, azygous, lumbar, capsular) and aortomesenteric (anterior) and retroaortic (posterior) nutcracker phenomena in patients with no urologic complaint are shown as well as studies performed on patients with gross hematuria of uncertain origin. Incidental observation of collateral veins draining the LRV in abdominal MDCT explorations of asymptomatic patients may be a sign of a compensating nutcracker phenomenon. Imbalance between LRV compression and development of collateral circulation may lead to symptomatic nutcracker syndrome. (orig.)

  7. Multi-detector Computed Tomography Angiography of the Hepatic Artery in Liver Transplant Recipients

    Energy Technology Data Exchange (ETDEWEB)

    Boraschi, P.; Donati, F.; Cossu, M.C.; Gigoni, R.; Vignali, C.; Filipponi, F.; Bartolozzi, C.; Falaschi, F. [Pisa Univ. Hospital (Italy). 2nd Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. MATERIAL AND METHODS: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. RESULTS: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. CONCLUSION: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.

  8. Comparison of in vivo cone-beam and multidetector computed tomographic scans by three-dimensional merging software.

    Science.gov (United States)

    Rostetter, Claudio; Metzler, Philipp; Schenkel, Jan S; Seifert, Burkhardt; Luebbers, Heinz-Theo

    2015-12-01

    In dentomaxillofacial radiology, cone-beam computed tomography (CT) is used to give fast and high-resolution 3-dimensional images of bone with a low dose of radiation. However, its use for quantitative measurement of bone density based on absolute values (Hounsfield units, HU) as in multidetector CT is still controversial. We know of no in vivo study of 3-dimensional merging software that will reliably match identical bone areas of cone-beam and multidetector CT datasets. We studied 19 multidetector, and 19 cone-beam, CT scans of the skull. The two datasets were fused, corresponding points were identified for measurement, and we compared mean density. We used linear regression to analyse the relation between the two different scanning methods, and studied a total of 4180 measurements. The mean time interval between scans was 5.2 (4.7) months. Mean R(2) over all measurements was 0.63 (range 0.22 - 0.79) with a mean internal consistency (Cronbach's α) of 0.86 (range 0.61 - 0.93). The strongest linearity, seen at the left mastoid, was R(2)=0.79 with high internal consistency (Cronbach's α 0.89), and the weakest was at the left zygomatic bone with R(2)=0.22 and Cronbach's α=0.61. Measurements of bone density based on cone-beam and multidetector CT scans generated in vivo showed high and reproducible internal consistency but poor linearity.

  9. Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Dikkers, R. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: r.dikkers@rad.umcg.nl; Greuter, M.J.W. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: m.j.w.greuter@rad.umcg.nl; Kristanto, W. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: w.kristanto@rad.umcg.nl; Ooijen, P.M.A. van [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: p.m.a.van.ooyen@rad.umcg.nl; Sijens, P.E. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: p.e.sijens@rad.umcg.nl; Willems, T.P. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: t.p.willems@rad.umcg.nl; Oudkerk, M. [Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30001, 9700 RB Groningen (Netherlands)], E-mail: m.oudkerk@rad.umcg.nl

    2009-04-15

    Purpose: To assess the influence of temporal resolution on image quality of computed tomographic (CT) coronary angiography by comparing 64-row Dual Source CT (DSCT) and Single Source CT (SSCT) at different heart rates. Methods: An anthropomorphic moving heart phantom was scanned at rest, and at 50 beats per minute (bpm) up to 110 bpm, with intervals of 10 bpm. 3D volume rendered images and curved multi-planar reconstructions (MPRs) were acquired and image quality of the coronary arteries was rated on a 5-points scale (1 = poor image quality with many artefacts, 5 = excellent image quality) for each heart rate and each scanner by 3 observers. Paired sample t-test and Wilcoxon Signed Ranks test were used to assess clinically relevant differences between both modalities. Results: The mean image quality scores at 70, 100 and 110 bpm were significantly higher for DSCT compared to SSCT. The overall mean image quality scores for DSCT (4.2 {+-} 0.6) and SSCT (3.0 {+-} 1.1) also differed significantly (p < 0.001). Conclusion: These initial results show a clinically relevant overall higher image quality for DSCT compared to SSCT, especially at heart rates of 70, 100 and 110 bpm. With its comparatively high image quality and low radiation dose, DSCT appears to be the method of choice in CT coronary angiography at heart rates above 70 bpm.

  10. Comparison of the Diagnostic Image Quality of the Canine Maxillary Dentoalveolar Structures Obtained by Cone Beam Computed Tomography and 64-Multidetector Row Computed Tomography.

    Science.gov (United States)

    Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias

    2015-01-01

    The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.

  11. Diagnostic accuracy of 64 slice multidetector coronary computed tomographic angiography in left ventricular systolic dysfunction

    Directory of Open Access Journals (Sweden)

    Danny Lee

    2015-09-01

    Conclusion: Sixty-four slice multidetector CCTA is a very sensitive and fairly specific noninvasive diagnostic procedure for detecting coronary stenosis in patients with chest pain regardless of LV systolic function at presentation.

  12. Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fischbach, Roman; Juergens, Kai U.; Ozgun, Murat; Maintz, David; Seifarth, Harald; Heindel, Walter [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Grude, Matthias; Wichter, Thomas [University of Muenster, Department of Cardiology and Angiology, Muenster (Germany)

    2007-04-15

    This study compares quantitative and qualitative information on global and regional left ventricular (LV) function obtained with multidetector-row computed tomography (MDCT) with that obtained with magnetic resonance imaging (MRI) in patients with a high prevalence of LV wall motion abnormalities. Thirty patients (19 male, 63.7{+-}15.1 years) with myocardial infarction (n=12), coronary artery disease (n=9), arrhythmogenic right ventricular cardiomyopathy (n=6), and dilation cardiomyopathy (n=3) were included. Segmental LV wall motion (LV-WM) was assessed using a 4-point scale. Wall thickness measurements were calculated in diastolic and systolic short axis images. Two hundred and fifty-two out of 266 (94.7%) normal and 189 out of 214 (88.3%) segments with decreased wall motion were correctly identified by MDCT, yielding a sensitivity of 88% and specificity of 95% for identification of wall motion abnormalities. LV-WM scores were identical in 86.7% of 480 segments ({kappa}=0.809). MDCT had a tendency to underestimate the degree of wall motion impairment. Interobserver agreement was lower in MDCT (66.5%) than in MRI (89.1%; p<0.01). Normokinetic segments are reliably identified with MDCT. Sensitivity for detection and accurate classification of LV wall motion abnormalities need to be improved. Better temporal resolution of the CT system seems to be the most important factor for enhancing MDCT performance. (orig.)

  13. Influence of statin treatment on coronary atherosclerosis visualised using multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Hans [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Klinikum Brandenburg, Department of Cardiology, Angiology, and Pulmonology, Brandenburg an der Havel (Germany); Frieler, Katja [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Potsdam Institut fuer Klimaforschung, Potsdam (Germany); Schlattmann, Peter [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Medical Statistics, Berlin (Germany); Hamm, Bernd [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Dewey, Marc [Charite, Medical School, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology, Berlin (Germany); Charite - Universitaetsmedizin Berlin, Freie Universitaet Berlin and Humboldt-Universitaet zu Berlin, Department of Radiology (Germany)

    2010-12-15

    Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiography in a retrospective longitudinal study. MDCT was performed by using a voxel size of 0.5 x 0.35 x 0.35 mm{sup 3} at two time points 25 {+-} 3 months apart. Non-calcified, calcified and mixed coronary plaque components were analysed by using volumetric measurement. The influence of statin, low-density lipoprotein (LDL) and risk factors was assessed by using a linear random intercept model for plaque growth. The volumes of non-calcified, calcified and mixed coronary plaques significantly (P < 0.001) increased from baseline (medians/interquartile ranges = 21/15-39, 7/3-20 and 36/16-69 mm{sup 3}) to follow-up (29/17-44, 13/6-29 and 41/20-75 mm{sup 3}). Statins significantly slowed the growth of non-calcified plaques (statin coefficient {beta} = -0.0036, P = 0.01) but did not significantly affect the growth rate of mixed or calcified plaques. The effect of statin treatment on non-calcified plaques remained significant after adjusting for LDL levels and cardiac risk factors. Quantification using MDCT shows that progression of non-calcified coronary plaques may be slowed by statins. (orig.)

  14. Multidetector computed tomography findings of dense pulmonary emboli in oncologic patients.

    Science.gov (United States)

    Villanueva, Alberto; Díaz, Maria Lourdes; Sánchez, Armando; Castañer, Eva; Bastarrika, Gorka; Broncano, Jordi; del Barrio, Loreto Garcia

    2009-01-01

    Pulmonary embolism is a frequent condition for which multidetector computed tomography (MDCT) plays an important role in its detection. Occasionally, on MDCT studies, dense linear branching opacities may be found within the pulmonary vessels. They represent dense emboli within the pulmonary arteries (DEPA). These may occur in oncologic patients that undergo specific treatments or interventional procedures, such as cement embolus from vertebroplasty, catheter or coil migration after embolization procedures, radioactive seed embolus in patients treated with local brachytherapy for prostate, lung, or liver cancer, and also in chronic pulmonary embolism. Usually DEPA does not have any clinical significance but may be fatal when massive or when in patients with impaired cardiopulmonary function. Being familiar with their radiologic appearance and knowing about the good clinical outcome of these patients will avoid unnecessary imaging testing. In this article, we describe some examples of DEPA. Based on the MDCT imaging findings, these emboli have very few or no side effects on the underlying lung parenchyma. We would like to stress the need for using bone window values for identifying these emboli. We provide examples of dense linear nonvascular images (pulmonary calcification secondary to tuberculosis (TBC) or radiotherapy, calcified mucous plugs, lung sutures, etc) that may mimic DEPA.

  15. Advances of multidetector computed tomography in the characterization and staging of renal cell carcinoma

    Institute of Scientific and Technical Information of China (English)

    Athina; C; Tsili; Maria; I; Argyropoulou

    2015-01-01

    Renal cell carcinoma(RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography(CT) is considered the examination of choice for thedetection and staging of RCC. Multidetector CT(MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and threedimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment.

  16. Multidetector computed tomography analysis of benign and malignant nodules in patients with chronic lymphocytic thyroiditis.

    Science.gov (United States)

    Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying

    2016-07-01

    The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.

  17. Multidetector Computed Tomography Features in Differentiating Exophytic Renal Angiomyolipoma from Retroperitoneal Liposarcoma

    Science.gov (United States)

    Wang, Qiushi; Juan, Yu-Hsiang; Li, Yong; Xie, Jia-Jun; Liu, Hui; Huang, Hongfei; Liu, Zaiyi; Zheng, Junhui; Saboo, Ujwala S.; Saboo, Sachin S.; Liang, Changhong

    2015-01-01

    Abstract This study aims to evaluate the multidetector computed tomography (CT) imaging features in differentiating exophytic renal angiomyolipoma (AML) from retroperitoneal liposarcoma. We retrospectively enrolled 42 patients with confirmed exophytic renal AML (31 patients) or retroperitoneal liposarcoma (11 patients) during 8 years period to assess: renal parenchymal defect at site of tumor contact, supply from branches of renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, hemorrhage, non–fat-containing intratumoral nodules with postcontrast enhancement, calcification, renal sinus enlargement, anterior displacement of kidneys, and other associated AML. Renal parenchymal defect, renal arterial blood supply, tumoral vessel through the renal parenchyma, dilated intratumoral vessels, intratumoral/perirenal hemorrhage, renal sinus enlargement, and associated AML were seen only or mainly in exophytic renal AML (all P value < 0.05); however, non–fat-attenuating enhancing intratumoral nodules, intratumoral calcification, and anterior displacement of the kidney were more common in liposarcoma (all P value < 0.05). AMLs reveal renal parenchymal defect at the site of tumor contact, supply from renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, intratumoral and/or perirenal hemorrhage, renal sinus enlargement, and associated AML. Non–fat-attenuating enhancing intratumoral nodules, intratumoral calcifications, and anterior displacement of kidney were more commonly seen in liposarcoma. PMID:26376398

  18. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Jeong, Yong Yeon [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2015-06-15

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall.

  19. Preoperative Diagnosis of Extraglandular Invasion of Thyroid Papillary Carcinoma: High Resolution Sonography versus Multidetector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yoon Jung; Hong, Hyun Pyo; Kwag, Hyon Joo; Kook, Shin Ho; Yun, Ji Sup; Kim, Dong Hoon [Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2009-03-15

    To compare the diagnostic efficacy of high-resolution sonography (HRS) and multidetector computed tomography (MDCT) in determining the presence of extraglandular invasion of thyroid papillary cancer and to define ultrasound (US) features of perithyroidal invasion that correlate with histopathological findings. We prospectively evaluated extracapsular invasion in 177 thyroid cancer patients using both HRS and MDCT. Receiver operating characteristics (ROC) were assessed with a four-point confidence scale (0 = no extracapsular invasion:1 = possible invasion:2 = probable invasion:3 = definite invasion) by two reviewers for each imaging modality. Sensitivity, specificity, and accuracy were analyzed for each modality, along with interobserver variability. MDCT had a mean area under the ROC curve larger than that of HRS (HRS = 0.733, MDCT = 0.807, p < 0.05). HRS and MDCT were significantly different with regard to diagnostic sensitivity, specificity, and accuracy for extrathyroidal extension (p < 0.05: HRS = 75.7%, 66.1%, and 69.8%, respectively: MDCT = 86.7%,69.7%, and 76%, respectively). Interobserver reliability was greater for MDCT than for HRS (kappa value, 0.861 versus 0.429). The cutoff value used in HRS for estimating the status of perithyroidal invasion was 2. Conclusion: HRS may be useful for preoperative investigation of thyroid papillary carcinoma extension, but it was inferior to MDCT because of lower diagnostic accuracy and lower interobserver reliability

  20. Complications of myocardial infarction on multidetector-row computed tomography of chest

    Energy Technology Data Exchange (ETDEWEB)

    Raj, V.; Karunasaagarar, K. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Rudd, J.H.F. [Division of Cardiovascular Medicine, University of Cambridge, Cambridge (United Kingdom); Screaton, N. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.co [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom)

    2010-11-15

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  1. Underdiagnosis of Vertebral Collapse on Routine Multidetector Computed Tomography Scan of the Abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Obaid, H.; Husamaldin, Z.; Bhatt, R. (Doncaster Royal Infirmary, Doncaster (United Kingdom))

    2008-09-15

    Background: Vertebral fractures are commonly associated with osteoporosis and have significant morbidity and mortality rates. Osteoporotic vertebral fractures are presently considered as a treatable and preventable condition, and early detection is vital for further management. The evaluation of vertebral compression on multidetector computed tomography (MDCT) scans of the abdomen has, to our knowledge, not been reported before. Purpose: To assess the prevalence of vertebral collapse on routine abdominal CT scans, and to evaluate the usefulness of the multiplanar reconstruction (MPR) capability of MDCT scans in accurately identifying vertebral abnormalities such as vertebral collapse, spondylolisthesis, and retrolisthesis. Material and Methods: A retrospective review of 307 MDCT scans of the abdomen was carried out at a university teaching hospital. Identifiable patient information was anonymized for data protection. All images were reviewed on a picture archiving and communications system (PACS) using sagittal MPR and bone window for the assessment of the vertebrae. Data were collected from the Computerized Radiology Information System (CRIS). Results: Vertebral collapse was seen in 42 (13.6%) of the 307 patients undergoing routine MDCT of the abdomen. Multilevel and single-level collapses were seen in 24 and 18 patients, respectively. Spondylolisthesis was identified in 5.5% (n=17), and retrolisthesis was seen in 0.6% (n=2). All patients with vertebral fracture were older than 50 years. Women were more commonly affected than men. Conclusion: A significant number of patients with vertebral collapse were diagnosed using MPR on MDCT routine scans of the abdomen

  2. Multidetector Computed Tomography Imaging of Facial Trauma in Accidental Falls from Heights

    Energy Technology Data Exchange (ETDEWEB)

    Salonen, E.M.; Koivikko, M.P.; Koskinen, S.K. [Helsinki Medical Imaging Center, Dept. of Radiology, Toeoeloe Trauma Center, Helsinki Univ. Hospital, Helsinki (Finland)

    2007-04-15

    Purpose: To assess multidetector computed tomography (MDCT) findings in facial trauma in adults who accidentally fall from heights. Material and Methods: Of the MDCT scans of 2413 cases requested by emergency-room physicians for suspected facial injury, 155 (age 15.3-76.7, mean 42.0 years; 134 male, 21 female) met the criteria of falling from heights. These were reviewed by two researchers by consensus. Results: Of these 155, 118 (104 male, 14 female) had 247 fractures, while 37 had no fracture. The fractures were classified into 13 categories, the zygomatic complex being the region most frequently involved. Mean falling height, known in 132 of 155 cases, was 5.7 m (range 0.4-25) in all, 6.0 m (0.4-25) in those suffering a fracture, and 5.0 m (range 0.4-13) in those without a fracture. Patients with Le Fort II, Le Fort III, or frontal bone fractures had fallen higher and frequently had associated skull base fractures, but with considerable overlap in falling heights. Zygomatic arch and nasal bone fractures rarely occurred solitarily. Conclusion: In a fall-from-height injury, nasal bone and zygomatic arch fractures indicate the presence of more severe fractures. Height cannot solely predict injury probability. Clear sinus sign is a valuable aid in assessing midface trauma in falls from heights. Keywords: CT; face; trauma.

  3. Diagnostic Value of Multidetector Computed Tomography in Radial Head or Neck Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyun Hae; Hwang, Ji Young; Lee, Sun Wha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic value of multidetector computed tomography (MDCT) in radial head or neck fracture, and to evaluate factors that affect MDCT image quality. Sixty-six radial fractures in 65 patients, who underwent both radiography and MDCT, were included. Detection of fracture and classification of types were recorded for each modality. Patients were divided into the good (A) and poor (B) image quality groups, and recorded the factors, such as arm positioning, flexion angle, and cancellous bone density. The detection rate of fracture showed no significant difference between the two modalities. However, classification of the fracture type was significantly accurate by MDCT (p < 0.0001). Eight cases were only detected on MDCT and three cases were only detected on radiography. Fracture type was discordant in 11 cases. MDCT scanning with raising arm (p < 0.0001), with lesser flexion angle (p = 0.004), and higher cancellous bone density (p 0.010) showed better image quality. Radiography is a good primary tool for detecting radial head or neck fracture. However, MDCT can be an additional tool for classifying the fracture type and cases with negative radiographic findings. Arm positioning, flexion angle, and cancellous bone density affect MDCT image quality.

  4. Prevalence of ear disease in dogs undergoing multidetector thin-slice computed tomography of the head.

    Science.gov (United States)

    Foster, Allison; Morandi, Federica; May, Elizabeth

    2015-01-01

    Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported.

  5. Role of multidetector computed tomography (MDCT in patients with ovarian masses

    Directory of Open Access Journals (Sweden)

    Mubarak F, Alam MS

    2011-04-01

    Full Text Available Fatima Mubarak, Muhammad Shahbaz Alam, Waseem Akhtar, Saima Hafeez, Noureen NizamuddinRadiology Department, Aga Khan University Hospital, Karachi, PakistanObjective: To evaluate the diagnostic accuracy of multidetector 64-slice computed tomography (MDCT in the diagnosis and differentiation of benign and malignant ovarian masses using histopathology and surgical findings as the gold standard.Material and methods: This study was conducted in Aga Khan University Hospital, Karachi, Pakistan. Data was reviewed retrospectively from 1 November 2008 to 12 December 2009. One hundred patients found to have ovarian masses on CT scan were included in the study. CT scan was performed in all these patients after administration of oral and IV contrast. Ovarian masses were classified as benign and malignant on scan findings. Imaging findings were compared with histopathologic results and surgical findings. Sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and diagnostic accuracy of MDCT were calculated.Results: MDCT was found to have 97% sensitivity, 91% specificity, and an accuracy of 96% in the differentiation of benign and malignant ovarian masses, while PPV and NPV were 97% and 91%, respectively.Conclusion: MDCT imaging offers a safe, accurate and noninvasive modality to differentiate between benign and malignant ovarian masses.Keywords: ovarian masses, surgery, MDCT

  6. Evaluation of cardiovascular anomalies in patients with asymptomatic turner syndrome using multidetector computed tomography.

    Science.gov (United States)

    Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong

    2013-08-01

    Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.

  7. Pulmonary emphysema in cystic fibrosis detected by densitometry on chest multidetector computed tomography.

    Directory of Open Access Journals (Sweden)

    Mark O Wielpütz

    Full Text Available BACKGROUND: Histopathological studies on lung specimens from patients with cystic fibrosis (CF and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT of the chest for non-invasive characterization and quantification of emphysema in CF. METHODS: Volumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years and 21 non-CF controls (median age 30.4 years; range 4-68 years, and subjected to dedicated software. The lung was segmented, low attenuation volumes below a threshold of -950 Hounsfield units were assigned to emphysema volume (EV, and the emphysema index was computed (EI. Results were correlated with forced expiratory volume in 1 s percent predicted (FEV1%, residual volume (RV, and RV/total lung capacity (RV/TLC. RESULTS: We show that EV was increased in CF (457±530 ml compared to non-CF controls (78±90 ml (P<0.01. EI was also increased in CF (7.7±7.5% compared to the control group (1.2±1.4% (P<0.05. EI correlated inversely with FEV1% (rs=-0.66, and directly with RV (rs=0.69 and RV/TLC (rs=0.47 in patients with CF (P<0.007, but not in non-CF controls. Emphysema in CF was detected from early adolescence (~13 years and increased with age (rs=0.67, P<0.001. CONCLUSIONS: Our results indicate that early onset emphysema detected by densitometry on chest MDCT is a characteristic pathology that contributes to airflow limitation and may serve as a novel endpoint for monitoring lung disease in CF.

  8. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants *

    Science.gov (United States)

    Araujo Neto, Severino Aires; de Mello Júnior, Carlos Fernando; Franca, Henrique Almeida; Duarte, Cláudia Martina Araújo; Borges, Rafael Farias; de Magalhães, Ana Guardiana Ximenes

    2016-01-01

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. PMID:26929461

  9. Multidetector computed tomography angiography of the celiac trunk and hepatic arterial system: normal anatomy and main variants

    Energy Technology Data Exchange (ETDEWEB)

    Araujo-Neto, Severino Aires; Mello-Junior, Carlos Fernando de; Franca, Henrique Almeida; Duarte, Claudia Martina Araujo; Borges, Rafael Farias; Magalhaes, Ana Guardiana Ximenes de, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2016-01-15

    Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications. (author)

  10. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Zhao, Yingru; Snijder, R.A.; van Ooijen, P.M.; de Jong, P.A.; Oudkerk, M.; de Bock, G.H.; Vliegenthart, R.; Greuter, M.J.

    2013-01-01

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 H

  11. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mustonen, A.O.T. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Koskinen, S.K. [Research Inst. of Military Medicine, Helsinki (Finland); Kiuru, M.J. [ORTON Orthopaedic Hospital, Helsinki (Finland)

    2005-12-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately.

  12. Scoliotic Change in Patients Having Undergone a Mastectomy: Analysis Using Multi-Detector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Sang; Kim, Hye Won; Juhng, Seon Kwan; Choi, Si Sung [Dept. of Radiology, Wankwang University School of Medicine, Iksan (Korea, Republic of)

    2011-09-15

    To evaluate the relationship between the degree of scoliotic curvature and postoperative change of the chest wall among patients who underwent a unilateral mastectomy. Subjects were comprised of 56 women who underwent chest CT and a whole spine standing anteroposterior view (WSSAP). Cobb's angle and each side of the chest wall volume, including the breast, were measured with the WSSAP and a 3-D reconstructed multi-detector computed tomography (MDCT) image. A correlation analysis was performed between the scoliotic curvature and chest wall volume asymmetry. Directional correspondence between development of scoliosis and undergoing a mastectomy was analyzed. Furthermore, a survey on patient shoulder function was performed using a questionnaire and a correlation was performed between the results of the survey and the scoliotic curvature and chest wall volume asymmetry. The findings indicate that Cobb's angles were 4.4 degree {+-} 2.7 (Mean {+-} SD, range from 0.6 to 11.4). Differences in chest wall volume were 474.64 {+-} 276.36 cm{sup 3} (Mean {+-} SD, range from 78 to 1379). No statistical significance was noted between the degree of scoliotic curvature and chest wall volume asymmetry (p > 0.05). A cross-tabulation analysis of the direction between the scoliotic curvature and mastectomy was found to be statistically significant (p < 0.001). Also, there was a significant correlation between shoulder function assessment score and the degree of scoliotic curvature (p = 0.003), while no significant correlation between shoulder function assessment score and chest wall volume asymmetry (p 0.091) could be found. Scoliotic change had a tendency to be on the opposite side of the mastectomy and had no statistically significant relationship with the volume asymmetry. Thus, 3-D reconstructed MDCT images are helpful in differentiating selective volume differences.

  13. The role of multidetector computed tomography in evaluation of small bowel obstructions

    Directory of Open Access Journals (Sweden)

    Mehmet Fatih İnci

    2013-03-01

    Full Text Available Objective: The purpose of the study was to evaluate therole and additional diagnostic contribution of multi-detectorcomputed tomography (MDCT in patients with acuteabdominal pain caused by small bowel obstruction.Materials and methods: A total of 48 patients who admittedto our hospital with acute abdominal pain and underwentMDCT on suspicion of intestinal obstruction and hadabdominal surgery between January 2012 and October2012 were included to our study. MDCT images were interpretedby two experienced radiologist retrospectively.All clinical data and surgery notes also were evaluated.Patients had surgery due to penetrating or blunt abdominalinjury were excluded.Results: Of these 48 patients, 26 (54.1% were male and22 (45.9% were female. Patients’ ages ranged 25 to 71and mean age was 52±5.4 years. The causes of intestinalobstruction of patients were adhesions for 12 (46.1% patients,tumors for 7 (26.9% patients, external hernias for5 (19.2% patients, internal hernia for 1 (3.9% patient andintussusception for 1 (3.9% patient. A total concordancebetween the MDCT findings and definitive diagnosis wasfound in 26 of 23 cases and the sensitivity and specifityof MDCT in the diagnosis of small bowel obstruction werefound to be 88.5% and 90%, respectively.Conclusion: MDCT is a fast, effective and reliable imagingmethod for preoperative diagnosing small bowel obstructioncauses acute abdominal pain with the advantagesof MDCT such as multi-planar and three-dimensionalreformatted imaging.Key words: Acute abdominal pain, multi-detector computed tomography, small bowel obstruction

  14. Assessment of myocardial viability using multidetector computed tomography in patients with reperfused acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Choi, B.J. [Department of Cardiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Kang, D.K., E-mail: kdklsm@ajou.ac.kr [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Sun, J.S. [Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2012-08-15

    Aim: To assess the prognostic value of 64-section multidetector computed tomography (MDCT) to predict follow-up myocardial dysfunction and functional recovery after reperfusion therapy in patients with acute myocardial infarction (MI) as defined by echocardiography. Materials and methods: After reperfusion therapy for acute MI, 71 patients underwent two-phase contrast-enhanced MDCT and follow-up echocardiography. MDCT findings were compared with echocardiographic findings using kappa statistics. The areas under the receiver operating characteristic curves (AUCs) and the odds ratios (ORs) of early perfusion defects (EPD), delayed enhancement (DE), and residual perfusion defects (RPD) for predicting follow-up myocardial dysfunction and functional recovery were calculated on a segmental basis. Results: The presence of transmural EPD (EPD{sub TM}) or RPD showed good agreement (k = 0.611 and 0.658, respectively) with follow-up myocardial dysfunction, while subendocardial EPD (EPD{sub sub}) or subendocardial DE (DE{sub sub}) showed fair agreement with follow-up myocardial dysfunction (k = 0.235 and 0.234, respectively). The AUC of RPD (0.796) was superior (p < 0.001 and 0.031, respectively) to those of EPD{sub TM} (0.761) and DE{sub TM} (0.771). The presence of EPD{sub TM}, DE{sub TM}, and RPD were significant, independent positive predictors of follow-up myocardial dysfunction (OR = 6.4, 1.9, and 9.8, respectively). EPD{sub TM} was a significant, independent negative predictor of myocardial functional recovery (OR = 0.13). Conclusion: Abnormal myocardial attenuation on two-phase MDCT after reperfusion therapy may provide promising information regarding myocardial viability in patients with acute MI.

  15. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lessick, Jonathan, E-mail: j_lessick@rambam.health.gov.il [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Abadi, Sobhi [Medical Imaging Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Agmon, Yoram [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Keidar, Zohar [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Carasso, Shemi; Aronson, Doron [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Ghersin, Eduard [Department of Diagnostic Radiology, University of Miami, Miller School of Medicine, Miami, FL (United States); Rispler, Shmuel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Sebbag, Anat [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Israel, Ora [Nuclear Medicine Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel); Hammerman, Haim; Roguin, Ariel [Cardiology Department, Rambam Health Care Campus, Haaliya Street, Haifa (Israel); Technion-IIT, Haaliya Street, Haifa (Israel)

    2012-10-15

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition.

  16. Multidetector computed tomography features of pancreatic metastases from leiomyosarcoma: Experience at a tertiary cancer center

    Institute of Scientific and Technical Information of China (English)

    Chong Hyun Suh; Abhishek Keraliya; Atul B Shinagare; Kyung Won Kim; Nikhil H Ramaiya; Sree Harsha Tirumani

    2016-01-01

    AIM: To describe the multidetector computed tomography features of pancreatic metastasis from leiomyosarcoma(LMS).METHODS: Between January 1995 and December 2012, 13 consecutive patients(11 women, 2 men; mean age of 57 years; range, 38-78 years) with pancreatic metastases from LMS were included in our study. Imaging features including location, number, largest dimension, tumor attenuation and enhancement characteristics, presence of necrosis, pancreatic ductal dilatation, common bile duct(CBD) dilatation, presence of pancreatitis, and atrophy were documented.RESULTS: The most common site of origin of the pancreatic metastases from LMS was uterus(38.5%), followed by retroperitoneum(30.8%) and extremity(23.1%). None of the patients in our study had pancreas as the first site of metastasis. All patients developed pancreatic metastases at a median interval of 24 mo. Pancreatic metastases from LMS were solitary in 8/13 patients and multiple in 5/13 patients, had no predilection for any part of the pancreas, were hypovascular on arterial phase in 10/13 patients and associated with pancreatic duct dilatation in 3/13 patients. None had CBD dilatation. None of the pancreatic metastases in LMS cohort caused pancreatitis, and atrophy. Median duration of follow-up was 19 mo for LMS cohort during which two patients underwent resection of metastasis(median survival 45 mo) while the remaining underwent systemic therapy(median survival 13 mo).CONCLUSION: Pancreatic metastases from LMS are often solitary and hypovascular masses and less commonly associated with pancreatic ductal dilatation, CBD dilatation, pancreatitis or pancreatic atrophy. Surgical resection of solitary LMS pancreatic metastasis can be considered due to the long survival of these patients.

  17. Diagnostic value of multidetector computed tomography for renal sinus fat invasion in renal cell carcinoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cherry, E-mail: cherrykim0505@gmail.com; Choi, Hyuck Jae, E-mail: choihj@amc.seoul.kr; Cho, Kyoung-Sik, E-mail: kscho@amc.seoul.kr

    2014-06-15

    Objective: Although renal sinus fat invasion has prognostic significance in patients with renal cell carcinomas (RCCs), there are no previous studies about the value of multidetector computed tomography (MDCT) about this issue in the current literature. Materials and methods: A total of 863 consecutive patients (renal sinus fat invasion in 110 patients (12.7%)) from single institutions with surgically-confirmed renal cell carcinoma who underwent MDCT between 2010 and 2012 were included in this study. The area under the curves (AUCs) of the receiver operating characteristic (ROC) analysis was used to compare diagnostic performance. Reference standard was pathologic examination. Weighted κ statistics were used to measure the level of interobserver agreement. Multivariate logistic regression model was used to find the predictors for renal sinus fat invasion. Image analysis was first performed with axial-only CT images. A second analysis was then performed with both axial and coronal CT images. A qualitative analysis was then conducted by two reviewers who reached consensus regarding tumor size, decreased perfusion, tumor margin, vessel displacement, and lymph node metastasis. The reference standard was pathologic evaluation. Results: The AUCs of the ROC analysis were 0.881 and 0.922 for axial-only images and 0.889 and 0.902 for combined images in both readers. The AUC of tumor size was 0.884, a similar value to that of the reviewers. In multivariate analysis, tumor size, a linear-nodular or nodular type of fat infiltration, and an irregular tumor margin were independent predicting factors for perinephric fat invasion. Conclusion: MDCT shows relatively high diagnostic performance in detecting perinephric fat invasion of RCC but suffers from a relatively low PPV related to low prevalence of renal sinus fat invasion. Applying tumor size alone we could get similar diagnostic performance to those of radiologists. Tumor size, fat infiltration with a nodular appearance, and

  18. Multidetector computed tomography arthrography of the knee: Diagnostic accuracy and indications

    Energy Technology Data Exchange (ETDEWEB)

    De Filippo, Massimo [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy)], E-mail: massimo.defilippo@unipr.it; Bertellini, Annalisa [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Pogliacomi, Francesco [Department of Surgery, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Sverzellati, Nicola [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Corradi, Domenico [Department of Anatomy, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy); Garlaschi, Giacomo [Department of Radiology, University of Genoa, Genoa Hospital, Via Balbi, 5-16126 Genova (Italy); Zompatori, Maurizio [Department of Clinical Sciences, Section of Radiological Sciences, University of Parma, Parma Hospital, Via Gramsci 14, 43100 Parma (Italy)

    2009-05-15

    Purpose: To evaluate the diagnostic accuracy and indications of arthrography with multidetector computed tomography (arthro-MDCT) of the knee, in patients with absolute or relative contraindications to MRI and in patients with periarticular metal implants using diagnostic arthroscopy as the gold standard. Materials and methods: After intra-articular injection of iodixanol and volumetric acquisition, 68 knees in patients of both sexes (30 females, 38 males, age range 32-60 years) were examined with a 16-detector-row CT scanner. The patients had arthralgia but no radiologically detected fractures. They could not be studied by MRI either because of absolute contraindications (subcutaneous electronic implants), surgical metal implants or claustrophobia. In 37 of 68 patients who had had previous knee surgery, the arthro-CT examination was preceded by an MRI on the same day. All examinations were interpreted by two experienced musculoskeletal radiologists. The findings were compared with arthroscopic findings carried out within 28 days of the CT study. Results: In non-operated patients the comparison between arthro-MDCT and arthroscopy showed sensitivity and specificity ranging between 86% and 100%. In the 37 operated knees, arthro-MDCT had an accuracy of 95% compared with 53% of the MRI. Inter-observer agreement was almost perfect (K = 0.97) in the evaluation of all types lesions, both on MDCT and MRI. When arthro-MDCT was compared with MRI in post-operative patients by a McNemar test, a significant difference (p < 0.05) was found between these two techniques. Conclusions: Arthro-MDCT of the knee is a safe technique that provides accurate diagnosis in identifying chondral, fibrocartilaginous and intra-articular ligamentous lesions, in patients that cannot be evaluated by MRI, and in patients after surgical.

  19. Evaluation of multidetector computed tomography urography and ultrasonography for diagnosing bladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Knox, M.K. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Cowan, N.C. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom); Department of Radiology, Churchill Hospital, Oxford OX3 7LJ (United Kingdom)], E-mail: nigel.cowan@nds.ox.ac.uk; Rivers-Bowerman, M.D.; Turney, B.W. [Nuffield Department of Surgery, University of Oxford, Oxford (United Kingdom)

    2008-12-15

    Aim: To evaluate and compare the diagnostic accuracy of multidetector computed tomography urography (CTU) and ultrasonography (US) for diagnosing bladder cancer. Materials and methods: A consecutive series of 143 patients over 40-years of age, presenting with macroscopic haematuria and without urinary tract infection underwent same-day CTU, US, and flexible cystoscopy. CTU and US were independently rated on a five-point scale for the presence of bladder cancer without knowledge of the reference standard of flexible or rigid cystoscopy and/or biopsy results. Diagnostic accuracy was assessed by receiver operating characteristic (ROC) analysis and likelihood ratios. Results: For CTU, a rating of 5 (definitely tumour) was highly specific for bladder cancer (96.5%, 95%CI: 91.3-99%), effectively confirming diagnosis (positive likelihood ratio 25.6, 95%CI: 9.7-67.4). For US, specificity was also high (94.7%, 95%CI: 88.9-98%) with a positive likelihood ratio of 13.1 (95%CI: 5.8-29.6). Sensitivity at this rating was substantially higher for CTU (89.7%, 95%CI: 72.7-97.8%) than US (69%, 95%CI: 49.2-84.7%). Standardized partial area (A{sub z}) under the ROC curve between 95-100% specificity, representing the average sensitivity in this range, was significantly greater (0.88 versus 0.61, p < 0.05) for CTU than US. Conclusion: The specificities of CTU and US for the diagnosis of bladder cancer were similar, but CTU was more sensitive. Although the sensitivity of CTU was not high enough to replace flexible cystoscopy in the diagnostic pathway, the high specificity enables direct referral to rigid cystoscopy, bypassing flexible cystoscopy and expediting diagnosis and treatment in those patients testing positive.

  20. Imaging features of solid pseudopapillary tumor of the pancreas on multi-detector row computed tomography

    Institute of Scientific and Technical Information of China (English)

    Deng-Bin Wang; Qing-Bing Wang; Wei-Min Chai; Ke-Min Chen; Xia-Xing Deng

    2009-01-01

    AIM:To retrospectively analyze the imaging features of solid-pseudopapillary tumors (SPTs) of the pancreas on multi-detector row computed tomography (MDCT) and define the imaging findings suggestive of malignant potential.METHODS: A total of 24 consecutive cases with surgically and pathologically confirmed SPTs of the pancreas underwent preoperative abdominal MDCT studies in our hospital. All axial CT images, CT angiographic images, and coronally and sagittally reformed images were obtained. The images were retrospectively reviewed at interactive picture archiving and communication system workstations. RESULTS: Of the 24 cases of SPTs, 11 cases (45.8%) occurred in the pancreatic head and seven (29.1%) in the tail. Eighteen were pathologically diagnosed as benign and six as malignant. MDCT diagnosis of SPTs was well correlated with the surgical and pathological results (Kappa = 0.6, P < 0.05). The size of SPTs ranged from 3 to 15 cm (mean, 5.8 cm). When the size of the tumor was greater than 6 cm (including 6cm), the possibilities of vascular (8 vs 1) and capsular invasion (9 vs 0) increased significantly ( P < 0.05). Two pathologically benign cases with vascular invasion and disrupted capsule on MDCT presented with local recurrence and hepatic metastases during follow-up about 1 year after the resection of the primary tumors.CONCLUSION: Vascular and capsular invasion with superimposed spread into the adjacent pancreatic parenchyma and nearby structures in SPTs of the pancreas can be accurately revealed by MDCTpreoperatively. These imaging findings are predictive of the malignant potential associated with the aggressive behavior of the tumor, even in the pathologically benign cases.

  1. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Chou [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tsai, Shih-Hung [Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Chang, Wei-Kuo [Division of Gasteroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Liu, Chang-Hsien [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tung, Ho-Jui [Department of Healthcare Administration, Asia University, Taichung, Taiwan (China); Hsieh, Chung-Bao [Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Huang, Guo-Shu; Hsu, Hsian-He [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Yu, Chih-Yung, E-mail: chougo2002@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China)

    2011-11-15

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  2. Multidetector computed tomography mesentericography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Heiss, P.; Hamer, O.W.; Mueller-Wille, R.; Rennert, J.; Feuerbach, S.; Zorger, N. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik; Wrede, C.E. [Helios-Klinikum Berlin-Buch (Germany). Interdisziplinaeres Notfallzentrum mit Rettungsstelle; Siebig, S.; Schoelmerich, J. [Regensburg Univ. (Germany). Medizinische Klinik und Poliklinik I

    2011-01-15

    Purpose: To evaluate the diagnostic yield of 16-row multidetector computed tomography (CT) mesentericography in patients with obscure gastrointestinal bleeding. Materials and Methods: The radiological information system database was used to retrospectively identify all patients in whom CT mesentericography (CTM) was performed for the diagnosis of obscure gastrointestinal bleeding between July 2002 and September 2006. A subsequent prospective study was conducted between October 2006 and September 2009 to evaluate CTM in patients with major obscure gastrointestinal bleeding. The retrospectively identified patients (six patients) as well as the prospectively evaluated patients (seven patients) constitute the study population. Following mesenteric DSA the catheter was left in the superior mesenteric artery, the patient was transferred to the CT suite and CTM was carried out by scanning the abdomen after contrast material injection via the catheter. Active bleeding was suspected if a focal area of high attenuation consistent with contrast material extravasation was found within the bowel lumen. Results: CTM detected the site of active bleeding in three of 13 patients (23 %). In the subpopulation of patients who were prospectively evaluated, CT mesentericography identified the site of active bleeding in one of seven patients (14 %). Depiction of active bleeding by CTM prompted surgical intervention in each case and surgery confirmed the findings of CT mesentericography. Conclusion: Due to the relatively low rate of positive findings and inherent drawbacks, we feel that CTM cannot be recommended in general. However, in selected patients who are continuously bleeding at a low rate and in whom iv-CT was negative, CT mesentericography might be helpful. (orig.)

  3. Differentiation between tuberculosis and leukemia in abdominal and pelvic lymph nodes: evaluation with contrast-enhanced multidetector computed tomography

    Directory of Open Access Journals (Sweden)

    Ge Zhang

    2015-03-01

    Full Text Available PURPOSE: To compare the characteristics of tubercular vs. leukemic involvement of abdominopelvic lymph nodes using multidetector computed tomography (CT. MATERIALS AND METHODS: We retrospectively reviewed multidetector computed tomography features including lymph node size, shape, enhancement patterns, and anatomical distribution, in 106 consecutive patients with newly diagnosed, untreated tuberculosis (55 patients; 52% or leukemia (51 patients; 48%. In patients with leukemia, 32 (62.7% had chronic lymphocytic leukemia, and 19 (37.3% had acute leukemias; of these, 10 (19.6% had acute myeloid leukemia, and 9 (17.6% had acute lymphocytic leukemia. RESULTS: The lower para-aortic (30.9% for tuberculosis, 63.2% for acute leukemias and 87.5% for chronic lymphocytic leukemia and inguinal (9.1% for tuberculosis, 57.9% for acute leukemias and 53.1% for chronic lymphocytic leukemia lymph nodes were involved more frequently in the three types of leukemia than in tuberculosis (both with p <0.017. Tuberculosis showed peripheral enhancement, frequently with a multilocular appearance, in 43 (78.2% patients, whereas patients with leukemia (78.9% for acute myeloid leukemia and acute lymphocytic leukemia, 87.5% for chronic lymphocytic leukemia demonstrated predominantly homogeneous enhancement (both with p <0.017. For the diagnosis of tuberculosis, the analysis showed that a peripheral enhancement pattern had a sensitivity of 78.2%, a specificity of 100%, and an accuracy of 88.7%. For the diagnosis of leukemia, the analysis showed that a homogeneous enhancement pattern was associated with a sensitivity of 84.3%, a specificity of 94.5%, and an accuracy of 89.6%. CONCLUSION: Our findings indicate that the anatomical distribution and enhancement patterns of lymphadenopathy seen on multidetector computed tomography are useful for differentiating between untreated tuberculosis and leukemia of the abdominopelvic lymph nodes.

  4. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Habets, Jesse; van den Brink, Renee B. A.; Uijlings, Ruben; Spijkerboer, Anje M.; Mali, Willem P. Th. M.; Chamuleau, Steven A. J.; Budde, Ricardo P. J.

    2012-01-01

    Objectives Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. Methods ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of p

  5. Using the 320-Multidetector Computed Tomography scanner for four-dimensional functional assessment of the elbow joint.

    Science.gov (United States)

    Goh, Yin Peng; Lau, Kenneth K

    2012-02-01

    As described in this case report, the use of the 320-Multidetector Computed Tomography scanner (Aquilion One, Toshiba Medical Systems, Japan) to produce continuous 3-dimensional images in real time, over a distance of 16 cm in the z-axis, proved to aid in the diagnosis of a patient's restrictive elbow joint. This state-of-the-art scanner allows fast and noninvasive dynamic-kinematic functional evaluation of the elbow joint in vivo. It will also be applicable to kinematic studies of other joints.

  6. A case of fatal sigmoid volvulus visualized on postmortem radiography: The importance of image optimization with multidetector computed tomography.

    Science.gov (United States)

    Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Ishizuka, Yuya; Ikeda, Tomoya; Saito, Haruo; Funayama, Masato

    2016-03-01

    This report describes the case of a man who developed fatal sigmoid volvulus that was identified on postmortem radiography before forensic autopsy. Postmortem radiography is useful for visualizing the body prior to autopsy. We discuss postmortem multidetector computed tomography that was tailored for optimum image quality to allow reconstruction of the fatal findings in multiple axes and in three dimensions, helping to pinpoint the anatomical sites of interest. This involves techniques such as manipulation of the scanning beam pitch and overlapping CT section acquisition. These techniques are best performed by personnel with CT technology training.

  7. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy); Scaglione, Mariano [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy)], E-mail: mscaglione@tiscali.it

    2008-03-15

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections.

  8. Normal values for renal parenchymal volume and kidney length as measured by non-enhanced multidetector spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei; Wu, Xiao Hou (Dept. of Urology, The First Affiliated Hospital of Chongqing Medical Univ., Chongqing (China)), email: wuxiaohou@yahoo.com; Yang, Mei (Inst. of Neuroscience, Chongqing Medical Univ., Chongqing (China)); Luo, Chun Li (Dept. of Laboratory Medicine, Chongqing Medical Univ., Chongqing (China)); Pang, Hua (Dept. of Radiology, The First Affiliated Hospital of Chongqing Medical Univ., Chongqing (China))

    2011-07-15

    Background: Renal parenchymal volume (RPV) is considered an important index for clinical decisions. However, normal values have not been established, which hinders the clinical application of RPV. Purpose: To test the accuracy and reproducibility of RPV and to investigate the normal values of RPV and kidney length as measured by non-enhanced multidetector computed tomography (CT). Material and Methods: An animal model study was performed to test the accuracy and repeatability of RPV measured by CT. RPV of porcine kidneys was measured by water displacement (actual values) and non-enhanced multidetector CT. Individual RPV and kidney length were measured by non-enhanced CT in patients with no clinical history of renal disease (n 722). Patient height, age, weight, body surface area (BSA), and body mass index (BMI) were assessed before each patient's CT examination was performed. Results: RPV obtained by the CT method was within 2% of the RPV determined by the water displacement method. The normal values of RPV (M +- 1.96 standard deviation [SD]) were 145.72 +- 54.37 mL for men and 132.46 +- 41.94 mL for women. The normal values of kidney length (M +- 1.96 SD) were 10.27 +- 1.98 cm for men and 9.93 +- 1.58 cm for women. RPV did not significantly correlate with BSA or weight in women, but correlated significantly with height and age in both men and women. Of the assessed factors age, weight, height, BSA, and BMI, age, and height were the independent factors that best reflected RPV, in both men and women. Conclusion: The present animal study results showed that non-enhanced multidetector CT findings accurately reflect the RPV. The subsequent study performed in humans showed that the RPV of the presently sampled Chinese population was lower than the commonly quoted reference values obtained from Western populations

  9. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  10. Retroaortic Left Renal Vein: Multidetector Computed Tomography Angiography Findings and Its Clinical Importance

    Energy Technology Data Exchange (ETDEWEB)

    Karaman, B.; Koplay, M.; Oezturk, E.; Basekim, C.C.; Ogul, H.; Mutlu, H.; Kizilkaya, E.; Kantarci, M. [Dept. of Radiology, Sivas Military Hospital, Sivas (Turkey)

    2007-04-15

    Purpose: To evaluate the appearance, type, frequency, and clinical importance of retroaortic left renal vein (RLRV) in patients examined with multidetector computed tomography (MDCT) angiography. Material and Methods: A total of 1856 patients who underwent CT with urological symptoms (hematuria, flank and abdominal pain, left gonadal vein varicocele) (n = 889) or with symptoms other than urological ones (n = 967) were prospectively evaluated for the presence of RLRV. CT was performed with 110 ml of iodinated contrast material through the antecubital vein at a rate of 3.5 ml/s. Late arterial and early venous phase volumetric data sets were acquired at 30 and 65 s, respectively, from the start of the intravenous injection of contrast medium. In addition to axial images, multiplanar reconstructions (MPR), maximum-intensity projection (MIP), and three-dimensional volume-rendering (3D VR) images were used to assess left renal vein anomalies. Left renal vein anomalies were classified into four types according to their appearance: I) RLRV joining the inferior vena cava (IVC) in the orthotopic position; II) RLRV joining the IVC at level L4-L5; III) circumaortic or collar left renal vein; IV) RLRV joining the left common iliac vein. Results: RLRV was detected in 68 (3.6%) of the 1856 patients, with 26, 22, 17, and three of types I, II, III, and IV, respectively. Forty-four of the 68 patients with RLRV (65%) were in the group with urological symptoms, while 24 patients (35%) were in the group without urological symptoms. Compression of the RLRV was found in 16 patients in the urological symptoms group, while compression was detected in only three patients in the other group. This difference was statistically significant (P<0.05). The most common urological symptom was hematuria. The frequency of urological symptoms was higher in groups II and IV compared to the other groups. Conclusion: MDCT angiography with axial, MPR, MIP, and 3D VR images is effective in the detection of

  11. Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit

    NARCIS (Netherlands)

    Greuter, MJW; Dorgelo, J; Tukker, WGJ; Oudkerk, M

    2005-01-01

    Acquisition time plays a key role in the quality of cardiac multi-detector computed tomography (MDCT) and is directly related to the rotation time of the scanner. The purpose of this study is to examine the influence of heart rate and a multisector reconstruction algorithm on the image quality of co

  12. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  13. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)]. E-mail: Sabbara@partners.org; Desai, Jay C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Butler, Javed [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Reddy, Vivek [Division of Cardiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2006-03-15

    A sizable portion of ventricular tachycardia circuits are epicardial, especially in patients with non-ischemic cardiomyopathy, e.g. Chagas disease. Thus there is a growing interest among the electrophysiologists in transepicardial mapping and myocardial ablation for treatment of arrhythmias. However, increased epicardial fat can be a significant hindrance in procedural success as it can mimic infarct during mapping and can also decrease the effectiveness of ablation. Quantitative knowledge of epicardial fat pre-procedure can potentially significantly facilitate the conduct and outcomes of these procedures. In this study we assessed the epicardial fat distribution and thickness in vivo in 59 patients who underwent multi-detector computed tomography (MDCT) for coronary artery assessment using a 16-slice scanner. Multiplanar reconstructions were obtained in the ventricular short axis at the basal, mid ventricular, and near the apex level, and in a four-chamber view. In the short axis slices, we measured epicardial fat diameter in nine segments, and in the four-chamber view, it was measured in five segments. In grooved segments the maximum fat thickness was recorded, while in non-grooved segments thickness at three equally spaced points were averaged. The results were as follows starting clockwise: superior inter-ventricular (IV) groove (all measurements are in mm, in basal, mid ventricular, and apical levels, respectively) (11.2, 8.6, 7.3), left ventricular (LV) superior lateral wall (1.0, 1.5, 1.7), LV inferior lateral wall (1.3, 2.2, 3.5), inferior IV groove (9.2, 6.5, 6.1), right ventricular (RV) diaphragmatic wall (1.4, 0.2, 1.0), acute margin (9.2, 7.3, 7.8), RV anterior free wall inferior (6.8, 4.0, 4.7), RV anterior free wall superior (6.5, 3.2, 3.1), RV superior wall (5.6, 2.7, 4.0), We measured the following four-chamber segments: LV apex (2.8 mm), left atrio-ventricular (AV) groove (12.7), right AV groove (14.8), RV apex (4.8), and anterior IV groove (7

  14. Multidetector computed tomography findings of mesenteroaxial gastric volvulus combined with torsion of wandering spleen: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Kyung; Ku, Young Mi; Lee, Su Lim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of)

    2016-05-15

    Gastric volvulus, defined as an abnormal rotation of stomach, may be idiopathic or secondary to abnormal fixation of intraperitoneal visceral ligaments. Wandering spleen is a movable spleen resulting from absence or underdevelopment of the splenic supporting ligaments that suspend the spleen to its normal position in the left part of the supramesocolic compartment of the abdomen. Wandering spleen increases the risk of splenic torsion. Both gastric volvulus and splenic torsion are potentially life-threatening if not urgently managed with surgery. Prompt and accurate diagnosis based on multidetector computed tomography (MDCT) is crucial to prevent unforeseen complications. Gastric volvulus and coexistent torsion of wandering spleen is a very rare condition. Herein, we described a case of gastric volvulus associated with wandering spleen and intestinal non-rotation in a 15-year-old girl focusing on MDCT findings.

  15. Congenital varitans and anomalies of the pancreas and pancreatic duct: Imaging by magnetic resonance cholangiopancreaticography and multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Yener, Ouzlem [Dept. of Radiology, Tuerkiye Yueksek Ihtisas Hospital, Ankara (Turkmenistan); Erden, Aysel [Dept. of Radiology, Ankara University School of Medicine, Antalya (Turkmenistan); Tuerkoglu, Mehmet Akif [Dept. of General Surgery, Antalya University School of Medicine, Antalya (Turkmenistan)

    2013-12-15

    Though congenital anomalies of the pancreas and pancreatic duct are relatively uncommon and they are often discovered as an incidental finding in asymptomatic patients, some of these anomalies may lead to various clinical symptoms such as recurrent abdominal pain, nausea and vomiting. Recognition of these anomalies is important because these anomalies may be a surgically correctable cause of recurrent pancreatitis or the cause of gastric outlet obstruction. An awareness of these anomalies may help in surgical planning and prevent inadvertent ductal injury. The purpose of this article is to review normal pancreatic embryology, the appearance of ductal anatomic variants and developmental anomalies of the pancreas, with emphasis on magnetic resonance cholangiopancreaticography and multidetector computed tomography.

  16. Can contrast-enhanced ultrasonography replace multidetector-computed tomography in the detection of liver metastases from colorectal cancer?

    DEFF Research Database (Denmark)

    Larsen, Lars P.S.; Rosenkilde, Mona; Christensen, Henrik;

    2007-01-01

    consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions......PURPOSE: To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC). MATERIALS AND METHODS: Candidates for this prospective study were 461....... The examinations were interpreted blindly and the combination of US, CEUS, biphasic MDCT, IOUS, follow up and biopsy was the gold standard. RESULTS: Three hundred and sixty-five patients were included. All patients had undergone preoperative US, CEUS and MDCT and 65.5% had received IOUS. The gold standard found...

  17. Multidetector computed tomography in abdominal emergencies; Multidetektor-CT bei abdominellen Notfaellen

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, N.; Schreyer, A.G. [Universitaetsklinikum Regensburg (Germany). Institut fuer Roentgendiagnostik

    2009-06-15

    Abdominal emergencies encompass traumatic events in the region of the abdomen as well as the clinical term acute abdomen. Multidetector CT (MDCT) represents one of the most important imaging modalities for detection and correct diagnosis in such abdominal emergencies. Based on the acquired data MDCT allows a stable imaging of the abdomen in an extremely short time even in critically ill patients. Multiplanar reconstructions can be created based on the high resolution data allowing an impressive visualization of the pathology. In this review article the most important abdominal pathologies of the abdomen diagnosed by MDCT are presented with special emphasis on the liver, bile ducts, spleen and kidneys as well as the gastro-intestinal tract. Additionally, MDCT imaging of the individual organ regions will be dealt with in detail. (orig.) [German] Abdominelle Notfaelle beinhalten sowohl traumatische Ereignisse im Bereich des Bauchraums als auch den klinischen Begriff des ''akuten Abdomens''. Die Darstellung solcher Notfaelle mittels Multidetektor-Computertomographie (MDCT) ist eine leistungsfaehige Methode zur Detektion und richtigen Diagnosefindung der abdominellen Notfaelle. Die MDCT erlaubt eine stabile Bildgebung des Abdomens in extrem kurzer Zeit bei schwerkranken Patienten und zudem multiplanare Rekonstruktionen, basierend auf den akquirierten Rohdatensaetzen mit der Moeglichkeit, zusaetzlich Befunde anschaulicher zu visualisieren. In diesem Uebersichtsartikel werden die MDCT-Charakteristika verschiedener abdomineller Notfaelle der wichtigsten Organregionen des Abdomens, wie der Leber und der Gallenwege, des Pankreas, der Milz und der Niere sowie des Gastrointestinaltrakts erlaeutert. Dabei wird speziell auf die Multidetektor-CT-Technik der einzelnen Organregionen eingegangen. (orig.)

  18. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2013-12-15

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm{sup 3}, 90.4%) than in calcified plaque (median, 0.7 mm{sup 3}, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  19. Magnetic Resonance Enterography Findings in Crohn′s disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques

    OpenAIRE

    Parul Patel; Margaret Ormanoski; Hoadley, Kim M.

    2011-01-01

    Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD) in pediatric populations. With the advent of multidetector computed tomography (MDCT), it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well a...

  20. Avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores Post-operative evaluation of endovascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Fabiana Barroso Thomaz

    2008-08-01

    Full Text Available OBJETIVO: Este estudo tem como objetivo a avaliação pós-operatória do tratamento endovascular de aneurismas da aorta abdominal por angiotomografia com multidetectores. MATERIAIS E MÉTODOS: Foram analisadas, retrospectivamente, angiotomografias de 166 pacientes (137 homens e 29 mulheres com idade média de 73 anos portadores de aneurisma da aorta abdominal submetidos a terapêutica endovascular, no período de junho de 2005 a agosto de 2006. Os exames foram feitos em tomógrafo multidetector de 64 canais e os parâmetros adotados foram: colimação, 0,625 mm; pitch, 0,6-1; mAs, 300-400; kV, 120. Em todos os casos foi utilizado meio de contraste iodado não-iônico (350 mg/ml administrado por meio de bomba infusora, com fluxo de 4 ml/s a 5 ml/s e com volume variável de 70 ml a 100 ml. Os exames foram avaliados quanto à presença de complicações. RESULTADOS: Dos 166 exames realizados, 93 pacientes não apresentaram complicações e 73 apresentaram os seguintes achados: endoleak (n=37, trombose circunferencial da endoprótese (n=29, angulação (n=17, coleção no sítio de punção (n=10, migração da prótese (n=7, dissecção dos vasos de acesso (n=7 e oclusão (n=6. CONCLUSÃO: O endoleak foi a complicação mais prevalente em nosso estudo, sendo o tipo II o mais comum.OBJECTIVE: The present study was aimed at evaluating endovascularly treated abdominal aortic aneurysms by multidetector computed tomography angiography. MATERIALS AND METHODS: Multidetector computed tomography angiography studies of 166 patients were retrospectively analyzed. The sample included 137 men and 29 women with mean age of 73 years who had undergone endovascular treatment for abdominal aortic aneurysm in the period between June 2005 and August 2006. Images were acquired in a 64-channel multidetector tomograph adopting the following parameters: 0.625 mm collimation, pitch 0.6-1, 300-400 mAs, and 120 kV. A nonionic iodinated contrast agent (350 mg/ml was injected

  1. Advanced Gastric Cancer and Perfusion Imaging Using a Multidetector Row Computed Tomography: Correlation with Prognostic Determinants

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Huan; Pan, Zilai; Du, Lianjun; Yan, Chao; Ding, Bei; Song, Qi; Ling, Huawei; Chen, Kemin [Jiaotong University, Jiaotong (China)

    2008-04-15

    Objective : To investigate the relationship between the perfusion CT features and the clinicopathologically determined prognostic factors in advanced gastric cancer cases. Materials and Methods : A perfusion CT was performed on 31 patients with gastric cancer one week before surgery using a 16-channel multi-detector CT (MDCT) instrument. The data were analyzed with commercially available software to calculate tumor blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS). The microvessel density (MVD), was evaluated by immunohistochemical staining of the surgical specimens with anti-CD34. All of the findings were analyzed prospectively and correlated with the clinicopathological findings, which included histological grading, presence of lymph node metastasis, serosal involvement, distant metastasis, tumor, node, metastasis (TNM) staging, and MVD. The statistical analyses used included the Student's t-test and the Spearman rank correlation were performed in SPSS 11.5. Result : The mean perfusion values and MVD for tumors were as follows: BF (48.14+/-16.46 ml/100 g/min), BV (6.70+/-2.95 ml/100 g), MTT (11.75+/-4.02 s), PS (14.17+/-5.23 ml/100 g/min) and MVD (41.7+/-11.53). Moreover, a significant difference in the PS values was found between patients with or without lymphatic involvement (p = 0.038), as well as with different histological grades (p 0.04) and TNM stagings (p = 0.026). However, BF, BV, MTT, and MVD of gastric cancer revealed no significant relationship with the clinicopathological findings described above (p > 0.05). Conclusion : The perfusion CT values of the permeable surface could serve as a useful prognostic indicator in patients with advanced gastric cancer.

  2. Quantification of Global Left Ventricular Function: Comparison of Multidetector Computed Tomography and Magnetic Resonance Imaging. A Meta-analysis and Review of the Current Literature

    Energy Technology Data Exchange (ETDEWEB)

    Vleuten, P.A. van der; Willems, T.P.; Goette, M.J.; Tio, R.A.; Greuter, M.J.; Zijlstra, F.; Oudkerk, M. [Univ. Medical Centre Groningen (Netherlands). Depts. of Cardiology and Radiology

    2006-12-15

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.

  3. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  4. Magnetic Resonance Enterography Findings in Crohn's disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques.

    Science.gov (United States)

    Patel, Parul; Ormanoski, Margaret; Hoadley, Kim M

    2011-01-01

    Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD) in pediatric populations. With the advent of multidetector computed tomography (MDCT), it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well as demonstrate extra-enteric complications of IBD such as abscesses, fistulae, and sinus tracts. The major disadvantage of CT however is exposure to ionizing radiation, especially in IBD patients of the pediatric age group who maybe repeatedly imaged due to exacerbations. As a result, magnetic resonance enterography (MRE) is becoming increasingly important in the evaluation and follow-up of pediatric patients with IBD. This pictorial essay will summarize the multi-modality imaging findings of IBD with emphasis on MRE including the imaging protocol and procedure. For the purposes of this article, patients less than 17 years of age have been considered to represent the pediatric population.

  5. Discordant findings of dimercaptosuccinic acid scintigraphy in children with multi-detector row computed tomography-proven acute pyelonephritis

    Directory of Open Access Journals (Sweden)

    Jeongmin Lee

    2011-05-01

    Full Text Available Purpose : The diagnosis of acute pyelonephritis (APN is often difficult, as its clinical and biological manifestations are non-specific in children. If not treated quickly and adequately, however, APN may cause irreversible renal damage, possibly leading to hypertension and chronic renal failure. We were suspecting the diagnostic value of 99mTc-dimercaptosuccinic acid (DMSA scan by experiences and so compared the results of DMSA scan to those of multi-detector row computed tomography (MDCT. Methods : We retrospectively selected and analyzed 81 patients who were diagnosed as APN by MDCT during evaluation of their acute abdomen in emergency room and then received DMSA scan also for the diagnostic work-up of APN after admission. We evaluated the results of imaging studies and compared the diagnostic value of each method by age groups, &lt;2 years (n=45 and ?#242; years (n=36. Results : Among total 81 patients with MDCT-proven APN, DMSA scan was diagnostic only in 55 children (68%, while the remaining 26 children (32% showed false negative normal findings. These 26 patients were predominantly male and most of them, 19 (73.1% were &lt;2 years of age. Conclusion : DMSA scan holds obvious limitation compared to MDCT in depicting acute inflammatory lesions of kidney in children with APN, especially in early childhood less than 2 years of age. MDCT showed hidden lesions of APN, those were undetectable through DMSA scan in children.

  6. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography*

    Science.gov (United States)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; de Mello Júnior, Carlos Fernando; Silva Neto, Eulâmpio José; Negromonte, Gustavo Ramalho Pessoa; Duarte, Cláudia Martina Araújo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca

    2015-01-01

    Objective To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials and Methods Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. PMID:26811552

  7. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Severino Aires Araujo Neto

    2015-12-01

    Full Text Available Abstract Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT branches and hepatic arterial system (HAS, as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials and Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5% and 2 (3.3% patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08. A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS.

  8. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Catherine Yang

    2013-07-01

    Full Text Available Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications.

  9. Anatomical variations of the celiac trunk and hepatic arterial system: an analysis using multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Araujo Neto, Severino Aires; Franca, Henrique Almeida; Mello Junior, Carlos Fernando de; Silva Neto, Eulampio Jose; Negromonte, Gustavo Ramalho Pessoa; Duarte, Claudia Martina Araujo; Cavalcanti Neto, Bartolomeu Fragoso; Farias, Rebeca Danielly da Fonseca, E-mail: severinoaires@hotmail.com [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil)

    2015-11-15

    Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials And Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS. (author)

  10. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  11. Diagnostic performance of using effervescent powder for detection and grading of esophageal varices by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cansu, Aysegul, E-mail: drcansu@gmail.com [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Ahmetoglu, Ali; Kul, Sibel; Yukunc, Gokcen [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Fidan, Sami; Arslan, Mehmet [Department of Gastroenterology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Topbas, Murat [Department of Public Health, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey)

    2014-03-15

    Purpose: To investigate the effect of using effervescent powder (EP) on the efficacy of multi-detector computed tomography (MDCT) in detection and grading of esophageal varices in cirrhotic patients by considering endoscopy as the gold standard. Materials and methods: Ninety-two cirrhotic patients undergoing biphasic liver MDCT followed by upper gastrointestinal endoscopy within 4 weeks of MDCT were prospectively evaluated. The patients were divided into two groups before MDCT. The first group (n = 50) received effervescent powder (EP) before and during MDCT procedure and the second group did not receive (n = 42). The presence, size and grade of the esophageal varices were evaluated. MDCT findings were compared with endoscopic results. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of MDCT with EP and without EP were calculated and compared. Correlations between the grades of the varices for each group based on MDCT imaging and endoscopic grading were also evaluated. Results: The sensitivity, specificity, accuracy, PPV, and NPV of MDCT were 100%, 88%, 96%, 94%, and 100%, respectively, in the EP group, whereas they were 76%, 67%, 74%, 89%, and 43%, respectively, in the non-EP group. Correlations between the grades of the esophageal varices on MDCT and endoscopy were significant in both groups (r = 0.94, p < 0.001 for EP group and r = 0.70, p < 0.001 for non-EP group). Conclusion: During periodic CT scanning of cirrhotic patients, use of EP increases the success rate of MDCT for detection and grading of esophageal varices.

  12. Value of Multidetector Computed Tomography in Evaluation of Thoracic Venous Abnormalities among Pediatrics with Congenital Heart Disease

    Directory of Open Access Journals (Sweden)

    Dalia F Elbeih*, Mervat M El-Gohary *, Naglaa H Shebrya*,Mohammed A Saleh

    2013-04-01

    Full Text Available Introduction: Venous anomalies of the thorax can involve systemic or pulmonary veins and range from isolated incidental findings to components of more complex anomalies, most often congenital heart disease (CHD. Although echocardiography and catheter directed cardiac angiography are generally accepted as the primary imaging techniques for evaluation of CHD, CT and MRI are important complementary diagnostic tools. Multi-detector computed tomography (MDCT with its increasing availability and utility is now becoming a further method of imaging CHD. In light of its widespread availability, MDCT and 3D imaging are increasingly considered as a viable “one-stop shop” for preoperative imaging evaluation of cardiovascular structures in selected pediatric patients.Aim of the work: The aim of this work is to evaluate the role of MDCT in visualization of the thoracic venous system in pediatrics with congenital heart disease, show prevalence and types of venous anomalies and to compare this data with echocardiographic findings.Methods: The studied group included 30 cases referred to us by pediatric cardiologists to be examined by MSCT angiography of the heart and thoracic vessels. All the patients were known cases of congenital heart disease and underwent echocardiography. They were referred to answer specific anatomic question raised by inconclusive echocardiography, to assess suspected systemic and suspected pulmonary venous anomalies. All patients were subjected to full history taking, clinical examination and MDCT examination with CT lightspeed VCT XT 64-detectors row scanner (General Electric, Medical Systems, Milwaukee, Wisconsin, USA.Results: CTA findings had 77.8 % concordance with echocardiographic findings regarding SVC anomalies, 66.7 % concordance with echocardiography regarding IVC anomalies and 90 % concordance regarding pulmonary venous anomalies.Conclusion: Low dose protocol CTA is a promising method that complementary to Echocardioraphy

  13. Accuracy of multidetector row computed tomography for the diagnosis of acute bowel ischemia in a non-selected study population

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, Walter [University Hospital Basel, Institute of Diagnostic Radiology, Basel (Switzerland); Clinic Stephanshorn, Medical Radiology Center, St. Gallen (Switzerland); Hauser, Andreas; Steinbrich, Wolfgang [University Hospital Basel, Institute of Diagnostic Radiology, Basel (Switzerland)

    2004-12-01

    The diagnostic accuracy of multidetector row computed tomography for the prospective diagnosis of acute bowel ischemia in the daily clinical routine was analyzed. Two hundred ninety-one consecutive patients with an acute or subacute abdomen, examined by MDCT over a time period of 5 months, were included in the study. All original CT diagnoses made during the daily routine by radiological generalists were compared to the final diagnoses made by using all available medical information from endoscopies, surgical interventions, autopsies and follow-up. Finally, all CT examinations of patients with an initial CT diagnosis or a final diagnosis of bowel ischemia were reread by a radiologist specialized in abdominal imaging in order to analyze the CT findings and the reasons for initially false negative or false positive CT readings. Twenty-four patients out of 291 (8.2%) had acute bowel ischemia. The age of affected patients ranged from 50 to 94 years (mean age: 75.7 years). Eleven patients were male, and 13 female. Reasons for acute bowel ischemia were: arterio-occlusive (n=11), non-occlusive (n=5), strangulation (n=2), over-distension (n=3) and radiation (n=3). The prospective sensitivity, specificity, PPV and NPV of MDCT for the diagnosis of acute bowel ischemia in the daily routine were 79.17, 98.51, 90.48 and 98.15%. MDCT reaches a similarly high sensitivity in diagnosing acute bowel as angiography. Furthermore, it has the advantage of being helpful in most of its clinical differential diagnoses and of being less invasive with the consecutive possibility of being used earlier in the diagnostic process with all the resulting positive effects on the patients prognosis. Therefore, nowadays MDCT should probably be used as the first step imaging modality of choice in patients with suspected acute bowel ischemia. (orig.)

  14. Predictive value of multi-detector computed tomography for accurate diagnosis of serous cystadenoma: Radiologic-pathologic correlation

    Institute of Scientific and Technical Information of China (English)

    Anjuli A Shah; Nisha I Sainani; Avinash Kambadakone Ramesh; Zarine K Shah; Vikram Deshpande; Peter F Hahn; Dushyant V Sahani

    2009-01-01

    AIM:To identify multi-detector computed tomography (MDCT) features mos t predi c t i ve of serous cystadenomas (SCAs),correlating with histopathology,and to study the impact of cyst size and MDCT technique on reader performance.METHODS:The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs.Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or ≥3 cm) and scanning protocols (dedicated vs routine).RESULTS:28/164 cysts (mean size,39 mm;range,8-92 mm) were diagnosed as SCA on pathology.The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28,78.6%),surface lobulations (25/28,89.3%) and central scar (9/28,32.4%).Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P=0.0001).The sensitivity,specificity and PPV of central scar and of combined microcystic appearance and lobulations were 32.4%/100%/100% and 68%/100%/100%,respectively.The reader confidence was higher for lesions>3 cm (P=0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P>0.05).CONCLUSION:Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs.Microcystic morphology is the most significant CT feature in diagnosis of SCA.A combination of microcystic appearance and surface lobulations offers accuracy comparable to central scar with higher sensitivity.

  15. Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography

    Institute of Scientific and Technical Information of China (English)

    Hamza Sunman; Giray Kabak; Lale Tokgzolu; Ali Oto; Kudret Aytemir; Hikmet Yorgun; Uur Canpolat; Ali Taher; Edis Demiri; Tuncay Hazrolan; Leventahiner; Ergn B.Kaya

    2014-01-01

    Background Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. Methods The patients were examined by using dual-source MDCT and conventional coronary angiography. MDCT results were analyzed with regard to the severity (>50%stenosis) and morphology (non-calcified, mixed, or calcified) of coronary atherosclerotic plaques evaluated in a 16-segment model. Results In total, 181 patients (94 men and 87 women) with 2,687 coronary artery segments were examined with MDCT. Ninety three patients were older than 65 years of age (group A, 42 men) and 88 were younger (group B, 52 men). Two-hundred nine coronary artery segments (7.2%) were ex-cluded because of small distal coronary vessel segments and/or motion artifacts. The overall number of segments with non-diagnostic image quality was similar in both groups of patients. Of the 2,687 evaluated segments, 157 (5.8%) were significantly diseased, and 144 of them were correctly detected by MDCT. Diagnostic evaluation showed that the sensitivity, positive predictive value, specificity, and negative pre-dictive value were 89.5%, 62.5%, 96.0%, and 99.2%, respectively in group A, and 95.2%, 64.8%, 97.5%, and 99.8%in group B, respectively. In addition, detailed segment-based analyses in coronary segments with non-calcified, mixed and calcified plaques in both groups were simi-lar diagnostic accuracy. Conclusions Very high diagnostic accuracy observed in this study suggests that MDCT coronary angiography could be a suitable diagnostic tool for not only younger patients but also for older patients.

  16. Imaging features of intraductal papillary mucinous neoplasms of the pancreas in multi-detector row computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ling Tan; Ya-E Zhao; Deng-Bin Wang; Qing-Bing Wang; Jing Hu; Ke-Min Chen; Xia-Xing Deng

    2009-01-01

    AIM:To retrospectively evaluate the imaging features of pancreatic intraductal papillary mucinous neoplasms (IPMNs) in multi-detector row computed tomography (MDCT).METHODS:A total of 20 patients with pathologicallyconfirmed intraductal papillary mucinous neoplasms (IPMNs) were included in this study.Axial MDCT images combined with CT angiography (CTA) and multiplanar volume reformations (MPVR) or curved reformations (CR) were preoperatively acquired.Two radiologists (Tan L and Wang DB) reviewed all the images in consensus using an interactive picture archiving and communication system.The disputes in readings were resolved through consultation with a third experienced radiologist (Chen KM).Finally,the findings and diagnoses were compared with the pathologic results.RESULTS:The pathological study revealed 12 malignant IPMNs and eight benign IPMNs.The diameters of the cystic lesions and main pancreatic ducts (MPDs) were significantly larger in malignant IPMNs compared with those of the benign IPMNs (P<0.05).The combinedtype IPMNs had a higher rate of malignancy than the other two types of IPMNs (P<0.05).Tumors with mural nodules and thick septa had a significantly higher incidence of malignancy than tumors without these features (P<0.05).Communication of side-branch IPMNs with the MPD was present in nine cases at pathologic examination.Seven of them were identified from CTA and MPVR or CR images.From comparison with the pathological diagnosis,the sensitivity,specificity,and accuracy of MDCT in characterizing the malignancy of IPMN of the pancreas were determined to be 100%,87.5% and 95%,respectively.CONCLUSION:MDCT with CTA and MPVR or CR techniques can elucidate the imaging features of IPMNs and help predict the malignancy of these tumors.

  17. Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Lei [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Ma, Xiaohai, E-mail: maxi8238@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China); Feuchtner, Gudrun Maria [Department of Radiology II, Innsbruck Medical University, Innsbruck (Austria); Zhang, Chen; Fan, Zhanming [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, No. 2 Anzhen Rd Beijing (China)

    2014-10-15

    Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 ± 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as “dense” (areas with clear defined borders) or “diffuse” and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, −3.85%; lower and upper limits of agreement, −13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning.

  18. Cuantificación del signo de la arteria cerebral media hiperdensa con TCMD Quantification of hyperdense middle cerebral artery sign by multidetector computed tomography (MDCT.

    Directory of Open Access Journals (Sweden)

    Francisco Meli

    2011-12-01

    CT scans with a 64-row multi-detector scanner (Brilliance 64; Philips Medical Systems. Absolute quantitative analysis was assessed by tracking tissue density of the MCA segment using region of interests. For relative quantification, density in the same segment of the contra- lateral MCA was measured to calculate the difference between both arteries. Results. In cases, mean density of affected MCA (62.5 HU, 99% CI: 46.2 - 78.7 was greater than that of the contra-lateral MCA segments (39.3 HU, 99% CI: 33.3-45.3 (p<0.0004 and also greater than that of controls (44.7 HU, 99% CI: 37.4-52 (p=0.0045. In relative quantification, the mean difference between density of the affected MCA and that of contra-lateral MCA in cases was 23.2 HU (95% CI: 11.7-34.7, while in controls the mean difference between the right MCA density and the left MCA density was 5.2 HU (95% CI: 2.4-8.4 (difference: 17.8 HU, p = 0.0062, 95% CI: 6.8-28.8. Conclusion. We showed significant (relative and absolute differences in MCA density in patients with suspected acute ischemic stroke as compared to normal subjects.

  19. A STUDY ON DIAGNOSTIC ACCURACY OF BIOCHEMICAL MARKERS AND TRANS–ABDOMINAL ULTRASONOGRAPHY IN COMPARISON TO MULTI-DETECTOR COMPUTED TOMOGRAPHY IN DETECTION OF ACUTE PANCREATITIS

    Directory of Open Access Journals (Sweden)

    Biplab Debbarma

    2016-07-01

    Full Text Available Acute pancreatitis is an acute, mainly diffuse, inflammatory process of the pancreas. Computed Tomography (CT scan is the modality of choice for diagnosis of acute pancreatitis. But non-availability of Computed Tomography (CT scan in all health facilities made detection of acute pancreatitis is problemsome. OBJECTIVES 1. To assess the diagnostic accuracy of Biochemical Markers and Trans-Abdominal Ultrasonography in comparison to Multidetector Computed Tomography in diagnosis of acute pancreatitis. 2. To compare the findings of Trans-Abdominal Ultrasonography with Multidetector Computed Tomography. MATERIALS AND METHODS 100 clinically suspected for acute pancreatitis patients were tested for abnormal biochemical markers, followed by examined by USG and then by MDCT in Radiodiagnosis Department of AGMC and GBP Hospital and findings were compared. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. RESULTS The sensitivity and specificity of trans-abdominal ultrasonography was calculated as 75% (CI 64.06% - 84.01% and 100% (CI 83.16%-100%. CONCLUSION USG had similar sensitivity, but higher specificity value than serum markers (Amylase and Lipase.

  20. Bone Mineral Density Estimations From Routine Multidetector Computed Tomography: A Comparative Study of Contrast and Calibration Effects

    Science.gov (United States)

    Kaesmacher, Johannes; Liebl, Hans; Baum, Thomas; Kirschke, Jan Stefan

    2017-01-01

    Introduction Phantom-based (synchronous and asynchronous) and phantomless (internal tissue calibration based) assessment of bone mineral density (BMD) in routine MDCT (multidetector computed tomography) examinations potentially allows for diagnosis of osteoporosis. Although recent studies investigated the effects of contrast-medium application on phantom-calibrated BMD measurements, it remains uncertain to what extent internal tissue-calibrated BMD measurements are also susceptible to contrast-medium associated density variation. The present study is the first to systemically evaluate BMD variations related to contrast application comparing different calibration techniques. Purpose To compare predicative performance of different calibration techniques for BMD measurements obtained from triphasic contrast-enhanced MDCT. Materials and Methods Bone mineral density was measured on nonenhanced (NE), arterial (AR) and portal-venous (PV) contrast phase MDCT images of 46 patients using synchronous (SYNC) and asynchronous (ASYNC) phantom calibration as well as internal calibration (IC). Quantitative computed tomography (QCT) served as criterion standard. Density variations were analyzed for each contrast phase and calibration technique, and respective linear fitting was performed. Results Both asynchronous calibration-derived BMD values (NE-ASYNC) and values estimated using IC (NE-IC) on NE MDCT images did reasonably well in predicting QCT BMD (root-mean-square deviation, 8.0% and 7.8%, respectively). Average NE-IC BMD was 2.7% lower when compared with QCT (P = 0.017), whereas no difference could be found for NE-ASYNC (P = 0.957). All average BMD estimates derived from contrast-enhanced scans differed significantly from QCT BMD (all P 6.0 mg/mL). All regression fits revealed a consistent linear dependency (R2 range, 0.861–0.963). Overall accuracy and goodness of fit tended to decrease from AR to PV contrast phase. Highest precision and best linear fit could be reached

  1. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  2. Effect of obesity on coronary artery plaque using 64 slice multidetector cardiac computed tomography angiography.

    Science.gov (United States)

    Isma'eel, Hussain; Tellalian, David; Hamirani, Yasmin S; Kadakia, Jigar; Nasir, Khurram; Budoff, Matthew J

    2010-04-30

    Patients with a coronary artery calcification score (CACS) of zero and an intermediate risk of coronary artery disease have been shown to have a low prevalence of non-calcified coronary artery plaque (NCP). 181 consecutive patients with CAC 'zero', undergoing cardiac computed tomography angiography (CCTA) angiography at our center were evaluated. Presence of detectable NCP on CCTA in these patients was 13.8%. Mild non-obstructive disease (50%). Traditional risk factors were not found to be associated with the presence of NCP. However higher body mass index (BMI) was strongly found to be associated with NCP (31.6 in patients with NCP vs. 27.6 kg/m(2) in patients without NCP, pNCP as compared to normal BMI (p<0.05).

  3. Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Ruifang Zhang

    Full Text Available BACKGROUND AND PURPOSE: Accurate measurement of aortic annulus diameter is crucial for choosing suitable prosthetic size for transcatheter aortic valve implantation (TAVI. Several imaging methods are available for the measurement, but significant variability between different modalities has been observed. The purpose of this study was to systematically compare the measurements of aortic annulus diameter between multi-detector computed tomography (MDCT, transthoracic echocardiography (TTE, and transesophegeal echocardiography (TEE. METHODS: PubMed and EMBASE databases between January 2000 and January 2012 were searched. We extracted data from eligible studies evaluating the aortic annulus diameter by MDCT and echocardiography (TTE, TEE, or both. We performed a random-effects meta-analysis to calculate the weighted mean differences of aortic annulus diameter measurement between MDCT, TTE, and TEE. RESULTS: A total of 10 eligible studies involving 581 subjects with aortic valve stenosis were included. Aortic annulus diameter measured on coronal view by MDCT (25.3±0.52 mm was respectively larger than that measured on sagittal view by MDCT (22.7±0.37 mm, TTE (22.6±0.28 mm, and TEE (23.1±0.32 mm. The weighted mean difference of aortic annulus diameter between coronal view by MDCT and TTE these two methods was 2.97 mm, followed by the weighted mean difference of 2.53 mm between coronal view and sagittal view by MDCT, and the mean difference of 1.74 mm between coronal view on MDCT and TEE (P<0.0001 for all. The weighted mean difference of aortic annulus diameter measurement between TEE and TTE was significant but somewhat small (0.45 mm, P = 0.007. CONCLUSION: Aortic annulus diameter measured on coronal view by MDCT was robustly and significantly larger than that obtained on sagittal view by MDCT, TTE, or TEE. Such variability of aortic annulus diameter measurement by different imaging modalities cannot be ignored when developing optimal

  4. Prevalence of extracardiac findings in the evaluation of ischemic heart disease by multidetector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Jeong-Hwan Cho; Jong-Seon Park; Dong-Gu Shin; Young-Jo Kim; Sang-Hee Lee; Yoon-Jung Choi; Ihn-Ho Cho

    2013-01-01

    Objective Multidector computed tomography (MDCT) is now commonly used for the evaluation of coronary artery disease. Because MDCT images include many non-cardiac organs and the patient population evaluated is highly susceptible to extracardiac diseases, this study was designed to evaluate the prevalence of extracardiac findings in the MDCT evaluation of ischemic heart disease. Methods From March 2007 to March 2008, a total of six-hundred twenty patients, who underwent 64-slice MDCT evaluations for chest pain, or dyspnea, were enrolled in this study. Cardiac and non-cardiac findings were comprehensively evaluated by a radiologist. Results Enrolled patients included 306 men (49.4%), with a mean age of 66 years. Significant coronary artery stenosis was found in 41.6%of the patients. A total of 158 extracardiac findings were observed in 110 (17.7%) patients. Commonly involved extracardiac organs were lung (36.7%), hepatobiliary system (21.5%), thyroid (19.6%), kidney (10.8%), spine (9.7%) and breast (0.6%). Of those 110 patients, 50 (45.5%) patients underwent further diagnostic investigations. Malignant disease was detected in three (2.7%) patients (lung cancer, pancreatic cancer, and thyroid cancer). Conclusions Extracardiac findings are frequently present and should be a concern in the MDCT evaluation of chest pain syndrome.

  5. Criteria for establishing shielding of multi-detector computed tomography (MDCT) rooms.

    Science.gov (United States)

    Verdun, F R; Aroua, A; Baechler, S; Schmidt, S; Trueb, P R; Bochud, F O

    2010-01-01

    The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

  6. Multiparametric multidetector computed tomography scanning on suspicion of hyperacute ischemic stroke: validating a standardized protocol Avaliação multiparamétrica por tomografia computadorizada multidetectores na suspeita de isquemia cerebral hiperaguda: validando um protocolo padronizado

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2013-06-01

    Full Text Available Multidetector computed tomography (MDCT scanning has enabled the early diagnosis of hyperacute brain ischemia. We aimed at validating a standardized protocol to read and report MDCT techniques in a series of adult patients. The inter-observer agreement among the trained examiners was tested, and their results were compared with a standard reading. No false positives were observed, and an almost perfect agreement (Kappa>0.81 was documented when the CT angiography (CTA and cerebral perfusion CT (CPCT map data were added to the noncontrast CT (NCCT analysis. The inter-observer agreement was higher for highly trained readers, corroborating the need for specific training to interpret these modern techniques. The authors recommend adding CTA and CPCT to the NCCT analysis in order to clarify the global analysis of structural and hemodynamic brain abnormalities. Our structured report is suitable as a script for the reproducible analysis of the MDCT of patients on suspicion of ischemic stroke.A tomografia computadorizada multidetectores (TCMD permitiu o diagnóstico precoce de isquemia cerebral hiperaguda. O presente estudo objetivou validar a interpretação e a descrição padronizada de um protocolo de TCMD multiparamétrica em uma série de pacientes adultos. A concordância entre os examinadores foi testada, e seus resultados confrontados com uma leitura padrão. Não foram observados resultados falso-positivos, e foi documentado um elevado grau de concordância (Kappa>0,81 quando os dados da angiotomografia (ATC e dos mapas de perfusão cerebral por TC (PCTC foram adicionados à análise da TC sem contraste (TCSC. A concordância interobservador foi superior para os leitores melhor treinados, corroborando a necessidade de formação específica para a interpretação dos exames. Os autores recomendam acrescer a interpretação da ATC e da PCTC à análise da TCSC, visando à análise global das anormalidades cerebrais estruturais e hemodin

  7. COMPARATIVE STUDY OF MULTIDETECTOR COMPUTED TOMOGRAPHY AND ULTRASONOGRAPHY FINDINGS IN BLUNT ABDOMINAL TRAUMA

    Directory of Open Access Journals (Sweden)

    Okram Pusparani Devi

    2016-07-01

    Full Text Available BACKGROUND Blunt abdominal trauma usually has low sensitivity on physical examination and also subtle clinical manifestations. Improved resolution of the ultrasound machines and availability of multiple frequency probes has improved the specificity of ultrasound evaluation in blunt abdominal trauma. Despite this about 50% of the solid organ injuries are missed. Computed tomography has been used with better specificity to evaluate patients with blunt abdominal trauma who are FAST (Focused Assessment with Sonography for Trauma positive as well as indeterminate and clinically suspicious cases of solid organ, hollow viscera, spine and pelvic injury. AIM AND OBJECTIVES The purpose of this study was to determine sensitivity, specificity and diagnostic accuracy of USG and MDCT and compare the efficacy of the two imaging modalities in blunt abdominal trauma. METHOD A prospective observational study of 100 patients was conducted in the Department of Radiodiagnosis, Bharati Hospital, Pune. All patients with blunt abdominal trauma were included. FAST screening was done with ANTARES ACUSON SIEMENS followed by MDCT on 16-Slice Philips Brilliance. Sensitivity, specificity and diagnostic accuracy of USG and CT were determined by comparing with laparotomy findings. RESULTS Although USG was sensitive, specific and accurate in detecting free fluid in abdomen, CT was found better and also superior in detecting solid organ injury in patients with blunt abdominal trauma. CONCLUSION Ultrasound is an efficient modality in the initial evaluation of blunt abdominal trauma. But CT is the superior diagnostic modality and must be performed in symptomatic patient with ultrasound negative report and suboptimal ultrasound examination. CT scan thoroughly scrutinizes entire abdomen including retroperitoneum with additional assessment of thoracic trauma and bony pelvic trauma. Hence, CT increases diagnostic confidence and influences management decision.

  8. Simple area-based measurement for multidetector computed tomography to predict left ventricular size

    Energy Technology Data Exchange (ETDEWEB)

    Schlett, Christopher L.; Kwait, Dylan C.; Mahabadi, Amir A.; Hoffmann, Udo [Massachusetts General Hospital, and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Bamberg, Fabian [Massachusetts General Hospital, and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); University Hospitals Munich, and Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); O' Donnell, Christopher J. [Lung and Blood Institute' s Framingham Heart Study, National Heart, Framingham (United States); Fox, Caroline S. [Lung and Blood Institute' s Framingham Heart Study, National Heart, Framingham (United States); Brigham and Women' s Hospital, and Harvard Medical School, Division of Endocrinology, Metabolism, and Diabetes, Department of Medicine, Boston, MA (United States)

    2010-07-15

    Measures of left ventricular (LV) mass and dimensions are independent predictors of morbidity and mortality. We determined whether an axial area-based method by computed tomography (CT) provides an accurate estimate of LV mass and volume. A total of 45 subjects (49% female, 56.0 {+-} 12 years) with a wide range of LV geometry underwent contrast-enhanced 64-slice CT. LV mass and volume were derived from 3D data. 2D images were analysed to determine LV area, the direct transverse cardiac diameter (dTCD) and the cardiothoracic ratio (CTR). Furthermore, feasibility was confirmed in 100 Framingham Offspring Cohort subjects. 2D measures of LV area, dTCD and CTR were 47.3 {+-} 8 cm{sup 2}, 14.7 {+-} 1.5 cm and 0.54 {+-} 0.05, respectively. 3D-derived LV volume (end-diastolic) and mass were 148.9 {+-} 45 cm{sup 3} and 124.2 {+-} 34 g, respectively. Excellent inter- and intra-observer agreement were shown for 2D LV area measurements (both intraclass correlation coefficients (ICC) = 0.99, p < 0.0001) and could be confirmed on non-contrast CT. The measured 2D LV area was highly correlated to LV volume, mass and size (r = 0.68; r = 0.73; r = 0.82; all p < 0.0001, respectively). On the other hand, CTR was not correlated to LV volume, mass, size or 2D LV area (all p > 0.27). Compared with traditionally used CTR, LV size can be accurately predicted based on a simple and highly reproducible axial LV area-based measurement. (orig.)

  9. Calcium score of small coronary calcifications on multidetector computed tomography: Results from a static phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Groen, J.M., E-mail: jaap.groen@slaz.nl [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Kofoed, K.F., E-mail: kkofoed@dadlnet.dk [Department of Cardiology and Radiology, Rigshospitalet, University of Copenhagen (Denmark); Zacho, M., E-mail: dls332089@vip.cybercity.dk [Department of Cardiology and Radiology, Rigshospitalet, University of Copenhagen (Denmark); Vliegenthart, R., E-mail: r.vliegenthart@umcg.nl [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Willems, T.P., E-mail: t.p.willems@umcg.nl [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands); Greuter, M.J.W., E-mail: m.j.w.greuter@umcg.nl [Department of Radiology, University of Groningen, University Medical Center Groningen (Netherlands)

    2013-02-15

    Introduction: Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which enables establishment of a calcium scoring protocol for MDCT that yields a calcium score comparable to the EBT values and to the physical mass. Materials and methods: A phantom containing 100 small calcifications ranging from 0.5 to 2.0 mm was scanned on EBT using a standard coronary calcium protocol. In addition, the phantom was scanned on a 320-row MDCT scanner using different scanning, reconstruction and scoring parameters (tube voltage 80–135 kV, slice thickness 0.5–3.0 mm, reconstruction kernel FC11–FC15 and threshold 110–150 HU). The Agatston and mass score of both modalities was compared and the influence of the parameters was assessed. Results: On EBT the Agatston and mass scores were between 0 and 20, and 0 and 3 mg, respectively. On MDCT the Agatston and mass scores were between 0 and 20, and 0 and 4 mg, respectively. All parameters showed an influence on the calcium score. The Agatston score on MDCT differed 52% between the 80 and 135 kV, 65% between 0.5 and 3.0 mm and 48% between FC11 and FC15. More calcifications were detected with a lower tube voltage, a smaller slice thickness, a sharper kernel and a lower threshold. Based on these observations an acquisition protocol with a tube voltage of 100 kV and two reconstructions protocols were defined with a FC12 reconstruction kernel; one with a slice thickness of 3.0 mm and a one with a slice thickness of 0.5 mm. This protocol yielded an Agatston score as close to the EBT as possible, but also a mass score as close to the physical phantom value as possible, respectively. Conclusion: With the new phantom one acquisition protocol and two reconstruction protocols can be defined which produces

  10. High-resolution computed tomography in patients with atypical 'cardiac' chest pain: a study investigating patients at 10-year cardiovascular risks defined by the Framingham and PROCAM scores

    Institute of Scientific and Technical Information of China (English)

    Choon Kiat ANG; Kui Hian SIM; Alan Yean Yip FONG; Sze Piaw CHIN; Tiong Kiam ONG; Seyfarth M Tobias; Wei Ling CHAN; Chee Khoon LIEW; Rapaee ANNUAR; Houng Bang LIEW

    2006-01-01

    Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary angiography. The latest 64-row multi-detector computed tomography (MDCT) technology is non-invasive, has high specificity and negative predictive values for the detection of significant coronary disease. Our aim was to investigate if this modality can provide more information in the assessment of outpatients with ACCP in addition to established cardiovascular risk scores. Methods Seventy consecutive patients presenting to the outpatient clinic with ACCP underwent 64-row MDCT scan of the coronary arteries. They were categorized into low, medium or high risk groups based upon the Framingham and PROCAM scores. We defined a clinically abnormal MDCT scan as coronary stenosis =50% or calcium score >400 Agatston. Results Fifty-three (75.7%) patients did not have clinically abnormal scans. Framingham score classified 43 patients as low-risk while PROCAM classified 59 patients as low-risk. MDCT scans were abnormal for 18.6% and 22.0% of the respective low-risk group of patients. For patients with medium-to-high risk, 33.3% and 36.4% of Framingham and PROCAM patient groups respectively had abnormal MDCT scans. Conclusion MDCT adds valuable information in the assessment of patients with ACCP by identifying a significant proportion of patients categorized as low-risk to have underlying significant coronary stenosis and coronary calcification by established cardiovascular risk scores.

  11. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution : A cardiac phantom study

    NARCIS (Netherlands)

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-01-01

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative me

  12. Endovascular treatment of thoracic aortic diseases: Follow-up and complications with multi-detector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)], E-mail: r.iezzi@rad.unich.it; Cotroneo, Antonio Raffaele; Marano, Riccardo; Filippone, Antonella; Storto, Maria Luigia [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2008-03-15

    Endovascular procedures with placement of stent-graft has become an accepted alternative to traditional open surgery for treatment of descending thoracic aortic aneurysms, ulcers, post-traumatic rupture, or complications of type-B dissection, due to significant reduction in perioperative mortality, rate of complications and length of hospitalization. Moreover, increasing operator experience and continuous advances in stent-graft technology are making treatment of a wider range of cases possible with redefinition of guidelines for endovascular stent-graft. The feasibility of endovascular stent-graft is mainly dependent on anatomic factors which represent the important predictors of the success of this procedure as well as on strictly follow-up in order to obtain early detection and treatment of eventual complications. Multi-detector CT-angiography is a fast, safe, and minimally invasive imaging technique that represents the standard of reference in the follow-up of patients who have undergone endovascular stent-graft, as it is effective and specific in the detection of procedure-correlated complications. The purpose of this article is to give a brief review of those techniques most commonly used for endovascular treatment of thoracic aortic diseases together with a more detailed description of post-procedural complications and their appearance on multi-detector CT-angiography.

  13. Dataset of calcified plaque condition in the stenotic coronary artery lesion obtained using multidetector computed tomography to indicate the addition of rotational atherectomy during percutaneous coronary intervention.

    Science.gov (United States)

    Akutsu, Yasushi; Hamazaki, Yuji; Sekimoto, Teruo; Kaneko, Kyouichi; Kodama, Yusuke; Li, Hui-Ling; Suyama, Jumpei; Gokan, Takehiko; Sakai, Koshiro; Kosaki, Ryota; Yokota, Hiroyuki; Tsujita, Hiroaki; Tsukamoto, Shigeto; Sakurai, Masayuki; Sambe, Takehiko; Oguchi, Katsuji; Uchida, Naoki; Kobayashi, Shinichi; Aoki, Atsushi; Kobayashi, Youichi

    2016-06-01

    Our data shows the regional coronary artery calcium scores (lesion CAC) on multidetector computed tomography (MDCT) and the cross-section imaging on MDCT angiography (CTA) in the target lesion of the patients with stable angina pectoris who were scheduled for percutaneous coronary intervention (PCI). CAC and CTA data were measured using a 128-slice scanner (Somatom Definition AS+; Siemens Medical Solutions, Forchheim, Germany) before PCI. CAC was measured in a non-contrast-enhanced scan and was quantified using the Calcium Score module of SYNAPSE VINCENT software (Fujifilm Co. Tokyo, Japan) and expressed in Agatston units. CTA were then continued with a contrast-enhanced ECG gating to measure the severity of the calcified plaque condition. We present that both CAC and CTA data are used as a benchmark to consider the addition of rotational atherectomy during PCI to severely calcified plaque lesions.

  14. Dataset of calcified plaque condition in the stenotic coronary artery lesion obtained using multidetector computed tomography to indicate the addition of rotational atherectomy during percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Yasushi Akutsu

    2016-06-01

    Full Text Available Our data shows the regional coronary artery calcium scores (lesion CAC on multidetector computed tomography (MDCT and the cross-section imaging on MDCT angiography (CTA in the target lesion of the patients with stable angina pectoris who were scheduled for percutaneous coronary intervention (PCI. CAC and CTA data were measured using a 128-slice scanner (Somatom Definition AS+; Siemens Medical Solutions, Forchheim, Germany before PCI. CAC was measured in a non-contrast-enhanced scan and was quantified using the Calcium Score module of SYNAPSE VINCENT software (Fujifilm Co. Tokyo, Japan and expressed in Agatston units. CTA were then continued with a contrast-enhanced ECG gating to measure the severity of the calcified plaque condition. We present that both CAC and CTA data are used as a benchmark to consider the addition of rotational atherectomy during PCI to severely calcified plaque lesions.

  15. Multidetector computed tomography angiography in clinically suspected hyperacute ischemic stroke in the anterior circulation: an etiological workup in a cohort of Brazilian patients

    Directory of Open Access Journals (Sweden)

    Felipe Torres Pacheco

    2015-05-01

    Full Text Available Objective The potential of computed tomography angiography (CTA was assessed for early determination of stroke subtypes in a Brazilian cohort of patients with stroke. Method From July 2011 to July 2013, we selected patients with suspected hyperacute stroke (< 6 hours. Intracranial and cervical arteries were scrutinized on CTA and their imaging features were correlated with concurrent subtype of stroke. Results Stroke was documented in 50/106 selected patients (47.2% based on both clinical grounds and imaging follow-up (stroke group, with statistically significant arterial stenosis and vulnerable plaques on CTA. Intracranial large artery disease was demonstrated in 34% of patients in the stroke group. Partial territorial infarct prevailed (86% while artery-to-artery embolization was the most common stroke mechanism (52%. Conclusion Multidetector CTA was useful for the etiologic work-up of hyperacute ischemic stroke and facilitated the knowledge about the topographic pattern of brain infarct in accordance with its causative mechanism.

  16. Efficacy of Multidetector-Row Computed Tomography as a Practical Tool in Comparison to Invasive Procedures for Visualization of the Biliary Obstruction

    Science.gov (United States)

    Taheri, Abdolmajid; Rostamzadeh, Ayoob; Gharib, Alireza; Fatehi, Daryoush

    2016-01-01

    Introduction: Recently, multidetector computed tomography (MDCT) has been introduced into clinical practice. MDCT has become the noninvasive diagnostic test of choice for detailed evaluation of biliary obstruction. Aim: the main objective of the present study was to evaluate the diagnostic value of MDCT compared to invasive procedures for detecting biliary obstruction causes. Material and Methods: Since February 2009 until May 2011 fifty biliary obstruction patients based on clinical, laboratory or ultrasonographic findings, were evaluated by Multidetector-row computed tomography. The causes of biliary obstruction, which was identified using. MDCT were classified into three categories: calculus, benign stricture, and malignancy. Final diagnosis was conducted based on percutaneous transhepatic cholangiography (PTC), endoscopic retrograde cholangiopancreatography, biopsy, or surgery. The MDCT diagnosis and were compared with the final diagnosis. Results: A correct diagnosis of causes of biliaryobstruction was made on the basis of MDCT findings for 44 of the total 50 patients. Two patients with chronic pancreatitis were incorrectly diagnosed with a pancreatic head adenocarcinoma on the basis of MDCT findings. One patient with biliary stone was incorrectly diagnosed with a periampullary adenocarcinoma on the basis of MDCT findings. The Sensitivity, specificity and accuracy of MDCT in the diagnosis of causes of biliary obstruction were 94.12% and87.87% and94.6% respectively. Conclusion: Based on the findings of this study MDCT has an excellent image quality, providing valuable information about the biliary tree and other abdominal organs. The use of advanced image processing, including maximum intensity projection and multiplanar reconstruction (especially coronal or sagittal reformatted images), allows superior visualization of the biliary tree and vascular structures. Three-dimensional reconstruction images complement axial images by providing a more anatomically

  17. Multidetector computed tomography-guided treatment strategy in patients with non-ST elevation acute coronary syndromes: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Dorgelo, J.; Willems, T.P.; Ooijen, P.M.A. van; Oudkerk, M. [University Hospital Groningen, Department of Radiology, Groningen (Netherlands); Geluk, C.A.; Zijlstra, F. [University Hospital Groningen, Department of Cardiology, Groningen (Netherlands)

    2005-04-01

    Patients with non-ST elevation acute coronary syndrome (ACS) and evidence of myocardial ischaemia are scheduled for coronary angiography (CAG). In most patients CAG remains a single diagnostic procedure only. A prospective study was performed to evaluate whether 16-slice multidetector CT (MDCT) could predict treatment of the patients and to determine how many CAGs could have been prevented by MDCT scanning prior to CAG. Twenty-two patients with ACS were scanned prior to CAG. Based on MDCT data, a fictive treatment was proposed and compared to CAG-based treatment. Excellent accuracy was observed to detect significant stenoses using MDCT (sensitivity 94%, specificity 96%). In 45%, no PCI was performed during CAG, because of the absence of significant coronary artery disease (27%) or severe coronary artery disease, demanding CABG (18%). MDCT predicted correct treatment in 86%. By using MDCT data, 32% of the CAGs could have been prevented. (orig.)

  18. Usefulness of 40-slice multidetector row computed tomography to detect coronary disease in patients prior to cardiac valve surgery

    Energy Technology Data Exchange (ETDEWEB)

    Pouleur, Anne-Catherine; Polain de Waroux, Jean-Benoit le; Kefer, Joelle; Pasquet, Agnes; Vanoverschelde, Jean-Louis; Gerber, Bernhard L. [Cliniques Universitaires St. Luc UCL, Cardiology Division, Woluwe St. Lambert (Belgium); Coche, Emmanuel [Cliniques Universitaires St. Luc UCL, Radiology Division, Woluwe St. Lambert (Belgium)

    2007-12-15

    Preoperative identification of significant coronary artery disease (CAD) in patients prior to valve surgery requires systematic invasive coronary angiography. The purpose of this current prospective study was to evaluate whether exclusion of CAD by multi-detector CT (MDCT) might potentially avoid systematic cardiac catheterization in these patients. Eighty-two patients (53 males, 62 {+-} 13 years) scheduled to undergo valve surgery underwent 40-slice MDCT before invasive quantitative coronary angiography (QCA). According to QCA, 15 patients had CAD (5 one-vessel, 6 two-vessel and 4 three-vessel disease). The remaining 67 patients had no CAD. On a per-vessel basis, MDCT correctly identified 27/29 (sensitivity 93%) vessels with and excluded 277/299 vessels (specificity 93%) without CAD. On a per-patient basis, MDCT correctly identified 14/15 patients with (sensitivity 93%) and 60/67 patients without CAD (specificity 90%). Positive and negative predictive values of MDCT were 67% and 98%. Performing invasive angiography only in patients with abnormal MDCT might have avoided QCA in 60/82 (73%). MDCT could be potentially useful in the preoperative evaluation of patients with valve disease. By selecting only those patients with coronary lesions to undergo invasive coronary angiography, it could avoid cardiac catheterization in a large number of patients without CAD. (orig.)

  19. Usefulness of 40-slice multidetector row computed tomography to detect coronary disease in patients prior to cardiac valve surgery.

    Science.gov (United States)

    Pouleur, Anne-Catherine; le Polain de Waroux, Jean-Benoît; Kefer, Joëlle; Pasquet, Agnès; Coche, Emmanuel; Vanoverschelde, Jean-Louis; Gerber, Bernhard L

    2007-12-01

    Preoperative identification of significant coronary artery disease (CAD) in patients prior to valve surgery requires systematic invasive coronary angiography. The purpose of this current prospective study was to evaluate whether exclusion of CAD by multi-detector CT (MDCT) might potentially avoid systematic cardiac catheterization in these patients. Eighty-two patients (53 males, 62 +/- 13 years) scheduled to undergo valve surgery underwent 40-slice MDCT before invasive quantitative coronary angiography (QCA). According to QCA, 15 patients had CAD (5 one-vessel, 6 two-vessel and 4 three-vessel disease). The remaining 67 patients had no CAD. On a per-vessel basis, MDCT correctly identified 27/29 (sensitivity 93%) vessels with and excluded 277/299 vessels (specificity 93%) without CAD. On a per-patient basis, MDCT correctly identified 14/15 patients with (sensitivity 93%) and 60/67 patients without CAD (specificity 90%). Positive and negative predictive values of MDCT were 67% and 98%. Performing invasive angiography only in patients with abnormal MDCT might have avoided QCA in 60/82 (73%). MDCT could be potentially useful in the preoperative evaluation of patients with valve disease. By selecting only those patients with coronary lesions to undergo invasive coronary angiography, it could avoid cardiac catheterization in a large number of patients without CAD.

  20. Anomalous origin of the left coronary artery from the pulmonary artery in children: diagnostic use of multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Yao, Qiong; Hu, Xihong [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China)

    2016-09-15

    Anomalous origin of the left coronary artery from the pulmonary artery is a rare congenital anomaly. It is important to demonstrate the anomalous origin of the left coronary artery and its course before surgery. To explore the clinical diagnostic use of multidetector CT coronary angiography in detecting anomalous origin of the left coronary artery from the pulmonary artery in children. Nine children (2 boys, 7 girls) ages 2 months to 9 years with surgically confirmed anomalous origin of the left coronary artery from the pulmonary artery were studied. Clinical data, transthoracic echocardiography and CT coronary angiography images were retrospectively analyzed. Transthoracic echocardiography correctly diagnosed anomalous origin of the left coronary artery from the pulmonary artery in 7 of 9 patients (95% CI: 40-97%). CT coronary angiography revealed the anomalous origin of the left coronary artery in all children (95% CI: 66-100%). In a 4-year-old girl and a 9-year-old girl, CT coronary angiography showed dilation of the right coronary artery and collateral circulation between the right and the left coronary arteries. CT coronary angiography is a useful method to show the anomalous origin of the coronary artery in children with anomalous origin of the left coronary artery from the pulmonary artery, especially for patients in whom origin of the left coronary artery cannot be detected by transthoracic echocardiography. (orig.)

  1. Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.D.; Koesling, S. [University of Halle-Wittenberg, Department of Radiology, Halle Saale (Germany); Mlynski, R. [Head and Neck Surgery ' ' Otto Koerner' ' , Department of Otorhinolaryngology, Rostock (Germany); Plontke, S.K. [University of Halle-Wittenberg, Department of Otorhinolaryngology, Head and Neck Surgery, Halle Saale (Germany)

    2016-12-15

    Modern passive middle ear titanium prostheses are filigree structures, resulting in poorer depiction on CT compared to prostheses used in the past. We compared the visibility of newer prostheses on cone beam CT (CBCT) to multi-detector CT (MDCT) with standard and lower dose in vitro, and analysed image noise and metal artefacts. Six different titanium middle ear prostheses (three partial and one total ossicular replacement prostheses, two stapes prostheses) were implanted twice in formalin-fixed head specimens - first correctly and then with displacement. Imaging was performed using standard CBCT and MDCT as well as MDCT with lower dose (36 single imaging investigations). Images were analysed with knowledge of the used types of middle ear prostheses, but blinded with respect to the positioning in the specific case. On all images the type of prostheses and their positions could be clearly recognized. Their identifiability including their details was rated as statistically significantly higher for all CBCT investigations than for MDCT. MDCT with lower dose showed the worst results. No statistical differences were found in image noise and metal artefacts. If available, CBCT should be preferred over MDCT in diagnostic evaluation of passive middle ear prostheses. (orig.)

  2. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Energy Technology Data Exchange (ETDEWEB)

    Bulakci, Mesut, E-mail: mesutbulakci@yahoo.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Kalelioglu, Tuba, E-mail: tubakarsakarya@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Bulakci, Betul Bozkurt, E-mail: dr.betulbozkurt@gmail.com [Department of Family Medicine, Istanbul University, Istanbul Faculty of Medicine, 34390 Capa, Istanbul (Turkey); Kiris, Adem, E-mail: ademkiris@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey)

    2013-08-15

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing.

  3. Acute aortic syndromes: Role of multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca; Renda, Pietro [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy); Fiore, Davide [Department of Radiology, University of Padova, Padova (Italy); Scaglione, Mariano [Emergency and Trauma CT Section, Department of Radiology, Cardarelli Hospital, Naples (Italy); Piccoli, GianPiero [Cardiosurgery Division, Ospedali Riuniti ' Torrette-Lancisi-Salesi' , Ancona (Italy); Giovagnoni, Andrea [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy)], E-mail: a.giovagnoni@univpm.it

    2008-03-15

    Acute thoracic aortic syndromes encompass a spectrum of emergencies including aortic dissection, intramural haematoma, penetrating atherosclerotic ulcer and aneurysm rupture. All these life-threatening conditions require prompt diagnosis and appropriate management. To date multi-detector row Computed Tomography represents a valuable diagnostic tool especially in the emergency setting. This paper focus on the use of multi-detector row Computed Tomography in the evaluation of acute thoracic aortic syndromes and illustrates the key imaging findings related to each disease.

  4. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Rixe, Johannes; Schmitt, Joern; Neumann, Thomas; Hamm, Christian W.; Rolf, Andreas [Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany); University Hospital of Giessen and Marburg, Site Giessen, Department of Internal Medicine I (Cardiology, Angiology), Giessen (Germany); Schuhbaeck, Annika; Nef, Holger M.; Achenbach, Stephan [University Hospital of Giessen and Marburg, Site Giessen, Department of Internal Medicine I (Cardiology, Angiology), Giessen (Germany); Liebetrau, Christoph; Moellmann, Helge; Szardien, Sebastian; Brandt, Roland [Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany); Schneider, Christian; Krombach, Gabriele [University Hospital of Giessen and Marburg, Department of Radiology, Giessen (Germany)

    2012-12-15

    In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI. A total of 122 patients (67 male, mean age 84 {+-} 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated. Mean eccentricity of the aortic annulus determined by MDCT was 0.34 {+-} 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 {+-} 2.1 mm in MDCT and 24.0 {+-} 2.5 mm in TEE (P < 0.0001 for agreement). Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. (orig.)

  5. Active extravasation of contrast within the hemorrhage (spot sign: a multidetector computed tomography finding that predicts growth and a worse prognosis in non-traumatic intracerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Marcos Rosa Junior

    2013-10-01

    Full Text Available Intracerebral hemorrhage (ICH causes high rates of disability and neurological sequelae Objective To evaluate spot signs as predictors of expansion and worse prognosis in non-traumatic ICH in a Brazilian cohort. Method We used multidetector computed tomography angiography to study 65 consecutive patients (40 men, 61.5%, with ages varying from 33 to 89 years (median age 55 years. Clinical and imaging findings were correlated with the findings based on the initial imaging. Results Of the individuals who presented a spot sign, 73.7% died (in-hospital mortality, whereas in the absence of a spot sign the mortality rate was 43.0%. Although expansion of ICH was detected in 75% of the patients with a spot sign, expansion was observed in only 9.0% of the patients who did not present a spot sign. Conclusions The spot sign strongly predicted expansion in non-traumatic ICH and an increased risk of in-hospital mortality.

  6. Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Yongdong Severance Hospital, Department of Radiology, Seoul (Korea); Ryu, Young Hoon; Hur, Jin; Kim, Sang Jin; Kim, Hyun Soo; Choi, Byoung Wook [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Young; Kim, Hyung Jung [Yonsei University College of Medicine, Department of Pulmonology, Seoul (Korea)

    2005-09-01

    The purposes of this study were to evaluate the right ventricular (RV) volume and mass using cardiac multidetector computed tomography (MDCT) and to compare the cardiac MDCT results with those from first-pass radionuclide angiography (FPRA). Twenty patients were evaluated for the RV end-diastolic volume (RVEDV), the RV end-systolic volume (RVESV), the RV ejection fraction (RVEF), and RV mass using cardiac MDCT with a two-phase reconstruction method based on ECG. The end-diastolic phase was reconstructed at the starting point of the QRS complex on ECG, and the end-systolic phase was reconstructed at the halfway point of the ascending T-wave on ECG. The RV mass was measured for the end-systole. The RVEF was also obtained by FPRA. The mean RVEF (47{+-}7%) measured by cardiac MDCT was well correlated with that (44{+-}6%) measured by FPRA (r=0.854). A significant difference in the mean RVEF was found between cardiac MDCT and FPRA (p=0.001), with an overestimation of 2.9{+-}5.3% by cardiac MDCT versus FPRA. The interobserver variability was 4.4% for the RVEDV, 6.8% for the RVESV, and 7.9% for the RV mass, respectively. Cardiac MDCT is relatively simple and allows the RV volume and mass to be assessed, and the RVEF obtained by cardiac MDCT correlates well with that measured by FPRA. (orig.)

  7. The effectiveness of postmortem multidetector computed tomography in the detection of fatal findings related to cause of non-traumatic death in the emergency department

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Naoya; Higuchi, Takeshi; Shiotani, Motoi [Niigata City General Hospital, Department of Diagnostic Radiology, Niigata, Niigata (Japan); Hirose, Yasuo [Niigata City General Hospital, Department of Emergency and Critical Care, Niigata (Japan); Shibuya, Hiroyuki; Hashidate, Hideki [Niigata City General Hospital, Department of Pathology, Niigata (Japan); Yamanouchi, Haruo; Funayama, Kazuhisa [Niigata University Graduate School of Medical and Dental Sciences, Department of Community Preventive Medicine, Division of Legal Medicine, Niigata (Japan)

    2012-01-15

    To investigate the diagnostic performance of postmortem multidetector computed tomography (PMMDCT) for the detection of fatal findings related to causes of non-traumatic death in the emergency department (ED). 494 consecutive cases of clinically diagnosed non-traumatic death in ED involving PMMDCT were enrolled. The fatal findings were detected on PMMDCT and classified as definite or possible findings. These findings were confirmed by autopsy in 20 cases. The fatal findings were detected in 188 subjects (38.1%) including 122 with definite (24.7%) and 66 with possible finding (13.4%). Definite findings included 21 cases of intracranial vascular lesions, 84 with intra-thoracic haemorrhage, 13 with retroperitoneal haemorrhage and one with oesophagogastric haemorrhage. In three patients who had initially been diagnosed with non-traumatic death, PMMDCT revealed fatal traumatic findings. Two definite findings (two haemopericardiums) and seven possible findings (two intestinal obstructions, one each of multiple liver tumours central pulmonary artery dilatation, pulmonary congestion, peritoneal haematoma, and brain oedema) were confirmed by autopsy. The causes of death were not determined in cases with possible findings without autopsy. PMMDCT is a feasible tool for detecting morphological fatal findings in non-traumatic death in ED. It is important to know the ability and limitation of PMMDCT. (orig.)

  8. Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, Dagmar; Wildberger, Joachim E.; Das, Marco; Hohl, Christian; Mahnken, Andreas H.; Guenther, Rolf W.; Staatz, Gundula [University Hospital RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Barker, Michael [University Hospital RWTH Aachen, Department of Pediatrics, Aachen (Germany)

    2006-08-15

    To evaluate the value of dose-reduced 16-slice multidetector-row spiral computed tomography (16-MDCT) using virtual tracheobronchoscopy (VTB) and virtual bronchography (VBG) in children with suspected tracheobronchial stenosis. 12 children (4 d to 3 years, body weight 1.2 kg to 13.5 kg) with stridor and suspected tracheobronchial stenosis were examined by contrast-enhanced low-dose 16-MDCT. Conventional axial slices, MPRs, VTB, and VBG were calculated. Image findings were correlated with the results of fiberoptic bronchoscopy (12 out of 12) as a gold standard and subsequent surgery (8 out of 12). VTB and VBG demonstrated the fiberoptic bronchoscopically suspected tracheal stenosis in 11 of 12 children due to vascular compression because of the brachiocephalic trunk (6), a double aortic arch (2), a vascular compression of the left main bronchus (2), and a right aberrant subclavian artery (1). Eleven out of 12 stenoses were correctly depicted by conventional axial slices, MPRs, VTB, and VBG. Dose reduction was 79 to 85.8% compared to a standard adult chest CT. Dose-reduced 16-MDCT with the use of VTB and VBG is effective for the evaluation of tracheobronchial stenosis in children and correlates well with fiberoptic bronchoscopy. (orig.)

  9. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  10. Diagnostic value of ECG-gated multidetector computed tomography in the early phase of suspected acute myocarditis. A preliminary comparative study with cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dambrin, Gregoire; Caussin, Christophe; Lancelin, Bernard; Paul, Jean F. [Centre Chirurgical Marie Lannelongue, Departments of Cardiology and Radiology, Le Plessis Robinson (France); Laissy, Jean P.; Serfaty, Jean M. [AP-HP, Hospital Bichat, Department of Radiology, Paris (France)

    2007-02-15

    The aim of the study was to determine the potential diagnostic value of contrast-enhanced echocardiogram (ECG)-gated multidetector computed tomography (MDCT) in the setting of suspected acute myocarditis compared with contrast-enhanced magnetic resonance imaging (MRI). The study group consisted of 12 consecutive patients admitted for suspected acute myocarditis less than 10 days after onset of symptoms. All patients had clinical, electrocardiographic signs, and laboratory findings consistent with the diagnosis. All patients but one (severe claustrophobia) underwent cardiac MRI using T1-weighted delayed-enhancement images after injection of gadolinium. ECG-gated MDCT was performed in all patients and included a first-pass contrast-enhanced acquisition and a delayed acquisition. MRI revealed abnormal focal or multifocal myocardial enhancement and confirmed the diagnosis in 11 patients. The first-pass MDCT acquisition showed homogenous left-ventricle contrast enhancement and absence of coronary stenosis in all patients. Delayed MDCT acquisition, performed 5 min later without reinjection of contrast medium revealed multiple areas of myocardial hyperenhancement in a focal or a multifocal pattern (six and six patients, respectively). Extent and location of hyperenhancement at MDCT correlated well with that observed at MR examination for all 11 patients evaluated by both techniques (r=0.9167, p=0.0004). These preliminary results show that ECG-gated MDCT could be a useful alternative noninvasive diagnostic test in the early phase of acute myocarditis. (orig.)

  11. Comparison of MDCTA (16-slice multi-detector row computed tomography arthrography) and MRA (magnetic resonance arthrography) for detecting labral lesions of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung A; Cha, Jang Gyu; Hong, Hyun Sook; Choi, Deuk Lin; Park, Jai Soung; Lee, Hae Kyung; Kim, Dae Ho [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2007-11-15

    To compare the accuracy of 16-slice multi-detector row computed tomographic arthrography (MDCTA) and magnetic resonance arthrography (MRA) for making the diagnosis and classification of labroligamentous injuries. This study is a prospective series that used MRA and MDCTA to examine 23 patients who complained of shoulder instability. Two radiologists independently analyzed the MRA and MDCTA. The sensitivity, specificity, accuracy, positive and negative predictive values were calculated from the arthrograms and the arthroscopic findings. The images of MDCTA and MRA corresponded with the findings on arthroscopy. Both imaging modalities had the same sensitivity for detecting Bankart lesions (n = 10, 90%) and posterior labral tears (n = 2, 50%) on McNemar test ({rho} = 1.00). For superior labrum anterior-to-posterior (SLAP) lesions, 6 MRA cases and 4 MDCTA cases corresponded with the arthroscopic findings. The difference between the sensitivities of MDCTA (66.7%) and MRA (100%) was not significant ({rho} 0.09). We suggest that the sensitivity of diagnosing labral lesions that induce shoulder instability is similar for MDCTA and MRA. MDCTA is effective for diagnosing and evaluating shoulder instability.

  12. Magnetic Resonance Enterography Findings in Crohn′s disease in the Pediatric Population and Correlation with Fluoroscopic and Multidetector Computed Tomographic Techniques

    Directory of Open Access Journals (Sweden)

    Parul Patel

    2011-01-01

    Full Text Available Traditionally, fluoroscopic examinations such as enteroclysis, upper GI studies, and small bowel follow through exams have been the procedures of choice in evaluating inflammatory bowel disease (IBD in pediatric populations. With the advent of multidetector computed tomography (MDCT, it has subsequently become a complementary examination in imaging inflammatory bowel disease. A major advantage of MDCT over fluoroscopic examination is its ability to directly visualize bowel mucosa, as well as demonstrate extra-enteric complications of IBD such as abscesses, fistulae, and sinus tracts. The major disadvantage of CT however is exposure to ionizing radiation, especially in IBD patients of the pediatric age group who maybe repeatedly imaged due to exacerbations. As a result, magnetic resonance enterography (MRE is becoming increasingly important in the evaluation and follow-up of pediatric patients with IBD. This pictorial essay will summarize the multi-modality imaging findings of IBD with emphasis on MRE including the imaging protocol and procedure. For the purposes of this article, patients less than 17 years of age have been considered to represent the pediatric population.

  13. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  14. A 16-slice multidetector computed tomography protocol for evaluation of the gastroepiploic artery grafts in patients after coronary artery bypass surgery

    Energy Technology Data Exchange (ETDEWEB)

    Dorgelo, J.; Willems, T.P.; Ooijen, P.M.A. van; Oudkerk, M. [University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); Panday, G.F.V.; Boonstra, P.W.; Zijlstra, F. [University Medical Center Groningen, Thoraxcenter, Groningen (Netherlands)

    2005-09-01

    Arterial coronary bypass grafts [internal mammary arteries and gastroepiploic artery (GEA)] are in widespread use for coronary surgery. Since selective catheterisation of the GEA graft to monitor patency, is often unsuccessful, a non-invasive protocol to visualise the GEA-graft from origin to anastomosis is presented using 16-slice multidetector computed tomography (MDCT). Twenty-six male patients (mean age 58.1{+-}6.7 years) with GEA grafts were scanned according to a protocol of an ECG-synchronised cardiac scan followed by a thoracoabdominal scan. To terminate the scan at the correct anatomical level, the lowest level of the GEA was coded based on the lumbar vertebrae level. Scores ranging from one (excellent) to four (bad) were assigned to evaluate visualisation quality of the grafts. GEA grafts were assessable in 62% of the thoracoabdominal scans and 69% of the cardiac scans. On average, the lowest part of the GEA corresponded with a level between L1 and L2, in two cases in the upper part of L3. Mean visualisation score in the thoracoabdominal scans and cardiac scans was good (respectively 1.4{+-}0.6 and 1.4{+-}1.0). Sixteen-slice MDCT is a promising alternative for catheterisation in evaluating patency of GEA grafts, using the presented protocol with thoracoabdominal scan including L3 for complete coverage of the GEA graft. (orig.)

  15. SU-F-207-01: Comparison of Beam Characteristics and Organ Dose From Four Commercial Multidetector Computed Tomography Scanners

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, T; Araki, F [Kumamoto University, Kumamoto, Kumamoto (Japan)

    2015-06-15

    Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chamber and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.

  16. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  17. 经胃镜胃黏膜下注射64排螺旋CT胃周淋巴结造影初探%Lymphatic Drainage from Gastric Tract:Preliminary Investigating Feasibility of Endoscopic 64-row Spiral CT Lymphography

    Institute of Scientific and Technical Information of China (English)

    朱建兵; 陈光强; 李勇; 朱江涛; 张伟; 龚建平

    2012-01-01

    目的 初步探讨胃黏膜下注射64排螺旋CT胃周淋巴结造影的应用价值.方法 征集21例志愿患者,进行胃镜下胃黏膜下造影剂注射,然后进行64排螺旋CT扫描.结果 16例患者均在完成64排螺旋CT的扫描获得相应图像.CT图像显示5例患者可见肝脏及血管旁线性致密影呈现;14例非胃癌患者仅8例发现可辨别的淋巴结影,其中2例患者发现胃周淋巴结密度增高.结论 胃镜辅助下64排螺旋CT胃周淋巴结造影作为一种潜在的术前淋巴结造影的选择具有一定优越性,但是应用于临床需要进一步的研究.%Objective To investigate feasibility of endoscopic 64-row spiral CT lymphography of the gastric tract preliminarily.Methods With institutional committee approval,a total of 2mL of undiluted iopamidol was injected into the gastric submucosa by endoscope in 21 volunteer patients,then scanning with 64-row spiral CT. Result 16 patients completed CT scan and got the imaging needed;5 patients were found the line high attenuation nearby liver and vascular;8 of the 14 patients were found lymphatic nodes identified;2 patients were found high attenuation lymphatic nodes nearby stomach.Conclusion Endoscopic 64-row spiral CT lymphography of stomach as a potentially lymphography of the stomach,still needs more investigation for clinic application.

  18. Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, Fredrik [Lund University, Department of Radiology, Malmoe University Hospital, 205 02, Malmoe (Sweden); Nyman, Ulf [Lund University, Department of Radiology, Lasarettet Trelleborg, 23185, Trelleborg (Sweden)

    2006-05-15

    The aim of this study was to assess the feasibility of minimising contrast-medium (CM) doses using 80-peak kilovoltage (kVp) 16-channel multidetector computed tomography (MDCT) with CM dose tailored to body weight, when diagnosing pulmonary embolism (PE) in azotaemic patients. Twenty-nine patients (68-93 years; 38-79 kg) with an estimated glomerular filtration rate of 12-49 ml/min underwent 80 kVp MDCT at a median dose of 200 mg iodine (I)/kg and 15 s injection time. Pulmonary artery (PA) enhancement where compared with our own reference material using 320 mg I/kg at 120 kVp and with reported figures in the literature at 120-140 kVp and a 42 g iodine CM dose. Median (1st and 3rd quartiles) values regarding CM dose were 12.2 (9.9-12.8) g iodine; density of left main and lower lobe segmental PA 339 (275-395) Hounsfield units (HU) and 354 (321-442) HU, respectively. Those enhancement values were similar to those obtained from the reference population at 120 kVp and those reported in the literature at 120-140 kVp. One patient had a transient increase in plasma creatinine. Three months' follow-up revealed deep venous thrombosis among 1/18 patients with negative results from computed tomography (CT). We conclude that 80 kVp 16-channel MDCT to diagnose PE in azotaemic patients may be performed with markedly reduced CM doses, implying a lesser risk for CM-induced nephropathy. (orig.)

  19. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  20. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    A Chatterjee; Sushil Kamerkar; A K Jethra; S Padmini; M P Diwakar; S S Pande; M D Ghodgaonkar

    2001-07-01

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

  1. Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

    Energy Technology Data Exchange (ETDEWEB)

    Juergens, Kai Uwe; Maintz, David; Heimes, Britta; Fallenberg, Eva Maria; Heindel, Walter; Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Grude, Matthias [University of Muenster, Department of Cardiology and Angiology, Muenster (Germany); Boese, Jan M. [Siemens Medical Solutions, Forchheim (Germany)

    2005-01-01

    A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192{+-}24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139{+-}12, 113{+-}13 and 96{+-}11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9{+-}11.8 ml to 8.1{+-}13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function. (orig.)

  2. Noninvasive Multidetector Computed Tomography Enterography in Patients with Small-Bowel Crohn's Disease: Is a 40-Second Delay Better than 70 Seconds?

    Energy Technology Data Exchange (ETDEWEB)

    Vandenbroucke, F.; Mortele, K.J.; Tatli, S.; Pelsser, V.; Erturk, S.M.; Mey, J. de; Silverman, S.G. (Div. of Abdominal Imaging and Intervention, Dept. of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (US))

    2007-11-15

    Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established. Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography. Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10). Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader. Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material

  3. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  4. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chen Tianwu, E-mail: twchenscu@yahoo.com.cn [Sichuan Province Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637000 (China); Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yang Zhigang, E-mail: yangzg6666@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Dong Zhihui, E-mail: dongzhih@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li Yuan, E-mail: dr.liyuan@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Yao Jin, E-mail: shelleyyao@163.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Wang Qiling, E-mail: xiaohongmao99@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Qian Lingling, E-mail: moneylinglingch1999@126.com [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2011-11-15

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 {+-} 0.49 whereas S/N ratios were 5.21 {+-} 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 {+-} 24.15 ml/min/ml, 24.06 {+-} 9.87 HU, 29.42 {+-} 8.61 s, and 12.45 {+-} 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  5. Diagnostic Sensitivity of Multidetector-Row Spiral Computed Tomography Angiography in the Evaluation of Type-II Endoleaks and their Source: Comparison between Axial Scans and Reformatting Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Pascalis, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G. (Depts. of Radiology and Vascular Surgery, Azienda Ospedaliero-Universitaria di Cagliari, Polo di Monserrato, Monserrato, Cagliari (Italy))

    2008-07-15

    Background: After endovascular stent-graft placement, several complications may occur. Retrograde filling of the aneurysm (type-II endoleak) is the most common. Purpose: To evaluate the accuracy, image quality, and interobserver agreement of multidetector-row spiral computed tomography angiography (MDCTA) in the diagnosis of type-II endoleak, by using various types of reformatting techniques in comparison to regular axial images. Material and Methods: Twenty-four patients who had had endovascular repair of an infrarenal abdominal aortic aneurysm with stent graft were retrospectively studied. In 12 of 24 patients, a type-II endoleak was found. CT scans were obtained after intravenous administration of 130 ml of nonionic contrast material using a 4-6-ml/s flow rate. All patients were investigated with axial scans, multiplanar reconstruction (MPR), maximum intensity projection (MIP), shaded-surface display (SSD), and volume-rendering (VR) techniques. For each patient and for each reconstruction method, the image quality of the scans was scored as 0 for bad quality, 1 for poor quality, 2 for good quality, and 3 for excellent quality images. Two radiologists reviewed the CT images independently. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each reconstruction method, with the axial images as the reference method. Interobserver agreement and kappa value were also recorded. Results: MPR showed the highest sensitivity (83% and 67% for observers 1 and 2, respectively), PPV (91% and 80% for observers 1 and 2, respectively), and NPV (85% and 71% for observers 1 and 2, respectively), whereas VR showed the highest specificity (92% for both observer 1 and 2). Conclusion: Reformatting techniques provide good-quality images; nevertheless, their efficacy in the study of type-II endoleak was found to be suboptimal in comparison to regular axial images. The MPR technique is probably the best choice in conjunction

  6. Role of multiphasic multi-detector computed tomography (MDCT in the diagnosis and staging of solid neoplastic renal masses

    Directory of Open Access Journals (Sweden)

    Manal H. Wahba

    2015-03-01

    Conclusion: Multiphase multislice computed tomography combined with CT angiography and CT urography have a major role in solid renal neoplastic masses’ diagnosis, characterization and differentiating benign and malignant tumors.

  7. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel [University Duesseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Duesseldorf (Germany); Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael [University Duesseldorf, Medical Faculty, Department of Traumatology and Hand Surgery, Duesseldorf (Germany); Hakimi, Ahmad R. [Universtity Duesseldorf, Medical Faculty, Department of Oral Surgery, Duesseldorf (Germany)

    2012-05-15

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 {+-} 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  8. Cuatro años de experiencia en el uso de tomografía computada multidetector en el trasplante de páncreas: aprendiendo junto a los cirujanos Four years of experience in the use of multidetector computer tomography in pancreas transplantation: a lesson learned together with surgeons

    Directory of Open Access Journals (Sweden)

    Hugo José Paladini

    2013-03-01

    .Purpose. To gain knowledge of normal postoperative findings on Multidetector Computed Tomography (MDCT in patients with pancreas transplant and describe the most frequent complications. Topic review. Pancreatic transplantation is currently the only definitive treatment for diabetic patients. In recent years, its use has increased as therapeutic strategy. According to the INCUCAI, in 2001 9 transplants were performed, increasing to 74 in 2011. This increase creates a need for radiologists to gain knowledge of the normal postoperative anatomy and learn to identify the most frequent postoperative complications. The imaging methods used are Doppler / ultrasound, MDCT, conventional angiography and MRI. In patients with good renal function in whom ultrasound is not diagnostic for characterization of complications, the next step is MDCT. At our hospital, 25 pancreatic transplants were performed in 2008-2012. Postoperative complications were suspected clinically or by ultrasound in 19 of them. Fifteen of them were evaluated by CT for further characterization Imaging findings or procedure details. As we learn the surgical techniques that were performed, normal images are described, allowing a correct interpretation of MDCT findings in these patients. The most common post operative complications were: - Vascular: thrombosis, arteriovenous fistula, pseudoaneurysm - Non vascular: pancreatitis, pancreatic fistulas, collections, pneumoperitoneum, ileus. Conclusion: MDCT is a useful method for assessing patients with pancreas transplantation. A clear understanding of the unique anatomy and possible postoperative complications is crucial for the radiologist to guide the monitoring and treatment of this patient.

  9. Detection of non-ST-elevation myocardial infarction and unstable angina in the acute setting: meta-analysis of diagnostic performance of multi-detector computed tomographic angiography

    Directory of Open Access Journals (Sweden)

    Sarno Giovanna

    2007-12-01

    Full Text Available Abstract Background Multi-detector computed tomography angiography (MDCTA has been increasingly used in the evaluation of the coronary arteries. The purpose of this study was to review the literature on the diagnostic performance of MDCTA in the acute setting, for the detection of non-ST-elevation myocardial infarction (NSTEMI and unstable angina pectoris (UAP. Methods A Pubmed and manual search of the literature published between January 2000 and June 2007 was performed. Studies were included that compared MDCTA with clinical outcome and/or CA in patients with acute chest pain, presenting at the emergency department. More specifically, studies that only included patients with initially negative cardiac enzymes suspected of having NSTEMI or UAP were included. Summary estimates of diagnostic odds ratio (DOR, sensitivity and specificity, negative (NLR and positive likelihood ratio (PLR were calculated on a patient basis. Random-effects models and summary receiver operating curve (SROC analysis were used to assess the diagnostic performance of MDCTA with 4 detectors or more. The proportion of non assessable scans (NAP on MDCTA was also evaluated. In addition, the influence of study characteristics of each study on diagnostic performance and NAP was investigated with multivariable logistic regression. Results Nine studies totalling 566 patients, were included in the meta-analysis: one randomised trial and eight prospective cohort studies. Five studies on 64-detector MDCTA and 4 studies on MDCTA with less than 64 detectors were included (32 detectors n = 1, 16 detectors n = 2, 16 and 4 detectors n = 1. Pooled DOR was 131.81 (95%CI, 50.90–341.31. The pooled sensitivity and specificity were 0.95 (95%CI, 0.90–0.98 and 0.90 (95%CI, 0.87–0.93. The pooled NLR and PLR were 0.12 (95%CI, 0.06–0.21 and 8,60 (95%CI, 5.03–14,69. The results of the logistic regressions showed that none of the investigated variables had influence on the diagnostic

  10. Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies

    Institute of Scientific and Technical Information of China (English)

    Maythem; Saeed; Steven; W; Hetts; Robert; Jablonowski; Mark; W; Wilson

    2014-01-01

    Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume(ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular(approximately 10% of tissue volume), interstitium(approximately 15%) and intracellular(approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types Ⅰ/Ⅲ collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis(e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy(hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging(MRI) has the ability to characterize tissue proton relaxation times(T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI(DE-MRI) and multi-detector computed tomography(DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary catheterization and

  11. Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Katharina [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)]. E-mail: katharina.anders@idr.imed.uni-erlangen.de; Baum, Ulrich [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Michael [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Ropers, Dieter [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Schmid, Axel [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Pohle, Karsten [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Daniel, Werner G. [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Bautz, Werner [Department of Radiology, Friedrich-Alexander University of Erlangen-Nuremberg (Germany); Achenbach, Stephan [Department of Internal Medicine II, Friedrich-Alexander University of Erlangen-Nuremberg (Germany)

    2006-03-15

    Purpose: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. Materials and methods: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses {>=}50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. Results: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis {>=}50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic 'negative' graft-CTA. According to

  12. Relevant incidental findings at abdominal multi-detector contrast-enhanced computed tomography:A collateral screening?

    Institute of Scientific and Technical Information of China (English)

    Luca; Maria; Sconfienza; Giovanni; Mauri; Claudia; Muzzupappa; Alessandro; Poloni; Michele; Bandirali; Anastassia; Esseridou; Stefania; Tritella; Francesco; Secchi; Giovanni; Di; Leo; Francesco; Sardanelli

    2015-01-01

    AIM: To investigate the prevalence of relevant incidental findings(RIFs) detected during routine abdominal contrast-enhanced computed tomography(Ce CT).METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal Ce CT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs(if needing additional workup) was noted.RESULTS: One thousand forty abdominal Ce CT were performed in 949 patients(528 males, mean age 66 ±14 years). No significant difference was found between inpatients and outpatients age and sex distribution(P > 0.472). RIFs were found in 195/1040(18.8%) Ce CT [inpatients = 108/470(23.0%); outpatients = 87/570(15.2%); P = 0.002]. RIFs were found in 30/440(6.8%) Ce CT with a previous exam and in 165/600(27.5%) without a previous exam(P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different(P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs.CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal Ce CT. Risk of overdiagnosis should be taken into account.

  13. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Manson, David E. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Compton, Gregory [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Epworth Hospital, Epworth Medical Imaging, Richmond, VIC (Australia); Humpl, Tilman [University of Toronto, Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON (Canada)

    2016-09-15

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  14. Application of 64-row spiral CT in the evaluation of invasion of trachea,bronchi,and hilar vessels in central type of lung cancer%MSCT在判断中央型肺癌对气管、支气管及肺门血管侵犯中的价值

    Institute of Scientific and Technical Information of China (English)

    黄宝泉; 郑悦; 张庆武; 曾向廷; 林惠如

    2013-01-01

    Objective: To investigate the value of 64 row spiral computed tomography (MSCT) in the diagnosis of tra chea,bronchi and hilar vascular invasion by central type of lung cancer (CLC). Methods:Seventy five cases of CLC under went MSCT examination with post processing techniques including multiplanar reformation (MPR) ,curved planar reforma tion (CPR) ,volume rendering (VR) ,minimum intensity projection (MinIP) ,maximum intensity projection (MIP) and CT virtual endoscopy (CTVE). The relationship of trachea,bronchi,pulmonary hilar vessels with the neoplasm was studied. Results :Invasion of trachea and bronchi by CLC included extraluminal compression type (38 cases,50. 7%) ,which was showed on CT as compression and/or invasion of bronchi led to uneven stenosis;infiltration of bronchial wall(28 cases,37.3%)12. 0%) showed as protruding of neoplasm into the lumen which led to eccentric stenosis of trachea/bronchi. Altogether 117 hilar vessels were invaded by CLC,of which,95 (81. 2%) could be assessed on CT,showing obvious narrowing or oblitera tion; blood vessels encircled by tumor (n = 12,10. 3%) , and tumor thrombosis (n=10,8. 5%). Conclusion: The anatomic features of trachea,bronchi,and hilar vessels and their spacial relationship with CLC could be accurately assessed on 64 row spiral CT with post processing techniques, which provides significant information in judging whether there are trachea, bronchi, and hilar vessel invasion by CLC.%目的:探讨64排螺旋CT及后处理技术在判断中央型肺癌(CLC)对气管、支气管及肺门血管侵犯中的价值.方法:75例经纤支镜或病理确诊的CLC患者行64排螺旋CT扫描,运用多平面重组、曲面重组、容积再现、最大密度投影、CT仿真内窥镜等后处理技术观察肿瘤与气管、支气管及肺门血管的关系.结果:肿瘤对气管、支气管的侵犯表现为管外压迫型38例(50.7%),CT表现为肿瘤压迫并侵犯支气管,管腔内呈不均匀狭窄;管壁浸润型(28

  15. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  16. Diagnosis and Treatment Value of 64 Row CT in Children With Secretory Otitis Media%64排CT在儿童分泌性中耳炎诊疗中的作用

    Institute of Scientific and Technical Information of China (English)

    付高尚; 徐艳霞; 韩富根

    2015-01-01

    目的:探讨64排CT在儿童分泌性中耳炎诊断、治疗过程中的意义。方法对2012年8月~2014年8月在本院治疗的76例(131耳)分泌性中耳炎患儿的临床资料进行回顾性分析。结果76例(131耳)分泌性中耳炎患儿当中,其中部分患儿3月后复查CT乳突密度影降低,避免了不必要的手术。结论64排颞骨CT检查对儿童分泌性中耳炎病情严重程度准确诊断提供重要的参考价值。%Objective To investigate the 64 slice CT in the diagnosis of children with secretory otitis media,in the course of treatment significance.Methods From August 2012 to August 2014 in our hospital(76 cases(131 ears)of secretory otitis media in children with clinical data were retrospectively analyzed.Results 76 cases(131 ears)with secretory otitis media in children,including review of CT significantly decreased the mastoid density in march part of the children,to avoid unnecessary operation.Conclusion The diagnostic accuracy of 64 row CT scanning of temporal bone of children with secretory otitis media disease severity and provides an important reference value.

  17. Comparison of the radiation dose from cone beam computed tomography and multidetector computed tomography in examinations of the hand; Vergleich der Strahlendosis von Cone-Beam Computertomografie und Multidetektor Computertomografie in Untersuchungen der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, J.; Neubauer, C.; Gerstmair, A.; Krauss, T.; Kotter, E.; Langer, M. [University Medical Center Freiburg (Germany). Dept. of Radiology; Reising, K. [University Medical Center Freiburg (Germany). Dept. of Orthopedics and Trauma Surgery; Zajonc, H. [University Medical Center Freiburg (Germany). Dept. of Plastic and Hand Surgery; Fiebich, M.; Voigt, J. [University of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection

    2016-05-15

    Comparison of radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in examinations of the hand. Dose calculations were carried out by means of Monte Carlo simulations in MDCT and CBCT. A corpse hand was examined in a 320-row MDCT scanner and a dedicated extremities CBCT scanner with standard protocols and multiple low-dose protocols. The image quality of the examinations was evaluated by 5 investigators using a Likert scale from 1 (very good) to 5 (very poor) regarding depiction of cortical bone, cancellous bone, joint surfaces, soft tissues and artifacts. For a sum of ratings of all structures < 50 a good overall image quality was expected. The studies with at least good overall image quality were compared with respect to the dose. The dose of the standard examination was 13.21 (12.96 to 13.46 CI) mGy in MDCT and 7.15 (6.99 to 7.30 CI) mGy in CBCT. The lowest dose in a study with good overall image quality was 4.54 (4.43 to 4.64 CI) mGy in MDCT and 5.72 (5.59 to 5.85 CI) mGy in CBCT. Although the dose of the standard protocols in the CBCT is lower than in the MDCT, the MDCT can realize a good overall image quality at a lower dose than the CBCT. Dose optimization of CT examination protocols for the hand is useful in both modalities, the MDCT has an even greater potential for optimization.

  18. A multidetector scintillation camera with 254 channels

    DEFF Research Database (Denmark)

    Sveinsdottir, E; Larsen, B; Rommer, P

    1977-01-01

    A computer-based scintillation camera has been designed for both dynamic and static radionuclide studies. The detecting head has 254 independent sodium iodide crystals, each with a photomultiplier and amplifier. In dynamic measurements simultaneous events can be recorded, and 1 million total counts...... per second can be accommodated with less than 0.5% loss in any one channel. This corresponds to a calculated deadtime of 5 nsec. The multidetector camera is being used for 133Xe dynamic studies of regional cerebral blood flow in man and for 99mTc and 197 Hg static imaging of the brain....

  19. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Energy Technology Data Exchange (ETDEWEB)

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  20. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Science.gov (United States)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  1. Assessment of Cerebral Hemodynamics by 64-Row VCT Perfusion Imaging in Patients with Moya-Moya Disease%64排VCT脑灌注成像对烟雾病的血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    谢安明; 丁耀军

    2014-01-01

    Objective To investigate the changes in cerebral hemodynamics (cerebral blood flow volume,blood capacity,mean transit time and time to peak)using 64-row VCT perfusion im-aging,and to provide imaging evidence for clinical intervention.Methods Thirty patients with moya-moya disease aged 13-49 years (average age 33.8 years,14 males,16 females)were recruited in this study.Cerebral perfusion imaging was performed using a GE LightSpeed VCT scanner at a rate of 5 mL/second and a dose of 50 mL.The scan delay time was 5 seconds and scan time was 45 seconds.Post-processing was conducted with Perfusion 4 software to analyze cerebral blood flow volume,blood capacity,mean transit time and time to peak.Results Of the 30 patients,9 had is-chemic type moya-moya disease and 21 had hemorrhagic type moya-moya disease.The 64-row VCT perfusion imaging showed increased regional cerebral blood flow in 3 patients,decreased re-gional cerebral blood flow in 5,increased regional cerebral blood volume in 3,normal cerebral blood volume in 27,shortened mean transit time and time to peak in 3,and prolonged mean transit time and time to peak in 8.Conclusion Most patients with ischemic type moya-moya disease are characterized by regional hypoperfusion,while patients with hemorrhagic type moya-moya disease are characterized by normal or regional hyperperfusion.The mean transit time and time to peakare sensitive indicators of changes in cerebral hemodynamics.%目的:通过对烟雾病患者进行64排VCT脑灌注成像,了解其脑血流动力学变化情况,包括脑血流量、脑血容量、平均通过时间及达峰时间,为临床干预治疗提供影像学依据。方法30例烟雾病患者,男性14例,女性16例,年龄最大为49岁,最小为13岁,平均年龄为33.8岁。利用 GE公司生产的 LightSpeed VCT螺旋扫描机对烟雾病患者进行灌注扫描,速率5 mL·s-1、剂量50 mL、扫描延迟5 s、扫描时间45 s,然后用该公司配备的 Perfu-sion4

  2. The utility of multi-detector computed tomography in the diagnosis of malignant pleural effusion in the patients with ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Won [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Choi, Hyuck Jae, E-mail: hjchoi@ncc.re.k [Department of Radiology, Asan Medical Center, University of Ulsan, Seoul (Korea, Republic of); Kang, Sokbom; Park, Sang-Yoon; Jung, Dae Chul [Research Institute and Hospital, National Cancer Center (Korea, Republic of); Cho, Jeong Yeon [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Kyung-Sik [Department of Radiology, Asan Medical Center, University of Ulsan, Seoul (Korea, Republic of); Kim, Seung Hyup [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    Purpose: The purpose of this study was to retrospectively assess possible clinical predictors of malignant pleural effusion in patients with ovarian cancer. Materials and methods: This review was performed on 38 ovarian cancer patients that showed pleural effusion in a CT scan and who underwent thoracocentesis before treatment. CT scans were obtained using a 4-channel multi-detector CT scanner. Fisher's exact test was used to determine the probability of malignant pleural effusion as a function of; amount of ascites, lymph node enlargement, amount of pleural effusion, pleural nodules, and pleural thickening. Results: Sixteen (42.1%) of the 38 patients had malignant pleural effusion and malignant pleural effusion amounts were greater than those with nonmalignant effusion. Pleural nodules were more frequently found in the malignant pleural effusion group (eight [50%] patients) than in the nonmalignant group (zero [0%] patient) (p < 0.001). Supradiaphragmatic lymph node enlargement (with short axis diameter 1 cm or more) was more frequent in malignant group (12 [75%] patients) than in the nonmalignant group (two [9.1%] patients) (p < 0.001). Conclusion: The probability of malignant pleural effusion in patients with ovarian cancer was found to be correlated with the amount of pleural effusion, the presence of pleural nodules, and supradiaphragmatic lymph node enlargement.

  3. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging.

    Science.gov (United States)

    Belge, Bénédicte; Coche, Emmanuel; Pasquet, Agnès; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2006-07-01

    Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134+/-51 and 67+/-56 ml) were similar to those by MR (137+/-57 and 70+/-60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55+/-21 vs. 56+/-21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3+/-1.8 vs. 8.8+/-1.9 mm and 12.7+/-3.4 vs. 13.3+/-3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54+/-30 vs. 51+/-31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR.

  4. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography. Comparison with cine magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Belge, Benedicte; Pasquet, Agnes; Vanoverschelde, Jean-Louis J. [Universite Catholique de Louvain, Division of Cardiology, Brussels (Belgium); Coche, Emmanuel [Universite Catholique de Louvain, Division of Radiology, Brussels (Belgium); Gerber, Bernhard L. [Universite Catholique de Louvain, Division of Cardiology, Brussels (Belgium); Cliniques Universitaires St. Luc UCL, Department of Cardiology, Woluwe St. Lambert (Belgium)

    2006-07-15

    Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134{+-}51 and 67{+-}56 ml) were similar to those by MR (137{+-}57 and 70{+-}60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55{+-}21 vs. 56{+-}21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3{+-}1.8 vs. 8.8{+-}1.9 mm and 12.7{+-}3.4 vs. 13.3{+-}3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54{+-}30 vs. 51{+-}31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR. (orig.)

  5. Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Tri-Linh C.; Rizzo, Elena [University Hospital Lausanne (CHUV), Department of Radiology, Lausanne (Switzerland); Huber, Christoph H.; Segesser, Ludwig K. von [University Hospital Lausanne (CHUV), Department of Cardiovascular Surgery, Lausanne (Switzerland); Dehmeshki, Jashmid [Kingston University, Digital Imaging Research Centre, Faculty of Computing, Information Systems and Mathematics, London (United Kingdom); Qanadli, Salah D. [University Hospital Lausanne (CHUV), Department of Radiology, Lausanne (Switzerland)]|[BH-07, Centre Hospitalier Universitaire Vaudois, Service de Radiodiagnostic et de Radiologie interventionnelle, Lausanne (Switzerland)

    2009-03-15

    The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3{+-}3.4, coronary sinus 34.2{+-}4.1, sino-tubular junction 29.7{+-}3.4 and mid ascending aorta 32.7{+-}3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6{+-}11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1{+-}3.7, and between both coronary ostia 7.2{+-}3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9{+-}9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6{+-}3.3, CV 13-43%. Mean aortic valve area was 582.0{+-}131.9 mm{sup 2}. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered. (orig.)

  6. Computed tomography angiography of carotid and coronary artery via a single-bolus injection protocol: a feasibility study using 320-row multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, WeiGuo [The First Affiliated Hospital of Soochow University, Department of Radiology, SuZhou (China); Fudan University, Department of Radiology, Zhongshan Hospital, Shanghai (China); Jin, Hang; Chen, Gang; Chen, Wenfang; Gu, Junying; Zeng, Mengsu [Fudan University, Department of Radiology, Zhongshan Hospital, Shanghai (China)

    2014-07-15

    To investigate the feasibility of using a single-dose injection protocol in CT angiography (CTA) of the carotid and coronary artery with 320-row multidetector CT. A total of 82 consecutive patients with suspected carotid artery disease underwent an original CTA protocol aiming at capturing the extra-cranial carotid arteries and coronary arteries simultaneously using 320-row MDCT. The image quality, attenuation, and CNRs of the carotid and coronary arteries were assessed. The lag time (between two separated volumetric acquisitions) was compared between patients with and without cardiac venous opacification (CVO). The contrast medium volume and radiation dose were recorded. The image quality was 99.4 % diagnostic in carotid and 86.9 % in coronary artery segments. The mean attenuation of carotid and coronary arteries ranged from 462.2 Hu to 533.7 Hu, 415.9 Hu to 454.7 Hu respectively. The mean CNR of the carotid and coronary artery ranged from 15.8 to 18.9 and 17.7 to 20.4 respectively. The lag time in patients with and without CVO was 5.75 ± 1.64 s vs. 4.21 ± 1.14 s (p < 0.05). The mean radiation dose was 6.6 ± 4.1 mSv.The mean contrast media volume was 71.9 ± 9.1 ml. The carotid and coronary artery can be imaged simultaneously via our original single-dose injection CTA protocol using 320-row CT with adequate image quality. (orig.)

  7. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  8. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  9. Research Status Quo of Perfusion Imaging with Multidetector Row Computed Tomography on Esophageal Cancer%食管癌多层螺旋CT灌注成像研究现状

    Institute of Scientific and Technical Information of China (English)

    陈天武; 董志辉

    2011-01-01

    食管癌是常见的恶性肿瘤之一.多层螺旋CT 灌注成像作为一种无创手段,可以在活体状态下评价其微循环.近年来,CT 灌注成像在食管癌的微循环评价、放化疗的疗效判断方面取得进展.本文着重综述多层螺旋CT灌注成像技术在食管癌中的应用研究现状.%Esophageal cancer is one of frequent malignant tumors worldwide. As a noninvasive technique. computed tomography (CT) perfusion imaging could be valuable to assess the microcirculation of esophageal cancer in uivo.Recently, multidetector row CT ( MDCT) perfusion imaging has sparked new interest in the assessment of the microcirculation of esophageal cancer, and therapeutic effects of chemoradiotherapy on this tumor. In this paper, we reviewed the status quo of perfusion imaging with MDCT on esophageal cancer.

  10. Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Storto, Maria Luigia; Maddestra, Nicola; Bonomo, Lorenzo [Department of Clinical Sciences and Bioimaging, Section of Radiology, University ' ' G. d' Annunzio' ' , Ospedale ' ' SS. Annunziata' ' , Via dei Vestini, 66100, Chieti (Italy)

    2004-08-01

    The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4 x 2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate {<=}70 bpm in all patients. The ECG-synchronized axial images, reconstructed in the mid-diastole, MPR, MIP and 3D-VR images were independently and blindly assessed by two radiologists for graft patency and presence of high grade stenosis. Conventional angiography was the standard of reference. MDCT correctly classified 92/94 patent grafts and 26/28 occluded grafts (sensitivity/specificity 93%/97.8%); sensitivity and specificity of MDCT for assessment of arterial grafts were 100 and 98.7% (77/78 patent grafts and 17/17 occluded grafts). Image quality was considered adequate for assessment of significant stenoses in 62/92 (67%) patent grafts, with a significant differences between LIMA and non-LIMA conduits (44/57 vs. 18/65; P=0.002), according to the coronary vessel area supplied (anterior>lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good (K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation

  11. 64 row CT cerebral perfusion applied research of brain ischemia%64排CT脑灌注对脑组织缺血程度的应用研究

    Institute of Scientific and Technical Information of China (English)

    刘贯清; 肖新兰; 李晓; 黄小宁; 李五根

    2015-01-01

    Objective Application of 64 row CT cerebral perfusion brain tissue ischemia. Methods 40 cases of clinical diag-nosis of acute cerebral infarction,patients with unilateral lobe brain perfusion CT perfusion showed abnormal,in combination with MRI to determine infarct,according to the cerebral blood flow group,group A (low perfusion group) and group B (infarction group), respectively,evaluation of two groups of cerebral blood flow perfusion parameters and comparison analysis. Results Of 40 cases, 18 cases of group A,CTP anomaly low perfusion of figure is determined by MTT extend approximately 1.28 (R),decreased CBF mild,CBV basic no change Or moderately reduced,only determined by MTT extension was statistically significant (P<0.01);Infarc-tion group,22 cases of group B,infarction area surrounding IP abnormal perfusion is determined by MTT extend approximately 1. 48(R),CBF significantly decreased approximately 0.45(R),CBV moderately reduced,which extended determined by MTT was sta-tistically significant (P<0.001),decrease CBF was statistically significant (P<0.01);Infarction district performance is determined by MTT extend approximately 1.64(R),CBF significantly decreased approximately 0.36(R),significantly lower CBV (approximately 0. 37)R. Which determined by MTT extension was statistically significant (P<0.001),CBF decline was statistically significant(P<0.01). Conclusion Brain tissue hypoperfusion area with the infarction in central and peripheral IP area the perfusion parameters have significant differences,according to the variation of perfusion parameters characteristics can make the image on the degree of is-chemic infarction assessment,when rCBF<0.5,suggesting infarction risk is extremely high,the clinical guidance for early interven-tion treatment.%目的:探讨应用64排CT脑灌注评价脑组织缺血程度。方法40例临床诊断急性脑梗塞,CT灌注显示单侧脑叶灌注异常患者,结合MRI判断梗塞,根据脑血流量进行分组,A

  12. Advances in multidetector CT diagnosis of pediatric pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Thacker, Paul G. [Dept. of Radiology and Radiological Science, Medical University of South Carolina, Charleston (United States); Lee, Edward Y. [Divi. of Thoracic Imaging, Dept. of Radiology and Medicine, Pulmonary Division Boston Children' s Hospital, Harvard Medical School, Boston (United States)

    2016-04-15

    Although pediatric pulmonary thromboembolism is historically believed to be rare with relatively little information available in the medical literature regarding its imaging evaluation, it is more common than previously thought. Thus, it is imperative for radiologists to be aware of the most recent advances in its imaging information, particularly multidetector computed tomography (MDCT), the imaging modality of choice in the pediatric population. The overarching goal of this article is to review the most recent updates on MDCT diagnosis of pediatric pulmonary thromboembolism.

  13. Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moon Chan [Dept. of Diagnostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2009-09-15

    To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation (0.625 mm x 64 ea), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of 40-80% of R-R interval and 120 mA (80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with

  14. Reproducibility of coronary atherosclerotic plaque characteristics in populations with low, intermediate, and high prevalence of coronary artery disease by multidetector computer tomography: a guide to reliable visual coronary plaque assessments.

    Science.gov (United States)

    de Knegt, Martina C; Linde, Jesper J; Fuchs, Andreas; Nordestgaard, Børge G; Køber, Lars V; Hove, Jens D; Kofoed, Klaus F

    2016-10-01

    To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics. 150 patients, 50 asymptomatic subjects from the general population (low CAD prevalence), 50 symptomatic non-acute coronary syndrome (non-ACS) patients (intermediate CAD prevalence), and 50 ACS patients (high CAD prevalence), matched according to age and gender, were retrospectively enrolled. All coronary segments were evaluated for overall image quality, evaluability, presence of CAD, coronary stenosis, plaque composition, plaque focality, and spotty calcification by four readers. Interobserver agreement was assessed using Fleiss' Kappa (κ) and intra-class correlation (ICC). Widely used clinical parameters (overall scan quality, presence of CAD, and determination of coronary stenosis) showed good agreement among the four readers, (ICC = 0.66, κ = 0.73, ICC = 0.74, respectively). When accounting for heart rate, body mass index, plaque location, and coronary stenosis above/below 50 %, interobserver agreement for plaque composition, presence of CAD, and coronary stenosis improved to either good or excellent, (κ = 0.61, κ = 0.81, ICC = 0.78, respectively). Spotty calcification was the least reproducible parameter investigated (κ = 0.33). Across subpopulations, reproducibility of coronary plaque characteristics generally decreased with increasing CAD prevalence except for plaque composition, (limits of agreement: ±2.03, ±1.96, ±1.79 for low, intermediate and high CAD prevalence, respectively). 320-slice MDCT can be used to assess coronary plaque characteristics, except for spotty calcification. Reproducibility estimates are influenced by heart rate, body size, plaque location, and degree of luminal stenosis.

  15. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome. A comparative study with intravascular ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Iriart, Xavier; Dos-Santos, Pierre [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Brunot, Sebastien [CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France); Coste, Pierre; Leroux, Lionel [Universite Bordeaux 2, Inserm U. 441 Atherosclerose, Bordeaux (France); Unite de Soins Intensifs Cardiologiques, Pessac (France); Montaudon, Michel [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Labeque, Jean-Noel; Jais, Catherine [Unite de Soins Intensifs Cardiologiques, Pessac (France); Laurent, Francois [Universite Bordeaux 2, Inserm U. 885 F 33076, Bordeaux (France); CHU de Bordeaux, Hopital du Haut-Leveque, Unite d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Unite d' Imagerie Thoracique et Cardiovasculaire, Hopital Cardiologique, Pessac (France)

    2007-10-15

    We compared 16-slice computed tomography (CT) with intravascular ultrasound (IVUS) in their ability to identify the culprit lesion, and to assess plaque characterization and vascular remodelling in acute coronary syndrome (ACS). Twenty patients were prospectively studied. Coronary plaque identification and characterization were compared using 16-slice CT and 40-MHz catheter-based IVUS. Minimum lumen area (MLA), cross-sectional vessel area (CVA) and vessel remodelling were determined for each comparable lesion. One hundred and sixty-nine segments were compared and 84 plaques analysed. Sixteen-slice CT detected 95% of culprit lesions (19/20). No feature suggestive of plaque rupture was detected by 16-slice CT. Attenuation measurements within all lesions revealed different values for hypoechoic (38 {+-} 33 HU), hyperechoic (94 {+-} 44 HU), and calcified plaques (561 {+-} 216 HU), (P < 0.001). Agreement between 16-slice CT and IVUS on measuring MLA and CVA was evaluated using Bland-Altman analysis. Pearson and intra-class coefficient (ICC) were 0.81 and 0.70 for MLA, and 0.81 and 0.36 for CVA, for 16-slice CT and IVUS, respectively. Agreement between both techniques for vessel positive remodelling was moderate (kappa = 0.54, P < 0.001). Sixteen-slice CT has shown moderate accuracy in quantifying and characterizing coronary plaques compared with IVUS. Spatial resolution of 16-slice CT remains a major limitation, however, to accurately assess the complex lesions involved in ACS. (orig.)

  16. MULTIDETECTOR COMPUTED TOMOGRAPHIC AND LOW-FIELD MAGNETIC RESONANCE IMAGING ANATOMY OF THE QUADRIGEMINAL CISTERN AND CHARACTERIZATION OF SUPRACOLLICULAR FLUID ACCUMULATIONS IN DOGS.

    Science.gov (United States)

    Bertolini, G; Ricciardi, M; Caldin, M

    2016-05-01

    Focal fluid accumulations in the supracollicular region are commonly termed quadrigeminal cysts and may be either subclinical or associated with neurologic deficits in dogs. Little published information is available on normal imaging anatomy and anatomic relationships for the canine quadrigeminal cistern. Objectives of this observational, cross-sectional study were to describe normal quadrigeminal cistern anatomy and determine the prevalence and characteristics of supracollicular fluid accumulations in dogs. Normal descriptions were accomplished using computed tomographic (CT) cisternography in one canine cadaver, and CT and magnetic resonance imaging (MRI) studies of the brain in four prospectively recruited dogs with no evidence of intracranial disease. Prevalence and characteristics descriptions were accomplished using a retrospective review of brain CT or MRI studies performed during the period of 2005-2015. The normal quadrigeminal cistern consistently exhibited a complex H shape and was separated from the third ventricle by a thin membrane. Prevalence of supracollicular fluid accumulations (SFAs) was 2.19% among CT studies (n = 4427) and 2.2% among MRI studies (n = 626). Dogs with SFA were significantly younger than control dogs (P dogs were predisposed (P dogs with SFAs, the following three patterns were defined: (1) third ventricle (49.54%), (2) quadrigeminal cistern (13.51%), and (3) both third ventricle and quadrigeminal cistern (36.93%). Authors recommend that the term supracollicular fluid accumulation (SFA) should be used rather than the term quadrigeminal cyst to describe these focal fluid accumulations in dogs.

  17. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  18. Efficacy of pre-scan beta-blockade and impact of heart rate on image quality in patients undergoing coronary multidetector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, Michael D. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Pena, Antonio J.; Nichols, John H. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Worrell, Stewart [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Bamberg, Fabian [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Dannemann, Nina [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Abbara, Suhny; Cury, Ricardo C.; Brady, Thomas J. [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Hoffmann, Udo [Cardiac MR PET CT Program, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston MA (United States)], E-mail: uhoffmann@partners.org

    2008-04-15

    Objective: While beta-blockers are routinely administered to patients prior to coronary computed tomography angiography (CTA), their effectiveness is unknown. We therefore assessed the efficacy of beta-blockade with regards to heart rate (HR) control and image quality in an unselected patient cohort. Methods: We studied 150 consecutive patients (104 men/46 female; mean age, 56 {+-} 13 years) referred for coronary CTA. Intravenous metoprolol (5-20 mg) was administered to patients with a HR >65 beats per minute (bpm). The goal HR was defined as an average HR <65 bpm without a single measurement above 68 bpm. Results: Overall, 45% (68/150) of patients met the HR criteria for beta-blocker administration of which 76% (52/68) received metoprolol (mean dose 12 {+-} 10 mg). Of the 52 patients who received beta-blocker versus the 98 who did not, 18 (35%) versus 62 (64%) patients achieved the goal HR, respectively. All patients who achieved the target HR had an evaluable CTA while five patients who did not achieve the target HR had at least one non-evaluable coronary artery due to motion artifact. There was also a significant reduction in any motion artifact among those who achieved the goal HR as compared to those who did not (p = 0.001). Logistic regression revealed an increase in the odds of stair step artifact of 11.6% (95% CI: 2.4% decrease, 27.5% increase) per 1 bpm increase in the standard deviation of scan HR. Conclusion: Overall, efficacy of beta-blocker administration to reach target HR is limited. Improvements in CT scanner temporal resolution are mandatory to achieve consistently high image quality independent of HR and beta-blocker administration.

  19. The Role Of Multidetector Computed Tomography In The Early Diagnosis Of Invasive Pulmonary Aspergıllosis In Patients With Febrile Neutropenia Undergoing Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    Nazan Çiledağ

    2012-03-01

    Full Text Available OBJECTIVE: To evaluate the vessel involvement and the role of multidedector computed tomograpy (MDCT in the early diagnosis of invasive pulmonary aspergillosis (IPA at MDCT in autologous bone morrow transplantation patients with febrile neutropenia and antibiotic-resistant fever of unknown origin with clinically suspected IPA. METHODS: 74 pulmonary MDCT examinations of 37 consecutive hematopoietic stem cell transplantation patients with febrile neutropenia with clinically suspected IPA were retrospectively evaluated. RESULTS: The diagnosis of IPA was made according to according to the Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Consensus Group criteria and 0, 14, 11 patients were diagnosed as proven, probable, possible IPA, respectively. Among 25 cases accepted as probable and possible IPA, all patients had pulmonary MDCT findings consistent with IPA. Remaining 12 patients were accepted as having fever of unknown origin (FUO and in these 12, MDCT showed patent vessel. In patients with probable/possible IPA, 72 focal pulmonary lesions were detected. In 41 of 72 (57%, vascular occlusion was detected. The CT halo sign was present in 25 of 41 (61% lesions. A clinical improvement, resolution of fever was observed following antifungal therapy in 19 (76% of 25 patients with probable/possible IPA. Six (25% patients diagnosed as IPA died during follow-up. Transplant related mortality at day 100 in patients with IPA and FUO were found to be 24% and 0%, respectively. CONCLUSION: In conclusion, MDCT has a potential role in early diagnosis of IPA by detection of vessel occlusion.

  20. Multidetector CT of emergent biliary pathologic conditions.

    Science.gov (United States)

    Patel, Neel B; Oto, Aytekin; Thomas, Stephen

    2013-01-01

    Various biliary pathologic conditions can lead to acute abdominal pain. Specific diagnosis is not always possible clinically because many biliary diseases have overlapping signs and symptoms. Imaging can help narrow the differential diagnosis and lead to a specific diagnosis. Although ultrasonography (US) is the most useful imaging modality for initial evaluation of the biliary system, multidetector computed tomography (CT) is helpful when US findings are equivocal or when biliary disease is suspected. Diagnostic accuracy can be increased by optimizing the CT protocol and using multiplanar reformations to localize biliary obstruction. CT can be used to diagnose and stage acute cholecystitis, including complications such as emphysematous, gangrenous, and hemorrhagic cholecystitis; gallbladder perforation; gallstone pancreatitis; gallstone ileus; and Mirizzi syndrome. CT also can be used to evaluate acute biliary diseases such as biliary stone disease, benign and malignant biliary obstruction, acute cholangitis, pyogenic hepatic abscess, hemobilia, and biliary necrosis and iatrogenic complications such as biliary leaks and malfunctioning biliary drains and stents. Treatment includes radiologic, endoscopic, or surgical intervention. Familiarity with CT imaging appearances of emergent biliary pathologic conditions is important for prompt diagnosis and appropriate clinical referral and treatment.

  1. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  2. Clinical application value of 64 row spiral CT to hypertension patients with coronary lesions and left heart function%64排螺旋CT对高血压患者冠脉病变及左心功能的临床应用价值

    Institute of Scientific and Technical Information of China (English)

    饶志荣; 李建胜; 傅晖; 杨友祥; 王宁生; 方快发

    2012-01-01

    Objective To explore the clinical value of 64 row spiral CT to disease characteristics of hypertension patients with coronary artery and evaluation of left heart function. Methods 120 patients with high blood pressure from September 2009 to December 2010 in our hospital were selected. According to the patient's blood pressure levels, all the patients were divided into three groups, high blood pressure level 1, level 2 and level 3 with 40 cases in each group, 40 healthy check-up patients were chosen as control group. 64 row spiral CT were used to cardiac imaging scan, the relationship on the disease characteristics of coronary artery, blood pressure and coronary artery disease and left heart function were analyzed. Results Mild and single pathological changes were found in high blood pressure level 1 group chiefly; double and three teams of lesions were found in high blood pressure level 3 group chiefly, the differences of LVEF.LVEDV.LVESV and LVMM among high blood pressure level 3 group and other groups were all statistically significant (all P < 0.05), except the LVSV. Conclusion The examination of 64 row spiral CT can make accurate judgement to the smooth and narrow degree of coronary artery patients, and can accurately evaluate left cardiac function, and can screen the patients in high blood pressure combined with suspected coronary heart disease.%目的 探讨64排螺旋CT对高血压患者冠状动脉病变特点以及左心功能评估的临床价值.方法 选择2009年9月~2010年12月我院收治的高血压患者120例,根据患者的血压水平将患者分为高血压1级、高血压2级以及高血压3级三组,每组各40例,另外选取健康体检者40例为对照组.使用64排螺旋CT进行心脏成像扫描,分析其冠状动脉的病变特点、血压与冠状动脉病变和左心功能的关系.结果 高血压1级组患者以轻度和单支病变为主,高血压3级阻患者双支和三支病变最多,且除

  3. 64排螺旋CT在诊断成人冠状动脉-肺动脉瘘中的应用价值%Application Value of 64-Row Spiral CT in the Diagnosis of Coronary Artery-Pulmonary Artery Fistula in Adults

    Institute of Scientific and Technical Information of China (English)

    朱红伟

    2014-01-01

    Objective To explore the application value of 64-row spiral CT in the diagnosis of coronary artery-pulmonary artery ifstula in adults.Methods The CT images of 28 adults with coronary artery-pulmonary artery ifstula were retrospectively analyzed.Results Among 28 patients, 10 patients suffered from unilateral vessel lesions, while 18 patients suffered with bilateral vessel lesions. There were 24 patients whose diameter of artery ifstula blood vessels were smaller than that of initial coronary artery, accounting for 85.71%.While 4 patients whose diameter of artery fistula blood vessels were larger than that of initial coronary artery, accounting for 14.29%.Conclusion The 64-Row spiral CT which can clearly show the origin, course and termination of blood vessels, has a great clinical value in the diagnosis of coronary artery-pulmonary artery ifstula.%目的:探讨64排螺旋CT在诊断成人冠状动脉-肺动脉瘘中的应用价值。方法回顾性分析我院28例成人冠状动脉-肺动脉瘘的CT图像。结果28例冠状动脉-肺动脉瘘患者中,单侧分支血管参与者10例,双侧分支血管参与者18例。动脉瘘血管直径较起始冠状动脉直径小的患者有24例,占85.71%;动脉瘘血管直径较起始冠状动脉直径大的患者有4例,占14.29%。结论64排螺旋CT可清晰地显示血管的起源、走行和终止等情况,对冠状动脉-肺动脉瘘的诊断具有重要的临床应用价值。

  4. Clinical Application Value of 64 Row Multislice CT Three-Dimensional and Reconstruction Techniques in the Diagnosis of Rib Fracture%64排多层螺旋CT三维及重建技术在诊断肋骨骨折中的临床应用价值

    Institute of Scientific and Technical Information of China (English)

    高英超; 邹璨

    2016-01-01

    Objective To study the diagnostic value of 64 row multislice CT three-dimensional and reconstruction techniques in the diagnosis of rib fracture.MethodsUsing MSCT scanning on 117 cases of patients with chest trauma, and conducted image reconstruction by CT, MPR and VR technologies, and compared with common CT scan and DR.Results MSCT diagnosed rib fractures correctly in 176 cases, the detection rate was 100%. ConclusionMSCT, MPR and 3 D reconstruction can show the morphology, content and displacement of rib fractures clearly.%目的:评定对肋骨骨折患者诊断工作中,推行64排多层螺旋CT三维及重建技术的可行性。方法采取MSCT方案对117例胸部外伤患者进行扫描,运用CT、MPR及VR等技术进行图像重建并观察和分析,并与DR及普通CT所见进行对照分析。结果 MSCT正确诊断肋骨176处骨折,检出率100%。结论 MSCT、MPR及三维重建能够立体地显示肋骨骨折的部分、形态、骨折程度、骨折移位的特点等空间信息。

  5. Method for Automatic Tube Current Selection for Obtaining a Consistent Image Quality and Dose Optimization in a Cardiac Multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Weiwei; Du, Xiangke [Peking University People' s Hospital, Beijing (China); Li, Jianying [GE Healthcare China, Beijing (China)

    2009-12-15

    To evaluate a quantitative method for individually adjusting the tube current to obtain images with consistent noise in electrocardiogram (ECG)-gated CT cardiac scans. The image noise from timing bolus and cardiac CT scans of 80 patients (Group A) who underwent a 64-row multidetector (MD) CT cardiac examination with patient-independent scan parameters were analyzed. A formula was established using the noise correlation between the timing bolus and cardiac scans. This formula was used to predict the required tube current to obtain the desired cardiac CT image noise based on the timing bolus noise measurement. Subsequently, 80 additional cardiac patients (Group B) were scanned with individually adjusted tube currents using an established formula to evaluate its ability to obtain accurate and consistent image noise across the patient population. Image quality was evaluated using score scale of 1 to 5 with a score of 3 or higher being clinically acceptable. Using the formula, we obtained an average CT image noise of 28.55 Hounsfield unit (HU), with a standard deviation of only 1.7 HU, as opposed to a target value of 28 HU. Image quality scores were 4.03 and 4.27 for images in Groups A and B, respectively, and there was no statistical difference between the image quality scores between the two groups. However, the average CT dose index (CTDIvol) was 30% lower for Group B. Adjusting the tube current based on timing bolus scans may provide a consistent image quality and dose optimization for cardiac patients of various body mass index values.

  6. Instrumentation for multi-detector arrays

    Indian Academy of Sciences (India)

    R K Bhowmik

    2001-07-01

    The new generation of detector arrays require complex instrumentation and data acquisition system to ensure increased reliability of operation, high degree of integration, software control and faster data handling capability. The main features of some of the existing multi-detector arrays like MSU 4 array, Gammasphere and Eurogam are summarized. The instrumentation for the proposed INGA array in India is discussed.

  7. Esophageal injuries: Spectrum of multidetector row CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lutio di Castelguidone, Elisabetta de [Department of Radiology, I.N.T., IRCCS Fondazione G. Pascale, Via M. Semmola, I-80131 Naples (Italy)]. E-mail: e.delutio@virgilio.it; Merola, Stefanella [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Pinto, Antonio [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Raissaki, Maria [Department of Radiology, University Hospital of Iraklion, University of Crete Medical School, P.O. Box 1352, 711 10 Iraklion Crete (Greece); Gagliardi, Nicola [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Romano, Luigia [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, I-80131 Naples (Italy)

    2006-09-15

    Background: Aim of this study is to illustrate the multidetector row computed tomographic findings related to oesophageal injuries and their significance for therapeutic decisions. Method: From April 2002 to April 2005 we studied 16 patients with suspected oesophageal injury. Ten patients underwent standard chest radiograph, while five patients with suspected foreign body ingestion were submitted to cervical plain film and gastrografin swallow study. All 16 patients underwent multidetector row CT examination. Results: In six patients with cervical, thoracic and abdominal trauma, CT showed the presence of thoracic traumatic lesions and findings suggestive of perforation of the oesophagus. In five patients with foreign body ingestion cervical radiography was positive in only one case, while CT showed the presence of a foreign body in all cases. In three patients with post-intubation complications, CT showed the presence of perioesophageal fluid collection containing small gas bubbles in two cases and an oesophageal-aortic fistula in one case. In the remaining two patients with suspected spontaneous oesophageal perforation, CT demonstrated an oesophageal wall oedema and thickening in one case, and oesophageal fluid distension with perioesophageal small bubbles gas and fluid in the second case. Conclusion: Oesophageal injuries, when complicated with perforation, constitute a life-threatening condition. Knowledge of the CT signs of oesophageal injuries has important implications for the role of imaging at the time of initial diagnosis.

  8. Multidetector CT angiography in acute gastrointestinal bleeding: why, when, and how.

    Science.gov (United States)

    Geffroy, Yann; Rodallec, Mathieu H; Boulay-Coletta, Isabelle; Jullès, Marie-Christine; Fullès, Marie-Christine; Ridereau-Zins, Catherine; Zins, Marc

    2011-01-01

    Acute gastrointestinal (GI) bleeding remains an important cause of emergency hospital admissions, with substantial related morbidity and mortality. Bleeding may relate to the upper or lower GI tract, with the dividing anatomic landmark between these two regions being the ligament of Treitz. The widespread availability of endoscopic equipment has had an important effect on the rapid identification and treatment of the bleeding source. However, the choice of upper or lower GI endoscopy is largely dictated by the clinical presentation, which in many cases proves misleading. Furthermore, there remains a large group of patients with negative endoscopic results or failed endoscopy, in whom additional techniques are required to identify the source of GI bleeding. Multidetector computed tomography (CT) with its speed, resolution, multiplanar techniques, and angiographic capabilities allows excellent visualization of both the small and large bowel. Multiphasic multidetector CT allows direct demonstration of bleeding into the bowel and is helpful in the acute setting for visualization of the bleeding source and its characterization. Thus, multidetector CT angiography provides a time-efficient method for directing and planning therapy for patients with acute GI bleeding. The additional information provided by multidetector CT angiography before attempts at therapeutic angiographic procedures leads to faster selective catheterization of bleeding vessels, thereby facilitating embolization. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105206/-/DC1.

  9. 64排螺旋 CT 及三维容积测量系统对肺叶容积的定量研究%The quantitative measurement of pulmonary lobar volume using 3-dimensional volumetric diagnosis system and 64 row MDCT

    Institute of Scientific and Technical Information of China (English)

    刘斋; 何丽; 贾立镯; 任庆云

    2016-01-01

    Objective To explore the value of 3‐dimensional volumetric diagnosis system in quantitative measurement of pulmona‐ry lobar volumetry using a 64 row MDCT .Methods Seventy‐seven adult volunteers were scanned twice on a 64 row MDCT at the end of the maximum inspiratory and maximum expiratory end respectively .On a volumetric computer‐aided diagnosis system ,the en‐tire lung was semiautomatically separated into 5 anatomy lobes including the right upper lobe ,right middle lobe ,right lower lobe ,left upper lobe ,and left lower lobe .Each lobar volume was measured .Results The lung volume of left upper lobe ,right lower lobe ,left lower lobe ,right upper lobe ,right middle lobe in male volunteers were 1 303 .90 mL and 938 .31 mL ,1 276 .90 mL and 737 .69 mL , 1 204 .47 mL and 678 .67 mL ,1 048 .49 mL and 754 .83 mL ,519 .53 mL and 407 .86 mL at the end of the inspiratory and expiratory respectively .The lung volume of left upper lobe ,right lower lobe ,left lower lobe ,right upper lobe ,right middle lobe in female volun‐teers were 915 .78 mL and 666 .23 mL ,913 .87 mL and 576 .62 mL ,822 .17 mL and 509 .30 mL ,734 .20 mL and 530 .23 mL ,389 .13 mL and 316 .70 mL at the end of the inspiratory and expiratory respectively .The values of each lobe volume between the full inspiration phase and expiration phase group showed significant difference the same sex group (P<0 .05) .The values of each lobe volume in the man group were significantly larger than those of female group in both respiratory phase (P<0 .05) .Of the D‐value in the each lobe volume in 5 anatomy lobe at full inspiration phase and expiration phase in both sex group ,both of the lower lobes were the largest , followed by the left upper lobe ,right upper lobe and right middle lobe .The D‐value in the each lobe volume at full inspiration phase and expiration phase in the man group were significantly larger than those of female group .Conclusion Three‐dimensional volumet‐ric diagnosis system

  10. Study on the decrease in scanning radiation of 64 Row of Spiral CT in the Skull & brain of newborn%多排 CT 低剂量不同扫描方法在新生儿颅脑检查中应用

    Institute of Scientific and Technical Information of China (English)

    赵明增

    2013-01-01

    Objective Study the lowest parameter of scanning radiation in 64 Row of Spiral CT used in Skull& brain of newborn ,aiming to decrease radiation .Methods To find the best method and the lowest parameter used in Skull& brain of newborn ,spiral scanning and section scan-ning were used by gradually decreasing scanning parameter .KVP was fixed at 120 KV ,other scanning parameter were gradually decreased by 10mAs .low dose group of section scanning began from 120KV .60mAs ,low dose group of spiral scanning began from120KV .90mAs .20 newborn were scanned at each group ,images of each group were by three image diagnosis expert with senior title ,according to image definition ,gradation and contrast ,concrete anatomy structure in brain tissue ,ventricle ,sulcus as well as detectabilities of lesions ,divided into five levels ,named as high ,good ,general ,poor ,worse quality . ,scored 5 ,4 ,3 ,2 ,1respectively .3 and above 3 were thought as qualified .Results 120KVP .70mAs is the lowest scanning parameter accesable in 64 Row of Spiral CT .120KVP .30mAs is the lowest scanning parameter accesable in section scanning . cmin section scanning .the scanning parameter of two group is 47% and 40% to general scanning respectively .Theparameter in section scanning is 31% to that of spiral scanning .Accordingly ,.Conclusion The best method in 64 Row of Spiral CT used in skull& brain of newborn is section scanning .the lowest scanning parameter is 120KV .40mAs.%目的:探讨多排CT低剂量不同扫描方法在新生儿颅脑检查中的应用,用最佳的检查方法,最小辐射剂量,减少辐射损害。方法用螺旋和横断两种不同扫描方式,采用逐渐降低扫描参数方法,得出新生儿颅脑多排C T扫描可用的最佳方法和最低扫描参数。固定KVP值120 KV和其他扫描参数,每次降低10 mAs。横断法低剂量组扫描参数从120 KVP .60 mAs开始,螺旋法低剂量组扫描参数从120 KV .90 mAs开始。每组扫描20例

  11. Double Chooz Improved Multi-Detector Measurements

    CERN Document Server

    CERN. Geneva

    2016-01-01

    The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero θ13 with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of θ13 followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC’s unique almost "iso-flux" site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of θ13 with respect to the world average. We will address this issue in this seminar. The combined "reactor-θ13" measurement is expected to ...

  12. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  13. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Wanner, Matthew R.; Karmazyn, Boaz [Indiana University School of Medicine, Riley Hospital for Children, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Fan, Rong [Indiana University School of Medicine, Riley Hospital for Children, Department of Pathology and Laboratory Medicine, Indianapolis, IN (United States)

    2015-12-15

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  14. Multidetector CT imaging of mechanical prosthetic heart valves : quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, Petr; Budde, Ricardo P. J.; Westers, Paul; de Mol, Bas A. J. M.; Prokop, Mathias

    2011-01-01

    Objectives Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. Methods

  15. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, P.; Budde, R.P.; Westers, P.; Mol, B.A. de; Prokop, M.

    2011-01-01

    OBJECTIVES: Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. METHODS

  16. Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model

    NARCIS (Netherlands)

    Symersky, P.; Budde, R.P.J.; Westers, P.; de Mol, B.A.J.M.; Prokop, M.

    2011-01-01

    Multidetector computed tomography (MDCT) can detect the cause of prosthetic heart valve (PHV) dysfunction but is hampered by valve-induced artifacts. We quantified artifacts of four PHV using a pulsatile in-vitro model and assessed the relation to leaflet motion and valve design. A Medtronic Hall ti

  17. Role of multi-detector computed tomography (MDCT in management of post percutaneous nephrolithotomy (PCNL bleeding [v1; ref status: indexed, http://f1000r.es/205

    Directory of Open Access Journals (Sweden)

    Arvind P Ganpule

    2013-11-01

    Full Text Available Objective: To evaluate the role of multidetector computerized tomography (MDCT angiography in post percutaneous nephrolithotomy (PCNL bleed and compare findings with conventional angiography (CA. Material and methods: We conducted a retrospective analysis of patients who had post PCNL bleeding and subsequently underwent a MDCT angiography followed by CA. We reviewed eight patients, who presented between January 2009 and January 2013. We performed a MDCT angiography on a 16 slice GE bright speed CT scanner. All angiographies were done by using the Digital Subtraction Angiography Suite. The angioembolisation, if required, was conducted by an interventional nephrologist, specializing in therapeutic embolisation. Results: The mean age of the patients was 42±17 years. Mean time of post PCNL bleed presentation was 10.06±7.9 days. Five patients presented with aneurysm and three presented with an AV fistula with pseudoaneurysm. The right renal unit was involved in six cases and the left in two cases. The lower polar segmental artery was involved in six cases and the upper polar artery in two cases. The CA and MDCT findings matched in all cases and the MDCT helped the clinician to assess and embolise the appropriate arterial tree. Conclusion: MDCT is rapid, reproducible and noninvasive. MDCT angiography performed in the setting of post PCNL bleeding provides an accurate assessment of the site and nature of bleeding. The MDCT angiography matched the CA findings in all patients in the present study.

  18. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Bartalena, Tommaso [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy)], E-mail: t.bartalena@email.it; Giannelli, Giovanni; Rinaldi, Maria Francesca [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy); Rimondi, Eugenio [Department of Radiology, Rizzoli Orthopaedic Institute, Via G.C. Pupilli 1 - 40136 Bologna (Italy); Rinaldi, Giovanni [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy); Sverzellati, Nicola [Department of Clinical Sciences, Section of Radiology, University of Parma, Via Gramsci, 14 - 43100 Parma (Italy); Gavelli, Giampaolo [Department of Radiology, S. Orsola University Hospital, Via Massarenti 9 - 40138 Bologna (Italy)

    2009-03-15

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  19. 64-Row Detector CT Angiography of Aortoiliac and Lower Extremity Arteries:Effect of Using a Monitoring Scan at Knee Level on Image Quality%64层螺旋CT下肢动脉血管造影:腘动脉监测触发对图像质量的影响

    Institute of Scientific and Technical Information of China (English)

    周淑琴; 彭振鹏; 周旭辉; 严超贵; 高樱; 林少春; 李树荣

    2011-01-01

    Purpose: To evaluate the effect of using a monitoring scan at knee level on image quality for 64 - row detector CT angiography of aortoiliac and lower extremity arteries.Methods: The study was performed with approval of the institutional review board and with informed consent of the subjects.A total of 62 subjects were included in this prospective study.The monitoring trigger was sited at knee level of the popliteal artery for CT angiography.Image analysis was performed as follows: Subjective evaluation of the image quality of aorto - iliac area, femoro - popliteal district and run - off vessels with VR and MIP reconstruction respectively; Calculation of the CT value of aorto - iliac area, femoro -popliteal district and run - off vessels; and evaluation of the data by variance analysis; Evalution of the distal arterial and venous visibility.Results: The monitoring scan at the level of the popliteal artery was unavailable in 1 case.The overall quality of VR images in 33 of the 61 patients (54.1%) were categorized as excellent, in 23(37.7% ) as good, in 4(6.6% ) as fair, and in 1(1.6% ) as poor, the rate of excellent and good was 91.8%; MIP images in 41(67.2%)as excellent, in 17(27.9%)as good, for 2(3.3%)as fair, and for 1(1.6%) as poor, the rate of excellent and good was 95.1%.There was a high consistency between two observers (VR: Kappa = 0.719; MIP: Kappa = 0.678).The mean CT values measured at aorto - iliac area, femoro - popliteal district and run - off vessels were 536.42Hu ± 99.68 Hu(352.43 ~ 742.71Hu),541.72Hu ± 119.05 Hu(338.38 ~ 800.75Hu) and 421.29Hu ± 97.15 Hu(264.58 ~ 739.00Hu), respectively.There were significant differences among these three segments(F = 25.25, P = 0.00).The rate of distal arterial and venous visibility were 98.9% (1531/1549)and 22.9% (14/61), respectively.Conclusion: Using a monitoring scan at knee level was useful for 64- row detector CT angiography of aortoiliac and lower extremity arteries

  20. Multidetector CT of the Pancreas

    Directory of Open Access Journals (Sweden)

    Rossella Graziani

    2008-07-01

    Full Text Available Purpose. This book is a practical overview of pancreatic computer tomography (CT based on the large experience of the contributors. It is dedicated to Carlo Procacci a well known radiologist of Verona who died in 2004. Content. The book is divided into 10 chapters covering the different aspects of diagnostic CT of the pancreas. The various radiological aspects of acute and chronic pancreatitis, exocrine and endocrine pancreatic cancer (adenocarcinoma, neuroendocrine tumors, cystic cancer, rare neoplasms, traumatic abnormalities, imaging aspects of the gland after surgery and finally imaging findings after pancreas transplantation are reported in detail. Comment. We would emphasize that the characteristics of imaging of the common pancreatic diseases are described in addition to unusual or rare aspects of pancreatic pathology. The iconography is very rich and it is of excellent quality and it will help the radiologist to deal with individual cases particularly complex. Another important aspect of the book is that the initial approach of the various pancreatic diseases is based on clinical, surgical and pathological aspects and their relationship with imaging findings. Limitation. It is a great pity that the book for its importance is written in Italian language and for this reason it can not have an international appreciation. Final note. The radiologists will find in the book all the information useful for their daily practice. The internists, gastroenterologists and surgeons also will found useful information to better understand the information given by the modern CT radiology.

  1. 64层螺旋CT脑灌注成像联合CT血管造影评价颅内外血管搭桥术后疗效%Assessment of cerebral internal and external vascular bypass graft in patients with single middle cerebral artery stenosis or occlusion by combining 64-row CT cerebral perfusion with angiography

    Institute of Scientific and Technical Information of China (English)

    陈天金; 朱栓庄; 温有信; 王耀彬; 韩向东; 白莹; 于旋

    2012-01-01

    Objective To assess the curative effect of cerebral internal and external vascular bypass graft in patients with sin -gle middle cerebral artery (MCA) stenosis or occlusion by combining 64 -row CT cerebral perfusion (CTP) with angiography ( CTA ). Methods Patients with middle cerebral artery stenosis or occlusion were recruited and underwent superficial temporal artery and mid -die cerebral artery(STA -MCA) bypass graft between March 2009 and Mar 2011. CTP and CTA examinations were performed in all patients before and after operation. The cerebral perfusion parameters were analyzed quantitatively and qualitatively . The origin, travel and anastomotic stoma of bypass grafts were evaluated by reconstructed CTA images . Results 46 patients were found with severe MCA stenosis or occlusion. The time to peak (TTP) and relative mean transit time (rMTT) images before therapy displayed the existence of perfusion delay. The relative cerebral blood flow (rCBF) and relative cerebral blood volume (rCRV) images did not change significantly. The decrease of TTP and rMTT after therapy was of statistical significance ( P 0.05). In reconstructed CTA images , 82 bridge vessels were well displayed, including double bridges in 39 patients. The accuracy of CTA examination was 96.5%. All the bypass grafts were well shown and the anastomotic stomas were unobstructed. Conclusions It is feasible to evaluate the curative effects of cerebral internal and ex — ternal vascular bypass graft by combining CTP images of cerebral perfusion after therapy with CTA images of cerebral internal and exter -nal bypass grafts.%目的 探讨64层螺旋CT脑灌注成像(CT perfusion,CTP)联合CT血管造影(CT angiography,CTA)评价单侧大脑中动脉(middle cerebral artery,MCA)重度狭窄(闭塞)颅内外血管搭桥术后疗效的可行性.方法 46例拟行颅内外血管搭桥术患者,术前、后均行CTP及CTA检查.计算脑灌注参数图,对治疗前后脑灌注参数进行定量和定性对

  2. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von;

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...

  3. Accessory cardiac bronchus: Proposed imaging classification on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Min; Kim, Young Tong; Han, Jong Kyu; Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of)

    2016-02-15

    To propose the classification of accessory cardiac bronchus (ACB) based on imaging using multidetector computed tomography (MDCT), and evaluate follow-up changes of ACB. This study included 58 patients diagnosed as ACB since 9 years, using MDCT. We analyzed the types, division locations and division directions of ACB, and also evaluated changes on follow-up. We identified two main types of ACB: blind-end (51.7%) and lobule (48.3%). The blind-end ACB was further classified into three subtypes: blunt (70%), pointy (23.3%) and saccular (6.7%). The lobule ACB was also further classified into three subtypes: complete (46.4%), incomplete (28.6%) and rudimentary (25%). Division location to the upper half bronchus intermedius (79.3%) and medial direction (60.3%) were the most common in all patients. The difference in division direction was statistically significant between the blind-end and lobule types (p = 0.019). Peribronchial soft tissue was found in five cases. One calcification case was identified in the lobule type. During follow-up, ACB had disappeared in two cases of the blind-end type and in one case of the rudimentary subtype. The proposed classification of ACB based on imaging, and the follow-up CT, helped us to understand the various imaging features of ACB.

  4. Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings.

    Science.gov (United States)

    Artigas, José M; Martí, Milagros; Soto, Jorge A; Esteban, Helena; Pinilla, Inmaculada; Guillén, Eugenia

    2013-01-01

    Acute gastrointestinal bleeding is a common reason for emergency department admissions and an important cause of morbidity and mortality. Factors that complicate its clinical management include patient debility due to comorbidities; intermittence of hemorrhage; and multiple sites of simultaneous bleeding. Its management, therefore, must be multidisciplinary and include emergency physicians, gastroenterologists, and surgeons, as well as radiologists for diagnostic imaging and interventional therapy. Upper gastrointestinal tract bleeding is usually managed endoscopically, with radiologic intervention reserved as an alternative to be used if endoscopic therapy fails. Endoscopy is often less successful in the management of acute lower gastrointestinal tract bleeding, where colonoscopy may be more effective. The merits of performing bowel cleansing before colonoscopy in such cases might be offset by the resultant increase in response time and should be weighed carefully against the deficits in visualization and diagnostic accuracy that would result from performing colonoscopy without bowel preparation. In recent years, multidetector computed tomographic (CT) angiography has gained acceptance as a first-line option for the diagnosis and management of lower gastrointestinal tract bleeding. In selected cases of upper gastrointestinal tract bleeding, CT angiography also provides accurate information about the presence or absence of active bleeding, its source, and its cause. This information helps shorten the total diagnostic time and minimizes or eliminates the need for more expensive and more invasive procedures.

  5. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    Energy Technology Data Exchange (ETDEWEB)

    Ferda, Jiri [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic)], E-mail: ferda@fnplzen.cz; Hora, Milan [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic); Hes, Ondrej [Institut of Pathology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Reischig, Tomas [Department of Internal Medicine, Nephrology Unit, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Kreuzberg, Boris; Mirka, Hynek; Ferdova, Eva; Ohlidalova, Kristyna; Baxa, Jan [Department of Radiology, Charles University Hospital Plzen, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Urge, Tomas [Department of Urology, Charles University Hospital Plzen, Dr. Edvarda Benese 13, CZ-306 40 Plzen (Czech Republic)

    2007-08-15

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC

  6. Estudio vascular renal por TC multidetector de 64 canales 64-Multidetector row CT for the Renal Vascular Study

    Directory of Open Access Journals (Sweden)

    Daniela Stoisa

    2009-03-01

    Full Text Available Objetivo: Mostrar las diversas variantes anatómicas vasculares tanto arteriales como venosas en el estudio angiográfico renal por tomografìa computada multidetector (TCMD de 64 canales, dada su implicancia en un eventual planeamiento quirúrgico. Material y métodos: Evaluamos retrospectivamente 26 estudios realizados con tomógrafo Philips Brilliance de 64 canales. Se obtuvieron secuencias sin contraste y postcontraste e.v. en fases arterial y venosa, administrado con bomba inyectora doble cabezal. Para una fase arterial apropiada se utilizó técnica de bolus track. Las imágenes fueron posteriormente procesadas en Workstation Philips Brilliance 190P en un tiempo promedio de 30 minutos y reconstruidas con técnicas MIP y volumétrica. Resultados: Dentro de las variantes anatómicas arteriales, encontramos: bifurcaciones prehiliares (n=3, arterias accesorias (n=4 y arterias polares (n=9. Dentro de las variantes venosas fueron halladas: venas renales múltiples (n=5, venas circumaórticas (n=2, retroaórticas (n=2 y vena tributaria lumbar prominente (n=1. Conclusión: El estudio vascular renal adquiere importancia en el planeamiento quirúrgico en casos de nefrectomías parciales, laparoscópicas y en el transplante renal. Esto otorga suma utilidad al estudio de TCMD de 64 canales por su eficacia diagnóstica, dada la alta calidad de las reconstrucciones obtenidas, llegando a igualar a la angiografía digital, sin ser un método invasivo.Purpose: To show the wide range of anatomical vascular variants, arterial and venous, that can be seen in the angiographic renal study using 64-multidetector-row computed tomography (64-MDCT, due to its importance in an eventual surgical planning. Material and Methods: We have evaluated retrospectively 26 studies that have been done using a 64 channels Philips Brilliance CT scanner. We have obtained non enhanced and both in arterial and venous enhanced sequences. For the injection of the contrast material we

  7. Three-Dimensional Volume-Rendered Series Complements 2D Orthogonal Multidetector Computed Tomography in the Evaluation of Abnormal Spinal Curvature in Patients at a Major Cancer Center: A Retrospective Review

    OpenAIRE

    2012-01-01

    Background. Abnormal spinal curvature is routinely assessed with plain radiographs, MDCT, and MRI. MDCT can provide two-dimensional (2-D) orthogonal as well as reconstructed three-dimensional volume-rendered (3-D VR) images of the spine, including the translucent display: a computer-generated image set that enables the visualization of surgical instrumentation through bony structures. We hypothesized that the 3-D VR series provides additional information beyond that of 2-D orthogonal MDCT in ...

  8. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  9. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  10. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  11. Three-Dimensional Volume-Rendered Series Complements 2D Orthogonal Multidetector Computed Tomography in the Evaluation of Abnormal Spinal Curvature in Patients at a Major Cancer Center: A Retrospective Review.

    Science.gov (United States)

    Debnam, J Matthew; Ketonen, Leena; Guha-Thakurta, Nandita

    2012-01-01

    Background. Abnormal spinal curvature is routinely assessed with plain radiographs, MDCT, and MRI. MDCT can provide two-dimensional (2-D) orthogonal as well as reconstructed three-dimensional volume-rendered (3-D VR) images of the spine, including the translucent display: a computer-generated image set that enables the visualization of surgical instrumentation through bony structures. We hypothesized that the 3-D VR series provides additional information beyond that of 2-D orthogonal MDCT in the evaluation of abnormal spinal curvature in patients evaluated at a major cancer center. Methods. The 3-D VR series, including the translucent display, was compared to 2-D orthogonal MDCT studies in patients with an abnormal spinal curvature greater than 25 degrees and scored as being not helpful (0) or helpful (1) in 3 categories: spinal curvature; bony definition; additional findings (mass lesions, fractures, and instrumentation). Results. In 38 of 48 (79.2%) patients assessed, the 3-D VR series were scored as helpful in 63 of 144 (43.8%) total possible categories (32 spinal curvature; 14 bony definition; 17 additional findings). Conclusion. Three-dimensional MDCT images, including the translucent display, are complementary to multiplanar 2-D orthogonal MCDT in the evaluation of abnormal spinal curvature in patients treated at a major cancer center.

  12. Use of multidetector CT in the diagnosis of Moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales-de Larrazabal, C.; Bhoey, H.K.; Lim, M.C.L. [Singapore Heart, Stroke and Cancer Centre, Ngee Ann City (Singapore)

    2005-07-01

    This article presents an adult case of moyamoya disease, diagnosed with CT angiography, and discusses the value of using a multidetector CT scan in the diagnosis of the disease. The patient's previous MRA and conventional angiography are used for comparison. (orig.)

  13. Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: Initial results

    Institute of Scientific and Technical Information of China (English)

    Miriam Klauβ; Max Sch(o)binger; Ivo Wolf; Jens Werner; Hans-Peter Meinzer; Hans-Ulrich Kauczor; Lars Grenacher

    2009-01-01

    AIM: To evaluate the use of three-dimensional imaging of pancreatic carcinoma using multidetector computed tomography (CT) in a prospective study. METHODS: Ten patients with suspected pancreatic tumors were examined prospectively using multidetector CT (Somatom Sensation 16, Siemens, Erlangen, Germany). The images were evaluated for the presence of a pancreatic carcinoma and invasion of the peripancreatic vessels and surrounding organs. Using the isotropic CT data sets, a three-dimensional image was created with automatic vascular analysis and semiautomatic segmentation of the organs and pancreatic tumor by a radiologist. The CT examinations and the three-dimensional images were presented to the surgeon directly before and during the patient's operation using the Medical Imaging Interaction Toolkit-based software "ReLiver". Immediately after surgery, the value of the two images was judged by the surgeon. The operation and the histological results served as the gold standard. RESULTS: Nine patients had a pancreatic carcinoma (all pT3), and one patient had a serous cystadenoma. One tumor infiltrated the superior mesenteric vein. The infiltration was correctly evaluated. All carcinomas were resectable. In comparison to the CT image with axial and coronal reconstructions, the three-dimensional image was judged by the surgeons as better for operation planning and consistently described as useful. CONCLUSION: A 3D-image of the pancreas represents an invaluable aid to the surgeon. However, the 3D-software must be further developed in order to be integrated into daily clinical routine.

  14. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  15. MULTIDETECTOR CT STUDY OF ANATOMICAL VARIANTS OF ETHMOID SINUS

    Institute of Scientific and Technical Information of China (English)

    李玉华; 薛建平; 朱铭

    2004-01-01

    Objective To evaluate the significance of multidetector CT 3D reconstruction technique in showing anatomy of ethmoid sinus, at the same time, anatomic variations of ethmoid sinus and its clinical significance were also discussed. Methods 250 cases of ethmoid sinuses were scanned transversally by multidetector scaner, coronal and sagittal views were reconstructed. Results Coronal and sagittal views were good enough to make diagnosis. 5 kinds of common ethmoid sinus variations were seen, including pneumatization of ethmoid bulla (56. 5% ) , Onodi air cell(26% ) , Hailer cell(6. 5% ) ,low ethmoid foveolas( 4. 3% )and over intromigratiny lamella papyracea (6. 5% ). Conclusion The coronal and other special views of ethmoid sinus are showed clearly by 3 D reconstruction which can provide detailed image informations for functional endoscopic sinus surgery.

  16. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    LENUS (Irish Health Repository)

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  17. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  18. Acute gastrointestinal bleeding: emerging role of multidetector CT angiography and review of current imaging techniques.

    Science.gov (United States)

    Laing, Christopher J; Tobias, Terrence; Rosenblum, David I; Banker, Wade L; Tseng, Lee; Tamarkin, Stephen W

    2007-01-01

    Acute gastrointestinal bleeding is a common cause of hospitalization, morbidity, and mortality in the United States. The evaluation and treatment of acute gastrointestinal bleeding are complex and often require a multispecialty approach involving gastroenterologists, surgeons, internists, emergency physicians, and radiologists. The multitude of pathologic processes that can result in gastrointestinal bleeding, the length of the gastrointestinal tract, and the often intermittent nature of gastrointestinal bleeding further complicate patient evaluation. In addition, there are multiple imaging modalities and therapeutic interventions that are currently being used in the evaluation and treatment of acute gastrointestinal hemorrhage, each with its own strengths and weaknesses. Initial experience indicates that multidetector computed tomographic angiography is a promising first-line modality for the time-efficient, sensitive, and accurate diagnosis or exclusion of active gastrointestinal hemorrhage and may have a profound impact on the evaluation and subsequent treatment of patients who present with acute gastrointestinal bleeding.

  19. Intracardiac Eustachian Valve Cyst in an Adult Detected with Other Cardiac Anomalies: Usefulness of Multidetector CT in Diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyung Ji; Jung, Jung Im; Kim, Hwan Wook; Lee, Kyo Young [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2012-07-15

    We present an unusual case of an intracardiac Eustachian valve cyst observed concurrently with atresia of the coronary sinus ostium, a persistent left superior vena cava (LSVC) and a bicuspid aortic valve. There have been several echocardiographic reports of Eustachian valve cysts; however, there is no report of multidetector computed tomography (MDCT) findings related to a Eustachian valve cyst. Recently, we observed a Eustachian valve cyst diagnosed on MDCT showing a hypodense cyst at the characteristic location of the Eustachian valve (the junction of the right atrium and inferior vena cava). MDCT also demonstrated additional cardiovascular anomalies including atresia of the coronary sinus ostium and a persistent LSVC and bicuspid aortic valve.

  20. Life-threatening gastrointestinal system bleeding in Hodgkin disease: multidetector CT findings and review of the literature.

    Science.gov (United States)

    Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun

    2007-06-01

    Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.

  1. Study of Coronary Arteries by Means of Multidetector CT; Estudio de las arterias coronarias mediante tomografia computarizada multidetector

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, G. C.; Costas, M. I.; Delgado, C.; Velasco, M.; Tardaguila, F. [Hospital POVISA. Vigo. Pontevedra (Spain)

    2004-07-01

    Radiological study of coronary arteries has undergone major advances,especially with the incorporation of new CT multidetectors which afford temporary spatial resolution sufficient for the acquisition of high-quality images and diagnoses concerning various coronary artery abnormalities. The technique is described in terms of both facilitating data within a procedure making use of beta-blockers to slow heart rate and postprocess image reconstruction. Accordingly, our experience with a 16-detector CT and its clinical applications are illustrated. (Author)

  2. EDEN - A NEUTRON TIME-OF-FLIGHT MULTIDETECTOR FOR DECAY STUDIES OF GIANT STATES

    NARCIS (Netherlands)

    LAURENT, H; LEFORT, H; BEAUMEL, D; BLUMENFELD, Y; FORTIER, S; GALES, S; GUILLOT, J; ROYNETTE, JC; VOLKOV, P; BRANDENBURG, S

    1993-01-01

    A neutron time-of-flight multidetector has been built to study the decay of giant states. It is made of 40 individual detectors. A liquid scintillator is used for neutron-gamma-ray pulse shape discrimination. The overall efficiency of the multidetector (epsilonOMEGA/4pi) is 1% for 6 MeV neutrons and

  3. Scenes from the past: multidetector CT of Egyptian mummies of the Redpath Museum.

    Science.gov (United States)

    Wade, Andrew D; Garvin, Gregory J; Hurnanen, Jaana H; Williams, Licd Lana; Lawson, Barbara; Nelson, Andrew J; Tampieri, Donatella

    2012-01-01

    As a nondestructive method of historical and anthropologic inquiry, imaging has played an important role in mummy studies over the past several decades. Recent technologic advances have made multidetector computed tomography (CT) an especially useful means for deepening the present understanding of ancient cultures by examining preserved human remains. In April 2011, three ancient Egyptian human mummies from the Redpath Museum of McGill University were examined with 320-section multidetector CT as part of the IMPACT Radiological Mummy Database project headquartered at the University of Western Ontario. Whole-body scanning was performed with a section thickness of 0.5 mm and a peak voltage of 120 kVp, and the raw CT datasets were postprocessed by using smooth body and high-resolution bone convolution filters. Two of the mummies were scanned at different energy levels (80 and 135 keV). The high-resolution CT scans revealed the details of mummification and allowed observations about the socioeconomic and health status of the human subjects based on both the mummification technique used and the appearance of the remains, particularly the bones and teeth. The paleopathologic information obtained from the scans confirmed some findings in studies performed in the same mummies in the late 19th and 20th centuries. The CT scans also demonstrated a high degree of variability in Egyptian mortuary practice, variability that is not generally recognized in the literature. Unusual features that were observed included a relatively uncommon retained heart in mummy RM2718, retained lungs in a mummy from which the heart had been extracted (RM2720), and a cartonnage plaque placed over the left abdomen of a mummy that had been eviscerated transperineally (RM2717).

  4. CT angiography of pulmonary embolism using a 64 slice multi-detector scanner

    Institute of Scientific and Technical Information of China (English)

    QIN Nai-shan; JIANG Xue-xiang; QIU Jian-xing; ZHU Ying; WANG Ji-chen

    2009-01-01

    Background Multi-detector computed tomography (MDCT) has already been the first line investigation method for diagnosis of pulmonary embolism (PE). Reducing the amount of contrast medium used during CT scanning could decrease the incidental rate of adverse reactions. Our study amied to evaluate the image quality of pulmonary arteries using 64 slice multi-detector CT with small volumes of contrast media injection.Methods Forty nonconsecutive patients without PE or other lung diseases were randomly assigned to two groups.Group A underwent CT scanning with 16×1.25 mm collimation and a 70 ml contrast injection, while group B had CT with 64×0.625 mm collimation and 20 ml of contrast injection. Two readers independently depicted the segmental and subsegmental pulmonary arteries. Reasons we could not analyze the pulmonary artery or that led to misdiagnosis of pulmonary embolism were evaluated, including the degree of contrast enhancement of the main pulmonary artery, and factors that caused misdiagnosis of PE (flow-related artifacts, partial volume artifact, beam-hardening artifacts and enhancement of pulmonary vein). The independent samples t-test, Mann-Whitney U test and Pearson chi-square test were applied.Results There were no significant differences in image quality of segmental and subsegmental arteries between the two groups. No significant difference was found for factors that made pulmonary arteries non-analyzable or in the misdiagnosis of PE, except the degree of contrast enhancement.Conclusion 64×0.625 mm collimation with 20 ml contrast injection could depict the pulmonary arteries well.

  5. Stress myocardial perfusion imaging with multidetector CT

    NARCIS (Netherlands)

    A. Rossi (Alexia); D. Merkus (Daphne); E. Klotz (Ernst); N.R.A. Mollet (Nico); P.J. de Feyter (Pim); G.P. Krestin (Gabriel)

    2014-01-01

    textabstractComputed tomographic (CT) coronary angiography is a well-established, noninvasive imaging modality for detection of coronary stenosis, but it has limited accuracy in demonstrating whether a coronary stenosis is hemodynamically significant. An additional functional test is often required

  6. Adult Moyamoya disease: 320-Multidetector row CT for evaluation of revascularization in STA–MCA bypasses surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Bing; Xu, Bing; Liu, Qi; Hao, Qiang; Lu, Jianping, E-mail: cjr.lujianping@vip.163.com

    2013-12-01

    Purpose: To evaluate the utility of 320-multidetector row whole-brain computed tomography perfusion (WBCTP) and whole-head subtracted dynamic angiography (WHSDCTA) for assessing the revascularization of blood flow after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in adults with Moyamoya disease (MD) in the short and long term. Patients and methods: 320-multidetector row WBCTP and WHSDCTA were applied in 20 patients with MD before and after surgery (for an average of 3 days and 3 months). The bypass arteries were investigated using WHSDCTA and compared with DSA. The regions of interests (ROIs) in the surgical and mirror sides of the cerebral cortex were drawn on a Vitrea Workstation. Cerebral blood volume (CBV), time to peak (TTP), cerebral blood flow (CBF), mean transit time (MTT), and delay time were recorded. Preoperative and postoperative perfusion parameters in the MCA distribution were compared using the paired t-test. Results: WHSDCTA could clearly demonstrate 24 bypass arteries in 26 arteries for 20 patients, results which were in accordance with the results of digital subtraction angiography (DSA). When comparing preoperative values to those within 3 days after surgery, only TTP and delay time were significantly different (P < 0.05). Values of CBV, TTP, CBF, delay time, and MTT 3 months after surgery were significantly different (P < 0.05) from those of preoperative perfusion. Conclusion: These data suggest that 320-multidetector row WBCTP and WHSDCTA can be used to evaluate the revascularization of blood flow after STA–MCA bypass surgery in patients with MD in the short and long term.

  7. Pneumomediastinum on Multidetector CT: The Radiologic Signs and Underlying Disorders

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Soo Jin; Kim, Young Tong [Soonchunhyang University Chunan Hospital, Cheonan (Korea, Republic of)

    2011-02-15

    We can see the typical signs of pneumomediastinum on chest radiography and we can also see them on the multiplanar reformatted (MPR) image of multidetector CT (MDCT). MDCT can help to understand the anatomical feature of these signs and differentiate pneumomediastinum from pneumothorax, pneumopericardium and the Mach band effect. MDCT shows the peribronchovascular air, which reveals the Macklin effect, and it can also evaluate the underlying disorders that cause pneumomediastinum. The purpose of this pictorial essay is to inform physicians about the mechanism and anatomical features of pneumomediastinum, and to help them understand the imaging findings and underlying disorders of pneumomediastinum as seen on MDCT

  8. Multidetector CT of pulmonary cavitation: filling in the holes.

    Science.gov (United States)

    Mortensen, K H; Babar, J L; Balan, A

    2015-04-01

    Pulmonary cavitation causes significant morbidity and mortality. Early diagnosis of the presence and aetiology of a cavity is therefore crucial in order to avoid further demise in both the localized pulmonary and systemic disorders that may manifest with pulmonary cavity formation. Multidetector CT has become the principal diagnostic technique for detecting pulmonary cavitation and its complications. This review provides an overview of the aetiologies and their imaging findings using this technique. Combining a literature review with case illustration, a synopsis of the different imaging features and constellations is provided, which may suggest a particular cause and aid the differentiation from diseases with similar findings.

  9. Acute stent thrombosis after bifurcation stenting with the crush technique visualized with 64-slice computed tomography

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Engstrom, T.; Kofoed, Klaus Fuglsang

    2008-01-01

    Acute stent thrombosis remains a potential complication after stent implantation. With the introduction of electrocardiographic gated multidetector row computed tomography (MDCT), a new nonnvasive imaging modality has become available that may contribute to the detection of complications after...

  10. Toroid cavity/coil NMR multi-detector

    Science.gov (United States)

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  11. Aortic Stenosis: Evaluation with Multidetector CT Angiography and MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Eun Ju; Choi, Sang Il; Lim, Cheong; Park, Kye Hyun; Chang, Hyuk Jae; Choi, Dong Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kim, Dong Hun [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Lee, Whal; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2008-10-15

    Aortic valvular stenosis (AS) is the most common valve disease which results in the need for a valve replacement. Although a Doppler echocardiography is the current reference imaging method, the multidetector computerized tomography (MDCT) and magnetic resonance imaging (MRI) have recently emerged as a promising method for noninvasive valve imaging. In this study, we briefly describe the usefulness and comparative merits of the MDCT and MRI for the evaluation of AS in terms of valvular morphology (as the causes of AS), quantification of aortic valve area, pressure gradient of flow (for assessment severity of AS), and the evaluation of the ascending aorta and cardiac function (as the secondary effects of AS). The familiarity with the MDCT and MRI features of AS is considered to be helpful for the accurate diagnosis and proper management of patients with a poor acoustic window.

  12. Enhanced security for multi-detector quantum random number generators

    Science.gov (United States)

    Marangon, Davide G.; Vallone, Giuseppe; Zanforlin, Ugo; Villoresi, Paolo

    2016-11-01

    Quantum random number generators (QRNG) represent an advanced solution for randomness generation, which is essential in every cryptographic application. In this context, integrated arrays of single-photon detectors have promising applications as QRNGs based on the spatial detection of photons. For the employment of QRNGs in cryptography, it is necessary to have efficient methods to evaluate the so-called quantum min-entropy that corresponds to the amount of the true extractable quantum randomness from the QRNG. Here, we present an efficient method that allows the estimation of the quantum min-entropy for a multi-detector QRNG. In particular, we consider a scenario in which an attacker can control the efficiency of the detectors and knows the emitted number of photons. Eventually, we apply the method to a QRNG with 103 detectors.

  13. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  14. Normal or abnormal? Demystifying uterine and cervical contrast enhancement at multidetector CT.

    Science.gov (United States)

    Yitta, Silaja; Hecht, Elizabeth M; Mausner, Elizabeth V; Bennett, Genevieve L

    2011-01-01

    Computed tomography (CT) is not generally advocated as the first-line imaging examination for disorders of the female pelvis. However, multidetector CT is often the modality of choice for evaluating nongynecologic pelvic abnormalities, particularly in emergent settings, in which all the pelvic organs are invariably assessed. Incidental findings of uterine and cervical contrast enhancement in such settings may easily be mistaken for abnormalities, given the broad spectrum of anatomic variants and enhancement patterns that may be seen in the normal uterus and cervix. The authors' review of CT and magnetic resonance (MR) imaging enhancement patterns, augmented by case examples from their clinical radiology practice, provides a solid foundation for understanding the spectrum of normal uterine and cervical appearances and avoiding potential pitfalls in the diagnosis of benign cervical lesions, adenomyosis, infection, malignancy, and postpartum effects. This information should help radiologists more confidently differentiate between normal and abnormal CT findings and, when CT findings are not definitive, offer appropriate recommendations for follow-up ultrasonography or MR imaging.

  15. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma

    Institute of Scientific and Technical Information of China (English)

    Luigi; Camera; Rosa; Severino; Antongiulio; Faggiano; Stefania; Masone; Gelsomina; Mansueto; Simone; Maurea; Rosa; Fonti; Marco; Salvatore

    2014-01-01

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography(CT) or magnetic resonance(MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved bysomatostatin-receptor scintigraphy(SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR(Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT(Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure(3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  16. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L. [Kantonsspital, Institute of Radiology, Winterthur (Switzerland); Patak, Michael A. [Kantonsspital, Institute of Radiology, Winterthur (Switzerland); Inselspital, University Hospital of Bern, Institute of Diagnostic, Interventional and Paediatric Radiology, Bern (Switzerland); Erturk, Sukru M. [Sisli Etfal Education and Research Hospital, Department of Radiology, Istanbul (Turkey)

    2008-09-15

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  17. Optimised low-dose multidetector CT protocol for children with cranial deformity

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Jose Luis [Complejo Hospitalario Universitario de Vigo, Department of Radiology, Vigo, Pontevedra (Spain); Pombar, Miguel Angel [Complejo Hospitalario Universitario de Santiago, Department of Radiophysics, Santiago de Compostela, La Coruna (Spain); Pumar, Jose Manuel [Complejo Hospitalario Universitario de Santiago, Department of Radiology, Santiago de Compostela, La Coruna (Spain); Campo, Victor Miguel del [Complejo Hospitalario Universitario de Vigo, Department of Public Health, Vigo, Pontevedra (Spain)

    2013-08-15

    To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity. Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used. The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT. A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. (orig.)

  18. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma.

    Science.gov (United States)

    Camera, Luigi; Severino, Rosa; Faggiano, Antongiulio; Masone, Stefania; Mansueto, Gelsomina; Maurea, Simone; Fonti, Rosa; Salvatore, Marco

    2014-10-28

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography (CT) or magnetic resonance (MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved by somatostatin-receptor scintigraphy (SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR (Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT (Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure (3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  19. A comparative review of multidetector CT angiography and MRI in the diagnosis of jugular foramen lesions

    Energy Technology Data Exchange (ETDEWEB)

    Christie, A., E-mail: andychristie90@hotmail.co [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom); Teasdale, E. [Radiology Department, Institute of Neurosciences, Glasgow, Scotland (United Kingdom)

    2010-03-15

    Aim: To compare the efficiency of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the diagnosis of jugular foramen lesions. Materials and methods: The imaging of 15 patients with tumours predominantly occurring at the jugular foramen was retrospectively reviewed, with postoperative pathology data available for 11 patients. MDCT was performed at arterial phase and MRI with standard sequences and contrast enhancement. All imaging was blindly re-reported by an experienced neuroradiologist. Results: Pathology reported six glomus jugulare tumours and five neuromas, which were all correctly diagnosed using MDCT. A confident diagnosis was also made in the remaining four cases based on the pattern of enhancement. Only glomus tumours enhanced in the arterial phase. Overall, MRI was used to make a confident diagnosis in eight patients. One showed no enhancement and was correctly diagnosed as a neuroma, and seven demonstrated the tumour flow voids characteristic of a glomus tumour. The remaining seven cases all showed a similar enhancement pattern and could not be confidently differentiated between a neuroma or a glomus tumour. MDCT angiography enabled a confident assessment of the jugular vein in all cases, but MRI was inconclusive in a third of cases. Also, in the nine cases of glomus tumour diagnosed using MDCT, an enlarged feeding artery was identified in eight patients. Conclusion: MDCT is more accurate than MRI in diagnosing glomus tumours, and in particular, neuromas. It also offers valuable preoperative vascular information to the surgeon.

  20. Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography

    Energy Technology Data Exchange (ETDEWEB)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas Horst; Guenther, Rolf W.; Wildberger, Joachim Ernst [University Hospital, University of Technology (RWTH), Department of Diagnostic Radiology, Aachen (Germany); Weiss, Claudia [RWTH Aachen, Institute of Medical Statistics, Aachen (Germany); Schoepf, U. Joseph [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States); Leidecker, Christianne [Institute of Medical Physics, University of Erlangen, Erlangen (Germany)

    2006-02-01

    The aims of this study were to optimize image quality for indirect CT venography (sequential versus spiral), and to evaluate different image reconstruction parameters for patients with suspected deep venous thrombosis (DVT). Fifty-one patients (26/25 with/without DVT) were prospectively evaluated for pulmonary embolism (PE) with standard multidetector-row computed tomography (MDCT) protocols. Retrospective image reconstruction was done with different slice thicknesses and reconstruction increments in sequential and spiral modes. All reconstructions were read for depiction of DVT and to evaluate best reconstruction parameters in comparison with the thinnest reconstruction (''gold standard''). Image noise and venous enhancement were measured as objective criteria for image quality. Subjective image quality was rated on a four-point scale. Effective dose was estimated for all reconstructions. In sequential 10/50 reconstruction DVT was completely detected in 13/26 cases, partially in 10/26 cases and was not detected at all in 3/26 cases, and 15/26, 9/26 and 2/26 cases for the 10/20 reconstruction, respectively. DVT was completely detected in all spiral reconstructions. Image noise ranged between 14.8-29.1 HU. Median image quality was 2. Estimated effective dose ranged between 2.3 mSv and 11.8 mSv. Gaps in sequential protocols may lead to false negative results. Therefore, spiral scanning protocols for complete depiction of DVT are mandatory. (orig.)

  1. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  2. Computed tomography of acute pulmonary embolism: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Meinel, Felix G.; McQuiston, Andrew D.; Ravenel, James G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2015-09-15

    Multidetector computed tomography (CT) plays an important role in the detection, risk stratification and prognosis evaluation of acute pulmonary embolism. This review will discuss the technical improvements for imaging peripheral pulmonary arteries, the methods of assessing pulmonary embolism severity based on CT findings, a multidetector CT technique for pulmonary embolism detection, and lastly, how to avoid overutilization of CT pulmonary angiography and overdiagnosis of pulmonary embolism. (orig.)

  3. Multidetector row-CT in evaluation of living renal donors

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ji-qing; HU Xiao-peng; WANG Wei; LI Xiao-bei; YIN Hang; ZHANG Xiao-dong

    2010-01-01

    Background Multidetector-row CT (MDCT) has been evolving to the standard evaluating method of potential living donor in most centers, and can provide excellent details for selecting candidates and determining surgical technique.This study aimed to assess the value of MDCT in evaluation of the anatomy of living kidney donors and to reveal the prevalence of renal vascular variations in a Chinese population.Methods One hundred and four potential donors underwent MDCT and the data sets were post-processed for reformatted images with various techniques, such as maximum intensity projection (MIP), a volume-rendering technique (VR), and multiplanar reformation (MPR). Donor nephrectomies were performed on 97 candidates after MDCT evaluation with the findings during surgery constituting the standard of reference. Resulting MDCT images were compared with actual anatomy found during surgery. Results The MDCT images accurately displayed the anatomic structure of the main renal arteries and veins as well as the upper ureters, except in one case with horseshoe kidney. The prevalence of accessory arteries revealed in images was 27.2% (28/103) and early branching was found in 12.6% (13/103). Compared with findings during surgery, the detection of accessory arteries in MDCT images was 85.7% (6/7), and the detection of larger accessory arteries (>1.5 mm in diameter) was 100%. Detection of early branching was 100%.Conclusion MDCT helps accurately evaluate the renal anatomy of potential donors thus facilitating the planning of surgery.

  4. Spine fractures in falling accidents: analysis of multidetector CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Bensch, Frank V.; Kiuru, Martti J.; Koivikko, Mika P.; Koskinen, Seppo K. [Department of Radiology, Toeoeloe Trauma Center, Helsinki University Central Hospital, Topeliuksenkatu 5, 00029, Helsinki (Finland)

    2004-04-01

    The purpose of the present study was to assess incidence, fracture type, and location of spine fractures due to falls. All emergency room CT requests during a time period of 26 months were reviewed retrospectively. Patients who had fallen or jumped and were initially examined with multidetector CT (MDCT) were included. The MDCT studies were evaluated by two radiologists for trauma location, fracture type, and multiple level involvement. A total of 237 patients (184 males, 53 female, age range 16-86 years, mean age 42 years) met the inclusion criteria. A total of 203 vertebral fractures were seen in 127 patients. Burst fracture (n=78) was the most frequent type of trauma, usually located in the thoracolumbar junction (50%). Also, compression fracture (n=52) was most common in the thoracolumbar junction (39%). Posterior column fracture (n=52) was most frequently detected in the cervical spine (40%). Multiple-level spine fractures were seen in 41 (32%) of the injured patients, of which 12 (29%) had fractures at noncontinuous levels. With increasing height the overall incidence of fractures increased, and burst fractures and multiple level spine fractures became more frequent. Age had no effect on fracture type or location. Spine fractures due to falls are common. Burst fracture is the most common fracture type and most frequently seen in the thoracolumbar junction. Multiple-level fractures were seen in 32% of the cases, of which 29% were seen at noncontinuous levels. Serious spine fractures are seen in all falling height and age groups. (orig.)

  5. First experiences with multidetector CT in traumatized children

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, Marcus E-mail: marcus.hoermann@univie.ac.at; Scharitzer, Martina; Philipp, M.; Metz, Viktor M.; Lomoschitz, F

    2003-10-01

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment.

  6. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  7. Are bone erosions detected by magnetic resonance imaging and ultrasonography true erosions? A comparison with computed tomography in rheumatoid arthritis metacarpophalangeal joints

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Ejbjerg, B.; Court-Payen, M.;

    2006-01-01

    The objective of the study was, with multidetector computed tomography (CT) as the reference method, to determine whether bone erosions in rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints detected with magnetic resonance imaging (MRI) and ultrasonography (US), but not with radiography...

  8. Variantes anatómicas vasculares halladas de manera incidental en estudios de tomografía computada Incidental findings of vascular anatomic variants on computed tomography

    Directory of Open Access Journals (Sweden)

    Alejandro Rodriguez

    2013-03-01

    incidentally found on computed tomography imaging. Materials and Methods. A total of 3586 scans were performed between June 2010 and June 2011 with 16-row and a 64-row Multidetector CT scanners. Findings included: right aortic arch, aberrant right subclavian artery, aberrant left subclavian vein, left superior vena cava, left inferior vena cava, double inferior vena cava, circumaortic renal vein, retroaortic left renal vein, subhepatic vein and azygous continuation of the inferior vena cava. Conclusion. Vascular anatomical variants are found with relative frequency on CT scans requested for other reasons. To be familiar with these anomalies may prevent confusions, diagnostic errors and unnecessary complementary exams and forces us to search for other associated anomalies.

  9. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  10. 64排128层螺旋CT图像重建技术对胆脂瘤型中耳炎的术前评估价值%The Value of Preoperative Assessment about Otitis Media with Cholesteatoma by Image Reconstruction of 64-Multidetector 128-Slice Computer Tomography

    Institute of Scientific and Technical Information of China (English)

    相丽; 郑穗生

    2011-01-01

    Obiective To explore the advantages and disadvantages of post-processing techniques of MSCT to the manifestation of bone destruction in ears with otitis media with cholesteatoma. Materials and Methods fmage reconstruction of 64-multidetector 128-slice CT were performed to middle and internal ears of 42 ears with otitis media with cholesteatoma in different ways. The images were compared to intraoperative findings, and the concordance of the two underwent Kappa test. SPSS was used to deal with the results. High concordance was defined as Kappa ≥0.75. Acceptable concordance was defined as 0. 41/Ukappa"00.75. Low concordance was defined as Kappa"U0.4. Results Kappa values of head of malleus, long crus of incus, short crus of incus, body of incus body, bone destruction of meningeal board, aditus ad antrum expanding and structure defects of horizontal segment of facial nerve canal were greater than 0.75L?Kappa values of handle of malleus, incudomelleolar joints, horizontal and labyrinthin segment of facial nerve canal, semicircular canal, scutum, bone wall of sigmoid sinus and bone destruction of labyrinth were between 0.4 and 0.75, but Kappa values of incudostapedial joint, anterior crus of stapes, posterior crus of stapes and bone destruction of footplate of stapes were less than 0.4. Conclusions Images of bone destruction in middle and internal ears with otitis media with cholesteatoma have important reference value for the operation.%目的 探讨MSCT后处理技术对胆脂瘤型中耳炎骨质破坏情况显示的优劣势.材料与方法 采用64排128层螺旋CT对42耳胆脂瘤型中耳炎中耳及内耳结构进行多种方式重建,结果与术中所见对照,Kappa检验二者的一致性,采用SPSS11.0软件包处理,规定 Kappa值大于或等于0.75为两者有很高的一致程度,其值在0.4-0.75说明一致程度尚可.小于0.4则说明一致程度不够理想.结果 锤骨头、砧骨长脚、砧骨短脚、砧骨体、脑膜板骨壁骨质破坏

  11. Decreased Renal Function Is a Risk Factor for Subclinical Coronary Atherosclerosis in Korean Postmenopausal Women

    Science.gov (United States)

    Yun, Bo Hyon; Chon, Seung Joo; Cho, Si Hyun; Choi, Young Sik; Lee, Byung Seok

    2016-01-01

    Objectives Decreased renal function is associated with increased cardiovascular risk. Our study was planned to verify the association of decreased renal function and subclinical coronary atherosclerosis in postmenopausal women. Methods We performed a retrospective review of 251 Korean postmenopausal women who visited the health promotion center for a routine health checkup. Estimated glomerular filtration rate (eGFR) was used to show renal function, which was estimated by calculated using the Cockcroft-Gault (CG) and the modification of diet in renal disease (MDRD) formulas. Coronary atherosclerosis was assessed by 64-row multidetector computed tomography. Results Women with reduced eGFR (menopausal hormone therapy before atherosclerosis development. PMID:28119897

  12. Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Cotroneo, A.R.; Giammarino, A. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy); Spigonardo, F. [Department of Vascular Surgery, University ' G. D' Annunzio' , Chieti (Italy); Storto, M.L. [Department of Clinical Science and Bioimaging, Section of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2011-07-15

    Purpose: To investigate the possibility of reducing radiation dose exposure while maintaining image quality using multidetector computed tomography angiography (MDCTA) with high-concentration contrast media in patients undergoing follow-up after endovascular aortic repair (EVAR) to treat abdominal aortic aneurysm. Materials and methods: In this prospective, single center, intra-individual study, patients underwent two consecutive MDCTA scans 6 months apart, one with a standard acquisition protocol (130 mAs/120 kV) and 120 mL of iomeprol 300, and one using a low dose protocol (100 mAs/80 kV) and 90 mL of iomeprol 400. Images acquired during the arterial phase of contrast enhancement were evaluated both qualitatively and quantitatively for image noise and intraluminal contrast enhancement. Results: Thirty adult patients were prospectively enrolled. Statistically significantly higher attenuation values were measured in the low-dose acquisition protocol compared to the standard protocol, from the suprarenal abdominal aorta to the common femoral artery (p < 0.0001; all vascular segments). Qualitatively, image quality was judged significantly (p = 0.0002) better with the standard protocol than with the low-dose protocol. However, no significant differences were found between the two protocols in terms of contrast-to-noise ratio (CNR) (13.63 {+-} 6.97 vs. 11.48 {+-} 8.13; p = 0.1058). An overall dose reduction of up to 74% was observed for the low-dose protocol compared with the standard protocol. Conclusion: In repeat follow-up examinations of patients undergoing EVAR for abdominal aortic aneurysm, a low-dose radiation exposure acquisition protocol provides substantially reduced radiation exposure while maintaining a constant CNR and good image quality.

  13. Study of statistical properties of hybrid statistic in coherent multidetector compact binary coalescences search

    Science.gov (United States)

    Haris, K.; Pai, Archana

    2016-05-01

    In this article, we revisit the coherent gravitational wave search problem of compact binary coalescences with multidetector network consisting of advanced interferometers like LIGO-Virgo. Based on the loss of the optimal multidetector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio (MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives few false alarms compared to the multidetector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We demonstrate that, for a LIGO-Virgo network and binary inclination ɛ 11 0 ° , the hybrid statistic captures more than 98% of the network optimum matched filter SNR with a low false alarm rate. The Monte Carlo exercise with two distributions of incoming inclination angles—namely, U [cos ɛ ] and a more realistic distribution proposed by B. F. Schutz [Classical Quantum Gravity 28, 125023 (2011)]—are performed with the hybrid statistic and give approximately 5% and 7% higher detection probabilities, respectively, compared to the two stream multidetector MLR statistic for a fixed false alarm probability of 1 0-5.

  14. Jejunal GIST causing acute massive gastrointestinal bleeding: role of multidetector row helical CT in the preoperative diagnosis and management.

    Science.gov (United States)

    Daldoul, Sami; Moussi, Amir; Triki, Wissem; Baraket, Rym Bennaceur; Zaouche, Abdeljelil

    2012-09-01

    In this report, we describe a 34-year-old man with a jejunal gastrointestinal stromal tumour (GIST) accompanied by an unusual severe haemorrhage. Because oesophagogastroduodenoscopy proved inconclusive in determining the source of the bleeding and also because of gradually dropping haemoglobin levels and persistence of the melena not allowing colonic preparation, colonoscopy was cancelled and a mesenteric angio-computed tomography (angio-CT) was deemed necessary. The results of this analysis showed a 5-cm heterogeneous mass located in the jejunal loop surrounded by abnormal arterial structures. This multidetector computed tomography (MDCT) appearance was highly suggestive of GIST. The patient then underwent an urgent laparotomy and, peroperative findings being compatible with angio-CT descriptions, a small-bowel resection was performed. The results of the histopathological examination confirmed the diagnosis of GIST. Angio-CT helps define the size of GIST as well as its range and location and can be used as the primary routine test for patients suffering from lower-GI bleeding.

  15. Deepgoing study on intrathoracic tuberculous lymphadenitis in adults using multidetector CT

    Institute of Scientific and Technical Information of China (English)

    LUO Ming-yue; LIU Li; LAI Li-sha; DONG Yun-xu; LIANG Wen-wei; QIN Jie

    2010-01-01

    Background Studies on intrathoracic tuberculous lymphadenitis in adults are confined to the preliminary CT findings with ordinary CT and ordinary spiral CT.There has been no deepgoing study of multidetector CT to date.Multidetector CT could contribute to better imaging of intrathoracic tuberculous lymphadenitis in adults.The purpose of this study was to explore the multidetector CT features of intrathoracic tuberculous lymphadenitis in adults, and the correlation with clinical symptoms and pathologic changes.Methods Multidetector CT findings from 42 consecutive adult patients with intrathoracic tuberculous lymphadenitis were analyzed retrospectively with regard to locations, sizes, numbers, shapes, margins, and densities reviewing precontrast and enhanced images.CT results were correlated with clinical symptoms and pathologic results (n=37).Results One hundred and eighty-five intrathoracic lymph nodes that had tuberculous lymphadenitis in 42 patients were distributed mainly in regions 4R (n=37), 2R (n=33), 7 (n=31) and 10R (n=21), more than 2 regions were implicated in 34 patients.One hundred and twenty-two (72.2%) of the tuberculous lymphadenitis without confluence were oval or round with clear margins.On precontrast scanning, 78.4% of tuberculous lymphadenitis had a homogeneous density.Seven enhancement patterns were demonstrated in 169 tuberculous lymphadenitis from 37 patients with pathologic results:homogeneous enhancement with no clinical symptom (n=12), corresponded pathologically to tuberculous hyperplasia without caseous necrosis; heterogeneous enhancement with a small central no enhancement area, slight clinical symptoms (n=22), tuberculous granulomas with a little caseous necroses; peripheral irregular thick wall enhancement with a central area with no enhancement, slight clinical symptoms (n=52), tuberculous granulomas with some caseous necroses in the center; peripheral thin rim enhancement with a central area having no enhancement, moderate clinical

  16. Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Lim, Yeon Soo; Lee, Youn Joo; Yoo, Won Jong; Sung, Mi Sook (Dept. of Radiology, Bucheon St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Bucheon (Korea, Republic of)), email: wjyu@catholic.ac.kr; Kim, Bum Soo (Dept. of Radiology, Seoul St Mary' s Hospital, Coll. of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of))

    2012-05-15

    Background: There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose: To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods: We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results: There were excellent inter-observer agreements for the lumen diameter measurements (P < 0.001). The mean diameter of the stented vessels was 2.10 +- 0.31 mm on digital subtraction angiography (DSA), 0.93 +- 0.20 mm on CTA using B30, 1.18 +- 0.27 mm on CTA using B50, and 1.29 +- 0.29 mm on CTA using B60. The mean ALN was 55.7 +- 6.0% on CTA using B30, 43.8 +- 7.5% on CTA using B50, and 38.7 +- 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant (P < 0.001). Conclusion: The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after

  17. Investigating the low-dose limits of multidetector CT in lung nodule surveillance.

    Science.gov (United States)

    Paul, N S; Siewerdsen, J H; Patsios, D; Chung, T B

    2007-09-01

    The purpose of this study was to evaluate the factors limiting nodule detection in thoracic computed tomography (CT) and to determine whether prior knowledge of nodule size and attenuation, available from a baseline CT study, influences the minimum radiation dose at which nodule surveillance CT scans can be performed while maintaining current levels of nodule detectability. Multiple nodules varying in attenuation (-509 to + 110 HU) and diameter (1.6 to 9.5 mm) were layered in random and ordered sequences within 2 lung cylinders made of Rando lung material and suspended within a custom-built CT phantom. Multiple CT scans were performed at varying kVp (120, 100, and 80), mA (200, 150, 100, 50, 20, and 10), and beam collimation (5, 2.5, and 1.25 mm) on a four-row multidetector scanner (Lightspeed, General Electric, Milwaukee, WI) using 0.8 s gantry rotation. The corresponding range of radiation dose over which images were acquired was 0.3-26.4 mGy. Nine observers independently performed three specific tasks, namely: (1) To detect a 3.2 mm nodule of 23 HU; (2) To detect 3.2 mm nodules of varying attenuation (-509 to -154 HU); and (3) To detect nodules varying in size (1.6-9 mm) and attenuation (-509 to 110 HU). A two-alternative forced-choice test was used in order to determine the limits of nodule detection in terms of the proportion of correct responses (Pcorr, related to the area under the ROC curve) as a summary metric of observer performance. The radiation dose levels for detection of 99% of nodules in each task were as follows: Task 1 (1 mGy); Task 2 (5 mGy); and Task 3 (7 mGy). The corresponding interobserver confidence limits were 1, 5, and 10 mGy for Tasks 1, 2, and 3, respectively. There was a fivefold increase in the radiation dose required for detection of lower-density nodules (Tasks 1 to 2). Absence of prior knowledge of the nodule size and density (Task 3) corresponds to a significant increase in the minimum required radiation dose. Significant image

  18. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  19. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Energy Technology Data Exchange (ETDEWEB)

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  20. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    Energy Technology Data Exchange (ETDEWEB)

    Addley, H.C., E-mail: helenclareaddley@hotmail.co.u [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Griffin, N.; Shaw, A.S.; Mannelli, L. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Parker, R.A. [Department of Medical Statistics, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Aitken, S.; Wood, H. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Davies, S. [Department of Histopathology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Alexander, G.J. [Department of Hepatology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Lomas, D.J. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-04-15

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size {<=}20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  1. Nuclear structure at high spin using multidetector gamma array and ancillary detectors

    Indian Academy of Sciences (India)

    S Muralithar

    2014-04-01

    A multidetector gamma array (GDA), for studying nuclear structure was built with ancillary devices namely gamma multiplicity filter and charged particle detector array. This facility was designed for in-beam gamma spectroscopy measurements in fusion evaporation reactions at Inter-University Accelerator Centre, New Delhi. Description of the facility and in-beam performance with two experimental studies done are presented. This array was used in a number of nuclear spectroscopic and reaction investigations.

  2. Paradigm of pretest risk stratification before coronary computed tomography

    DEFF Research Database (Denmark)

    Jensen, Jesper Møller; Øvrehus, Kristian; Nielsen, Lene H;

    2009-01-01

    BACKGROUND: The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. OBJECTIVE: We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary ...

  3. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  4. Study of statistical properties of hybrid statistic in coherent multi-detector CBC Search

    CERN Document Server

    Haris, K

    2015-01-01

    In this article, we revisit the problem of coherent multi-detector search of gravitational wave from compact binary coalescence with Neutron stars and Black Holes using advanced interferometers like LIGO-Virgo. Based on the loss of optimal multi-detector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio(MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives low false alarms compared to the multi-detector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We have demonstrated that for a LIGO-Virgo network and binary inclination, \\epsilon 110 deg., the hybrid statistic captures more than 98% of network optimum matched filter SNR with low false alarm rate. The...

  5. Imaging of Herniated Discs of the Cervical Spine: Inter-Modality Differences between 64-Slice Multidetector CT and 1.5-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Ji Sook; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Han, Jong Kyu [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Kim, Hyun Joo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2015-08-15

    To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI.

  6. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Willemink, M. J.; Zhao, Y.; de Jong, P. A.; van Ooijen, P. M. A.; Oudkerk, M.; Greuter, M. J. W.; Vliegenthart, R.

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12mm; CT density 1100 Hounsfield units (HU)] were randomly placed ins

  7. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  8. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  9. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  10. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  11. Double Chooz: optimizing the sensitivity to {theta}{sub 13} with a multi-detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Novella, P. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain)

    2012-08-15

    The best upper limit to the neutrino mixing angle {theta}{sub 13} is set by the CHOOZ experiment. The eventual measurement of {theta}{sub 13} in reactor neutrino experiments relies on a reduction of the CHOOZ systematics of about 1 order of magnitude, along with a major increase of the luminosity. Provided that enough statistics are achieved, fighting the systematics becomes the key towards {theta}{sub 13}. The Double Chooz experiment engages this fight with a multi-detector set up.

  12. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.

    Science.gov (United States)

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-12-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.

  13. Pitfalls in detection of acute gastrointestinal bleeding with multi-detector row helical CT.

    Science.gov (United States)

    Stuber, T; Hoffmann, M H K; Stuber, G; Klass, O; Feuerlein, S; Aschoff, A J

    2009-07-01

    Contrast-enhanced multi-detector row helical CT angiography is establishing itself as an accurate, rapid, and non-invasive diagnostic modality in patients with acute gastrointestinal bleeding. On arterial phase MDCT images ongoing hemorrhage can be revealed as an area of active extravasation of contrast material within the bowel lumen. This pictorial essay gives a short overview of current diagnostic modalities in assessing acute GI tract bleeding, typical MDCT findings, and depicts potential pitfalls in the detection of acute GI bleeding with MDCT.

  14. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  15. Importance of multidetector CT imaging in multiple trauma; Stellenwert der Multidetektor-CT bei Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U. [HELIOS Kliniken Muenchen West, HELIOS Klinik Muenchen Perlach, Institut fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Geyer, L.L.; Reiser, M.; Wirth, S. [Klinikum der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Koerner, M. [Radiologie Muehleninsel, Landshut (Germany)

    2014-09-15

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [German] Die Diagnostik komplexer Mehrfachverletzungen ist eine Herausforderung fuer die moderne radiologische Notfalldiagnostik. Eine umfassend angelegte, fruehe und praezise radiologische Diagnostik ist entscheidend fuer eine prioritaetenorientierte und

  16. Multidetector computed tomography (MDCT angiography of thoracic aortic coarctation in pediatric patients: Pre-operative evaluation

    Directory of Open Access Journals (Sweden)

    Mohamad Zakaryia Al-Azzazy

    2014-03-01

    Conclusion: We concluded that MDCT angiography with multiplanar and three dimensional techniques can be considered the modality of choice for pre-operative assessment of coarctation of the thoracic aorta in pediatric patients.

  17. Utility of multidetector row computed tomography in the management of hemoptysis: An experience from Upper Egypt

    Directory of Open Access Journals (Sweden)

    Sherif A.A. Mohamed

    2016-01-01

    Conclusion: Our results confirm that MDCT angiography is a useful method to identify and depict the bronchial arteries and to predict the presence of nonbronchial systemic vessels that supply a parenchymal lesion. MDCT angiography allows a rapid and detailed identification of abnormal vasculature and provides a precise road map which can be used to guide therapeutic arterial embolization.

  18. Prognostic value of multi-detector computed tomography in asymptomatic aortic valve stenosis

    DEFF Research Database (Denmark)

    Larsen, Linnea Hornbech; Kofoed, Klaus Fuglsang; Carstensen, Helle Gervig;

    2016-01-01

    was defined as indication for aortic valve replacement (AVR) determined by the treating physician or sudden cardiac death. RESULTS: The mean age was 72 (8) years, 27% were women, mean AVA by TTE was 1.01 (0.30) cm(2). Median follow up time was 27 (IQR 19-44) months. Forty seven patients (41%) developed...... indication for AVR. No patients suffered a sudden cardiac death. AVA and aortic valve calcification were significant univariable predictors of AVR when measured by both TTE and MDCT, whereas left ventricular mass was only significant measured by MDCT. Significant coronary artery disease by MDCT tended...... to predict future indication for AVR, but this did not reach statistical significance (HR: 1.79 (95% CI 0.96-3.44), p=0.08). CONCLUSION: MDCT derived AVA can be of use as an alternative to TTE derived AVA in patients with asymptomatic AS to predict future clinical indication for AVR....

  19. Diagnostic Potential of Multidetector Computed Tomography for Characterizing Small Renal Masses

    Directory of Open Access Journals (Sweden)

    Maria Elisabetta Mancini

    2015-01-01

    Full Text Available Objectives. To assess the potential of CT for characterizing small renal tumors. Methods. 76 patients with <4 cm renal tumors underwent CT examination. The following parameters were assessed: presence of calcifications, densitometry on unenhanced and enhanced scans, washout percentage, urinary tract infiltration, star-shaped scar, and paradoxical effect. Results. Calcifications were found in 7/56 (12.5% carcinomas. Clear cell carcinomas were as follows: mean density 183.5 HU (arterial phase, 136 HU (portal phase, and 94 HU (delayed phase, washout 34.3%; chromophobe carcinomas were as follows: mean density 135 HU (arterial phase, 161 HU (portal phase, and 148 HU (delayed phase, washout 28%; papillary carcinomas were as follows: mean density 50.3 HU (arterial phase, 60 HU (portal phase, and 58.1 HU (delayed phase, washout 2.7%. In 2/56 (3.6% cases urinary tract infiltration was found. Oncocytomas were as follows: mean density 126.5 HU (arterial phase, 147.5 HU (portal phase, and 115.5 HU (delayed phase, washout 28.6%. On unenhanced scans, angiomyolipomas were as follows: density values <30 HU in 12/12 (100% of cases and on enhanced scans: mean density 78 HU (arterial phase, 128 HU (portal phase, and 80 HU (delayed phase, washout 50%. Conclusions. Intralesional calcifications and urinary tract infiltration are suggestive for malignancy, with the evidence of adipose tissue for angiomyolipomas and a modest increase in density with a reduced washout for papillary carcinomas. The intralesional density on enhanced scans, peak enhancement, and washout do not seem significant for differentiating clear cell, chromophobe carcinomas, angiomyolipomas, and oncocytomas.

  20. Multi-detector computed tomography (MDCT findings of chemotherapy induced hepatic chan

    Directory of Open Access Journals (Sweden)

    Sieza Samir Abd-Allah

    2016-09-01

    Results: Forty patients (32 females and 8 males had hepatic changes due to effect of chemotherapy. The most common CT finding was fatty liver. Hepatic fatty changes were detected in 36/40 patients. These fatty changes were diffuse, focal fatty and diffuse with fatty spare area. Four patients had capsular retraction: 1 patient with HD and 3 patients with metastatic cancer breast. Veno-occlusive disease and biliary sclerosis were not detected.

  1. Diagnostic performance of multidetector computed tomography in the evaluation of esoph

    Directory of Open Access Journals (Sweden)

    Tarek ELKammash

    2016-03-01

    Conclusion: MDCT is a fast, well tolerable, non-invasive procedure and accepted from most of the examined patients for evaluation and grading of EV, detection of other portosystemic collaterals and hepatobiliary pathologies.

  2. Assessment of left ventricular function after mitral valvular replacement using multidetector row computed tomography: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Byun, Joo Nam [Chosun University, College of Medicine, Kwangju (Korea, Republic of); Ryu, Sang Wan [Miraero21 Hospital, Kwangju (Korea, Republic of); Choi, Sang Il [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2008-04-15

    To assess the usefulness of cardiac MDCT for the evaluation of cardiac function and morphology of mitral valve replacement (MVR) with or without subvalvular preservation. Sixteen patients with (n = 10) or without (n = 6) subvalvular sparing and control subjects (n = 6) were evaluated using 16-slice MDCT (Sensation 16, Siemens, Erlangen, Germany). Images of MDCT were reconstructed for the evaluation of cardiac morphology and ventricular function. Patients were compared with respect to variables such as ejection fraction (EF), end-diastolic volume (EDV), and-systolic volume (ESV), and the diastolic-systolic left ventricular area ratio on a short-axis view at apical, mid-ventricular, and basal levels. The average values for cardiac function variables for control subjects and after MVR (with subvalvular preservation versus without subvalvular preservation) were, respectively, 54 {+-} 8%, 54 {+-} 7% and 44 {+-} 6%, for EF; 91 {+-} 28 ml, 108 {+-} 35 ml and 99 {+-} 33 ml for EDV; 43 {+-} 19 ml, 52 {+-} 24 ml and, 56 {+-} 21 ml for ESV. The area ratio was 2.56, 2.75, 2.09 at the apex; 2.20, 2.17, 1.56 at the mid-ventricular level; 1.90, 1.87, 1.76 at the basal level, respectively. Mid ventricular contraction for patients following subvalvular resection was significantly decreased ({rho} < 0.05). MDCT is a useful diagnostic modality for functional and morphologic evaluation of MVR.

  3. Pancreatic and peri-pancreatic lesions mimic pancreatic islet cell tumor in multidetector computed tomography

    Institute of Scientific and Technical Information of China (English)

    XUE Hua-dan; LIU Wei; XIAO Yu; SUN Hao; WANG Xuan; LEI Jing; JIN Zheng-yu

    2011-01-01

    Objective This pictorial review aimed to summarize the most possible differential diagnosis of pancreatic islet cell tumor (PICT).Data sources Data used in this review were mainly from Medline and Pubmed in English. And all clinical images in this review were from Department of Radiology, Peking Union Medical College Hospital, Beijing, China.Study selection Cases of pancreatic cystadenoma, solid pseudo-papillary tumor of the pancreas, pancreatic metastasis, pancreatic adenocarcinoma, para-pancreatic neuroendocrine tumors, Castleman disease, gastrointestinal stromal tumor, splenic artery aneurysm and accessory spleen were selected in this pictorial review for differential diagnosis of PICT.Results Careful analysis of imaging features and correlation with the clinical manifestations may allow a more specific diagnosis. It is also important that the radiologist is familiar with the anatomic variants and disease entities which mimic pancreatic islet cell tumor in order to avoid an improper treatment protocol.Conclusions Many congenital anatomic variants or other pancreatic and peri-pancreatic diseases may mimic MDCT appearance of pancreatic islet cell tumor. Radiological, clinical and pathological characteristics should be considered for the final diagnosis.

  4. Computer

    CERN Document Server

    Atkinson, Paul

    2011-01-01

    The pixelated rectangle we spend most of our day staring at in silence is not the television as many long feared, but the computer-the ubiquitous portal of work and personal lives. At this point, the computer is almost so common we don't notice it in our view. It's difficult to envision that not that long ago it was a gigantic, room-sized structure only to be accessed by a few inspiring as much awe and respect as fear and mystery. Now that the machine has decreased in size and increased in popular use, the computer has become a prosaic appliance, little-more noted than a toaster. These dramati

  5. Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Tae Won [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Lee, Jeong Min; Kim, Jung Hoon [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Yu, Mi Hye [Department of Radiology, Konkuk University Medical Center, Seoul 05030 (Korea, Republic of); Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080 (Korea, Republic of)

    2016-11-01

    To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of 'SPL per se' and 'SPL in consideration of secondary features', the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. The sensitivity of MRI for 'detection of SPL per se' was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for 'detection of SPL in consideration of secondary features', specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.

  6. Comparison of multidetector CT and gadobutrol-enhanced MR imaging for evaluation of small, solid pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Tae Won; Lee, Jeong Min; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Yu, Mi Hye [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of 'SPL per se' and 'SPL in consideration of secondary features', the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. The sensitivity of MRI for 'detection of SPL per se' was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for {sup d}etection of SPL in consideration of secondary features{sup ,} specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.

  7. Regenerative nodules in patients with chronic Budd-Chiari syndrome: A longitudinal study using multiphase contrast-enhanced multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Flor, Nicola [Unita Operativa di Radiologia Diagnostica Interventistica, University of Milan School of Medicine, Ospedale San Paolo, Milan (Italy)], E-mail: flornic@hotmail.com; Zuin, Massimo [Unita Operativa di Epatologia e Gastroenterologia Medica, University of Milan School of Medicine, Ospedale San Paolo, Via A. di Rudini 8, 20142 Milan (Italy); Brovelli, Francesca [Department of Radiology, Centro Diagnostico Italiano, Milan (Italy); Maggioni, Marco [Servizio di Anatomia Patologica, Ospedale San Paolo, Milan (Italy); Tentori, Augusta [Servizio di Radiologia, Ospedale di Voghera (Italy); Sardanelli, Francesco [Radiology, IRCCS Policlinico San Donato, University of Milan School of Medicine, Milan (Italy); Cornalba, Gian Paolo [Unita Operativa di Radiologia Diagnostica Interventistica, University of Milan School of Medicine, Ospedale San Paolo, Milan (Italy)

    2010-03-15

    Objective: Our aim was to evaluate the serial evolution of regenerative nodules in patients with Budd-Chiari syndrome (BCS) treated with portal-systemic shunts, using multiphasic multidetector computed tomography (MDCT). Materials and methods: Five patients each underwent three MDCT exams over an extended period ranging from 36 to 42 months. Two radiologists in consensus retrospectively reviewed each exam for each patient. Individual nodules were grouped according to size (size I: nodules with diameter {<=}15 mm; size II: >15 mm but <30 mm; size III: {>=}30 mm), pattern of enhancement (A: homogeneously hypervascular or B: with central scar), and segmental location. Four nodules classified as size II, which increased in size over time, were needle-biopsied. Results: We detected 61 nodules at the first exam, 66 nodules at the second exam (7 nodules disappeared and 12 new nodules), and 85 nodules at the third exam (8 disappeared and 27 new) for a total of 212 findings. Nodules were mostly found in the right hepatic lobe. Fourteen of the 15 nodules that disappeared over time were size I and enhancement pattern A. At unenhanced MDCT, 204 (96%) of the 212 findings were isodense. Overall, 100 nodules, including the 61 initially detected, were considered newly diagnosed; of these 84 (84%) were size I and pattern A. Of 57 nodules considered size I and pattern A at the first or second exam, 24 (42%) changed to pattern B at the third exam and either size II (n = 18) or III (n = 6). The four biopsied nodules were each confirmed as benign regenerative nodule. No patient developed HCC at 5-year follow-up period. Conclusion: Hepatic nodules in BCS patients not only increase in number over time but may also increase in size and develop a central scar.

  8. Anatomical analysis of incidental left atrial diverticula in patients with suspected coronary artery disease using 64-channel multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.Y. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Kwon, S.H., E-mail: Kwon98@khu.ac.kr [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Oh, J.H. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2011-10-15

    Aim: To describe and evaluate anatomical characterizations of incidental left atrial (LA) diverticula in patients with suspected coronary artery disease using 64-channel multidetector computed tomography (MDCT). Materials and methods: From October 2008 to June 2009, 2059 patients with suspected coronary artery disease underwent electrocardiogram-gated 64-channel MDCT. Five hundred and thirty-two LA diverticula were identified in 377 patients (18.3%, male to female ratio: 216:161, mean age 59 {+-} 10.89 years, range from 20 to 91 years). Two radiologists retrospectively analysed the number (single or multiple), size (diameter and length), shape (cystiform or tubiform), surface (smooth or irregular), and location (right or mid or left/upper or lower/lateral or posterior). If the length/diameter was <1.5, the diverticular shape was considered to be cystiform. Results: Among 532 LA diverticula, single (270/532, 51.1%), cystiform (411/532, 77.3%), and smooth (332/532, 62.4%) diverticula were found. The right upper region (255/532, 47.9%) was the most common location, followed by the left lateral area (172/532, 32.3%). The average diameter was 4.7 {+-} 2 mm (range from 1-19 mm), and the average length was 4.7 {+-} 2.1 mm (range 1-13 mm). The average ratio of length to diameter was 1.15 (range 0.25-1.45). The average number of diverticula was 2 {+-} 1.06 (range 1-5). Conclusion: Incidental LA diverticulum is not an uncommon finding in patients with suspected coronary artery disease. MDCT can provide anatomical details of LA diverticula. However, further studies are needed to determine their clinical significance.

  9. Optimisation of vascular input and output functions in CT-perfusion imaging using 256(or more)-slice multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Niesten, Joris M.; Schaaf, Irene C. van der; Riordan, Alan J.; Jong, Hugo W.A.M. de; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)

    2013-05-15

    To evaluate the accuracy and reproducibility of CT-perfusion (CTP) by finding the optimal artery for the arterial input function (AIF) and re-evaluating the necessity of the venous output function (VOF). Forty-four acute ischaemic stroke patients who underwent non-enhanced CT, CTP and CT-angiography using 256-slice multidetector computed tomography (MDCT) were evaluated. The anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery were selected as the AIF. Subsequently the resulting area under the time-enhancement curve of the AIF (AUC{sub AIF}) and quantitative perfusion measurements were analysed by repeated measures ANOVA and subsequently the paired t test. To evaluate reproducibility we examined if the VOF could be deleted by comparing the perfusion measurements using versus not using the VOF (paired t test). The AUC{sub AIF} and perfusion measurements resulting from the different AIFs showed significant group differences (all P < 0.0001). The ICA had the largest AUC{sub AIF} and resulted in the highest mean transient time (MTT) and lowest cerebral blood flow (CBF), whereas the basilar artery showed the lowest cerebral blood volume (CBV). Not using the VOF showed significantly higher CBV and CBF in 66 % of patients on the ipsilateral (P < 0.0001 and P = 0.007, respectively) and contralateral hemisphere (P < 0.0001 and P = 0.019, respectively). Selecting the ICA as the AIF and continuing the use of the VOF would improve the accuracy of CTP. (orig.)

  10. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  11. COMPUTING

    CERN Document Server

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  12. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  13. A Clinical Evaluation of Cone Beam Computed Tomography

    Science.gov (United States)

    2013-07-31

    multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 2011;40:67-75...submitted to the Faculty of the Endodontics Graduate Program Naval Postgraduate Dental School Uniformed Services University of the Health Sciences...in partial fulfillment of the requirements of the degree of Master of Science in Oral Biology June 2013 Naval Postgraduate Dental

  14. [Multidetector row CT in assessment of coronary artery calcification on hemodialisis].

    Science.gov (United States)

    Caro, P; Delgado, R; Dapena, F; Núñez, A

    2007-01-01

    Vascular calcification is a strong predictor of cardiovascular and all-cause mortality. Coronary artery calcification is more frequent, more extensive and progresses more rapidly in CKD than in general population. They are also considered a marker of coronary heart disease, with high prevalence and functional significance. It suggests that detection and surveillance may be worthwhile in general clinical practice. New non-invasive image techniques, like Multi-detector row CT, a type of spiral scanner, assess density and volume of calcification at multiple sites and allow quantitative scoring of vascular calcification using calcium scores analogous to those from electron-beam CT. We have assessed and quantified coronary artery calcification with 16 multidetector row CT in 44 patients on hemodialysis and their relationship with several cardiovascular risk factors. Coronary artery calcification prevalence was of 84 % with mean calcium score of 1580 +/- 2010 ( r 0-9844) with calcium score > 400 in 66% of patients. It was usually multiple, affecting more than two vessels in more than 50%. In all but one patient, left anterior descending artery was involved with higher calcium score level at right coronary artery. Advanced age, male, diabetes, smoking, more morbidity, cerebrovascular disease previous, and calcium-binders phosphate and analogous vitamin D treatment would seem to be associated with coronary artery calcification. Coronary artery calcification is very frequent and extensive, usually multiple and associated to modifiable risk factors in hemodialysis patients. Multi-detector-row CT seems an effective, suitable, readily applicable method to assess and quantify coronary artery calcification.

  15. Novel wearable and wireless ring-type pulse oximeter with multi-detectors.

    Science.gov (United States)

    Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh

    2014-01-01

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  16. Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors

    Directory of Open Access Journals (Sweden)

    Cheng-Yang Huang

    2014-09-01

    Full Text Available The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2. Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  17. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bin [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Dong Hun; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Seo, Hye Sun [Dept. of Internal Medicine, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-02-15

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  18. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  19. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  20. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  1. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  2. COMPUTING

    CERN Multimedia

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  3. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  4. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  5. Thoracoscopic lung segmentectomy simulated by a tailor-made virtual lung: computed bronchography and angiography.

    Science.gov (United States)

    Akiba, Tadashi; Morikawa, Toshiaki; Ohki, Takao

    2013-03-01

    We describe the benefits of simulating an anatomical lung segmentectomy using multidetector computed tomography bronchography and angiography (tailor-made virtual lung). Preoperative determination of the anatomical intersegmental plane is possible by visualizing the segmental bronchi and pulmonary vein branches. This advanced technique could be useful during thoracoscopic anatomical segmentectomy for lung cancer.

  6. Optimisation of coronary vascular territorial 3D echocardiographic strain imaging using computed tomography

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Fuchs, A; Weeke, P;

    2016-01-01

    Current echocardiographic assessments of coronary vascular territories use the 17-segment model and are based on general assumptions of coronary vascular distribution. Fusion of 3D echocardiography (3DE) with multidetector computed tomography (MDCT) derived coronary anatomy may provide a more acc...

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  8. COMPUTING

    CERN Document Server

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  9. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  10. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  11. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  12. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  13. COMPUTING

    CERN Multimedia

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  14. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

    Science.gov (United States)

    Kefer, Joelle M; Coche, Emmanuel; Vanoverschelde, Jean-Louis J; Gerber, Bernhard L

    2007-01-01

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting.

  15. Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kefer, Joelle M.; Vanoverschelde, Jean-Louis J.; Gerber, Bernhard L. [Cliniques Universitaires St. Luc UCL, Department of Cardiology, Brussels (Belgium); Coche, Emmanuel [Cliniques Universitaires St. Luc UCL, Department of Radiology, Brussels (Belgium)

    2007-01-15

    The purpose of this study was to assess the diagnostic accuracy of 16-slice multidetector-row computed tomography (MDCT) for detecting in-stent restenosis. Fifty patients with 69 previously implanted coronary stents underwent 16-slice MDCT before quantitative coronary angiography (QCA). Diagnostic accuracy of MDCT for detection of in-stent restenosis defined as >50% lumen diameter stenosis (DS) in stented and nonstented coronary segments >1.5-mm diameter was computed using QCA as reference. According to QCA, 18/69 (25%) stented segments had restenosis. In addition, 33/518 (6.4%) nonstented segments had >50% DS. In-stent restenosis was correctly identified on MDCT images in 12/18 stents, and absence of restenosis was correctly identified in 50/51 stents. Stenosis in native coronary arteries was correctly identified in 22/33 segments and correctly excluded in 482/485 segments. Thus, sensitivity (67% vs 67% p=1.0), specificity (98% vs 99%, p=0.96) and overall diagnostic accuracy (90% vs 97%, p=0.68) was similarly high for detecting in-stent restenosis as for detecting stenosis in nonstented coronary segments. MDCT has similarly high diagnostic accuracy for detecting in-stent restenosis as for detecting coronary artery disease in nonstented segments. This suggests that MDCT could be clinically useful for identification of restenosis in patients after coronary stenting. (orig.)

  16. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  17. Estudio del oído con TC Multidetector de 64 canales 64 - Detector CT findings in the study of the ear

    Directory of Open Access Journals (Sweden)

    María Lourdes Mallo

    2010-12-01

    Full Text Available El oído es una estructura anatómica compleja. Su estudio y comprensión resultan un reto diario para el radiólogo, siendo la tomografía computada una herramienta esencial para su estudio. La tomografía computada convencional con cortes finos en planos axiales y coronales permite una buena visualización de las diferentes estructuras. Sin embargo, se necesitan tiempos prolongados para su realización y posicionamientos incómodos o intolerables para muchos pacientes. Además la visualización de algunas de sus estructuras es limitada. La tomografía axial computada multidetector de 64 canales a nuestro medio permite optimizar el estudio de la compleja y pequeña anatomía del oído. La realización de adquisiciones volumétricas con cortes de 0,5 mm, con reconstrucciones multiplanares en los tres planos básicos, en planos curvos y reconstrucciones tridimensionales, hacen posible la visualización detallada de las estructuras en escasos segundos y en condiciones cómodas para el paciente. Nuestro propósito en este artículo es demostrar la utilidad de las reconstrucciones, particularmente en planos oblicuos, para identificar y analizar los diferentes reparos anatómicos del oído y alcanzar la visualización óptima de la anatomía relevante del hueso temporal.The ear is a complex anatomic structure. Its study and understanding represent a constant challenge for the radiologist. As a consequence the computed tomography becomes an essential tool for its examination. Conventional tomographic examination with both axial and coronal reconstruction of the image allows a satisfactory visualization of the different structures. However, the study requires long periods of time for its acquisition and uncomfortable or intolerable positions for the patients. Moreover, the characterization of some structures of the ear becomes limited. Sixty-four slice multidetector computed tomography allows the optimal study of the small and complex ear anatomy

  18. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  19. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  20. Performance comparison of multi-detector detection statistics in targeted compact binary coalescence GW search

    CERN Document Server

    Haris, K

    2016-01-01

    Global network of advanced Interferometric gravitational wave (GW) detectors are expected to be on-line soon. Coherent observation of GW from a distant compact binary coalescence (CBC) with a network of interferometers located in different continents give crucial information about the source such as source location and polarization information. In this paper we compare different multi-detector network detection statistics for CBC search. In maximum likelihood ratio (MLR) based detection approaches, the likelihood ratio is optimized to obtain the best model parameters and the best likelihood ratio value is used as statistic to make decision on the presence of signal. However, an alternative Bayesian approach involves marginalization of the likelihood ratio over the parameters to obtain the average likelihood ratio. We obtain an analytical expression for the Bayesian statistic using the two effective synthetic data streams for targeted search of non-spinning compact binary systems with an uninformative prior on...

  1. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  2. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with {sup 15}O-H{sub 2}O PET

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Naya, Masanao [Hokkaido University Graduate School of Medicine, Department of Cardiovascular Medicine, Sapporo (Japan); Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Sasaki, Tsukasa [Hokkaido University Hospital, Department of Radiology, Sapporo (Japan); Katoh, Chietsugu [Hokkaido University Faculty of Health Sciences, Sapporo (Japan); Shirato, Hiroki [Hokkaido University Graduate School of Medicine, Department of Radiation Medicine, Sapporo (Japan)

    2014-07-15

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against {sup 15}O-H{sub 2}O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFR{sub CT} in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  3. Three-dimensional volume-rendered multidetector CT imaging of the posterior inferior pancreaticoduodenal artery: its anatomy and role in diagnosing extrapancreatic perineural invasion

    Science.gov (United States)

    Giacomini, Craig; Brooke Jeffrey, R.; Willmann, Juergen K.; Olcott, Eric

    2013-01-01

    Abstract Extrapancreatic perineural spread in pancreatic adenocarcinoma contributes to poor outcomes, as it is known to be a major contributor to positive surgical margins and disease recurrence. However, current staging classifications have not yet taken extrapancreatic perineural spread into account. Four pathways of extrapancreatic perineural spread have been described that conveniently follow small defined arterial pathways. Small field of view three-dimensional (3D) volume-rendered multidetector computed tomography (MDCT) images allow visualization of small peripancreatic vessels and thus perineural invasion that may be associated with them. One such vessel, the posterior inferior pancreaticoduodenal artery (PIPDA), serves as a surrogate for extrapancreatic perineural spread by pancreatic adenocarcinoma arising in the uncinate process. This pictorial review presents the normal and variant anatomy of the PIPDA with 3D volume-rendered MDCT imaging, and emphasizes its role as a vascular landmark for the diagnosis of extrapancreatic perineural invasion from uncinate adenocarcinomas. Familiarity with the anatomy of PIPDA will allow accurate detection of extrapancreatic perineural spread by pancreatic adenocarcinoma involving the uncinate process, and may potentially have important staging implications as neoadjuvant therapy improves. PMID:24434918

  4. Renal safety in pediatric imaging: randomized, double-blind phase IV clinical trial of iobitridol 300 versus iodixanol 270 in multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Zo' o, Martin; Dosseur, Patrick Le [CHU Charles Nicolle, Radiology Department, Rouen (France); Hoermann, Marcus; Balassy, Csilla [AKH, Radiology Department, Vienna (Austria); Brunelle, Francis [Necker Hospital, Radiopediatry Department, Paris (France); Azoulay, Robin [Robert Debre Hospital, Radiopediatry Department, Paris (France); Pariente, Daniele [Kremlin-Bicetre Hospital, Radiopediatry Department, Kremlin-Bicetre (France); Panuel, Michel [Nord Hospital, Medical Imaging Department, Marseille (France)

    2011-11-15

    It is debated whether iso-osmolar and low-osmolar contrast media are associated with different incidences of contrast medium-induced nephropathy (CIN) in patients with renal insufficiency. To compare the incidence of CIN in children undergoing contrast-enhanced multidetector computer tomography (MDCT) with intravenous injection of low-osmolar (iobitridol, Xenetix {sup registered} 300) or an iso-osmolar (iodixanol, Visipaque {sup registered} 270) iodinated contrast medium. One hundred forty-six children with normal renal function were included in this multicenter trial and underwent contrast-enhanced MDCT. The primary endpoint was the relative change in creatinine clearance from 48 h pre- to 72 h postcontrast medium administration using a noninferiority analysis in the intent-to-treat (ITT, n = 128) and per protocol (n = 68) populations. Secondary endpoints were incidence of CIN, global image quality, diagnostic efficacy and clinical safety. In the ITT population, the noninferiority of iobitridol over iodixanol was demonstrated. CIN incidence was 4.8% (three cases) with iobitridol and 10.6% (seven cases) with iodixanol (not significant). No statistically significant differences were observed for the secondary endpoints. Comparable satisfactory safety profiles were confirmed for both contrast media, with no significant difference in the incidence of CIN in children with normal renal function. (orig.)

  5. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    El-Badrawy, Adel [Dept. of Radiology, Mansoura Faculty of Medicine, Mansoura (Egypt)], E-mail: adelelbadrawy@hotmail.com; Zeidan, Amany [Dept. of Thoracic Medicine, Mansoura Faculty of Medicine, Mansoura (Egypt); Ebrahim, Mohamed A. [Dept. of Medical Oncology, Mansoura Faculty of Medicine, Mansoura (Egypt)

    2012-07-15

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection.

  6. Are Hepatic Portal Venous System Components Distributed Equally in the Liver? A Multidetector Computerized Tomography Study

    Directory of Open Access Journals (Sweden)

    Bülent Yalçın

    2012-12-01

    Full Text Available Objective: We aimed to evaluate the relationships between the splenic index, right and left hepatic lobe volumes, diameters of splenic vein (SV, superior mesenteric vein (SMV and the portal vein (PV by Multidetector Computerized Tomography (MDCT. We also investigated indirect signs of portal venous flow pattern using these parameters.Material and Methods: Following their contrast thoracoabdominal and abdominal 64-MDCT examinations, the images of 100 cases (61 males and 39 females were evaluated retrospectively. For each case, the splenic index, total hepatic volume, left and right hepatic volumes were calculated on the post-contrast portal venous phase (50th sec images. Spearman correlation tests were carried out with the purpose of determining the relationships between the variables. Statistical significance level was set at p<0.005.Results: A statistically significant relation was demonstrated between the diameter of the SMV and right hepatic lobe volume (p<0.0001, and according to Pearson’s correlation analysis, a positive correlation of medium strength (r=0.36 was observed. A positive correlation was demonstrated between the diameter of the splenic vein and left hepatic lobe volume (r=0.36. Statistically significant relation between the diameters of the splenic vein and right hepatic lobe was not observed (p=0.62. A strong correlation between the left hepatic lobe volume and the splenic index (r=0.556 was observed.Conclusion: We observed a positive correlation and a significant relation between the diameter of the SMV and the right hepatic lobe, and a relation between the splenic vein and splenic index and both hepatic lobes. We believe that this situation is related to the streamline flow in the portal vein, and as demonstrated in the literature, the flow in the SMV is directed at the right lobe, whereas the splenic vein empties into the liver homogenously. Our study is the first study in the literature performed by multidetector CT

  7. Computed Tomography evaluation of maxillofacial injuries

    Directory of Open Access Journals (Sweden)

    V Natraj Prasad

    2017-01-01

    Full Text Available Background & Objectives: The maxillofacial region, a complex anatomical structure, can be evaluated by conventional (plain films, Tomography, Multidetector Computed Tomography, Three-Dimensional Computed Tomography, Orthopantomogram and Magnetic Resonance Imaging. The study was conducted with objective of describing various forms of maxillofacial injuries, imaging features of different types of maxillofacial fractures and the advantage of using Three- Dimensional Computed Tomography reconstructed image. Materials & Methods: A hospital based cross-sectional study was conducted among 50 patients during April 2014 to September 2016 using Toshiba Aquilion Prime 160 slice Multi Detector Computed Tomography scanner.Results: The maxillofacial fractures were significantly higher in male population (88% than female population (12 %. Road traffic accidents were the most common cause of injury others being physical assault and fall from height. It was most common in 31-40 years (26% and 21-30 (24% years age group. Maxillary sinus was the commonest fracture (36% followed by nasal bone and zygomatic bone (30%, mandible and orbital bones (28%. Soft tissue swelling was the commonest associated finding. Three dimensional images (3 D compared to the axial scans missed some fractures. However, the extension of the complex fracture lines and degree of displacement were more accurately assessed. Complex fractures found were Le fort (6% and naso-orbito-ethmoid (4% fractures.Conclusion: The proper evaluation of complex anatomy of the facial bones requires Multidetector Computed Tomography which offers excellent spatial resolution enabling multiplanar reformations and three dimensional reconstructions for enhanced diagnostic accuracy and surgical planning.

  8. Comparison of 4 cm Z-axis and 16 cm Z-axis multidetector CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Page, Mark; Nandurkar, Dee; Crossett, Marcus Peter; Stuckey, Stephen L.; Lau, Kenneth P.; Kenning, Nicholas; Troupis, John M. [Monash Medical Centre, Department of Diagnostic Imaging, Southern Health Network, Clayton, Victoria (Australia)

    2010-06-15

    The aim of the study was to compare 4 cm with 16 cm Z-axis coverage in the assessment of brain CT perfusion (CTP) using. 320 slice multidetector CT A retrospective non-randomised review of CTP performed on MD320 CT between September 2008 and January 2009 was undertaken. Two experienced readers reviewed the studies along with the 4 cm and 16 cm Z-axis CTP image data set. The outcome parameters assessed were the extent of the original finding, any additional findings and a change of diagnosis. 14 out of 27 patients were found to have abnormal CTP (mean age 58.1 years, 9 male). The 16 cm Z-axis increased the accuracy of the infarct core in 78% and ischaemic penumbra quantification in 100% of the cases. It also diagnosed additional infarcts in the same vascular territory in 28% of cases and in a different vascular territory in 14%. The increased field of view with MD320 better defines the true extent of the infarct core and ischaemic penumbra. It also identified other areas of infarction that were not identified on the 4 cm Z-axis. (orig.)

  9. FIASCO: a multidetector optimized for semiperipheral heavy ion collisions at Fermi energies

    Energy Technology Data Exchange (ETDEWEB)

    Bini, M.; Casini, G.; Olmi, A. E-mail: olmi@fi.infn.it; Poggi, G. E-mail: poggi@fi.infn.it; Stefanini, A.A.; Bardelli, L.; Bartoli, A.; Bidini, L.; Coppi, C.; Del Carmine, P.; Mangiarotti, A.; Maurenzig, P.R.; Pasquali, G.; Piantelli, S.; Poggi, S.; Taccetti, N.; Vanzi, E

    2003-12-11

    The FIASCO multidetector is a low-threshold apparatus, optimized for the investigation of peripheral to semi-central collisions in heavy ion reactions at Fermi energies. It consists of three types of detectors. The first detector layer is a shell of 24 position-sensitive Parallel Plate Avalanche Detectors (PPADs), covering about 70% of the forward hemisphere, which measure the velocity vectors of the heavy (Z > or approx. 10) reaction products. Below and around the grazing angle, behind the most forward PPADs, there are 96 {delta}E-E silicon telescopes (with thickness of 200 and 500 {mu}m, respectively); they are mainly used to measure the energy of the projectile-like fragment and to identify its charge and, via the time-of-flight of the PPADs, also its mass. Finally, behind most of the PPADs there are 158 (or 182, depending on the configuration) scintillation detectors, mostly of the phoswich type, which cover 25-30% of the forward hemisphere; they identify both light charged particles (Z=1,2) and intermediate mass fragments (3{<=}Z < or approx. 20), measuring also their time-of-flight.

  10. Pancreatic adenocarcinomas without secondary signs on multiphasic multidetector CT: association with clinical and histopathologic features

    Energy Technology Data Exchange (ETDEWEB)

    Tamada, Tsutomu; Ito, Katsuyoshi; Sone, Teruki; Kanki, Akihiko; Higaki, Atsushi; Hayashida, Minoru; Yamamoto, Akira [Kawasaki Medical School, Departments of Radiology, Kurashiki City, Okayama (Japan); Kanomata, Naoki [Kawasaki Medical School, Department of Pathology, Kurashiki City, Okayama (Japan)

    2016-03-15

    To determine the clinical, histopathologic and imaging features of pancreatic adenocarcinomas without secondary signs on dynamic CT. Seventy patients (mean age 70 years) with histologically proven pancreatic adenocarcinoma underwent preoperative contrast material-enhanced multiphasic multidetector CT before pancreatic resection. In each patient, clinical data including carbohydrate antigen 19-9, frequency of isoattenuating tumours, and presence of secondary signs and histopathologic findings such as tumour location, tumour stage, and microscopic infiltrative growth grade were evaluated. Ten tumours (14 %) were without secondary signs, and 60 (86 %) were with secondary signs. Tumours without and with secondary signs were located in the uncinate process in 5 (50 %) and 3 (5 %), head in 3 (30 %) and 29 (48 %), body in 2 (20 %) and 22 (37 %), and tail in 0 (0 %) and 6 (10 %), respectively (p =.001). The frequency of isoattenuating pancreatic adenocarcinomas without secondary signs was significantly higher than those with secondary signs (p = 0.034). The tumour stage of pancreatic adenocarcinomas without secondary signs was earlier than that in tumours with secondary signs (p = 0.041). Pancreatic adenocarcinomas without secondary signs is characterized by the presence of uncinate and isoattenuating tumours and earlier tumour stage compared to tumours with secondary signs. (orig.)

  11. Multidetector CT for congenital heart patients: what a paediatric radiologist should know

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jean-Francois; Rohnean, Adela; Sigal-Cinqualbre, Anne [Radiology Unit, Marie Lannelongue Hospital, Plessis-Robinson (France)

    2010-06-15

    Multidetector CT (MDCT) is increasingly used for imaging congenital heart disease (CHD) patients in addition to echocardiography, due to its ability to provide high quality three-dimensional images, giving a comprehensive evaluation of complex heart malformations. Using 4-slice or 16-slice CT, diagnostic information in CHD patients is limited to extra-cardiac anatomy, mainly the pulmonary arteries, aorta and venous connections. Due to high heart rates in babies however, coronary evaluation and intra-cardiac analysis were not reliable with the first generations of MDCT. Larger detector size with 64-slice CT and faster acquisition time, up to 75 ms for one slice, has progressively improved coronary and intra-cardiac visualization. Because radiation dose is the main concern, especially in children, every attempt to minimize dose whilst preserving image quality is important: the ALARA concept should always be applied in this population. The 80 kVp setting is now well accepted as a standard for more and more radiological teams involved in CT of children. Different acquisition strategies are now possible for childhood coronary imaging, using retrospective or even prospective gating. Using the latest technology, sub-mSv acquisitions are now attainable for scanning a whole thorax, providing a complete analysis of any 3-D cardiac malformation, including coronary artery course visualisation. This review will describe how technological developments have improved image quality with continuous reduction of radiation dose. (orig.)

  12. Synthetic streams in a Gravitational Wave inspiral search with a multi-detector network

    CERN Document Server

    K, Haris

    2014-01-01

    Gravitational Wave Inspiral search with a global network of interferometers when carried in a phase coherent fashion would mimic an effective multi-detector network with synthetic streams constructed by the linear combination of the data from different detectors. For the first time, we demonstrate that the two synthetic data streams pertaining to the two polarizations of Gravitational Wave can be derived prior to the maximum-likelihood analysis in a most natural way using the technique of singular-value-decomposition applied to the network signal-to-noise ratio vector. We construct the network matched filters in combined network plus spectral space which capture both the synthetic streams. We further show that the network LLR is then sum of the LLR of each synthetic stream. The four extrinsic parameters are mapped to the two amplitudes and two phases. The maximization over these is a straightforward approach closely linked to the single detector approach. Towards the end, we connect all the previous works rel...

  13. Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ki Ho; Choo, Ki Seok [Pusan National University Hospital, Department of Radiology, Medical Institute, Pusan (Korea); Lim, Soo Jin [Kim Hae Joong Ang Hospital, Department of Cardiology, Kimhae (Korea); Lee, Hyoung Doo; Park, Ji Ae; Jo, Min Jung [Pusan National University Hospital, Department of Paediatrics, Pusan (Korea); Sung, Si Chan; Chang, Yun Hee [Pusan National University Hospital, Department of Thoracic and Cardiovascular Surgery, Pusan (Korea); Jeong, Dong Wook [Pusan National University Hospital, Department of Family Medicine, Pusan (Korea); Kim, Siho [Dong-A University Hospital, Department of Thoracic and Cardiovascular Surgery, Pusan (Korea)

    2009-09-15

    Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. To compare MDCT with echocardiography in the evaluation of TAPVC. Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. MDCT can facilitate the diagnosis of TAPVC in certain cases. (orig.)

  14. Multidetector-row CT angiography of upper- and lower-extremity peripheral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Willmann, J.K.; Wildermuth, S. [Inst. of Diagnostic Radiology, Univ. Hospital Zurich, Zurich (Switzerland)

    2005-11-15

    With the introduction of multidetector-row CT (MDCT) technology indications for MDCT angiography have expanded to include assessment of the peripheral arteries of the upper and lower extremities. Combined with patient- and scanner-adjusted CT data acquisition and contrast medium application strategies, an accurate and reliable evaluation of the peripheral arteries of the upper and lower extremities is possible. MDCT angiography is cost-effective and accurate for detection of arterial stenosis and occlusion in patients with peripheral arterial disease (PAD). MDCT angiography allows postoperative assessment of peripheral arterial bypass grafts, including bypass graft stenosis and occlusion, as well as presence of aneurysms or arteriovenous fistulas. In addition, MDCT angiography is helpful in particular for visualization of arterial bypass grafts with a complicated extra-anatomical course. Furthermore, pre-operative peripheral vascular mapping can be performed by using MDCT angiography. Finally, due to the integration of MDCT scanners in many trauma centres, MDCT angiography is increasingly being used for assessment of traumatic arterial injuries. This article gives an overview of technical aspects of peripheral MDCT angiography, including scanning parameters, contrast medium application, image postprocessing and radiation exposure, and summarizes the most frequent acute and non-acute indications of MDCT angiography for assessment of the upper- and lower-extremity peripheral arteries. (orig.)

  15. Imaging of aortopulmonary collateral arteries with high-resolution multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Greil, Gerald F.; Hofbeck, Michael; Sieverding, Ludger [University of Tuebingen, Department of Pediatric Cardiology, Children' s Hospital, Tuebingen (Germany); Schoebinger, Max; Meinzer, Hans-Peter [German Cancer Research Center, Division of Medical and Biological Informatics, Heidelberg (Germany); Kuettner, Axel; Schaefer, Juergen F.; Dammann, Florian; Claussen, Claus D. [University of Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany)

    2006-06-15

    Precise visualization of the pulmonary vasculature is mandatory for adequate treatment of patients with pulmonary atresia and ventricular septal defect (PA-VSD). Aortopulmonary collateral arteries (APCs) can be visualized by selective injections of contrast agent in the catheterization laboratory. To evaluate multidetector CT (MDCT) and different image postprocessing methods for analysis of complex pulmonary blood supply in patients with PA-VSD. Eight patients (6 weeks to 27.8 years of age) with PA-VSD and APCs underwent MDCT and cardiac catheterization. Using multiplanar reformatting, volume rendering and semiautomatic segmentation algorithms, the aorta, pulmonary arteries and APCs were displayed. MDCT and cardiac catheterization were analyzed by two independent observers. MDCT accurately imaged central pulmonary arteries (n=8), aortopulmonary shunts (n=2), right ventricular to pulmonary artery conduits (n=2) and origin, course and intrapulmonary connections of APCs (n=25), compared to X-ray angiography. A high correlation was found between the MDCT vessel diameter measurements by two independent observers (n=70, r=0.96, P<0.01) and between MDCT and angiographic vessel diameter measurements (n=68, r=0.96, P<0.01). Using three-dimensional imaging software, a complex pulmonary blood supply can be non-invasively and accurately imaged with high-resolution MDCT. This technique may help to reduce the number of cardiac catheterizations or guide interventional or surgical therapy. (orig.)

  16. F IASCO: a multidetector optimized for semiperipheral heavy ion collisions at Fermi energies

    Science.gov (United States)

    Bini, M.; Casini, G.; Olmi, A.; Poggi, G.; Stefanini, A. A.; Bardelli, L.; Bartoli, A.; Bidini, L.; Coppi, C.; Del Carmine, P.; Mangiarotti, A.; Maurenzig, P. R.; Pasquali, G.; Piantelli, S.; Poggi, S.; Taccetti, N.; Vanzi, E.

    2003-12-01

    The F IASCO multidetector is a low-threshold apparatus, optimized for the investigation of peripheral to semi-central collisions in heavy ion reactions at Fermi energies. It consists of three types of detectors. The first detector layer is a shell of 24 position-sensitive Parallel Plate Avalanche Detectors (PPADs), covering about 70% of the forward hemisphere, which measure the velocity vectors of the heavy ( Z≳10) reaction products. Below and around the grazing angle, behind the most forward PPADs, there are 96 Δ E-E silicon telescopes (with thickness of 200 and 500 μm, respectively); they are mainly used to measure the energy of the projectile-like fragment and to identify its charge and, via the time-of-flight of the PPADs, also its mass. Finally, behind most of the PPADs there are 158 (or 182, depending on the configuration) scintillation detectors, mostly of the phoswich type, which cover 25-30% of the forward hemisphere; they identify both light charged particles ( Z=1,2) and intermediate mass fragments (3⩽ Z≲20), measuring also their time-of-flight.

  17. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  18. Optimal iodine dose for 3-dimensional multidetector-row CT angiography of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Tomoaki, E-mail: ichikawa@yamanashi.ac.jp [Department of Radiology, University of Yamanashi, Yamanashi (Japan); Motosugi, Utaroh; Morisaka, Hiroyuki; Sou, Hironobu; Onohara, Kojiro; Sano, Katsuhiro; Araki, Tsutomu [Department of Radiology, University of Yamanashi, Yamanashi (Japan)

    2012-09-15

    Purpose: To clarify the optimal iodine dose of contrast material for 3-dimensional multidetector-row CT angiography (3D-MDCTA) of the venous vasculature of the liver using volume rendering technique. Materials and methods: This study included 103 patients who were randomly assigned to 5 contrast-enhanced MDCT protocol groups with different body-weight-tailored doses of contrast material: 500, 600, 630, 650, and 700 mgI/kg body weight. The arterial, portal, and hepatic parenchymal phases were obtained to evaluate enhancement values of the aorta, portal vein, and hepatic vein. Visualization of the portal and hepatic veins on the volume-rendering images of 3D-MDCTA was evaluated using a 5-point grade. Dunnett's test was used to compare the mean enhancement value and mean grades of image quality (700 mgI/kg dose group was control). Results: The mean enhancement values of portal and hepatic vein in the group with 500 and 600 mgI/kg were significantly lower than those of the control group. During visual assessment, a significantly lower mean grades were observed in 500 mgI/kg groups for the portal vein, and 500 and 600 mgI/kg groups for hepatic vein. There were no significant intergroup differences in mean enhancement values and visual assessment among the groups using 630 mgI/kg or more. Conclusion: Iodine doses of 630 mgI/kg was recommended for 3D-MDCTA.

  19. Role of curved planar reformations using multidetector spiral CT in diagnosis of pancreatic and peripancreatic diseases

    Institute of Scientific and Technical Information of China (English)

    Jing-Shan Gong; Jian-Min Xu

    2004-01-01

    AIM: To investigate the role of curved planar reformations using multidetector spiral CT (MSCT) in diagnosis of pancreatic and peripancreatic diseases.METHODS: From October 2001 to September 2003, 47consecutive patients with pancreatic or peripancreatic diseases, which were confirmed by operation, endoscopic retrograde cholangiopancreatography and clinical follow-up,were enrolled in this study. CT scanning was performed at a MSCT with four rows of detector. A set of images with an effective thickness of 1.0-2.0 mm and a gap of 0.5-1.0 mm(50% overlap) were acquired in all patients for postprocessing. Curved planar reformations were carried out by drawing a curved line on transverse source images, coronal or sagittal multiplanar reformations according to certain anatomic structures (such as cholangiopancreatic ducts or peripancreatic vessels) and the position of lesion.RESULTS: With thin collimation, MSCT could acquire highquality curved planar reformations to display the profile of the whole pancreas, to trace the cholangiopancreatic ducts and peripancreatic vessels, and to show the relationship of lesions with pancreas and peripancreatic anatomic structures in one curved plane, which facilitates diagnosis and rapid communication of diagnostic information with referring physicians.CONCLUSION: MSCT with thin collimation could be used to create high-quality curved planar reformations in evaluating pancreatic and peripancreatic diseases with pertinent anatomic information and relative pathologic signs to facilitate the diagnosis and enhance communication with the referring physician. Curved planar reformations can serve as supplements for transverse images in diagnosis and management of pancreatic and peripancreatic diseases.

  20. Multidetector CT appearance of the pelvis after cesarean delivery: normal and abnormal acute findings.

    Science.gov (United States)

    Gui, Benedetta; Danza, Francesco Maria; Valentini, Anna Lia; Laino, Maria Elena; Caruso, Alessandro; Carducci, Brigida; Rodolfino, Elena; Devicienti, Ersilia; Bonomo, Lorenzo

    2016-01-01

    Cesarean section (CS) may have several acute complications that can occur in the early postoperative period. The most common acute complications are hematomas and hemorrhage, infection, ovarian vein thrombosis, uterine dehiscence and rupture. Pelvic hematomas usually occur at specific sites and include bladder flap hematoma (between the lower uterine segment and the bladder) and subfascial or rectus sheath hematoma (rectus sheath or prevescical space). Puerperal hemorrhage can be associated with uterine dehiscence or rupture. Pelvic infections include endometritis, abscess, wound infection, and retained product of conception. Radiologists play an important role in the diagnosis and management of postoperative complications as a result of increasing use of multidetector CT in emergency room. The knowledge of normal and abnormal postsurgical anatomy and findings should facilitate the correct diagnosis so that the best management can be chosen for the patient, avoiding unnecessary surgical interventions and additional treatments. In this article we review the surgical cesarean technique and imaging CT technique followed by description of normal and abnormal post-CS CT findings.

  1. Contrast extravasation into an acute spontaneous intracerebral hematoma: multidetector CT angiographic findings and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Eun; Yu, Hyeon; Baik, Hye Won; Lee, Hwa Yeon; Kwak, Byung Kook; Lee, Jong Beum; Kim, Yang Soo; Lee, Yong Chul [Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2007-05-15

    The purpose of this study was to evaluate multidetector row CT (MDCT) angiographic findings and their clinical significance for contrast extravasation into a spontaneous intracerebral hematoma (ICH). MDCT angiographic studies and clinical records of 115 patients with spontaneous ICH were retrospectively reviewed. Cases were divided into two groups according to the presence or absence of contrast extravasation. The cases in the two groups were compared to determine the differences in radiological and clinical findings. The contrast extravasation group was divided into two subgroups according to radiological findings as follows: single or multiple dot-like contrast extravasation (Type A) and beaded-tubular (with or without dot-like extravasation) contrast extravasation (Type B). Contrast extravasation was seen in 38 patients (33%). It was associated with a larger hematoma volume, more frequent intraventricular hemorrhage (IVH) and subarachnoid hemorrhage (SAH), a shorter time interval from onset to the time of the CT scan, lower Glasgow coma scale (GCS), and a higher mortality rate. Type A and B contrast extravasation were observed in 16 (42%) and 22 (58%) patients, respectively. The rate of IVH and the clinical outcome of patients with Type B showed a significant correlation. Two types of contrast extravasation into an ICH show a significant difference in the rate of IVH and in clinical outcome. Detecting the presence of contrast extravasation and classifying them according to the morphologic patterns are important in predicting a prognosis.

  2. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Chalumeau-Lemoine, Ludivine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine_khalil@yahoo.fr [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Pathological Angiogenesis and Vessel Normalization, Center for Interdisciplinary Research in Biology, CNRS UMR 7241/INSERM U1050, Collège de France, Paris (France); Prigent, Hélène [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Carette, Marie-France [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Fartoukh, Muriel [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Parrot, Antoine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France)

    2013-11-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting.

  3. Clinical and multidetector CT follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Min; Park, Kwang Bo; Kim, Keon Ha; Jeon, Pyoung; Shin, Sung Wook; Park, Hong Suk; Do, Young Soo (Dept. of Radiology and the Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kbparksmc@skku.edu; Kim, Dong-Ik; Kim, Young-Wook (Div. of Vascular Surgery, Dept. of Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of))

    2011-10-15

    Background: There are very few reports regarding the use of 3D rotational angiography (3D RA) in embolization of renal artery aneurysms (RAAs). No valuable data have been reported on the follow-up result of coil embolization for RAAs on computed tomography (CT). Purpose: To evaluate the clinical and multidetector computed tomography (MDCT) follow-up results of renal artery aneurysms treated by detachable coil embolization using 3D RA. Material and Methods: Six patients diagnosed with RAAs were included. Five patients underwent detachable coil embolization. Five patients underwent 3D RA and the parameters used for planning endovascular treatment obtained by 2D CT, reformatted 3D CT angiography (3D CTA), 2D digital subtraction angiography (2D DSA) and 3D RA were compared. The post embolization MDCT follow-up findings were analyzed retrospectively. Results: The technical success rate for detachable coil embolization was 40%. The 3D CTA showed the dome-to-neck ratio (DNR) and tangential view of the renal artery aneurysm in five patients (83.3%) and the 2D CT showed it in four (66.7%). An optimal working angle assessment could not be obtained on the 2D CT and 3D CTA. The 3D RA showed the DNR, tangential view, and optimal working angle in all patients. Renal infarction occurred in three patients and Postprocedural hypertension developed in two patients during the follow-up period. Conclusion: The 3D RA was useful in preoperative determination of adequate working angle for detachable coil embolization of RAAs. Late complications of detachable coil embolization for RAAs were renal infarction and hypertension

  4. Tomografía Computada Multidetector en el diagnóstico de la pseudocoartación de aorta: Reporte de dos casos y revisión de la literatura Multidetector CT in diagnosis of aortic pseudocoarctation: Two reported cases and revised literature

    Directory of Open Access Journals (Sweden)

    Martín Mela

    2011-06-01

    Full Text Available La pseudocoartación aórtica es una rara anomalía que consiste en una elongación tortuosa con acodadura de la arteria aorta que involucra la región distal del cayado y la porción descendente proximal, típicamente relacionada al sitio de inserción del ligamento arterioso. No suelen existir manifestaciones clínicas asociadas, por lo que el diagnóstico habitualmente es incidental mediante estudios de imágenes. Entre ellos, se destacan la angio Tomografía Computada Multidetector (angio TCMD y la Resonancia Magnética (RM. Se diferencia de la verdadera coartación aórtica por su morfología y por la ausencia de obstrucción hemodinámicamente significativa. En el presente artículo revisamos los aspectos imagenológicos utilizando TCMD en dos pacientes a los cuales se les diagnosticó la pseudocoartación, sin ser ésta la patología sospechada al momento de indicar el estudio. La TCMD permite realizar un diagnóstico apropiado mostrando las características diferenciales con otras anomalías aórticas.The aortic pseudocoarctation is a rare anomaly characterized by a tortuous elongation with kink aorta which compromises the distal portion of the aortic arch and the proximal descending portion, typically related to the insertion site of arterious ligament. Usually, there are no associated symptoms so the diagnosis is generally incidental with imaging such as Multidetector Computed Tomography (MDCT or Magnetic Resonance Imaging (MRI. It differs from the true aortic coarctaction in their morphology and in the absence of hemodynamically significant obstruction. In this paper we review the imagenologic features using MDCT in two patients who were diagnosed with pseudocoartaction, which was not suspected before performing the study. MDCT allows a proper diagnosis showing differential characteristics with other aortic anomalies.

  5. Calcified pulmonary thromboembolism in a child with sickle cell disease: value of multidetector CT in patients with acute chest syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Staser, Jonathan A. [Indiana University Medical Center, Department of Radiology, Indianapolis, IN (United States); Alam, Tariq [Medical College of Ohio, Department of Radiology, Toledo, OH (United States); Applegate, Kimberly [Indiana University Medical Center, Sections of Pediatric Radiology and Health Services Research, Indianapolis, IN (United States); Indiana University Medical Center, Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States)

    2006-06-15

    The incidence of pulmonary embolism in children is not clearly known, but is believed to be low. Risk factors for pulmonary thromboembolism include central venous catheter, malignancy, surgery, infection, trauma, and congenital hypercoagulable disorders. Children with sickle cell disease are prothrombotic and are at an increased risk of thromboembolism. The incidence of this event is unknown because these children are often not thoroughly imaged. We report here a case of a calcified pulmonary thromboembolism in a child with sickle cell disease and emphasize the use of multidetector CT in detection of pulmonary thromboembolism in children with sickle cell disease. (orig.)

  6. Multidetector CT Findings and Differential Diagnoses of Malignant Pleural Mesothelioma and Metastatic Pleural Diseases in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung [Department of Radiology, Gachon University Gil Medical Center, Incheon 21565 (Korea, Republic of); Kim, Jeung Sook [Department of Radiology, Dongguk University Ilsan Hospital, Goyang 10326 (Korea, Republic of); Lee, Kyung Won [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620 (Korea, Republic of); Yi, Chin A [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of); Koo, Jin Mo [Department of Radiology, Seoul National University College of Medicine, Seoul 03080 (Korea, Republic of); Jung, Soon-Hee [Department of Pathology, Yonsei University Wonju College of Medicine, Wonju 26426 (Korea, Republic of)

    2016-11-01

    To compare the multidetector CT (MDCT) features of malignant pleural mesothelioma (MPM) and metastatic pleural disease (MPD). The authors reviewed the MDCT images of 167 patients, 103 patients with MPM and 64 patients with MPD. All 167 cases were pathologically confirmed by sonography-guided needle biopsy of pleura, thoracoscopic pleural biopsy, or open thoracotomy. CT features were evaluated with respect to pleural effusion, pleural thickening, invasion of other organs, lung abnormality, lymphadenopathy, mediastinal shifting, thoracic volume decrease, asbestosis, and the presence of pleural plaque. Pleural thickening was the most common CT finding in MPM (96.1%) and MPD (93.8%). Circumferential pleural thickening (31.1% vs. 10.9%, odds ratio [OR] 3.670), thickening of fissural pleura (83.5% vs. 67.2%, OR 2.471), thickening of diaphragmatic pleura (90.3% vs. 73.4%, OR 3.364), pleural mass (38.8% vs. 23.4%, OR 2.074), pericardial involvement (56.3% vs. 20.3%, OR 5.056), and pleural plaque (66.0% vs. 21.9%, OR 6.939) were more frequently seen in MPM than in MPD. On the other hand, nodular pleural thickening (59.2% vs. 76.6%, OR 0.445), hilar lymph node metastasis (5.8% vs. 20.3%, OR 0.243), mediastinal lymph node metastasis (10.7% vs. 37.5%, OR 0.199), and hematogenous lung metastasis (9.7% vs. 29.2%, OR 0.261) were less frequent in MPM than in MPD. When we analyzed MPD from extrathoracic malignancy (EMPD) separately and compared them to MPM, circumferential pleural thickening, thickening of interlobar fissure, pericardial involvement and presence of pleural plaque were significant findings indicating MPM than EMPD. MPM had significantly lower occurrence of hematogenous lung metastasis, as compared with EMPD. Awareness of frequent and infrequent CT findings could aid in distinguishing MPM from MPD.

  7. Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Radiology, Genoa (Italy); Origgi, Daniela; Palorini, Federica [Istituto Europeo di Oncologia, Department of Medical Physics, Milan (Italy); Matranga, Domenica [University of Palermo, Department of Sciences for Health Promotion and Mother and Child Care ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [University of Palermo, Department of Medical and Forensic Biopathology and Biotechnologies, Section of Radiology, Palermo (Italy)

    2015-05-01

    Multidetector CT (MDCT) scanners have contributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition parameters of CT examinations in three age groups (1-5, 6-10, 11-15 years) for studies of head, chest and abdomen. The dosimetric results were reported in terms of third-quartile volumetric CT dose index (CTDI{sub vol}) (mGy), size-specific dose estimate (SSDE) (mGy), dose length product (DLP) (mGy cm), and total DLP for multiphase studies. These results were compared with paediatric European and adult Italian published data. A multivariate analysis assessed the association of CTDI{sub vol} with patient characteristics and scanning modalities. We collected data from 993 MDCT examinations performed at 25 centres. For age groups 1-5 years, 6-10 years and 11-15 years, the CTDI{sub vol}, DLP and total DLP values were statistically significantly below the values observed in our analogous national survey in adults, although the difference decreased with increasing age. CTDI{sub vol} variability among centres was statistically significant (variance = 0.07; 95% confidence interval = 0.03-0.16; P < 0.001). This study reviewed practice in Italian centres performing paediatric imaging with MDCT scanners. The variability of doses among centres suggests that the use of standardised CT protocols should be encouraged. (orig.)

  8. Evaluation of angiogenesis in colorectal carcinoma with multidetector-row CT multislice perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Feng Shiting, E-mail: fst1977@163.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Sun Canhui, E-mail: canhuisun@sina.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Li Ziping, E-mail: liziping163@tom.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Mak, Henry Ka-Fung, E-mail: makkf@hkucc.hku.h [Department of Diagnostic Radiology, University of Hong Kong, Hong Kong (China); Peng Zhenpeng, E-mail: ppzhen@21cn.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Guo Huanyi, E-mail: guohuanyi@163.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Meng Quanfei, E-mail: mzycoco@gmail.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China)

    2010-08-15

    To evaluate the correlation between 64 multidetector-row CT (64MDCT) perfusion imaging in colorectal carcinoma and microvessel density (MVD) and vascular endothelial growth factor (VEGF), 64MDCT perfusion imaging was performed in 33 patients with pathologically verified colorectal carcinoma. These images were analyzed with perfusion functional software, and time-density curves (TDC) were created for the region of interest (ROI) encompassing the tumor, the target artery and vein. The individual perfusion maps generated indicated blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability-surface area product (PS). MVD and VEGF were evaluated by immunohistochemical staining with anti-CD34 and anti-VEGF, respectively. Correlations between MVD or VEGF with CT perfusion parameters and clinicopathological factors (Dukes' stages, invasion depth, and lymph node and liver metastasis) were also investigated. MVD in the colorectal carcinoma was 22.61 {+-} 9.01 per x200 field. The scores obtained for VEGF expression were 4.15 {+-} 1.09. VEGF staining was positive in 25 of 29 tumors (86.2%). There was no significant correlation between the presence of MVD, VEGF expression and clinicopathological factors (P > 0.05). There was also no correlation between MVD, VEGF expression, and any dynamic CT parameters (P > 0.05). The BV and MTT were significantly higher in tumors demonstrating serous coat invasion than in those without it (t = -2.63, -2.24, P = 0.0137, 0.0331, respectively). BV was also significantly correlated with tumor size (r = 0.41, P = 0.02). Neither BF nor PS was correlated with clinicopathological factors. In conclusion, 64MDCT perfusion imaging, MVD, and VEGF may reflect angiogenic activity, but no significant correlation among these factors.

  9. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E. [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, 71003 Iraklion, Crete (Greece); Department of Medical Physics, University Hospital of Iraklion, P.O. Box 1352, 71003 Iraklion, Crete (Greece); Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, 71003 Iraklion, Crete (Greece); Department of Medical Physics, University Hospital of Iraklion, P.O. Box 1352, 71003 Iraklion, Crete (Greece)

    2010-12-15

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  10. Bronchial anatomy of left lung: a study of multi-detector row CT.

    Science.gov (United States)

    Zhao, Xinya; Ju, Yuanrong; Liu, Cheng; Li, Jianfeng; Huang, Min; Sun, Jian; Wang, Tao

    2009-02-01

    Familiarity with prevailing pattern and variations in the bronchial tree is not only essential for the anatomist to explain bronchial variation in bronchial specimens, but also useful for guiding bronchoscopy and instructing pulmonary segmental resection. The purpose of this study was designed to demonstrate various branching patterns of left lung with 3D images, with special attention given to identify the major types at transverse thin-section CT. Two hundred and sixteen patients with routine thorax scans were enrolled. The images of bronchial tree, virtual bronchoscopy were reconstructed using post-processing technique of multi-detector row CT. We attempted to classify the segmental bronchi by interpreting the post-processing images, and identified them in transverse thin-section CT. Our results showed that the segmental bronchial ramifications of the left superior lobe were classified into three types mainly, i.e., common stem of apical and posterior segmental bronchi (64%, 138/216); trifurcation (23%, 50/216); common stem of apical and anterior segmental bronchi (10%, 22/216), and they could be identified at two typical sections of transverse thin-section CT. There were two major types in left basal segmental bronchi, i.e., bifurcation (75%, 163/216), trifurcation (18%, 39/216), and they could also be identified at two typical sections of transverse thin-section CT. In conclusion, our study have offered simplified branching patterns of bronchi and demonstrated various unusual bronchial branching patterns perfectly with 3D images, and have also revealed how to identify the main branching patterns in transverse thin-section CT.

  11. Correlation between Acute Coronary Syndrome Classification and Multi-detector CT Characterization of Plaque

    Institute of Scientific and Technical Information of China (English)

    Zhi-guo Wang; Lu-yue Gai; Jing-jing Gai; Ping Li; Xia Yang; Qin-hua Jin; Yun-dai Chen; Zhi-jun Sun; Zhi-wei Guan

    2011-01-01

    Objective To determine if multi-detector CT (MDCT) characterization of plaque is correlated with the classification of acute coronary syndrome (ACS). Methods Altogether 1900 patients were examined by MDCT from December 2007 to May 2009,of whom 95 patients fulfilled the criteria of ACS. Those patients were divided into the discrete plaque group (n=61) and diffuse plaque group (n=34) based on the findings in MDCT. The clinical diagnosis of ACS and CT results were analyzed, including segment stenosis score, segment involvement score, 3-vessel plaque score, left main score, calcification score, and remodeling index. The incidences of major adverse cardiac events in follow-up period were also recorded.Results The patients of the diffuse plaque group were older than those of the discrete plaque group (P<0.0001). The diffuse plaque group presented more cases of hypertension, peripheral artery disease, diabetes, and heart failure than discrete plaque group (all P<0.05). All the 5 patients with ST-segment elevation myocardial infarction were found in discrete plaque group. The segment stenosis score of the discrete plaque group was lower than that of the diffuse plaque group (5.15+3.55 vs. 14.91+5.37, P<0.001). The other four scores demonstrated significant inter-group difference as well (all P<0.05). The remodeling index of the discrete plaque group was higher (1.12+0.16 vs. 0.97+0.20, P<0.05). Follow-up data showed that major adverse cardiac events occurred more frequently in diffuse plaque group than in discrete group (29.41% vs.11.48%, P=0.0288).Conclusions Characteristics of discrete and diffuse plaques may be significandy different among different classes of ACS. The diffuse plaque may present higher risk, correlated to higher mortality. The diagnosis of discrete and diffuse plaques by MDCT would provide a new insight into the prognosis and treatment of ACS.

  12. Multi-detector CT angiography for lower gastrointestinal bleeding: Can it select patients for endovascular intervention?

    Science.gov (United States)

    Foley, P T; Ganeshan, A; Anthony, S; Uberoi, R

    2010-02-01

    This is a retrospective review of the results at our institution of using multi-detector CT angiography (CTA) to localise lower gastrointestinal (GI) bleeding. We hypothesised that in our patient population: (i) CTA was unlikely to demonstrate bleeding in patients who were haemodynamically stable; (ii) in haemodynamically unstable patients in whom CTA was undertaken, the results could be used to select patients who would benefit from catheter angiography; and (iii) in haemodynamically unstable patients in whom CTA was undertaken, a subgroup of patients could be identified who would benefit from primary surgical treatment, avoiding invasive angiography completely. A retrospective review was conducted of the clinical records of all patients undergoing CTA for lower GI haemorrhage at our institution between 1 January 2005 and 30 June 2007. Out of the 20 patients examined, 10 had positive CTAs demonstrating the bleeding site. Nine were haemodynamically unstable at the time of the study. Four patients with positive CT angiograms were able to be treated directly with surgery and avoided invasive angiography. Ten patients had negative CTAs. Four of these were haemodynamically unstable, six haemodynamically stable. Only one required intervention to secure haemostasis, the rest stopped spontaneously. No haemodynamically stable patient who had a negative CTA required intervention. CTA is a useful non-invasive technique for localising the site of lower GI bleeding. In our patient population, in the absence of haemodynamic instability, the diagnostic yield of CTA was low and bleeding was likely to stop spontaneously. In haemodynamically unstable patients, a positive CTA allowed patients to be triaged to surgery or angiography, whereas there was a strong association between a negative CTA and spontaneous cessation of bleeding.

  13. Investigation of acute lower gastrointestinal bleeding with 16- and 64-slice multidetector CT.

    Science.gov (United States)

    Lee, S; Welman, C J; Ramsay, D

    2009-02-01

    We evaluated the usefulness of 16- and 64-slice multidetector CT (MDCT) in the detection of a bleeding site in acute lower gastrointestinal tract (GIT) haemorrhage by conducting a retrospective study of cases of presumed acute lower GIT haemorrhage imaged with CT in two teaching hospitals in an 11-month period. The patients underwent contrast enhanced CT using either a 16 or 64 MDCT. No oral contrast was used. One hundred milliliters of non-ionic intravenous contrast agent was injected at 4.5 mL/s, followed by a 60 mL saline flush at 4 mL/s through a dual head injector. Images were acquired in arterial phase with or without non-contrast and portal phase imaging with 16 x 1.5 mm or 64 x 0.625 mm collimation. Active bleeding was diagnosed by the presence of iodinated contrast extravasation into the bowel lumen on arterial phase images with attenuation greater than and distinct from the normal mucosal enhancement or focal pooling of increased attenuation contrast material within a bowel segment on portal-venous images. Further management and final diagnosis was recorded. Fourteen patients and 15 studies were reviewed. CT detected and localized a presumed bleeding site or potential causative pathology in 12 (80%) of the patients. Seven of these were supported by other investigations or surgery, while five were not demonstrated by other modalities. Eight patients had mesenteric angiography, of which only four corroborated the site of bleeding. CT did not detect the bleeding site in three patients, of which two required further investigation and definitive treatment. We propose that MDCT serves a useful role as the initial rapid investigation to triage patients presenting with lower GIT bleeding for further investigation and management.

  14. Multidetector CT findings and differential diagnoses of malignant pleural mesothelioma and metastatic pleural diseases in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of); Kim, Jeung Sook [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang (Korea, Republic of); Lee, Kyung Won [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Yi, Chin A [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Koo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Soon Hee [Dept. of Pathology, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2016-07-15

    To compare the multidetector CT (MDCT) features of malignant pleural mesothelioma (MPM) and metastatic pleural disease (MPD). The authors reviewed the MDCT images of 167 patients, 103 patients with MPM and 64 patients with MPD. All 167 cases were pathologically confirmed by sonography-guided needle biopsy of pleura, thoracoscopic pleural biopsy, or open thoracotomy. CT features were evaluated with respect to pleural effusion, pleural thickening, invasion of other organs, lung abnormality, lymphadenopathy, mediastinal shifting, thoracic volume decrease, asbestosis, and the presence of pleural plaque. Pleural thickening was the most common CT finding in MPM (96.1%) and MPD (93.8%). Circumferential pleural thickening (31.1% vs. 10.9%, odds ratio [OR] 3.670), thickening of fissural pleura (83.5% vs. 67.2%, OR 2.471), thickening of diaphragmatic pleura (90.3% vs. 73.4%, OR 3.364), pleural mass (38.8% vs. 23.4%, OR 2.074), pericardial involvement (56.3% vs. 20.3%, OR 5.056), and pleural plaque (66.0% vs. 21.9%, OR 6.939) were more frequently seen in MPM than in MPD. On the other hand, nodular pleural thickening (59.2% vs. 76.6%, OR 0.445), hilar lymph node metastasis (5.8% vs. 20.3%, OR 0.243), mediastinal lymph node metastasis (10.7% vs. 37.5%, OR 0.199), and hematogenous lung metastasis (9.7% vs. 29.2%, OR 0.261) were less frequent in MPM than in MPD. When we analyzed MPD from extrathoracic malignancy (EMPD) separately and compared them to MPM, circumferential pleural thickening, thickening of interlobar fissure, pericardial involvement and presence of pleural plaque were significant findings indicating MPM than EMPD. MPM had significantly lower occurrence of hematogenous lung metastasis, as compared with EMPD. Awareness of frequent and infrequent CT findings could aid in distinguishing MPM from MPD.

  15. Is it possible that this patient is asymptomatic? The role of multidetector ct angiography in detection of ulcerated plaques in patients with asymptomatic carotid stenosis: Case report

    Directory of Open Access Journals (Sweden)

    Tanasković Slobodan

    2015-01-01

    Full Text Available Introduction. Although intervention in patients with symptomatic carotid disease is generally accepted as beneficial, the management of asymptomatic disease is still controversial. We wanted to introduce and discuss treatment options in a patient with asymptomatic carotid stenosis and high embolic potential lesions of common and internal carotid artery detected by multidetector computed tomography (MDCT. Case Outline. A 78-year-old female patient was admitted to our institution for diagnostics and surgical treatment of asymptomatic high-grade carotid stenosis. Upon admission, color duplex ultrasonography of the carotid arteries revealed the left common carotid artery (CCA stenosis of 50% and the ipsilateral internal carotid artery (ICA stenosis of 60%, while the right CCA was narrowed by 60% and the ipsilateral ICA by 80%. Because of the left subclavian artery (LSA occlusion, also described by ultrasonography, MDCT angiography was performed to assess arterial morphology for possible angioplasty. In addition to LSA occlusion, MDCT angiography surprisingly revealed significant left CCA (>80% and ICA (>70% narrowing by ulcerated plaques with high embolic potential. Surgical treatment of the left CCA and ICA was indicated and Dacron® tubular graft interposition was performed. The postoperative course was uneventful and the patient was discharged from the Institute on the third postoperative day. After the six-month follow-up the patient was doing well with well-preserved graft patency. Conclusion. Although color duplex ultrasonography is reliable and safe imaging modality in carotid stenosis diagnosis, MDCT angiography plays a significant role in patients with asymptomatic carotid stenosis since plaques with high embolic potential could be detected, which, if left untreated, could have severe neurological ischemic consequences. [Projekat Ministarstva nauke Republike Srbije, br. 41002

  16. Quantitative assessment of first-pass perfusion using a low-dose method at multidetector CT in oesophageal squamous cell carcinoma: Correlation with VEGF expression

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.-W. [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China) and Sichuan Province Key Laboratory of Medical Imaging and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637000 (China); Yang, Z.-G., E-mail: yangzg1117@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Chen, H.-J. [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li, Y.; Tang, S.-S.; Yao, J.; Dong, Z.-H. [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); He, D. [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2012-08-15

    Aim: To investigate the correlation between vascular endothelial cell growth factor (VEGF) expression and first-pass perfusion parameters at multidetector computed tomography (MDCT) using a low-dose technique, and to determine how to discriminate VEGF positivity from VEGF negativity by perfusion CT in oesophageal squamous cell carcinomas. Materials and methods: Thirty-two patients with oesophageal squamous cell carcinomas underwent first-pass perfusion with 64-section MDCT at 50 mAs. Perfusion parameters, including perfusion, peak enhanced density (PED), time to peak (TTP), and blood volume (BV), were measured. Postoperative specimens were assessed for VEGF expression. Correlation tests were performed to determine the associations between each CT perfusion parameter and VEGF expression. The cut-off values of perfusion parameters were obtained statistically to discriminate VEGF positivity from VEGF negativity. Results: Mean perfusion, PED, TTP, and BV were 38.47 {+-} 30.26 ml/min/ml, 24.68 {+-} 9.65 HU, 28.35 {+-} 9.03 s, and 11.82 {+-} 6.06 ml/100 g, respectively. PED or BV were significantly higher in the VEGF-positive group than in the VEGF-negative group (all p < 0.05), but no significant difference in perfusion or TTP was found between the VEGF-positive and VEGF-negative groups (all p > 0.05). In VEGF positivity, PED and BV were correlated with VEGF expression (r = 0.576 and 0.765, respectively; all p < 0.05), whereas perfusion and TTP were not (r = 0.361 and 0.239, respectively; all p > 0.05). A threshold of BV (10.23 ml/100 g) achieved a sensitivity of 94.4%, and a specificity of 92.9% for discriminating VEGF positivity from VEGF negativity. Conclusion: BV could reflect tumour VEGF expression, and could be an indicator for evaluating angiogenesis in oesophageal tumours.

  17. Multi-detector CT enterography with iso-osmotic mannitol as oral contrast for detecting small bowel disease

    Institute of Scientific and Technical Information of China (English)

    Lian-He Zhang; Shi-Zheng Zhang; Hong-Jie Hu; Min Gao; Ming Zhang; Qian Cao; Qiao-wei Zhang

    2005-01-01

    AIM: To assess the feasibility and usefulness of multi-detector CT enterography with orally administered iso-osmotic mannitol as negative contrast in demonstrating small bowel disease.METHODS: Thirteen volunteers and 38 patients with various kinds of small bowel disease were examined. We administered about 1 500 mL iso-osmotic mannitol as negative contrast agent and then proceeded with helical CT scanning on a Siemens Sensation 16 scanner. All volunteers and patients were interviewed about their tolerance of the procedure. Two radiologists postprocessed imaging data with MPR, thin MIP, VRT and INSPACE when necessary and then interpreted the scans,and adequacy of luminal distention was evaluated on a four-point scale. Demonstration of features of various kinds of small bowel disease was analyzed.RESULTS: The taste of iso-osmotic mannitol is good (slightly sweet) and acceptable by all. Small bowel distention was excellent and moderate in most volunteers and patients. CT features of many kinds of diseases such as tumors, Crohn's disease,and small bowel obstruction,etc. were clearly displayed.CONCLUSION: Multi-detector CT enterography with iso-osmotic mannitol as negative contrast to distend the small bowel is a simple, rapid, noninvasive and effective method of evaluating small bowel disease.

  18. Obscure gastrointestinal bleeding and small bowel pathology: comparison between wireless capsule endoscopy and multidetector-row CT enteroclysis.

    Science.gov (United States)

    Filippone, Antonella; Cianci, Roberta; Milano, Angelo; Valeriano, Sergio; Di Mizio, Veronica; Storto, Maria Luigia

    2008-01-01

    Obscure gastrointestinal bleeding is defined as bleeding of unknown origin, that persists or recurs after negative conventional barium contrast studies and upper and lower tract endoscopy. The causes of such a bleeding frequently arise in the small bowel, and they are represented by mucosal vascular abnormalities, neoplasms and other conditions such as Crohn's disease, Meckel's diverticulum, and vasculitis. Conventional barium contrast studies and push enteroscopy allow only a limited small bowel examination; moreover, intraoperative endoscopy may be inconclusive, since the small bowel is difficult to evaluate given its length and tortuous course. In the same way, angiographic diagnosis is stricktly related to the activity rate of hemorrhage. Wireless capsule endoscopy and multidetector-row CT enteroclysis are two recently developed minimally invasive techniques that may provide a complete small bowel examination, the first offering a direct visualization of the mucosal aspect, the second allowing evaluation of mural and extramural pathologies. This review is an update of the technique and clinical application of capsule endoscopy and multidetector-row CT enteroclysis in patients suffering from obscure small bowel bleeding.

  19. Multi-scale analysis of lung computed tomography images

    CERN Document Server

    Gori, I; Fantacci, M E; Preite Martinez, A; Retico, A; De Mitri, I; Donadio, S; Fulcheri, C

    2007-01-01

    A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

  20. Computed tomography of Crohn’s disease: The role of three dimensional technique

    OpenAIRE

    Raman, Siva P.; Horton, Karen M.; Fishman, Elliot K.

    2013-01-01

    Crohn’s disease, a transmural inflammatory bowel disease, remains a difficult entity to diagnose clinically. Over the last decade, multidetector computed tomography (CT) has become the method of choice for non-invasive evaluation of the small bowel, and has proved to be of significant value in the diagnosis of Crohn’s disease. Advancements in CT enterography protocol design, three dimensional (3-D) post-processing software, and CT scanner technology have allowed increasing accuracy in diagnos...

  1. Determination of the weighted CT dose index in modern multi-detector CT scanners.

    Science.gov (United States)

    Perisinakis, K; Damilakis, J; Tzedakis, A; Papadakis, A; Theocharopoulos, N; Gourtsoyiannis, N

    2007-11-07

    The aim of the present study was to (a) evaluate the underestimation in the value of the free-in-air (CTDI(air)) and the weighted CT dose index (CTDI(w)) determined with the standard 100 mm pencil chamber, i.e. the CTDI(100) concept, for the whole range of nominal radiation beam collimations selectable in a modern multi-slice CT scanner, (b) estimate the optimum length of the pencil-chamber and phantoms for accurate CTDI(w) measurements and (c) provide CTDI(w) values normalized to free-in-air CTDI for different tube-voltage, nominal radiation beam collimations and beam filtration values. The underestimation in the determination of CTDI(air) and CTDI(w) using the CTDI(100) concept was determined from measurements obtained with standard polymethyl-methacrylate (PMMA) phantoms and arrays of thermoluminescence dosimeters. The Monte Carlo N-Particle transport code was used to simulate standard CTDI measurements on a 16-slice CT scanner. The optimum pencil-chamber length for accurate determination of CTDI(w) was estimated as the minimum chamber length for which a further increase in length does not alter the value of the CTDI. CTDI(w)/CTDI(air) ratios were determined using Monte Carlo simulation and the optimum detector length for all selectable tube-voltage values and for three different values of beam filtration. To verify the Monte Carlo results, measured values of CTDI(w)/CTDI(air) ratios using the standard 100 mm pencil ionization chamber were compared with corresponding values calculated with Monte Carlo experiments. The underestimation in the determination of CTDI(air) using the 100 mm pencil chamber was less than 1% for all beam collimations. The underestimation in CTDI(w) was 15% and 27% for head and body phantoms, respectively. The optimum detector length for accurate CTDI(w) measurements was found to be 50 cm for the beam collimations commonly employed in modern multi-detector (MD) CT scanners. The ratio of CTDI(w)/CTDI(air) determined using the optimum

  2. Sex- and age-related differences of myocardial perfusion at rest assessed with multidetector computed tomography

    DEFF Research Database (Denmark)

    Byrne, Christina; Kühl, J Tobias; Zacho, Mette;

    2013-01-01

    The clinical presentation of ischemic heart disease in women differs from men, which could reflect sex-related differences of normal physiology. Cardiac CT angiography provides a noninvasive method to assess both regional and transmural myocardial perfusion in addition to coronary atherosclerosis....

  3. Measurements of pericardial adipose tissue using contrast enhanced cardiac multidetector computed tomography—comparison with cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Elming, Marie Bayer; Lønborg, Jacob; Rasmussen, Thomas;

    2013-01-01

    Recent studies have suggested that pericardial adipose tissue (PAT) located in close vicinity to the epicardial coronary arteries may play a role in the development of coronary artery disease. PAT has primarily been measured with cardiac magnetic resonance imaging (CMRI) or with non...... tested, and the smallest difference in PAT was noted when -30 to -190 HU were used in MDCT measures. The median difference between MDCT and CMRI for the assessment of PAT was 9 ml (SD 50) suggesting a reasonable robust method for the assessment of PAT in a large-scale study. Pericardial adipose tissue...... and CMRI scans were performed. The optimal fit for measuring PAT using contrast MDCT was developed and validated by the corresponding measures on CMRI. The median for PAT volume in patients was 175 ml (SD 68) and 153 ml (SD 60) measured by MDCT and CMRI respectively. Four different attenuation values were...

  4. Infections of the neck leading to descending necrotizing mediastinitis: Role of multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Antonio [Department of Diagnostic Imaging, A. Cardarelli Hospital, 80131 Naples (Italy)], E-mail: antopin1968@libero.it; Scaglione, Mariano; Scuderi, Maria Giuseppina; Tortora, Giovanni; Daniele, Stefania; Romano, Luigia [Department of Diagnostic Imaging, A. Cardarelli Hospital, 80131 Naples (Italy)

    2008-03-15

    Descending necrotizing mediastinitis is an acute, polymicrobial infection of the mediastinum, originating from odontogenic, oropharyngeal and cervical infections. Anatomical continuity of the fascial spaces between the neck and the mediastinum leads to an occasional mediastinal extension of deep neck infection as a serious sequela. An understanding of the anatomy of the deep spaces of the neck and familiarity with the imaging findings in descending necrotizing mediastinitis may allow rapid diagnosis and treatment of this rare and life-threatening complication of deep neck space infection. In this article, we discuss the current role of radiology in diagnosing descending necrotizing mediastinitis, in determining the level of infection and the pathways of spread of infections from the neck to the mediastinum and in planning a successful treatment.

  5. Long-term prognostic implication of coronary plaque characterization as detected by 64-multidetector computed tomography in Egyptian population

    Directory of Open Access Journals (Sweden)

    Mohammad A. Sadaka

    2017-03-01

    Conclusion: MDCT is a non-invasive imaging modality with a prognostic utility in patients with known or suspected coronary artery disease by applying plaque characterization and it could identify vulnerable plaques by measuring the total amount of NCP in non-obstructive lesions which could be useful for detecting patients at risk of acute coronary syndrome (ACS and guide further preventive therapeutic strategies. CACS was shown to be an independent predictor of mortality, while total amount of obstructive volume was shown to be an independent predictor of symptoms driven revascularization.

  6. Utility of multidetector row computed tomography and virtual bronchoscopy in evaluation of hemoptysis due to lung cancer

    Directory of Open Access Journals (Sweden)

    Sherif A.A. Mohamed

    2016-01-01

    Conclusion: MDCT angiography is a useful and non invasive method that allows a rapid and detailed identification of abnormal vasculature responsible for hemoptysis in patients with lung cancer. MDCT-generated virtual bronchoscopy is an accurate, and non invasive method for evaluating obstructions, endoluminal masses, and external compressions in patients with hemoptysis due to lung cancer.

  7. Ontogenetic study of the scapula among some Egyptians: Forensic implications in age and sex estimation using Multidetector Computed Tomography

    Directory of Open Access Journals (Sweden)

    Fatma M.M. Badr El Dine

    2016-06-01

    Conclusions: The results achieved from the current study are useful tools in the diagnosis of age and sex in both forensic and bio-archeological identification procedures; however, further studies are strongly suggested.

  8. In-vivo measurements of coronary blood flow using 16-slice multidetector spiral computed tomography (MDCT) in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Krug, Kathrin Barbara; Bovenschulte, H. [Klinikum der Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; Geissler, H.J. [Klinikum der Koeln Univ. (DE). Klinik und Poliklinik fuer Herz- und Thoraxchirurgie] (and others)

    2009-03-15

    To determine whether CTCA supplemented with CT flow measurements can be used to demonstrate and semiquantitatively evaluate poststenotic coronary blood flow in a porcine model. In 10 thoracotomized pigs, transit time flow meter probes were attached to the aorta and left anterior descending artery (LAD) for real-time blood flow volumetry. A vascular silicone occluder was deployed around the LAD proximal to the probe to create medium-grade (MGS) and high-grade stenoses (HGS). The blood flow was measured by CT without vessel occlusion and distal to the stenoses. Time-density curves were generated from CT data. The curves were evaluated by calculating and cross-plotting the variables ''slope of the density increase'', ''peak density'' and ''slope of the post-peak density decrease'' from the LAD and aortic CT data. The flow in the LAD dropped to 41 % {+-} 9 % (mean {+-} SD) for MGS and 12 % {+-} 6 % for HGS of the baseline. Coronary time-density curves plateaued proportional to luminal narrowing. Unimpaired flow could be differentiated statistically significant from poststenotic flow adjacent to MGS and HGS (p < 0.000 and p < 0.002, respectively). Flow adjacent to MGS and HGS was successfully differentiated for ''slope of the density increase'' and ''slope of the post-peak density decrease'' (p < 0.003 and p < 0.030, respectively). (orig.)

  9. Congenital left ventricular wall abnormalities in adults detected by gated cardiac multidetector computed tomography: Clefts, aneurysms, diverticula and terminology problems

    Energy Technology Data Exchange (ETDEWEB)

    Erol, Cengiz, E-mail: drcengizerol@yahoo.com [Selcuk University, Selcuklu Faculty of Medicine, Department of Radiology, Alaeddin Keykubat Central Campus, Selcuklu, 42250 Konya (Turkey); Koplay, Mustafa, E-mail: koplaymustafa@hotmail.com [Selcuk University, Selcuklu Faculty of Medicine, Department of Radiology, Alaeddin Keykubat Central Campus, Selcuklu, 42250 Konya (Turkey); Olcay, Ayhan, E-mail: drayhanolcay@gmail.com [29 May Hospital, Department of Cardiology, Vatan Street, Fatih, 34150 Istanbul (Turkey); Kivrak, Ali Sami, E-mail: alisamikivrak@hotmail.com [Selcuk University, Selcuklu Faculty of Medicine, Department of Radiology, Alaeddin Keykubat Central Campus, Selcuklu, 42250 Konya (Turkey); Ozbek, Seda, E-mail: dsadr@hotmail.com [Selcuk University, Selcuklu Faculty of Medicine, Department of Radiology, Alaeddin Keykubat Central Campus, Selcuklu, 42250 Konya (Turkey); Seker, Mehmet, E-mail: hikmet.irfan@hotmail.com [29 May Hospital, Department of Radiology, Vatan Street, Fatih, 34150 Istanbul (Turkey); Paksoy, Yahya, E-mail: yahyapaksoy@yahoo.com [Selcuk University, Selcuklu Faculty of Medicine, Department of Radiology, Alaeddin Keykubat Central Campus, Selcuklu, 42250 Konya (Turkey)

    2012-11-15

    Objectives: Our aim was to evaluate congenital left ventricular wall abnormalities (clefts, aneurysms and diverticula), describe and illustrate imaging features, discuss terminology problems and determine their prevalence detected by cardiac CT in a single center. Materials and methods: Coronary CT angiography images of 2093 adult patients were evaluated retrospectively in order to determine congenital left ventricular wall abnormalities. Results: The incidence of left ventricular clefts (LVC) was 6.7% (141 patients) and statistically significant difference was not detected between the sexes regarding LVC (P = 0.5). LVCs were single in 65.2% and multiple in 34.8% of patients. They were located at the basal to mid inferoseptal segment of the left ventricle in 55.4%, the basal to mid anteroseptal segment in 24.1%, basal to mid inferior segment in 17% and septal-apical septal segment in 3.5% of cases. The cleft length ranged from 5 to 22 mm (mean 10.5 mm) and they had a narrow connection with the left ventricle (mean 2.5 mm). They were contractile with the left ventricle and obliterated during systole. Congenital left ventricular septal aneurysm that was located just under the aortic valve was detected in two patients (0.1%). No case of congenital left ventricular diverticulum was detected. Conclusion: Cardiac CT allows us to recognize congenital left ventricular wall abnormalities which have been previously overlooked in adults. LVC is a congenital structural variant of the myocardium, is seen more frequently than previously reported and should be differentiated from aneurysm and diverticulum for possible catastrophic complications of the latter two.

  10. Transmural myocardial perfusion gradients in relation to coronary artery stenoses severity assessed by cardiac multidetector computed tomography

    DEFF Research Database (Denmark)

    Linde, Jesper James; Kühl, Jørgen Tobias; Hove, Jens Dahlgaard;

    2015-01-01

    = stress - PI/rest - PI), and the transmural perfusion ratio (TPR = subendocardium/subepicardium) were calculated. A coronary artery stenosis ≥50 % was present in 49 patients (25 %). Rest-PI and rest-TPR values were similar in patients with and without a coronary artery stenosis ≥50 %, whereas stress......-PI, stress-TPR and MPR were significantly reduced in patients with a stenosis ≥50 % (p ... during stress in patients with ≥50 % stenosis. In a broad spectrum of stenosis severity groups, TPR at rest remained unchanged until the group of patients with total occlusions, whereas TPR during stress decreased progressively when a threshold of 50 % was superseded. In this study we establish...

  11. Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ganten, Maria-Katharina [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany); Krautter, Ute; Tengg-Kobligk, Hendrik von; Delorme, Stefan; Kauczor, Hans-Ulrich [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Boeckler, Dittmar; Schumacher, Hardy [Ruprecht-Karls-University of Heidelberg, Department of Vascular and Endovascular Surgery, Heidelberg (Germany); Stiller, Wolfram; Bock, Michael [Deutsches Krebsforschungszentrum, Department of Medical Physics in Radiology, Medical Physics in Radiology, Heidelberg (Germany); Kauffmann, Guenter W. [Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany)

    2008-05-15

    To detect distensibility changes that might be an indicator for an increased risk of rupture, cross-sectional area changes of abdominal aortic aneurysms (AAA) have been determined using ECG-gated CT. Distensibility measurements of the aorta were performed in 67 patients with AAA. Time-resolved images were acquired with a four detector-row CT system using a modified CT-angiography protocol. Pulsatility-related cross-sectional area changes were calculated above and at AAA level by semiautomatic segmentation; distensibility values were obtained using additional systemic blood pressure measurements. Values were compared for small Oe< 5 cm (n=44) and large Oe> 5 cm (n = 23) aneurysms. The aorta could be segmented successfully in all patients. Upstream AAA distensibility D was significantly higher than at AAA level for both groups: means above AAA (at AAA) D{sub above} = (1.3 {+-}0.8) .10 {sup -5} Pa {sup -1} (D{sub AAA} = (0.6 {+-}0.5) .10 {sup -5} Pa {sup -1}) t-test p{sub D}<0.0001. Differences of the distensibility between smaller and larger aneurysms were not found to be significant. Distensibility can be measured non-invasively with ECG-gated CT. The reduction of distensibility within aneurysms compared to normal proximal aorta is subtle; the lack of difference between both small and large aneurysms suggests that this reduction occurs early in the aneurysm's development. Hence, reduced distensibility might be a predictive parameter in patients with high risk of aortic disease. (orig.)

  12. Diagnostic accuracy of triple-contrast multi-detector computed tomography for detection of penetrating gastrointestinal injury: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Saksobhavivat, Nitima [Faculty of Medicine Ramathibodi Hospital, Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ratchathewi, Bangkok (Thailand); Shanmuganathan, Kathirkamanathan; Boscak, Alexis R.; Sliker, Clint W.; Bodanapally, Uttam K.; Archer-Arroyo, Krystal; Miller, Lisa A.; Fleiter, Thorsten R.; Alexander, Melvin T.; Mirvis, Stuart E. [University of Maryland School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Baltimore, MD (United States); Stein, Deborah M.; Scalea, Thomas M. [University of Maryland School of Medicine, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States)

    2016-11-15

    Neither the performance of CT in diagnosing penetrating gastrointestinal injury nor its ability to discriminate patients requiring either observation or surgery has been determined. This was a prospective, single-institutional observational study of patients with penetrating injury to the torso who underwent CT. Based on CT signs, reviewers determined the presence of a gastrointestinal injury and the need for surgery or observation. The primary outcome measures were operative findings and clinical follow-up. CT results were compared with the primary outcome measures. Of one hundred and seventy-one patients (72 gunshot wounds, 99 stab wounds; age range, 18-57 years; median age, 28 years) with penetrating torso trauma who underwent CT, 45 % were followed by an operation and 55 % by clinical follow up. Thirty-five patients had a gastrointestinal injury at surgery. The sensitivity, specificity, and accuracy of CT for diagnosing a gastrointestinal injury for all patients were each 91 %, and for predicting the need for surgery, they were 94 %, 93 %, 93 %, respectively. Among the 3 % of patients who failed observation, 1 % had a gastrointestinal injury. CT is a useful technique to diagnose gastrointestinal injury following penetrating torso injury. CT can help discriminate patients requiring observation or surgery. (orig.)

  13. Interobserver agreement in fusion status assessment after instrumental desis of the lower lumbar spine using 64-slice multidetector computed tomography

    DEFF Research Database (Denmark)

    Laoutliev, Borislav; Havsteen, Inger; Bech, Birthe Højlund;

    2012-01-01

    Persistent lower back pain after instrumental posterolateral desis may arise from incomplete fusion. We investigate the impact of experience on interobserver agreement in fusion estimation.......Persistent lower back pain after instrumental posterolateral desis may arise from incomplete fusion. We investigate the impact of experience on interobserver agreement in fusion estimation....

  14. Eficacia de la angiotomografía multidetectores en el diagnóstico del trauma arterial de las extremidades

    Directory of Open Access Journals (Sweden)

    Martín Ochoa Escudero

    2008-11-01

    Full Text Available

    OBJETIVO: determinar la eficacia de la angiotomografia multidetectores en el diagnóstico del trauma arterial de las extremidades en los pacientes que ingresen al Hospital Universitario San Vicente de Paúl, de Medellín, Colombia, con sospecha de lesión arterial sin indicación de cirugía inmediata, comparada con los hallazgos quirúrgicos, la arteriografía y el seguimiento clínico; además, evaluar la variabilidad interobservador entre un radiólogo general y otro experto en trauma.

    MATERIALES Y MÉTODOS: durante 44 meses, entre agosto de 2004 y abril del 2008, se les hizo angiotomografía multidetectores a 99 extremidades con sospecha de lesión vascular traumática en 96 pacientes. Los estudios fueron interpretados por el radiólogo de turno y sus hallazgos se compararon con los de la cirugía, la arteriografía o el seguimiento (clínico o telefónico. Se evaluó además la variabilidad interobservador comparando la lectura de la angiotomografía hecha por el radiólogo de turno con la lectura retrospectiva de un radiólogo experto en trauma.

    RESULTADOS: la angiotomografía multidetectores, como método diagnóstico en el trauma vascular de las extremidades, demostró sensibilidad de 98% (IC 95%: 93-100, especificidad de 88% (IC 95%: 77-99, valor predictivo positivo de 91% (IC 95%: 82

  15. Prenatal diagnosis of chondrodysplasia punctata tibia-metacarpal type using multidetector CT and three-dimensional reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu [National Centre for Child Health and Development, Department of Radiology, Tokyo (Japan); Nishimura, Gen [Tokyo Metropolitan Kiyose Children' s Hospital, Department of Radiology, Tokyo (Japan); Sago, Haruhiko; Watanabe, Noriyoshi; Ebina, Shunsuke [National Centre for Child Health and Development, Department of Perinatal Medicine and Maternal Care, Tokyo (Japan)

    2007-11-15

    We report a case of chondrodysplasia punctata tibia-metacarpal type (CDP-TM) that was diagnosed prenatally using multidetector CT (MDCT) with three-dimensional (3-D) CT reconstructions. Prenatal US had shown severe thoracic hypoplasia and rhizomelic shortening of the limbs, raising the suspicion of thanatophoric dysplasia. However, MDCT showed punctate calcifications in the epiphyseal cartilage of the humeri and femora, carpal bones, and paravertebral region. On 3-D CT, the tibiae were much shorter than the fibulae, the humeri were very short and bowed, and severe platyspondyly was evident. These findings led to the diagnosis of CDP-TM. The diagnosis was confirmed on postnatal radiographs. Prenatal MDCT with 3-D images may make a useful contribution to prenatal diagnosis in selected fetuses with severe skeletal dysplasia. (orig.)

  16. Multidetector-Row CT Findings of a Preduodenal Portal Vein Associated with Polysplenic Syndrome in an Adult: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyun; Lee, Su Lim; Ku, Young Mi; Chun, Chang Woo [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, The Catholic University of Korea College of Medicine, Uijeongbu (Korea, Republic of)

    2012-03-15

    Preduodenal portal vein (PDPV) is a rare developmental anomaly in which the portal vein runs at the ventral side of the duodenum instead of at an intrapancreatic location. Understanding of this anomaly is of considerable surgical importance, because it may cause unintended portal vein injury during operations involving the gall bladder or duodenum. We recently experienced PDPV associated with polysplenia syndrome in a 49-year-old male patient who complained of persistent epigastric pain. CT portal venography with thin slab maximal intensity projection and volume rendering demonstrated the unique feature of convex anastomosis between the L-shaped mesenterico-portal vein and mesenterico-splenic vein in the mid abdomen. We report here the Multidetector-row CT findings of a rare case of PDPV.

  17. Angiographic frequency of blunt cerebrovascular injury in patients with carotid canal or vertebral foramen fractures on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    McKinney, Alexander [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)]. E-mail: mckin022@umn.edu; Ott, Frederick [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Short, James [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); McKinney, Zeke [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Truwit, Charles [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)

    2007-06-15

    Purpose: Blunt carotid injuries (BCI's) and blunt vertebral artery injuries (BVI's), known jointly as BCVI's, are common in 'high risk' patients. The purpose is to evaluate the rate of occurrence of BCI/BVI in patients screened purely by the radiologic criteria of fracture through the carotid canal or vertebral transverse foramina, or significant cervical subluxation, noted by multidetector CT. Methods: Seventy-one patients with 108 catheterized vessels were included over a 13-month interval. The angiographic examinations were prompted by current hospital protocol, solely by the presence of fractures involving/adjacent to the carotid canal, cervical fractures involving/adjacent to the foramen transversarium, or cervical fractures with significant subluxation. The incidence of each grade of blunt injury was calculated after review of the CT scans and catheter angiograms by two neuroradiologists. Results: Two thousand and seventy-three total blunt trauma admissions occurred during the time period, with a BCVI rate of 0.92-1.0% (depending on the reviewer), similar to previous studies. Mean time to catheter angiography was 16.6 h. Of the 71 included patients, there were 11-12 BCI's and 10-12 BVI's, an overall rate of 27-30% of BCVI in the patients with foraminal fractures. Interobserver agreement in reviewing the catheter angiograms was excellent (Kappa 0.795). Of note, three internal carotid pseudoaneurysms resolved spontaneously after anticoagulation or aspirin. Conclusion: This study confirms that there is a high rate of BCVI in the presence of carotid canal or vertebral foramen fractures that are noted by multidetector CT. Utilization of purely radiologic criteria of foraminal involvement may be a significant screening tool in the decision of whether to evaluate these patients acutely by catheter or CT angiography, and for early detection of patients at risk for symptomatology, to initiate prompt, prophylactic treatment.

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ... after the procedure? CT exams are generally painless, fast and easy. With multidetector CT, the amount of ...

  19. Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose.

    Science.gov (United States)

    DeMarco, J J; Cagnon, C H; Cody, D D; Stevens, D M; McCollough, C H; Zankl, M; Angel, E; McNitt-Gray, M F

    2007-05-07

    The purpose of this work is to examine the effects of patient size on radiation dose from CT scans. To perform these investigations, we used Monte Carlo simulation methods with detailed models of both patients and multidetector computed tomography (MDCT) scanners. A family of three-dimensional, voxelized patient models previously developed and validated by the GSF was implemented as input files using the Monte Carlo code MCNPX. These patient models represent a range of patient sizes and ages (8 weeks to 48 years) and have all radiosensitive organs previously identified and segmented, allowing the estimation of dose to any individual organ and calculation of patient effective dose. To estimate radiation dose, every voxel in each patient model was assigned both a specific organ index number and an elemental composition and mass density. Simulated CT scans of each voxelized patient model were performed using a previously developed MDCT source model that includes scanner specific spectra, including bowtie filter, scanner geometry and helical source path. The scan simulations in this work include a whole-body scan protocol and a thoracic CT scan protocol, each performed with fixed tube current. The whole-body scan simulation yielded a predictable decrease in effective dose as a function of increasing patient weight. Results from analysis of individual organs demonstrated similar trends, but with some individual variations. A comparison with a conventional dose estimation method using the ImPACT spreadsheet yielded an effective dose of 0.14 mSv mAs(-1) for the whole-body scan. This result is lower than the simulations on the voxelized model designated 'Irene' (0.15 mSv mAs(-1)) and higher than the models 'Donna' and 'Golem' (0.12 mSv mAs(-1)). For the thoracic scan protocol, the ImPACT spreadsheet estimates an effective dose of 0.037 mSv mAs(-1), which falls between the calculated values for Irene (0.042 mSv mAs(-1)) and Donna (0.031 mSv mAs(-1)) and is higher relative

  20. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  1. Advanced Gastric Cancer: Differentiation of Borrmann Type IV versus Borrmann Type III by Two-Phased Dynamic Multi-Detector Row CT with Use of the Water Filling Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Yu, Jeong Sik; Lee, Sang Min; Kim, Joo Hee; Chung, Jae Joon; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kang, Hae Youn [CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2013-02-15

    To characterize Borrmann type IV from Borrmann type III advanced gastric cancer (AGC) by two-phased multi-detector row computed tomography (MDCT) using the water filling method. A total of 143 patients (pathologically confirmed Borrmann type III and IV - 100 and 43 patients), who underwent preoperative MDCT, were enrolled. Two radiologists, retrospectively and independently, determined tumor enhancement pattern using a 5-grade scale without clinical information. A weighted kappa test was applied for interobserver variability. The score of tumor enhancement pattern correlated with Borrmann type as determined by Spearman's correlation coefficient. The accuracy of differentiation of Borrmann type using MDCT was determined by receiver operating characteristic curves. Interobserver agreement (weighted kappa = 0.683) was substantial. The tumor enhancement pattern score showed a significant correlation with Borrmann type (reviewer 1, r = 0.591, p < 0.001; reviewer 2, r = 0.616, p < 0.001). The accuracy for differentiation of Borrmann type on MDCT was 0.86 (p < 0.001) in both reviewers. The sensitivity and specificity of the diagnosis of Borrmann type IV were 79% and 82% in reviewer 1, and 88% and 78% in reviewer 2, respectively. Dual-phased MDCT using the water filling method can differentiate between Borrmann type IV and III AGC with high accuracy.

  2. Multidetector CT Assessment of Lymph Node Size for Nodal Staging in Patients with Potentially Operable Squamous Esophageal Cancer and the 18F-FDG Positron Emission Tomography CT Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Yoom, Soo Kyung; Jung, Jung Im; Ahn, Myeong Im; Park, Jae Gil; Yoo, Ie Ryung; Park, Seog Hee [Catholic University Seoul St. Mary' s Hospital, Seoul (Korea, Republic of); Park, Mi Jung [Gyeongsang National University Hospital, Junju (Korea, Republic of); Park, Hyun Jin [Catholic University St. Vincent Hospital, Suwon (Korea, Republic of)

    2010-03-15

    To investigate the size criteria of multidetector computed tomography (MDCT) for the evaluation metastatic lymph nodes (LNs) for potentially operable squamous esophageal cancer, and to compare this information with the results of positron emission tomography-CT (PET-CT). Twenty-four patients who underwent radical esophagectomy for esophageal cancer were studied. All patients had preoperative MDCT and PET-CT. The MDCT findings were compared with those of PET-CT and were correlated with the surgical records. The receiver operating characteristic (ROC) curve method was used to determine the appropriate cut-off value to distinguish benign from metastatic LNs. The size of metastatic LNs (9.35 {+-} 3.41 mm) was significantly larger than that of benign LNs (5.74 {+-} 1.64 mm) (p<0.001). The best cut-off value was 7 mm (81.8% sensitivity, 80.8% specificity). PET-CT detected all metastatic LNs except for four in the peritumoral region. The sensitivity and specificity of metastatic LN evaluation on PET-CT were 82.6% and 99.4%, respectively. Only one LN without metastasis showed increased fluoro-2-deoxy-D-glucose uptake on PET-CT. Size of metastatic LNs can typically be < 10 mm. For MDCT, the short diameter of 7 mm may be the optimal criterion. PET-CT is very accurate for the assessment of metastatic LNs except for those in the peritumoral region.

  3. Morphometric evaluation of subaxial cervical spine using multi-detector computerized tomography (MD-CT) scan: the consideration for cervical pedicle screws fixation

    OpenAIRE

    Chanplakorn, Pongsthorn; Kraiwattanapong, Chaiwat; Aroonjarattham, Kitti; Leelapattana, Pittavat; Keorochana, Gun; Jaovisidha, Suphaneewan; Wajanavisit, Wiwat

    2014-01-01

    Background Cervical pedicle screw (CPS) insertion is a technically demanding procedure. The quantitative understanding of cervical pedicle morphology, especially the narrowest part of cervical pedicle or isthmus, would minimize the risk of catastrophic damage to surrounding neurovascular structures and improve surgical outcome. The aim of this study was to investigate morphology and quantify cortical thickness of the cervical isthmus by using Multi-detector Computerized Tomography (MD-CT) sca...

  4. Gamma multi-detectors and nuclear structure studies: search for superdeformed structures in {sup 147}Gd and {sup 144}Gd isotopes using Crystal Castle; simulation calculations for EUROGAM multi-detector definition; Multidetecteurs gamma et etudes de structure nucleaire: recherche avec le Chateau de Cristal de structures superdeformees dans les isotopes {sup 147}Gd et {sup 144}Gd; calculs de simulation pour la definition du multidetecteur EUROGAM

    Energy Technology Data Exchange (ETDEWEB)

    France, G. de

    1991-12-31

    Computer simulations have been used for the calculation of the new generation of 4 {pi}{gamma} multi-detectors (Castle Crystal) of EUROGAM system (phase I and II). Two superdeformed bands (I and II), comprising 16 and 13 transitions respectively, have been described for {sup 147}Gd nucleus during the {sup 122}Sn({sup 30}Si,5n) fusion-evaporation reaction in a 155 MeV bombardment energy. Dynamic inertia momentum similarities and gamma transition energy similarities have been observed between band I and {sup 148}Gd nucleus and between band II and {sup 146}Gd nucleus, respectively. These similarities can be related to a pseudo-spin symmetry. Calculations suggest the existence of an octupolar susceptibility in this mass region. {sup 144}Gd nucleus has been studied using {sup 120}Sn({sup 29}Si,5n) fusion-evaporation reaction in a 155 MeV bombardment energy and using {sup 100}Mo({sup 48}Ti,4n) reactions in a 200 MeV bombardment energy. {gamma}-{gamma} coincidences have revealed the existence of a 58 keV width valley in the matrix representation compatible with theoretical predictions. In spite of the evidence for about ten transitions during these experiments, no superdeformed structure has been demonstrated for {sup 144}Gd nucleus. (J.S.). 87 refs., 57 figs., 41 tabs.

  5. Computed tomography assessment of early response to neoadjuvant therapy in colon cancer

    DEFF Research Database (Denmark)

    Dam, Claus; Lund-Rasmussen, Vera; Pløen, John;

    2015-01-01

    INTRODUCTION: Using multidetector computed tomography, we aimed to assess the early response of neoadjuvant drug therapy for locally advanced colon cancer. METHODS: Computed tomography with IV contrast was acquired from 67 patients before and after up to three cycles of preoperative treatment. All...... patients had histologically confirmed colon cancer, a T4 or T3 tumour with extramural invasion ≥ 5 mm and no distant metastases or peritoneal nodules. The patients were treated with oxaliplatin and capecitabine. In addition, those with no mutations in the KRAS, BRAF and PIK3CA genes were also treated...

  6. Three dimensional endo-cardiovascular volume-rendered cine computed tomography of isolated left ventricular apical hypoplasia; A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sun Hwa; Kim, Yang Min; Lee, Hyun Jong [Sejong General Hospital, Bucheon (Korea, Republic of)

    2016-02-15

    We report multidetector computed tomography (MDCT) and cardiac magnetic resonance (CMR) findings of a 34-year-old female with isolated left ventricular apical hypoplasia. The MDCT and CMR scans displayed a spherical left ventricle (LV) with extensive fatty infiltration within the myocardium at the apex, interventricular septum and inferior wall, anteroapical origin of the papillary muscle, right ventricle wrapping around the deficient LV apex, and impaired systolic function. MDCT visualized morphologic and also functional findings of this unique cardiomyopathy.

  7. Multidetector CT Enterography versus Double-Balloon Enteroscopy: Comparison of the Diagnostic Value for Patients with Suspected Small Bowel Diseases

    Directory of Open Access Journals (Sweden)

    Jingjing Wang

    2016-01-01

    Full Text Available Aim. To compare the diagnostic value of multidetector CT enterography (MDCTE and double-balloon enteroscopy (DBE for patients with suspected small bowel diseases. Methods. From January 2009 to January 2014, 190 patients with suspected small bowel diseases were examined with MDCTE and DBE. The characteristics of the patients, detection rates, diagnostic yields, sensitivity, specificity, positive predictive value, and negative predictive value were described and analyzed. Results. The overall detection rates of DBE and MDCTE were 92.6% and 55.8%, respectively (P<0.05, while the overall diagnostic yields were 83.2% and 33.7%, respectively (P<0.05. The sensitivity, specificity, positive predictive value, and negative predictive value of DBE were all higher than those of MDCTE. DBE had a higher diagnostic yield for OGIB (87.3% versus 20.9%, P<0.05. The diagnostic yields of DBE were higher than those of MDCTE for inflammatory diseases, angioma/angiodysplasia, and diverticulums, while being not for gastrointestinal tumors/polyps. Conclusions. The diagnostic value of DBE for small bowel diseases is better than that of MDCTE as a whole, but if gastrointestinal tumors are suspected, MDCTE is also needed to gain a comprehensive and accurate diagnosis.

  8. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  9. Unenhanced multidetector CT (CT KUB) in the initial imaging of suspected acute renal colic: evaluating a new service

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, F.U. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom); Kotwal, S. [Urology, Leeds Teaching Hospitals, Leeds (United Kingdom); Raghunathan, G.; Wah, T.M. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom); Joyce, A. [Urology, Leeds Teaching Hospitals, Leeds (United Kingdom); Irving, H.C. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom)], E-mail: henry.irving@leedsth.nhs.uk

    2007-10-15

    Aim: To evaluate a new imaging pathway for the investigation of patients presenting with suspected acute renal colic. Materials and methods: A retrospective review of 500 consecutive cases of suspected acute renal colic was undertaken to evaluate the initial results of a new imaging pathway introduced at our institution, which completely replaced the intravenous urogram (IVU) with unenhanced multidetector CT (CT KUB). Results: The positive rate for urolithiasis was 44% (221/500), the negative rate 46% (229/500) and the rate of other significant findings was 12% (59/500). Female patients had a low positive rate compared with male patients (27.5 versus 57.5%; p < 0.001). Urological intervention was required in 28% (61/221) and these patients had a larger average stone size (6.6 versus 3.7 mm; p < 0.001) and the stone was located more proximally. Out-of-hours imaging was performed in 37% (186/500), and these patients had a higher positive rate (52 versus 40%; p < 0.001). Other findings included a wide range of acute non-urological conditions. Conclusion: The feasibility of replacing the acute IVU with CT KUB in the initial assessment of suspected acute renal colic was demonstrated in the present study. The technique enables rapid diagnosis of urolithiasis, stratification of patients likely to proceed to urological intervention, and prompt diagnosis of a variety of other acute pathological conditions.

  10. Preoperative multidetector CT manifestations of perigastric lymph nodes in patients with early gastric cancer and pN0

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jung Hyun; Yu, Jeong Sik; Chung, Jae Joon; Lim, Joo Hee; Cho, Eun Suk; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2013-11-15

    To find the determinant of lymph node (LN) manifestations on preoperative multidetector CT (MDCT) in early gastric cancer (EGC) patients with pN0. One hundred and eighty-six consecutive patients with pT1pN0, the largest perigastric LN on preoperative MDCT, were categorized into two groups according to 8 different parameters [short (SD) and long diameter (LD) 4/6/8 mm, average attenuation 100 Hounsfield unit, short-to-long diameter-ratio (SLR) 0.7], and correlated with the size, gross type, depth of invasion and microscopic type of their primary lesions by the chi-square test and multiple logistic regression analysis. When the primary lesion was larger than 3 cm, the LNs were larger in 4 parameters (SD or LD, 4/6 mm; p < 0.05); gross type IIb patients showed smaller LNs in 5 parameters (SD 4/6 mm, LD 4/6/8 mm; p < 0.05); and patients with microscopically-undifferentiated lesions showed larger LNs in SD 4 mm or LD 8 mm by the chi-square test and multiple logistic regression analysis. The depth of invasion showed no significant difference in LN size. No factors revealed significant difference in LN attenuation or SLR. Benign regional LN enlargement is more frequent in EGC patients with larger size primary lesions or lesion with poor microscopic differentiation. However, this condition is less frequent in gross type IIb patients.

  11. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

    Science.gov (United States)

    Sauerbier, Sebastian; Duttenhoefer, Fabian; Sachlos, Elefterios; Haberstroh, Jörg; Scheifele, Christian; Wrbas, Karl-Thomas; Voss, Pit Jacob; Veigel, Egle; Smedek, Jörg; Ganter, Philip; Tuna, Taskin; Gutwald, Ralf; Palmowski, Moritz

    2013-10-01

    Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

  12. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing [Huadong Hospital Fudan University, Department of Radiology, Shanghai (China); Zheng, Xiangpeng [Huadong Hospital Fudan University, Department of Radiation Oncology, Shanghai (China); Chen, Yan [Huadong Hospital Fudan University, Department of Pathology, Shanghai (China); Lv, Fangzhen [Huadong Hospital Fudan University, Department of Thoracic Surgery, Shanghai (China)

    2013-12-15

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  13. Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients

    Energy Technology Data Exchange (ETDEWEB)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J. [UMC Utrecht, Department of Radiology, P.O. Box 85500, E01.132, GA, Utrecht (Netherlands); Symersky, Petr [Onze Lieve Vrouwe Gasthuis, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Academic Medical Center Amsterdam, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Herwerden, Lex A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Mol, Bas A.J.M. de [Academic Medical Center Amsterdam, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Spijkerboer, Anje M. [Academic Medical Center Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2011-07-15

    Multidetector CT (MDCT) has shown potential for prosthetic heart valve (PHV) assessment. We assessed the image quality of different PHV types to determine which valves are suitable for MDCT evaluation. All ECG-gated CTs performed in our institutions since 2003 were reviewed for the presence of PHVs. After reconstruction in 3 specific PHV planes, image quality of the supravalvular, perivalvular, subvalvular and valvular regions was scored on a four-point scale (1 = non-diagnostic, 2 = moderate, 3 = good and 4 = excellent) by two independent observers. Eighty-four CT examinations (66 cardiac, 18 limited-dose aortic protocols) of 83 patients with a total of 91 PHVs in the aortic (n = 71), mitral (n = 17), pulmonary (n = 1) and tricuspid (n = 2) position were included. CT was performed on a 16-slice (n = 4), 64-slice (n = 28) or 256-slice (n = 52) MDCT system. Median image quality scores for the supra-, peri- and subvalvular regions and valvular detail were (3.5, 3.3, 3.5 and 3.5, respectively) for bileaflet PHV; (3.0, 3.0, 3.5 and 3.0, respectively) for Medtronic Hall PHV; (1.0, 1.0, 1.0 and 1.0, respectively) for Bjoerk-Shiley and Sorin monoleaflet PHV and (3.5, 3.5, 4.0 and 2.0 respectively) for biological PHV. Currently implanted PHVs have good image quality on MDCT and are suitable for MDCT evaluation. (orig.)

  14. Multidetector CT of pancreatic ductal adenocarcinoma: Effect of tube voltage and iodine load on tumour conspicuity and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Loizou, L.; Leidner, B.; Axelsson, E.; Fischer, M.A.; Grigoriadis, A.; Kartalis, N. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); C1-46 Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden); Albiin, N. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Ersta Hospital, Department of Radiology, Stockholm (Sweden); Del Chiaro, M.; Segersvaerd, R. [Karolinska University Hospital Huddinge, Division of Surgery, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet and Center for Digestive Diseases, Stockholm (Sweden); Verbeke, C. [Karolinska Institutet and Karolinska University Hospital Huddinge, Division of Pathology, Department of Laboratory Medicine, Stockholm (Sweden); Sundin, A. [Uppsala University Hospital, Department of Surgical Sciences, Division of Radiology, Uppsala University and Department of Radiology, Uppsala (Sweden)

    2016-11-15

    To compare a low-tube-voltage with or without high-iodine-load multidetector CT (MDCT) protocol with a normal-tube-voltage, normal-iodine-load (standard) protocol in patients with pancreatic ductal adenocarcinoma (PDAC) with respect to tumour conspicuity and image quality. Thirty consecutive patients (mean age: 66 years, men/women: 14/16) preoperatively underwent triple-phase 64-channel MDCT examinations twice according to: (i) 120-kV standard protocol (PS; 0.75 g iodine (I)/kg body weight, n = 30) and (ii) 80-kV protocol A (PA; 0.75 g I/kg, n = 14) or protocol B (PB; 1 g I/kg, n = 16). Two independent readers evaluated tumour delineation and image quality blindly for all protocols. A third reader estimated the pancreas-to-tumour contrast-to-noise ratio (CNR). Statistical analysis was performed with the Chi-square test. Tumour delineation was significantly better in PB and PA compared with PS (P = 0.02). The evaluation of image quality was similar for the three protocols (all, P > 0.05). The highest CNR was observed with PB and was significantly better compared to PA (P = 0.02) and PS (P = 0.0002). In patients with PDAC, a low-tube-voltage, high-iodine-load protocol improves tumour delineation and CNR leading to higher tumour conspicuity compared to standard protocol MDCT. (orig.)

  15. Differentiation of early gastric cancer with ulceration and resectable advanced gastric cancer using multiphasic dynamic multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Tsurumaru, Daisuke; Miyasaka, Mitsutoshi; Nishimuta, Yusuke; Asayama, Yoshiki; Nishie, Akihiro; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Kawanami, Satoshi [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Oki, Eiji [Kyushu University, Department of Surgery and Sciences, Graduate School of Medical Sciences, Fukuoka (Japan); Hirahashi, Minako [Kyushu University, Department of Anatomic Pathology and Pathological Sciences, Graduate School of Medical Sciences, Fukuoka (Japan)

    2016-05-15

    Early gastric cancer with ulceration (EGC-U) mimics advanced gastric cancer (AGC), as EGC-Us and ACGs often have similar endoscopic appearance to ulceration. The purpose of this retrospective study was to determine whether multiphasic dynamic multidetector CT (MDCT) can help differentiate EGC-Us from AGCs. Patients with EGC-Us with ulcer stages Ul-III or IV and AGCs with tumour stages T2 to T4a were enrolled. MDCT images were obtained 40 s (arterial phase), 70 s (portal phase) and 240 s (delayed phase) after injection of non-ionic contrast material. Two readers independently measured the attenuation values of the lesions by placing regions of interest. We compared the EGC-Us and AGCs using the mean attenuation values in each phase and peak enhancement phase. We analysed the diagnostic performance of CT for differentiating EGC-Us from AGCs. Forty cases (16 EGC-Us and 24 AGCs) were analysed. The mean attenuation values of the EGC-Us were significantly lower than those of the AGCs in both the arterial and portal phases (all p < 0.0001 for each reader). The peak enhancement was significantly different between the EGC-Us and AGCs for both readers (Reader 1, p = 0.0131; Reader 2, p = 0.0006). Multiphasic dynamic contrast-enhanced MDCT can help differentiate EGC-Us from AGCs. (orig.)

  16. Multi-Detector row CT urography on a 16-row CT scanner in the evaluation of urothelial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, A.C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); University of Ioannina, Medical School, Ioannina (Greece); Efremidis, S.C.; Tsampoulas, C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); Kalef-Ezra, J. [University Hospital of Ioannina, Department of Medical Physics, Ioannina (Greece); Giannakis, D.; Sofikitis, N. [University Hospital of Ioannina, Department of Urology, Ioannina (Greece); Alamanos, Y. [University Hospital of Ioannina, Department of Hygiene and Public Health, Ioannina (Greece)

    2007-04-15

    The purpose of this study was to assess the role of multi-detector row CT urography (MDCTU), on a 16-row CT scanner in the evaluation of patients with painless hematuria, with emphasis placed in the detection of urothelial tumors. We retrospectively reviewed the MDCT urographies of 75 patients, referred for painless hematuria. The CT protocol included unenhanced images, obtained with a detector configuration of 16 x 1.5 mm and pitch of 1.2, nephrographic and excretory-phase images, obtained with a detector collimation of 16 x 0.75 mm and pitch of 1.2. Axial and coronal reformatted images were evaluated. Three-dimensional reformation of the excretory-phase images was performed using the volume-rendering technique. The standard of reference included clinical and imaging follow-up, cystoscopic, surgical and histologic findings. In 55 (73%) of 75 patients, the cause of hematuria was identified on MDCTU; the most common cause was urothelial cancer, including seven tumors with a diameter equal or smaller than 0.5 cm in diameter. Sixteen-row MDCTU provided satisfactory results in the investigation of patients with painless hematuria. The main advantage of the technique is its ability to detect uroepithelial malignancies. (orig.)

  17. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT.

    Science.gov (United States)

    Jaeckle, T; Stuber, G; Hoffmann, M H K; Jeltsch, M; Schmitz, B L; Aschoff, A J

    2008-07-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT.

  18. Multi-detector CT and 3D imaging in a multi-vendor PACS environment

    NARCIS (Netherlands)

    van Ooijen, PMA; Witkamp, R; Oudkerk, M; Lemke, HU; Inamura, K; Doi, K; Vannier, MW; Farman, AG; Reiber, JHC

    2003-01-01

    Introduction of new hard- and software techniques like Multi-Dectector Computed Tomography (MDCT) and 3D imaging has put new demands on the Picture Archiving and Communications System (PACS) environment within the radiology department. The daily use of these new techniques requires a good integratio

  19. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    on the market today based on different perfusion algorithms. However, there is no consensus on which protocol and algorithm to use for specific organs. In this article, the authors give an introduction to CT perfusion in abdominal imaging introducing technical aspects for calculation of perfusion parameters......Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...

  20. Crossed Fused Renal Ectopia: Presentations on 99mTc-MAG3 Scan, 99mTc-DMSA SPECT, and Multidetector CT.

    Science.gov (United States)

    Moon, Eun Ha; Kim, Min-Woo; Kim, Young Jun; Sun, In O

    2015-10-01

    Crossed renal ectopia is an uncommon developmental anomaly in which both kidneys are located on the same side of the body. The present case describes a 20-year-old man who underwent the military entrance physical examination. The ultrasound showed the right kidney in normal site with slightly increased size, but the left kidney was not identified. Tc-MAG3 scan showed a single kidney with 2 ureters, and the orifices of the ureters were connected at both sides of bladder. Tc-DMSA SPECT and contrast-enhanced multidetector CT were performed and revealed crossed fused renal ectopia.

  1. Lung cancer perfusion at multi-detector row CT: reproducibility of whole tumor quantitative measurements.

    Science.gov (United States)

    Ng, Quan-Sing; Goh, Vicky; Fichte, Heinz; Klotz, Ernst; Fernie, Pat; Saunders, Michele I; Hoskin, Peter J; Padhani, Anwar R

    2006-05-01

    Institutional review board approval and informed consent were obtained for this study. The aim of the study was to prospectively assess, in patients with lung cancer, the reproducibility of a quantitative whole tumor perfusion computed tomographic (CT) technique. Paired CT studies were performed in 10 patients (eight men, two women; mean age, 66 years) with lung cancer. Whole tumor permeability and blood volume were measured, and reproducibility was evaluated by using Bland-Altman statistics. Coefficient of variation of 9.49% for permeability and 26.31% for blood volume and inter- and intraobserver variability ranging between 3.30% and 6.34% indicate reliable assessment with this whole tumor technique.

  2. Planimetric Measurement of the Regurgitant Orifice Area Using Multidetector CT for Aortic Regurgitation: a Comparison with the Use of Echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Min Hee; Choe, Yeon Hyeon; Cho, Soo Jin; Park, Seung Woo; Park, Pyo Won; Oh, Jae K. [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2010-04-15

    This study compared the area of the regurgitant orifice, as measured by the use of multidetector-row CT (MDCT), with the severity of aortic regurgitation (AR) as determined by the use of echocardiography for AR. In this study, 45 AR patients underwent electrocardiography- gated 40-slice or 64-slice MDCT and transthoracic or transesophageal echocardiography. We reconstructed CT data sets during mid-systolic to enddiastolic phases in 10% steps (20% and 35-95% of the R-R interval), planimetrically measuring the abnormally opened aortic valve area during diastole on CT reformatted images and comparing the area of the aortic regurgitant orifice (ARO) so measured with the severity of AR, as determined by echocardiography. In the 14 patients found to have mild AR, the ARO area was 0.18{+-} 0.13 cm{sup 2} (range, 0.04-0.54 cm{sup 2}). In the 15 moderate AR patients, the ARO area was 0.36 {+-} 0.23 cm{sup 2} (range, 0.09-0.81 cm{sup 2}). In the 16 severe AR patients, the ARO area was 1.00 {+-} 0.51 cm{sup 2} (range, 0.23-1.84 cm{sup 2}). Receiver-operator characteristic curve analysis determined a sensitivity of 85% and a specificity of 82%, for a cutoff of 0.47 cm{sup 2}, to distinguish severe AR from less than severe AR with the use of CT (area under the curve = 0.91; 95% confidence interval, 0.84-1.00; p < 0.001). Planimetric measurement of the ARO area using MDCT is useful for the quantitative evaluation of the severity of aortic regurgitation.

  3. Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, Damien; Remy-Jardin, Martine; Rozel, Celine; Remy, Jacques [University Center of Lille, Boulevard Jules Leclerc, Department of Thoracic Imaging, Hospital Calmette, Lille cedex (France); Dusson, Catherine; Wurtz, Alain [University Center of Lille, Department of Thoracic Surgery, Hospital Calmette, Lille cedex (France); Delannoy-Deken, Valerie; Duhamel, Alain [University of Lille, Department of Medical