WorldWideScience

Sample records for 3-d reconstruction tomography

  1. Dose fractionation theorem in 3-D reconstruction (tomography)

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, R.M. [Lawrence Berkeley National Lab., CA (United States)

    1997-02-01

    It is commonly assumed that the large number of projections for single-axis tomography precludes its application to most beam-labile specimens. However, Hegerl and Hoppe have pointed out that the total dose required to achieve statistical significance for each voxel of a computed 3-D reconstruction is the same as that required to obtain a single 2-D image of that isolated voxel, at the same level of statistical significance. Thus a statistically significant 3-D image can be computed from statistically insignificant projections, as along as the total dosage that is distributed among these projections is high enough that it would have resulted in a statistically significant projection, if applied to only one image. We have tested this critical theorem by simulating the tomographic reconstruction of a realistic 3-D model created from an electron micrograph. The simulations verify the basic conclusions of high absorption, signal-dependent noise, varying specimen contrast and missing angular range. Furthermore, the simulations demonstrate that individual projections in the series of fractionated-dose images can be aligned by cross-correlation because they contain significant information derived from the summation of features from different depths in the structure. This latter information is generally not useful for structural interpretation prior to 3-D reconstruction, owing to the complexity of most specimens investigated by single-axis tomography. These results, in combination with dose estimates for imaging single voxels and measurements of radiation damage in the electron microscope, demonstrate that it is feasible to use single-axis tomography with soft X-ray microscopy of frozen-hydrated specimens.

  2. In vivo bioluminescence tomography based on multi-view projection and 3D surface reconstruction

    Science.gov (United States)

    Zhang, Shuang; Wang, Kun; Leng, Chengcai; Deng, Kexin; Hu, Yifang; Tian, Jie

    2015-03-01

    Bioluminescence tomography (BLT) is a powerful optical molecular imaging modality, which enables non-invasive realtime in vivo imaging as well as 3D quantitative analysis in preclinical studies. In order to solve the inverse problem and reconstruct inner light sources accurately, the prior structural information is commonly necessary and obtained from computed tomography or magnetic resonance imaging. This strategy requires expensive hybrid imaging system, complicated operation protocol and possible involvement of ionizing radiation. The overall robustness highly depends on the fusion accuracy between the optical and structural information. In this study we present a pure optical bioluminescence tomographic system (POBTS) and a novel BLT method based on multi-view projection acquisition and 3D surface reconstruction. The POBTS acquired a sparse set of white light surface images and bioluminescent images of a mouse. Then the white light images were applied to an approximate surface model to generate a high quality textured 3D surface reconstruction of the mouse. After that we integrated multi-view luminescent images based on the previous reconstruction, and applied an algorithm to calibrate and quantify the surface luminescent flux in 3D.Finally, the internal bioluminescence source reconstruction was achieved with this prior information. A BALB/C mouse with breast tumor of 4T1-fLuc cells mouse model were used to evaluate the performance of the new system and technique. Compared with the conventional hybrid optical-CT approach using the same inverse reconstruction method, the reconstruction accuracy of this technique was improved. The distance error between the actual and reconstructed internal source was decreased by 0.184 mm.

  3. Reconstruction of 3D ion beam micro-tomography data for applications in Cell Biology

    Energy Technology Data Exchange (ETDEWEB)

    Habchi, C. [Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, Gradignan F-33175 (France)], E-mail: habchi@cenbg.in2p3.fr; Nguyen, D.T.; Barberet, Ph. [Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, Gradignan F-33175 (France); Incerti, S. [CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, Gradignan F-33175 (France); Moretto, Ph. [Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, Gradignan F-33175 (France); Sakellariou, A. [Research School of Physical Sciences and Engineering, Australian National University, Canberra ACT 0200 (Australia); Seznec, H. [CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, Gradignan F-33175 (France)

    2009-06-15

    The DISRA (Discrete Image Space Reconstruction Algorithm) reconstruction code, created by A. Sakellariou, was conceived for the ideal case of complete three-dimensional (3D) PIXET (Particle Induced X-ray Emission Tomography) data. This implies two major difficulties for biological samples: first, the long duration of such experiments and second, the subsequent damage that occurs on such fragile specimens. For this reason, the DISRA code was extended at CENBG in order to probe isolated PIXET slices, taking into account the sample structure and mass density provided by 3D STIMT (Scanning Transmission Ion Microscopy Tomography) in the volume of interest. This modified version was tested on a phantom sample and first results on human cancer cells are also presented.

  4. Reconstruction of 3D ion beam micro-tomography data for applications in Cell Biology

    Science.gov (United States)

    Habchi, C.; Nguyen, D. T.; Barberet, Ph.; Incerti, S.; Moretto, Ph.; Sakellariou, A.; Seznec, H.

    2009-06-01

    The DISRA (Discrete Image Space Reconstruction Algorithm) reconstruction code, created by A. Sakellariou, was conceived for the ideal case of complete three-dimensional (3D) PIXET (Particle Induced X-ray Emission Tomography) data. This implies two major difficulties for biological samples: first, the long duration of such experiments and second, the subsequent damage that occurs on such fragile specimens. For this reason, the DISRA code was extended at CENBG in order to probe isolated PIXET slices, taking into account the sample structure and mass density provided by 3D STIMT (Scanning Transmission Ion Microscopy Tomography) in the volume of interest. This modified version was tested on a phantom sample and first results on human cancer cells are also presented.

  5. 2D and 3D reconstructions in acousto-electric tomography

    KAUST Repository

    Kuchment, Peter

    2011-04-18

    We propose and test stable algorithms for the reconstruction of the internal conductivity of a biological object using acousto-electric measurements. Namely, the conventional impedance tomography scheme is supplemented by scanning the object with acoustic waves that slightly perturb the conductivity and cause the change in the electric potential measured on the boundary of the object. These perturbations of the potential are then used as the data for the reconstruction of the conductivity. The present method does not rely on \\'perfectly focused\\' acoustic beams. Instead, more realistic propagating spherical fronts are utilized, and then the measurements that would correspond to perfect focusing are synthesized. In other words, we use synthetic focusing. Numerical experiments with simulated data show that our techniques produce high-quality images, both in 2D and 3D, and that they remain accurate in the presence of high-level noise in the data. Local uniqueness and stability for the problem also hold. © 2011 IOP Publishing Ltd.

  6. GPS tomography: validation of reconstructed 3-D humidity fields with radiosonde profiles

    Directory of Open Access Journals (Sweden)

    M. Shangguan

    2013-09-01

    Full Text Available Water vapor plays an important role in meteorological applications; GeoForschungsZentrum (GFZ therefore developed a tomographic system to derive 3-D distributions of the tropospheric water vapor above Germany using GPS data from about 300 ground stations. Input data for the tomographic reconstructions are generated by the Earth Parameter and Orbit determination System (EPOS software of the GFZ, which provides zenith total delay (ZTD, integrated water vapor (IWV and slant total delay (STD data operationally with a temporal resolution of 2.5 min (STD and 15 min (ZTD, IWV. The water vapor distribution in the atmosphere is derived by tomographic reconstruction techniques. The quality of the solution is dependent on many factors such as the spatial coverage of the atmosphere with slant paths, the spatial distribution of their intersections and the accuracy of the input observations. Independent observations are required to validate the tomographic reconstructions and to get precise information on the accuracy of the derived 3-D water vapor fields. To determine the quality of the GPS tomography, more than 8000 vertical water vapor profiles at 13 German radiosonde stations were used for the comparison. The radiosondes were launched twice a day (at 00:00 UTC and 12:00 UTC in 2007. In this paper, parameters of the entire profiles such as the wet refractivity, and the zenith wet delay have been compared. Before the validation the temporal and spatial distribution of the slant paths, serving as a basis for tomographic reconstruction, as well as their angular distribution were studied. The mean wet refractivity differences between tomography and radiosonde data for all points vary from −1.3 to 0.3, and the root mean square is within the range of 6.5–9. About 32% of 6803 profiles match well, 23% match badly and 45% are difficult to classify as they match only in parts.

  7. GPS tomography. Validation of reconstructed 3-D humidity fields with radiosonde profiles

    Energy Technology Data Exchange (ETDEWEB)

    Shangguan, M.; Bender, M.; Ramatschi, M.; Dick, G.; Wickert, J. [Helmholtz Centre Potsdam, German Research Centre for Geosciences (GFZ), Potsdam (Germany); Raabe, A. [Leipzig Institute for Meteorology (LIM), Leipzig (Germany); Galas, R. [Technische Univ. Berlin (Germany). Dept. for Geodesy and Geoinformation Sciences

    2013-11-01

    Water vapor plays an important role in meteorological applications; GeoForschungsZentrum (GFZ) therefore developed a tomographic system to derive 3-D distributions of the tropospheric water vapor above Germany using GPS data from about 300 ground stations. Input data for the tomographic reconstructions are generated by the Earth Parameter and Orbit determination System (EPOS) software of the GFZ, which provides zenith total delay (ZTD), integrated water vapor (IWV) and slant total delay (STD) data operationally with a temporal resolution of 2.5 min (STD) and 15 min (ZTD, IWV). The water vapor distribution in the atmosphere is derived by tomographic reconstruction techniques. The quality of the solution is dependent on many factors such as the spatial coverage of the atmosphere with slant paths, the spatial distribution of their intersections and the accuracy of the input observations. Independent observations are required to validate the tomographic reconstructions and to get precise information on the accuracy of the derived 3-D water vapor fields. To determine the quality of the GPS tomography, more than 8000 vertical water vapor profiles at 13 German radiosonde stations were used for the comparison. The radiosondes were launched twice a day (at 00:00 UTC and 12:00 UTC) in 2007. In this paper, parameters of the entire profiles such as the wet refractivity, and the zenith wet delay have been compared. Before the validation the temporal and spatial distribution of the slant paths, serving as a basis for tomographic reconstruction, as well as their angular distribution were studied. The mean wet refractivity differences between tomography and radiosonde data for all points vary from -1.3 to 0.3, and the root mean square is within the range of 6.5-9. About 32% of 6803 profiles match well, 23% match badly and 45% are difficult to classify as they match only in parts.

  8. 3-D reconstruction of an ancient Egyptian mummy using X-ray computer tomography.

    Science.gov (United States)

    Baldock, C; Hughes, S W; Whittaker, D K; Taylor, J; Davis, R; Spencer, A J; Tonge, K; Sofat, A

    1994-12-01

    Computer tomography has been used to image and reconstruct in 3-D an Egyptian mummy from the collection of the British Museum. This study of Tjentmutengebtiu, a priestess from the 22nd dynasty (945-715 BC) revealed invaluable information of a scientific, Egyptological and palaeopathological nature without mutilation and destruction of the painted cartonnage case or linen wrappings. Precise details on the removal of the brain through the nasal cavity and the viscera from the abdominal cavity were obtained. The nature and composition of the false eyes were investigated. The detailed analysis of the teeth provided a much closer approximation of age at death. The identification of materials used for the various amulets including that of the figures placed in the viscera was graphically demonstrated using this technique.

  9. Analysis of bite marks in foodstuffs by computer tomography (cone beam CT)--3D reconstruction.

    Science.gov (United States)

    Marques, Jeidson; Musse, Jamilly; Caetano, Catarina; Corte-Real, Francisco; Corte-Real, Ana Teresa

    2013-12-01

    The use of three-dimensional (3D) analysis of forensic evidence is highlighted in comparison with traditional methods. This three-dimensional analysis is based on the registration of the surface from a bitten object. The authors propose to use Cone Beam Computed Tomography (CBCT), which is used in dental practice, in order to study the surface and interior of bitten objects and dental casts of suspects. In this study, CBCT is applied to the analysis of bite marks in foodstuffs, which may be found in a forensic case scenario. 6 different types of foodstuffs were used: chocolate, cheese, apple, chewing gum, pizza and tart (flaky pastry and custard). The food was bitten into and dental casts of the possible suspects were made. The dental casts and bitten objects were registered using an x-ray source and the CBCT equipment iCAT® (Pennsylvania, EUA). The software InVivo5® (Anatomage Inc, EUA) was used to visualize and analyze the tomographic slices and 3D reconstructions of the objects. For each material an estimate of its density was assessed by two methods: HU values and specific gravity. All the used materials were successfully reconstructed as good quality 3D images. The relative densities of the materials in study were compared. Amongst the foodstuffs, the chocolate had the highest density (median value 100.5 HU and 1,36 g/cm(3)), while the pizza showed to have the lowest (median value -775 HU and 0,39 g/cm(3)), on both scales. Through tomographic slices and three-dimensional reconstructions it was possible to perform the metric analysis of the bite marks in all the foodstuffs, except for the pizza. These measurements could also be obtained from the dental casts. The depth of the bite mark was also successfully determined in all the foodstuffs except for the pizza. Cone Beam Computed Tomography has the potential to become an important tool for forensic sciences, namely for the registration and analysis of bite marks in foodstuffs that may be found in a crime

  10. 3D phase micro-object studies by means of digital holographic tomography supported by algebraic reconstruction technique

    Science.gov (United States)

    Bilski, B. J.; Jozwicka, A.; Kujawinska, M.

    2007-09-01

    Constant development of microelements' technology requires a creation of new instruments to determine their basic physical parameters in 3D. The most efficient non-destructive method providing 3D information is tomography. In this paper we present Digital Holographic Tomography (DHT), in which input data is provided by means of Di-git- al Holography (DH). The main advantage of DH is the capability to capture several projections with a single hologram [1]. However, these projections have uneven angular distribution and their number is significantly limited. Therefore - Algebraic Reconstruction Technique (ART), where a few phase projections may be sufficient for proper 3D phase reconstruction, is implemented. The error analysis of the method and its additional limitations due to shape and dimensions of investigated object are presented. Finally, the results of ART application to DHT method are also presented on data reconstructed from numerically generated hologram of a multimode fibre.

  11. A new approach for 3D reconstruction from bright field TEM imaging: Beam precession assisted electron tomography

    International Nuclear Information System (INIS)

    The successful combination of electron beam precession and bright field electron tomography for 3D reconstruction is reported. Beam precession is demonstrated to be a powerful technique to reduce the contrast artifacts due to diffraction and curvature in thin foils. Taking advantage of these benefits, Precession assisted electron tomography has been applied to reconstruct the morphology of Sn precipitates embedded in an Al matrix, from a tilt series acquired in a range from +49o to -61o at intervals of 2o and with a precession angle of 0.6o in bright field mode. The combination of electron tomography and beam precession in conventional TEM mode is proposed as an alternative procedure to obtain 3D reconstructions of nano-objects without a scanning system or a high angle annular dark field detector. -- Highlights: → Electron beam precession reduces spurious diffraction contrast in bright field mode. → Bend contour related contrast depends on precession angle. → Electron beam precession is combined with bright field electron tomography. → Precession assisted BF tomography allowed 3D reconstruction of a Sn precipitate.

  12. Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography

    International Nuclear Information System (INIS)

    We investigate fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography for applications in small animal imaging. Our forward model uses a diffusion approximation for optically inhomogeneous tissue, which we solve using a finite element method (FEM). We examine two approaches to incorporating the forward model into the solution of the inverse problem. In a conventional direct calculation approach one computes the full forward model by repeated solution of the FEM problem, once for each potential source location. We describe an alternative on-the-fly approach where one does not explicitly solve for the full forward model. Instead, the solution to the forward problem is included implicitly in the formulation of the inverse problem, and the FEM problem is solved at each iteration for the current image estimate. We evaluate the convergence speeds of several representative iterative algorithms. We compare the computation cost of those two approaches, concluding that the on-the-fly approach can lead to substantial reductions in total cost when combined with a rapidly converging iterative algorithm

  13. 3D reconstruction for partial data electrical impedance tomography using a sparsity prior

    DEFF Research Database (Denmark)

    Garde, Henrik; Knudsen, Kim

    2015-01-01

    In electrical impedance tomography the electrical conductivity inside a physical body is computed from electro-static boundary measurements. The focus of this paper is to extend recent results for the 2D problem to 3D: prior information about the sparsity and spatial distribution of the conductiv...

  14. 3D Reconstruction of the Glycocalyx Structure in Mammalian Capillaries using Electron Tomography

    DEFF Research Database (Denmark)

    Arkill, Kp; Neal, Cr; Mantell, Jm;

    2012-01-01

    success (e.g. freeze fracture). A new approach is therefore needed. Here we demonstrate the effectiveness of using the relatively novel electron microscopy technique of 3D electron tomography ontwo differently stained preparations to reveal details of the architecture of the glycocalyx just above...

  15. A 3D reconstruction solution to ultrasound Joule heat density tomography based on acousto-electric effect: a simulation study

    Science.gov (United States)

    Yang, R.; Song, A.; Li, X. D.; Lu, Y.; Yan, R.; Xu, B.; Li, X.

    2014-10-01

    A 3D reconstruction solution to ultrasound Joule heat density tomography based on acousto-electric effect by deconvolution is proposed for noninvasive imaging of biological tissue. Compared with ultrasound current source density imaging, ultrasound Joule heat density tomography doesn't require any priori knowledge of conductivity distribution and lead fields, so it can gain better imaging result, more adaptive to environment and with wider application scope. For a general 3D volume conductor with broadly distributed current density field, in the AE equation the ultrasound pressure can't simply be separated from the 3D integration, so it is not a common modulation and basebanding (heterodyning) method is no longer suitable to separate Joule heat density from the AE signals. In the proposed method the measurement signal is viewed as the output of Joule heat density convolving with ultrasound wave. As a result, the internal 3D Joule heat density can be reconstructed by means of Wiener deconvolution. A series of computer simulations set for breast cancer imaging applications, with consideration of ultrasound beam diameter, noise level, conductivity contrast, position dependency and size of simulated tumors, have been conducted to evaluate the feasibility and performance of the proposed reconstruction method. The computer simulation results demonstrate that high spatial resolution 3D ultrasound Joule heat density imaging is feasible using the proposed method, and it has potential applications to breast cancer detection and imaging of other organs.

  16. Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization

    Energy Technology Data Exchange (ETDEWEB)

    Mory, Cyril, E-mail: cyril.mory@philips.com [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Auvray, Vincent; Zhang, Bo [Philips Research Medisys, 33 rue de Verdun, 92156 Suresnes (France); Grass, Michael; Schäfer, Dirk [Philips Research, Röntgenstrasse 24–26, D-22335 Hamburg (Germany); Chen, S. James; Carroll, John D. [Department of Medicine, Division of Cardiology, University of Colorado Denver, 12605 East 16th Avenue, Aurora, Colorado 80045 (United States); Rit, Simon [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Centre Léon Bérard, 28 rue Laënnec, F-69373 Lyon (France); Peyrin, Françoise [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, F-69621 Villeurbanne Cedex (France); X-ray Imaging Group, European Synchrotron, Radiation Facility, BP 220, F-38043 Grenoble Cedex (France); Douek, Philippe; Boussel, Loïc [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1 (France); Hospices Civils de Lyon, 28 Avenue du Doyen Jean Lépine, 69500 Bron (France)

    2014-02-15

    Purpose: Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be recorded during the acquisition and used in the reconstruction. In this paper, the authors present a 4D reconstruction method aiming to reconstruct the heart from a single sweep 10 s acquisition. Methods: The authors introduce the 4D RecOnstructiOn using Spatial and TEmporal Regularization (short 4D ROOSTER) method, which reconstructs all cardiac phases at once, as a 3D + time volume. The algorithm alternates between a reconstruction step based on conjugate gradient and four regularization steps: enforcing positivity, averaging along time outside a motion mask that contains the heart and vessels, 3D spatial total variation minimization, and 1D temporal total variation minimization. Results: 4D ROOSTER recovers the different temporal representations of a moving Shepp and Logan phantom, and outperforms both ECG-gated simultaneous algebraic reconstruction technique and prior image constrained compressed sensing on a clinical case. It generates 3D + time reconstructions with sharp edges which can be used, for example, to estimate the patient's left ventricular ejection fraction. Conclusions: 4D ROOSTER can be applied for human cardiac C-arm CT, and potentially in other dynamic tomography areas. It can easily be adapted to other problems as regularization is decoupled from projection and back projection.

  17. 3D Reconstruction of Intricate Archean Microbial Structures Using Neutron Computed Tomography and Serial Sectioning

    Science.gov (United States)

    Huerta, N. J.; Murphy, M. A.; Natarajan, V.; Weber, G.; Hamann, B.; Sumner, D. Y.

    2005-12-01

    Three-dimensional visualization of intricate microbial structures in rocks is essential to understand the growth of ancient microbial communities. We have imaged and reconstructed the three-dimensional morphology of 2.5-2.6 billion year old intricate microbialites preserved in carbonate using both serial sectioning and neutron computed tomography (NCT). Reconstruction techniques vary with data type and sample preservation. NCT is a non-destructive technique for imaging organic-containing samples with sufficiently high hydrogen concentrations. The resolution of reconstruction is finer than 500 microns. We reconstructed microbialites preserved as organic inclusions in calcite using NCT. Reconstructions are interpreted using volume rendering, segmentation, and an interactive Matlab/visualization environment. Visualizations demonstrate the intricacy of the structures. Noise currently limits automatic growth surface extraction, but growth of structures can be qualitatively evaluated. One of the largest obstacles to date is efficient manipulation of large data sets. Our current visualization approach always renders the supplied data set at full resolution, which requires down-sampling of datasets larger than 256 pixels3 (acquired volume data consists of up to 2048 pixels3) to isolate regions of interest and extract important features. We are exploring the use of multi-resolution techniques that store a dataset at different levels of detail and chose an appropriate resolution during user-interaction. Such an approach will allow us to visualize raw data at full resolution. Serial sectioning and scanning successive horizons provides reconstructions of samples lacking sufficient hydrogen for NCT. This technique destroys the sample and has a lower resolution than NCT. However, intricate networks of microbial laminae surrounded by cement-filled voids can be characterized using this technique. After microbial surfaces are manually interpreted on slices, the images lack noise

  18. Preclinical, fluorescence and diffuse optical tomography: non-contact instrumentation, modeling and time-resolved 3D reconstruction

    International Nuclear Information System (INIS)

    Time-Resolved Diffuse Optical Tomography (TR-DOT) is a new non-invasive imaging technique increasingly used in the clinical and preclinical fields. It yields optical absorption and scattering maps of the explored organs, and related physiological parameters. Time-Resolved Fluorescence Diffuse Optical Tomography (TR-FDOT) is based on the detection of fluorescence photons. It provides spatio-temporal maps of fluorescent probe concentrations and life times, and allows access to metabolic and molecular imaging which is important for diagnosis and therapeutic monitoring, particularly in oncology. The main goal of this thesis was to reconstruct 3D TR-DOT/TR-FDOT images of small animals using time-resolved optical technology. Data were acquired using optical fibers fixed around the animal without contact with its surface. The work was achieved in four steps: 1)- Setting up an imaging device to record the 3D coordinates of an animal's surface; 2)- Modeling the no-contact approach to solve the forward problem; 3)- Processing of the measured signals taking into account the impulse response of the device; 4)- Implementation of a new image reconstruction method based on a selection of carefully chosen points. As a result, good-quality 3D optical images were obtained owing to reduced cross-talk between absorption and scattering. Moreover, the computation time was cut down, compared to full-time methods using whole temporal profiles. (author)

  19. 3D Reconstruction Technique for Tomographic PIV

    Institute of Scientific and Technical Information of China (English)

    姜楠; 包全; 杨绍琼

    2015-01-01

    Tomographic particle image velocimetry(Tomo-PIV) is a state-of-the-art experimental technique based on a method of optical tomography to achieve the three-dimensional(3D) reconstruction for three-dimensional three-component(3D-3C) flow velocity measurements. 3D reconstruction for Tomo-PIV is carried out herein. Meanwhile, a 3D simplified tomographic reconstruction model reduced from a 3D volume light inten-sity field with 2D projection images into a 2D Tomo-slice plane with 1D projecting lines, i.e., simplifying this 3D reconstruction into a problem of 2D Tomo-slice plane reconstruction, is applied thereafter. Two kinds of the most well-known algebraic reconstruction techniques, algebraic reconstruction technique(ART) and multiple algebraic reconstruction technique(MART), are compared as well. The principles of the two reconstruction algorithms are discussed in detail, which has been performed by a series of simulation images, yielding the corresponding recon-struction images that show different features between the ART and MART algorithm, and then their advantages and disadvantages are discussed. Further discussions are made for the standard particle image reconstruction when the background noise of the pre-initial particle image has been removed. Results show that the particle image recon-struction has been greatly improved. The MART algorithm is much better than the ART. Furthermore, the computa-tional analyses of two parameters(the particle density and the number of cameras), are performed to study their effects on the reconstruction. Lastly, the 3D volume particle field is reconstructed by using the improved algorithm based on the simplified 3D tomographic reconstruction model, which proves that the algorithm simplification is feasible and it can be applied to the reconstruction of 3D volume particle field in a Tomo-PIV system.

  20. 3D mouse shape reconstruction based on phase-shifting algorithm for fluorescence molecular tomography imaging system.

    Science.gov (United States)

    Zhao, Yue; Zhu, Dianwen; Baikejiang, Reheman; Li, Changqing

    2015-11-10

    This work introduces a fast, low-cost, robust method based on fringe pattern and phase shifting to obtain three-dimensional (3D) mouse surface geometry for fluorescence molecular tomography (FMT) imaging. We used two pico projector/webcam pairs to project and capture fringe patterns from different views. We first calibrated the pico projectors and the webcams to obtain their system parameters. Each pico projector/webcam pair had its own coordinate system. We used a cylindrical calibration bar to calculate the transformation matrix between these two coordinate systems. After that, the pico projectors projected nine fringe patterns with a phase-shifting step of 2π/9 onto the surface of a mouse-shaped phantom. The deformed fringe patterns were captured by the corresponding webcam respectively, and then were used to construct two phase maps, which were further converted to two 3D surfaces composed of scattered points. The two 3D point clouds were further merged into one with the transformation matrix. The surface extraction process took less than 30 seconds. Finally, we applied the Digiwarp method to warp a standard Digimouse into the measured surface. The proposed method can reconstruct the surface of a mouse-sized object with an accuracy of 0.5 mm, which we believe is sufficient to obtain a finite element mesh for FMT imaging. We performed an FMT experiment using a mouse-shaped phantom with one embedded fluorescence capillary target. With the warped finite element mesh, we successfully reconstructed the target, which validated our surface extraction approach. PMID:26560789

  1. Virtual 3-D Facial Reconstruction

    Directory of Open Access Journals (Sweden)

    Martin Paul Evison

    2000-06-01

    Full Text Available Facial reconstructions in archaeology allow empathy with people who lived in the past and enjoy considerable popularity with the public. It is a common misconception that facial reconstruction will produce an exact likeness; a resemblance is the best that can be hoped for. Research at Sheffield University is aimed at the development of a computer system for facial reconstruction that will be accurate, rapid, repeatable, accessible and flexible. This research is described and prototypical 3-D facial reconstructions are presented. Interpolation models simulating obesity, ageing and ethnic affiliation are also described. Some strengths and weaknesses in the models, and their potential for application in archaeology are discussed.

  2. 3D reconstruction of tensors and vectors

    Energy Technology Data Exchange (ETDEWEB)

    Defrise, Michel; Gullberg, Grant T.

    2005-02-17

    Here we have developed formulations for the reconstruction of 3D tensor fields from planar (Radon) and line-integral (X-ray) projections of 3D vector and tensor fields. Much of the motivation for this work is the potential application of MRI to perform diffusion tensor tomography. The goal is to develop a theory for the reconstruction of both Radon planar and X-ray or line-integral projections because of the flexibility of MRI to obtain both of these type of projections in 3D. The development presented here for the linear tensor tomography problem provides insight into the structure of the nonlinear MRI diffusion tensor inverse problem. A particular application of tensor imaging in MRI is the potential application of cardiac diffusion tensor tomography for determining in vivo cardiac fiber structure. One difficulty in the cardiac application is the motion of the heart. This presents a need for developing future theory for tensor tomography in a motion field. This means developing a better understanding of the MRI signal for diffusion processes in a deforming media. The techniques developed may allow the application of MRI tensor tomography for the study of structure of fiber tracts in the brain, atherosclerotic plaque, and spine in addition to fiber structure in the heart. However, the relations presented are also applicable to other fields in medical imaging such as diffraction tomography using ultrasound. The mathematics presented can also be extended to exponential Radon transform of tensor fields and to other geometric acquisitions such as cone beam tomography of tensor fields.

  3. Three-Phase 3D Reconstruction of a LiCoO2 Cathode via FIB-SEM Tomography.

    Science.gov (United States)

    Liu, Zhao; Chen-Wiegart, Yu-Chen K; Wang, Jun; Barnett, Scott A; Faber, Katherine T

    2016-02-01

    Three-phase three-dimensional (3D) microstructural reconstructions of lithium-ion battery electrodes are critical input for 3D simulations of electrode lithiation/delithiation, which provide a detailed understanding of battery operation. In this report, 3D images of a LiCoO2 electrode are achieved using focused ion beam-scanning electron microscopy (FIB-SEM), with clear contrast among the three phases: LiCoO2 particles, carbonaceous phases (carbon and binder) and the electrolyte space. The good contrast was achieved by utilizing an improved FIB-SEM sample preparation method that combined infiltration of the electrolyte space with a low-viscosity silicone resin and triple ion-beam polishing. Morphological parameters quantified include phase volume fraction, surface area, feature size distribution, connectivity, and tortuosity. Electrolyte tortuosity was determined using two different geometric calculations that were in good agreement. The electrolyte tortuosity distribution versus position within the electrode was found to be highly inhomogeneous; this will lead to inhomogeneous electrode lithiation/delithiation at high C-rates that could potentially cause battery degradation.

  4. The use of 3D computed tomography reconstruction in medico-legal testimony regarding injuries in living victims - Risks and benefits.

    Science.gov (United States)

    Borowska-Solonynko, Aleksandra; Solonynko, Bohdan

    2015-02-01

    Forensic pathologists are often called upon to determine the mechanism and severity of injuries in living individuals. Such expert testimony is often based solely on hand-written clinical notes. The victims' injuries may also be visualized via three-dimensional (3D) reconstruction of computed tomography (CT) images. This method has certain benefits but is not free from limitations. This paper presents two case reports. The first case is that of a female who was brought to the hospital with a knife thrust into her body. The prosecutor's questions focused on the wound channel. The information obtained from the patient's medical records was very general with many contradictory statements. A re-evaluation of the available CT scan data and a subsequent 3D reconstruction helped determine the exact course of the wound channel. The other case was that of a young male, hospitalized based on CT evidence of bilateral rib fractions, who claimed to have been assaulted by police officers. Court expert witnesses were already in possession of a 3D reconstruction showing symmetrical fractures of the patient's lower ribs with bone fragment displacement. An expert witness in radiology definitively excluded the presence of any actual fractures, and explained their apparent visibility in the three-dimensionally reconstructed image as a motion artifact. These two cases suggest that a professionally conducted 3D CT reconstruction is a very useful tool in providing expert testimony on injuries in living victims. However, the deceptive simplicity of conducting such a reconstruction may encourage inexperienced individuals to undertake it, and thus lead to erroneous conclusions. PMID:25623187

  5. 3D reconstruction of VZV infected cell nuclei and PML nuclear cages by serial section array scanning electron microscopy and electron tomography.

    Directory of Open Access Journals (Sweden)

    Mike Reichelt

    Full Text Available Varicella-zoster virus (VZV is a human alphaherpesvirus that causes varicella (chickenpox and herpes zoster (shingles. Like all herpesviruses, the VZV DNA genome is replicated in the nucleus and packaged into nucleocapsids that must egress across the nuclear membrane for incorporation into virus particles in the cytoplasm. Our recent work showed that VZV nucleocapsids are sequestered in nuclear cages formed from promyelocytic leukemia protein (PML in vitro and in human dorsal root ganglia and skin xenografts in vivo. We sought a method to determine the three-dimensional (3D distribution of nucleocapsids in the nuclei of herpesvirus-infected cells as well as the 3D shape, volume and ultrastructure of these unique PML subnuclear domains. Here we report the development of a novel 3D imaging and reconstruction strategy that we term Serial Section Array-Scanning Electron Microscopy (SSA-SEM and its application to the analysis of VZV-infected cells and these nuclear PML cages. We show that SSA-SEM permits large volume imaging and 3D reconstruction at a resolution sufficient to localize, count and distinguish different types of VZV nucleocapsids and to visualize complete PML cages. This method allowed a quantitative determination of how many nucleocapsids can be sequestered within individual PML cages (sequestration capacity, what proportion of nucleocapsids are entrapped in single nuclei (sequestration efficiency and revealed the ultrastructural detail of the PML cages. More than 98% of all nucleocapsids in reconstructed nuclear volumes were contained in PML cages and single PML cages sequestered up to 2,780 nucleocapsids, which were shown by electron tomography to be embedded and cross-linked by an filamentous electron-dense meshwork within these unique subnuclear domains. This SSA-SEM analysis extends our recent characterization of PML cages and provides a proof of concept for this new strategy to investigate events during virion assembly at the

  6. Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

    Science.gov (United States)

    Landis, W. J.; Hodgens, K. J.; McKee, M. D.; Nanci, A.; Song, M. J.; Kiyonaga, S.; Arena, J.; McEwen, B.

    1992-01-01

    To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

  7. Forensic 3D Scene Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    LITTLE,CHARLES Q.; PETERS,RALPH R.; RIGDON,J. BRIAN; SMALL,DANIEL E.

    1999-10-12

    Traditionally law enforcement agencies have relied on basic measurement and imaging tools, such as tape measures and cameras, in recording a crime scene. A disadvantage of these methods is that they are slow and cumbersome. The development of a portable system that can rapidly record a crime scene with current camera imaging, 3D geometric surface maps, and contribute quantitative measurements such as accurate relative positioning of crime scene objects, would be an asset to law enforcement agents in collecting and recording significant forensic data. The purpose of this project is to develop a feasible prototype of a fast, accurate, 3D measurement and imaging system that would support law enforcement agents to quickly document and accurately record a crime scene.

  8. 3D particle tracking velocimetry using dynamic discrete tomography

    NARCIS (Netherlands)

    Alpers, A.; Gritzmann, P.; Moseev, D.; Salewski, M.

    2015-01-01

    Particle tracking velocimetry in 3D is becoming an increasingly important imaging tool in the study of fluid dynamics and combustion as well as plasmas. We introduce a dynamic discrete tomography algorithm for reconstructing particle trajectories from projections. The algorithm is efficient for data

  9. 3D particle tracking velocimetry using dynamic discrete tomography

    DEFF Research Database (Denmark)

    Alpers, Andreas; Gritzmann, Peter; Moseev, Dmitry;

    2015-01-01

    Particle tracking velocimetry in 3D is becoming an increasingly important imaging tool in the study of fluid dynamics and combustion as well as plasmas. We introduce a dynamic discrete tomography algorithm for reconstructing particle trajectories from projections. The algorithm is efficient...

  10. Ordered subsets convex algorithm for 3D terahertz transmission tomography

    OpenAIRE

    Recur, Benoît; Balacey, Hugo; Bou Sleiman, Joyce; Perraud, Jean-Baptiste; Guillet, Jean-Paul; Kingston, Andrew; Mounaix, Patrick

    2014-01-01

    International audience We investigate in this paper a new reconstruction method in order to perform 3D Terahertz (THz) tomography using a continuous wave acquisition setup in transmission mode. This method is based on the Maximum Likelihood for TRansmission tomography (ML-TR) first developed for X-ray imaging. We optimize the Ordered Subsets Convex (OSC) implementation of the ML-TR by including the Gaussian propagation model of THz waves and take into account the intensity distributions of...

  11. Thin slice three dimentional (3D reconstruction versus CT 3D reconstruction of human breast cancer

    Directory of Open Access Journals (Sweden)

    Yi Zhang

    2013-01-01

    Full Text Available Background & objectives: With improvement in the early diagnosis of breast cancer, breast conserving therapy (BCT is being increasingly used. Precise preoperative evaluation of the incision margin is, therefore, very important. Utilizing three dimentional (3D images in a preoperative evaluation for breast conserving surgery has considerable significance, but the currently 3D CT scan reconstruction commonly used has problems in accurately displaying breast cancer. Thin slice 3D reconstruction is also widely used now to delineate organs and tissues of breast cancers. This study was aimed to compare 3D CT with thin slice 3D reconstruction in breast cancer patients to find a better technique for accurate evaluation of breast cancer. Methods: A total of 16-slice spiral CT scans and 3D reconstructions were performed on 15 breast cancer patients. All patients had been treated with modified radical mastectomy; 2D and 3D images of breast and tumours were obtained. The specimens were fixed and sliced at 2 mm thickness to obtain serial thin slice images, and reconstructed using 3D DOCTOR software to gain 3D images. Results: Compared with 2D CT images, thin slice images showed more clearly the morphological characteristics of tumour, breast tissues and the margins of different tissues in each slice. After 3D reconstruction, the tumour shapes obtained by the two reconstruction methods were basically the same, but the thin slice 3D reconstruction showed the tumour margins more clearly. Interpretation & conclusions: Compared with 3D CT reconstruction, thin slice 3D reconstruction of breast tumour gave clearer images, which could provide guidance for the observation and application of CT 3D reconstructed images and contribute to the accurate evaluation of tumours using CT imaging technology.

  12. 3-D Reconstruction From Satellite Images

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    of planetary surfaces, but other purposes is considered as well. The system performance is measured with respect to the precision and the time consumption.The reconstruction process is divided into four major areas: Acquisition, calibration, matching/reconstruction and presentation. Each of these areas......, where various methods have been tested in order to optimize the performance. The match results are used in the reconstruction part to establish a 3-D digital representation and finally, different presentation forms are discussed....

  13. Neural Network Based 3D Surface Reconstruction

    Directory of Open Access Journals (Sweden)

    Vincy Joseph

    2009-11-01

    Full Text Available This paper proposes a novel neural-network-based adaptive hybrid-reflectance three-dimensional (3-D surface reconstruction model. The neural network combines the diffuse and specular components into a hybrid model. The proposed model considers the characteristics of each point and the variant albedo to prevent the reconstructed surface from being distorted. The neural network inputs are the pixel values of the two-dimensional images to be reconstructed. The normal vectors of the surface can then be obtained from the output of the neural network after supervised learning, where the illuminant direction does not have to be known in advance. Finally, the obtained normal vectors can be applied to integration method when reconstructing 3-D objects. Facial images were used for training in the proposed approach

  14. APPLICATION OF 3D MODELING IN 3D PRINTING FOR THE LOWER JAW RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Yu. Yu. Dikov

    2015-01-01

    Full Text Available Aim of study: improvement of functional and aesthetic results of microsurgery reconstructions of the lower jaw due to the use of the methodology of 3D modeling and 3D printing. Application of this methodology has been demonstrated on the example of treatment of 4 patients with locally distributed tumors of the mouth cavity, who underwent excision of the tumor with simultaneous reconstruction of the lower jaw with revascularized fibular graft.Before, one patient has already undergo segmental resection of the lower jaw with the defect replacement with the avascular ileac graft and a reconstruction plate. Then, a relapse of the disease and lysis of the graft has developed with him. Modeling of the graft according to the shape of the lower jaw was performed by making osteotomies of the bone part of the graft using three-dimensional virtual models created by computed tomography data. Then these 3D models were printed with a 3D printer of plastic with the scale of 1:1 with the fused deposition modeling (FDM technology and were used during the surgery in the course of modeling of the graft. Sterilizing of the plastic model was performed in the formalin chamber.This methodology allowed more specific reconstruction of the resected fragment of the lower jaw and get better functional and aesthetic results and prepare patients to further dental rehabilitation. Advantages of this methodology are the possibility of simultaneous performance of stages of reconstruction and resection and shortening of the time of surgery.

  15. 3-D flame temperature field reconstruction with multiobjective neural network

    Institute of Scientific and Technical Information of China (English)

    Xiong Wan(万雄); Yiqing Gao(高益庆); Yuanmei Wang(汪元美)

    2003-01-01

    A novel 3-D temperature field reconstruction method is proposed in this paper, which is based on multi-wavelength thermometry and Hopfield neural network computed tomography. A mathematical modelof multi-wavelength thermometry is founded, and a neural network algorithm based on multiobjectiveoptimization is developed. Through computer simulation and comparison with the algebraic reconstructiontechnique (ART) and the filter back-projection algorithm (FBP), the reconstruction result of the newmethod is discussed in detail. The study shows that the new method always gives the best reconstructionresults. At last, temperature distribution of a section of four peaks candle flame is reconstructed with thisnovel method.

  16. 3D particle tracking velocimetry using dynamic discrete tomography

    CERN Document Server

    Alpers, Andreas; Moseev, Dmitry; Salewski, Mirko

    2013-01-01

    Particle tracking velocimetry in 3D is becoming an increasingly important imaging tool in the study of fluid dynamics, combustion as well as plasmas. We introduce a dynamic discrete tomography algorithm for reconstructing particle trajectories from projections. The algorithm is efficient for data from two projection directions and exact in the sense that it finds a solution consistent with the experimental data. Non-uniqueness of solutions can be detected and solutions can be tracked individually.

  17. Fully 3D GPU PET reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J.L., E-mail: joaquin@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cal-Gonzalez, J. [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Vaquero, J.J. [Departmento de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Desco, M. [Departmento de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Departmento Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Fully 3D iterative tomographic image reconstruction is computationally very demanding. Graphics Processing Unit (GPU) has been proposed for many years as potential accelerators in complex scientific problems, but it has not been used until the recent advances in the programmability of GPUs that the best available reconstruction codes have started to be implemented to be run on GPUs. This work presents a GPU-based fully 3D PET iterative reconstruction software. This new code may reconstruct sinogram data from several commercially available PET scanners. The most important and time-consuming parts of the code, the forward and backward projection operations, are based on an accurate model of the scanner obtained with the Monte Carlo code PeneloPET and they have been massively parallelized on the GPU. For the PET scanners considered, the GPU-based code is more than 70 times faster than a similar code running on a single core of a fast CPU, obtaining in both cases the same images. The code has been designed to be easily adapted to reconstruct sinograms from any other PET scanner, including scanner prototypes.

  18. Fully 3D GPU PET reconstruction

    International Nuclear Information System (INIS)

    Fully 3D iterative tomographic image reconstruction is computationally very demanding. Graphics Processing Unit (GPU) has been proposed for many years as potential accelerators in complex scientific problems, but it has not been used until the recent advances in the programmability of GPUs that the best available reconstruction codes have started to be implemented to be run on GPUs. This work presents a GPU-based fully 3D PET iterative reconstruction software. This new code may reconstruct sinogram data from several commercially available PET scanners. The most important and time-consuming parts of the code, the forward and backward projection operations, are based on an accurate model of the scanner obtained with the Monte Carlo code PeneloPET and they have been massively parallelized on the GPU. For the PET scanners considered, the GPU-based code is more than 70 times faster than a similar code running on a single core of a fast CPU, obtaining in both cases the same images. The code has been designed to be easily adapted to reconstruct sinograms from any other PET scanner, including scanner prototypes.

  19. 3D reconstruction methods of coronal structures by radio observations

    Science.gov (United States)

    Aschwanden, Markus J.; Bastian, T. S.; White, Stephen M.

    1992-11-01

    The ability to carry out the three dimensional (3D) reconstruction of structures in the solar corona would represent a major advance in the study of the physical properties in active regions and in flares. Methods which allow a geometric reconstruction of quasistationary coronal structures (for example active region loops) or dynamic structures (for example flaring loops) are described: stereoscopy of multi-day imaging observations by the VLA (Very Large Array); tomography of optically thin emission (in radio or soft x-rays); multifrequency band imaging by the VLA; and tracing of magnetic field lines by propagating electron beams.

  20. 3D SPIRAL COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF AN ABDOMINAL TUMOUR

    OpenAIRE

    R.C. Tiutiuca; Iuliana Eva

    2006-01-01

    Patients with digestive illnesses requires a full exploration, cases where imagistic assets support (echographic examination, radiological data, computed tomography, magnetic resonance) are very usefully. Computed tomography, in this process, has a special value. The results from axial images are sustained by the informations supplied from three-dimensional reconstruction processes (3D reconstruction) with relevant importance in establishment of diagnosis and therapeutic plan.

  1. A dynamic 3D foot reconstruction system.

    Science.gov (United States)

    Thabet, Ali K; Trucco, Emanuele; Salvi, Joaquim; Wang, Weijie; Abboud, Rami J

    2011-01-01

    Foot problems are varied and range from simple disorders through to complex diseases and joint deformities. Wherever possible, the use of insoles, or orthoses, is preferred over surgery. Current insole design techniques are based on static measurements of the foot, despite the fact that orthoses are prevalently used in dynamic conditions while walking or running. This paper presents the design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion, and its use to show that foot measurements in dynamic conditions differ significantly from their static counterparts. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Engineering and clinical tests were carried out for the validation of the system. The accuracy of the system was found to be 0.34 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.44 mm (static case) and 2.81 mm (dynamic case). Furthermore, a study was performed to compare the effective length of the foot between static and dynamic reconstructions using the 4D system. Results showed an average increase of 9 mm for the dynamic case. This increase is substantial for orthotics design, cannot be captured by a static system, and its subject-specific measurement is crucial for the design of effective foot orthoses.

  2. Optimisation and validation of a 3D reconstruction algorithm for single photon emission computed tomography by means of GATE simulation platform

    International Nuclear Information System (INIS)

    Although time consuming, Monte-Carlo simulations remain an efficient tool enabling to assess correction methods for degrading physical effects in medical imaging. We have optimized and validated a reconstruction method baptized F3DMC (Fully 3D Monte Carlo) in which the physical effects degrading the image formation process were modelled using Monte-Carlo methods and integrated within the system matrix. We used the Monte-Carlo simulation toolbox GATE. We validated GATE in SPECT by modelling the gamma-camera (Philips AXIS) used in clinical routine. Techniques of threshold, filtering by a principal component analysis and targeted reconstruction (functional regions, hybrid regions) were used in order to improve the precision of the system matrix and to reduce the number of simulated photons as well as the time consumption required. The EGEE Grid infrastructures were used to deploy the GATE simulations in order to reduce their computation time. Results obtained with F3DMC were compared with the reconstruction methods (FBP, ML-EM, MLEMC) for a simulated phantom and with the OSEM-C method for the real phantom. Results have shown that the F3DMC method and its variants improve the restoration of activity ratios and the signal to noise ratio. By the use of the grid EGEE, a significant speed-up factor of about 300 was obtained. These results should be confirmed by performing studies on complex phantoms and patients and open the door to a unified reconstruction method, which could be used in SPECT and also in PET. (author)

  3. 3D visualization using pulsed and CW digital holographic tomography techniques (Invited Paper)

    Institute of Scientific and Technical Information of China (English)

    G. Nehmetallah; P. P. Banerjee; D. Ferree; R. Kephart; S. Praharaj

    2011-01-01

    We outline the use of digital holographic tomography to determine the three-dimensional (3D) shapes of falling and static objects, such as lenslets and water droplets. Reconstruction of digitally recorded inline holograms is performed using multiplicative and Radon transform techniques to reveal the exact 3D shapes of the objects.%We outline the use of digital holographic tomography to determine the three-dimensional (3D) shapes of falling and static objects,such as lenslets and water droplets.Reconstruction of digitally recorded inline holograms is performed using multiplicative and Radon transform techniques to reveal the exact 3D shapes of the objects.

  4. 3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

    Energy Technology Data Exchange (ETDEWEB)

    Dibildox, Gerardo, E-mail: g.dibildox@erasmusmc.nl; Baka, Nora; Walsum, Theo van [Biomedical Imaging Group Rotterdam, Departments of Radiology and Medical Informatics, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands); Punt, Mark; Aben, Jean-Paul [Pie Medical Imaging, 6227 AJ Maastricht (Netherlands); Schultz, Carl [Department of Cardiology, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands); Niessen, Wiro [Quantitative Imaging Group, Faculty of Applied Sciences, Delft University of Technology, 2628 CJ Delft, The Netherlands and Biomedical Imaging Group Rotterdam, Departments of Radiology and Medical Informatics, Erasmus Medical Center, 3015 GE Rotterdam (Netherlands)

    2014-09-15

    Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment is achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.

  5. Volumetric (3D) compressive sensing spectral domain optical coherence tomography.

    Science.gov (United States)

    Xu, Daguang; Huang, Yong; Kang, Jin U

    2014-11-01

    In this work, we proposed a novel three-dimensional compressive sensing (CS) approach for spectral domain optical coherence tomography (SD OCT) volumetric image acquisition and reconstruction. Instead of taking a spectral volume whose size is the same as that of the volumetric image, our method uses a sub set of the original spectral volume that is under-sampled in all three dimensions, which reduces the amount of spectral measurements to less than 20% of that required by the Shan-non/Nyquist theory. The 3D image is recovered from the under-sampled spectral data dimension-by-dimension using the proposed three-step CS reconstruction strategy. Experimental results show that our method can significantly reduce the sampling rate required for a volumetric SD OCT image while preserving the image quality.

  6. Animal testing using 3D microwave tomography system for breast cancer detection.

    Science.gov (United States)

    Lee, Jong Moon; Son, Sung Ho; Kim, Hyuk Je; Kim, Bo Ra; Choi, Heyng Do; Jeon, Soon Ik

    2014-01-01

    The three dimensional microwave tomography (3D MT) system of the Electronics and Telecommunications Research Institute (ETRI) comprises an antenna array, transmitting receiving module, switch matrix module and a signal processing component. This system also includes a patient interface bed as well as a 3D reconstruction algorithm. Here, we perform a comparative analysis of image reconstruction results using the assembled system and MRI results, which is used to image the breasts of dogs. Microwave imaging reconstruction results (at 1,500 MHz) obtained using the ETRI 3D MT system are presented. The system provides computationally reliable diagnosis results from the reconstructed MT Image. PMID:25160233

  7. 3D ultrasound computer tomography: update from a clinical study

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Kretzek, E.; Henrich, J.; Tukalo, A.; Gemmeke, H.; Kaiser, C.; Knaudt, J.; Ruiter, N. V.

    2016-04-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging method for breast cancer diagnosis. We developed a 3D USCT system and tested it in a pilot study with encouraging results: 3D USCT was able to depict two carcinomas, which were present in contrast enhanced MRI volumes serving as ground truth. To overcome severe differences in the breast shape, an image registration was applied. We analyzed the correlation between average sound speed in the breast and the breast density estimated from segmented MRIs and found a positive correlation with R=0.70. Based on the results of the pilot study we now carry out a successive clinical study with 200 patients. For this we integrated our reconstruction methods and image post-processing into a comprehensive workflow. It includes a dedicated DICOM viewer for interactive assessment of fused USCT images. A new preview mode now allows intuitive and faster patient positioning. We updated the USCT system to decrease the data acquisition time by approximately factor two and to increase the penetration depth of the breast into the USCT aperture by 1 cm. Furthermore the compute-intensive reflectivity reconstruction was considerably accelerated, now allowing a sub-millimeter volume reconstruction in approximately 16 minutes. The updates made it possible to successfully image first patients in our ongoing clinical study.

  8. Applicability of 3D-CT facial reconstruction for forensic individual identification

    OpenAIRE

    Rocha Sara dos Santos; Ramos Dalton Luiz de Paula; Cavalcanti Marcelo de Gusmão Paraíso

    2003-01-01

    Computed tomography (CT) is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT). The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using craniometric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering techni...

  9. 3D Surface Reconstruction and Automatic Camera Calibration

    Science.gov (United States)

    Jalobeanu, Andre

    2004-01-01

    Illustrations in this view-graph presentation are presented on a Bayesian approach to 3D surface reconstruction and camera calibration.Existing methods, surface analysis and modeling,preliminary surface reconstruction results, and potential applications are addressed.

  10. Glasses for 3D ultrasound computer tomography: phase compensation

    Science.gov (United States)

    Zapf, M.; Hopp, T.; Ruiter, N. V.

    2016-03-01

    Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.

  11. Analysis of the of bones through 3D computerized tomography; Analise de estrutura ossea atraves de microtomografia computadorizada 3D

    Energy Technology Data Exchange (ETDEWEB)

    Lima, I.; Lopes, R.T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear; Oliveira, L.F. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada e Termodinamica; Alves, J.M. [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia

    2009-03-15

    This work shows the analysis of the internal structure of the bones samples through 3D micro tomography technique (3D-{mu}TC). The comprehension of the bone structure is particularly important when related to osteoporosis diagnosis because this implies in a deterioration of the trabecular bone architecture, which increases the fragility and the possibility to have bone fractures. Two bone samples (human calcaneous and Wistar rat femur) were used, and the method was a radiographic system in real time with an X Ray microfocus tube. The quantifications parameters are based on stereological principles and they are five: a bone volume fraction, trabecular number, the ratio between surface and bone volume, the trabecular thickness and the trabecular separation. The quantifications were done with a program developed especially for this purpose in Nuclear Instrumentation Laboratory - COPPE/UFRJ. This program uses as input the 3D reconstructions images and generates a table with the quantifications. The results of the human calcaneous quantifications are presented in tables 1 and 2, and the 3D reconstructions are illustrated in Figure 5. The Figure 6 illustrate the 2D reconstructed image and the Figure 7 the 3D visualization respectively of the Wistar femur sample. The obtained results show that the 3D-{mu}TC is a powerful technique that can be used to analyze bone microstructures. (author)

  12. 3D Reconstruction in Spiral Multislice CT Scans

    Directory of Open Access Journals (Sweden)

    M. Ghafouri

    2005-08-01

    Full Text Available Introduction & Background: The rapid development of spiral (helical computed tomography (CT has resulted in exciting new applications for CT. One of these applications, three-dimensional (3D CT with volume ren-dering, is now a major area of clinical and academic interest. One of the greatest advantages of spiral CT with 3D volume rendering is that it provides all the necessary information in a single radiologic study (and there-fore at the lowest possible price in cases that previously required two or more studies. Three-dimensional vol-ume rendering generates clinically accurate and immediately available images from the full CT data set with-out extensive editing. It allows the radiologist and clinician to address specific questions concerning patient care by interactively exploring different aspects of the data set. Three-dimensional images integrate a series of axial CT sections into a form that is often easier to interpret than the sections themselves and can be made to appear similar to other more familiar images such as catheter angiograms. The data are organized into a 3D matrix of volume elements (voxels. The screen of the computer monitor is a 2D-surface composed of discrete picture elements (pixels. Presenting what is stored in memory (ie, floating within the monitor on a 2D-screen is a challenge, but it is the very problem that 3D reconstruc-tion software has creatively solved. Voxel selection is usually accomplished by projecting lines (rays through the data set that correspond to the pixel matrix of the desired 2D image. Differences in the images produced with various 3D rendering techniques are the result of variations in how voxels are selected and weighted. In this article, I compare 3D volume rendering of spiral CT data with other rendering techniques (shaded surface display, maximum intensity projection and present a brief history of 3D volume rendering and discuss the im-plementation of this promising technology in terms of

  13. Tomographie optique diffuse et de fluorescence préclinique : instrumentation sans contact, modélisation et reconstruction 3D résolue en temps.

    OpenAIRE

    Nouizi, Farouk

    2011-01-01

    Time-Resolved Diffuse Optical Tomography (TR-DOT) is a new non-invasive imaging technique increasingly used in the clinical and preclinical fields. It yields optical absorption and scattering maps of the explored organs, and related physiological parameters. Time-Resolved Fluorescence Diffuse Optical Tomography (TR-FDOT) is based on the detection of fluorescence photons. It provides spatio-temporal maps of fluorescent probe concentrations and life times, and allows access to metabolic and mol...

  14. 3D Reconstruction by Kinect Sensor:A Brief Review

    Institute of Scientific and Technical Information of China (English)

    LI Shi-rui; TAO Ke-lu; WANG Si-yuan; LI Hai-yang; CAO Wei-guo; LI Hua

    2014-01-01

    While Kinect was originally designed as a motion sensing input device of the gaming console Microsoft Xbox 360 for gaming purposes, it’s easy-to-use, low-cost, reliability, speed of the depth measurement and relatively high quality of depth measurement make it can be used for 3D reconstruction. It could make 3D scanning technology more accessible to everyday users and turn 3D reconstruction models into much widely used asset for many applications. In this paper, we focus on Kinect 3D reconstruction.

  15. Reconstruction and analysis of shapes from 3D scans

    NARCIS (Netherlands)

    ter Haar, F.B.

    2009-01-01

    In this thesis we use 3D laser range scans for the acquisition, reconstruction, and analysis of 3D shapes. 3D laser range scanning has proven to be a fast and effective way to capture the surface of an object in a computer. Thousands of depth measurements represent a part of the surface geometry as

  16. Three-Dimensional Optical Coherence Tomography (3D OCT) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Applied Science Innovations, Inc. proposes to develop a new tool of 3D optical coherence tomography (OCT) for cellular level imaging at video frame rates and...

  17. Three-Dimensional Optical Coherence Tomography (3D OCT) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Applied Science Innovations, Inc. proposes a new tool of 3D optical coherence tomography (OCT) for cellular level imaging at video frame rates and dramatically...

  18. Reconstruction of 3-D Temperature Field in Holographic Interferometry

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The tomography technique is commonly used for the reconstruction of holographic interferometry. However, the current reconstruction method doesn't consider the measurement errors which are non-avoidable in the measurement and will degrade the reconstruction quality. The factors affecting the reconstruction quality are analyzed and the distribution law of the reconstruction error with experimental errors is discussed. Finally, a method to improve the reconstruction quality—the Kalman filter method is presented.

  19. 3D scene reconstruction based on 3D laser point cloud combining UAV images

    Science.gov (United States)

    Liu, Huiyun; Yan, Yangyang; Zhang, Xitong; Wu, Zhenzhen

    2016-03-01

    It is a big challenge capturing and modeling 3D information of the built environment. A number of techniques and technologies are now in use. These include GPS, and photogrammetric application and also remote sensing applications. The experiment uses multi-source data fusion technology for 3D scene reconstruction based on the principle of 3D laser scanning technology, which uses the laser point cloud data as the basis and Digital Ortho-photo Map as an auxiliary, uses 3DsMAX software as a basic tool for building three-dimensional scene reconstruction. The article includes data acquisition, data preprocessing, 3D scene construction. The results show that the 3D scene has better truthfulness, and the accuracy of the scene meet the need of 3D scene construction.

  20. 3D Equilibrium Reconstructions in DIII-D

    Science.gov (United States)

    Lao, L. L.; Ferraro, N. W.; Strait, E. J.; Turnbull, A. D.; King, J. D.; Hirshman, H. P.; Lazarus, E. A.; Sontag, A. C.; Hanson, J.; Trevisan, G.

    2013-10-01

    Accurate and efficient 3D equilibrium reconstruction is needed in tokamaks for study of 3D magnetic field effects on experimentally reconstructed equilibrium and for analysis of MHD stability experiments with externally imposed magnetic perturbations. A large number of new magnetic probes have been recently installed in DIII-D to improve 3D equilibrium measurements and to facilitate 3D reconstructions. The V3FIT code has been in use in DIII-D to support 3D reconstruction and the new magnetic diagnostic design. V3FIT is based on the 3D equilibrium code VMEC that assumes nested magnetic surfaces. V3FIT uses a pseudo-Newton least-square algorithm to search for the solution vector. In parallel, the EFIT equilibrium reconstruction code is being extended to allow for 3D effects using a perturbation approach based on an expansion of the MHD equations. EFIT uses the cylindrical coordinate system and can include the magnetic island and stochastic effects. Algorithms are being developed to allow EFIT to reconstruct 3D perturbed equilibria directly making use of plasma response to 3D perturbations from the GATO, MARS-F, or M3D-C1 MHD codes. DIII-D 3D reconstruction examples using EFIT and V3FIT and the new 3D magnetic data will be presented. Work supported in part by US DOE under DE-FC02-04ER54698, DE-FG02-95ER54309 and DE-AC05-06OR23100.

  1. Optimisation and validation of a 3D reconstruction algorithm for single photon emission computed tomography by means of GATE simulation platform; Optimisation et validation d'un algorithme de reconstruction 3D en Tomographie d'Emission Monophotonique a l'aide de la plate forme de simulation GATE

    Energy Technology Data Exchange (ETDEWEB)

    El Bitar, Ziad [Ecole Doctorale des Sciences Fondamentales, Universite Blaise Pascal, U.F.R de Recherches Scientifiques et Techniques, 34, avenue Carnot - BP 185, 63006 Clermont-Ferrand Cedex (France); Laboratoire de Physique Corpusculaire, CNRS/IN2P3, 63177 Aubiere (France)

    2006-12-15

    Although time consuming, Monte-Carlo simulations remain an efficient tool enabling to assess correction methods for degrading physical effects in medical imaging. We have optimized and validated a reconstruction method baptized F3DMC (Fully 3D Monte Carlo) in which the physical effects degrading the image formation process were modelled using Monte-Carlo methods and integrated within the system matrix. We used the Monte-Carlo simulation toolbox GATE. We validated GATE in SPECT by modelling the gamma-camera (Philips AXIS) used in clinical routine. Techniques of threshold, filtering by a principal component analysis and targeted reconstruction (functional regions, hybrid regions) were used in order to improve the precision of the system matrix and to reduce the number of simulated photons as well as the time consumption required. The EGEE Grid infrastructures were used to deploy the GATE simulations in order to reduce their computation time. Results obtained with F3DMC were compared with the reconstruction methods (FBP, ML-EM, MLEMC) for a simulated phantom and with the OSEM-C method for the real phantom. Results have shown that the F3DMC method and its variants improve the restoration of activity ratios and the signal to noise ratio. By the use of the grid EGEE, a significant speed-up factor of about 300 was obtained. These results should be confirmed by performing studies on complex phantoms and patients and open the door to a unified reconstruction method, which could be used in SPECT and also in PET. (author)

  2. Fully Automatic 3D Reconstruction of Histological Images

    CERN Document Server

    Bagci, Ulas

    2009-01-01

    In this paper, we propose a computational framework for 3D volume reconstruction from 2D histological slices using registration algorithms in feature space. To improve the quality of reconstructed 3D volume, first, intensity variations in images are corrected by an intensity standardization process which maps image intensity scale to a standard scale where similar intensities correspond to similar tissues. Second, a subvolume approach is proposed for 3D reconstruction by dividing standardized slices into groups. Third, in order to improve the quality of the reconstruction process, an automatic best reference slice selection algorithm is developed based on an iterative assessment of image entropy and mean square error of the registration process. Finally, we demonstrate that the choice of the reference slice has a significant impact on registration quality and subsequent 3D reconstruction.

  3. 3D Building Reconstruction Using Dense Photogrammetric Point Cloud

    Science.gov (United States)

    Malihi, S.; Valadan Zoej, M. J.; Hahn, M.; Mokhtarzade, M.; Arefi, H.

    2016-06-01

    Three dimensional models of urban areas play an important role in city planning, disaster management, city navigation and other applications. Reconstruction of 3D building models is still a challenging issue in 3D city modelling. Point clouds generated from multi view images of UAV is a novel source of spatial data, which is used in this research for building reconstruction. The process starts with the segmentation of point clouds of roofs and walls into planar groups. By generating related surfaces and using geometrical constraints plus considering symmetry, a 3d model of building is reconstructed. In a refinement step, dormers are extracted, and their models are reconstructed. The details of the 3d reconstructed model are in LoD3 level, with respect to modelling eaves, fractions of roof and dormers.

  4. A 3D Model Reconstruction Method Using Slice Images

    Institute of Scientific and Technical Information of China (English)

    LI Hong-an; KANG Bao-sheng

    2013-01-01

    Aiming at achieving the high accuracy 3D model from slice images, a new model reconstruction method using slice im-ages is proposed. Wanting to extract the outermost contours from slice images, the method of the improved GVF-Snake model with optimized force field and ray method is employed. And then, the 3D model is reconstructed by contour connection using the im-proved shortest diagonal method and judgment function of contour fracture. The results show that the accuracy of reconstruction 3D model is improved.

  5. ECG gated tomographic reconstruction for 3-D rotational coronary angiography

    Science.gov (United States)

    Hu, Yining; Xie, Lizhe; Nunes, Jean Claude; Bellanger, Jean Jacques; Bedossa, Marc; Toumoulin, Christine

    2010-01-01

    A method is proposed for 3-D reconstruction of coronary from a limited number of projections in rotational angiography. A Bayesian maximum a posteriori (MAP) estimation is applied with a Poisson distributed projection to reconstruct the 3D coronary tree at a given instant of the cardiac cycle. Several regularizers are investigated L0-norm, L1 and L2 -norm in order to take into account the sparsity of the data. Evaluations are reported on simulated data obtained from a 3D dynamic sequence acquired on a 64-slice GE LightSpeed CT scan. A performance study is conducted to evaluate the quality of the reconstruction of the structures. PMID:21096844

  6. Reconstruction of 3-D digital cores using a hybrid method

    Institute of Scientific and Technical Information of China (English)

    Liu Xuefeng; Sun Jianmeng; Wang Haitao

    2009-01-01

    A 3-D digital core describes the pore space microstructure of rocks. An X-ray micro CT scan is the most accurate and direct but costly method to obtain a 3-D digital core. In this study, we propose a hybrid method which combines sedimentation simulation and simulated annealing (SA) method to generate 3-D digital cores based on 2-D images of rocks. The method starts with the sedimentation simulation to build a 3-D digital core, which is the initial configuration for the SA method. We update the initial digital core using the SA method to match the auto-correlation function of the 2-D rock image and eventually build the final 3-D digital core. Compared with the typical SA method, the hybrid method has significantly reduced the computation time. Local porosity theory is applied to quantitatively compare the reconstructed 3-D digital cores with the X-ray micro CT 3-D images. The results indicate that the 3-D digital cores reconstructed by the hybrid method have homogeneity and geometric connectivity similar to those of the X-ray micro CT image. The formation factors and permeabilities of the reconstructed 3-D digital cores are estimated using the finite element method (FEM) and lattice Boltzmann method (LBM), respectively. The simulated results are in good agreement with the experimental measurements. Comparison of the simulation results suggests that the digital cores reconstructed by the hybrid method more closely reflect the true transport properties than the typical SA method alone.

  7. Interior Reconstruction Using the 3d Hough Transform

    Science.gov (United States)

    Dumitru, R.-C.; Borrmann, D.; Nüchter, A.

    2013-02-01

    Laser scanners are often used to create accurate 3D models of buildings for civil engineering purposes, but the process of manually vectorizing a 3D point cloud is time consuming and error-prone (Adan and Huber, 2011). Therefore, the need to characterize and quantify complex environments in an automatic fashion arises, posing challenges for data analysis. This paper presents a system for 3D modeling by detecting planes in 3D point clouds, based on which the scene is reconstructed at a high architectural level through removing automatically clutter and foreground data. The implemented software detects openings, such as windows and doors and completes the 3D model by inpainting.

  8. Application of CT 3D reconstruction in diagnosing atlantoaxial subluxation

    Institute of Scientific and Technical Information of China (English)

    段少银; 林清池; 庞瑞麟

    2004-01-01

    Objective:To evaluate and compare the diagnostic value in atlantoaxial subluxation by CT three-dimensional (3D) reconstruction.Methods:3D reconstruction fimdings of 41 patients with atlantoaxiai subluxation were retrospectively analyzed, and comparisons were made among images of transverse section, multiplanar reformorting (MPR), surface shade display (SSD), maximum intensity project (MIP), and volume rendering (VR). Results:Of 41 patients with atlantoaxial subluxation, 31 belonged to rotary dislocation, 5 antedislocation, and 5 hind dislocation. All the cases showed the dislocated joint panel of atlantoaxial articulation.Fifteen cases showed deviation of the odontoid process and 8 cases widened distance between the dens and anterior arch of the atlas. The dislocated joint panel of atlantoaxial articulation was more clearly seen with SSD-3D imaging than any other methods. Conclusions:Atlantoaxial subluxation can well be diagnosed by CT 3D reconstruction, in which SSD-3D imaging is optimal.

  9. Array antenna diagnostics with the 3D reconstruction algorithm

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Meincke, Peter; Pivnenko, Sergey;

    2012-01-01

    The 3D reconstruction algorithm is applied to a slotted waveguide array measured at the DTU-ESA Spherical Near-Field Antenna Test Facility. One slot of the array is covered by conductive tape and an error is present in the array excitation. Results show the accuracy obtainable by the 3D...

  10. Stereo Based 3D Face Reconstruction

    OpenAIRE

    Falešník, Milan

    2013-01-01

    Tato práce se zabývá vytvořením programu pro rekonstrukc trojrozměrného modelu lidské tváře za pomocí dvojice kamer. Pro řešení využívá výpočtu hloubkové mapy a následný převod do trojrozměrného prostoru. Využívá Viola-Jones detektor pro detekci tváře. Využívá knihovny OpenCV a také částečně PCL. This thesis presents a system for reconstruction of three-dimensional model of human face by using pair of cameras. To solve this problem, depth map calculation is used and then the depth map is t...

  11. 3D electron tomography of biological photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Butz, Benjamin; Winter, Benjamin; Vieweg, Benito; Knoke, Isabel; Spallek, Stefanie; Spiecker, Erdmann [CENEM, Universitaet Erlangen-Nuernberg (Germany); Schroeder-Turk, Gerd; Mecke, Klaus [Theoretische Physik I, Universitaet Erlangen-Nuernberg (Germany)

    2011-07-01

    Photonic crystals, i.e. periodical nanostructures of materials with different dielectric constants, are highly interesting for applications in optics, optoelectronics, and sensing. By tailoring the geometrical parameters radically different and improved optical properties (e.g., optical band-gap structure, extreme refractive indices, or high anisotropy) can be achieved. Naturally occurring photonic crystals, like butterfly scales, exoskeletons of insects (chitin), or seashells (nacre), can serve as model systems for understanding the relationship between structure and optical properties. Butterfly scales are studied by TEM using a FEI Titan{sup 3} 80-300 instrument. An optimized FIB technique or ultramicrotome sectioning were used to prepare the sensitive specimens with desired thickness. Since the periodical structures have dimensions on the sub-{mu}m scale, HAADF-STEM tomography was employed for obtaining extended tilt series under conditions of atomic-number sensitive imaging. Since the solid crystal consists of chemically homogeneous chitin while the pores are unfilled, the distinct contrast in the images can easily be interpreted in terms of the local projected mass density allowing to reconstruct the chitin distribution within the optical unit cell of the scales with high 3D resolution.

  12. Reconstruction of High Resolution 3D Objects from Incomplete Images and 3D Information

    Directory of Open Access Journals (Sweden)

    Alexander Pacheco

    2014-05-01

    Full Text Available To this day, digital object reconstruction is a quite complex area that requires many techniques and novel approaches, in which high-resolution 3D objects present one of the biggest challenges. There are mainly two different methods that can be used to reconstruct high resolution objects and images: passive methods and active methods. This methods depend on the type of information available as input for modeling 3D objects. The passive methods use information contained in the images and the active methods make use of controlled light sources, such as lasers. The reconstruction of 3D objects is quite complex and there is no unique solution- The use of specific methodologies for the reconstruction of certain objects it’s also very common, such as human faces, molecular structures, etc. This paper proposes a novel hybrid methodology, composed by 10 phases that combine active and passive methods, using images and a laser in order to supplement the missing information and obtain better results in the 3D object reconstruction. Finally, the proposed methodology proved its efficiency in two complex topological complex objects.

  13. A new algorithm for 3D reconstruction from support functions

    DEFF Research Database (Denmark)

    Gardner, Richard; Kiderlen, Markus

    2009-01-01

    We introduce a new algorithm for reconstructing an unknown shape from a finite number of noisy measurements of its support function. The algorithm, based on a least squares procedure, is very easy to program in standard software such as Matlab and allows, for the first time, good 3D reconstructions...

  14. Filtering of measurement noise with the 3D reconstruction algorithm

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Pivnenko, Sergey

    2014-01-01

    Two different antenna models are set up in GRASP and CHAMP, and noise is added to the radiated field. The noisy field is then given as input to the 3D reconstruction of DIATOOL and the SWE coefficients and the far-field radiated by the reconstructed currents are compared with the noise-free results...

  15. Light field display and 3D image reconstruction

    Science.gov (United States)

    Iwane, Toru

    2016-06-01

    Light field optics and its applications become rather popular in these days. With light field optics or light field thesis, real 3D space can be described in 2D plane as 4D data, which we call as light field data. This process can be divided in two procedures. First, real3D scene is optically reduced with imaging lens. Second, this optically reduced 3D image is encoded into light field data. In later procedure we can say that 3D information is encoded onto a plane as 2D data by lens array plate. This transformation is reversible and acquired light field data can be decoded again into 3D image with the arrayed lens plate. "Refocusing" (focusing image on your favorite point after taking a picture), light-field camera's most popular function, is some kind of sectioning process from encoded 3D data (light field data) to 2D image. In this paper at first I show our actual light field camera and our 3D display using acquired and computer-simulated light field data, on which real 3D image is reconstructed. In second I explain our data processing method whose arithmetic operation is performed not in Fourier domain but in real domain. Then our 3D display system is characterized by a few features; reconstructed image is of finer resolutions than density of arrayed lenses and it is not necessary to adjust lens array plate to flat display on which light field data is displayed.

  16. Improving automated 3D reconstruction methods via vision metrology

    Science.gov (United States)

    Toschi, Isabella; Nocerino, Erica; Hess, Mona; Menna, Fabio; Sargeant, Ben; MacDonald, Lindsay; Remondino, Fabio; Robson, Stuart

    2015-05-01

    This paper aims to provide a procedure for improving automated 3D reconstruction methods via vision metrology. The 3D reconstruction problem is generally addressed using two different approaches. On the one hand, vision metrology (VM) systems try to accurately derive 3D coordinates of few sparse object points for industrial measurement and inspection applications; on the other, recent dense image matching (DIM) algorithms are designed to produce dense point clouds for surface representations and analyses. This paper strives to demonstrate a step towards narrowing the gap between traditional VM and DIM approaches. Efforts are therefore intended to (i) test the metric performance of the automated photogrammetric 3D reconstruction procedure, (ii) enhance the accuracy of the final results and (iii) obtain statistical indicators of the quality achieved in the orientation step. VM tools are exploited to integrate their main functionalities (centroid measurement, photogrammetric network adjustment, precision assessment, etc.) into the pipeline of 3D dense reconstruction. Finally, geometric analyses and accuracy evaluations are performed on the raw output of the matching (i.e. the point clouds) by adopting a metrological approach. The latter is based on the use of known geometric shapes and quality parameters derived from VDI/VDE guidelines. Tests are carried out by imaging the calibrated Portable Metric Test Object, designed and built at University College London (UCL), UK. It allows assessment of the performance of the image orientation and matching procedures within a typical industrial scenario, characterised by poor texture and known 3D/2D shapes.

  17. Parallel OSEM Reconstruction Algorithm for Fully 3-D SPECT on a Beowulf Cluster.

    Science.gov (United States)

    Rong, Zhou; Tianyu, Ma; Yongjie, Jin

    2005-01-01

    In order to improve the computation speed of ordered subset expectation maximization (OSEM) algorithm for fully 3-D single photon emission computed tomography (SPECT) reconstruction, an experimental beowulf-type cluster was built and several parallel reconstruction schemes were described. We implemented a single-program-multiple-data (SPMD) parallel 3-D OSEM reconstruction algorithm based on message passing interface (MPI) and tested it with combinations of different number of calculating processors and different size of voxel grid in reconstruction (64×64×64 and 128×128×128). Performance of parallelization was evaluated in terms of the speedup factor and parallel efficiency. This parallel implementation methodology is expected to be helpful to make fully 3-D OSEM algorithms more feasible in clinical SPECT studies.

  18. Rapidly 3D Texture Reconstruction Based on Oblique Photography

    Directory of Open Access Journals (Sweden)

    ZHANG Chunsen

    2015-07-01

    Full Text Available This paper proposes a city texture fast reconstruction method based on aerial tilt image for reconstruction of three-dimensional city model. Based on the photogrammetry and computer vision theory and using the city building digital surface model obtained by prior treatment, through collinear equation calculation geometric projection of object and image space, to obtain the three-dimensional information and texture information of the structure and through certain the optimal algorithm selecting the optimal texture on the surface of the object, realize automatic extraction of the building side texture and occlusion handling of the dense building texture. The real image texture reconstruction results show that: the method to the 3D city model texture reconstruction has the characteristics of high degree of automation, vivid effect and low cost and provides a means of effective implementation for rapid and widespread real texture rapid reconstruction of city 3D model.

  19. Preoperative Planning Using 3D Reconstructions and Virtual Endoscopy for Location of the Frontal Sinus

    Directory of Open Access Journals (Sweden)

    Abreu, João Paulo Saraiva

    2011-01-01

    Full Text Available Introduction: Computed tomography (TC generated tridimensional (3D reconstructions allow the observation of cavities and anatomic structures of our body with detail. In our specialty there have been attempts to carry out virtual endoscopies and laryngoscopies. However, such application has been practically abandoned due to its complexity and need for computers with high power of graphic processing. Objective: To demonstrate the production of 3D reconstructions from CTs of patients in personal computers, with a free specific program and compare them to the surgery actual endoscopic images. Method: Prospective study in which the CTs proper files of 10 patients were reconstructed with the program Intage Realia, version 2009, 0, 0, 702 (KGT Inc., Japan. The reconstructions were carried out before the surgeries and a virtual endoscopy was made to assess the recess and frontal sinus region. After this study, the surgery was digitally performed and stored. The actual endoscopic images of the recess and frontal sinus region were compared to the virtual images. Results: The 3D reconstruction and virtual endoscopy were made in 10 patients submitted to the surgery. The virtual images had a large resemblance with the actual surgical images. Conclusion: With relatively simple tools and personal computer, we demonstrated the possibility to generate 3D reconstructions and virtual endoscopies. The preoperative knowledge of the frontal sinus natural draining path location may generate benefits during the performance of surgeries. However, more studies must be developed for the evaluation of the real roles of such 3D reconstructions and virtual endoscopies.

  20. Building with Drones: Accurate 3D Facade Reconstruction using MAVs

    OpenAIRE

    Daftry, Shreyansh; Hoppe, Christof; Bischof, Horst

    2015-01-01

    Automatic reconstruction of 3D models from images using multi-view Structure-from-Motion methods has been one of the most fruitful outcomes of computer vision. These advances combined with the growing popularity of Micro Aerial Vehicles as an autonomous imaging platform, have made 3D vision tools ubiquitous for large number of Architecture, Engineering and Construction applications among audiences, mostly unskilled in computer vision. However, to obtain high-resolution and accurate reconstruc...

  1. 3D surface reconstruction multi-scale hierarchical approaches

    CERN Document Server

    Bellocchio, Francesco; Ferrari, Stefano; Piuri, Vincenzo

    2012-01-01

    3D Surface Reconstruction: Multi-Scale Hierarchical Approaches presents methods to model 3D objects in an incremental way so as to capture more finer details at each step. The configuration of the model parameters, the rationale and solutions are described and discussed in detail so the reader has a strong understanding of the methodology. Modeling starts from data captured by 3D digitizers and makes the process even more clear and engaging. Innovative approaches, based on two popular machine learning paradigms, namely Radial Basis Functions and the Support Vector Machines, are also introduced

  2. 3D reconstruction based on spatial vanishing information

    Institute of Scientific and Technical Information of China (English)

    Yuan Shu; Zheng Tan

    2005-01-01

    An approach for the three-dimensional (3D) reconstruction of architectural scenes from two un-calibrated images is described in this paper. From two views of one architectural structure, three pairs of corresponding vanishing points of three major mutual orthogonal directions can be extracted. The simple but powerful constraints of parallelism and orthogonal lines in architectural scenes can be used to calibrate the cameras and to recover the 3D information of the structure. This approach is applied to the real images of architectural scenes, and a 3D model of a building in virtual reality modelling language (VRML) format is presented which illustrates the method with successful performance.

  3. 3D Observation of GEMS by Electron Tomography

    Science.gov (United States)

    Matsuno, Junya; Miyake, Akira; Tsuchiyama, Akira; Nakamura-Messenger, Keiko; Messenger, Scott

    2014-01-01

    Amorphous silicates in chondritic porous interplanetary dust particles (CP-IDPs) coming from comets are dominated by glass with embedded metal and sulfides (GEMS). GEMS grains are submicron-sized rounded objects (typically 100-500) nm in diameter) with anaometer-sized (10-50 nm) Fe-Ni metal and sulfide grains embedded in an amorphous silicate matrix. Several formation processes for GEMS grains have been proposed so far, but these models are still being debated [2-5]. Bradley et al. proposed that GEMS grains are interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk and that they are amorphiation products of crystalline silicates in the interstellar medium by sputter-deposition of cosmic ray irradiation, similar to space weathering [2,4]. This consideration is based on the observation of nano-sized crystals (approximately 10 nm) called relict grains in GEMS grains and their shapes are pseudomorphs to the host GEMS grains. On the other hand, Keller and Messenger proposed that most GEMS formed in the protoplanetary disk as condensates from high temperature gas [3,5]. This model is based on the fact that most GEMS grains have solar isotopic compositions and have extremely heterogeneous and non-solar elemental compositions. Keller and Messenger (2011) also reported that amorphous silicates in GEMS grains are surrounded by sulfide grains, which formed as sulfidization of metallic iron grains located on the GEMS surface. The previous studies were performed with 2D observation by using transmission electron microscopy (TEM) or scanning TEM (STEM). In order to understand the structure of GEMS grains described above more clearly, we observed 3D structure of GEMS grains by electron tomography using a TEM/STEM (JEM-2100F, JEOL) at Kyoto University. Electron tomography gives not only 3D structures but also gives higher spatial resolution (approximately a few nm) than that in conventional 2D image, which is restricted by

  4. New Reconstruction Accuracy Metric for 3D PIV

    Science.gov (United States)

    Bajpayee, Abhishek; Techet, Alexandra

    2015-11-01

    Reconstruction for 3D PIV typically relies on recombining images captured from different viewpoints via multiple cameras/apertures. Ideally, the quality of reconstruction dictates the accuracy of the derived velocity field. A reconstruction quality parameter Q is commonly used as a measure of the accuracy of reconstruction algorithms. By definition, a high Q value requires intensity peak levels and shapes in the reconstructed and reference volumes to be matched. We show that accurate velocity fields rely only on the peak locations in the volumes and not on intensity peak levels and shapes. In synthetic aperture (SA) PIV reconstructions, the intensity peak shapes and heights vary with the number of cameras and due to spatial/temporal particle intensity variation respectively. This lowers Q but not the accuracy of the derived velocity field. We introduce a new velocity vector correlation factor Qv as a metric to assess the accuracy of 3D PIV techniques, which provides a better indication of algorithm accuracy. For SAPIV, the number of cameras required for a high Qv are lower than that for a high Q. We discuss Qv in the context of 3D PIV and also present a preliminary comparison of the performance of TomoPIV and SAPIV based on Qv.

  5. 3D Reconstruction of Human Motion from Monocular Image Sequences.

    Science.gov (United States)

    Wandt, Bastian; Ackermann, Hanno; Rosenhahn, Bodo

    2016-08-01

    This article tackles the problem of estimating non-rigid human 3D shape and motion from image sequences taken by uncalibrated cameras. Similar to other state-of-the-art solutions we factorize 2D observations in camera parameters, base poses and mixing coefficients. Existing methods require sufficient camera motion during the sequence to achieve a correct 3D reconstruction. To obtain convincing 3D reconstructions from arbitrary camera motion, our method is based on a-priorly trained base poses. We show that strong periodic assumptions on the coefficients can be used to define an efficient and accurate algorithm for estimating periodic motion such as walking patterns. For the extension to non-periodic motion we propose a novel regularization term based on temporal bone length constancy. In contrast to other works, the proposed method does not use a predefined skeleton or anthropometric constraints and can handle arbitrary camera motion. We achieve convincing 3D reconstructions, even under the influence of noise and occlusions. Multiple experiments based on a 3D error metric demonstrate the stability of the proposed method. Compared to other state-of-the-art methods our algorithm shows a significant improvement.

  6. 3D Reconstruction of Human Motion from Monocular Image Sequences.

    Science.gov (United States)

    Wandt, Bastian; Ackermann, Hanno; Rosenhahn, Bodo

    2016-08-01

    This article tackles the problem of estimating non-rigid human 3D shape and motion from image sequences taken by uncalibrated cameras. Similar to other state-of-the-art solutions we factorize 2D observations in camera parameters, base poses and mixing coefficients. Existing methods require sufficient camera motion during the sequence to achieve a correct 3D reconstruction. To obtain convincing 3D reconstructions from arbitrary camera motion, our method is based on a-priorly trained base poses. We show that strong periodic assumptions on the coefficients can be used to define an efficient and accurate algorithm for estimating periodic motion such as walking patterns. For the extension to non-periodic motion we propose a novel regularization term based on temporal bone length constancy. In contrast to other works, the proposed method does not use a predefined skeleton or anthropometric constraints and can handle arbitrary camera motion. We achieve convincing 3D reconstructions, even under the influence of noise and occlusions. Multiple experiments based on a 3D error metric demonstrate the stability of the proposed method. Compared to other state-of-the-art methods our algorithm shows a significant improvement. PMID:27093439

  7. Automated 3D reconstruction of interiors with multiple scan views

    Science.gov (United States)

    Sequeira, Vitor; Ng, Kia C.; Wolfart, Erik; Goncalves, Joao G. M.; Hogg, David C.

    1998-12-01

    This paper presents two integrated solutions for realistic 3D model acquisition and reconstruction; an early prototype, in the form of a push trolley, and a later prototype in the form of an autonomous robot. The systems encompass all hardware and software required, from laser and video data acquisition, processing and output of texture-mapped 3D models in VRML format, to batteries for power supply and wireless network communications. The autonomous version is also equipped with a mobile platform and other sensors for the purpose of automatic navigation. The applications for such a system range from real estate and tourism (e.g., showing a 3D computer model of a property to a potential buyer or tenant) or as tool for content creation (e.g., creating 3D models of heritage buildings or producing broadcast quality virtual studios). The system can also be used in industrial environments as a reverse engineering tool to update the design of a plant, or as a 3D photo-archive for insurance purposes. The system is Internet compatible: the photo-realistic models can be accessed via the Internet and manipulated interactively in 3D using a common Web browser with a VRML plug-in. Further information and example reconstructed models are available on- line via the RESOLV web-page at http://www.scs.leeds.ac.uk/resolv/.

  8. [Customized 3D radiographic reconstruction of the human pelvis].

    Science.gov (United States)

    Gauvin, C; Dansereau, J; Petit, Y; De Guise, J A; Labelle, H

    1998-01-01

    The pelvis is an essential element in the study of scoliosis since it constitutes the base of the spine and its orientation may affects postural balance. In order to study the role of the pelvis in the evolution and treatment of this disease, a new technique for the 3D personalised reconstruction of the pelvis was developed. It consists in identifying and digitizing 19 pelvic anatomical landmarks on postero-anterior and lateral x-rays and to reconstruct them in 3D with two techniques: the DLT algorithm developed by Marzan (1976) and, for 6 of the 19 landmarks, an adaptation of it called DLT with confidence coefficients. The latter takes into account the confidence given to the identification of the landmarks on each x-rays. Two methods were used to validate the reconstruction of the pelvis. The first one, used for 11 scoliotic patients and 2 dry pelvis specimens, consists in applying the reconstruction algorithm in an inverse way on the 3D coordinates of the reconstructed landmarks to obtain their 2D retroprojection on the x-ray planes, and thus comparing the retroprojected coordinates with the 2D digitized coordinates. The second method consists in measuring a dry pelvis specimen and comparing the 3D measured landmarks with the ones reconstructed with the x-rays of this specimen. For the first validation, results have shown that the lowest retroprojection errors (less than 2.5 +/- 2.6 mm) for the scoliotic patient group are located on the superior base of the sacrum, on the sacral curve and on the acetabula, while the highest (6.4 +/- 7.2 mm) were on the iliac crests. For the dry specimens, the retroprojection errors were below the millimeter. The second validation method showed 3D differences of 2.4 +/- 1.2 mm between measured and reconstructed landmarks of a dry specimen, which is of the same order of magnitude as what is reported in the literature for vertebrae. The reconstruction of the pelvis is thus considered adequate and its graphical wireframe

  9. Recent advances in 3D SEM surface reconstruction.

    Science.gov (United States)

    Tafti, Ahmad P; Kirkpatrick, Andrew B; Alavi, Zahrasadat; Owen, Heather A; Yu, Zeyun

    2015-11-01

    The scanning electron microscope (SEM), as one of the most commonly used instruments in biology and material sciences, employs electrons instead of light to determine the surface properties of specimens. However, the SEM micrographs still remain 2D images. To effectively measure and visualize the surface attributes, we need to restore the 3D shape model from the SEM images. 3D surface reconstruction is a longstanding topic in microscopy vision as it offers quantitative and visual information for a variety of applications consisting medicine, pharmacology, chemistry, and mechanics. In this paper, we attempt to explain the expanding body of the work in this area, including a discussion of recent techniques and algorithms. With the present work, we also enhance the reliability, accuracy, and speed of 3D SEM surface reconstruction by designing and developing an optimized multi-view framework. We then consider several real-world experiments as well as synthetic data to examine the qualitative and quantitative attributes of our proposed framework. Furthermore, we present a taxonomy of 3D SEM surface reconstruction approaches and address several challenging issues as part of our future work.

  10. 3D reconstruction of multiple stained histology images

    Directory of Open Access Journals (Sweden)

    Yi Song

    2013-01-01

    Full Text Available Context: Three dimensional (3D tissue reconstructions from the histology images with different stains allows the spatial alignment of structural and functional elements highlighted by different stains for quantitative study of many physiological and pathological phenomena. This has significant potential to improve the understanding of the growth patterns and the spatial arrangement of diseased cells, and enhance the study of biomechanical behavior of the tissue structures towards better treatments (e.g. tissue-engineering applications. Methods: This paper evaluates three strategies for 3D reconstruction from sets of two dimensional (2D histological sections with different stains, by combining methods of 2D multi-stain registration and 3D volumetric reconstruction from same stain sections. Setting and Design: The different strategies have been evaluated on two liver specimens (80 sections in total stained with Hematoxylin and Eosin (H and E, Sirius Red, and Cytokeratin (CK 7. Results and Conclusion: A strategy of using multi-stain registration to align images of a second stain to a volume reconstructed by same-stain registration results in the lowest overall error, although an interlaced image registration approach may be more robust to poor section quality.

  11. Deformable Surface 3D Reconstruction from Monocular Images

    CERN Document Server

    Salzmann, Matthieu

    2010-01-01

    Being able to recover the shape of 3D deformable surfaces from a single video stream would make it possible to field reconstruction systems that run on widely available hardware without requiring specialized devices. However, because many different 3D shapes can have virtually the same projection, such monocular shape recovery is inherently ambiguous. In this survey, we will review the two main classes of techniques that have proved most effective so far: The template-based methods that rely on establishing correspondences with a reference image in which the shape is already known, and non-rig

  12. 3D X-ray microscopy: image formation, tomography and instrumentation

    OpenAIRE

    Selin, Mårten

    2016-01-01

    Tomography in soft X-ray microscopy is an emerging technique for obtaining quantitative 3D structural information about cells. One of its strengths, compared with other techniques, is that it can image intact cells in their near-native state at a few 10 nm’s resolution, without staining. However, the methods for reconstructing 3D-data rely on algorithms that assume projection data, which the images are generally not due to the imaging systems’ limited depth of focus. To bring out the full pot...

  13. Reconstruction of 3D morphology of polyhedral nanoparticles

    International Nuclear Information System (INIS)

    The three-dimensional (3D) faceting morphology of ceria nanoparticles is analysed using transmission electron microscopy (TEM)-based computed tomography on the nanometre scale. A novel tomography mode of electron energy loss spectroscopic imaging using a single energy window for inelastically scattered electrons is introduced and found to be reliable and fast for freestanding nanoparticles. To compare the new tomographic method with other methods, we provide the first comprehensive application of three complementary TEM-based imaging techniques, including bright field TEM and annular dark field specific TEM (STEM). Traditional bright-field TEM tomography is found to be applicable, in spite of obvious artefacts, for crystalline particles of constant composition. However, the safest interpretation is achieved by a combined recording of bright field and spectroscopic images

  14. Low contrast 3D reconstruction from C-arm data

    Science.gov (United States)

    Zellerhoff, M.; Scholz, B.; Ruehrnschopf, E.-P.; Brunner, T.

    2005-04-01

    The integration of 3D-imaging functionality into C-arm systems combines advantages of interventional X-ray systems, e.g. good patient access and live fluoroscopy, with 3D imaging capabilities similar to those of a CT-scanner. To date 3D-imaging with a C-arm system has been mainly used to visualize high contrast objects. However, the advent of high quality flat panel detectors improves the low contrast imaging capabilities. We discuss the influence of scattered radiation, beam hardening, truncated projections, quantization and detector recording levels on the image quality. Subsequently, we present algorithms and methods to correct these effects in order to achieve low contrast resolution. The performance of our pre- and post-reconstructive correction procedures is demonstrated by first clinical cases.

  15. Twenty-fold acceleration of 3D projection reconstruction MPI

    OpenAIRE

    Konkle, Justin J.; Goodwill, Patrick W.; Saritas, Emine Ulku; Zheng, Bo; Lu, Kuan; Conolly, Steven M.

    2013-01-01

    We experimentally demonstrate a 20-fold improvement in acquisition time in projection reconstruction (PR) magnetic particle imaging (MPI) relative to the state-of-the-art PR MPI imaging results. We achieve this acceleration in our imaging system by introducing an additional Helmholtz electromagnet pair, which creates a slow shift (focus) field. Because of magnetostimulation limits in humans, we show that scan time with three-dimensional (3D) PR MPI is theoretically within the same order of ma...

  16. 3DSEM++: Adaptive and intelligent 3D SEM surface reconstruction.

    Science.gov (United States)

    Tafti, Ahmad P; Holz, Jessica D; Baghaie, Ahmadreza; Owen, Heather A; He, Max M; Yu, Zeyun

    2016-08-01

    Structural analysis of microscopic objects is a longstanding topic in several scientific disciplines, such as biological, mechanical, and materials sciences. The scanning electron microscope (SEM), as a promising imaging equipment has been around for decades to determine the surface properties (e.g., compositions or geometries) of specimens by achieving increased magnification, contrast, and resolution greater than one nanometer. Whereas SEM micrographs still remain two-dimensional (2D), many research and educational questions truly require knowledge and facts about their three-dimensional (3D) structures. 3D surface reconstruction from SEM images leads to remarkable understanding of microscopic surfaces, allowing informative and qualitative visualization of the samples being investigated. In this contribution, we integrate several computational technologies including machine learning, contrario methodology, and epipolar geometry to design and develop a novel and efficient method called 3DSEM++ for multi-view 3D SEM surface reconstruction in an adaptive and intelligent fashion. The experiments which have been performed on real and synthetic data assert the approach is able to reach a significant precision to both SEM extrinsic calibration and its 3D surface modeling.

  17. 3DSEM++: Adaptive and intelligent 3D SEM surface reconstruction.

    Science.gov (United States)

    Tafti, Ahmad P; Holz, Jessica D; Baghaie, Ahmadreza; Owen, Heather A; He, Max M; Yu, Zeyun

    2016-08-01

    Structural analysis of microscopic objects is a longstanding topic in several scientific disciplines, such as biological, mechanical, and materials sciences. The scanning electron microscope (SEM), as a promising imaging equipment has been around for decades to determine the surface properties (e.g., compositions or geometries) of specimens by achieving increased magnification, contrast, and resolution greater than one nanometer. Whereas SEM micrographs still remain two-dimensional (2D), many research and educational questions truly require knowledge and facts about their three-dimensional (3D) structures. 3D surface reconstruction from SEM images leads to remarkable understanding of microscopic surfaces, allowing informative and qualitative visualization of the samples being investigated. In this contribution, we integrate several computational technologies including machine learning, contrario methodology, and epipolar geometry to design and develop a novel and efficient method called 3DSEM++ for multi-view 3D SEM surface reconstruction in an adaptive and intelligent fashion. The experiments which have been performed on real and synthetic data assert the approach is able to reach a significant precision to both SEM extrinsic calibration and its 3D surface modeling. PMID:27200484

  18. An automated 3D reconstruction method of UAV images

    Science.gov (United States)

    Liu, Jun; Wang, He; Liu, Xiaoyang; Li, Feng; Sun, Guangtong; Song, Ping

    2015-10-01

    In this paper a novel fully automated 3D reconstruction approach based on low-altitude unmanned aerial vehicle system (UAVs) images will be presented, which does not require previous camera calibration or any other external prior knowledge. Dense 3D point clouds are generated by integrating orderly feature extraction, image matching, structure from motion (SfM) and multi-view stereo (MVS) algorithms, overcoming many of the cost, time limitations of rigorous photogrammetry techniques. An image topology analysis strategy is introduced to speed up large scene reconstruction by taking advantage of the flight-control data acquired by UAV. Image topology map can significantly reduce the running time of feature matching by limiting the combination of images. A high-resolution digital surface model of the study area is produced base on UAV point clouds by constructing the triangular irregular network. Experimental results show that the proposed approach is robust and feasible for automatic 3D reconstruction of low-altitude UAV images, and has great potential for the acquisition of spatial information at large scales mapping, especially suitable for rapid response and precise modelling in disaster emergency.

  19. Projective 3D-reconstruction of Uncalibrated Endoscopic Images

    Directory of Open Access Journals (Sweden)

    P. Faltin

    2010-01-01

    Full Text Available The most common medical diagnostic method for urinary bladder cancer is cystoscopy. This inspection of the bladder is performed by a rigid endoscope, which is usually guided close to the bladder wall. This causes a very limited field of view; difficulty of navigation is aggravated by the usage of angled endoscopes. These factors cause difficulties in orientation and visual control. To overcome this problem, the paper presents a method for extracting 3D information from uncalibrated endoscopic image sequences and for reconstructing the scene content. The method uses the SURF-algorithm to extract features from the images and relates the images by advanced matching. To stabilize the matching, the epipolar geometry is extracted for each image pair using a modified RANSAC-algorithm. Afterwards these matched point pairs are used to generate point triplets over three images and to describe the trifocal geometry. The 3D scene points are determined by applying triangulation to the matched image points. Thus, these points are used to generate a projective 3D reconstruction of the scene, and provide the first step for further metric reconstructions.

  20. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner...... providing a reference system for measurement. The artefact allows a considerable reduction of time by compressing the full process of calibration, scanning, measurement, and re-calibration, into a single process. The method allows a considerable reduction of the amount of data generated from CT scanning...

  1. 3D Cone Beam Volumetric Tomography Dedicated to Maxillofacial Radiology

    OpenAIRE

    Masoud Varshosaz

    2009-01-01

      "nThe 3D cone beam volume/computed tomography (CBVT/CBCT) has been designed for imaging the hard tissues of the maxillofacial region, although it has been used in some era of medical imaging for many years. CBVT is capable of providing a sub-millimeter resolution with the short scanning time of mostly less than 20 seconds and radiation dosages reportedly up to 15 times lower than those of spiral CT scans. In less than a decade, CBVT has revolutionized oral and maxillofacial ra...

  2. Applicability of 3D-CT facial reconstruction for forensic individual identification

    International Nuclear Information System (INIS)

    Computed tomography (CT) is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT). The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using cranio metric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering technique with computer graphics tools. Ten (10) cranio metric measurements were determined in 3D-CT images by two examiners independently, twice each, and the standard error of intra- and inter-examiner measurements was assessed. The results demonstrated a low standard error of those measurements, from 0.85% to 3.09%. In conclusion, the linear measurements obtained in osseous and soft tissue structures were considered to be precise in 3D-CT with high imaging quality and resolution. (author)

  3. Applicability of 3D-CT facial reconstruction for forensic individual identification

    Directory of Open Access Journals (Sweden)

    Rocha Sara dos Santos

    2003-01-01

    Full Text Available Computed tomography (CT is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT. The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using craniometric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering technique with computer graphics tools. Ten (10 craniometric measurements were determined in 3D-CT images by two examiners independently, twice each, and the standard error of intra- and inter-examiner measurements was assessed. The results demonstrated a low standard error of those measurements, from 0.85% to 3.09%. In conclusion, the linear measurements obtained in osseous and soft tissue structures were considered to be precise in 3D-CT with high imaging quality and resolution.

  4. Applicability of 3D-CT facial reconstruction for forensic individual identification.

    Science.gov (United States)

    Rocha, Sara dos Santos; Ramos, Dalton Luiz; Cavalcanti, Marcelo de Gusmão Paraíso

    2003-01-01

    Computed tomography (CT) is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT). The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using craniometric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering technique with computer graphics tools. Ten (10) craniometric measurements were determined in 3D-CT images by two examiners independently, twice each, and the standard error of intra- and inter-examiner measurements was assessed. The results demonstrated a low standard error of those measurements, from 0.85% to 3.09%. In conclusion, the linear measurements obtained in osseous and soft tissue structures were considered to be precise in 3D-CT with high imaging quality and resolution.

  5. Applicability of 3D-CT facial reconstruction for forensic individual identification

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Sara dos Santos [Sao Paulo Univ., SP (Brazil). Odontologia Forense; Ramos, Dalton Luiz de Paula [Sao Paulo Univ., SP (Brazil). Dept. of Odontologia Social; Cavalcanti, Marcelo de Gusmao Paraiso [Sao Paulo Univ., SP (Brazil). Dept. de Radiologia

    2003-03-01

    Computed tomography (CT) is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT). The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using cranio metric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering technique with computer graphics tools. Ten (10) cranio metric measurements were determined in 3D-CT images by two examiners independently, twice each, and the standard error of intra- and inter-examiner measurements was assessed. The results demonstrated a low standard error of those measurements, from 0.85% to 3.09%. In conclusion, the linear measurements obtained in osseous and soft tissue structures were considered to be precise in 3D-CT with high imaging quality and resolution. (author)

  6. 3D Human cartilage surface characterization by optical coherence tomography

    Science.gov (United States)

    Brill, Nicolai; Riedel, Jörn; Schmitt, Robert; Tingart, Markus; Truhn, Daniel; Pufe, Thomas; Jahr, Holger; Nebelung, Sven

    2015-10-01

    Early diagnosis and treatment of cartilage degeneration is of high clinical interest. Loss of surface integrity is considered one of the earliest and most reliable signs of degeneration, but cannot currently be evaluated objectively. Optical Coherence Tomography (OCT) is an arthroscopically available light-based non-destructive real-time imaging technology that allows imaging at micrometre resolutions to millimetre depths. As OCT-based surface evaluation standards remain to be defined, the present study investigated the diagnostic potential of 3D surface profile parameters in the comprehensive evaluation of cartilage degeneration. To this end, 45 cartilage samples of different degenerative grades were obtained from total knee replacements (2 males, 10 females; mean age 63.8 years), cut to standard size and imaged using a spectral-domain OCT device (Thorlabs, Germany). 3D OCT datasets of 8  ×  8, 4  ×  4 and 1  ×  1 mm (width  ×  length) were obtained and pre-processed (image adjustments, morphological filtering). Subsequent automated surface identification algorithms were used to obtain the 3D primary profiles, which were then filtered and processed using established algorithms employing ISO standards. The 3D surface profile thus obtained was used to calculate a set of 21 3D surface profile parameters, i.e. height (e.g. Sa), functional (e.g. Sk), hybrid (e.g. Sdq) and segmentation-related parameters (e.g. Spd). Samples underwent reference histological assessment according to the Degenerative Joint Disease classification. Statistical analyses included calculation of Spearman’s rho and assessment of inter-group differences using the Kruskal Wallis test. Overall, the majority of 3D surface profile parameters revealed significant degeneration-dependent differences and correlations with the exception of severe end-stage degeneration and were of distinct diagnostic value in the assessment of surface integrity. None of the 3D

  7. 3D Reconstruction of Coronary Artery Vascular Smooth Muscle Cells.

    Directory of Open Access Journals (Sweden)

    Tong Luo

    Full Text Available The 3D geometry of individual vascular smooth muscle cells (VSMCs, which are essential for understanding the mechanical function of blood vessels, are currently not available. This paper introduces a new 3D segmentation algorithm to determine VSMC morphology and orientation.A total of 112 VSMCs from six porcine coronary arteries were used in the analysis. A 3D semi-automatic segmentation method was developed to reconstruct individual VSMCs from cell clumps as well as to extract the 3D geometry of VSMCs. A new edge blocking model was introduced to recognize cell boundary while an edge growing was developed for optimal interpolation and edge verification. The proposed methods were designed based on Region of Interest (ROI selected by user and interactive responses of limited key edges. Enhanced cell boundary features were used to construct the cell's initial boundary for further edge growing. A unified framework of morphological parameters (dimensions and orientations was proposed for the 3D volume data. Virtual phantom was designed to validate the tilt angle measurements, while other parameters extracted from 3D segmentations were compared with manual measurements to assess the accuracy of the algorithm. The length, width and thickness of VSMCs were 62.9±14.9 μm, 4.6±0.6 μm and 6.2±1.8 μm (mean±SD. In longitudinal-circumferential plane of blood vessel, VSMCs align off the circumferential direction with two mean angles of -19.4±9.3° and 10.9±4.7°, while an out-of-plane angle (i.e., radial tilt angle was found to be 8±7.6° with median as 5.7°.A 3D segmentation algorithm was developed to reconstruct individual VSMCs of blood vessel walls based on optical image stacks. The results were validated by a virtual phantom and manual measurement. The obtained 3D geometries can be utilized in mathematical models and leads a better understanding of vascular mechanical properties and function.

  8. Large Scale 3D Image Reconstruction in Optical Interferometry

    CERN Document Server

    Schutz, Antony; Mary, David; Thiébaut, Eric; Soulez, Ferréol

    2015-01-01

    Astronomical optical interferometers (OI) sample the Fourier transform of the intensity distribution of a source at the observation wavelength. Because of rapid atmospheric perturbations, the phases of the complex Fourier samples (visibilities) cannot be directly exploited , and instead linear relationships between the phases are used (phase closures and differential phases). Consequently, specific image reconstruction methods have been devised in the last few decades. Modern polychromatic OI instruments are now paving the way to multiwavelength imaging. This paper presents the derivation of a spatio-spectral ("3D") image reconstruction algorithm called PAINTER (Polychromatic opticAl INTErferometric Reconstruction software). The algorithm is able to solve large scale problems. It relies on an iterative process, which alternates estimation of polychromatic images and of complex visibilities. The complex visibilities are not only estimated from squared moduli and closure phases, but also from differential phase...

  9. 3D temperature field reconstruction using ultrasound sensing system

    Science.gov (United States)

    Liu, Yuqian; Ma, Tong; Cao, Chengyu; Wang, Xingwei

    2016-04-01

    3D temperature field reconstruction is of practical interest to the power, transportation and aviation industries and it also opens up opportunities for real time control or optimization of high temperature fluid or combustion process. In our paper, a new distributed optical fiber sensing system consisting of a series of elements will be used to generate and receive acoustic signals. This system is the first active temperature field sensing system that features the advantages of the optical fiber sensors (distributed sensing capability) and the acoustic sensors (non-contact measurement). Signals along multiple paths will be measured simultaneously enabled by a code division multiple access (CDMA) technique. Then a proposed Gaussian Radial Basis Functions (GRBF)-based approach can approximate the temperature field as a finite summation of space-dependent basis functions and time-dependent coefficients. The travel time of the acoustic signals depends on the temperature of the media. On this basis, the Gaussian functions are integrated along a number of paths which are determined by the number and distribution of sensors. The inversion problem to estimate the unknown parameters of the Gaussian functions can be solved with the measured times-of-flight (ToF) of acoustic waves and the length of propagation paths using the recursive least square method (RLS). The simulation results show an approximation error less than 2% in 2D and 5% in 3D respectively. It demonstrates the availability and efficiency of our proposed 3D temperature field reconstruction mechanism.

  10. Towards automated electron holographic tomography for 3D mapping of electrostatic potentials

    International Nuclear Information System (INIS)

    Electron-holographic tomography (EHT), that is, the combination of off-axis electron holography with electron tomography, was successfully applied for the quantitative 3D mapping of electrostatic potentials at the nanoscale. Here we present the first software package (THOMAS) for semi-automated acquisition of holographic tilt series, a prerequisite for efficient data collection. Using THOMAS, the acquisition time for a holographic tilt series, consisting of object and reference holograms, is reduced by a factor of five on average, compared to the previous, completely manual approaches. Moreover, the existing software packages for retrieving amplitude and phase information from electron holograms have been extended, now including a one-step procedure for holographic tilt series reconstruction. Furthermore, a modified SIRT algorithm (WSIRT) was implemented for the quantitative 3D reconstruction of the electrostatic potential from the aligned phase tilt series. Finally, the application of EHT to a polystyrene latex sphere test-specimen and a pn-doped Ge 'needle'-shaped specimen are presented, illustrating the quantitative character of EHT. For both specimens the mean inner potential (MIP) values were accurately determined from the reconstructed 3D potential. For the Ge specimen, additionally the 'built-in' voltage across the pn junction of 0.5 V was obtained.

  11. Role of 3-D CT reconstruction of laryngeal mucosal surface in preoperative staging of laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Sang Hwa; Park, Jong Yeon; Lee, Young Jun; Kim, Kun Il; Kim, Byung Soo; Wang, Soo Guen [Pusan National University, Busan (Korea, Republic of); Sol, Chang Hyo [Hong-In Total Imaing Diagnostic Clinic, Pusan (Korea, Republic of)

    1994-01-15

    CT or MRT is performed in preoperative staging of laryngeal cancer. These methods are used in assessment of the deep tissues and cartilage of the larynx, but cannot compete with laryngoscopy in the evaluation of the laryngeal surface. The purpose of this study is to evaluate feasibility and clinical value of the 3-D reconstruction of the mucosal surface in laryngeal cancer. Twenty two patients with laryngeal cancer proved by means of surgical exploration (pathologic) or clinical examinations including laryngoscope, imaging studies and biopsy underwent preoperative staging with computed tomography(CT) and three dimensional(3D) CT reconstruction. The TNM classification of the American Joint Committee on Cancer was used to compare the imaging findings with pathologic or clinical staging. When the extension of primary tumor(T staging) was evaluated, the findings at only transaxial CT and those at pathologic or clinical examination were concordant in 8 of 14 cases(57.1%) of supraglottic tumor, and 3 of 6 cases(50%) of glottic tumor. The overall accuracy of CT with additional 3D-reconstruction was 85.7% for assessment of supraglottic tumor, and 66.6% for glottic tumor. 3D CT reconstruction after transaxial CT may improve outcome in preoperative staging of laryngeal cancer and has a potential value in guiding management decisions.

  12. 3D particle tracking velocimetry using dynamic discrete tomography for plasma physics applications

    DEFF Research Database (Denmark)

    Moseev, Dmitry; Alpers, Andreas; Gritzmann, Peter;

    2013-01-01

    3D particle tracking velocimetry (PTV) is a diagnostic technique which is widely used for studying flows, combustion, and plasmas. Current tomographic particle tracking methods are based on the multiplicative algebraic reconstruction technique and used for reconstructing the distribution of multi......-pixel sized particles as greylevel images. Reconstructions obtained by these methods do not necessarily match the experimental data. We propose a new algorithm which can be used for tracking dust particles in tokamaks and stellarators, as well as in low-temperature and complex plasmas. The dynamic discrete...... tomography algorithm is efficient for data from two projection directions and exact. The non-uniqueness can be detected and tracked individually. The algorithm performance is proportional to N3 on average where N is the number of particles in the reconstruction. There is a room for further improvement...

  13. 3D reconstruction of concave surfaces using polarisation imaging

    Science.gov (United States)

    Sohaib, A.; Farooq, A. R.; Ahmed, J.; Smith, L. N.; Smith, M. L.

    2015-06-01

    This paper presents a novel algorithm for improved shape recovery using polarisation-based photometric stereo. The majority of previous research using photometric stereo involves 3D reconstruction using both the diffuse and specular components of light; however, this paper suggests the use of the specular component only as it is the only form of light that comes directly off the surface without subsurface scattering or interreflections. Experiments were carried out on both real and synthetic surfaces. Real images were obtained using a polarisation-based photometric stereo device while synthetic images were generated using PovRay® software. The results clearly demonstrate that the proposed method can extract three-dimensional (3D) surface information effectively even for concave surfaces with complex texture and surface reflectance.

  14. 3D reconstruction of porous electrodes and microstructure modelling

    Energy Technology Data Exchange (ETDEWEB)

    Joos, Jochen; Rueger, Bernd; Weber, Andre; Ivers-Tiffee, Ellen [Karlsruher Institute fuer Technologie (KIT), Karlsruhe (DE). Inst. fuer Werkstoffe der Elektrotechnik (IWE); Carraro, Thomas [Heidelberg Univ. (Germany). Inst. fuer Angewandte Mathematik

    2010-07-01

    The performance of a solid oxide fuel cell (SOFC) is limited by electrode polarisation processes, depending both on material composition and microstructure characteristics. To understand and improve electrode performance, a detailed knowledge of the electrode microstructure is essential. Recent developments in 3D image reconstruction combined with Focused Ion Beam (FIB) and Scanning Electron Microscopy (SEM) techniques proved a way to achieve highly detailed microstructural data. From this data the determination of valuable microstructural parameters is possible. The microstructure is commonly described by parameters as volume/porosity fraction, tortuosity of pores/materal (or: tortuosity of electronic and ionic transport in 2-phase materials), three-phase boundary length (electronic conducting electrodes) or electrode surface area (mixed conducting electrodes). Based on these parameters and with the help of adequate models, the electrode performance can be estimated. It is obvious that the accurateness of the model prediction depends on the quality of the parameters. Different groups reported first trials in the reconstruction of SOFC electrodes by FIB/SEM methods. They all used the reconstruction to calculate microstructural parameters. But nevertheless a lot of questions remain, primarily questions concerning the accuracy of the reconstruction or the minimum size of the volume that has to be reconstructed to obtain meaningful results. In this contribution, a ZEISS 1540XB CrossBeam {sup registered} was used to provide over 700 consecutive images of a porous LSCF (La{sub 0.58}Sr{sub 0.4}CO{sub 0.2.}Fe{sub 0.8}O{sub 3-{delta}})-cathode. The calculation of the key microstructural parameters (i) volume/porosity fraction (ii) electrode surface area and (iii) tortuosity of pores and material from 3D FIB/SEM-data will be presented. Additionally the influence of the reconstruction-volume on the calculated parameters will be discussed. Also the presented technique is

  15. 3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Iturrondobeitia, M., E-mail: maider.iturrondobeitia@ehu.es; Okariz, A.; Fernandez-Martinez, R.; Jimbert, P.; Guraya, T.; Ibarretxe, J. [eMERG, University of the Basque Country, Rafael Moreno Pitxitxi street 2 and 3, 48013, Bilbao (Spain)

    2015-03-30

    The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V{sub clay} (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite.

  16. Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner

    International Nuclear Information System (INIS)

    We present a pragmatic approach to image reconstruction for data from the micro crystal elements system (MiCES) fully 3D mouse imaging positron emission tomography (PET) scanner under construction at the University of Washington. Our approach is modelled on fully 3D image reconstruction used in clinical PET scanners, which is based on Fourier rebinning (FORE) followed by 2D iterative image reconstruction using ordered-subsets expectation-maximization (OSEM). The use of iterative methods allows modelling of physical effects (e.g., statistical noise, detector blurring, attenuation, etc), while FORE accelerates the reconstruction process by reducing the fully 3D data to a stacked set of independent 2D sinograms. Previous investigations have indicated that non-stationary detector point-spread response effects, which are typically ignored for clinical imaging, significantly impact image quality for the MiCES scanner geometry. To model the effect of non-stationary detector blurring (DB) in the FORE+OSEM(DB) algorithm, we have added a factorized system matrix to the ASPIRE reconstruction library. Initial results indicate that the proposed approach produces an improvement in resolution without an undue increase in noise and without a significant increase in the computational burden. The impact on task performance, however, remains to be evaluated

  17. Facial-paralysis diagnostic system based on 3D reconstruction

    Science.gov (United States)

    Khairunnisaa, Aida; Basah, Shafriza Nisha; Yazid, Haniza; Basri, Hassrizal Hassan; Yaacob, Sazali; Chin, Lim Chee

    2015-05-01

    The diagnostic process of facial paralysis requires qualitative assessment for the classification and treatment planning. This result is inconsistent assessment that potential affect treatment planning. We developed a facial-paralysis diagnostic system based on 3D reconstruction of RGB and depth data using a standard structured-light camera - Kinect 360 - and implementation of Active Appearance Models (AAM). We also proposed a quantitative assessment for facial paralysis based on triangular model. In this paper, we report on the design and development process, including preliminary experimental results. Our preliminary experimental results demonstrate the feasibility of our quantitative assessment system to diagnose facial paralysis.

  18. 4D image reconstruction for emission tomography

    International Nuclear Information System (INIS)

    An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear parameter estimation for a set of spatiotemporal functions chosen to approximately represent the radiotracer distribution, the areas of so-called ‘fully 4D’ image reconstruction and ‘direct kinetic parameter estimation’ are unified within a common framework. Many choices of linear and non-linear parameterization of these functions are considered (including the important case where the parameters have direct biological meaning), along with a review of the algorithms which are able to estimate these often non-linear parameters from emission tomography data. The other crucial components to image reconstruction (the objective function, the system model and the raw data format) are also covered, but in less detail due to the relatively straightforward extension from their corresponding components in conventional 3D image reconstruction. The key unifying concept is that maximum likelihood or maximum a posteriori (MAP) estimation of either linear or non-linear model parameters can be achieved in image space after carrying out a conventional expectation maximization (EM) update of the dynamic image series, using a Kullback-Leibler distance metric (comparing the modeled image values with the EM image values), to optimize the desired parameters. For MAP, an image-space penalty for regularization purposes is required. The benefits of 4D and direct reconstruction reported in the literature are reviewed, and furthermore demonstrated with simple simulation examples. It is clear that the future of reconstructing dynamic or functional emission tomography images, which often exhibit high levels of spatially correlated noise, should ideally exploit these 4D

  19. Computerized 3-D reconstruction of two "double teeth".

    Science.gov (United States)

    Lyroudia, K; Mikrogeorgis, G; Nikopoulos, N; Samakovitis, G; Molyvdas, I; Pitas, I

    1997-10-01

    "Double teeth" is a root malformation in the dentition and the purpose of this study was to reconstruct three-dimensionally the external and internal morphology of two "double teeth". The first set of "double teeth" was formed by the conjunction of a mandibular molar and a premolar, and the second by a conjunction of a maxillary molar and a supernumerary tooth. The process of 3-D reconstruction included serial cross-sectioning, photographs of the sections, digitization of the photographs, extraction of the boundaries of interest for each section, surface representation using triangulation and, finally, surface rendering using photorealistic effects. The resulting three-dimensional representations of the two teeth helped us visualize their external and internal anatomy. The results showed: a) in the first case, fusion of the radical and coronal dentin, as well as fusion of the pulp chambers; and b) in the second case, fusion only of the radical dentin and the pulp chambers. PMID:9550051

  20. 3-D waveform tomography sensitivity kernels for anisotropic media

    KAUST Repository

    Djebbi, R.

    2014-01-01

    The complications in anisotropic multi-parameter inversion lie in the trade-off between the different anisotropy parameters. We compute the tomographic waveform sensitivity kernels for a VTI acoustic medium perturbation as a tool to investigate this ambiguity between the different parameters. We use dynamic ray tracing to efficiently handle the expensive computational cost for 3-D anisotropic models. Ray tracing provides also the ray direction information necessary for conditioning the sensitivity kernels to handle anisotropy. The NMO velocity and η parameter kernels showed a maximum sensitivity for diving waves which results in a relevant choice of those parameters in wave equation tomography. The δ parameter kernel showed zero sensitivity; therefore it can serve as a secondary parameter to fit the amplitude in the acoustic anisotropic inversion. Considering the limited penetration depth of diving waves, migration velocity analysis based kernels are introduced to fix the depth ambiguity with reflections and compute sensitivity maps in the deeper parts of the model.

  1. Block matching 3D random noise filtering for absorption optical projection tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fumene Feruglio, P; Vinegoni, C; Weissleder, R [Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, 185 Cambridge Street, Boston, MA 02114 (United States); Gros, J [Department of Genetics, Harvard Medical School, 77 Avenue Louis Pasteur, Boston MA 02115 (United States); Sbarbati, A, E-mail: cvinegoni@mgh.harvard.ed [Department of Morphological and Biomedical Sciences, University of Verona, Strada Le Grazie 8, 37134 Verona (Italy)

    2010-09-21

    Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies. The techniques' principles are similar to the ones used for x-ray computed tomography and are based on the approximation of negligible light scattering in optically cleared samples. The optical clearing is achieved by a chemical procedure which aims at substituting the cellular fluids within the sample with a cell membranes' index matching solution. Once cleared the sample presents very low scattering and is then illuminated with a light collimated beam whose intensity is captured in transillumination mode by a CCD camera. Different projection images of the sample are subsequently obtained over a 360{sup 0} full rotation, and a standard backprojection algorithm can be used in a similar fashion as for x-ray tomography in order to obtain absorption maps. Because not all biological samples present significant absorption contrast, it is not always possible to obtain projections with a good signal-to-noise ratio, a condition necessary to achieve high-quality tomographic reconstructions. Such is the case for example, for early stage's embryos. In this work we demonstrate how, through the use of a random noise removal algorithm, the image quality of the reconstructions can be considerably improved even when the noise is strongly present in the acquired projections. Specifically, we implemented a block matching 3D (BM3D) filter applying it separately on each acquired transillumination projection before performing a complete three-dimensional tomographical reconstruction. To test the efficiency of the adopted filtering scheme, a phantom and a real biological sample were processed. In both cases, the BM3D filter led to a signal-to-noise ratio

  2. 3D Coronal Density Reconstruction and Retrieving the Magnetic Field Structure during Solar Minimum

    CERN Document Server

    Kramar, M; Mikić, Z; Davila, J

    2014-01-01

    Measurement of the coronal magnetic field is a crucial ingredient in understanding the nature of solar coronal phenomena at all scales. We employed STEREO/COR1 data obtained during a deep minimum of solar activity in February 2008 (Carrington rotation CR 2066) to retrieve and analyze the three-dimensional (3D) coronal electron density in the range of heights from 1.5 to 4 Rsun using a tomography method. With this, we qualitatively deduced structures of the coronal magnetic field. The 3D electron density analysis is complemented by the 3D STEREO/EUVI emissivity in the 195 A band obtained by tomography for the same CR. A global 3D MHD model of the solar corona was used to relate the reconstructed 3D density and emissivity to open/closed magnetic field structures. We show that the density maximum locations can serve as an indicator of current sheet position, while the locations of the density gradient maximum can be a reliable indicator of coronal hole boundaries. We find that the magnetic field configuration du...

  3. Optimized 3D Street Scene Reconstruction from Driving Recorder Images

    Directory of Open Access Journals (Sweden)

    Yongjun Zhang

    2015-07-01

    Full Text Available The paper presents an automatic region detection based method to reconstruct street scenes from driving recorder images. The driving recorder in this paper is a dashboard camera that collects images while the motor vehicle is moving. An enormous number of moving vehicles are included in the collected data because the typical recorders are often mounted in the front of moving vehicles and face the forward direction, which can make matching points on vehicles and guardrails unreliable. Believing that utilizing these image data can reduce street scene reconstruction and updating costs because of their low price, wide use, and extensive shooting coverage, we therefore proposed a new method, which is called the Mask automatic detecting method, to improve the structure results from the motion reconstruction. Note that we define vehicle and guardrail regions as “mask” in this paper since the features on them should be masked out to avoid poor matches. After removing the feature points in our new method, the camera poses and sparse 3D points that are reconstructed with the remaining matches. Our contrast experiments with the typical pipeline of structure from motion (SfM reconstruction methods, such as Photosynth and VisualSFM, demonstrated that the Mask decreased the root-mean-square error (RMSE of the pairwise matching results, which led to more accurate recovering results from the camera-relative poses. Removing features from the Mask also increased the accuracy of point clouds by nearly 30%–40% and corrected the problems of the typical methods on repeatedly reconstructing several buildings when there was only one target building.

  4. Infiltration front monitoring using 3D Electrical Resistivity Tomography

    Science.gov (United States)

    Oxarango, Laurent; Audebert, Marine; Guyard, Helene; Clement, Remi

    2016-04-01

    The electrical resistivity tomography (ERT) geophysical method is commonly used to identify the spatial distribution of electrical resisitivity in the soil at the field scale. Recent progress in commercial acquisition systems allows repeating fast acquisitions (10 min) in order to monitor a 3D dynamic phenomenon. Since the ERT method is sensitive to moisture content variations, it can thus be used to delineate the infiltration shape during water infiltration. In heterogeneous conditions, the 3D infiltration shape is a crucial information because it could differ significantly from the homogeneous behavior. In a first step, the ERT method is validated at small scale ( 10m). Two examples of leachate injection monitoring in municipal solid waste landfills are used to put forward benefits and limitations of the ERT-MICS method. Effective infiltration porosities in a range between 3% and 8% support the assumption of a flow in heterogeneous media. Audebert, M., R. Clément, N. Touze-Foltz, T. Günther, S. Moreau, and C. Duquennoi (2014), Time-lapse ERT interpretation methodology for leachate injection monitoring based on multiple inversions and a clustering strategy (MICS), Journal of Applied Geophysics, 111, 320-333. Keywords: ERT, infiltration front, field survey

  5. Fast vision-based catheter 3D reconstruction

    Science.gov (United States)

    Moradi Dalvand, Mohsen; Nahavandi, Saeid; Howe, Robert D.

    2016-07-01

    Continuum robots offer better maneuverability and inherent compliance and are well-suited for surgical applications as catheters, where gentle interaction with the environment is desired. However, sensing their shape and tip position is a challenge as traditional sensors can not be employed in the way they are in rigid robotic manipulators. In this paper, a high speed vision-based shape sensing algorithm for real-time 3D reconstruction of continuum robots based on the views of two arbitrary positioned cameras is presented. The algorithm is based on the closed-form analytical solution of the reconstruction of quadratic curves in 3D space from two arbitrary perspective projections. High-speed image processing algorithms are developed for the segmentation and feature extraction from the images. The proposed algorithms are experimentally validated for accuracy by measuring the tip position, length and bending and orientation angles for known circular and elliptical catheter shaped tubes. Sensitivity analysis is also carried out to evaluate the robustness of the algorithm. Experimental results demonstrate good accuracy (maximum errors of  ±0.6 mm and  ±0.5 deg), performance (200 Hz), and robustness (maximum absolute error of 1.74 mm, 3.64 deg for the added noises) of the proposed high speed algorithms.

  6. 3D Reconstruction of virtual colon structures from colonoscopy images.

    Science.gov (United States)

    Hong, DongHo; Tavanapong, Wallapak; Wong, Johnny; Oh, JungHwan; de Groen, Piet C

    2014-01-01

    This paper presents the first fully automated reconstruction technique of 3D virtual colon segments from individual colonoscopy images. It is the basis of new software applications that may offer great benefits for improving quality of care for colonoscopy patients. For example, a 3D map of the areas inspected and uninspected during colonoscopy can be shown on request of the endoscopist during the procedure. The endoscopist may revisit the suggested uninspected areas to reduce the chance of missing polyps that reside in these areas. The percentage of the colon surface seen by the endoscopist can be used as a coarse objective indicator of the quality of the procedure. The derived virtual colon models can be stored for post-procedure training of new endoscopists to teach navigation techniques that result in a higher level of procedure quality. Our technique does not require a prior CT scan of the colon or any global positioning device. Our experiments on endoscopy images of an Olympus synthetic colon model reveal encouraging results with small average reconstruction errors (4.1 mm for the fold depths and 12.1 mm for the fold circumferences). PMID:24225230

  7. Digital 3D facial reconstruction of George Washington

    Science.gov (United States)

    Razdan, Anshuman; Schwartz, Jeff; Tocheri, Mathew; Hansford, Dianne

    2006-02-01

    PRISM is a focal point of interdisciplinary research in geometric modeling, computer graphics and visualization at Arizona State University. Many projects in the last ten years have involved laser scanning, geometric modeling and feature extraction from such data as archaeological vessels, bones, human faces, etc. This paper gives a brief overview of a recently completed project on the 3D reconstruction of George Washington (GW). The project brought together forensic anthropologists, digital artists and computer scientists in the 3D digital reconstruction of GW at 57, 45 and 19 including detailed heads and bodies. Although many other scanning projects such as the Michelangelo project have successfully captured fine details via laser scanning, our project took it a step further, i.e. to predict what that individual (in the sculpture) might have looked like both in later and earlier years, specifically the process to account for reverse aging. Our base data was GWs face mask at Morgan Library and Hudons bust of GW at Mount Vernon, both done when GW was 53. Additionally, we scanned the statue at the Capitol in Richmond, VA; various dentures, and other items. Other measurements came from clothing and even portraits of GW. The digital GWs were then milled in high density foam for a studio to complete the work. These will be unveiled at the opening of the new education center at Mt Vernon in fall 2006.

  8. Dynamic 3D computed tomography scanner for vascular imaging

    Science.gov (United States)

    Lee, Mark K.; Holdsworth, David W.; Fenster, Aaron

    2000-04-01

    A 3D dynamic computed-tomography (CT) scanner was developed for imaging objects undergoing periodic motion. The scanner system has high spatial and sufficient temporal resolution to produce quantitative tomographic/volume images of objects such as excised arterial samples perfused under physiological pressure conditions and enables the measurements of the local dynamic elastic modulus (Edyn) of the arteries in the axial and longitudinal directions. The system was comprised of a high resolution modified x-ray image intensifier (XRII) based computed tomographic system and a computer-controlled cardiac flow simulator. A standard NTSC CCD camera with a macro lens was coupled to the electro-optically zoomed XRII to acquire dynamic volumetric images. Through prospective cardiac gating and computer synchronized control, a time-resolved sequence of 20 mm thick high resolution volume images of porcine aortic specimens during one simulated cardiac cycle were obtained. Performance evaluation of the scanners illustrated that tomographic images can be obtained with resolution as high as 3.2 mm-1 with only a 9% decrease in the resolution for objects moving at velocities of 1 cm/s in 2D mode and static spatial resolution of 3.55 mm-1 with only a 14% decrease in the resolution in 3D mode for objects moving at a velocity of 10 cm/s. Application of the system for imaging of intact excised arterial specimens under simulated physiological flow/pressure conditions enabled measurements of the Edyn of the arteries with a precision of +/- kPa for the 3D scanner. Evaluation of the Edyn in the axial and longitudinal direction produced values of 428 +/- 35 kPa and 728 +/- 71 kPa, demonstrating the isotropic and homogeneous viscoelastic nature of the vascular specimens. These values obtained from the Dynamic CT systems were not statistically different (p less than 0.05) from the values obtained by standard uniaxial tensile testing and volumetric measurements.

  9. 3D Reconstruction of Irregular Buildings and Buddha Statues

    Science.gov (United States)

    Zhang, K.; Li, M.-j.

    2014-04-01

    Three-dimensional laser scanning could acquire object's surface data quickly and accurately. However, the post-processing of point cloud is not perfect and could be improved. Based on the study of 3D laser scanning technology, this paper describes the details of solutions to modelling irregular ancient buildings and Buddha statues in Jinshan Temple, which aiming at data acquisition, modelling and texture mapping, etc. In order to modelling irregular ancient buildings effectively, the structure of each building is extracted manually by point cloud and the textures are mapped by the software of 3ds Max. The methods clearly combine 3D laser scanning technology with traditional modelling methods, and greatly improves the efficiency and accuracy of the ancient buildings restored. On the other hand, the main idea of modelling statues is regarded as modelling objects in reverse engineering. The digital model of statues obtained is not just vivid, but also accurate in the field of surveying and mapping. On this basis, a 3D scene of Jinshan Temple is reconstructed, which proves the validity of the solutions.

  10. Compton scatter and randoms corrections for origin ensembles 3D PET reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, Arkadiusz [Harvard Medical School, Boston, MA (United States). Dept. of Radiology; Brigham and Women' s Hospital, Boston, MA (United States); Kadrmas, Dan J. [Utah Univ., Salt Lake City, UT (United States). Utah Center for Advanced Imaging Research (UCAIR)

    2011-07-01

    In this work we develop a novel approach to correction for scatter and randoms in reconstruction of data acquired by 3D positron emission tomography (PET) applicable to tomographic reconstruction done by the origin ensemble (OE) approach. The statistical image reconstruction using OE is based on calculation of expectations of the numbers of emitted events per voxel based on complete-data space. Since the OE estimation is fundamentally different than regular statistical estimators such those based on the maximum likelihoods, the standard methods of implementation of scatter and randoms corrections cannot be used. Based on prompts, scatter, and random rates, each detected event is graded in terms of a probability of being a true event. These grades are utilized by the Markov Chain Monte Carlo (MCMC) algorithm used in OE approach for calculation of the expectation over the complete-data space of the number of emitted events per voxel (OE estimator). We show that the results obtained with the OE are almost identical to results obtained by the maximum likelihood-expectation maximization (ML-EM) algorithm for reconstruction for experimental phantom data acquired using Siemens Biograph mCT 3D PET/CT scanner. The developed correction removes artifacts due to scatter and randoms in investigated 3D PET datasets. (orig.)

  11. Human cardiac telocytes: 3D imaging by FIB-SEM tomography.

    Science.gov (United States)

    Cretoiu, D; Hummel, E; Zimmermann, H; Gherghiceanu, M; Popescu, L M

    2014-11-01

    Telocyte (TC) is a newly identified type of cell in the cardiac interstitium (www.telocytes.com). TCs are described by classical transmission electron microscopy as cells with very thin and long telopodes (Tps; cellular prolongations) having podoms (dilations) and podomers (very thin segments). TCs' three-dimensional (3D) morphology is still unknown. Cardiac TCs seem to be particularly involved in long and short distance intercellular signalling and, therefore, their 3D architecture is important for understanding their spatial connections. Using focused ion beam scanning electron microscopy (FIB-SEM) we show, for the first time, the whole ultrastructural anatomy of cardiac TCs. 3D reconstruction of cardiac TCs by FIB-SEM tomography confirms that they have long, narrow but flattened (ribbon-like) telopodes, with humps generated by the podoms. FIB-SEM tomography also confirms the network made by TCs in the cardiac interstitium through adherens junctions. This study provides the first FIB-SEM tomography of a human cell type.

  12. Inclusion of high resolution MODIS maps on a 3D tropospheric water vapor GPS tomography model

    Science.gov (United States)

    Benevides, Pedro; Catalao, Joao; Nico, Giovanni; Miranda, Pedro M. A.

    2015-10-01

    Observing the water vapor distribution on the troposphere remains a challenge for the weather forecast. Radiosondes provide precise water vapor profiles of the troposphere, but lack geographical and temporal coverage, while satellite meteorological maps have good spatial resolution but even poorer temporal resolution. GPS has proved its capacity to measure the integrated water vapor in all weather conditions with high temporal sampling frequency. However these measurements lack a vertical water vapor discretization. Reconstruction of the slant path GPS observation to the satellite allows oblique water vapor measurements. Implementation of a 3D grid of voxels along the troposphere over an area where GPS stations are available enables the observation ray tracing. A relation between the water vapor density and the distanced traveled inside the voxels is established, defining GPS tomography. An inverse problem formulation is needed to obtain a water vapor solution. The combination of precipitable water vapor (PWV) maps obtained from MODIS satellite data with the GPS tomography is performed in this work. The MODIS PWV maps can have 1 or 5 km pixel resolution, being obtained 2 times per day in the same location at most. The inclusion of MODIS PWV maps provides an enhanced horizontal resolution for the tomographic solution and benefits the stability of the inversion problem. A 3D tomographic grid was adjusted over a regional area covering Lisbon, Portugal, where a GNSS network of 9 receivers is available. Radiosonde measurements in the area are used to evaluate the 3D water vapor tomography maps.

  13. The interactive presentation of 3D information obtained from reconstructed datasets and 3D placement of single histological sections with the 3D portable document format

    OpenAIRE

    de Boer, B. A.; Soufan, A. T.; Hagoort, J.; Mohun, T. J.; van den Hoff, M. J. B.; Hasman, A.; Voorbraak, F. P. J. M.; Moorman, A. F. M.; Ruijter, J.M.

    2011-01-01

    Interpretation of the results of anatomical and embryological studies relies heavily on proper visualization of complex morphogenetic processes and patterns of gene expression in a three-dimensional (3D) context. However, reconstruction of complete 3D datasets is time consuming and often researchers study only a few sections. To help in understanding the resulting 2D data we developed a program (TRACTS) that places such arbitrary histological sections into a high-resolution 3D model of the de...

  14. The interactive presentation of 3D information obtained from reconstructed datasets and 3D placement of single histological sections with the 3D portable document format

    NARCIS (Netherlands)

    B.A. de Boer; A.T. Soufan; J. Hagoort; T.J. Mohun; M.J.B. van den Hoff; A. Hasman; F.P.J.M. Voorbraak; A.F.M. Moorman; J.M. Ruijter

    2011-01-01

    Interpretation of the results of anatomical and embryological studies relies heavily on proper visualization of complex morphogenetic processes and patterns of gene expression in a three-dimensional (3D) context. However, reconstruction of complete 3D datasets is time consuming and often researchers

  15. Electrochemical fields within 3D reconstructed microstructures of mixed ionic and electronic conducting devices

    Science.gov (United States)

    Zhang, Yanxiang; Chen, Yu; Lin, Ye; Yan, Mufu; Harris, William M.; Chiu, Wilson K. S.; Ni, Meng; Chen, Fanglin

    2016-11-01

    The performance and stability of the mixed ionic and electronic conducting (MIEC) membrane devices, such as solid oxide cells (SOCs) and oxygen separation membranes (OSMs) interplay tightly with the transport properties and the three-dimensional (3D) microstructure of the membrane. However, development of the MIEC devices is hindered by the limited knowledge about the distribution of electrochemical fields within the 3D local microstructures, especially at surface and interface. In this work, a generic model conforming to local thermodynamic equilibrium is developed to calculate the electrochemical fields, such as electric potential and oxygen chemical potential, within the 3D microstructure of the MIEC membrane. Stability of the MIEC membrane is evaluated by the distribution of oxygen partial pressure. The cell-level performance such as polarization resistance and voltage vs. current curve can be further calculated. Case studies are performed to demonstrate the capability of the framework by using X-ray computed tomography reconstructed 3D microstructures of a SOC and an OSM. The calculation method demonstrates high computational efficiency for large size 3D tomographic microstructures, and permits parallel calculation. The framework can serve as a powerful tool for correlating the transport properties and the 3D microstructure to the performance and the stability of MIEC devices.

  16. New X-Ray Tomography Method Based on the 3D Radon Transform Compatible with Anisotropic Sources

    Science.gov (United States)

    Vassholz, M.; Koberstein-Schwarz, B.; Ruhlandt, A.; Krenkel, M.; Salditt, T.

    2016-02-01

    In this work, we propose a novel computed tomography (CT) approach for three-dimensional (3D) object reconstruction, based on a generalized tomographic geometry with two-dimensional angular sampling (two angular degrees of freedom). The reconstruction is based on the 3D radon transform and is compatible with anisotropic beam conditions. This allows isotropic 3D imaging with a source, which can be extended along one direction for increased flux, while high resolution is achieved by a small source size only in the orthogonal direction. This novel scheme for analytical CT is demonstrated by numerical simulations and proof-of-concept experiments. In this way high resolution and coherence along a single direction determines the reconstruction quality of the entire 3D data set, opening up, for example, new opportunities to achieve nanoscale resolution and/or phase contrast with low brilliance sources such as laboratory x-ray or neutron sources.

  17. A fast rebinning algorithm for 3D positron emission tomography using John's equation

    Science.gov (United States)

    Defrise, Michel; Liu, Xuan

    1999-08-01

    Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.

  18. Applicability of 3D-CT facial reconstruction for forensic individual identification Aplicabilidade da reconstrução facial em 3D-TC para identificação individual forense

    OpenAIRE

    Sara dos Santos Rocha; Dalton Luiz de Paula Ramos; Marcelo Gusmão Paraíso Cavalcanti

    2003-01-01

    Computed tomography (CT) is used in several clinical dentistry applications even by axial slices and two and three-dimensional reconstructed images (2D-CT and 3D-CT). The purpose of the current study is to assess the precision of linear measurements made in 3D-CT using craniometric patterns for individual identification in Forensic Dentistry. Five cadaver heads were submitted to a spiral computed tomography using axial slices, and 3D-CT reconstructions were obtained by volume rendering techni...

  19. Robust 3D reconstruction with an RGB-D camera.

    Science.gov (United States)

    Wang, Kangkan; Zhang, Guofeng; Bao, Hujun

    2014-11-01

    We present a novel 3D reconstruction approach using a low-cost RGB-D camera such as Microsoft Kinect. Compared with previous methods, our scanning system can work well in challenging cases where there are large repeated textures and significant depth missing problems. For robust registration, we propose to utilize both visual and geometry features and combine SFM technique to enhance the robustness of feature matching and camera pose estimation. In addition, a novel prior-based multicandidates RANSAC is introduced to efficiently estimate the model parameters and significantly speed up the camera pose estimation under multiple correspondence candidates. Even when serious depth missing occurs, our method still can successfully register all frames together. Loop closure also can be robustly detected and handled to eliminate the drift problem. The missing geometry can be completed by combining multiview stereo and mesh deformation techniques. A variety of challenging examples demonstrate the effectiveness of the proposed approach.

  20. Electrical impedance tomography in 3D using two electrode planes: characterization and evaluation.

    Science.gov (United States)

    Wagenaar, Justin; Adler, Andy

    2016-06-01

    Electrical impedance tomography (EIT) uses body surface electrical stimulation and measurements to create conductivity images; it shows promise as a non-invasive technology to monitor the distribution of lung ventilation. Most applications of EIT have placed electrodes in a 2D ring around the thorax, and thus produced 2D cross-sectional images. These images are unable to distinguish out-of-plane contributions, or to image volumetric effects. Volumetric EIT can be calculated using multiple electrode planes and a 3D reconstruction algorithm. However, while 3D reconstruction algorithms are available, little has been done to understand the performance of 3D EIT in terms of the measurement configurations available. The goal of this paper is to characterize the phantom and in vivo performance of 3D EIT with two electrode planes. First, phantom measurements are used to measure the reconstruction characteristics of seven stimulation and measurement configurations. Measurements were then performed on eight healthy volunteers as a function of body posture, postures, and with various electrode configurations. Phantom results indicate that 3D EIT using two rings of electrodes provides reasonable resolution in the electrode plane but low vertical resolution. For volunteers, functional EIT images are created from inhalation curve features to analyze the effect of posture (standing, sitting, supine and decline) on regional lung behaviour. An ability to detect vertical changes in lung volume distribution was shown for two electrode configurations. Based on tank and volunteer results, we recommend the use of the 'square' stimulation and measurement pattern for two electrode plane EIT.

  1. Neurofunctional systems. 3D reconstructions with correlated neuroimaging

    International Nuclear Information System (INIS)

    This book introduces, for the first time, computer-generated images of the neurofunctional systems of the human brain. These images are more accurate than drawings. The main views presented are of the medial lemniscus system, auditory system, visual system, basal ganglia, corticospinal system, and the limbic system. The arteries and sulci of the cerebral hemispheres are also illustrated by computer. These images provide a three-dimensional orientation of the intracranial space and help, for example, to assess vascular functional disturbance of the brain. Clinicians will find these images valuable for the spatial interpretation of magnetic resonance (MR), computed tomography (CT), and positron emission tomography (PET) images since many neurofunctional systems cannot be visualized as isolated structures in neuroimaging. Computer-assisted surface reconstructions of the neurofunctional systems and the cerebral arteries serve as a basis for constructing these computer-generated images. The surface reconstructions are anatomically realistic having been created from brain sections with minimal deformations. The method of computer graphics, known as ray tracing, produces digital images form these reconstructions. The computer-generated methods are explained. The computer-generated images are accompanied by illustrations and texts on neuroanatomy and clinical practice. The neurofunctional systems of the human brain are also shown in sections so that the reader can mentally reconstruct the neurofunctional systems, thus facilitating the transformation of information into textbooks and atlantes of MR and CT imaging. The aim of this book is acquaint the reader with the three-dimensional aspects of the neurofunctional systems and the cerebral arteries of the human brain using methods of computer graphics. Computer scientists and those interested in this technique are provided with basic neuroanatomic and neurofunctional information. Physicians will have a clearer understanding

  2. 3D Cone Beam Volumetric Tomography Dedicated to Maxillofacial Radiology

    Directory of Open Access Journals (Sweden)

    Masoud Varshosaz

    2009-01-01

    Full Text Available   "nThe 3D cone beam volume/computed tomography (CBVT/CBCT has been designed for imaging the hard tissues of the maxillofacial region, although it has been used in some era of medical imaging for many years. CBVT is capable of providing a sub-millimeter resolution with the short scanning time of mostly less than 20 seconds and radiation dosages reportedly up to 15 times lower than those of spiral CT scans. In less than a decade, CBVT has revolutionized oral and maxillofacial radiology and is known as the “Standard of Care”. Although development was initially directed towards multiplanar viewing for dental implant and orthodontic treatment planning, secondary applications in other areas continue to expand such as maxillo-facial trauma, temporomandibular joint disorders, sinuse pathosis and upper airway evaluation. The intent of this presentation is to provide an overview of CBVT technology, advantages and disadvantages compared to the other modalities such as 2D images and medical CT and examples of justified cases in the oral & maxillofacial region.   

  3. Uncertainties in polarimetric 3D reconstructions of coronal mass ejections

    CERN Document Server

    Bemporad, Alessandro

    2015-01-01

    This work is aimed at quantifying the uncertainties in the 3D reconstruction of the location of coronal mass ejections (CMEs) obtained with the polarization ratio technique. The method takes advantage of the different distributions along the line of sight (LOS) of total (tB) and polarized (pB) brightnesses to estimate the average location of the emitting plasma. To this end, we assumed two simple electron density distributions along the LOS (a constant density and Gaussian density profiles) for a plasma blob and synthesized the expected tB and pB for different distances $z$ of the blob from the plane of the sky (POS) and different projected altitudes $\\rho$. Reconstructed locations of the blob along the LOS were thus compared with the real ones, allowing a precise determination of uncertainties in the method. Independently of the analytical density profile, when the blob is centered at a small distance from the POS (i.e. for limb CMEs) the distance from the POS starts to be significantly overestimated. Polari...

  4. 3D virtual reconstruction of the Pleistocene cheetah skull from the Tangshan, Nanjing, China

    Institute of Scientific and Technical Information of China (English)

    DONG Wei; HOU Xinwen; LIU Jinyi; FANG Yingsan; JIN Changzhu; ZHU Qizhi

    2007-01-01

    The development of computer tomography and image processing has made it possible to establish virtual 3D reconstruction and non-invasive dissection of fossil specimens. We used these methods to reconstruct a virtual 3D skull of a Pleistocene cheetah skull from the Tuozi cave, Tangshan, Nanjing, and virtually dissected it for anatomic studies, and measured the volumes of different parts of the endocranium. The endocranium of the cheetah skull has showed that its frontal sinus is beehive-like, the frontal lobe of cerebra is relatively large but the temporal lobe is relatively small, its cerebral sulcus and gyrus are more complicated than those of the domestic cat, similar to those of the domestic dog, but simpler than those of giant panda, pig, cattle and horse. The technology of virtual 3D reconstruction and non-invasive dissection of fossil specimens can extend the morphological study from the exterior to the interior, and it can also help to study fragile specimens and virtually backup rare and precious specimens.

  5. Advanced reconstruction algorithms for electron tomography: From comparison to combination

    Energy Technology Data Exchange (ETDEWEB)

    Goris, B. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Roelandts, T. [Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Batenburg, K.J. [Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Centrum Wiskunde and Informatica, Science Park 123, NL-1098XG Amsterdam (Netherlands); Heidari Mezerji, H. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Bals, S., E-mail: sara.bals@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2013-04-15

    In this work, the simultaneous iterative reconstruction technique (SIRT), the total variation minimization (TVM) reconstruction technique and the discrete algebraic reconstruction technique (DART) for electron tomography are compared and the advantages and disadvantages are discussed. Furthermore, we describe how the result of a three dimensional (3D) reconstruction based on TVM can provide objective information that is needed as the input for a DART reconstruction. This approach results in a tomographic reconstruction of which the segmentation is carried out in an objective manner. - Highlights: ► A comparative study between different reconstruction algorithms for tomography is performed. ► Reconstruction algorithms that uses prior knowledge about the specimen have a superior result. ► One reconstruction algorithm can provide the prior knowledge for a second algorithm.

  6. 3-D Reconstruction of Medical Image Using Wavelet Transform and Snake Model

    Directory of Open Access Journals (Sweden)

    Jinyong Cheng

    2009-12-01

    Full Text Available Medical image segmentation is an important step in 3-D reconstruction, and 3-D reconstruction from medical images is an important application of computer graphics and biomedicine image processing. An improved image segmentation method which is suitable for 3-D reconstruction is presented in this paper. A 3-D reconstruction algorithm is used to reconstruct the 3-D model from medical images. Rough edge is obtained by multi-scale wavelet transform at first. With the rough edge, improved gradient vector flow snake model is used and the object contour in the image is found. In the experiments, we reconstruct 3-D models of kidney, liver and brain putamen. The performances of the experiments indicate that the new algorithm can produce accurate 3-D reconstruction.

  7. Evaluation of the Possibility of Applying Spatial 3D Imaging Using X-Ray Computed Tomography Reconstruction Methods for Quantitative Analysis of Multiphase Materials / Rentgenowska Analiza Ilościowa Materiałów Wielofazowych Z Wykorzystaniem Przestrzennego Obrazowania (3D Przy Użyciu Metod Rekonstrukcji Tomografii Komputerowej

    Directory of Open Access Journals (Sweden)

    Matysik P.

    2015-12-01

    Full Text Available In this paper the possibility of using X-ray computed tomography (CT in quantitative metallographic studies of homogeneous and composite materials is presented. Samples of spheroidal cast iron, Fe-Ti powder mixture compact and epoxy composite reinforced with glass fibers, were subjected to comparative structural tests. Volume fractions of each of the phase structure components were determined by conventional methods with the use of a scanning electron microscopy (SEM and X-ray diffraction (XRD quantitative analysis methods. These results were compared with those obtained by the method of spatial analysis of the reconstructed CT image. Based on the comparative analysis, taking into account the selectivity of data verification methods and the accuracy of the obtained results, the authors conclude that the method of computed tomography is suitable for quantitative analysis of several types of structural materials.

  8. Objective and subjective quality assessment of geometry compression of reconstructed 3D humans in a 3D virtual room

    Science.gov (United States)

    Mekuria, Rufael; Cesar, Pablo; Doumanis, Ioannis; Frisiello, Antonella

    2015-09-01

    Compression of 3D object based video is relevant for 3D Immersive applications. Nevertheless, the perceptual aspects of the degradation introduced by codecs for meshes and point clouds are not well understood. In this paper we evaluate the subjective and objective degradations introduced by such codecs in a state of art 3D immersive virtual room. In the 3D immersive virtual room, users are captured with multiple cameras, and their surfaces are reconstructed as photorealistic colored/textured 3D meshes or point clouds. To test the perceptual effect of compression and transmission, we render degraded versions with different frame rates in different contexts (near/far) in the scene. A quantitative subjective study with 16 users shows that negligible distortion of decoded surfaces compared to the original reconstructions can be achieved in the 3D virtual room. In addition, a qualitative task based analysis in a full prototype field trial shows increased presence, emotion, user and state recognition of the reconstructed 3D Human representation compared to animated computer avatars.

  9. Validation of the Gate simulation platform in single photon emission computed tomography and application to the development of a complete 3-dimensional reconstruction algorithm; Validation de la plate-forme de simulation GATE en tomographie a emission monophotonique et application au developpement d'un algorithme de reconstruction 3D complete

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, D

    2003-10-01

    Monte Carlo simulations are currently considered in nuclear medical imaging as a powerful tool to design and optimize detection systems, and also to assess reconstruction algorithms and correction methods for degrading physical effects. Among the many simulators available, none of them is considered as a standard in nuclear medical imaging: this fact has motivated the development of a new generic Monte Carlo simulation platform (GATE), based on GEANT4 and dedicated to SPECT/PET (single photo emission computed tomography / positron emission tomography) applications. We participated during this thesis to the development of the GATE platform within an international collaboration. GATE was validated in SPECT by modeling two gamma cameras characterized by a different geometry, one dedicated to small animal imaging and the other used in a clinical context (Philips AXIS), and by comparing the results obtained with GATE simulations with experimental data. The simulation results reproduce accurately the measured performances of both gamma cameras. The GATE platform was then used to develop a new 3-dimensional reconstruction method: F3DMC (fully 3-dimension Monte-Carlo) which consists in computing with Monte Carlo simulation the transition matrix used in an iterative reconstruction algorithm (in this case, ML-EM), including within the transition matrix the main physical effects degrading the image formation process. The results obtained with the F3DMC method were compared to the results obtained with three other more conventional methods (FBP, MLEM, MLEMC) for different phantoms. The results of this study show that F3DMC allows to improve the reconstruction efficiency, the spatial resolution and the signal to noise ratio with a satisfactory quantification of the images. These results should be confirmed by performing clinical experiments and open the door to a unified reconstruction method, which could be applied in SPECT but also in PET. (author)

  10. 3D mapping of nanoscale electric potentials in semiconductor structures using electron-holographic tomography

    Science.gov (United States)

    Wolf, Daniel; Lubk, Axel; Prete, Paola; Lovergine, Nico; Lichte, Hannes

    2016-09-01

    Off-axis electron holography (EH) is a powerful method for mapping projected electric potentials, such as built-in potentials in semiconductor devices, in two dimensions (2D) at nanometer resolution. However, not well-defined thickness profiles, surface effects, and composition changes of the sample under investigation complicate the interpretation of the projected potentials. Here, we demonstrate how these problems can be overcome by combining EH with tomographic techniques, that is, electron holographic tomography (EHT), reconstructing electric potentials in 3D. We present EHT reconstructions of an n-type MOSFET including its dopant-related built-in potentials inside the device, as well as of a GaAs/AlGaAs core-multishell nanowire containing a 5 nm thick quantum well tube.

  11. DIACHRONIC 3D RECONSTRUCTION FOR LOST CULTURAL HERITAGE

    Directory of Open Access Journals (Sweden)

    G. Guidi

    2012-09-01

    Full Text Available Cultural Heritage artifacts can often be underestimated for their hidden presence in the landscape. Such problem is particularly large in countries like Italy, where the massive amount of "famous" artifacts tends to neglect other presences unless properly exposed, or when the remains are dramatically damaged leaving very few interpretation clues to the visitor. In such cases a virtual presentation of the Cultural Heritage site can be of great help, specially for explaining the evolution of its status, giving sometimes sense to few spare stones. The definition of these digital representations deal with two crucial aspects: on the one hand the possibility of 3D surveying the relics in order to have an accurate geometrical image of the current status of the artifact; on the other hand the presence of historical sources both in form of written text or images, that once properly matched with the current geometrical data, may help to recreate digitally a set of 3D models representing visually the various historical phases (diachronic model, up to the current one. The core of this article is the definition of an integrated methodology that starts from an high-resolution digital survey of the remains of an ancient building and develops a coherent virtual reconstruction from different historical sources, suggesting a scalable method suitable to be re-used for generating a 4D (geometry + time model of the artifact. This approach has been experimented on the "Basilica di San Giovanni in Conca" in Milan, a very significant example for its complex historic evolution that combines evident historic values with an invisible presence inside the city.

  12. Diachronic 3d Reconstruction for Lost Cultural Heritage

    Science.gov (United States)

    Guidi, G.; Russo, M.

    2011-09-01

    Cultural Heritage artifacts can often be underestimated for their hidden presence in the landscape. Such problem is particularly large in countries like Italy, where the massive amount of "famous" artifacts tends to neglect other presences unless properly exposed, or when the remains are dramatically damaged leaving very few interpretation clues to the visitor. In such cases a virtual presentation of the Cultural Heritage site can be of great help, specially for explaining the evolution of its status, giving sometimes sense to few spare stones. The definition of these digital representations deal with two crucial aspects: on the one hand the possibility of 3D surveying the relics in order to have an accurate geometrical image of the current status of the artifact; on the other hand the presence of historical sources both in form of written text or images, that once properly matched with the current geometrical data, may help to recreate digitally a set of 3D models representing visually the various historical phases (diachronic model), up to the current one. The core of this article is the definition of an integrated methodology that starts from an high-resolution digital survey of the remains of an ancient building and develops a coherent virtual reconstruction from different historical sources, suggesting a scalable method suitable to be re-used for generating a 4D (geometry + time) model of the artifact. This approach has been experimented on the "Basilica di San Giovanni in Conca" in Milan, a very significant example for its complex historic evolution that combines evident historic values with an invisible presence inside the city.

  13. Reconstruction tomography from incomplete projections

    International Nuclear Information System (INIS)

    In some instances, reconstruction radionuclide tomography must be carried out from projections that do not include projection values for all portions of the object to be reconstructed. This may occur, for example, when the field of view of the detector is limited, or when an opaque foreign body is present within the object. The effects of such incomplete projections upon reconstructions of computer-simulated phantoms were studied, using iterative and convolution methods. Several methods for reducing the resulting artifacts and inaccuracies are discussed

  14. FIT3D Toolbox : multiple view geometry and 3D reconstruction for MATLAB

    NARCIS (Netherlands)

    Esteban, I.; Dijk, J.; Groen, F.

    2010-01-01

    FIT3D is a Toolbox built for Matlab that aims at unifying and distributing a set of tools that will allow the researcher to obtain a complete 3D model from a set of calibrated images. In this paper we motivate and present the structure of the toolbox in a tutorial and example based approach. Given i

  15. Contribution of 3-D electrical resistivity tomography for landmines detection

    Directory of Open Access Journals (Sweden)

    M. Metwaly

    2008-12-01

    Full Text Available Landmines are a type of inexpensive weapons widely used in the pre-conflicted areas in many countries worldwide. The two main types are the metallic and non-metallic (mostly plastic landmines. They are most commonly investigated by magnetic, ground penetrating radar (GPR, and metal detector (MD techniques. These geophysical techniques however have significant limitations in resolving the non-metallic landmines and wherever the host materials are conductive. In this work, the 3-D electric resistivity tomography (ERT technique is evaluated as an alternative and/or confirmation detection system for both landmine types, which are buried in different soil conditions and at different depths. This can be achieved using the capacitive resistivity imaging system, which does not need direct contact with the ground surface. Synthetic models for each case have been introduced using metallic and non-metallic bodies buried in wet and dry environments. The inversion results using the L1 norm least-squares optimization method tend to produce robust blocky models of the landmine body. The dipole axial and the dipole equatorial arrays tend to have the most favorable geometry by applying dynamic capacitive electrode and they show significant signal strength for data sets with up to 5% noise. Increasing the burial depth relative to the electrode spacing as well as the noise percentage in the resistivity data is crucial in resolving the landmines at different environments. The landmine with dimension and burial depth of one electrode separation unit is over estimated while the spatial resolutions decrease as the burial depth and noise percentage increase.

  16. A novel 3D template for mandible and maxilla reconstruction: Rapid prototyping using stereolithography

    Directory of Open Access Journals (Sweden)

    Samir Kumta

    2015-01-01

    Full Text Available Introduction: Replication of the exact three-dimensional (3D structure of the maxilla and mandible is now a priority whilst attempting reconstruction of these bones to attain a complete functional and aesthetic rehabilitation. We hereby present the process of rapid prototyping using stereolithography to produce templates for modelling bone grafts and implants for maxilla/mandible reconstructions, its applications in tumour/trauma, and outcomes for primary and secondary reconstruction. Materials and Methods: Stereolithographic template-assisted reconstruction was used on 11 patients for the reconstruction of the mandible/maxilla primarily following tumour excision and secondarily for the realignment of post-traumatic malunited fractures or deformity corrections. Data obtained from the computed tomography (CT scans with 1-mm resolution were converted into a computer-aided design (CAD using the CT Digital Imaging and Communications in Medicine (DICOM data. Once a CAD model was constructed, it was converted into a stereolithographic format and then processed by the rapid prototyping technology to produce the physical anatomical model using a resin. This resin model replicates the native mandible, which can be thus used off table as a guide for modelling the bone grafts. Discussion: This conversion of two-dimensional (2D data from CT scan into 3D models is a very precise guide to shaping the bone grafts. Further, this CAD can reconstruct the defective half of the mandible using the mirror image principle, and the normal anatomical model can be created to aid secondary reconstructions. Conclusion: This novel approach allows a precise translation of the treatment plan directly to the surgical field. It is also an important teaching tool for implant moulding and fixation, and helps in patient counselling.

  17. A LabVIEW based user-friendly nano-CT image alignment and 3D reconstruction platform

    CERN Document Server

    Wang, Shenghao; Wang, Zhili; Gao, Kun; Wu, Zhao; Zhu, Peiping; Wu, Ziyu

    2014-01-01

    X-ray nanometer computed tomography (nano-CT) offers applications and opportunities in many scientific researches and industrial areas. Here we present a user-friendly and fast LabVIEW based package running, after acquisition of the raw projection images, a procedure to obtain the inner structure of the sample under analysis. At first, a reliable image alignment procedure fixes possible misalignments among image series due to mechanical errors, thermal expansion and other external contributions, then a novel fast parallel beam 3D reconstruction performs the tomographic reconstruction. The remarkable improved reconstruction after the image calibration confirms the fundamental role of the image alignment procedure. It minimizes blurring and additional streaking artifacts present in a reconstructed slice that cause loss of information and faked structures in the observed material. The nano-CT image alignment and 3D reconstruction LabVIEW package significantly reducing the data process, makes faster and easier th...

  18. A Method for Interactive 3D Reconstruction of Piecewise Planar Objects from Single Images

    OpenAIRE

    Sturm, Peter; Maybank, Steve

    1999-01-01

    International audience We present an approach for 3D reconstruction of objects from a single image. Obviously, constraints on the 3D structure are needed to perform this task. Our approach is based on user-provided coplanarity, perpendicularity and parallelism constraints. These are used to calibrate the image and perform 3D reconstruction. The method is described in detail and results are provided.

  19. Detectability limitations with 3-D point reconstruction algorithms using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lindgren, Erik, E-mail: erik.lindgren@chalmers.se [Department of Materials and Manufacturing Technology, Chalmers University of Technology, Göteborg, 412 96 (Sweden)

    2015-03-31

    The estimated impact of pores in clusters on component fatigue will be highly conservative when based on 2-D rather than 3-D pore positions. To 3-D position and size defects using digital radiography and 3-D point reconstruction algorithms in general require a lower inspection time and in some cases work better with planar geometries than X-ray computed tomography. However, the increase in prior assumptions about the object and the defects will increase the intrinsic uncertainty in the resulting nondestructive evaluation output. In this paper this uncertainty arising when detecting pore defect clusters with point reconstruction algorithms is quantified using simulations. The simulation model is compared to and mapped to experimental data. The main issue with the uncertainty is the possible masking (detectability zero) of smaller defects around some other slightly larger defect. In addition, the uncertainty is explored in connection to the expected effects on the component fatigue life and for different amount of prior object-defect assumptions made.

  20. 3D reconstruction of digitized histological sections for vasculature quantification in the mouse hind limb

    Science.gov (United States)

    Xu, Yiwen; Pickering, J. Geoffrey; Nong, Zengxuan; Gibson, Eli; Ward, Aaron D.

    2014-03-01

    In contrast to imaging modalities such as magnetic resonance imaging and micro computed tomography, digital histology reveals multiple stained tissue features at high resolution (0.25μm/pixel). However, the two-dimensional (2D) nature of histology challenges three-dimensional (3D) quantification and visualization of the different tissue components, cellular structures, and subcellular elements. This limitation is particularly relevant to the vasculature, which has a complex and variable structure within tissues. The objective of this study was to perform a fully automated 3D reconstruction of histology tissue in the mouse hind limb preserving the accurate systemic orientation of the tissues, stained with hematoxylin and immunostained for smooth muscle α actin. We performed a 3D reconstruction using pairwise rigid registrations of 5μm thick, paraffin-embedded serial sections, digitized at 0.25μm/pixel. Each registration was performed using the iterative closest points algorithm on blood vessel landmarks. Landmarks were vessel centroids, determined according to a signed distance map of each pixel to a decision boundary in hue-saturation-value color space; this decision boundary was determined based on manual annotation of a separate training set. Cell nuclei were then automatically extracted and corresponded to refine the vessel landmark registration. Homologous nucleus landmark pairs appearing on not more than two adjacent slides were chosen to avoid registrations which force curved or non-sectionorthogonal structures to be straight and section-orthogonal. The median accumulated target registration errors ± interquartile ranges for the vessel landmark registration, and the nucleus landmark refinement were 43.4+/-42.8μm and 2.9+/-1.7μm, respectively (p<0.0001). Fully automatic and accurate 3D rigid reconstruction of mouse hind limb histology imaging is feasible based on extracted vasculature and nuclei.

  1. Full 3D Microwave Tomography enhanced GPR surveys: a case study

    Science.gov (United States)

    Catapano, Ilaria; Soldovieri, Francesco; Affinito, Antonio; Hugenschmidt, Johannes

    2014-05-01

    Ground Penetrating Radar (GPR) systems are well assessed non-invasive diagnostic tools capable of providing high resolution images of the inner structure of the probed spatial region. Owing to this capability, GPR systems are nowadays more and more considered in the frame of civil engineering surveys since they may give information on constructive details as well as on the aging and risk factors affecting the healthiness of an infrastructure. In this frame, accurate, reliable and easily interpretable images of the probed scenarios are mandatory in order to support the management of maintenance works and assure the safety of structures. Such a requirement motivates the use of different and sophisticated data processing approaches in order to compare more than one image of the same scene, thus improving the reliability and objectiveness of the GPR survey results. Among GPR data processing procedures, Microwave Tomography approaches based on the Born approximation face the imaging as the solution of a linear inverse problem, which is solved by using the Truncated Singular Value Decomposition as a regularized inversion scheme [1]. So far, an approach exploiting a 2D scalar model of the scattering phenomenon have been adopted to process GPR data gathered along a single scan. In this case, 3D images are obtained by interpolating 2D reconstructions (this is referred commonly as pseudo 3D imaging). Such an imaging approach have provided valuable results in several real cases dealing with not only surveys for civil engineering but also archeological prospection, subservice monitoring, security surveys and so on [1-4]. These encouraging results have motivated the development of a full 3D Microwave Tomography approach capable of accounting for the vectorial nature of the wave propagation. The reconstruction capabilities of this novel approach have been assessed mainly against experimental data collected in laboratory controlled conditions. The obtained results corroborate

  2. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de physique, de génie physique et d’optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Binnekamp, Dirk [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best 5680 DA (Netherlands)

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  3. Acceleration of EM-Based 3D CT Reconstruction Using FPGA.

    Science.gov (United States)

    Choi, Young-Kyu; Cong, Jason

    2016-06-01

    Reducing radiation doses is one of the key concerns in computed tomography (CT) based 3D reconstruction. Although iterative methods such as the expectation maximization (EM) algorithm can be used to address this issue, applying this algorithm to practice is difficult due to the long execution time. Our goal is to decrease this long execution time to an order of a few minutes, so that low-dose 3D reconstruction can be performed even in time-critical events. In this paper we introduce a novel parallel scheme that takes advantage of numerous block RAMs on field-programmable gate arrays (FPGAs). Also, an external memory bandwidth reduction strategy is presented to reuse both the sinogram and the voxel intensity. Moreover, a customized processing engine based on the FPGA is presented to increase overall throughput while reducing the logic consumption. Finally, a hardware and software flow is proposed to quickly construct a design for various CT machines. The complete reconstruction system is implemented on an FPGA-based server-class node. Experiments on actual patient data show that a 26.9 × speedup can be achieved over a 16-thread multicore CPU implementation. PMID:26462240

  4. 3-D reconstruction for mass lesions in the head and neck

    International Nuclear Information System (INIS)

    3-D reconstructions in the head and neck were carried out on 21 normals and 11 patients with space-occupying lesions, both before and after the administration of Gd-DTPA. The 3-D reconstructions were obtained by the 'ray-tracing' method. For the 3-D reconstructions, portions of the skull surface image were removed to permit views of the deeper tissues. The 3-D reconstructions included an hypoglossus neurinoma, a glomus tumour, two carcinomas of the maxillary antra, three naso-pharyngeal carcinomas, a parotid adenoma, an oro-pharyngeal haemangioma and two lesions in the neck. The 3-D reconstructions provided a better understanding of the morphology than was obtained from the two-dimensional images. 3-D reconstructions of lesions in the head and neck will become a valuable diagnostic method for demonstrating space-occupying lesions, particularly with regard to surgical planning. (orig.)

  5. Optimal relaxation parameters of DRAMA (dynamic RAMLA) aiming at one-pass image reconstruction for 3D-PET

    Science.gov (United States)

    Tanaka, Eiichi; Kudo, Hiroyuki

    2010-05-01

    We have reported a block-iterative algorithm named DRAMA for image reconstruction for emission tomography (Tanaka and Kudo 2003 Phys. Med. Biol. 48 1405-22). DRAMA is a modified version of the row-action maximum likelihood algorithm (RAMLA), in which the relaxation parameter is subset dependent and is changed in such a way that the noise propagation from subsets to the reconstructed image is substantially independent of the access order of the subsets. The algorithm provides fast convergence with a reasonable signal-to-noise ratio. The optimal relaxation parameter has been derived assuming a two-dimensional (2D)-PET model, and detailed performance in three-dimensional (3D) reconstruction has not been clear enough. We have developed the new version 'DRAMA-3D', based on the 3D-PET model. The optimal relaxation parameter is a function of the access order of the subsets and the ring difference, and its value is determined by simple formulas from the design parameters of the PET scanner, the operating conditions and the post-smoothing resolution. In this paper, we present the theory of DRAMA-3D, the results of simulation studies on the performance of DRAMA-3D and the comparative studies of the related algorithms. It is shown that DRAMA-3D is robust for various access orders of subsets and is suitable to realize one-pass (single-iteration) reconstruction.

  6. AUTOMATIC TEXTURE RECONSTRUCTION OF 3D CITY MODEL FROM OBLIQUE IMAGES

    OpenAIRE

    Kang, Junhua; Deng, Fei; LI, XINWEI; WAN, FANG

    2016-01-01

    In recent years, the photorealistic 3D city models are increasingly important in various geospatial applications related to virtual city tourism, 3D GIS, urban planning, real-estate management. Besides the acquisition of high-precision 3D geometric data, texture reconstruction is also a crucial step for generating high-quality and visually realistic 3D models. However, most of the texture reconstruction approaches are probably leading to texture fragmentation and memory inefficiency....

  7. Fast implementations of 3D PET reconstruction using vector and parallel programming techniques

    International Nuclear Information System (INIS)

    Computationally intensive techniques that offer potential clinical use have arisen in nuclear medicine. Examples include iterative reconstruction, 3D PET data acquisition and reconstruction, and 3D image volume manipulation including image registration. One obstacle in achieving clinical acceptance of these techniques is the computational time required. This study focuses on methods to reduce the computation time for 3D PET reconstruction through the use of fast computer hardware, vector and parallel programming techniques, and algorithm optimization. The strengths and weaknesses of i860 microprocessor based workstation accelerator boards are investigated in implementations of 3D PET reconstruction

  8. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  9. Advanced system for 3D dental anatomy reconstruction and 3D tooth movement simulation during orthodontic treatment

    Science.gov (United States)

    Monserrat, Carlos; Alcaniz-Raya, Mariano L.; Juan, M. Carmen; Grau Colomer, Vincente; Albalat, Salvador E.

    1997-05-01

    This paper describes a new method for 3D orthodontics treatment simulation developed for an orthodontics planning system (MAGALLANES). We develop an original system for 3D capturing and reconstruction of dental anatomy that avoid use of dental casts in orthodontic treatments. Two original techniques are presented, one direct in which data are acquired directly form patient's mouth by mean of low cost 3D digitizers, and one mixed in which data are obtained by 3D digitizing of hydrocollids molds. FOr this purpose we have designed and manufactured an optimized optical measuring system based on laser structured light. We apply these 3D dental models to simulate 3D movement of teeth, including rotations, during orthodontic treatment. The proposed algorithms enable to quantify the effect of orthodontic appliance on tooth movement. The developed techniques has been integrated in a system named MAGALLANES. This original system present several tools for 3D simulation and planning of orthodontic treatments. The prototype system has been tested in several orthodontic clinic with very good results.

  10. 3D neutron computed tomography. Requirements and applications

    International Nuclear Information System (INIS)

    Other than X-rays, neutrons can penetrate most metals easily while delivering a high contrast for many light-weight elements. Especially their high sensitivity for hydrogen makes them a valuable tool for the detection of organic materials like lubricants, plastics or sealants within metal housings. Neutron radiography and tomography complement the application of X-ray for the inspection of complex and critical components like in automotive and aerospace applications. An overview about the technical and mathematical differences between neutron and X-ray tomography is given and the imperfections and limitations of a neutron setup are shown. Several examples of technical neutron computed tomography are given. (author)

  11. Regional application of multi-layer artificial neural networks in 3-D ionosphere tomography

    Science.gov (United States)

    Ghaffari Razin, Mir Reza; Voosoghi, Behzad

    2016-08-01

    Tomography is a very cost-effective method to study physical properties of the ionosphere. In this paper, residual minimization training neural network (RMTNN) is used in voxel-based tomography to reconstruct of 3-D ionosphere electron density with high spatial resolution. For numerical experiments, observations collected at 37 GPS stations from Iranian permanent GPS network (IPGN) are used. A smoothed TEC approach was used for absolute STEC recovery. To improve the vertical resolution, empirical orthogonal functions (EOFs) obtained from international reference ionosphere 2012 (IRI-2012) used as object function in training neural network. Ionosonde observations is used for validate reliability of the proposed method. Minimum relative error for RMTNN is 1.64% and maximum relative error is 15.61%. Also root mean square error (RMSE) of 0.17 × 1011 (electrons/m3) is computed for RMTNN which is less than RMSE of IRI2012. The results show that RMTNN has higher accuracy and compiles speed than other ionosphere reconstruction methods.

  12. DIII-D Equilibrium Reconstructions with New 3D Magnetic Probes

    Science.gov (United States)

    Lao, Lang; Strait, E. J.; Ferraro, N. M.; Ferron, J. R.; King, J. D.; Lee, X.; Meneghini, O.; Turnbull, A. D.; Huang, Y.; Qian, J. G.; Wingen, A.

    2015-11-01

    DIII-D equilibrium reconstructions with the recently installed new 3D magnetic diagnostic are presented. In addition to providing information to allow more accurate 2D reconstructions, the new 3D probes also provide useful information to guide computation of 3D perturbed equilibria. A new more comprehensive magnetic compensation has been implemented. Algorithms are being developed to allow EFIT to reconstruct 3D perturbed equilibria making use of the new 3D probes and plasma responses from 3D MHD codes such as GATO and M3D-C1. To improve the computation efficiency, all inactive probes in one of the toroidal planes in EFIT have been replaced with new probes from other planes. Other 3D efforts include testing of 3D reconstructions using V3FIT and a new 3D variational moment equilibrium code VMOM3D. Other EFIT developments include a GPU EFIT version and new safety factor and MSE-LS constraints. The accuracy and limitation of the new probes for 3D reconstructions will be discussed. Supported by US DOE under DE-FC02-04ER54698 and DE-FG02-95ER54309.

  13. Electron tomography based on a total variation minimization reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Goris, B., E-mail: bart.goris@ua.ac.be [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Van den Broek, W. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Batenburg, K.J. [Centrum Wiskunde and Informatica, Science Park 123, NL-1098XG Amsterdam (Netherlands); Vision Lab, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk (Belgium); Heidari Mezerji, H.; Bals, S. [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2012-02-15

    The 3D reconstruction of a tilt series for electron tomography is mostly carried out using the weighted backprojection (WBP) algorithm or using one of the iterative algorithms such as the simultaneous iterative reconstruction technique (SIRT). However, it is known that these reconstruction algorithms cannot compensate for the missing wedge. Here, we apply a new reconstruction algorithm for electron tomography, which is based on compressive sensing. This is a field in image processing specialized in finding a sparse solution or a solution with a sparse gradient to a set of ill-posed linear equations. Therefore, it can be applied to electron tomography where the reconstructed objects often have a sparse gradient at the nanoscale. Using a combination of different simulated and experimental datasets, it is shown that missing wedge artefacts are reduced in the final reconstruction. Moreover, it seems that the reconstructed datasets have a higher fidelity and are easier to segment in comparison to reconstructions obtained by more conventional iterative algorithms. -- Highlights: Black-Right-Pointing-Pointer A reconstruction algorithm for electron tomography is investigated based on total variation minimization. Black-Right-Pointing-Pointer Missing wedge artefacts are reduced by this algorithm. Black-Right-Pointing-Pointer The reconstruction is easier to segment. Black-Right-Pointing-Pointer More reliable quantitative information can be obtained.

  14. Improvement of geometrical measurements from 3D-SEM reconstructions

    DEFF Research Database (Denmark)

    Carli, Lorenzo; De Chiffre, Leonardo; Horsewell, Andy;

    2009-01-01

    The quantification of 3D geometry at the nanometric scale is a major metrological challenge. In this work geometrical measurements on cylindrical items obtained with a 3D-SEM were investigated. Two items were measured: a wire gauge having a 0.25 mm nominal diameter and a hypodermic needle having...... that the diameter estimation performed using the 3D-SEM leads to an overestimation of approx. 7% compared to the reference values obtained using a 1-D length measuring machine. Standard deviation of SEM measurements performed on the wire gauge is approx. 1.5 times lower than the one performed on the hypodermic...

  15. Integration of real-time 3D capture, reconstruction, and light-field display

    Science.gov (United States)

    Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao

    2015-03-01

    Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.

  16. 3D reconstruction of SEM images by use of optical photogrammetry software.

    Science.gov (United States)

    Eulitz, Mona; Reiss, Gebhard

    2015-08-01

    Reconstruction of the three-dimensional (3D) surface of an object to be examined is widely used for structure analysis in science and many biological questions require information about their true 3D structure. For Scanning Electron Microscopy (SEM) there has been no efficient non-destructive solution for reconstruction of the surface morphology to date. The well-known method of recording stereo pair images generates a 3D stereoscope reconstruction of a section, but not of the complete sample surface. We present a simple and non-destructive method of 3D surface reconstruction from SEM samples based on the principles of optical close range photogrammetry. In optical close range photogrammetry a series of overlapping photos is used to generate a 3D model of the surface of an object. We adapted this method to the special SEM requirements. Instead of moving a detector around the object, the object itself was rotated. A series of overlapping photos was stitched and converted into a 3D model using the software commonly used for optical photogrammetry. A rabbit kidney glomerulus was used to demonstrate the workflow of this adaption. The reconstruction produced a realistic and high-resolution 3D mesh model of the glomerular surface. The study showed that SEM micrographs are suitable for 3D reconstruction by optical photogrammetry. This new approach is a simple and useful method of 3D surface reconstruction and suitable for various applications in research and teaching.

  17. 3D optical phase reconstruction within PMMA samples using a spectral OCT system

    Science.gov (United States)

    Briones-R., Manuel d. J.; De La Torre-Ibarra, Manuel H.; Mendoza Santoyo, Fernando

    2015-08-01

    The optical coherence tomography (OCT) technique has proved to be a useful method in biomedical areas such as ophthalmology, dentistry, dermatology, among many others. In all these applications the main target is to reconstruct the internal structure of the samples from which the physician's expertise may recognize and diagnose the existence of a disease. Nowadays OCT has been applied one step further and is used to study the mechanics of some particular type of materials, where the resulting information involves more than just their internal structure and the measurement of parameters such as displacements, stress and strain. Here we report on a spectral OCT system used to image the internal 3D microstructure and displacement maps from a PMMA (Poly-methyl-methacrylate) sample, subjected to a deformation by a controlled three point bending and tilting. The internal mechanical response of the polymer is shown as consecutive 2D images.

  18. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    Science.gov (United States)

    Willey, T. M.; Champley, K.; Hodgin, R.; Lauderbach, L.; Bagge-Hansen, M.; May, C.; Sanchez, N.; Jensen, B. J.; Iverson, A.; van Buuren, T.

    2016-06-01

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. This work outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ˜80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst, the 2nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3rd frame captures the flyer in flight, while the 4th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.

  19. Towards 3D facial reconstruction from uncalibrated CCTV footage

    NARCIS (Netherlands)

    Dam, van Chris; Veldhuis, Raymond; Spreeuwers, Luuk

    2012-01-01

    Facial comparison in 2D is an accepted method in law enforcement and forensic investigation, but pose variations, varying light conditions and low resolution video data can reduce the evidential value of the comparison. Some of these problems might be solved by comparing 3D face models: a face model

  20. 3-D Virtual and Physical Reconstruction of Bendego Iron

    Science.gov (United States)

    Belmonte, S. L. R.; Zucolotto, M. E.; Fontes, R. C.; dos Santos, J. R. L.

    2012-09-01

    The use of 3D laser scanning to meteoritic to preserve the original shape of the meteorites before cutting and the facility of saved the datas in STL format (stereolithography) to print three-dimensional physical models and generate a digital replica.

  1. Robust 3D reconstruction system for human jaw modeling

    Science.gov (United States)

    Yamany, Sameh M.; Farag, Aly A.; Tazman, David; Farman, Allan G.

    1999-03-01

    This paper presents a model-based vision system for dentistry that will replace traditional approaches used in diagnosis, treatment planning and surgical simulation. Dentistry requires accurate 3D representation of the teeth and jaws for many diagnostic and treatment purposes. For example orthodontic treatment involves the application of force systems to teeth over time to correct malocclusion. In order to evaluate tooth movement progress, the orthodontists monitors this movement by means of visual inspection, intraoral measurements, fabrication of plastic models, photographs and radiographs, a process which is both costly and time consuming. In this paper an integrate system has been developed to record the patient's occlusion using computer vision. Data is acquired with an intraoral video camera. A modified shape from shading (SFS) technique, using perspective projection and camera calibration, is used to extract accurate 3D information from a sequence of 2D images of the jaw. A new technique for 3D data registration, using a Grid Closest Point transform and genetic algorithms, is used to register the SFS output. Triangulization is then performed, and a solid 3D model is obtained via a rapid prototype machine.

  2. Online reconstruction of 3D magnetic particle imaging data

    Science.gov (United States)

    Knopp, T.; Hofmann, M.

    2016-06-01

    Magnetic particle imaging is a quantitative functional imaging technique that allows imaging of the spatial distribution of super-paramagnetic iron oxide particles at high temporal resolution. The raw data acquisition can be performed at frame rates of more than 40 volumes s‑1. However, to date image reconstruction is performed in an offline step and thus no direct feedback is available during the experiment. Considering potential interventional applications such direct feedback would be mandatory. In this work, an online reconstruction framework is implemented that allows direct visualization of the particle distribution on the screen of the acquisition computer with a latency of about 2 s. The reconstruction process is adaptive and performs block-averaging in order to optimize the signal quality for a given amount of reconstruction time.

  3. Autonomous Planetary 3-D Reconstruction From Satellite Images

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    A common task for many deep space missions is autonomous generation of 3-D representations of planetary surfaces onboard unmanned spacecrafts. The basic problem for this class of missions is, that the closed loop time is far too long. The closed loop time is defined as the time from when a human...... of seconds to a few minutes, the closed loop time effectively precludes active human control.The only way to circumvent this problem is to build an artificial feature extractor operating autonomously onboard the spacecraft.Different artificial feature extractors are presented and their efficiency...... is discussed.Based on such features, 3-D representations may be compiled from two or more 2-D satellite images. The main purposes of such a mapping system are extraction of landing sites, objects of scientific interest and general planetary surveying. All data processing is performed autonomously onboard...

  4. 3D reconstruction of tropospheric cirrus clouds by stereovision system

    Science.gov (United States)

    Nadjib Kouahla, Mohamed; Moreels, Guy; Seridi, Hamid

    2016-07-01

    A stereo imaging method is applied to measure the altitude of cirrus clouds and provide a 3D map of the altitude of the layer centroid. They are located in the high troposphere and, sometimes in the lower stratosphere, between 6 and 10 km high. Two simultaneous images of the same scene are taken with Canon cameras (400D) in two sites distant of 37 Km. Each image processed in order to invert the perspective effect and provide a satellite-type view of the layer. Pairs of matched points that correspond to a physical emissive point in the common area are identified in calculating a correlation coefficient (ZNCC: Zero mean Normalized Cross-correlation or ZSSD: as Zero mean Sum of Squared Differences). This method is suitable for obtaining 3D representations in the case of low-contrast objects. An observational campaign was conducted in June 2014 in France. The images were taken simultaneously at Marnay (47°17'31.5" N, 5°44'58.8" E; altitude 275 m) 25 km northwest of Besancon and in Mont poupet (46°58'31.5" N, 5°52'22.7" E; altitude 600 m) southwest of Besancon at 43 km. 3D maps of the Natural cirrus clouds and artificial like "aircraft trails" are retrieved. They are compared with pseudo-relief intensity maps of the same region. The mean altitude of the cirrus barycenter is located at 8.5 ± 1km on June 11.

  5. 3-D Reconstruction From 2-D Radiographic Images and Its Application to Clinical Veterinary Medicine

    Science.gov (United States)

    Hamamoto, Kazuhiko; Sato, Motoyoshi

    3D imaging technique is very important and indispensable in diagnosis. The main stream of the technique is one in which 3D image is reconstructed from a set of slice images, such as X-ray CT and MRI. However, these systems require large space and high costs. On the other hand, a low cost and small size 3D imaging system is needed in clinical veterinary medicine, for example, in the case of diagnosis in X-ray car or pasture area. We propose a novel 3D imaging technique using 2-D X-ray radiographic images. This system can be realized by cheaper system than X-ray CT and enables to get 3D image in X-ray car or portable X-ray equipment. In this paper, a 3D visualization technique from 2-D radiographic images is proposed and several reconstructions are shown. These reconstructions are evaluated by veterinarians.

  6. 3D reconstruction of worn parts for flexible remanufacture based on robotic arc welding

    Institute of Scientific and Technical Information of China (English)

    Yin Ziqiang; Zhang Guangjun; Gao Hongming; Wu Lin

    2010-01-01

    3D reconstruction of worn parts is the foundation for remanufacturing system based on robotic arc welding,because it can provide 3D geometric information for robot task plan.In this investigation,a nocwl 3D reconstruction system based on linear structured light vision sensing is developed,This system hardware consists of a MTC368-CB CCD camera,a MLH-645laser projector and a DH-CG300 image grabbing card.This system software is developed to control the image data capture.In order to reconstruct the 3D geometric information from the captured image,a two steps rapid calibration algorithm is proposed.The 3D reconstruction experiment shows a satisfactory result.

  7. Experimental Investigation of Material Flows Within FSWs Using 3D Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Charles R. Tolle; Timothy A. White; Karen S. Miller; Denis E. Clark; Herschel B. Smartt

    2008-06-01

    There exists significant prior work using tracers or pre-placed hardened markers within friction stir welding (FSWing) to experimentally explore material flow within the FSW process. Our experiments replaced markers with a thin sheet of copper foil placed between the 6061 aluminum lap and butt joints that were then welded. The absorption characteristics of x-rays for copper and aluminum are significantly different allowing for non-destructive evaluation (NDE) methods such as x-ray computed tomography (CT) to be used to demonstrate the material movement within the weldment on a much larger scale than previously shown. 3D CT reconstruction of the copper components of the weldment allows for a unique view into the final turbulent state of the welding process as process parameters are varied. The x-ray CT data of a section of the weld region was collected using a cone-beam x-ray imaging system developed at the INL. Six-hundred projections were collected over 360-degrees using a 160-kVp Bremsstrahlung x-ray generator (25-micrometer focal spot) and amorphoussilicon x-ray detector. The region of the object that was imaged was about 3cm tall and 1.5cm x 1cm in cross section, and was imaged at a magnification of about 3.6x. The data were reconstructed on a 0.5x0.5x0.5 mm3 voxel grid. After reconstruction, the aluminum and copper could be easily discriminated using a gray level threshold allowing visualization of the copper components. Fractal analysis of the tomographic reconstructed material topology is investigated as a means to quantify macro level material flow based on process parameters. The results of multi-pass FSWs show increased refinement of the copper trace material. Implications of these techniques for quantifying process flow are discussed.

  8. Large area 3-D optical coherence tomography imaging of lumpectomy specimens for radiation treatment planning

    Science.gov (United States)

    Wang, Cuihuan; Kim, Leonard; Barnard, Nicola; Khan, Atif; Pierce, Mark C.

    2016-02-01

    Our long term goal is to develop a high-resolution imaging method for comprehensive assessment of tissue removed during lumpectomy procedures. By identifying regions of high-grade disease within the excised specimen, we aim to develop patient-specific post-operative radiation treatment regimens. We have assembled a benchtop spectral-domain optical coherence tomography (SD-OCT) system with 1320 nm center wavelength. Automated beam scanning enables "sub-volumes" spanning 5 mm x 5 mm x 2 mm (500 A-lines x 500 B-scans x 2 mm in depth) to be collected in under 15 seconds. A motorized sample positioning stage enables multiple sub-volumes to be acquired across an entire tissue specimen. Sub-volumes are rendered from individual B-scans in 3D Slicer software and en face (XY) images are extracted at specific depths. These images are then tiled together using MosaicJ software to produce a large area en face view (up to 40 mm x 25 mm). After OCT imaging, specimens were sectioned and stained with HE, allowing comparison between OCT image features and disease markers on histopathology. This manuscript describes the technical aspects of image acquisition and reconstruction, and reports initial qualitative comparison between large area en face OCT images and HE stained tissue sections. Future goals include developing image reconstruction algorithms for mapping an entire sample, and registering OCT image volumes with clinical CT and MRI images for post-operative treatment planning.

  9. Method for 3D fibre reconstruction on a microrobotic platform.

    Science.gov (United States)

    Hirvonen, J; Myllys, M; Kallio, P

    2016-07-01

    Automated handling of a natural fibrous object requires a method for acquiring the three-dimensional geometry of the object, because its dimensions cannot be known beforehand. This paper presents a method for calculating the three-dimensional reconstruction of a paper fibre on a microrobotic platform that contains two microscope cameras. The method is based on detecting curvature changes in the fibre centreline, and using them as the corresponding points between the different views of the images. We test the developed method with four fibre samples and compare the results with the references measured with an X-ray microtomography device. We rotate the samples through 16 different orientations on the platform and calculate the three-dimensional reconstruction to test the repeatability of the algorithm and its sensitivity to the orientation of the sample. We also test the noise sensitivity of the algorithm, and record the mismatch rate of the correspondences provided. We use the iterative closest point algorithm to align the measured three-dimensional reconstructions with the references. The average point-to-point distances between the reconstructed fibre centrelines and the references are 20-30 μm, and the mismatch rate is low. Given the manipulation tolerance, this shows that the method is well suited to automated fibre grasping. This has also been demonstrated with actual grasping experiments. PMID:26695385

  10. 3D model tools for architecture and archaeology reconstruction

    Science.gov (United States)

    Vlad, Ioan; Herban, Ioan Sorin; Stoian, Mircea; Vilceanu, Clara-Beatrice

    2016-06-01

    The main objective of architectural and patrimonial survey is to provide a precise documentation of the status quo of the surveyed objects (monuments, buildings, archaeological object and sites) for preservation and protection, for scientific studies and restoration purposes, for the presentation to the general public. Cultural heritage documentation includes an interdisciplinary approach having as purpose an overall understanding of the object itself and an integration of the information which characterize it. The accuracy and the precision of the model are directly influenced by the quality of the measurements realized on field and by the quality of the software. The software is in the process of continuous development, which brings many improvements. On the other side, compared to aerial photogrammetry, close range photogrammetry and particularly architectural photogrammetry is not limited to vertical photographs with special cameras. The methodology of terrestrial photogrammetry has changed significantly and various photographic acquisitions are widely in use. In this context, the present paper brings forward a comparative study of TLS (Terrestrial Laser Scanner) and digital photogrammetry for 3D modeling. The authors take into account the accuracy of the 3D models obtained, the overall costs involved for each technology and method and the 4th dimension - time. The paper proves its applicability as photogrammetric technologies are nowadays used at a large scale for obtaining the 3D model of cultural heritage objects, efficacious in their assessment and monitoring, thus contributing to historic conservation. Its importance also lies in highlighting the advantages and disadvantages of each method used - very important issue for both the industrial and scientific segment when facing decisions such as in which technology to invest more research and funds.

  11. Quantitative Reconstructions of 3D Chemical Nanostructures in Nanowires.

    Science.gov (United States)

    Rueda-Fonseca, P; Robin, E; Bellet-Amalric, E; Lopez-Haro, M; Den Hertog, M; Genuist, Y; André, R; Artioli, A; Tatarenko, S; Ferrand, D; Cibert, J

    2016-03-01

    Energy dispersive X-ray spectrometry is used to extract a quantitative 3D composition profile of heterostructured nanowires. The analysis of hypermaps recorded along a limited number of projections, with a preliminary calibration of the signal associated with each element, is compared to the intensity profiles calculated for a model structure with successive shells of circular, elliptic, or faceted cross sections. This discrete tomographic technique is applied to II-VI nanowires grown by molecular beam epitaxy, incorporating ZnTe and CdTe and their alloys with Mn and Mg, with typical size down to a few nanometers and Mn or Mg content as low as 10%. PMID:26837636

  12. 3D Image Reconstruction from Compton camera data

    CERN Document Server

    Kuchment, Peter

    2016-01-01

    In this paper, we address analytically and numerically the inversion of the integral transform (\\emph{cone} or \\emph{Compton} transform) that maps a function on $\\mathbb{R}^3$ to its integrals over conical surfaces. It arises in a variety of imaging techniques, e.g. in astronomy, optical imaging, and homeland security imaging, especially when the so called Compton cameras are involved. Several inversion formulas are developed and implemented numerically in $3D$ (the much simpler $2D$ case was considered in a previous publication).

  13. Quantitative Reconstructions of 3D Chemical Nanostructures in Nanowires.

    Science.gov (United States)

    Rueda-Fonseca, P; Robin, E; Bellet-Amalric, E; Lopez-Haro, M; Den Hertog, M; Genuist, Y; André, R; Artioli, A; Tatarenko, S; Ferrand, D; Cibert, J

    2016-03-01

    Energy dispersive X-ray spectrometry is used to extract a quantitative 3D composition profile of heterostructured nanowires. The analysis of hypermaps recorded along a limited number of projections, with a preliminary calibration of the signal associated with each element, is compared to the intensity profiles calculated for a model structure with successive shells of circular, elliptic, or faceted cross sections. This discrete tomographic technique is applied to II-VI nanowires grown by molecular beam epitaxy, incorporating ZnTe and CdTe and their alloys with Mn and Mg, with typical size down to a few nanometers and Mn or Mg content as low as 10%.

  14. Reconstruction of 3D models of cast sculptures using close-range photogrammetry

    Directory of Open Access Journals (Sweden)

    Ž. Santoši

    2015-10-01

    Full Text Available This paper presents the possibilities of application of close-range photogrammetry, based on the Structure-from- Motion (SfM approach, in 3D model’s reconstruction of bronze cast sculptures. Special attention was dedicated to the analysis of image processing strategy, and its impact on the 3D model reconstruction quality. For the purpose of analysis a bust of Nikola Tesla, placed in front of the Faculty of Technical Sciences University of Novi Sad was used. Experimental results indicate that the strategy employing multi-group photo processing provides substantial reductions in processing time while providing satisfactory results in 3D reconstruction.

  15. 3-D Adaptive Sparsity Based Image Compression With Applications to Optical Coherence Tomography.

    Science.gov (United States)

    Fang, Leyuan; Li, Shutao; Kang, Xudong; Izatt, Joseph A; Farsiu, Sina

    2015-06-01

    We present a novel general-purpose compression method for tomographic images, termed 3D adaptive sparse representation based compression (3D-ASRC). In this paper, we focus on applications of 3D-ASRC for the compression of ophthalmic 3D optical coherence tomography (OCT) images. The 3D-ASRC algorithm exploits correlations among adjacent OCT images to improve compression performance, yet is sensitive to preserving their differences. Due to the inherent denoising mechanism of the sparsity based 3D-ASRC, the quality of the compressed images are often better than the raw images they are based on. Experiments on clinical-grade retinal OCT images demonstrate the superiority of the proposed 3D-ASRC over other well-known compression methods. PMID:25561591

  16. Practical limitations of cone-beam computed tomography in 3D cephalometry%Practical limitations of cone-beam computed tomography in3D cephalometry

    Institute of Scientific and Technical Information of China (English)

    Janalt Damstra; Zacharias Fourie; Yijin Ren

    2011-01-01

    3D cone beam computed tomography (CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs.However,in almost all aspects of CBCT imaging,from utilization to application,inherent limitations and pitfalls exist.Importantly,these inherent limitations and pitfalls have practical implications which need to be addressed before the potential of this technology can be fully realized.The purpose of this review was to explore the current limitations and pitfalls associated with CBCT imaging to allow for better and more accurate understanding of the possibilities this imaging modality could offer,particularly pertaining to 3D cephalometry.

  17. Assessing 3D tunnel position in ACL reconstruction using a novel single image 3D-2D registration

    Science.gov (United States)

    Kang, X.; Yau, W. P.; Otake, Y.; Cheung, P. Y. S.; Hu, Y.; Taylor, R. H.

    2012-02-01

    The routinely used procedure for evaluating tunnel positions following anterior cruciate ligament (ACL) reconstructions based on standard X-ray images is known to pose difficulties in terms of obtaining accurate measures, especially in providing three-dimensional tunnel positions. This is largely due to the variability in individual knee joint pose relative to X-ray plates. Accurate results were reported using postoperative CT. However, its extensive usage in clinical routine is hampered by its major requirement of having CT scans of individual patients, which is not available for most ACL reconstructions. These difficulties are addressed through the proposed method, which aligns a knee model to X-ray images using our novel single-image 3D-2D registration method and then estimates the 3D tunnel position. In the proposed method, the alignment is achieved by using a novel contour-based 3D-2D registration method wherein image contours are treated as a set of oriented points. However, instead of using some form of orientation weighting function and multiplying it with a distance function, we formulate the 3D-2D registration as a probability density estimation using a mixture of von Mises-Fisher-Gaussian (vMFG) distributions and solve it through an expectation maximization (EM) algorithm. Compared with the ground-truth established from postoperative CT, our registration method in an experiment using a plastic phantom showed accurate results with errors of (-0.43°+/-1.19°, 0.45°+/-2.17°, 0.23°+/-1.05°) and (0.03+/-0.55, -0.03+/-0.54, -2.73+/-1.64) mm. As for the entry point of the ACL tunnel, one of the key measurements, it was obtained with high accuracy of 0.53+/-0.30 mm distance errors.

  18. 3D reconstruction software comparison for short sequences

    Science.gov (United States)

    Strupczewski, Adam; Czupryński, BłaŻej

    2014-11-01

    Large scale multiview reconstruction is recently a very popular area of research. There are many open source tools that can be downloaded and run on a personal computer. However, there are few, if any, comparisons between all the available software in terms of accuracy on small datasets that a single user can create. The typical datasets for testing of the software are archeological sites or cities, comprising thousands of images. This paper presents a comparison of currently available open source multiview reconstruction software for small datasets. It also compares the open source solutions with a simple structure from motion pipeline developed by the authors from scratch with the use of OpenCV and Eigen libraries.

  19. Identification and classification in le fort type fractures by using 2D and 3D computed tomography

    Institute of Scientific and Technical Information of China (English)

    CHEN We-jian; YANG Yun-jun; FANG Yi-ming; XU Fang-hong; ZHANG Lin; CAO Guo-quan

    2006-01-01

    Objective:To evaluate the usefulness of twodimensional (2D) and three-dimensional (3D) computed tomography (CT) in the identification and classification of Le Fort type fractures.Methods: Sixty-two patients with different types of Le Fort fractures underwent CT scanning and 3D-CT reconstruction. The data were analyzed by multiplanar reconstruction (MPR), surface shaded display (SSD) and volume rendering (VR) respectively.Results: The patients with Le Fort Ⅰ , Le Fort Ⅱfracture and Le Fort Ⅲ fracture accounted for 16.1%,14.5 % and 12.9 % respectively. The compound fractures were the most common type and accounted for 56.5 % ( n =35, 18 cases with Le Fort Ⅰ + Ⅱ fracture, 10 cases with Le Fort Ⅱ + Ⅲ fracture and 7 cases with Le Fort Ⅰ + Ⅱ + Ⅲfracture). Fifty-five cases coexisted with other fractures in maxillofacial region. 2D-CT could be used to define the tiny fractures and the deep-structure fractures more accurately compared with 3D-CT, but the real impression of Le Fort type fractures could not be correctly evaluated on 2D-CT.3D-CT could clearly demonstrate the whole shape of Le Fort type fractures and identify the classification of Le Fort fractures.Conclusions: 3D-CT is the best imaging method for the diagnosis of Le Fort type fractures and can provide valuable information of space relationship, especially for the design of treatment plan before operation.

  20. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  1. Manifold Constrained Transfer of Facial Geometric Knowledge for 3D Caricature Reconstruction

    Institute of Scientific and Technical Information of China (English)

    Jun-Fa Liu; Wen-Jing He; Tao Chen; Yi-Qiang Chen

    2013-01-01

    3D caricatures are important attractive elements of the interface in virtual environment such as online game.However,very limited 3D caricatures exist in the real world.Meanwhile,creating 3D caricatures manually is rather costly,and even professional skills are needed.This paper proposes a novel and effective manifold transfer algorithm to reconstruct 3D caricatures according to their original 2D caricatures.We first manually create a small dataset with only 100 3D caricature models and use them to initialize the whole 3D dataset.After that,manifold transfer algorithm is carried out to refine the dataset.The algorithm comprises of two steps.The first is to perform manifold alignment between 2D and 3D caricatures to get a "standard" manifold map; the second is to reconstruct all the 3D caricatures based on the manifold map.The proposed approach utilizes and transfers knowledge of 2D caricatures to the target 3D caricatures well.Comparative experiments show that the approach reconstructs 3D caricatures more effectively and the results conform more to the styles of the original 2D caricatures than the Principal Components Analysis (PCA) based method.

  2. Assist feature printability prediction by 3-D resist profile reconstruction

    Science.gov (United States)

    Zheng, Xin; Huang, Jensheng; Chin, Fook; Kazarian, Aram; Kuo, Chun-Chieh

    2012-06-01

    properties may then be used to optimize the printability vs. efficacy of an SRAF either prior to or during an Optical Proximity Correction (OPC) run. The process models that are used during OPC have never been able to reliably predict which SRAFs will print. This appears to be due to the fact that OPC process models are generally created using data that does not include printed subresolution patterns. An enhancement to compact modeling capability to predict Assist Features (AF) printability is developed and discussed. A hypsometric map representing 3-D resist profile was built by applying a first principle approximation to estimate the "energy loss" from the resist top to bottom. Such a 3-D resist profile is an extrapolation of a well calibrated traditional OPC model without any additional information. Assist features are detected at either top of resist (dark field) or bottom of resist (bright field). Such detection can be done by just extracting top or bottom resist models from our 3-D resist model. There is no measurement of assist features needed when we build AF but it can be included if interested but focusing on resist calibration to account for both exposure dosage and focus change sensitivities. This approach significantly increases resist model's capability for predicting printed SRAF accuracy. And we don't need to calibrate an SRAF model in addition to the OPC model. Without increase in computation time, this compact model can draw assist feature contour with real placement and size at any vertical plane. The result is compared and validated with 3-D rigorous modeling as well as SEM images. Since this method does not change any form of compact modeling, it can be integrated into current MBAF solutions without any additional work.

  3. Digital Holographic Capture and Optoelectronic Reconstruction for 3D Displays

    Directory of Open Access Journals (Sweden)

    Damien P. Kelly

    2010-01-01

    Full Text Available The application of digital holography as a viable solution to 3D capture and display technology is examined. A review of the current state of the field is presented in which some of the major challenges involved in a digital holographic solution are highlighted. These challenges include (i the removal of the DC and conjugate image terms, which are features of the holographic recording process, (ii the reduction of speckle noise, a characteristic of a coherent imaging process, (iii increasing the angular range of perspective of digital holograms (iv and replaying captured and/or processed digital holograms using spatial light modulators. Each of these challenges are examined theoretically and several solutions are put forward. Experimental results are presented that demonstrate the validity of the theoretical solutions.

  4. Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Ja [Graduate School of Clinical Dentistry, Hallym University, Seoul (Korea, Republic of); Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-03-15

    This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

  5. Combinatorial clustering and Its Application to 3D Polygonal Traffic Sign Reconstruction From Multiple Images

    Science.gov (United States)

    Vallet, B.; Soheilian, B.; Brédif, M.

    2014-08-01

    The 3D reconstruction of similar 3D objects detected in 2D faces a major issue when it comes to grouping the 2D detections into clusters to be used to reconstruct the individual 3D objects. Simple clustering heuristics fail as soon as similar objects are close. This paper formulates a framework to use the geometric quality of the reconstruction as a hint to do a proper clustering. We present a methodology to solve the resulting combinatorial optimization problem with some simplifications and approximations in order to make it tractable. The proposed method is applied to the reconstruction of 3D traffic signs from their 2D detections to demonstrate its capacity to solve ambiguities.

  6. Efficient and robust 3D CT image reconstruction based on total generalized variation regularization using the alternating direction method.

    Science.gov (United States)

    Chen, Jianlin; Wang, Linyuan; Yan, Bin; Zhang, Hanming; Cheng, Genyang

    2015-01-01

    Iterative reconstruction algorithms for computed tomography (CT) through total variation regularization based on piecewise constant assumption can produce accurate, robust, and stable results. Nonetheless, this approach is often subject to staircase artefacts and the loss of fine details. To overcome these shortcomings, we introduce a family of novel image regularization penalties called total generalized variation (TGV) for the effective production of high-quality images from incomplete or noisy projection data for 3D reconstruction. We propose a new, fast alternating direction minimization algorithm to solve CT image reconstruction problems through TGV regularization. Based on the theory of sparse-view image reconstruction and the framework of augmented Lagrange function method, the TGV regularization term has been introduced in the computed tomography and is transformed into three independent variables of the optimization problem by introducing auxiliary variables. This new algorithm applies a local linearization and proximity technique to make the FFT-based calculation of the analytical solutions in the frequency domain feasible, thereby significantly reducing the complexity of the algorithm. Experiments with various 3D datasets corresponding to incomplete projection data demonstrate the advantage of our proposed algorithm in terms of preserving fine details and overcoming the staircase effect. The computation cost also suggests that the proposed algorithm is applicable to and is effective for CBCT imaging. Theoretical and technical optimization should be investigated carefully in terms of both computation efficiency and high resolution of this algorithm in application-oriented research.

  7. Bayesian 3D velocity field reconstruction with VIRBIUS

    Science.gov (United States)

    Lavaux, Guilhem

    2016-03-01

    I describe a new Bayesian-based algorithm to infer the full three dimensional velocity field from observed distances and spectroscopic galaxy catalogues. In addition to the velocity field itself, the algorithm reconstructs true distances, some cosmological parameters and specific non-linearities in the velocity field. The algorithm takes care of selection effects, miscalibration issues and can be easily extended to handle direct fitting of e.g. the inverse Tully-Fisher relation. I first describe the algorithm in details alongside its performances. This algorithm is implemented in the VIRBIUS (VelocIty Reconstruction using Bayesian Inference Software) software package. I then test it on different mock distance catalogues with a varying complexity of observational issues. The model proved to give robust measurement of velocities for mock catalogues of 3000 galaxies. I expect the core of the algorithm to scale to tens of thousands galaxies. It holds the promises of giving a better handle on future large and deep distance surveys for which individual errors on distance would impede velocity field inference.

  8. Bayesian 3d velocity field reconstruction with VIRBIuS

    CERN Document Server

    Lavaux, G

    2015-01-01

    I describe a new Bayesian based algorithm to infer the full three dimensional velocity field from observed distances and spectroscopic galaxy catalogues. In addition to the velocity field itself, the algorithm reconstructs true distances, some cosmological parameters and specific non-linearities in the velocity field. The algorithm takes care of selection effects, miscalibration issues and can be easily extended to handle direct fitting of, e.g., the inverse Tully-Fisher relation. I first describe the algorithm in details alongside its performances. This algorithm is implemented in the VIRBIuS (VelocIty Reconstruction using Bayesian Inference Software) software package. I then test it on different mock distance catalogues with a varying complexity of observational issues. The model proved to give robust measurement of velocities for mock catalogues of 3,000 galaxies. I expect the core of the algorithm to scale to tens of thousands galaxies. It holds the promises of giving a better handle on future large and d...

  9. GPU-Based 3D Cone-Beam CT Image Reconstruction for Large Data Volume

    OpenAIRE

    Xing Zhao; Jing-jing Hu; Peng Zhang

    2009-01-01

    Currently, 3D cone-beam CT image reconstruction speed is still a severe limitation for clinical application. The computational power of modern graphics processing units (GPUs) has been harnessed to provide impressive acceleration of 3D volume image reconstruction. For extra large data volume exceeding the physical graphic memory of GPU, a straightforward compromise is to divide data volume into blocks. Different from the conventional Octree partition method, a new partition scheme is proposed...

  10. Reconstructing 3D building models from laser scanning to calculate the heat demand

    Energy Technology Data Exchange (ETDEWEB)

    Neidhart, Hauke; Sester, Monika

    2008-09-15

    The objective of the project is to determine the heat demand of settlement areas using geospatial data, especially airborne laser scanning data. With airborne laser scanning it possible to record detailed 3D data for great areas. With this 3D data it is possible to reconstruct 3D building models. The geometry then can be used to derive information for the calculation of the heat demand

  11. 3D Ultrastructural organization of whole Chlamydomonas reinhardtii cells studied by nanoscale soft x-ray tomography.

    Directory of Open Access Journals (Sweden)

    Eric Hummel

    Full Text Available The complex architecture of their structural elements and compartments is a hallmark of eukaryotic cells. The creation of high resolution models of whole cells has been limited by the relatively low resolution of conventional light microscopes and the requirement for ultrathin sections in transmission electron microscopy. We used soft x-ray tomography to study the 3D ultrastructural organization of whole cells of the unicellular green alga Chlamydomonas reinhardtii at unprecedented spatial resolution. Intact frozen hydrated cells were imaged using the natural x-ray absorption contrast of the sample without any staining. We applied different fiducial-based and fiducial-less alignment procedures for the 3D reconstructions. The reconstructed 3D volumes of the cells show features down to 30 nm in size. The whole cell tomograms reveal ultrastructural details such as nuclear envelope membranes, thylakoids, basal apparatus, and flagellar microtubule doublets. In addition, the x-ray tomograms provide quantitative data from the cell architecture. Therefore, nanoscale soft x-ray tomography is a new valuable tool for numerous qualitative and quantitative applications in plant cell biology.

  12. Automatic Texture Reconstruction of 3d City Model from Oblique Images

    Science.gov (United States)

    Kang, Junhua; Deng, Fei; Li, Xinwei; Wan, Fang

    2016-06-01

    In recent years, the photorealistic 3D city models are increasingly important in various geospatial applications related to virtual city tourism, 3D GIS, urban planning, real-estate management. Besides the acquisition of high-precision 3D geometric data, texture reconstruction is also a crucial step for generating high-quality and visually realistic 3D models. However, most of the texture reconstruction approaches are probably leading to texture fragmentation and memory inefficiency. In this paper, we introduce an automatic framework of texture reconstruction to generate textures from oblique images for photorealistic visualization. Our approach include three major steps as follows: mesh parameterization, texture atlas generation and texture blending. Firstly, mesh parameterization procedure referring to mesh segmentation and mesh unfolding is performed to reduce geometric distortion in the process of mapping 2D texture to 3D model. Secondly, in the texture atlas generation step, the texture of each segmented region in texture domain is reconstructed from all visible images with exterior orientation and interior orientation parameters. Thirdly, to avoid color discontinuities at boundaries between texture regions, the final texture map is generated by blending texture maps from several corresponding images. We evaluated our texture reconstruction framework on a dataset of a city. The resulting mesh model can get textured by created texture without resampling. Experiment results show that our method can effectively mitigate the occurrence of texture fragmentation. It is demonstrated that the proposed framework is effective and useful for automatic texture reconstruction of 3D city model.

  13. "High-precision, reconstructed 3D model" of skull scanned by conebeam CT: Reproducibility verified using CAD/CAM data.

    Science.gov (United States)

    Katsumura, Seiko; Sato, Keita; Ikawa, Tomoko; Yamamura, Keiko; Ando, Eriko; Shigeta, Yuko; Ogawa, Takumi

    2016-01-01

    Computed tomography (CT) scanning has recently been introduced into forensic medicine and dentistry. However, the presence of metal restorations in the dentition can adversely affect the quality of three-dimensional reconstruction from CT scans. In this study, we aimed to evaluate the reproducibility of a "high-precision, reconstructed 3D model" obtained from a conebeam CT scan of dentition, a method that might be particularly helpful in forensic medicine. We took conebeam CT and helical CT images of three dry skulls marked with 47 measuring points; reconstructed three-dimensional images; and measured the distances between the points in the 3D images with a computer-aided design/computer-aided manufacturing (CAD/CAM) marker. We found that in comparison with the helical CT, conebeam CT is capable of reproducing measurements closer to those obtained from the actual samples. In conclusion, our study indicated that the image-reproduction from a conebeam CT scan was more accurate than that from a helical CT scan. Furthermore, the "high-precision reconstructed 3D model" facilitates reliable visualization of full-sized oral and maxillofacial regions in both helical and conebeam CT scans. PMID:26832374

  14. 3-D reconstructions of the early-November 2004 CDAW geomagnetic storms: analysis of Ooty IPS speed and density data

    Directory of Open Access Journals (Sweden)

    M. M. Bisi

    2009-12-01

    Full Text Available Interplanetary scintillation (IPS remote-sensing observations provide a view of the solar wind covering a wide range of heliographic latitudes and heliocentric distances from the Sun between ~0.1 AU and 3.0 AU. Such observations are used to study the development of solar coronal transients and the solar wind while propagating out through interplanetary space. They can also be used to measure the inner-heliospheric response to the passage of coronal mass ejections (CMEs and co-rotating heliospheric structures. IPS observations can, in general, provide a speed estimate of the heliospheric material crossing the observing line of site; some radio antennas/arrays can also provide a radio scintillation level. We use a three-dimensional (3-D reconstruction technique which obtains perspective views from outward-flowing solar wind and co-rotating structure as observed from Earth by iteratively fitting a kinematic solar wind model to these data. Using this 3-D modelling technique, we are able to reconstruct the velocity and density of CMEs as they travel through interplanetary space. For the time-dependent model used here with IPS data taken from the Ootacamund (Ooty Radio Telescope (ORT in India, the digital resolution of the tomography is 10° by 10° in both latitude and longitude with a half-day time cadence. Typically however, the resolutions range from 10° to 20° in latitude and longitude, with a half- to one-day time cadence for IPS data dependant upon how much data are used as input to the tomography. We compare reconstructed structures during early-November 2004 with in-situ measurements from the Wind spacecraft orbiting the Sun-Earth L1-Point to validate the 3-D tomographic reconstruction results and comment on how these improve upon prior reconstructions.

  15. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    NARCIS (Netherlands)

    X. Liang; I. Lambrichts; Y. Sun; K. Denis; B. Hassan; L. Li; R. Pauwels; R. Jacobs

    2010-01-01

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G,

  16. Neural Network Based Reconstruction of a 3D Object from a 2D Wireframe

    CERN Document Server

    Johnson, Kyle; Lipson, Hod

    2010-01-01

    We propose a new approach for constructing a 3D representation from a 2D wireframe drawing. A drawing is simply a parallel projection of a 3D object onto a 2D surface; humans are able to recreate mental 3D models from 2D representations very easily, yet the process is very difficult to emulate computationally. We hypothesize that our ability to perform this construction relies on the angles in the 2D scene, among other geometric properties. Being able to reproduce this reconstruction process automatically would allow for efficient and robust 3D sketch interfaces. Our research focuses on the relationship between 2D geometry observable in the sketch and 3D geometry derived from a potential 3D construction. We present a fully automated system that constructs 3D representations from 2D wireframes using a neural network in conjunction with a genetic search algorithm.

  17. Image Reconstruction from 2D stack of MRI/CT to 3D using Shapelets

    OpenAIRE

    Arathi T; Latha Parameswaran

    2014-01-01

    Image reconstruction is an active research field, due to the increasing need for geometric 3D models in movie industry, games, virtual environments and in medical fields. 3D image reconstruction aims to arrive at the 3D model of an object, from its 2D images taken at different viewing angles. Medical images are multimodal, which includes MRI, CT scan image, PET and SPECT images. Of these, MRI and CT scan images of an organ when taken, is available as a stack of 2D images, taken at different a...

  18. Understanding Plasticity and Fracture in Aluminum Alloys and their Composites by 3D X-ray Synchrotron Tomography and Microdiffraction

    Science.gov (United States)

    Hruby, Peter

    Aluminum alloys and their composites are attractive materials for applications requiring high strength-to-weight ratios and reasonable cost. Many of these applications, such as those in the aerospace industry, undergo fatigue loading. An understanding of the microstructural damage that occurs in these materials is critical in assessing their fatigue resistance. Two distinct experimental studies were performed to further the understanding of fatigue damage mechanisms in aluminum alloys and their composites, specifically fracture and plasticity. Fatigue resistance of metal matrix composites (MMCs) depends on many aspects of composite microstructure. Fatigue crack growth behavior is particularly dependent on the reinforcement characteristics and matrix microstructure. The goal of this work was to obtain a fundamental understanding of fatigue crack growth behavior in SiC particle-reinforced 2080 Al alloy composites. In situ X-ray synchrotron tomography was performed on two samples at low (R=0.1) and at high (R=0.6) R-ratios. The resulting reconstructed images were used to obtain three-dimensional (3D) rendering of the particles and fatigue crack. Behaviors of the particles and crack, as well as their interaction, were analyzed and quantified. Four-dimensional (4D) visual representations were constructed to aid in the overall understanding of damage evolution. During fatigue crack growth in ductile materials, a plastic zone is created in the region surrounding the crack tip. Knowledge of the plastic zone is important for the understanding of fatigue crack formation as well as subsequent growth behavior. The goal of this work was to quantify the 3D size and shape of the plastic zone in 7075 Al alloys. X-ray synchrotron tomography and Laue microdiffraction were used to non-destructively characterize the volume surrounding a fatigue crack tip. The precise 3D crack profile was segmented from the reconstructed tomography data. Depth-resolved Laue patterns were obtained using

  19. Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations

    Institute of Scientific and Technical Information of China (English)

    Zhonghua Sun

    2011-01-01

    Multislice computed tomography (CT) has been widely used in clinical practice for the diagnosis of cardiovascular disease due to its reduced invasiveness and high spatial and temporal resolution.As a reliable alternative to conventional angiography,multislice CT angiography has been recognized as the method of choice for detecting and diagnosing head and neck vascular disease,abdominal aortic aneurysm,aortic dissection,and pulmonary embolism.In patients with suspected coronary artery disease,although invasive coronary angiography still remains as the gold standard technique,multislice CT angiography demonstrates high diagnostic accuracy; in selected patients,it is considered as the first-line technique.The imaging diagnosis of cardiovascular disease is based on a combination of two-dimensional (2D) and three-dimensional (3D) visualization tools to enhance the diagnostic value.This is facilitated by reconstructed visualizations which provide additional information about the extent of the disease,an accurate assessment of the spatial relationship between normal structures and pathological changes,and pre-operative planning and post-procedure follow-up.The aim of the present article is to present an overview of the diagnostic performance of various 2D and 3D CT visualizations in cardiovascular disease,including multiplanar reformation,maximum intensity projection,volume rendering,and virtual intravascular endoscopy.The recognition of the potential value of these visualizations will assist clinicians in efficiently using the muitislice CT imaging modality for the diagnostic management of patients with cardiovascular disease.

  20. Real-time 3D Fourier-domain optical coherence tomography guided microvascular anastomosis

    Science.gov (United States)

    Huang, Yong; Ibrahim, Zuhaib; Lee, W. P. A.; Brandacher, Gerald; Kang, Jin U.

    2013-03-01

    Vascular and microvascular anastomosis is considered to be the foundation of plastic and reconstructive surgery, hand surgery, transplant surgery, vascular surgery and cardiac surgery. In the last two decades innovative techniques, such as vascular coupling devices, thermo-reversible poloxamers and suture-less cuff have been introduced. Intra-operative surgical guidance using a surgical imaging modality that provides in-depth view and 3D imaging can improve outcome following both conventional and innovative anastomosis techniques. Optical coherence tomography (OCT) is a noninvasive high-resolution (micron level), high-speed, 3D imaging modality that has been adopted widely in biomedical and clinical applications. In this work we performed a proof-of-concept evaluation study of OCT as an assisted intraoperative and post-operative imaging modality for microvascular anastomosis of rodent femoral vessels. The OCT imaging modality provided lateral resolution of 12 μm and 3.0 μm axial resolution in air and 0.27 volume/s imaging speed, which could provide the surgeon with clearly visualized vessel lumen wall and suture needle position relative to the vessel during intraoperative imaging. Graphics processing unit (GPU) accelerated phase-resolved Doppler OCT (PRDOCT) imaging of the surgical site was performed as a post-operative evaluation of the anastomosed vessels and to visualize the blood flow and thrombus formation. This information could help surgeons improve surgical precision in this highly challenging anastomosis of rodent vessels with diameter less than 0.5 mm. Our imaging modality could not only detect accidental suture through the back wall of lumen but also promptly diagnose and predict thrombosis immediately after reperfusion. Hence, real-time OCT can assist in decision-making process intra-operatively and avoid post-operative complications.

  1. Array diagnostics, spatial resolution, and filtering of undesired radiation with the 3D reconstruction algorithm

    DEFF Research Database (Denmark)

    Cappellin, C.; Pivnenko, Sergey; Jørgensen, E.;

    2013-01-01

    This paper focuses on three important features of the 3D reconstruction algorithm of DIATOOL: the identification of array elements improper functioning and failure, the obtainable spatial resolution of the reconstructed fields and currents, and the filtering of undesired radiation and scattering...

  2. The Art of Reconstruction. Documenting the process of 3D modeling: some preliminary results

    NARCIS (Netherlands)

    P.S. Lulof; L. Opgenhaffen; M.H. Sepers

    2013-01-01

    The project `The Art of Reconstruction' explores the usage of digital three-dimensional (3D) reconstructions to support research into historical and archaeological architectural settings. More specifically, the aim is to enhance the research on buildings that are nowadays partly or entirely lost, bu

  3. 3D Tomography of MHD Fluctuations in the H-1NF Heliac

    CERN Document Server

    Haskey, S R; Seiwald, B; Howard, J

    2014-01-01

    A 3D tomographic reconstruction technique which does not rely on a set of radial basis functions is described for inversion of a set of limited-angle high-resolution 2D visible light emission projections (extended in the vertical and toroidal directions) of global MHD eigenmodes in the H-1NF heliac. This paper deals with some of the features and challenges that will arise in the application of tomographic imaging systems to fusion reactors, especially the strong shaping of optimised stellarator/heliotron configurations, and limited access in all types. The fluctuations are represented as a finite sum of Fourier modes characterised by toroidal and poloidal mode numbers having fixed amplitude and phase in a set of nested cylindrical flux volumes in Boozer space. The amplitudes and phases are calculated using iterative tomographic inversion techniques such as ART, SIRT and standard linear least-squares methods. The tomography is applied to synchronous camera images of singly charged carbon impurity ion emission ...

  4. Application of generalized regression neural network on fast 3D reconstruction

    Institute of Scientific and Technical Information of China (English)

    Babakhani Asad; DU Zhi-jiang; SUN Li-ning; Kardan Reza; Mianji A. Fereidoun

    2007-01-01

    In robot-assisted surgery projects,researchers should be able to make fast 3 D reconstruction. Usually 2D images acquired with common diagnostic equipments such as UT, CT and MRI are not enough and complete for an accurate 3D reconstruction. There are some interpolation methods for approximating non value voxels which consume large execution time. A novel algorithm is introduced based on generalized regression neural network (GRNN) which can interpolate unknown voxles fast and reliable. The GRNN interpolation is used to produce new 2D images between each two succeeding ultrasonic images. It is shown that the composition of GRNN with image distance transformation can produce higher quality 3D shapes. The results of this method are compared with other interpolation methods practically. It shows this method can decrease overall time consumption on online 3D reconstruction.

  5. 3D reconstruction of a human heart fascicle using SurfDriver

    Science.gov (United States)

    Rader, Robert J.; Phillips, Steven J.; LaFollette, Paul S., Jr.

    2000-06-01

    The Temple University Medical School has a sequence of over 400 serial sections of adult normal ventricular human heart tissue, cut at 25 micrometer thickness. We used a Zeiss Ultraphot with a 4x planapo objective and a Pixera digital camera to make a series of 45 sequential montages to use in the 3D reconstruction of a fascicle (muscle bundle). We wrote custom software to merge 4 smaller image fields from each section into one composite image. We used SurfDriver software, developed by Scott Lozanoff of the University of Hawaii and David Moody of the University of Alberta, for registration, object boundary identification, and 3D surface reconstruction. We used an Epson Stylus Color 900 printer to get photo-quality prints. We describe the challenge and our solution to the following problems: image acquisition and digitization, image merge, alignment and registration, boundary identification, 3D surface reconstruction, 3D visualization and orientation, snapshot, and photo-quality prints.

  6. A fast 3D reconstruction system with a low-cost camera accessory.

    Science.gov (United States)

    Zhang, Yiwei; Gibson, Graham M; Hay, Rebecca; Bowman, Richard W; Padgett, Miles J; Edgar, Matthew P

    2015-06-09

    Photometric stereo is a three dimensional (3D) imaging technique that uses multiple 2D images, obtained from a fixed camera perspective, with different illumination directions. Compared to other 3D imaging methods such as geometry modeling and 3D-scanning, it comes with a number of advantages, such as having a simple and efficient reconstruction routine. In this work, we describe a low-cost accessory to a commercial digital single-lens reflex (DSLR) camera system allowing fast reconstruction of 3D objects using photometric stereo. The accessory consists of four white LED lights fixed to the lens of a commercial DSLR camera and a USB programmable controller board to sequentially control the illumination. 3D images are derived for different objects with varying geometric complexity and results are presented, showing a typical height error of <3 mm for a 50 mm sized object.

  7. 3D RECONSTRUCTION OF PHALANGEAL AND METACARPAL BONES OF MALE JUDO PLAYERS AND SEDENTARY MEN BY MDCT IMAGES

    Directory of Open Access Journals (Sweden)

    Ibrahim Kalayci

    2008-12-01

    Full Text Available This study has been performed to reveal hand bone peculiarities of elite male judoists by comparing their phalangeal and metacarpal bones with those of sedentary men on the basis of biometric ratio of the bones by means of three-dimensional (3D reconstruction of multidetector computed tomography (MDCT images. For this purpose, the axial images of the right and left hands of 8 elite male judo players (mean age: 22.0 ± 2.9 years, mean weight: 64.0 ± 4.9 kg and 8 sedentary men (mean age: 26.0 ± 2.8 years, mean weight: 69.0 ± 3.6 kg were obtained from MDCT. After semi-automatic segmentation and manual editing, the tracings of bone surfaces were stacked and overlaid to be reconstructed as the 3D images by the 3D program. All biometrical measurements of the reconstructed images of the bones were automatically calculated by this program to analyze statistically. This study showed that the differences between biometric ratios of judoist and sedentary men's hand bones were significant contrary to null hypothesis which was established as there is no difference between biometric hand bone ratios of these men of both groups. Therefore null hypothesis was rejected. Author suggests that intense clutching actions practised in judo sports can most probably lead to some hand bone proliferations. 3D reconstructed results belonging to the judo players and sedentary men help orthopaedists to diagnose pathological formations related to hand bones of judoists and may be used for anatomical education in medicine faculties, respectively. We hope that the results from the biometric and reconstructive techniques carried out in this work will contribute to the present knowledge on judoist and shed light on the future studies on sports medicine related to skeletal structure of other sportsmen

  8. A user-friendly nano-CT image alignment and 3D reconstruction platform based on LabVIEW

    Science.gov (United States)

    Wang, Sheng-Hao; Zhang, Kai; Wang, Zhi-Li; Gao, Kun; Wu, Zhao; Zhu, Pei-Ping; Wu, Zi-Yu

    2015-01-01

    X-ray computed tomography at the nanometer scale (nano-CT) offers a wide range of applications in scientific and industrial areas. Here we describe a reliable, user-friendly, and fast software package based on LabVIEW that may allow us to perform all procedures after the acquisition of raw projection images in order to obtain the inner structure of the investigated sample. A suitable image alignment process to address misalignment problems among image series due to mechanical manufacturing errors, thermal expansion, and other external factors has been considered, together with a novel fast parallel beam 3D reconstruction procedure that was developed ad hoc to perform the tomographic reconstruction. We have obtained remarkably improved reconstruction results at the Beijing Synchrotron Radiation Facility after the image calibration, the fundamental role of this image alignment procedure was confirmed, which minimizes the unwanted blurs and additional streaking artifacts that are always present in reconstructed slices. Moreover, this nano-CT image alignment and its associated 3D reconstruction procedure are fully based on LabVIEW routines, significantly reducing the data post-processing cycle, thus making the activity of the users faster and easier during experimental runs.

  9. 3D High Resolution l1-SPIRiT Reconstruction on Gadgetron based Cloud

    DEFF Research Database (Denmark)

    Xue, Hui; Kelmann, Peter; Inati, Souheil;

    framework to support distributed computing in a cloud environment. This extension is named GT-Plus. A cloud version of 3D l1-SPIRiT was implemented on the GT-Plus framework. We demonstrate that a 3mins reconstruction could be achieved for 1mm3 isotropic resolution neuro scans with significantly improved......Applying non-linear reconstruction to high resolution 3D MRI is challenging because of the lengthy computing time needed for those iterative algorithms. To achieve practical processing duration to enable clinical usage of non-linear reconstruction, we have extended previously published Gadgetron...

  10. Fully 3D PET image reconstruction with a 4D sinogram blurring kernel

    Energy Technology Data Exchange (ETDEWEB)

    Tohme, Michel S.; Qi, Jinyi [California Univ., Davis, CA (United States). Dept. of Biomedical Engineering; Zhou, Jian

    2011-07-01

    Accurately modeling PET system response is essential for high-resolution image reconstruction. Traditionally, sinogram blurring effects are modeled as a 2D blur in each sinogram plane. Such 2D blurring kernel is insufficient for fully 3D PET data, which has four dimensions. In this paper, we implement a fully 3D PET image reconstruction using a 4D sinogram blurring kernel estimated from point source scans and perform phantom experiments to evaluate the improvements in image quality over methods with existing 2D blurring kernels. The results show that the proposed reconstruction method can achieve better spatial resolution and contrast recovery than existing methods. (orig.)

  11. Technology Corner: Virtual Crime Scene Reconstruction: The Basics of 3D Modeling

    Directory of Open Access Journals (Sweden)

    Nick Flor

    2011-12-01

    Full Text Available Digital crime scenes take place in the context of physical crime scenes. Virtual crime scene reconstruction is an activity where investigators create a 3-dimensional (3-D model of an actual crime scene for the purpose of determining the events that lead to the crime. While virtual crime scene reconstruction is currently used for analyzing physical scenes, it can also help investigators visualize and explore ways digital media could have been used to perpetrate a crime. In this technology corner we explore one of the technologies underlying virtual crime scene reconstruction: 3-D modeling. 

  12. 3-D reconstruction of neurons from multichannel confocal laser scanning image series.

    Science.gov (United States)

    Wouterlood, Floris G

    2014-01-01

    A confocal laser scanning microscope (CLSM) collects information from a thin, focal plane and ignores out-of-focus information. Scanning of a specimen, with stepwise axial (Z-) movement of the stage in between each scan, produces Z-series of confocal images of a tissue volume, which then can be used to 3-D reconstruct structures of interest. The operator first configures separate channels (e.g., laser, filters, and detector settings) for each applied fluorochrome and then acquires Z-series of confocal images: one series per channel. Channel signal separation is extremely important. Measures to avoid bleaching are vital. Post-acquisition deconvolution of the image series is often performed to increase resolution before 3-D reconstruction takes place. In the 3-D reconstruction programs described in this unit, reconstructions can be inspected in real time from any viewing angle. By altering viewing angles and by switching channels off and on, the spatial relationships of 3-D-reconstructed structures with respect to structures visualized in other channels can be studied. Since each brand of CLSM, computer program, and 3-D reconstruction package has its own proprietary set of procedures, a general approach is provided in this protocol wherever possible.

  13. 3-D reconstruction of neurons from multichannel confocal laser scanning image series.

    Science.gov (United States)

    Wouterlood, Floris G

    2014-01-01

    A confocal laser scanning microscope (CLSM) collects information from a thin, focal plane and ignores out-of-focus information. Scanning of a specimen, with stepwise axial (Z-) movement of the stage in between each scan, produces Z-series of confocal images of a tissue volume, which then can be used to 3-D reconstruct structures of interest. The operator first configures separate channels (e.g., laser, filters, and detector settings) for each applied fluorochrome and then acquires Z-series of confocal images: one series per channel. Channel signal separation is extremely important. Measures to avoid bleaching are vital. Post-acquisition deconvolution of the image series is often performed to increase resolution before 3-D reconstruction takes place. In the 3-D reconstruction programs described in this unit, reconstructions can be inspected in real time from any viewing angle. By altering viewing angles and by switching channels off and on, the spatial relationships of 3-D-reconstructed structures with respect to structures visualized in other channels can be studied. Since each brand of CLSM, computer program, and 3-D reconstruction package has its own proprietary set of procedures, a general approach is provided in this protocol wherever possible. PMID:24723320

  14. Conceptual detector development and Monte Carlo simulation of a novel 3D breast computed tomography system

    Science.gov (United States)

    Ziegle, Jens; Müller, Bernhard H.; Neumann, Bernd; Hoeschen, Christoph

    2016-03-01

    A new 3D breast computed tomography (CT) system is under development enabling imaging of microcalcifications in a fully uncompressed breast including posterior chest wall tissue. The system setup uses a steered electron beam impinging on small tungsten targets surrounding the breast to emit X-rays. A realization of the corresponding detector concept is presented in this work and it is modeled through Monte Carlo simulations in order to quantify first characteristics of transmission and secondary photons. The modeled system comprises a vertical alignment of linear detectors hold by a case that also hosts the breast. Detectors are separated by gaps to allow the passage of X-rays towards the breast volume. The detectors located directly on the opposite side of the gaps detect incident X-rays. Mechanically moving parts in an imaging system increase the duration of image acquisition and thus can cause motion artifacts. So, a major advantage of the presented system design is the combination of the fixed detectors and the fast steering electron beam which enable a greatly reduced scan time. Thereby potential motion artifacts are reduced so that the visualization of small structures such as microcalcifications is improved. The result of the simulation of a single projection shows high attenuation by parts of the detector electronics causing low count levels at the opposing detectors which would require a flat field correction, but it also shows a secondary to transmission ratio of all counted X-rays of less than 1 percent. Additionally, a single slice with details of various sizes was reconstructed using filtered backprojection. The smallest detail which was still visible in the reconstructed image has a size of 0.2mm.

  15. Evaluation of Model Recognition for Grammar-Based Automatic 3d Building Model Reconstruction

    Science.gov (United States)

    Yu, Qian; Helmholz, Petra; Belton, David

    2016-06-01

    In recent years, 3D city models are in high demand by many public and private organisations, and the steadily growing capacity in both quality and quantity are increasing demand. The quality evaluation of these 3D models is a relevant issue both from the scientific and practical points of view. In this paper, we present a method for the quality evaluation of 3D building models which are reconstructed automatically from terrestrial laser scanning (TLS) data based on an attributed building grammar. The entire evaluation process has been performed in all the three dimensions in terms of completeness and correctness of the reconstruction. Six quality measures are introduced to apply on four datasets of reconstructed building models in order to describe the quality of the automatic reconstruction, and also are assessed on their validity from the evaluation point of view.

  16. A novel 3D template for mandible and maxilla reconstruction: Rapid prototyping using stereolithography

    OpenAIRE

    Samir Kumta; Monica Kumta; Leena Jain; Shrirang Purohit; Rani Ummul

    2015-01-01

    Introduction: Replication of the exact three-dimensional (3D) structure of the maxilla and mandible is now a priority whilst attempting reconstruction of these bones to attain a complete functional and aesthetic rehabilitation. We hereby present the process of rapid prototyping using stereolithography to produce templates for modelling bone grafts and implants for maxilla/mandible reconstructions, its applications in tumour/trauma, and outcomes for primary and secondary reconstruction. Materi...

  17. GOTHIC CHURCHES IN PARIS ST GERVAIS ET ST PROTAIS IMAGE MATCHING 3D RECONSTRUCTION TO UNDERSTAND THE VAULTS SYSTEM GEOMETRY

    Directory of Open Access Journals (Sweden)

    M. Capone

    2015-02-01

    benefits and the troubles. From a methodological point of view this is our workflow: - theoretical study about geometrical configuration of rib vault systems; - 3D model based on theoretical hypothesis about geometric definition of the vaults' form; - 3D model based on image matching 3D reconstruction methods; - comparison between 3D theoretical model and 3D model based on image matching;

  18. AX-PET A novel PET detector concept with full 3D reconstruction

    CERN Document Server

    Braem, A; Séguinot, J; Dissertori, G; Djambazov, L; Lustermann, W; Nessi-Tedaldi, F; Pauss, F; Schinzel, D; Solevi, P; Lacasta, C; Oliver, J F; Rafecas, M; De Leo, R; Nappi, E; Vilardi, I; Chesi, E; Cochran, E; Honscheid, K; Kagan, H; Rudge, A; Smith, S; Weilhammer, P; Johnson, I; Renker, D; Clinthorne, N; Huh, S; Bolle, E; Stapnes, S; Meddi, F

    2009-01-01

    We describe the concept and first experimental tests of a novel 3D axial Positron Emission Tomography (PET) geometry. It allows for a new way of measuring the interaction point in the detector with very high precision. It is based on a matrix of long Lutetium-Yttrium OxyorthoSilicate (LYSO) crystals oriented in the axial direction, each coupled to one Geiger Mode Avalanche Photodiode (G-APD) array. To derive the axial coordinate, Wave Length Shifter (WLS) strips are mounted orthogonally and interleaved between the crystals. The light from the WLS strips is read by custom-made G-APDs. The weighted mean of the signals in the WLS strips has proven to give very precise axial resolution. The achievable resolution along the three axes is mainly driven by the dimensions of the LYSO crystals and WLS strips. This concept is inherently free of parallax errors. Furthermore, it will allow identification of Compton interactions in the detector and for reconstruction of a fraction of them, which is expected to enhance imag...

  19. New Algorithm for 3D Facial Model Reconstruction and Its Application in Virtual Reality

    Institute of Scientific and Technical Information of China (English)

    Rong-Hua Liang; Zhi-Geng Pan; Chun Chen

    2004-01-01

    3D human face model reconstruction is essential to the generation of facial animations that is widely used in the field of virtual reality(VR).The main issues of 3D facial model reconstruction based on images by vision technologies are in twofold: one is to select and match the corresponding features of face from two images with minimal interaction and the other is to generate the realistic-looking human face model.In this paper,a new algorithm for realistic-looking face reconstruction is presented based on stereo vision.Firstly,a pattern is printed and attached to a planar surface for camera calibration,and corners generation and corners matching between two images are performed by integrating modified image pyramid Lucas-Kanade(PLK)algorithm and local adjustment algorithm,and then 3D coordinates of corners are obtained by 3D reconstruction.Individual face model is generated by the deformation of general 3D model and interpolation of the features.Finally,realisticlooking human face model is obtained after texture mapping and eyes modeling.In addition,some application examples in the field of VR are given.Experimental result shows that the proposed algorithm is robust and the 3D model is photo-realistic.

  20. Impact of Level of Details in the 3d Reconstruction of Trees for Microclimate Modeling

    Science.gov (United States)

    Bournez, E.; Landes, T.; Saudreau, M.; Kastendeuch, P.; Najjar, G.

    2016-06-01

    In the 21st century, urban areas undergo specific climatic conditions like urban heat islands which frequency and intensity increase over the years. Towards the understanding and the monitoring of these conditions, vegetation effects on urban climate are studied. It appears that a natural phenomenon, the evapotranspiration of trees, generates a cooling effect in urban environment. In this work, a 3D microclimate model is used to quantify the evapotranspiration of trees in relation with their architecture, their physiology and the climate. These three characteristics are determined with field measurements and data processing. Based on point clouds acquired with terrestrial laser scanner (TLS), the 3D reconstruction of the tree wood architecture is performed. Then the 3D reconstruction of leaves is carried out from the 3D skeleton of vegetative shoots and allometric statistics. With the aim of extending the simulation on several trees simultaneously, it is necessary to apply the 3D reconstruction process on each tree individually. However, as well for the acquisition as for the processing, the 3D reconstruction approach is time consuming. Mobile laser scanners could provide point clouds in a faster way than static TLS, but this implies a lower point density. Also the processing time could be shortened, but under the assumption that a coarser 3D model is sufficient for the simulation. In this context, the criterion of level of details and accuracy of the tree 3D reconstructed model must be studied. In this paper first tests to assess their impact on the determination of the evapotranspiration are presented.

  1. Practical limitations of cone-beam computed tomography in 3D cephalometry

    NARCIS (Netherlands)

    Damstra, Janalt; Fourie, Zacharias; Ren, Yijin

    2011-01-01

    3D cone beam computed tomography (CBCT) images offer a unique and new appreciation of the anatomical structures and underlying anomalies not possible with conventional radiographs. However, in almost all aspects of CBCT imaging, from utilization to application, inherent limitations and pitfalls exis

  2. Capacitance Measurement with a Sigma Delta Converter for 3D Electrical Capacitance Tomography

    Science.gov (United States)

    Nurge, Mark

    2005-01-01

    This paper will explore suitability of a newly available capacitance to digital converter for use in a 3D Electrical Capacitance Tomography system. A switch design is presented along with circuitry needed to extend the range of the capacitance to digital converter. Results are then discussed for a 15+ hour drift and noise test.

  3. A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carlier, Stéphane, E-mail: sgcarlier@hotmail.com [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Didday, Rich [INDEC Medical Systems Inc., Santa Clara, CA (United States); Slots, Tristan [Pie Medical Imaging BV, Maastricht (Netherlands); Kayaert, Peter; Sonck, Jeroen [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium); El-Mourad, Mike; Preumont, Nicolas [Department of Cardiology, Erasme University Hospital, Université Libre de Bruxelles (ULB), Brussels (Belgium); Schoors, Dany; Van Camp, Guy [Department of Cardiology, Universitair Ziekenhuis - UZ Brussel, Brussels (Belgium)

    2014-06-15

    We present a new clinically practical method for online co-registration of 3D quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) or optical coherence tomography (OCT). The workflow is based on two modified commercially available software packages. Reconstruction steps are explained and compared to previously available methods. The feasibility for different clinical scenarios is illustrated. The co-registration appears accurate, robust and induced a minimal delay on the normal cath lab activities. This new method is based on the 3D angiographic reconstruction of the catheter path and does not require operator’s identification of landmarks to establish the image synchronization.

  4. Digital 3D Facial Reconstruction Based on Computed Tomography

    OpenAIRE

    Andersson, Björn; Valfridsson, Martin

    2005-01-01

    Despite the introduction of DNA-analysis for identification of human remains (1997-2000) several cases exist where the deceased remain unidentified. Approximately ten percent of unknown deceased persons can not be identified by dental status or other present methods. During the year 2003 alone, seven individuals, in Sweden, remain unidentified. Increase in travel in Europe will lead to more discoveries of foreign human remains in Sweden. In these cases, dental and medical records are often u...

  5. Electrical Impedance Tomography: 3D Reconstructions using Scattering Transforms

    DEFF Research Database (Denmark)

    Delbary, Fabrice; Hansen, Per Christian; Knudsen, Kim

    2012-01-01

    is in principle direct and addresses the full non-linear problem immediately. In this paper a new simplication of the algorithm is suggested. The method is based on solving a boundary integral equation for the complex geometrical optics solutions, and the method is implemented numerically using a Nystrom method...

  6. Tomography Reconstruction with Noisy Projection Data

    Institute of Scientific and Technical Information of China (English)

    LI Xide

    2000-01-01

    Computerized tomography (CT) based on the convolution back projection method has been regarded as an important reconstruction method, but it is not suitable to noisy conditions. In this paper, techniques of filtering, resampling and frequency shifting have been introduced to enhance the quality of CT reconstruction and improved results have been obtained.

  7. 3D reconstruction and digitalization of an archeological site, Itanos, Crete

    Directory of Open Access Journals (Sweden)

    Rudy Ercek

    2010-04-01

    Full Text Available The city of Itanos is situated in the North-East of Crete. Between 1994 and 2005, the French School of Archaeology at Athens (Efa and the Center for Mediterranean Studies in Rethymnon carried out excavation campaigns during which a necropolis and an Archaic building have been explored by a team of the CReA. A very close collaboration between archeologists, engineers and computer graphic designers allowed the 3D reconstruction of these remains. The archeologist was able to directly verify his hypotheses during the reconstruction process. In summer 2007 and 2008, a 3D digitalization of Itanos was made in order to insert the 3D reconstructions into the actual landscape.

  8. Reconstruction of Temperature Field in 3-D, Absorbing, Emitting,and Anisotropically Scattering Medium

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jing-de; LIU Ni; ZHONG Ke

    2006-01-01

    The soft measurement technology of flame temperature field is an efficient method to learn the combustion status in furnace. Generally, it reconstructs the temperature field in furnace through the image of flame, which is a process to solve radiative inverse problem. In this paper, the flame of pulverized coal is considered as 3-D, absorbing, emitting,and anisotropically scattering non-gray medium. Through the study on inverse problem of radiative heat transfer, the temperature field in this kind of medium has been reconstructed. The mechanism of 3-D radiative heat transfer in a rectangular media, which is 2 m × 3 m × 5 m and full of CO2, N2 and carbon particles, is studied with Monte Carlo method. The 3-D temperature field in this rectangular space is reconstructed and the influence of particles density profile is discussed.

  9. Reliable Gait Recognition Using 3D Reconstructions and Random Forests - An Anthropometric Approach.

    Science.gov (United States)

    Sandau, Martin; Heimbürger, Rikke V; Jensen, Karl E; Moeslund, Thomas B; Aanaes, Henrik; Alkjaer, Tine; Simonsen, Erik B

    2016-05-01

    Photogrammetric measurements of bodily dimensions and analysis of gait patterns in CCTV are important tools in forensic investigations but accurate extraction of the measurements are challenging. This study tested whether manual annotation of the joint centers on 3D reconstructions could provide reliable recognition. Sixteen participants performed normal walking where 3D reconstructions were obtained continually. Segment lengths and kinematics from the extremities were manually extracted by eight expert observers. The results showed that all the participants were recognized, assuming the same expert annotated the data. Recognition based on data annotated by different experts was less reliable achieving 72.6% correct recognitions as some parameters were heavily affected by interobserver variability. This study verified that 3D reconstructions are feasible for forensic gait analysis as an improved alternative to conventional CCTV. However, further studies are needed to account for the use of different clothing, field conditions, etc.

  10. Real-Time Camera Tracking and 3D Reconstruction Using Signed Distance Functions

    OpenAIRE

    Bylow, Erik; Sturm, Jürgen; Kerl, Christian; Kahl, Fredrik; Cremers, Daniel

    2013-01-01

    The ability to quickly acquire 3D models is an essential capability needed in many disciplines including robotics, computer vision, geodesy, and architecture. In this paper we present a novel method for real-time camera tracking and 3D reconstruction of static indoor environments using an RGB-D sensor. We show that by representing the geometry with a signed distance function (SDF), the camera pose can be efficiently estimated by directly minimizing the error of the depth images on the SDF....

  11. Influence of camera calibration conditions on the accuracy of 3D reconstruction.

    Science.gov (United States)

    Poulin-Girard, Anne-Sophie; Thibault, Simon; Laurendeau, Denis

    2016-02-01

    For stereoscopic systems designed for metrology applications, the accuracy of camera calibration dictates the precision of the 3D reconstruction. In this paper, the impact of various calibration conditions on the reconstruction quality is studied using a virtual camera calibration technique and the design file of a commercially available lens. This technique enables the study of the statistical behavior of the reconstruction task in selected calibration conditions. The data show that the mean reprojection error should not always be used to evaluate the performance of the calibration process and that a low quality of feature detection does not always lead to a high mean reconstruction error.

  12. Sampling of finite elements for sparse recovery in large scale 3D electrical impedance tomography

    International Nuclear Information System (INIS)

    This study proposes a method to improve performance of sparse recovery inverse solvers in 3D electrical impedance tomography (3D EIT), especially when the volume under study contains small-sized inclusions, e.g. 3D imaging of breast tumours. Initially, a quadratic regularized inverse solver is applied in a fast manner with a stopping threshold much greater than the optimum. Based on assuming a fixed level of sparsity for the conductivity field, finite elements are then sampled via applying a compressive sensing (CS) algorithm to the rough blurred estimation previously made by the quadratic solver. Finally, a sparse inverse solver is applied solely to the sampled finite elements, with the solution to the CS as its initial guess. The results show the great potential of the proposed CS-based sparse recovery in improving accuracy of sparse solution to the large-size 3D EIT. (paper)

  13. 3D Reconstruction and Restoration Monitoring of Sculptural Artworks by a Multi-Sensor Framework

    Directory of Open Access Journals (Sweden)

    Sandro Barone

    2012-12-01

    Full Text Available Nowadays, optical sensors are used to digitize sculptural artworks by exploiting various contactless technologies. Cultural Heritage applications may concern 3D reconstructions of sculptural shapes distinguished by small details distributed over large surfaces. These applications require robust multi-view procedures based on aligning several high resolution 3D measurements. In this paper, the integration of a 3D structured light scanner and a stereo photogrammetric sensor is proposed with the aim of reliably reconstructing large free form artworks. The structured light scanner provides high resolution range maps captured from different views. The stereo photogrammetric sensor measures the spatial location of each view by tracking a marker frame integral to the optical scanner. This procedure allows the computation of the rotation-translation matrix to transpose the range maps from local view coordinate systems to a unique global reference system defined by the stereo photogrammetric sensor. The artwork reconstructions can be further augmented by referring metadata related to restoration processes. In this paper, a methodology has been developed to map metadata to 3D models by capturing spatial references using a passive stereo-photogrammetric sensor. The multi-sensor framework has been experienced through the 3D reconstruction of a Statue of Hope located at the English Cemetery in Florence. This sculptural artwork has been a severe test due to the non-cooperative environment and the complex shape features distributed over a large surface.

  14. GPU-Based 3D Cone-Beam CT Image Reconstruction for Large Data Volume

    Directory of Open Access Journals (Sweden)

    Xing Zhao

    2009-01-01

    Full Text Available Currently, 3D cone-beam CT image reconstruction speed is still a severe limitation for clinical application. The computational power of modern graphics processing units (GPUs has been harnessed to provide impressive acceleration of 3D volume image reconstruction. For extra large data volume exceeding the physical graphic memory of GPU, a straightforward compromise is to divide data volume into blocks. Different from the conventional Octree partition method, a new partition scheme is proposed in this paper. This method divides both projection data and reconstructed image volume into subsets according to geometric symmetries in circular cone-beam projection layout, and a fast reconstruction for large data volume can be implemented by packing the subsets of projection data into the RGBA channels of GPU, performing the reconstruction chunk by chunk and combining the individual results in the end. The method is evaluated by reconstructing 3D images from computer-simulation data and real micro-CT data. Our results indicate that the GPU implementation can maintain original precision and speed up the reconstruction process by 110–120 times for circular cone-beam scan, as compared to traditional CPU implementation.

  15. SU-E-J-128: 3D Surface Reconstruction of a Patient Using Epipolar Geometry

    Energy Technology Data Exchange (ETDEWEB)

    Kotoku, J; Nakabayashi, S; Kumagai, S; Ishibashi, T; Kobayashi, T [Teikyo University, Itabashi-ku, Tokyo (Japan); Haga, A; Saotome, N [University of Tokyo Hospital, Bunkyo-ku, Tokyo (Japan); Arai, N [Teikyo University Hospital, Itabashi-ku, Tokyo (Japan)

    2014-06-01

    Purpose: To obtain a 3D surface data of a patient in a non-invasive way can substantially reduce the effort for the registration of patient in radiation therapy. To achieve this goal, we introduced the multiple view stereo technique, which is known to be used in a 'photo tourism' on the internet. Methods: 70 Images were taken with a digital single-lens reflex camera from different angles and positions. The camera positions and angles were inferred later in the reconstruction step. A sparse 3D reconstruction model was locating by SIFT features, which is robust for rotation and shift variance, in each image. We then found a set of correspondences between pairs of images by computing the fundamental matrix using the eight-point algorithm with RANSAC. After the pair matching, we optimized the parameter including camera positions to minimize the reprojection error by use of bundle adjustment technique (non-linear optimization). As a final step, we performed dense reconstruction and associate a color with each point using the library of PMVS. Results: Surface data were reconstructed well by visual inspection. The human skin is reconstructed well, althogh the reconstruction was time-consuming for direct use in daily clinical practice. Conclusion: 3D reconstruction using multi view stereo geometry is a promising tool for reducing the effort of patient setup. This work was supported by JSPS KAKENHI(25861128)

  16. MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G [University of Wisconsin, Madison, WI (United States); Pan, X [University Chicago, Chicago, IL (United States); Stayman, J [Johns Hopkins University, Baltimore, MD (United States); Samei, E [Duke University Medical Center, Durham, NC (United States)

    2014-06-15

    Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical

  17. Reconstruction of 3D models of cast sculptures using close-range photogrammetry

    OpenAIRE

    Ž. Santoši; Šokac, M.; Korolija-Crkvenjakov, D.; B. Kosec; M. Soković; I. Budak

    2015-01-01

    This paper presents the possibilities of application of close-range photogrammetry, based on the Structure-from- Motion (SfM) approach, in 3D model’s reconstruction of bronze cast sculptures. Special attention was dedicated to the analysis of image processing strategy, and its impact on the 3D model reconstruction quality. For the purpose of analysis a bust of Nikola Tesla, placed in front of the Faculty of Technical Sciences University of Novi Sad was used. Experimental results indicate that...

  18. Holographic and weak-phase projection system for 3D shape reconstruction using temporal phase unwrapping

    Science.gov (United States)

    González, C. A.; Dávila, A.; Garnica, G.

    2007-09-01

    Two projection systems that use an LCoS phase modulator are proposed for 3D shape reconstruction. The LCoS is used as an holographic system or as a weak phase projector, both configurations project a set of fringe patterns that are processed by the technique known as temporal phase unwrapping. To minimize the influence of camera sampling, and the speckle noise in the projected fringes, an speckle noise reduction technique is applied to the speckle patterns generated by the holographic optical system. Experiments with 3D shape reconstruction of ophthalmic mold and other testing specimens show the viability of the proposed techniques.

  19. Reliable Gait Recognition Using 3D Reconstructions and Random Forests - An Anthropometric Approach

    DEFF Research Database (Denmark)

    Sandau, Martin; Heimbürger, Rikke V.; Jensen, Karl E.;

    2016-01-01

    Photogrammetric measurements of bodily dimensions and analysis of gait patterns in CCTV are important tools in forensic investigations but accurate extraction of the measurements are challenging. This study tested whether manual annotation of the joint centers on 3D reconstructions could provide...... expert annotated the data. Recognition based on data annotated by different experts was less reliable achieving 72.6% correct recognitions as some parameters were heavily affected by interobserver variability. This study verified that 3D reconstructions are feasible for forensic gait analysis...

  20. CUDA based Level Set Method for 3D Reconstruction of Fishes from Large Acoustic Data

    DEFF Research Database (Denmark)

    Sharma, Ojaswa; Anton, François

    2009-01-01

    Acoustic images present views of underwater dynamics, even in high depths. With multi-beam echo sounders (SONARs), it is possible to capture series of 2D high resolution acoustic images. 3D reconstruction of the water column and subsequent estimation of fish abundance and fish species identificat......Acoustic images present views of underwater dynamics, even in high depths. With multi-beam echo sounders (SONARs), it is possible to capture series of 2D high resolution acoustic images. 3D reconstruction of the water column and subsequent estimation of fish abundance and fish species...

  1. 3-D reconstruction of coastal bathymetry from AIRSAR/POLSAR data

    Institute of Scientific and Technical Information of China (English)

    Maged MARGHANY; Mazlan HASHIM; Arthur P. CRACKNELL

    2009-01-01

    This paper introduces a new method for reconstructing three-dimensional (3D) coastal bathymetry changes from Airborne AIRSAR/POLSAR synthetic aperture data. The new method is based on integration between fuzzy B-spline and Volterra algorithm. Volterra algorithm is used to simulate the ocean surface current from AIRSAR/POLSAR data. Then, the ocean surface current information used as input for continuity equation to estimate the water depths from AIRSAR/POLSAR data. This study shows that 3D ocean bathymetry can be reconstructed from AIRSAR/POLSAR data with root mean square error of ±0.03 m.

  2. Etruscanning 3D project. The 3D reconstruction of the Regolini Galassi Tomb as a research tool and a new approach in storytelling

    NARCIS (Netherlands)

    W. Hupperetz; R. Carlani; D. Pletinckx; E. Pietroni

    2012-01-01

    In the "Etruscanning3D" european project framework, the virtual reconstruction of the Regolini Galassi tomb, in Cerveteri, has been realized, in order to recontextualize its precious funerary goods, today preserved in the vatican Museums, in their ancient space, digitally represented in 3D. The reco

  3. Grammar-based Automatic 3D Model Reconstruction from Terrestrial Laser Scanning Data

    Science.gov (United States)

    Yu, Q.; Helmholz, P.; Belton, D.; West, G.

    2014-04-01

    The automatic reconstruction of 3D buildings has been an important research topic during the last years. In this paper, a novel method is proposed to automatically reconstruct the 3D building models from segmented data based on pre-defined formal grammar and rules. Such segmented data can be extracted e.g. from terrestrial or mobile laser scanning devices. Two steps are considered in detail. The first step is to transform the segmented data into 3D shapes, for instance using the DXF (Drawing Exchange Format) format which is a CAD data file format used for data interchange between AutoCAD and other program. Second, we develop a formal grammar to describe the building model structure and integrate the pre-defined grammars into the reconstruction process. Depending on the different segmented data, the selected grammar and rules are applied to drive the reconstruction process in an automatic manner. Compared with other existing approaches, our proposed method allows the model reconstruction directly from 3D shapes and takes the whole building into account.

  4. Investigation of gas-solids flow in a circulating fluidized bed using 3D electrical capacitance tomography

    Science.gov (United States)

    Mao, Mingxu; Ye, Jiamin; Wang, Haigang; Yang, Wuqiang

    2016-09-01

    The hydrodynamics of gas-solids flow in the bottom of a circulating fluidized bed (CFB) are complicated. Three-dimensional (3D) electrical capacitance tomography (ECT) has been used to investigate the hydrodynamics in risers of different shapes. Four different ECT sensors with 12 electrodes each are designed according to the dimension of risers, including two circular ECT sensors, a square ECT sensor and a rectangular ECT sensor. The electrodes are evenly arranged in three planes to obtain capacitance in different heights and to reconstruct the 3D images by linear back projection (LBP) algorithm. Experiments were carried out on the four risers using sands as the solids material. The capacitance and differential pressure are measured under the gas superficial velocity from 0.6 m s-1 to 3.0 m s-1 with a step of 0.2 m s-1. The flow regime is investigated according to the solids concentration and differential pressure. The dynamic property of bubbling flows is analyzed theoretically and the performance of the 3D ECT sensors is evaluated. The experimental results show that 3D ECT can be used in the CFB with different risers to predict the hydrodynamics of gas-solids bubbling flows.

  5. A new cone-beam computed tomography system for dental applications with innovative 3D software

    Energy Technology Data Exchange (ETDEWEB)

    Pasini, Alessandro; Bianconi, D.; Rossi, A. [University of Bologna, Department of Physics, Bologna (Italy); NECTAR Imaging srl Imola (Italy); Casali, F. [University of Bologna, Department of Physics, Bologna (Italy); Bontempi, M. [CEFLA Dental Group Imola (Italy)

    2007-02-15

    Objective Cone beam computed tomography (CBCT) is an important image technique for oral surgery (dentoalveolar surgery and dental implantology) and maxillofacial applications. This technique requires compact sized scanners with a relatively low radiation dosage, which makes them suitable for imaging of the craniofacial region. This article aims to present the concept and the preliminary findings obtained with the prototype of a new CBCT scanner with dedicated 3D software, specifically designed for dental imaging. Methods The prototype implements an X-ray tube with a nominal focal spot of 0.5 mm operating at 70-100 kVp and 1-4 mA. The detector is a 6 in. image intensifier coupled with a digital CCD camera. Dosimetry was performed on a RANDO anthropomorphic phantom using Beryllium Oxide thermo-luminescent dosimeters positioned in the phantom in the following site: eyes, thyroid, skin (lips, cheeks, back of the neck), brain, mandible, maxilla and parotid glands. Doses were measured using four configurations, changing the field-of-view (4'' and 6'') and acquisition time (10 and 20 s) of the CBCT. Acquisitions were performed with different parameters regarding the x-ray tube, pixel size and acquisition geometries to evaluate image quality in relation to modulation transfer function (MTF), noise and geometric accuracy. Results The prototype was able to acquire a complete maxillofacial scan in 10-15 s. The CT reconstruction algorithm delivered images that were judged to have high quality, allowing for precise volume rendering. The radiation dose was determined to be 1-1.5 times that of the dose applied during conventional dental panoramic studies. Conclusion Preliminary studies using the CBCT prototype indicate that this device provides images with acceptable diagnostic content at a relatively low radiation dosage, if compared to systems currently available on the market. (orig.)

  6. A model-based reconstruction method for 3-D rotational coronary angiography

    Science.gov (United States)

    Xie, Lizhe; Hu, Yining; Nunes, Jean-Claude; Bellanger, Jean-Jacques; Bedossa, Marc; Luo, Limin; Toumoulin, Christine

    2010-01-01

    This paper presents a model-based reconstruction method of the coronary tree from a few number of projections in rotational angiography imaging. The reconstruction relies on projections acquired at a same cardiac phase and an energy function minimization that aims to lead the deformation of the 3D model to fit projection data whereas preserving coherence both in time and space. Some preliminary results are provided on simulated rotational angiograms. PMID:21096600

  7. Demonstration of digital hologram recording and 3D-scenes reconstruction in real-time

    Science.gov (United States)

    Cheremkhin, Pavel A.; Evtikhiev, Nikolay N.; Krasnov, Vitaly V.; Kulakov, Mikhail N.; Kurbatova, Ekaterina A.; Molodtsov, Dmitriy Y.; Rodin, Vladislav G.

    2016-04-01

    Digital holography is technique that allows to reconstruct information about 2D-objects and 3D-scenes. This is achieved by registration of interference pattern formed by two beams: object and reference ones. Pattern registered by the digital camera is processed. This allows to obtain amplitude and phase of the object beam. Reconstruction of shape of the 2D objects and 3D-scenes can be obtained numerically (using computer) and optically (using spatial light modulators - SLMs). In this work camera Megaplus II ES11000 was used for digital holograms recording. The camera has 4008 × 2672 pixels with sizes of 9 μm × 9 μm. For hologram recording, 50 mW frequency-doubled Nd:YAG laser with wavelength 532 nm was used. Liquid crystal on silicon SLM HoloEye PLUTO VIS was used for optical reconstruction of digital holograms. SLM has 1920 × 1080 pixels with sizes of 8 μm × 8 μm. At objects reconstruction 10 mW He-Ne laser with wavelength 632.8 nm was used. Setups for digital holograms recording and their optical reconstruction with the SLM were combined as follows. MegaPlus Central Control Software allows to display registered frames by the camera with a little delay on the computer monitor. The SLM can work as additional monitor. In result displayed frames can be shown on the SLM display in near real-time. Thus recording and reconstruction of the 3D-scenes was obtained in real-time. Preliminary, resolution of displayed frames was chosen equaled to the SLM one. Quantity of the pixels was limited by the SLM resolution. Frame rate was limited by the camera one. This holographic video setup was applied without additional program implementations that would increase time delays between hologram recording and object reconstruction. The setup was demonstrated for reconstruction of 3D-scenes.

  8. 3D reconstruction of complex geological bodies: Examples from the Alps

    Science.gov (United States)

    Zanchi, Andrea; Francesca, Salvi; Stefano, Zanchetta; Simone, Sterlacchini; Graziano, Guerra

    2009-01-01

    Cartographic geological and structural data collected in the field and managed by Geographic Information Systems (GIS) technology can be used for 3D reconstruction of complex geological bodies. Using a link between GIS tools and gOcad, stratigraphic and tectonic surfaces can be reconstructed taking into account any geometrical constraint derived from field observations. Complex surfaces can be reconstructed using large data sets analysed by suitable geometrical techniques. Three main typologies of geometric features and related attributes are exported from a GIS-geodatabase: (1) topographic data as points from a digital elevation model; (2) stratigraphic and tectonic boundaries, and linear features as 2D polylines; (3) structural data as points. After having imported the available information into gOcad, the following steps should be performed: (1) construction of the topographic surface by interpolation of points; (2) 3D mapping of the linear geological boundaries and linear features by vertical projection on the reconstructed topographic surface; (3) definition of geometrical constraints from planar and linear outcrop data; (4) construction of a network of cross-sections based on field observations and geometrical constraints; (5) creation of 3D surfaces, closed volumes and grids from the constructed objects. Three examples of the reconstruction of complex geological bodies from the Italian Alps are presented here. The methodology demonstrates that although only outcrop data were available, 3D modelling has allows the checking of the geometrical consistency of the interpretative 2D sections and of the field geology, through a 3D visualisation of geometrical models. Application of a 3D geometrical model to the case studies can be very useful in geomechanical modelling for slope-stability or resource evaluation.

  9. 3D Reconstruction from X-ray Fluoroscopy for Clinical Veterinary Medicine using Differential Volume Rendering

    Science.gov (United States)

    Khongsomboon, Khamphong; Hamamoto, Kazuhiko; Kondo, Shozo

    3D reconstruction from ordinary X-ray equipment which is not CT or MRI is required in clinical veterinary medicine. Authors have already proposed a 3D reconstruction technique from X-ray photograph to present bone structure. Although the reconstruction is useful for veterinary medicine, the thechnique has two problems. One is about exposure of X-ray and the other is about data acquisition process. An x-ray equipment which is not special one but can solve the problems is X-ray fluoroscopy. Therefore, in this paper, we propose a method for 3D-reconstruction from X-ray fluoroscopy for clinical veterinary medicine. Fluoroscopy is usually used to observe a movement of organ or to identify a position of organ for surgery by weak X-ray intensity. Since fluoroscopy can output a observed result as movie, the previous two problems which are caused by use of X-ray photograph can be solved. However, a new problem arises due to weak X-ray intensity. Although fluoroscopy can present information of not only bone structure but soft tissues, the contrast is very low and it is very difficult to recognize some soft tissues. It is very useful to be able to observe not only bone structure but soft tissues clearly by ordinary X-ray equipment in the field of clinical veterinary medicine. To solve this problem, this paper proposes a new method to determine opacity in volume rendering process. The opacity is determined according to 3D differential coefficient of 3D reconstruction. This differential volume rendering can present a 3D structure image of multiple organs volumetrically and clearly for clinical veterinary medicine. This paper shows results of simulation and experimental investigation of small dog and evaluation by veterinarians.

  10. The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers

    International Nuclear Information System (INIS)

    Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months postoperatively in all patients. The images were generated on a computer workstation using the shaded surface display (SSD) software with threshold values ranging 425 to 630 HU, and a more closed window for the imaging of titanium mesh/bone interface in the post surgical follow-up. It was obtained an excellent complete spatial depiction of maxillo facial region both before and after surgery, with no artefacts so important as to affect the 3D reconstruction process and the image quality. Together with the head-neck surgical team it could be worked for preoperative planning through CT scans by different 3D points of view. The 3D reconstructed follow-up scans showed good filling of the defect in the area where the titanium mesh had been used. Then efficacious bone modelling and good biocompatibility of the alloplastic material were seen in all patients, with no inflammatory reactions. Titanium is a well-known material, which is widely used for cranioplasty. It is a radiolucent, non

  11. Sample based 3D face reconstruction from a single frontal image by adaptive locally linear embedding

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jian; ZHUANG Yue-ting

    2007-01-01

    In this paper, we propose a highly automatic approach for 3D photorealistic face reconstruction from a single frontal image. The key point of our work is the implementation of adaptive manifold learning approach. Beforehand, an active appearance model (AAM) is trained for automatic feature extraction and adaptive locally linear embedding (ALLE) algorithm is utilized to reduce the dimensionality of the 3D database. Then, given an input frontal face image, the corresponding weights between 3D samples and the image are synthesized adaptively according to the AAM selected facial features. Finally, geometry reconstruction is achieved by linear weighted combination of adaptively selected samples. Radial basis function (RBF) is adopted to map facial texture from the frontal image to the reconstructed face geometry. The texture of invisible regions between the face and the ears is interpolated by sampling from the frontal image. This approach has several advantages: (1) Only a single frontal face image is needed for highly automatic face reconstruction; (2) Compared with former works, our reconstruction approach provides higher accuracy; (3) Constraint based RBF texture mapping provides natural appearance for reconstructed face.

  12. Error Evaluation in a Stereovision-Based 3D Reconstruction System

    Directory of Open Access Journals (Sweden)

    Kohler Sophie

    2010-01-01

    Full Text Available The work presented in this paper deals with the performance analysis of the whole 3D reconstruction process of imaged objects, specifically of the set of geometric primitives describing their outline and extracted from a pair of images knowing their associated camera models. The proposed analysis focuses on error estimation for the edge detection process, the starting step for the whole reconstruction procedure. The fitting parameters describing the geometric features composing the workpiece to be evaluated are used as quality measures to determine error bounds and finally to estimate the edge detection errors. These error estimates are then propagated up to the final 3D reconstruction step. The suggested error analysis procedure for stereovision-based reconstruction tasks further allows evaluating the quality of the 3D reconstruction. The resulting final error estimates enable lastly to state if the reconstruction results fulfill a priori defined criteria, for example, fulfill dimensional constraints including tolerance information, for vision-based quality control applications for example.

  13. The point-source method for 3D reconstructions for the Helmholtz and Maxwell equations

    Science.gov (United States)

    Ben Hassen, M. F.; Erhard, K.; Potthast, R.

    2006-02-01

    We use the point-source method (PSM) to reconstruct a scattered field from its associated far field pattern. The reconstruction scheme is described and numerical results are presented for three-dimensional acoustic and electromagnetic scattering problems. We give new proofs of the algorithms, based on the Green and Stratton-Chu formulae, which are more general than with the former use of the reciprocity relation. This allows us to handle the case of limited aperture data and arbitrary incident fields. Both for 3D acoustics and electromagnetics, numerical reconstructions of the field for different settings and with noisy data are shown. For shape reconstruction in acoustics, we develop an appropriate strategy to identify areas with good reconstruction quality and combine different such regions into one joint function. Then, we show how shapes of unknown sound-soft scatterers are found as level curves of the total reconstructed field.

  14. Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography

    CERN Document Server

    wang, Kun; Oraevsky, Alexander A; Anastasio, Mark A

    2012-01-01

    Iterative image reconstruction algorithms for optoacoustic tomography (OAT), also known as photoacoustic tomography, have the ability to improve image quality over analytic algorithms due to their ability to incorporate accurate models of the imaging physics, instrument response, and measurement noise. However, to date, there have been few reported attempts to employ advanced iterative image reconstruction algorithms for improving image quality in three-dimensional (3D) OAT. In this work, we implement and investigate two iterative image reconstruction methods for use with a 3D OAT small animal imager: namely, a penalized least-squares (PLS) method employing a quadratic smoothness penalty and a PLS method employing a total variation norm penalty. The reconstruction algorithms employ accurate models of the ultrasonic transducer impulse responses. Experimental data sets are employed to compare the performances of the iterative reconstruction algorithms to that of a 3D filtered backprojection (FBP) algorithm. By ...

  15. A method for 3D-reconstruction of a muscle thick filament using the tilt series images of a single filament electron tomogram.

    Science.gov (United States)

    Márquez, G; Pinto, A; Alamo, L; Baumann, B; Ye, F; Winkler, H; Taylor, K; Padrón, R

    2014-05-01

    Myosin interacting-heads (MIH) motifs are visualized in 3D-reconstructions of thick filaments from striated muscle. These reconstructions are calculated by averaging methods using images from electron micrographs of grids prepared using numerous filament preparations. Here we propose an alternative method to calculate the 3D-reconstruction of a single thick filament using only a tilt series images recorded by electron tomography. Relaxed thick filaments, prepared from tarantula leg muscle homogenates, were negatively stained. Single-axis tilt series of single isolated thick filaments were obtained with the electron microscope at a low electron dose, and recorded on a CCD camera by electron tomography. An IHRSR 3D-recontruction was calculated from the tilt series images of a single thick filament. The reconstruction was enhanced by including in the search stage dual tilt image segments while only single tilt along the filament axis is usually used, as well as applying a band pass filter just before the back projection. The reconstruction from a single filament has a 40 Å resolution and clearly shows the presence of MIH motifs. In contrast, the electron tomogram 3D-reconstruction of the same thick filament - calculated without any image averaging and/or imposition of helical symmetry - only reveals MIH motifs infrequently. This is - to our knowledge - the first application of the IHRSR method to calculate a 3D reconstruction from tilt series images. This single filament IHRSR reconstruction method (SF-IHRSR) should provide a new tool to assess structural differences between well-ordered thick (or thin) filaments in a grid by recording separately their electron tomograms.

  16. Analytic reconstruction approach for parallel translational computed tomography.

    Science.gov (United States)

    Kong, Huihua; Yu, Hengyong

    2015-01-01

    To develop low-cost and low-dose computed tomography (CT) scanners for developing countries, recently a parallel translational computed tomography (PTCT) is proposed, and the source and detector are translated oppositely with respect to the imaging object without a slip-ring. In this paper, we develop an analytic filtered-backprojection (FBP)-type reconstruction algorithm for two dimensional (2D) fan-beam PTCT and extend it to three dimensional (3D) cone-beam geometry in a Feldkamp-type framework. Particularly, a weighting function is constructed to deal with data redundancy for multiple translations PTCT to eliminate image artifacts. Extensive numerical simulations are performed to validate and evaluate the proposed analytic reconstruction algorithms, and the results confirm their correctness and merits. PMID:25882732

  17. Automatic alignment and reconstruction of images for soft x-ray tomography

    OpenAIRE

    Parkinson, Dilworth Y.; Knoechel, Christian; Yang, Chao; Larabell, Carolyn A.; Le Gros, Mark A.

    2011-01-01

    Soft x-ray tomography (SXT) is a powerful imaging technique that generates quantitative, 3D images of the structural organization of whole cells in a near-native state. SXT is also a high-throughput imaging technique. At the National Center for X-ray Tomography (NCXT), specimen preparation and image collection for tomographic reconstruction of a whole cell require only minutes. Aligning and reconstructing the data, however, take significantly longer. Here we describe a new component of the hi...

  18. Reconstruction of 3D Shapes of Opaque Cumulus Clouds from Airborne Multiangle Imaging: A Proof-of-Concept

    Science.gov (United States)

    Davis, A. B.; Bal, G.; Chen, J.

    2015-12-01

    Operational remote sensing of microphysical and optical cloud properties is invariably predicated on the assumption of plane-parallel slab geometry for the targeted cloud. The sole benefit of this often-questionable assumption about the cloud is that it leads to one-dimensional (1D) radiative transfer (RT)---a textbook, computationally tractable model. We present new results as evidence that, thanks to converging advances in 3D RT, inverse problem theory, algorithm implementation, and computer hardware, we are at the dawn of a new era in cloud remote sensing where we can finally go beyond the plane-parallel paradigm. Granted, the plane-parallel/1D RT assumption is reasonable for spatially extended stratiform cloud layers, as well as the smoothly distributed background aerosol layers. However, these 1D RT-friendly scenarios exclude cases that are critically important for climate physics. 1D RT---whence operational cloud remote sensing---fails catastrophically for cumuliform clouds that have fully 3D outer shapes and internal structures driven by shallow or deep convection. For these situations, the first order of business in a robust characterization by remote sensing is to abandon the slab geometry framework and determine the 3D geometry of the cloud, as a first step toward bone fide 3D cloud tomography. With this specific goal in mind, we deliver a proof-of-concept for an entirely new kind of remote sensing applicable to 3D clouds. It is based on highly simplified 3D RT and exploits multi-angular suites of cloud images at high spatial resolution. Airborne sensors like AirMSPI readily acquire such data. The key element of the reconstruction algorithm is a sophisticated solution of the nonlinear inverse problem via linearization of the forward model and an iteration scheme supported, where necessary, by adaptive regularization. Currently, the demo uses a 2D setting to show how either vertical profiles or horizontal slices of the cloud can be accurately reconstructed

  19. Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

    Energy Technology Data Exchange (ETDEWEB)

    Glaser, Adam K., E-mail: Adam.K.Glaser@dartmouth.edu, E-mail: Brian.W.Pogue@dartmouth.edu; Andreozzi, Jacqueline M. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Zhang, Rongxiao [Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States); Pogue, Brian W., E-mail: Adam.K.Glaser@dartmouth.edu, E-mail: Brian.W.Pogue@dartmouth.edu [Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States); Gladstone, David J. [Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03766 (United States)

    2015-07-15

    Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

  20. Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

    International Nuclear Information System (INIS)

    Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm3 volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water

  1. Xenobiotic metabolism in human skin and 3D human skin reconstructs: A review

    NARCIS (Netherlands)

    Gibbs, S.; Sandt, J.J.M. van de; Merk, H.F.; Lockley, D.J.; Pendlington, R.U.; Pease, C.K.

    2007-01-01

    In this review, we discuss and compare studies of xenobiotic metabolism in both human skin and 3D human skin reconstructs. In comparison to the liver, the skin is a less studied organ in terms of characterising metabolic capability. While the skin forms the major protective barrier to environmental

  2. Model-free 3D face shape reconstruction from video sequences

    NARCIS (Netherlands)

    Dam, van Chris; Veldhuis, Raymond; Spreeuwers, Luuk

    2013-01-01

    In forensic comparison of facial video data, often only the best quality frontal face frames are selected, and hence much video data is ignored. To improve 2D facial comparison for law enforcement and forensic investigation, we introduce a model-free 3D shape reconstruction algorithm based on 2D lan

  3. Landmark-based model-free 3D face shape reconstruction from video sequences

    NARCIS (Netherlands)

    Dam, van Chris; Veldhuis, Raymond; Spreeuwers, Luuk; Broemme, A.; Busch, C.

    2013-01-01

    In forensic comparison of facial video data, often only the best quality frontal face frames are selected, and hence potentially useful video data is ignored. To improve 2D facial comparison for law enforcement and forensic investigation, we introduce a model-free 3D shape reconstruction algorithm b

  4. VizieR Online Data Catalog: ADAM: 3D asteroid shape reconstruction code (Viikinkoski+, 2015)

    Science.gov (United States)

    Viikinkoski, M.; Kaasalainen, M.; Durech, J.

    2015-02-01

    About the code: ADAM is a collection of routines for 3D asteroid shape reconstruction from disk-resolved observations. Any combination of lightcurves, adaptive optics images, HST/FGS data, range-Doppler radar images and disk-resolved thermal images may be used as data sources. The routines are implemented in a combination of MATLAB and C. (2 data files).

  5. Some Methods of Applied Numerical Analysis to 3d Facial Reconstruction Software

    Science.gov (United States)

    Roşu, Şerban; Ianeş, Emilia; Roşu, Doina

    2010-09-01

    This paper deals with the collective work performed by medical doctors from the University Of Medicine and Pharmacy Timisoara and engineers from the Politechnical Institute Timisoara in the effort to create the first Romanian 3d reconstruction software based on CT or MRI scans and to test the created software in clinical practice.

  6. Toward 3D Reconstruction of Outdoor Scenes Using an MMW Radar and a Monocular Vision Sensor

    Science.gov (United States)

    El Natour, Ghina; Ait-Aider, Omar; Rouveure, Raphael; Berry, François; Faure, Patrice

    2015-01-01

    In this paper, we introduce a geometric method for 3D reconstruction of the exterior environment using a panoramic microwave radar and a camera. We rely on the complementarity of these two sensors considering the robustness to the environmental conditions and depth detection ability of the radar, on the one hand, and the high spatial resolution of a vision sensor, on the other. Firstly, geometric modeling of each sensor and of the entire system is presented. Secondly, we address the global calibration problem, which consists of finding the exact transformation between the sensors’ coordinate systems. Two implementation methods are proposed and compared, based on the optimization of a non-linear criterion obtained from a set of radar-to-image target correspondences. Unlike existing methods, no special configuration of the 3D points is required for calibration. This makes the methods flexible and easy to use by a non-expert operator. Finally, we present a very simple, yet robust 3D reconstruction method based on the sensors’ geometry. This method enables one to reconstruct observed features in 3D using one acquisition (static sensor), which is not always met in the state of the art for outdoor scene reconstruction. The proposed methods have been validated with synthetic and real data. PMID:26473874

  7. Morphology and function of Bast's valve : additional insight in its functioning using 3D-reconstruction

    NARCIS (Netherlands)

    Hofman, R.; Segenhout, J. M.; Buytaert, J. A. N.; Dirckx, J. J. J.; Wit, H. P.

    2008-01-01

    The utriculo-endolymphatic valve was discovered by Bast in 1928. The function of Bast's valve is still unclear. By means of orthogonal-plane fluorescence optical sectioning (OPFOS) microscopy 3D-reconstructions of the valve and its surrounding region are depicted. The shape of the duct at the utricu

  8. Estimation of 3D reconstruction errors in a stereo-vision system

    Science.gov (United States)

    Belhaoua, A.; Kohler, S.; Hirsch, E.

    2009-06-01

    The paper presents an approach for error estimation for the various steps of an automated 3D vision-based reconstruction procedure of manufactured workpieces. The process is based on a priori planning of the task and built around a cognitive intelligent sensory system using so-called Situation Graph Trees (SGT) as a planning tool. Such an automated quality control system requires the coordination of a set of complex processes performing sequentially data acquisition, its quantitative evaluation and the comparison with a reference model (e.g., CAD object model) in order to evaluate quantitatively the object. To ensure efficient quality control, the aim is to be able to state if reconstruction results fulfill tolerance rules or not. Thus, the goal is to evaluate independently the error for each step of the stereo-vision based 3D reconstruction (e.g., for calibration, contour segmentation, matching and reconstruction) and then to estimate the error for the whole system. In this contribution, we analyze particularly the segmentation error due to localization errors for extracted edge points supposed to belong to lines and curves composing the outline of the workpiece under evaluation. The fitting parameters describing these geometric features are used as quality measure to determine confidence intervals and finally to estimate the segmentation errors. These errors are then propagated through the whole reconstruction procedure, enabling to evaluate their effect on the final 3D reconstruction result, specifically on position uncertainties. Lastly, analysis of these error estimates enables to evaluate the quality of the 3D reconstruction, as illustrated by the shown experimental results.

  9. Non-periodic 3-D motion estimation and reconstruction of coronary stents

    International Nuclear Information System (INIS)

    C-arm CT enables 3-D imaging at high spatial resolution. Image quality would be sufficient for coronary artery stents at rest. However, spatial resolution is severely degraded by cardiac motion which needs to be considered in the reconstruction step. Existing approaches are based on detecting markers in the projection images. Based on the exact marker locations in all images, motion estimation and compensation is performed in the 2-D projection image domain and thus no 3-D motion information of the stent is available. In this paper a novel method for computing the non-periodic location of the stent markers in 3-D is proposed. The motion estimation step comprises marker detection in 2-D, computation of periodic 3-D motion and computation of non-periodic 3-D motion. For motion compensation the 3- D marker positions are used to compute an affine motion model as input for a motion compensated FDK reconstruction algorithm. First clinical results suggest a high image quality and the possibility to compute physiological parameters e.g. velocity curves. (orig.)

  10. 3D Surface Reconstruction of Plant Seeds by Volume Carving: Performance and Accuracies

    Science.gov (United States)

    Roussel, Johanna; Geiger, Felix; Fischbach, Andreas; Jahnke, Siegfried; Scharr, Hanno

    2016-01-01

    We describe a method for 3D reconstruction of plant seed surfaces, focusing on small seeds with diameters as small as 200 μm. The method considers robotized systems allowing single seed handling in order to rotate a single seed in front of a camera. Even though such systems feature high position repeatability, at sub-millimeter object scales, camera pose variations have to be compensated. We do this by robustly estimating the tool center point from each acquired image. 3D reconstruction can then be performed by a simple shape-from-silhouette approach. In experiments we investigate runtimes, theoretically achievable accuracy, experimentally achieved accuracy, and show as a proof of principle that the proposed method is well sufficient for 3D seed phenotyping purposes. PMID:27375628

  11. A Computer Vision Method for 3D Reconstruction of Curves-Marked Free-Form Surfaces

    Institute of Scientific and Technical Information of China (English)

    Xiong Hanwei; Zhang Xiangwei

    2001-01-01

    Visual method is now broadly used in reverse engineering for 3D reconstruction. Thetraditional computer vision methods are feature-based, i.e., they require that the objects must revealfeatures owing to geometry or textures. For textureless free-form surfaces, dense feature points areadded artificially. In this paper, a new method is put forward combining computer vision with CAGD.The surface is subdivided into N-side Gregory patches using marked curves, and a stereo algorithm isused to reconstruct the curves. Then, the cross boundary tangent vector is computed throughreflectance analysis. At last, the whole surface can be reconstructed by jointing these patches withG1 continuity.

  12. Enhancement of 3D modeling and classification of microcalcifications in breast computed tomography (BCT)

    Science.gov (United States)

    Alquran, Hiam; Shaheen, Eman; O'Connor, J. Michael; Mahd, Mufeed

    2014-03-01

    Current computer aided diagnosis (CADx) software for digital mammography relies mainly on 2D techniques. With the emergence of three-dimensional (3D) breast imaging modalities such as breast Computed Tomography (BCT), there is an opportunity to analyze 3D features in the classification of calcifications. We previously reported our initial work on automated 3D feature detection and classification based on morphological descriptions for single microcalcifications within clusters [1]. In this work, we propose the expansion of the 3D classification methods to include novel microcalcification morphological feature detection such as including more morphological classes and replacing the 2D Radon transform by a 3D Radon transform. Results show that the classification rate improved compared to the previously reported results from a total of 546 to 559 consistently classified calcifications out of 635 total calcifications. This slight improvement is due to the use of the 3D Radon transform and incorporating methods to detect two classes not previously implemented. Future work will focus on adding feature detection and classification of cluster patterns.

  13. Design and evaluation of a laboratory prototype system for 3D photoacoustic full breast tomography

    OpenAIRE

    Xia, W; Piras, D; Singh, M. K. A.; van Hespen, J. C. G.; Van Leeuwen, T. G.; Steenbergen, W Van; Manohar, S.

    2013-01-01

    Photoacoustic imaging can visualize vascularization-driven optical absorption contrast with great potential for breast cancer detection and diagnosis. State-of-the-art photoacoustic breast imaging systems are promising but are limited either by only a 2D imaging capability or by an insufficient imaging field-of-view (FOV). We present a laboratory prototype system designed for 3D photoacoustic full breast tomography, and comprehensively characterize it and evaluate its performance in imaging p...

  14. Automatic 3d Building Reconstruction from a Dense Image Matching Dataset

    Science.gov (United States)

    McClune, Andrew P.; Mills, Jon P.; Miller, Pauline E.; Holland, David A.

    2016-06-01

    Over the last 20 years the demand for three dimensional (3D) building models has resulted in a vast amount of research being conducted in attempts to automate the extraction and reconstruction of models from airborne sensors. Recent results have shown that current methods tend to favour planar fitting procedures from lidar data, which are able to successfully reconstruct simple roof structures automatically but fail to reconstruct more complex structures or roofs with small artefacts. Current methods have also not fully explored the potential of recent developments in digital photogrammetry. Large format digital aerial cameras can now capture imagery with increased overlap and a higher spatial resolution, increasing the number of pixel correspondences between images. Every pixel in each stereo pair can also now be matched using per-pixel algorithms, which has given rise to the approach known as dense image matching. This paper presents an approach to 3D building reconstruction to try and overcome some of the limitations of planar fitting procedures. Roof vertices, extracted from true-orthophotos using edge detection, are refined and converted to roof corner points. By determining the connection between extracted corner points, a roof plane can be defined as a closed-cycle of points. Presented results demonstrate the potential of this method for the reconstruction of complex 3D building models at CityGML LoD2 specification.

  15. Recovery and Visualization of 3D Structure of Chromosomes from Tomographic Reconstruction Images

    Directory of Open Access Journals (Sweden)

    Tsap Leonid V

    2006-01-01

    Full Text Available The objectives of this work include automatic recovery and visualization of a 3D chromosome structure from a sequence of 2D tomographic reconstruction images taken through the nucleus of a cell. Structure is very important for biologists as it affects chromosome functions, behavior of the cell, and its state. Analysis of chromosome structure is significant in the detection of diseases, identification of chromosomal abnormalities, study of DNA structural conformation, in-depth study of chromosomal surface morphology, observation of in vivo behavior of the chromosomes over time, and in monitoring environmental gene mutations. The methodology incorporates thresholding based on a histogram analysis with a polyline splitting algorithm, contour extraction via active contours, and detection of the 3D chromosome structure by establishing corresponding regions throughout the slices. Visualization using point cloud meshing generates a 3D surface. The 3D triangular mesh of the chromosomes provides surface detail and allows a user to interactively analyze chromosomes using visualization software.

  16. 3-D Multiphase Segmentation of X-Ray Micro Computed Tomography Data of Geologic Materials

    Science.gov (United States)

    Tuller, M.; Kulkarni, R.; Fink, W.

    2011-12-01

    Advancements of noninvasive imaging methods such as X-Ray Computed Tomography (CT) led to a recent surge of applications in Geoscience. While substantial efforts and resources have been devoted to advance CT technology and micro-scale analysis, the development of a stable 3-D multiphase image segmentation method applicable to large datasets is lacking. To eliminate the need for wet/dry or dual energy scans, image alignment, and subtraction analysis, commonly applied in synchrotron X-Ray micro CT, a segmentation method based on a Bayesian Markov Random Field (MRF) framework amenable to true 3-D multiphase processing was developed and evaluated. Furthermore, several heuristic and deterministic combinatorial optimization schemes required to solve the labeling problem of the MRF image model were implemented and tested for computational efficiency and their impact on segmentation results. Test results for natural and artificial porous media datasets demonstrate great potential of the MRF image model for 3-D multiphase segmentation.

  17. Internet2-based 3D PET image reconstruction using a PC cluster.

    Science.gov (United States)

    Shattuck, D W; Rapela, J; Asma, E; Chatzioannou, A; Qi, J; Leahy, R M

    2002-08-01

    We describe an approach to fast iterative reconstruction from fully three-dimensional (3D) PET data using a network of PentiumIII PCs configured as a Beowulf cluster. To facilitate the use of this system, we have developed a browser-based interface using Java. The system compresses PET data on the user's machine, sends these data over a network, and instructs the PC cluster to reconstruct the image. The cluster implements a parallelized version of our preconditioned conjugate gradient method for fully 3D MAP image reconstruction. We report on the speed-up factors using the Beowulf approach and the impacts of communication latencies in the local cluster network and the network connection between the user's machine and our PC cluster.

  18. Modifications in SIFT-based 3D reconstruction from image sequence

    Science.gov (United States)

    Wei, Zhenzhong; Ding, Boshen; Wang, Wei

    2014-11-01

    In this paper, we aim to reconstruct 3D points of the scene from related images. Scale Invariant Feature Transform( SIFT) as a feature extraction and matching algorithm has been proposed and improved for years and has been widely used in image alignment and stitching, image recognition and 3D reconstruction. Because of the robustness and reliability of the SIFT's feature extracting and matching algorithm, we use it to find correspondences between images. Hence, we describe a SIFT-based method to reconstruct 3D sparse points from ordered images. In the process of matching, we make a modification in the process of finding the correct correspondences, and obtain a satisfying matching result. By rejecting the "questioned" points before initial matching could make the final matching more reliable. Given SIFT's attribute of being invariant to the image scale, rotation, and variable changes in environment, we propose a way to delete the multiple reconstructed points occurred in sequential reconstruction procedure, which improves the accuracy of the reconstruction. By removing the duplicated points, we avoid the possible collapsed situation caused by the inexactly initialization or the error accumulation. The limitation of some cases that all reprojected points are visible at all times also does not exist in our situation. "The small precision" could make a big change when the number of images increases. The paper shows the contrast between the modified algorithm and not. Moreover, we present an approach to evaluate the reconstruction by comparing the reconstructed angle and length ratio with actual value by using a calibration target in the scene. The proposed evaluation method is easy to be carried out and with a great applicable value. Even without the Internet image datasets, we could evaluate our own results. In this paper, the whole algorithm has been tested on several image sequences both on the internet and in our shots.

  19. A novel approximation method of CTF amplitude correction for 3D single particle reconstruction

    International Nuclear Information System (INIS)

    The typical resolution of three-dimensional reconstruction by cryo-EM single particle analysis is now being pushed up to and beyond the nanometer scale. Correction of the contrast transfer function (CTF) of electron microscopic images is essential for achieving such a high resolution. Various correction methods exist and are employed in popular reconstruction software packages. Here, we present a novel approximation method that corrects the amplitude modulation introduced by the contrast transfer function by convoluting the images with a piecewise continuous function. Our new approach can easily be implemented and incorporated into other packages. The implemented method yielded higher resolution reconstructions with data sets from both highly symmetric and asymmetric structures. It is an efficient alternative correction method that allows quick convergence of the 3D reconstruction and has a high tolerance for noisy images, thus easing a bottleneck in practical reconstruction of macromolecules.

  20. 3-D analysis of dictyosomes and multivesicular bodies in the green alga Micrasterias denticulata by FIB/SEM tomography.

    Science.gov (United States)

    Wanner, Gerhard; Schäfer, Tillman; Lütz-Meindl, Ursula

    2013-11-01

    In the present study we employ FIB/SEM tomography for analyzing 3-D architecture of dictyosomes and formation of multivesicular bodies (MVB) in high pressure frozen and cryo-substituted interphase cells of the green algal model system Micrasterias denticulata. The ability of FIB/SEM of milling very thin 'slices' (5-10 nm), viewing the block face and of capturing cytoplasmic volumes of several hundred μm(3) provides new insight into the close spatial connection of the ER-Golgi machinery in an algal cell particularly in z-direction, complementary to informations obtained by TEM serial sectioning or electron tomography. Our FIB/SEM series and 3-D reconstructions show that interphase dictyosomes of Micrasterias are not only closely associated to an ER system at their cis-side which is common in various plant cells, but are surrounded by a huge "trans-ER" sheath leading to an almost complete enwrapping of dictyosomes by the ER. This is particularly interesting as the presence of a trans-dictyosomal ER system is well known from mammalian secretory cells but not from cells of higher plants to which the alga Micrasterias is closely related. In contrast to findings in plant storage tissue indicating that MVBs originate from the trans-Golgi network or its derivatives our investigations show that MVBs in Micrasterias are in direct spatial contact with both, trans-Golgi cisternae and the trans-ER sheath which provides evidence that both endomembrane compartments are involved in their formation.

  1. Image reconstruction for robot assisted ultrasound tomography

    Science.gov (United States)

    Aalamifar, Fereshteh; Zhang, Haichong K.; Rahmim, Arman; Boctor, Emad M.

    2016-04-01

    An investigation of several image reconstruction methods for robot-assisted ultrasound (US) tomography setup is presented. In the robot-assisted setup, an expert moves the US probe to the location of interest, and a robotic arm automatically aligns another US probe with it. The two aligned probes can then transmit and receive US signals which are subsequently used for tomographic reconstruction. This study focuses on reconstruction of the speed of sound. In various simulation evaluations as well as in an experiment with a millimeter-range inaccuracy, we demonstrate that the limited data provided by two probes can be used to reconstruct pixel-wise images differentiating between media with different speeds of sound. Combining the results of this investigation with the developed robot-assisted US tomography setup, we envision feasibility of this setup for tomographic imaging in applications beyond breast imaging, with potentially significant efficacy in cancer diagnosis.

  2. Reconstructions in ultrasound modulated optical tomography

    KAUST Repository

    Allmaras, Moritz

    2011-01-01

    We introduce a mathematical model for ultrasound modulated optical tomography and present a simple reconstruction scheme for recovering the spatially varying optical absorption coefficient from scanning measurements with narrowly focused ultrasound signals. Computational results for this model show that the reconstruction of sharp features of the absorption coefficient is possible. A formal linearization of the model leads to an equation with a Fredholm operator, which explains the stability observed in our numerical experiments. © de Gruyter 2011.

  3. 3D Maize Plant Reconstruction Based on Georeferenced Overlapping LiDAR Point Clouds

    Directory of Open Access Journals (Sweden)

    Miguel Garrido

    2015-12-01

    Full Text Available 3D crop reconstruction with a high temporal resolution and by the use of non-destructive measuring technologies can support the automation of plant phenotyping processes. Thereby, the availability of such 3D data can give valuable information about the plant development and the interaction of the plant genotype with the environment. This article presents a new methodology for georeferenced 3D reconstruction of maize plant structure. For this purpose a total station, an IMU, and several 2D LiDARs with different orientations were mounted on an autonomous vehicle. By the multistep methodology presented, based on the application of the ICP algorithm for point cloud fusion, it was possible to perform the georeferenced point clouds overlapping. The overlapping point cloud algorithm showed that the aerial points (corresponding mainly to plant parts were reduced to 1.5%–9% of the total registered data. The remaining were redundant or ground points. Through the inclusion of different LiDAR point of views of the scene, a more realistic representation of the surrounding is obtained by the incorporation of new useful information but also of noise. The use of georeferenced 3D maize plant reconstruction at different growth stages, combined with the total station accuracy could be highly useful when performing precision agriculture at the crop plant level.

  4. Multi-view 3D scene reconstruction using ant colony optimization techniques

    International Nuclear Information System (INIS)

    This paper presents a new method performing high-quality 3D object reconstruction of complex shapes derived from multiple, calibrated photographs of the same scene. The novelty of this research is found in two basic elements, namely: (i) a novel voxel dissimilarity measure, which accommodates the elimination of the lighting variations of the models and (ii) the use of an ant colony approach for further refinement of the final 3D models. The proposed reconstruction procedure employs a volumetric method based on a novel projection test for the production of a visual hull. While the presented algorithm shares certain aspects with the space carving algorithm, it is, nevertheless, first enhanced with the lightness compensating image comparison method, and then refined using ant colony optimization. The algorithm is fast, computationally simple and results in accurate representations of the input scenes. In addition, compared to previous publications, the particular nature of the proposed algorithm allows accurate 3D volumetric measurements under demanding lighting environmental conditions, due to the fact that it can cope with uneven light scenes, resulting from the characteristics of the voxel dissimilarity measure applied. Besides, the intelligent behavior of the ant colony framework provides the opportunity to formulate the process as a combinatorial optimization problem, which can then be solved by means of a colony of cooperating artificial ants, resulting in very promising results. The method is validated with several real datasets, along with qualitative comparisons with other state-of-the-art 3D reconstruction techniques, following the Middlebury benchmark. (paper)

  5. Orbital Wall Reconstruction with Two-Piece Puzzle 3D Printed Implants: Technical Note.

    Science.gov (United States)

    Mommaerts, Maurice Y; Büttner, Michael; Vercruysse, Herman; Wauters, Lauri; Beerens, Maikel

    2016-03-01

    The purpose of this article is to describe a technique for secondary reconstruction of traumatic orbital wall defects using titanium implants that act as three-dimensional (3D) puzzle pieces. We present three cases of large defect reconstruction using implants produced by Xilloc Medical B.V. (Maastricht, the Netherlands) with a 3D printer manufactured by LayerWise (3D Systems; Heverlee, Belgium), and designed using the biomedical engineering software programs ProPlan and 3-Matic (Materialise, Heverlee, Belgium). The smaller size of the implants allowed sequential implantation for the reconstruction of extensive two-wall defects via a limited transconjunctival incision. The precise fit of the implants with regard to the surrounding ledges and each other was confirmed by intraoperative 3D imaging (Mobile C-arm Systems B.V. Pulsera, Philips Medical Systems, Eindhoven, the Netherlands). The patients showed near-complete restoration of orbital volume and ocular motility. However, challenges remain, including traumatic fat atrophy and fibrosis. PMID:26889349

  6. Virtual 3D bladder reconstruction for augmented medical records from white light cystoscopy (Conference Presentation)

    Science.gov (United States)

    Lurie, Kristen L.; Zlatev, Dimitar V.; Angst, Roland; Liao, Joseph C.; Ellerbee, Audrey K.

    2016-02-01

    Bladder cancer has a high recurrence rate that necessitates lifelong surveillance to detect mucosal lesions. Examination with white light cystoscopy (WLC), the standard of care, is inherently subjective and data storage limited to clinical notes, diagrams, and still images. A visual history of the bladder wall can enhance clinical and surgical management. To address this clinical need, we developed a tool to transform in vivo WLC videos into virtual 3-dimensional (3D) bladder models using advanced computer vision techniques. WLC videos from rigid cystoscopies (1280 x 720 pixels) were recorded at 30 Hz followed by immediate camera calibration to control for image distortions. Video data were fed into an automated structure-from-motion algorithm that generated a 3D point cloud followed by a 3D mesh to approximate the bladder surface. The highest quality cystoscopic images were projected onto the approximated bladder surface to generate a virtual 3D bladder reconstruction. In intraoperative WLC videos from 36 patients undergoing transurethral resection of suspected bladder tumors, optimal reconstruction was achieved from frames depicting well-focused vasculature, when the bladder was maintained at constant volume with minimal debris, and when regions of the bladder wall were imaged multiple times. A significant innovation of this work is the ability to perform the reconstruction using video from a clinical procedure collected with standard equipment, thereby facilitating rapid clinical translation, application to other forms of endoscopy and new opportunities for longitudinal studies of cancer recurrence.

  7. Real-Time Large Scale 3d Reconstruction by Fusing Kinect and Imu Data

    Science.gov (United States)

    Huai, J.; Zhang, Y.; Yilmaz, A.

    2015-08-01

    Kinect-style RGB-D cameras have been used to build large scale dense 3D maps for indoor environments. These maps can serve many purposes such as robot navigation, and augmented reality. However, to generate dense 3D maps of large scale environments is still very challenging. In this paper, we present a mapping system for 3D reconstruction that fuses measurements from a Kinect and an inertial measurement unit (IMU) to estimate motion. Our major achievements include: (i) Large scale consistent 3D reconstruction is realized by volume shifting and loop closure; (ii) The coarse-to-fine iterative closest point (ICP) algorithm, the SIFT odometry, and IMU odometry are combined to robustly and precisely estimate pose. In particular, ICP runs routinely to track the Kinect motion. If ICP fails in planar areas, the SIFT odometry provides incremental motion estimate. If both ICP and the SIFT odometry fail, e.g., upon abrupt motion or inadequate features, the incremental motion is estimated by the IMU. Additionally, the IMU also observes the roll and pitch angles which can reduce long-term drift of the sensor assembly. In experiments on a consumer laptop, our system estimates motion at 8Hz on average while integrating color images to the local map and saving volumes of meshes concurrently. Moreover, it is immune to tracking failures, and has smaller drift than the state-of-the-art systems in large scale reconstruction.

  8. Real-Time 3d Reconstruction from Images Taken from AN Uav

    Science.gov (United States)

    Zingoni, A.; Diani, M.; Corsini, G.; Masini, A.

    2015-08-01

    We designed a method for creating 3D models of objects and areas from two aerial images acquired from an UAV. The models are generated automatically and in real-time, and consist in dense and true-colour reconstructions of the considered areas, which give the impression to the operator to be physically present within the scene. The proposed method only needs a cheap compact camera, mounted on a small UAV. No additional instrumentation is necessary, so that the costs are very limited. The method consists of two main parts: the design of the acquisition system and the 3D reconstruction algorithm. In the first part, the choices for the acquisition geometry and for the camera parameters are optimized, in order to yield the best performance. In the second part, a reconstruction algorithm extracts the 3D model from the two acquired images, maximizing the accuracy under the real-time constraint. A test was performed in monitoring a construction yard, obtaining very promising results. Highly realistic and easy-to-interpret 3D models of objects and areas of interest were produced in less than one second, with an accuracy of about 0.5m. For its characteristics, the designed method is suitable for video-surveillance, remote sensing and monitoring, especially in those applications that require intuitive and reliable information quickly, as disasters monitoring, search and rescue and area surveillance.

  9. Reconstruction of axisymmetric strain distributions via neutron strain tomography

    International Nuclear Information System (INIS)

    Predicting the behaviour of structural components under a particular set of loading conditions requires knowledge of the residual elastic strain distribution throughout the bulk of these components. Characterising the 3D strain state at any particular point involves the measurement of six independent components which make up the second order strain tensor. Mapping the complete strain distribution throughout large volumes thus presents significant practical challenges. One possible solution to this problem is to reconstruct the 3D variation of strain components using tomographic techniques. The basic principle underpinning this idea is that the multi-component strain tensor can be reconstructed from a redundant set of lower order projection data. Here we demonstrate this fundamental concept for two samples: a shrink fit ‘ring-and-plug’ sample, and a spray-quenched circular cylinder, both possessing axially symmetric internal strain distribution. We present and contrast different approaches to the strain tomography problem. The methods described here can also be readily applied to high-energy X-ray diffraction measurements and represent an important step toward developing the tomographic reconstruction framework for strain tensor distributions of arbitrary complexity. The major benefit of neutron strain tomography is that the incident beam flux is utilised more fully, greatly reducing the data collection times. Using micro-channel plate (MCP) neutron detectors, a spatial resolution of the order of 0.1 mm can be achieved .

  10. Recursive 3D-reconstruction of structured scenes using a moving camera - application to robotics

    International Nuclear Information System (INIS)

    This thesis is devoted to the perception of a structured environment, and proposes a new method which allows a 3D-reconstruction of an interesting part of the world using a mobile camera. Our work is divided into three essential parts dedicated to 2D-information aspect, 3D-information aspect, and a validation of the method. In the first part, we present a method which produces a topologic and geometric image representation based on 'segment' and 'junction' features. Then, a 2D-matching method based on a hypothesis prediction and verification algorithm is proposed to match features issued from two successive images. The second part deals with 3D-reconstruction using a triangulation technique, and discuses our new method introducing an 'Estimation-Construction-Fusion' process. This ensures a complete and accurate 3D-representation, and a permanent position estimation of the camera with respect to the model. The merging process allows refinement of the 3D-representation using a powerful tool: a Kalman Filter. In the last part, experimental results issued from simulated and real data images are reported to show the efficiency of the method. (author)

  11. Reconstruction of 3-D cloud geometry using a scanning cloud radar

    Directory of Open Access Journals (Sweden)

    F. Ewald

    2014-11-01

    Full Text Available Clouds are one of the main reasons of uncertainties in the forecasts of weather and climate. In part, this is due to limitations of remote sensing of cloud microphysics. Present approaches often use passive spectral measurements for the remote sensing of cloud microphysical parameters. Large uncertainties are introduced by three dimensional (3-D radiative transfer effects and cloud inhomogeneities. Such effects are largely caused by unknown orientation of cloud sides or by shadowed areas on the cloud. Passive ground based remote sensing of cloud properties at high spatial resolution could be improved crucially with this kind of additional knowledge of cloud geometry. To this end, a method for the accurate reconstruction of 3-D cloud geometry from cloud radar measurements is developed in this work. Using a radar simulator and simulated passive measurements of static LES model clouds, the effects of different radar scan resolutions and varying interpolation methods are evaluated. In reality a trade-off between scan resolution and scan duration has to be found as clouds are changing quickly. A reasonable choice is a scan resolution of 1 to 2°. The most suitable interpolation procedure identified is the barycentric interpolation method. The 3-D reconstruction method is demonstrated using radar scans of convective cloud cases with the Munich miraMACS, a 35 GHz scanning cloud radar. As a successful proof of concept, camera imagery collected at the radar location is reproduced for the observed cloud cases via 3-D volume reconstruction and 3-D radiative transfer simulation. Data sets provided by the presented reconstruction method will aid passive spectral ground-based measurements of cloud sides to retrieve microphysical parameters.

  12. A Bayesian approach for suppression of limited angular sampling artifacts in single particle 3D reconstruction.

    Science.gov (United States)

    Moriya, Toshio; Acar, Erman; Cheng, R Holland; Ruotsalainen, Ulla

    2015-09-01

    In the single particle reconstruction, the initial 3D structure often suffers from the limited angular sampling artifact. Selecting 2D class averages of particle images generally improves the accuracy and efficiency of the reference-free 3D angle estimation, but causes an insufficient angular sampling to fill the information of the target object in the 3D frequency space. Similarly, the initial 3D structure by the random-conical tilt reconstruction has the well-known "missing cone" artifact. Here, we attempted to solve the limited angular sampling problem by sequentially applying maximum a posteriori estimate with expectation maximization algorithm (sMAP-EM). Using both simulated and experimental cryo-electron microscope images, the sMAP-EM was compared to the direct Fourier method on the basis of reconstruction error and resolution. To establish selection criteria of the final regularization weight for the sMAP-EM, the effects of noise level and sampling sparseness on the reconstructions were examined with evenly distributed sampling simulations. The frequency information filled in the missing cone of the conical tilt sampling simulations was assessed by developing new quantitative measurements. All the results of visual and numerical evaluations showed the sMAP-EM performed better than the direct Fourier method, regardless of the sampling method, noise level, and sampling sparseness. Furthermore, the frequency domain analysis demonstrated that the sMAP-EM can fill the meaningful information in the unmeasured angular space without detailed a priori knowledge of the objects. The current research demonstrated that the sMAP-EM has a high potential to facilitate the determination of 3D protein structures at near atomic-resolution. PMID:26193484

  13. 3D-guided CT reconstruction using time-of-flight camera

    Science.gov (United States)

    Ismail, Mahmoud; Taguchi, Katsuyuki; Xu, Jingyan; Tsui, Benjamin M. W.; Boctor, Emad M.

    2011-03-01

    We propose the use of a time-of-flight (TOF) camera to obtain the patient's body contour in 3D guided imaging reconstruction scheme in CT and C-arm imaging systems with truncated projection. In addition to pixel intensity, a TOF camera provides the 3D coordinates of each point in the captured scene with respect to the camera coordinates. Information from the TOF camera was used to obtain a digitized surface of the patient's body. The digitization points are transformed to X-Ray detector coordinates by registering the two coordinate systems. A set of points corresponding to the slice of interest are segmented to form a 2D contour of the body surface. Radon transform is applied to the contour to generate the 'trust region' for the projection data. The generated 'trust region' is integrated as an input to augment the projection data. It is used to estimate the truncated, unmeasured projections using linear interpolation. Finally the image is reconstructed using the combination of the estimated and the measured projection data. The proposed method is evaluated using a physical phantom. Projection data for the phantom were obtained using a C-arm system. Significant improvement in the reconstructed image quality near the truncation edges was observed using the proposed method as compared to that without truncation correction. This work shows that the proposed 3D guided CT image reconstruction using a TOF camera represents a feasible solution to the projection data truncation problem.

  14. Intuitive Terrain Reconstruction Using Height Observation-Based Ground Segmentation and 3D Object Boundary Estimation

    Directory of Open Access Journals (Sweden)

    Sungdae Sim

    2012-12-01

    Full Text Available Mobile robot operators must make rapid decisions based on information about the robot’s surrounding environment. This means that terrain modeling and photorealistic visualization are required for the remote operation of mobile robots. We have produced a voxel map and textured mesh from the 2D and 3D datasets collected by a robot’s array of sensors, but some upper parts of objects are beyond the sensors’ measurements and these parts are missing in the terrain reconstruction result. This result is an incomplete terrain model. To solve this problem, we present a new ground segmentation method to detect non-ground data in the reconstructed voxel map. Our method uses height histograms to estimate the ground height range, and a Gibbs-Markov random field model to refine the segmentation results. To reconstruct a complete terrain model of the 3D environment, we develop a 3D boundary estimation method for non-ground objects. We apply a boundary detection technique to the 2D image, before estimating and refining the actual height values of the non-ground vertices in the reconstructed textured mesh. Our proposed methods were tested in an outdoor environment in which trees and buildings were not completely sensed. Our results show that the time required for ground segmentation is faster than that for data sensing, which is necessary for a real-time approach. In addition, those parts of objects that were not sensed are accurately recovered to retrieve their real-world appearances.

  15. Intuitive terrain reconstruction using height observation-based ground segmentation and 3D object boundary estimation.

    Science.gov (United States)

    Song, Wei; Cho, Kyungeun; Um, Kyhyun; Won, Chee Sun; Sim, Sungdae

    2012-12-12

    Mobile robot operators must make rapid decisions based on information about the robot's surrounding environment. This means that terrain modeling and photorealistic visualization are required for the remote operation of mobile robots. We have produced a voxel map and textured mesh from the 2D and 3D datasets collected by a robot's array of sensors, but some upper parts of objects are beyond the sensors' measurements and these parts are missing in the terrain reconstruction result. This result is an incomplete terrain model. To solve this problem, we present a new ground segmentation method to detect non-ground data in the reconstructed voxel map. Our method uses height histograms to estimate the ground height range, and a Gibbs-Markov random field model to refine the segmentation results. To reconstruct a complete terrain model of the 3D environment, we develop a 3D boundary estimation method for non-ground objects. We apply a boundary detection technique to the 2D image, before estimating and refining the actual height values of the non-ground vertices in the reconstructed textured mesh. Our proposed methods were tested in an outdoor environment in which trees and buildings were not completely sensed. Our results show that the time required for ground segmentation is faster than that for data sensing, which is necessary for a real-time approach. In addition, those parts of objects that were not sensed are accurately recovered to retrieve their real-world appearances.

  16. Benchmarking Close-range Structure from Motion 3D Reconstruction Software under Varying Capturing Conditions

    DEFF Research Database (Denmark)

    Nikolov, Ivan Adriyanov; Madsen, Claus B.

    2016-01-01

    . In this paper we analyse the state of the art of these software applications, by comparing the resultant 3D meshes qualitatively and quantitatively. We propose a number of testing scenarios using different lighting conditions, camera positions and image acquisition methods for the best in-depth analysis......Structure from Motion 3D reconstruction has become widely used in recent years in a number of fields such as industrial surface in- inspection, archeology, cultural heritage preservation and geomapping. A number of software solutions have been released using variations of this technique...

  17. Objective and subjective quality assessment of geometry compression of reconstructed 3D Humans in a 3D virtual room

    NARCIS (Netherlands)

    Mekuria, R.N.; Cesar Garcia, P.S.; Frisiello, A.; Doumanis, I.

    2015-01-01

    Compression of 3D object based video is relevant for 3D Immersive applications. Nevertheless, the perceptual aspects of the degradation introduced by codecs for meshes and point clouds are not well understood. In this paper we evaluate the subjective and objective degradations introduced by such cod

  18. Hybrid fluorescence tomography/x-ray tomography improves reconstruction quality

    Science.gov (United States)

    Schulz, R. B.; Ale, A.; Sarantopoulos, A.; Freyer, M.; Söhngen, R.; Zientkowska, M.; Ntziachristos, V.

    2009-07-01

    A novel hybrid imaging system for simultaneous X-ray and Fluorescence Tomography is presented, capitalizing on 360°-projection free-space fluorescence tomography. The system is implemented within a commercial micro-CT scanner allowing reconstructions with a resolution of 95μm. Acquired data sets are intrinsically coregistered in the same coordinate system and can be used to correctly localize reconstructed fluorescence distributions with morphological features. More importantly, the micro-CT data, automatically segmented into different organ and tissue segments can be used to guide the fluorescence reconstruction algorithm and reduce the ill coditioning of the inverse problem. We showcase the use of the system and the improvements in image quality for lesions in brain and lung.

  19. A comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: On 3D model accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xin, E-mail: Xin.Liang@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); College of Stomatology, Dalian Medical University (China); Lambrichts, Ivo, E-mail: Ivo.Lambrichts@uhasselt.b [Department of Basic Medical Sciences, Histology and Electron Microscopy, Faculty of Medicine, University of Hasselt, Diepenbeek (Belgium); Sun Yi, E-mail: Sunyihello@hotmail.co [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Denis, Kathleen, E-mail: kathleen.denis@groept.b [Department of Industrial Sciences and Techology-Engineering (IWT), XIOS Hogeschool Limburg, Hasselt (Belgium); Hassan, Bassam, E-mail: b.hassan@acta.n [Department of Oral Radiology, Academic Centre for Dentistry Amsterdam (ACTA), Amsterdam (Netherlands); Li Limin, E-mail: Limin.Li@uz.kuleuven.b [Department of Paediatric Dentistry and Special Dental Care, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Pauwels, Ruben, E-mail: Ruben.Pauwels@med.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium); Jacobs, Reinhilde, E-mail: Reinhilde.Jacobs@uz.kuleuven.b [Oral Imaging Centre, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Faculty of Medicine, Catholic University of Leuven (Belgium)

    2010-08-15

    Aim: The study aim was to compare the geometric accuracy of three-dimensional (3D) surface model reconstructions between five Cone Beam Computed Tomography (CBCT) scanners and one Multi-Slice CT (MSCT) system. Materials and methods: A dry human mandible was scanned with five CBCT systems (NewTom 3G, Accuitomo 3D, i-CAT, Galileos, Scanora 3D) and one MSCT scanner (Somatom Sensation 16). A 3D surface bone model was created from the six systems. The reference (gold standard) 3D model was obtained with a high resolution laser surface scanner. The 3D models from the five systems were compared with the gold standard using a point-based rigid registration algorithm. Results: The mean deviation from the gold standard for MSCT was 0.137 mm and for CBCT were 0.282, 0.225, 0.165, 0.386 and 0.206 mm for the i-CAT, Accuitomo, NewTom, Scanora and Galileos, respectively. Conclusion: The results show that the accuracy of CBCT 3D surface model reconstructions is somewhat lower but acceptable comparing to MSCT from the gold standard.

  20. GlaRe, a GIS tool to reconstruct the 3D surface of palaeoglaciers

    Science.gov (United States)

    Pellitero, Ramón; Rea, Brice R.; Spagnolo, Matteo; Bakke, Jostein; Ivy-Ochs, Susan; Frew, Craig R.; Hughes, Philip; Ribolini, Adriano; Lukas, Sven; Renssen, Hans

    2016-09-01

    Glacier reconstructions are widely used in palaeoclimatic studies and this paper presents a new semi-automated method for generating glacier reconstructions: GlaRe, is a toolbox coded in Python and operating in ArcGIS. This toolbox provides tools to generate the ice thickness from the bed topography along a palaeoglacier flowline applying the standard flow law for ice, and generates the 3D surface of the palaeoglacier using multiple interpolation methods. The toolbox performance has been evaluated using two extant glaciers, an icefield and a cirque/valley glacier from which the subglacial topography is known, using the basic reconstruction routine in GlaRe. Results in terms of ice surface, ice extent and equilibrium line altitude show excellent agreement that confirms the robustness of this procedure in the reconstruction of palaeoglaciers from glacial landforms such as frontal moraines.

  1. Dense 3D Reconstruction from High Frame-Rate Video Using a Static Grid Pattern.

    Science.gov (United States)

    Sagawa, Ryusuke; Furukawa, Ryo; Kawasaki, Hiroshi

    2014-09-01

    Dense 3D reconstruction of fast moving objects could contribute to various applications such as body structure analysis, accident avoidance, and so on. In this paper, we propose a technique based on a one-shot scanning method, which reconstructs 3D shapes for each frame of a high frame-rate video capturing the scenes projected by a static pattern. To avoid instability of image processing, we restrict the number of colors used in the pattern to less than two. The proposed technique comprises (1) an efficient algorithm to eliminate ambiguity of projected parallel-line patterns by using intersection points, (2) a batch reconstruction algorithm of multiple frames by using spatio-temporal constraints, and (3) an efficient detection method of color-encoded grid pattern based on de Bruijn sequence. In the experiments, the line detection algorithm worked effectively and the dense reconstruction algorithm produces accurate and robust results. We also show the improved results by using temporal constraints. Finally, the dense reconstructions of fast moving objects in a high frame-rate video are presented. PMID:26352228

  2. 3D tomographic reconstruction of coronary arteries using a precomputed 4D motion field

    International Nuclear Information System (INIS)

    In this paper, we present a new method to perform 3D tomographic reconstruction of coronary arteries from cone-beam rotational x-ray angiography acquisitions. We take advantage of the precomputation of the coronary artery motion, modelled as a parametric 4D motion field. Contrary to data gating or data triggering approaches, we homogeneously use all available frames, independently of the cardiac phase. In addition, we artificially subtract angiograms from their background structures. Our method significantly improves the reconstruction, by removing both motion and background artefacts. We have successfully tested it on the datasets from a synthetic phantom and 10 patients

  3. Combination of SANS and 3D stochastic reconstruction techniques for the study of nanostructured materials

    CERN Document Server

    Kikkinides, E S; Steriotis, T A; Kanellopoulos, N K; Mitropoulos, A C; Treimer, W

    2002-01-01

    Ceramic nanostructured materials have recently received scientific and industrial interest due to their unique properties. A series of such nanoporous structures were characterised by SANS techniques. The resulting scattering curves were analysed to obtain basic structural information regarding the pore size distribution and autocorrelation function of each material. Furthermore, stochastic reconstruction models were employed to generate 3D images with the same basic structural characteristics obtained from SANS. Finally, simulation results of permeation on the reconstructed images provide very good agreement with experimental data. (orig.)

  4. Improved 3D reconstruction in smart-room environments using ToF imaging

    DEFF Research Database (Denmark)

    Guðmundsson, Sigurjón Árni; Pardas, Montse; Casas, Josep R.;

    2010-01-01

    This paper presents the use of Time-of-Flight (ToF) cameras in smart-rooms and how this leads to improved results in segmenting the people in the room from the background and consequently better 3D reconstruction of foreground objects. A calibrated rig consisting of one Swissranger SR3100 Time......-of-Flight range camera and a high resolution standard CCD camera is set in a smart-room containing five other standard cameras. A probabilistic background model is used to segment each view and a shape from silhouette volume is reconstructed. It is shown that the presence of the range camera gives ways...

  5. Bayesian image reconstruction: Application to emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, J.; Llacer, J.

    1989-02-01

    In this paper we propose a Maximum a Posteriori (MAP) method of image reconstruction in the Bayesian framework for the Poisson noise case. We use entropy to define the prior probability and likelihood to define the conditional probability. The method uses sharpness parameters which can be theoretically computed or adjusted, allowing us to obtain MAP reconstructions without the problem of the grey'' reconstructions associated with the pre Bayesian reconstructions. We have developed several ways to solve the reconstruction problem and propose a new iterative algorithm which is stable, maintains positivity and converges to feasible images faster than the Maximum Likelihood Estimate method. We have successfully applied the new method to the case of Emission Tomography, both with simulated and real data. 41 refs., 4 figs., 1 tab.

  6. 3D water-vapor tomography with Shanghai GPS network to improve forecasted moisture field

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The vertical structure of water vapor in atmosphere is one of the initial information of numerical weather forecast model. Because of the strong variation of water vapor in atmosphere and limited spatio-temporal solutions of traditional observation technique, the initial water vapor field of numerical weather forecast model can not accurately be described. At present, using GPS slant observations to study water vapor profile is very popular in the world. Using slant water vapor(SWV) observations from Shanghai GPS network,we diagnose the three-dimensional(3D) water vapor structure over Shanghai area firstly in China. In water vapor tomography, Gauss weighted function is used as horizontal constraint, the output of numerical forecast is used as apriori information, and boundary condition is also considered. For the problem without exact apriori weights for observations, estimation of variance components is introduced firstly in water vapor tomography to determine posteriori weights. Robust estimation is chosen for reducing the effect of blunders on solutions. For the descending characteristic of water vapor with height increasing, non-equal weights are used along vertical direction. Comparisons between tomography results and the profile provided by numerical model (MM5) show that the forecasted moisture fields of MM5 can be improved obviously by GPS slant water vapor. Using GPS slant observations to study 3D structure of atmosphere in near real-time is very important for improving initial water vapor field of short-term weather forecast and enhancing the accuracy of numerical weather forecast.

  7. 3D RECONSTRUCTION AND ANALYSIS OF THE FRAGMENTED GRAINS IN A COMPOSITE MATERIAL

    Directory of Open Access Journals (Sweden)

    Luc Gillibert

    2013-06-01

    Full Text Available X-ray microtomography from solid propellant allows studying the microstructure of fragmented grains in damaged samples. A new reconstruction algorithm of fragmented grains for 3D images is introduced. Based on a watershed transform of a morphological closing of the input image, the algorithm can be used  with different sets of markers. Two of them are compared. After the grain reconstruction, a multiscale segmentation  algorithm is used to extract each fragment of the damaged grains. This allows an original quantitative study of the  fragmentation of each grain in 3D. Experimental results on X-ray microtomographic images of a solid propellant fragmented under compression are presented and validated.

  8. Order reconstruction phenomena and temperature-driven dynamics in a 3D zenithally bistable device

    KAUST Repository

    Raisch, A.

    2014-07-01

    We model the zenithally bistable device (ZBD) in three dimensions (3D), within the Landau-de Gennes theory, and find three stable static states in 3D without an applied field: the vertically aligned nematic (VAN) state, the hybrid aligned nematic (HAN) state and a third, high-tilt state, which we call the THAN state, with an interior and a surface defect. We recover the order reconstruction (OR) phenomenon around the defects in the HAN and THAN states and the 3D THAN and HAN solutions exhibit stable biaxial cylinders connecting defects on opposite faces of the ZBD device. We demonstrate a two-way temperature-driven switching between high-tilt and low-tilt states through controlled heating and cooling procedures in two dimensions (2D), with no applied fields. © CopyrightEPLA, 2014.

  9. 3D Indoor Building Environment Reconstruction using calibration of Range finder Data

    DEFF Research Database (Denmark)

    Jamali, Ali; Anton, François; Rahman, Alias Abdul;

    2015-01-01

    Nowadays, municipalities intend to have 3D city models for facility management, disaster management and architectural planning. 3D data acquisition can be done by laser scanning for indoor environment which is a costly and time consuming process. Currently, for indoor surveying, Electronic Distance...... Measurement (EDM) and Terrestrial Laser Scanner (TLS) are mostly used. In this paper, several techniques for indoor 3D building data acquisition have been investigated. For reducing the time and cost of indoor building data acquisition process, the Trimble LaserAce 1000 range finder is used. The accuracy...... of the rangefinder is evaluated and a simple spatial model is reconstructed from real data. This technique is rapid (it requires a shorter time as compared to others), but the results show inconsistencies in horizontal angles for short distances in indoor environments. The range finder was calibrated using a least...

  10. Renal Tumor Cryoablation Planning. The Efficiency of Simulation on Reconstructed 3D CT Scan

    Directory of Open Access Journals (Sweden)

    Ciprian Valerian LUCAN

    2010-12-01

    Full Text Available Introduction & Objective: Nephron-sparing surgical techniques risks are related to tumor relationships with adjacent anatomic structures. Complexity of the renal anatomy drives the interest to develop tools for 3D reconstruction and surgery simulation. The aim of the article was to assess the simulation on reconstructed 3D CT scan used for planning the cryoablation. Material & Method: A prospective randomized study was performed between Jan. 2007 and July 2009 on 27 patients who underwent retroperitoneoscopic T1a renal tumors cryoablation (RC. All patients were assessed preoperatively by CT scan, also used for 3D volume rendering. In the Gr.A, the patients underwent surgery planning by simulation on 3D CT scan. In the Gr.B., patients underwent standard RC. The two groups were compared in terms of surgical time, bleeding, postoperative drainage, analgesics requirement, hospital stay, time to socio-professional reintegration. Results: Fourteen patients underwent preoperative cryoablation planning (Gr.A and 13 patients underwent standard CR (Gr.B. All parameters analyzed were shorter in the Gr.A. On multivariate logistic regression, only shortens of the surgical time (138.79±5.51 min. in Gr.A. vs. 140.92±5.54 min in Gr.B. and bleeding (164.29±60.22 mL in Gr.A. vs. 215.38±100.80 mL in Gr.B. achieved statistical significance (p<0.05. The number of cryoneedles assessed by simulation had a 92.52% accuracy when compared with those effectively used. Conclusions: Simulation of the cryoablation using reconstructed 3D CT scan improves the surgical results. The application used for simulation was able to accurately assess the number of cryoneedles required for tumor ablation, their direction and approach.

  11. On the use of orientation filters for 3D reconstruction in event-driven stereo vision

    OpenAIRE

    Luis Alejandro eCamunas-Mesa; Teresa eSerrano-Gotarredona; Sio Hoi eIeng; Ryad Benjamin Benosman; Bernabe eLinares-Barranco

    2014-01-01

    The recently developed Dynamic Vision Sensors (DVS) sense visual information asynchronously and code it into trains of events with sub-micro second temporal resolution. This high temporal precision makes the output of these sensors especially suited for dynamic 3D visual reconstruction, by matching corresponding events generated by two different sensors in a stereo setup. This paper explores the use of Gabor filters to extract information about the orientation of the object edges that produce...

  12. 3D RECONSTRUCTION OF AN UNDERWATER ARCHAELOGICAL SITE: COMPARISON BETWEEN LOW COST CAMERAS

    Directory of Open Access Journals (Sweden)

    A. Capra

    2015-04-01

    Full Text Available The 3D reconstruction with a metric content of a submerged area, where objects and structures of archaeological interest are found, could play an important role in the research and study activities and even in the digitization of the cultural heritage. The reconstruction of 3D object, of interest for archaeologists, constitutes a starting point in the classification and description of object in digital format and for successive fruition by user after delivering through several media. The starting point is a metric evaluation of the site obtained with photogrammetric surveying and appropriate 3D restitution. The authors have been applying the underwater photogrammetric technique since several years using underwater digital cameras and, in this paper, digital low cost cameras (off-the-shelf. Results of tests made on submerged objects with three cameras are presented: © Canon Power Shot G12, © Intova Sport HD e © GoPro HERO 2. The experimentation had the goal to evaluate the precision in self-calibration procedures, essential for multimedia underwater photogrammetry, and to analyze the quality of 3D restitution. Precisions obtained in the calibration and orientation procedures was assessed by using three cameras, and an homogeneous set control points. Data were processed with © Agisoft Photoscan. Successively, 3D models were created and the comparison of the models derived from the use of different cameras was performed. Different potentialities of the used cameras are reported in the discussion section. The 3D restitution of objects and structures was integrated with sea bottom floor morphology in order to achieve a comprehensive description of the site. A possible methodology of survey and representation of submerged objects is therefore illustrated, considering an automatic and a semi-automatic approach.

  13. PCA-based 3D Shape Reconstruction of Human Foot Using Multiple Viewpoint Cameras

    Institute of Scientific and Technical Information of China (English)

    Edmée Amstutz; Tomoaki Teshima; Makoto Kimura; Masaaki Mochimaru; Hideo Saito

    2008-01-01

    This paper describes a multiple camera-based method to reconstruct the 3D shape of a human foot. From a foot database,an initial 3D model of the foot represented by a cloud of points is built. The shape parameters, which can characterize more than 92% of a foot, are defined by using the principal component analysis method. Then, using "active shape models", the initial 3D model is adapted to the real foot captured in multiple images by applying some constraints (edge points' distance and color variance). We insist here on the experiment part where we demonstrate the efficiency of the proposed method on a plastic foot model, and also on real human feet with various shapes. We propose and compare different ways of texturing the foot which is needed for reconstruction. We present an experiment performed on the plastic foot model and on human feet and propose two different ways to improve the final 3D shape's accuracy according to the previous experiments' results. The first improvement proposed is the densification of the cloud of points used to represent the initial model and the foot database. The second improvement concerns the projected patterns used to texture the foot. We conclude by showing the obtained results for a human foot with the average computed shape error being only 1.06mm.

  14. Comparison Between Two Generic 3d Building Reconstruction Approaches - Point Cloud Based VS. Image Processing Based

    Science.gov (United States)

    Dahlke, D.; Linkiewicz, M.

    2016-06-01

    This paper compares two generic approaches for the reconstruction of buildings. Synthesized and real oblique and vertical aerial imagery is transformed on the one hand into a dense photogrammetric 3D point cloud and on the other hand into photogrammetric 2.5D surface models depicting a scene from different cardinal directions. One approach evaluates the 3D point cloud statistically in order to extract the hull of structures, while the other approach makes use of salient line segments in 2.5D surface models, so that the hull of 3D structures can be recovered. With orders of magnitudes more analyzed 3D points, the point cloud based approach is an order of magnitude more accurate for the synthetic dataset compared to the lower dimensioned, but therefor orders of magnitude faster, image processing based approach. For real world data the difference in accuracy between both approaches is not significant anymore. In both cases the reconstructed polyhedra supply information about their inherent semantic and can be used for subsequent and more differentiated semantic annotations through exploitation of texture information.

  15. Sensor Fusion of Cameras and a Laser for City-Scale 3D Reconstruction

    Directory of Open Access Journals (Sweden)

    Yunsu Bok

    2014-11-01

    Full Text Available This paper presents a sensor fusion system of cameras and a 2D laser sensorfor large-scale 3D reconstruction. The proposed system is designed to capture data on afast-moving ground vehicle. The system consists of six cameras and one 2D laser sensor,and they are synchronized by a hardware trigger. Reconstruction of 3D structures is doneby estimating frame-by-frame motion and accumulating vertical laser scans, as in previousworks. However, our approach does not assume near 2D motion, but estimates free motion(including absolute scale in 3D space using both laser data and image features. In orderto avoid the degeneration associated with typical three-point algorithms, we present a newalgorithm that selects 3D points from two frames captured by multiple cameras. The problemof error accumulation is solved by loop closing, not by GPS. The experimental resultsshow that the estimated path is successfully overlaid on the satellite images, such that thereconstruction result is very accurate.

  16. Reconstruction Accuracy Assessment of Surface and Underwater 3D Motion Analysis: A New Approach

    Science.gov (United States)

    de Jesus, Kelly; de Jesus, Karla; Figueiredo, Pedro; Vilas-Boas, João Paulo; Fernandes, Ricardo Jorge; Machado, Leandro José

    2015-01-01

    This study assessed accuracy of surface and underwater 3D reconstruction of a calibration volume with and without homography. A calibration volume (6000 × 2000 × 2500 mm) with 236 markers (64 above and 88 underwater control points—with 8 common points at water surface—and 92 validation points) was positioned on a 25 m swimming pool and recorded with two surface and four underwater cameras. Planar homography estimation for each calibration plane was computed to perform image rectification. Direct linear transformation algorithm for 3D reconstruction was applied, using 1600000 different combinations of 32 and 44 points out of the 64 and 88 control points for surface and underwater markers (resp.). Root Mean Square (RMS) error with homography of control and validations points was lower than without it for surface and underwater cameras (P ≤ 0.03). With homography, RMS errors of control and validation points were similar between surface and underwater cameras (P ≥ 0.47). Without homography, RMS error of control points was greater for underwater than surface cameras (P ≤ 0.04) and the opposite was observed for validation points (P ≤ 0.04). It is recommended that future studies using 3D reconstruction should include homography to improve swimming movement analysis accuracy. PMID:26175796

  17. Reconstruction Accuracy Assessment of Surface and Underwater 3D Motion Analysis: A New Approach

    Directory of Open Access Journals (Sweden)

    Kelly de Jesus

    2015-01-01

    Full Text Available This study assessed accuracy of surface and underwater 3D reconstruction of a calibration volume with and without homography. A calibration volume (6000 × 2000 × 2500 mm with 236 markers (64 above and 88 underwater control points—with 8 common points at water surface—and 92 validation points was positioned on a 25 m swimming pool and recorded with two surface and four underwater cameras. Planar homography estimation for each calibration plane was computed to perform image rectification. Direct linear transformation algorithm for 3D reconstruction was applied, using 1600000 different combinations of 32 and 44 points out of the 64 and 88 control points for surface and underwater markers (resp.. Root Mean Square (RMS error with homography of control and validations points was lower than without it for surface and underwater cameras (P≤0.03. With homography, RMS errors of control and validation points were similar between surface and underwater cameras (P≥0.47. Without homography, RMS error of control points was greater for underwater than surface cameras (P≤0.04 and the opposite was observed for validation points (P≤0.04. It is recommended that future studies using 3D reconstruction should include homography to improve swimming movement analysis accuracy.

  18. Quality Analysis on 3d Buidling Models Reconstructed from Uav Imagery

    Science.gov (United States)

    Jarzabek-Rychard, M.; Karpina, M.

    2016-06-01

    Recent developments in UAV technology and structure from motion techniques have effected that UAVs are becoming standard platforms for 3D data collection. Because of their flexibility and ability to reach inaccessible urban parts, drones appear as optimal solution for urban applications. Building reconstruction from the data collected with UAV has the important potential to reduce labour cost for fast update of already reconstructed 3D cities. However, especially for updating of existing scenes derived from different sensors (e.g. airborne laser scanning), a proper quality assessment is necessary. The objective of this paper is thus to evaluate the potential of UAV imagery as an information source for automatic 3D building modeling at LOD2. The investigation process is conducted threefold: (1) comparing generated SfM point cloud to ALS data; (2) computing internal consistency measures of the reconstruction process; (3) analysing the deviation of Check Points identified on building roofs and measured with a tacheometer. In order to gain deep insight in the modeling performance, various quality indicators are computed and analysed. The assessment performed according to the ground truth shows that the building models acquired with UAV-photogrammetry have the accuracy of less than 18 cm for the plannimetric position and about 15 cm for the height component.

  19. Generic camera model and its calibration for computational integral imaging and 3D reconstruction.

    Science.gov (United States)

    Li, Weiming; Li, Youfu

    2011-03-01

    Integral imaging (II) is an important 3D imaging technology. To reconstruct 3D information of the viewed objects, modeling and calibrating the optical pickup process of II are necessary. This work focuses on the modeling and calibration of an II system consisting of a lenslet array, an imaging lens, and a charge-coupled device camera. Most existing work on such systems assumes a pinhole array model (PAM). In this work, we explore a generic camera model that accommodates more generality. This model is an empirical model based on measurements, and we constructed a setup for its calibration. Experimental results show a significant difference between the generic camera model and the PAM. Images of planar patterns and 3D objects were computationally reconstructed with the generic camera model. Compared with the images reconstructed using the PAM, the images present higher fidelity and preserve more high spatial frequency components. To the best of our knowledge, this is the first attempt in applying a generic camera model to an II system.

  20. Investigation of the quantitative accuracy of 3D iterative reconstruction algorithms in comparison to filtered back projection method: a phantom study

    Science.gov (United States)

    Abuhadi, Nouf; Bradley, David; Katarey, Dev; Podolyak, Zsolt; Sassi, Salem

    2014-03-01

    Introduction: Single-Photon Emission Computed Tomography (SPECT) is used to measure and quantify radiopharmaceutical distribution within the body. The accuracy of quantification depends on acquisition parameters and reconstruction algorithms. Until recently, most SPECT images were constructed using Filtered Back Projection techniques with no attenuation or scatter corrections. The introduction of 3-D Iterative Reconstruction algorithms with the availability of both computed tomography (CT)-based attenuation correction and scatter correction may provide for more accurate measurement of radiotracer bio-distribution. The effect of attenuation and scatter corrections on accuracy of SPECT measurements is well researched. It has been suggested that the combination of CT-based attenuation correction and scatter correction can allow for more accurate quantification of radiopharmaceutical distribution in SPECT studies (Bushberg et al., 2012). However, The effect of respiratory induced cardiac motion on SPECT images acquired using higher resolution algorithms such 3-D iterative reconstruction with attenuation and scatter corrections has not been investigated. Aims: To investigate the quantitative accuracy of 3D iterative reconstruction algorithms in comparison to filtered back projection (FBP) methods implemented on cardiac SPECT/CT imaging with and without CT-attenuation and scatter corrections. Also to investigate the effects of respiratory induced cardiac motion on myocardium perfusion quantification. Lastly, to present a comparison of spatial resolution for FBP and ordered subset expectation maximization (OSEM) Flash 3D together with and without respiratory induced motion, and with and without attenuation and scatter correction. Methods: This study was performed on a Siemens Symbia T16 SPECT/CT system using clinical acquisition protocols. Respiratory induced cardiac motion was simulated by imaging a cardiac phantom insert whilst moving it using a respiratory motion motor

  1. Modeling the Coast Mountains Batholith, British Columbia, Canada with 3D Seismic Tomography

    Science.gov (United States)

    Quinonez, S. M.; Olaya, J. C.; Miller, K. C.; Romero, R.; Velasco, A. A.; Harder, S. H.; Cerda, I.

    2011-12-01

    The Coast Mountains Batholith on the west coast of British Columbia, Canada comprises a series of granitic to tonalitic plutons; where felsic continental crust is generated from the subduction of mafic oceanic crust by partial melting and fractionation, leaving ultra-mafic roots. In July of 2009, a large controlled-source experiment was conducted along a 400km east - west transect from Bella Bella into central British Columbia. Student volunteers from multiple universities deployed 1,800 one-component and 200 three-component geophones plus 2400 Texan data recorders with 200-m spacing intervals and shot spacing at 30-km. The 18-point sources ranged from 160 to 1,000 kg of high explosive. The geoscience component of the NSF-funded Cyber-ShARE project at UTEP focuses on fusing models developed from different data sets to develop 3-D Earth models. Created in 2007, the Cyber-ShARE Center brings together experts in computer science, computational mathematics, education, earth science, and environmental science. We leverage the Cyber-ShARE work to implement an enhanced 3-D finite difference tomography approach for P-wave delays times (Hole, 1992) with a graphical user interface and visualization framework. In particular, to account for model sensitivity to picked P-wave arrival times, we use a model fusion approach (Ochoa et al., 2010) to generate a model with the lowest RMS residual that a combination of a set of Monte Carlo sample models. In order to make the seismic tomography process more interactive at many points, visualizations of model perturbation at each iteration will help to troubleshoot when a model is not converging to highlight where the RMS residual values are the highest to pinpoint where changes need to be made to achieve model convergence. Finally, a model of the upper mantle using 3-D P-wave tomography will be made to determine the location of these ultra-mafic roots.

  2. Parallelizable 3D statistical reconstruction for C-arm tomosynthesis system

    Science.gov (United States)

    Wang, Beilei; Barner, Kenneth; Lee, Denny

    2005-04-01

    Clinical diagnosis and security detection tasks increasingly require 3D information which is difficult or impossible to obtain from 2D (two dimensional) radiographs. As a 3D (three dimensional) radiographic and non-destructive imaging technique, digital tomosynthesis is especially fit for cases where 3D information is required while a complete projection data is not available. Nowadays, FBP (filtered back projection) is extensively used in industry for its fast speed and simplicity. However, it is hard to deal with situations where only a limited number of projections from constrained directions are available, or the SNR (signal to noises ratio) of the projections is low. In order to deal with noise and take into account a priori information of the object, a statistical image reconstruction method is described based on the acquisition model of X-ray projections. We formulate a ML (maximum likelihood) function for this model and develop an ordered-subsets iterative algorithm to estimate the unknown attenuation of the object. Simulations show that satisfied results can be obtained after 1 to 2 iterations, and after that there is no significant improvement of the image quality. An adaptive wiener filter is also applied to the reconstructed image to remove its noise. Some approximations to speed up the reconstruction computation are also considered. Applying this method to computer generated projections of a revised Shepp phantom and true projections from diagnostic radiographs of a patient"s hand and mammography images yields reconstructions with impressive quality. Parallel programming is also implemented and tested. The quality of the reconstructed object is conserved, while the computation time is considerably reduced by almost the number of threads used.

  3. Monitoring CO2 migration in a shallow sand aquifer using 3D crosshole electrical resistivity tomography

    OpenAIRE

    Yang, Xianjin; Lassen, Rune Nørbæk; Jensen, Karsten Høgh; Zibar, Majken Caroline Looms

    2015-01-01

    Three-dimensional (3D) crosshole electrical resistivity tomography (ERT) was used to monitor a pilot CO2 injection experiment at Vrøgum, western Denmark. The purpose was to evaluate the effectiveness of the ERT method for detection of small electrical conductivity (EC) changes during the first 2 days of CO2 injection in a shallow siliciclastic aquifer and to study the early-time behavior of a controlled small gaseous CO2 release. 45 kg of CO2 was injected over a 50-h period at 9.85 m depth. E...

  4. High-performance computational and geostatistical experiments for testing the capabilities of 3-d electrical tomography

    Energy Technology Data Exchange (ETDEWEB)

    Carle, S. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Daily, W. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Newmark, R. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramirez, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tompson, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    1999-01-19

    This project explores the feasibility of combining geologic insight, geostatistics, and high-performance computing to analyze the capabilities of 3-D electrical resistance tomography (ERT). Geostatistical methods are used to characterize the spatial variability of geologic facies that control sub-surface variability of permeability and electrical resistivity Synthetic ERT data sets are generated from geostatistical realizations of alluvial facies architecture. The synthetic data sets enable comparison of the "truth" to inversion results, quantification of the ability to detect particular facies at particular locations, and sensitivity studies on inversion parameters

  5. CT图像后处理重建膝关节三维模型:3D-CT评估前交叉韧带重建后的骨道差异%Reconstruction of three-dimensional models of knee joint using CT image post-processing technique:evaluation of bone tunnel difference after anterior cruciate ligament reconstruction using three-dimensional computed tomography

    Institute of Scientific and Technical Information of China (English)

    高冠奇; 张克远

    2015-01-01

    背景:有研究表明影响前交叉韧带重建手术效果的因素主要取决于骨道的位置,而目前对骨道位置的研究仍存在一定争议。目的:探讨3D-CT对关节镜辅助下前交叉韧带重建后骨道评估的临床价值。方法:对2014年1月至8月收治的58例前交叉韧带损伤患者行关节镜下前交叉韧带重建。股骨端采用Endobutton固定,胫骨端使用可吸收界面钉固定。分别对58个膝关节进行双源CT扫描,使用CT图像后处理工作站重建膝关节三维模型,再现股骨外髁内侧壁及重建后单束骨道,胫骨平台及骨道。根据Lysholm评分分级办法,将随访时Lysholm评分≥80分病例作为优良组,80分以下为不良组,标记、测量股骨及胫骨骨道中心点的相对位置,比较两者的位置关系。结果与结论:3D-CT 三维重建法清晰地反映了膝关节前交叉韧带重建后的骨道及其出入口的位置、固定物及移植物等情况。膝关节功能优良组与不良组患者的术侧膝关节的股骨骨道中心位置之间差异有显著性意义(P 0.05)。结果证实,3D-CT能够清晰重建骨隧道及前交叉韧带移植物的图像,临床上可用于评估骨隧道定位与移植物走形的关系。%BACKGROUND:Studies have shown that factors affecting the outcomes of anterior cruciate ligament reconstruction mainly depend on the position of bone tunnels. However, there stil exists certain controversy over the researches on the position of bone tunnels. OBJECTIVE:To investigate the clinical value of three-dimensional computed tomography on postoperative evaluation of bone tunnel after anterior cruciate ligament reconstruction under arthroscopic assistance. METHODS:Fifty-eight patients with anterior cruciate ligament injury who received the treatment from January 2014 to August 2014 underwent anterior cruciate ligament reconstruction under arthroscopic assistance. The femoral end was fixed using an

  6. Phase-retrieved optical projection tomography for 3D imaging through scattering layers

    Science.gov (United States)

    Ancora, Daniele; Di Battista, Diego; Giasafaki, Georgia; Psycharakis, Stylianos; Liapis, Evangelos; Zacharopoulos, Athanasios; Zacharakis, Giannis

    2016-03-01

    Recently great progress has been made in biological and biomedical imaging by combining non-invasive optical methods, novel adaptive light manipulation and computational techniques for intensity-based phase recovery and three dimensional image reconstruction. In particular and in relation to the work presented here, Optical Projection Tomography (OPT) is a well-established technique for imaging mostly transparent absorbing biological models such as C. Elegans and Danio Rerio. On the contrary, scattering layers like the cocoon surrounding the Drosophila during the pupae stage constitutes a challenge for three dimensional imaging through such a complex structure. However, recent studies enabled image reconstruction through scattering curtains up to few transport mean free paths via phase retrieval iterative algorithms allowing to uncover objects hidden behind complex layers. By combining these two techniques we explore the possibility to perform a three dimensional image reconstruction of fluorescent objects embedded between scattering layers without compromising its structural integrity. Dynamical cross correlation registration was implemented for the registration process due to translational and flipping ambiguity of the phase retrieval problem, in order to provide the correct aligned set of data to perform the back-projection reconstruction. We have thus managed to reconstruct a hidden complex object between static scattering curtains and compared with the effective reconstruction to fully understand the process before the in-vivo biological implementation.

  7. Measurement Matrix Optimization and Mismatch Problem Compensation for DLSLA 3-D SAR Cross-Track Reconstruction

    Science.gov (United States)

    Bao, Qian; Jiang, Chenglong; Lin, Yun; Tan, Weixian; Wang, Zhirui; Hong, Wen

    2016-01-01

    With a short linear array configured in the cross-track direction, downward looking sparse linear array three-dimensional synthetic aperture radar (DLSLA 3-D SAR) can obtain the 3-D image of an imaging scene. To improve the cross-track resolution, sparse recovery methods have been investigated in recent years. In the compressive sensing (CS) framework, the reconstruction performance depends on the property of measurement matrix. This paper concerns the technique to optimize the measurement matrix and deal with the mismatch problem of measurement matrix caused by the off-grid scatterers. In the model of cross-track reconstruction, the measurement matrix is mainly affected by the configuration of antenna phase centers (APC), thus, two mutual coherence based criteria are proposed to optimize the configuration of APCs. On the other hand, to compensate the mismatch problem of the measurement matrix, the sparse Bayesian inference based method is introduced into the cross-track reconstruction by jointly estimate the scatterers and the off-grid error. Experiments demonstrate the performance of the proposed APCs’ configuration schemes and the proposed cross-track reconstruction method. PMID:27556471

  8. 3D nanostructure reconstruction based on the SEM imaging principle, and applications

    International Nuclear Information System (INIS)

    This paper addresses a novel 3D reconstruction method for nanostructures based on the scanning electron microscopy (SEM) imaging principle. In this method, the shape from shading (SFS) technique is employed, to analyze the gray-scale information of a single top-view SEM image which contains all the visible surface information, and finally to reconstruct the 3D surface morphology. It offers not only unobstructed observation from various angles but also the exact physical dimensions of nanostructures. A convenient and commercially available tool (NanoViewer) is developed based on this method for nanostructure analysis and characterization of properties. The reconstruction result coincides well with the SEM nanostructure image and is verified in different ways. With the extracted structure information, subsequent research of the nanostructure can be carried out, such as roughness analysis, optimizing properties by structure improvement and performance simulation with a reconstruction model. Efficient, practical and non-destructive, the method will become a powerful tool for nanostructure surface observation and characterization. (paper)

  9. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  10. Measurement Matrix Optimization and Mismatch Problem Compensation for DLSLA 3-D SAR Cross-Track Reconstruction.

    Science.gov (United States)

    Bao, Qian; Jiang, Chenglong; Lin, Yun; Tan, Weixian; Wang, Zhirui; Hong, Wen

    2016-08-22

    With a short linear array configured in the cross-track direction, downward looking sparse linear array three-dimensional synthetic aperture radar (DLSLA 3-D SAR) can obtain the 3-D image of an imaging scene. To improve the cross-track resolution, sparse recovery methods have been investigated in recent years. In the compressive sensing (CS) framework, the reconstruction performance depends on the property of measurement matrix. This paper concerns the technique to optimize the measurement matrix and deal with the mismatch problem of measurement matrix caused by the off-grid scatterers. In the model of cross-track reconstruction, the measurement matrix is mainly affected by the configuration of antenna phase centers (APC), thus, two mutual coherence based criteria are proposed to optimize the configuration of APCs. On the other hand, to compensate the mismatch problem of the measurement matrix, the sparse Bayesian inference based method is introduced into the cross-track reconstruction by jointly estimate the scatterers and the off-grid error. Experiments demonstrate the performance of the proposed APCs' configuration schemes and the proposed cross-track reconstruction method.

  11. 3D Reconstruction of Interplanetary Scintillation (IPS) Remote-Sensing Data: Global Solar Wind Boundaries for Driving 3D-MHD Models

    Science.gov (United States)

    Yu, H.-S.; Jackson, B. V.; Hick, P. P.; Buffington, A.; Odstrcil, D.; Wu, C.-C.; Davies, J. A.; Bisi, M. M.; Tokumaru, M.

    2015-09-01

    The University of California, San Diego, time-dependent analyses of the heliosphere provide three-dimensional (3D) reconstructions of solar wind velocities and densities from observations of interplanetary scintillation (IPS). Using data from the Solar-Terrestrial Environment Laboratory, Japan, these reconstructions provide a real-time prediction of the global solar-wind density and velocity throughout the whole heliosphere with a temporal cadence of about one day (ips.ucsd.edu). Updates to this modeling effort continue: in the present article, near-Sun results extracted from the time-dependent 3D reconstruction are used as inner boundary conditions to drive 3D-MHD models ( e.g. ENLIL and H3D-MHD). This allows us to explore the differences between the IPS kinematic-model data-fitting procedure and current 3D-MHD modeling techniques. The differences in these techniques provide interesting insights into the physical principles governing the expulsion of coronal mass ejections (CMEs). Here we detail for the first time several specific CMEs and an induced shock that occurred in September 2011 that demonstrate some of the issues resulting from these analyses.

  12. 3D RECONSTRUCTION OF BUILDINGS WITH GABLED AND HIPPED STRUCTURES USING LIDAR DATA

    Directory of Open Access Journals (Sweden)

    H. Amini

    2014-10-01

    Full Text Available Buildings are the most important objects in urban areas. Thus, building detection using photogrammetry and remote sensing data as well as 3D model of buildings are very useful for many applications such as mobile navigation, tourism, and disaster management. In this paper, an approach has been proposed for detecting buildings by LiDAR data and aerial images, as well as reconstructing 3D model of buildings. In this regard, firstly, building detection carried out by utilizing a Supper Vector Machine (SVM as a supervise method. The supervise methods need training data that could be collected from some features. Hence, LiDAR data and aerial images were utilized to produce some features. The features were selected by considering their abilities for separating buildings from other objects. The evaluation results of building detection showed high accuracy and precision of the utilized approach. The detected buildings were labeled in order to reconstruct buildings, individually. Then the planes of each building were separated and adjacent planes were recognized to reduce the calculation volume and to increase the accuracy. Subsequently, the bottom planes of each building were detected in order to compute the corners of hipped roofs using intersection of three adjacent planes. Also, the corners of gabled roofs were computed by both calculating the intersection line of the adjacent planes and finding the intersection between the planes intersection line and their detected parcel. Finally, the coordinates of some nodes in building floor were computed and 3D model reconstruction was carried out. In order to evaluate the proposed method, 3D model of some buildings with different complexity level were generated. The evaluation results showed that the proposed method has reached credible performance.

  13. Ion track reconstruction in 3D using alumina-based fluorescent nuclear track detectors

    Science.gov (United States)

    Niklas, M.; Bartz, J. A.; Akselrod, M. S.; Abollahi, A.; Jäkel, O.; Greilich, S.

    2013-09-01

    Fluorescent nuclear track detectors (FNTDs) based on Al2O3: C, Mg single crystal combined with confocal microscopy provide 3D information on ion tracks with a resolution only limited by light diffraction. FNTDs are also ideal substrates to be coated with cells to engineer cell-fluorescent ion track hybrid detectors (Cell-Fit-HD). This radiobiological tool enables a novel platform linking cell responses to physical dose deposition on a sub-cellular level in proton and heavy ion therapies. To achieve spatial correlation between single ion hits in the cell coating and its biological response the ion traversals have to be reconstructed in 3D using the depth information gained by the FNTD read-out. FNTDs were coated with a confluent human lung adenocarcinoma epithelial (A549) cell layer. Carbon ion irradiation of the hybrid detector was performed perpendicular and angular to the detector surface. In situ imaging of the fluorescently labeled cell layer and the FNTD was performed in a sequential read-out. Making use of the trajectory information provided by the FNTD the accuracy of 3D track reconstruction of single particles traversing the hybrid detector was studied. The accuracy is strongly influenced by the irradiation angle and therefore by complexity of the FNTD signal. Perpendicular irradiation results in highest accuracy with error of smaller than 0.10°. The ability of FNTD technology to provide accurate 3D ion track reconstruction makes it a powerful tool for radiobiological investigations in clinical ion beams, either being used as a substrate to be coated with living tissue or being implanted in vivo.

  14. Sparse Image Reconstruction in Computed Tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer

    and limitations of sparse reconstruction methods in CT, in particular in a quantitative sense. For example, relations between image properties such as contrast, structure and sparsity, tolerable noise levels, suficient sampling levels, the choice of sparse reconstruction formulation and the achievable image...... quality remain unclear. This is a problem of high practical concern, because the large scale of CT problems makes detailed exploration of the parameter space very time-consuming. Due to the limited quantitative understanding, sparse reconstruction has not yet become the method of choice in practical CT......In recent years, increased focus on the potentially harmful effects of x-ray computed tomography (CT) scans, such as radiation-induced cancer, has motivated research on new low-dose imaging techniques. Sparse image reconstruction methods, as studied for instance in the field of compressed sensing...

  15. Real-time 3D computed tomographic reconstruction using commodity graphics hardware

    Science.gov (United States)

    Xu, Fang; Mueller, Klaus

    2007-07-01

    The recent emergence of various types of flat-panel x-ray detectors and C-arm gantries now enables the construction of novel imaging platforms for a wide variety of clinical applications. Many of these applications require interactive 3D image generation, which cannot be satisfied with inexpensive PC-based solutions using the CPU. We present a solution based on commodity graphics hardware (GPUs) to provide these capabilities. While GPUs have been employed for CT reconstruction before, our approach provides significant speedups by exploiting the various built-in hardwired graphics pipeline components for the most expensive CT reconstruction task, backprojection. We show that the timings so achieved are superior to those obtained when using the GPU merely as a multi-processor, without a drop in reconstruction quality. In addition, we also show how the data flow across the graphics pipeline can be optimized, by balancing the load among the pipeline components. The result is a novel streaming CT framework that conceptualizes the reconstruction process as a steady flow of data across a computing pipeline, updating the reconstruction result immediately after the projections have been acquired. Using a single PC equipped with a single high-end commodity graphics board (the Nvidia 8800 GTX), our system is able to process clinically-sized projection data at speeds meeting and exceeding the typical flat-panel detector data production rates, enabling throughput rates of 40-50 projections s-1 for the reconstruction of 5123 volumes.

  16. Real-time 3D computed tomographic reconstruction using commodity graphics hardware

    Energy Technology Data Exchange (ETDEWEB)

    Xu Fang; Mueller, Klaus [Center for Visual Computing, Computer Science Department, Stony Brook University, Stony Brook, NY 11794-4400 (United States)

    2007-07-21

    The recent emergence of various types of flat-panel x-ray detectors and C-arm gantries now enables the construction of novel imaging platforms for a wide variety of clinical applications. Many of these applications require interactive 3D image generation, which cannot be satisfied with inexpensive PC-based solutions using the CPU. We present a solution based on commodity graphics hardware (GPUs) to provide these capabilities. While GPUs have been employed for CT reconstruction before, our approach provides significant speedups by exploiting the various built-in hardwired graphics pipeline components for the most expensive CT reconstruction task, backprojection. We show that the timings so achieved are superior to those obtained when using the GPU merely as a multi-processor, without a drop in reconstruction quality. In addition, we also show how the data flow across the graphics pipeline can be optimized, by balancing the load among the pipeline components. The result is a novel streaming CT framework that conceptualizes the reconstruction process as a steady flow of data across a computing pipeline, updating the reconstruction result immediately after the projections have been acquired. Using a single PC equipped with a single high-end commodity graphics board (the Nvidia 8800 GTX), our system is able to process clinically-sized projection data at speeds meeting and exceeding the typical flat-panel detector data production rates, enabling throughput rates of 40-50 projections s{sup -1} for the reconstruction of 512{sup 3} volumes.

  17. Probabilistic fusion of angiographic and echographic images for the 3D reconstruction of vessels

    Science.gov (United States)

    Pellot-Barakat, Claire J. M.; Bloch, Isabelle; Sureda, Francisco; Herment, Alain; Sigelle, Marc; Horain, Patrick J.; Long, Anne

    1995-05-01

    In order to provide a better quantitative and morphologic description of complex vascular lesions, we propose an approach of 3D reconstruction of the vessel internal wall, based on data fusion from two different imaging sources: two x ray digital angiography projections and a stack of endovascular echography slices. After extraction of echographic and angiographic information to be fused, a geometric model leads to the determination of the unknown parameters which allow the alignment of all data in a common reference frame. Both types of data are then directly included in a probabilistic reconstruction process based on Markov random fields. The Markovian model consists of cost functions reflecting x ray and ultrasonic data consistency and regularization elements to control the anatomic reality of the reconstruction. The optimal solution according to the definition criteria is obtained by minimizing the model energy with an algorithm based on simulated annealing. Preliminary results have been obtained with data acquired on a dog aorta. The accuracy of reconstruction by data fusion is significantly improved compared with results obtained with separate reconstruction from angiographic or echographic data. Taking into account all information available about the problem, the method avoids uncertainties and ambiguities of a reconstruction based only on one modality, and the probabilistic fusion solves the possible contradictions between both acquisitions.

  18. A novel structured dictionary for fast processing of 3D medical images, with application to computed tomography restoration and denoising

    Science.gov (United States)

    Karimi, Davood; Ward, Rabab K.

    2016-03-01

    Sparse representation of signals in learned overcomplete dictionaries has proven to be a powerful tool with applications in denoising, restoration, compression, reconstruction, and more. Recent research has shown that learned overcomplete dictionaries can lead to better results than analytical dictionaries such as wavelets in almost all image processing applications. However, a major disadvantage of these dictionaries is that their learning and usage is very computationally intensive. In particular, finding the sparse representation of a signal in these dictionaries requires solving an optimization problem that leads to very long computational times, especially in 3D image processing. Moreover, the sparse representation found by greedy algorithms is usually sub-optimal. In this paper, we propose a novel two-level dictionary structure that improves the performance and the speed of standard greedy sparse coding methods. The first (i.e., the top) level in our dictionary is a fixed orthonormal basis, whereas the second level includes the atoms that are learned from the training data. We explain how such a dictionary can be learned from the training data and how the sparse representation of a new signal in this dictionary can be computed. As an application, we use the proposed dictionary structure for removing the noise and artifacts in 3D computed tomography (CT) images. Our experiments with real CT images show that the proposed method achieves results that are comparable with standard dictionary-based methods while substantially reducing the computational time.

  19. 3D INDOOR BUILDING ENVIRONMENT RECONSTRUCTION USING CALIBRATION OF RANGEFINDER DATA

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2015-10-01

    Full Text Available Nowadays, municipalities intend to have 3D city models for facility management, disaster management and architectural planning. 3D data acquisition can be done by laser scanning for indoor environment which is a costly and time consuming process. Currently, for indoor surveying, Electronic Distance Measurement (EDM and Terrestrial Laser Scanner (TLS are mostly used. In this paper, several techniques for indoor 3D building data acquisition have been investigated. For reducing the time and cost of indoor building data acquisition process, the Trimble LaserAce 1000 range finder is used. The accuracy of the rangefinder is evaluated and a simple spatial model is reconstructed from real data. This technique is rapid (it requires a shorter time as compared to others, but the results show inconsistencies in horizontal angles for short distances in indoor environments. The range finder was calibrated using a least square adjustment algorithm. To control the uncertainty of the calibration and of the reconstruction of the building from the measurements, interval analysis and homotopy continuation are used.

  20. Implementation of a fast running full core pin power reconstruction method in DYN3D

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Torres, Armando Miguel [Instituto Nacional de Investigaciones Nucleares, Department of Nuclear Systems, Carretera Mexico – Toluca s/n, La Marquesa, 52750 Ocoyoacac (Mexico); Sanchez-Espinoza, Victor Hugo, E-mail: victor.sanchez@kit.edu [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology, Hermann-vom-Helmhotz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Kliem, Sören; Gommlich, Andre [Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328 Dresden (Germany)

    2014-07-01

    Highlights: • New pin power reconstruction (PPR) method for the nodal diffusion code DYN3D. • Flexible PPR method applicable to a single, a group or to all fuel assemblies (square, hex). • Combination of nodal with pin-wise solutions (non-conform geometry). • PPR capabilities shown for REA of a Minicore (REA) PWR whole core. - Abstract: This paper presents a substantial extension of the pin power reconstruction (PPR) method used in the reactor dynamics code DYN3D with the aim to better describe the heterogeneity within the fuel assembly during reactor simulations. The flexibility of the new implemented PPR permits the local spatial refinement of one fuel assembly, of a cluster of fuel assemblies, of a quarter or eight of a core or even of a whole core. The application of PPR in core regions of interest will pave the way for the coupling with sub-channel codes enabling the prediction of local safety parameters. One of the main advantages of considering regions and not only a hot fuel assembly (FA) is the fact that the cross flow within this region can be taken into account by the subchannel code. The implementation of the new PPR method has been tested analysing a rod ejection accident (REA) in a PWR minicore consisting of 3 × 3 FA. Finally, the new capabilities of DNY3D are demonstrated by the analysing a boron dilution transient in a PWR MOX core and the pin power of a VVER-1000 reactor at stationary conditions.

  1. Implementation of a fast running full core pin power reconstruction method in DYN3D

    International Nuclear Information System (INIS)

    Highlights: • New pin power reconstruction (PPR) method for the nodal diffusion code DYN3D. • Flexible PPR method applicable to a single, a group or to all fuel assemblies (square, hex). • Combination of nodal with pin-wise solutions (non-conform geometry). • PPR capabilities shown for REA of a Minicore (REA) PWR whole core. - Abstract: This paper presents a substantial extension of the pin power reconstruction (PPR) method used in the reactor dynamics code DYN3D with the aim to better describe the heterogeneity within the fuel assembly during reactor simulations. The flexibility of the new implemented PPR permits the local spatial refinement of one fuel assembly, of a cluster of fuel assemblies, of a quarter or eight of a core or even of a whole core. The application of PPR in core regions of interest will pave the way for the coupling with sub-channel codes enabling the prediction of local safety parameters. One of the main advantages of considering regions and not only a hot fuel assembly (FA) is the fact that the cross flow within this region can be taken into account by the subchannel code. The implementation of the new PPR method has been tested analysing a rod ejection accident (REA) in a PWR minicore consisting of 3 × 3 FA. Finally, the new capabilities of DNY3D are demonstrated by the analysing a boron dilution transient in a PWR MOX core and the pin power of a VVER-1000 reactor at stationary conditions

  2. Custom Anatomical 3D Spacer for Temporomandibular Joint Resection and Reconstruction.

    Science.gov (United States)

    Green, John Marshall; Lawson, Sarah T; Liacouras, Peter C; Wise, Edward M; Gentile, Michael A; Grant, Gerald Thomas

    2016-03-01

    Two cases are presented using a two-stage approach and a custom antibiotic spacer placement. Temporomandibular reconstruction can be very demanding and accomplished with a variety of methods in preparation of a total joint and ramus reconstruction with total joint prostheses (TMJ Concepts, Ventura, CA). Three-dimensional reconstructions from diagnostic computed tomography were used to establish a virtually planned resection which included the entire condyle-ramus complex. From these data, digital designs were used to manufacture molds to facilitate intraoperative fabrication of precise custom anatomic spacers from rapidly setting antibiotic-impregnated polymethyl methacrylate. Molds were manufactured using vat polymerization (stereolithography) with a photopolymer in the first case and powder bed fusion (electron beam melting) with Ti6AL4V for the second. Surgical methodology and the use of molds for intraoperative spacer fabrication for each case are discussed. PMID:26889353

  3. High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid

    Directory of Open Access Journals (Sweden)

    J. Cabello

    2012-01-01

    Full Text Available Statistical iterative methods are a widely used method of image reconstruction in emission tomography. Traditionally, the image space is modelled as a combination of cubic voxels as a matter of simplicity. After reconstruction, images are routinely filtered to reduce statistical noise at the cost of spatial resolution degradation. An alternative to produce lower noise during reconstruction is to model the image space with spherical basis functions. These basis functions overlap in space producing a significantly large number of non-zero elements in the system response matrix (SRM to store, which additionally leads to long reconstruction times. These two problems are partly overcome by exploiting spherical symmetries, although computation time is still slower compared to non-overlapping basis functions. In this work, we have implemented the reconstruction algorithm using Graphical Processing Unit (GPU technology for speed and a precomputed Monte-Carlo-calculated SRM for accuracy. The reconstruction time achieved using spherical basis functions on a GPU was 4.3 times faster than the Central Processing Unit (CPU and 2.5 times faster than a CPU-multi-core parallel implementation using eight cores. Overwriting hazards are minimized by combining a random line of response ordering and constrained atomic writing. Small differences in image quality were observed between implementations.

  4. Bone histomorphometric quantification by X-ray phase contrast and transmission 3D SR microcomputed tomography

    International Nuclear Information System (INIS)

    Full text: Conventional histomorphometry is an important method for quantitative evaluation of bone microstructure. X-ray computed tomography is a noninvasive technique, which can be used to evaluate histomorphometric indices. In this technique, the output 3D images are used to quantify the whole sample, differently from the conventional one, in which the quantification is performed in 2D slices and extrapolated for 3D case. Looking for better resolutions and visualization of soft tissues, X-ray phase contrast imaging technique was developed. The objective of this work was to perform histomorphometric quantification of human cancellous bone using 3D synchrotron X ray computed microtomography, using two distinct techniques: transmission and phase contrast, in order to compare the results and evaluate the viability of applying the same methodology of quantification for both technique. All experiments were performed at the ELETTRA Synchrotron Light Laboratory in Trieste (Italy). MicroCT data sets were collected using the CT set-up on the SYRMEP (Synchrotron Radiation for Medical Physics) beamline. Results showed that there is a better correlation between histomorphometric parameters of both techniques when morphological filters had been used. However, using these filters, some important information given by phase contrast are lost and they shall be explored by new techniques of quantification

  5. Testing & Validating: 3D Seismic Travel Time Tomography (Detailed Shallow Subsurface Imaging)

    Science.gov (United States)

    Marti, David; Marzan, Ignacio; Alvarez-Marron, Joaquina; Carbonell, Ramon

    2016-04-01

    A detailed full 3 dimensional P wave seismic velocity model was constrained by a high-resolution seismic tomography experiment. A regular and dense grid of shots and receivers was use to image a 500x500x200 m volume of the shallow subsurface. 10 GEODE's resulting in a 240 channels recording system and a 250 kg weight drop were used for the acquisition. The recording geometry consisted in 10x20m geophone grid spacing, and a 20x20 m stagered source spacing. A total of 1200 receivers and 676 source points. The study area is located within the Iberian Meseta, in Villar de Cañas (Cuenca, Spain). The lithological/geological target consisted in a Neogen sedimentary sequence formed from bottom to top by a transition from gyspum to silstones. The main objectives consisted in resolving the underground structure: contacts/discontinuities; constrain the 3D geometry of the lithology (possible cavities, faults/fractures). These targets were achieved by mapping the 3D distribution of the physical properties (P-wave velocity). The regularly space dense acquisition grid forced to acquire the survey in different stages and with a variety of weather conditions. Therefore, a careful quality control was required. More than a half million first arrivals were inverted to provide a 3D Vp velocity model that reached depths of 120 m in the areas with the highest ray coverage. An extended borehole campaign, that included borehole geophysical measurements in some wells provided unique tight constraints on the lithology an a validation scheme for the tomographic results. The final image reveals a laterally variable structure consisting of four different lithological units. In this methodological validation test travel-time tomography features a high capacity of imaging in detail the lithological contrasts for complex structures located at very shallow depths.

  6. Automated 3D Scenes Reconstruction Using Multiple Stereo Pairs from Portable Four-Camera Photographic Measurement System

    Directory of Open Access Journals (Sweden)

    Qi Peng

    2015-01-01

    Full Text Available An effective automatic 3D reconstruction method using a portable four-camera photographic measurement system (PFCPMS is proposed. By taking advantage of the complementary stereo information from four cameras, a fast and highly accurate feature point matching algorithm is developed for 3D reconstruction. Specifically, we first utilize a projection method to obtain a large number of dense feature points. And then a reduction and clustering treatment is applied to simplify the Delaunay triangulation process and reconstruct a 3D model for each scene. In addition, a 3D model stitching approach is proposed to further improve the performance of the limited field-of-view for image-based method. The experimental results tested on the 172 cave in Mogao Grottoes indicate that the proposed method is effective to reconstruct a 3D scene with a low-cost four-camera photographic measurement system.

  7. Compressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.

    Science.gov (United States)

    Nam, Seunghoon; Akçakaya, Mehmet; Basha, Tamer; Stehning, Christian; Manning, Warren J; Tarokh, Vahid; Nezafat, Reza

    2013-01-01

    A disadvantage of three-dimensional (3D) isotropic acquisition in whole-heart coronary MRI is the prolonged data acquisition time. Isotropic 3D radial trajectories allow undersampling of k-space data in all three spatial dimensions, enabling accelerated acquisition of the volumetric data. Compressed sensing (CS) reconstruction can provide further acceleration in the acquisition by removing the incoherent artifacts due to undersampling and improving the image quality. However, the heavy computational overhead of the CS reconstruction has been a limiting factor for its application. In this article, a parallelized implementation of an iterative CS reconstruction method for 3D radial acquisitions using a commercial graphics processing unit is presented. The execution time of the graphics processing unit-implemented CS reconstruction was compared with that of the C++ implementation, and the efficacy of the undersampled 3D radial acquisition with CS reconstruction was investigated in both phantom and whole-heart coronary data sets. Subsequently, the efficacy of CS in suppressing streaking artifacts in 3D whole-heart coronary MRI with 3D radial imaging and its convergence properties were studied. The CS reconstruction provides improved image quality (in terms of vessel sharpness and suppression of noise-like artifacts) compared with the conventional 3D gridding algorithm, and the graphics processing unit implementation greatly reduces the execution time of CS reconstruction yielding 34-54 times speed-up compared with C++ implementation. PMID:22392604

  8. 3-D analysis of dictyosomes and multivesicular bodies in the green alga Micrasterias denticulata by FIB/SEM tomography.

    Science.gov (United States)

    Wanner, Gerhard; Schäfer, Tillman; Lütz-Meindl, Ursula

    2013-11-01

    In the present study we employ FIB/SEM tomography for analyzing 3-D architecture of dictyosomes and formation of multivesicular bodies (MVB) in high pressure frozen and cryo-substituted interphase cells of the green algal model system Micrasterias denticulata. The ability of FIB/SEM of milling very thin 'slices' (5-10 nm), viewing the block face and of capturing cytoplasmic volumes of several hundred μm(3) provides new insight into the close spatial connection of the ER-Golgi machinery in an algal cell particularly in z-direction, complementary to informations obtained by TEM serial sectioning or electron tomography. Our FIB/SEM series and 3-D reconstructions show that interphase dictyosomes of Micrasterias are not only closely associated to an ER system at their cis-side which is common in various plant cells, but are surrounded by a huge "trans-ER" sheath leading to an almost complete enwrapping of dictyosomes by the ER. This is particularly interesting as the presence of a trans-dictyosomal ER system is well known from mammalian secretory cells but not from cells of higher plants to which the alga Micrasterias is closely related. In contrast to findings in plant storage tissue indicating that MVBs originate from the trans-Golgi network or its derivatives our investigations show that MVBs in Micrasterias are in direct spatial contact with both, trans-Golgi cisternae and the trans-ER sheath which provides evidence that both endomembrane compartments are involved in their formation. PMID:24135121

  9. Calibration target reconstruction for 3-D vision inspection system of large-scale engineering objects

    Science.gov (United States)

    Yin, Yongkai; Peng, Xiang; Guan, Yingjian; Liu, Xiaoli; Li, Ameng

    2010-11-01

    It is usually difficult to calibrate the 3-D vision inspection system that may be employed to measure the large-scale engineering objects. One of the challenges is how to in-situ build-up a large and precise calibration target. In this paper, we present a calibration target reconstruction strategy to solve such a problem. First, we choose one of the engineering objects to be inspected as a calibration target, on which we paste coded marks on the object surface. Next, we locate and decode marks to get homologous points. From multiple camera images, the fundamental matrix between adjacent images can be estimated, and then the essential matrix can be derived with priori known camera intrinsic parameters and decomposed to obtain camera extrinsic parameters. Finally, we are able to obtain the initial 3D coordinates with binocular stereo vision reconstruction, and then optimize them with the bundle adjustment by considering the lens distortions, leading to a high-precision calibration target. This reconstruction strategy has been applied to the inspection of an industrial project, from which the proposed method is successfully validated.

  10. Volumetric Next-best-view Planning for 3D Object Reconstruction with Positioning Error

    Directory of Open Access Journals (Sweden)

    J. Irving Vasquez-Gomez

    2014-10-01

    Full Text Available Three-dimensional (3D object reconstruction is the process of building a 3D model of a real object. This task is performed by taking several scans of an object from different locations (views. Due to the limited field of view of the sensor and the object’s self-occlusions, it is a difficult problem to solve. In addition, sensor positioning by robots is not perfect, making the actual view different from the expected one. We propose a next best view (NBV algorithm that determines each view to reconstruct an arbitrary object. Furthermore, we propose a method to deal with the uncertainty in sensor positioning. The algorithm fulfills all the constraints of a reconstruction process, such as new information, positioning constraints, sensing constraints and registration constraints. Moreover, it improves the scan’s quality and reduces the navigation distance. The algorithm is based on a search-based paradigm where a set of candidate views is generated and then each candidate view is evaluated to determine which one is the best. To deal with positioning uncertainty, we propose a second stage which re-evaluates the views according to their neighbours, such that the best view is that which is within a region of the good views. The results of simulation and comparisons with previous approaches are presented.

  11. 3D reconstruction in PET cameras with irregular sampling and depth of interaction

    International Nuclear Information System (INIS)

    We present 3D reconstruction algorithms that address fully 3D tomographic reconstruction using septa-less, stationary, and rectangular cameras. The field of view (FOV) encompasses the entire volume enclosed by detector modules capable of measuring depth of interaction (DOI). The Filtered Backprojection based algorithms incorporate DOI, accommodate irregular sampling, and minimize interpolation in the data by defining lines of response between the measured interaction points. We use fixed-width, evenly spaced radial bins in order to use the FFT, but use irregular angular sampling to minimize the number of unnormalizable zero efficiency sinogram bins. To address persisting low efficiency bins, we perform 2D nearest neighbor radial smoothing, employ a semi-iterative procedure to estimate the unsampled data, and mash the ''in plane'' and the first oblique projections to reconstruct the 2D image in the 3DRP algorithm. We present artifact free, essentially spatially isotropic images of Monte Carlo data with FWHM resolutions o 1.50 mm. 2.25 mm, and 3.00 mm at the center, in the bulk, and at the edges and corners of the FOV respectively

  12. Geometric reconstruction methods for electron tomography

    Energy Technology Data Exchange (ETDEWEB)

    Alpers, Andreas, E-mail: alpers@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Gardner, Richard J., E-mail: Richard.Gardner@wwu.edu [Department of Mathematics, Western Washington University, Bellingham, WA 98225-9063 (United States); König, Stefan, E-mail: koenig@ma.tum.de [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany); Pennington, Robert S., E-mail: robert.pennington@uni-ulm.de [Center for Electron Nanoscopy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Boothroyd, Chris B., E-mail: ChrisBoothroyd@cantab.net [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Houben, Lothar, E-mail: l.houben@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Dunin-Borkowski, Rafal E., E-mail: rdb@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute, Forschungszentrum Jülich, D-52425 Jülich (Germany); Joost Batenburg, Kees, E-mail: Joost.Batenburg@cwi.nl [Centrum Wiskunde and Informatica, NL-1098XG, Amsterdam, The Netherlands and Vision Lab, Department of Physics, University of Antwerp, B-2610 Wilrijk (Belgium)

    2013-05-15

    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and non-linear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180° tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire. - Highlights: ► Four algorithms for electron tomography are introduced that utilize prior knowledge. ► Objects are assumed to be homogeneous; convexity and regularity is also discussed. ► We are able to reconstruct slices of a nanowire from as few as four projections. ► Algorithms should be selected based on the specific reconstruction task at hand.

  13. Quantitative roughness characterization and 3D reconstruction of electrode surface using cyclic voltammetry and SEM image

    Energy Technology Data Exchange (ETDEWEB)

    Dhillon, Shweta; Kant, Rama, E-mail: rkant@chemistry.du.ac.in

    2013-10-01

    Area measurements from cyclic voltammetry (CV) and image from scanning electron microscopy (SEM) are used to characterize electrode statistical morphology, 3D surface reconstruction and its electroactivity. SEM images of single phased materials correspond to two-dimensional (2D) projections of 3D structures, leading to an incomplete characterization. Lack of third dimension information in SEM image is circumvented using equivalence between denoised SEM image and CV area measurements. This CV-SEM method can be used to estimate power spectral density (PSD), width, gradient, finite fractal nature of roughness and local morphology of the electrode. We show that the surface morphological statistical property like distribution function of gradient can be related to local electro-activity. Electrode surface gradient micrographs generated here can provide map of electro-activity sites. Finally, the densely and uniformly packed small gradient over the Pt-surface is the determining criterion for high intrinsic electrode activity.

  14. 3D tracking the Brownian motion of colloidal particles using digital holographic microscopy and joint reconstruction

    CERN Document Server

    Verrier, Nicolas; Fournel, Thierry

    2015-01-01

    In-line digital holography is a valuable tool for sizing, locating and tracking micro- or nano-objects in a volume. When a parametric imaging model is available, Inverse Problems approaches provide a straightforward estimate of the object parameters by fitting data with the model, thereby allowing accurate reconstruction. As recently proposed and demonstrated, combining pixel super-resolution techniques with Inverse Problems approaches improves the estimation of particle size and 3D-position. Here we demonstrate the accurate tracking of colloidal particles in Brownian motion. Particle size and 3D-position are jointly optimized from video holograms acquired with a digital holographic microscopy set up based on a "low-end" microscope objective ($\\times 20$, $\\rm NA\\ 0.5$). Exploiting information redundancy makes it possible to characterize particles with a standard deviation of 15 nm in size and a theoretical resolution of 2 x 2 x 5 nm$^3$ for position under additive white Gaussian noise assumption.

  15. 3D Reconstruction of Coronal Loops by the Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Erwin Verwichte

    2013-10-01

    Full Text Available Knowing the three dimensional structure of plasma filaments in the uppermost part of the solar atmosphere, known as coronal loops, and especially their length, is an important parameter in the wave-based diagnostics of this part of the Sun. The combination of observations of the Sun from different points of observations in space, thanks to the most recent missions, including the Solar Dynamics Observatory (SDO and the Solar TErrestrial RElations Observatory (STEREO, allows us to infer information about the geometrical shape of coronal loops in 3D space. Here, we propose a new method to reconstruct the loop shape starting from stereoscopically determined 3D points, which sample the loop length, by principal component analysis. This method is shown to retrieve in an easy way the main parameters that define the loop, e.g., the minor and major axes, the loop plane, the azimuthal and inclination angles, for the special case of a coplanar loop.

  16. New Virtual Cutting Algorithms for 3D Surface Model Reconstructed from Medical Images

    Institute of Scientific and Technical Information of China (English)

    WANG Wei-hong; QIN Xu-Jia

    2006-01-01

    This paper proposes a practical algorithms of plane cutting, stereo clipping and arbitrary cutting for 3D surface model reconstructed from medical images. In plane cutting and stereo clipping algorithms, the 3D model is cut by plane or polyhedron. Lists of edge and vertex in every cut plane are established. From these lists the boundary contours are created and their relationship of embrace is ascertained. The region closed by the contours is triangulated using Delaunay triangulation algorithm. Arbitrary cutting operation creates cutting curve interactively.The cut model still maintains its correct topology structure. With these operations,tissues inside can be observed easily and it can aid doctors to diagnose. The methods can also be used in surgery planning of radiotherapy.

  17. 3D reconstruction in laparoscopy with close-range photometric stereo.

    Science.gov (United States)

    Collins, Toby; Bartoli, Adrien

    2012-01-01

    In this paper we present the first solution to 3D reconstruction in monocular laparoscopy using methods based on Photometric Stereo (PS). Our main contributions are to provide the new theory and practical solutions to successfully apply PS in close-range imaging conditions. We are specifically motivated by a solution with minimal hardware modification to existing laparoscopes. In fact the only physical modification we make is to adjust the colour of the laparoscope's illumination via three colour filters placed at its tip. Once calibrated, our approach can compute 3D from a single image, does not require correspondence estimation, and computes absolute depth densely. We demonstrate the potential of our approach with ground truth ex-vivo and in-vivo experimentation. PMID:23286102

  18. 3D reconstruction of hollow parts analyzing images acquired by a fiberscope

    International Nuclear Information System (INIS)

    A modified fiberscope used to reconstruct difficult-to-reach inner structures is presented. By substituting the fiberscope’s original illumination system, we can project a profile-revealing light line inside the object of study. The light line is obtained using a sandwiched power light-emitting diode (LED) attached to an extension arm on the tip of the fiberscope. Profile images from the interior of the object are then captured by a camera attached to the fiberscope’s eyepiece. Using a series of those images at different positions, the system is capable of generating a 3D reconstruction of the object with submillimeter accuracy. Also proposed is the use of a combination of known filters to remove the honeycomb structures produced by the fiberscope and the use of ring gages to obtain the extrinsic parameters of the camera attached to the fiberscope and the metrological traceability of the system. Several standard ring diameter measurements were compared against their certified values to improve the accuracy of the system. To exemplify an application, a 3D reconstruction of the interior of a refrigerator duct was conducted. This reconstruction includes accuracy assessment by comparing the measurements of the system to a coordinate measuring machine. The system, as described, is capable of 3D reconstruction of the interior of objects with uniform and non-uniform profiles from 10 to 60 mm in transversal dimensions and a depth of 1000 mm if the material of the walls of the object is translucent and allows the detection of the power LED light from the exterior through the wall. If this is not possible, we propose the use of a magnetic scale which reduces the working depth to 170 mm. The assessed accuracy is around ±0.15 mm in 2D cross-section reconstructions and ±1.3 mm in 1D position using a magnetic scale, and ±0.5 mm using a CCD camera. (paper)

  19. Grammar-Supported 3d Indoor Reconstruction from Point Clouds for As-Built Bim

    Science.gov (United States)

    Becker, S.; Peter, M.; Fritsch, D.

    2015-03-01

    The paper presents a grammar-based approach for the robust automatic reconstruction of 3D interiors from raw point clouds. The core of the approach is a 3D indoor grammar which is an extension of our previously published grammar concept for the modeling of 2D floor plans. The grammar allows for the modeling of buildings whose horizontal, continuous floors are traversed by hallways providing access to the rooms as it is the case for most office buildings or public buildings like schools, hospitals or hotels. The grammar is designed in such way that it can be embedded in an iterative automatic learning process providing a seamless transition from LOD3 to LOD4 building models. Starting from an initial low-level grammar, automatically derived from the window representations of an available LOD3 building model, hypotheses about indoor geometries can be generated. The hypothesized indoor geometries are checked against observation data - here 3D point clouds - collected in the interior of the building. The verified and accepted geometries form the basis for an automatic update of the initial grammar. By this, the knowledge content of the initial grammar is enriched, leading to a grammar with increased quality. This higher-level grammar can then be applied to predict realistic geometries to building parts where only sparse observation data are available. Thus, our approach allows for the robust generation of complete 3D indoor models whose quality can be improved continuously as soon as new observation data are fed into the grammar-based reconstruction process. The feasibility of our approach is demonstrated based on a real-world example.

  20. TReMAP: Automatic 3D Neuron Reconstruction Based on Tracing, Reverse Mapping and Assembling of 2D Projections.

    Science.gov (United States)

    Zhou, Zhi; Liu, Xiaoxiao; Long, Brian; Peng, Hanchuan

    2016-01-01

    Efficient and accurate digital reconstruction of neurons from large-scale 3D microscopic images remains a challenge in neuroscience. We propose a new automatic 3D neuron reconstruction algorithm, TReMAP, which utilizes 3D Virtual Finger (a reverse-mapping technique) to detect 3D neuron structures based on tracing results on 2D projection planes. Our fully automatic tracing strategy achieves close performance with the state-of-the-art neuron tracing algorithms, with the crucial advantage of efficient computation (much less memory consumption and parallel computation) for large-scale images.

  1. Fast 3D-EM reconstruction using Planograms for stationary planar positron emission mammography camera.

    Science.gov (United States)

    Motta, A; Guerra, A Del; Belcari, N; Moehrs, S; Panetta, D; Righi, S; Valentini, D

    2005-12-01

    At the University of Pisa we are building a PEM prototype, the YAP-PEM camera, consisting of two opposite 6 x 6 x 3 cm3 detector heads of 30 x 30 YAP:Ce finger crystals, 2 x 2 x 30 mm3 each. The camera will be equipped with breast compressors. The acquisition will be stationary. Compared with a whole body PET scanner, a planar Positron Emission Mammography (PEM) camera allows a better, easier and more flexible positioning around the breast in the vicinity of the tumor: this increases the sensitivity and solid angle coverage, and reduces cost. To avoid software rejection of data during the reconstruction, resulting in a reduced sensitivity, we adopted a 3D-EM reconstruction which uses all of the collected Lines Of Response (LORs). This skips the PSF distortion given by data rebinning procedures and/or Fourier methods. The traditional 3D-EM reconstruction requires several times the computation of the LOR-voxel correlation matrix, or probability matrix {p(ij)}; therefore is highly time-consuming. We use the sparse and symmetry properties of the matrix {p(ij)} to perform fast 3D-EM reconstruction. Geometrically, a 3D grid of cubic voxels (FOV) is crossed by several divergent 3D line sets (LORs). The symmetries occur when tracing different LORs produces the same p(ij) value. Parallel LORs of different sets cross the FOV in the same way, and the repetition of p(ij) values depends on the ratio between the tube and voxel sizes. By optimizing this ratio, the occurrence of symmetries is increased. We identify a nucleus of symmetry of LORs: for each set of symmetrical LORs we choose just one LOR to be put in the nucleus, while the others lie outside. All of the possible p(ij) values are obtainable by tracking only the LORs of this nucleus. The coordinates of the voxels of all of the other LORs are given by means of simple translation rules. Before making the reconstruction, we trace the LORs of the nucleus to find the intersecting voxels, whose p(ij) values are computed and

  2. Pragmatic reconstruction methods in atom probe tomography

    International Nuclear Information System (INIS)

    Data collected in atom probe tomography have to be carefully analysed in order to give reliable composition data accurately and precisely positioned in the probed volume. Indeed, the large analysed surfaces of recent instruments require reconstruction methods taking into account not only the tip geometry but also accurate knowledge of geometrical projection parameters. This is particularly crucial in the analysis of multilayers materials or planar interfaces. The current work presents a simulation model that enables extraction of the two main projection features as a function of the tip and atom probe instrumentation geometries. Conversely to standard assumptions, the image compression factor and the field factor vary significantly during the analysis. An improved reconstruction method taking into account the intrinsic shape of a sample containing planar features is proposed to overcome this shortcoming. -- Highlights: → Tomographic reconstructions in atom probe tomography. → Model of field evaporation in a 2D non-regular geometry with cylindrical symmetry. → Calculation of the field factor and of the image compression factor. → New algorithm of reconstruction for specimen composed of flat layer structures.

  3. Cell volume and geometric parameters determination in living cells using confocal microscopy and 3D reconstruction

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: David Hevia, Aida Rodriguez-Garcia, Marta Alonso-Gervós, Isabel Quirós-González, Henar M Cimadevilla, Carmen Gómez-Cordovés, Rosa M Sainz & Juan C Mayo ### Abstract The protocol reported here describes a simple, easy, fast and reproducible method aimed to know the geometric parameters of living cells based on confocal laser scanning microscopy combined with 3D reconstruction software. Briefly, the method is based on intrinsic fluorescence properties of acridine orange (AO...

  4. Cryptotomography: reconstructing 3D Fourier intensities from randomly oriented single-shot diffraction patterns

    CERN Document Server

    Loh, N D; Elser, V; Barty, A; Boutet, S; Bajt, S; Hajdu, J; Ekeberg, T; Maia, F R N C; Schulz, J; Seibert, M M; Iwan, B; Timneanu, N; Marchesini, S; Schlichting, I; Shoeman, R L; Lomb, L; Frank, M; Liang, M; Chapman, H N

    2010-01-01

    We reconstructed the 3D Fourier intensity distribution of mono-disperse prolate nano-particles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast X-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the Expansion-Maximization-Compression (EMC) framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.

  5. Cryptotomography: Reconstructing 3D Fourier Intensities from Randomly Oriented Single-Shot Diffraction Patterns

    Science.gov (United States)

    Loh, N. D.; Bogan, M. J.; Elser, V.; Barty, A.; Boutet, S.; Bajt, S.; Hajdu, J.; Ekeberg, T.; Maia, F. R. N. C.; Schulz, J.; Seibert, M. M.; Iwan, B.; Timneanu, N.; Marchesini, S.; Schlichting, I.; Shoeman, R. L.; Lomb, L.; Frank, M.; Liang, M.; Chapman, H. N.

    2010-06-01

    We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY’s FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.

  6. 3D CAD model reconstruction of a human femur from MRI images

    Directory of Open Access Journals (Sweden)

    Benaissa EL FAHIME

    2013-05-01

    Full Text Available Medical practice and life sciences take full advantage of progress in engineering disciplines, in particular the computer assisted placement technique in hip surgery. This paper describes the three dimensional model reconstruction of human femur from MRI images. The developed program enables to obtain digital shape of 3D femur recognized by all CAD software and allows an accurate placement of the femoral component. This technic provides precise measurement of implant alignment during hip resurfacing or total hip arthroplasty, thereby reducing the risk of component mal-positioning and femoral neck notching.

  7. Molecular-Frame 3D Photoelectron Momentum Distributions by Tomographic Reconstruction

    DEFF Research Database (Denmark)

    Maurer, Jochen; Dimitrovski, Darko; Christensen, Lauge;

    2012-01-01

    Naphthalene molecules are fixed in space by a laser field and rotated, in 2° steps, over 180°. For each orientation, they are ionized by an intense, circularly polarized femtosecond laser pulse, and the 2D projection of the photoelectron momentum distribution is recorded. The molecular-frame 3D...... momentum distribution is obtained by tomographic reconstruction from all 90 projections. It reveals an anisotropic electron distribution, angularly shifted in the polarization plane, that is not accessible by the 2D momentum images. Our theoretical analysis shows that the magnitude of the angular shift...

  8. Incremental Multi-view 3D Reconstruction Starting from Two Images Taken by a Stereo Pair of Cameras

    Science.gov (United States)

    El hazzat, Soulaiman; Saaidi, Abderrahim; Karam, Antoine; Satori, Khalid

    2015-03-01

    In this paper, we present a new method for multi-view 3D reconstruction based on the use of a binocular stereo vision system constituted of two unattached cameras to initialize the reconstruction process. Afterwards , the second camera of stereo vision system (characterized by varying parameters) moves to capture more images at different times which are used to obtain an almost complete 3D reconstruction. The first two projection matrices are estimated by using a 3D pattern with known properties. After that, 3D scene points are recovered by triangulation of the matched interest points between these two images. The proposed approach is incremental. At each insertion of a new image, the camera projection matrix is estimated using the 3D information already calculated and new 3D points are recovered by triangulation from the result of the matching of interest points between the inserted image and the previous image. For the refinement of the new projection matrix and the new 3D points, a local bundle adjustment is performed. At first, all projection matrices are estimated, the matches between consecutive images are detected and Euclidean sparse 3D reconstruction is obtained. So, to increase the number of matches and have a more dense reconstruction, the Match propagation algorithm, more suitable for interesting movement of the camera, was applied on the pairs of consecutive images. The experimental results show the power and robustness of the proposed approach.

  9. Direct ambient noise tomography for 3-D near surface shear velocity structure: methodology and applications

    Science.gov (United States)

    Yao, H.; Fang, H.; Li, C.; Liu, Y.; Zhang, H.; van der Hilst, R. D.; Huang, Y. C.

    2014-12-01

    Ambient noise tomography has provided essential constraints on crustal and uppermost mantle shear velocity structure in global seismology. Recent studies demonstrate that high frequency (e.g., ~ 1 Hz) surface waves between receivers at short distances can be successfully retrieved from ambient noise cross-correlation and then be used for imaging near surface or shallow crustal shear velocity structures. This approach provides important information for strong ground motion prediction in seismically active area and overburden structure characterization in oil and gas fields. Here we propose a new tomographic method to invert all surface wave dispersion data for 3-D variations of shear wavespeed without the intermediate step of phase or group velocity maps.The method uses frequency-dependent propagation paths and a wavelet-based sparsity-constrained tomographic inversion. A fast marching method is used to compute, at each period, surface wave traveltimes and ray paths between sources and receivers. This avoids the assumption of great-circle propagation that is used in most surface wave tomographic studies, but which is not appropriate in complex media. The wavelet coefficients of the velocity model are estimated with an iteratively reweighted least squares (IRLS) algorithm, and upon iterations the surface wave ray paths and the data sensitivity matrix are updated from the newly obtained velocity model. We apply this new method to determine the 3-D near surface wavespeed variations in the Taipei basin of Taiwan, Hefei urban area and a shale and gas production field in China using the high-frequency interstation Rayleigh wave dispersion data extracted from ambient noisecross-correlation. The results reveal strong effects of off-great-circle propagation of high-frequency surface waves in these regions with above 30% shear wavespeed variations. The proposed approach is more efficient and robust than the traditional two-step surface wave tomography for imaging complex

  10. Accelerating Image Reconstruction in Three-Dimensional Optoacoustic Tomography on Graphics Processing Units

    CERN Document Server

    Wang, Kun; Kao, Yu-Jiun; Chou, Cheng-Ying; Oraevsky, Alexander A; Anastasio, Mark A; 10.1118/1.4774361

    2013-01-01

    Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image reconstruction is computationally burdensome. The aim of this work is to accelerate existing image reconstruction algorithms for 3D OAT by use of parallel programming techniques. Methods: Parallelization strategies are proposed to accelerate a filtered backprojection (FBP) algorithm and two different pairs of projection/backprojection operations that correspond to two different numerical imaging models. The algorithms are designed to fully exploit the parallel computing power of graphic processing units (GPUs). In order to evaluate the parallelization strategies for the projection/backprojection pairs, an iterative image reconstruction algorithm is implemented. Computer-simulation and experimental studies are conducted to investigate the computational efficiency and numerical a...

  11. Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3D X-ray CT

    OpenAIRE

    Cho, Jang Hwan; Fessler, Jeffrey A.

    2014-01-01

    Statistical image reconstruction methods for X-ray computed tomography (CT) provide improved spatial resolution and noise properties over conventional filtered back-projection (FBP) reconstruction, along with other potential advantages such as reduced patient dose and artifacts. Conventional regularized image reconstruction leads to spatially variant spatial resolution and noise characteristics because of interactions between the system models and the regularization. Previous regularization d...

  12. Implementation of a close range photogrammetric system for 3D reconstruction of a scoliotic torso

    Science.gov (United States)

    Detchev, Ivan Denislavov

    Scoliosis is a deformity of the human spine most commonly encountered with children. After being detected, periodic examinations via x-rays are traditionally used to measure its progression. However, due to the increased risk of cancer, a non-invasive and radiation-free scoliosis detection and progression monitoring methodology is needed. Quantifying the scoliotic deformity through the torso surface is a valid alternative, because of its high correlation with the internal spine curvature. This work proposes a low-cost multi-camera photogrammetric system for semi-automated 3D reconstruction of a torso surface with sub-millimetre level accuracy. The thesis describes the system design and calibration for optimal accuracy. It also covers the methodology behind the reconstruction and registration procedures. The experimental results include the complete reconstruction of a scoliotic torso mannequin. The final accuracy is evaluated through the goodness of fit between the reconstructed surface and a more accurate set of points measured by a coordinate measuring machine.

  13. Linear stratified approach using full geometric constraints for 3D scene reconstruction and camera calibration.

    Science.gov (United States)

    Kim, Jae-Hean; Koo, Bon-Ki

    2013-02-25

    This paper presents a new linear framework to obtain 3D scene reconstruction and camera calibration simultaneously from uncalibrated images using scene geometry. Our strategy uses the constraints of parallelism, coplanarity, colinearity, and orthogonality. These constraints can be obtained in general man-made scenes frequently. This approach can give more stable results with fewer images and allow us to gain the results with only linear operations. In this paper, it is shown that all the geometric constraints used in the previous works performed independently up to now can be implemented easily in the proposed linear method. The study on the situations that cannot be dealt with by the previous approaches is also presented and it is shown that the proposed method being able to handle the cases is more flexible in use. The proposed method uses a stratified approach, in which affine reconstruction is performed first and then metric reconstruction. In this procedure, the additional constraints newly extracted in this paper have an important role for affine reconstruction in practical situations.

  14. Development of a noncontact 3-D fluorescence tomography system for small animal in vivo imaging

    Science.gov (United States)

    Zhang, Xiaofeng; Badea, Cristian; Jacob, Mathews; Johnson, G. Allan

    2009-02-01

    Fluorescence imaging is an important tool for tracking molecular-targeting probes in preclinical studies. It offers high sensitivity, but nonetheless low spatial resolution compared to other leading imaging methods such CT and MRI. We demonstrate our methodological development in small animal in vivo whole-body imaging using fluorescence tomography. We have implemented a noncontact fluid-free fluorescence diffuse optical tomography system that uses a raster-scanned continuous-wave diode laser as the light source and an intensified CCD camera as the photodetector. The specimen is positioned on a motorized rotation stage. Laser scanning, data acquisition, and stage rotation are controlled via LabVIEW applications. The forward problem in the heterogeneous medium is based on a normalized Born method, and the sensitivity function is determined using a Monte Carlo method. The inverse problem (image reconstruction) is performed using a regularized iterative algorithm, in which the cost function is defined as a weighted sum of the L-2 norms of the solution image, the residual error, and the image gradient. The relative weights are adjusted by two independent regularization parameters. Our initial tests of this imaging system were performed with an imaging phantom that consists of a translucent plastic cylinder filled with tissue-simulating liquid and two thin-wall glass tubes containing indocyanine green. The reconstruction is compared to the output of a finite element method-based software package NIRFAST and has produced promising results.

  15. A review of automated image understanding within 3D baggage computed tomography security screening.

    Science.gov (United States)

    Mouton, Andre; Breckon, Toby P

    2015-01-01

    Baggage inspection is the principal safeguard against the transportation of prohibited and potentially dangerous materials at airport security checkpoints. Although traditionally performed by 2D X-ray based scanning, increasingly stringent security regulations have led to a growing demand for more advanced imaging technologies. The role of X-ray Computed Tomography is thus rapidly expanding beyond the traditional materials-based detection of explosives. The development of computer vision and image processing techniques for the automated understanding of 3D baggage-CT imagery is however, complicated by poor image resolutions, image clutter and high levels of noise and artefacts. We discuss the recent and most pertinent advancements and identify topics for future research within the challenging domain of automated image understanding for baggage security screening CT.

  16. 3D imaging using combined neutron-photon fan-beam tomography: A Monte Carlo study.

    Science.gov (United States)

    Hartman, J; Yazdanpanah, A Pour; Barzilov, A; Regentova, E

    2016-05-01

    The application of combined neutron-photon tomography for 3D imaging is examined using MCNP5 simulations for objects of simple shapes and different materials. Two-dimensional transmission projections were simulated for fan-beam scans using 2.5MeV deuterium-deuterium and 14MeV deuterium-tritium neutron sources, and high-energy X-ray sources, such as 1MeV, 6MeV and 9MeV. Photons enable assessment of electron density and related mass density, neutrons aid in estimating the product of density and material-specific microscopic cross section- the ratio between the two provides the composition, while CT allows shape evaluation. Using a developed imaging technique, objects and their material compositions have been visualized. PMID:26953978

  17. Monitoring 3D dose distributions in proton therapy by reconstruction using an iterative method.

    Science.gov (United States)

    Kim, Young-Hak; Yoon, Changyeon; Lee, Wonho

    2016-08-01

    The Bragg peak of protons can be determined by measuring prompt γ-rays. In this study, prompt γ-rays detected by single-photon emission computed tomography with a geometrically optimized collimation system were reconstructed by an iterative method. The falloff position by iterative method (52.48mm) was most similar to the Bragg peak (52mm) of an 80MeV proton compared with those of back-projection (54.11mm) and filtered back-projection (54.91mm) methods. Iterative method also showed better image performance than other methods. PMID:27179145

  18. Physical model from 3D ultrasound and magnetic resonance imaging scan data reconstruction of lumbosacral myelomeningocele in a fetus with Chiari II malformation.

    Science.gov (United States)

    Werner, Heron; Lopes, Jorge; Tonni, Gabriele; Araujo Júnior, Edward

    2015-04-01

    Rapid prototyping is becoming a fast-growing and valuable technique for physical models in case of congenital anomalies. Manufacturing models are generally built from three-dimensional (3D) ultrasound, computed tomography, and fetal magnetic resonance imaging (MRI) scan data. Physical prototype has demonstrated to be clinically of value in case of complex fetal malformations and may improve antenatal management especially in cases of craniosynostosis, orofacial clefts, and giant epignathus. In addition, it may enhance parental bonding in visually impaired parents and have didactic value in teaching program. Hereby, the first 3D physical model from 3D ultrasound and MRI scan data reconstruction of lumbosacral myelomeningocele in a third trimester fetus affected by Chiari II malformation is reported. PMID:25686895

  19. Reconstruction Error of Calibration Volume’s Coordinates for 3D Swimming Kinematics

    Science.gov (United States)

    Figueiredo, Pedro; Machado, Leandro; Vilas-Boas, João Paulo; Fernandes, Ricardo J.

    2011-01-01

    The aim of this study was to investigate the accuracy and reliability of above and underwater 3D reconstruction of three calibration volumes with different control points disposal (#1 - on vertical and horizontal rods; #2 - on vertical and horizontal rods and facets; #3 - on crossed horizontal rods). Each calibration volume (3 × 2 × 3 m) was positioned in a 25 m swimming pool (half above and half below the water surface) and recorded with four underwater and two above water synchronised cameras (50 Hz). Reconstruction accuracy was determined calculating the RMS error of twelve validation points. The standard deviation across all digitisation of the same marker was used for assessing the reliability estimation. Comparison among different number of control points showed that the set of 24 points produced the most accurate results. The volume #2 presented higher accuracy (RMS errors: 5.86 and 3.59 mm for x axis, 3.45 and 3.11 mm for y axis and 4.38 and 4.00 mm for z axis, considering under and above water, respectively) and reliability (SD: underwater cameras ± [0.2; 0.6] mm; above water cameras ± [0.2; 0.3] mm) that may be considered suitable for 3D swimming kinematic analysis. Results revealed that RMS error was greater during underwater analysis, possibly due to refraction. PMID:23486761

  20. Reconstructing 3D coastal cliffs from airborne oblique photographs without ground control points

    Science.gov (United States)

    Dewez, T. J. B.

    2014-05-01

    Coastal cliff collapse hazard assessment requires measuring cliff face topography at regular intervals. Terrestrial laser scanner techniques have proven useful so far but are expensive to use either through purchasing the equipment or through survey subcontracting. In addition, terrestrial laser surveys take time which is sometimes incompatible with the time during with the beach is accessible at low-tide. By comparison, structure from motion techniques (SFM) are much less costly to implement, and if airborne, acquisition of several kilometers of coastline can be done in a matter of minutes. In this paper, the potential of GPS-tagged oblique airborne photographs and SFM techniques is examined to reconstruct chalk cliff dense 3D point clouds without Ground Control Points (GCP). The focus is put on comparing the relative 3D point of views reconstructed by Visual SFM with their synchronous Solmeta Geotagger Pro2 GPS locations using robust estimators. With a set of 568 oblique photos, shot from the open door of an airplane with a triplet of synchronized Nikon D7000, GPS and SFM-determined view point coordinates converge to X: ±31.5 m; Y: ±39.7 m; Z: ±13.0 m (LE66). Uncertainty in GPS position affects the model scale, angular attitude of the reference frame (the shoreline ends up tilted by 2°) and absolute positioning. Ground Control Points cannot be avoided to orient such models.

  1. MULTIPARAMETER MEASUREMENT FOR RACEWAY GROOVE OF BEARING BASED ON 3D RECONSTRUCTION WITH DIGITAL STRUCTURED LIGHT

    Institute of Scientific and Technical Information of China (English)

    He Tao; Zhong Ming; Li Wei; Zhong Yuning; Shi Tielin

    2005-01-01

    A fast 3D reconstruction method based on structured light to measure various parameters of the raceway groove is presented. Digital parallel grating stripes distributed with sine density are projected onto the raceway groove by a DLP projector, and distorting of stripes is happened on the raceway. Simultaneously, aided by three-step phase-shifting approach, three images covered by different stripes are obtained by a high-resolution CCD camera at the same location, thus a more accuracy local topography can be obtained. And then the bearing is rotated on a high precision computer controlled rotational stage. Three images are also obtained as the former step at next planned location triggered by the motor. After one cycle, all images information is combined through the mosaics. As a result, the 3D information of raceway groove can be gained. Not only geometric properties but also surface flaws can be extracted by software. A preliminary hardware system has been built, with which some geometric parameters have been extracted from reconstructed local topography.

  2. A 3D endoscopy reconstruction as a saliency map for analysis of polyp shapes

    Science.gov (United States)

    Ruano, Josue; Martínez, Fabio; Gómez, Martín.; Romero, Eduardo

    2015-01-01

    A first diagnosis of colorectal cancer is performed by examination of polyp shape and appearance during an endoscopy routine procedure. However, the video-endoscopy is highly noisy because exacerbated physiological conditions like increased motility or secretion may limit the visual analysis of lesions. In this work a 3D reconstruction of the digestive tract is proposed, facilitating the polyp shape evaluation by highlighting its surface geometry and allowing an analysis from different perspectives. The method starts by a spatio-temporal map, constructed to group the different regions of the tract by their similar dynamic patterns during the sequence. Then, such map was convolved with a second derivative of a Gaussian kernel that emulates the camera distortion and allows to highlight the polyp surface. The position initialization in each frame of the kernel was computed from expert manual delineation and propagated along the sequence based on. Results show reliable reconstructions, with a salient 3D polyp structure that can then be better observed.

  3. Stereo-vision and 3D reconstruction for nuclear mobile robots

    International Nuclear Information System (INIS)

    In order to perceive the geometric structure of the surrounding environment of a mobile robot, a 3D reconstruction system has been developed. Its main purpose is to provide geometric information to an operator who has to telepilot the vehicle in a nuclear power plant. The perception system is split into two parts: the vision part and the map building part. Vision is enhanced with a fusion process that rejects bas samples over space and time. The vision is based on trinocular stereo-vision which provides a range image of the image contours. It performs line contour correlation on horizontal image pairs and vertical image pairs. The results are then spatially fused in order to have one distance image, with a quality independent of the orientation of the contour. The 3D reconstruction is based on grid-based sensor fusion. As the robot moves and perceives its environment, distance data is accumulated onto a regular square grid, taking into account the uncertainty of the sensor through a sensor measurement statistical model. This approach allows both spatial and temporal fusion. Uncertainty due to sensor position and robot position is also integrated into the absolute local map. This system is modular and generic and can integrate 2D laser range finder and active vision. (author)

  4. Spatial decomposition of molecular ions within 3D atom probe reconstructions.

    Science.gov (United States)

    Breen, Andrew; Moody, Michael P; Gault, Baptiste; Ceguerra, Anna V; Xie, Kelvin Y; Du, Sichao; Ringer, Simon P

    2013-09-01

    Two methods for separating the constituent atoms of molecular ions within atom probe tomography reconstructions are presented. The Gaussian Separation Method efficiently deconvolutes molecular ions containing two constituent atoms and is tested on simulated data before being applied to an experimental HSLA steel dataset containing NbN. The Delaunay Separation Method extends separation to larger complex ions and is also tested on simulated data before being applied to an experimental GaAs dataset containing many large (>3 atoms) complex ions. First nearest neighbour (1NN) distributions and images of the reconstruction before and after the separations are used to show the effect of the algorithms and their validity and practicality are also discussed. PMID:23522847

  5. On the 3-D reconstruction of Coronal Mass Ejections using coronagraph data

    Directory of Open Access Journals (Sweden)

    M. Mierla

    2010-01-01

    Full Text Available Coronal Mass ejections (CMEs are enormous eruptions of magnetized plasma expelled from the Sun into the interplanetary space, over the course of hours to days. They can create major disturbances in the interplanetary medium and trigger severe magnetic storms when they collide with the Earth's magnetosphere. It is important to know their real speed, propagation direction and 3-D configuration in order to accurately predict their arrival time at the Earth. Using data from the SECCHI coronagraphs onboard the STEREO mission, which was launched in October 2006, we can infer the propagation direction and the 3-D structure of such events. In this review, we first describe different techniques that were used to model the 3-D configuration of CMEs in the coronagraph field of view (up to 15 R⊙. Then, we apply these techniques to different CMEs observed by various coronagraphs. A comparison of results obtained from the application of different reconstruction algorithms is presented and discussed.

  6. AN IMAGE-BASED TECHNIQUE FOR 3D BUILDING RECONSTRUCTION USING MULTI-VIEW UAV IMAGES

    Directory of Open Access Journals (Sweden)

    F. Alidoost

    2015-12-01

    Full Text Available Nowadays, with the development of the urban areas, the automatic reconstruction of the buildings, as an important objects of the city complex structures, became a challenging topic in computer vision and photogrammetric researches. In this paper, the capability of multi-view Unmanned Aerial Vehicles (UAVs images is examined to provide a 3D model of complex building façades using an efficient image-based modelling workflow. The main steps of this work include: pose estimation, point cloud generation, and 3D modelling. After improving the initial values of interior and exterior parameters at first step, an efficient image matching technique such as Semi Global Matching (SGM is applied on UAV images and a dense point cloud is generated. Then, a mesh model of points is calculated using Delaunay 2.5D triangulation and refined to obtain an accurate model of building. Finally, a texture is assigned to mesh in order to create a realistic 3D model. The resulting model has provided enough details of building based on visual assessment.

  7. A new combined prior based reconstruction method for compressed sensing in 3D ultrasound imaging

    Science.gov (United States)

    Uddin, Muhammad S.; Islam, Rafiqul; Tahtali, Murat; Lambert, Andrew J.; Pickering, Mark R.

    2015-03-01

    Ultrasound (US) imaging is one of the most popular medical imaging modalities, with 3D US imaging gaining popularity recently due to its considerable advantages over 2D US imaging. However, as it is limited by long acquisition times and the huge amount of data processing it requires, methods for reducing these factors have attracted considerable research interest. Compressed sensing (CS) is one of the best candidates for accelerating the acquisition rate and reducing the data processing time without degrading image quality. However, CS is prone to introduce noise-like artefacts due to random under-sampling. To address this issue, we propose a combined prior-based reconstruction method for 3D US imaging. A Laplacian mixture model (LMM) constraint in the wavelet domain is combined with a total variation (TV) constraint to create a new regularization regularization prior. An experimental evaluation conducted to validate our method using synthetic 3D US images shows that it performs better than other approaches in terms of both qualitative and quantitative measures.

  8. Automatic Reconstruction of 3D Building Models from Terrestrial Laser Scanner Data

    Science.gov (United States)

    El Meouche, R.; Rezoug, M.; Hijazi, I.; Maes, D.

    2013-11-01

    With modern 3D laser scanners we can acquire a large amount of 3D data in only a few minutes. This technology results in a growing number of applications ranging from the digitalization of historical artifacts to facial authentication. The modeling process demands a lot of time and work (Tim Volodine, 2007). In comparison with the other two stages, the acquisition and the registration, the degree of automation of the modeling stage is almost zero. In this paper, we propose a new surface reconstruction technique for buildings to process the data obtained by a 3D laser scanner. These data are called a point cloud which is a collection of points sampled from the surface of a 3D object. Such a point cloud can consist of millions of points. In order to work more efficiently, we worked with simplified models which contain less points and so less details than a point cloud obtained in situ. The goal of this study was to facilitate the modeling process of a building starting from 3D laser scanner data. In order to do this, we wrote two scripts for Rhinoceros 5.0 based on intelligent algorithms. The first script finds the exterior outline of a building. With a minimum of human interaction, there is a thin box drawn around the surface of a wall. This box is able to rotate 360° around an axis in a corner of the wall in search for the points of other walls. In this way we can eliminate noise points. These are unwanted or irrelevant points. If there is an angled roof, the box can also turn around the edge of the wall and the roof. With the different positions of the box we can calculate the exterior outline. The second script draws the interior outline in a surface of a building. By interior outline we mean the outline of the openings like windows or doors. This script is based on the distances between the points and vector characteristics. Two consecutive points with a relative big distance will form the outline of an opening. Once those points are found, the interior outline

  9. AUTOMATIC MODEL SELECTION FOR 3D RECONSTRUCTION OF BUILDINGS FROM SATELLITE IMAGARY

    Directory of Open Access Journals (Sweden)

    T. Partovi

    2013-09-01

    Full Text Available Through the improvements of satellite sensor and matching technology, the derivation of 3D models from space borne stereo data obtained a lot of interest for various applications such as mobile navigation, urban planning, telecommunication, and tourism. The automatic reconstruction of 3D building models from space borne point cloud data is still an active research topic. The challenging problem in this field is the relatively low quality of the Digital Surface Model (DSM generated by stereo matching of satellite data comparing to airborne LiDAR data. In order to establish an efficient method to achieve high quality models and complete automation from the mentioned DSM, in this paper a new method based on a model-driven strategy is proposed. For improving the results, refined orthorectified panchromatic images are introduced into the process as additional data. The idea of this method is based on ridge line extraction and analysing height values in direction of and perpendicular to the ridgeline direction. After applying pre-processing to the orthorectified data, some feature descriptors are extracted from the DSM, to improve the automatic ridge line detection. Applying RANSAC a line is fitted to each group of ridge points. Finally these ridge lines are refined by matching them or closing gaps. In order to select the type of roof model the heights of point in extension of the ridge line and height differences perpendicular to the ridge line are analysed. After roof model selection, building edge information is extracted from canny edge detection and parameters derived from the roof parts. Then the best model is fitted to extracted façade roofs based on detected type of model. Each roof is modelled independently and final 3D buildings are reconstructed by merging the roof models with the corresponding walls.

  10. RECONSTRUCTION OF 3D VECTOR MODELS OF BUILDINGS BY COMBINATION OF ALS, TLS AND VLS DATA

    Directory of Open Access Journals (Sweden)

    H. Boulaassal

    2012-09-01

    Full Text Available Airborne Laser Scanning (ALS, Terrestrial Laser Scanning (TLS and Vehicle based Laser Scanning (VLS are widely used as data acquisition methods for 3D building modelling. ALS data is often used to generate, among others, roof models. TLS data has proven its effectiveness in the geometric reconstruction of building façades. Although the operating algorithms used in the processing chain of these two kinds of data are quite similar, their combination should be more investigated. This study explores the possibility of combining ALS and TLS data for simultaneously producing 3D building models from bird point of view and pedestrian point of view. The geometric accuracy of roofs and façades models is different due to the acquisition techniques. In order to take these differences into account, the surfaces composing roofs and façades are extracted with the same algorithm of segmentation. Nevertheless the segmentation algorithm must be adapted to the properties of the different point clouds. It is based on the RANSAC algorithm, but has been applied in a sequential way in order to extract all potential planar clusters from airborne and terrestrial datasets. Surfaces are fitted to planar clusters, allowing edge detection and reconstruction of vector polygons. Models resulting from TLS data are obviously more accurate than those generated from ALS data. Therefore, the geometry of the roofs is corrected and adapted according to the geometry of the corresponding façades. Finally, the effects of the differences between raw ALS and TLS data on the results of the modeling process are analyzed. It is shown that such combination could be used to produce reliable 3D building models.

  11. X-ray tomography: Biological cells in 3-D at better than 50 nm resolution

    International Nuclear Information System (INIS)

    Full text: X-ray microscopy can be used to image whole, hydrated, specimens with a spatial resolution 5-10 times better than that obtained using visible light microscopy. X-ray imaging at photon energies below the K- absorption edge of oxygen, referred to as the water window, exploits the strong natural contrast for organic material embedded in a mostly water matrix. With a transmission X-ray microscope using Fresnel zone plate optics, specimens up to 10 microns thick can be examined. The highest X-ray transmission in hydrated samples is obtained at a wavelength of 2.4 nm but, due to the low numerical aperture of zone plate lenses operated in st order diffraction mode the structures resolved are much larger than the X-ray wavelength. Because of the low NA of X-ray lenses (NA=0.05), combined with the effect of polychromatic illumination and a wavelength dependant focal length, the effective depth of ld is large (6-10 microns). The experiments presented here were performed at the Advanced Light Source using the full ld transmission X-ray microscope, XM-1. This microscope employs a bend magnet X-ray source and zone plate condenser and objective lenses. The condenser zone plate acts as a monochromator and the X-ray images are recorded directly on a cooled, back-thinned 1024x1024 pixel CCD camera. The sample holder was a rotationally symmetric glass tube; the region containing the sample was 10 microns in diameter with a wall thickness of 200 nm. Live yeast cells were loaded into the tube, rapidly frozen by a blast of liquid nitrogen-cooled helium gas, and maintained at 140 deg C by a steady flow of cold helium. The image sequence spanned 180 deg and consisted of 45 images spaced by 4 deg. The images were aligned to a common axis and computed tomographic reconstruction was used to obtain the 3-D X-ray linear absorption coefficient. Volume rendering and animation of reconstructed data was performed using the 3-D program, Amira. Acquisition time for 90 images was 3 min

  12. Morphological and electrochemical cycling effects in MnO2 nanostructures by 3D electron tomography

    KAUST Repository

    Chen, Wei

    2014-02-12

    In this study, MnO2 nanostructures with well-controlled morphology and crystal phase are successfully prepared by chemical synthesis, and characterized by three-dimensional electron tomography for use as supercapacitor electrode materials. The growth process of the various MnO 2 nanostructures is revealed in detail, and correlated to their electrochemical performance as supercapacitor materials. The specific capacitance of MnO2 electrodes is found to be strongly correlated with the inner morphology and crystal phase of the MnO2 nanostructures. Furthermore, it is demonstrated that the increased capacity with electrochemical cycling of the materials is due to the formation of defective regions embedded in the MnO2 nanostructures; these regions form during electrochemical cycling of the electrodes, resulting in increased porosity, surface area, and consequently, increased electrochemical capacity. The preparation, characterization and supercapacitor application of MnO 2 nanostructures by 3D electron tomography are studied. The electrochemical performance of MnO2 is correlated to its surface area, determined by the morphological effect, as well as the cycling effect, determined by the formation of defective regions on the nanostructures during electrochemical cycling tests. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. 3D reconstruction and spatial auralization of the "Painted Dolmen" of Antelas

    Science.gov (United States)

    Dias, Paulo; Campos, Guilherme; Santos, Vítor; Casaleiro, Ricardo; Seco, Ricardo; Sousa Santos, Beatriz

    2008-02-01

    This paper presents preliminary results on the development of a 3D audiovisual model of the Anta Pintada (painted dolmen) of Antelas, a Neolithic chamber tomb located in Oliveira de Frades and listed as Portuguese national monument. The final aim of the project is to create a highly accurate Virtual Reality (VR) model of this unique archaeological site, capable of providing not only visual but also acoustic immersion based on its actual geometry and physical properties. The project started in May 2006 with in situ data acquisition. The 3D geometry of the chamber was captured using a Laser Range Finder. In order to combine the different scans into a complete 3D visual model, reconstruction software based on the Iterative Closest Point (ICP) algorithm was developed using the Visualization Toolkit (VTK). This software computes the boundaries of the room on a 3D uniform grid and populates its interior with "free-space nodes", through an iterative algorithm operating like a torchlight illuminating a dark room. The envelope of the resulting set of "free-space nodes" is used to generate a 3D iso-surface approximating the interior shape of the chamber. Each polygon of this surface is then assigned the acoustic absorption coefficient of the corresponding boundary material. A 3D audiovisual model operating in real-time was developed for a VR Environment comprising head-mounted display (HMD) I-glasses SVGAPro, an orientation sensor (tracker) InterTrax 2 with 3 Degrees Of Freedom (3DOF) and stereo headphones. The auralisation software is based on a geometric model. This constitutes a first approach, since geometric acoustics have well-known limitations in rooms with irregular surfaces. The immediate advantage lies in their inherent computational efficiency, which allows real-time operation. The program computes the early reflections forming the initial part of the chamber's impulse response (IR), which carry the most significant cues for source localisation. These early

  14. Three-dimensional reconstruction in free-space whole-body fluorescence tomography of mice using optically reconstructed surface and atlas anatomy

    Science.gov (United States)

    Zhang, Xiaofeng; Badea, Cristian T.; Johnson, G. Allan

    2009-11-01

    We present a 3-D image reconstruction method for free-space fluorescence tomography of mice using hybrid anatomical prior information. Specifically, we use an optically reconstructed surface of the experimental animal and a digital mouse atlas to approximate the anatomy of the animal as structural priors to assist image reconstruction. Experiments are carried out on a cadaver of a nude mouse with a fluorescent inclusion (2.4-mm-diam cylinder) implanted in the chest cavity. Tomographic fluorescence images are reconstructed using an iterative algorithm based on a finite element method. Coregistration of the fluorescence reconstruction and micro-CT (computed tomography) data acquired afterward show good localization accuracy (localization error 1.2+/-0.6 mm). Using the optically reconstructed surface, but without the atlas anatomy, image reconstruction fails to show the fluorescent inclusion correctly. The method demonstrates the utility of anatomical priors in support of free-space fluorescence tomography.

  15. The Availability of Radiological Measurement of Femoral Anteversion Angle: Three-Dimensional Computed Tomography Reconstruction

    OpenAIRE

    Byun, Ha Young; Shin, Heesuk; Lee, Eun Shin; Kong, Min Sik; Lee, Seung Hun; Lee, Chang Hee

    2016-01-01

    Objective To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT). Methods The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement w...

  16. The Availability of Radiological Measurement of Tibial Torsion: Three-Dimensional Computed Tomography Reconstruction

    OpenAIRE

    Shin, Sang-yeop; Yoon, Chul Ho; Lee, Eun Shin; Oh, Min-Kyun; Kim, A Ram; Park, Jong Moon; Shin, Jun-Hwa; Shin, Hee Suk

    2011-01-01

    Objective To assess the intra-rater and inter-rater reliability for measuring tibial torsion measurements by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT) and to compare the physical measures to those of 3D-CT. Method The study included 33 children who presented with intoeing gait. Tibial torsion was measured by 3D-CT. Distal reference point was the bimalleolar axis. Proximal reference points were the transtibial axis and posterior condylar axis. Phy...

  17. 3D-ANTLERS: Virtual Reconstruction and Three-Dimensional Measurement

    Science.gov (United States)

    Barba, S.; Fiorillo, F.; De Feo, E.

    2013-02-01

    The main objective of this paper is to establish a procedural method for measuring and cataloguing antlers through the use of laser scanner and of a 3D reconstruction of complex modeling. The deer's antlers have been used as a test and subjected to capture and measurement. For this purpose multiple data sources techniques have been studied and compared, (also considering low-cost sensors) estimating the accuracy and its errors in order to demonstrate the validity of the process. A further development is the comparison of results with applications of digital photogrammetry, considering also cloud computing software. The study has began with an introduction to sensors, addressing the underlying characteristics of the technology available, the scope and the limits of these applications. We have focused particularly on the "structured light", as the acquisition will be completed through three-dimensional scanners: DAVID and the ARTEC MH. The first is a low-cost sensor, a basic webcam and a linear laser pointer, red coloured, that leads to acquisition of three-dimensional strips. The other one is a hand scanner; even in this case we will explain how to represent a 3D model, with a pipeline that provides data export from the "proprietary" to a "reverse engineering" software. Typically, these are the common steps to the two approaches that have been performed in WRAP format: point sampling, manual and global registration, repair normals, surface editing and texture projection. In fact, after a first and common data processing was done with the use of a software supplied with the equipment, the proto-models thus obtained were treated in Geomagic Studio, which was also chosen to allow the homogenization and standardization of data in order to make a more objective comparison. It is commonplace to observe that the editing of the digital mock-up obtained with the DAVID - which had not yet been upgraded to the 3.5 release at the time of this study - is substantially different

  18. 3D chemical mapping: application of scanning transmission (soft) X-ray microscopy (STXM) in combination with angle-scan tomography in bio-, geo-, and environmental sciences.

    Science.gov (United States)

    Obst, Martin; Schmid, Gregor

    2014-01-01

    The identification of environmental processes and mechanisms often requires information on the organochemical and inorganic composition of specimens at high spatial resolution. X-ray spectroscopy (XAS) performed in the soft X-ray range (100-2,200 eV) provides chemical speciation information for elements that are of high biogeochemical relevance such as carbon, nitrogen, and oxygen but also includes transition metals such as iron, manganese, or nickel. Synchrotron-based scanning transmission X-ray microscopy (STXM) combines XAS with high resolution mapping on the 20-nm scale. This provides two-dimensional (2D) quantitative information about the distribution of chemical species such as organic macromolecules, metals, or mineral phases within environmental samples. Furthermore, the combination of STXM with angle-scan tomography allows for three-dimensional (3D) spectromicroscopic analysis of bio-, geo-, or environmental samples. For the acquisition of STXM tomography data, the sample is rotated around an axis perpendicular to the X-ray beam. Various sample preparation approaches such as stripes cut from TEM grids or the preparation of wet cells allow for preparing environmentally relevant specimens in a dry or in a fully hydrated state for 2D and 3D STXM measurements. In this chapter we give a short overview about the principles of STXM, its application to environmental sciences, different preparation techniques, and the analysis and 3D reconstruction of STXM tomography data.

  19. 3D VIRTUAL RECONSTRUCTION OF AN URBAN HISTORICAL SPACE: A CONSIDERATION ON THE METHOD

    Directory of Open Access Journals (Sweden)

    M. Galizia

    2012-09-01

    Full Text Available Urban historical spaces are often characterized by a variety of shapes, geometries, volumes, materials. Their virtual reconstruction requires a critical approach in terms of acquired data's density, timing optimization, final product's quality and slimness. The research team has focused its attention on the study on Francesco Neglia square (previously named Saint Thomas square in Enna. This square is an urban space fronted by architectures which present historical and stylistic differences. For example you can find the Saint Thomas'church belfry (in aragounese-catalan stile dated XIV century and the porch, the Anime Sante baroque's church (XVII century, Saint Mary of the Grace's nunnery (XVIII century and as well as some civil buildings of minor importance built in the mid twentieth century. The research has compared two different modeling tools approaches: the first one is based on the construction of triangulated surfaces which are segmented and simplified; the second one is based on the detection of surfaces geometrical features, the extraction of the more significant profiles by using a software dedicated to the elaboration of cloud points and the subsequent mathematical reconstruction by using a 3d modelling software. The following step was aimed to process the virtual reconstruction of urban scene by assembling the single optimized models. This work highlighted the importance of the image of the operator and of its cultural contribution, essential to recognize geometries which generates surfaces in order to create high quality semantic models.

  20. THE PERFORMANCE EVALUATION OF MULTI-IMAGE 3D RECONSTRUCTION SOFTWARE WITH DIFFERENT SENSORS

    Directory of Open Access Journals (Sweden)

    V. Mousavi

    2015-12-01

    Full Text Available Today, multi-image 3D reconstruction is an active research field and generating three dimensional model of the objects is one the most discussed issues in Photogrammetry and Computer Vision that can be accomplished using range-based or image-based methods. Very accurate and dense point clouds generated by range-based methods such as structured light systems and laser scanners has introduced them as reliable tools in the industry. Image-based 3D digitization methodologies offer the option of reconstructing an object by a set of unordered images that depict it from different viewpoints. As their hardware requirements are narrowed down to a digital camera and a computer system, they compose an attractive 3D digitization approach, consequently, although range-based methods are generally very accurate, image-based methods are low-cost and can be easily used by non-professional users. One of the factors affecting the accuracy of the obtained model in image-based methods is the software and algorithm used to generate three dimensional model. These algorithms are provided in the form of commercial software, open source and web-based services. Another important factor in the accuracy of the obtained model is the type of sensor used. Due to availability of mobile sensors to the public, popularity of professional sensors and the advent of stereo sensors, a comparison of these three sensors plays an effective role in evaluating and finding the optimized method to generate three-dimensional models. Lots of research has been accomplished to identify a suitable software and algorithm to achieve an accurate and complete model, however little attention is paid to the type of sensors used and its effects on the quality of the final model. The purpose of this paper is deliberation and the introduction of an appropriate combination of a sensor and software to provide a complete model with the highest accuracy. To do this, different software, used in previous

  1. The Performance Evaluation of Multi-Image 3d Reconstruction Software with Different Sensors

    Science.gov (United States)

    Mousavi, V.; Khosravi, M.; Ahmadi, M.; Noori, N.; Naveh, A. Hosseini; Varshosaz, M.

    2015-12-01

    Today, multi-image 3D reconstruction is an active research field and generating three dimensional model of the objects is one the most discussed issues in Photogrammetry and Computer Vision that can be accomplished using range-based or image-based methods. Very accurate and dense point clouds generated by range-based methods such as structured light systems and laser scanners has introduced them as reliable tools in the industry. Image-based 3D digitization methodologies offer the option of reconstructing an object by a set of unordered images that depict it from different viewpoints. As their hardware requirements are narrowed down to a digital camera and a computer system, they compose an attractive 3D digitization approach, consequently, although range-based methods are generally very accurate, image-based methods are low-cost and can be easily used by non-professional users. One of the factors affecting the accuracy of the obtained model in image-based methods is the software and algorithm used to generate three dimensional model. These algorithms are provided in the form of commercial software, open source and web-based services. Another important factor in the accuracy of the obtained model is the type of sensor used. Due to availability of mobile sensors to the public, popularity of professional sensors and the advent of stereo sensors, a comparison of these three sensors plays an effective role in evaluating and finding the optimized method to generate three-dimensional models. Lots of research has been accomplished to identify a suitable software and algorithm to achieve an accurate and complete model, however little attention is paid to the type of sensors used and its effects on the quality of the final model. The purpose of this paper is deliberation and the introduction of an appropriate combination of a sensor and software to provide a complete model with the highest accuracy. To do this, different software, used in previous studies, were compared and

  2. Clinical anatomy and 3D virtual reconstruction of the lumbar plexus with respect to lumbar surgery

    Directory of Open Access Journals (Sweden)

    Ding Zi-hai

    2011-04-01

    Full Text Available Abstract Background Exposure of the anterior or lateral lumbar via the retroperitoneal approach easily causes injuries to the lumbar plexus. Lumbar plexus injuries which occur during anterior or transpsoas lumbar spine exposure and placement of instruments have been reported. This study aims is to provide more anatomical data and surgical landmarks in operations concerning the lumbar plexus in order to prevent lumbar plexus injuries and to increase the possibility of safety in anterior approach lumbar surgery. Methods To study the applied anatomy related to the lumbar plexus of fifteen formaldehyde-preserved cadavers, Five sets of Virtual Human (VH data set were prepared and used in the study. Three-dimensional (3D computerized reconstructions of the lumbar plexus and their adjacent structures were conducted from the VH female data set. Results The order of lumbar nerves is regular. From the anterior view, lumbar plexus nerves are arranged from medial at L5 to lateral at L2. From the lateral view, lumbar nerves are arranged from ventral at L2 to dorsal at L5. The angle of each nerve root exiting outward to the corresponding intervertebral foramen increases from L1 to L5. The lumbar plexus nerves are observed to be in close contact with transverse processes (TP. All parts of the lumbar plexus were located by sectional anatomy in the dorsal third of the psoas muscle. Thus, access to the psoas major muscle at the ventral 2/3 region can safely prevent nerve injuries. 3D reconstruction of the lumbar plexus based on VCH data can clearly show the relationships between the lumbar plexus and the blood vessels, vertebral body, kidney, and psoas muscle. Conclusion The psoas muscle can be considered as a surgical landmark since incision at the ventral 2/3 of the region can prevent lumbar plexus injuries for procedures requiring exposure of the lateral anterior of the lumbar. The transverse process can be considered as a landmark and reference in surgical

  3. Inlining 3d Reconstruction, Multi-Source Texture Mapping and Semantic Analysis Using Oblique Aerial Imagery

    Science.gov (United States)

    Frommholz, D.; Linkiewicz, M.; Poznanska, A. M.

    2016-06-01

    This paper proposes an in-line method for the simplified reconstruction of city buildings from nadir and oblique aerial images that at the same time are being used for multi-source texture mapping with minimal resampling. Further, the resulting unrectified texture atlases are analyzed for façade elements like windows to be reintegrated into the original 3D models. Tests on real-world data of Heligoland/ Germany comprising more than 800 buildings exposed a median positional deviation of 0.31 m at the façades compared to the cadastral map, a correctness of 67% for the detected windows and good visual quality when being rendered with GPU-based perspective correction. As part of the process building reconstruction takes the oriented input images and transforms them into dense point clouds by semi-global matching (SGM). The point sets undergo local RANSAC-based regression and topology analysis to detect adjacent planar surfaces and determine their semantics. Based on this information the roof, wall and ground surfaces found get intersected and limited in their extension to form a closed 3D building hull. For texture mapping the hull polygons are projected into each possible input bitmap to find suitable color sources regarding the coverage and resolution. Occlusions are detected by ray-casting a full-scale digital surface model (DSM) of the scene and stored in pixel-precise visibility maps. These maps are used to derive overlap statistics and radiometric adjustment coefficients to be applied when the visible image parts for each building polygon are being copied into a compact texture atlas without resampling whenever possible. The atlas bitmap is passed to a commercial object-based image analysis (OBIA) tool running a custom rule set to identify windows on the contained façade patches. Following multi-resolution segmentation and classification based on brightness and contrast differences potential window objects are evaluated against geometric constraints and

  4. Post-processing methods of rendering and visualizing 3-D reconstructed tomographic images

    Energy Technology Data Exchange (ETDEWEB)

    Wong, S.T.C. [Univ. of California, San Francisco, CA (United States)

    1997-02-01

    The purpose of this presentation is to discuss the computer processing techniques of tomographic images, after they have been generated by imaging scanners, for volume visualization. Volume visualization is concerned with the representation, manipulation, and rendering of volumetric data. Since the first digital images were produced from computed tomography (CT) scanners in the mid 1970s, applications of visualization in medicine have expanded dramatically. Today, three-dimensional (3D) medical visualization has expanded from using CT data, the first inherently digital source of 3D medical data, to using data from various medical imaging modalities, including magnetic resonance scanners, positron emission scanners, digital ultrasound, electronic and confocal microscopy, and other medical imaging modalities. We have advanced from rendering anatomy to aid diagnosis and visualize complex anatomic structures to planning and assisting surgery and radiation treatment. New, more accurate and cost-effective procedures for clinical services and biomedical research have become possible by integrating computer graphics technology with medical images. This trend is particularly noticeable in current market-driven health care environment. For example, interventional imaging, image-guided surgery, and stereotactic and visualization techniques are now stemming into surgical practice. In this presentation, we discuss only computer-display-based approaches of volumetric medical visualization. That is, we assume that the display device available is two-dimensional (2D) in nature and all analysis of multidimensional image data is to be carried out via the 2D screen of the device. There are technologies such as holography and virtual reality that do provide a {open_quotes}true 3D screen{close_quotes}. To confine the scope, this presentation will not discuss such approaches.

  5. Interface Orientation Distribution during Grain Growth in Bulk SrTiO3 Measured by Means of 3D X-Ray Diffraction Contrast Tomography

    DEFF Research Database (Denmark)

    Syha, Melanie; Rheinheimer, Wolfgang; Bäurer, Michael;

    2012-01-01

    3D x-ray diffraction contrast tomography (DCT) is a non-destructive technique for the determination of grain shape and crystallography in polycrystalline bulk materials. Using this technique, a strontium titanate specimen was repeatedly measured between annealing steps.. A systematic analysis of ...... normal distribution clearly shows a preference for (100) oriented interfaces in the selected grains when annealed at 1600°C. This observation can be connected to existent interfacial energy estimations resulting from capillarity vector reconstructions. © 2012 Materials Research Society....

  6. The development of 3-D tomography method based on gamma-scanning of irradiated fuel rods

    Energy Technology Data Exchange (ETDEWEB)

    Dobrin, R. [RENEL, Nuclear Power Group, Inst. for Nuclear Research (INR), Post-Irradiation Examination Lab., Pitesti (Romania); Craciunescu, T. [National Inst. of Nuclear Physics and Engineering, Horia Hulubei (IFIN-HH) Lab., Bucharest, Magurele (Romania)

    1999-07-01

    The tomographic method, consisting in the reconstruction of the images from their projections, is a relatively new nondestructive method, used in the post-irradiation examination of the nuclear fuel. The purpose of the method is to determine the distribution of gamma radioactive fission products in a cross-section of an irradiated nuclear fuel rods. More than 40 fuel rods were investigated at the INR hot cell facility, using this nondestructive technique. The method is used in conjunction with the gamma scanning method and the equipment used for tomographic investigation of the irradiated nuclear fuel is the same to that usually used for gamma scanning investigation. The paper presents the principles of the Gamma Emission Computed Tomography (GECT), as well as the results and performance of this method, when applied to the investigation of some types of fuel rods, irradiated in the TRIGA 14 MW{sub th} materials testing reactor. (author)

  7. Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study*

    OpenAIRE

    Gao, Nuo; Zhu, Shan-an; He, Bin

    2005-01-01

    We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types o...

  8. A new multiresolution method applied to the 3D reconstruction of small bodies

    Science.gov (United States)

    Capanna, C.; Jorda, L.; Lamy, P. L.; Gesquiere, G.

    2012-12-01

    The knowledge of the three-dimensional (3D) shape of small solar system bodies, such as asteroids and comets, is essential in determining their global physical properties (volume, density, rotational parameters). It also allows performing geomorphological studies of their surface through the characterization of topographic features, such as craters, faults, landslides, grooves, hills, etc.. In the case of small bodies, the shape is often only constrained by images obtained by interplanetary spacecrafts. Several techniques are available to retrieve 3D global shapes from these images. Stereography which relies on control points has been extensively used in the past, most recently to reconstruct the nucleus of comet 9P/Tempel 1 [Thomas (2007)]. The most accurate methods are however photogrammetry and photoclinometry, often used in conjunction with stereography. Stereophotogrammetry (SPG) has been used to reconstruct the shapes of the nucleus of comet 19P/Borrelly [Oberst (2004)] and of the asteroid (21) Lutetia [Preusker (2012)]. Stereophotoclinometry (SPC) has allowed retrieving an accurate shape of the asteroids (25143) Itokawa [Gaskell (2008)] and (2867) Steins [Jorda (2012)]. We present a new photoclinometry method based on the deformation of a 3D triangular mesh [Capanna (2012)] using a multi-resolution scheme which starts from a sphere of 300 facets and yields a shape model with 100; 000 facets. Our strategy is inspired by the "Full Multigrid" method [Botsch (2007)] and consists in going alternatively between two resolutions in order to obtain an optimized shape model at a given resolution before going to the higher resolution. In order to improve the robustness of our method, we use a set of control points obtained by stereography. Our method has been tested on images acquired by the OSIRIS visible camera, aboard the Rosetta spacecraft of the European Space Agency, during the fly-by of asteroid (21) Lutetia in July 2010. We present the corresponding 3D shape

  9. Operator-free, film-based 3D seed reconstruction in brachytherapy

    International Nuclear Information System (INIS)

    In brachytherapy implants, the accuracy of dose calculation depends on the ability to localize radioactive sources correctly. If performed manually using planar images, this is a time-consuming and often error-prone process - primarily because each seed must be identified on (at least) two films. In principle, three films should allow automatic seed identification and position reconstruction; however, practical implementation of the numerous algorithms proposed so far appears to have only limited reliability. The motivation behind this work is to create a fast and reliable system for real-time implant evaluation using digital planar images obtained from radiotherapy simulators, or mobile x-ray/fluoroscopy systems. We have developed algorithms and code for 3D seed coordinate reconstruction. The input consists of projections of seed positions in each of three isocentric images taken at arbitrary angles. The method proposed here consists of a set of heuristic rules (in a sense, a learning algorithm) that attempts to minimize seed misclassifications. In the clinic, this means that the system must be impervious to errors resulting from patient motion as well as from finite tolerances accepted in equipment settings. The software program was tested with simulated data, a pelvic phantom and patient data. One hundred and twenty permanent prostate implants were examined (105125I and 15103Pd) with the number of seeds ranging from 35 to 138 (average 79). The mean distance between actual and reconstructed seed positions is in the range 0.03-0.11 cm. On a Pentium III computer at 600 MHz the reconstruction process takes 10-30 s. The total number of seeds is independently validated. The process is robust and able to account for errors introduced in the clinic. (author)

  10. Sparse Bayesian framework applied to 3D super-resolution reconstruction in fetal brain MRI

    Science.gov (United States)

    Becerra, Laura C.; Velasco Toledo, Nelson; Romero Castro, Eduardo

    2015-01-01

    Fetal Magnetic Resonance (FMR) is an imaging technique that is becoming increasingly important as allows assessing brain development and thus make an early diagnostic of congenital abnormalities, spatial resolution is limited by the short acquisition time and the unpredictable fetus movements, in consequence the resulting images are characterized by non-parallel projection planes composed by anisotropic voxels. The sparse Bayesian representation is a flexible strategy which is able to model complex relationships. The Super-resolution is approached as a regression problem, the main advantage is the capability to learn data relations from observations. Quantitative performance evaluation was carried out using synthetic images, the proposed method demonstrates a better reconstruction quality compared with standard interpolation approach. The presented method is a promising approach to improve the information quality related with the 3-D fetal brain structure. It is important because allows assessing brain development and thus make an early diagnostic of congenital abnormalities.

  11. QUALITY ASSESSMENT OF 3D RECONSTRUCTION USING FISHEYE AND PERSPECTIVE SENSORS

    Directory of Open Access Journals (Sweden)

    C. Strecha

    2015-03-01

    Full Text Available Recent mathematical advances, growing alongside the use of unmanned aerial vehicles, have not only overcome the restriction of roll and pitch angles during flight but also enabled us to apply non-metric cameras in photogrammetric method, providing more flexibility for sensor selection. Fisheye cameras, for example, advantageously provide images with wide coverage; however, these images are extremely distorted and their non-uniform resolutions make them more difficult to use for mapping or terrestrial 3D modelling. In this paper, we compare the usability of different camera-lens combinations, using the complete workflow implemented in Pix4Dmapper to achieve the final terrestrial reconstruction result of a well-known historical site in Switzerland: the Chillon Castle. We assess the accuracy of the outcome acquired by consumer cameras with perspective and fisheye lenses, comparing the results to a laser scanner point cloud.

  12. Data Management Framework of Drone-Based 3d Model Reconstruction of Disaster Site

    Science.gov (United States)

    Kim, C.; Moon, H.; Lee, W.

    2016-06-01

    To rescue peoples in the disaster site in time, information acquisition of current feature of collapsed buildings and terrain is quite important for disaster site rescue manager. Based on information about disaster site, they can accurately plan the rescue process and remove collapsed buildings or other facilities. However, due to the harsh condition of disaster areas, rapid and accurate acquisition of disaster site information is not an easy task. There are possibilities of further damages in the collapse and there are also difficulties in acquiring information about current disaster situation due to large disaster site and limited rescue resources. To overcome these circumstances of disaster sites, an unmanned aerial vehicle, commonly known as a drone is used to rapidly and effectively acquire current image data of the large disaster areas. Then, the procedure of drone-based 3D model reconstruction visualization function of developed system is presented.

  13. 3D reconstruction of the source and scale of buried young flood channels on Mars.

    Science.gov (United States)

    Morgan, Gareth A; Campbell, Bruce A; Carter, Lynn M; Plaut, Jeffrey J; Phillips, Roger J

    2013-05-01

    Outflow channels on Mars are interpreted as the product of gigantic floods due to the catastrophic eruption of groundwater that may also have initiated episodes of climate change. Marte Vallis, the largest of the young martian outflow channels (Mars hydrologic activity during a period otherwise considered to be cold and dry. Using data from the Shallow Radar sounder on the Mars Reconnaissance Orbiter, we present a three-dimensional (3D) reconstruction of buried channels on Mars and provide estimates of paleohydrologic parameters. Our work shows that Cerberus Fossae provided the waters that carved Marte Vallis, and it extended an additional 180 kilometers to the east before the emplacement of the younger lava flows. We identified two stages of channel incision and determined that channel depths were more than twice those of previous estimates.

  14. EFFECT OF DIGITAL FRINGE PROJECTION PARAMETERS ON 3D RECONSTRUCTION ACCURACY

    Directory of Open Access Journals (Sweden)

    A. Babaei

    2013-09-01

    This paper aims to evaluate different parameters which affect the accuracy of the final results. For this purpose, some test were designed and implemented. These tests assess the number of phase shifts, spatial frequency of the fringe pattern, light condition, noise level of images, and the color and material of target objects on the quality of resulted phase map. The evaluation results demonstrate that digital fringe projection method is capable of obtaining depth map of complicated object with high accuracy. The contrast test results showed that this method is able to work under different ambient light condition; although at places with high light condition will not work properly. The results of implementation on different objects with various materials, color and shapes demonstrate the high capability of this method of 3D reconstruction.

  15. 3D Reconstruction Using Interval Methods on The Kinect Device Coupled With an IMU

    Directory of Open Access Journals (Sweden)

    Aymeric Bethencourt

    2013-02-01

    Full Text Available The principle behind VSLAM applications like 3D object reconstruction or indoor mapping is to estimate the spatial transformation between two large clouds of points, which represent two poses of the same scene. They can further be processed to obtain detailed surfaces. Since its introduction in 1992, the standard algorithm for finding the alignment between two point clouds is ICP (Iterative Closest Point and its variants, combined with RANSAC (RANdom SAmple Consensus. This paper presents a new approach using interval analysis. The idea is to define large intervals for the transformation parameters between the poses then to successively contract those intervals using the equations of the transformation of corresponding points between the poses. To contract those intervals faster, we added an IMU (Inertial Measurement Unit to our system so the initial intervals of the parameters are already small before applying the contractions. We implemented our algorithm using the middleware ROS (Robot Operating System and stated our performances.

  16. 3D Power Line Reconstruction from Airborne LiDAR Point Cloud of Overhead Electric Power Transmission Corridors

    OpenAIRE

    LIN Xiangguo; Zhang, Jixian

    2016-01-01

    3D power line reconstruction is one of the main tasks in power line patrols using LiDAR systems mounted on helicopters. A 3D reconstruction method is proposed to reconstruct the power lines from the airborne LiDAR point clouds of the overhead electric power transmission corridors. Firstly, the pylons' LiDAR points and the initial routine trajectory of the transmission lines are employed to derive the precise information such as the locations and number of the pylons, the real routine trajecto...

  17. Region-Based 3d Surface Reconstruction Using Images Acquired by Low-Cost Unmanned Aerial Systems

    Science.gov (United States)

    Lari, Z.; Al-Rawabdeh, A.; He, F.; Habib, A.; El-Sheimy, N.

    2015-08-01

    Accurate 3D surface reconstruction of our environment has become essential for an unlimited number of emerging applications. In the past few years, Unmanned Aerial Systems (UAS) are evolving as low-cost and flexible platforms for geospatial data collection that could meet the needs of aforementioned application and overcome limitations of traditional airborne and terrestrial mobile mapping systems. Due to their payload restrictions, these systems usually include consumer-grade imaging and positioning sensor which will negatively impact the quality of the collected geospatial data and reconstructed surfaces. Therefore, new surface reconstruction surfaces are needed to mitigate the impact of using low-cost sensors on the final products. To date, different approaches have been proposed to for 3D surface construction using overlapping images collected by imaging sensor mounted on moving platforms. In these approaches, 3D surfaces are mainly reconstructed based on dense matching techniques. However, generated 3D point clouds might not accurately represent the scanned surfaces due to point density variations and edge preservation problems. In order to resolve these problems, a new region-based 3D surface renostruction trchnique is introduced in this paper. This approach aims to generate a 3D photo-realistic model of individually scanned surfaces within the captured images. This approach is initiated by a Semi-Global dense Matching procedure is carried out to generate a 3D point cloud from the scanned area within the collected images. The generated point cloud is then segmented to extract individual planar surfaces. Finally, a novel region-based texturing technique is implemented for photorealistic reconstruction of the extracted planar surfaces. Experimental results using images collected by a camera mounted on a low-cost UAS demonstrate the feasibility of the proposed approach for photorealistic 3D surface reconstruction.

  18. REGION-BASED 3D SURFACE RECONSTRUCTION USING IMAGES ACQUIRED BY LOW-COST UNMANNED AERIAL SYSTEMS

    Directory of Open Access Journals (Sweden)

    Z. Lari

    2015-08-01

    Full Text Available Accurate 3D surface reconstruction of our environment has become essential for an unlimited number of emerging applications. In the past few years, Unmanned Aerial Systems (UAS are evolving as low-cost and flexible platforms for geospatial data collection that could meet the needs of aforementioned application and overcome limitations of traditional airborne and terrestrial mobile mapping systems. Due to their payload restrictions, these systems usually include consumer-grade imaging and positioning sensor which will negatively impact the quality of the collected geospatial data and reconstructed surfaces. Therefore, new surface reconstruction surfaces are needed to mitigate the impact of using low-cost sensors on the final products. To date, different approaches have been proposed to for 3D surface construction using overlapping images collected by imaging sensor mounted on moving platforms. In these approaches, 3D surfaces are mainly reconstructed based on dense matching techniques. However, generated 3D point clouds might not accurately represent the scanned surfaces due to point density variations and edge preservation problems. In order to resolve these problems, a new region-based 3D surface renostruction trchnique is introduced in this paper. This approach aims to generate a 3D photo-realistic model of individually scanned surfaces within the captured images. This approach is initiated by a Semi-Global dense Matching procedure is carried out to generate a 3D point cloud from the scanned area within the collected images. The generated point cloud is then segmented to extract individual planar surfaces. Finally, a novel region-based texturing technique is implemented for photorealistic reconstruction of the extracted planar surfaces. Experimental results using images collected by a camera mounted on a low-cost UAS demonstrate the feasibility of the proposed approach for photorealistic 3D surface reconstruction.

  19. The Avignon Bridge: a 3d Reconstruction Project Integrating Archaeological, Historical and Gemorphological Issues

    Science.gov (United States)

    Berthelot, M.; Nony, N.; Gugi, L.; Bishop, A.; De Luca, L.

    2015-02-01

    The history and identity of the Avignon's bridge is inseparable from that of the Rhône river. Therefore, in order to share the history and memory of the Rhône, it is essential to get to know this bridge and especially to identify and make visible the traces of its past, its construction, its interaction with the river dynamics, which greatly influenced his life. These are the objectives of the PAVAGE project that focuses on digitally surveying, modelling and re-visiting a heritage site of primary importance with the aim of virtually restoring the link between the two sides which, after the disappearance of the Roman bridge of Arles, constituted for a long time the only connection between Lyon or Vienna and the sea. Therefore, this project has an important geo-historical dimension for which geo-morphological and paleoenvironmental studies were implemented in connection with the latest digital simulation methods exploiting geographic information systems. By integrating knowledge and reflections of archaeologists, historians, geomorphologists, environmentalists, architects, engineers and computer scientists, the result of this project (which involved 5 laboratories during 4 years) is a 3D digital model covering an extension of 50 km2 achieved by integrating satellite imagery, UAV-based acquisitions, terrestrial laser scanning and photogrammetry, etc. Beyond the actions of scientific valorisation concerning the historical and geomorphological dimensions of the project, the results of this work of this interdisciplinary investigation and interpretation of this site are today integrated within a location-based augmented reality application allowing tourists to exploring the virtual reconstruction of the bridge and its environment through tablets inside the portion of territory covered by this project (between Avignon and Villeneuve-lez-Avignon). This paper presents the main aspects of the 3D virtual reconstruction approach.

  20. 3D Reconstruction of Human Laryngeal Dynamics Based on Endoscopic High-Speed Recordings.

    Science.gov (United States)

    Semmler, Marion; Kniesburges, Stefan; Birk, Veronika; Ziethe, Anke; Patel, Rita; Dollinger, Michael

    2016-07-01

    Standard laryngoscopic imaging techniques provide only limited two-dimensional insights into the vocal fold vibrations not taking the vertical component into account. However, previous experiments have shown a significant vertical component in the vibration of the vocal folds. We present a 3D reconstruction of the entire superior vocal fold surface from 2D high-speed videoendoscopy via stereo triangulation. In a typical camera-laser set-up the structured laser light pattern is projected on the vocal folds and captured at 4000 fps. The measuring device is suitable for in vivo application since the external dimensions of the miniaturized set-up barely exceed the size of a standard rigid laryngoscope. We provide a conservative estimate on the resulting resolution based on the hardware components and point out the possibilities and limitations of the miniaturized camera-laser set-up. In addition to the 3D vocal fold surface, we extended previous approaches with a G2-continuous model of the vocal fold edge. The clinical applicability was successfully established by the reconstruction of visual data acquired from 2D in vivo high-speed recordings of a female and a male subject. We present extracted dynamic parameters like maximum amplitude and velocity in the vertical direction. The additional vertical component reveals deeper insights into the vibratory dynamics of the vocal folds by means of a non-invasive method. The successful miniaturization allows for in vivo application giving access to the most realistic model available and hence enables a comprehensive understanding of the human phonation process. PMID:26829782

  1. Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

    Science.gov (United States)

    Lorintiu, Oana; Liebgott, Hervé; Alessandrini, Martino; Bernard, Olivier; Friboulet, Denis

    2015-12-01

    In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of images such as US images. In this study, the dictionary was learned using the K-SVD algorithm and CS reconstruction was performed on the non-log envelope data by removing 20% to 80% of the original data. Using numerically simulated images, we evaluate the influence of the training parameters and of the sampling strategy. The latter is done by comparing the two most common sampling patterns, i.e., point-wise and line-wise random patterns. The results show in particular that line-wise sampling yields an accuracy comparable to the conventional point-wise sampling. This indicates that CS acquisition of 3D data is feasible in a relatively simple setting, and thus offers the perspective of increasing the frame rate by skipping the acquisition of RF lines. Next, we evaluated this approach on US volumes of several ex vivo and in vivo organs. We first show that the learned dictionary approach yields better performances than conventional fixed transforms such as Fourier or discrete cosine. Finally, we investigate the generality of the learned dictionary approach and show that it is possible to build a general dictionary allowing to reliably reconstruct different volumes of different ex vivo or in vivo organs.

  2. 3D Surface Reconstruction of Rills in a Spanish Olive Grove

    Science.gov (United States)

    Brings, Christine; Gronz, Oliver; Seeger, Manuel; Wirtz, Stefan; Taguas, Encarnación; Ries, Johannes B.

    2016-04-01

    The low-cost, user-friendly photogrammetric Structure from Motion (SfM) technique is used for 3D surface reconstruction and difference calculation of an 18 meter long rill in South Spain (Andalusia, Puente Genil). The images were taken with a Canon HD video camera before and after a rill experiment in an olive grove. Recording with a video camera has compared to a photo camera a huge time advantage and the method also guarantees more than adequately overlapping sharp images. For each model, approximately 20 minutes of video were taken. As SfM needs single images, the sharpest image was automatically selected from 8 frame intervals. The sharpness was estimated using a derivative-based metric. Then, VisualSfM detects feature points in each image, searches matching feature points in all image pairs and recovers the camera and feature positions. Finally, by triangulation of camera positions and feature points the software reconstructs a point cloud of the rill surface. From the point cloud, 3D surface models (meshes) are created and via difference calculations of the pre and post model a visualization of the changes (erosion and accumulation areas) and quantification of erosion volumes are possible. The calculated volumes are presented in spatial units of the models and so real values must be converted via references. The results show that rills in olive groves have a high dynamic due to the lack of vegetation cover under the trees, so that the rill can incise until the bedrock. Another reason for the high activity is the intensive employment of machinery.

  3. Reconstructing the Vulcano Island evolution from 3D modeling of magnetic signatures

    Science.gov (United States)

    Napoli, Rosalba; Currenti, Gilda

    2016-06-01

    High-resolution ground and marine magnetic data are exploited for a detailed definition of a 3D model of the Vulcano Island volcanic complex. The resulting 3D magnetic imaging, obtained by 3-D inverse modeling technique, has delivered useful constraints both to reconstruct the Vulcano Island evolution and to be used as input data for volcanic hazard assessment models. Our results constrained the depth and geometry of the main geo-structural features revealing more subsurface volcanic structures than exposed ones and allowing to elucidate the relationships between them. The recognition of two different magnetization sectors, approximatively coincident with the structural depressions of Piano caldera, in the southern half of the island, and La Fossa caldera at the north, suggests a complex structural and volcanic evolution. Magnetic highs identified across the southern half of the island reflect the main crystallized feeding systems, intrusions and buried vents, whose NNW-SSE preferential alignment highlights the role of the NNW-SSE Tindari-Letojanni regional system from the initial activity of the submarine edifice, to the more recent activity of the Vulcano complex. The low magnetization area, in the middle part of the island may result from hydrothermally altered rocks. Their presence not only in the central part of the volcano edifice but also in other peripheral areas, is a sign of a more diffuse historical hydrothermal activity than in present days. Moreover, the high magnetization heterogeneity within the upper flanks of La Fossa cone edifice is an imprint of a composite distribution of unaltered and altered rocks with different mechanical properties, which poses in this area a high risk level for failure processes especially during volcanic or hydrothermal crisis.

  4. GPU accelerated generation of digitally reconstructed radiographs for 2-D/3-D image registration.

    Science.gov (United States)

    Dorgham, Osama M; Laycock, Stephen D; Fisher, Mark H

    2012-09-01

    Recent advances in programming languages for graphics processing units (GPUs) provide developers with a convenient way of implementing applications which can be executed on the CPU and GPU interchangeably. GPUs are becoming relatively cheap, powerful, and widely available hardware components, which can be used to perform intensive calculations. The last decade of hardware performance developments shows that GPU-based computation is progressing significantly faster than CPU-based computation, particularly if one considers the execution of highly parallelisable algorithms. Future predictions illustrate that this trend is likely to continue. In this paper, we introduce a way of accelerating 2-D/3-D image registration by developing a hybrid system which executes on the CPU and utilizes the GPU for parallelizing the generation of digitally reconstructed radiographs (DRRs). Based on the advancements of the GPU over the CPU, it is timely to exploit the benefits of many-core GPU technology by developing algorithms for DRR generation. Although some previous work has investigated the rendering of DRRs using the GPU, this paper investigates approximations which reduce the computational overhead while still maintaining a quality consistent with that needed for 2-D/3-D registration with sufficient accuracy to be clinically acceptable in certain applications of radiation oncology. Furthermore, by comparing implementations of 2-D/3-D registration on the CPU and GPU, we investigate current performance and propose an optimal framework for PC implementations addressing the rigid registration problem. Using this framework, we are able to render DRR images from a 256×256×133 CT volume in ~24 ms using an NVidia GeForce 8800 GTX and in ~2 ms using NVidia GeForce GTX 580. In addition to applications requiring fast automatic patient setup, these levels of performance suggest image-guided radiation therapy at video frame rates is technically feasible using relatively low cost PC

  5. Towards the Next Generation Upper-Mantle 3D Anelastic Tomography

    Science.gov (United States)

    Karaoglu, H.; Romanowicz, B. A.

    2015-12-01

    In order to distinguish the thermal and compositional heterogeneities in the mantle, it is crucial to resolve the lateral variations not only in seismic velocities but also in intrinsic attenuation. Indeed, the high sensitivity of intrinsic attenuation to temperature and water content, governed by a form of Arrhenius equation, contrasts with the quasi-linear dependence of velocities on both temperature and major element composition. The major challenge in imaging attenuation lies in separating its effects on seismic waves from the elastic ones. The latter originate from the wave propagation in media with strong lateral elastic gradients causing (de)focusing and scattering. We have previously developed a 3D upper-mantle shear attenuation model based on time domain waveform inversion of long period (T > 60s) fundamental and overtone surface wave data (Gung & Romanowicz, 2004). However, at that time, resolution was limited to very long wavelength structure, because elastic models were still rather smooth, and the effects of focusing could only be estimated approximately, using asymptotic normal mode perturbation theory.With recent progress in constraining global mantle shear velocity from waveform tomography based on the Spectral Element Method (e.g. SEMUCB_WM1, French & Romanowicz, 2014), we are now in a position to develop an improved global 3D model of shear attenuation in the upper mantle. In doing so, we use a similar time domain waveform inversion approach, but (1) start with a higher resolution elastic model with better constraints on lateral elastic gradients and (2) jointly invert, in an iterative fashion, for shear attenuation and elastic parameters. Here, we present the results of synthetic tests that confirm our inversion strategy, as well as preliminary results towards the construction of the next generation upper-mantle anelastic model.

  6. 3D Reconstruction of the Vortex in a Human Right Ventricle Model using High Speed PIV

    Science.gov (United States)

    Kheradvar, Arash; Falahatpisheh, Ahmad

    2011-11-01

    This work aims to characterize the formation process and translation of the vortex, which forms along with the trans-tricuspid jet in a realistic model of a human right ventricle (RV). A clear model of the RV made of silicone rubber was carefully casted in real size from echocardiographic data of an adult human heart. The RV model was used in our heart pulsed-flow simulator at KLAB at UCI to perform experiments. Bioprosthetic heart valves in appropriate sizes were used at tricuspid and pulmonary positions. Multi-planar high-speed PIV was performed to capture and reconstruct the 3D flow field with a 1-millisecond time gap between each two velocity frames. λ2 iso-surfaces were used to illustrate the evolution of vortex cores. The highly asymmetric shape of the RV chamber results in a complex 3D trans-tricuspid vortex that forms and translates toward right ventricular outflow tract, and finally departs RV from pulmonary valve. Through this study, -for the first time- the formation, evolution and pathway of the RV vortex have been characterized in vitro.

  7. Ion track reconstruction in 3D using alumina-based fluorescent nuclear track detectors

    CERN Document Server

    Niklas, Martin; Akselrod, Mark S; Abollahi, Amir; Jäkel, Oliver; Greilich, Steffen

    2013-01-01

    Fluorescent nuclear track detectors (FNTDs) based on Al2O3:C,Mg single crystal combined with confocal microscopy provide 3D information on ion tracks with a resolution only limited by light diffraction. FNTDs are also ideal substrates to be coated with cells to engineer cell-fluorescent ion track hybrid detectors. This radiobiological tool enables a novel platform linking cell responses to physical dose deposition on a sub-cellular level in proton and heavy ion therapies. To achieve spatial correlation between single ion hits in the cell coating and its biological response the ion traversals have to be reconstructed in 3D using the depth information gained by the FNTD read-out. FNTDs were coated with a confluent human lung adenocarcinoma epithelial cell layer. Carbon ion irradiation of the hybrid detector was performed perpendicular and angular to the detector surface. In-situ imaging of the fluorescently labeled cell layer and the FNTD was performed in a sequential read-out. Making use of the trajectory info...

  8. Computational 3D reconstructions by optimization for cryo-electron microscopy

    Science.gov (United States)

    Yin, Zhye; Zheng, Yili; Doerschuk, Peter C.; Johnson, John E.

    2003-06-01

    An algorithm for the simultaneous 3-D reconstruction of several types of object, where each type of object may possibly have a rotational symmetry, from 2-D projection images, where for each image the type of object imaged, the projection orientation used to create the image, and the location of the object in the image are unknown, is described. The motivating application is the determination of the 3-D structure of small spherical viruses from cryo electron microscopy images. The algorithm is a maximum likelihood estimator which is computed by expectation maximization (EM). Due to the structure of the statistical model, the maximization step of EM can be easily computed but the expectation step requires 5-D numerical quadrature. The computational burden of the quadratures necessitates parallel computation and three different implementations of two different types of parallelism have been developed using pthreads (for shared memory processors) and MPI (for distributed memory processors). An example applying one of the MPI implementations, running on a 32 node PC cluster, to experimental images of Flock House Virus with comparison to the x-ray crystal diffraction structure of the virus is described.

  9. Introduction to 3D reconstruction of macromolecules using single particle electron microscopy

    Institute of Scientific and Technical Information of China (English)

    Oscar LLORCA

    2005-01-01

    Single-particle electron microscopy has now reached maturity, becoming a commonly used method in the examination ofmacromolecular structure. Using a small amount of purified protein, isolated molecules are observed under the electron microscope and the data collected can be averaged into a 3D reconstruction.Single-particle electron microscopy is an appropriate tool for the analysis of proteins that can only be obtained in modest quantities, like many of the large complexes currently of interest in biomedicine. Whilst the use of electron microscopy expands, new methods are being developed and improved to deal with further challenges, such as reaching higher resolutions and the combination of information at different levels of structural detail. More importantly, present methodology is still not robust enough when studying certain "tricky" proteins like those displaying extensive conformational flexibility and a great deal of user expertise is required, posing a threat to the consistency of the final structure. This mini review describes a brief outline of the methods currently used in the 3D analysis of macromolecules using single-particle electron microscopy, intended for those first approaching this field. A summary of methods, techniques, software, and some recent work is presented. The spectacular improvements to the technique in recent years, its advantages and limitations compared to other structural methods,and its future developments are discussed.

  10. Semi-automated 3D leaf reconstruction and analysis of trichome patterning from light microscopic images.

    Directory of Open Access Journals (Sweden)

    Henrik Failmezger

    2013-04-01

    Full Text Available Trichomes are leaf hairs that are formed by single cells on the leaf surface. They are known to be involved in pathogen resistance. Their patterning is considered to emerge from a field of initially equivalent cells through the action of a gene regulatory network involving trichome fate promoting and inhibiting factors. For a quantitative analysis of single and double mutants or the phenotypic variation of patterns in different ecotypes, it is imperative to statistically evaluate the pattern reliably on a large number of leaves. Here we present a method that enables the analysis of trichome patterns at early developmental leaf stages and the automatic analysis of various spatial parameters. We focus on the most challenging young leaf stages that require the analysis in three dimensions, as the leaves are typically not flat. Our software TrichEratops reconstructs 3D surface models from 2D stacks of conventional light-microscope pictures. It allows the GUI-based annotation of different stages of trichome development, which can be analyzed with respect to their spatial distribution to capture trichome patterning events. We show that 3D modeling removes biases of simpler 2D models and that novel trichome patterning features increase the sensitivity for inter-accession comparisons.

  11. Access to the kinematic information for the velocity model determination by 3-D reflexion tomography; Acces a l'information cinematique pour la determination du modele de vitesse par tomographie de reflexion 3D

    Energy Technology Data Exchange (ETDEWEB)

    Broto, K.

    1999-04-01

    The access to a reliable image of the subsurface requires a kinematically correct velocity depth model.Reflection tomography allows to meet this requirement if a complete and coherent pre-stack kinematic database can be provided. However, in case of complex sub-surfaces, wave propagation may lead to hardly interpretable seismic events in the time data. The SMART method is a sequential method that relies on reflection tomography for updating the velocity model and on the pre-stack depth migrated domain for extracting kinematic information that is not readily accessible in the time domain. For determining 3-D subsurface velocity models in case of complex structures, we propose the seriated SMART 2-D method as an alternative to the currently inconceivable SMART 3-D method. In order to extract kinematic information from a 3-D pre-stack data set, we combine detours through the 2-D pre-stack depth domain for a number of selected lines of the studied 3-D survey and 3-D reflection tomography for updating the velocity model. The travel-times from the SMART method being independent of the velocity model used for passing through the pre-stack depth migrated domain, the access to 3-D travel-times is ensured, even if they have been obtained via a 2-D domain. Besides, we propose to build a kinematical guide for ensuring the coherency of the seriated 2-D pre-stack depth interpretations and the access to a complete 3-D pre-stack kinematic database when dealing with structures associated with 3-D wave propagation. We opt for a blocky representation of the velocity model in order to be able to cope with complex structures. This representation leads us to define specific methodological rules for carrying out the different steps of the seriated SMART 2-D method. We also define strategies, built from the analysis of first inversion results, for an efficient application of reflection tomography. Besides, we discuss the problem of uncertainties to be assigned to travel-times obtained

  12. Non-linear 3-D Born shear waveform tomography in Southeast Asia

    Science.gov (United States)

    Panning, Mark P.; Cao, Aimin; Kim, Ahyi; Romanowicz, Barbara A.

    2012-07-01

    Southeast (SE) Asia is a tectonically complex region surrounded by many active source regions, thus an ideal test bed for developments in seismic tomography. Much recent development in tomography has been based on 3-D sensitivity kernels based on the first-order Born approximation, but there are potential problems with this approach when applied to waveform data. In this study, we develop a radially anisotropic model of SE Asia using long-period multimode waveforms. We use a theoretical 'cascade' approach, starting with a large-scale Eurasian model developed using 2-D Non-linear Asymptotic Coupling Theory (NACT) sensitivity kernels, and then using a modified Born approximation (nBorn), shown to be more accurate at modelling waveforms, to invert a subset of the data for structure in a subregion (longitude 75°-150° and latitude 0°-45°). In this subregion, the model is parametrized at a spherical spline level 6 (˜200 km). The data set is also inverted using NACT and purely linear 3-D Born kernels. All three final models fit the data well, with just under 80 per cent variance reduction as calculated using the corresponding theory, but the nBorn model shows more detailed structure than the NACT model throughout and has much better resolution at depths greater than 250 km. Based on variance analysis, the purely linear Born kernels do not provide as good a fit to the data due to deviations from linearity for the waveform data set used in this modelling. The nBorn isotropic model shows a stronger fast velocity anomaly beneath the Tibetan Plateau in the depth range of 150-250 km, which disappears at greater depth, consistent with other studies. It also indicates moderate thinning of the high-velocity plate in the middle of Tibet, consistent with a model where Tibet is underplated by Indian lithosphere from the south and Eurasian lithosphere from the north, in contrast to a model with continuous underplating by Indian lithosphere across the entire plateau. The n

  13. A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenyang [Department of Bioengineering, University of California, Los Angeles, California 90095 (United States); Cheung, Yam; Sabouri, Pouya; Arai, Tatsuya J.; Sawant, Amit [Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas 75390 (United States); Ruan, Dan, E-mail: druan@mednet.ucla.edu [Department of Bioengineering, University of California, Los Angeles, California 90095 and Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States)

    2015-11-15

    achieved submillimeter reconstruction RMSE under different configurations, demonstrating quantitatively the faith of the proposed method in preserving local structural properties of the underlying surface in the presence of noise and missing measurements, and its robustness toward variations of such characteristics. On point clouds from the human subject, the proposed method successfully reconstructed all patient surfaces, filling regions where raw point coordinate readings were missing. Within two comparable regions of interest in the chest area, similar mean curvature distributions were acquired from both their reconstructed surface and CT surface, with mean and standard deviation of (μ{sub recon} = − 2.7 × 10{sup −3} mm{sup −1}, σ{sub recon} = 7.0 × 10{sup −3} mm{sup −1}) and (μ{sub CT} = − 2.5 × 10{sup −3} mm{sup −1}, σ{sub CT} = 5.3 × 10{sup −3} mm{sup −1}), respectively. The agreement of local geometry properties between the reconstructed surfaces and the CT surface demonstrated the ability of the proposed method in faithfully representing the underlying patient surface. Conclusions: The authors have integrated and developed an accurate level-set based continuous surface reconstruction method on point clouds acquired by a 3D surface photogrammetry system. The proposed method has generated a continuous representation of the underlying phantom and patient surfaces with good robustness against noise and missing measurements. It serves as an important first step for further development of motion tracking methods during radiotherapy.

  14. The `L' Array, a method to model 3D Electrical Resistivity Tomography (ERT) data

    Science.gov (United States)

    Chavez Segura, R. E.; Chavez-Hernandez, G.; Delgado, C.; Tejero-Andrade, A.

    2010-12-01

    The electrical resistivity tomography (ERT) is a method designed to calculate the distribution of apparent electrical resistivities in the subsoil by means of a great number of observations with the aim of determining an electrical image displaying the distribution of true resistivities in the subsoil. Such process can be carried out to define 2D or 3D models of the subsurface. For a 3D ERT, usually, the electrodes are placed in a squared grid keeping the distance between adjacent electrodes constant in the x and y directions. Another design employed, consists of a series of parallel lines whose space inter-lines must be smaller or equal to four times the electrode separation. The most common electrode arrays frequently employed for this type of studies are the pole-pole, pole-dipole and dipole-dipole. Unfortunately, ERT surface sampling schemes are limited by physical conditions or obstacles, like buildings, highly populated urban zones, and geologic/topographic features, where the lines of electrodes cannot be set. However, it is always necessary to characterize the subsoil beneath such anthropogenic or natural features. The ‘L’ shaped array has the main purpose to overcome such difficulties by surrounding the study area with a square of electrode lines. The measurements are obtained by switching automatically current and potential electrodes from one line to the other. Each observation adds a level of information, from one profile to the other. Once the total levels of data are completed, the opposite ‘L’ array can be measured following the same process. The complete square is computed after the parallel profiles are observed as well. At the end, the computed resistivities are combined to form a 3D matrix of observations. Such set of data can be inverted to obtain the true resistivity distribution at depth in the form of a working cube, which can be interpreted. The method was tested with theoretical models, which included a set of two resistive cubes

  15. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience; Angiotomografia computadorizada de coronarias com tomografo com 320 fileiras de detectores e utilizando o AIDR-3D: experiencia inicial

    Energy Technology Data Exchange (ETDEWEB)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao, E-mail: roberto.neto@einstein.br [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil); Failla, Bruna Bonaventura [Universidade Metodista de Sao Paulo, Sao Bernardo do Campo, SP (Brazil)

    2013-07-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  16. CT scans and 3D reconstructions of Florida manatee (Trichechus manatus latirostris) heads and ear bones.

    Science.gov (United States)

    Chapla, Marie E; Nowacek, Douglas P; Rommel, Sentiel A; Sadler, Valerie M

    2007-06-01

    The auditory anatomy of the Florida manatee (Trichechus manatus latirostris) was investigated using computerized tomography (CT), three-dimensional reconstructions, and traditional dissection of heads removed during necropsy. The densities (kg/m3) of the soft tissues of the head were measured directly using the displacement method and those of the soft tissues and bone were calculated from CT measurements (Hounsfield units). The manatee's fatty tissue was significantly less dense than the other soft tissues within the head (p<0.05). The squamosal bone was significantly less dense than the other bones of the head (p<0.05). Measurements of the ear bones (tympanic, periotic, malleus, incus, and stapes) collected during dissection revealed that the ossicular chain was overly massive for the mass of the tympanoperiotic complex. PMID:17420106

  17. 3D reconstruction of single rising bubble in water using digital image processing and characteristic matrix

    Institute of Scientific and Technical Information of China (English)

    Yuchen Bian; Feng Dong; Weida Zhang; Hongyi Wang; Chao Tan; Zhiqiang Zhang

    2013-01-01

    Reconstructing the shape of a bubble will lay a firm foundation for further description of the dynamic characteristics of bubbly flow,especially for a single rising bubble or separate bubbles whose interaction could be neglected.In this case,the rising bubble is usually simulated as an ellipsoid consisting of two semi-ellipsoids up and down.Thus the projected image of a bubble consists of two semi-ellipses.In this paper,a method for reconstructing the ellipsoid bubble model is described following digital image processing,using the Hough transform in 2D ellipse parameter extraction which could cover most of the bubble edge points in the image.Then a method based on characteristic symmetric matrix is described to detect 3D bubble ellipsoid model parameters from 2D ellipse parameters of projection planes.This method can be applied to bubbles rising with low-velocity in static flow field much in conformity with the projection theory and the shape variation of the rising bubble.This method does not need to solve nonlinear equation sets and provides an easy way to calculate the characteristic matrix of a space ellipsoid model for deformed bubble.For bubble application,two assumed conditions and a calibration factor are proposed to simplify calculation and detection.Errors of ellipsoid center and three axes are minor.Errors of the three rotation angles have no negative effect on further study on bubbly flow.

  18. Processing of MRI images weighted in TOF for blood vessels analysis: 3-D reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez D, J.; Cordova F, T. [Universidad de Guanajuato, Campus Leon, Departamento de Ingenieria Fisica, Loma del Bosque No. 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Cruz A, I., E-mail: hernandezdj.gto@gmail.com [CONACYT, Centro de Investigacion en Matematicas, A. C., Jalisco s/n, Col. Valenciana, 36000 Guanajuato, Gto. (Mexico)

    2015-10-15

    This paper presents a novel presents an approach based on differences of intensities for the identification of vascular structures in medical images from MRI studies of type time of flight method (TOF). The plating method hypothesis gave high intensities belonging to the vascular system image type TOF can be segmented by thresholding of the histogram. The enhanced vascular structures is performed using the filter Vesselness, upon completion of a decision based on fuzzy thresholding minimizes error in the selection of vascular structures. It will give a brief introduction to the vascular system problems and how the images have helped diagnosis, is summarized the physical history of the different imaging modalities and the evolution of digital images with computers. Segmentation and 3-D reconstruction became image type time of flight; these images are typically used in medical diagnosis of cerebrovascular diseases. The proposed method has less error in segmentation and reconstruction of volumes related to the vascular system, clear images and less noise compared with edge detection methods. (Author)

  19. 3D cardiac motion reconstruction from CT data and tagged MRI.

    Science.gov (United States)

    Wang, Xiaoxu; Mihalef, Viorel; Qian, Zhen; Voros, Szilard; Metaxas, Dimitris

    2012-01-01

    In this paper we present a novel method for left ventricle (LV) endocardium motion reconstruction using high resolution CT data and tagged MRI. High resolution CT data provide anatomic details on the LV endocardial surface, such as the papillary muscle and trabeculae carneae. Tagged MRI provides better time resolution. The combination of these two imaging techniques can give us better understanding on left ventricle motion. The high resolution CT images are segmented with mean shift method and generate the LV endocardium mesh. The meshless deformable model built with high resolution endocardium surface from CT data fit to the tagged MRI of the same phase. 3D deformation of the myocardium is computed with the Lagrangian dynamics and local Laplacian deformation. The segmented inner surface of left ventricle is compared with the heart inner surface picture and show high agreement. The papillary muscles are attached to the inner surface with roots. The free wall of the left ventricle inner surface is covered with trabeculae carneae. The deformation of the heart wall and the papillary muscle in the first half of the cardiac cycle is presented. The motion reconstruction results are very close to the live heart video. PMID:23366825

  20. 3D building reconstruction from ALS data using unambiguous decomposition into elementary structures

    Science.gov (United States)

    Jarząbek-Rychard, M.; Borkowski, A.

    2016-08-01

    The objective of the paper is to develop an automated method that enables for the recognition and semantic interpretation of topological building structures. The novelty of the proposed modeling approach is an unambiguous decomposition of complex objects into predefined simple parametric structures, resulting in the reconstruction of one topological unit without independent overlapping elements. The aim of a data processing chain is to generate complete polyhedral models at LOD2 with an explicit topological structure and semantic information. The algorithms are performed on 3D point clouds acquired by airborne laser scanning. The presented methodology combines data-based information reflected in an attributed roof topology graph with common knowledge about buildings stored in a library of elementary structures. In order to achieve an appropriate balance between reconstruction precision and visualization aspects, the implemented library contains a set of structure-depended soft modeling rules instead of strictly defined geometric primitives. The proposed modeling algorithm starts with roof plane extraction performed by the segmentation of building point clouds, followed by topology identification and recognition of predefined structures. We evaluate the performance of the novel procedure by the analysis of the modeling accuracy and the degree of modeling detail. The assessment according to the validation methods standardized by the International Society for Photogrammetry and Remote Sensing shows that the completeness of the algorithm is above 80%, whereas the correctness exceeds 98%.

  1. In-line monitoring and reverse 3D model reconstruction in additive manufacturing

    DEFF Research Database (Denmark)

    Pedersen, David Bue; Hansen, Hans Nørgaard; Nielsen, Jakob Skov

    2010-01-01

    Additive manufacturing allows for close-to unrestrained geometrical freedom in part design. The ability to manufacture geometries of such complexity is however limited by the fact that it proves difficult to verify tolerances of these parts. Tolerancs of featuress that are inaccessible with tradi......D printing (3DP), or Selective Laser Sintering (SLS) equipment. The system will be implemented and tested on a 3DP machine with modifications developed at the author's university.......Additive manufacturing allows for close-to unrestrained geometrical freedom in part design. The ability to manufacture geometries of such complexity is however limited by the fact that it proves difficult to verify tolerances of these parts. Tolerancs of featuress that are inaccessible...... with traditional measuring equipment such as Coordinate Measurement Machines (CMM's) can not easily be verified. This paradox is addresses by the proposal of an in-line reverse engineering and 3D reconstruction method that alows for a true to scale reconstruction of a part that is being additivelymanufactures on 3...

  2. 3D PET image reconstruction based on Maximum Likelihood Estimation Method (MLEM) algorithm

    CERN Document Server

    Słomski, Artur; Bednarski, Tomasz; Białas, Piotr; Czerwiński, Eryk; Kapłon, Łukasz; Kochanowski, Andrzej; Korcyl, Grzegorz; Kowal, Jakub; Kowalski, Paweł; Kozik, Tomasz; Krzemień, Wojciech; Molenda, Marcin; Moskal, Paweł; Niedźwiecki, Szymon; Pałka, Marek; Pawlik, Monika; Raczyński, Lech; Salabura, Piotr; Gupta-Sharma, Neha; Silarski, Michał; Smyrski, Jerzy; Strzelecki, Adam; Wiślicki, Wojciech; Zieliński, Marcin; Zoń, Natalia

    2015-01-01

    Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines connecting two detectors. As there is a multitude of detectors build-in typical PET tomograph structure, there are many possible detector pairs that pertain to the measurement. The problem is how to turn this measurement into an image (this is called imaging). Decisive improvement in PET image quality was reached with the introduction of iterative reconstruction techniques. This stage was reached already twenty years ago (with the advent of new powerful computing processors). However, three dimensional (3D) imaging remains still a challenge. The purpose of the image reconstruction algorithm is to process this imperfect count data for a large number (many millions) of lines-of-responce (LOR) and millions of detected photons to produce an image showing the distribution of the l...

  3. Reducing computational costs in large scale 3D EIT by using a sparse Jacobian matrix with block-wise CGLS reconstruction

    International Nuclear Information System (INIS)

    Electrical impedance tomography (EIT) is a fast and cost-effective technique to provide a tomographic conductivity image of a subject from boundary current–voltage data. This paper proposes a time and memory efficient method for solving a large scale 3D EIT inverse problem using a parallel conjugate gradient (CG) algorithm. The 3D EIT system with a large number of measurement data can produce a large size of Jacobian matrix; this could cause difficulties in computer storage and the inversion process. One of challenges in 3D EIT is to decrease the reconstruction time and memory usage, at the same time retaining the image quality. Firstly, a sparse matrix reduction technique is proposed using thresholding to set very small values of the Jacobian matrix to zero. By adjusting the Jacobian matrix into a sparse format, the element with zeros would be eliminated, which results in a saving of memory requirement. Secondly, a block-wise CG method for parallel reconstruction has been developed. The proposed method has been tested using simulated data as well as experimental test samples. Sparse Jacobian with a block-wise CG enables the large scale EIT problem to be solved efficiently. Image quality measures are presented to quantify the effect of sparse matrix reduction in reconstruction results. (paper)

  4. The effect of CT dose on glenohumeral joint congruency measurements using 3D reconstructed patient-specific bone models

    International Nuclear Information System (INIS)

    The study of joint congruency at the glenohumeral joint of the shoulder using computed tomography (CT) and three-dimensional (3D) reconstructions of joint surfaces is an area of significant clinical interest. However, ionizing radiation delivered to patients during CT examinations is much higher than other types of radiological imaging. The shoulder represents a significant challenge for this modality as it is adjacent to the thyroid gland and breast tissue. The objective of this study was to determine the optimal CT scanning techniques that would minimize radiation dose while accurately quantifying joint congruency of the shoulder. The results suggest that only one-tenth of the standard applied total current (mA) and a pitch ratio of 1.375:1 was necessary to produce joint congruency values consistent with that of the higher dose scans. Using the CT scanning techniques examined in this study, the effective dose applied to the shoulder to quantify joint congruency was reduced by 88.9% compared to standard clinical CT imaging techniques.

  5. The effect of CT dose on glenohumeral joint congruency measurements using 3D reconstructed patient-specific bone models

    Energy Technology Data Exchange (ETDEWEB)

    Lalone, Emily A; Fox, Anne-Marie V; Jenkyn, Thomas R; King, Graham J W; Johnson, James A; Peters, Terry M [Biomedical Engineering, University of Western Ontario, London (Canada); Kedgley, Angela E [Wolf Orthopaedic Biomechanics Lab, Fowler Kennedy Sports Medicine Clinic, London (Canada); Athwal, George S, E-mail: tpeters@robarts.ca [Hand and Upper Limb Centre, St. Joseph' s Hospital, London, Canada (CT Scanning Location) (Canada)

    2011-10-21

    The study of joint congruency at the glenohumeral joint of the shoulder using computed tomography (CT) and three-dimensional (3D) reconstructions of joint surfaces is an area of significant clinical interest. However, ionizing radiation delivered to patients during CT examinations is much higher than other types of radiological imaging. The shoulder represents a significant challenge for this modality as it is adjacent to the thyroid gland and breast tissue. The objective of this study was to determine the optimal CT scanning techniques that would minimize radiation dose while accurately quantifying joint congruency of the shoulder. The results suggest that only one-tenth of the standard applied total current (mA) and a pitch ratio of 1.375:1 was necessary to produce joint congruency values consistent with that of the higher dose scans. Using the CT scanning techniques examined in this study, the effective dose applied to the shoulder to quantify joint congruency was reduced by 88.9% compared to standard clinical CT imaging techniques.

  6. A 3D photogrammetric reconstruction attempt of specimens of Badenian echinoids

    Science.gov (United States)

    Polonkai, Bálint; Raveloson, Andrea; Görög, Ágnes; Bodor, Emese; Székely, Balázs

    2016-04-01

    The rich echinoid fauna of the Badenian (Middle Miocene) from Budapest (Hungary) is well known for more than one hundred years. Along the road cuts and due to the construction of large buildings from 1960 to 2011, new Badenian outcrops with rich and well preserved echinoids were found in the city. Thus the main aim of this study was to revise historically collected echinoids (in the collection of Geological and Geophysical Institute of Hungary) from different parts of the city (Örs Vezér Square, Gyakorló Street, Rákos and District of Budafok-Tétény) and to classify the newly collected fossils, moreover to carry out the palaeoenvironmental reconstruction of the different localities. The specimens studied are from the Upper Badenian Leithakalk Formation Rákos Member, which consists of sandy limestone, calcareous loose sandstone with volcanic clast and/or calcarenite without terrigenous or volcanic clast. One of the most common echinoidea in the Badenian, the Parascutella gibbercula DE SERRES, 1829 is well known and researched in both morphological and taxonomic aspects. However there are some intraspecific morphological features that show sharp differences across the specimens: the adapical conical convexity is considerably different between several forms. The petalodium's length/width ratio is also different between many specimens. Other morphological characters for example peristomal and periproctal aperture and the food groove can also be different. These differences within this relatively small area could be determined by ecological conditions (such as substrate, palaeodepth), or can be related to taxonomical or pathological changes. For an appropriate comparison, quantification of these features is necessary. Photogrammetry is in general a useful and well-developed tool to reconstruct 3D surfaces of artefacts (e.g., in archaeology, cultural heritage, and also in palaeontology). In order to evaluate the differences found in P. gibbercula specimens various

  7. Detectability of hepatic tumors during 3D post-processed ultrafast cone-beam computed tomography

    Science.gov (United States)

    Paul, Jijo; Vogl, Thomas J.; Chacko, Annamma

    2015-10-01

    To evaluate hepatic tumor detection using ultrafast cone-beam computed tomography (UCBCT) cross-sectional and 3D post-processed image datasets. 657 patients were examined using UCBCT during hepatic transarterial chemoembolization (TACE), and data were collected retrospectively from January 2012 to September 2014. Tumor detectability, diagnostic ability, detection accuracy and sensitivity were examined for different hepatic tumors using UCBCT cross-sectional, perfusion blood volume (PBV) and UCBCT-MRI (magnetic resonance imaging) fused image datasets. Appropriate statistical tests were used to compare collected sample data. Fused image data showed the significantly higher (all P  color display. Fused image data produced 100% tumor sensitivity due to the simultaneous availability of MRI and UCBCT information during tumor diagnosis. Fused image data produced excellent hepatic tumor sensitivity, detectability and diagnostic ability compared to other datasets assessed. Fused image data is extremely reliable and useful compared to UCBCT cross-sectional or PBV image datasets to depict hepatic tumors during TACE. Partial anatomical visualization on cross-sectional images was compensated by fused image data during tumor diagnosis.

  8. Computed tomography study of VAPEX process in laboratory 3D model

    Energy Technology Data Exchange (ETDEWEB)

    Wu, G.Q.; Kantzas, A. [Calgary Univ., AB (Canada). Tomographic Imaging and Porous Media Laboratory; Salama, D. [Nexen Inc., Calgary, AB (Canada)

    2008-07-01

    This paper provided details of a 3-D laboratory model of the VAPEX process that used computerized tomography (CT) to examine vapour chamber expansion behaviour in longitudinal and radial directions. The model was comprised of an aluminum cylinder with 2 slotted tubes installed inside to act as injection and production wells. Propane was used as a solvent with heavy oil. The results of experiments conducted with the model showed that the V shape vapour chamber expansion pattern predicted by the 2-D model was a localized phenomenon. The dominant characteristic of the vapour chamber was an overriding of the injected solvent at the top of the model. The overriding was attributed to gravity segregation. The study also showed that longitudinal expansion was more significant than upwards expansion during the early stages of the VAPEX process. Oil production performance was then examined using different solvent injection rates. An analysis of the CT images was conducted to obtain model porosity, density, and oil saturation profiles. The study demonstrated that pressure cycles caused oil to be produced intermittently. Oil swelling by solvent gas dissolution was an important recovery mechanism. It was concluded that solvent soaking can be used to recover additional residual oil during the VAPEX process. 19 refs., 1 tab., 24 figs.

  9. Combining 3D Hydraulic Tomography with Tracer Tests for Improved Transport Characterization.

    Science.gov (United States)

    Sanchez-León, E; Leven, C; Haslauer, C P; Cirpka, O A

    2016-07-01

    Hydraulic tomography (HT) is a method for resolving the spatial distribution of hydraulic parameters to some extent, but many details important for solute transport usually remain unresolved. We present a methodology to improve solute transport predictions by combining data from HT with the breakthrough curve (BTC) of a single forced-gradient tracer test. We estimated the three dimensional (3D) hydraulic-conductivity field in an alluvial aquifer by inverting tomographic pumping tests performed at the Hydrogeological Research Site Lauswiesen close to Tübingen, Germany, using a regularized pilot-point method. We compared the estimated parameter field to available profiles of hydraulic-conductivity variations from direct-push injection logging (DPIL), and validated the hydraulic-conductivity field with hydraulic-head measurements of tests not used in the inversion. After validation, spatially uniform parameters for dual-domain transport were estimated by fitting tracer data collected during a forced-gradient tracer test. The dual-domain assumption was used to parameterize effects of the unresolved heterogeneity of the aquifer and deemed necessary to fit the shape of the BTC using reasonable parameter values. The estimated hydraulic-conductivity field and transport parameters were subsequently used to successfully predict a second independent tracer test. Our work provides an efficient and practical approach to predict solute transport in heterogeneous aquifers without performing elaborate field tracer tests with a tomographic layout.

  10. Passive 3D imaging of nuclear waste containers with Muon Scattering Tomography

    International Nuclear Information System (INIS)

    The non-invasive imaging of dense objects is of particular interest in the context of nuclear waste management, where it is important to know the contents of waste containers without opening them. Using Muon Scattering Tomography (MST), it is possible to obtain a detailed 3D image of the contents of a waste container on reasonable timescales, showing both the high and low density materials inside. We show the performance of such a method on a Monte Carlo simulation of a dummy waste drum object containing objects of different shapes and materials. The simulation has been tuned with our MST prototype detector performance. In particular, we show that both a tungsten penny of 2 cm radius and 1 cm thickness, and a uranium sheet of 0.5 cm thickness can be clearly identified. We also show the performance of a novel edge finding technique, by which the edges of embedded objects can be identified more precisely than by solely using the imaging method

  11. Passive 3D imaging of nuclear waste containers with Muon Scattering Tomography

    Science.gov (United States)

    Thomay, C.; Velthuis, J.; Poffley, T.; Baesso, P.; Cussans, D.; Frazão, L.

    2016-03-01

    The non-invasive imaging of dense objects is of particular interest in the context of nuclear waste management, where it is important to know the contents of waste containers without opening them. Using Muon Scattering Tomography (MST), it is possible to obtain a detailed 3D image of the contents of a waste container on reasonable timescales, showing both the high and low density materials inside. We show the performance of such a method on a Monte Carlo simulation of a dummy waste drum object containing objects of different shapes and materials. The simulation has been tuned with our MST prototype detector performance. In particular, we show that both a tungsten penny of 2 cm radius and 1 cm thickness, and a uranium sheet of 0.5 cm thickness can be clearly identified. We also show the performance of a novel edge finding technique, by which the edges of embedded objects can be identified more precisely than by solely using the imaging method.

  12. Craniosynostosis: prenatal diagnosis by 2D/3D ultrasound, magnetic resonance imaging and computed tomography.

    Science.gov (United States)

    Helfer, Talita Micheletti; Peixoto, Alberto Borges; Tonni, Gabriele; Araujo Júnior, Edward

    2016-09-01

    Craniosynostosis is defined as the process of premature fusion of one or more of the cranial sutures. It is a common condition that occurs in about 1 to 2,000 live births. Craniosynostosis may be classified in primary or secondary. It is also classified as nonsyndromic or syndromic. According to suture commitment, craniosynostosis may affect a single suture or multiple sutures. There is a wide range of syndromes involving craniosynostosis and the most common are Apert, Pffeifer, Crouzon, Shaethre-Chotzen and Muenke syndromes. The underlying etiology of nonsyndromic craniosynostosis is unknown. Mutations in the fibroblast growth factor (FGF) signalling pathway play a crucial role in the etiology of craniosynostosis syndromes. Prenatal ultrasound`s detection rate of craniosynostosis is low. Nowadays, different methods can be applied for prenatal diagnosis of craniosynostosis, such as two-dimensional (2D) and three-dimensional (3D) ultrasound, magnetic resonance imaging (MRI), computed tomography (CT) scan and, finally, molecular diagnosis. The presence of craniosynostosis may affect the birthing process. Fetuses with craniosynostosis also have higher rates of perinatal complications. In order to avoid the risks of untreated craniosynostosis, children are usually treated surgically soon after postnatal diagnosis. PMID:27622416

  13. Detectability of hepatic tumors during 3D post-processed ultrafast cone-beam computed tomography

    International Nuclear Information System (INIS)

    To evaluate hepatic tumor detection using ultrafast cone-beam computed tomography (UCBCT) cross-sectional and 3D post-processed image datasets.657 patients were examined using UCBCT during hepatic transarterial chemoembolization (TACE), and data were collected retrospectively from January 2012 to September 2014. Tumor detectability, diagnostic ability, detection accuracy and sensitivity were examined for different hepatic tumors using UCBCT cross-sectional, perfusion blood volume (PBV) and UCBCT–MRI (magnetic resonance imaging) fused image datasets. Appropriate statistical tests were used to compare collected sample data.Fused image data showed the significantly higher (all P  <  0.05) diagnostic ability for hepatic tumors compared to UCBCT or PBV image data. The detectability of small hepatic tumors (<5 mm) was significantly reduced (all P  <  0.05) using UCBCT cross-sectional images compared to MRI or fused image data; however, PBV improved tumor detectability using a color display. Fused image data produced 100% tumor sensitivity due to the simultaneous availability of MRI and UCBCT information during tumor diagnosis.Fused image data produced excellent hepatic tumor sensitivity, detectability and diagnostic ability compared to other datasets assessed. Fused image data is extremely reliable and useful compared to UCBCT cross-sectional or PBV image datasets to depict hepatic tumors during TACE. Partial anatomical visualization on cross-sectional images was compensated by fused image data during tumor diagnosis. (paper)

  14. Reconstruction of an InAs nanowire using geometric tomography

    DEFF Research Database (Denmark)

    Pennington, Robert S.; König, Stefan; Alpers, Andreas;

    Geometric tomography and conventional algebraic tomography algorithms are used to reconstruct cross-sections of an InAs nanowire from a tilt series of experimental annular dark-field images. Both algorithms are also applied to a test object to assess what factors affect the reconstruction quality...

  15. Spatial decomposition of molecular ions within 3D atom probe reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Andrew [School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Australian Centre for Microscopy and Microanalysis, Madsen Building F09, The University of Sydney, NSW 2006 (Australia); Moody, Michael P. [Department of Materials, University of Oxford, Parks Road, OX13PH, Oxford (United Kingdom); Gault, Baptiste [Department of Materials Science and Engineering, McMaster University, 1280 Main Street West, Hamilton, Ont. L8S4L8 (Canada); Ceguerra, Anna V. [School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Australian Centre for Microscopy and Microanalysis, Madsen Building F09, The University of Sydney, NSW 2006 (Australia); Xie, Kelvin Y. [Johns Hopkins University, Department of Mechanical Engineering, Baltimore, MD 21218 (United States); Du, Sichao [Australian Centre for Microscopy and Microanalysis, Madsen Building F09, The University of Sydney, NSW 2006 (Australia); School of Physics, The University of Sydney, NSW 2006 (Australia); Ringer, Simon P., E-mail: simon.ringer@sydney.edu.au [School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, NSW 2006 (Australia); Australian Centre for Microscopy and Microanalysis, Madsen Building F09, The University of Sydney, NSW 2006 (Australia)

    2013-09-15

    Two methods for separating the constituent atoms of molecular ions within atom probe tomography reconstructions are presented. The Gaussian Separation Method efficiently deconvolutes molecular ions containing two constituent atoms and is tested on simulated data before being applied to an experimental HSLA steel dataset containing NbN. The Delaunay Separation Method extends separation to larger complex ions and is also tested on simulated data before being applied to an experimental GaAs dataset containing many large (>3 atoms) complex ions. First nearest neighbour (1NN) distributions and images of the reconstruction before and after the separations are used to show the effect of the algorithms and their validity and practicality are also discussed. - Highlights: ► The need to deconvolute molecular ions within atom probe data is discussed. ► Two algorithms to separate the constituent atoms of molecular ions are proposed. ► The algorithms developed are tested on simulated and experimental data. ► Nearest neighbour distributions are used to highlight the improvements.

  16. Spatial decomposition of molecular ions within 3D atom probe reconstructions

    International Nuclear Information System (INIS)

    Two methods for separating the constituent atoms of molecular ions within atom probe tomography reconstructions are presented. The Gaussian Separation Method efficiently deconvolutes molecular ions containing two constituent atoms and is tested on simulated data before being applied to an experimental HSLA steel dataset containing NbN. The Delaunay Separation Method extends separation to larger complex ions and is also tested on simulated data before being applied to an experimental GaAs dataset containing many large (>3 atoms) complex ions. First nearest neighbour (1NN) distributions and images of the reconstruction before and after the separations are used to show the effect of the algorithms and their validity and practicality are also discussed. - Highlights: ► The need to deconvolute molecular ions within atom probe data is discussed. ► Two algorithms to separate the constituent atoms of molecular ions are proposed. ► The algorithms developed are tested on simulated and experimental data. ► Nearest neighbour distributions are used to highlight the improvements

  17. Etruscanning 3D project. The 3D reconstruction of the Regolini Galassi Tomb as a research tool and a new approach in storytelling

    Directory of Open Access Journals (Sweden)

    Wim Hupperetz

    2012-11-01

    Full Text Available In the “Etruscanning3D” european project framework, the virtual reconstruction of the Regolini Galassi tomb, in Cerveteri, has been realized, in order to recontextualize its precious funerary goods, today preserved in the vatican Museums, in their ancient space, digitally represented in 3D. The reconstruction has been preceded by a huge work of data collection, reinterpretations, topographical acquisitions through a variety of techniques, digital restorations, in order to create a plausible simulation of how the tomb could appear when it was closed, at the half of the VII century BC. The final purpose of the VR application is communication inside museums, so the narrative approach and the metaphors of interactions played another key role.

  18. Multi-ray-based system matrix generation for 3D PET reconstruction.

    Science.gov (United States)

    Moehrs, Sascha; Defrise, Michel; Belcari, Nicola; Guerra, Alberto Del; Bartoli, Antonietta; Fabbri, Serena; Zanetti, Gianluigi

    2008-12-01

    Iterative image reconstruction algorithms for positron emission tomography (PET) require a sophisticated system matrix (model) of the scanner. Our aim is to set up such a model offline for the YAP-(S)PET II small animal imaging tomograph in order to use it subsequently with standard ML-EM (maximum-likelihood expectation maximization) and OSEM (ordered subset expectation maximization) for fully three-dimensional image reconstruction. In general, the system model can be obtained analytically, via measurements or via Monte Carlo simulations. In this paper, we present the multi-ray method, which can be considered as a hybrid method to set up the system model offline. It incorporates accurate analytical (geometric) considerations as well as crystal depth and crystal scatter effects. At the same time, it has the potential to model seamlessly other physical aspects such as the positron range. The proposed method is based on multiple rays which are traced from/to the detector crystals through the image volume. Such a ray-tracing approach itself is not new; however, we derive a novel mathematical formulation of the approach and investigate the positioning of the integration (ray-end) points. First, we study single system matrix entries and show that the positioning and weighting of the ray-end points according to Gaussian integration give better results compared to equally spaced integration points (trapezoidal integration), especially if only a small number of integration points (rays) are used. Additionally, we show that, for a given variance of the single matrix entries, the number of rays (events) required to calculate the whole matrix is a factor of 20 larger when using a pure Monte-Carlo-based method. Finally, we analyse the quality of the model by reconstructing phantom data from the YAP-(S)PET II scanner. PMID:19001696

  19. Low-amplitude craniofacial EMG power spectral density and 3D muscle reconstruction from MRI

    Directory of Open Access Journals (Sweden)

    Lukas Wiedemann

    2015-03-01

    Full Text Available Improving EEG signal interpretation, specificity, and sensitivity is a primary focus of many current investigations, and the successful application of EEG signal processing methods requires a detailed knowledge of both the topography and frequency spectra of low-amplitude, high-frequency craniofacial EMG. This information remains limited in clinical research, and as such, there is no known reliable technique for the removal of these artifacts from EEG data. The results presented herein outline a preliminary investigation of craniofacial EMG high-frequency spectra and 3D MRI segmentation that offers insight into the development of an anatomically-realistic model for characterizing these effects. The data presented highlights the potential for confounding signal contribution from around 60 to 200 Hz, when observed in frequency space, from both low and high-amplitude EMG signals. This range directly overlaps that of both low γ (30-50 Hz and high γ (50-80 Hz waves, as defined traditionally in standatrd EEG measurements, and mainly with waves presented in dense-array EEG recordings. Likewise, average EMG amplitude comparisons from each condition highlights the similarities in signal contribution of low-activity muscular movements and resting, control conditions. In addition to the FFT analysis performed, 3D segmentation and reconstruction of the craniofacial muscles whose EMG signals were measured was successful. This recapitulation of the relevant EMG morphology is a crucial first step in developing an anatomical model for the isolation and removal of confounding low-amplitude craniofacial EMG signals from EEG data. Such a model may be eventually applied in a clinical setting to ultimately help to extend the use of EEG in various clinical roles.

  20. Low-Amplitude Craniofacial EMG Power Spectral Density and 3D Muscle Reconstruction from MRI.

    Science.gov (United States)

    Wiedemann, Lukas; Chaberova, Jana; Edmunds, Kyle; Einarsdóttir, Guðrún; Ramon, Ceon; Gargiulo, Paolo

    2015-03-11

    Improving EEG signal interpretation, specificity, and sensitivity is a primary focus of many current investigations, and the successful application of EEG signal processing methods requires a detailed knowledge of both the topography and frequency spectra of low-amplitude, high-frequency craniofacial EMG. This information remains limited in clinical research, and as such, there is no known reliable technique for the removal of these artifacts from EEG data. The results presented herein outline a preliminary investigation of craniofacial EMG high-frequency spectra and 3D MRI segmentation that offers insight into the development of an anatomically-realistic model for characterizing these effects. The data presented highlights the potential for confounding signal contribution from around 60 to 200 Hz, when observed in frequency space, from both low and high-amplitude EMG signals. This range directly overlaps that of both low γ (30-50 Hz) and high γ (50-80 Hz) waves, as defined traditionally in standatrd EEG measurements, and mainly with waves presented in dense-array EEG recordings. Likewise, average EMG amplitude comparisons from each condition highlights the similarities in signal contribution of low-activity muscular movements and resting, control conditions. In addition to the FFT analysis performed, 3D segmentation and reconstruction of the craniofacial muscles whose EMG signals were measured was successful. This recapitulation of the relevant EMG morphology is a crucial first step in developing an anatomical model for the isolation and removal of confounding low-amplitude craniofacial EMG signals from EEG data. Such a model may be eventually applied in a clinical setting to ultimately help to extend the use of EEG in various clinical roles.

  1. 3D parallel-detection microwave tomography for clinical breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, N. R., E-mail: nepstein@ucalgary.ca [Schulich School of Engineering, University of Calgary, 2500 University Dr. NW, Calgary, Alberta T2N 1N4 (Canada); Meaney, P. M. [Thayer School of Engineering, Dartmouth College, 14 Engineering Dr., Hanover, New Hampshire 03755 (United States); Paulsen, K. D. [Thayer School of Engineering, Dartmouth College, 14 Engineering Dr., Hanover, New Hampshire 03755 (United States); Department of Radiology, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire 03755 (United States); Norris Cotton Cancer Center, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire 03756 (United States); Advanced Surgical Center, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire 03756 (United States)

    2014-12-15

    A biomedical microwave tomography system with 3D-imaging capabilities has been constructed and translated to the clinic. Updates to the hardware and reconfiguration of the electronic-network layouts in a more compartmentalized construct have streamlined system packaging. Upgrades to the data acquisition and microwave components have increased data-acquisition speeds and improved system performance. By incorporating analog-to-digital boards that accommodate the linear amplification and dynamic-range coverage our system requires, a complete set of data (for a fixed array position at a single frequency) is now acquired in 5.8 s. Replacement of key components (e.g., switches and power dividers) by devices with improved operational bandwidths has enhanced system response over a wider frequency range. High-integrity, low-power signals are routinely measured down to −130 dBm for frequencies ranging from 500 to 2300 MHz. Adequate inter-channel isolation has been maintained, and a dynamic range >110 dB has been achieved for the full operating frequency range (500–2900 MHz). For our primary band of interest, the associated measurement deviations are less than 0.33% and 0.5° for signal amplitude and phase values, respectively. A modified monopole antenna array (composed of two interwoven eight-element sub-arrays), in conjunction with an updated motion-control system capable of independently moving the sub-arrays to various in-plane and cross-plane positions within the illumination chamber, has been configured in the new design for full volumetric data acquisition. Signal-to-noise ratios (SNRs) are more than adequate for all transmit/receive antenna pairs over the full frequency range and for the variety of in-plane and cross-plane configurations. For proximal receivers, in-plane SNRs greater than 80 dB are observed up to 2900 MHz, while cross-plane SNRs greater than 80 dB are seen for 6 cm sub-array spacing (for frequencies up to 1500 MHz). We demonstrate accurate

  2. Advancement of 31P Magnetic Resonance Spectroscopy Using GRAPPA Reconstruction on a 3D Volume

    Science.gov (United States)

    Clevenger, Tony

    The overall objective of this research is to improve currently available metabolic imaging techniques for clinical use in monitoring and predicting treatment response to radiation therapy in liver cancer. Liver metabolism correlates with inflammatory and neoplastic liver diseases, which alter the intracellular concentration of phosphorus- 31 (31P) metabolites [1]. It is assumed that such metabolic changes occur prior to physical changes of the tissue. Therefore, information on regional changes of 31P metabolites in the liver, obtained by Magnetic Resonance Spectroscopic Imaging (MRSI) [1,2], can help in diagnosis and follow-up of various liver diseases. Specifically, there appears to be an immediate need of this technology for both the assessment of tumor response in patients with Hepatocellular Carcinoma (HCC) treated with Stereotactic Body Radiation Therapy (SBRT) [3--5], as well as assessment of radiation toxicity, which can result in worsening liver dysfunction [6]. Pilot data from our lab has shown that 31P MRSI has the potential to identify treatment response five months sooner than conventional methods [7], and to assess the biological response of liver tissue to radiation 24 hours post radiation therapy [8]. While this data is very promising, commonly occurring drawbacks for 31P MRSI are patient discomfort due to long scan times and prone positioning within the scanner, as well as reduced data quality due to patient motion and respiration. To further advance the full potential of 31P MRSI as a clinical diagnostic tool in the management of liver cancer, this PhD research project had the following aims: I) Reduce the long acquisition time of 3D 31P MRS by formulating and imple- menting an appropriate GRAPPA undersampling scheme and reconstruction on a clinical MRI scanner II) Testing and quantitative validation of GRAPPA reconstruction on 3D 31P MRSI on developmental phantoms and healthy volunteers At completion, this work should considerably advance 31P MRSI

  3. Extreme 3D reconstruction of the final ROSETTA/PHILAE landing site

    Science.gov (United States)

    Capanna, Claire; Jorda, Laurent; Lamy, Philippe; Gesquiere, Gilles; Delmas, Cédric; Durand, Joelle; Garmier, Romain; Gaudon, Philippe; Jurado, Eric

    2016-04-01

    The Philae lander aboard the Rosetta spacecraft successfully landed at the surface of comet 67P/Churyumov-Gerasimenko (hereafter 67P/C-G) after two rebounds on November 12, 2014. The final landing site, now known as « Abydos », has been identified on images acquired by the OSIRIS imaging system onboard the Rosetta orbiter[1]. The available images of Abydos are very limited in number and reveal a very extreme topography containing cliffs and overhangs. Furthermore, the surface is only observed under very high incidence angles of 60° on average, which implies that the images also exhibit lots of cast shadows. This makes it very difficult to reconstruct the 3D topography with standard methods such as photogrammetry or standard clinometry. We apply a new method called ''Multiresolution PhotoClinometry by Deformation'' (MPCD, [2]) to retrieve the 3D topography of the area around Abydos. The method works in two main steps: (i) a DTM of this region is extracted from a low resolution MPCD global shape model of comet 67P/C-G, and (ii) the resulting triangular mesh is progressively deformed at increasing spatial sampling down to 0.25 m in order to match a set of 14 images of Abydos with projected pixel scales between 1 and 8 m. The method used to perform the image matching is a quasi-Newton non-linear optimization method called L-BFGS-b[3] especially suited to large-scale problems. Finally, we also checked the compatibility of the final MPCD digital terrain model with a set of five panoramic images obtained by the CIVA-P instrument aboard Philae[4]. [1] Lamy et al., 2016, submitted. [2] Capanna et al., Three dimensional reconstruction using multiresoluton photoclinometry by deformation, The visual Computer, v. 29(6-8) pp. 825-835, 2013. [3] Morales et al., Remark on "Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound constrained optimization", v.38(1) pp.1-4, ACM Trans. Math. Softw., 2011 [4] Bibring et al., 67P/Churyumov-Gerasimenko surface properties as

  4. Joint Cross-Range Scaling and 3D Geometry Reconstruction of ISAR Targets Based on Factorization Method.

    Science.gov (Un