WorldWideScience

Sample records for 510k radtag x-ray

  1. Premarket Notifications (510(k)s)

    Data.gov (United States)

    U.S. Department of Health & Human Services — Medical device manufacturers are required to submit a premarket notification or 510(k) if they intend to introduce a device into commercial distribution for the...

  2. X-Rays

    Science.gov (United States)

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  3. Chest x-ray

    Science.gov (United States)

    Chest radiography; Serial chest x-ray; X-ray - chest ... You stand in front of the x-ray machine. You will be told to hold your breath when the x-ray is taken. Two images are usually taken. You will ...

  4. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...

  5. X-ray (image)

    Science.gov (United States)

    X-rays are a form of ionizing radiation that can penetrate the body to form an image on ... will be shades of gray depending on density. X-rays can provide information about obstructions, tumors, and other ...

  6. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film ... dentist's office. There are many types of dental x-rays. Some are: Bitewing Periapical Palatal (also called occlusal) ...

  7. X-ray apparatus

    International Nuclear Information System (INIS)

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  8. Dental x-rays

    Science.gov (United States)

    X-ray - teeth; Radiograph - dental; Bitewings; Periapical film; Panoramic film; Digital image ... dentist's office. There are many types of dental x-rays. Some of them are: Bitewing. Shows the crown ...

  9. X-Rays

    Science.gov (United States)

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of your ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat and ...

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... by: Image/Video Gallery Your radiologist explains chest x-ray. Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  11. X-Ray Imaging

    Science.gov (United States)

    ... Brain Surgery Imaging Clinical Trials Basics Patient Information X-Ray Imaging Print This Page X-ray imaging is perhaps the most familiar type of imaging. Images produced by X-rays are due to the different absorption rates of ...

  12. 78 FR 26786 - 510(k) Device Modifications: Deciding When To Submit a 510(k) for a Change to an Existing Device...

    Science.gov (United States)

    2013-05-08

    ... management in the decision process on whether a medical device modification requires a new 510(k) submission... management into this decision process in a way that ensures appropriate and consistent modification decisions... and resolve the following concerns. 1. Risk Management is a Process--Published risk...

  13. X-Ray Polarimetry

    CERN Document Server

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.

  14. X-Ray Polarimetry

    OpenAIRE

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band ...

  15. X-ray - skeleton

    Science.gov (United States)

    A skeletal x-ray is an imaging test used to look at the bones. It is used to detect fractures , tumors, or ... in the health care provider's office by an x-ray technologist. You will lie on a table or ...

  16. Extremity x-ray

    Science.gov (United States)

    An extremity x-ray is an image of the hands, wrist, feet, ankle, leg, thigh, forearm humerus or upper arm, hip, shoulder ... term "extremity" often refers to a human limb. X-rays are a form of radiation that passes through ...

  17. X-ray interferometers

    International Nuclear Information System (INIS)

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  18. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  1. Lumbosacral spine x-ray

    Science.gov (United States)

    X-ray - lumbosacral spine; X-ray - lower spine ... The test is done in a hospital x-ray department or your health care provider's office by an x-ray technician. You will be asked to lie on the x-ray table ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  3. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  4. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  5. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  6. Medical X-Rays

    Science.gov (United States)

    ... The Conference of Radiation Control Program Directors (CRCPD) publishes Suggested State Regulations for the Control of Radiation , ... eSubmitter Guidance for Industry and Food and Drug Administration Staff - Assembler's Guide to Diagnostic X-Ray Equipment ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  10. 75 FR 4402 - Strengthening the Center for Devices and Radiological Health's 510(k) Review Process; Public...

    Science.gov (United States)

    2010-01-27

    ... requirement), that the device meets the comparative standard of ``substantial equivalence'' to a ``predicate... about devices that have been cleared for marketing through the 510(k) process. Currently, if a device... different ``intended uses'' and explain your reasoning. b. What are the advantages and disadvantages...

  11. Specific heat of rhenium disulfide in 360-510 K temperature range

    International Nuclear Information System (INIS)

    Isobaric specific heat of rhenium disulfide was measured by the method of differential scanning calorimetry in the range of 360-510 K. Thermodynamic functions of rhenium disulfide were calculated using literature data on standard entropy of the compound for the range of 296.15-600 K. 3 refs., 1 fig., 2 tabs

  12. 75 FR 47307 - Center for Devices and Radiological Health 510(k) Working Group Preliminary Report and...

    Science.gov (United States)

    2010-08-05

    ... HUMAN SERVICES Food and Drug Administration Center for Devices and Radiological Health 510(k) Working... ``Center for Devices and Radiological Health Preliminary Internal Evaluations,'' which is comprised of the... public input on the recommendations discussed in these reports, including the feasibility...

  13. X-ray Pulsars

    CERN Document Server

    Walter, Roland

    2016-01-01

    X-ray pulsars shine thanks to the conversion of the gravitational energy of accreted material to X-ray radiation. The accretion rate is modulated by geometrical and hydrodynamical effects in the stellar wind of the pulsar companions and/or by instabilities in accretion discs. Wind driven flows are highly unstable close to neutron stars and responsible for X-ray variability by factors $10^3$ on time scale of hours. Disk driven flows feature slower state transitions and quasi periodic oscillations related to orbital motion and precession or resonance. On shorter time scales, and closer to the surface of the neutron star, X-ray variability is dominated by the interactions of the accreting flow with the spinning magnetosphere. When the pulsar magnetic field is large, the flow is confined in a relatively narrow accretion column, whose geometrical properties drive the observed X-ray emission. In low magnetized systems, an increasing accretion rate allows the ignition of powerful explosive thermonuclear burning at t...

  14. X-ray astronomy

    International Nuclear Information System (INIS)

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  15. CRL X-RAY TUBE

    OpenAIRE

    Kolchevsky, N. N.; Petrov, P. V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed.

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... this Site RadiologyInfo.org is produced by: Image/Video Gallery Your radiologist explains chest x-ray. Transcript ... time! Spotlight Recently posted: Pediatric MRI Intravascular Ultrasound Video: Chest CT Video:Thyroid Ultrasound Video: Head CT ...

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... Pediatric Ultrasound Video: Angioplasty & vascular stenting Video: Arthrography Radiology and You About this Site RadiologyInfo.org is ... radiologist explains chest x-ray. Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... this Site RadiologyInfo.org is produced by: Image/Video Gallery Your radiologist explains chest x-ray. Transcript ... Recently posted: Focused Ultrasound for Uterine Fibroids Dementia Video: General Ultrasound Video: Pediatric Nuclear Medicine Radiology and ...

  19. Medical x-ray

    International Nuclear Information System (INIS)

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  20. Pyroelectric x-ray detectors and x-ray pyrometers

    International Nuclear Information System (INIS)

    This paper discusses pyroelectric detectors which are very promising x-ray detectors for intense pulsed x-ray/γ-ray measurements and can be used as x-ray pyrometers. They are fast, passive, and inherently flat in spectral response for low energy x-rays. The authors report tests of LiTaO3, Sr.5Ba.5Nb2O6 and LiNbO3 detectors at Nova laser with 1 ns low energy x-rays and at Zapp Z-pinch machine with 100 ns x-rays. The temporal and spectral responses are discussed

  1. Pyroelectric x-ray detectors and x-ray pyrometers

    International Nuclear Information System (INIS)

    Pyroelectric detectors are very promising x-ray detectors for intense pulsed x-ray/γ-ray measurements and can be used as x-ray pyrometers. They are fast, passive, and inherently flat in spectral response for low-energy x rays. We report our tests of LiTaO3 detectors at Nova laser with 1-ns low-energy x rays and at Zapp Z-pinch machine with 100-ns x rays. The temporal and spectral responses are discussed

  2. Fixing a 510(K) Loophole: In Support of The Sound Devices Act of 2012

    OpenAIRE

    Ho, Shuenn (Patrick)

    2014-01-01

    The current medical device regulatory system contains a dangerous loophole. While the voluntary recall of a harmful medical device removes it from the market, new devices that claim they are substantially equivalent to the recalled device can still reach the market through the 510(k) premarket notification process. Devices that have gained regulatory clearance in this fashion have caused considerable harm and are much more likely to be recalled for safety reasons as well. The recently propo...

  3. X-ray diffraction

    International Nuclear Information System (INIS)

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... images for evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... and Media Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to X-ray ( ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ...

  8. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si02. The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... As a result, bones appear white on the x-ray, soft tissue shows up in shades of gray and air appears black. Until recently, x-ray images were maintained on large film sheets (much ...

  11. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ...

  12. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The x-ray tube is connected to a flexible arm that is extended over the patient while an x-ray film holder or image recording plate is placed beneath the patient. top of page How does the procedure work? X-rays are a form of radiation like ...

  15. Tunable X-ray source

    Science.gov (United States)

    Boyce, James R.

    2011-02-08

    A method for the production of X-ray bunches tunable in both time and energy level by generating multiple photon, X-ray, beams through the use of Thomson scattering. The method of the present invention simultaneously produces two X-ray pulses that are tunable in energy and/or time.

  16. X-ray selected BALQSOs

    CERN Document Server

    Page, M J; Ceballos, M; Corral, A; Ebrero, J; Esquej, P; Krumpe, M; Mateos, S; Rosen, S; Schwope, A; Streblyanska, A; Symeonidis, M; Tedds, J A; Watson, M G

    2016-01-01

    We study a sample of six X-ray selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM-Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index alpha=0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, alpha_OX, of the X-ray selected BALQSOs, have a mean value of 1.69 +- 0.05, which is similar to that found for X-ray selected and optically selected non-BAL QSOs of similar ultraviolet luminosity. In contrast, optically-selected BALQSOs typically have much larger alpha_OX and so are characterised as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray sp...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... lies. A drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... that is extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  18. X-Ray Exam: Ankle

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Ankle KidsHealth > For Parents > X-Ray Exam: Ankle Print A A A Text Size ... español Radiografía: tobillo What It Is An ankle X-ray is a safe and painless test that uses ...

  19. X-Ray Exam: Finger

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Finger KidsHealth > For Parents > X-Ray Exam: Finger Print A A A Text Size ... español Radiografía: dedo What It Is A finger X-ray is a safe and painless test that uses ...

  20. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Wrist KidsHealth > For Parents > X-Ray Exam: Wrist Print A A A Text Size ... español Radiografía: muñeca What It Is A wrist X-ray is a safe and painless test that uses ...

  1. X-Ray Exam: Hip

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Hip KidsHealth > For Parents > X-Ray Exam: Hip Print A A A Text Size ... español Radiografía: cadera What It Is A hip X-ray is a safe and painless test that uses ...

  2. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Forearm KidsHealth > For Parents > X-Ray Exam: Forearm Print A A A Text Size ... español Radiografía: brazo What It Is A forearm X-ray is a safe and painless test that uses ...

  3. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Pelvis KidsHealth > For Parents > X-Ray Exam: Pelvis Print A A A Text Size ... español Radiografía: pelvis What It Is A pelvis X-ray is a safe and painless test that uses ...

  4. X-Ray Exam: Foot

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Foot KidsHealth > For Parents > X-Ray Exam: Foot Print A A A Text Size ... español Radiografía: pie What It Is A foot X-ray is a safe and painless test that uses ...

  5. X-ray today

    Energy Technology Data Exchange (ETDEWEB)

    Neitzel, U. [Philips Medical Systems, Hamburg (Germany)

    2001-09-01

    The interest attracted by the new imaging modalities tends to overshadow the continuing importance of projection radiography and fluoroscopy. Nevertheless, projection techniques still represent by far the greatest proportion of diagnostic imaging examinations, and play an essential role in the growing number of advanced interventional procedures. This article describes some of the latest developments in X-ray imaging technology, using two products from the Philips range as examples: the Integris Allura cardiovascular system with 3D image reconstruction, and the BV Pulsera: a high-end, multi-functional mobile C-arm system with cardiac capabilities. (orig.)

  6. Dosimetric characteristics of ultraviolet and x-ray-irradiated KBr:Eu2+ thermoluminescence crystals

    International Nuclear Information System (INIS)

    Thermoluminescence (TL) characteristics of KBr:Eu2+ (150 ppm) previously exposed to ultraviolet (UV) light (200 endash 300 nm) and x-ray radiation at room temperature have been determined. The TL glow curve of UV-irradiated samples is composed of six peaks located at 337, 384, 402, 435, 475, and 510 K. The TL glow curves of x-irradiated samples show mainly a TL peak around 384 K. The TL intensities of UV-irradiated (402 and 510 K glow peaks) and x-irradiated specimens present a linear dependence as a function of radiation dose as well as fading stability 300 s after irradiation. These results further enhance the possibilities of using europium-doped materials in nonionizing (actinic region) and ionizing radiation detection and dosimetry applications. copyright 1996 American Institute of Physics

  7. Dosimetric characteristics of ultraviolet and x-ray-irradiated KBr:Eu{sup 2+} thermoluminescence crystals

    Energy Technology Data Exchange (ETDEWEB)

    Melendrez, R.; Perez-Salas, R. [Programa de Posgrado en Fisica de Materiales, Centro de Investigacion, Cientifica y de Educacion Superior de Ensenada, Apartado Postal 2681, Ensenada, Baja California, 22800 (Mexico); Aceves, R.; Piters, T.M.; Barboza-Flores, M. [Centro de Investigacion en Fisica, Universidad de Sonora, Apartado Postal 5-088, Hermosillo, Sonora, 83190 (Mexico)

    1996-08-01

    Thermoluminescence (TL) characteristics of KBr:Eu{sup 2+} (150 ppm) previously exposed to ultraviolet (UV) light (200{endash}300 nm) and x-ray radiation at room temperature have been determined. The TL glow curve of UV-irradiated samples is composed of six peaks located at 337, 384, 402, 435, 475, and 510 K. The TL glow curves of x-irradiated samples show mainly a TL peak around 384 K. The TL intensities of UV-irradiated (402 and 510 K glow peaks) and x-irradiated specimens present a linear dependence as a function of radiation dose as well as fading stability 300 s after irradiation. These results further enhance the possibilities of using europium-doped materials in nonionizing (actinic region) and ionizing radiation detection and dosimetry applications. {copyright} {ital 1996 American Institute of Physics.}

  8. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  9. X-ray instrumentation for SR beamlines

    CERN Document Server

    Kovalchuk, M V; Zheludeva, S I; Aleshko-Ozhevsky, O P; Arutynyan, E H; Kheiker, D M; Kreines, A Y; Lider, V V; Pashaev, E M; Shilina, N Y; Shishkov, V A

    2000-01-01

    The main possibilities and parameters of experimental X-ray stations are presented: 'Protein crystallography', 'X-ray structure analysis', 'High-precision X-ray optics', 'X-ray crystallography and material science', 'X-ray topography', 'Photoelectron X-ray standing wave' that are being installed at Kurchatov SR source by A.V. Shubnikov Institute of Crystallography.

  10. X-ray lithography sources

    International Nuclear Information System (INIS)

    Synchrotron from dipole magnets in electron storage rings has emerged as a useful source of x-rays for lithography. To meet the need for these sources numerous groups around the world have embarked on projects to design and construct storage rings for x-ray lithography. Both conventional electromagnets as well as superconducting (SC) dipoles have been incorporated into the various designs. An overview of the worldwide effort to produce commercial x-ray sources will be presented. To better illustrate the elements involved in these sources a closer examination of the Superconducting X-ray Lithography Source Project (SXLS) at BNL will be presented. 11 refs., 1 fig., 5 tabs

  11. Soft X-ray optics

    CERN Document Server

    Spiller, Eberhard A

    1993-01-01

    This text describes optics mainly in the 10 to 500 angstrom wavelength region. These wavelengths are 50 to 100 times shorter than those for visible light and 50 to 100 times longer than the wavelengths of medical x rays or x-ray diffraction from natural crystals. There have been substantial advances during the last 20 years, which one can see as an extension of optical technology to shorter wavelengths or as an extension of x-ray diffraction to longer wavelengths. Artificial diffracting structures like zone plates and multilayer mirrors are replacing the natural crystals of x-ray diffraction.

  12. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  13. X-ray Fluorescence Sectioning

    CERN Document Server

    Cong, Wenxiang

    2012-01-01

    In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental mapping. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be ad...

  14. Radioisotope x-ray analysis

    International Nuclear Information System (INIS)

    Radioisotope x-ray fluorescence and x-ray preferential absorption (XRA) techniques are used extensively for the analysis of materials, covering such diverse applications as analysis of alloys, coal, environmental samples, paper, waste materials, and metalliferous mineral ores and products. Many of these analyses are undertaken in the harsh environment of industrial plants and in the field. Some are continuous on-line analyses of material being processed in industry, where instantaneous analysis information is required for the control of rapidly changing processes. Radioisotope x-ray analysis systems are often tailored to a specific but limited range of applications. They are simpler and often considerably less expensive than analysis systems based on x-ray tubes. These systems are preferred to x-ray tube techniques when simplicity, ruggedness, reliability, and cost of equipment are important; when minimum size, weight, and power consumption are necessary; when a very constant and predictable x-ray output is required; when the use of high-energy x-rays is advantageous; and when short x-ray path lengths are required to minimize the absorption of low-energy x-rays in air. This chapter reviews radioisotope XRF, preferential absorption, and scattering techniques. Some of the basic analysis equations are given. The characteristics of radioisotope sources and x-ray detectors are described, and then the x-ray analytical techniques are presented. The choice of radioisotope technique for a specific application is discussed. This is followed by a summary of applications of these techniques, with a more detailed account given of some of the applications, particularly those of considerable industrial importance. 79 refs., 28 figs., 7 tabs

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  16. X-ray diagnostic equipment

    International Nuclear Information System (INIS)

    An X-ray tube is connected to several different image processing devices in X-ray diagnostic equipment. Only a single organ selector is allocated to it, for which the picture parameters for each image processing device are selected. The choice of the correct combination of picture parameters is made by means of a selector switch. (DG)

  17. X-ray tube arrangement

    International Nuclear Information System (INIS)

    An x-ray tube is described incorporating an elongated target/ anode over which the electron beam is deflected and from which x-rays are emitted. Improved methods of monitoring and controlling the amplitude of the beam deflection are presented. (U.K.)

  18. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  19. X-ray diffraction apparatus

    International Nuclear Information System (INIS)

    The invention provides an x-ray diffraction apparatus permitting the rotation of the divergence sit in conjunction with the rotation of the x-ray irradiated specimen, whereby the dimensions of the x-ray irradiated portion of the specimen remain substantially constant during the rotation of the specimen. In a preferred embodiment, the divergence slit is connected to a structural element linked with a second structural element connected to the specimen such that the divergence slit rotates at a lower angular speed than the specimen

  20. Duodenal X-ray diagnostics

    International Nuclear Information System (INIS)

    The publication provides an overview of duodenal X-ray diagnostics with the aid of barium meals in 1362 patients. The introducing paragraphs deal with the topographic anatomy of the region and the methodics of X-ray investigation. The chapter entitled ''processes at the duodenum itself'' describes mainly ulcers, diverticula, congenital anomalies, tumors and inflammations. The neighbourhood processes comprise in the first place diseases having their origin at the pancreas and bile ducts. As a conclusion, endoscopic rectograde cholangio-pancreaticography and percutaneous transhepatic cholangiography are pointed out as advanced X-ray investigation methods. In the annex of X-ray images some of the described phenomena are shown in exemplary manner. (orig./MG)

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... like a photographic negative). Today, most images are digital files that are stored electronically. These stored images ... and places the x-ray film holder or digital recording plate under the table in the area ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the baby. See the Safety page for more information about pregnancy and x-rays. top of page ... procedure varies. See the Safety page for more information about radiation dose. Women should always inform their ...

  4. X-ray microtomographic scanners

    Energy Technology Data Exchange (ETDEWEB)

    Syryamkin, V. I., E-mail: klestov-simon@mail.ru; Klestov, S. A., E-mail: klestov-simon@mail.ru [National Research Tomsk State University, Tomsk, 634050 (Russian Federation)

    2015-11-17

    The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. In conclusion, the main applications of X-ray tomography are presented.

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the patient in a hospital bed or the emergency room. The x-ray tube is connected to ... equipment is relatively inexpensive and widely available in emergency rooms, physician offices, ambulatory care centers, nursing homes ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... or in bones. top of page How should I prepare? Most bone x-rays require no special ... to 10 minutes. top of page What will I experience during and after the procedure? A bone ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body absorb the x-rays in varying degrees. Dense bone absorbs much of the radiation while ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  10. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Intra-oral dental X-ray apparatus for panoramic dental radiography is described in detail. It comprises an electron gun having an elongated tubular target carrier extending into the patient's mouth. The carrier supports an inclined target for direction of an X-ray pattern towards a film positioned externally of the patient's mouth. Image definition is improved by a focusing anode which focuses the electron beam into a sharp spot (0.05 to 0.10 mm diameter) on the target. The potential on the focusing anode is adjustable to vary the size of the spot. An X-ray transmitting ceramic (oxides of Be, Al and Si) window is positioned adjacent to the front face of the target. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review and update the technique standards ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... technologist, an individual specially trained to perform radiology examinations, positions the patient on the x-ray table ... bone is forming), for comparison purposes. When the examination is complete, you may be asked to wait ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  14. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a large photographic negative). Today, most images are digital files that are stored electronically. These stored images ... and places the x-ray film holder or digital recording plate under the table in the area ...

  16. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  17. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  18. Electromechanical x-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Scott A; Platts, David; Sorensen, Eric B

    2016-05-03

    An electro-mechanical x-ray generator configured to obtain high-energy operation with favorable energy-weight scaling. The electro-mechanical x-ray generator may include a pair of capacitor plates. The capacitor plates may be charged to a predefined voltage and may be separated to generate higher voltages on the order of hundreds of kV in the AK gap. The high voltage may be generated in a vacuum tube.

  19. X-ray diagnostic apparatus

    International Nuclear Information System (INIS)

    A falling load type X-ray diagnostic apparatus comprises a low voltage power source, AC-DC converting means connected to the low voltage power source so as to apply a rectified low DC voltage, chopping means connected to the AC-DC converting means and chopping said DC voltage into a low AC voltage, high voltage applying means for transforming said low AC voltage into a high AC voltage, said high AC voltage being applied as a tube voltage to an X-ray tube from which X-rays are irradiated toward an object to be examined, means for controlling a filament heating power of the X-ray tube, programming means for supplying a control signal to said filament heating control means so as to reduce the emission current of said X-ray tube during the irradiation, and chopper control means for controlling the chopping ratio of said chopping means by evaluating said rectified DC voltage with a preset tube voltage generated in said programming means, said programming means compensating said tube voltage by receiving said control signal in such a manner that said tube voltage is maintained substantially constant during the irradiation by varying said preset tube voltage so as to control the chopping ratio based upon the reduction of the filament heating power for the X-ray tube

  20. Low energy (soft) x rays

    International Nuclear Information System (INIS)

    Dosimetry of low-energy (soft) X rays produced by the SOFTEX Model CMBW-2 was performed using Nuclear Associates Type 30 - 330 PTW, Exradin Type A2, and Shonka-Wyckoff ionization chambers with a Keithley Model 602 electrometer. Thermoluminescent (BeO chip) dosimeters were used with a Harshaw Detector 2000-A and Picoammeter-B readout system. Beam quality measurements were made using aluminum absorbers; exposure rates were assessed by the current of the X-ray tube and by exposure times. Dose distributions were established, and the average factors for non-uniformity were calculated. The means of obtaining accurate absorbed and exposed doses using these methods are discussed. Survival of V79 cells was assessed by irradiating them with soft X rays, 200 kVp X rays, and 60Co gamma rays. The relative biological effectiveness (RBE) values for soft X rays with 0, 0.2, 0.7 mm added thicknesses of aluminum were 1.6, which were compared to 60Co. The RBE of 200 kVp X rays relative to 60Co was 1.3. Results of this study are available for reference in future RERF studies of cell survival. (author)

  1. Center for X-Ray Optics, 1992

    International Nuclear Information System (INIS)

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors

  2. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  3. X-ray echo spectroscopy

    CERN Document Server

    Shvyd'ko, Yuri

    2015-01-01

    X-ray echo spectroscopy, a counterpart of neutron spin-echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x-rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1--0.02-meV ultra-high-resolution IXS applications (resolving power $> 10^8$) with broadband $\\simeq$~5--13~meV dispersing systems are introduced featuring more than $10^3$ signal e...

  4. X-ray Echo Spectroscopy.

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-26

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >10^{8}) with broadband ≃5-13  meV dispersing systems are introduced featuring more than 10^{3} signal enhancement. The technique is general, applicable in different photon frequency domains.

  5. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Intra-oral X-ray apparatus which reduces the number of exposures necessary to obtain panoramic dental radiographs is described in detail. It comprises an electron gun, a tubular target carrier projecting from the gun along the beam axis and carrying at its distal end a target surrounded by a shield of X-ray opaque material. This shield extends forward and laterally of the target and has surfaces which define a wedge or cone-shaped radiation pattern delimited vertically by the root tips of the patient's teeth. A film holder is located externally of the patient's mouth. A disposable member can fit on the target carrier to depress the patient's tongue out of the radiation pattern and to further shield the roof of the mouth. The electron beam can be magnetically deflected to change the X-ray beam direction. (author)

  6. X-ray imaging: Perovskites target X-ray detection

    Science.gov (United States)

    Heiss, Wolfgang; Brabec, Christoph

    2016-05-01

    Single crystals of perovskites are currently of interest to help fathom fundamental physical parameters limiting the performance of perovskite-based polycrystalline solar cells. Now, such perovskites offer a technology platform for optoelectronic devices, such as cheap and sensitive X-ray detectors.

  7. X-ray hot plasma diagnostics

    International Nuclear Information System (INIS)

    X-ray plasma emission study is powerful diagnostic tool of hot plasmas. In this review article the main techniques of X-ray plasma emission measurement are shortly presented: X-ray spectrometry using absorbent filters, crystal and grating spectrometers, imaging techniques using pinhole cameras, X-ray microscopes and Fresnel zone plate cameras, X-ray plasma emission calorimetry. Advances in these techniques with examples for different hot plasma devices are also presentes. (author)

  8. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Images related to X-ray (Radiography) - Bone About this Site RadiologyInfo.org is produced by: Please note ... you can search the ACR-accredited facilities database . This website does not provide cost information. The costs ...

  10. X-ray backscatter imaging

    Science.gov (United States)

    Dinca, Dan-Cristian; Schubert, Jeffrey R.; Callerame, J.

    2008-04-01

    In contrast to transmission X-ray imaging systems where inspected objects must pass between source and detector, Compton backscatter imaging allows both the illuminating source as well as the X-ray detector to be on the same side of the target object, enabling the inspection to occur rapidly and in a wide variety of space-constrained situations. A Compton backscatter image is similar to a photograph of the contents of a closed container, taken through the container walls, and highlights low atomic number materials such as explosives, drugs, and alcohol, which appear as especially bright objects by virtue of their scattering characteristics. Techniques for producing X-ray images based on Compton scattering will be discussed, along with examples of how these systems are used for both novel security applications and for the detection of contraband materials at ports and borders. Differences between transmission and backscatter images will also be highlighted. In addition, tradeoffs between Compton backscatter image quality and scan speed, effective penetration, and X-ray source specifications will be discussed.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  12. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  13. X-ray film processing

    International Nuclear Information System (INIS)

    X-ray films have to be highly sensitive, for radiation protection reasons. The films used in radiology are coated on both sides with a photosensitive emulsion. This applies to all dental films. Their properties and the development of the different exposed films are explained. (DG)

  14. X-rays and magnetism.

    Science.gov (United States)

    Fischer, Peter; Ohldag, Hendrik

    2015-09-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques.

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and easiest ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  18. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    OpenAIRE

    de Groot, F. M. F.

    2001-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption process. Section II discusses 1s X-ray absorption, i.e., the K edges, and section III deals with 2p X-ray absorption, the L edges. X-ray emission is discussed in, respectively, the L edges. X-ray emis...

  19. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2001-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption pro

  20. Center for X-Ray Optics, 1986

    International Nuclear Information System (INIS)

    The Center for X-Ray Optics has made substantial progress during the past year on the development of very high resolution x-ray technologies, the generation of coherent radiation at x-ray wavelengths, and, based on these new developments, had embarked on several scientific investigations that would not otherwise have been possible. The investigations covered in this report are topics on x-ray sources, x-ray imaging and applications, soft x-ray spectroscopy, synchrotron radiation, advanced light source and magnet structures for undulators and wigglers

  1. Soft x-ray tomoholography

    International Nuclear Information System (INIS)

    We demonstrate an x-ray imaging method that combines Fourier transform holography with tomography (‘tomoholography’) for three-dimensional (3D) microscopic imaging. A 3D image of a diatom shell with a spatial resolution of 140 nm is presented. The experiment is realized by using a small gold sphere as the reference wave source for holographic imaging. This setup allows us to rotate the sample and to collect a number of 2D projections for tomography. (paper)

  2. Soft x-ray tomoholography

    OpenAIRE

    Guehrs, E.; Stadler, A.M.; Flewett, S.; Frömmel, S.; Geilhufe, J.; Pfau, B; Rander, T.; Schaffert, S.; Büldt, G; Eisebitt, S.

    2012-01-01

    We demonstrate an x-ray imaging method that combines Fourier transform holography with tomography ('tomoholography') for three-dimensional (3D) microscopic imaging. A 3D image of a diatom shell with a spatial resolution of 140 nm is presented. The experiment is realized by using a small gold sphere as the reference wave source for holographic imaging. This setup allows us to rotate the sample and to collect a number of 2D projections for tomography.

  3. X-ray tube arrangements

    International Nuclear Information System (INIS)

    A technique for ensuring the rapid correction of both amplitude and offset errors in the deflectional movement of an electron beam along an X-ray emissive target is described. The movement is monitored at at least two positions during a sweep and differences, between the two movements and a desired movement, at these positions are combined in different proportions to produce a corrective servo signal. Such arrangements find application, for example, in computerised tomographic scanners. (author)

  4. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  5. X-ray-powered macronovae

    CERN Document Server

    Kisaka, Shota; Nakar, Ehud

    2015-01-01

    A macronova (or kilonova) was observed as an infrared excess several days after short gamma-ray burst, GRB 130603B. Although the $r$-process radioactivity is widely discussed as an energy source, it requires huge mass of ejecta from a neutron star (NS) binary merger. We propose that the X-ray excess simultaneously observed with the infrared excess can naturally heat the ejecta, leading to the thermal re-emission as observed in infrared. This X-ray-powered model explains both the X-ray and infrared excesses with a single energy source by the central engine like a black hole, and allows for broader parameter region, in particular smaller ejecta mass $\\sim10^{-3}-10^{-2}M_{\\odot}$ with iron mixed as suggested by general relativistic simulations for typical NS-NS mergers, than the previous models. We also discuss the other macronova candidates in GRB 060614 and GRB 080503, and implications for the search of electromagnetic counterparts to gravitational waves.

  6. X-Ray-powered Macronovae

    Science.gov (United States)

    Kisaka, Shota; Ioka, Kunihito; Nakar, Ehud

    2016-02-01

    A macronova (or kilonova) was observed as an infrared excess several days after the short gamma-ray burst GRB 130603B. Although the r-process radioactivity is widely discussed as an energy source, it requires a huge mass of ejecta from a neutron star (NS) binary merger. We propose a new model in which the X-ray excess gives rise to the simultaneously observed infrared excess via thermal re-emission, and explore what constraints this would place on the mass and velocity of the ejecta. This X-ray-powered model explains both the X-ray and infrared excesses with a single energy source such as the central engine like a black hole, and allows for a broader parameter region than the previous models, in particular a smaller ejecta mass ˜ {10}-3{--}{10}-2{M}⊙ and higher iron abundance mixed as suggested by general relativistic simulations for typical NS-NS mergers. We also discuss the other macronova candidates in GRB 060614 and GRB 080503, and the implications for the search of electromagnetic counterparts to gravitational waves.

  7. Aspergillosis - chest x-ray (image)

    Science.gov (United States)

    ... usually occurs in immunocompromised individuals. Here, a chest x-ray shows that the fungus has invaded the lung ... are usually seen as black areas on an x-ray. The cloudiness on the left side of this ...

  8. Stabilized x-ray generator power supply

    International Nuclear Information System (INIS)

    X-ray diffraction and X-ray fluorescence analysis are very much adopted in laboratories to determine the type and structure of the constituent compounds in solid materials, chemical composition of materials, stress developed on metals etc. These experiments need X-ray beam of fixed intensity and wave length. This can only be achieved by X-ray generator having highly stabilized tube voltage and tube current. This paper describes how X-ray tube high voltage and electron beam current are stabilized. This paper also highlights generation of X-rays, diffractometry and X-ray fluorescence analysis and their wide applications. Principle of operation for stabilizing the X-ray tube voltage and current, different protection circuits adopted, special features of the mains H.V. transformer and H.T. tank are described in this report. (author)

  9. Phase-sensitive X-ray imager

    Science.gov (United States)

    Baker, Kevin Louis

    2013-01-08

    X-ray phase sensitive wave-front sensor techniques are detailed that are capable of measuring the entire two-dimensional x-ray electric field, both the amplitude and phase, with a single measurement. These Hartmann sensing and 2-D Shear interferometry wave-front sensors do not require a temporally coherent source and are therefore compatible with x-ray tubes and also with laser-produced or x-pinch x-ray sources.

  10. Optical element for X-ray microscopy

    OpenAIRE

    Chadzitaskos, G.

    2008-01-01

    We present a proposal for a X-ray optical element suitable for X-ray microscopy and other X-ray-based display systems. Its principle is based on the Fresnel lenses condition and the Bragg condition for X-ray scattering on a slice of monocrystal. These conditions are fulfilled simultaneously due to a properly machined shape of the monocrystal with a stress at its ends.

  11. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  12. Center for X-ray Optics, 1988

    International Nuclear Information System (INIS)

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source

  13. Electron beam parallel X-ray generator

    Science.gov (United States)

    Payne, P.

    1967-01-01

    Broad X ray source produces a highly collimated beam of low energy X rays - a beam with 2 to 5 arc minutes of divergence at energies between 1 and 6 keV in less than 5 feet. The X ray beam is generated by electron bombardment of a target from a large area electron gun.

  14. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Tropical Delight: Melon Smoothie Pregnant? Your Baby's Growth X-Ray Exam: Neck KidsHealth > For Parents > X-Ray Exam: Neck Print A A A Text Size ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that uses ...

  15. X-ray tracing using Geant4

    International Nuclear Information System (INIS)

    We describe an extension to the Geant4 software package that allows it to be used as a general purpose X-ray tracing package. We demonstrate the use of our extension by building a model of the X-ray optics of the X-ray observatory XMM-Newton, calculating its effective area, and comparing the results with the published calibration curves.

  16. Protonium X-ray spectroscopy

    CERN Document Server

    Gotta, D

    1999-01-01

    The Lyman and Balmer transitions from antiprotonic hydrogen and deuterium were studied extensively at the low-energy-antiproton ring LEAR at CERN in order to determine the strong interaction effects. A first series of experiments $9 was performed with semiconductor and gaseous X-ray detectors. In the last years of LEAR operation using a Bragg crystal spectrometer, strong interaction parameters in the 2p states of antiprotonic hydrogen and deuterium were measured $9 directly. The results of the measurements support the meson-exchange models describing the medium and long range part of the nucleon-antinucleon interaction. (39 refs).

  17. X-ray tomographic apparatus

    International Nuclear Information System (INIS)

    An x-ray tomographic system consists of a radiation source such as gamma or x radiation which produces a fan-shaped beam. The fan is wide enough to encompass the patient circle. The system further includes means for rotating the radiation source about the patient for less than a full rotation, and detectors for detecting the radiation at positions that surround the patient by 1800 plus the angle of the fan beam plus the angle between adjacent fan detectors. Attenuation data from the detectors is sorted into detector fans of attenuation data, then processed. The convolved data is back-projected into an image memory and displayed on a video monitor

  18. X-ray Pulsations in the Supersoft X-ray Binary CAL 83

    OpenAIRE

    Schmidtke, P. C.; Cowley, A. P.

    2005-01-01

    X-ray data reveal that the supersoft X-ray binary CAL 83 exhibits 38.4 minute pulsations at some epochs. These X-ray variations are similar to those found in some novae and are likely to be caused by nonradial pulsations the white dwarf. This is the first detection of pulsations in a classical supersoft X-ray binary.

  19. Ionospheric effects of solar x-rays

    Science.gov (United States)

    Danskin, Donald

    2016-07-01

    The ionospheric absorption of radio waves caused by solar x-ray bursts is measured directly by Riometers from the Canada Riometer Array. The absorption is found to be proportional to the square root of the flux intensity of the X-ray burst with time delays of 18-20 seconds between the peak X-ray emission and absorption in the ionosphere. A detailed analysis showed that some X-ray flares during 2011-2014 are more effective at producing absorption than others. Solar longitude of X-ray burst for several X-class flares shows no consistent pattern of enhancement in the absorption.

  20. Comets: mechanisms of x-ray activity

    Science.gov (United States)

    Ibadov, Subhon

    2016-07-01

    Basic mechanisms of X-ray activity of comets are considered, including D-D mechanism corresponding to generation of X-rays due to production of hot short-living plasma clumps at high-velocity collisions between cometary and interplanetary dust particles as well as M-M one corresponding to production of X-rays due to recombination of multicharge ions of solar wind plasma via charge exchange process at their collisions with molecules/atoms of the cometary atmospheres. Peculiarities of the variation of the comet X-ray spectrum and X-ray luminosity with variation of its heliocentric distance are revealed.

  1. Swift Observations of X-ray supernovae

    OpenAIRE

    Li, K. L.; Pun, Chun. S. J.

    2011-01-01

    We present a result of X-ray supernovae (SNe) survey using the Swift satellite public archive. An automatic searching program was designed to search X-ray SNe among all of the Swift archival observations between November 2004 and February 2011. Using the C++ program, 24 X-ray detectable supernovae have been found in the archive and 3 of them were newly-discovered in X-rays which are SN 1986L, SN 2003lx, and SN 2007od. In addition, SN 2003lx is a Type Ia supernova which may be the second X-ray...

  2. Symbiotic stars in X-rays

    OpenAIRE

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K; Nelson, T.

    2012-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of nine white dwarf symbiotics that were not previously known to be X-ray sources and one that had previously been detected as a supersoft X-ray source. The nine new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbi...

  3. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics

    OpenAIRE

    Sun, Tianxi; MacDonald, C. A.

    2013-01-01

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  4. X-Ray Attenuation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Toor, A.

    2000-03-03

    To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3rd-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intensity by many orders of magnitude without increasing the pulse-to-pulse variation. In this report we consider a possible solution for controlled attenuation of the LCLS x-ray radiation. We suggest using for this purpose a windowless gas-filled cell with the differential pumping. Although this scheme is easily realizable in principle, it has to be demonstrated that the attenuator can be made short enough to be practical and that the gas loads delivered to the vacuum line of sight (LOS) are acceptable. We are not going to present a final, optimized design. Instead, we will provide a preliminary analysis showing that the whole concept is robust and is worth further study. The spatial structure of the LCLS x-ray pulse at the location of the attenuator is shown in Fig. 1. The central high-intensity component, due to the FEL, has a FWHM of {approx}100 {micro}m. A second component, due to the undulator's broad band spontaneous radiation is seen as a much lower intensity ''halo'' with a FWHM of 1 mm. We discuss two versions of the attenuation cell. The first is directed towards a controlled attenuation of the FEL up to the 4 orders of magnitude in the intensity, with the spontaneous radiation halo being eliminated by collimators. In the second version, the spontaneous radiation is not sacrificed but the FEL component (as well as the first harmonic of the spontaneous radiation) gets attenuated by a more modest factor up to 100. We will make all the estimates assuming that the gas used in the attenuator is Xenon and that the energy of the FEL is 8.25 keV. At

  5. X-ray intensifying screens

    International Nuclear Information System (INIS)

    An x-ray intensifying screen comprises a support which has a luminescent composition comprising an isotropic phosphor and a polymer having an index of refraction within 0.02 of that of the phosphor over at least 80 percent of its emission spectrum. The support has an index of refraction up to or equal to 0.05 units higher than that of the phosphor and has a reflection optical density of at least 1.7 to light emitted by the phosphor. A preferred luminescent composition comprises Kl:Tl, Rbl:Tl at BaSrFCl:Eu mixed with two monomers such as 1-naphthylmethylmethacrylate, S(1-naphthylmethyl) thioacrylate, 1-bromo-2-naphthylacrylate, and benzyl methacrylate, coated on black anodised Al and polymerised in situ. The ratio of monomers is adjusted to give the desired refractive index. Other phosphors, polymers and supports are specified together with the preparation of the monomers and polymers. (author)

  6. X-ray flat panel detectors and X-ray tubes contributing to development of X-ray diagnostic systems

    International Nuclear Information System (INIS)

    X-ray flat panel detectors (FPDs) and X-ray tubes are key devices allowing X-ray diagnostic systems to support more sophisticated medical care. FPDs provide valuable information for the diagnosis of various diseases through the conversion of X-ray images of the human body into electronic signals, while X-ray tubes are used in a wide range of applications such as computed tomography (CT), angiography, fluoroscopy, mammography, and dental systems. Toshiba Electron Tubes and Devices Co., Ltd. has developed and commercialized FPDs providing high-quality diagnostic X-ray images with low dose exposure through the development of cutting-edge technologies including a fine crystal formation technology for cesium iodide (CsI) scintillators, thin-film transistor (TFT) arrays with photodiodes, and so on. In the field of X-ray tubes that can generate a high output of X-rays, we have developed a liquid metal hydrodynamic bearing (LM bearing) technology for various diagnostic systems including medical CT systems with a long lifetime and high rotation speed, and cardiovascular imaging systems with quiet operation. Furthermore, LM bearing technology reduces the burden on the environment by replacing insulating oil with water coolant for the cooling system and making the X-ray tubes more compact. (author)

  7. Soft x-ray interferometry

    International Nuclear Information System (INIS)

    The purpose of the soft x-ray interferometry workshop held at Lawrence Berkeley Laboratory was to discuss with the scientific community the proposed technical design of the soft x-ray Fourier-transform spectrometer being developed at the ALS. Different design strategies for the instrument's components were discussed, as well as detection methods, signal processing issues, and how to meet the manufacturing tolerances that are necessary for the instrument to achieve the desired levels of performance. Workshop participants were encouraged to report on their experiences in the field of Fourier transform spectroscopy. The ALS is developing a Fourier transform spectrometer that is intended to operate up to 100 eV. The motivation is solely improved resolution and not the throughput (Jaquinot) or multiplex (Fellgett) advantage, neither of which apply for the sources and detectors used in this spectral range. The proposed implementation of this is via a Mach-Zehnder geometry that has been (1) distorted from a square to a rhombus to get grazing incidence of a suitable angle for 100 eV and (2) provided with a mirror-motion system to make the path difference between the interfering beams tunable. The experiment consists of measuring the emergent light intensity (I(x)) as a function of the path difference (x). The resolving power of the system is limited by the amount of path difference obtainable that is 1 cm (one million half-waves at 200 angstrom wavelength) in the design thus allowing a resolving power of one million. The free spectral range of the system is limited by the closeness with which the function I(x) is sampled. It is proposed to illuminate a helium absorption cell with roughly 1%-band-width light from a monochromator thus allowing one hundred aliases without spectral overlap even for sampling of I(x) at one hundredth of the Nyquist frequency

  8. Soft x-ray polarimeter laboratory tests

    Science.gov (United States)

    Murphy, Kendrah D.; Marshall, Herman L.; Schulz, Norbert S.; Jenks, Kevin; Sommer, Sophie J. B.; Marshall, Eric A.

    2010-07-01

    Multilayer-coated optics can strongly polarize X-rays and are central to a new design of a broad-band, soft X-ray polarimeter. We have begun laboratory work to verify the performance of components that could be used in future soft X-ray polarimetric instrumentation. We have reconfigured a 17 meter beamline facility, originally developed for testing transmission gratings for Chandra, to include a polarized X-ray source, an X-ray-dispersing transmission grating, and a multilayer-coated optic that illuminates a CCD detector. The X-rays produced from a Manson Model 5, multi-anode source are polarized by a multilayer-coated flat mirror. The current configuration allows for a 180 degree rotation of the source in order to rotate the direction of polarization. We will present progress in source characterization and system modulation measurements as well as null and robustness tests.

  9. X-rays for medical use

    Science.gov (United States)

    Hessenbruch, A.

    1995-11-01

    1995 is the centenary of the discovery of X-rays by the German physicist Wilhelm C Rontgen. In the past hundred years, the new rays have developed from being unknown to finding application in many walks of life, not least in medicine. This is so much so that in common speech the word `x-ray` refers not to a form of radiation but to an X-ray photograph taken for the purposes of diagnosis (as in: `I had an X-ray done to see if my leg was broken`). X-rays are now used routinely, and they are used both for diagnosis and for therapy. This paper will give an outline of the use of X-rays in medicine throughout our present century.

  10. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  11. X-ray microlaminography with polycapillary optics

    Energy Technology Data Exchange (ETDEWEB)

    Dabrowski, K. M.; Dul, D. T.; Wrobel, A.; Korecki, P. [Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Krakow (Poland)

    2013-06-03

    We demonstrate layer-by-layer x-ray microimaging using polycapillary optics. The depth resolution is achieved without sample or source rotation and in a way similar to classical tomography or laminography. The method takes advantage from large angular apertures of polycapillary optics and from their specific microstructure, which is treated as a coded aperture. The imaging geometry is compatible with polychromatic x-ray sources and with scanning and confocal x-ray fluorescence setups.

  12. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  13. Applications of soft x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, C.H.

    1993-08-01

    The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed.

  14. X-ray spot film device

    International Nuclear Information System (INIS)

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  15. X-ray data booklet. Revision

    International Nuclear Information System (INIS)

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities

  16. Topological X-Rays and MRIs

    Science.gov (United States)

    Lynch, Mark

    2002-01-01

    Let K be a compact subset of the interior of the unit disk D in the plane and suppose one can't see through the boundary of D and identify K. However, assume that one can take "topological X-rays" of D which measure the "density" of K along the lines of the X-rays. By taking these X-rays from all directions, a "topological MRI" is generated for…

  17. Observation of femtosecond X-ray interactions with matter using an X-ray-X-ray pump-probe scheme.

    Science.gov (United States)

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru; Yabashi, Makina

    2016-02-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼10(19) W/cm(2)) XFEL pulses. An X-ray pump-probe diffraction scheme was developed in this study; tightly focused double-5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray-induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray-matter interactions. The X-ray pump-probe scheme demonstrated here would be effective for understanding ultraintense X-ray-matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities.

  18. Advanced X-ray diffractive optics

    OpenAIRE

    Vila-Comamala, J.; Jefimovs, K.; Pilvi, T.; Ritala, M; Sarkar, S S; Solak, H H; Guzenko, V.A.; Stampanoni, M.; Marone, F.; J. Raabe; G. Tzvetkov; Fink, R H; Grolimund, D.; Borca, C.N.; Kaulich, B

    2009-01-01

    X-ray microscopy greatly bene�ts from the advances in x-ray optics. At the Paul Scherrer Institut, developments in x-ray di�ractive optics include the manufacture and optimization of Fresnel zone plates (FZPs) and di�ractive optical elements for both soft and hard x-ray regimes. In particular, we demonstrate here a novel method for the production of ultra-high resolution FZPs. This technique is based on the deposition of a zone plate material (iridium) onto the sidewalls of a p...

  19. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  20. The Lunar X-ray Observatory (LXO)

    Science.gov (United States)

    Porter, F. Scott

    2008-01-01

    X-ray emission from charge exchange recombination between the highly ionized solar wind and neutral material i n Earth's magnetosheath has complicated x-ray observations of celestial objects with x-ray observatories including ROSAT, Chandra, XMM-Newton, and Suzaku. However, the charge-exchange emission can also be used as an important diagnostic of the solar-wind interacting with the magnetosheath. Soft x-ray observations from low-earth orbit or even the highly eccentric orbits of Chandra and XMM-Newton are likely superpositions of the celestial object of interest, the true extra-solar soft x-ray background, geospheric charge exchange, and heliospheric charge exchange. We show that with a small x-ray telescope placed either on the moon, in a similar vein as the Apollo ALSOP instruments, or at a stable orbit near L1, we can begin t o disentangle the complicated emission structure in the soft x-ray band. Here we present initial results of a feasibility study recently funded by NASA t o place a small x-ray telescope on the lunar surface. The telescope operates during lunar night to observe charge exchange interactions between the solar wind and magnetospheric neutrals, between the solar wind and the lunar atmosphere, and an unobstructed view of the soft x-ray background without the geospheric component.

  1. Ultrashort X-ray pulse science

    International Nuclear Information System (INIS)

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90o Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ∼ 300 fs, 30 keV (0.4 (angstrom)) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been

  2. X-ray pulsar rush in 1998

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, K.; Tsujimoto, K.; Nishiuchi, Mamiko; Yokogawa, J.; Koyama, K. [Kyoto Univ., Faculty of Science, Kyoto (Japan)

    1999-08-01

    We present recent remarkable topics about discoveries of X-ray pulsars. 1. Pulsations from two Soft Gamma-ray Repeaters: These pulsars have enormously strong magnetic field (B {approx} 10{sup 15} G), thus these are called as 'magnetar', new type of X-ray pulsars. 2. New Crab-like pulsars: These discoveries lead to suggesting universality of Crab-like pulsars. 3. An X-ray bursting millisecond pulsar: This is strong evidence for the recycle theory of generating radio millisecond pulsars. 4. X-ray pulsar rush in the SMC: This indicates the younger star formation history in the SMC. (author)

  3. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90{sup o} Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated {approx} 300 fs, 30 keV (0.4 {angstrom}) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has

  4. Imaging with x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva, L.B.; Cauble, B.; Frieders, G.; Koch, J.A.; MacGowan, B.J.; Matthews, D.L.; Mrowka, S.; Ress, D.; Trebes, J.E.; Weiland, T.L.

    1993-11-01

    Collisionally pumped soft x-ray lasers now operate over a wavelength range extending from 35--300 {Angstrom}. These sources have high peak brightness and are now being utilized for x-ray imaging and plasma interferometry. In this paper we will describe our efforts to probe long scalelength plasmas using Moire deflectrometry and soft x-ray imaging. The progress in the development of short pulse x-ray lasers using a double pulse irradiation technique which incorporates a travelling wave pump will also be presented.

  5. X-ray Emission from Elliptical Galaxies

    OpenAIRE

    Sarazin, Craig L.

    1996-01-01

    Elliptical galaxies are generally luminous sources of X-ray radiation, and contain large amounts of hot, interstellar gas. In the brighter X-ray galaxies, the inferred masses of hot gas are consistent with those expected given the present rates of stellar mass loss. The required rates of heating of the gas are also roughly consistent with those expected from the motions of gas losing stars. X-ray observations, particularly X-ray spectra, require a low rate of Type Ia supernova heating and che...

  6. X-ray Observations of Planetary Nebulae

    OpenAIRE

    Guerrero, M. A.; Chu, Y.-H.; Gruendl, R A

    2003-01-01

    Planetary nebulae (PNe) are an exciting addition to the zoo of X-ray sources. Recent Chandra and XMM-Newton observations have detected diffuse X-ray emission from shocked fast winds in PN interiors as well as bow-shocks of fast collimated outflows impinging on the nebular envelope. Point X-ray sources associated with PN central stars are also detected, with the soft X-ray (>0.5 keV) emission from instability shocks in the fast stellar wind itself or from a low-mass companion's coronal activit...

  7. X-ray pulsars: a review

    CERN Document Server

    Caballero, I

    2012-01-01

    Accreting X-ray pulsars are among the most luminous objects in the X-ray sky. In highly magnetized neutron stars (B~10^12 G), the flow of matter is dominated by the strong magnetic field. The general properties of accreting X-ray binaries are presented, focusing on the spectral characteristics of the systems. The use of cyclotron lines as a tool to directly measure a neutron star's magnetic field and to test the theory of accretion are discussed. We conclude with the current and future prospects for accreting X-ray binary studies.

  8. Hard X-ray Modulation Telescope

    Institute of Scientific and Technical Information of China (English)

    LU Fangjun

    2011-01-01

    The Hard X-ray Modulation Telescope (HXMT) will be China's first astronomical satellite. On board HXMT there are three kinds of slat-collimated telescopes, the High Energy X-ray Telescope (HE, 20-250 keV, 5000 cm^2), the Medium Energy X-ray Telescope (ME, 5-30 keV, 952 cm^2), and the Low Energy X-ray Telescope (LE, 1-15 keV, 384 cm^2).

  9. X-rays from the youngest stars

    Science.gov (United States)

    Feigelson, Eric D.

    1994-01-01

    The X-ray properties of classical and weak-lined T Tauri stars are briefly reviewed, emphasizing recent results from the ROSAT satellite and prospects for ASCA. The interpretation of the high level of T Tauri X-rays as enhanced solar-type magnetic activity is discussed and criticized. The census of X-ray emitters is significantly increasing estimates of galactic star formation efficiency, and X-ray emission may be important for self-regulation of star formation. ASCA images will detect star formation regions out to several kiloparsecs and will study the magnetically heated plasma around T Tauri stars. However, images will often suffer from crowding effects.

  10. X-ray imaging using a tunable coherent X-ray source based on parametric X-ray radiation

    International Nuclear Information System (INIS)

    A novel X-ray source based on parametric X-ray radiation (PXR) has been employed for X-ray imaging at the Laboratory for Electron Beam Research and Application (LEBRA), Nihon University. Notable features of PXR are tunable energy, monochromaticity with spatial chirp, narrow local bandwidth and spatial coherence. Since the X-ray beam from the PXR system has a large irradiation area with uniform flux density, the PXR-based source is suited for X-ray imaging, especially for application to phase-contrast imaging. Despite the cone-like X-ray beam, diffraction-enhanced imaging (DEI) can be employed as a phase contrast imaging technique. DEI experiments were performed using 14- to 34-keV X-rays and the phase-gradient images were obtained. The results demonstrated the capability of PXR as an X-ray source for phase-contrast imaging with a large irradiation field attributed to the cone-beam effect. Given the significant properties of the LEBRA-PXR source, the result suggests the possible construction of a compact linac-driven PXR-Imaging instrument and its application to medical diagnoses

  11. On the universal X-ray luminosity function of binary X-ray sources in galaxies

    OpenAIRE

    Postnov, K. A.

    2002-01-01

    The empirically determined universal power-law shape of X-ray luminosity function of high mass X-ray binaries in galaxies is explained by fundamental mass-luminosity and mass-radius relations for massive stars.

  12. SN X-ray Progenitor?

    Science.gov (United States)

    2008-01-01

    Identifying stars that explode, right before they explode, is a tricky proposition since the end of starlife comes swiftly: in thermonuclear deflagrations, in nuclear exhaustion, or maybe in a rapid swirling merger of two dead stellar cores. On the right in the image above is an image of the galaxy NGC 1404 taken by the UV/optical Telescope (UVOT) on the Swift observatory. The circle surrounds SN 2007on, a supernova of Type Ia produced by the explosion of a white dwarf star in a binary system. These types of supernovae are important since they are believed to be 'standard candles', events which have the same intrinsic brightness which can serve as an important yardstick to measure cosmic distances. On the left is an image of the same galaxy taken by the Chandra X-ray observatory four years before the supernova. Conspicuous in the SN source circle is a bright source in the Chandra image, believed to be emission from a compact object+normal star companion: a similar system to the supposed precursor of SN 2007on. If true this would be the first time a Type Ia supernova precursor has ever been seen. But astronomers are still debating whether the Chandra source really is the precursor or not; it seems there's a slight but significant difference in the location of the Chandra source and the supernova. Stay tuned for more developments.

  13. X-ray radiography facility

    International Nuclear Information System (INIS)

    The paper described a radiographic apparatus containing a radiation source, a diaphragm with collimating windows and a cassette holder with a cassette for the X-ray film. In order to increase the efficiency and quality of monitoring, the diaphragm and the cassette are made in the form of cylindrical shells, the centre of curvature of which coincides with the position of the radiation source focus. Each collimating window of the diaphragm is made in the form of two coaxially connected truncated cones, joined at the large bases in such a way that the angle at the vertex of the cone nearer the source is not less than the central angle with the vertex at the focus of the radiation source supported by the larger base, and 15-300 less than the angle at the vertex of the cone further from the source. By this means monitoring efficiency is increased by a factor of 1.5-2 and the quality of the radiographs improved. The apparatus is used for flaw detection in cylindrical objects. (author)

  14. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  15. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  16. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  17. X-ray topography and multiple diffraction

    International Nuclear Information System (INIS)

    A short summary on X-ray topography, which is based on the dynamical theory of X-ray diffraction, is made. The applications and properties related to the use of the multiple diffraction technique are analized and discussed. (L.C.)

  18. Soft x rays for radiobiological studies

    International Nuclear Information System (INIS)

    Lethal effects and chromosome aberrations induced in cells exposed to low energy (soft) X rays demonstrated that these relatively low energy X rays are just as effective as those of higher energy for radiobiological studies, and even more effective for irradiating cultured mammalian cells than laboratory animals. (author)

  19. Coccidioidomycosis - chest x-ray (image)

    Science.gov (United States)

    This chest x-ray shows the affects of a fungal infection, coccidioidomycosis. In the middle of the left lung (seen on the ... defined borders. Other diseases that may explain these x-ray findings include lung abscesses, chronic pulmonary tuberculosis, chronic ...

  20. X-Ray Detection Visits the Classroom

    Science.gov (United States)

    Peralta, Luis; Farinha, Ana; Pinto, Ana

    2008-01-01

    Film has been used to detect x-rays since the early days of their discovery by Rontgen. Although nowadays superseded by other techniques, film still provides a cheap means of x-ray detection, making it attractive in high-school or undergraduate university courses. If some sort of quantitative result is required, the film's optical absorbance or…

  1. Adenocarcinoma - chest x-ray (image)

    Science.gov (United States)

    This chest x-ray shows adenocarcinoma of the lung. There is a rounded light spot in the right upper lung (left side ... density. Diseases that may cause this type of x-ray result would be tuberculous or fungal granuloma, and ...

  2. Tracing the X-Ray Trail

    Science.gov (United States)

    What you need to know about… Tracing the X-ray Trail If you’ve just completed an x-ray, computed tomography (CT), magnetic resonance (MR) Start here! or other diagnostic imaging procedure, you probably want to know when you will ... los rayos X Si acaba de hacerse una radiografía, tomografía ¡Empezar ...

  3. Proton induced X-ray emission analysis

    International Nuclear Information System (INIS)

    The developments in proton induced X-ray emission analysis are reviewed. Techniques for analyzing thick and thin samples of different origin are described. Discussions on the application of proton induced X-ray emission analysis in different fields, comparison of the sensitivity of this method with other analytical techniques, its limitations and possible improvements are presented

  4. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan;

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positione...

  5. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    This thesis presents thework on combining complementary X-rays techniques for studying the structures of proteins and other biomaterials, and consists of three different projects: (i) Characterization of protein powders with X-ray powder diffraction (XRPD). (ii) The combination of X-ray crystallo...

  6. Soft X-Ray Spectra of AGN Discovered Via Their Hard X-Ray

    Science.gov (United States)

    Schwartz, Daniel

    1998-01-01

    This final report is a study of the Active Galactic Nuclei (AGN). Investigation of the soft x-ray spectra of AGN were performed by using their hard x-ray emission. ROSAT observations of AGN was also performed, which allowed for the study of these x-ray spectra and the structures of 7 clusters of galaxies.

  7. X-ray devices contributing to sophistication of X-ray diagnostic systems

    International Nuclear Information System (INIS)

    X-ray tubes to generate X-rays, as well as X-ray image intensifiers (I.I.s) and X-ray flat panel detectors (FPDs) to convert X-ray images into electronic signals, are key devices in X-ray diagnostic systems, which are playing a major role in the advancement of diagnosis and treatment. Toshiba Electron Tubes and Devices Co., Ltd. has been offering optimal products incorporating the most advanced technologies to customers through continuous technological innovations. These include a high-sensitivity technology for X-ray I.I.s and X-ray FPDs to suppress patient exposure doses, a focal spot design technology for X-ray tubes and high-resolution technologies for X-ray I.I.s and X-ray FPDs that enhance image quality and make it possible to detect smaller lesion areas, and a noise reduction technology for X-ray tubes to realize a comfortable medical environment with reduced stress on both patients and medical staff. (author)

  8. An X-ray view of quasars

    CERN Document Server

    Singh, K P

    2013-01-01

    I present an overview of observational studies of quasars of all types, with particular emphasis on X-ray observational studies. The presentation is based on the most popularly accepted unified picture of quasars - collectively referred to as AGN (active galactic nuclei) in this review. Characteristics of X-ray spectra and X-ray variability obtained from various X-ray satellites over the last 5 decades have been presented and discussed. The contribution of AGN in understanding the cosmic X-ray background is discussed very briefly. Attempt has been made to provide up-to-date information; however, this is a vast subject and this presentation is not intended to be comprehensive.

  9. X-ray Fourier ptychographic microscopy

    CERN Document Server

    Simons, H; Guigay, J P; Detlefs, C

    2016-01-01

    Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution, wide field of view images into a high-resolution image. In the x-ray range this opens the possibility to overcome the limited numerical aperture of existing x-ray lenses. Furthermore, digital wave front correction (DWC) may be used to charaterize and correct lens imperfections. Given the diffraction limit achievable with x-ray lenses (below 100 nm), x-ray Fourier ptychographic microscopy (XFPM) should be able to reach resolutions in the 10 nm range.

  10. High Energy Vision: Processing X-rays

    CERN Document Server

    DePasquale, Joseph; Edmonds, Peter

    2015-01-01

    Astronomy is by nature a visual science. The high quality imagery produced by the world's observatories can be a key to effectively engaging with the public and helping to inspire the next generation of scientists. Creating compelling astronomical imagery can, however, be particularly challenging in the non-optical wavelength regimes. In the case of X-ray astronomy, where the amount of light available to create an image is severely limited, it is necessary to employ sophisticated image processing algorithms to translate light beyond human vision into imagery that is aesthetically pleasing while still being scientifically accurate. This paper provides a brief overview of the history of X-ray astronomy leading to the deployment of NASA's Chandra X-ray Observatory, followed by an examination of the specific challenges posed by processing X-ray imagery. The authors then explore image processing techniques used to mitigate such processing challenges in order to create effective public imagery for X-ray astronomy. ...

  11. X-Rays from Green Pea Analogs

    Science.gov (United States)

    Brorby, Matthew

    2014-09-01

    X-rays may have contributed to the heating and reionization of the IGM in the early universe. High mass X-ray binaries (HMXB) within small, low-metallicity galaxies are expected to be the main source of X-rays at this time. Since studying these high-redshift galaxies is currently impossible, we turn to local analogs that have the same properties the galaxies in the early are expected to have. A number of recent studies have shown an enhanced number of HMXBs in nearby low metallicity galaxies. We propose to observe a sample of metal-deficient luminous compact galaxies (LCG) in order to determine if the X-ray luminosity is enhanced relative to SFR, thereby providing further evidence to the importance of X-rays in the early universe.

  12. The X-ray imager on AXO

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan; Westergaard, Niels Jørgen Stenfeldt;

    2001-01-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated....... Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray...... Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active...

  13. Sequencing degraded DNA from non-destructively sampled museum specimens for RAD-tagging and low-coverage shotgun phylogenetics.

    Directory of Open Access Journals (Sweden)

    Mandy Man-Ying Tin

    Full Text Available Ancient and archival DNA samples are valuable resources for the study of diverse historical processes. In particular, museum specimens provide access to biotas distant in time and space, and can provide insights into ecological and evolutionary changes over time. However, archival specimens are difficult to handle; they are often fragile and irreplaceable, and typically contain only short segments of denatured DNA. Here we present a set of tools for processing such samples for state-of-the-art genetic analysis. First, we report a protocol for minimally destructive DNA extraction of insect museum specimens, which produced sequenceable DNA from all of the samples assayed. The 11 specimens analyzed had fragmented DNA, rarely exceeding 100 bp in length, and could not be amplified by conventional PCR targeting the mitochondrial cytochrome oxidase I gene. Our approach made these samples amenable to analysis with commonly used next-generation sequencing-based molecular analytic tools, including RAD-tagging and shotgun genome re-sequencing. First, we used museum ant specimens from three species, each with its own reference genome, for RAD-tag mapping. Were able to use the degraded DNA sequences, which were sequenced in full, to identify duplicate reads and filter them prior to base calling. Second, we re-sequenced six Hawaiian Drosophila species, with millions of years of divergence, but with only a single available reference genome. Despite a shallow coverage of 0.37 ± 0.42 per base, we could recover a sufficient number of overlapping SNPs to fully resolve the species tree, which was consistent with earlier karyotypic studies, and previous molecular studies, at least in the regions of the tree that these studies could resolve. Although developed for use with degraded DNA, all of these techniques are readily applicable to more recent tissue, and are suitable for liquid handling automation.

  14. X-ray Spectral Variation of Eta Carinae through the 2003 X-ray Minimum

    OpenAIRE

    Hamaguchi, Kenji; Corcoran, Michael F.; Gull, Theodore; Ishibashi, Kazunori; Pittard, Julian M.; Hillier, D. John; Damineli, Augusto; Davidson, Kris; Nielsen, Krister E.; Kober, Gladys Vieira

    2007-01-01

    We report the results of an X-ray observing campaign on the massive, evolved star Eta Carinae, concentrating on the 2003 X-ray minimum as seen by the XMM-Newton observatory. These are the first spatially-resolved X-ray monitoring observations of the stellar X-ray spectrum during the minimum. The hard X-ray emission, believed to be associated with the collision of Eta Carinae's wind with the wind from a massive companion star, varied strongly in flux on timescales of days, but not significantl...

  15. Large area soft x-ray collimator to facilitate x-ray optics testing

    Science.gov (United States)

    Espy, Samuel L.

    1994-01-01

    The first objective of this program is to design a nested conical foil x-ray optic which will collimate x-rays diverging from a point source. The collimator could then be employed in a small, inexpensive x-ray test stand which would be used to test various x-ray optics and detector systems. The second objective is to demonstrate the fabrication of the x-ray reflectors for this optic using lacquer-smoothing and zero-stress electroforming techniques.

  16. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline

    Institute of Scientific and Technical Information of China (English)

    DENG Biao; YANG Qun; XIE Hong-Lan; DU Guo-Hao; XIAO Wi-Qiao

    2011-01-01

    X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF X-ray imaging beamline (BL13W1) are described. The test samples were investigated and the 2D elemental image was reconstructed using a filtered back-projection algorithm. In the sample the element Cd was observed. Up to now, the X-ray fluorescence CT could be carried out at the SSRF X-ray imaging beamline.

  17. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    OpenAIRE

    Miaja-Avila, L.; G. C. O'Neil; Uhlig, J.; C. L. Cromer; Dowell, M. L.; Jimenez, R.; Hoover, A. S.; Silverman, K. L.; Ullom, J. N.

    2015-01-01

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary opti...

  18. Dual-energy X-ray CT and the extension to polychromatic X-ray CT

    International Nuclear Information System (INIS)

    We have developed dual energy X-ray CT using monochromatic X-ray beams. From the dual-energy X-ray CT, we can obtain distributions of an electron density and an effective atomic number in a human body. Especially, the electron density is very important for the heavy ion radiotherapy. Now, we adopted new array-detector to know the energy of incident photons as well as detect the position and the number of photons. We carry out the experiment of the dual-energy X-ray CT at the beamline of KEK and SPring-8 as a fundamental study for the polychromatic X-ray CT. We will show the preliminary result of this experiments and the feasibility of a quantitative polychromatic X-ray CT as an advanced method of monochromatic X-ray CT in this study. (author)

  19. Cell survival studies using ultrasoft x rays

    International Nuclear Information System (INIS)

    Cell survival was studied for V79 hamster, 10T1/2 mouse, and human skin fibroblast cell lines, using carbon K (0.28 keV), copper K (8.0 keV), and 250 kVp x rays. Because of the rapid attenuation of the carbon x rays, cellular dimensions at the time of exposure were measured using optical and electron microscopy, and frequency distributions of mean dose absorbed by the cell nucleus were obtained. The results indicate that the differences in cell killing between ultra-soft and hard x rays may depend on the nuclear thickness of the cells. Studies of the effects of hypoxia on V79 and 10T1/2 cells using carbon K, aluminum K (1.5 keV), and copper K x rays show decreasing OER values with decreasing x-ray energy and no difference between the two cell lines. Age response studies with V79 cells show similar cell-cycle variation of survival for carbon K and aluminum K x rays as for hard x rays

  20. Toward Adaptive X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Tim W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peer; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffrey J.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Rodriguez Sanmartin, Daniel; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2011-01-01

    Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

  1. Toward active x-ray telescopes

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Timothy W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peter; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffery J.; Michette, Alan G.; Ramsey, Brian D.; Reid, Paul B.; Rodriguez Sanmartin, Daniel; Saha, Timo T.; Schwartz, Daniel A.; Trolier-McKinstry, Susan; Wilke, Rudeger H. T.; Willingale, Richard; Zhang, William W.

    2011-09-01

    Future x-ray observatories will require high-resolution ( 25 m2) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the areal density of the grazing-incidence mirrors to about 1 kg/m2 or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve active (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, active optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom (UK) and the Generation-X (Gen-X) concept studies in the United States (US). This paper discusses relevant technological issues and summarizes progress toward active x-ray telescopes.

  2. 78 FR 100 - Guidance for Industry and Food and Drug Administration Staff; Refuse To Accept Policy for 510(k)s...

    Science.gov (United States)

    2013-01-02

    ... HUMAN SERVICES Food and Drug Administration Guidance for Industry and Food and Drug Administration Staff; Refuse To Accept Policy for 510(k)s; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing the availability of the...

  3. 21 CFR 880.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 880.9 Section 880.9 Food and Drugs FOOD AND DRUG... Food, Drug, and Cosmetic Act (the act). The exemption from the requirement of premarket...

  4. 21 CFR 884.9 - Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act). 884.9 Section 884.9 Food and Drugs FOOD AND DRUG..., and Cosmetic Act (the act). The exemption from the requirement of premarket notification (section...

  5. Two-dimensional x-ray diffraction

    CERN Document Server

    He, Bob B

    2009-01-01

    Written by one of the pioneers of 2D X-Ray Diffraction, this useful guide covers the fundamentals, experimental methods and applications of two-dimensional x-ray diffraction, including geometry convention, x-ray source and optics, two-dimensional detectors, diffraction data interpretation, and configurations for various applications, such as phase identification, texture, stress, microstructure analysis, crystallinity, thin film analysis and combinatorial screening. Experimental examples in materials research, pharmaceuticals, and forensics are also given. This presents a key resource to resea

  6. Imaging Cellular Architecture with X-rays

    OpenAIRE

    Larabell, Carolyn A.; Nugent, Keith A.

    2010-01-01

    X-ray imaging of biological samples is progressing rapidly. In this paper we review the progress to date in high resolution imaging of cellular architecture. In particular we survey the progress in soft X-ray tomography and argue that the field is coming of age and that important biological insights are starting to emerge. We then review the new ideas based on coherent diffraction. These methods are at a much earlier stage of development but, as they eliminate the need for X-ray optics, have ...

  7. The Future of X-Ray Optics

    Science.gov (United States)

    Weisskopf, Martin C.

    2013-01-01

    The most important next step is the development of X-ray optics comparable to (or better than) Chandra in angular resolution that far exceed Chandra s effective area. Use the long delay to establish an adequately funded, competitive technology program along the lines I have recommended. Don't be diverted from this objective, except for Explorer-class missions. Progress in X-ray optics, with emphasis on the angular resolution, is central to the paradigm-shifting discoveries and the contributions of X-ray astronomy to multiwavelength astrophysics over the past 51 years.

  8. Ten years of X-ray interferometry

    International Nuclear Information System (INIS)

    X-ray interferometers were the first optical instruments which utilized many Bragg reflecting components in monolithic blocks of perfect crystal. They have made important contributions to our knowledge of fundamental constants, of Bragg reflection x-ray optics, of strains and defects in crystals and of the optical constants of materials in the x-ray region of the electromagnetic spectrum. Based on an oversimplified optical analogue, their mode of operation is described in detail. Current applications of crystal interferometers and future work is briefly reviewed. (author)

  9. X-ray phase-contrast methods

    Energy Technology Data Exchange (ETDEWEB)

    Lider, V. V., E-mail: lider@ns.crys.ras.ru; Kovalchuk, M. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2013-11-15

    This review is devoted to a comparative description of the methods for forming X-ray phase-contrast images of weakly absorbing (phase) objects. These include the crystal interferometer method, the Talbot interferometer method, diffraction-enhanced X-ray imaging, and the in-line method. The potential of their practical application in various fields of science and technology is discussed. The publications on the development and optimization of X-ray phase-contrast methods and the experimental study of phase objects are analyzed.

  10. Microfabrication of hard x-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik

    in the vertical and horizontal directions was addressed. A functioning prototype of a 2D silicon objective for use in a bright-field hard-XRM was demonstrated. The results are promising; showing acceptably low aberration and performance close to theoretical expectations. A resolution of 300 nm with 17 keV x...... rate larger than 10 pieces per hour indicates the economic value of injection molded x-ray lenses, which may have applications in more readily available small laboratory x-ray instruments or medical devices. In each case, observed non-uniformities of the shaped x-ray beams were investigated and found...

  11. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy.

    Science.gov (United States)

    Miaja-Avila, L; O'Neil, G C; Uhlig, J; Cromer, C L; Dowell, M L; Jimenez, R; Hoover, A S; Silverman, K L; Ullom, J N

    2015-03-01

    We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼10(6) photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >10(7) laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  12. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  13. X-ray diffraction contrast tomography (DCT) system, and an X-ray diffraction contrast tomography (DCT) method

    DEFF Research Database (Denmark)

    2012-01-01

    Source: US2012008736A An X-ray diffraction contrast tomography system (DCT) comprising a laboratory X-ray source (2), a staging device (5) rotating a polycrystalline material sample in the direct path of the X-ray beam, a first X-ray detector (6) detecting the direct X-ray beam being transmitted...

  14. Future X-ray timing missions

    CERN Document Server

    Barret, D; Staubert, R; Stella, L

    2000-01-01

    Thanks to the Rossi X-ray Timing Explorer (RXTE), it is now widely recognized that fast X-ray timing can be used to probe strong gravity fields around collapsed objects and constrain the equation of state of dense matter in neutron stars. We first discuss some of the outstanding issues which could be solved with an X-ray timing mission building on the great successes of RXTE and providing an order of magnitude better sensitivity. Then we briefly describe the 'Experiment for X-ray timing and Relativistic Astrophysics' (EXTRA) recently proposed to the European Space Agency as a follow-up to RXTE and the related US mission 'Relativistic Astrophysics Explorer' (RAE).

  15. Future X-Ray Timing Missions

    Science.gov (United States)

    Barret, Didier; van der Klis, Michiel; Skinner, Gerry K.; Staubert, Rüdiger; Stella, Luigi

    Thanks to the Rossi X-ray Timing Explorer (RXTE), it is now widely recognized that fast X-ray timing can be used to probe strong gravity fields around collapsed objects and constrain the equation of state of dense matter in neutron stars. We first discuss some of the outstanding issues which could be solved with an X-ray timing mission building on the great successes of RXTE and providing an order of magnitude better sensitivity. Then we briefly describe the `Experiment for X-ray timing and Relativistic Astrophysics' (EXTRA) recently proposed to the European Space Agency as a follow-up to RXTE and the related US mission `Relativistic Astrophysics Explorer' (RAE).

  16. Experimental x-ray ghost imaging

    CERN Document Server

    Pelliccia, Daniele; Scheel, Mario; Cantelli, Valentina; Paganin, David M

    2016-01-01

    We report an experimental proof of principle for ghost imaging in the hard x-ray energy range. We used a synchrotron x-ray beam that was split using a thin crystal in Laue diffraction geometry. With an ultra-fast imaging camera, we were able to image x-rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam was correlated with the spatially resolved intensity measured on the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x-rays may open the way to protocols to reduce radiation damage in medical imaging and in non-destructive structural characterization using Free Electron Lasers.

  17. Experimental X-Ray Ghost Imaging

    Science.gov (United States)

    Pelliccia, Daniele; Rack, Alexander; Scheel, Mario; Cantelli, Valentina; Paganin, David M.

    2016-09-01

    We report an experimental proof of principle for ghost imaging in the hard-x-ray energy range. We use a synchrotron x-ray beam that is split using a thin crystal in Laue diffraction geometry. With an ultrafast imaging camera, we are able to image x rays generated by isolated electron bunches. At this time scale, the shot noise of the synchrotron emission process is measurable as speckles, leading to speckle correlation between the two beams. The integrated transmitted intensity from a sample located in the first beam is correlated with the spatially resolved intensity measured in the second, empty, beam to retrieve the shadow of the sample. The demonstration of ghost imaging with hard x rays may open the way to protocols to reduce radiation damage in medical imaging and in nondestructive structural characterization using free electron lasers.

  18. Center for X-ray Optics (CXRO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Center for X-Ray Optics at Lawrence Berkeley National Laboratory works to further science and technology using short wavelength optical systems and techniques....

  19. Why Do I Need X-Rays?

    Science.gov (United States)

    ... information you need from the Academy of General Dentistry Wednesday, August 24, 2016 About | Contact InfoBites Quick ... Related Articles: X-Rays The Academy of General Dentistry (AGD) Sets the Record Straight on Dental X- ...

  20. X-Ray Technologist Listing In California

    Data.gov (United States)

    U.S. Department of Health & Human Services — This table represents a current listing of X-Ray Technologists who are licensed by Radiologic Health Branch (RHB) of the California Department of Public Health. RHB...

  1. X-ray source for mammography

    Science.gov (United States)

    Logan, Clinton M.

    1994-01-01

    An x-ray source utilizing anode material which shifts the output spectrum to higher energy and thereby obtains higher penetrating ability for screening mammography application, than the currently utilized anode material. The currently used anode material (molybdenum) produces an energy x-ray spectrum of 17.5/19.6 keV, which using the anode material of this invention (e.g. silver, rhodium, and tungsten) the x-ray spectrum would be in the 20-35 keV region. Thus, the anode material of this invention provides for imaging of breasts with higher than average x-ray opacity without increase of the radiation dose, and thus reduces the risk of induced breast cancer due to the radiation dose administered for mammograms.

  2. Tuberculosis, advanced - chest x-rays (image)

    Science.gov (United States)

    Tuberculosis is an infectious disease that causes inflammation, the formation of tubercules and other growths within tissue, ... death. These chest x-rays show advanced pulmonary tuberculosis. There are multiple light areas (opacities) of varying ...

  3. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Lung tissue absorbs little radiation and will appear dark on the image. Until recently, x-ray images ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  4. X-ray microtomography in biology

    CERN Document Server

    Mizutani, Ryuta

    2016-01-01

    Progress in high-resolution x-ray microtomography has provided us with a practical approach to determining three-dimensional (3D) structures of opaque samples at micrometer to submicrometer resolution. In this review, we give an introduction to hard x-ray microtomography and its application to the visualization of 3D structures of biological soft tissues. Practical aspects of sample preparation, handling, data collection, 3D reconstruction, and structure analysis are described. Furthermore, different sample contrasting methods are approached in detail. Examples of microtomographic studies are overviewed to present an outline of biological applications of x-ray microtomography. We also provide perspectives of biological microtomography as the convergence of sciences in x-ray optics, biology, and structural analysis.

  5. X-ray imaging: Status and trends

    International Nuclear Information System (INIS)

    There is a veritable renaissance occurring in x-ray imaging. X-ray imaging by radiography has been a highly developed technology in medicine and industry for many years. However, high resolution imaging has not generally been practical because sources have been relatively dim and diffuse, optical elements have been nonexistent for most applications, and detectors have been slow and of low resolution. Materials analysis needs have therefore gone unmet. Rapid progress is now taking place because we are able to exploit developments in microelectronics and related material fabrication techniques, and because of the availability of intense x-ray sources. This report describes the methods and uses of x-ray imaging along with a discussion of technology advances in these areas

  6. 5.8 X-ray Calorimeters

    Science.gov (United States)

    Porter, F. Scott

    2008-01-01

    X-ray calorimeter instruments for astrophysics have seen rapid development since they were invented in 1984. The prime instrument on all currently planned X-ray spectroscopic observatories is based on calorimeter technology. This relatively simple detection concept that senses the energy of an incident photon by measuring the temperature rise of an absorber material at very low temperatures, can form the basis of a very high performance, non-dispersive spectrometer. State-of-the-art calorimeter instruments have resolving powers of over 3000, large simultaneous band-passes, and near unit efficiency. This coupled with the intrinsic imaging capability of a pixilated x-ray calorimeter array, allows true spectral-spatial instruments to be constructed. In this chapter I briefly review the detection scheme, the state-of-the-art in X-ray calorimeter instruments and the future outlook for this technology.

  7. Silicon Wafer X-ray Mirror Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this one year research project, we propose to do the following four tasks; (1) Design the silicon wafer X-ray mirror demo unit and develop a ray-tracing code to...

  8. Silicon Wafer X-ray Mirror Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this one year research project, we propose to do the following four tasks;(1) Design the silicon wafer X-ray mirror demo unit and develop a ray-tracing code to...

  9. Dental x-ray diagnostic installation

    International Nuclear Information System (INIS)

    An exemplary embodiment comprises an exposure unit including an X-ray tube and a cassette holder rotatable about vertical axes and between which the head of the patient is disposed. A radiation detector is disposed at the cassette holder for supplying an electrical signal corresponding to the dose rate when it is struck by X-rays and being interconnected with an X-ray tube voltage controller and a dose rate regulator in such manner that the X-ray tube voltage is influenced by the output of the radiation detector to control the dose rate to a value producing an optimum film blackening. A function generator determining the speed of the exposure unit is provided in which a speed curve is stored given which the radiation dose influencing the film is approximately constant

  10. Demonstration of X-ray talbot interferometry

    CERN Document Server

    Momose, A; Kawamoto, S; Hamaishi, Y; Takai, K; Suzuki, Y

    2003-01-01

    First Talbot interferometry in the hard X-ray region was demonstrated using a pair of transmission gratings made by forming gold stripes on glass plates. By aligning the gratings on the optical axis of X-rays with a separation that caused the Talbot effect by the first grating, moire fringes were produced inclining one grating slightly against the other around the optical axis. A phase object placed in front of the first grating was detected by moire-fringe bending. Using the technique of phase-shifting interferometry, the differential phase corresponding to the phase object could also be measured. This result suggests that X-ray Talbot interferometry is a novel and simple method for phase-sensitive X-ray radiography. (author)

  11. Resonant X-Ray Scattering and Absorption

    Science.gov (United States)

    Collins, S. P.; Bombardi, A.

    This chapter outlines some of the basic ideas behind nonresonant and resonant X-ray scattering, using classical or semiclassical pictures wherever possible; specifically, we highlight symmetry arguments governing the observation of X-ray optical effects, such as X-ray magnetic circular dichroism and resonant "forbidden" diffraction. Without dwelling on the microscopic physics that underlies resonant scattering, we outline some key steps required for calculating its rotation and polarization dependence, based on Cartesian and spherical tensor frameworks. Several examples of resonant scattering, involving electronic anisotropy and magnetism, are given as illustrations. Our goal is not to develop or defend theoretical concepts in X-ray scattering, but to bring together existing ideas in a pragmatic and utilitarian manner.

  12. Nonrelativistic quantum X-ray physics

    CERN Document Server

    Hau-Riege, Stefan P

    2015-01-01

    Providing a solid theoretical background in photon-matter interaction, Nonrelativistic Quantum X-Ray Physics enables readers to understand experiments performed at XFEL-facilities and x-ray synchrotrons. As a result, after reading this book, scientists and students will be able to outline and perform calculations of some important x-ray-matter interaction processes. Key features of the contents are that the scope reaches beyond the dipole approximation when necessary and that it includes short-pulse interactions. To aid the reader in this transition, some relevant examples are discussed in detail, while non-relativistic quantum electrodynamics help readers to obtain an in-depth understanding of the formalisms and processes. The text presupposes a basic (undergraduate-level) understanding of mechanics, electrodynamics, and quantum mechanics. However, more specialized concepts in these fields are introduced and the reader is directed to appropriate references. While primarily benefiting users of x-ray light-sou...

  13. Astrophysics: Unexpected X-ray flares

    Science.gov (United States)

    Campana, Sergio

    2016-10-01

    Two sources of highly energetic flares have been discovered in archival X-ray data of 70 nearby galaxies. These flares have an undetermined origin and might represent previously unknown astrophysical phenomena. See Letter p.356

  14. X-ray crystallographic studies of metalloproteins.

    Science.gov (United States)

    Volbeda, Anne

    2014-01-01

    Many proteins require metals for their physiological function. In combination with spectroscopic characterizations, X-ray crystallography is a very powerful method to correlate the function of protein-bound metal sites with their structure. Due to their special X-ray scattering properties, specific metals may be located in metalloprotein structures and eventually used for phasing the diffracted X-rays by the method of Multi-wavelength Anomalous Dispersion (MAD). How this is done is the principle subject of this chapter. Attention is also given to the crystallographic characterization of different oxidation states of redox active metals and to the complication of structural changes that may be induced by X-ray irradiation of protein crystals.

  15. Demonstration of X-ray talbot interferometry

    International Nuclear Information System (INIS)

    First Talbot interferometry in the hard X-ray region was demonstrated using a pair of transmission gratings made by forming gold stripes on glass plates. By aligning the gratings on the optical axis of X-rays with a separation that caused the Talbot effect by the first grating, moire fringes were produced inclining one grating slightly against the other around the optical axis. A phase object placed in front of the first grating was detected by moire-fringe bending. Using the technique of phase-shifting interferometry, the differential phase corresponding to the phase object could also be measured. This result suggests that X-ray Talbot interferometry is a novel and simple method for phase-sensitive X-ray radiography. (author)

  16. X-ray Emission from Solar Flares

    Indian Academy of Sciences (India)

    Rajmal Jain; Malini Aggarwal; Raghunandan Sharma

    2008-03-01

    Solar X-ray Spectrometer (SOXS), the first space-borne solar astronomy experiment of India was designed to improve our current understanding of X-ray emission from the Sun in general and solar flares in particular. SOXS mission is composed of two solid state detectors, viz., Si and CZT semiconductors capable of observing the full disk Sun in X-ray energy range of 4–56 keV. The X-ray spectra of solar flares obtained by the Si detector in the 4–25 keV range show evidence of Fe and Fe/Ni line emission and multi-thermal plasma. The evolution of the break energy point that separates the thermal and non-thermal processes reveals increase with increasing flare plasma temperature. Small scale flare activities observed by both the detectors are found to be suitable to heat the active region corona; however their location appears to be in the transition region.

  17. Inelastic magnetic X-ray scattering

    Science.gov (United States)

    Platzman, P. M.; Tzoar, N.

    1985-04-01

    The theory of magnetic X-ray scattering is used to discuss the possibilities for employing inelastic scattering to probe the magnetic properties of condensed matter systems. In particular, it is shown how the interference between the nonmagnetic (Compton) and magnetic scattering arising from the use of circularly polarized X-rays is absolutely essential in such experiments. The very beautiful preliminary experiments by Sakai and Ono (1976) on Fe which use circularly polarized Moessbauer gamma-rays will be discussed. They already show the sensitivity of the technique to the 'magnetic form factor'. In addition, the physics of a unique quarter wave plate employed in obtaining circularly polarized X-rays is considered, and the implications of this advance for doing such experiments on existing synchrotron X-ray sources are discussed.

  18. Capillary Optics generate stronger X-rays

    Science.gov (United States)

    1996-01-01

    NASA scientist, in the Space Sciences lab at Marshall, works with capillary optics that generate more intense X-rays than conventional sources. This capability is useful in studying the structure of important proteins.

  19. Insights from soft X-rays

    DEFF Research Database (Denmark)

    Raaf, Jennifer; Issinger, Olaf-Georg; Niefind, Karsten

    2008-01-01

    The diffraction pattern of a protein crystal is normally a product of the interference of electromagnetic waves scattered by electrons of the crystalline sample. The diffraction pattern undergoes systematic changes in case additionally X-ray absorption occurs, meaning if the wavelength of the pri......The diffraction pattern of a protein crystal is normally a product of the interference of electromagnetic waves scattered by electrons of the crystalline sample. The diffraction pattern undergoes systematic changes in case additionally X-ray absorption occurs, meaning if the wavelength...... of the primary X-ray beam is relatively close to the absorption edge of selected elements of the sample. The resulting effects are summarized as "anomalous dispersion" and can be always observed with "soft" X-rays (wavelength around 2 A) since they match the absorption edges of sulfur and chlorine...

  20. Dentistry 4. X-ray diagnostics

    International Nuclear Information System (INIS)

    DIN pocketbook 267/4 gives an overview of the normative requirements of the new X-Ray and Radiation Protection Ordinance, which has been in effect since 1 November 2011. This DIN pocketbook is intended for anyone charged with professional responsibility for the use of ionizing radiation in dentistry, operators and users of x-ray devices, radiation protection officers, accredited experts, manufacturers as well as for anyone with an interest in radiation protection or optimal radiological diagnostics. It contains standards relating to the following areas: acceptance and constancy testing; devices for evaluating findings (monitors, film viewing devices), films, printers; archiving, designating, labelling. Adherence to the standards makes it possible to avoid distractive artefacts in x-ray images and optimise the quality of x-ray diagnostics in dentistry.

  1. Linking Jet Emission, X-Ray States, and Hard X-Ray Tails in the Neutron Star X-Ray Binary GX 17+2

    NARCIS (Netherlands)

    S. Migliari; J.C.A. Miller-Jones; R.P. Fender; J. Homan; T. di Salvo; R.E. Rothschild; M.P. Rupen; J.A. Tomsick; R. Wijnands; M. van der Klis

    2007-01-01

    We present the results of simultaneous radio (VLA) and X-ray (RXTE) observations of the Z-type neutron star X-ray binary GX 17+2. The aim is to assess the coupling between X-ray and radio properties throughout its three rapidly variable X-ray states and during the time-resolved transitions. These ob

  2. Advanced detectors for X-ray microscopy

    International Nuclear Information System (INIS)

    Over the last decade the advances in x-ray microscopy have mainly been due to the development of x-ray source technology and to the micro-fabrication of x-ray optics. These advances have spurred the development of x-ray microscopes that are approaching the best resolution possible in the presence of radiation damage in the specimen. In addition, the development of specimen preparation techniques that reduce tile effects of radiation damage on the specimen are underway. In contrast, tile development or x-ray detectors for x-ray microscopy has been a low priority. The objective of the work was to develop a new detector for x-ray microscopy. This involved the modification of a Thorn EMI electron tube in order to sensitise the multiplier for soil x-rays In the energy range of interest (0.2-6 keV). The electron multiplier was then tested on a repetitive laser plasma source, which has been shown to be eminently suitable for a laboratory scale x-ray microscope, and the Scanning Transmission X-ray Microscope (STXM) at the National Synchrotron Light Source (NSLS), which is the most successful STXM presently in operation. The processed data from tile electron multiplier was used to characterise its response and assess its potential as all alternative to existing detectors. In addition, ID21, the microscopy beamline at the European Synchrotron Radiation Source (ESRF) was studied to assess the need for a beam position monitor close to the exit slit of the monochromator. This involved the ray tracing of the beamline. It was proposed that in the case of a crystal monochromator a beam position monitor based oil the total signal from a photo-emitting blade containing a number of different diameter pinholes was sufficient. However, for a grating monochromator tile beamline design relied upon feedback from a beam position monitor capable of detecting the height of the beam at tile entrance to the microscope. A number of conceptual designs for a monitor that could fulfil this

  3. Principles of X-ray Navigation

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, John Eric; /SLAC

    2006-03-17

    X-ray navigation is a new concept in satellite navigation in which orientation, position and time are measured by observing stellar emissions in x-ray wavelengths. X-ray navigation offers the opportunity for a single instrument to be used to measure these parameters autonomously. Furthermore, this concept is not limited to missions in close proximity to the earth. X-ray navigation can be used on a variety of missions from satellites in low earth orbit to spacecraft on interplanetary missions. In 1997 the Unconventional Stellar Aspect Experiment (USA) will be launched as part of the Advanced Research and Global Observation Satellite (ARGOS). USA will provide the first platform for real-time experimentation in the field of x-ray navigation and also serves as an excellent case study for the design and manufacturing of space qualified systems in small, autonomous groups. Current techniques for determining the orientation of a satellite rely on observations of the earth, sun and stars in infrared, visible or ultraviolet wavelengths. It is possible to use x-ray imaging devices to provide arcsecond level measurement of attitude based on star patterns in the x-ray sky. This technique is explored with a simple simulation. Collimated x-ray detectors can be used on spinning satellites to provide a cheap and reliable measure of orientation. This is demonstrated using observations of the Crab Pulsar taken by the high Energy Astronomy Observatory (HEAO-1) in 1977. A single instrument concept is shown to be effective, but dependent on an a priori estimate of the guide star intensity and thus susceptible to errors in that estimate. A star scanner based on a differential measurement from two x-ray detectors eliminates the need for an a priori estimate of the guide star intensity. A first order model and a second order model of the two star scanner concepts are considered. Many of the stars that emit in the x-ray regime are also x-ray pulsars with frequency stability approaching a

  4. X-ray scattering from dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    McSherry, D.J

    2000-09-01

    Dense plasmas were studied by probing them with kilovolt x-rays and measuring those scattered at various angles. The Laser-Produced x-ray source emitted Ti He alpha 4.75 keV x-rays. Two different plasma types were explored. The first was created by laser driven shocks on either side of a sample foil consisting of 2 micron Al layer, sandwiched between two 1 micron CH layers. We have observed a peak in the x-ray scattering cross section, indicating diffraction from the plasma. However, the experimentally inferred plasma density, broadly speaking, did not always agree with the hydrodynamic simulation MEDX (A modified version of MEDUSA). The second plasma type that we studied was created by soft x-ray heating on either side of a sample foil, this time consisting of 1 micron layer of Al, sandwiched between two 0.2 micron CH layers. Two foil targets, each consisting of a 0.1 micron thick Au foil mounted on 1 micron of CH, where placed 4 mm from the sample foil. The soft x-rays where produced by laser irradiating these two foil targets. We found that, 0.5 ns after the peak of the laser heating pulses, the measured cross sections more closely matched those simulated using the Thomas Fermi model than the Inferno model. Later in time, at 2 ns, the plasma is approaching a weakly coupled state. This is the first time x-ray scattering cross sections have been measured from dense plasmas generated by radiatively heating both sides of the sample. Moreover, these are absolute values typically within a factor of two of expectation for early x-ray probe times. (author)

  5. X-ray laser program at MBI

    Science.gov (United States)

    Nickles, P. V.; Janulewicz, K. A.; Lucianetti, A.; Priebe, G.; Zigler, A.; Rocca, J. J.; Sandner, W.

    2002-11-01

    A survey of the Max Born Institute (MBI) activities in the field of X-ray lasers (XRLs) is presented. The main interest is focused on the transient soft X-ray lasers. Additionally, much work is put to look for new, efficient, compact (table-top) pumping schemes with a prospect to be applied in practice. The current state of the research and the plans for the future are described as well.

  6. Capacitor discharges, magnetohydrodynamics, X-rays, ultrasonics

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology, Volume 1: Capacitor Discharges - Magnetohydrodynamics - X-Rays - Ultrasonics deals with the theoretical and engineering problems that arise in the capacitor discharge technique.This book discusses the characteristics of dielectric material, symmetrical switch tubes with mercury filling, and compensation conductor forms. The transformed discharge for highest current peaks, ignition transformer for internal combustion engines, and X-ray irradiation of subjects in mechanical motion are also elaborated. This text likewise covers the transformed capacitor discharge in w

  7. Supernova remnants: the X-ray perspective

    OpenAIRE

    Vink, Jacco

    2011-01-01

    Supernova remnants are beautiful astronomical objects that are also of high scientific interest, because they provide insights into supernova explosion mechanisms, and because they are the likely sources of Galactic cosmic rays. X-ray observations are an important means to study these objects.And in particular the advances made in X-ray imaging spectroscopy over the last two decades has greatly increased our knowledge about supernova remnants. It has made it possible to map the products of fr...

  8. Scattered X-ray beam nondestructive testing

    Science.gov (United States)

    Harding, G.; Kosanetzky, J.

    1989-08-01

    X-ray scatter interactions generally dominate the linear attenuation coefficient at the photon energies typical of medical and industrial radiography. Specific advantages of X-ray scatter imaging, including a flexible choice of measurement geometry, direct 3D-imaging capability (tomography) and improved information for material characterization, are illustrated with results from Compton and coherent scatter devices. Applications of a Compton backscatter scanner (ComScan) in the aerospace industry and coherent scatter imaging in security screening are briefly considered.

  9. Globular cluster x-ray sources.

    Science.gov (United States)

    Pooley, David

    2010-04-20

    Globular clusters and x-ray astronomy have a long and fruitful history. Uhuru and OSO-7 revealed highly luminous (> 10(36) ergs(-1)) x-ray sources in globular clusters, and Einstein and ROSAT revealed a larger population of low-luminosity (luminosity sources were low-mass x-ray binaries in outburst and that they were orders of magnitude more abundant per unit mass in globular clusters than in the rest of the galaxy. However, the low-luminosity sources proved difficult to classify. Many ideas were put forth--low-mass x-ray binaries in quiescence (qLMXBs), cataclysmic variables (CVs), active main-sequence binaries (ABs), and millisecond pulsars (MSPs)--but secure identifications were scarce. In ROSAT observations of 55 clusters, about 25 low-luminosity sources were found. Chandra has now observed over 80 Galactic globular clusters, and these observations have revealed over 1,500 x-ray sources. The superb angular resolution has allowed for many counterpart identifications, providing clues to the nature of this population. It is a heterogeneous mix of qLMXBs, CVs, ABs, and MSPs, and it has been shown that the qLMXBs and CVs are both, in part, overabundant like the luminous LMXBs. The number of x-ray sources in a cluster correlates very well with its encounter frequency. This points to dynamical formation scenarios for the x-ray sources and shows them to be excellent tracers of the complicated internal dynamics. The relation between the encounter frequency and the number of x-ray sources has been used to suggest that we have misunderstood the dynamical states of globular clusters.

  10. Globular cluster x-ray sources

    Science.gov (United States)

    Pooley, David

    2010-01-01

    Globular clusters and x-ray astronomy have a long and fruitful history. Uhuru and OSO-7 revealed highly luminous (> 1036 ergs-1) x-ray sources in globular clusters, and Einstein and ROSAT revealed a larger population of low-luminosity (luminosity sources were low-mass x-ray binaries in outburst and that they were orders of magnitude more abundant per unit mass in globular clusters than in the rest of the galaxy. However, the low-luminosity sources proved difficult to classify. Many ideas were put forth—low-mass x-ray binaries in quiescence (qLMXBs), cataclysmic variables (CVs), active main-sequence binaries (ABs), and millisecond pulsars (MSPs)—but secure identifications were scarce. In ROSAT observations of 55 clusters, about 25 low-luminosity sources were found. Chandra has now observed over 80 Galactic globular clusters, and these observations have revealed over 1,500 x-ray sources. The superb angular resolution has allowed for many counterpart identifications, providing clues to the nature of this population. It is a heterogeneous mix of qLMXBs, CVs, ABs, and MSPs, and it has been shown that the qLMXBs and CVs are both, in part, overabundant like the luminous LMXBs. The number of x-ray sources in a cluster correlates very well with its encounter frequency. This points to dynamical formation scenarios for the x-ray sources and shows them to be excellent tracers of the complicated internal dynamics. The relation between the encounter frequency and the number of x-ray sources has been used to suggest that we have misunderstood the dynamical states of globular clusters. PMID:20404204

  11. Parametric X-rays at FAST

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Tanaji [Fermilab

    2016-06-01

    We discuss the generation of parametric X-rays (PXR) in the photoinjector at the new FAST facility at Fermilab. Detailed calculations of the intensity spectrum, energy and angular widths and spectral brilliance with a diamond crystal are presented. We also report on expected results with PXR generated while the beam is channeling. The low emittance electron beam makes this facility a promising source for creating brilliant X-rays.

  12. Detection limits in x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    X-ray fluorescence spectrometry is a well established analytical technique for elemental analysis of solids, powders, or liquids. This extended abstract briefly discusses the detection limits or sensitivity of x-ray spectrometers in x-ray fluorescence analysis

  13. Optics Developments for X-Ray Astronomy

    Science.gov (United States)

    Ramsey, Brian

    2014-01-01

    X-ray optics has revolutionized x-ray astronomy. The degree of background suppression that these afford, have led to a tremendous increase in sensitivity. The current Chandra observatory has the same collecting area (approx. 10(exp 3)sq cm) as the non-imaging UHURU observatory, the first x-ray observatory which launched in 1970, but has 5 orders of magnitude more sensitivity due to its focusing optics. In addition, its 0.5 arcsec angular resolution has revealed a wealth of structure in many cosmic x-ray sources. The Chandra observatory achieved its resolution by using relatively thick pieces of Zerodur glass, which were meticulously figured and polished to form the four-shell nested array. The resulting optical assembly weighed around 1600 kg, and cost approximately $0.5B. The challenge for future x-ray astronomy missions is to greatly increase the collecting area (by one or more orders of magnitude) while maintaining high angular resolution, and all within realistic mass and budget constraints. A review of the current status of US optics for x-ray astronomy will be provided along with the challenges for future developments.

  14. Coherence in X-ray physics.

    Science.gov (United States)

    Lengeler, B

    2001-06-01

    Highly brilliant synchrotron radiation sources have opened up the possibility of using coherent X-rays in spectroscopy and imaging. Coherent X-rays are characterized by a large lateral coherence length. Speckle spectroscopy is extended to hard X-rays, improving the resolution to the nm range. It has become possible to image opaque objects in phase contrast with a sensitivity far superior to imaging in absorption contrast. All the currently available X-ray sources are chaotic sources. Their characterization in terms of coherence functions of the first and second order is introduced. The concept of coherence volume, defined in quantum optics terms, is generalized for scattering experiments. When the illuminated sample volume is smaller than the coherence volume, the individuality of the defect arrangement in a sample shows up as speckle in the scattered intensity. Otherwise, a configurational average washes out the speckle and only diffuse scattering and possibly Bragg reflections will survive. The loss of interference due to the finite detection time, to the finite detector pixel size and to uncontrolled degrees of freedom in the sample is discussed at length. A comparison between X-ray scattering, neutron scattering and mesoscopic electron transport is given. A few examples illustrate the possibilities of coherent X-rays for imaging and intensity correlation spectroscopy.

  15. Elliptical X-Ray Spot Measurement

    CERN Document Server

    Richardson, R A; Weir, J T; Richardson, Roger A.; Sampayan, Stephen; Weir, John T.

    2000-01-01

    The so-called roll bar measurement uses a heavy metal material, optically thick to x-rays, to form a shadow of the x-ray origination spot. This spot is where an energetic electron beam interacts with a high Z target. The material (the "roll bar") is slightly curved to avoid alignment problems. The roll bar is constructed and positioned so that the x-rays are shadowed in the horizontal and vertical directions, so information is obtained in two dimensions. If a beam profile is assumed (or measured by other means), the equivalent x-ray spot size can be calculated from the x-ray shadow cast by the roll bar. Thus the ellipticity of the beam can be calculated, assuming the ellipse of the x-ray spot is aligned with the roll bar. The data is recorded using a scintillator and gated camera. Data will be presented from measurements using the ETA II induction LINAC. The accuracy of the measurement is checked using small elliptical targets.

  16. Echoes in X-ray Binaries

    CERN Document Server

    O'Brien, K; Hynes, R; Chen, W; Haswell, C; Still, M

    2002-01-01

    We present a method of analysing the correlated X-ray and optical/UV variability in X-ray binaries, using the observed time delays between the X-ray driving lightcurves and their reprocessed optical echoes. This allows us to determine the distribution of reprocessing sites within the binary. We model the time-delay transfer functions by simulating the distribution of reprocessing regions, using geometrical and binary parameters. We construct best-fit time-delay transfer functions, showing the regions in the binary responsible for the reprocessing of X-rays. We have applied this model to observations of the Soft X-ray Transient, GRO j1655-40. We find the optical variability lags the X-ray variability with a mean time delay of 19.3$pm{2.2}$ seconds. This means that the outer regions of the accretion disc are the dominant reprocessing site in this system. On fitting the data to a simple geometric model, we derive a best-fit disk half-opening angle of 13.5$^{+2.1}_{-2.8}$ degrees, which is similar to that observe...

  17. A million X-ray detections

    Science.gov (United States)

    Webb, N.; XMM-Newton Survey Science Centre (SSC)

    2016-06-01

    Part of the XMM-Newton Survey Science Centre responsibilities include producing an X-ray catalogue of all X-ray sources detected with XMM-Newton. The latest version, 3XMM, takes advantage of improvements made to the source characterisation, reducing the number of spurious detections, but providing better astrometric precision, greater net sensitivity, as well as spectra and timeseries for a quarter of all catalogue detections. The data release 5 (3XMM-DR5, April 2015) is derived from the first 13 years of observations with XMM-Newton. 3XMM-DR5 includes 565962 X-ray detections and 396910 unique sources, detected as many as 48 times. 3XMM-DR5 is therefore the largest X-ray source catalogue. 3XMM-DR6 will be made available during 2016 and will augment the catalogue with 70000 X-ray detections. Over the next decade the catalogue will reach 1 million X-ray detections, including galaxy clusters, galaxies, tidal disruption events, gamma-ray bursts, stars, stellar mass compact objects, supernovae, planets, comets and many other systems. Thanks to the wide range of data products for each catalogue detection, the catalogue is an excellent resource for finding populations of sources as well as new and extreme objects. Here we present results achieved from searching the catalogue and discuss improvements that will be provided in future versions.

  18. X-ray Emission of Hollow Atoms

    Institute of Scientific and Technical Information of China (English)

    ZhaoYongtao; XiaoGuoqing; ZhangXiaoan; YangZhihu; ChenXimeng; ZhangYanping

    2003-01-01

    We have systematically investigated the X-rays emission of hollow atoms (HA) which formed in the interaction of highly charged ions with a variety of solid surfaces at the atomic physics experimental setup of IMP. The X-ray spectra were measured by Si(Li) detectors with effective energy ranging from 1 keV to 60 keV. The results show that, the X-ray emission from the formed HA is closely correlated with the charge state of the projectile ions, and weakly correlated with the velocity of the projectile ions. For example, it was found that when Ar18+ ions interact with Be-target, the yield of K X-ray with character energy of 3.0 keV is 7.2×10-3 per ion, which is two times and 5 order of magnitude higher than those in the interactions of Ar17+ and Ar16+ ions respectively. When Ar15+ ions interact with the same targets, the Argon K X-ray would be too feeble to be detected. The X-ray yield with single ion in this experiment can be represented by the following equation,

  19. Low exposure x-ray transmission measurements for contrast media detection with filtered x-rays

    International Nuclear Information System (INIS)

    A feasibility study of X-ray transmission measurements for contrast media with less exposure using filtered X-rays and their energy information is described. Based on measurements of the energy spectra of La-filtered X-rays, sensitivity to the contrast media and the relative quantity of dose exposure of filtered X-rays as the ratio to white X-rays are shown. The dose exposure for the measurement of iodine contrast media is reduced by more than 50% with a 400 μm thick La filter. By using a filter with atomic number close to that of iodine such as Cs and Ba, a greater reduction in dose exposure with a smaller increase in the current of the X-ray tube is expected. (author)

  20. Effects of x-ray does on rhizosphere studies using x-ray computed tomography

    OpenAIRE

    Susan Zappala; Jonathan R Helliwell; Tracy, Saoirse R.; Stefan Mairhofer; Sturrock, Craig J.; Tony Pridmore; Malcolm Bennett; Sacha J. Mooney

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such ...

  1. Simulation of transmitted X-rays in a polycapillary X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Shiqi [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Liu, Zhiguo, E-mail: liuzhiguo512@126.com [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi; Wang, Kai; Yi, Longtao; Yang, Kui; Chen, Man; Wang, Jinbang [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-09-21

    The geometrical description of capillary systems adjusted for the controlled guiding of X-rays and the basic theory of the transmission of X-rays are presented. A method of numerical calculation, based on Ray-Tracing theory, is developed to simulate the transmission efficiency of an X-ray parallel lens and the shape and size of the light spot gain from it. The simulation results for two half-lenses are in good agreement with the experimental results.

  2. Simulation of transmitted X-rays in a polycapillary X-ray lens

    International Nuclear Information System (INIS)

    The geometrical description of capillary systems adjusted for the controlled guiding of X-rays and the basic theory of the transmission of X-rays are presented. A method of numerical calculation, based on Ray-Tracing theory, is developed to simulate the transmission efficiency of an X-ray parallel lens and the shape and size of the light spot gain from it. The simulation results for two half-lenses are in good agreement with the experimental results

  3. Comparison of x-ray output of inverter-type x-ray equipment

    International Nuclear Information System (INIS)

    The x-ray output of 54 inverter-type x-ray apparatuses used at 18 institutions was investigated. The reproducibility and linearity of x-ray output and variations among the x-ray equipment were evaluated using the same fluorescence meter. In addition, the x-ray apparatuses were re-measured using the same non-invasive instrument to check for variations in tube voltage, tube current, and irradiation time. The non-invasive instrument was calibrated by simultaneously obtaining measurements with an invasive instrument, employing the tube voltage and current used for the invasive instrument, and the difference was calculated. Reproducibility of x-ray output was satisfactory for all x-ray apparatuses. The coefficient of variation was 0.04 or less for irradiation times of 5 ms or longer. In 84.3% of all x-ray equipment, variation in the linearity of x-ray output was 15% or less for an irradiation time of 5 ms. However, for all the apparatuses, the figure was 50% when irradiation time was the shortest (1 to 3 ms). Variation in x-ray output increased as irradiation time decreased. Variation in x-ray output ranged between 1.8 and 2.5 compared with the maximum and minimum values, excluding those obtained at the shortest irradiation time. The relative standard deviation ranged from ±15.5% to ±21.0%. The largest variation in x-ray output was confirmed in regions irradiated for the shortest time, with smaller variations observed for longer irradiation times. The major factor responsible for variation in x-ray output in regions irradiated for 10 ms or longer, which is a relatively long irradiation time, was variation in tube current. Variation in tube current was slightly greater than 30% at maximum, with an average value of 7% compared with the preset tube current. Variations in x-ray output in regions irradiated for the shortest time were due to photographic effects related to the rise and fall times of the tube voltage waveform. Accordingly, in order to obtain constant x-ray

  4. Laser-based X-ray and electron source for X-ray fluorescence studies

    Science.gov (United States)

    Valle Brozas, F.; Crego, A.; Roso, L.; Peralta Conde, A.

    2016-08-01

    In this work, we present a modification to conventional X-rays fluorescence using electrons as excitation source and compare it with the traditional X-ray excitation for the study of pigments. For this purpose, we have constructed a laser-based source capable to produce X-rays as well as electrons. Because of the large penetration depth of X-rays, the collected fluorescence signal is a combination of several material layers of the artwork under study. However, electrons are stopped in the first layers, allowing a more superficial analysis. We show that the combination of both excitation sources can provide extremely valuable information about the structure of the artwork.

  5. Fabrication of large area X-ray diffraction grating for X-ray phase imaging

    International Nuclear Information System (INIS)

    X-ray lithography, which uses highly directional synchrotron radiation, is one of the technologies that can be used for fabricating micrometer-sized structures. In X-ray lithography, the accuracy of the fabricated structure depends largely on the accuracy of the X-ray mask. Since X-ray radiation is highly directional, a micro-fabrication technology that produces un-tapered and high aspect ratio highly absorbent structures on a low absorbent membrane is required. Conventionally, a resin material is used as the support membrane for large area X-ray masks. However, resin membranes have the disadvantage that they can sag after several cycles of X-ray exposure due to the heat generated by the X-rays. Therefore, we proposed and used thin carbon wafers for the membrane material because carbon has an extremely small thermal expansion coefficient. We fabricated new carbon membrane X-ray masks, and these results of X-ray lithography demonstrate the superior performance.

  6. X-ray-induced photo-chemistry and X-ray absorption spectroscopy of biological samples

    OpenAIRE

    George, Graham N.; Pickering, Ingrid J.; Pushie, M. Jake; Nienaber, Kurt; Hackett, Mark J.; Ascone, Isabella; Hedman, Britt; Hodgson, Keith O.; Aitken, Jade B.; Levina, Aviva; Glover, Christopher; Lay, Peter A.

    2012-01-01

    X-ray-induced photo-chemistry of metal sites within biological molecules is a concern for X-ray absorption spectroscopy, X-ray crystallography and other techniques in which samples are illuminated with X-rays. The effects of X-ray-induced photo-chemistry are reviewed and the methods used to mitigate these in X-ray absorption spectroscopy are outlined.

  7. Low energy x-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.R.

    1981-06-05

    A subkilovolt spectrometer has been produced to permit high-energy-resolution, time-dependent x-ray intensity measurements. The diffracting element is a curved mica (d = 9.95A) crystal. To preclude higher order (n > 1) diffractions, a carbon x-ray mirror that reflects only photons with energies less than approx. 1.1 keV is utilized ahead of the diffracting element. The nominal energy range of interest is 800 to 900 eV. The diffracted photons are detected by a gold-surface photoelectric diode designed to have a very good frequency response, and whose current is recorded on an oscilloscope. A thin, aluminium light barrier is placed between the diffracting crystal and the photoelectric diode detector to keep any uv generated on or scattered by the crystal from illuminating the detector. High spectral energy resolution is provided by many photocathodes between 8- and 50-eV wide placed serially along the diffracted x-ray beam at the detector position. The spectrometer was calibrated for energy and energy dispersion using the Ni L..cap alpha../sub 1/ /sub 2/ lines produced in the LLNL IONAC accelerator and in third order using a molybdenum target x-ray tube. For the latter calibration the carbon mirror was replaced by one surfaced with rhodium to raise the cut-off energy to about 3 keV. The carbon mirror reflection dependence on energy was measured using one of our Henke x-ray sources. The curved mica crystal diffraction efficiency was measured on our Low-Energy x-ray (LEX) machine. The spectrometer performs well although some changes in the way the x-ray mirror is held are desirable. 16 figures.

  8. New achievements in X-ray optics——the X-ray lens and its applications

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    An X-ray lens consists of a large number of X-ray capillaries. It can collect divergent X-rays emitted from an X-ray source and form a focused or parallel beam of high intensity. So it is an effective tool for adjusting and controlling wide bandwidth X-ray beams. In this paper, the X-ray lens made by the X-ray Optics Laboratory of Institute of Low Energy Nuclear Physics at Beijing Normal University and its applications in the field of X-ray analysis are presented.

  9. X-Ray Calorimeter Arrays for Astrophysics

    Science.gov (United States)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  10. X-ray spectroscopy an introduction

    CERN Document Server

    Agarwal, Bipin K

    1979-01-01

    Rontgen's discovery of X-rays in 1895 launched a subject which became central to the development of modern physics. The verification of many of the predic­ tions of quantum theory by X-ray spectroscopy in the early part of the twen­ tieth century stimulated great interest in thi's area, which has subsequently influenced fields as diverse as chemical physics, nuclear physics, and the study of the electronic properties of solids, and led to the development of techniques such as Auger, Raman, and X-ray photoelectron spectroscopy. The improvement of the theoretical understanding of the physics underlying X-ray spectroscopy has been accompanied by advances in experimental techniques, and the subject provides an instructive example of how progress on both these fronts can be mutually beneficial. This book strikes a balance between his­ torical description, which illustrates this symbiosis, and the discussion of new developments. The application of X-ray spectroscopic methods to the in­ vestigation of chemical b...

  11. Advanced X-ray diffractive optics

    Energy Technology Data Exchange (ETDEWEB)

    Vila-Comamala, J; Jefimovs, K; Sarkar, S S; Solak, H H; Guzenko, V A; Stampanoni, M; Marone, F; Raabe, J; Tzvetkov, G; Grolimund, D; Borca, C N; David, C [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Pilvi, T; Ritala, M [Department of Chemistry, FIN-00014 University of Helsinki (Finland); Fink, R H [Friedrich-Alexander Universitaet, D-91058 Erlangen (Germany); Kaulich, B, E-mail: joan.vila@psi.c [ELETTRA Sincrotrone, I-34012 Basovizza (Italy)

    2009-09-01

    X-ray microscopy greatly benefits from the advances in x-ray optics. At the Paul Scherrer Institut, developments in x-ray diffractive optics include the manufacture and optimization of Fresnel zone plates (FZPs) and diffractive optical elements for both soft and hard x-ray regimes. In particular, we demonstrate here a novel method for the production of ultra-high resolution FZPs. This technique is based on the deposition of a zone plate material (iridium) onto the sidewalls of a prepatterned template structure (silicon) by atomic layer deposition. This approach overcomes the limitations due to electron-beam writing of dense patterns in FZP fabrication and provides a clear route to push the resolution into sub-10 nm regime. A FZP fabricated by this method was used to resolve test structures with 12 nm lines and spaces at the scanning transmission x-ray microscope of the PolLux beamline of the Swiss Light Source at 1.2 keV photon energy.

  12. Polarisation modulation in X-ray binaries

    Science.gov (United States)

    Ingram, Adam; Maccarone, Thomas

    2016-07-01

    X-ray polarimetry promises to provide a powerful new lever arm for studying accretion onto black holes with the next generation of X-ray telescopes. I will discuss how polarisation can be used to help constrain the physical origin of quasi-periodic oscillations (QPOs) observed in the X-ray light curves of accreting black holes. QPOs may be signatures of the frame dragging effect: in General Relativity, a spinning black hole twists up the surrounding space-time, causing vertical precession of nearby orbits. In the truncated disc / precessing inner flow model, the entire inner accretion flow precesses as a solid body causing a modulation in the X-ray flux through solid angle and Doppler effects. This model also predicts the observed polarisation of the X-ray signal to vary quasi-periodically. I will summarise our work to model the polarisation signal from a precessing accretion flow, starting with simple assumptions about the emission mechanism but taking General Relativity fully into account. We find that it should be possible to measure the predicted modulation in polarisation degree for a reasonable region of parameter space with a polarimeter capable of detecting ~60 counts per second from a bright black hole binary. I will also show that sensitivity can be greatly improved by correlating the signal with a high count rate reference band signal.

  13. Optics for coherent X-ray applications.

    Science.gov (United States)

    Yabashi, Makina; Tono, Kensuke; Mimura, Hidekazu; Matsuyama, Satoshi; Yamauchi, Kazuto; Tanaka, Takashi; Tanaka, Hitoshi; Tamasaku, Kenji; Ohashi, Haruhiko; Goto, Shunji; Ishikawa, Tetsuya

    2014-09-01

    Developments of X-ray optics for full utilization of diffraction-limited storage rings (DLSRs) are presented. The expected performance of DLSRs is introduced using the design parameters of SPring-8 II. To develop optical elements applicable to manipulation of coherent X-rays, advanced technologies on precise processing and metrology were invented. With propagation-based coherent X-rays at the 1 km beamline of SPring-8, a beryllium window fabricated with the physical-vapour-deposition method was found to have ideal speckle-free properties. The elastic emission machining method was utilized for developing reflective mirrors without distortion of the wavefronts. The method was further applied to production of diffraction-limited focusing mirrors generating the smallest spot size in the sub-10 nm regime. To enable production of ultra-intense nanobeams at DLSRs, a low-vibration cooling system for a high-heat-load monochromator and advanced diagnostic systems to characterize X-ray beam properties precisely were developed. Finally, new experimental schemes for combinative nano-analysis and spectroscopy realised with novel X-ray optics are discussed. PMID:25177986

  14. Nonlinear X-ray Compton Scattering

    CERN Document Server

    Fuchs, Matthias; Chen, Jian; Ghimire, Shambhu; Shwartz, Sharon; Kozina, Michael; Jiang, Mason; Henighan, Thomas; Bray, Crystal; Ndabashimiye, Georges; Bucksbaum, P H; Feng, Yiping; Herrmann, Sven; Carini, Gabriella; Pines, Jack; Hart, Philip; Kenney, Christopher; Guillet, Serge; Boutet, Sebastien; Williams, Garth; Messerschmidt, Marc; Seibert, Marvin; Moeller, Stefan; Hastings, Jerome B; Reis, David A

    2015-01-01

    X-ray scattering is a weak linear probe of matter. It is primarily sensitive to the position of electrons and their momentum distribution. Elastic X-ray scattering forms the basis of atomic structural determination while inelastic Compton scattering is often used as a spectroscopic probe of both single-particle excitations and collective modes. X-ray free-electron lasers (XFELs) are unique tools for studying matter on its natural time and length scales due to their bright and coherent ultrashort pulses. However, in the focus of an XFEL the assumption of a weak linear probe breaks down, and nonlinear light-matter interactions can become ubiquitous. The field can be sufficiently high that even non-resonant multiphoton interactions at hard X-rays wavelengths become relevant. Here we report the observation of one of the most fundamental nonlinear X-ray-matter interactions, the simultaneous Compton scattering of two identical photons producing a single photon at nearly twice the photon energy. We measure scattered...

  15. X-ray absorption spectroscopy of metalloproteins.

    Science.gov (United States)

    Ward, Jesse; Ollmann, Emily; Maxey, Evan; Finney, Lydia A

    2014-01-01

    Metalloproteins are enormously important in biology. While a variety of techniques exist for studying metals in biology, X-ray absorption spectroscopy is particularly useful in that it can determine the local electronic and physical structure around the metal center, and is one of the few avenues for studying "spectroscopically silent" metal ions like Zn(II) and Cu(I) that have completely filled valence bands. While X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) are useful for studying metalloprotein structure, they suffer the limitation that the detected signal is an average of all the various metal centers in the sample, which limits its usefulness for studying metal centers in situ or in cell lysates. It would be desirable to be able to separate the various proteins in a mixture prior to performing X-ray absorption studies, so that the derived signal is from one species only. Here we describe a method for performing X-ray absorption spectroscopy on protein bands following electrophoretic separation and western blotting.

  16. X-ray spectra for mamography

    International Nuclear Information System (INIS)

    By means of Monte Carlo methods the X-ray spectra that produce Mammography equipment have been obtained. The mammographs are widely used with the purpose of diagnosing the cancer of the mammary glands. Different makers and mammographs models are distinguished by the voltage capacity and the current, exist as well as in the target type and filter. The targets that are used are Mo, Rh and W and the filters are Mo, Rh, Al and Be. In this work the results obtained by means of the MCNP code of the X-ray spectra take place when an electron beam of 28 keV is made impact on Mo, Rh and W targets, as well as the spectra that result of filtering these X rays using different types of filters. The resulting spectra contain the continuous spectrum of the stopping radiation, as well as the X rays characteristic of the used target. The utility of estimating the spectra of X rays by means of Monte Carlo is that it can use to estimate the absorbed dose by the gland, as well as the absorbed dose by other organs. It also allows to calculate the detector response. (Author)

  17. Supergiant Fast X-ray Transients

    CERN Document Server

    Sidoli, Lara

    2011-01-01

    The phenomenology of a subclass of High Mass X-ray Binaries hosting a blue supergiant companion, the so-called Supergiant Fast X-ray Transients (SFXTs), is reviewed. Their number is growing, mainly thanks to the discoveries performed by the INTEGRAL satellite, then followed by soft X-rays observations (both aimed at refining the source position and at monitoring the source behavior) leading to the optical identification of the blue supergiant nature of the donor star. Their defining properties are a transient X-ray activity consisting of sporadic, fast and bright flares, (each with a variable duration between a few minutes and a few hours), reaching 1E36-1E37 erg/s. The quiescence is at a luminosity of 1E32 erg/s, while their more frequent state consists of an intermediate X-ray emission of 1E33-1E34 erg/s (1-10 keV). Only the brightest flares are detected by INTEGRAL (>17 keV) during short pointings, with no detected persistent emission. The physical mechanism driving the short outbursts is still debated, al...

  18. X-ray emission processes in stars

    CERN Document Server

    Testa, Paola

    2010-01-01

    A decade of X-ray stellar observations with Chandra and XMM-Newton has led to significant advances in our understanding of the physical processes at work in hot (magnetized) plasmas in stars and their immediate environment, providing new perspectives and challenges, and in turn the need for improved models. The wealth of high-quality stellar spectra has allowed us to investigate, in detail, the characteristics of the X-ray emission across the HR diagram. Progress has been made in addressing issues ranging from classical stellar activity in stars with solar-like dynamos (such as flares, activity cycles, spatial and thermal structuring of the X-ray emitting plasma, evolution of X-ray activity with age), to X-ray generating processes (e.g. accretion, jets, magnetically confined winds) that were poorly understood in the pre-Chandra/XMM-Newton era. I discuss the progress made in the study of high energy stellar physics and its impact in a wider astrophysical context, focusing on the role of spectral diagnostics no...

  19. Compact X-ray sources: X-rays from self-reflection

    Science.gov (United States)

    Mangles, Stuart P. D.

    2012-05-01

    Laser-based particle acceleration offers a way to reduce the size of hard-X-ray sources. Scientists have now developed a simple scheme that produces a bright flash of hard X-rays by using a single laser pulse both to generate and to scatter an electron beam.

  20. X-ray Spectral Variation of Eta Carinae through the 2003 X-ray Minimum

    CERN Document Server

    Hamaguchi, K; Gull, T; Ishibashi, K; Pittard, J M; Hillier, D J; Damineli, A; Davidson, K; Nielsen, K E; Kober, G V; Hamaguchi, Kenji; Corcoran, Michael F.; Gull, Theodore; Ishibashi, Kazunori; Pittard, Julian M.; Damineli, Augusto; Davidson, Kris; Nielsen, Krister E.; Kober, Gladys Vieira

    2007-01-01

    We report the results of an X-ray observing campaign on the massive, evolved star Eta Carinae, concentrating on the 2003 X-ray minimum as seen by the XMM-Newton observatory. These are the first spatially-resolved X-ray monitoring observations of the stellar X-ray spectrum during the minimum. The hard X-ray emission, believed to be associated with the collision of Eta Carinae's wind with the wind from a massive companion star, varied strongly in flux on timescales of days, but not significantly on timescales of hours. The lowest X-ray flux in the 2-10 keV band seen by XMM-Newton was only 0.7% of the maximum seen by RXTE just before the X-ray minimum. The slope of the X-ray continuum above 5 keV did not vary in any observation, which suggests that the electron temperature of the hottest plasma associated with the stellar source did not vary significantly at any phase. Through the minimum, the absorption to the stellar source increased by a factor of 5-10 to NH ~3-4E23 cm-2. The thermal Fe XXV emission line show...

  1. Linking Jet Emission, X-ray States and Hard X-ray Tails in the Neutron Star X-ray Binary GX 17+2

    OpenAIRE

    Migliari, S.; Miller-Jones, J. C. A.; Fender, R. P.; Homan, J.; T. Di Salvo; Rothschild, R. E.; Rupen, M P; Tomsick, J. A.; Wijnands, R.; van der Klis, M.

    2007-01-01

    We present the results from simultaneous radio (Very Large Array) and X-ray (Rossi-X-ray Timing Explorer) observations of the Z-type neutron star X-ray binary GX~17+2. The aim is to assess the coupling between X-ray and radio properties throughout its three rapidly variable X-ray states and during the time-resolved transitions. These observations allow us, for the first time, to investigate quantitatively the possible relations between the radio emission and the presence of the hard X-ray tai...

  2. X-ray resonant magnetic scattering ellipsometer

    International Nuclear Information System (INIS)

    It is very difficult to characterize the polarization of a synchrotron radiation source in the soft and/or intermediate x-ray energy region particularly from 1 to 2 keV. Conventional multilayer mirror or single-crystal polarimeters do not work over this energy region because their throughput (the reflectivities combined with the phase shift) becomes insignificant. In this paper, we present a new ellipsometer scheme that is able to fully characterize the polarization of synchrotron radiation sources in this energy region. It is based on the dichroic x-ray resonant ferromagnetic scattering that yields information on both the polarization of the x-ray and the material (element specific) dielectric-constant tensor [C.-C. Kao et al., Phys. Rev. B 50, 9599 (1994)] due to the interband ferromagnetic Kerr effect [B.R. Cooper, Phys. Rev. A 139, 1504 (1965)]. copyright 1996 American Institute of Physics

  3. Simulating X-ray Observations with Python

    CERN Document Server

    ZuHone, John A; Hallman, Eric J; Randall, Scott W; Foster, Adam R; Schmid, Christian

    2014-01-01

    X-ray astronomy is an important tool in the astrophysicist's toolkit to investigate high-energy astrophysical phenomena. Theoretical numerical simulations of astrophysical sources are fully three-dimensional representations of physical quantities such as density, temperature, and pressure, whereas astronomical observations are two-dimensional projections of the emission generated via mechanisms dependent on these quantities. To bridge the gap between simulations and observations, algorithms for generating synthetic observations of simulated data have been developed. We present an implementation of such an algorithm in the yt analysis software package. We describe the underlying model for generating the X-ray photons, the important role that yt and other Python packages play in its implementation, and present a detailed workable example of the creation of simulated X-ray observations.

  4. X-Ray Detector Simulations - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Tina, Adrienne [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-20

    The free-electron laser at LCLS produces X-Rays that are used in several facilities. This light source is so bright and quick that we are capable of producing movies of objects like proteins. But making these movies would not be possible without a device that can detect the X-Rays and produce images. We need X-Ray cameras. The challenges LCLS faces include the X-Rays’ high repetition rate of 120 Hz, short pulses that can reach 200 femto-seconds, and extreme peak brightness. We need detectors that are compatible with this light source, but before they can be used in the facilities, they must first be characterized. My project was to do just that, by making a computer simulation program. My presentation discusses the individual detectors I simulated, the details of my program, and how my project will help determine which detector is most useful for a specific experiment.

  5. X-ray optics developments at ESA

    DEFF Research Database (Denmark)

    Bavdaz, M.; Wille, E.; Wallace, K.;

    2013-01-01

    Future high energy astrophysics missions will require high performance novel X-ray optics to explore the Universe beyond the limits of the currently operating Chandra and Newton observatories. Innovative optics technologies are therefore being developed and matured by the European Space Agency (ESA......) in collaboration with research institutions and industry, enabling leading-edge future science missions. Silicon Pore Optics (SPO) [1 to 21] and Slumped Glass Optics (SGO) [22 to 29] are lightweight high performance X-ray optics technologies being developed in Europe, driven by applications in observatory class...... reflective coatings [30 to 35]. In addition, the progress with the X-ray test facilities and associated beam-lines is discussed [36]. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  6. X- rays and matter- the basic interactions

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens

    2008-01-01

    In this introductory article we attempt to provide the theoretical basis for developing the interaction between X-rays and matter, so that one can unravel properties of matter by interpretation of X-ray experiments on samples. We emphasize that we are dealing with the basics, which means that we...... shall limit ourselves to a discussion of the interaction of an X-ray photon with an isolated atom, or rather with a single electron in a Hartree-Fock atom. Subsequent articles in this issue deal with more complicated - and interesting - forms of matter encompassing many atoms or molecules. To cite...... this article: J. Als-Nielsen, C. R. Physique 9 (2008). Udgivelsesdato: 18 April...

  7. X-Ray Wakes in Abell 160

    CERN Document Server

    Drake, N; Sakelliou, I; Pinkney, J C; Drake, Nick; Merrifield, Michael R.; Sakelliou, Irini; Pinkney, Jason C.

    2000-01-01

    `Wakes' of X-ray emission have now been detected trailing behind a few (at least seven) elliptical galaxies in clusters. To quantify how widespread this phenomenon is, and what its nature might be, we have obtained a deep (70 ksec) X-ray image of the poor cluster Abell 160 using the ROSAT HRI. Combining the X-ray data with optical positions of confirmed cluster members, and applying a statistic designed to search for wake-like excesses, we confirm that this phenomenon is observed in galaxies in this cluster. The probability that the detections arise from chance is less than 0.0038. Further, the wakes are not randomly distributed in direction, but are preferentially oriented pointing away from the cluster centre. This arrangement can be explained by a simple model in which wakes arise from the stripping of their host galaxies' interstellar media due to ram pressure against the intracluster medium through which they travel.

  8. The Chandra X-Ray Optics

    CERN Document Server

    Weisskopf, Martin C

    2011-01-01

    Significant advances in science always take place when the state of the art in instrumentation improves dramatically. NASA's Chandra X-Ray Observatory represents such an advance. Launched in July of 1999, Chandra is an observatory designed to study the x-ray emission from all categories of astronomical objects --- from comets, planets, and normal stars to quasars, galaxies, and clusters of galaxies. At the heart of this observatory is the precision X-Ray optic that has been vital for Chandra's outstanding success and which features an angular resolution improved by an order of magnitude compared to its forerunners. The Chandra mission is now entering its 13-th year of operation. Given that the Observatory was designed for a minimum of 3 years of operation testifies to its robust and carefully thought out design. We review the design and construction of the remarkable telescope, present examples of its usage for astronomy and astrophysics, and speculate upon the future.

  9. Electromagnetically induced transparency for x rays

    CERN Document Server

    Buth, Christian; Young, Linda

    2007-01-01

    Electromagnetically induced transparency (EIT) is predicted for x rays in laser-dressed neon gas. The x-ray photoabsorption cross section and polarizability near the Ne K edge are calculated using an ab initio theory suitable for optical strong-field problems. The laser wavelength is tuned close to the transition between 1s^-1 3s and 1s^-1 3p (approximately 800nm). The minimum laser intensity required to observe EIT is of the order of 10^12 W/cm^2. The ab initio results are discussed in terms of an exactly solvable three-level model. This work opens new opportunities for research with ultrafast x-ray sources.

  10. The quantum X-ray radiology apparatus

    CERN Document Server

    Hilt, B; Prevot, G

    2000-01-01

    The paper entitled 'New Quantum Detection System for Very Low Dose X-ray Radiology', presented at the talk session, discusses the preliminary data obtained using a new quantum X-ray radiology system with a high-efficiency solid-state detector and highly sensitive electronics, making it possible to reduce significantly the dose administered to a patient in X-ray radiology examinations. The present paper focuses more on the technological aspects of the apparatus, such as the integration of the detector with the two Asics, and the computer system. Namely, it is shown how the computer system calibrates the detection system, acquires the data in real time, and controls the scan parameters and image filtering process.

  11. Supernova remnants: the X-ray perspective

    Science.gov (United States)

    Vink, Jacco

    2012-12-01

    Supernova remnants are beautiful astronomical objects that are also of high scientific interest, because they provide insights into supernova explosion mechanisms, and because they are the likely sources of Galactic cosmic rays. X-ray observations are an important means to study these objects. And in particular the advances made in X-ray imaging spectroscopy over the last two decades has greatly increased our knowledge about supernova remnants. It has made it possible to map the products of fresh nucleosynthesis, and resulted in the identification of regions near shock fronts that emit X-ray synchrotron radiation. Since X-ray synchrotron radiation requires 10-100 TeV electrons, which lose their energies rapidly, the study of X-ray synchrotron radiation has revealed those regions where active and rapid particle acceleration is taking place. In this text all the relevant aspects of X-ray emission from supernova remnants are reviewed and put into the context of supernova explosion properties and the physics and evolution of supernova remnants. The first half of this review has a more tutorial style and discusses the basics of supernova remnant physics and X-ray spectroscopy of the hot plasmas they contain. This includes hydrodynamics, shock heating, thermal conduction, radiation processes, non-equilibrium ionization, He-like ion triplet lines, and cosmic ray acceleration. The second half offers a review of the advances made in field of X-ray spectroscopy of supernova remnants during the last 15 year. This period coincides with the availability of X-ray imaging spectrometers. In addition, I discuss the results of high resolution X-ray spectroscopy with the Chandra and XMM-Newton gratings. Although these instruments are not ideal for studying extended sources, they nevertheless provided interesting results for a limited number of remnants. These results provide a glimpse of what may be achieved with future microcalorimeters that will be available on board future X-ray

  12. Position sensitive x-ray detector

    International Nuclear Information System (INIS)

    A multi ware position sensitive gas counter for X-ray detection was developed in our laboratory, making use of commercial delay-lines for position sensing. Six delay-line chips (50 ns delay each, 40 Mhz cut-off frequency) cover a total sensitive length of 150 mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9 keV X-ray line from a 55 Fe source and integral linearity better than 0,1% and a maximal differential linearity of ±4,0% were obtained operating the detector with an Ar-C H4 (90%-10%) gas mixture at 700 torr. Similar tests were performed, using the 8,04 keV line from a Cu x-ray tube. A total resolution of 330 μm, and the same integral and differential linearities were obtained. (author)

  13. X-ray detectors in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Spahn, Martin, E-mail: martin.spahn@siemens.com [Siemens AG, Healthcare Sector, Imaging and Therapy Systems, 91301 Forchheim (Germany)

    2013-12-11

    Healthcare systems are subject to continuous adaptation, following trends such as the change of demographic structures, the rise of life-style related and chronic diseases, and the need for efficient and outcome-oriented procedures. This also influences the design of new imaging systems as well as their components. The applications of X-ray imaging in the medical field are manifold and have led to dedicated modalities supporting specific imaging requirements, for example in computed tomography (CT), radiography, angiography, surgery or mammography, delivering projection or volumetric imaging data. Depending on the clinical needs, some X-ray systems enable diagnostic imaging while others support interventional procedures. X-ray detector design requirements for the different medical applications can vary strongly with respect to size and shape, spatial resolution, frame rates and X-ray flux, among others. Today, integrating X-ray detectors are in common use. They are predominantly based on scintillators (e.g. CsI or Gd{sub 2}O{sub 2}S) and arrays of photodiodes made from crystalline silicon (Si) or amorphous silicon (a-Si) or they employ semiconductors (e.g. Se) with active a-Si readout matrices. Ongoing and future developments of X-ray detectors will include optimization of current state-of-the-art integrating detectors in terms of performance and cost, will enable the usage of large size CMOS-based detectors, and may facilitate photon counting techniques with the potential to further enhance performance characteristics and foster the prospect of new clinical applications.

  14. Strong X-ray emission from electrified insulators.

    Science.gov (United States)

    Inada, Nobuya; Maeda, Kuniko; Kawai, Jun

    2005-07-01

    Terasawa reported strong X-ray emission from charged-up insulators, and proposed an X-ray production device only using the electrification. We constructed a similar device and studied the conditions of X-ray emission. It was shown that X-rays could be produced without supplying electrons from a filament. PMID:16038514

  15. Marriage of x-ray and optical astronomy

    International Nuclear Information System (INIS)

    An historical discussion of the relation of x-ray and optical astronomy is given including distances within our galaxy, the optical identification of x-ray sources, the binary x-ray stars, neutron stars and black holes, a program in x-ray astronomy, and future missions

  16. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography.

    Directory of Open Access Journals (Sweden)

    Susan Zappala

    Full Text Available X-ray Computed Tomography (CT is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy. However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored.

  17. Energy resolved X-ray grating interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Thuering, T.; Stampanoni, M. [Swiss Light Source, Paul Scherrer Institut, Villigen PSI (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology, Zurich (Switzerland); Barber, W. C.; Iwanczyk, J. S. [DxRay, Inc., Northridge, California 91324 (United States); Seo, Y.; Alhassen, F. [UCSF Physics Research Laboratory, Department of Radiology and Biomedical Imaging, University of California, San Francisco, California 94143 (United States)

    2013-05-13

    Although compatible with polychromatic radiation, the sensitivity in X-ray phase contrast imaging with a grating interferometer is strongly dependent on the X-ray spectrum. We used an energy resolving detector to quantitatively investigate the dependency of the noise from the spectral bandwidth and to consequently optimize the system-by selecting the best energy band matching the experimental conditions-with respect to sensitivity maximization and, eventually, dose. Further, since theoretical calculations of the spectrum are usually limited due to non-ideal conditions, an energy resolving detector accurately quantifies the spectral changes induced by the interferometer including flux reduction and beam hardening.

  18. Tantalum/Copper X-Ray Targets

    Science.gov (United States)

    Waters, William J.; Edmonds, Brian

    1993-01-01

    Lewis Research Center developed unique solution to subsidiary problem of fabrication of x-ray target. Plasma spraying enabled fabrication of lightweight, high-performance targets. Power settings, atmosphere-control settings, rate of deposition, and other spraying parameters developed. Thin coats of tantalum successfully deposited on copper targets. Targets performed successfully in tests and satisfied all criteria expressed in terms of critical parameters. Significantly reduces projected costs of fabrication of targets and contributes to development of improved, long-lived, lightweight x-ray system.

  19. Atomic Data for X-ray Astrophysics

    CERN Document Server

    Kallman, T R

    2006-01-01

    We review the available atomic data used for interpreting and modeling X-ray observations. The applications for these data can be divided into several levels of detail, ranging from compilations which can be used with direct inspection of raw data, such as line finding lists, to synthetic spectra which attempt to fit to an entire observed dataset simultaneously. This review covers cosmic sources driven by both electron ionization and photoionization and touches briefly on planetary surfaces and atmospheres. We review all of this, the applications to X-ray astronomy, the available data, recommendations for astronomical users, and attempt to point out the applications where the shortcomings are greatest

  20. X-Ray Transition Energies Database

    Science.gov (United States)

    SRD 128 X-Ray Transition Energies Database (Web, free access)   This X-ray transition table provides the energies and wavelengths for the K and L transitions connecting energy levels having principal quantum numbers n = 1, 2, 3, and 4. The elements covered include Z = 10, neon to Z = 100, fermium. There are two unique features of this data base: (1) a serious attempt to have all experimental values on a scale consistent with the International System of measurement (the SI) and (2) inclusion of accurate theoretical estimates for all transitions.

  1. Commercial Applications of X Ray Spectrometric Techniques

    International Nuclear Information System (INIS)

    In the 21st century, the X-ray fluorescence (XRF) technique is widely used in process control, industrial applications and for routine elemental analysis. The technique has a multielement capability capable of detecting elements with Z ≥ 10, with a few instruments capable of detecting also elements with Z ≥ 5. It is characterized by a non-destructive analysis process and relatively good detection limits, typically one part per million, for a wide range of elements. The first commercial XRF instruments were introduced to the market about 50 years ago. They were the wavelength dispersive X ray fluorescence (WDXRF) spectrometers utilizing Bragg’s law and reflection on crystal lattices for sequential elemental analysis of sample composition. The advances made in radiation detector technology, especially the introduction of semiconductor detectors, improvements in signal processing electronics, availability and exponential growth of personal computer market led to invention of energy dispersive X ray fluorescence (EDXRF) technique. The EDXRF is more cost effective as compared to WDXRF. It also allows for designing compact instruments. Such instruments can be easily tailored to the needs of different customers, integrated with industrial installations, and also miniaturized for the purpose of in-situ applications. The versatility of the technique has been confirmed in a spectacular way by using the XRF and X-ray spectrometric techniques, among few others, during the NASA and ESA missions in search for the evidence of life and presence of water on the surface of Mars. The XRF technique has achieved its strong position within the atomic spectroscopy group of analytical techniques not only due to its versatility but also due to relatively low running costs, as compared to the commonly used methods, e.g., atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission/mass spectrometry (ICP-AES/MS). Presently, the XRF technique together with X ray

  2. Radiobiological studies using gamma and x rays.

    Energy Technology Data Exchange (ETDEWEB)

    Potter, Charles Augustus; Longley, Susan W.; Scott, Bobby R.; Lin, Yong; Wilder, Julie; Hutt, Julie A.; Padilla, Mabel T.; Gott, Katherine M.

    2013-02-01

    There are approximately 500 self-shielded research irradiators used in various facilities throughout the U.S. These facilities use radioactive sources containing either 137Cs or 60Co for a variety of biological investigations. A report from the National Academy of Sciences[1] described the issues with security of particular radiation sources and the desire for their replacement. The participants in this effort prepared two peer-reviewed publications to document the results of radiobiological studies performed using photons from 320-kV x rays and 137Cs on cell cultures and mice. The effectiveness of X rays was shown to vary with cell type.

  3. Dose levels in conventional X-rays

    International Nuclear Information System (INIS)

    There were a series of measures in the General Hospital of Fresnillo in the X-ray Department in the areas of X-1 and X-2-ray rooms and in the neonatal intensive care unit 2, was determined the dose surface entry in eyes, thyroid and gonads for patients undergoing to X-ray study of chest Tele by thermoluminescent dosimetry. Five dosemeters were used in each one of the scans; so find the following dose ranges 20 +- 23 mGy to 350 +- 41 mGy. With the results obtained we can conclude that the procedures used and the equipment calibration is adequate. (Author)

  4. Cosmology with X-ray Cluster Baryons

    Energy Technology Data Exchange (ETDEWEB)

    Linder, Eric V.

    2007-04-10

    X-ray cluster measurements interpreted with a universal baryon/gas mass fraction can theoretically serve as a cosmological distance probe. We examine issues of cosmological sensitivity for current (e.g., Chandra X-ray Observatory, XMM-Newton) and next generation (e.g., Con-X, XEUS) observations, along with systematic uncertainties and biases. To give competitive next generation constraints on dark energy, we find that systematics will need to be controlled to better than 1percent and any evolution in f_gas (and other cluster gas properties) must be calibrated so the residual uncertainty is weaker than (1+z)0.03.

  5. X-ray tomography detection methods

    International Nuclear Information System (INIS)

    The improvement in the performance of X-ray tomographs involves the study of more efficient detectors, hence the important effort now being undertaken by various teams in the design of new detection systems. After defining the parameters which make it possible to select a detection method for an X-ray tomograph, the technical and operating characteristics of the following detectors are briefly reviewed: gas ionization chamber, multiwire grid chambers, ionization chamber with a condensed medium (liquid xenon), scintillation detector (with scintillator and photodetector) and semiconductor detectors (CdTe and HgI2) operating at ambient temperature

  6. Ultrafast x-ray-induced nuclear dynamics in diatomic molecules using femtosecond x-ray-pump-x-ray-probe spectroscopy

    Science.gov (United States)

    Lehmann, C. S.; Picón, A.; Bostedt, C.; Rudenko, A.; Marinelli, A.; Moonshiram, D.; Osipov, T.; Rolles, D.; Berrah, N.; Bomme, C.; Bucher, M.; Doumy, G.; Erk, B.; Ferguson, K. R.; Gorkhover, T.; Ho, P. J.; Kanter, E. P.; Krässig, B.; Krzywinski, J.; Lutman, A. A.; March, A. M.; Ray, D.; Young, L.; Pratt, S. T.; Southworth, S. H.

    2016-07-01

    The capability of generating two intense, femtosecond x-ray pulses with a controlled time delay opens the possibility of performing time-resolved experiments for x-ray-induced phenomena. We have applied this capability to study the photoinduced dynamics in diatomic molecules. In molecules composed of low-Z elements, K -shell ionization creates a core-hole state in which the main decay mode is an Auger process involving two electrons in the valence shell. After Auger decay, the nuclear wave packets of the transient two-valence-hole states continue evolving on the femtosecond time scale, leading either to separated atomic ions or long-lived quasibound states. By using an x-ray pump and an x-ray probe pulse tuned above the K -shell ionization threshold of the nitrogen molecule, we are able to observe ion dissociation in progress by measuring the time-dependent kinetic energy releases of different breakup channels. We simulated the measurements on N2 with a molecular dynamics model that accounts for K -shell ionization, Auger decay, and the time evolution of the nuclear wave packets. In addition to explaining the time-dependent feature in the measured kinetic energy release distributions from the dissociative states, the simulation also reveals the contributions of quasibound states.

  7. X-ray shout echoing through space

    Science.gov (United States)

    2004-01-01

    a flash of X-rays hi-res Size hi-res: 3991 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in hours. At their largest size, the rings would appear in the sky about five times smaller than the full moon. a flash of X-rays hi-res Size hi-res: 2153 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays (Please choose "hi-res" version for animation) XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in seconds. At their largest size, the rings would appear in the sky about five times smaller than the full moon. This echo forms when the powerful radiation of a gamma-ray burst, coming from far away, crosses a slab of dust in our Galaxy and is scattered by it, like the beam of a lighthouse in clouds. Using the expanding rings to precisely pin-point the location of this dust, astronomers can identify places where new stars and planets are likely to form. On 3 December 2003 ESA's observatory, Integral, detected a burst of gamma rays, lasting about 30 seconds, from the direction of a distant galaxy. Within minutes of the detection, thanks to a sophisticated alert network, many

  8. Radiation hygiene aspects of dental X-ray diagnosis

    International Nuclear Information System (INIS)

    The dental X-rays are among the most frequent types of X-ray examinations performed in Bulgaria. Over the past decade, the share of these investigations has ranged from 20 to 30% of all X-rays performed in the country. This communication considers the following radiation-health problems involved in dental X-ray diagnosis: frequency of dental X-ray examinations and the contribution of the standard and nonstandard examinations towards radiation doses received by patients. (author)

  9. An X-ray and optical study of the ultracompact X-ray binary A 1246-58

    NARCIS (Netherlands)

    in 't Zand, J. J. M.; Bassa, C. G.; Keek, L.; Verbunt, F.; Mendez, M.; Markwardt, C. B.; Jonker, P.G.

    2008-01-01

    Results are discussed of an X-ray and optical observation campaign of the low-mass X-ray binary A 1246-58 performed with instruments on Satellite per Astronomia X ("BeppoSAX"), the Rossi X-ray Timing Explorer (RXTE), the X-ray Multi-mirror Mission ("XMM-Newton"), the Swift mission, and the Very Larg

  10. An X-ray and optical study of the ultracompact X-ray binary A1246-58

    NARCIS (Netherlands)

    Zand, J. J. M. in 't

    2008-01-01

    Results are discussed of an X-ray and optical observation campaign of the low-mass X-ray binary A 1246-58 performed with instruments on Satellite per Astronomia X (’BeppoSAX’), the Rossi X-ray Timing Explorer (RXTE), the X-ray Multi-mirror Mission (’XMM-Newton’), the Swift mission, and the Very Larg

  11. X-ray Chirped Pulse Amplification: towards GW Soft X-ray Lasers

    Directory of Open Access Journals (Sweden)

    Marta Fajardo

    2013-07-01

    Full Text Available Extensive modeling of the seeding of plasma-based soft X-ray lasers is reported in this article. Seminal experiments on amplification in plasmas created from solids have been studied in detail and explained. Using a transient collisional excitation scheme, we show that a 18 µJ, 80 fs fully coherent pulse is achievable by using plasmas pumped by a compact 10 Hz laser. We demonstrate that direct seeding of plasmas created by nanosecond lasers is not efficient. Therefore, we propose and fully study the transposition to soft X-rays of the Chirped Pulse Amplification (CPA technique. Soft X-ray pulses with energy of 6 mJ and 200 fs duration are reachable by seeding plasmas pumped by compact 100 J, sub-ns, 1 shot/min lasers. These soft X-ray lasers would reach GW power, corresponding to an increase of 100 times as compared to the highest peak power achievable nowadays in the soft X-ray region (30 eV–1 keV. X-ray CPA is opening new horizon for soft x-ray ultra-intense sources.

  12. Demonstration of x-ray holography with an x-ray laser

    International Nuclear Information System (INIS)

    X-ray holography offers the potential for obtaining high resolution three-dimensional images of in vitro biological microstructures. Significant progress toward this goal has been achieved with holography systems using synchrotron x-ray sources and recently spatial resolutions as small as 40 nm have been demonstrated. These experiments required x-ray exposures of an hour or longer, which makes high spatial resolution difficult to achieve in live biological specimens because of blurring of the image. This blurring is caused by specimen motion and prohibits the imaging of dynamical processes within the specimen. A possible solution to this problem is to exploit the extremely high brightness and long coherence lengths produced by x-ray lasers and create the hologram with exposure times of less than 1 nsec. This report presents the results from an experiment in which an x-ray laser was used to produce x-ray holograms. The holography geometry used was a Gabor in-line type modified by the inclusion of a high reflectivity multi-layer x-ray mirror used as a narrow bandpass filter

  13. Material Discriminated X-Ray CT System by Using New X-Ray Imager with Energy Discriminate Function

    OpenAIRE

    Toru Aoki; Takuya Nakashima; Hisashi Morii; Yoichiro Neo; Hidenori Mimura

    2008-01-01

    Material discriminated X-ray CT system has been constructed by using conventional X-ray tube (white X-ray source) and photon-counting X-ray imager as an application with energy band detection. We have already reported material identify X-ray CT using K-shell edge method elsewhere. In this report the principle of material discrimination was adapted the separation of electron-density and atomic number from attenuation coefficient mapping in X-ray CT reconstructed image in two wavelength X-ray C...

  14. On the X-ray properties of V Sge and its relation to the supersoft X-ray binaries

    OpenAIRE

    Greiner, Jochen; van Teeseling, Andre

    1998-01-01

    We investigate the ROSAT X-ray properties of V Sge, which has been proposed to be related to supersoft X-ray binaries. During optical bright states, V Sge is a faint hard X-ray source, while during optical faint states (V >=12 mag), V Sge is a `supersoft' X-ray source. Spectral fitting confirms that V~Sge's X-ray properties during its soft X-ray state may be similar to those of supersoft X-ray binaries, although a much lower luminosity cannot be excluded. It is possible to explain the differe...

  15. X-ray spectroscopy: Enlightened state

    Science.gov (United States)

    McCusker, James K.

    2014-07-01

    Determining the sequence of events following photon absorption by a molecule can be a surprisingly challenging task. An innovative use of time-resolved X-ray spectroscopy has revealed an important insight into the ultrafast excited-state dynamics of a well-known inorganic chromophore.

  16. X-rays from neutron stars

    International Nuclear Information System (INIS)

    The basic theoretical in the models of regularly pulsating X-ray sources are discussed, and put in relation to the observations. The topics covered include physics of the magnetosphere of an accreting neutron star, hydrodynamics of the accretion column, physical processes close to the surface of the neutron star such as proton-electron collisions, photon-electron interactions. (orig.)

  17. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  18. X-ray lasers at MBI

    Science.gov (United States)

    Janulewicz, Karol A.; Lucianetti, Antonio; Priebe, Gerd; Sandner, Wolfgang; Nickles, Peter-Viktor

    2003-10-01

    The state-of-the-art and the trends in development of table-top soft x-ray lasers (XRLs) with a special emphasis on the work of the Max Born Institute (MBI) are presented. Both, basic physics and some features of the output radiation crucial for applications are discussed as well.

  19. Magnetic X-ray diffraction from samarium

    Energy Technology Data Exchange (ETDEWEB)

    Watson, D. [School of Physics and Space Research, University of Birmingham, Birmingham B15 2TT (United Kingdom); Forgan, E.M. [School of Physics and Space Research, University of Birmingham, Birmingham B15 2TT (United Kingdom); Stirling, W.G. [Department of Physics, University of Keele, Keele, Staffs ST5 5BG (United Kingdom); Nuttall, W.J. [Department of Physics, University of Keele, Keele, Staffs ST5 5BG (United Kingdom); Perry, S.C. [Department of Physics, University of Keele, Keele, Staffs ST5 5BG (United Kingdom); Costa, M.M.R. [Physics Department, Universidade de Coimbra, 3000 Coimbra (Portugal); Fort, D. [School of Metallurgy and Materials, University of Birmingham, Birmingham B15 2TT (United Kingdom)

    1995-02-09

    We report X-ray scattering observations on antiferromagnetic samarium, using the NSLS synchrotron source. We have made new observations of the absorption-corrected energy dependence and temperature variation of the resonantly enhanced magnetic signal from the hexagonal sites near the L{sub III} edge. ((orig.)).

  20. Skull X-Rays for Head Injury

    OpenAIRE

    J Gordon Millichap

    2005-01-01

    The effect of abolishing skull X-rays on the rate of admission, use of computer tomography (CT), radiation dose per head injury, and detection of intracranial injuries was determined in patients, aged 1 to 14 years, presenting to the ED at Royal Hospital for Sick Children, Edinburgh, UK.

  1. Femtosecond X-ray protein nanocrystallography

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Henry N. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Univ. of Hamburg (Germany); Barty, Anton [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; White, Thomas A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Aquila, Andrew [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Schulz, Joachim [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; DePonte, Daniel P. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Martin, Andrew V. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Coppola, Nicola [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Liang, Mengning [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Caleman, Carl [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Gumprecht, Lars [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Stern, Stephan [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science; Nass, Karol [Univ. of Hamburg (Germany); Fromme, Petra [Arizona State Univ., Tempe, AZ (United States). Dept. of Chemistry and Biochemistry; Hunter, Mark S. [Arizona State Univ., Tempe, AZ (United States). Dept. of Chemistry and Biochemistry; Grotjohann, Ingo [Arizona State Univ., Tempe, AZ (United States). Dept. of Chemistry and Biochemistry; Fromme, Raimund [Arizona State Univ., Tempe, AZ (United States). Dept. of Chemistry and Biochemistry; Kirian, Richard A. [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Weierstall, Uwe [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Doak, R. Bruce [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Schmidt, Kevin E. [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Wang, Xiaoyu [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Spence, John C. H. [Arizona State Univ., Tempe, AZ (United States). Dept. of Physics; Schlichting, Ilme [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Epp, Sascha W. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Rolles, Daniel [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Rudenko, Artem [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Foucar, Lutz [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Rudek, Benedikt [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Erk, Benjamin [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Schmidt, Carlo [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Hömke, André [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Strüder, Lothar [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Society Semiconductor Lab., Munich (Germany); Ullrich, Joachim [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Krasniqi, Faton [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Center for Free-Electron Laser Science, Max Planck Advanced Study Group; Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Lomb, Lukas [Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Shoeman, Robert L. [Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Bott, Mario [Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Barends, Thomas R. M. [Max Planck Inst. fur Medizinische Forschung, Heidelberg (Germany); Kuhnel, Kai-Uwe [Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Schroter, Claus-Dieter [Max Planck Inst. fur Kernphysik, Heidelberg (Germany); Hartmann, Robert [PNSensor GmbH, Munich (Germany); Holl, Peter [PNSensor GmbH, Munich (Germany); Reich, Christian [PNSensor GmbH, Munich (Germany); Soltau, Heike [PNSensor GmbH, Munich (Germany); Kimmel, Nils [Max Planck Society Semiconductor Lab., Munich (Germany); Weidenspointner, Georg [Max Planck Society Semiconductor Lab., Munich (Germany); Max Planck Inst. fur Extraterrestrische Physik, Garching (Germany); Pietschner, Daniel [Max Planck Society Semiconductor Lab., Munich (Germany); Hauser, Günter [Max Planck Society Semiconductor Lab., Munich (Germany); Herrmann, Sven [Max Planck Society Semiconductor Lab., Munich (Germany); Schaller, Gerhard [Max Planck Society Semiconductor Lab., Munich (Germany); Schopper, Florian [Max Planck Society Semiconductor Lab., Munich (Germany); Andritschke, Robert [Max Planck Society Semiconductor Lab., Munich (Germany); Boutet, Sébastien [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Krzywinski, Jacek [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Bostedt, Christoph [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Messerschmidt, Marc [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Bozek, John D. [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Williams, Garth J. [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS); Bogan, Michael J. [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Hampton, Christina Y. [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Sierra, Raymond G. [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Starodub, Dmitri [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Gorke, Hubert [Forschungszentrum Julich (Germany); Hau-Riege, Stefan P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frank, Matthias [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Maia, Filipe R. N. C. [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Hajdu, Janos [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Timneanu, Nicusor [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Seibert, M. Marvin [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Andreasson, Jakob [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Rocker, Andrea [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Jönsson, Olof [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Svenda, Martin [Uppsala Univ. (Sweden). Dept. of Cell and Molecular Biology, Lab. of Molecular Biophysics; Holton, James M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Marchesini, Stefano [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Neutze, Richard [Univ. of Gothenburg (Sweden). Dept. of Chemistry, Biochemistry and Biophysics; Schorb, Sebastian [Technische Univ. Berlin (Germany). Inst. fur Optik und Atomare Physik (IOAP); Rupp, Daniela [Technische Univ. Berlin (Germany). Inst. fur Optik und Atomare Physik (IOAP); Adolph, Marcus [Technische Univ. Berlin (Germany). Inst. fur Optik und Atomare Physik (IOAP); Gorkhover, Tais [Technische Univ. Berlin (Germany). Inst. fur Optik und Atomare Physik (IOAP); Andersson, Inger [Swedish Univ. of Agricultural Sciences, Uppsala Biomedical Centre, Uppsala, (Sweden). Dept. of Molecular Biology; Barthelmess, Miriam [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science; Bajt, Saša [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science; Hirsemann, Helmut [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science; Potdevin, Guillaume [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science; Graafsma, Heinz [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science; Nilsson, Björn [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany). Photon Science

    2011-02-03

    X-ray crystallography provides the vast majority of macromolecular structures, but the success of the method relies on growing crystals of sufficient size. In conventional measurements, the necessary increase in X-ray dose to record data from crystals that are too small leads to extensive damage before a diffraction signal can be recorded. It is particularly challenging to obtain large, well-diffracting crystals of membrane proteins, for which fewer than 300 unique structures have been determined despite their importance in all living cells. Here we present a method for structure determination where single-crystal X-ray diffraction ‘snapshots’ are collected from a fully hydrated stream of nanocrystals using femtosecond pulses from a hard-X-ray free-electron laser, the Linac Coherent Light Source. We prove this concept with nanocrystals of photosystem I, one of the largest membrane protein complexes. More than 3,000,000 diffraction patterns were collected in this study, and a three-dimensional data set was assembled from individual photosystem I nanocrystals (~200 nm to 2 μm in size). We mitigate the problem of radiation damage in crystallography by using pulses briefer than the timescale of most damage processes. This offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage.

  2. X-ray optics for axion helioscopes

    DEFF Research Database (Denmark)

    Jakobsen, Anders Clemen; Pivovaroff, Michael J.; Christensen, Finn Erland

    2013-01-01

    A method of optimizing grazing incidence x-ray coatings in ground based axion helioscopes is presented. Software has been been developed to find the optimum coating when taking both axion spectrum and Micromegas detector quantum efficiency into account. A comparison of the relative effective area...... of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  3. Outbursts in ultracompact X-ray binaries

    CERN Document Server

    Hameury, J -M

    2016-01-01

    Very faint X-ray binaries appear to be transient in many cases with peak luminosities much fainter than that of usual soft X-ray transients, but their nature still remains elusive. We investigate the possibility that this transient behaviour is due to the same thermal/viscous instability which is responsible for outbursts of bright soft X-ray transients, occurring in ultracompact binaries for adequately low mass-transfer rates. More generally, we investigate the observational consequences of this instability when it occurs in ultracompact binaries. We use our code for modelling the thermal-viscous instability of the accretion disc, assumed here to be hydrogen poor. We also take into account the effects of disc X-ray irradiation, and consider the impact of the mass-transfer rate on the outburst brightness. We find that one can reproduce the observed properties of both the very faint and the brighter short transients (peak luminosity, duration, recurrence times), provided that the viscosity parameter in quiesce...

  4. X-ray lasers and crystallography

    OpenAIRE

    Spence, John C. H.

    2014-01-01

    The development of X-ray lasers and their applications in crystallography is described. In the birth of this new field, IUCrJ is ideally positioned to present this research to both specialists in crystallography, and to the wider audience in structural biology.

  5. Fourier techniques in X-ray timing

    NARCIS (Netherlands)

    M. van der Klis

    1988-01-01

    Basic principles of Fourier techniques often used in X-ray time series analysis are reviewed. The relation between the discrete Fourier transform and the continuous Fourier transform is discussed to introduce the concepts of windowing and aliasing. The relation is derived between the power spectrum

  6. Exploring subluminous X-ray binaries

    NARCIS (Netherlands)

    N.D. Degenaar

    2010-01-01

    Halfway the twentieth century, technological developments made it possible to carry detection instruments outside the absorbing layers of the Earth’s atmosphere onboard rockets and satellites. This opened up the opportunity to detect the emission from celestial objects at X-ray wavelengths, thereby

  7. X-ray voltabsorptometry on redox proteins

    Energy Technology Data Exchange (ETDEWEB)

    Ascone, Isabella [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , P.le A. Moro 5, 00185 Rome (Italy) and LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France)]. E-mail: i.ascone@caspur.it; Zamponi, Silvia [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy); Cognigni, Andrea [LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France); Marmocchi, Franco [Dipartimento di Biologia Molecolare, Cellulare e Animale, Universita di Camerino, Via Camerini, 1 Camerino (Italy); Marassi, Roberto [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy)

    2005-04-15

    Biological X-ray absorption spectroscopy (BioXAS) is able to describe the metal environment in a metalloprotein and is sensitive to metal oxidation state. Coupling of BioXAS and electrochemistry permits the characterization of different oxidation states and avoids uncontrolled protein redox state changes due to X-ray beam irradiation. XAS spectroelectrochemistry requires electrochemical cells specifically designed to meet the requirements of both XAS measurements and electrochemical effectiveness in potential control. In this context, this paper describes a new cell tested with different types of working electrodes developed for BioXAS, in particular for in situ studies of redox proteins. The XAS electrochemical measurements of a relatively high-molecular-weight protein (Cu,Zn superoxide dismutase) for which it is difficult to observe direct electrochemistry have been achieved. New working electrodes, capable of fast and unmediated electron transfer, are described. The cell permits to isolate protein redox states and to measure X-ray absorption intensity during a potential scan (X-ray voltabsorptometry)

  8. Soft x-ray laser microscope

    Energy Technology Data Exchange (ETDEWEB)

    Suckewer, P.I.

    1990-10-01

    The program consisted of two phases (Phase I and Phase II). The goal of the Phase I (first year program) was to design and construct the Soft X-ray Laser Contact Microscope. Such microscope was constructed and adapted to PPL's 18.2nm soft X-ray Laser (SXL), which in turn was modified and prepared for microscopy experiments. Investigation of the photoresist response to 18.2nm laser radiation and transmissivity of 0.1m thick silicion-nitride (Si[sub 3]N[sub 4]) windows were important initial works. The goal of the first year of Phase II was to construct X-ray contact microscope in combination with existing optical phase microscope, already used by biologists. In the second year of Phase II study of dehydrated Horeseshoe Crab and Hela cancer cells were performed with COXRALM. Also during Phase II, the Imaging X-Ray Laser Microscope (IXRALM) was designed and constructed. This paper describes the development of each of the microscopes and their application for research.

  9. Compact stellar X-ray sources

    NARCIS (Netherlands)

    W.H.G. Lewin; M. van der Klis

    2006-01-01

    X-ray astronomy is the prime available window on astrophysical compact objects: black holes, neutron stars and white dwarfs. In the last ten years new observational opportunities have led to an explosion of knowledge in this field. This book provides a comprehensive overview of the astrophysics of c

  10. X-ray signals in renal osteopathy

    Energy Technology Data Exchange (ETDEWEB)

    Rieden, K.

    1984-10-01

    Chronic renal insufficiency is associated with metabolic disturbances which ultimately lead to typical, partly extremely painful changes in the skeletal system the longer the disease persists. Regular X-ray control of certain skeletal segments allows early detection of renal oesteopathy if the radiological findings described in this article are carefully scrutinised and interpreted.

  11. X-ray microscopy of human malaria

    Energy Technology Data Exchange (ETDEWEB)

    Magowan, C.; Brown, J.T.; Mohandas, N.; Meyer-Ilse, W. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    Associations between intracellular organisms and host cells are complex and particularly difficult to examine. X-ray microscopy provides transmission images of subcellular structures in intact cells at resolutions superior to available methodologies. The spatial resolution is 50-60nm with a 1 micron depth of focus, superior to anything achievable with light microscopy. Image contrast is generated by differences in photoelectric absorption by the atoms in different areas (i.e. subcellular structures) throughout the full thickness of the sample. Absorption due to carbon dominates among all the elements in the sample at 2.4 nm x-ray wavelength. Thus images show features or structures, in a way not usually seen by other types of microscopy. The authors used soft x-ray microscopy to investigate structural development of Plasmodium falciparum malaria parasites in normal and genetically abnormal erythrocytes, and in infected erythrocytes treated with compounds that have anti-malarial effects. X-ray microscopy showed newly elaborated structures in the cytosol of unstained, intact erythrocytes, redistribution of mass (carbon) in infected erythrocytes, and aberrant parasite morphology. Better understanding of the process of intracellular parasite maturation and the interactions between the parasite and its host erythrocyte can help define new approaches to the control of this deadly disease.

  12. Massively parallel X-ray holography

    Energy Technology Data Exchange (ETDEWEB)

    Spence, John C.H [Arizona State University; Marchesini, Stefano [Lawrence Berkeley National Laboratory, Berkeley; Boutet, Sebastien [Stanford Synchrotron Radiation Laboratory; Sakdinawat, Anne E. [, Lawrence Berkeley National Laboratory; Bogan, Michael J. [Lawrence Livermore National Laboratory; Bajt, Sasa [Lawrence Livermore National Laboratory; Barty, Anton [Lawrence Livermore National Laboratory; Chapman, Henry N. [Lawrence Livermore National Laboratory; Frank, Matthias [Lawrence Livermore National Laboratory; Hau-Riege, Stefan P. [Lawrence Livermore National Laboratory; Szöke, Abraham [Lawrence Livermore National Laboratory; Cui, Congwu [Lawrence Berkeley National Laboratory; Shapiro, David A. [Lawrence Berkeley National Laboratory; Howells, MAlcolm R. [Lawrence Berkeley National Laboratory; Shaevitz, Joshua W [Lewis-Sigler Institute; Lee, Joanna Y. [University of California, Berkeley; Hajdu, Janos [3Stanford Synchrotron Radiation Laboratory; Seibert, Marvin M. [Uppsala University

    2008-08-01

    Advances in the development of free-electron lasers offer the realistic prospect of nanoscale imaging on the timescale of atomic motions. We identify X-ray Fourier-transform holography1,2,3 as a promising but, so far, inefficient scheme to do this. We show that a uniformly redundant array4 placed next to the sample, multiplies the efficiency of X-ray Fourier transform holography by more than three orders of magnitude, approaching that of a perfect lens, and provides holographic images with both amplitude- and phase-contrast information. The experiments reported here demonstrate this concept by imaging a nano-fabricated object at a synchrotron source, and a bacterial cell with a soft-X-ray free-electron laser, where illumination by a single 15-fs pulse was successfully used in producing the holographic image. As X-ray lasers move to shorter wavelengths we expect to obtain higher spatial resolution ultrafast movies of transient states of matter

  13. XRASE: The X-Ray Spectroscopic Explorer

    DEFF Research Database (Denmark)

    Schnopper, H.W.; Silver, E.; Murray, S.;

    2001-01-01

    eV at 6 keV) and efficiency with a field-of-view of 26 arcmin(2) . A deep orbit allows for long, continuous observations. Monitoring instruments in the optical (WOM-X), UV (TAUVEX) and hard X-RAY (GRAM) bands will offer exceptional opportunities to make simultaneous multi-wavelength observations....

  14. Supernova remnants: the X-ray perspective

    NARCIS (Netherlands)

    J. Vink

    2012-01-01

    Supernova remnants are beautiful astronomical objects that are also of high scientific interest, because they provide insights into supernova explosion mechanisms, and because they are the likely sources of Galactic cosmic rays. X-ray observations are an important means to study these objects. And i

  15. Harmonic lasing in X-ray FELs

    Energy Technology Data Exchange (ETDEWEB)

    Schneidmiller, E.A.; Yurkov, M.V.

    2012-05-15

    Harmonic lasing in a free electron laser with a planar undulator (under the condition that the fundamental frequency is suppressed) might be a cheap and efficient way of extension of wavelength ranges of existing and planned X-ray FEL facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam which is easier to handle due to the suppressed fundamental frequency. In this paper we perform a parametrization of the solution of the eigenvalue equation for lasing at odd harmonics, and present an explicit expression for FEL gain length, taking into account all essential effects. We propose and discuss methods for suppression of the fundamental harmonic. We also suggest a combined use of harmonic lasing and lasing at the retuned fundamental wavelength in order to reduce bandwidth and to increase brilliance of X-ray beam at saturation. Considering 3rd harmonic lasing as a practical example, we come to the conclusion that it is much more robust than usually thought, and can be widely used in the existing or planned X-ray FEL facilities. In particular, LCLS after a minor modification can lase to saturation at the 3rd harmonic up to the photon energy of 25-30 keV providing multi-gigawatt power level and narrow bandwidth. As for the European XFEL, harmonic lasing would allow to extend operating range (ultimately up to 100 keV), to reduce FEL bandwidth and to increase brilliance, to enable two-color operation for pump-probe experiments, and to provide more flexible operation at different electron energies. Similar improvements can be realized in other X-ray FEL facilities with gap-tunable undulators like FLASH II, SACLA, LCLS II, etc. Harmonic lasing can be an attractive option for compact X-ray FELs (driven by electron beams with a relatively low energy), allowing the use of the standard undulator technology instead of small-gap in-vacuum devices. Finally, in this paper we discover that in a part of the

  16. Microfocussing of synchrotron X-rays using X-ray refractive lens developed at Indus-2 deep X-ray lithography beamline

    Indian Academy of Sciences (India)

    V P Dhamgaye; M K Tiwari; K J S Sawhney; G S Lodha

    2014-07-01

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance sources are compared.

  17. Observing Solvation Dynamics with Simultaneous Femtosecond X-ray Emission Spectroscopy and X-ray Scattering

    DEFF Research Database (Denmark)

    Haldrup, Kristoffer; Gawelda, Wojciech; Abela, Rafael;

    2016-01-01

    rearrangement of the solute with X-ray emission spectroscopy, thus establishing time zero for the ensuing X-ray diffuse scattering analysis. The simultaneously recorded X-ray diffuse scattering atterns reveal slower subpicosecond dynamics triggered by the intramolecular structural dynamics of the photoexcited......, confirming previous ab initio molecular dynamics simulations. Structural changes in the aqueous solvent associated with density and temperature changes occur with similar to 1 ps time constants, characteristic for structural dynamics in water. This slower time scale of the solvent response allows us...

  18. The Swift X-ray Telescope Cluster Survey II. X-ray spectral analysis

    OpenAIRE

    P. TozziINAF, Osservatorio Astrofisico di Firenze; A. Moretti(Fermilab, Batavia, IL, USA); Tundo, E.; Liu, T.; Rosati, P.; Borgani, S.; Tagliaferri, G.; S. Campana; Fugazza, D.; Avanzo, P. D.

    2014-01-01

    (Abridged) We present a spectral analysis of a new, flux-limited sample of 72 X-ray selected clusters of galaxies identified with the X-ray Telescope (XRT) on board the Swift satellite down to a flux limit of ~10-14 erg/s/cm2 (SWXCS, Tundo et al. 2012). We carry out a detailed X-ray spectral analysis with the twofold aim of measuring redshifts and characterizing the properties of the Intra-Cluster Medium (ICM). Optical counterparts and spectroscopic or photometric redshifts ...

  19. X-ray variability in a complete sample of Soft X-ray selected AGN

    OpenAIRE

    D. Grupe; Thomas, H. -C.; Beuermann, K.

    2000-01-01

    We present ROSAT All-Sky Survey and ROSAT pointed observations (PSPC and HRI) of a complete sample of 113 bright soft X-ray AGN selected from the ROSAT Bright Source Catalog. We compare these observations in order to search for extreme cases of flux and spectral X-ray variability - X-ray transient AGN. Three definite transients and one transient candidate are found. The other sources show amplitude variations typically by factors of 2-3 on timescales of years. We found that the variability st...

  20. A Soft X-ray Polarimeter Designed for Broad-band X-ray Telescopes

    OpenAIRE

    Marshall, Herman L.

    2007-01-01

    A novel approach for measuring linear X-ray polarization over a broad-band using conventional imaging optics and cameras is described. A new type of high efficiency grating, called the critical angle transmission grating is used to disperse soft X-rays radially from the telescope axis. A set of multilayer-coated paraboloids re-image the dispersed X-rays to rings in the focal plane. The intensity variation around these rings is measured to determine three Stokes parameters: I, Q, and U. By lat...

  1. Femtosecond X-ray Absorption Spectroscopy at a Hard X-ray Free Electron Laser

    DEFF Research Database (Denmark)

    Lemke, Henrik T.; Bressler, Christian; Chen, Lin X.;

    2013-01-01

    X-ray free electron lasers (XFELs) deliver short (time-resolved studies. Here we show that, despite the inherent instabilities of current (SASE based) XFELs, they can be used for measuring high......-quality X-ray absorption data and we report femtosecond time-resolved X-ray absorption near-edge spectroscopy (XANES) measurements of a spin-crossover system, iron(II) tris(2,2'-bipyridine) in water. The data indicate that the low-spin to high-spin transition can be modeled by single-exponential kinetics...

  2. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  3. Some observational aspects of compact galactic X-ray sources

    International Nuclear Information System (INIS)

    This thesis contains the following observations of compact galactic X-ray sources: i) the X-ray experiments onboard the Astronomical Netherlands Satellite ANS, ii) a rocket-borne ultra soft X-ray experiment and iii) the Objective Grating Spectrometer onboard the EINSTEIN observatory. In Chapter I the various types of compact galactic X-ray sources are reviewed and put into the perspective of earlier and following observations. In Chapter II the author presents some of the observations of high luminosity X-ray sources, made with ANS, including the detection of soft X-rays from the compact X-ray binary Hercules X-1 and the ''return to the high state'' of the black hole candidate Cygnus X-1. Chapter III deals with transient X-ray phenomena. Results on low luminosity galactic X-ray sources are collected in Chapter IV. (Auth.)

  4. Calculation of x-ray scattering patterns from nanocrystals at high x-ray intensity.

    Science.gov (United States)

    Abdullah, Malik Muhammad; Jurek, Zoltan; Son, Sang-Kil; Santra, Robin

    2016-09-01

    We present a generalized method to describe the x-ray scattering intensity of the Bragg spots in a diffraction pattern from nanocrystals exposed to intense x-ray pulses. Our method involves the subdivision of a crystal into smaller units. In order to calculate the dynamics within every unit, we employ a Monte-Carlo-molecular dynamics-ab-initio hybrid framework using real space periodic boundary conditions. By combining all the units, we simulate the diffraction pattern of a crystal larger than the transverse x-ray beam profile, a situation commonly encountered in femtosecond nanocrystallography experiments with focused x-ray free-electron laser radiation. Radiation damage is not spatially uniform and depends on the fluence associated with each specific region inside the crystal. To investigate the effects of uniform and non-uniform fluence distribution, we have used two different spatial beam profiles, Gaussian and flattop. PMID:27478859

  5. Laser-based X-ray and electron source for X-ray fluorescence studies

    CERN Document Server

    Brozas, F Valle; Roso, L; Conde, A Peralta

    2016-01-01

    In this work we present a modification to conventional X-rays fluorescence using electrons as excitation source, and compare it with the traditional X-ray excitation for the study of pigments. For this purpose we have constructed a laser-based source capable to produce X-rays as well as electrons. Because of the large penetration depth of X-rays, the collected fluorescence signal is a combination of several material layers of the artwork under study. However electrons are stopped in the first layers allowing therefore a more superficial analysis. We show that the combination of both excitation sources can provide extremely valuable information about the structure of the artwork.

  6. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan;

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...... in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all...

  7. Soft X-ray Absorbers Enabling Study of the Diffuse X-ray Background Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Absorbers for soft x-rays need to be made thinner and with larger area, to collect more photons, and with minimal number of support stems. However, the structure is...

  8. Calculation of x-ray scattering patterns from nanocrystals at high x-ray intensity

    CERN Document Server

    Abdullah, Malik Muhammad; Son, Sang-Kil; Santra, Robin

    2016-01-01

    We present a generalized method to describe the x-ray scattering intensity of the Bragg spots in a diffraction pattern from nanocrystals exposed to intense x-ray pulses. Our method involves the subdivision of a crystal into smaller units. In order to calculate the dynamics within every unit we employ a Monte-Carlo (MC)-molecular dynamics (MD)-ab-initio hybrid framework using real space periodic boundary conditions. By combining all the units we simulate the diffraction pattern of a crystal larger than the transverse x-ray beam profile, a situation commonly encountered in femtosecond nanocrystallography experiments with focused x-ray free-electron laser radiation. Radiation damage is not spatially uniform and depends on the fluence associated with each specific region inside the crystal. To investigate the effects of uniform and non-uniform fluence distribution we have used two different spatial beam profiles, gaussian and flattop.

  9. Hard X-Ray, Soft X-Ray, and EUV Studies of Solar Eruptions

    Science.gov (United States)

    Sterling, Alphonse C.; Wagner, William (Technical Monitor)

    2003-01-01

    Document study the hard X-ray (HXR), soft X-ray (SXR) ,EUV, and magnetic nature of solar eruptions, with the objective of elucidating the physics of the eruption process. In particular, it was examine the viability of two specific eruption mechanisms, detailed in our proposal. These mechanisms are the "breakout model", and the "tether cutting model". During the second year, it was a significant progress in the goals to Data Sets Utilized. In the publications during this second year of the grant period, the data was used from the E W Imaging Telescope (EIT) and the Michelson Doppler Imager (MDI) instruments on SOHO, and from the Soft X-ray Telescope (SXT), Hard X-ray Telescope (HXT), and the Bragg Crystal Spectrometer (BCS) on Yooh.

  10. Monolithic CMOS imaging x-ray spectrometers

    Science.gov (United States)

    Kenter, Almus; Kraft, Ralph; Gauron, Thomas; Murray, Stephen S.

    2014-07-01

    The Smithsonian Astrophysical Observatory (SAO) in collaboration with SRI/Sarnoff is developing monolithic CMOS detectors optimized for x-ray astronomy. The goal of this multi-year program is to produce CMOS x-ray imaging spectrometers that are Fano noise limited over the 0.1-10keV energy band while incorporating the many benefits of CMOS technology. These benefits include: low power consumption, radiation "hardness", high levels of integration, and very high read rates. Small format test devices from a previous wafer fabrication run (2011-2012) have recently been back-thinned and tested for response below 1keV. These devices perform as expected in regards to dark current, read noise, spectral response and Quantum Efficiency (QE). We demonstrate that running these devices at rates ~> 1Mpix/second eliminates the need for cooling as shot noise from any dark current is greatly mitigated. The test devices were fabricated on 15μm, high resistivity custom (~30kΩ-cm) epitaxial silicon and have a 16 by 192 pixel format. They incorporate 16μm pitch, 6 Transistor Pinned Photo Diode (6TPPD) pixels which have ~40μV/electron sensitivity and a highly parallel analog CDS signal chain. Newer, improved, lower noise detectors have just been fabricated (October 2013). These new detectors are fabricated on 9μm epitaxial silicon and have a 1k by 1k format. They incorporate similar 16μm pitch, 6TPPD pixels but have ~ 50% higher sensitivity and much (3×) lower read noise. These new detectors have undergone preliminary testing for functionality in Front Illuminated (FI) form and are presently being prepared for back thinning and packaging. Monolithic CMOS devices such as these, would be ideal candidate detectors for the focal planes of Solar, planetary and other space-borne x-ray astronomy missions. The high through-put, low noise and excellent low energy response, provide high dynamic range and good time resolution; bright, time varying x-ray features could be temporally and

  11. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  12. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  13. The ITER core imaging x-ray spectrometer: x-ray calorimeter performance.

    Science.gov (United States)

    Beiersdorfer, P; Brown, G V; Clementson, J; Dunn, J; Morris, K; Wang, E; Kelley, R L; Kilbourne, C A; Porter, F S; Bitter, M; Feder, R; Hill, K W; Johnson, D; Barnsley, R

    2010-10-01

    We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

  14. The ITER core imaging x-ray spectrometer: X-ray calorimeter performance

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.; Brown, G. V.; Clementson, J.; Dunn, J.; Morris, K.; Wang, E. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Kelley, R. L.; Kilbourne, C. A.; Porter, F. S. [NASA Goddard Space Flight Center, Greenbelt, Maryland 20771 (United States); Bitter, M.; Feder, R.; Hill, K. W.; Johnson, D. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Barnsley, R. [ITER Cadarache JWS, Cadarache Centre, 13108 St Paul-Les-Durance (France)

    2010-10-15

    We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

  15. The ITER core imaging x-ray spectrometer: X-ray calorimeter performance

    International Nuclear Information System (INIS)

    We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

  16. On the X-ray Spectra of Anomalous X-ray Pulsars and Soft Gamma Repeaters

    OpenAIRE

    Kaspi, Victoria M.; Boydstun, Kristen

    2010-01-01

    We revisit the apparent correlation between soft X-ray band photon index and spin-down rate ύ previously reported for Anomalous X-ray Pulsars (AXPs) and Soft Gamma Repeaters (SGRs) by Marsden & White. Our analysis, improved thanks to new source discoveries, better spectral parameter measurements in previously known sources, and the requirement of source quiescence for parameter inclusion, shows evidence for the previously noted trend, although with greater scatter. This trend supp...

  17. A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

    CERN Document Server

    Li, Hong; Ji, Jianfeng; Deng, Zhi; He, Li; Zeng, Ming; Li, Tenglin; Liu, Yinong; Heng, Peiyin; Wu, Qiong; Han, Dong; Dong, Yongwei; Lu, Fangjun; Zhang, Shuangnan

    2015-01-01

    The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.

  18. Magnetar-like X-ray bursts from an anomalous X-ray pulsar.

    Science.gov (United States)

    Gavriil, F P; Kaspi, V M; Woods, P M

    2002-09-12

    Anomalous X-ray pulsars (AXPs) are a class of rare X-ray emitting pulsars whose energy source has been perplexing for some 20 years. Unlike other X-ray emitting pulsars, AXPs cannot be powered by rotational energy or by accretion of matter from a binary companion star, hence the designation 'anomalous'. Many of the rotational and radiative properties of the AXPs are strikingly similar to those of another class of exotic objects, the soft-gamma-ray repeaters (SGRs). But the defining property of the SGRs--their low-energy-gamma-ray and X-ray bursts--has not hitherto been observed for AXPs. Soft-gamma-ray repeaters are thought to be 'magnetars', which are young neutron stars whose emission is powered by the decay of an ultra-high magnetic field; the suggestion that AXPs might also be magnetars has been controversial. Here we report two X-ray bursts, with properties similar to those of SGRs, from the direction of the anomalous X-ray pulsar 1E1048.1 - 5937. These events imply a close relationship (perhaps evolutionary) between AXPs and SGRs, with both being magnetars.

  19. HERMES: a soft X-ray beamline dedicated to X-ray microscopy.

    Science.gov (United States)

    Belkhou, Rachid; Stanescu, Stefan; Swaraj, Sufal; Besson, Adrien; Ledoux, Milena; Hajlaoui, Mahdi; Dalle, Didier

    2015-07-01

    The HERMES beamline (High Efficiency and Resolution beamline dedicated to X-ray Microscopy and Electron Spectroscopy), built at Synchrotron SOLEIL (Saint-Auban, France), is dedicated to soft X-ray microscopy. The beamline combines two complementary microscopy methods: XPEEM (X-ray Photo Emitted Electron Microscopy) and STXM (Scanning Transmission X-ray Microscopy) with an aim to reach spatial resolution below 20 nm and to fully exploit the local spectroscopic capabilities of the two microscopes. The availability of the two methods within the same beamline enables the users to select the appropriate approach to study their specific case in terms of sample environment, spectroscopy methods, probing depth etc. In this paper a general description of the beamline and its design are presented. The performance and specifications of the beamline will be reviewed in detail. Moreover, the article is aiming to demonstrate how the beamline performances have been specifically optimized to fulfill the specific requirements of a soft X-ray microscopy beamline in terms of flux, resolution, beam size etc. Special attention has been dedicated to overcome some limiting and hindering problems that are usually encountered on soft X-ray beamlines such as carbon contamination, thermal stability and spectral purity. PMID:26134801

  20. First Terrestrial Soft X-Ray Auroral Observation by the Chandra X-Ray Observatory

    Science.gov (United States)

    Bhardwaj, Anil; Gladstone, G. Randall; Elsner, Ronald F.; Oestgaard, Nikolai; Waite, J. Hunter, Jr.; Cravens, Thomas E.; Chang, Shen-Wu; Majeed, Tariq; Metzger, Albert E.

    2007-01-01

    Northern auroral regions of Earth were imaged with energetic photons in the 0.1-10keV range using the High-Resolution Camera (HRC-I) aboard the Chandra X-ray Observatory at 10 epochs (each approx.20 min duration) between mid- December 2003 and mid-April 2004. These observations aimed at searching for Earth's soft (X-ray aurora in a comparative study with Jupiter's X-ray aurora, where a pulsating X-ray "hot-spot" has been previously observed by Chandra. The first Chandra soft X-ray observations of Earth's aurora show that it is highly variable 0ntense arcs, multiple arcs, diffuse patches, at times absent). In at least one of the observations an isolated blob of emission is observed near the expected cusp location. A fortuitous overflight of DMSP satellite F13 provided SSJ/4 energetic particle measurements above a bright arc seen by Chandra on 24 January 2004, 20:01-20:22 UT. A model of the emissions expected strongly suggests that the observed soft X-ray signal is bremsstrahlung and characteristic K-shell line emissions of nitrogen and oxygen in the atmosphere produced by electrons.

  1. HERMES: a soft X-ray beamline dedicated to X-ray microscopy.

    Science.gov (United States)

    Belkhou, Rachid; Stanescu, Stefan; Swaraj, Sufal; Besson, Adrien; Ledoux, Milena; Hajlaoui, Mahdi; Dalle, Didier

    2015-07-01

    The HERMES beamline (High Efficiency and Resolution beamline dedicated to X-ray Microscopy and Electron Spectroscopy), built at Synchrotron SOLEIL (Saint-Auban, France), is dedicated to soft X-ray microscopy. The beamline combines two complementary microscopy methods: XPEEM (X-ray Photo Emitted Electron Microscopy) and STXM (Scanning Transmission X-ray Microscopy) with an aim to reach spatial resolution below 20 nm and to fully exploit the local spectroscopic capabilities of the two microscopes. The availability of the two methods within the same beamline enables the users to select the appropriate approach to study their specific case in terms of sample environment, spectroscopy methods, probing depth etc. In this paper a general description of the beamline and its design are presented. The performance and specifications of the beamline will be reviewed in detail. Moreover, the article is aiming to demonstrate how the beamline performances have been specifically optimized to fulfill the specific requirements of a soft X-ray microscopy beamline in terms of flux, resolution, beam size etc. Special attention has been dedicated to overcome some limiting and hindering problems that are usually encountered on soft X-ray beamlines such as carbon contamination, thermal stability and spectral purity.

  2. X-ray bursts observed with JEM-X

    DEFF Research Database (Denmark)

    Brandt, Søren Kristian; Chenevez, Jérôme; Lund, Niels;

    2006-01-01

    We report on the search for X-ray bursts in the JEM-X X-ray monitor on INTEGRAL during the first two years of operations. More than 350 bursts from 25 different type-I X-ray burst sources were found.......We report on the search for X-ray bursts in the JEM-X X-ray monitor on INTEGRAL during the first two years of operations. More than 350 bursts from 25 different type-I X-ray burst sources were found....

  3. Flywheel-powered X-ray generator

    Science.gov (United States)

    Siedband, M. P.

    1984-01-01

    The use of a small flywheel appears to be a practical alternative to other power sources for mobile X-ray system applications. A 5 kg flywheel has been constructed which runs at 10 krpm and stores 30 KJ while requiring less than 500 W to bring the system up to speed. The wheel is coupled to an aircraft alternator and can yield pulsed power levels over 50 KWp. The aircraft alternator has the advantage of high frequency output which has also permitted the design of smaller high voltage transformers. A series of optical sensors detecting shaft position function as an electronic commutator so that the alternator may operate as a motor to bring the wheel up to operating speed. The system permits the generation of extremely powerful X-rays from a variety of low power sources such as household power outlets, automobile batteries or sources of poorly regulated electrical power such as those found in third world countries.

  4. Early days of X-ray crystallography

    CERN Document Server

    Authier, André

    2013-01-01

    This book relates the discovery itself, the early days of X-ray crystallography, and the way the news of the discovery spread round the world. It explains how the first crystal structures were determined, and recounts which were the early applications of X-ray crystallography. It also tells how the concept of space lattice has developed since ancient times, and how our understanding of the nature of light has changed over time. The contributions of the main actors of the story, prior to the discovery, at the time of the discovery and immediately afterwards, are described through their writings and are put into the context of the time, accompanied by brief biographical details.

  5. Material analysis with X-ray microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Friedel, F.; Winkler, U.; Holtz, B. [ThyssenKrupp Stahl AG, Duisburg (Germany); Seyrich, R.; Ullrich, H.J. [Dresden University of Technology (Germany)

    2005-01-01

    Steel has continued to develop its status as a lightweight construction material for the design of vehicle bodies, most recently with the development of multi-phase steel. With a specific mixture of different phases in the steel microstructure, multi-phase steel combines high stability with good forming capacity. The characterisation of the complex structure of the multi-phase steel represents a challenge for metallurgists. For some years a new generation of X-ray diffractometers with two-dimensional (area) detectors and apparatus for local dissolved measurements are available to customers. This paper reports the applications and advantages of the modern X-ray diffractometry method. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. X-ray energy dispersive diffraction

    International Nuclear Information System (INIS)

    X-ray energy dispersive diffraction is used mainly for structural characterization of polycrystalline powders and amorphous materials. One of the important features of it is the fixed scattering angle facilitating in particular studies of materials in special environments (e.g., high pressure, high and low temperature). There are two versions of X-ray energy dispersive diffraction. In one - called XED - an incident 'white' beam is used and the spectral distribution of the diffracted photons is analyzed by means of a solid state detector. Its important feature is the simultaneous appearance of all reflections. In the other version - called monochromator scan method (MSM) - the incident beam is monochromatic and its wavelength is changed stepwise by rotating the crystal monochromator. (orig.)

  7. Observation of extragalactic X-ray sources

    International Nuclear Information System (INIS)

    A narrow angular resolution detection apparatus using a high performance collimator has proved particularly well suited for the programs of observation of X ray sources. The experimental set-up and its performance are described. One chapter deals with the particular problems involved in the observation of X ray sources with the aid of sounding balloons. The absorption of extraterrestrial photons by the earth atmosphere is taken into account in the procesing of the observation data using two methods of calculation: digital and with simulation techniques. The results of three balloon flights are then presented with the interpretation of the observations carried out using both thermal and non thermal emission models. This analysis leads to some possible characteristics of structure of the Perseus galaxy cluster

  8. Soft X-ray Polarimetry Development

    Science.gov (United States)

    Marshall, Herman; Schulz, Norbert S.; Heine, Sarah

    2016-07-01

    We present continued development of a telescope for measuring linear X-ray polarization over the 0.2-0.8 keV band. We employ multilayer-coated mirrors as Bragg reflectors at the Brewster angle. By matching to the dispersion of a spectrometer, one may take advantage of high multilayer reflectivities and achieve polarization modulation factors over 95%. We have constructed a source of polarized X-rays that operates at a wide range of energies with a selectable polarization angle. We will present results from measurements of new laterally graded multilayer mirrors and new gratings essential to the design. Finally, we will present a design for a small telescope for suborbital or orbital missions. A suborbital mission could measure the polarization of a blazar such as Mk 421 to 5-10 percent while an orbital version could measure the polarizations of neutron stars, active galactic nuclei, and blazars.

  9. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs

  10. Burst Detector X-Ray IIR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The Burst Detector X-Ray (BDX) instrument for the Block IIR series of Global Positioning System satellites is described. The BDX instrument can locate and characterize exoatmospheric nuclear detonations by using four sensors consisting of sets of filters over silicon diodes to detect x rays of various energies from the burst. On the BDX-IIR, a fifth sensor with a response spanning those of the other sensors confirms coincidences among the four main channels. The mechanical and electronic features of the BDX-IIR and its sensors are described. The calibrations and the system tests used in flight are presented. The commands for the BDX-IIR are given. The messages sent from the BDX-IIR are described in detail.

  11. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  12. X-ray characterisation of nanostructured materials

    DEFF Research Database (Denmark)

    Oddershede, Jette

    X-ray powder di®raction (XRPD) is an excellent tool for characterising the bulk structure of crystalline materials. Along with the growing interest in exploiting materials with decreasing particle sizes and increasing number of defects, factors that complicate the traditional interpretation...... of the experi- mental XRPD patterns, the need for new interpretation methods has arisen. The method described in the present thesis is by no means new, in fact it was developed by Debye in 1915. However, the Debye method it is rather computationally heavy, so in practise it is only applicable to the X-ray char...... Information File (CIF), simulate the XRPD pattern given information about the nature of the sample and the experimental setup, and ¯nally ¯t the simulated di®ractogram to experimental XRPD data. Three very di®erent materials were studied using the Debye approach: 1) Cellulose, an organic polymer with a nano...

  13. Soft X-ray multilayers and filters

    CERN Document Server

    Wang Zhan Shan; Tang Wei Xing; Qin Shuji; Zhou Bing; Chen Ling Ya

    2002-01-01

    The periodic and non-periodic multilayers were designed by using a random number to change each layer and a suitable merit function. Ion beam sputtering and magnetron sputtering were used to fabricate various multilayers and beam splitters in soft X-ray range. The characterization of multilayers by small angle X-ray diffraction, Auger electron spectroscopy, Rutherford back scattering spectroscopy and reflectivity illustrated the multilayers had good structures and smooth interlayers. The reflectivity and transmission of a beam splitter is about 5%. The fabrication and transmission properties of Ag, Zr were studied. The Rutherford back scattering spectroscopy and auger electron spectroscopy were used to investigate the contents and distributions of impurities and influence on qualities of filters. The attenuation coefficients were corrected by the data obtained by measurements

  14. How x rays inhibit amphibian limb regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Maden, M.; Wallace, H.

    1976-07-01

    The effects of an inhibiting dose of 2,000 rad of x-rays on the regenerating limbs of axolotl larvae have been examined in a histological and cytological study. Particular attention was paid to the mitotic indices of normal and irradiated epidermal and blastemal cells. Both the characteristic pattern of epidermal mitotic stimulation which normally follows amputation and the later increase in blastemal mitoses are suppressed by irradiation. In most cells the effects are permanent, but in a small proportion a mitotic delay is induced and upon subsequent division chromosome damage in the form of micronuclei is revealed. Thus irradiated cells which do divide almost certainly die. These results are discussed in relation to other theories of x-ray inhibition of regeneration with particular reference to the view that irradiated cells can be reactivated.

  15. Beyond Chandra - the X-ray Surveyor

    CERN Document Server

    Weisskopf, Martin C; Tananbaum, Harvey; Vikhlinin, Alexey

    2015-01-01

    Over the past 16 years, NASA's Chandra X-ray Observatory has provided an unparalleled means for exploring the universe with its half-arcsecond angular resolution. Chandra studies have deepened our understanding of galaxy clusters, active galactic nuclei, galaxies, supernova remnants, planets, and solar system objects addressing almost all areas of current interest in astronomy and astrophysics. As we look beyond Chandra, it is clear that comparable or even better angular resolution with greatly increased photon throughput is essential to address even more demanding science questions, such as the formation and subsequent growth of black hole seeds at very high redshift; the emergence of the first galaxy groups; and details of feedback over a large range of scales from galaxies to galaxy clusters. Recently, NASA Marshall Space Flight Center, together with the Smithsonian Astrophysical Observatory, has initiated a concept study for such a mission named the X-ray Surveyor. This study starts with a baseline payloa...

  16. X-ray safety in Ontario

    International Nuclear Information System (INIS)

    In July 1979 the Ontario Advisory Committee on Radiology was formed to develop a comprehensive strategy for x-ray safety in the province. At its hearings the committee recieved submissions from groups representing physicians, dentists, chiropractors, radiological technicians, physiotherapists, podiatrists, and consumers, among others; these briefs are included as appendices to the report. The report surveys the historical background and the current situation in Ontario, and makes recommendations for an organized safety program. (L.L.)

  17. POST TRAUMATIC KNEE FRACTURE ( X-RAY

    Directory of Open Access Journals (Sweden)

    Dr. Jalaja Prakash.

    2013-06-01

    Full Text Available A 51 year old male patient met with a road traffic accident on August 2010. On examination thepatient was unable to stand and walk. His right knee was swollen and complained of pain withinstability. The X-Ray of patient showed transverse fracture of patella along with comminutedfracture of lower end of femur. He was treated with “K” wire and internal fixation. The patient wasadvised early physiotherapy which include range of motion exercises, knee strengthening and gaittraining.

  18. Magnetic X-ray scattering from samarium

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.L. (School of Physics and Space Research, Univ. of Birmingham (United Kingdom)); Forgan, E.M. (School of Physics and Space Research, Univ. of Birmingham (United Kingdom)); Shaikh, S.J. (School of Physics and Space Research, Univ. of Birmingham (United Kingdom)); Tang, C.C. (Dept. of Physics, Univ. of Keele (United Kingdom)); Stirling, W.G. (Dept. of Physics, Univ. of Keele (United Kingdom)); Langridge, S. (Dept. of Physics, Univ. of Keele (United Kingdom)); Rollason, A.J. (Dept. of Physics, Univ. of Keele (United Kingdom)); Costa, M.M.R. (Physics Dept., Univ. de Coimbra (Portugal)); Cooper, M.J. (Dept. of Physics, Univ. of Warwick, Coventry (United Kingdom)); Zukowski, E. (Dept. of Physics, Univ. of Warwick, Coventry (United Kingdom)); Forsyth, J.B. (Dept. of Physics, Univ. of Warwick, Coventry (United Kingdom)); Fort, D. (School of Metallurgy and Materials, Univ. of Birmingham (United Kingdom))

    1993-10-01

    X-ray diffraction studies have been made of the antiferromagnetic ordering in the rare earth metal samarium, at the Synchrotron Radiation Source, Daresbury Laboratory. We have observed diffraction peaks which reflect the magnetic order on the hexagonal sites in the lattice and which are in agreement with previous neutron measurements. We have also observed the energy dependence of the resonant enhancement at both the L[sub III] and L[sub II] absorption edges of Sm. (orig.)

  19. Basic of X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Giacovazzo, C. [Bari Univ. (Italy). Dip. Geomineralogico

    1996-09-01

    The basic concepts of X-ray diffraction may be more easily understood if it is made preliminary use of a mathematical background. In these pages the authors will first define the delta function and its use for the representation of a lattice. Then the concepts of Fourier transform and convolution are given. At the end of this talk one should realize that a crystal is the convolution of the lattice with a function representing the content of the unit cell.

  20. Surface-Enhanced X-Ray Fluorescence

    Science.gov (United States)

    Anderson, Mark

    2010-01-01

    Surface-enhanced x-ray fluorescence (SEn-XRF) spectroscopy is a form of surface- enhanced spectroscopy that was conceived as a means of obtaining greater sensitivity in x-ray fluorescence (XRF) spectroscopy. As such, SEn-XRF spectroscopy joins the ranks of such other, longer-wavelength surface-enhanced spectroscopies as those based on surface-enhanced Raman scattering (SERS), surface-enhanced resonance Raman scattering (SERRS), and surfaceenhanced infrared Raman absorption (SEIRA), which have been described in previous NASA Tech Briefs articles. XRF spectroscopy has been used in analytical chemistry for determining the elemental compositions of small samples. XRF spectroscopy is rapid and quantitative and has been applied to a variety of metal and mineralogical samples. The main drawback of XRF spectroscopy as practiced heretofore is that sensitivity has not been as high as required for some applications. In SEn-XRF as in the other surface-enhanced spectroscopies, one exploits several interacting near-field phenomena, occurring on nanotextured surfaces, that give rise to local concentrations of incident far-field illumination. In this case, the far-field illumination comes from an x-ray source. Depending on the chemical composition and the geometry of a given nanotextured surface, these phenomena could include the lightning-rod effect (concentration of electric fields at the sharpest points on needlelike surface features), surface plasmon resonances, and grazing incidence geometric effects. In the far field, the observable effect of these phenomena is an increase in the intensity of the spectrum of interest - in this case, the x-ray fluorescence spectrum of chemical elements of interest that may be present within a surface layer at distances no more than a few nanometers from the surface.

  1. Large thin adaptive x-ray mirrors

    Science.gov (United States)

    Doel, Peter; Atkins, Carolyn; Thompson, Samantha; Brooks, David; Yao, Jun; Feldman, Charlotte; Willingale, Richard; Button, Tim; Zhang, Dou; James, Ady

    2007-09-01

    This paper describes the progress made in a proof of concept study and recent results of a research program into large active x-ray mirrors that is part of the UK Smart X-ray Optics project. The ultimate aim is to apply the techniques of active/adaptive optics to the next generation of nested shell astronomical X-ray space telescopes. A variety of deformable mirror technologies are currently available, the most promising of which for active X-ray mirrors are probably unimorph and bimorph piezoelectric mirrors. In this type of mirror one or more sheets of piezoelectric material are bonded to or coated with a passive reflective layer. On the back or between the piezoceramic layer/layers are series of electrodes. Application of an electric field causes the piezoelectric material to undergo local deformation thus changing the mirror shape. Starting in 2005 a proof of concept active mirror research program has been undertaken. This work included modelling and development of actively controlled thin shell mirrors. Finite element models of piezo-electric actuated mirrors have been developed and verified against experimental test systems. This has included the modelling and test of piezo-electric hexagonal unimorph segments. Various actuator types and low shrinkage conductive bonding methods have been investigated and laboratory tests of the use of piezo-electric actuators to adjust the form of an XMM-Newton space telescope engineering model mirror shell have been conducted and show that movement of the optics at the required level is achievable. Promising technological approaches have been identified including moulded piezo-ceramics and piezo-electrics fibre bundles.

  2. Installation of dental x-ray units

    International Nuclear Information System (INIS)

    The purpose of the x-ray units is to perform intra oral perapical and occlusal examinations. Radiation requirements include, 1.5mm A1 filtration tube (upto 70kv), focus film distance between 10cm and 20cm for 60kv or less, a field defining spacer cone with a diameter of 6cm beam on the film must be used, an apron (lead) to protect the patient, a long cable 1 metre long for operator

  3. TV X-ray flaw detector

    International Nuclear Information System (INIS)

    The aim of the invention is to ensure optimum operation of a TV x-ray flaw detector under transient non-destructive testing conditions. The operating conditions are optimized by using an electronic circuit compromizing series-connected line block extraction block, peak detector, differentiation block, zero member and control unit of radiation source voltage supply. The block diagram of the flaw detector is given, its operation principle is described

  4. X-ray Studies of Flaring Plasma

    Indian Academy of Sciences (India)

    B. Sylwester; J. Sylwester; K. J. H. Phillips

    2008-03-01

    We present some methods of X-ray data analysis employed in our laboratory for deducing the physical parameters of flaring plasma. For example, we have used a flare well observed with Polish instrument RESIK aboard Russian CORONAS-F satellite. Based on a careful instrument calibration, the absolute fluxes in a number of individual spectral lines have been obtained. The analysis of these lines allows us to follow the evolution of important thermodynamic parameters characterizing the emitting plasma throughout this flare evolution.

  5. Blazar microvariability at hard X-rays

    OpenAIRE

    Foschini, L.; Gliozzi, M.; Pian, E.; Tagliaferri, G.; Tavecchio, F.; Bianchin, V.; L. Maraschi(INAF National Institute for Astrophysics, I-00136 Rome, Italy); Sambruna, R. M.; Di Cocco, G.; Ghisellini, G.; Malaguti, G.; Tosti, G.; Treves, A.

    2007-01-01

    Blazars are known to display strong and erratic variability at almost all the wavelengths of electromagnetic spectrum. Presently, variability studies at high-energies (hard X-rays, gamma-rays) are hampered by low sensitivity of the instruments. Nevertheless, the latest generation of satellites (INTEGRAL, Swift) have given suggestions not yet fully confirmed of variability on intraday timescales. Some specific cases recently observed are presented and physical implications are discussed (e.g. ...

  6. The BMW X-ray Cluster Survey

    OpenAIRE

    Moretti, Alberto; Guzzo, Luigi; Campana, Sergio; Covino, Stefano; Lazzati, Davide; Longhetti, Marcella; Molinari, Emilio; Panzera, Maria Rosa; Tagliaferri, Gianpiero; Dell'Antonio, Ian

    2001-01-01

    We describe the main features of the BMW survey of serendipitous X-ray clusters, based on the still unexploited ROSAT-HRI archival observations. The sky coverage, surface density and first deep optical CCD images of the candidates indicate that this sample can represent an excellent complement to the existing PSPC deep cluster surveys and will provide us with a fully independent probe of the evolution of the cluster abundance, in addition to significantly increasing the number of clusters kno...

  7. Quality assurance in X-ray mammography

    International Nuclear Information System (INIS)

    Full text: Introduction: Breast Cancer (BC) is the most common cancer in the country, with a smooth upward trend. X-ray mammography is the gold standard in the diagnosis of breast cancer. The study was carried out with X-ray radiation with certain degree of risk of radiation carcinogenesis in a patient. There are international recommendations setting high requirements for the quality of mammography. What you will learn: In 2006 the fourth edition of the European recommendations for ensuring quality in screening and diagnosis of breast cancer was published. It stipulates the requirements to both technical and physical aspects of mammography screening and the quality of work of the radiologist, technologist, pathologist and surgeon. Some multidisciplinary aspects of quality assurance in the diagnostic process are discussed. Discussion: Some often neglected aspects in quality are discussed. A standard plexiglas phantom for each mammography system for daily tests holding of image quality and dose evaluation is necessary. In the dark room appropriate equipment for assessment of the developing process has be available, as often it is the main reason for the poor quality of the mammographic images. In digital mammography the conditions for mammograms reading - light and brightness of the room and equipment and monitor quality are neglected. Conclusion: One of the basic principles of radiation protection in diagnostic radiology required to obtain images with the necessary diagnostic information with minimal exposure to the patient. This is possible only in compliance with all aspects of quality assurance in X-ray mammography

  8. Saturated output tabletop X-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J.; Osterheld, A.L.; Nilsen, J.; Hunter, J.R. [Lawrence Livermore National Lab., CA (United States); Yuelin Li [Lawrence Livermore National Lab., CA (United States); ILSA, Lawrence Livermore National Lab., Livermore, CA (United States); Faenov, A.Ya.; Pikuz, T.A. [Lawrence Livermore National Lab., CA (United States); MISDC of VNIIFTRI, Mendeleevo (Russian Federation); Shlyaptsev, V.N. [Lawrence Livermore National Lab., CA (United States); DAS, Univ. of California Davis-Livermore, Livermore, CA (United States)

    2001-07-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion X-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (compact multipulse terawatt) laser system at the Lawrence livermore national laboratory (LLNL) have produced several X-ray lasers operating in the saturation regime. Output energy of 10-15 {mu}J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d{yields}4p transition at 147 A with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the X-ray laser output. (orig.)

  9. Saturated output tabletop x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J; Osterheld, A L; Nilsen, J; Hunter, J R; Li, Y; Faenov, A Ya; Pikuz, T A; Shlyaptsev, N

    2000-12-01

    The high efficiency method of transient collisional excitation has been successfully demonstrated for Ne-like and Ni-like ion x-ray laser schemes with small 5-10 J laser facilities. Our recent studies using the tabletop COMET (Compact Multipulse Terawatt) laser system at the Lawrence Livermore National Laboratory (LLNL) have produced several x-ray lasers operating in the saturation regime. Output energy of 10-15 {micro}J corresponding to a gL product of 18 has been achieved on the Ni-like Pd 4d {yields} 4p transition at 147 {angstrom} with a total energy of 5-7 J in a 600 ps pulse followed by a 1.2 ps pulse. Analysis of the laser beam angular profile indicates that refraction plays an important role in the amplification and propagation process in the plasma column. We report further improvement in the extraction efficiency by varying a number of laser driver parameters. In particular, the duration of the second short pulse producing the inversion has an observed effect on the x-ray laser output.

  10. AGN variability at hard X-rays

    CERN Document Server

    Soldi, S; Beckmann, V; Lubinski, P

    2010-01-01

    We present preliminary results on the variability properties of AGN above 20 keV in order to show the potential of the INTEGRAL IBIS/ISGRI and Swift/BAT instruments for hard X-ray timing analysis of AGN. The 15-50 keV light curves of 36 AGN observed by BAT during 5 years show significantly larger variations when the blazar population is considered (average normalized excess variance = 0.25) with respect to the Seyfert one (average normalized excess variance = 0.09). The hard X-ray luminosity is found to be anti-correlated to the variability amplitude in Seyfert galaxies and correlated to the black hole mass, confirming previous findings obtained with different AGN hard X-ray samples. We also present results on the Seyfert 1 galaxy IC 4329A, as an example of spectral variability study with INTEGRAL/ISGRI data. The position of the high-energy cut-off of this source is found to have varied during the INTEGRAL observations, pointing to a change of temperature of the Comptonising medium. For several bright Seyfert...

  11. A simulator for X-ray images

    International Nuclear Information System (INIS)

    A simulator for X-ray images is presented based on a virtual X-ray source and a virtual human body obtained from tomographic slices. In the simulator it is possible to modify the tube potential, the anodic current, the exposure time, the filtration and some geometric parameters such as source-skin distance, orientation and field size. The virtual body consists of a three-dimensional voxel matrix in which CT numbers for each point of the body are stored. The interactions of X rays passing through the body are evaluated using the pencil beam technique. The image is obtained by computing the dose absorbed by the detector and converting it into optical density using a proper response function. The image spatial resolution is limited by the voxel size. The influence of each parameter on the image quality can be observed interactively. The dose absorbed in each point of the body is an important parameter obtained as output of the simulator. (authors)

  12. X-Ray parameters of lumbar spine

    Directory of Open Access Journals (Sweden)

    Otabek Ablyazov

    2012-05-01

    Full Text Available Knowledge of anatomic spinal structures, especially its relation-ship to the functions performed, is necessary to form a correct diagnosis. The anatomical structure of the vertebrae varies de-pending on the level of the spinal segment. Normal anatomical parameters, derived from bone structures of the spine, are roughly determined by X-ray method.This paper presents the results of the survey radiography of the lumbar spine in a straight line and lateral projections in 30 individ-uals without pathology spine, aged 21-60 years with frequently observed lumbar spinal stenosis stenosis. Applying X-ray method there were studied shape, height, and the contours of the vertebral bodies and intervertebral disc in the front (interpedicular and sagittal planes; there were measured dimensions of the lumbar canal and foramen holes in the same planes. Using X-ray method can fully identify the bone parameters of vertebral column. How-ever, the informativity of the method depends on knowledge of radiologist about topographic anatomical features of spine.

  13. The X-ray Telescope of CAST

    CERN Document Server

    Kuster, M; Cebrián, S; Davenport, M; Elefteriadis, C; Englhauser, J; Fischer, H; Franz, J; Friedrich, P; Hartmann, R; Heinsius, F H; Hoffmann, Dieter H H; Hoffmeister, G; Joux, J N; Königsmann, K C; Kang, D; Kotthaus, R; Lasseur, C; Lippitsch, A; Lutz, G; Morales, J; Papaevangelou, T; Rodríguez, A; Strüder, L; Vogel, J; Zioutas, K

    2007-01-01

    The Cern Axion Solar Telescope (CAST) is in operation and taking data since 2003. The main objective of the CAST experiment is to search for a hypothetical pseudoscalar boson, the axion, which might be produced in the core of the sun. The basic physics process CAST is based on is the time inverted Primakoff effect, by which an axion can be converted into a detectable photon in an external electromagnetic field. The resulting X-ray photons are expected to be thermally distributed between 1 and 7 keV. The most sensitive detector system of CAST is a pn-CCD detector combined with a Wolter I type X-ray mirror system. With the X-ray telescope of CAST a background reduction of more than 2 orders off magnitude is achieved, such that for the first time the axion photon coupling constant g_agg can be probed beyond the best astrophysical constraints g_agg < 1 x 10^-10 GeV^-1.

  14. X-Ray Morphology,Kinematics and Geometry of the Eridanus Soft X-Ray Enhancement

    Science.gov (United States)

    Guo, Zhiyu; Burrows, David N.; Sanders, Wilton T.; Snowden, Steve L.; Penprase, Bryan E.

    1994-12-01

    We present mosaics of X-ray intensity maps and spectral fit results for selected regions of the Eridanus soft X-ray Enhancement (EXE), as well as kinematics of the X-ray absorbing clouds in the EXE region and geometrical properties of this X-ray emitting bubble. The work is based on pointed observations with the ROSAT Position Sensitive Proportional Counter, 21 cm observations with the NRAO 140 foot telescope at Green Bank and interstellar Na D line observations with the NOAO Coude Feed telescope at Kitt Peak. The ROSAT pointed observations examine two regions of the EXE. The first is an X-ray absorption lane produced by an IR filament which is located at galactic coordinates of about (199(deg) , -45(deg) ). The second is in the vicinity of the northern (galactic) boundary of the 1/4 keV EXE, at galactic coordinates of about (200(deg) , -25(deg) ). Both our spatial and spectral analysis suggest that variations in emission measure and NH are primarily reponsible for the observed variations of the X-ray intensity. Using 100mu intensities obtained from IRAS maps and NH column densities obtained from our X-ray spectral fits, we find 100 microns/NH ratios across the IR filament that are compatible with typical high latitude values. Maps of the X-ray absorbing clouds in the EXE region at 21 cm reveal that these clouds may belong to two different expanding systems, with one possibly associated with our Local Bubble and the other with the boundary of the EXE. Combination of 21 cm data with interstellar Na D line observations toward stars in the directions of some of the X-ray absorbing clouds along (l,b) ~ (200(deg) ,-40(deg) ) indicate that the near side of the EXE is farther than 151 pc and the distance to the center of the EXE at this latitude is about 226 pc. The density and the thermal pressure found for this X-ray emitting superbubble are 0.015 cm(-3) and 4.9 times 10(4) cm(-3) K.

  15. Projection-type X-ray microscope based on a spherical compound refractive X-ray lens

    OpenAIRE

    Dudchik, Yu. I.; Gary, C. K.; Park, H; Pantell, R H; Piestrup, M. A.

    2007-01-01

    New projection- type X-ray microscope with a compound refractive lens as the optical element is presented. The microscope consists of an X-ray source that is 1-2 mm in diameter, compound X-ray lens and X-ray camera that are placed in-line to satisfy the lens formula. The lens forms an image of the X-ray source at camera sensitive plate. An object is placed between the X-ray source and the lens as close as possible to the source, and the camera shows a shadow image of the object. Spatial resol...

  16. Achromatic X-ray lenses; Achromatische Roentgenlinsen

    Energy Technology Data Exchange (ETDEWEB)

    Umbach, Marion

    2009-07-01

    This thesis presents first results on the development of achromatic refractive X-ray lenses which can be used for scientific experiments at synchrotron sources. First of all the different requirements for achromatic X-ray lenses have been worked out. There are different types of lenses, one type can be used for monochromatized sources when the energy is scanned while the spot size should be constant. The other type can be used at beamlines providing a broad energy band. By a combination of focusing and defocusing elements we have developed a lens system that strongly reduces the chromatic aberration of a refractive lens in a given energy range. The great challenge in the X-ray case - in contrast to the visible range - the complex refractive index, which is very similar for the possible materials in the X-ray spectrum. For precise studies a numerical code has been developed, which calculates the different rays on their way through the lenses to the detector plane via raytracing. In this numerical code the intensity distribution in the detector plane has been analyzed for a chromatic and the corresponding achromatic system. By optimization routines for the two different fields of applications specific parameter combinations were found. For the experimental verification an achromatic system has been developed, consisting of biconcave SU-8 lenses and biconvex Nickel Fresnel lenses. Their fabrication was based on the LIGA-process, including a further innovative development, namely the fabrication of two different materials on one wafer. In the experiment at the synchrotron source ANKA the energy was varied in a specific energy range in steps of 0.1 keV. The intensity distribution for the different energies was detected at a certain focal length. For the achromatic system a reduction of the chromatic aberration could be clearly shown. Achromatic refractive X-ray lenses, especially for the use at synchrotron sources, have not been developed so far. As a consequence of the

  17. X-Ray Emission from the Soft X-Ray Transient Aquila X-1

    Science.gov (United States)

    Tavani, Marco

    1998-01-01

    Aquila X-1 is the most prolific of soft X-ray transients. It is believed to contain a rapidly spinning neutron star sporadically accreting near the Eddington limit from a low-mass companion star. The interest in studying the repeated X-ray outbursts from Aquila X-1 is twofold: (1) studying the relation between optical, soft and hard X-ray emission during the outburst onset, development and decay; (2) relating the spectral component to thermal and non-thermal processes occurring near the magnetosphere and in the boundary layer of a time-variable accretion disk. Our investigation is based on the BATSE monitoring of Aquila X-1 performed by our group. We observed Aquila X-1 in 1997 and re-analyzed archival information obtained in April 1994 during a period of extraordinary outbursting activity of the source in the hard X-ray range. Our results allow, for the first time for this important source, to obtain simultaneous spectral information from 2 keV to 200 keV. A black body (T = 0.8 keV) plus a broken power-law spectrum describe accurately the 1994 spectrum. Substantial hard X-ray emission is evident in the data, confirming that the accretion phase during sub-Eddington limit episodes is capable of producing energetic hard emission near 5 x 10(exp 35) ergs(exp -1). A preliminary paper summarizes our results, and a more comprehensive account is being written. We performed a theoretical analysis of possible emission mechanisms, and confirmed that a non-thermal emission mechanism triggered in a highly sheared magnetosphere at the accretion disk inner boundary can explain the hard X-ray emission. An anticorrelation between soft and hard X-ray emission is indeed prominently observed as predicted by this model.

  18. 21 CFR 892.1740 - Tomographic x-ray system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A tomographic x-ray system is an x-ray device intended to be used to produce radiologic images of a specific cross-sectional plane of the body by blurring or eliminating detail from other...

  19. Radiation Exposure in X-Ray and CT Examinations

    Science.gov (United States)

    ... A-Z Radiation Dose in X-Ray and CT Exams What are x-rays and what do ... natural background radiation for: ABDOMINAL REGION: Computed Tomography (CT)-Abdomen and Pelvis 10 mSv 3 years Computed ...

  20. Resonant X-ray emission with a standing wave excitation.

    Science.gov (United States)

    Ruotsalainen, Kari O; Honkanen, Ari-Pekka; Collins, Stephen P; Monaco, Giulio; Moretti Sala, Marco; Krisch, Michael; Hämäläinen, Keijo; Hakala, Mikko; Huotari, Simo

    2016-01-01

    The Borrmann effect is the anomalous transmission of x-rays in perfect crystals under diffraction conditions. It arises from the interference of the incident and diffracted waves, which creates a standing wave with nodes at strongly absorbing atoms. Dipolar absorption of x-rays is thus diminished, which makes the crystal nearly transparent for certain x-ray wave vectors. Indeed, a relative enhancement of electric quadrupole absorption via the Borrmann effect has been demonstrated recently. Here we show that the Borrmann effect has a significantly larger impact on resonant x-ray emission than is observable in x-ray absorption. Emission from a dipole forbidden intermediate state may even dominate the corresponding x-ray spectra. Our work extends the domain of x-ray standing wave methods to resonant x-ray emission spectroscopy and provides means for novel spectroscopic experiments in d- and f-electron systems.

  1. Resonant X-ray emission with a standing wave excitation

    Science.gov (United States)

    Ruotsalainen, Kari O.; Honkanen, Ari-Pekka; Collins, Stephen P.; Monaco, Giulio; Moretti Sala, Marco; Krisch, Michael; Hämäläinen, Keijo; Hakala, Mikko; Huotari, Simo

    2016-01-01

    The Borrmann effect is the anomalous transmission of x-rays in perfect crystals under diffraction conditions. It arises from the interference of the incident and diffracted waves, which creates a standing wave with nodes at strongly absorbing atoms. Dipolar absorption of x-rays is thus diminished, which makes the crystal nearly transparent for certain x-ray wave vectors. Indeed, a relative enhancement of electric quadrupole absorption via the Borrmann effect has been demonstrated recently. Here we show that the Borrmann effect has a significantly larger impact on resonant x-ray emission than is observable in x-ray absorption. Emission from a dipole forbidden intermediate state may even dominate the corresponding x-ray spectra. Our work extends the domain of x-ray standing wave methods to resonant x-ray emission spectroscopy and provides means for novel spectroscopic experiments in d- and f-electron systems. PMID:26935531

  2. Next Generation X-ray Polarimeter

    Science.gov (United States)

    Hill-Kittle, Joe

    The emission regions of many types of X-ray sources are small and cannot be spatially resolved without interferometry techniques that haven't yet been developed. In order to understand the emission mechanisms and emission geometry, alternate measurement techniques are required. Most microphysical processes that affect X-rays, including scattering and magnetic emission processes are imprinted as polarization signatures. X-ray polarization also reveals exotic physical processes occurring in regions of very strong gravitational and magnetic fields. Observations of X-ray polarization will provide a measurement of the geometrical distribution of gas and magnetic fields without foreground depolarization that affects longer wavelengths (e.g. Faraday rotation in the radio). Emission from accretion disks has an inclination-dependent polarization. The polarization signature is modified by extreme gravitational forces, which bend light, essentially changing the contribution of each part of the disk to the integrated total intensity seen by distant observers. Because gravity has the largest effect on the innermost parts of the disk (which are the hottest, and thus contributes to more high energy photons), the energy dependent polarization is diagnostic of disk inclination, black hole mass and spin. Increasing the sensitive energy band will make these measurements possible. X-ray polarimetry will also enable the study of the origin of cosmic rays in the universe, the nature of black holes, the role of black holes in the evolution of galaxies, and the interaction of matter with the highest physically possible magnetic fields. These objectives address NASA's strategic interest in the origin, structure, and evolution of the universe. We propose a two-year effort to develop the Next Generation X-ray Polarimeter (NGXP) that will have more than ten times the sensitivity of the current state of the art. NGXP will make possible game changing measurements of classes of astrophysical

  3. A new x-ray scatter reduction method based on frequency division multiplexing x-ray imaging technique

    Science.gov (United States)

    Zhang, J.; Chang, S.; Lu, J. P.; Zhou, O.

    2012-03-01

    X-ray scatter may significantly degrade imaging performance in x-ray radiography applications, including flatpanel detector-based x-ray imaging, tomosynthesis, and cone-beam CT (CBCT), primarily due to their large projection field sizes. It results in soft tissue contrast reduction, potentially severe image artifacts, and increased patient dose. Several different approaches have been developed to reject the scatter contributions, including analytical calculation, empirical algorithms, Monte-Carlo simulation, blocker based measurement, and slot scan technique. We recently developed a new x-ray scatter rejection method based on nanotechnology-enabled frequency division multiplexing x-ray (FDMX) imaging technique. The key enabling technology is the carbon nanotube (CNT)-based multi-beam field emission x-ray (MBFEX) source technology. The proposed FDMX imaging system has a MBFEX source with an array of x-ray tubes. The x-ray radiation from each individual x-ray tube is modulated at a certain given frequency. The collimated x-ray beams passed through the object and were captured by a high speed x-ray detector. A demultiplexing algorithm was applied to reject the scatter radiation from the primary radiation based on their different modulation frequencies. The x-ray images generated by the FDMX imaging technique clearly demonstrated improved imaging quality in terms of lower scatter-to-primary-ratio (SPR) and higher contrast-to-noise-ratio (CNR). It shows great potential of improving x-ray imaging performance and reducing patient dose.

  4. Physics and astronomy of celestial x-ray sources

    International Nuclear Information System (INIS)

    An introduction is given to those aspects of classical and atomic physics which are pertinent to x-ray astronomy, observations in the spectral band 1017 to 1021 Hz. The following discrete and extended x-ray sources are discussed: Scorpius X-1, Crab Nebula, Hercules X-1, Cygnus X-1, binary x-ray sources, other galactic sources and gamma-ray sources, extragalactic sources, the diffuse background, and soft x-ray background. 11 figures, 92 references

  5. Formation and evolution of X-ray binaries

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    We review recent progress in theoretical understanding of X-ray binaries,which has largely been driven by new observations.We select several topics including formation of compact low-mass X-ray binaries,the evolutionary connection between low-mass X-ray binaries and binary and millisecond radio pulsars,and ultraluminous X-ray sources,to illustrate the interplay between theories and observations.

  6. SZ/X-ray scaling relations using X-ray data and Planck Nominal maps

    Science.gov (United States)

    De Martino, I.; Atrio-Barandela, F.

    2016-09-01

    We determine the relation between the Comptonization parameter predicted using X-ray data YC, Xray and the X-ray luminosity LX, both magnitudes derived from ROSAT data, with the Comptonization parameter YC, SZ measured on Planck 2013 foreground cleaned Nominal maps. The 560 clusters of our sample includes clusters with masses M ≥ 1013 M⊙, one order of magnitude smaller than those used by the Planck Collaboration in a similar analysis. It also contains eight times more clusters in the redshift interval z ≤ 0.3. The prediction of the β = 2/3 model convolved with the Planck antenna beam agrees with the anisotropies measured in foreground cleaned Planck Nominal maps within the X-ray emitting region, confirming the results of an earlier analysis. The universal pressure profile overestimates the signal by a 15-21 per cent depending on the angular aperture. We show that the discrepancy is not due to the presence of cool-core systems but it is an indication of a brake in the LX - M relation towards low mass systems. We show that relation of the Comptonization parameter averaged over the region that emits 99 per cent of the X-ray flux and and the X-ray luminosity is consistent with the predictions of the self-similar model. We confirm previous findings that the scaling relations studied here do not evolve with redshift within the range probed by our catalogue.

  7. X-ray Properties of an Unbiased Hard X-ray Detected Sample of AGN

    Science.gov (United States)

    Winter, Lisa M.; Mushotzky, Richard F.; Tueller, Jack; Markwardt, Craig

    2007-01-01

    The SWIFT gamma ray observatory's Burst Alert Telescope (BAT) has detected a sample of active galactic nuclei (AGN) based solely on their hard X-ray flux (14-195keV). In this paper, we present for the first time XMM-Newton X-ray spectra for 22 BAT AGXs with no previously analyzed X-ray spectra. If our sources are a representative sample of the BAT AGN, as we claim, our results present for the first time global X-ray properties of an unbiased towards absorption (n(sub H) = 0.03), AGN sample. We find 9/22 low absorption (n(sub H) 2.0 keV. Five of the complex sources (NGC 612, ESO 362-G018, MRK 417, ESO 506-G027, and NGC 6860) are classified as Compton-thick candidates. Further, we find four more sources (SWIFT J0641.3+3257, SWIFT J0911.2+4533, SWIFT J1200.8+0650, and NGC 4992) with properties consistent with the hidden/buried AGN reported by Ueda et al. (2007). Finally, we include a comparison of the XMM EPIC spectra with available SWIFT X-ray Telescope (XRT) observations. From these comparisons, we find 6/16 sources with varying column densities, 6/16 sources with varying power law indices, and 13/16 sources with varying fluxes, over periods of hours to months. Flux and power law index are correlated for objects where both parameters vary.

  8. X-ray Polarization Probes of SNR and PWN

    Science.gov (United States)

    Romani, Roger W.

    2016-04-01

    X-ray synchrotron radiation traces the high energy extrema of e+/e- accelerated by pulsar magnetospheres and supernova shocks. X-ray polarization lets us probe the unresolved geometry of these relativistic shock structures. I summarize what we know about magnetic field geometries in these nebulae and the prospects for learning more from X-ray polarimetry.

  9. LLNL X-ray Calibration and Standards Laboratory

    International Nuclear Information System (INIS)

    The LLNL X-ray Calibration and Standards Laboratory is a unique facility for developing and calibrating x-ray sources, detectors, and materials, and for conducting x-ray physics research in support of our weapon and fusion-energy programs

  10. X-Rays: The Inside Story (Primary). Teacher's Guide.

    Science.gov (United States)

    Royal Australasian Coll. of Radiologists, Sydney (Australia).

    The goal of this unit is to help children explore the aspects of X-rays and radiology in society. Students develop an understanding that X-rays are silhouette images, beneficial in health care, and a part of radiology. The history and development of X-rays as well as their applications in advancing technology are also explored. The unit is…

  11. On the ultimate x-ray detector for angiography

    NARCIS (Netherlands)

    Slump, C.H.; Kauffman, J.A.; Flynn, M.J.

    2005-01-01

    The purpose of our research is to describe the ultimate X-ray detector for angiography. Angiography is a well established X-ray imaging technique for the examination of blood vessels. Contrast agent is injected followed by X-ray exposures and possible obstructions in the blood vessels can be visuali

  12. Establishing nonlinearity thresholds with ultraintense X-ray pulses.

    Science.gov (United States)

    Szlachetko, Jakub; Hoszowska, Joanna; Dousse, Jean-Claude; Nachtegaal, Maarten; Błachucki, Wojciech; Kayser, Yves; Sà, Jacinto; Messerschmidt, Marc; Boutet, Sebastien; Williams, Garth J; David, Christian; Smolentsev, Grigory; van Bokhoven, Jeroen A; Patterson, Bruce D; Penfold, Thomas J; Knopp, Gregor; Pajek, Marek; Abela, Rafael; Milne, Christopher J

    2016-09-13

    X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Herein we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state.

  13. X-ray generator for radiographs of seeds

    International Nuclear Information System (INIS)

    It is presented an X-ray generator which is destined to obtaining X-ray radiographs of seeds. It utilizes a low power X-ray tube with fine focal point. It consist of an electronic block and an irradiation chamber

  14. Femtosecond laser-electron x-ray source

    Science.gov (United States)

    Hartemann, Frederic V.; Baldis, Hector A.; Barty, Chris P.; Gibson, David J.; Rupp, Bernhard

    2004-04-20

    A femtosecond laser-electron X-ray source. A high-brightness relativistic electron injector produces an electron beam pulse train. A system accelerates the electron beam pulse train. The femtosecond laser-electron X-ray source includes a high intra-cavity power, mode-locked laser and an x-ray optics system.

  15. The X-ray bichromator - Theory and alignment

    Science.gov (United States)

    Hrdý, Jaromír; Hrdá, Jaromíra; Oberta, Peter

    2016-10-01

    The X-ray bichromator is a novel optical device introduced by the X-ray optics group of the Institute of Physics in a previous publication. The scope of this article is the detailed description of the adjustment possibilities of the X-ray bichromator.

  16. Establishing nonlinearity thresholds with ultraintense X-ray pulses.

    Science.gov (United States)

    Szlachetko, Jakub; Hoszowska, Joanna; Dousse, Jean-Claude; Nachtegaal, Maarten; Błachucki, Wojciech; Kayser, Yves; Sà, Jacinto; Messerschmidt, Marc; Boutet, Sebastien; Williams, Garth J; David, Christian; Smolentsev, Grigory; van Bokhoven, Jeroen A; Patterson, Bruce D; Penfold, Thomas J; Knopp, Gregor; Pajek, Marek; Abela, Rafael; Milne, Christopher J

    2016-01-01

    X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Herein we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state. PMID:27620067

  17. 21 CFR 892.1730 - Photofluorographic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Photofluorographic x-ray system. 892.1730 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1730 Photofluorographic x-ray system. (a) Identification. A photofluorographic x-ray system is a device that includes a fluoroscopic...

  18. Soft X-ray Emissions from Planets, Moons, and Comets

    CERN Document Server

    Bhardwaj, A I

    2002-01-01

    A wide variety of solar system bodies are now known to radiate in the soft x-ray energy (10 keV) x-rays result mainly from the electron bremsstrahlung process. In this paper we present a brief review of the x-ray observations on each of the planetary bodies and discuss their characteristics and proposed source mechanisms.

  19. Obscuring Supersoft X-ray Sources in Stellar Winds

    DEFF Research Database (Denmark)

    Nielsen, Mikkel Thomas Bøje; Dominik, Carsten; Nelemans, Gijs

    2011-01-01

    We investigate the possibility of obscuring supersoft X-ray sources in the winds of companion stars. We derive limits on the amount of circumstellar material needed to fully obscure a 'canonical' supersoft X-ray source in the Large Magellanic Cloud, as observed with the Chandra X-ray Observatory....

  20. 14th International Conference on X-Ray Lasers

    CERN Document Server

    Menoni, Carmen; Marconi, Mario

    2016-01-01

    These proceedings comprise invited and contributed papers presented at the 14th International Conference on X-Ray Lasers (ICXRL 2014). This conference is part of a continuing series dedicated to recent developments and applications of x-ray lasers and other coherent x-ray sources with attention to supporting technologies and instrumentation. New results in the generation of intense, coherent x-rays and progress toward practical devices and their applications in numerous fields are reported. Areas of research in plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generation, and other x-ray generation schemes are covered.  The scope of ICXRL 2014 included, but was not limited to: Laser-pumped X-ray lasers Discharge excitation and other X-ray laser pumping methods Injection/seeding of X-ray amplifiers New lasing transitions and novel X-ray laser schemes High Harmonic sources-Free-electron laser generation in the XUV and X-ray range Novel schemes for coherent XUV and X-ray ge...

  1. X-ray holographic microscopy: Improved images of zymogen granules

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Howells, M.; Kirz, J.; McQuaid, K.; Rothman, S.

    1988-10-01

    Soft x-ray holography has long been considered as a technique for x-ray microscopy. It has been only recently, however, that sub-micron resolution has been obtained in x-ray holography. This paper will concentrate on recent progress we have made in obtaining reconstructed images of improved quality. 15 refs., 6 figs.

  2. RXTE detects X-ray bursts from Circinus X-1

    NARCIS (Netherlands)

    Linares, M.; Soleri, P.; Watts, A.; Altamirano, D.; Armas-Padilla, M.; Cavecchi, Y.; Degenaar, N.; Kalamkar, M.; Kaur, R.; van der Klis, M.; Patruno, A.; Wijnands, R.; Yang, Y.; Casella, P.; Rea, N.

    2010-01-01

    After the recent report of X-ray re-brightening (ATel #2608), RXTE has observed the peculiar neutron star X-ray binary Cir X-1 eleven times during the last two weeks (May 11-25, 2010). We report the detection of nine X-ray bursts in RXTE-PCA data, 25 years after the first -and the only previous- det

  3. Radiation safety of children in X-ray examinations

    International Nuclear Information System (INIS)

    Problem of radiation safety of children in X-ray examinations is studied on the base of review of Soviet and foreign publications. Data on frequency of X-ray investigations and radiation loadings depending on sex and age of children are presented. Devices used in children X-ray examinations are decsribed. Recommendations on improving radiation safety of patients in pediatrics are given

  4. Broad-band hard X-ray reflectors

    DEFF Research Database (Denmark)

    Joensen, K.D.; Gorenstein, P.; Hoghoj, P.;

    1997-01-01

    Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of ...

  5. ``Soft X-ray transient'' outbursts which are not soft

    NARCIS (Netherlands)

    C. Brocksopp; R.M. Bandyopadhyay; R.P. Fender

    2004-01-01

    We have accumulated multiwavelength (X-ray, optical, radio) lightcurves for the eight black hole X-ray binaries which have been observed to enter a supposed `soft X-ray transient' outburst, but remained in the low/hard state throughout the outburst. Comparison of the lightcurve morphologies, spectra

  6. Establishing nonlinearity thresholds with ultraintense X-ray pulses

    Science.gov (United States)

    Szlachetko, Jakub; Hoszowska, Joanna; Dousse, Jean-Claude; Nachtegaal, Maarten; Błachucki, Wojciech; Kayser, Yves; Sà, Jacinto; Messerschmidt, Marc; Boutet, Sebastien; Williams, Garth J.; David, Christian; Smolentsev, Grigory; van Bokhoven, Jeroen A.; Patterson, Bruce D.; Penfold, Thomas J.; Knopp, Gregor; Pajek, Marek; Abela, Rafael; Milne, Christopher J.

    2016-09-01

    X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Herein we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state.

  7. X-Rays from Saturn and its Rings

    Science.gov (United States)

    Bhardwaj, Anil; Elsner, Ron F.; Waite, J. Hunter; Gladstone, G. Randall; Cravens, Tom E.; Ford, Peter G.

    2005-01-01

    In January 2004 Saturn was observed by Chandra ACIS-S in two exposures, 00:06 to 11:00 UT on 20 January and 14:32 UT on 26 January to 01:13 UT on 27 January. Each continuous observation lasted for about one full Saturn rotation. These observations detected an X-ray flare from the Saturn's disk and indicate that the entire Saturnian X-ray emission is highly variable -- a factor of $\\sim$4 variability in brightness in a week time. The Saturn X-ray flare has a time and magnitude matching feature with the solar X-ray flare, which suggests that the disk X-ray emission of Saturn is governed by processes happening on the Sun. These observations also unambiguously detected X-rays from Saturn's rings. The X-ray emissions from rings are present mainly in the 0.45-0.6 keV band centered on the atomic OK$\\alpha$ fluorescence line at 525 eV: indicating the production of X-rays due to oxygen atoms in the water icy rings. The characteristics of X-rays from Saturn's polar region appear to be statistically consistent with those from its disk X-rays, suggesting that X-ray emission from the polar cap region might be an extension of the Saturn disk X-ray emission.

  8. Obscuring Supersoft X-ray Sources in Stellar Winds

    OpenAIRE

    Nielsen, M.B.T.; Dominik, C.; Nelemans, G.A.

    2011-01-01

    We investigate the possibility of obscuring supersoft X-ray sources in the winds of companion stars. We derive limits on the amount of circumstellar material needed to fully obscure a ‘canonical’ supersoft X-ray source in the Large Magellanic Cloud, as observed with the Chandra X-ray Observatory.

  9. Bright X-ray galaxies in SDSS filaments

    OpenAIRE

    Tugay, A. V.

    2013-01-01

    Eighteen bright X-ray emitting galaxies were found in nearby filaments within SDSS region. Basic X-ray spectral parameters were estimated for these galaxies using power law model with photoelectric absorption. A close pair of X-ray galaxies was found.

  10. Focusing high-energy x-rays by a PMMA compound x-ray lens on Beijing synchrotron radiation facility

    Institute of Scientific and Technical Information of China (English)

    Le Zi-Chun; Liang Jing-Qiu; Dong Wen; Zhu Pei-Ping; Peng Liang-Qiang; Wang Wei-Biao; Huang Wan-Xia; Yuan Qing-Xi; Wang Jun-Yue

    2007-01-01

    The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays.

  11. Stig Sundell at the bent crystal X-ray spectrometer for the X-ray shift experiment.

    CERN Multimedia

    1976-01-01

    The bent crystal X-ray spectrometer is being used to measure small shifts in the frequencies of X-rays emitted from the lower electron energy levels, in order to learn about the size of the nuclei concerned

  12. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  13. Modeling and characterization of X-ray yield in a polychromatic, lab-scale, X-ray computed tomography system

    International Nuclear Information System (INIS)

    A modular X-ray computed micro-tomography (µXCT) system is characterized in terms of X-ray yield resulting both from the generated X-ray spectrum and from X-ray detection with an energy-sensitive detector. The X-ray computed tomography system is composed of a commercially available cone-beam microfocus X-ray source and a modular optically-coupled-CCD-scintillator X-ray detector. The X-ray yield is measured and reported in units independent from exposure time, X-ray tube beam target current, and cone-beam-to-detector geometry. The polychromatic X-ray source is modeled as a broad Bremsstrahlung X-ray spectrum in order to understand the effect of the controllable parameters, that is, X-ray tube accelerating voltage and X-ray beam filtering. An approach is adopted which expresses the absolute number of emitted X-rays. The response of the energy-sensitive detector to the modeled spectrum is modeled as a function of scintillator composition and thickness. The detection efficiency model for the polychromatic X-ray detector considers the response of the light collection system and the electronic imaging array in order to predict absolute count yield under the studied conditions. The modeling approach is applied to the specific hardware implemented in the current µXCT system. The model's predictions for absolute detection rate are in reasonable agreement with measured values under a range of conditions applied to the system for X-ray microtomography imaging, particularly for the LuAG:Ce scintillator material

  14. Modeling and characterization of X-ray yield in a polychromatic, lab-scale, X-ray computed tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Mertens, J.C.E.; Chawla, Nikhilesh, E-mail: nchawla@asu.edu

    2015-05-21

    A modular X-ray computed micro-tomography (µXCT) system is characterized in terms of X-ray yield resulting both from the generated X-ray spectrum and from X-ray detection with an energy-sensitive detector. The X-ray computed tomography system is composed of a commercially available cone-beam microfocus X-ray source and a modular optically-coupled-CCD-scintillator X-ray detector. The X-ray yield is measured and reported in units independent from exposure time, X-ray tube beam target current, and cone-beam-to-detector geometry. The polychromatic X-ray source is modeled as a broad Bremsstrahlung X-ray spectrum in order to understand the effect of the controllable parameters, that is, X-ray tube accelerating voltage and X-ray beam filtering. An approach is adopted which expresses the absolute number of emitted X-rays. The response of the energy-sensitive detector to the modeled spectrum is modeled as a function of scintillator composition and thickness. The detection efficiency model for the polychromatic X-ray detector considers the response of the light collection system and the electronic imaging array in order to predict absolute count yield under the studied conditions. The modeling approach is applied to the specific hardware implemented in the current µXCT system. The model's predictions for absolute detection rate are in reasonable agreement with measured values under a range of conditions applied to the system for X-ray microtomography imaging, particularly for the LuAG:Ce scintillator material.

  15. Material Discriminated X-Ray CT System by Using New X-Ray Imager with Energy Discriminate Function

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2008-04-01

    Full Text Available Material discriminated X-ray CT system has been constructed by using conventional X-ray tube (white X-ray source and photon-counting X-ray imager as an application with energy band detection. We have already reported material identify X-ray CT using K-shell edge method elsewhere. In this report the principle of material discrimination was adapted the separation of electron-density and atomic number from attenuation coefficient mapping in X-ray CT reconstructed image in two wavelength X-ray CT method using white X-ray source and energy discriminated X-ray imager by using two monochrome X-ray source method. The measurement phantom was prepared as four kinds material rods (Carbon(C, Iron(Fe, Copper(Cu, Titanium(Ti rods of 3mm-diameter inside an aluminum(Al rod of 20mm-diameter. We could observed material discriminated X-ray CT reconstructed image, however, the discrimination properties were not good than two monochrome X-ray CT method. This results was could be explained because X-ray scattering, beam-hardening and so on based on white X-ray source, which could not observe in two monochrome X-ray CT method. However, since our developed CdTe imager can be detect five energy-bands at the same time, we can use multi-band analysis to decrease the least square error margin. We will be able to obtain more high separation in atomic number mapping in X-ray CT reconstructed image by using this system.

  16. Absolute calibration of soft X-ray plates by using a self-calibrated X-ray bolometer

    International Nuclear Information System (INIS)

    The sensitivity of soft X-ray plates, Kodak 101-05 and ILFORD Q-PLATE at 1.1 keV was measured by using a self-calibrated X-ray bolometer as a standard detector for absolute measurements of soft X-rays. Cross-calibration was also made by using an X-ray sensitive diamond detector. Good agreement in the absolute sensitivity was obtained between the bolometer and the diamond detector. (author)

  17. X-ray Measurements of Black Hole X-ray Binary Source GRS 1915+105 and the Evolution of Hard X-ray Spectrum

    Indian Academy of Sciences (India)

    R. K. Manchanda

    2000-06-01

    We report the spectral measurement of GRS 1915+105 in the hard X-ray energy band of 20-140keV. The observations were made on March 30th, 1997 during a quiescent phase of the source. We discuss the mechanism of emission of hard X-ray photons and the evolution of the spectrum by comparing the data with earlier measurements and an axiomatic model for the X-ray source.

  18. Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Dongmei; Zhu, Shouping, E-mail: zhusp2009@gmail.com; Chen, Xueli; Chao, Tiantian; Cao, Xu; Zhao, Fengjun; Huang, Liyu; Liang, Jimin [Engineering Research Center of Molecular and Neuro Imaging of Ministry of Education and School of Life Science and Technology, Xidian University, Xi' an, Shaanxi 710071 (China)

    2014-11-10

    X-ray luminescence tomography (XLT) is an imaging technology based on X-ray-excitable materials. The main purpose of this paper is to obtain quantitative luminescence concentration using the structural information of the X-ray computed tomography (XCT) in the hybrid cone beam XLT/XCT system. A multi-wavelength luminescence cone beam XLT method with the structural a priori information is presented to relieve the severe ill-posedness problem in the cone beam XLT. The nanophosphors and phantom experiments were undertaken to access the linear relationship of the system response. Then, an in vivo mouse experiment was conducted. The in vivo experimental results show that the recovered concentration error as low as 6.67% with the location error of 0.85 mm can be achieved. The results demonstrate that the proposed method can accurately recover the nanophosphor inclusion and realize the quantitative imaging.

  19. X-ray fluorescence (XRF) set-up with a low power X-ray tube.

    Science.gov (United States)

    Gupta, Sheenu; Deep, Kanan; Jain, Lalita; Ansari, M A; Mittal, Vijay Kumar; Mittal, Raj

    2010-10-01

    The X-ray fluorescence set-up with a 100 W X-ray tube comprises a computer controlled system developed for remote operation and monitoring of tube and an adjustable stable 3D arrangement to procure variable excitation energies with low scattered background. The system was tested at different filament currents/anode voltages. The MDL of the set-up at 0.05-1.00 mA/4-12 kV is found approximately (1-100)ppm for K and L excitations and approximately (200-700)ppm for M excitations of elements and improves with filament current and anode voltage. Moreover, L measurements for Sm and Eu at five K X-ray energies of elements(Z=29-40) and analytical determination in some synthetic samples were undertaken. PMID:20570160

  20. X-ray fluorescence (XRF) set-up with a low power X-ray tube

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sheenu; Deep, Kanan [Nuclear Science Laboratories, Physics Department, Punjabi University, Patiala 147 002 (India); Jain, Lalita; Ansari, M.A. [Laser Electronic Support Section, Raja Ramanna Centre for Advanced Technology (RRCAT), Indore (India); Mittal, Vijay Kumar [Nuclear Science Laboratories, Physics Department, Punjabi University, Patiala 147 002 (India); Mittal, Raj, E-mail: rmsingla@yahoo.co [Nuclear Science Laboratories, Physics Department, Punjabi University, Patiala 147 002 (India)

    2010-10-15

    The X-ray fluorescence set-up with a 100 W X-ray tube comprises a computer controlled system developed for remote operation and monitoring of tube and an adjustable stable 3D arrangement to procure variable excitation energies with low scattered background. The system was tested at different filament currents/anode voltages. The MDL of the set-up at 0.05-1.00 mA/4-12 kV is found {approx}(1-100) ppm for K and L excitations and {approx}(200-700) ppm for M excitations of elements and improves with filament current and anode voltage. Moreover, L measurements for Sm and Eu at five K X-ray energies of elements(Z=29-40) and analytical determination in some synthetic samples were undertaken.

  1. X-ray framing camera for pulsed, high current, electron beam x-ray sources

    CERN Document Server

    Failor, B H; Riordan, j c; Lojewski, D Y

    2007-01-01

    High power x-ray sources built for nuclear weapons effects testing are evolving toward larger overall diameters and smaller anode cathode gaps. We describe a framing camera developed to measure the time-evolution of these 20-50 ns pulsed x-ray sources produced by currents in the 1.5-2.5 MA range and endpoint voltages between 0.2 and 1.5 MV. The camera has up to 4 frames with 5 ns gate widths; the frames are separated by 5 ns. The image data are recorded electronically with a gated intensified CCD camera and the data are available immediately following a shot. A fast plastic scintillator (2.1 ns decay time) converts the x-rays to visible light and, for high sensitivity, a fiber optic imaging bundle carries the light to the CCD input. Examples of image data are shown.

  2. A Soft X-ray Polarimeter Designed for Broad-band X-ray Telescopes

    CERN Document Server

    Marshall, Herman L

    2007-01-01

    A novel approach for measuring linear X-ray polarization over a broad-band using conventional imaging optics and cameras is described. A new type of high efficiency grating, called the critical angle transmission grating is used to disperse soft X-rays radially from the telescope axis. A set of multilayer-coated paraboloids re-image the dispersed X-rays to rings in the focal plane. The intensity variation around these rings is measured to determine three Stokes parameters: I, Q, and U. By laterally grading the multilayer optics and matching the dispersion of the gratings, one may take advantage of high multilayer reflectivities and achieve modulation factors over 50% over the entire 0.2 to 0.8 keV band. A sample design is shown that could be used with the Constellation-X optics.

  3. X-ray beam qualities for dental radiology purposes

    International Nuclear Information System (INIS)

    In order to establish characteristics or properties of equipment for diagnostic radiology, e.g. ion chambers and semiconductor detectors, calibration laboratories offer a set of well-defined radiation conditions, called X-ray qualities, which can be used for many Physics studies and medical purposes. The standardization of radiation qualities has been carried out in several fields of study, but little attention has been given to the area of dental radiology, mainly for medical and physical applications using single-phase units with half-wave rectification. For this reason, a single-phase dental unit with adjustable peak voltage and tube current, called 'variable potential X-ray equipment', was developed aiming to define X-ray beam qualities for test and calibrations purposes. X-ray spectra at 50, 60 and 70 kVp were determined by using a CdTe detector and compared with those obtained for ten commercial X-ray dental units. As a result of this study, a set of X-ray qualities for the variable potential X-ray equipment was determined. The X-ray qualities spectra were utilized as reference for determination of a new set of X-ray qualities characterized for a constant potential X-ray equipment. Thus, sets of X-ray qualities were standardized and implemented in two X-ray laboratories: one with the variable potential X-ray equipment and other with constant potential X-ray equipment. These reference X-ray beam qualities should be used for test and calibration purposes involving scientific studies and services. (author)

  4. The PERCIVAL soft X-ray imager

    Science.gov (United States)

    Wunderer, C. B.; Marras, A.; Bayer, M.; Correa, J.; Göttlicher, P.; Lange, S.; Shevyakov, I.; Smoljanin, S.; Tennert, M.; Viti, M.; Xia, Q.; Zimmer, M.; Das, D.; Guerrini, N.; Marsh, B.; Sedgwick, I.; Turchetta, R.; Cautero, G.; Gianoncelli, A.; Giuressi, D.; Menk, R.; Stebel, L.; Yousef, H.; Marchal, J.; Rees, N.; Tartoni, N.; Graafsma, H.

    2015-02-01

    With the increased brilliance of state-of-the-art Synchrotron radiation sources and the advent of Free Electron Lasers enabling revolutionary science on atomic length and time scales with EUV to X-ray photons comes an urgent need for suitable photon imaging detectors. Requirements include high frame rates, very large dynamic range, single-photon counting capability with low probability of false positives, and (multi)-megapixels. PERCIVAL (``Pixelated Energy Resolving CMOS Imager, Versatile And Large'') is currently being developed by a collaboration of DESY, RAL, Elettra, DLS and Pohang to address this need for the soft X-ray regime. PERCIVAL is a monolithic active pixel sensor (MAPS), i.e. based on CMOS technology. It will be back-thinned to access its primary energy range of 250 eV to 1 keV with target efficiencies above 90%. According to its preliminary specifications, the roughly 10 × 10 cm2, 3.5k × 3.7k monolithic ``PERCIVAL13M'' sensor will operate at frame rates up to 120 Hz (commensurate with most FELs) and use multiple gains within its 27 μm pixels to measure 1 to ~ 105 (500 eV) simultaneously-arriving photons. A smaller ``PERCIVAL2M'' with ~ 1.4k × 1.5k pixels is also planned. Currently, small-scale back-illuminated prototype systems (160 × 210 pixels of 25 μm pitch) are undergoing detailed testing with X-rays and optical photons. In March 2014, a prototype sensor was tested at 350 eV-2 keV at Elettra's TwinMic beamline. The data recorded include diffraction patterns at 350 eV and 400 eV, knife edge and sub-pixel pinhole illuminations, and comparisons of different pixel types. Another prototype chip will be submitted in fall 2014, first larger sensors could be in hand in late 2015.

  5. X-ray Cryogenic Facility (XRCF) Handbook

    Science.gov (United States)

    Kegley, Jeffrey R.

    2016-01-01

    The X-ray & Cryogenic Facility (XRCF) Handbook is a guide for planning operations at the facility. A summary of the capabilities, policies, and procedures is provided to enhance project coordination between the facility user and XRCF personnel. This handbook includes basic information that will enable the XRCF to effectively plan and support test activities. In addition, this handbook describes the facilities and systems available at the XRCF for supporting test operations. 1.2 General Facility Description The XRCF was built in 1989 to meet the stringent requirements associated with calibration of X-ray optics, instruments, and telescopes and was subsequently modified in 1999 & 2005 to perform the challenging cryogenic verification of Ultraviolet, Optical, and Infrared mirrors. These unique and premier specialty capabilities, coupled with its ability to meet multiple generic thermal vacuum test requirements for large payloads, make the XRCF the most versatile and adaptable space environmental test facility in the Agency. XRCF is also recognized as the newest, most cost effective, most highly utilized facility in the portfolio and as one of only five NASA facilities having unique capabilities. The XRCF is capable of supporting and has supported missions during all phases from technology development to flight verification. Programs/projects that have benefited from XRCF include Chandra, Solar X-ray Imager, Hinode, and James Webb Space Telescope. All test programs have been completed on-schedule and within budget and have experienced no delays due to facility readiness or failures. XRCF is currently supporting Strategic Astrophysics Technology Development for Cosmic Origins. Throughout the years, XRCF has partnered with and continues to maintain positive working relationships with organizations such as ATK, Ball Aerospace, Northrop Grumman Aerospace, Excelis (formerly Kodak/ITT), Smithsonian Astrophysical Observatory, Goddard Space Flight Center, University of Alabama

  6. Hard x-ray telescope mission

    DEFF Research Database (Denmark)

    Gorenstein, P.; Worrall, D.; Joensen, K.D.;

    1996-01-01

    The Hard X-Ray Telescope was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity...... and much better angular resolution in the 10 - 100 keV band, and (3) higher sensitivity for detecting gamma ray lines of known energy in the 100 keV to 1 MeV band. This paper emphasizes the mission aspects of the concept study such as the payload configuration and launch vehicle. An engineering team...

  7. X-ray haloes around supernova remnants

    International Nuclear Information System (INIS)

    Recent observations of the Cas-A supernova remnant have shown X-ray emissions not only from the interior, but also from a fainter 'halo' extending beyond what is normally regarded as the outer boundary, or shock front. The authors suggest that this may be due to the diffusion of energetic, charged particles out of the remnant giving rise to precursor structure of the type predicted by the theory of diffusive shock acceleration. If this is the case we are seeing thermal emission from ambient gas heated by compression and wave dissipation. (author)

  8. Aviation security x-ray detection challenges

    Science.gov (United States)

    Harvey, T.

    2016-05-01

    In this paper, a review of the background and some drivers are provided for X-ray screening for aviation security. Some of the key considerations are highlighted along with impacts of the image-based approaches and signature approaches. The role of information theory is discussed along with some recent work that may influence the technical direction by posing the question: "what measurements, parameters and metrics should be considered in future system design?" A path forward should be based on information theory, however electronic machines will likely interface with humans and be dollar-cost driven, so ultimately solutions must consider additional parameters other than only technical performance factors.

  9. Glancing angle synchrotron X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cernik, R.J. [Daresbury Lab., Warrington, WA (United States)

    1996-09-01

    This paper describes in basic detail some of the techniques that can be used to study thin films and surfaces. These are all in the X-ray region and cover reflectivity, diffraction form polycrystalline films, textured films and single crystal films. Other effects such as fluorescence and diffuse scattering are mentioned but not discussed in detail. Two examples of the reflectivity from multilayers and the diffraction from iron oxide films are discussed. The advantages of the synchrotron for these studies is stressed and the experimental geometries that can be employed are described i detail. A brief bibliography is provided at the end to accompany this part of the 1996 Frascati school.

  10. Phosphors for X-ray intensification screens

    International Nuclear Information System (INIS)

    An improved rare earth oxyhalide phosphor for x-ray intensification screens is described. The phosphors, of formula LnOX.T where Ln = La or Gd, X = Cl or Br and T = Tm or Tb, are mixed with a small amount of a trivalent antimony compound. The addition of antimony overcomes ageing due to attack by atmospheric moisture and renders the phosphor freeflowing so that dispersions can be readily made. Preferably the phosphor is washed with an aqueous solution of the antimony compound and the compound is the fluoride, chloride or butoxide, or potassium antimony tartrate. (U.K.)

  11. Elements of modern X-ray physics

    CERN Document Server

    Als-Nielsen, Jens

    2011-01-01

    Eagerly awaited, this second edition of a best-selling text comprehensively describes from a modern perspective the basics of x-ray physics as well as the completely new opportunities offered by synchrotron radiation. Written by internationally acclaimed authors, the style of the book is to develop the basic physical principles without obscuring them with excessive mathematics. The second edition differs substantially from the first edition, with over 30% new material, including: A new chapter on non-crystalline diffraction - designed to appeal to the large community wh

  12. X-RAY LASER RESEARCH AT PALAISEAU

    OpenAIRE

    Jaeglé, P.; Jamelot, G.; Carillon, A.; Klisnick, A.

    1986-01-01

    We present the soft X-ray laser experiments performed at Greco "Interaction Laser-Matière" (Palaiseau). They are mainly concerned with Lithium-like ions of aluminum in plasmas produced by 1.06 µ Nd-laser. We describe the experimental set-up which performs time-dependent gain measurements. We report results showing a gain-length product of 2 - 2.5 for the 3d - 5f line at 105.7 A . Comparison is made between experiment and computational model. The possible limiting role of radiation trapping fo...

  13. Wakefield Undulator For Generating X-rays

    CERN Document Server

    Opanasenko, A N

    2004-01-01

    Conception of wakefield undulator (WFU) with very short period is presented. In the base of photon generation by the WFU lies a new mechanism of undulator-type radiation emitted by an ultrarelativistic electron bunch that undulates due to non-synchronous spatial harmonics of its wakefields while the bunch moves along a periodic waveguide. The creation of the WFU with sub-millimeter periods due to advanced accelerator technology opens possibilities to generate hard X-rays employing relatively low electron energies without external alternative fields.

  14. Attosecond X-ray free electron laser

    Directory of Open Access Journals (Sweden)

    Kim D. E.

    2013-03-01

    Full Text Available For a real, meaningful pump-probe experiment with attosecond temporal resolution, an isolated attosecond pulse is in demand. In this vein we report the generation of an isolated ~ 148 attosecond pulse duration radiation pulse at 0.1 angstrom wavelength using current enhanced self-amplified spontaneous emission free electron laser. We consider the 10-GeV PAL-XFEL e-beam for enhanced self-amplified spontaneous emission (ESASE scheme. In ESASE, X-ray SASE FEL is combined with a femtosecond laser system. An 800 nm wavelength, 5 fs FWHM carrier envelope phase stabilized laser was employed in ESASE scheme.

  15. The X-ray Telescope of CAST

    OpenAIRE

    M. Kuster(Technische Universität Darmstadt); Bräuninger, H.; Cébrian, S.; Davenport, M.; Elefteriadis, C.; Englhauser, J.; Fischer, H.; Franz, J.; Friedrich, P.; Hartmann, R.; Heinsius, F. H.; Hoffmann, D H H; Hoffmeister, G.; Joux, J. N.; Kang, D.

    2007-01-01

    The Cern Axion Solar Telescope (CAST) is in operation and taking data since 2003. The main objective of the CAST experiment is to search for a hypothetical pseudoscalar boson, the axion, which might be produced in the core of the sun. The basic physics process CAST is based on is the time inverted Primakoff effect, by which an axion can be converted into a detectable photon in an external electromagnetic field. The resulting X-ray photons are expected to be thermally distributed between 1 and...

  16. The BMW X-ray Cluster Survey

    CERN Document Server

    Moretti, A; Campana, S; Covino, S; Lazzati, D; Longhetti, M; Molinari, E; Panzera, M R; Tagliaferri, G; Dell'Antonio, I P; Moretti, Alberto; Guzzo, Luigi; Campana, Sergio; Covino, Stefano; Lazzati, Davide; Longhetti, Marcella; Molinari, Emilio; Panzera, Maria Rosa; Tagliaferri, Gianpiero; Antonio, Ian Dell'

    2001-01-01

    We describe the main features of the BMW survey of serendipitous X-ray clusters, based on the still unexploited ROSAT-HRI archival observations. The sky coverage, surface density and first deep optical CCD images of the candidates indicate that this sample can represent an excellent complement to the existing PSPC deep cluster surveys and will provide us with a fully independent probe of the evolution of the cluster abundance, in addition to significantly increasing the number of clusters known at z>0.6.

  17. The color of X-rays: Spectral X-ray computed tomography using energy sensitive pixel detectors

    NARCIS (Netherlands)

    E.J. Schioppa

    2014-01-01

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray flu

  18. Characterizing X-Ray and Radio Emission in the Black Hole X-Ray Binary V404 Cygni During Quiescence

    DEFF Research Database (Denmark)

    Rana, Vikram; Loh, Alan; Corbel, Stephane;

    2016-01-01

    We present results from multi-wavelength simultaneous X-ray and radio observations of the black hole X-ray binary V404 Cyg in quiescence. Our coverage with NuSTAR provides the very first opportunity to study the X-ray spectrum of V404 Cyg at energies above 10 keV. The unabsorbed broadband (0.3–30...

  19. Low Mass X-ray Binaries As the Source of the Very Soft X-ray Emission in the X-ray Faintest Early-Type Galaxies

    OpenAIRE

    Irwin, Jimmy A.; Sarazin, Craig L.

    1997-01-01

    The X-ray emission from the faintest X-ray elliptical and S0 galaxies is characterized by a hard ~5 keV component, and a very soft ~0.2 keV component. The hard component has generally been regarded as the integrated emission from low mass X-ray binaries (LMXBs), but the origin of the soft component is unknown. We present evidence which suggests that LMXBs also exhibit a soft component, which is responsible for the very soft X-ray emission in the faintest early-type galaxies. This soft compone...

  20. The Correlation between Hard X-Ray Peak Flux and Soft X-Ray Peak Flux in the Outburst Rise of Low-Mass X-Ray Binaries

    OpenAIRE

    Yu, W.; Klis, van der, M.; Fender, R. P.

    2004-01-01

    We have analyzed Rossi X-Ray Timing Explorer pointed observations of the outbursts of black hole and neutron star soft X-ray transients in which an initial low/hard state, or ``island'' state, followed by a transition to a softer state was observed. In three sources-the black hole transient XTE J1550-564, the neutron star transient Aquila X-1, and the quasi-persistent neutron star low-mass X-ray binary 4U 1705-44-two such outbursts were found. We find that the flux of the soft X-ray peak, whi...

  1. X-ray Variability of AGN and the Flare Model

    OpenAIRE

    Goosmann, R. W.; Czerny, B.; Dumont, A. -M.; Mouchet, M.; Rozanska, A.

    2004-01-01

    Short-term variability of X-ray continuum spectra has been reported for several Active Galactic Nuclei. Significant X-ray flux variations are observed within time scales down to 10^3-10^5 seconds. We discuss short variability time scales in the frame of the X-ray flare model, which assumes the release of a large hard X-ray flux above a small portion of the accretion disk. The resulting observed X-ray spectrum is composed of the primary radiation and of a reprocessed Compton reflection compone...

  2. Proceedings of the workshop on X-ray computed microtomography

    International Nuclear Information System (INIS)

    This report consists of vugraphs from the nine presentations at the conference. Titles of the presentations are: CMT: Applications and Techniques; Computer Microtomography Using X-rays from Third Generation Synchrotron X-ray; Approaches to Soft-X-ray Nanotomography; Diffraction Enhanced Tomography; X-ray Computed Microtomography Applications at the NSLS; XCMT Applications in Forestry and Forest Products; 3DMA: Investigating Three Dimensional Pore Geometry from High Resolution Images; X-ray Computed Microtomography Studies of Volcanic Rock; and 3-D Visualization of Tomographic Volumes

  3. Development of coherent x-rays in the APRI

    International Nuclear Information System (INIS)

    The generation of coherent x-ray source using intense laser pulses has attracted much attention due to its broad applications to x-ray spectroscopy, high resolution imaging and holography. There are two different methods to generate coherent x-rays using intense laser pulses: one is the high-order harmonic generation (HHG) and the other is the x-ray lasers (XRL). In this proceeding, we report progress and plan of coherent x-ray generation including HHG and XRL using an 100-TW Ti:Sapphire laser in the APRI. (author)

  4. Observational Aspects of Hard X-ray Polarimetry

    OpenAIRE

    Chattopadhyay, Tanmoy; Vadawale, Santosh

    2016-01-01

    Sensitive polarization measurements in X-ray may address a wealth of astrophysical phenomena, which so far remain beyond our understanding through available X-ray spectroscopic, imaging, and timing studies. Though scientific potential of X-ray polarimetry was realized long ago, there has not been any significant advancement in this field for the last four decades since the birth of X-ray astronomy. The only successful polarization measurement in X-rays dates ...

  5. Prospects for supermirrors in hard x-ray spectroscopy

    DEFF Research Database (Denmark)

    Joensen, Karsten D.; Gorenstein, Paul; Christensen, Finn Erland;

    1994-01-01

    reflectivity for x rays. For hard x rays (≥ 15 keV), the absorption, however, is low enough that it is possible to design supermirrors with 10 - 70% reflectivity in a band ≈ 3 times the width of the total reflection regime. Supermirrors of W/Si and Ni/C have been successfully fabricated and characterized....... The measured x-ray reflectivities are well accounted for by the standard dynamical theories of multilayer reflection. Hard x ray applications that could benefit from x-ray supermirror coatings include focusing and imaging instrumentation for astrophysics, collimating and focusing devices for synchrotron...

  6. X-ray intensity interferometer for synchrotron radiation

    International Nuclear Information System (INIS)

    We propose to measure the transverse coherence of an x-ray beam, for the first time, by Hanbury Brown intensity interferometry. Our approach is to use an intensity interferometer adapted to the soft x-ray region. The X1 or X13 soft x-ray undulator at the National Synchrotron Light Source will supply the partially coherent x-rays. We are developing this technique to characterize the coherence properties of x-ray beams from high brilliance insertion devices at third-generation synchrotron light facilities such as the Advanced Photon Source

  7. Medical x-ray sensitive apparatus based on CCDs

    Science.gov (United States)

    Gnedenko, Valeri G.; Phajnberg, E.; Krasnjuk, Andrew A.; Stenin, Vladimir J.; Larionov, S.; Salnikova, O.; Shilin, Victor A.; Screalev, Alexander S.

    1997-08-01

    Charge-coupled devices have possibility to sense X-rays. The X-ray sensitivity of CCDs is higher than the same for X-ray films. We have designed the experimental miniaturized X-ray CCD camera for dental practice and diagnosis. The CCD analog output signals converse to a digital form, the digital signals are processing by a computer and visible images are forming at the display. The problems of creation and design of X-ray sensitive large format CCD cameras for hard and cancer diagnosis are described.

  8. Dante Soft X-ray Power Diagnostic for NIF

    Energy Technology Data Exchange (ETDEWEB)

    Dewald, E; Campbell, K; Turner, R; Holder, J; Landen, O; Glenzer, S; Kauffman, R; Suter, L; Landon, M; Rhodes, M; Lee, D

    2004-04-15

    Soft x-ray power diagnostics are essential for measuring spectrally resolved the total x-ray flux, radiation temperature, conversion efficiency and albedo that are important quantities for the energetics of indirect drive hohlraums. At the Nova or Omega Laser Facilities, these measurements are performed mainly with Dante, but also with DMX and photo-conductive detectors (PCD's). The Dante broadband spectrometer is a collection of absolute calibrated vacuum x-ray diodes, thin filters and x-ray mirrors used to measure the soft x-ray emission for photon energies above 50 eV.

  9. Proceedings of the workshop on X-ray computed microtomography

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    This report consists of vugraphs from the nine presentations at the conference. Titles of the presentations are: CMT: Applications and Techniques; Computer Microtomography Using X-rays from Third Generation Synchrotron X-ray; Approaches to Soft-X-ray Nanotomography; Diffraction Enhanced Tomography; X-ray Computed Microtomography Applications at the NSLS; XCMT Applications in Forestry and Forest Products; 3DMA: Investigating Three Dimensional Pore Geometry from High Resolution Images; X-ray Computed Microtomography Studies of Volcanic Rock; and 3-D Visualization of Tomographic Volumes.

  10. Soft and Supersoft X-ray Sources in Symbiotic Stars

    OpenAIRE

    Zhu, Chunhua; Lu, Guoliang; Wang, Zhaojun; Jun ZHANG

    2009-01-01

    Assuming that soft X-ray sources in symbiotic stars result from strong thermonuclear runaways, and supersoft X-ray sources from weak thermonuclear runaways or steady hydrogen burning symbiotic stars, we investigate the Galactic soft and supersoft X-ray sources in symbiotic stars by means of population synthesis. The Galactic occurrence rates of soft X-ray sources and supersoft X-ray sources are from $\\sim$ 2 to 20 $\\rm yr^{-1}$, and $\\sim$ 2 to 17 $\\rm yr^{-1}$, respectively. The numbers of X...

  11. HgMn Stars as apparent X-ray emitters

    OpenAIRE

    Hubrig, S.; Berghoefer, W.; Mathys, G.

    1998-01-01

    In the ROSAT all-sky survey 11 HgMn stars were detected as soft X-ray emitters (Berghoefer, Schmitt & Cassinelli 1996). Prior to ROSAT, X-ray observations with the Einstein Observatory had suggested that stars in the spectral range B5-A7 are devoid of X-ray emission. Since there is no X-ray emitting mechanism available for these stars (also not for HgMn stars), the usual argument in the case of an X-ray detected star of this spectral type is the existence of an unseen low-mass companion which...

  12. Soft X-Ray Emissions from Planets and Moons

    Science.gov (United States)

    Bhardwaj, A.; Gladstone, G. R.; Elsner, R. F.; Waite, J. H., Jr.; Grodent, D.; Lewis, W. S.; Crary, F. J.; Weisskopf, M. C.; Howell, R. R.; Johnson, R. E.; Six, N. Frank (Technical Monitor)

    2002-01-01

    The soft x-ray energy band (less than 4 keV) is an important spectral regime for planetary remote sensing, as a wide variety of solar system objects are now known to shine at these wavelengths. These include Earth, Jupiter, comets, moons, Venus, and the Sun. Earth and Jupiter, as magnetic planets, are observed to emanate strong x-ray emissions from their auroral (polar) regions, thus providing vital information on the nature of precipitating particles and their energization processes in planetary magnetospheres. X rays from low latitudes have also been observed on these planets, resulting largely from atmospheric scattering and fluorescence of solar x-rays. Cometary x-rays are now a well established phenomena, more than a dozen comets have been observed at soft x-ray energies, with the accepted production mechanism being charge-exchange between heavy solar wind ions and cometary neutrals. Also, Lunar x-rays have been observed and are thought to be produced by scattering and fluorescence of solar x-rays from the Moon's surface. With the advent of sophisticated x-ray observatories, e.g., Chandra and XMM-Newton, the field of planetary x-ray astronomy is advancing at a much faster pace. The Chandra X-ray Observatory (CXO) has recently captured soft x-rays from Venus. Venusian x-rays are most likely produced through fluorescence of solar x-rays by C and O atoms in the upper atmosphere. Very recently, using CXO we have discovered soft x-rays from the moons of Jupiter-Io, Europa, and probably Ganymede. The plausible source of the x-rays from the Galilean satellites is bombardment of their surfaces by energetic (greater than 10 KeV) ions from the inner magnetosphere of Jupiter. The Io plasma Torus (IPT) is also discovered by CXO to be a source of soft x-rays by CXO have revealed a mysterious pulsating (period approx. 45 minutes) x-ray hot spot is fixed in magnetic latitude and longitude and is magnetically connected to a region in the outer magnetosphere of Jupiter. These

  13. X-ray source populations in the Magellanic Clouds

    OpenAIRE

    Haberl, F.; Pietsch, W.

    2007-01-01

    Early X-ray surveys of the Magellanic Clouds (MCs) were performed with the imaging instruments of the Einstein, ASCA and ROSAT satellites revealing discrete X-ray sources and large-scale diffuse emission. Large samples of supernova remnants, high and low mass X-ray binaries and super-soft X-ray sources could be studied in detail. Today, the major X-ray observatories XMM-Newton and Chandra with their advanced angular and spectral resolution and extended energy coverage are ideally suited for d...

  14. Fundamentals of energy dispersive X-ray analysis

    CERN Document Server

    Russ, John C; Kiessling, R; Charles, J

    1984-01-01

    Fundamentals of Energy Dispersive X-ray Analysis provides an introduction to the fundamental principles of dispersive X-ray analysis. It presents descriptions, equations, and graphs to enable the users of these techniques to develop an intuitive and conceptual image of the physical processes involved in the generation and detection of X-rays. The book begins with a discussion of X-ray detection and measurement, which is accomplished by one of two types of X-ray spectrometer: energy dispersive or wavelength dispersive. The emphasis is on energy dispersive spectrometers, given their rather wid

  15. The Very Local Universe in X-Rays

    Science.gov (United States)

    Ptak, A.

    2011-01-01

    There are many open questions in X-ray observations of the Galactic neighborhood and nearby galaxies, such as the properties of the hot ISM and accreting sources, the X-ray/star-formation rate correlation and how the X-ray luminosity function of starburst galaxies. We discuss how these would be addressed by very wide-area (> 100 sq. deg.) X-ray surveys and upcoming X-ray missions. In particular planned NuStar observations of the Galaxy and nearby galaxies will be highlighted.

  16. A New Method of X-Ray Holographic Tomography

    Institute of Scientific and Technical Information of China (English)

    谢红兰; 陈建文; 高鸿奕; 陆培祥; 徐至展

    2002-01-01

    A new method of x-ray holographic tomography, called pre-amplified x-ray holographic tomography, is proposed to develop an x-ray three-dimensional microscopic imaging technique. In this method, the key component is a micro zone plate taken as an imaging element like an optic lens in x-ray field. Some advantages of the method are shown by a numerical example. The method may make it possible to obtain x-ray microscopic imaging of biological specimens at high resolution in three dimensions.

  17. Simultaneous radio and X-ray observations of Galactic Centre low mass X-ray binaries

    OpenAIRE

    Berendsen, S.G.H.; Fender, R.; Kuulkers, E; Heise, J.; M. van der Klis(Astronomical Institute Anton Pannekoek, University of Amsterdam, The Netherlands)

    2000-01-01

    We have performed simultaneous X-ray and radio observations of thirteen Galactic centre low-mass X-ray binaries in 1998 April using the Wide-Field Cameras onboard BeppoSAX and the Australia Telescope Compact Array, the latter simultaneously at 4.8 and 8.64 GHz. We detect two Z sources, GX 17+2 and GX 5-1, and the unusual `hybrid' source GX 13+1. Upper limits, which are significantly deeper than previous non-detections, are placed on the radio emission from two more Z sources and seven atoll s...

  18. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described:- the Mark I and the Mark II. Both use a bidimensionally sensitive Multiwire proportional counter as the basic X-ray image transducer coupled to a digital microcomputer system. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multi-frame exposures. (author)

  19. Black Holes in Ultra-Luminous X-ray sources: X-ray timing versus spectroscopy

    CERN Document Server

    Caballero-Garcia, M D; Belloni, T M; Wolter, A

    2012-01-01

    Ultra-Luminous X-ray sources are accreting black holes that might represent strong evidence of the Intermediate Mass Black Holes (IMBH), proposed to exist by theoretical studies but with no firm detection (as a class) so far. We analyze the best X-ray timing and spectral data from the ULX in NGC 5408 provided by XMM-Newton. The main goal is to study the broad-band noise variability of the source. We found an anti-correlation of the fractional root-mean square variability versus the intensity of the source, similar to black-hole binaries during hard states.

  20. X-ray emission properties of galaxies in Abell 3128

    CERN Document Server

    Smith, R J

    2003-01-01

    We use archival Chandra X-ray Observatory data to investigate X-ray emission from early-type galaxies in the rich z=0.06 cluster Abell 3128. By combining the X-ray count-rates from an input list of optically-selected galaxies, we obtain a statistical detection of X-ray flux, unbiased by X-ray selection limits. Using 87 galaxies with reliable Chandra data, X-ray emission is detected for galaxies down to M_B ~ -19.0, with only an upper limit determined for galaxies at M_B ~ -18.3. The ratio of X-ray to optical luminosities is consistent with recent determinations of the low-mass X-ray binary content of nearby elliptical galaxies. Taken individually, in contrast, we detect significant (3sigma) flux for only six galaxies. Of these, one is a foreground galaxy, while two are optically-faint galaxies with X-ray hardness ratios characteristic of active galactic nuclei. The remaining three detected galaxies are amongst the optically-brightest cluster members, and have softer X-ray spectra. Their X-ray flux is higher t...

  1. Measurement of specifications of x-ray quality for calibration

    International Nuclear Information System (INIS)

    The filtered continuous X-rays are often used for the calibration and measurement of the energy response of γ-ray dosemeter and dose ratemeter. These X-rays are easily made and sufficiently available for the measurement which does not require the strictly monoenergetic X-ray beam. It is necessary for the employment of continuous X-rays to specify the X-ray qualities such as representative energy and degree of filtration. This report describes a measurement of some specifications of the X-ray quality for a X-ray generator with 50 -- 120 kV of tube potential and a comparison between existing and ISO-4037 proposing expressions on the X-ray quality. According to the resolution of X-ray spectrum, we made four different X-ray quality sets : Wide, Middle, Narrow, and Extra-narrow spectrum series. The information described here about the filtered X-rays will be of use for the calibration and measurement of energy response of the health physics instruments. (J.P.N.)

  2. X-ray microscopy of live biological micro-organisms

    Science.gov (United States)

    Raja Al-Ani, Ma'an Nassar

    Real-time, compact x-ray microscopy has the potential to benefit many scientific fields, including microbiology, pharmacology, organic chemistry, and physics. Single frame x-ray micro-radiography, produced by a compact, solid-state laser plasma source, allows scientists to use x-ray emission for elemental analysis, and to observe biological specimens in their natural state. In this study, x-ray images of mouse kidney tissue, live bacteria, Pseudomonas aeruginosa and Burkholderia cepacia, and the bacteria's interaction with the antibiotic gentamicin, are examined using x-ray microscopy. For the purposes of comparing between confocal microscopy and x-ray microscopy, we introduced to our work the technique of gold labeling. Indirect immunofluorescence staining and immuno-gold labeling were applied on human lymphocytes and human tumor cells. Differential interference contrast microscopy (DIC) showed the lymphocyte body and nucleus, as did x-ray microscopy. However, the high resolution of x-ray microscopy allows us to differentiate between the gold particles bound to the antibodies and the free gold. A compact, tabletop Nd: glass laser is used in this study to produce x-rays from an Yttrium target. An atomic force microscope is used to scan the x-ray images from the developed photo-resist. The use of compact, tabletop laser plasma sources, in conjunction with x-ray microscopy, is a new technique that has great potential as a flexible, user-friendly scientific research tool.

  3. Characterization of a triboelectric x-ray spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Moya-Sanchez, E. Ulises; Romo-Espejel, J. A.; Aceves-Aldrete, F. J. [Departamento de Fisica, CUCEI, Universidad de Guadalajara (Mexico)

    2012-10-23

    Low-energy X-ray imaging system has been useful in medical diagnostic in order to obtain high contrast in soft tissue. Recently, Camara et al. and most recently Hird et al. have produced low-energy X-rays using a triboelectric effect. The main aim of this work is to characterize the penetration (beam quality) of a triboelectric X-ray source in terms of the computed Half Value Layer (HVL). Additionally, the computed HVL of the triboelectric X-ray source has been compared with the HVL of X-ray tube Mo-anode (Apogee 5000). According to our computations the triboelectric X-ray source has a similar penetration such as a X-ray tube source.

  4. Development of scanning electron and x-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Tomokazu, E-mail: tomokzau.matsumura@etd.hpk.co.jp; Hirano, Tomohiko, E-mail: tomohiko.hirano@etd.hpk.co.jp; Suyama, Motohiro, E-mail: suyama@etd.hpk.co.jp [Hamamatsu Photonics K.K., 314-5, Shimokanzo, Iwata City, Shizuoka-Pref. (Japan)

    2016-01-28

    We have developed a new type of microscope possessing a unique feature of observing both scanning electron and X-ray images under one unit. Unlike former X-ray microscopes using SEM [1, 2], this scanning electron and X-ray (SELX) microscope has a sample in vacuum, thus it enables one to observe a surface structure of a sample by SEM mode, to search the region of interest, and to observe an X-ray image which transmits the region. For the X-ray observation, we have been focusing on the soft X-ray region from 280 eV to 3 keV to observe some bio samples and soft materials. The resolutions of SEM and X-ray modes are 50 nm and 100 nm, respectively, at the electron energy of 7 keV.

  5. Backscatter, anisotropy, and polarization of solar hard X-rays

    Science.gov (United States)

    Bai, T.; Ramaty, R.

    1978-01-01

    The problems of anisotropy, polarization, center-to-limb variation of the X-ray spectrum, and Compton backscatter are investigated in a study of solar hard X-rays. Effect of backscatter are found particularly important for anisotropic sources which emit hard X-rays predominantly toward the photosphere; for such anisotropic primary X-ray sources, the observed X-ray flux near 30 keV does not depend significantly on the position of the flare. In addition, the degree of polarization of the sum of the primary and reflected X-rays with energies in the 15 to 30 keV range may be as high as 30%. Determination of the height and anisotropy of the primary X-ray sources from study of the albedo patch is also discussed.

  6. Vanderbilt University free-electron laser x-ray facility

    Science.gov (United States)

    Tompkins, Perry A.; Andrews, Weiwei D.; Brau, Charles A.; Waters, James A.; Carroll, Frank E.; Pickens, David R.; Price, Ronald R.; Roos, Carlton F.

    1993-02-01

    The Vanderbilt University Free-Electron Laser Program is developing the capability to create near-monochromatic x rays for medical imaging and other purposes. For this experiment we feed-back the normal infrared FEL light to collide with the electron beam. This causes Compton backscattering of the incident photons which creates x rays. These x rays cannot feed an x-ray laser, but they have a collimated intensity and tunability which make them highly suitable for medical imaging. This paper is particularly focused on the x-ray beam transport to be used with this experiment. This transport must collimate the x-ray beam and re-direct it to match a beam chase located in the vault ceiling at a 40 degree angle to the electron beam axis. A brief description of the creation mechanism and x-ray beam properties are included.

  7. Test facility for astronomical x-ray optics

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Lewis, Robert A.; Bordas, J.

    1990-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earth's atmosphere. These devices require a large collection aperture and the imaging of an x-ray source that is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions; however, the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area while still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes, is described. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  8. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Haboub, Abdel; MacDowell, Alastair; Marchesini, Stefano; Parkinson, Dilworth

    2013-06-01

    Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

  9. Photoemission measurements for low energy x-ray detector applications

    International Nuclear Information System (INIS)

    Photoemission has been studied for nearly 100 years as both a means of investigating quantum physics, and as a practical technique for transducing optical/x-ray photons into electrical currents. Numerous x-ray detection schemes, such as streak cameras and x-ray sensitive diodes, exploit this process because of its simplicity, adaptability, and speed. Recent emphasis on diagnostics for low temperature, high density, and short-lived, plasmas for inertial confinement fusion has stimulated interest in x-ray photoemission in the sub-kilovolt regime. In this paper, a review of x-ray photoemission measurements in the 50 eV to 10 keV x-ray region is given and the experimental techniques are reviewed. A semiempirical model of x-ray photoemission is discussed and compared to experimental measurements. Finally, examples of absolutely calibrated instruments are shown

  10. A Test Facility For Astronomical X-Ray Optics

    DEFF Research Database (Denmark)

    Lewis, R. A.; Bordas, J.; Christensen, Finn Erland

    1989-01-01

    Grazing incidence x-ray optics for x-ray astronomical applications are used outside the earths atmosphere. These devices require a large collection aperture and the imaging of an x-ray source which is essentially placed at infinity. The ideal testing system for these optical elements has...... to approximate that encountered under working conditions, however the testing of these optical elements is notoriously difficult with conventional x-ray generators. Synchrotron Radiation (SR) sources are sufficiently brilliant to produce a nearly perfect parallel beam over a large area whilst still retaining...... a flux considerably higher than that available from conventional x-ray generators. A facility designed for the testing of x-ray optics, particularly in connection with x-ray telescopes is described below. It is proposed that this facility will be accommodated at the Synchrotron Radiation Source...

  11. Ultra Luminous X-ray Sources

    Science.gov (United States)

    Webb, N. A.; Godet, O.

    2015-12-01

    Ultra Luminous X-ray sources (ULXs) are X-ray bright objects that are not coincident with the central nucleus of the host galaxy and which have luminosities that exceed the Eddington limit for a stellar mass black hole, typically L > 3 × 10^{39} erg s^{-1} for a black hole of 20 M_⊙. The nature of these objects is still unclear. However, it is possible that these sources do not form a single class of objects. Many ULXs may house stellar mass black holes accreting at super-Eddington rates, even if the physical mechanism for such high accretion rates is still not understood. Some ULXs may contain intermediate mass black holes (˜1 × 10^{2} - ˜1 × 10^{5} M_⊙). These elusive black holes are thought to be the building blocks of the more massive supermassive black holes, observed at the centre of many galaxies. Other ULXs may not be accreting black holes at all. Recent evidence for the different types of ULXs is presented in this paper.

  12. Quality assurance in X-ray diagnostics

    International Nuclear Information System (INIS)

    For the purpose of establishing a reference system for quality assessments, the book presents and explains the quality criteria of importance to the X-ray diagnosis of the various body areas, and specifies the particular requirements to be met by the diagnostic technique in order to achieve optimum imaging. As the method of computerized tomography meanwhile is an accepted tool of X-ray diagnostics, the book also refers to this method in particular, stating the quality criteria and the technical requirements. It is dealt with as the tool allowing full utilization of all diagnostic means, with prevention of unnecessary exposure and cost being a high-priority objective. The book also discusses all particulars of the quality control of equipment, explaining various checking systems that in general are in line with the 3-stage concept published by the WHO, covering acceptance tests, in-service inspection, and consistency tests. Practical experience reports by five institutions are put together to present a useful survey of the technical characteristics to be tested, of the tolerance margins, testing methods, and evaluation of results, so that the parameters significance in practice is well explained. With 169 figs., 48 tabs

  13. X-ray spectroscopy of NGC 5548

    CERN Document Server

    Kaastra, J S; Raassen, A J J; Van der Meer, R L J; Brinkman, A C; Liedahl, D A; Behar, E; De Rosa, A

    2002-01-01

    We analyze the high-resolution X-ray spectrum of the Seyfert 1 galaxy NGC 5548, for the full 0.1-10 keV band, using improved calibration results of the Chandra-LETGS instrument. The warm absorber consists of at least three ionization components, namely one with a low, medium and high ionization parameter. The X-ray absorbing material, from an outflowing wind, covers the full range of velocity components found from UV absorption lines. The presence of redshifted emission components for the strongest blue-shifted resonance absorption lines indicate that the absorber is located at a distance larger than the edge of the accretion disk. We derive an upper limit to the edge of the accretion disk of 1 light year. Absorption lines from ions of at least ten chemical elements have been detected, and in general for these elements there are no strong deviations from solar abundances. The narrow emission lines from the O VII and Ne IX forbidden and intercombination lines probably originate from much larger distances to th...

  14. In vivo X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Measurements on five occupationally exposed persons have shown that it is possible to use X-ray fluorescence analysis for in vivo measurements of lead in the skeleton. The technique for calibrating in vivo X-ray fluorescence measurements of lead in bone tissue has been studied in detail and a two-component phantom simulating the bone and the soft tissue parts of the finger constructed. The technique has been used for in vivo measurements on 22 occupationally exposed persons. The minimum detectable concentration of lead in fingerbones was found to be around 20 μg x g-1. The lead concentrations in their skeletons and blood were compared: the correlation was poor. The variations in lead concentrations in the skeleton have been studied in occupationally exposed persons and in samples from archaeological skeletons. The sensitivity and the minimum detectable concentration of cadmium in the kidney cortex in in vivo measurements has been studied by measurements on kidney models. The minimum detectable concentration was 20 μg x g-1 at a skin-kidney distance of 30 mm and 40 μg x g-1 at 40 mm. Five persons occupationally exposed were studied. (Author)

  15. Harmonic lasing in X-ray FELs

    CERN Document Server

    Schneidmiller, E A

    2012-01-01

    Harmonic lasing in a free electron laser with a planar undulator (under the condition that the fundamental frequency is suppressed) might be a cheap and efficient way of extension of wavelength ranges of existing and planned X-ray FEL facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam which is easier to handle due to the suppressed fundamental frequency. In this paper we perform a parametrization of the solution of the eigenvalue equation for lasing at odd harmonics, and present an explicit expression for FEL gain length, taking into account all essential effects. We propose and discuss methods for suppression of the fundamental harmonic. We also suggest a combined use of harmonic lasing and lasing at the retuned fundamental wavelength in order to reduce bandwidth and to increase brilliance of X-ray beam at saturation. Considering 3rd harmonic lasing as a practical example, we come to the conclusion that it is much more robust...

  16. Uranium M x-ray emission spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Keski-Rahkonen, O.; Krause, M.O.

    1977-03-01

    The uranium M x-ray spectrum from a thick metallic target excited by 12-keV electrons was measured by the PAX (photoelectron spectrometry for the analysis of x rays) technique. Energies of the strongest lines were obtained with an accuracy of 0.1 eV using Ag L..beta../sub 1/ and Ag L..cap alpha../sub 1/ as standards. Widths of the uranium lines were obtained by deconvoluting the measured Voigt profiles, and the experimental values were found to agree satisfactorily with McGuire's Hartree-Slater predictions. Natural widths of 4.0(3) and 3.8(3) eV were derived for the M/sub 4/ and M/sub 5/ levels, respectively, and the energies of the M/sub 4/, M/sub 5/, N/sub 2/, and N/sub 3/ levels in uranium metal were determined. Relative intensities of the M lines were measured, and branching ratios were found to be in fair agreement with relativistic Hartree-Slater predictions. The satellite structures of the M..cap alpha../sub 1/ and M..beta.. lines were interpreted in terms of the pertinent multiple-hole configurations. Finally, an approximate analytic expression for the Voigt half-width and its graphical representation are given.

  17. X-ray imaging for security applications

    Science.gov (United States)

    Evans, J. Paul

    2004-01-01

    The X-ray screening of luggage by aviation security personnel may be badly hindered by the lack of visual cues to depth in an image that has been produced by transmitted radiation. Two-dimensional "shadowgraphs" with "organic" and "metallic" objects encoded using two different colors (usually orange and blue) are still in common use. In the context of luggage screening there are no reliable cues to depth present in individual shadowgraph X-ray images. Therefore, the screener is required to convert the 'zero depth resolution' shadowgraph into a three-dimensional mental picture to be able to interpret the relative spatial relationship of the objects under inspection. Consequently, additional cognitive processing is required e.g. integration, inference and memory. However, these processes can lead to serious misinterpretations of the actual physical structure being examined. This paper describes the development of a stereoscopic imaging technique enabling the screener to utilise binocular stereopsis and kinetic depth to enhance their interpretation of the actual nature of the objects under examination. Further work has led to the development of a technique to combine parallax data (to calculate the thickness of a target material) with the results of a basis material subtraction technique to approximate the target's effective atomic number and density. This has been achieved in preliminary experiments with a novel spatially interleaved dual-energy sensor which reduces the number of scintillation elements required by 50% in comparison to conventional sensor configurations.

  18. Building X-ray Diffraction Calibration Software

    Energy Technology Data Exchange (ETDEWEB)

    Lande, Joshua; /Marlboro Coll.

    2007-10-31

    X-ray diffraction is a technique used to analyze the structure of crystals. It records the interference pattern created when x-rays travel through a crystal. Three dimensional structure can be inferred from these two dimensional diffraction patterns. Before the patterns can be analyzed, diffraction data must be precisely calibrated. Calibration is used to determine the experimental parameters of the particular experiment. This is done by fitting the experimental parameters to the diffraction pattern of a well understood crystal. Fit2D is a software package commonly used to do this calibration but it leaves much to be desired. In particular, it does not give very much control over the calibration of the data, requires a significant amount of manual input, does not allow for the calibration of highly tilted geometries, does not properly explain the assumptions that it is making, and cannot be modified. We build code to do this calibration while at the same time overcoming the limitations of Fit2D. This paper describes the development of the calibration software and the assumptions that are made in doing the calibration.

  19. Femtosecond X-ray magnetic circular dichroism absorption spectroscopy at an X-ray free electron laser.

    Science.gov (United States)

    Higley, Daniel J; Hirsch, Konstantin; Dakovski, Georgi L; Jal, Emmanuelle; Yuan, Edwin; Liu, Tianmin; Lutman, Alberto A; MacArthur, James P; Arenholz, Elke; Chen, Zhao; Coslovich, Giacomo; Denes, Peter; Granitzka, Patrick W; Hart, Philip; Hoffmann, Matthias C; Joseph, John; Le Guyader, Loïc; Mitra, Ankush; Moeller, Stefan; Ohldag, Hendrik; Seaberg, Matthew; Shafer, Padraic; Stöhr, Joachim; Tsukamoto, Arata; Nuhn, Heinz-Dieter; Reid, Alex H; Dürr, Hermann A; Schlotter, William F

    2016-03-01

    X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L(3,2)-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature. PMID:27036761

  20. Eta Carinae: X-ray Line Variations during the 2003 X-ray Minimum, and the Orbit Orientation

    Science.gov (United States)

    Corcoran, M. F.; Henley, D.; Hamaguchi, K.; Khibashi, K.; Pittard, J. M.; Stevens, I. R.; Gull, T. R.

    2007-01-01

    The future evolution of Eta Carinae will be as a supernova (or hypernova) and black hole. The evolution is highly contingent on mass and angular momentum changes and instabilities. The presence of a companion can serve to trigger instabilities and provide pathways for mass and angular momentum exchange loss. X-rays can be used a a key diagnostic tool: x-ray temperatures trace pre-shock wind velocities, periodic x-ray variability traces the orbit, and x-ray line variations traces the flow and orientation of shocked gas. This brief presentation highlights x-ray line variations from the HETG and presents a model of the colliding wind flow.