  1. An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao [Imaging Center of Taian Central Hospital, Taian, Shandong (China); Gao, Fei; Li, Ning; Liu, Cheng [Shandong Univ., Shandong Medical Imaging Research Inst., CT Room, Shandong (China)], e-mail: liucheng491025@sina.com

    2013-10-15

    Background: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs. Purpose: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion. Material and Methods: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups. Results: Regional PBF (94.2{+-}36.5, 161.8 {+-}29.6, 185.7 {+-}38.1 and 125.5 {+-}46.1, 161.9 {+-}31.4, 169.3 {+-}51.7), PBV (6.7 {+-}2.8, 10.9 {+-}3.0, 12.9 {+-}4.5 and 9.9 {+-}4.6, 10.3 {+-}2.9, 11.9 {+-}4.5), and MTT (5.8 {+-}2.4, 4.5 {+-}1.3, 4.7 {+-}2.1 and 5.6 {+-}2.3, 4.3 {+-}1.5, 4.9 {+-}1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 {+-}30.6 vs. 94.9 {+-}15.9) and PBV (11.1 {+-}4.0 vs. 6.6 {+-}1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm. Conclusion: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

  2. Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT.

    Science.gov (United States)

    Cui, Y; Huang, M; Zheng, J; Li, J; Liu, H; Liang, C

    2016-01-01

    The aim of this study was to compare the coronary artery visibility and radiation dose in infants with CHD on cardiac 128-slice CT and on cardiac 64-slice CT. The images of 200 patients were analyzed in this study, 100 patients were selected randomly from a group of 789 infants (coronary artery segments was graded on a four-point scale. The coronary arteries were considered to be detected or visible when grade was 2 or higher. The visibility of the coronary artery segments and the radiation dose was compared between the two groups. Except for the rate of LM (96 vs. 99%), the detection rates of the total, LAD, LCX, RCA, and the proximal segment of the RCA in the 256-slice CT group were significantly higher than those in the 64-slice CT group (51.7, 53.33, 33.67, 53.33, and 99 vs. 34.8, 34.33, 18, 30.67, and 75%, respectively). The counts of visibility score (4/3/2/1) for the LM and the proximal segment of the RCA were 62/22/12/4 and 56/20/17/7, respectively, in the 128-slice CT group and 17/42/30/1 and 9/30/38/25, respectively, in the 64-slice CT group. There were significant differences, especially for score 4 and 3, between the two groups. The radiation dose in the 128-slice CT group was significantly decreased than those in the 64-slice CT group (CTDIvol 1.88 ± 0.51 vs. 5.61 ± 0.63 mGy; SSDE 4.48 ± 1.15 vs. 13.97 ± 1.52 mGy; effective radiation dose 1.36 ± 0.44 vs. 4.06 ± 0.7 mSv). With reduced radiation dose, the visibility of the coronary artery in infants with CHD via prospective ECG-triggered mode on a 128-slice CT is superior to that of the 64-slice CT using retrospective ECG-gated spiral mode.

  3. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin [University Hospital Tuebingen, Tuebingen (Germany)

    2010-10-15

    We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D Perfusion-CT. Phantom measurements were performed on a 128-slice single source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans

  4. Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Tsiflikas, Ilias; Kaempf, Michael; Claussen, Claus D; Heuschmid, Martin (Dept. of Diagnostic and Interventional Radiology, Univ. Hospital Tuebingen, Tuebingen (Germany)), email: dominik.ketelsen@med.uni-tuebingen.de; Buchgeister, Markus (Depts. of Radiotherapy and Radiooncology, Univ. Hospital Tuebingen, Tuebingen (Germany))

    2011-09-15

    Background: CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible. Purpose: To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). Material and Methods: An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated): 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm). Results: The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4-13.4 mSv and from 10.1-17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% +- 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% +- 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001). Conclusion: Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner

  5. Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT

    Science.gov (United States)

    Gu, Jin; Shi, He-Shui; Han, Ping; Yu, Jie; Ma, Gui-Na; Wu, Sheng

    2016-10-01

    This study sought to compare the image quality and radiation dose of coronary computed tomography angiography (CCTA) from prospectively triggered 128-slice CT (128-MSCT) versus dual-source 64-slice CT (DSCT). The study was approved by the Medical Ethics Committee at Tongji Medical College of Huazhong University of Science and Technology. Eighty consecutive patients with stable heart rates lower than 70 bpm were enrolled. Forty patients were scanned with 128-MSCT, and the other 40 patients were scanned with DSCT. Two radiologists independently assessed the image quality in segments (diameter >1 mm) according to a three-point scale (1: excellent; 2: moderate; 3: insufficient). The CCTA radiation dose was calculated. Eighty patients with 526 segments in the 128-MSCT group and 544 segments in the DSCT group were evaluated. The image quality 1, 2 and 3 scores were 91.6%, 6.9% and 1.5%, respectively, for the 128-MSCT group and 97.6%, 1.7% and 0.7%, respectively, for the DSCT group, and there was a statistically significant inter-group difference (P ≤ 0.001). The effective doses were 3.0 mSv in the 128-MSCT group and 4.5 mSv in the DSCT group (P ≤ 0.001). Compared with DSCT, CCTA with prospectively triggered 128-MSCT had adequate image quality and a 33.3% lower radiation dose.

  6. Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT: optimization of the CT protocol to reduce the radiation dose.

    Science.gov (United States)

    Kim, Sung Mok; Kim, Yoo Na; Choe, Yeon Hyeon

    2013-04-01

    The aim of this study was to compare the radiation dose and image quality of different adenosine-stress dynamic myocardial perfusion CT protocols using a 128-slice dual-source computed tomography (DSCT) scanner. We included 330 consecutive patients with suspected coronary artery disease. Protocols employed the following dynamic scan parameters: protocol I, a 30-s scan with a fixed tube current (FTC, n = 172); protocol II, a 30-s scan using an automatic tube current modulation (ATCM) technique (n = 108); protocol III, a 14-s scan using an ATCM (n = 50). To determine the scan interval for protocol III, we analyzed time-attenuation curves of 26 patients with myocardial perfusion who had been scanned using protocol I or II. The maximum attenuation difference between normal and abnormal myocardium occurred at 18.0 s to 30.3 s after initiation of contrast injection. Myocardial perfusion images of FTC and ATCM were of diagnostic image quality based on visual analysis. The mean radiation dose associated with protocols I, II, and III was 12.1 ± 1.6 mSv, 7.7 ± 2.5 mSv, and 3.8 ± 1.3 mSv, respectively (p < 0.01). Use of a dose-modulation technique and a 14-s scan duration for adenosine-stress CT enables significant dose reduction while maintaining diagnostic image quality.

  7. Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note

    Energy Technology Data Exchange (ETDEWEB)

    Feuchtner, Gudrun [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Innsbruck Medical University, Department of Radiology II, Innsbruck (Austria); Goetti, Robert; Marincek, Borut; Alkadhi, Hatem; Leschka, Sebastian [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Plass, Andre; Wieser, Monika [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Baumueller, Stephan; Stolzmann, Paul; Scheffel, Hans [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2010-09-15

    To describe prospective ECG-triggered dual-source CT dual-step pulsing (pECG{sub dual-step}) for evaluation of coronary arteries and cardiac function. Fifty-one consecutive patients pre- or post-cardiovascular surgery were examined with adaptive sequential tube current modulated (pECG{sub dual-step}) 128-slice dual-source CT without heart rate control (main padding window: 40% RR interval >65 bpm/70% RR interval <65 bpm). Image quality of coronary arteries was graded (4-point scale), and cardiac function was evaluated. Mean HR was 68 bpm. Thirty-seven patients were in stable sinus rhythm (SR); 14 had arrhythmia. Image quality of coronary arteries was diagnostic in 804/816 (98%) of segments. The number of non-diagnostic segments was higher in patients with arrhythmia as compared to those in SR (4% vs. 0.5%; p = 0.01), and there were fewer segments with excellent image quality (79% vs. 94%; p < 0.001) and more segments with impaired image quality (p < 0.001 and p = 0.002). Global and regional LV function could be evaluated in 41 (80%) and 47 (92%) patients, and valvular function in 48 (94%). In 11/14 of patients with arrhythmia, the second step switched to full mAs, increasing radiation exposure to 8.6 mAs (p < 0.001). The average radiation dose was 3.8 mSv (range, 1.7-7.9) in patients in SR. pECG{sub dual-step}128-slice DSCT is feasible for the evaluation of coronary arteries and cardiac function without heart rate control in patients in stable sinus rhythm at a low radiation dose. (orig.)

  8. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  9. Comparison of 128-Slice Low-Dose Prospective ECG-Gated CT Scanning and Trans-Thoracic Echocardiography for the Diagnosis of Complex Congenital Heart Disease

    Science.gov (United States)

    Bu, Guilin; Miao, Ying; Bin, Jingwen; Deng, Sheng; Liu, Taowen; Jiang, Hongchun; Chen, Weiping

    2016-01-01

    Objective To compare prospective ECG-gated multi-slice computed tomography (MSCT) and trans-thoracic echocardiography (TTE) in the diagnosis of complex congenital heart disease (CHD). Methods This was a prospective study of consecutive patients with complex CHD (age ECG-gated 128-slice spiral CT in the week before surgery. Effective radiation dose (ED) was calculated from volume CT dose index (CTDIvol) and dose length product (DLP). Image quality (5-point scale) was assessed independently by two radiologists. Using surgical findings as the reference, the diagnostic capabilities of MSCT and TTE were compared. Results Thirty-five patients (19 males) aged 1.59±1.58 years (range, 3 days to 74 months) were included. CTDIvol, DLP and ED were 0.90±0.24 mGy, 12.9±4.7 mGy∙cm and 0.64±0.21 mSv (range, 0.358–1.196 mSv), respectively. Image quality score was 4.3±0.5, and all images met the diagnostic requirements. The sensitivity, specificity, positive predictive value, and negative predictive value for diagnosing CHD were 97.2%, 99.8%, 99.0%, and 99.5%, respectively, for MSCT, and 90.6%, 99.8%, 99.0%, and 98.4%, respectively, for TTE. MSCT not only had a higher sensitivity than TTE overall (97.2% vs. 90.6%; PECG-gated CT scanning has important clinical value in the diagnosis of complex CHD in children, complementing and extending the findings of TTE. PMID:27788237

  10. Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation.

    Science.gov (United States)

    Park, Chan Kue; Choo, Ki Seok; Jeon, Ung Bae; Baik, Seung Kug; Kim, Yong Woo; Kim, Tae Un; Kim, Chang Won; Jeong, Yeon Ju; Jeong, Dong Wook; Lim, Soo Jin

    2013-06-01

    To compare vascular enhancement, image quality, and radiation dose of 128-slice dual-source CT venography (CTV) between an imaging setting of 120 kVp with low pitch, and a setting of 100 kVp combined with high pitch and automatic tube current modulation. A total of 100 patients with suspected deep vein thrombosis and varicose veins were divided into two groups: Group 1 [50 patients, 120 kVp, low pitch (0.6), and fixed 120 mA) and Group 2 (50 patients, 100 kVp, high pitch (3.0), and automatic tube current modulation]. Two radiologists, who were blinded to the image protocol, assessed vascular enhancement and image noise in the inferior vena cava (IVC), femoral vein, and popliteal vein. They also assigned an image quality score independently using a 5-point visual scale. Effective dose was estimated using the dose-length product (DLP). Group demographics, radiation dose, vascular enhancement, image noise, and image quality in the two groups were analyzed. Mean vascular enhancement of the IVC, femoral vein, and popliteal vein was significantly higher in group 2 than in group 1, and images in group 2 had significantly higher image noise. However, there were no significant differences in subjective image quality score of the IVC, femoral vein, and popliteal vein. The mean DLP in group 2 (402.10 ± 94.29 mGy cm) was significantly lower than that in group 1 (973.36 ± 63.20 mGy cm) (P enhancement with acceptable image quality and low radiation dose.

  11. Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chenying; Wang, Zufei; Ji, Jiansong; Wang, Hailin; Hu, Xianghua; Chen, Chunmiao [Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000 (China)

    2015-11-01

    To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.

  12. Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dong Wook (Dept. of Family Medicine, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do, (Korea, Republic of)); Choo, Ki Seok; Baik, Seung Kug; Kim, Yong Woo; Jeon, Ung Bae (Dept. of Radiology, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do, (Korea, Republic of)), email: kschoo0618@naver.com; Kim, Jeong Soo (Dept. of Cardiology, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do (Korea, Republic of)); Lim, Soo Jin (Dept. of Cardiology, Kim Hae Joongang Hospital, Gyeongsangnam-do (Korea, Republic of))

    2011-02-15

    Background: Little is known regarding image quality and the required radiation dose for step-and-shoot and retrospective coronary computed tomography angiography (CCTA) with tube current modulation (TCM) in 128-slice multidetector CT (MDCT) coronary angiography. Purpose: To compare image quality and radiation dose in patients who underwent 128-slice MDCT by the step-and- shoot method with those in patients who underwent 128-slice MDCT with retrospective CCTA with TCM. Material and Methods: CCTA obtained with 128-slice MDCT was retrospectively evaluated in 160 patients. Two independent reviewers separately scored the subjective image quality of the coronary artery segments (1, excellent; 4, poor) for step-and-shoot (68, mean heart rate [HR]: 59.3+-6.8) and retrospective CCTA with TCM (77, mean HR: 59.1+-9.8). Interobserver variability was calculated. Effective radiation doses of both scan techniques were calculated with dose-length product. Results: There was good agreement for quality scores of coronary artery segment images between the independent reviewers (k=0.72). The number of coronary artery segments that could not be evaluated was 2.85% (27 of 947) in the step-and-shoot and 1.87% (20 of 1071) in retrospective CCTA with TCM. Image quality scores were not significantly different (P>.05). Mean patient radiation dose was 63% lower for step-and-shoot (1.94+-0.70 mSv) than for retrospective CCTA with TCM (4.51+-1.18 mSv) (P<0.0001). For patients who underwent step-and-shoot or retrospective CCTA with TCM, an average HR of 63.5 beats per minute was identified as the threshold for the prediction of non-diagnostic image quality for both protocols. There were no significant differences in the image quality of both methods between obese (body mass index [BMI>=25) and non-obese patients (BMI<25), but radiation doses were higher in the obesity group than in the non-obesity group for both methods. Conclusion: Both step-and-shoot and retrospective CCTA with TCM using 128

  13. Contrastive Research on the Reliability of 128-Slice Spiral CT in the Measurement of Normal Occlusion Model%128层螺旋CT在正常模型测量中的可靠性研究

    Institute of Scientific and Technical Information of China (English)

    常捷; 李武; 滕永健; 赵晶帆

    2014-01-01

    Objective To verify the reliability, repeatability and accuracy of 128-slice spiral CT through comparing the measurement results of 128-slice spiral CT of 20 normal chin models with those of traditional manual measurement results.Methods The volume scanning with its data collection of normal chin models were conducted with 128-slice spiral CT. Then the images whose slice thicknesses were 0.6 mm were obtained through function reconstruction and then were transferred to various softwares including the 3D workstation, Dental and Inspace. The related indicators including the teeth width, dental arch length and dental arch width of maxillary and mandibular teeth were measured with axial images, MPR (Multiplanar Reconstruction), CPR (Curve Planar Reconstruction) and VR (Volume Reconstruction) while these indicators were also measured with vernier caliper manually. The measurement data collected from those two methods were analyzed and compared.Results The parallel validity of manual measurement was similar to CT measurement whose measurement error was-0.02~0.02 mm.Conclusion 128-slice spiral CT can meet the clinical orthodontic requirements.%目的:通过对20副正常模型的128层螺旋CT测量结果与传统手工测量结果进行比较,验证128层螺旋CT系统的可靠性、可重复性、精确性。方法应用128层螺旋CT机对正常模型进行容积扫描、数据采集,并进行函数重建得到0.6 mm层厚图像,传送至配套3D工作站、Dental(齿科软件)、Inspace(4D无间断实时互动三维成像技术)等软件,利用轴位图像、MPR(多平面重建)、CPR (曲面重建)、VR(容积重建)等方法测量正常模型的上、下颌牙的牙齿宽度,牙弓长度、宽度等相关指标;同时用游标卡尺手工测量上述指标,将两种测量方法所得数据进行比较。结果两种测量方法具有相似的平行效度。CT系统的测量误差为-0.02~0.02 mm,精确度较高。结论128层

  14. Research on 128-slice CT perfusion imaging of perigastric lymph node metastases of advanced gastric cancer%进展期胃癌胃周淋巴结的128层CT灌注成像研究

    Institute of Scientific and Technical Information of China (English)

    左晓娜; 曲红光; 王治民

    2016-01-01

    Objective:By studying the 128-slice spiral CT perfusion imaging of gastric cancer, this study aimed to investigate the per⁃fusion curves and perfusion imaging features of metastatic perigastric lymph nodes, reactive lymphoid hyperplasia (RLH) in the active stage and RLH in the quiescent stage;to find out the differences of the perfusion indexes including blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) of the different types of lymph nodes in advanced gastric cancer. Methods:From the 30 patients with gastric cancer diagnosed by surgery and pathological examination admitted in Gansu Provincial Hospital, 35 metastatic lymph nodes (Group A), 53 lymph nodes with reactive lymphoid hyperplasia (RLH) in the active stage (Group B) and 27 RLH lymph nodes in the quiescent stage were selected, and the time-density curves (TDC) of the three groups were compared, then the differences of the perfusion indexes were com⁃pared and analyzed by one-way analysis of variance (one-way ANOVA). Results:①The 128-slice spiral CT perfusion imaging of gastric can⁃cer could demonstrate the perfusion information inside the different types of perigastric lymph nodes, and could reflect the physiological func⁃tions of the lymph nodes precisely;②The results of BF, BV, MTT and PS of metastatic perigastric lymph nodes, RLH lymph nodes in the reac⁃tive stage and RLH lymph nodes in the quiescent stage were statistically different. Conclusion: The 128-slice spiral CT perfusion imaging of gastric cancer can reflect the changes of the perfusion indexes of perigastric lymph nodes visually, and can provide the objective and quantita⁃tive information of thehemodynamic changes of the lymph nodes. Combined with enhanced imaging and various post-processing technologies, the 128-slice spiral CT perfusion imaging can provide more valuable information for thelocating and the qualitative diagnosis of the perigastric lymph nodes and the preoperative staging

  15. Acute aortic syndromes: Role of multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca; Renda, Pietro [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy); Fiore, Davide [Department of Radiology, University of Padova, Padova (Italy); Scaglione, Mariano [Emergency and Trauma CT Section, Department of Radiology, Cardarelli Hospital, Naples (Italy); Piccoli, GianPiero [Cardiosurgery Division, Ospedali Riuniti ' Torrette-Lancisi-Salesi' , Ancona (Italy); Giovagnoni, Andrea [Department of Radiology, University ' Politecnica delle Marche' , Ancona (Italy)], E-mail: a.giovagnoni@univpm.it

    2008-03-15

    Acute thoracic aortic syndromes encompass a spectrum of emergencies including aortic dissection, intramural haematoma, penetrating atherosclerotic ulcer and aneurysm rupture. All these life-threatening conditions require prompt diagnosis and appropriate management. To date multi-detector row Computed Tomography represents a valuable diagnostic tool especially in the emergency setting. This paper focus on the use of multi-detector row Computed Tomography in the evaluation of acute thoracic aortic syndromes and illustrates the key imaging findings related to each disease.

  16. Initial experience with prospectively triggered, sequential CT coronary angiography on a 128-slice scanner; Erste Erfahrungen mit der sequenziellen, prospektiv getriggerten CT-Koronarangiografie an einem 128-Schicht-Computertomografen

    Energy Technology Data Exchange (ETDEWEB)

    Anders, K.; Baum, U.; Kuefner, M.A.; Kuettner, A.; Uder, M. [Universitaetsklinikum Erlangen (Germany). Radiologisches Inst.; Gauss, S.; Achenbach, S.; Daniel, W.G.; Ropers, D. [Universitaetsklinikum Erlangen (Germany). Medizinische Klinik 2

    2009-04-15

    Purpose: Spiral CT angiography (CTA) of the coronaries using low-pitch scanning and ECG-gated image reconstruction is a robust method for detecting or excluding relevant coronary plaque. However, the resulting dose exposure is considerable. The aim of the present study was to evaluate image quality and artifacts as well as to record dose values for sequential coronary CTA using a 128-slice scanner with a temporal resolution of 150 ms. Materials und Methods: 20 patients with a regular heart rate and without contraindications for oral/I.V. beta blockers, who were referred for CTA of the coronaries for exclusion or detection of relevant plaques, were examined by sequential CTA with the following parameters: 120 kV, 200 ref mAs, collimation 2 x 64 x 0.6, table feed of 34.5 mm at a detector width of 38.4 mm. A total acquisition time of 380 ms per table position allowed for mild shifting of the reconstruction window within the cardiac cycle of {+-} 5 %. 50 ml of contrast agent were injected at 5 ml/s followed by a 50 ml split bolus (20 % contrast). The individual start delay was determined by a test bolus scan (10 ml contrast + 50 ml saline flush at 5 ml/s). The image quality for each segment, coronary artery, and patient was determined on a 4-point scale. Dose values were estimated based on the individual dose length product as provided by the scanner's patient protocol. Artifacts were evaluated to determine the cause (calcium vs. motion). Results: All patients received beta blocker pretreatment. The mean heart rate was 62 {+-} 5 beats/min. 5 % (13/286) of all segments in 5/20 patients were rated as non-diagnostic. The mean dose length product was 213 mGy x cm, and the mean effective dose was 3.6 mSv. Calcifications were the major cause of non-diagnostic images. However breathing or other motion artifacts occurred as well. (orig.)

  17. Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jean-Francois; Rohnean, Adela; Elfassy, Eric; Sigal-Cinqualbre, Anne [Radiology-Centre Chirurgical Marie Lannelongue, Plessis-Robinson (France)

    2011-02-15

    For coronary artery visualization, retrospective ECG-gated acquisition by dual-source computed tomography (DSCT) was superior to spiral non-ECG-gated acquisition in a paediatric population of congenital heart disease (CHD) patients. However, retrospective cardiac CT is associated with substantial radiation doses to the patient. Recently, DSCT with end-systolic reconstruction was found to be robust for imaging the coronary arteries in patients with high heart rates. To evaluate step-and-shoot DSCT with end-systolic reconstruction for evaluating the heart, coronary arteries and other thoracic structures in young children with CHD. All neonates and children younger than 6 years of age who were referred to our institution for CHD evaluation between September and October 2009 were included in the study. ECG-gated DSCT was performed in sequential prospective mode centred on the systolic phase identified by ECG analysis. To assess the radiation dose, we recorded the dose-length product (DLP) in mGy.cm and the effective dose in mSv estimated from the DLP. Overall image quality was evaluated using a 5-grade scoring system and was assessed by looking at cardiac and vascular structures. The image quality for the proximal and middle segments of the right and left coronary arteries was also evaluated using a 5-grade scale. Images of diagnostic quality (grade {>=} 3) were obtained in all 30 children with a mean image quality grade of 4.7 {+-} 0.6 (range, 3-5). Mean DLP was 5.7 {+-} 4.8 mGy*cm (range, 1-22 mGy cm) and mean effective radiation dose was 0.26 {+-} 0.16 mSv (range, 0.05-0.8 mSv). Prospective ECG-gated thoracic DSCT at end-systole usually provides adequate thoracic and coronary artery image quality in neonates, infants and young children with CHD, independent of heart rate. This new method is associated with lower radiation doses compared to previous literature (mean effective dose, 0.26 mSv). (orig.)

  18. 128层螺旋CT扫描容积重建诊断肋骨骨折的临床价值%Value of volume vendering after 128-slice spiral CT in the diagnosis of rib fracture

    Institute of Scientific and Technical Information of China (English)

    董延鸣; 徐伟; 石渠

    2013-01-01

    目的 探讨128 层螺旋CT扫描容积重建诊断肋骨骨折的临床价值.方法 回顾性分析100 例378根肋骨及20 根肋软骨骨折病例,采用薄层(0.625 mm)重组、容积再现(VR)重建技术进行肋骨及肋软骨重建,并在工作站上进行多角度、全方位动态观察.结果 100 例肋骨发现320 根378 处骨折,其中多发骨折85 例305 根,单发性骨折15 例;单侧肋骨骨折78 例257 根,双侧骨折22 例共121 根;肋软骨骨折20 例,不全性骨折45 根.合并肺挫伤35 例,气胸26 例,血气胸18 例,脾挫裂伤8 例、肝挫裂伤3 例.结论 胸部外伤患者行128 层螺旋CT常规扫描后,薄层重组结合容积重建对肋骨骨折及其并发症的诊断有非常重要的价值.%Objective To investigate the value of volume vendering after 128-slice spiral CT in the diagnosis of rib fracture. Methods The clinical data of 100 patients (378 rib fractures and 20 costalcartilages fractures) were retrospectively analyzed. The thin-slice reconstruction (0.652 mm), volume vendering (VR) were applied for the reconstruction of rib and costalcartilages. Multi-angel, comprehensive, dynamic observation in the workstation was performed. Results A total of 378 rib fractures in 320 ribs were found, including multiple rib fracture in 305 ribs in 85 patients, comminuted rib fracture in 15 ribs in 15 patients, of which 257 fractured ribs were on the same side (in 78 patients) and 121 were on two sides (in 22 patients). A total of 20 patients with costalcartilages fractures were found, with 45 ribs of incomplete rib fracture. Thirty-five patients were found with lung contusion, 26 with pneumothorax, 18 with hemopnemothorax, 8 with dampened spleen and 3 with dampened liver. Conclusion Thin-slice reconstruction and volume vendering after 128-slice spiral CT scan has very important value in the diagnosis of ribs fracture and complications in patients with chest trauma.

  19. Evaluation of 128-slice spiral CT whole brain perfusion imaging in grading infiltrating astrocytomas%128层螺旋CT全脑灌注对浸润性星形细胞瘤的分级评估

    Institute of Scientific and Technical Information of China (English)

    曾文兵; 王毅; 汪明全; 吴炅; 刘兴华; 罗江平; 温云

    2011-01-01

    目的:评价128层螺旋CT全脑灌注(CTP)对浸润性星形细胞瘤分级定性诊断的价值.方法:选择我院90例脑肿瘤患者进行CTP检查,经手术和病理学证实为浸润性星形细胞瘤(Ⅱ~Ⅳ级)者46例纳入本研究对象.CTP采用SOMATOM Definition AS型128层螺旋CT机进行灌注扫描,应用后处理工作站对原始数据进行后处理.获得时间-密度曲线(TDC).测定肿瘤区和对侧正常组织的脑血流量(CBF)、脑血容量(CBV)、毛细血管表面通透性(PS)及对比剂达峰值时间(TTP),并对灌注参数进行统计学分析.结果:在所有病例中,全脑灌注图像平均视觉评价分数明显高于传统灌注图(P<0 01).且对病变定位更为精确.星形细胞肿瘤高级别组的CBF、CBV和PS值均显著高于低级别组(P<0.01).而TTP值的差异无统计学意义(P>0.05).ROC曲线分析表明,CBF、CBV和PS值对鉴别高、低级别星形细胞肿瘤的ROC曲线下面积分别为0.925、0.897和0.954.采用CBF≥72.052ml/min/100g,CBV≥4.293ml/100g和PS≥6.337ml/min/100g作为分界点对鉴别高低级别星形细胞肿瘤的敏感性均为87.2%,特异性分别是83.5%、83.5%和93.0%.结论:128层螺旋CT全脑灌注有利于脑肿瘤的术前整体评估和精确定位;CTP参数CBF、CBV及PS值及TDC曲线对鉴别高、低级别星形细胞肿瘤具有较高的敏感性和特异性.%Objective:To evaluate the value of 128-slicc spiral CT whole brain perfusion (CTP) imaging in grading infil-traiing astrocytomas. Methods: Ninety patients with brain rumors underwent CTP examination and forty-six of them with astrocytic tumors (Ⅱ -Ⅳ) confirmed by operation and pathology were selected as the object of this study. 128-slice helical CT whole brain perfusion imaging was performed in the 46 patients, and the data were analyzed by the software. Cerebral blood flow (CBF). Cerebral blood volume (CBV). Time to peak (TTP) and permeability surface (PS> on the maximum perfusion area

  20. Multi-detector CT in the paediatric urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Damasio, M.B., E-mail: mariabdamasio@ospedale-gaslini.ge.it [Paediatric Radiology, Giannina Gaslini Institute, Genoa (Italy); Darge, K. [Department of Radiology, Children' s Hospital of Philadelphia, Philadelphia (United States); Riccabona, M. [Department of Radiology, Division of Paediatric Radiology, University Hospital Graz (Austria)

    2013-07-15

    The use of paediatric multi-slice CT (MSCT) is rapidly increasing worldwide. As technology advances its application in paediatric care is constantly expanding with an increasing need for radiation dose control and appropriate utilization. Recommendations on how and when to use CT for assessment of the paediatric urinary tract appear to be an important issue. Therefore the European Society of Paediatric Radiology (ESPR) uroradiology task force and European Society of Urogenital Radiology (ESUR) paediatric working groups created a proposal for performing renal CT in children that has recently been published. The objective of this paper is to discuss paediatric urinary tract CT (uro-CT) in more detail and depth. The specific aim is not only to offer general recommendations on clinical indications and optimization processes of paediatric CT examination, but also to address various childhood characteristics and phenomena that facilitate understanding the different approach and use of uro-CT in children compared to adults. According to ALARA principles, paediatric uro-CT should only be considered for selected indications provided high-level comprehensive US is not conclusive and alternative non-ionizing techniques such as MR are not available or appropriate. Optimization of paediatric uro-CT protocols (considering lower age-adapted kV and mAs) is mandatory, and the number of phases and acquisition series should be kept as few as possible.

  1. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nie, Pei; Wang, Ximing; Cheng, Zhaoping; Ji, Xiaopeng; Duan, Yanhua [Shandong University, Shandong Provincial Key Laboratory of Diagnosis and Treatment of Cardio-cerebral Vascular Diseases, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Chen, Jiuhong [CT Research Collaboration, Siemens Ltd. China, Beijing (China)

    2012-10-15

    To compare accuracy, image quality and radiation dose between high-pitch spiral and sequential modes on 128-slice dual-source computed tomographic (DSCT) angiography in children with congenital heart disease (CHD). Forty patients suspected with CHD underwent 128-slice DSCT angiography with high-pitch mode and sequential mode respectively. All the anomalies were confirmed by the surgical and/or the conventional cardiac angiography (CCA) findings. The diagnostic accuracy, the subjective and objective image quality and effective radiation doses were compared. There was no significant difference in diagnostic accuracy ({chi}{sup 2} = 0.963, P > 0.05), the objective parameters for image quality (P > 0.05) and the image quality of great vessels (u = 167.500, P > 0.05) between the two groups. The image quality of intracardiac structures and coronary arteries was significantly better in the sequential mode group than that in the high-pitch group (u = 112.500 and 100.000, P < 0.05). The mean effective dose in high-pitch group (0.17 {+-} 0.05 mSv) was significantly lower (t = 5.287, P < 0.05) than that in the sequential mode group (0.29 {+-} 0.09 mSv). Both the high-pitch and the sequential modes for 128-slice DSCT angiography provide high accuracy for the assessment of CHD in children, while the high-pitch mode, even with some image quality decrease, further significantly lowers the radiation dose. (orig.)

  2. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  3. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT.

    Science.gov (United States)

    Scheffel, Hans; Pfammatter, Thomas; Wildi, Stefan; Bauerfeind, Peter; Marincek, Borut; Alkadhi, Hatem

    2007-06-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding.

  4. 128层螺旋CT前门控技术在小儿复杂性先天性心脏病中的应用%Application of prospectively electrocardiograph-gated 128-slice spiral CT angiography in children with complex congenital heart disease

    Institute of Scientific and Technical Information of China (English)

    张晓凡; 曾立红; 王志伟; 王芳

    2013-01-01

    Objective To evaluate the prospective electrocardiograph (ECG)-gated 128-slice spiral CT angiography in the diagnosis of complex congenital heart disease and airway abnormality in children.Methods Eighty children with congenital heart disease received prospective (n =40) or retrospective ECG-gated 128-slice spiral CT angiography (n =40).All of the patients underwent ultrasound cardiogram (UCG) within one week before CTA exmination.The image quality and the effective radiation dose were statistically analyzed using independent samples t test and x2 test.The surgical results were taken as the diagnostic standards,and the preoperative prospective and retrospective CT angiography data were compared with UCG results using x2 test.Results The effective dose of prospective ECG-gated CT angiography[(1.00 ± 0.26)mSv] was reduced by 86% as compared with the retrospective ECG-gated CT angiography[(7.37 ± 0.52) mSv] (t =69.296,P < 0.01).Image quality was graded 0 in none patients,graded 1 in 2 patients who underwent prospective ECG-gated CT angiography,graded 2 in 8 and 1 patient who received prospective and retrospective ECG-gated CT angiography respectively,and graded 3 in 30 and 39 patients who underwent prospective and retrospective ECG-gated CT angiography,respectively.There was no significant difference in image quality between prospective and retrospective ECG-gated CT angiography (x2 =0.044,P > 0.05).The definitive diagnosis of extracardiac vascular anomalies was made in 98.3%(59/60) of patients by using prospective and retrospective ECG-gated CT angiography,which were significantly superior to UCG results[(76.7% (46/60),76.7% (45/59),respectively] (x2 =13.144,12.644,P < 0.01),and there was no significant difference in the definitive diagnosis between prospective and retrospective ECG-gated CT angiography (x2 =0.001,P > 0.05).The definitive diagnosis of the cardiac/large-vessel malformations was made in 100% of the patients by both prospective and

  5. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.

    Science.gov (United States)

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-12-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.

  6. Determination of the weighted CT dose index in modern multi-detector CT scanners.

    Science.gov (United States)

    Perisinakis, K; Damilakis, J; Tzedakis, A; Papadakis, A; Theocharopoulos, N; Gourtsoyiannis, N

    2007-11-07

    The aim of the present study was to (a) evaluate the underestimation in the value of the free-in-air (CTDI(air)) and the weighted CT dose index (CTDI(w)) determined with the standard 100 mm pencil chamber, i.e. the CTDI(100) concept, for the whole range of nominal radiation beam collimations selectable in a modern multi-slice CT scanner, (b) estimate the optimum length of the pencil-chamber and phantoms for accurate CTDI(w) measurements and (c) provide CTDI(w) values normalized to free-in-air CTDI for different tube-voltage, nominal radiation beam collimations and beam filtration values. The underestimation in the determination of CTDI(air) and CTDI(w) using the CTDI(100) concept was determined from measurements obtained with standard polymethyl-methacrylate (PMMA) phantoms and arrays of thermoluminescence dosimeters. The Monte Carlo N-Particle transport code was used to simulate standard CTDI measurements on a 16-slice CT scanner. The optimum pencil-chamber length for accurate determination of CTDI(w) was estimated as the minimum chamber length for which a further increase in length does not alter the value of the CTDI. CTDI(w)/CTDI(air) ratios were determined using Monte Carlo simulation and the optimum detector length for all selectable tube-voltage values and for three different values of beam filtration. To verify the Monte Carlo results, measured values of CTDI(w)/CTDI(air) ratios using the standard 100 mm pencil ionization chamber were compared with corresponding values calculated with Monte Carlo experiments. The underestimation in the determination of CTDI(air) using the 100 mm pencil chamber was less than 1% for all beam collimations. The underestimation in CTDI(w) was 15% and 27% for head and body phantoms, respectively. The optimum detector length for accurate CTDI(w) measurements was found to be 50 cm for the beam collimations commonly employed in modern multi-detector (MD) CT scanners. The ratio of CTDI(w)/CTDI(air) determined using the optimum

  7. Pitfalls in detection of acute gastrointestinal bleeding with multi-detector row helical CT.

    Science.gov (United States)

    Stuber, T; Hoffmann, M H K; Stuber, G; Klass, O; Feuerlein, S; Aschoff, A J

    2009-07-01

    Contrast-enhanced multi-detector row helical CT angiography is establishing itself as an accurate, rapid, and non-invasive diagnostic modality in patients with acute gastrointestinal bleeding. On arterial phase MDCT images ongoing hemorrhage can be revealed as an area of active extravasation of contrast material within the bowel lumen. This pictorial essay gives a short overview of current diagnostic modalities in assessing acute GI tract bleeding, typical MDCT findings, and depicts potential pitfalls in the detection of acute GI bleeding with MDCT.

  8. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  9. CT angiography of pulmonary embolism using a 64 slice multi-detector scanner

    Institute of Scientific and Technical Information of China (English)

    QIN Nai-shan; JIANG Xue-xiang; QIU Jian-xing; ZHU Ying; WANG Ji-chen

    2009-01-01

    Background Multi-detector computed tomography (MDCT) has already been the first line investigation method for diagnosis of pulmonary embolism (PE). Reducing the amount of contrast medium used during CT scanning could decrease the incidental rate of adverse reactions. Our study amied to evaluate the image quality of pulmonary arteries using 64 slice multi-detector CT with small volumes of contrast media injection.Methods Forty nonconsecutive patients without PE or other lung diseases were randomly assigned to two groups.Group A underwent CT scanning with 16×1.25 mm collimation and a 70 ml contrast injection, while group B had CT with 64×0.625 mm collimation and 20 ml of contrast injection. Two readers independently depicted the segmental and subsegmental pulmonary arteries. Reasons we could not analyze the pulmonary artery or that led to misdiagnosis of pulmonary embolism were evaluated, including the degree of contrast enhancement of the main pulmonary artery, and factors that caused misdiagnosis of PE (flow-related artifacts, partial volume artifact, beam-hardening artifacts and enhancement of pulmonary vein). The independent samples t-test, Mann-Whitney U test and Pearson chi-square test were applied.Results There were no significant differences in image quality of segmental and subsegmental arteries between the two groups. No significant difference was found for factors that made pulmonary arteries non-analyzable or in the misdiagnosis of PE, except the degree of contrast enhancement.Conclusion 64×0.625 mm collimation with 20 ml contrast injection could depict the pulmonary arteries well.

  10. The clinical value on the pre-operation of styloid process syndrome diagnosed by 128-slice spiral CT%128层螺旋 CT 在茎突综合征术前诊断中的临床价值

    Institute of Scientific and Technical Information of China (English)

    左开荣

    2014-01-01

    目的:探讨128层螺旋 CT 在茎突综合征术前诊断中的临床价值。方法回顾性分析50例(100侧)正常成人(对照组)和48例(96侧)经手术证实的茎突综合征患者(SPS 组)的临床及影像资料,并对两组患者的茎突长度和倾角分布的差异进行统计分析。结果对照组中,茎突过长(长度>30mm)8侧(8%),前倾角过大(角度>25°)2侧(2%),内倾角过大(角度>25°)4侧(4%);而 SPS 组中,茎突过长56侧(58.3%),前倾角过大14侧(14.6%),内倾角过大18侧(18.8%),茎突过长伴倾角异常10侧(10.4%)。经统计学分析,SPS 组的茎突过长及倾角过大的检出率明显高于对照组,差异具有统计学意义(P<0.05)。结论茎突综合征在影像学上主要表现为茎突过长和(或)倾角过大,128层螺旋 CT 三维重建技术能为临床提供可靠的影像学依据,在茎突综合征术前诊断中具有重要临床价值。%Objective To explore the clinical value on the pre-operation of styloid process syndrome diagnosed by 128-slice spiral CT. Methods Retrospectively analyzed 50 cases (100sides) of normal adult (control group) and 48 cases(96 sides) of styloid process syndrome diagnosed by operation (SPS group). The differences between two groups in the length and angle distribution of the styloid process were analyzed statistically. Results Eight sides of control group (8%) had the elon-gated styloid process (the lenght was more than 30mm),two sides (2%) had the larger anteversion angle (the angle was more than 25°),four sides (4%) had the larger inclination angle (more than 25°);48 cases of SPS group, 56 sides (58.3%) had the elongated styloid process,14 sides (14.6%) had the larger anteversion angle, 18 sides (18.8%) had the larger inclination an-gle,10 sides (10.4%) had the elongated styloid process coupled with abnormal inclination. Analyzed by statistics, the detection

  11. Study on the value of 128 slice spiral CT angiography in the evaluation of the symptomatic supra-aortic arteries stenosis dis- ease%128层螺旋 CT 血管造影评价症状性主动脉弓以上动脉狭窄的价值研究

    Institute of Scientific and Technical Information of China (English)

    张磊; 陈静静

    2016-01-01

    目的:以数字减影血管造影(DSA)结果为对照标准,评价128层螺旋 CT 血管造影(CTA)判断主动脉弓以上动脉狭窄程度的准确性。方法收集2014年1月至2015年2月临床怀疑主动脉弓以上动脉狭窄性病变患者21例,均行主动脉弓以上 CTA 检查,并在2周内行 DSA 检查,将 CTA 与 DSA 检出结果进行对比,观察 CTA 的敏感度和特异度,评价128层螺旋 CT 血管造影诊断主动脉弓以上动脉狭窄的准确性。结果21例362段血管 CTA 和 DSA 诊断符合数为353段(97.5%),128层螺旋 CT 血管造影诊断主动脉弓以上动脉狭窄的总的敏感度为100%,特异度为99.66%,阳性预测值为98.57%,阴性预测值为100%。结论128层 CTA 作为一种无创或微创性检查,有较高的敏感度和特异度,可用于主动脉弓以上动脉狭窄的术前诊断、术后效果评价。%Objective To evaluate the accuracy of 128 slice spiral CT angiography in the evaluation of the supra-aortic arter-ies stenosis disease in comparison with DSA results. Methods From January 2014 to February 2015,21 patients with suspected supra-aortic arteries stenosis disease were selected. The patients underwent cerebral and carotid CTA examination and DSA exam-ination in two weeks. The sensitivity and specifility of CTA were analyzed compared with DSA,the accuracy of 128-slice CTA in diagnosis of cerebral and carotid arterious stenosis was evaluated. Results The CTA readings correlated with DSA findings in 353 vessels(97. 5% ),the sensitivity of 128-sile CTA in diagnosis supra-aortic arteries was 100% ,the specialty was 99. 66% , the positive predictive value was 98. 57% ,and the negative predictive value was 100% . Conclusion 128-silce spiral CTA is a noninvasive or minimally invasive inspection,which has high sensitivity and specificity. CTA can be used for preoperative diagni-sis,post-operative evaluation and epidemiological investigation of supra-aortic arteries

  12. Bronchial anatomy of left lung: a study of multi-detector row CT.

    Science.gov (United States)

    Zhao, Xinya; Ju, Yuanrong; Liu, Cheng; Li, Jianfeng; Huang, Min; Sun, Jian; Wang, Tao

    2009-02-01

    Familiarity with prevailing pattern and variations in the bronchial tree is not only essential for the anatomist to explain bronchial variation in bronchial specimens, but also useful for guiding bronchoscopy and instructing pulmonary segmental resection. The purpose of this study was designed to demonstrate various branching patterns of left lung with 3D images, with special attention given to identify the major types at transverse thin-section CT. Two hundred and sixteen patients with routine thorax scans were enrolled. The images of bronchial tree, virtual bronchoscopy were reconstructed using post-processing technique of multi-detector row CT. We attempted to classify the segmental bronchi by interpreting the post-processing images, and identified them in transverse thin-section CT. Our results showed that the segmental bronchial ramifications of the left superior lobe were classified into three types mainly, i.e., common stem of apical and posterior segmental bronchi (64%, 138/216); trifurcation (23%, 50/216); common stem of apical and anterior segmental bronchi (10%, 22/216), and they could be identified at two typical sections of transverse thin-section CT. There were two major types in left basal segmental bronchi, i.e., bifurcation (75%, 163/216), trifurcation (18%, 39/216), and they could also be identified at two typical sections of transverse thin-section CT. In conclusion, our study have offered simplified branching patterns of bronchi and demonstrated various unusual bronchial branching patterns perfectly with 3D images, and have also revealed how to identify the main branching patterns in transverse thin-section CT.

  13. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma

    Institute of Scientific and Technical Information of China (English)

    Luigi; Camera; Rosa; Severino; Antongiulio; Faggiano; Stefania; Masone; Gelsomina; Mansueto; Simone; Maurea; Rosa; Fonti; Marco; Salvatore

    2014-01-01

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography(CT) or magnetic resonance(MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved bysomatostatin-receptor scintigraphy(SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR(Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT(Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure(3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  14. Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma.

    Science.gov (United States)

    Camera, Luigi; Severino, Rosa; Faggiano, Antongiulio; Masone, Stefania; Mansueto, Gelsomina; Maurea, Simone; Fonti, Rosa; Salvatore, Marco

    2014-10-28

    Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography (CT) or magnetic resonance (MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved by somatostatin-receptor scintigraphy (SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR (Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT (Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure (3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis.

  15. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  16. Correlation between Acute Coronary Syndrome Classification and Multi-detector CT Characterization of Plaque

    Institute of Scientific and Technical Information of China (English)

    Zhi-guo Wang; Lu-yue Gai; Jing-jing Gai; Ping Li; Xia Yang; Qin-hua Jin; Yun-dai Chen; Zhi-jun Sun; Zhi-wei Guan

    2011-01-01

    Objective To determine if multi-detector CT (MDCT) characterization of plaque is correlated with the classification of acute coronary syndrome (ACS). Methods Altogether 1900 patients were examined by MDCT from December 2007 to May 2009,of whom 95 patients fulfilled the criteria of ACS. Those patients were divided into the discrete plaque group (n=61) and diffuse plaque group (n=34) based on the findings in MDCT. The clinical diagnosis of ACS and CT results were analyzed, including segment stenosis score, segment involvement score, 3-vessel plaque score, left main score, calcification score, and remodeling index. The incidences of major adverse cardiac events in follow-up period were also recorded.Results The patients of the diffuse plaque group were older than those of the discrete plaque group (P<0.0001). The diffuse plaque group presented more cases of hypertension, peripheral artery disease, diabetes, and heart failure than discrete plaque group (all P<0.05). All the 5 patients with ST-segment elevation myocardial infarction were found in discrete plaque group. The segment stenosis score of the discrete plaque group was lower than that of the diffuse plaque group (5.15+3.55 vs. 14.91+5.37, P<0.001). The other four scores demonstrated significant inter-group difference as well (all P<0.05). The remodeling index of the discrete plaque group was higher (1.12+0.16 vs. 0.97+0.20, P<0.05). Follow-up data showed that major adverse cardiac events occurred more frequently in diffuse plaque group than in discrete group (29.41% vs.11.48%, P=0.0288).Conclusions Characteristics of discrete and diffuse plaques may be significandy different among different classes of ACS. The diffuse plaque may present higher risk, correlated to higher mortality. The diagnosis of discrete and diffuse plaques by MDCT would provide a new insight into the prognosis and treatment of ACS.

  17. Multi-detector CT angiography for lower gastrointestinal bleeding: Can it select patients for endovascular intervention?

    Science.gov (United States)

    Foley, P T; Ganeshan, A; Anthony, S; Uberoi, R

    2010-02-01

    This is a retrospective review of the results at our institution of using multi-detector CT angiography (CTA) to localise lower gastrointestinal (GI) bleeding. We hypothesised that in our patient population: (i) CTA was unlikely to demonstrate bleeding in patients who were haemodynamically stable; (ii) in haemodynamically unstable patients in whom CTA was undertaken, the results could be used to select patients who would benefit from catheter angiography; and (iii) in haemodynamically unstable patients in whom CTA was undertaken, a subgroup of patients could be identified who would benefit from primary surgical treatment, avoiding invasive angiography completely. A retrospective review was conducted of the clinical records of all patients undergoing CTA for lower GI haemorrhage at our institution between 1 January 2005 and 30 June 2007. Out of the 20 patients examined, 10 had positive CTAs demonstrating the bleeding site. Nine were haemodynamically unstable at the time of the study. Four patients with positive CT angiograms were able to be treated directly with surgery and avoided invasive angiography. Ten patients had negative CTAs. Four of these were haemodynamically unstable, six haemodynamically stable. Only one required intervention to secure haemostasis, the rest stopped spontaneously. No haemodynamically stable patient who had a negative CTA required intervention. CTA is a useful non-invasive technique for localising the site of lower GI bleeding. In our patient population, in the absence of haemodynamic instability, the diagnostic yield of CTA was low and bleeding was likely to stop spontaneously. In haemodynamically unstable patients, a positive CTA allowed patients to be triaged to surgery or angiography, whereas there was a strong association between a negative CTA and spontaneous cessation of bleeding.

  18. Multi-Detector row CT urography on a 16-row CT scanner in the evaluation of urothelial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, A.C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); University of Ioannina, Medical School, Ioannina (Greece); Efremidis, S.C.; Tsampoulas, C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); Kalef-Ezra, J. [University Hospital of Ioannina, Department of Medical Physics, Ioannina (Greece); Giannakis, D.; Sofikitis, N. [University Hospital of Ioannina, Department of Urology, Ioannina (Greece); Alamanos, Y. [University Hospital of Ioannina, Department of Hygiene and Public Health, Ioannina (Greece)

    2007-04-15

    The purpose of this study was to assess the role of multi-detector row CT urography (MDCTU), on a 16-row CT scanner in the evaluation of patients with painless hematuria, with emphasis placed in the detection of urothelial tumors. We retrospectively reviewed the MDCT urographies of 75 patients, referred for painless hematuria. The CT protocol included unenhanced images, obtained with a detector configuration of 16 x 1.5 mm and pitch of 1.2, nephrographic and excretory-phase images, obtained with a detector collimation of 16 x 0.75 mm and pitch of 1.2. Axial and coronal reformatted images were evaluated. Three-dimensional reformation of the excretory-phase images was performed using the volume-rendering technique. The standard of reference included clinical and imaging follow-up, cystoscopic, surgical and histologic findings. In 55 (73%) of 75 patients, the cause of hematuria was identified on MDCTU; the most common cause was urothelial cancer, including seven tumors with a diameter equal or smaller than 0.5 cm in diameter. Sixteen-row MDCTU provided satisfactory results in the investigation of patients with painless hematuria. The main advantage of the technique is its ability to detect uroepithelial malignancies. (orig.)

  19. Multi-detector CT enterography with iso-osmotic mannitol as oral contrast for detecting small bowel disease

    Institute of Scientific and Technical Information of China (English)

    Lian-He Zhang; Shi-Zheng Zhang; Hong-Jie Hu; Min Gao; Ming Zhang; Qian Cao; Qiao-wei Zhang

    2005-01-01

    AIM: To assess the feasibility and usefulness of multi-detector CT enterography with orally administered iso-osmotic mannitol as negative contrast in demonstrating small bowel disease.METHODS: Thirteen volunteers and 38 patients with various kinds of small bowel disease were examined. We administered about 1 500 mL iso-osmotic mannitol as negative contrast agent and then proceeded with helical CT scanning on a Siemens Sensation 16 scanner. All volunteers and patients were interviewed about their tolerance of the procedure. Two radiologists postprocessed imaging data with MPR, thin MIP, VRT and INSPACE when necessary and then interpreted the scans,and adequacy of luminal distention was evaluated on a four-point scale. Demonstration of features of various kinds of small bowel disease was analyzed.RESULTS: The taste of iso-osmotic mannitol is good (slightly sweet) and acceptable by all. Small bowel distention was excellent and moderate in most volunteers and patients. CT features of many kinds of diseases such as tumors, Crohn's disease,and small bowel obstruction,etc. were clearly displayed.CONCLUSION: Multi-detector CT enterography with iso-osmotic mannitol as negative contrast to distend the small bowel is a simple, rapid, noninvasive and effective method of evaluating small bowel disease.

  20. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  1. Multi-detector CT: review of its use in acute GI haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, S.; Milburn, S. [Department of Radiology, John Radcliffe Hospital, Oxford (United Kingdom); Uberoi, R. [Department of Radiology, John Radcliffe Hospital, Oxford (United Kingdom)], E-mail: raman.uberoi@orh.nhs.uk

    2007-10-15

    The advent of multi-section computed tomography (CT) technology allows the non-invasive assessment of the arterial tree. Using current software, it is now possible to produce high-quality, angiographic-like images that can be used to plan and guide therapeutic procedures. One such clinical situation is the assessment of patients with acute gastrointestinal (GI) haemorrhage. Multi-section CT has a number of advantages over conventional angiography in this situation. The simplicity and non-invasive nature of the technique compared with conventional angiography make CT angiography possible in situations where conventional angiography is not available. Movement artefact from respiration and peristalsis is a common problem in the interpretation of conventional angiography; this is essentially abolished with rapid acquisition times and the use of multi-planar images to remove overlying bowel loops. Cross-sectional imaging with the ability for multi-planar reconstruction allows the accurate anatomical localization of the bleeding site, as well as an assessment of the underlying pathology: this can be used to plan therapy (embolization or surgery). The aim of this paper is to review the current use of CT in the investigation of patients with GI haemorrhage, illustrated with images from our Institution. For patients in whom GI endoscopy has failed to establish a diagnosis, we propose multi-section CT angiography as the initial imaging investigation in acute GI haemorrhage.

  2. Lung cancer perfusion at multi-detector row CT: reproducibility of whole tumor quantitative measurements.

    Science.gov (United States)

    Ng, Quan-Sing; Goh, Vicky; Fichte, Heinz; Klotz, Ernst; Fernie, Pat; Saunders, Michele I; Hoskin, Peter J; Padhani, Anwar R

    2006-05-01

    Institutional review board approval and informed consent were obtained for this study. The aim of the study was to prospectively assess, in patients with lung cancer, the reproducibility of a quantitative whole tumor perfusion computed tomographic (CT) technique. Paired CT studies were performed in 10 patients (eight men, two women; mean age, 66 years) with lung cancer. Whole tumor permeability and blood volume were measured, and reproducibility was evaluated by using Bland-Altman statistics. Coefficient of variation of 9.49% for permeability and 26.31% for blood volume and inter- and intraobserver variability ranging between 3.30% and 6.34% indicate reliable assessment with this whole tumor technique.

  3. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  4. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing [Huadong Hospital Fudan University, Department of Radiology, Shanghai (China); Zheng, Xiangpeng [Huadong Hospital Fudan University, Department of Radiation Oncology, Shanghai (China); Chen, Yan [Huadong Hospital Fudan University, Department of Pathology, Shanghai (China); Lv, Fangzhen [Huadong Hospital Fudan University, Department of Thoracic Surgery, Shanghai (China)

    2013-12-15

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  5. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT.

    Science.gov (United States)

    Jaeckle, T; Stuber, G; Hoffmann, M H K; Jeltsch, M; Schmitz, B L; Aschoff, A J

    2008-07-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT.

  6. Morphometric evaluation of subaxial cervical spine using multi-detector computerized tomography (MD-CT) scan: the consideration for cervical pedicle screws fixation

    OpenAIRE

    Chanplakorn, Pongsthorn; Kraiwattanapong, Chaiwat; Aroonjarattham, Kitti; Leelapattana, Pittavat; Keorochana, Gun; Jaovisidha, Suphaneewan; Wajanavisit, Wiwat

    2014-01-01

    Background Cervical pedicle screw (CPS) insertion is a technically demanding procedure. The quantitative understanding of cervical pedicle morphology, especially the narrowest part of cervical pedicle or isthmus, would minimize the risk of catastrophic damage to surrounding neurovascular structures and improve surgical outcome. The aim of this study was to investigate morphology and quantify cortical thickness of the cervical isthmus by using Multi-detector Computerized Tomography (MD-CT) sca...

  7. 腹腔神经节的多层螺旋CT表现%Multi-Detector CT Findings of Celiac Ganglia

    Institute of Scientific and Technical Information of China (English)

    王梅; 张龙江; 路莉; 卢光明

    2012-01-01

    Objective To study the multi-detector CT findings of celiac ganglia. Materials and Methods Abdominal non-enhanced and enhanced multi-detector CT data of 133 subjects with normal findings were retrospectively reviewed. The location, morphologic feature, and size of the celiac ganglia were recorded and measured. Results Left celiac ganglia were showed in 124 subjects, not showed in 9 subjects, while right celiac ganglia were showed in 115 subjects and not showed in 18 subjects. There were no statistical difference for the display of celiac ganglia between left and right side (93. 2% vs 86. 5% , x2 = 3. 339, P = 0. 068 ) . Celiac ganglia were identified at the level between the origins of celiac and superior mesenteric arteries. The left ganglia was located between the left adrenal gland and diaphragm, and the right were identified posteromedial to the inferior vena cava and the inside of the right adrenal gland. They were thread-like (74. 5% , 178/239) or lobulated (25. 5% , 61/239). The mean long-axis dimensions of the left and right were (26. 1 ± 12.3) mm, (29. 5 ± 9. 2 ) mm, the left celiac ganglia were smaller than the right (t = - 4. 208,P < 0.001) . The mean short-axis dimensions of the left and right ganglia were (4. 1 ±1.0) mm, (3.1±0. 9) mm,the left celiac ganglia were larger than the right (t = 13. 635, P <0. 001). Conclusion Multi-detector CT can show the location, size, morphologic feature of the celiac ganglia. The left celiac ganglia had higher display rate than right but without statistical difference.%目的 探讨腹腔神经节多层螺旋CT(MDCT)的表现.资料与方法 回顾分析133例上腹部CT平扫和增强扫描无异常患者的CT资料,记录和测量腹腔神经节的位置、形态及大小.结果 左侧腹腔神经节124例显示,9例显示不清;右侧115例显示,18例显示不清,两侧显示率的差异无统计学意义(左侧,93.2%;右侧,86.5%;x2=3.339,P=0.068).双侧腹腔神经节位于腹腔干

  8. Multi-detector CT-colonography in inflammatory bowel disease: Prospective analysis of CT-findings to high-resolution video colonoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Kjel [Institute of Diagnostic Radiology, University Hospital Duesseldorf (Germany)]. E-mail: kjel_andersen@web.de; Vogt, Christoph [Department of Gastroenterology, Hepatology and Infectiology, University Hospital Duesseldorf (Germany); Blondin, Dirk [Institute of Diagnostic Radiology, University Hospital Duesseldorf (Germany); Beck, Andreas [Institute of Informatics, Heinrich-Heine-University, Duesseldorf (Germany); Heinen, Wolfram [Institute of Diagnostic Radiology, University Hospital Duesseldorf (Germany); Aurich, Volker [Institute of Informatics, Heinrich-Heine-University, Duesseldorf (Germany); Haeussinger, Dieter [Department of Gastroenterology, Hepatology and Infectiology, University Hospital Duesseldorf (Germany); Moedder, Ulrich [Institute of Diagnostic Radiology, University Hospital Duesseldorf (Germany); Cohnen, Mathias [Institute of Diagnostic Radiology, University Hospital Duesseldorf (Germany)

    2006-04-15

    Aim: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). Materials and methods: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1 mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. Results: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. Conclusion: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity.

  9. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  10. Validity of blood flow measurement using 320 multi-detectors CT and first-pass distribution theory: a phantom study

    Science.gov (United States)

    Chen, Jun; Yu, Xuefang; Xu, Shaopeng; Zhou, Kenneth J.

    2015-03-01

    To evaluate the feasibility of measuring the myocardial blood flow using 320 row detector CT by first-pass technique. Heart was simulated with a container that was filled with pipeline of 3mm diameter; coronary artery was simulated with a pipeline of 2 cm diameter and connected with the simulated heart. The simulated coronary artery was connected with a big container with 1500 ml saline and 150ml contrast agent. One pump linking with simulated heart will withdraw with a speed of 10 ml/min, 15 ml/min, 20 ml/min, 25 ml/min and 30 ml/min. First CT scan starts after 30 s of pumpback with certain speed. The second CT scan starts 5 s after first CT scans. CT images processed as follows: The second CT scan images subtract first CT scan images, calculate the increase of CT value of simulated heart and the CT value of the unit volume of simulated coronary artery and then to calculate the total inflow of myocardial blood flow. CT myocardial blood flows were calculated as: 0.94 ml/s, 2.09 ml/s, 2.74 ml/s, 4.18 ml/s, 4.86 ml/s. The correlation coefficient is 0.994 and r2 = 0.97. The method of measuring the myocardial blood flow using 320 row detector CT by 2 scans is feasible. It is possible to develop a new method for quantitatively and functional assessment of myocardial perfusion blood flow with less radiation does.

  11. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with {sup 15}O-H{sub 2}O PET

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Naya, Masanao [Hokkaido University Graduate School of Medicine, Department of Cardiovascular Medicine, Sapporo (Japan); Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Sasaki, Tsukasa [Hokkaido University Hospital, Department of Radiology, Sapporo (Japan); Katoh, Chietsugu [Hokkaido University Faculty of Health Sciences, Sapporo (Japan); Shirato, Hiroki [Hokkaido University Graduate School of Medicine, Department of Radiation Medicine, Sapporo (Japan)

    2014-07-15

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against {sup 15}O-H{sub 2}O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFR{sub CT} in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  12. Enhancement patterns of pancreatic adenocarcinoma on conventional dynamic multi-detector row CT: Correlation with angiogenesis and fibrosis

    Institute of Scientific and Technical Information of China (English)

    Yuki Hattori; Toshifumi Gabata; Osamu Matsui; Kentaro Mochizuki; Hirohisa Kitagawa; Masato Kayahara; Tetsuo Ohta; Yasuni Nakanuma

    2009-01-01

    AIM: To evaluate retrospectively the correlation between enhancement patterns on dynamic computed tomography (CT) and angiogenesis and fibrosis in pancreatic adenocarcinoma.METHODS: Twenty-three patients with pancreatic adenocarcinoma underwent dynamic CT and tumor resection. In addition to the absolute and relative enhanced value that was calculated by subtracting the attenuation value on pre-contrast from those on contrast-enhanced CT in each phase, we defined one parameter, "tumor-aorta enhancement ratio", which was calculated by dividing enhancement of pancreatic cancer by enhancement of abdominal aorta in each phase. These enhancement patterns were correlated with the level of vascular endothelial growth factor (VEGF), microvessel density (MVD), and extent of fibrosis.RESULTS: The absolute enhanced value in the arterial phase correlated with the level of VEGF and MVD (P = 0.047, P = 0.001). The relative enhanced value in arterial phase and tumor-aorta enhancement ratio (arterial) correlated with MVD (P = 0.003, P = 0.022). Tumor-aorta enhancement ratio (arterial) correlated negatively with the extent of fibrosis (P = 0.004). The tumors with greater MVD and higher expression of VEGF tended to show high enhancement in the arterial dominant phase. On the other hand, the tumors with a larger amount of fibrosis showed a negative correlation with the grade of enhancement during the arterial phase.CONCLUSION: Enhancement patterns on dynamic CT correlated with angiogenesis and may be modified by the extent of fibrosis.

  13. Multi-Detector CT Findings of the Normal Appendix in Children: Evaluation of the Position, Diameter, and Presence or Absence of Intraluminal Gas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Woon Ju; Kim, Jong Chul [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2011-08-15

    To assess the usefulness of multi-detector CT (MDCT) with multiplanar reformations (MPR) for the evaluation of the position, diameter and presence or absence of intraluminal gas in the normal appendix in children. From 2007 to 2010, we retrospectively analyzed the MDCT images of normal appendices in 133 children, and evaluated the position, diameter, and presence or absence of intraluminal gas in the appendix. Among the 133 appendices, type I (postileal and medial paracecal position) was found in 64 children, type II (subcecal position) in 22, type III (retrocecal and retrocolic/laterocolic position) in 15, type IV (preileal and medial colic position) in 16, and type V (lower pelvic position) in 16 children. The mean diameter was 5.8 mm {+-} 1.2 (SD) (range; 3.2-8.7 mm). There was a high correlation between the appendiceal diameter and age (p = 0.000).There was no statistically significant difference in the appendiceal diameter between boys and girls (p = 0.470). Intraluminal gas was found in 115 appendices and there was no statistically significant correlation between the appendiceal diameter and intraluminal gas (p = 0.502). The MDCT with MPR was useful for the evaluation of the normal appendices in children. The procedure may be useful for the diagnosis of equivocal or unusual appendicitis in children.

  14. Can outer-to-outer diameter be used alone in diagnosing appendicitis on 128-slice MDCT?

    Institute of Scientific and Technical Information of China (English)

    Jamal; Yaqoob; Muhammad; Idris; Muhammad; Shahbaz; Alam; Nazia; Kashif

    2014-01-01

    AIM: To assess the frequency of visualization, position and diameter of normal appendix on 128-slice multidetector computed tomography(MDCT) in adult population.METHODS: Retrospective cross sectional study conducted at Radiology Department, Dallah Hospital, Riyadh, Saudi Arabia from March 2013 to October 2013. Non-enhanced computed tomography scans of abdomen and pelvis of 98 patients presenting with hematuria(not associated with abdominal pain, fever or colonic disease) were reviewed by two radiologists, blinded to patient history. The study group included 55 females and 43 males with overall mean age of 54.7 years(range 21 to 94 years). The coronal reformatted images were reviewed in addition to the axial images. The frequency of visualization of appendix was recorded with assessment of position, diameter and luminal contents.RESULTS: The appendix was recorded as definitely visualized in 99% of patients and mean outer-to-outer diameter of the appendix was 5.6 ± 1.3 mm(range 3.0-11.0 mm).CONCLUSION: MDCT with its multiplanar reformation display is extremely useful for visualization of normal appendix. The normal appendix is very variable in its position and diameter. In the absence of other signs, the diagnosis of acute appendix should not be made solely on outer-to-outer appendiceal diameter.

  15. Liver tumour segmentation using contrast-enhanced multi-detector CT data: performance benchmarking of three semiautomated methods

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jia-Yin [National University of Singapore, Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, Singapore (Singapore); Agency for Science, Technology and Research, Institute for Infocomm Research, Singapore (Singapore); Wong, Damon W.K.; Tian, Qi; Xiong, Wei; Liu, Jimmy J. [Agency for Science, Technology and Research, Institute for Infocomm Research, Singapore (Singapore); Ding, Feng; Venkatesh, Sudhakar K.; Qi, Ying-Yi [National University of Singapore, Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, Singapore (Singapore); Leow, Wee-Kheng [National University of Singapore, School of Computing, Singapore (Singapore)

    2010-07-15

    Automatic tumour segmentation and volumetry is useful in cancer staging and treatment outcome assessment. This paper presents a performance benchmarking study on liver tumour segmentation for three semiautomatic algorithms: 2D region growing with knowledge-based constraints (A1), 2D voxel classification with propagational learning (A2) and Bayesian rule-based 3D region growing (A3). CT data from 30 patients were studied, and 47 liver tumours were isolated and manually segmented by experts to obtain the reference standard. Four datasets with ten tumours were used for algorithm training and the remaining 37 tumours for testing. Three evaluation metrics, relative absolute volume difference (RAVD), volumetric overlap error (VOE) and average symmetric surface distance (ASSD), were computed based on computerised and reference segmentations. A1, A2 and A3 obtained mean/median RAVD scores of 17.93/10.53%, 17.92/9.61% and 34.74/28.75%, mean/median VOEs of 30.47/26.79%, 25.70/22.64% and 39.95/38.54%, and mean/median ASSDs of 2.05/1.41 mm, 1.57/1.15 mm and 4.12/3.41 mm, respectively. For each metric, we obtained significantly lower values of A1 and A2 than A3 (P < 0.01), suggesting that A1 and A2 outperformed A3. Compared with the reference standard, the overall performance of A1 and A2 is promising. Further development and validation is necessary before reliable tumour segmentation and volumetry can be widely used clinically. (orig.)

  16. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  17. Multi-detector CT perfusion

    Directory of Open Access Journals (Sweden)

    Ashraf M. Enite

    2016-09-01

    Conclusion: CTP is a promising non-invasive technique assessing the efficacy, predicting early response to local treatment therapies and monitoring tumor recurrence. It assesses the degree of post therapy tumor perfusion especially the degree of arterialization.

  18. The Value of Multi-detector row CT in Gastroenteropathy and Application of Contrast Agents%MDCT在胃肠道检查中的价值及对比剂的应用

    Institute of Scientific and Technical Information of China (English)

    鲁桂青; 陈克敏; 刘林祥

    2007-01-01

    胃肠道疾患在过去以传统的检查方法 (主要为消化道钡剂透视及纤维内窥镜)为主,随着多层螺旋CT(multi-detector row CT,MDCT)的快速发展以及各种不同腔内对比剂的研究与应用,CT对胃肠道的检查价值显著提高。

  19. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  20. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    Energy Technology Data Exchange (ETDEWEB)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T. [Dept. Medical Radiology, Inst. of Diagnostic Radiology, Univ. Hospital Zurich (Switzerland)

    2004-04-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P<0.05). The summary scores for visualization of bronchial segments for different diastolic reconstructions did not differ significantly. The effective radiation dose and the SNR were significantly higher with the ECG-gated acquisition technique (P<0.05). Conclusion: The bronchial tree is significantly better visualized when using non-ECG-gated MDCT compared to ECG-gated MDCT. Additionally, non-ECG-gated techniques require less radiation exposure. Thus, the current retrospective ECG-gating technique does not provide any additional benefit for 3D visualization of the bronchial tree and VB. (orig.) [German] Ziel: Untersuchung des Einflusses der retrospektiven EKG-Synchronisierung auf

  1. Quantitative hepatic CT perfusion measurement: Comparison of Couinaud's hepatic segments with dual-source 128-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xuan [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Xue, Hua-dan, E-mail: bjdanna95@hotmail.com [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Jin, Zheng-yu, E-mail: jin_zhengyu@163.com [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China); Su, Bai-yan; Li, Zhuo; Sun, Hao; Chen, Yu; Liu, Wei [The Department of Radiology, Peking Union Medical College Hospital, Dongcheng District, Beijing, 100730 (China)

    2013-02-15

    Purpose: To compare the quantitative liver computed tomography perfusion (CTP) differences among eight hepatic segments. Materials and methods: This retrospective study was based on 72 acquired upper abdomen CTP scans for detecting suspected pancreas tumor. Patients with primary or metastatic liver tumor, any focal liver lesions except simple cyst (<3 cm in diameter), history of liver operation or splenectomy, evidence of liver cirrhosis or invasion of portal vein were excluded. The final analysis included 50 patients (M:F = 21:29, mean age = 43.2 years, 15–76 years). Arterial liver perfusion (ALP), portal-venous perfusion (PVP), total hepatic perfusion (THP = ALP + PVP), and hepatic perfusion index (HPI) of each hepatic segment were calculated and compared by means of one-way analysis of variance (ANOVA) and the Bonferonni correction method. Results: Compared to hepatic segments 5, 6, 7 and 8, segments 2 and 3 showed a tendency of higher ALPs, lower PVPs, and higher HPIs, most of which were statistically significant (p < 0.05). Hepatic segments 1 and 4 had higher mean values of ALP and HPI and lower mean values of PVP than segments 5, 6, 7 and 8 as well, although no significant differences were detected except for ALP and HPI for liver segments 1 and 7 (p = 0.001 and 0.035 respectively), and ALP for liver segments 1 and 5 (p = 0.039). Higher ALP and HPI were showed in hepatic segment 3 compared to segment 4 (p = 0.000 and 0.000 respectively). No significant differences were found for THP among eight segments. Conclusions: Intra-hepatic perfusion differences exist in normal hepatic parenchyma especially between lateral sector (segments 2 and 3) and right lobe (segments 5, 6, 7 and 8). This might have potential clinical significance in liver-perfusion-related protocol design and result analysis.

  2. Diagnostic Value of Brain Perfusion Imaging with 64 Multi-Detector Spiral CT in Early Cerebral Infarction%64排螺旋 CT 脑灌注成像对早期脑梗死的诊断价值

    Institute of Scientific and Technical Information of China (English)

    奚彬; 盛伟华; 唐建伟; 黄松; 宋黎涛

    2014-01-01

    目的:探讨64排螺旋 CT 脑灌注成像(CT perfusion imaging,CTP)对早期脑梗死的诊断价值。方法:临床拟诊早期脑梗死患者38例,均在症状出现24 h 内行头颅 CT 平扫及 CTP 检查。将脑梗死核心区、缺血半暗带(ischemic penumbra,IP)区与健侧对应区的情况做对比分析。结果:38例患者中,15例头颅 CT 平扫发现可疑脑梗死区,主要位于大脑半球,表现为密度轻度减低、局部脑沟稍变浅等;其余23例患者 CT 平扫未发现异常。38例患者的 CTP 检查均发现灌注异常区,表现为脑梗死区脑血流量(cerebral blood flow,CBF)与脑血容量(cerebral blood volume,CBV)均较健侧对应区明显下降,对比剂平均通过时间(mean transit time,MTT)较健侧对应区缩短,对比剂达峰时间(time to peak,TTP)较健侧对应区明显延长,差异均有统计学意义(P <0.01)。早期脑梗死患者 IP 区与梗死核心区比较,CBF、CBV、MTT 及 TTP 差异均有统计学意义(P <0.01);IP区与健侧对应区比较,CBF、MTT、TTP 差异均有统计学意义(P <0.05、0.01),CBV 差异无统计学意义(P >0.05)。获得随访的18例患者中,经积极溶栓等治疗后梗死区缩小6例,梗死区消失5例,仅表现为梗死区 TTP 和 MTT 延长、CBF 和 CBV 变化不大3例,梗死区无明显变化4例。结论:64排螺旋 CTP 检查可以准确地提示早期脑梗死。%Objective:To explore the diagnostic value of CT perfusion imaging(CTP)with 64 multi-detector spiral CT in early cerebral infarction.Methods:A total of 38 patients with suspected early cerebral infarction underwent plain CT and CTP within 24 h after the onset of related symptoms.The imaging results in infarction core area,ischemic penumbra (IP) and the contralateral normal region were comparatively analyzed.Results:Early cerebral infarction,mainly in cerebral hemispheres, were suspected

  3. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Zhao, Yingru; Snijder, R.A.; van Ooijen, P.M.; de Jong, P.A.; Oudkerk, M.; de Bock, G.H.; Vliegenthart, R.; Greuter, M.J.

    2013-01-01

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 H

  4. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Tom Anthony; Arthurs, Owen John; Calder, Alistair Duncan [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Radiology, London (United Kingdom); Muthialu, Nagarajan [Great Ormond Street Hospital for Children NHS Foundation Trust, Department of Cardiothoracic surgery, London (United Kingdom)

    2014-02-15

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects (''rib gaps''). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia. (orig.)

  5. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    Science.gov (United States)

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  6. Multi-detector CT angiography for the assessment of anterior spinal artery and artery of Adamkiewicz patency in patients suspected of having thoracic aortic pathology

    Institute of Scientific and Technical Information of China (English)

    Shaohong ZHAO; Laura Logan; Pamela Schraedley; Geoffrey D.Rubin

    2006-01-01

    Objective To evaluate the visualization of the anterior spinal artery (ASA) and the artery of Adamkiewicz (AKA) as well as the affecting factors for the detection rate using multidetector row CT (MDCT). Methods Ninety-nine consecutive patients (31 women and 68 men; age range, 25-90 years; average age 61.3 years) with suspicion for thoracic aortic lesions necessitating surgical intervention (31 aortic aneurysm, 45 dissection, 5 intramural hematoma, and 18 normal), underwent 16-slice MDCT angiography from the aortic arch to the aortic bifurcation. Transverse sections, multiplanar reformations (MPR) and thin maximum intensity projections (MIP) were used to assess the ASA and AKA. The level of the ASA and AKA origins and CT acquisition parameters were recorded. The contrast-to-noise ratio (CNR) of the image, an index of the mass of the T11 body (vertebral mass index), the subcutaneous fat thickness,and the CT value within the aortic arch and at the T11 level were measured. The detection of the ASA and AKA was evaluated relative to the acquisition parameters, scan characteristics, and aortic lesion type. Differences were assessed with Wilcoxon rank-sum and t tests. Results The ASA was visualized in 51 patients (52%) and the AKA in 18 patients (18 %). The ASA was identified in 36/67 (54%)patients with 1.25 mm thickness and in15/32 (47%) patients with 2.5-3.0 mm thickness. This difference did not achieve significance (P=0.13). The detection rate of the ASA and the AKA was influenced by vertebral mass index and the CNR (P<0.05). The amount of subcutaneous fat affected the detection rate of the ASA (P<0.05) but not the AKA. In CT scans with ASA detection, the mean CT values in the aorta at the arch and at T11 were 360 and 358 HU, respectively; whereas in CT scans without ASA detection, the CT values in the aorta at the arch and at T11 were lower (297 and 317 HU, respectively; both P<0.05). Conclusion The ASA and AKA were less frequently detected in our cohorts than

  7. Value of multi-detector CT angiography in Takayasu arteritis%多排螺旋CT对多发性大动脉炎的诊断价值

    Institute of Scientific and Technical Information of China (English)

    陈海雄; 胡秋根; 李景雷

    2014-01-01

    目的 探讨多排螺旋CT(MDCT)在多发性大动脉炎中的诊断价值。方法 回顾性分析32 例经临床确诊为大动脉炎患者的MDCT 资料及实验室检查,图像后处理方法包括多平面重建(MPR)、曲面重建(CPR)、最大密度投影(MIP)、容积再现(VR),实验室检查主要包括红细胞沉降率(ESR)和C 反应蛋白(CRP)。结果 按照Lupi-Herrea 分类法,Ⅰ型10 例,Ⅱ型9 例,Ⅲ型8 例,Ⅳ型5 例;共累及血管134 支,狭窄- 阻塞型112 支;扩张型8 支;混合型14 支。受累血管管壁最大厚度范围为1.3~8.6 mm(平均3.65±1.58),活动期管壁最大厚度约2.7~8.6 mm(平均5.24±1.59),明显大于非活动期1.3~6.0 mm (平均2.93±0.92)(P<0.05)。增强扫描活动期管壁强化8 例(80.0%),非活动期管壁轻度强化2 例(9.0%),非活动期管壁钙化 7 例(31.8%)。结论 MDCT 能准确判断多发性大动脉炎的分型、分期及病变范围,可作为其首选检查方法。%ObjectiveTo investigate the clinical value of multi-detector computed tomography(MDCT)in the diagnosis of Takayasu's arteritis.Methods MDCT, erythrocyte sedimentation rate(ESR)and C-reactive protein(CRP)levels of 32 patients with Takayasu’s arteritis were analyzed retrospectively. Image processing included multi-planar reformation(MPR), maximum intensity projection (MIP), and volume rendering reconstruction(VR).Results The patients were classified Lupi-Herrea type I(10), type II(9), type III(8) and type IV(5). Of 134 abnormal vessels, 112 were stenotic or occlusive, 8 were dilated and 14 were mixed. The vessel wall thickness was 1.3-8.6 mm(average 3.65±1.58 mm)with significantly(P<0.05)thicker walls in the active phase(2.7-8.6 mm)than that in the resting phase(1.3-6.0 mm). There was heterogeneous contrast enhancement of the vessel walls in the active phase(80.0%), mild enhancement(9.0%)and calcification (31.8%)in the resting

  8. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Snijder, Roland A.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Groningen (Netherlands)

    2013-01-15

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 {+-} 14.0 % for nodules of any density, and 26.4 {+-} 15.5 % for solid nodules, compared with 7.6 {+-} 8.5 % (P < 0.01) semi-automatically. In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  9. Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: impact on surgical procedure

    Energy Technology Data Exchange (ETDEWEB)

    Frericks, Bernd B.J. [Hanover Medical School, Departments of Radiology and Surgery, Hannover (Germany); University of Berlin, Department of Radiology, Berlin (Germany); Charite - University Medicine Berlin, Department of Radiology and Nuclear Medicine, Berlin (Germany); Kirchhoff, Timm D.; Shin, Hoen-Oh; Stamm, Georg; Merkesdal, Sonja; Abe, Takehiko; Galanski, Michael [Hanover Medical School, Departments of Radiology and Surgery, Hannover (Germany); Hanover Medical School, Department of Diagnostic Radiology, Hannover (Germany); Schenk, Andrea; Peitgen, Heinz-Otto [Hanover Medical School, Departments of Radiology and Surgery, Hannover (Germany); MeVis - Center for Medical Diagnostic Systems and Visualization, Bremen (Germany); Klempnauer, Juergen [Hanover Medical School, Departments of Radiology and Surgery, Hannover (Germany); Hanover Medical School, Department of Visceral- and Transplantation Surgery, Hannover (Germany); Nashan, Bjoern [Hanover Medical School, Departments of Radiology and Surgery, Hannover (Germany); Hanover Medical School, Department of Visceral- and Transplantation Surgery, Hannover (Germany); Dalhousie University, Multi Organ Transplant Program, Halifax, Nova Scotia (Canada)

    2006-12-15

    The purpose was to assess the volumes of the different hepatic territories and especially the drainage of the right paramedian sector in adult living donor liver transplantation (ALDLT). CT was performed in 40 potential donors of whom 28 underwent partial living donation. Data sets of all potential donors were postprocessed using dedicated software for segmentation, volumetric analysis and visualization of liver territories. During an initial period, volumes and shapes of liver parts were calculated based on the individual portal venous perfusion areas. After partial hepatic congestion occurring in three grafts, drainage territories with special regard to MHV tributaries from the right paramedian sector, and the IRHV were calculated additionally. Results were visualized three-dimensionally and compared to the intraoperative findings. Calculated graft volumes based on hepatic venous drainage and graft weights correlated significantly (r=0.86,P<0.001). Mean virtual graft volume was 930 ml and drained as follows: RHV: 680 ml, IRHV: 170 ml (n=11); segment 5 MHV tributaries: 100 ml (n=16); segment 8 MHV tributaries: 110 ml (n=20). When present, the mean aberrant venous drainage fraction of the right liver lobe was 28%. The evaluated protocol allowed a reliable calculation of the hepatic venous draining areas and led to a change in the hepatic venous reconstruction strategy at our institution. (orig.)

  10. Value of multi-detector spiral CT angiography in the assessment of coronary artery elasticity%多层螺旋CT血管成像在冠状动脉弹性研究中的价值

    Institute of Scientific and Technical Information of China (English)

    许开元; 肖丹丹; 何祥发; 贾艳莲; 高芳琴; 张雪林

    2015-01-01

    Objective To study the efficacy of multi-detector spiral CT angiography (CTA) for evaluating coronary artery elasticity. Methods CTA was performed on 133 patients from August 2010 to April 2013..Diameter changes of 412 segment of coronary arteries in the systolic and diastolic phases were measured by CTA and digital subtraction angiography (DSA)..Coronary artery elastic parameters and elasticity index (ERI) were analyzed and correlated with DSA results. Results The ERI was positively correlated with remodeling on DSA (P0) in 46 coronary artery segments,.no significant remodeling (ERI=0) in 32 segments,.and negative remodeling (ERI<0) in 71 segments. Conclusion Multi-slice CTA can reflect the elasticity of coronary vessel walls. Compared with the results of DSA , coronary artery elasticity index correlates with the remodeling of coronary artery plaques and allows assessment of plaque instability.%目的:评价多层螺旋CT血管成像在冠状动脉弹性重塑中的价值。方法选取2010年8月~2013年4月本院行冠状动脉 CT 血管成像检查及冠脉 DSA 检查患者资料共133例,通过测量冠状动脉412节段在收缩期、舒张期的动脉管径变化,并与DSA对照,分析冠状动脉斑块处血管弹性,计算冠状动脉弹性重塑指数,并分析冠状动脉弹性重塑指数与DSA结果的相关性。结果冠状动脉弹性重塑指数(ERI)与DSA结果呈正相关,(P<0.05, r=0.402)。斑块处冠状动脉弹性正性重塑(ERI>0)46节段,无明显重塑者(ERI=0)32节段,负性重塑者(ERI<0)71节段。结论多层螺旋 CT 血管成像可较好反映正常冠状动脉血管壁弹性。与冠状动脉DSA结果相比,斑块处冠状动脉弹性重塑指数可反映斑块处冠状动脉弹性重塑情况,评价斑块稳定性。

  11. Diagnostic value of appendicolith in appendicitis with multi-detector CT%阑尾石多排螺旋CT征象诊断阑尾炎的价值

    Institute of Scientific and Technical Information of China (English)

    戚乐; 向军益; 戴平丰; 丁建平

    2012-01-01

    Objective To investigate the diagnostic value of appendicolith in appendicitis with multi-detector CT. Methods MDCT findings of 87 cases of appendicitis and 55 cases of non-appendicitis confirmed by surgery and clinical follow-up were retrospectively analysed. The relationship between appendicolith and appendicitis was statistically analysed. Results The appendicolith sign in MDCT was positive in 43 cases(33 cases of appendicitis and 10 cases of non-appendicitis). The appendicolith sign was not of significant difference on CT images in differential diagnosis for appendicitis and non-appendicitis, including pathologically classified (P>0. 05). The accuracy was 54. 9% , the sensitivity was 37. 9% , and the specificity was 81. 8% in diagnosing appendicititis with appendicolith sign. Obstructive appendicolith sign in 12 cases (short diameter>5 mm, located in the appendix proximal) was more seen in appendicitis group,but could identify pathologically classified(P>0. 05). The extraluminal appendicolith sign in 5 cases was seen only in gangrenous appendicitis (P<0. 05). Conclusion Obstructive appendicolith sign is helpful in diagnosis of appendicitis, and extraluminal appendicolith sign has high specificity in diagnosis of gangrenous appendicitis.%目的 探讨阑尾石MDCT征象诊断阑尾炎的价值.方法 回顾分析经手术和临床随访证实的87例阑尾炎和55例非阑尾炎患者的MDCT影像表现.统计分析阑尾石征象与阑尾炎的关系.结果 阑尾石征象阳性43例(阑尾炎患者33例,非阑尾炎患者10例),诊断阑尾炎的准确性、敏感性和特异性分别为54.9%、37.9%和81.8%,在阑尾炎组和非阑尾炎组中出现的概率无显著差异性,亦不能鉴别阑尾炎的病理分型(P>0.05).12例梗阻性阑尾石征象(短径≥5 mm,位于阑尾近端)多见于阑尾炎组,但不能鉴别阑尾炎病理分型(P>0.05).5例腔外阑尾石征象仅见于坏疽性阑尾炎(P<0.05).结论 梗阻性阑尾石征象有助于

  12. 多排螺旋CT 诊断小网膜囊病变的价值%Diagnostic value of multi-detector CT for abnormalities in lesser omental bursa

    Institute of Scientific and Technical Information of China (English)

    成峰; 吴凯宏; 李孝虎

    2011-01-01

    目的 探讨小网膜囊正常解剖及病变的多排螺旋CT(MDCT)表现,评价小网膜囊病变的CT 诊断价值.方法 对24 例小网膜囊病变进行上腹部CT 平扫及三期增强扫描检查,均经手术病理证实.结果 小网膜囊病变中:原发肿瘤6 例(神经鞘瘤2 例,平滑肌瘤1 例,血管瘤1 例,脂肪肉瘤1 例,淋巴瘤1 例),CT 表现为小网膜囊内边界清晰肿块.邻近脏器的良、恶性肿瘤8 例(胰头癌4 例,肝左叶肝细胞癌2 例,胃间质瘤2 例),CT 表现为小网膜囊肿块与邻近相应肿瘤边界不清.转移性肿瘤2 例.结核1 例,CT 表现多个病灶融合,内见钙化.积液(腹水漏出液、炎性渗出液、脓液、血液、胆汁、淋巴液)6 例;假性囊肿1 例;CT 均表现为小网膜囊内液性密度灶.结论 多排螺旋CT对小网膜囊病变具有重要的诊断价值.%Objective To investigate the normal CT anatomy and diagnostic value of CT for abnormalities of lesser omental bursa. Methods Twenty-four patients with 6 primary neoplasms (2 neurinomas, 1 leiomyoma, 1 cavernous hemangioma, 1 liposarcoma, 1 lymphoma), 8 local spread from adjacent benign or malignant neoplasms (4 carcinomas of head of pancreas, 2 left hepatic tumors, 2 gastrointestinal stromal tumors of the stomach), 2 metastatic tumors, 1 tuberculosis, 6 fluid collections (transudate ascites, inflammatory infiltrate, pus, blood, bile, lymph), lpseudocyst were enrolled in the study. All of the lesions were confirmed by operation and pathology. The pre- and post-contrast abdominal CT scans were reviewed. Results The borders of the 6 primary neoplasms were well-defined on CT whereas the 8 benign or malignant neoplasms originating from adjacent structures were contiguous with the primary tumors. CT showed multiple aggregated lesions on 2 patients with metastases and 1 patient with tuberculosis. The 6 fluid collections and lpseudocyst displayed fluid density within lesser omental bursa on CT. Conclusion CT is valuable in

  13. 自发性腹腔干夹层的 MSCT 血管成像表现%Imaging manifestations of spontaneous celiac artery trunk dissection with multi-detector CT angiography

    Institute of Scientific and Technical Information of China (English)

    宁辉; 张龙江

    2015-01-01

    Objective:To summarize the multi-detector CT angiography (MDCTA)manifestations of spontaneous ce-liac artery trunk dissection.Methods:The clinical and MDCTA manifestations of 14 patients with spontaneous celiac artery trunk dissection were retrospectively analyzed.Results:Of the 14 patients,10 patients (71.4%,10/14)had spontaneous ce-liac artery trunk dissection,4 patients (28.6%,4/14)had both celiac artery trunk and superior mesenteric artery dissec-tion.Intimal plaque,orifice of dissection,true and false lumen were displayed in all involved 14 celiac artery trunk and 4 su-perior mesenteric artery dissections.Three dissected arteries were associated with thrombosis,2 dissected arteries with mu-ral calcification,2 dissected arteries with adjacent hematoma,and 1 with splenic infarct.Of the 14 celiac artery trunk dissec-tion,6 associated with aneurymal protrusion,and all 4 superior mesenteric artery dissection had aneurysmal protrusion asso-ciated.Two patients had celiac artery Digital Subtraction Angiography performed,the manifestations were similar to that of MSCT angiography.Intra-stent thrombosis was found in one patient underwent stent implantation.Conclusion:MDCT angi-ography can detect the pathology of celiac artery trunk dissection sensitively,which might used as the first choice modality for the diagnosis and follow up of this disease entity.%目的:总结自发性腹腔干夹层的 MSCT 血管成像表现。方法:回顾性分析14例自发性腹腔干夹层患者的临床及 MSCT 血管成像表现。结果:14例患者中自发性腹腔干夹层10例(71.4%,10/14),腹腔干和肠系膜上动脉夹层4例(28.6%,4/14)。14条腹腔干血管和4条肠系膜上动脉夹层均显示了内膜片、破口及真假腔,3条血管夹层合并血栓,2条夹层血管合并钙化,2例患者合并周围血肿,1例合并脾梗死。14条腹腔干夹层中6条血管夹层伴有动脉瘤样突起,4条肠系膜上动脉夹层

  14. Instrumentation for multi-detector arrays

    Indian Academy of Sciences (India)

    R K Bhowmik

    2001-07-01

    The new generation of detector arrays require complex instrumentation and data acquisition system to ensure increased reliability of operation, high degree of integration, software control and faster data handling capability. The main features of some of the existing multi-detector arrays like MSU 4 array, Gammasphere and Eurogam are summarized. The instrumentation for the proposed INGA array in India is discussed.

  15. Advanced Gastric Cancer: Differentiation of Borrmann Type IV versus Borrmann Type III by Two-Phased Dynamic Multi-Detector Row CT with Use of the Water Filling Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Yu, Jeong Sik; Lee, Sang Min; Kim, Joo Hee; Chung, Jae Joon; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kang, Hae Youn [CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2013-02-15

    To characterize Borrmann type IV from Borrmann type III advanced gastric cancer (AGC) by two-phased multi-detector row computed tomography (MDCT) using the water filling method. A total of 143 patients (pathologically confirmed Borrmann type III and IV - 100 and 43 patients), who underwent preoperative MDCT, were enrolled. Two radiologists, retrospectively and independently, determined tumor enhancement pattern using a 5-grade scale without clinical information. A weighted kappa test was applied for interobserver variability. The score of tumor enhancement pattern correlated with Borrmann type as determined by Spearman's correlation coefficient. The accuracy of differentiation of Borrmann type using MDCT was determined by receiver operating characteristic curves. Interobserver agreement (weighted kappa = 0.683) was substantial. The tumor enhancement pattern score showed a significant correlation with Borrmann type (reviewer 1, r = 0.591, p < 0.001; reviewer 2, r = 0.616, p < 0.001). The accuracy for differentiation of Borrmann type on MDCT was 0.86 (p < 0.001) in both reviewers. The sensitivity and specificity of the diagnosis of Borrmann type IV were 79% and 82% in reviewer 1, and 88% and 78% in reviewer 2, respectively. Dual-phased MDCT using the water filling method can differentiate between Borrmann type IV and III AGC with high accuracy.

  16. Double Chooz Improved Multi-Detector Measurements

    CERN Document Server

    CERN. Geneva

    2016-01-01

    The Double Chooz experiment (DC) is a reactor neutrino oscillation experiment running at Chooz nuclear power plant (2 reactors) in France. In 2011, DC first reported indication of non-zero θ13 with the far detector (FD) located at the maximum of oscillation effects (i.e. disappearance), thus challenging the CHOOZ non-observation limit. A robust observation of θ13 followed in 2012 by the Daya Bay experiments with multiple detector configurations. Since 2015 DC runs in a multi-detector configuration making thus the impact of several otherwise dominating systematics reduce strongly. DC’s unique almost "iso-flux" site, allows the near detector (ND) to become a direct accurate non-oscillation reference to the FD. Our first multi-detector results at MORIOND-2016 showed an intriguing deviation of θ13 with respect to the world average. We will address this issue in this seminar. The combined "reactor-θ13" measurement is expected to ...

  17. Distant metastases and synchronous second primary tumors in patients with newly diagnosed oropharyngeal and hypopharyngeal carcinomas: evaluation of {sup 18}F-FDG PET and extended-field multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Shu-Hang; Ko, Sheung-Fat; Chin, Shu-Chyn [Chang Gung University, Department of Molecular Imaging Center and Diagnostic Radiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan (China); Chan, Sheng-Chieh; Yen, Tzu-Chen [Chang Gung University, Department of Nuclear Medicine, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan (China); Liao, Chun-Ta; Huang, Shiang-Fu [Chang Gung University, Department of Otorhinolaryngology, Chang Gung Memorial Hospital, Taoyuan (China); Chang, Joseph Tung-Chieh; Lin, Chin-Yu. [Chang Gung Memorial Hospital and Chang Gung University, Department of Radiation Oncology, Taoyuan (China); Wang, Hung-Ming [Chang Gung University, Department of Medical Oncology, Chang Gung Memorial Hospital, Taoyuan (China)

    2008-11-15

    Patients with oropharyngeal or hypopharyngeal squamous cell carcinoma (SCC) have a high risk of having distant metastases or second primary tumors. We prospectively evaluate the clinical usefulness of {sup 18}F-fluoro-2-deoxyglucose positron emission tomography ({sup 18}F-FDG PET), extended-field multi-detector computed tomography (MDCT), and their side-by-side visual correlation for the detection of distant malignancies in these two tumors at presentation. A total of 160 patients with SCC of the oropharynx (n = 74) or hypopharynx (n=86) underwent {sup 18}F-FDG PET and extended-field MDCT to detect distant metastases or second primary tumors. Suspected lesions were investigated by means of biopsy, clinical, or imaging follow-up. Twenty-six (16.3%) of our 160 patients were found to have distant malignancy. Diagnostic yields of {sup 18}F-FDG PET and MDCT were 12.5% and 8.1%, respectively. The sensitivity of {sup 18}F-FDG PET for detection of distant malignancies was 1.5-fold higher than that of MDCT (76.9% vs. 50.0%, P=0.039), while its specificity was slightly lower (94.0% vs. 97.8%, P=0.125). Side-by-side visual correlation of MDCT and {sup 18}F-FDG PET improved the sensitivity and specificity up to 80.8% and 98.5%, respectively, leading to alteration of treatment in 13.1% of patients. A significant difference in survival rates between its positive and negative results was observed. {sup 18}F-FDG PET and extended-field MDCT had acceptable diagnostic yields for detection of distant malignancies in untreated oropharyngeal and hypopharyngeal SCC. {sup 18}F-FDG PET was 1.5-fold more sensitive than MDCT, but had more false-positive findings. Their visual correlation improved the diagnostic accuracy, treatment planning, and prognosis prediction. (orig.)

  18. Comparison between multi-detector row CT angiography and Doppler ultrasound on detecting carotid artery wall thickness%多层螺旋CT与Doppler超声对颈动脉壁层厚度的对比性研究

    Institute of Scientific and Technical Information of China (English)

    赵刚; 查云飞; 王弘; 洪玮; 邱晓明; 王珍; 肖友梅

    2013-01-01

    Objective To explore the relationship and consistency between multi-detector row computed tomography angiography (MDCTA) and color Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and intima-media thickness (IMT). Methods CAWT and IMT of 38 subjects were measured using MDCTA and CD-US, respectively. Linear correlation analysis was performed to analyze the correlation between the results from CAWT and IMT,and Bland-Altman statistics was employed to analyze the consistency between them. Results The IMT value measured by CD-US was (0.85+0.16) mm, and the CAWT value measured by MDCTA was (0.87.± 0.18) mm (P > 0.05), and there was a high degree of correlation between them (correlation coefficient was 0.958,P< 0.01). An excellent consistency between CAWT and IMT was found by Bland-Altman plot, with a bias of 0.026 mm and the limit of consistency from -0.023 to 0.075. Conclusions There were significant correlation and consistency between MDCTA and CD-US in detecting CAWT and IMT. As a more objective and comprehensive new method, MDCTA can replace CD-US in the evaluation of early carotid atherosclerosis.%目的:探讨多层螺旋CT血管造影(MDCTA)和彩色多普勒超声(CD-US)在检测颈总动脉壁厚度(CAWT)和颈总动脉内膜-中层厚度(IMT)中的相关性和一致性.方法:应用MDCTA和CD-US分别对38例受试者颈总动脉的CAWT和IMT进行检测,用Pearson直线相关分析比较CAWT和IMT的相关性,用Bland-Altman分析比较两者的一致性.结果:MDCTA测量的颈总动脉CAWT为(0.87±0.18)mm,CD-US测量的颈总动脉IMT为(0.85±0.16)mm,两者比较无统计学差异,有高度相关性,相关系数为0.958,P<0.01,Bland-Altman分析两者间存在良好一致性,偏倚为0.026 mm,一致性界限为-0.023 ~ 0.075.结论:MDCTA和CD-US在检测颈总动脉CAWT和IMT时存在良好的相关性和一致性,MDCTA可以替代CD-US,作为一种评价颈动脉早期粥样硬化的更加客观全面的新方法.

  19. Improvement Techniques and Experiment Research of Multi-detector of Multi-slice CT%对多层CT的多排探测器的改进技术及实验研究

    Institute of Scientific and Technical Information of China (English)

    苏重清; 刘东红; 杨立国; 乔驰; 陶行成; 崔力元; 郑伟; 郭媛媛

    2013-01-01

    Objective To design a new kind of multidetector for multi-slice CT, so as to decrease X-ray dosage and increase resolution. Methods Laid additional detectors under the detectors of CT, to obtain new X-ray energy and new resolution data through the upper detectors and make various images with original detector data. Results Laid a layer of X-ray attenuation material on the present detectors of CT as the first layer detector and regarded the present detector as the second layer detector in the design to scan, the second layer detector data is testified available. Conclusion Through simulating tests on present CT scanner, the design is testified to be feasible.%目的 设计一种新型多层CT机的多排探测器,降低X线剂量和提高分辨率.方法在CT探测器下面再加探测器,接收穿透上层探测器的X线获得能量与分辨率不同的额外数据,和原来探测器数据做各种形式的叠加成像.结果在现有CT探测器上加X线衰减层模拟第1层探测器而视现有CT探测器为本设计的第2层探测器扫描,证明了第2层探测器的数据可用.结论通过在现有CT上的模拟实验,证明此设计是可行的.

  20. Electrocardiographically triggered CT angiography of the whole aorta and coronary arteries with high-pitch dual-source CT

    Institute of Scientific and Technical Information of China (English)

    张楠

    2013-01-01

    Objective To investigate the feasibility of comprehensive assessment of the whole aorta and coronary arteries(CA)simultaneously with high-pitch128-slice dualsource CT ECG-gated FLASH protocol.Methods A totalof 48 consecutive patients with suspected aortic diseases

  1. Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Rompel, Oliver; Janka, Rolf; Lell, Michael M.; Uder, Michael; Hammon, Matthias [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); Gloeckler, Martin; Dittrich, Sven [University Hospital Erlangen, Department of Pediatric Cardiology, Erlangen (Germany); Cesnjevar, Robert [University Hospital Erlangen, Department of Pediatric Cardiac Surgery, Erlangen (Germany)

    2016-04-15

    Many technical updates have been made in multi-detector CT. To evaluate image quality and radiation dose of high-pitch second- and third-generation dual-source chest CT angiography and to assess the effects of different levels of advanced modeled iterative reconstruction (ADMIRE) in newborns and children. Chest CT angiography (70 kVp) was performed in 42 children (age 158 ± 267 days, range 1-1,194 days). We evaluated subjective and objective image quality, and radiation dose with filtered back projection (FBP) and different strength levels of ADMIRE. For comparison were 42 matched controls examined with a second-generation 128-slice dual-source CT-scanner (80 kVp). ADMIRE demonstrated improved objective and subjective image quality (P <.01). Mean signal/noise, contrast/noise and subjective image quality were 11.9, 10.0 and 1.9, respectively, for the 80 kVp mode and 11.2, 10.0 and 1.9 for the 70 kVp mode. With ADMIRE, the corresponding values for the 70 kVp mode were 13.7, 12.1 and 1.4 at strength level 2 and 17.6, 15.6 and 1.2 at strength level 4. Mean CTDI{sub vol}, DLP and effective dose were significantly lower with the 70-kVp mode (0.31 mGy, 5.33 mGy*cm, 0.36 mSv) compared to the 80-kVp mode (0.46 mGy, 9.17 mGy*cm, 0.62 mSv; P <.01). The third-generation dual-source CT at 70 kVp provided good objective and subjective image quality at lower radiation exposure. ADMIRE improved objective and subjective image quality. (orig.)

  2. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs; Telangiectasia emorragica ereditaria: TC multidetettore multifasica e programmi di ricostruzione nello studio delle alterazioni vascolari epatiche

    Energy Technology Data Exchange (ETDEWEB)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe [Policlinico Universitario, Bari (Italy). DiMIMP Sezione di Diagnostica per Immagini; Suppressa, Patrizia; Cirulli, Anna; Sabba' , Carlo [Policlinico Universitario, Bari (Italy). Centro Interdipartimentale per lo studio dell' HHT

    2005-02-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT. [Italian] Scopo: Valutare le alterazioni epatiche nei pazienti affetti da Telangiectasia Emorraica Ereditaria (TEE) utilizzando una TC multidetettore (TCMD) ed in nuovi programmi di ricostruzione. Materiale e metodi: E' stato eseguito uno

  3. Experimental study about the effect of different scan parameters and post-processing methods of multi-detector CT on metallic artifacts%多排螺旋 CT 不同扫描参数及图像后处理方式对金属伪影的影响

    Institute of Scientific and Technical Information of China (English)

    储斌; 邹月芬; 王传兵

    2015-01-01

    目的:探讨多排螺旋 CT(MDCT)扫描参数及图像后处理方式对金属植入物伪影的影响,以期获得最佳方案减少金属伪影。方法制作钛合金钢板水模,将其置入 MDCT 下通过调节不同参数进行扫描(包括管电压、管电流、螺距、焦点),然后测定所得图像伪影面积大小并评价其相关性;对常规扫描参数下获得的15例椎体内固定术后患者图像进行后处理,分别使用常规方式和优化方式重建,包括多平面重建(MPR)、调节窗宽窗位及容积再现技术(VRT),然后评价图像质量。结果不同管电压、螺距、焦点下,伪影面积差异有统计学意义,随着管电压升高,伪影面积逐渐减小;随着螺距减小,伪影面积逐渐减小;使用小焦点扫描较大焦点伪影面积小;不同管电流下,伪影面积差异无统计学意义。图像后处理时骨窗重建选择软组织算法(Kernel B40f)、观察时选择窗位600 HU、窗宽2000 HU 及 VRT 三维重建可减少金属伪影。结论选择适当的 MDCT 扫描参数及图像后处理方式可以减少金属伪影,提高图像质量,有助于影像诊断。%Objective To explore the effect of multi-detector computed tomography (MDCT)scan parameters and imaging post-processing methods on metallic artifacts,so as to achieve the perfection in reduction of artifacts caused by metallic implants.Methods Water phantom with titanium alloy steel plate was scanned under MDCT with alternating scan parameters including tube voltage, tube current,pitch and focal spot.The areas of image artifacts were measured and correlated with the scan parameters.Another 1 5 postoperative patients with vertebral implantation scaned with the conventional scan parameters were also included in the study.Ima-ging post-processing including multi-planar reconstruction (MPR),window width and level adjustment,and volume rendering tech-nique (VRT)was performed by using optimized and

  4. Data acquisition for experiments with multi-detector arrays

    Indian Academy of Sciences (India)

    A Chatterjee; Sushil Kamerkar; A K Jethra; S Padmini; M P Diwakar; S S Pande; M D Ghodgaonkar

    2001-07-01

    Experiments with multi-detector arrays have special requirements and place higher demands on computer data acquisition systems. In this contribution we discuss data acquisition systems with special emphasis on multi-detector arrays and in particular we describe a new data acquisition system, AMPS which we have developed recently which is in regular use in experiments at the Pelletron Laboratory, Mumbai. This includes the in-house development of a dedicated crate controller, PC interface card and software.

  5. 多排螺旋CT双动脉期增强扫描对比剂浓度对肝癌检出率的影响%Detection of Hepatocellular Carcinoma with Multi - detector Row CT by Using Double- arterial Phase Enhanced Scanning: Effect of Iodine Concentration of Contrast Material

    Institute of Scientific and Technical Information of China (English)

    周建收; 宦怡; 景建梅

    2011-01-01

    目的:通过多排螺旋CT双动脉期及门脉期增强扫描,以评估对比剂浓度对肝癌检出率的影响.方法:95例肝癌患者随机分为两组行多排螺旋CT肝脏平扫及双动脉期、门脉期增强扫描,其中一组(48例)注射碘帕醇370 mgI/ml( 1.5 ml/kg),另外一组(47例)注射碘帕醇300 mgI/ml (1.85ml/kg),均于30 s注射完毕.扫描后图像由放射科医生阅片并与病理结果进行对比,统计分析两组患者> 2cm及≤2cm的肝癌病灶的诊断敏感性.结果:95例患者中共证实有259个肝癌病灶,其中87个≤2cm,172个>2cm.对于≤2cm的病灶及所有病灶动脉早期及晚期370 mgI/ml组诊断敏感性高于300 mgI/ml组,差别有统计学意义;在门脉期两组患者的诊断敏感性无显著性差异.结论:高浓密度对比剂在动脉早期、晚期可提高肝癌的检出率,特别是对于较小的肝癌病灶(≤2cm).%Purpose: To evaluate the effect of iodine concentration of contrast material on detection of hepatocellular carcinoma (HCC) with multi - detector row CT by using double - arterial phase and portal venous phase enhanced scanning. Methods: Ninety - five patients with HCC were examined by hepatic plain CT and contrast - enhanced CT including early arterial phase(EAP), late arterial phase (LAP) and hepatic parenchymal phase (HPP) scanning prospectively. Patients were randomized into two groups to receive Iopamidol 370 mgl/ml (48 patients, 1.5 ml/kg body weight) and 300 mg I/ml (47 patients, 1.85 ml/ kg body weight) respectively with a fixed injection duration of 30 seconds. The images were interpreted by radiologists and the CT results were compared with the pathological results. The detection sensitivity for tumors of two size categories (=£ 2 cm or > 2 cm) and iodine concentration groups were calculated and analyzed.Results: A total of 259 lesions were detected with 87 less than 2 cm in size and 172 larger than 2cm in size.For EAP and LAP, the sensitivity of Iopamidol 370

  6. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Caro-Dominguez, Pablo; Manson, David E. [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Compton, Gregory [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Department of Medical Imaging, Toronto, ON (Canada); Epworth Hospital, Epworth Medical Imaging, Richmond, VIC (Australia); Humpl, Tilman [University of Toronto, Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON (Canada)

    2016-09-15

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children. (orig.)

  7. Multi-detector Computed Tomography Angiography of the Hepatic Artery in Liver Transplant Recipients

    Energy Technology Data Exchange (ETDEWEB)

    Boraschi, P.; Donati, F.; Cossu, M.C.; Gigoni, R.; Vignali, C.; Filipponi, F.; Bartolozzi, C.; Falaschi, F. [Pisa Univ. Hospital (Italy). 2nd Dept. of Radiology

    2005-08-01

    PURPOSE: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. MATERIAL AND METHODS: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. RESULTS: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. CONCLUSION: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.

  8. Research of Multi Detectors of Neutron Spectrum in Mix Fields

    Institute of Scientific and Technical Information of China (English)

    LI; Wei; CHEN; Jun; WANG; Zhi-qiang; LI; Chun-juan; LIU; Yi-na; LUO; Hai-long; ZHANG; Wei-hua

    2013-01-01

    This neutron spectrometer can be used to measure neutron spectrum and neutron equivalent dosimetry.The range of neutron spectrum is thermal-20 MeV,and the range of neutron equivalent dosimetry is 1μSv·h-1-4 mSv·h-1.The sensor head of the neutron spectrum of multi detectors in mix fields houses five gas-filled sensors and a photo-scintillator column.There are two boron tri-fluoride(BF3)and three hydrogen

  9. Endovascular treatment of thoracic aortic diseases: Follow-up and complications with multi-detector computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)], E-mail: r.iezzi@rad.unich.it; Cotroneo, Antonio Raffaele; Marano, Riccardo; Filippone, Antonella; Storto, Maria Luigia [Department of Radiology, University ' G. D' Annunzio' , Chieti (Italy)

    2008-03-15

    Endovascular procedures with placement of stent-graft has become an accepted alternative to traditional open surgery for treatment of descending thoracic aortic aneurysms, ulcers, post-traumatic rupture, or complications of type-B dissection, due to significant reduction in perioperative mortality, rate of complications and length of hospitalization. Moreover, increasing operator experience and continuous advances in stent-graft technology are making treatment of a wider range of cases possible with redefinition of guidelines for endovascular stent-graft. The feasibility of endovascular stent-graft is mainly dependent on anatomic factors which represent the important predictors of the success of this procedure as well as on strictly follow-up in order to obtain early detection and treatment of eventual complications. Multi-detector CT-angiography is a fast, safe, and minimally invasive imaging technique that represents the standard of reference in the follow-up of patients who have undergone endovascular stent-graft, as it is effective and specific in the detection of procedure-correlated complications. The purpose of this article is to give a brief review of those techniques most commonly used for endovascular treatment of thoracic aortic diseases together with a more detailed description of post-procedural complications and their appearance on multi-detector CT-angiography.

  10. 64排128层螺旋CT图像重建技术对胆脂瘤型中耳炎的术前评估价值%The Value of Preoperative Assessment about Otitis Media with Cholesteatoma by Image Reconstruction of 64-Multidetector 128-Slice Computer Tomography

    Institute of Scientific and Technical Information of China (English)

    相丽; 郑穗生

    2011-01-01

    Obiective To explore the advantages and disadvantages of post-processing techniques of MSCT to the manifestation of bone destruction in ears with otitis media with cholesteatoma. Materials and Methods fmage reconstruction of 64-multidetector 128-slice CT were performed to middle and internal ears of 42 ears with otitis media with cholesteatoma in different ways. The images were compared to intraoperative findings, and the concordance of the two underwent Kappa test. SPSS was used to deal with the results. High concordance was defined as Kappa ≥0.75. Acceptable concordance was defined as 0. 41/Ukappa"00.75. Low concordance was defined as Kappa"U0.4. Results Kappa values of head of malleus, long crus of incus, short crus of incus, body of incus body, bone destruction of meningeal board, aditus ad antrum expanding and structure defects of horizontal segment of facial nerve canal were greater than 0.75L?Kappa values of handle of malleus, incudomelleolar joints, horizontal and labyrinthin segment of facial nerve canal, semicircular canal, scutum, bone wall of sigmoid sinus and bone destruction of labyrinth were between 0.4 and 0.75, but Kappa values of incudostapedial joint, anterior crus of stapes, posterior crus of stapes and bone destruction of footplate of stapes were less than 0.4. Conclusions Images of bone destruction in middle and internal ears with otitis media with cholesteatoma have important reference value for the operation.%目的 探讨MSCT后处理技术对胆脂瘤型中耳炎骨质破坏情况显示的优劣势.材料与方法 采用64排128层螺旋CT对42耳胆脂瘤型中耳炎中耳及内耳结构进行多种方式重建,结果与术中所见对照,Kappa检验二者的一致性,采用SPSS11.0软件包处理,规定 Kappa值大于或等于0.75为两者有很高的一致程度,其值在0.4-0.75说明一致程度尚可.小于0.4则说明一致程度不够理想.结果 锤骨头、砧骨长脚、砧骨短脚、砧骨体、脑膜板骨壁骨质破坏

  11. Toroid cavity/coil NMR multi-detector

    Science.gov (United States)

    Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.

    2007-09-18

    An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.

  12. Enhanced security for multi-detector quantum random number generators

    Science.gov (United States)

    Marangon, Davide G.; Vallone, Giuseppe; Zanforlin, Ugo; Villoresi, Paolo

    2016-11-01

    Quantum random number generators (QRNG) represent an advanced solution for randomness generation, which is essential in every cryptographic application. In this context, integrated arrays of single-photon detectors have promising applications as QRNGs based on the spatial detection of photons. For the employment of QRNGs in cryptography, it is necessary to have efficient methods to evaluate the so-called quantum min-entropy that corresponds to the amount of the true extractable quantum randomness from the QRNG. Here, we present an efficient method that allows the estimation of the quantum min-entropy for a multi-detector QRNG. In particular, we consider a scenario in which an attacker can control the efficiency of the detectors and knows the emitted number of photons. Eventually, we apply the method to a QRNG with 103 detectors.

  13. Multi-dimensional visualization of coronary aberrancies using multi detector computed tomography

    NARCIS (Netherlands)

    van Ooijen, P; Dorgelo, J; Tukker, W; Willemsen, H; Oudkerk, M; Lewis, BS; Halon, DA; Flugelman, MY; Gensini, GF

    2003-01-01

    The purpose of this study was to evaluate the usefulness of three and four dimensional visualization of multi detector computed tomography datasets for the evaluation of coronary aberrancies. Multi detector computed tomography (MDCT) datasets were obtained in thirteen patients following a standard p

  14. Imaging features of solid pseudopapillary tumor of the pancreas on multi-detector row computed tomography

    Institute of Scientific and Technical Information of China (English)

    Deng-Bin Wang; Qing-Bing Wang; Wei-Min Chai; Ke-Min Chen; Xia-Xing Deng

    2009-01-01

    AIM:To retrospectively analyze the imaging features of solid-pseudopapillary tumors (SPTs) of the pancreas on multi-detector row computed tomography (MDCT) and define the imaging findings suggestive of malignant potential.METHODS: A total of 24 consecutive cases with surgically and pathologically confirmed SPTs of the pancreas underwent preoperative abdominal MDCT studies in our hospital. All axial CT images, CT angiographic images, and coronally and sagittally reformed images were obtained. The images were retrospectively reviewed at interactive picture archiving and communication system workstations. RESULTS: Of the 24 cases of SPTs, 11 cases (45.8%) occurred in the pancreatic head and seven (29.1%) in the tail. Eighteen were pathologically diagnosed as benign and six as malignant. MDCT diagnosis of SPTs was well correlated with the surgical and pathological results (Kappa = 0.6, P < 0.05). The size of SPTs ranged from 3 to 15 cm (mean, 5.8 cm). When the size of the tumor was greater than 6 cm (including 6cm), the possibilities of vascular (8 vs 1) and capsular invasion (9 vs 0) increased significantly ( P < 0.05). Two pathologically benign cases with vascular invasion and disrupted capsule on MDCT presented with local recurrence and hepatic metastases during follow-up about 1 year after the resection of the primary tumors.CONCLUSION: Vascular and capsular invasion with superimposed spread into the adjacent pancreatic parenchyma and nearby structures in SPTs of the pancreas can be accurately revealed by MDCTpreoperatively. These imaging findings are predictive of the malignant potential associated with the aggressive behavior of the tumor, even in the pathologically benign cases.

  15. Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.D.; Koesling, S. [University of Halle-Wittenberg, Department of Radiology, Halle Saale (Germany); Mlynski, R. [Head and Neck Surgery ' ' Otto Koerner' ' , Department of Otorhinolaryngology, Rostock (Germany); Plontke, S.K. [University of Halle-Wittenberg, Department of Otorhinolaryngology, Head and Neck Surgery, Halle Saale (Germany)

    2016-12-15

    Modern passive middle ear titanium prostheses are filigree structures, resulting in poorer depiction on CT compared to prostheses used in the past. We compared the visibility of newer prostheses on cone beam CT (CBCT) to multi-detector CT (MDCT) with standard and lower dose in vitro, and analysed image noise and metal artefacts. Six different titanium middle ear prostheses (three partial and one total ossicular replacement prostheses, two stapes prostheses) were implanted twice in formalin-fixed head specimens - first correctly and then with displacement. Imaging was performed using standard CBCT and MDCT as well as MDCT with lower dose (36 single imaging investigations). Images were analysed with knowledge of the used types of middle ear prostheses, but blinded with respect to the positioning in the specific case. On all images the type of prostheses and their positions could be clearly recognized. Their identifiability including their details was rated as statistically significantly higher for all CBCT investigations than for MDCT. MDCT with lower dose showed the worst results. No statistical differences were found in image noise and metal artefacts. If available, CBCT should be preferred over MDCT in diagnostic evaluation of passive middle ear prostheses. (orig.)

  16. Scoliotic Change in Patients Having Undergone a Mastectomy: Analysis Using Multi-Detector Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moo Sang; Kim, Hye Won; Juhng, Seon Kwan; Choi, Si Sung [Dept. of Radiology, Wankwang University School of Medicine, Iksan (Korea, Republic of)

    2011-09-15

    To evaluate the relationship between the degree of scoliotic curvature and postoperative change of the chest wall among patients who underwent a unilateral mastectomy. Subjects were comprised of 56 women who underwent chest CT and a whole spine standing anteroposterior view (WSSAP). Cobb's angle and each side of the chest wall volume, including the breast, were measured with the WSSAP and a 3-D reconstructed multi-detector computed tomography (MDCT) image. A correlation analysis was performed between the scoliotic curvature and chest wall volume asymmetry. Directional correspondence between development of scoliosis and undergoing a mastectomy was analyzed. Furthermore, a survey on patient shoulder function was performed using a questionnaire and a correlation was performed between the results of the survey and the scoliotic curvature and chest wall volume asymmetry. The findings indicate that Cobb's angles were 4.4 degree {+-} 2.7 (Mean {+-} SD, range from 0.6 to 11.4). Differences in chest wall volume were 474.64 {+-} 276.36 cm{sup 3} (Mean {+-} SD, range from 78 to 1379). No statistical significance was noted between the degree of scoliotic curvature and chest wall volume asymmetry (p > 0.05). A cross-tabulation analysis of the direction between the scoliotic curvature and mastectomy was found to be statistically significant (p < 0.001). Also, there was a significant correlation between shoulder function assessment score and the degree of scoliotic curvature (p = 0.003), while no significant correlation between shoulder function assessment score and chest wall volume asymmetry (p 0.091) could be found. Scoliotic change had a tendency to be on the opposite side of the mastectomy and had no statistically significant relationship with the volume asymmetry. Thus, 3-D reconstructed MDCT images are helpful in differentiating selective volume differences.

  17. Sixty-four-multi-detector computed tomography diagnosis of coronary artery anomalies in 66 patients

    Institute of Scientific and Technical Information of China (English)

    YANG Shan; ZENG Meng-su; ZHANG Zhi-yong; LING Zhi-qing; MA Jian-ying; CHEN Gang

    2010-01-01

    Background The abnormalities of coronary arteries, though rare and sometimes benign, may first present clinically as myocardial infarction or sudden death. Multi-detector computed tomography (MDCT) is a non-invasive test that is highly suitable for detecting these anomalies. The study aimed to review the 64-MDCT appearance of the coronary artery anomalies in 66 patients and to discuss the clinical importance of these anomalies.Methods In 6014 consecutive patients examined over 12 months by 64-MDCT for the study of coronary artery disease, 66 were diagnosed for coronary artery anomalies. All patients were symptomatic for one or more of the following diseases: chest pain, dyspnoea, palpitations, arrhythmia and myocardial infarction. Nine patients had undergone a coronary angiography. All the CT images were evaluated by two radiologists and one cardiologist. The right coronary artery (RCA) and the conus branch arising separately, myocardial bridging and duplication of arteries were not analysed in our study.Results The incidence of coronary artery anomalies found in our study group was 1.097%. In the selected patients, seven different types of coronary anomalies were found by 64-MDCT examination. The high takeoff, origin of the coronary artery from the opposite or noncoronary sinus with an anomalous course, and coronary artery fistula were the three common forms of anomalies (n=16, 18 and 16, respectively). Compared with the results of the coronary angiography, the number of the drainage sites of two coronary artery fistula was less in MDCT images (3 small sites in total). In all cases, coronary artery computed tomography angiography (CTA) technique was able to recognize the origin of the coronary artery, its three-dimensional course and its spatial relationship with the adjacent structures. Conventional coronary angiography in two cases, however, was unable to provide sufficient information for correct and complete diagnosis.Conclusions In conclusion, the study

  18. Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, Anna; Gordic, Sonja; Lauk, Eliane; Frauenfelder, Thomas; Alkadhi, Hatem; Husarik, Daniela B. [University Hospital Zurich, Institute for Diagnostic and Interventional Radiology, Zurich (Switzerland); Leschka, Sebastian [University Hospital Zurich, Institute for Diagnostic and Interventional Radiology, Zurich (Switzerland); Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland)

    2015-08-15

    To assess radiation dose and image quality in body CT-angiography (CTA) with automated attenuation-based tube voltage selection (ATVS) on a 192-slice dual-source CT (DSCT). Forty patients (69.5 ± 9.6 years) who had undergone body CTA with ATVS (ref.kVp 100, ref.mAs 90) using a 2x192-slice CT in single-source mode were retrospectively included. All patients had undergone prior CTA with a 2x128-slice CT and ATVS with identical imaging and contrast media protocols, serving for comparison. Images were reconstructed with iterative reconstruction at similar strength levels. Radiation dose was determined. Image quality was assessed semi-quantitatively (1:excellent, 5:non-diagnostic), aortic attenuation, noise and CNR were determined. As compared to 128-slice DSCT, 192-slice DSCT selected tube voltages were lower in 30 patients (75 %), higher in 3 (7.5 %), and similar in 7 patients (17.5 %). CTDI{sub vol} was lower with 192-slice DSCT (4.7 ± 1.9 mGy vs. 5.8 ± 2.1 mGy; p < 0.001). Subjective image quality, mean aortic attenuation (342 ± 67HU vs. 268 ± 67HU) and CNR (9.8 ± 2.5 vs. 8.2 ± 2.9) were higher with 192-slice DSCT (all p < 0.01), all datasets being diagnostic. Our study suggests that ATVS of 192-slice DSCT for body CTA is associated with an improved image quality and further radiation dose reduction of 19 % compared to 128-slice DSCT. (orig.)

  19. Multi-detector CT and 3D imaging in a multi-vendor PACS environment

    NARCIS (Netherlands)

    van Ooijen, PMA; Witkamp, R; Oudkerk, M; Lemke, HU; Inamura, K; Doi, K; Vannier, MW; Farman, AG; Reiber, JHC

    2003-01-01

    Introduction of new hard- and software techniques like Multi-Dectector Computed Tomography (MDCT) and 3D imaging has put new demands on the Picture Archiving and Communications System (PACS) environment within the radiology department. The daily use of these new techniques requires a good integratio

  20. Bent Si monochromator—multi-detector neutron diffractometer installed at B4 super-mirror thermal guide tube in KUR

    Science.gov (United States)

    Achiwa, N.; Kawano, S.; Hino, M.; Mikula, P.; Ono, M.; Fukunaga, T.

    2004-08-01

    A new multi-detector neutron diffractometer has been installed at B4 thermal supermirror neutron guide in KUR, using a new bent Si monochromator developed by Mikula et al. and Ono et al.. Here we report resolutions of powder diffraction patterns by the multi-detector neutron diffractometer, which mainly depend on a radius of sample. Bragg diffraction optics by bent perfect crystal shows improvement of resolution without loss of luminosity and the multi- detector on the same 2 θ arm can gain the intensity without loosing resolution.

  1. Predictive value of multi-detector computed tomography for accurate diagnosis of serous cystadenoma: Radiologic-pathologic correlation

    Institute of Scientific and Technical Information of China (English)

    Anjuli A Shah; Nisha I Sainani; Avinash Kambadakone Ramesh; Zarine K Shah; Vikram Deshpande; Peter F Hahn; Dushyant V Sahani

    2009-01-01

    AIM:To identify multi-detector computed tomography (MDCT) features mos t predi c t i ve of serous cystadenomas (SCAs),correlating with histopathology,and to study the impact of cyst size and MDCT technique on reader performance.METHODS:The MDCT scans of 164 patients with surgically verified pancreatic cystic lesions were reviewed by two readers to study the predictive value of various morphological features for establishing a diagnosis of SCAs.Accuracy in lesion characterization and reader confidence were correlated with lesion size (≤3 cm or ≥3 cm) and scanning protocols (dedicated vs routine).RESULTS:28/164 cysts (mean size,39 mm;range,8-92 mm) were diagnosed as SCA on pathology.The MDCT features predictive of diagnosis of SCA were microcystic appearance (22/28,78.6%),surface lobulations (25/28,89.3%) and central scar (9/28,32.4%).Stepwise logistic regression analysis showed that only microcystic appearance was significant for CT diagnosis of SCA (P=0.0001).The sensitivity,specificity and PPV of central scar and of combined microcystic appearance and lobulations were 32.4%/100%/100% and 68%/100%/100%,respectively.The reader confidence was higher for lesions>3 cm (P=0.02) and for MDCT scans performed using thin collimation (1.25-2.5 mm) compared to routine 5 mm collimation exams (P>0.05).CONCLUSION:Central scar on MDCT is diagnostic of SCA but is seen in only one third of SCAs.Microcystic morphology is the most significant CT feature in diagnosis of SCA.A combination of microcystic appearance and surface lobulations offers accuracy comparable to central scar with higher sensitivity.

  2. Study of statistical properties of hybrid statistic in coherent multi-detector CBC Search

    CERN Document Server

    Haris, K

    2015-01-01

    In this article, we revisit the problem of coherent multi-detector search of gravitational wave from compact binary coalescence with Neutron stars and Black Holes using advanced interferometers like LIGO-Virgo. Based on the loss of optimal multi-detector signal-to-noise ratio (SNR), we construct a hybrid statistic as a best of maximum-likelihood-ratio(MLR) statistic tuned for face-on and face-off binaries. The statistical properties of the hybrid statistic is studied. The performance of this hybrid statistic is compared with that of the coherent MLR statistic for generic inclination angles. Owing to the single synthetic data stream, the hybrid statistic gives low false alarms compared to the multi-detector MLR statistic and small fractional loss in the optimum SNR for a large range of binary inclinations. We have demonstrated that for a LIGO-Virgo network and binary inclination, \\epsilon 110 deg., the hybrid statistic captures more than 98% of network optimum matched filter SNR with low false alarm rate. The...

  3. Cardiac pathologies incidentally detected with non-gated chest CT; Inzidentelle Pathologien des Herzens im Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Axel; Kroepil, P.; Lanzman, R.S.; Moedder, U. [Inst. fuer Radiologie, Universitaetsklinikum Duesseldorf, Heinrich-Heine-Univ. (Germany); Choy, G.; Abbara, S. [Cardiovascular Imaging Section, Massachusetts General Hospital, Harvard Medical School (United States)

    2009-12-15

    Cardiac imaging using electrocardiogram-gated multi-detector computed tomography (MDCT) permits noninvasive diagnosis of congenital and acquired cardiac pathologies and has thus become increasingly important in the last years. Several studies investigated the incidence and relevance of incidental extracardiac structures within the lungs, mediastinum, chest wall, and abdomen with gated coronary CT. This resulted in the general acceptance of the review of extracardiac structures as a routine component of coronary CT interpretation. On the other hand radiologists tend to neglect pericardial and cardiac pathologies in non-gated chest CT, which is primarily performed for the evaluation of the respiratory system or for tumor staging. Since the introduction of multi-detector spiral CT technology, the incidental detection of cardiac and pericardial findings has become possible using non-gated chest CT. This article reviews the imaging appearances and differential diagnostic considerations of incidental cardiac entities that may be encountered in non-gated chest CT. (orig.)

  4. The utility of multi-detector computed tomography in the diagnosis of malignant pleural effusion in the patients with ovarian cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Won [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Choi, Hyuck Jae, E-mail: hjchoi@ncc.re.k [Department of Radiology, Asan Medical Center, University of Ulsan, Seoul (Korea, Republic of); Kang, Sokbom; Park, Sang-Yoon; Jung, Dae Chul [Research Institute and Hospital, National Cancer Center (Korea, Republic of); Cho, Jeong Yeon [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Kyung-Sik [Department of Radiology, Asan Medical Center, University of Ulsan, Seoul (Korea, Republic of); Kim, Seung Hyup [Department of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    Purpose: The purpose of this study was to retrospectively assess possible clinical predictors of malignant pleural effusion in patients with ovarian cancer. Materials and methods: This review was performed on 38 ovarian cancer patients that showed pleural effusion in a CT scan and who underwent thoracocentesis before treatment. CT scans were obtained using a 4-channel multi-detector CT scanner. Fisher's exact test was used to determine the probability of malignant pleural effusion as a function of; amount of ascites, lymph node enlargement, amount of pleural effusion, pleural nodules, and pleural thickening. Results: Sixteen (42.1%) of the 38 patients had malignant pleural effusion and malignant pleural effusion amounts were greater than those with nonmalignant effusion. Pleural nodules were more frequently found in the malignant pleural effusion group (eight [50%] patients) than in the nonmalignant group (zero [0%] patient) (p < 0.001). Supradiaphragmatic lymph node enlargement (with short axis diameter 1 cm or more) was more frequent in malignant group (12 [75%] patients) than in the nonmalignant group (two [9.1%] patients) (p < 0.001). Conclusion: The probability of malignant pleural effusion in patients with ovarian cancer was found to be correlated with the amount of pleural effusion, the presence of pleural nodules, and supradiaphragmatic lymph node enlargement.

  5. Diagnostic performance of using effervescent powder for detection and grading of esophageal varices by multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cansu, Aysegul, E-mail: drcansu@gmail.com [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Ahmetoglu, Ali; Kul, Sibel; Yukunc, Gokcen [Department of Radiology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Fidan, Sami; Arslan, Mehmet [Department of Gastroenterology, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey); Topbas, Murat [Department of Public Health, Karadeniz Technical University School of Medicine, Farabi Hospital, 61080 Trabzon (Turkey)

    2014-03-15

    Purpose: To investigate the effect of using effervescent powder (EP) on the efficacy of multi-detector computed tomography (MDCT) in detection and grading of esophageal varices in cirrhotic patients by considering endoscopy as the gold standard. Materials and methods: Ninety-two cirrhotic patients undergoing biphasic liver MDCT followed by upper gastrointestinal endoscopy within 4 weeks of MDCT were prospectively evaluated. The patients were divided into two groups before MDCT. The first group (n = 50) received effervescent powder (EP) before and during MDCT procedure and the second group did not receive (n = 42). The presence, size and grade of the esophageal varices were evaluated. MDCT findings were compared with endoscopic results. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of MDCT with EP and without EP were calculated and compared. Correlations between the grades of the varices for each group based on MDCT imaging and endoscopic grading were also evaluated. Results: The sensitivity, specificity, accuracy, PPV, and NPV of MDCT were 100%, 88%, 96%, 94%, and 100%, respectively, in the EP group, whereas they were 76%, 67%, 74%, 89%, and 43%, respectively, in the non-EP group. Correlations between the grades of the esophageal varices on MDCT and endoscopy were significant in both groups (r = 0.94, p < 0.001 for EP group and r = 0.70, p < 0.001 for non-EP group). Conclusion: During periodic CT scanning of cirrhotic patients, use of EP increases the success rate of MDCT for detection and grading of esophageal varices.

  6. Imaging features of intraductal papillary mucinous neoplasms of the pancreas in multi-detector row computed tomography

    Institute of Scientific and Technical Information of China (English)

    Ling Tan; Ya-E Zhao; Deng-Bin Wang; Qing-Bing Wang; Jing Hu; Ke-Min Chen; Xia-Xing Deng

    2009-01-01

    AIM:To retrospectively evaluate the imaging features of pancreatic intraductal papillary mucinous neoplasms (IPMNs) in multi-detector row computed tomography (MDCT).METHODS:A total of 20 patients with pathologicallyconfirmed intraductal papillary mucinous neoplasms (IPMNs) were included in this study.Axial MDCT images combined with CT angiography (CTA) and multiplanar volume reformations (MPVR) or curved reformations (CR) were preoperatively acquired.Two radiologists (Tan L and Wang DB) reviewed all the images in consensus using an interactive picture archiving and communication system.The disputes in readings were resolved through consultation with a third experienced radiologist (Chen KM).Finally,the findings and diagnoses were compared with the pathologic results.RESULTS:The pathological study revealed 12 malignant IPMNs and eight benign IPMNs.The diameters of the cystic lesions and main pancreatic ducts (MPDs) were significantly larger in malignant IPMNs compared with those of the benign IPMNs (P<0.05).The combinedtype IPMNs had a higher rate of malignancy than the other two types of IPMNs (P<0.05).Tumors with mural nodules and thick septa had a significantly higher incidence of malignancy than tumors without these features (P<0.05).Communication of side-branch IPMNs with the MPD was present in nine cases at pathologic examination.Seven of them were identified from CTA and MPVR or CR images.From comparison with the pathological diagnosis,the sensitivity,specificity,and accuracy of MDCT in characterizing the malignancy of IPMN of the pancreas were determined to be 100%,87.5% and 95%,respectively.CONCLUSION:MDCT with CTA and MPVR or CR techniques can elucidate the imaging features of IPMNs and help predict the malignancy of these tumors.

  7. Double Chooz: optimizing the sensitivity to {theta}{sub 13} with a multi-detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Novella, P. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain)

    2012-08-15

    The best upper limit to the neutrino mixing angle {theta}{sub 13} is set by the CHOOZ experiment. The eventual measurement of {theta}{sub 13} in reactor neutrino experiments relies on a reduction of the CHOOZ systematics of about 1 order of magnitude, along with a major increase of the luminosity. Provided that enough statistics are achieved, fighting the systematics becomes the key towards {theta}{sub 13}. The Double Chooz experiment engages this fight with a multi-detector set up.

  8. Control electronics for a multi-laser/multi-detector scanning system

    Science.gov (United States)

    Kennedy, W.

    1980-01-01

    The Mars Rover Laser Scanning system uses a precision laser pointing mechanism, a photodetector array, and the concept of triangulation to perform three dimensional scene analysis. The system is used for real time terrain sensing and vision. The Multi-Laser/Multi-Detector laser scanning system is controlled by a digital device called the ML/MD controller. A next generation laser scanning system, based on the Level 2 controller, is microprocessor based. The new controller capabilities far exceed those of the ML/MD device. The first draft circuit details and general software structure are presented.

  9. Multi-detector computed tomography imaging of large airway pathology:A pictorial review

    Institute of Scientific and Technical Information of China (English)

    Tejeshwar Singh Jugpal; Anju Garg; Gulshan Rai Sethi; Mradul Kumar Daga; Jyoti Kumar

    2015-01-01

    The tracheobronchial tree is a musculo-cartilagenous framework which acts as a conduit to aerate the lungs and consequently the entire body. A large spectrum of pathological conditions can involve the trachea and bronchial airways. These may be congenital anomalies, infections, post-intubation airway injuries, foreign body aspiration or neoplasms involving the airway. Appropriate management of airway disease requires an early and accurate diagnosis. In this pictorial essay review, we will comprehensively describe the various airway pathologies and their imaging findings by multi-detector computed tomography.

  10. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography.

    Science.gov (United States)

    Shergill, Arvind K; Maraj, Tishan; Barszczyk, Mark S; Cheung, Helen; Singh, Navneet; Zavodni, Anna E

    2015-01-01

    Blunt and penetrating cardiovascular (CV) injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT) has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center.

  11. Identification of Cardiac and Aortic Injuries in Trauma with Multi-detector Computed Tomography

    Directory of Open Access Journals (Sweden)

    Arvind K Shergill

    2015-01-01

    Full Text Available Blunt and penetrating cardiovascular (CV injuries are associated with a high morbidity and mortality. Rapid detection of these injuries in trauma is critical for patient survival. The advent of multi-detector computed tomography (MDCT has led to increased detection of CV injuries during rapid comprehensive scanning of stabilized major trauma patients. MDCT has the ability to acquire images with a higher temporal and spatial resolution, as well as the capability to create multiplanar reformats. This pictorial review illustrates several common and life-threatening traumatic CV injuries from a regional trauma center.

  12. Novel wearable and wireless ring-type pulse oximeter with multi-detectors.

    Science.gov (United States)

    Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh

    2014-01-01

    The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  13. Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors

    Directory of Open Access Journals (Sweden)

    Cheng-Yang Huang

    2014-09-01

    Full Text Available The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2. Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.

  14. Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Rixe, Johannes; Schmitt, Joern; Neumann, Thomas; Hamm, Christian W.; Rolf, Andreas [Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany); University Hospital of Giessen and Marburg, Site Giessen, Department of Internal Medicine I (Cardiology, Angiology), Giessen (Germany); Schuhbaeck, Annika; Nef, Holger M.; Achenbach, Stephan [University Hospital of Giessen and Marburg, Site Giessen, Department of Internal Medicine I (Cardiology, Angiology), Giessen (Germany); Liebetrau, Christoph; Moellmann, Helge; Szardien, Sebastian; Brandt, Roland [Kerckhoff Heart and Thorax Center, Department of Cardiology, Bad Nauheim (Germany); Schneider, Christian; Krombach, Gabriele [University Hospital of Giessen and Marburg, Department of Radiology, Giessen (Germany)

    2012-12-15

    In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI. A total of 122 patients (67 male, mean age 84 {+-} 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated. Mean eccentricity of the aortic annulus determined by MDCT was 0.34 {+-} 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 {+-} 2.1 mm in MDCT and 24.0 {+-} 2.5 mm in TEE (P < 0.0001 for agreement). Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. (orig.)

  15. Performance comparison of multi-detector detection statistics in targeted compact binary coalescence GW search

    CERN Document Server

    Haris, K

    2016-01-01

    Global network of advanced Interferometric gravitational wave (GW) detectors are expected to be on-line soon. Coherent observation of GW from a distant compact binary coalescence (CBC) with a network of interferometers located in different continents give crucial information about the source such as source location and polarization information. In this paper we compare different multi-detector network detection statistics for CBC search. In maximum likelihood ratio (MLR) based detection approaches, the likelihood ratio is optimized to obtain the best model parameters and the best likelihood ratio value is used as statistic to make decision on the presence of signal. However, an alternative Bayesian approach involves marginalization of the likelihood ratio over the parameters to obtain the average likelihood ratio. We obtain an analytical expression for the Bayesian statistic using the two effective synthetic data streams for targeted search of non-spinning compact binary systems with an uninformative prior on...

  16. Reducing radiation in CT urography for hematuria: Effect of using 100 kilovoltage protocol

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sungwon, E-mail: sungwonlee8@gmail.com [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-701 (Korea, Republic of); Jung, Seung Eun, E-mail: sejung@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-701 (Korea, Republic of); Rha, Sung Eun, E-mail: serha@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-701 (Korea, Republic of); Byun, Jae Young, E-mail: jybyun@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-701 (Korea, Republic of)

    2012-08-15

    Objective: To compare 128-slice multidetector computed tomography (MDCT) at 100 kVp and 120 kVp for image quality and radiation dose. Materials and methods: Our study had approval of our institutional review board. We retrospectively selected 25 patients who underwent CT urography for the evaluation of hematuria. The CT scans were taken with 128-slice MDCT, with three phases (precontrast, nephrographic, and excretory), using an automatic tube current modulation with reference tube level of 180 mA s and tube voltages of either 100 kVp (n = 14, mean age 26.71) or 120 kVp (n = 11, mean age 25.54). The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) of the urinary tract, the subjective image quality of the urinary tract evaluated with a five point scale by two radiologists and the effective dose calculated on the basis of dose-length-product (DLP) and volume-CT-dose-index (CTDIvol) were compared between the groups with Student's t test or Mann-Whitney U test. Results: There was no significant difference in the SNR (p = 0.358), CNR (p = 0.303) and the subjective image quality (p = 0.486) between the two protocols. The mean CTDIvol, DLP and the effective dose in the 100 kVp protocol were significantly lower than the 120 kVp protocol (p = 0.000, 0.000). Conclusion: CT urography using 100 kVp protocol resulted in reduction of radiation dose without loss of objective or subjective image quality.

  17. Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art

    OpenAIRE

    Stradiotti, P.; Curti, A.; G. Castellazzi; Zerbi, A.

    2009-01-01

    The projectional nature of radiogram limits its amount of information about the instrumented spine. MRI and CT imaging can be more helpful, using cross-sectional view. However, the presence of metal-related artifacts at both conventional CT and MRI imaging can obscure relevant anatomy and disease. We reviewed the literature about overcoming artifacts from metallic orthopaedic implants at high-field strength MRI imaging and multi-detector CT. The evolution of multichannel CT has made available...

  18. Recurrence of Takotsubo Cardiomyopathy: Role of Multi- Detector Computed Tomography Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Yaser Jenab

    2015-10-01

    Full Text Available Takotsubo cardiomyopathy (TCM, also known as stress-induced cardiomyopathy, is a clinical syndrome of transient left ventricular (LV apical wall motion abnormality with relative preservation of the basal heart segments in the absence of any significant atherosclerosis. Recurrence of this condition is rare. We report a postmenopausal woman, who experienced two episodes of TCM within 4 months following emotional and physical stress. In the first episode, she was admitted due to severe dyspnea, accompanied by sudden-onset, prolonged, burning chest pain and palpitation. Transthoracic echocardiography revealed akinesia of the LV, with the exception of the basal regions. Coronary angiography demonstrated no significant coronary artery disease, and follow-up echocardiography showed normalization of the LV wall motion abnormalities. In the second episode, she experienced similar symptoms and echocardiography revealed similar changes. Multi-detector computed tomography revealed normal coronary arteries. After 9 days, she was discharged in good condition; and at 3 months’ follow- up, she was symptom-free with normal echocardiography.

  19. Synthetic streams in a Gravitational Wave inspiral search with a multi-detector network

    CERN Document Server

    K, Haris

    2014-01-01

    Gravitational Wave Inspiral search with a global network of interferometers when carried in a phase coherent fashion would mimic an effective multi-detector network with synthetic streams constructed by the linear combination of the data from different detectors. For the first time, we demonstrate that the two synthetic data streams pertaining to the two polarizations of Gravitational Wave can be derived prior to the maximum-likelihood analysis in a most natural way using the technique of singular-value-decomposition applied to the network signal-to-noise ratio vector. We construct the network matched filters in combined network plus spectral space which capture both the synthetic streams. We further show that the network LLR is then sum of the LLR of each synthetic stream. The four extrinsic parameters are mapped to the two amplitudes and two phases. The maximization over these is a straightforward approach closely linked to the single detector approach. Towards the end, we connect all the previous works rel...

  20. Prediction of short term outcome of pulmonary embolism: Parameters at 16 multi-detector CT pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Mohamed Mohamed Hefeda

    2014-12-01

    Results: Thirty-two patients were included in the study, 23 (71.8% of them were classified as survivors, and the other nine (28.1% patients died within the first month (non survivors. There was a positive, but weak correlation between the Qanadli score and the short term mortality (P value = 0.05. There was a statistically significant relationship between the RV/LV ratio and PE-related mortality, with a P value 18 according to the Qanadli score and to a lesser degree the interventricular septum abnormality.

  1. Use of multi-detector CT angiography in identification and classification of aorto-iliac diseases; clinical and surgical application

    Directory of Open Access Journals (Sweden)

    Reda Abdelsamie Alarabawy

    2016-03-01

    Conclusions: MDCT angiography is excellent noninvasive scanning technique for patients suspected of having aorto-iliac occlusive disease, with higher spatial resolution and faster acquisition times, allowing assessment of the aorta and its branches with greater accuracy than other modalities.

  2. MULTI - DETECTOR COMPUTED TOMOGRAPHY AND INTRA - OPERATIVE CORRELATION IN BLUNT ABDOMINAL TRAUMA

    Directory of Open Access Journals (Sweden)

    Rakesh

    2014-01-01

    Full Text Available BACKGROUND : With the change in the pace of life fast , faster , fastest being the motto of the present day , the incidence of trauma and the associated mortality and morbidities is on a continuous rise.Imaging plays a very important role in the management of these injuries in deciding which injuries , in trauma the final verdict of organ injury in abdomen is intra - ope rative findings. AIMS : In view of the above said we considered to study to determine diagnostic accuracy of MDCT (Multi - Detector Computed Tomography in detection of intra - abdominal solid organ injury in blunt abdominal trauma and to highlight the importance of MDCT in evaluation of blunt abdominal trauma. METHODS AND MATERIALS : This was a prospective study done between over a period of 2 years from between January 2011 to February 2013 on patients who presented with blun t abdominal trauma after excluding patients who were managed conservatively and normal on imaging , the data we compared had 32 patients and the analysis was as follows. RESULTS : Blunt abdominal trauma was common in males , the male to female ratio was 9:1 , road traffic accident is the most common mode of injury in blunt abdominal trauma with 60% of the patients in this mode of injury , single organ injury is 22 patients (76% spleen is the most commonly injured organ 15(47% patients having splenic injury , wi th grade 3 being the commonest splenic injury 8 out of the 15 patients had splenic injury bowel injury was the second common organ injured in blunt trauma abdomen. In this study computed tomography grading correlated well with intra - operative grading with a PPV of= 95.45 % (95% ci: 84.50 % to 99.31 % Asensitivityof 76.36 % (95% ci: 62.98 % to 86.76 % . CONCLUSION : Computed tomography is an important imaging technique for diagnosis of organ injuries in patients with abdominal trauma. It helps in grading of the type of injury and accordingly deciding the management of patient. It is a highly

  3. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  4. Ascending aorta measurements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish normative values for transcatheter therapies

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Tri-Linh C.; Rizzo, Elena [University Hospital Lausanne (CHUV), Department of Radiology, Lausanne (Switzerland); Huber, Christoph H.; Segesser, Ludwig K. von [University Hospital Lausanne (CHUV), Department of Cardiovascular Surgery, Lausanne (Switzerland); Dehmeshki, Jashmid [Kingston University, Digital Imaging Research Centre, Faculty of Computing, Information Systems and Mathematics, London (United Kingdom); Qanadli, Salah D. [University Hospital Lausanne (CHUV), Department of Radiology, Lausanne (Switzerland)]|[BH-07, Centre Hospitalier Universitaire Vaudois, Service de Radiodiagnostic et de Radiologie interventionnelle, Lausanne (Switzerland)

    2009-03-15

    The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3{+-}3.4, coronary sinus 34.2{+-}4.1, sino-tubular junction 29.7{+-}3.4 and mid ascending aorta 32.7{+-}3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6{+-}11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1{+-}3.7, and between both coronary ostia 7.2{+-}3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9{+-}9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6{+-}3.3, CV 13-43%. Mean aortic valve area was 582.0{+-}131.9 mm{sup 2}. The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered. (orig.)

  5. Feasibility and accuracy of coronary imaging in elderly patients using the 64-row multi-detector computed tomography: a correlation study with conventional coronary angiography

    Institute of Scientific and Technical Information of China (English)

    Wei Ling CHAN; Kui Hian SIM; Chee Khoon LIEW; Sze Piaw CHIN; Tiong Kiam ONG; Seyfarth Tobias; Yean Yip FONG; Choon Kiat ANG; Houng Bang LIEW; Rapaee ANNUAR

    2006-01-01

    Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and accuracy of using 64-row multi-detector computed tomography (MDCT) in the assessment of coronary artery stenoses in elderly patients. Methods One hundred and fifty two patients with suspected or known coronary artery disease were divided into 4 groups according to their age (Group A: 40-49 years,n=34; Group B: 50-59 years, n=57; Group C: 60-69 years, n=48; Group D: 70 years and above; n=13). Coronary CT angiography (CTA) using a 64-row MDCT was performed and the findings were compared with that of conventional coronary angiography (CCA).Using axial images, multi-planar reconstructions (MPR) and maximum intensity projections (MIP), coronary segments of lumen diameter = 1.5mm were analyzed for the presence of significant stenosis (= 50% ). Results Percentages of poor image quality from coronary CTA preventing reliable correlations with CCA were 21%, 14%, 19% and 62% in Groups A to D respectively. Patients in Group D had significantly higher calcium scores compared with the other groups (P<0.001). In patients where CTA images were of acceptable quality, percentages of accurate correlations with CCA were 89.8%, 93.4%, 86.6% and 78.0% for Groups A to D respectively.There were no significant difference in serum creatinine, heart rate and contrast volume between the 4 groups. Conclusions The 64-row MDCT coronary angiography was less accurate and feasible for patients aged 70 years or above due to heavy coronary calcification and inability to perform a satisfactory breath-hold. However, a high diagnostic accuracy with the MDCT is possible in patients aged less than 70 years.

  6. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy); Scaglione, Mariano [Department of Diagnostic Imaging, Cardarelli Hospital, Naples Italy-Via G. Merliani 31, 80127 Naples (Italy)], E-mail: mscaglione@tiscali.it

    2008-03-15

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections.

  7. Criteria for establishing shielding of multi-detector computed tomography (MDCT) rooms.

    Science.gov (United States)

    Verdun, F R; Aroua, A; Baechler, S; Schmidt, S; Trueb, P R; Bochud, F O

    2010-01-01

    The aim of this work is to compare two methods used for determining the proper shielding of computed tomography (CT) rooms while considering recent technological advances in CT scanners. The approaches of the German Institute for Standardisation and the US National Council on Radiation Protection and Measurements were compared and a series of radiation measurements were performed in several CT rooms at the Lausanne University Hospital. The following three-step procedure is proposed for assuring sufficient shielding of rooms hosting new CT units with spiral mode acquisition and various X-ray beam collimation widths: (1) calculate the ambient equivalent dose for a representative average weekly dose length product at the position where shielding is required; (2) from the maximum permissible weekly dose at the location of interest, calculate the transmission factor F that must be taken to ensure proper shielding and (3) convert the transmission factor into a thickness of lead shielding. A similar approach could be adopted to use when designing shielding for fluoroscopy rooms, where the basic quantity would be the dose area product instead of the load of current (milliampere-minute).

  8. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)]. E-mail: Sabbara@partners.org; Desai, Jay C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Butler, Javed [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States); Reddy, Vivek [Division of Cardiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA (United States)

    2006-03-15

    A sizable portion of ventricular tachycardia circuits are epicardial, especially in patients with non-ischemic cardiomyopathy, e.g. Chagas disease. Thus there is a growing interest among the electrophysiologists in transepicardial mapping and myocardial ablation for treatment of arrhythmias. However, increased epicardial fat can be a significant hindrance in procedural success as it can mimic infarct during mapping and can also decrease the effectiveness of ablation. Quantitative knowledge of epicardial fat pre-procedure can potentially significantly facilitate the conduct and outcomes of these procedures. In this study we assessed the epicardial fat distribution and thickness in vivo in 59 patients who underwent multi-detector computed tomography (MDCT) for coronary artery assessment using a 16-slice scanner. Multiplanar reconstructions were obtained in the ventricular short axis at the basal, mid ventricular, and near the apex level, and in a four-chamber view. In the short axis slices, we measured epicardial fat diameter in nine segments, and in the four-chamber view, it was measured in five segments. In grooved segments the maximum fat thickness was recorded, while in non-grooved segments thickness at three equally spaced points were averaged. The results were as follows starting clockwise: superior inter-ventricular (IV) groove (all measurements are in mm, in basal, mid ventricular, and apical levels, respectively) (11.2, 8.6, 7.3), left ventricular (LV) superior lateral wall (1.0, 1.5, 1.7), LV inferior lateral wall (1.3, 2.2, 3.5), inferior IV groove (9.2, 6.5, 6.1), right ventricular (RV) diaphragmatic wall (1.4, 0.2, 1.0), acute margin (9.2, 7.3, 7.8), RV anterior free wall inferior (6.8, 4.0, 4.7), RV anterior free wall superior (6.5, 3.2, 3.1), RV superior wall (5.6, 2.7, 4.0), We measured the following four-chamber segments: LV apex (2.8 mm), left atrio-ventricular (AV) groove (12.7), right AV groove (14.8), RV apex (4.8), and anterior IV groove (7

  9. Multi-detector computed tomography (MDCT findings of chemotherapy induced hepatic chan

    Directory of Open Access Journals (Sweden)

    Sieza Samir Abd-Allah

    2016-09-01

    Results: Forty patients (32 females and 8 males had hepatic changes due to effect of chemotherapy. The most common CT finding was fatty liver. Hepatic fatty changes were detected in 36/40 patients. These fatty changes were diffuse, focal fatty and diffuse with fatty spare area. Four patients had capsular retraction: 1 patient with HD and 3 patients with metastatic cancer breast. Veno-occlusive disease and biliary sclerosis were not detected.

  10. Serial changes of coronary atherosclerotic plaque: Assessment with 64-slice multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young; Kang, Doo Kyoung; Sun, Joo Sung; Choi, So Yeon [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2013-12-15

    Evaluate the progression of coronary atherosclerotic plaque during follow-up, and its association with cardiovascular risk factors. Fifty-six atherosclerotic patients with plaque were enrolled in this retrospective study. Patient's plaque was detected on repeat 64-slice multidetector CT scans with a mean interval of 25 ± 10 months changes in calcified and non-calcified plaque volumes and cardiovascular risk factors were assessed over time. Absolute and relative changes in plaque volume were compared, and the association between rapid progression and cardiovascular risk factors was determined. Diameter of the stenosis, length, calcified and non-calcified lesion plaque volumes increased significantly on follow-up CT. Absolute and relative annual changes in plaque volumes were significantly greater in non-calcified plaque (median, 22.7 mm{sup 3}, 90.4%) than in calcified plaque (median, 0.7 mm{sup 3}, 0%). Obesity, smoking, hypertension, hypercholesterolemia, and low high-density lipoprotein were significant predictors of progression of non-calcified plaque. Progression of calcified plaque was not associated with any cardiovascular risk factors. Coronary plaque volume increased significantly on follow-up CT. The rate of progression is related to non-calcified plaque than to calcified plaque. Cardiovascular risk factors are independently associated with the rapid progression of non-calcified plaque volume, but not associated with the progression of calcified plaque.

  11. Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moon Chan [Dept. of Diagnostic Radiology, Samsung Medical Center, Seoul (Korea, Republic of)

    2009-09-15

    To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation (0.625 mm x 64 ea), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of 40-80% of R-R interval and 120 mA (80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with

  12. Monitoring of smoking-induced emphysema with CT in a lung cancer screening setting : Detection of real increase in extent of emphysema

    NARCIS (Netherlands)

    Gietema, Hester A.; Schilham, Arnold M.; van Ginneken, Bram; van Klaveren, Rob J.; Lammers, Jan Willem J.; Prokop, Mathias

    2007-01-01

    Purose: To retrospectively establish the minimum increase in emphysema score (ES) required for detection of real Increased extent of emphysema with 95% confidence by using multi-detector row computed tomography (CT) in a lung cancer screening setting. Materials and Methods The study was a substudy o

  13. CT equipment and performance issues: radiation protection 162.

    Science.gov (United States)

    Edyvean, S

    2013-02-01

    Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in parallel, this has been achieved with improvement in image quality and radiation dose efficiency. Despite this, and perhaps because image quality can always be improved at the expense of increased radiation dose, CT examinations are among the highest-dose procedures encountered routinely in medical imaging. The qualitative criteria for acceptability in RP 162 address some functional and operational issues, and the quantitative criteria, in the form of suspension levels, focus primarily around hardware aspects of the CT scanner, though consideration is also given to software, operator aspects and selection of scan protocols. Some of the specific aspects and challenges in modern CT systems, in particular multi-slice and wide beams are also addressed.

  14. Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Marano, Riccardo; Storto, Maria Luigia; Maddestra, Nicola; Bonomo, Lorenzo [Department of Clinical Sciences and Bioimaging, Section of Radiology, University ' ' G. d' Annunzio' ' , Ospedale ' ' SS. Annunziata' ' , Via dei Vestini, 66100, Chieti (Italy)

    2004-08-01

    The purpose of this study was to assess the accuracy of four-row multi-detector CT (MDCT) in the evaluation of coronary artery bypass graft (CABG) in patients with at least a left internal mammary artery (LIMA) grafted to the left anterior descending artery (LAD), because of the conduit of choice in bypass surgery and the greater difficulty of evaluation with non-invasive diagnostic tools. Included in the study were 57 patients with a total of 122 grafts (95 arterial and 27 venous) who underwent MDCT (4 x 2.5-mm detector-collimation, 3-mm slice width, 1.5-mm reconstruction increment) with retrospective ECG gating. Twelve patients (21%) with high heart rates were given beta-blockers in order to obtain a heart rate {<=}70 bpm in all patients. The ECG-synchronized axial images, reconstructed in the mid-diastole, MPR, MIP and 3D-VR images were independently and blindly assessed by two radiologists for graft patency and presence of high grade stenosis. Conventional angiography was the standard of reference. MDCT correctly classified 92/94 patent grafts and 26/28 occluded grafts (sensitivity/specificity 93%/97.8%); sensitivity and specificity of MDCT for assessment of arterial grafts were 100 and 98.7% (77/78 patent grafts and 17/17 occluded grafts). Image quality was considered adequate for assessment of significant stenoses in 62/92 (67%) patent grafts, with a significant differences between LIMA and non-LIMA conduits (44/57 vs. 18/65; P=0.002), according to the coronary vessel area supplied (anterior>lateral>posterior-inferior wall; P=0.002). In the remaining 30 patent grafts (33%), the assessment of stenoses was hampered by surgical clips, calcifications and motion artifacts. Sensitivity and specificity of MDCT for detection of significant graft stenoses were 80 and 96%, respectively. Inter-observer agreement was good (K=0.73). MDCT seems to be a valuable diagnostic tool for non-invasive assessment of patency of both venous and arterial grafts. An accurate evaluation

  15. Brain volume perfusion CT performed with 128-detector row CT system in patients with cerebral gliomas: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Xyda, Argyro [University Hospital of Goettingen, Department of Neuroradiology, Georg-August University, Goettingen (Germany); University Hospital of Heraklion, Department of Radiology, Crete (Greece); Haberland, Ulrike; Klotz, Ernst [Computed Tomography, Siemens AG Healthcare Sector, Forchheim (Germany); Bock, Hans Christoph [University Hospital of Goettingen, Department of Neurosurgery, Georg-August University, Goettingen (Germany); Jung, Klaus [University Hospital of Goettingen, Department of Medical Statistics, Georg-August University, Goettingen (Germany); Knauth, Michael; Schramm, Ramona; Psychogios, Marios Nikos; Schramm, Peter [University Hospital of Goettingen, Department of Neuroradiology, Georg-August University, Goettingen (Germany); Erb, Gunter [Bracco Imaging Deutschland GmbH, Konstanz (Germany)

    2011-09-15

    Validation of the feasibility and efficacy of volume perfusion computed tomography (VPCT) in the preoperative assessment of cerebral gliomas by applying a 128-slice CT covering the entire tumour. Forty-six patients (25 men, 21 women; mean age 52.8 years) with cerebral gliomas were evaluated with VPCT. Two readers independently evaluated VPCT data, drawing volumes of interest (VOIs) around the tumour according to maximum intensity projection volumes, which were mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability (Ktrans) perfusion datasets. As control, a second VOI was placed in the contralateral healthy cortex. Correlation among perfusion parameters, tumour grade, hemisphere and VOIs was assessed. The diagnostic power of perfusion parameters was analysed by receiver operating characteristics curve analyses. VPCT was feasible in the assessment of the entire tumour extent. Mean values of Ktrans, CBV, CBF in high-grade gliomas were significantly higher compared with low-grade (p < 0.01). Ktrans demonstrated the highest diagnostic (97% sensitivity), positive (100%) and negative (94%) prognostic values. VPCT was feasible in all subjects. All areas of different perfusion characteristics are depicted and quantified in colour-coded 3D maps. The derived parameters correlate well with tumour histopathology, differentiating low- from high-grade gliomas. (orig.)

  16. Role of multiphasic multi-detector computed tomography (MDCT in the diagnosis and staging of solid neoplastic renal masses

    Directory of Open Access Journals (Sweden)

    Manal H. Wahba

    2015-03-01

    Conclusion: Multiphase multislice computed tomography combined with CT angiography and CT urography have a major role in solid renal neoplastic masses’ diagnosis, characterization and differentiating benign and malignant tumors.

  17. Discordant findings of dimercaptosuccinic acid scintigraphy in children with multi-detector row computed tomography-proven acute pyelonephritis

    Directory of Open Access Journals (Sweden)

    Jeongmin Lee

    2011-05-01

    Full Text Available Purpose : The diagnosis of acute pyelonephritis (APN is often difficult, as its clinical and biological manifestations are non-specific in children. If not treated quickly and adequately, however, APN may cause irreversible renal damage, possibly leading to hypertension and chronic renal failure. We were suspecting the diagnostic value of 99mTc-dimercaptosuccinic acid (DMSA scan by experiences and so compared the results of DMSA scan to those of multi-detector row computed tomography (MDCT. Methods : We retrospectively selected and analyzed 81 patients who were diagnosed as APN by MDCT during evaluation of their acute abdomen in emergency room and then received DMSA scan also for the diagnostic work-up of APN after admission. We evaluated the results of imaging studies and compared the diagnostic value of each method by age groups, &lt;2 years (n=45 and ?#242; years (n=36. Results : Among total 81 patients with MDCT-proven APN, DMSA scan was diagnostic only in 55 children (68%, while the remaining 26 children (32% showed false negative normal findings. These 26 patients were predominantly male and most of them, 19 (73.1% were &lt;2 years of age. Conclusion : DMSA scan holds obvious limitation compared to MDCT in depicting acute inflammatory lesions of kidney in children with APN, especially in early childhood less than 2 years of age. MDCT showed hidden lesions of APN, those were undetectable through DMSA scan in children.

  18. Three-dimensional contrasted visualization of pancreas in rats using clinical MRI and CT scanners.

    Science.gov (United States)

    Yin, Ting; Coudyzer, Walter; Peeters, Ronald; Liu, Yewei; Cona, Marlein Miranda; Feng, Yuanbo; Xia, Qian; Yu, Jie; Jiang, Yansheng; Dymarkowski, Steven; Huang, Gang; Chen, Feng; Oyen, Raymond; Ni, Yicheng

    2015-01-01

    The purpose of this work was to visualize the pancreas in post-mortem rats with local contrast medium infusion by three-dimensional (3D) magnetic resonance imaging (MRI) and computed tomography (CT) using clinical imagers. A total of 16 Sprague Dawley rats of about 300 g were used for the pancreas visualization. Following the baseline imaging, a mixed contrast medium dye called GadoIodo-EB containing optimized concentrations of Gd-DOTA, iomeprol and Evens blue was infused into the distally obstructed common bile duct (CBD) for post-contrast imaging with 3.0 T MRI and 128-slice CT scanners. Images were post-processed with the MeVisLab software package. MRI findings were co-registered with CT scans and validated with histomorphology, with relative contrast ratios quantified. Without contrast enhancement, the pancreas was indiscernible. After infusion of GadoIodo-EB solution, only the pancreatic region became outstandingly visible, as shown by 3D rendering MRI and CT and proven by colored dissection and histological examinations. The measured volume of the pancreas averaged 1.12 ± 0.04 cm(3) after standardization. Relative contrast ratios were 93.28 ± 34.61% and 26.45 ± 5.29% for MRI and CT respectively. We have developed a multifunctional contrast medium dye to help clearly visualize and delineate rat pancreas in situ using clinical MRI and CT scanners. The topographic landmarks thus created with 3D demonstration may help to provide guidelines for the next in vivo pancreatic MRI research in rodents.

  19. Diagnostic accuracy of triple-contrast multi-detector computed tomography for detection of penetrating gastrointestinal injury: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Saksobhavivat, Nitima [Faculty of Medicine Ramathibodi Hospital, Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ratchathewi, Bangkok (Thailand); Shanmuganathan, Kathirkamanathan; Boscak, Alexis R.; Sliker, Clint W.; Bodanapally, Uttam K.; Archer-Arroyo, Krystal; Miller, Lisa A.; Fleiter, Thorsten R.; Alexander, Melvin T.; Mirvis, Stuart E. [University of Maryland School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Baltimore, MD (United States); Stein, Deborah M.; Scalea, Thomas M. [University of Maryland School of Medicine, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States)

    2016-11-15

    Neither the performance of CT in diagnosing penetrating gastrointestinal injury nor its ability to discriminate patients requiring either observation or surgery has been determined. This was a prospective, single-institutional observational study of patients with penetrating injury to the torso who underwent CT. Based on CT signs, reviewers determined the presence of a gastrointestinal injury and the need for surgery or observation. The primary outcome measures were operative findings and clinical follow-up. CT results were compared with the primary outcome measures. Of one hundred and seventy-one patients (72 gunshot wounds, 99 stab wounds; age range, 18-57 years; median age, 28 years) with penetrating torso trauma who underwent CT, 45 % were followed by an operation and 55 % by clinical follow up. Thirty-five patients had a gastrointestinal injury at surgery. The sensitivity, specificity, and accuracy of CT for diagnosing a gastrointestinal injury for all patients were each 91 %, and for predicting the need for surgery, they were 94 %, 93 %, 93 %, respectively. Among the 3 % of patients who failed observation, 1 % had a gastrointestinal injury. CT is a useful technique to diagnose gastrointestinal injury following penetrating torso injury. CT can help discriminate patients requiring observation or surgery. (orig.)

  20. Contribution to data acquisition software of Eurogram and Diamant multi detectors in an Unix/VXWorks environment; Contribution aux logiciels d`acquisition de donnees des multidetecteurs Eurogam et Diamant dans un environnement reparti Unix/VXWorks

    Energy Technology Data Exchange (ETDEWEB)

    Diarra, C.

    1994-06-01

    Questions on nuclear matter, need to have new performant equipments. Eurogram is a 4 PI gamma radiations multi detector and a precious tool in gamma spectroscopy, but it is necessary to use a charged particles detector and in this aim Diamant is an Eurogram partner. These two multi detectors needed special software data acquisition systems. The whole of acquisition control and management is based on sun stations with unix system. 56 figs., 64 refs.

  1. Cost-effective pediatric head and body phantoms for computed tomography dosimetry and its evaluation using pencil ion chamber and CT dose profiler

    Directory of Open Access Journals (Sweden)

    A Saravanakumar

    2015-01-01

    Full Text Available In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP. Using these values, the weighted computed tomography dose index (CTDIw and in turn the volumetric CTDI (CTDIv were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB, India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.

  2. Perfusion CT in childhood stroke—Initial observations and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Zebedin, D., E-mail: doris.zebedin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria); Sorantin, E.; Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria)

    2013-07-15

    Introduction: To report the preliminary results of contrast-enhanced perfusion multi-detector CT for diagnoses of perfusion disturbances in children with clinical suspicion of stroke. Patients and methods: Within the last two years emergency perfusion CT was performed in ten children (age: 8–17 years, male:female = 3:7) for assessment of suspected childhood stroke. These intracranial perfusion CT, intracranial CT-digital subtraction angiography (CT-DSA) and extracranial CT-angiography (CTA) studies were retrospectively reviewed and compared with MRI, follow-up CT, catheter angiography and final clinical diagnosis. The total dose length product (DLP) for the entire examination was recorded. The image quality of perfusion CT-maps, CT-DSA and CTA were evaluated with a subjective three-point scale ranging from very good to non-diagnostic image quality rating perfusion disturbance, intracranial peripheral vessel depiction, and motion- or streak artifacts. Results: In nine of ten children perfusion CT showed no false positive or false negative results. In one of ten children suffering from migraine focal hypo-perfusion was read as perfusion impairment potentially indicating early stroke, but MRI and MRA follow-up were negative. Overall, perfusion-CT with CT-DSA was rated very good in 80% of cases for the detection of perfusion disturbances and vessel anatomy. Conclusions: In comparison to standard CT, contrast-enhanced perfusion CT improves CTs’ diagnostic capability in the emergency examination of children with a strong suspicion of ischemic cerebral infarction.

  3. Thoracic CT

    Science.gov (United States)

    ... lungs; CT scan - chest Images CT scan Thyroid cancer - CT scan Pulmonary nodule, solitary - CT scan Lung mass, right upper ... Chest Injuries and Disorders CT Scans Emphysema Lung Cancer Lung Diseases Pleural Disorders Pneumonia Pulmonary Embolism Tuberculosis Browse the Encyclopedia A.D.A. ...

  4. Relevant incidental findings at abdominal multi-detector contrast-enhanced computed tomography:A collateral screening?

    Institute of Scientific and Technical Information of China (English)

    Luca; Maria; Sconfienza; Giovanni; Mauri; Claudia; Muzzupappa; Alessandro; Poloni; Michele; Bandirali; Anastassia; Esseridou; Stefania; Tritella; Francesco; Secchi; Giovanni; Di; Leo; Francesco; Sardanelli

    2015-01-01

    AIM: To investigate the prevalence of relevant incidental findings(RIFs) detected during routine abdominal contrast-enhanced computed tomography(Ce CT).METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal Ce CT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs(if needing additional workup) was noted.RESULTS: One thousand forty abdominal Ce CT were performed in 949 patients(528 males, mean age 66 ±14 years). No significant difference was found between inpatients and outpatients age and sex distribution(P > 0.472). RIFs were found in 195/1040(18.8%) Ce CT [inpatients = 108/470(23.0%); outpatients = 87/570(15.2%); P = 0.002]. RIFs were found in 30/440(6.8%) Ce CT with a previous exam and in 165/600(27.5%) without a previous exam(P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different(P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs.CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal Ce CT. Risk of overdiagnosis should be taken into account.

  5. Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Ruifang Zhang

    Full Text Available BACKGROUND AND PURPOSE: Accurate measurement of aortic annulus diameter is crucial for choosing suitable prosthetic size for transcatheter aortic valve implantation (TAVI. Several imaging methods are available for the measurement, but significant variability between different modalities has been observed. The purpose of this study was to systematically compare the measurements of aortic annulus diameter between multi-detector computed tomography (MDCT, transthoracic echocardiography (TTE, and transesophegeal echocardiography (TEE. METHODS: PubMed and EMBASE databases between January 2000 and January 2012 were searched. We extracted data from eligible studies evaluating the aortic annulus diameter by MDCT and echocardiography (TTE, TEE, or both. We performed a random-effects meta-analysis to calculate the weighted mean differences of aortic annulus diameter measurement between MDCT, TTE, and TEE. RESULTS: A total of 10 eligible studies involving 581 subjects with aortic valve stenosis were included. Aortic annulus diameter measured on coronal view by MDCT (25.3±0.52 mm was respectively larger than that measured on sagittal view by MDCT (22.7±0.37 mm, TTE (22.6±0.28 mm, and TEE (23.1±0.32 mm. The weighted mean difference of aortic annulus diameter between coronal view by MDCT and TTE these two methods was 2.97 mm, followed by the weighted mean difference of 2.53 mm between coronal view and sagittal view by MDCT, and the mean difference of 1.74 mm between coronal view on MDCT and TEE (P<0.0001 for all. The weighted mean difference of aortic annulus diameter measurement between TEE and TTE was significant but somewhat small (0.45 mm, P = 0.007. CONCLUSION: Aortic annulus diameter measured on coronal view by MDCT was robustly and significantly larger than that obtained on sagittal view by MDCT, TTE, or TEE. Such variability of aortic annulus diameter measurement by different imaging modalities cannot be ignored when developing optimal

  6. Delayed enhancement imaging of myocardial viability: low-dose high-pitch CT versus MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert; Feuchtner, Gudrun; Stolzmann, Paul; Donati, Olivio F.; Frauenfelder, Thomas; Leschka, Sebastian; Alkadhi, Hatem [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Wieser, Monika; Plass, Andre [University Hospital Zurich, Division of Cardiac and Vascular Surgery, Zurich (Switzerland)

    2011-10-15

    To evaluate the accuracy of high-pitch delayed enhancement (DE) CT for the assessment of myocardial viability with MRI as the reference standard. Twenty-four patients (mean age 66.9 {+-} 9.2 years) with coronary artery disease underwent DE imaging with 128-slice dual-source CT (prospective electrocardiography (ECG)-triggering) and MRI at 1.5 T. Two observers assessed DE transmurality per segment, and measured signal intensity (MRI) or attenuation (CT) in infarcted and healthy myocardium and noise in the left ventricular blood pool for calculating contrast-to-noise ratios (CNR). 75/408 (18.4%) segments in 18/24 patients (75.0%) showed DE in MRI, of which 28 segments in 10/24 (41.7%) patients were non-viable (scar tissue transmurality >50%). Sensitivity, specificity and accuracy of CT for diagnosis of non-viability were 60.7%, 96.8% and 94.4% per segment, and 90.0%, 92.9% and 91.7% per patient. CNR was significantly higher in MR (7.4 {+-} 3.0 vs. 4.6 {+-} 1.5; p = 0.018), and image noise significantly lower (11.6 {+-} 5.7 vs.15.0 {+-} 4.5; p = 0.019). Radiation dose of DECT was 0.89 {+-} 0.07 mSv. CTDE imaging in the high-pitch mode enables myocardial viability assessment at a low radiation dose and good accuracy compared with MR, although associated with a lower CNR and higher noise. (orig.)

  7. Coronary artery anomalies: Assessment with electrocardiography-gate multidetector-row CT at a single center in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Bo Ram; Sun, Joo Sung; Yang, Hyoung Mo; Kang, Doo Kyoung [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2015-04-15

    To determine the prevalence of coronary anomalies using coronary computed tomography angiography (CCTA) and to evaluate the relationship between coronary artery anomalies and chest pain. A total of 12676 patients underwent CCTA scans at our institution between December 2006 and April 2013 using a 64-slice CT and a 128-slice dual-source CT. We determined the prevalence of coronary artery anomalies according to the classification system proposed by Greenberg. The presence or absence of chest pain with each coronary artery anomaly was also evaluated. Coronary anomalies were found in 176 patients (1.39%) at our institute. Anomalies of origination, course, and termination were detected in 118 (0.93%), 28 (0.22%), and 30 (0.24%) patients, respectively. After the exclusion of 32 patients with combined heart disease, typical (n = 16; 11.1%) or atypical (n = 28; 19.4%) chest pain was present in 44 (30.6%) of the 144 patients at the time of diagnosis. The prevalence of coronary artery anomalies was 1.39% at our hospital. After the exclusion of patients with combined heart disease, 11.1% had typical chest pain at the time of diagnosis.

  8. Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yang; Ma, Yue; Wang, Yuke; Yu, Mei; Guo, Qiyong [Shengjing Hospital of China Medical University, Department of Radiology, Shenyang (China); Fan, Weipeng [Central Hospital of Anshan, Department of Radiology, Anshan (China); Vembar, Mani [CT Clinical Science Philips Healthcare, Cleveland, OH (United States)

    2014-01-15

    To evaluate the accuracy of low-dose coronary CTA with iterative reconstruction (IR) in the diagnosis of coronary artery disease (CAD) in patients with suspected CAD. Ninety-six patients with suspected CAD underwent low-dose prospective electrocardiogram-gated coronary CTA, with images reconstructed using IR. Image quality (IQ) of coronary segments were graded on a 4-point scale (4, excellent; 1, non-diagnostic). With invasive coronary angiography (ICA) considered the ''gold standard'', the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of coronary CTA were calculated on segment-, vessel- and patient-based levels. The patient data were divided into two groups (Agatston scores of ≥ 400 and <400). The differences in diagnostic performance between the two groups were tested. Diagnostic image quality was found in 98.1 % (1,232/1,256) of segments. The sensitivity, specificity, PPV, NPV and accuracy were 90.8 %, 95.3 %, 81.8 %, 97.8 % and 94.3 % (segment-based) and 97.2 %, 83.3 %, 94.6 %, 90.9 % and 93.8 % (patient-based). Significant differences between the two groups were seen in specificity, PPV and accuracy (92.1 % vs. 97.9 %, 76.0 % vs. 86.7 %, 91.7 % vs. 96.6 %, P < 0.05; segment-based). The average effective dose was 1.30 ± 0.15 mSv. Low-dose prospective coronary CTA with IR can acquire satisfactory image quality and show high diagnostic accuracy in patients with suspected CAD; however, blooming continues to pose a challenge in severely calcified segments. (orig.)

  9. Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone

    Energy Technology Data Exchange (ETDEWEB)

    Frellesen, Claudia; Stock, Wenzel; Kerl, J.M.; Lehnert, Thomas; Wichmann, Julian L.; Beeres, Martin; Schulz, Boris; Bodelle, Boris; Vogl, Thomas J. [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Nau, Christoph; Geiger, Emanuel; Wutzler, Sebastian [Clinic of the Goethe University, Department of Trauma, Hand and Reconstructive Surgery, Frankfurt (Germany); Ackermann, Hanns [Clinic of the Goethe University, Department of Biostatistics and Mathematical Modelling, Frankfurt (Germany); Bauer, Ralf W. [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Klinikum der Goethe-Universitaet, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany)

    2014-07-15

    To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modulation only. Another 100 patients underwent 128-slice CT with automated mA modulation and topogram-based automated tube potential selection (autokV) at 100, 120 or 140 kV. Volume CT dose index (CTDI{sub vol}), dose-length product (DLP), body diameters, noise, signal-to-noise ratio (SNR) and subjective image quality were compared. In the autokV group, 100 kV was automatically selected in 82 patients, 120 kV in 12 patients and 140 kV in 6 patients. Patient diameters increased with higher kV settings. The median CTDI{sub vol} (8.3 vs. 12.4 mGy; -33 %) and DLP (594 vs. 909 mGy cm; -35 %) in the entire autokV group were significantly lower than in the group with fixed 120 kV (p < 0.05 for both). Image quality remained at a constantly high level at any selected kV level. Topogram-based automated selection of the tube potential allows for significant dose savings in thoraco-abdominal trauma CT while image quality remains at a constantly high level. (orig.)

  10. Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ganten, Maria-Katharina [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany); Krautter, Ute; Tengg-Kobligk, Hendrik von; Delorme, Stefan; Kauczor, Hans-Ulrich [Deutsches Krebsforschungszentrum, Department of Radiology, Medical Physics in Radiology, Heidelberg (Germany); Boeckler, Dittmar; Schumacher, Hardy [Ruprecht-Karls-University of Heidelberg, Department of Vascular and Endovascular Surgery, Heidelberg (Germany); Stiller, Wolfram; Bock, Michael [Deutsches Krebsforschungszentrum, Department of Medical Physics in Radiology, Medical Physics in Radiology, Heidelberg (Germany); Kauffmann, Guenter W. [Ruprecht-Karls-University of Heidelberg, Department of Diagnostic Radiology, Heidelberg (Germany)

    2008-05-15

    To detect distensibility changes that might be an indicator for an increased risk of rupture, cross-sectional area changes of abdominal aortic aneurysms (AAA) have been determined using ECG-gated CT. Distensibility measurements of the aorta were performed in 67 patients with AAA. Time-resolved images were acquired with a four detector-row CT system using a modified CT-angiography protocol. Pulsatility-related cross-sectional area changes were calculated above and at AAA level by semiautomatic segmentation; distensibility values were obtained using additional systemic blood pressure measurements. Values were compared for small Oe< 5 cm (n=44) and large Oe> 5 cm (n = 23) aneurysms. The aorta could be segmented successfully in all patients. Upstream AAA distensibility D was significantly higher than at AAA level for both groups: means above AAA (at AAA) D{sub above} = (1.3 {+-}0.8) .10 {sup -5} Pa {sup -1} (D{sub AAA} = (0.6 {+-}0.5) .10 {sup -5} Pa {sup -1}) t-test p{sub D}<0.0001. Differences of the distensibility between smaller and larger aneurysms were not found to be significant. Distensibility can be measured non-invasively with ECG-gated CT. The reduction of distensibility within aneurysms compared to normal proximal aorta is subtle; the lack of difference between both small and large aneurysms suggests that this reduction occurs early in the aneurysm's development. Hence, reduced distensibility might be a predictive parameter in patients with high risk of aortic disease. (orig.)

  11. [Multidetector row CT in assessment of coronary artery calcification on hemodialisis].

    Science.gov (United States)

    Caro, P; Delgado, R; Dapena, F; Núñez, A

    2007-01-01

    Vascular calcification is a strong predictor of cardiovascular and all-cause mortality. Coronary artery calcification is more frequent, more extensive and progresses more rapidly in CKD than in general population. They are also considered a marker of coronary heart disease, with high prevalence and functional significance. It suggests that detection and surveillance may be worthwhile in general clinical practice. New non-invasive image techniques, like Multi-detector row CT, a type of spiral scanner, assess density and volume of calcification at multiple sites and allow quantitative scoring of vascular calcification using calcium scores analogous to those from electron-beam CT. We have assessed and quantified coronary artery calcification with 16 multidetector row CT in 44 patients on hemodialysis and their relationship with several cardiovascular risk factors. Coronary artery calcification prevalence was of 84 % with mean calcium score of 1580 +/- 2010 ( r 0-9844) with calcium score > 400 in 66% of patients. It was usually multiple, affecting more than two vessels in more than 50%. In all but one patient, left anterior descending artery was involved with higher calcium score level at right coronary artery. Advanced age, male, diabetes, smoking, more morbidity, cerebrovascular disease previous, and calcium-binders phosphate and analogous vitamin D treatment would seem to be associated with coronary artery calcification. Coronary artery calcification is very frequent and extensive, usually multiple and associated to modifiable risk factors in hemodialysis patients. Multi-detector-row CT seems an effective, suitable, readily applicable method to assess and quantify coronary artery calcification.

  12. Cardiac CT for the assessment of chest pain: Imaging techniques and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Hans-Christoph, E-mail: christoph.becker@med.uni-muenchen.de [Ludwig-Maximilians-University, Grosshadern Clinic, Department of Clinical Radiology, Marchioninistr. 15, 81377 Munich (Germany); Johnson, Thorsten [Ludwig-Maximilians-University, Grosshadern Clinic, Department of Clinical Radiology, Marchioninistr. 15, 81377 Munich (Germany)

    2012-12-15

    Immediate and efficient risk stratification and management of patients with acute chest pain in the emergency department is challenging. Traditional management of these patients includes serial ECG, laboratory tests and further on radionuclide perfusion imaging or ECG treadmill testing. Due to the advances of multi-detector CT technology, dedicated coronary CT angiography provides the potential to rapidly and reliably diagnose or exclude acute coronary artery disease. Life-threatening causes of chest pain, such as aortic dissection and pulmonary embolism can simultaneously be assessed with a single scan, sometimes referred to as “triple rule out” scan. With appropriate patient selection, cardiac CT can accurately diagnose heart disease or other sources of chest pain, markedly decrease health care costs, and reliably predict clinical outcomes. This article reviews imaging techniques and clinical results for CT been used to evaluate patients with chest pain entering the emergency department.

  13. Guideline for appropriate use of cardiac CT in heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin; Hong, Yoo Jin [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yong, Hwan Seok [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Sung Mok [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jeong A [Dept. of Radiology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang (Korea, Republic of); Yang, Dong Hyun [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    Heart disease is one of the leading causes of deaths in Korea, along with malignant neoplasms and cerebrovascular diseases. The proper diagnosis and management for patients with suspected heart diseases should be warranted for the public health care. Advances in CT technology have allowed detailed images of the heart to be obtained, which enable evaluations not only of the coronary arteries but also of other cardiac structures. Currently, the latest multi-detector CT machines are widespread around Korea. The appropriate use of cardiac CT may lead to improvements of the physicians' medical performances and to reduce medical costs which eventually contribute to promotions of public health. However, until now, there has been no guidelines regarding the appropriate use of cardiac CT in Korea. We intend to provide guidelines for the appropriate use of cardiac CT in heart diseases based on scientific data. The purpose of this guideline is to assist the clinicians and other health professionals when using cardiac CT for diagnosis and treatments of heart diseases.

  14. Angiotomografía computada multicorte 64 en patología de la arteria aorta The 64 multi detector row computed tomography in aortic patology diagnostic

    Directory of Open Access Journals (Sweden)

    Diego Haberman

    2008-09-01

    Full Text Available La angiotomografía computada representa una metodología diagnóstica de gran utilidad que ha cobrado mayor importancia con los nuevos avances tecnológicos. La tomografía computada multicorte con 64 hileras de detectores nos brinda la posibilidad de estudiar con gran precisión y enorme detalle estructuras cada vez más pequeñas, ofreciendo una nueva perspectiva en el diagnóstico de la patología aórtica.The angio computed tomography represents a great utility diagnostic method that has reached greater importance with its technological new developments. The 64 multi detector row computed tomography allows the evaluation with great precision and detail of very small structures, offering a new perspective in aortic patology diagnostic.

  15. Head CT scan

    Science.gov (United States)

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... hold your breath for short periods. A complete scan usually take only 30 seconds to a few ...

  16. Is intravenous contrast enhancement effective in improving CT diagnosis of hepatic disease?

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Katsuhide; Ono, Chiaki [Hiroshima Univ. (Japan). Hospital; Kohno, Atsushi[Japanese Foundation for Cancer Research, Tokyo (Japan). Hospital; Sumi, Yukiharu [Juntendo Univ., Chiba (Japan). Urayasu Hospital; Honda, Masanori [Saiseikai Utsunomiya Hospital (Japan); Uchimura, Fumiaki [Yamagata Prefectural Nihonkai Hospital, Sakata (Japan); Ogawa, Kenji [Nihon Koukan Hospital, Kawasaki, Kanagawa (Japan); Ohtaki, Megu [Hiroshima Univ. (Japan). Research Inst. for Radiation Biology and Medicine

    2003-03-01

    The purpose of this study was to evaluate the effectiveness of contrast enhancement in the diagnosis of hepatic disease. 2761 cases involving CT of the liver and abdomen were analyzed using logistic analysis. CT was either helical-CT (SDCT) or multi-detector CT (MDCT), with power injector. Contrast enhancement use was 92% in liver disease and 95% in tumor cases. A typical case involved a 66-year-old man given 2-4 ml/sec of contrast material using dual injection. CT imaging was done in the equilibrium stage. The use of contrast material was effective for the diagnosis of liver tumor except in the qualitative diagnosis of hepatocellular carcinoma with SDCT where the odds ratio was 0.084. Intravenous contrast enhancement was effective for the CT diagnosis of hepatic tumor. Dynamic CT was effective using MDCT, and dual injection of contrast material was also valid for SDCT. Multiphasic studies were needed for detecting liver tumors not only on MDCT but also on SDCT. CT imaging during the equilibrium phase alone is inadequate to document diagnosis of metastatic liver tumors. The addition of various phasic contrast materials during CT was effective in evaluating liver tumors that showed angiogenesis. (author)

  17. Serial CT Findings of Paragonimus Infested Dogs and the Micro-CT Findings of the Worm Cysts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hyun; Im, Jung Gi; Goo, Jin Mo; Lee, Hyun Ju; Hong, Sung Tae; Shen, Cheng Hua; Chung, Doo Hyun; Son, Kyu Ri; Chang, Jung Min; Eo, Hong [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-10-15

    To investigate the serial CT findings of Paragonimus westermani infected dogs and the microscopic structures of the worm cysts using Micro-CT. This study was approved by the committee on animal research at our institution. Fifteen dogs infected with P. westermani underwent serial contrast-enhanced CT scans at pre-infection, after 10 days of infection, and monthly thereafter until six months for determining the radiologic-pathologic correlation. Three dogs (one dog each time) were sacrificed at 1, 3 and 6 months, respectively. After fixation of the lungs, both multi-detector CT and Micro-CT were performed for examining the worm cysts. The initial findings were pleural effusion and/or subpleural groundglass opacities or linear opacities at day 10. At day 30, subpleural and peribronchial nodules appeared with hydropneumothorax and abdominal or chest wall air bubbles. Cavitary change and bronchial dilatation began to be seen on CT scan at day 30 and this was mostly seen together with mediastinal lymphadenopathy at day 60. Thereafter, subpleural ground-glass opacities and nodules with or without cavitary changes were persistently observed until day 180. After cavitary change of the nodules, the migratory features of the subpleural or peribronchial nodules were seen on all the serial CT scans. Micro-CT showed that the cyst wall contained dilated interconnected tubular structures, which had communications with the cavity and the adjacent distal bronchus. The CT findings of paragonimiasis depend on the migratory stage of the worms. The worm cyst can have numerous interconnected tubular channels within its own wall and these channels have connections with the cavity and the adjacent distal bronchus.

  18. Coronary CT angiography in symptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.R. [Inst. of Radiologic Diagnostic, Univ. of Munich, Klinikum Grosshadern, Munich (Germany)

    2005-02-01

    The currently best available spatial and temporal resolution for retrospectively ECG gated coronary multi-detector-row CT angiography is 0.4 mm and 165 ms, respectively. These acquisition parameters are already rather close to cardiac catheter. Studies so far compared non-invasive coronary CT and convention angiography for the detection of coronary artery stenoses. The most promising result reported by all authors was the high negative predictive value of the CTA. It now needs to be determined if CTA is a reliable tool to rule out coronary artery stenoses in a patient cohort with low likelihood of CAD, such as those with atypical chest pain or ambiguous stress test. CTA may furthermore establish as a rapid and widely available tool to detect vulnerable plaques or intracoronary thrombus in patients with acute coronary syndrome and unstable angina. In patients with chronic stable angina, tools that determine myocardial ischemia under stress such as SPECT and MRI are probably better suited to determine the relevance of coronary artery stenoses. In this particular cohort, by displaying the extent and morphology of coronary atherosclerosis, CTA may help to direct the therapy to either intervention or surgery. (orig.)

  19. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke;

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  20. Perfusion computed tomography for diffuse liver diseases; Perfusions-CT bei diffusen Lebererkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, S.A.; Juchems, M.S. [Universitaetsklinikum Ulm, Klinik fuer Diagnostische und Interventionelle Radiologie, Ulm (Germany)

    2012-08-15

    Perfusion computed tomography (CT) has its main application in the clinical routine diagnosis of neuroradiological problems. Polyphase multi-detector spiral computed tomography is primarily used in liver diagnostics. The use of perfusion CT is also possible for the diagnostics and differentiation of diffuse hepatic diseases. The differentiation between cirrhosis and cirrhosis-like parenchymal changes is possible. It also helps to detect early stages of malignant tumors. However, there are some negative aspects, particularly that of radiation exposure. This paper summarizes the technical basics and possible applications of perfusion CT in cases of diffuse liver disease and weighs up the advantages and disadvantages of the examinations. (orig.) [German] Die Perfusions-CT hat ihren hauptsaechlichen Stellenwert bislang in der klinischen Routinediagnostik bei neuroradiologische Fragestellungen. In der Leberdiagnostik kommt v. a. die mehrphasige Multidetektor-Spiral-CT-Untersuchung zum Einsatz. Die Anwendung der Perfusions-CT ist auch bei der Diagnostik und Differenzierung diffuser Lebererkrankungen moeglich. Die Unterscheidung zwischen einer Leberzirrhose und zirrhoseaehnlichen Parenchymveraenderungen ist mit der Perfusions-CT moeglich. Ebenso liefert sie einen wertvollen Beitrag zur Diagnostik bei der Frueherkennung entstehender maligner Herdbefunde. Diesen Vorteilen stehen jedoch auch einige negative Aspekte gegenueber, insbesondere die relativ hohe Strahlenexposition. Die vorliegende Arbeit soll einen Ueberblick ueber die technischen Grundlagen und die Anwendungsmoeglichkeiten der Perfusions-CT bei diffusen Lebererkrankungen geben sowie die Vor- und Nachteile der Untersuchung gegeneinander abwaegen. (orig.)

  1. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    Energy Technology Data Exchange (ETDEWEB)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip [Eskisehir Osmangazi University, Eskisehir (Turkmenistan)

    2008-12-15

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE.

  2. Comparison of ventilation/perfusion scintigraphy and multi-detector computerized tomography in diagnosis of asymptomatic pulmonary embolism after deep vein thrombosis

    Directory of Open Access Journals (Sweden)

    Eflatun Yücedağ

    2014-03-01

    Full Text Available Objective: Pulmonary thromboembolism (PTE named due to migration of clots formed in systemic venous system to pulmonary vascular bed is a serious clinical table. After acute DVT, asymptomatic PTE is seen about 40-60% and this situation can not be discovered because of silent clinical course. In this study, we aimed to compare sensivity and spesifity of multi detector computerized tomography (MDCT, which is used extensively in recent years, with ventilation-perfusion (V/P scintigraphy which is used formerly for diagnosis of asymptomatic PTE developed after acute lower extremity DVT. Methods: The study was carried out 25 patients who were admitted to our clinic and treated for lower extremity acute DVT. Pregnants, and cases with recurrent DVT, presence of symptomatic PTE during admission, thrombosis extending to vena cava, and history of passed PTE were excluded from the study. DVTs in patients were diagnosed by color doppler, and confirmed by D-dimer test. After patients’s admission, V/P scintigraphy and MDCT were used to detects asymptomatic PTE at 1st and 8 th day of the admission. Results: D-dimer was measured as higher in 24 of 25 patients with asemptomatic PTE. Ten patients were diagnosed by MDCT. Development of asymptomatic PTE related to acute DVT was determined as 40%. Conclusion: In terms of diagnostic value, MDCT was found more useful than V/P scintigraphy.

  3. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, I.Chen [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Lin, Yung-Kai; Chang, Yen; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen [Taichung Veterans General Hospital, Section of Cardiovascular Surgery, Cardiovascular Center, Taichung (China); Fu, Yun-Ching; Jan, Sheng-Ling [Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Taichung Veterans General Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Taichung (China); Wang, Kuo-Yang [Taichung Veterans General Hospital, Section of General Cardiology, Cardiovascular Center, Taichung (China); Chung-Shan Medical University, Department of Medicine, Taichung (China); Chen, Min-Chi; Chen, Clayton Chi-Chang [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Central Taiwan University of Science and Technology, Department of Radiological Technology, Taichung (China)

    2009-04-15

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders. (orig.)

  4. Comparison of MDCTA (16-slice multi-detector row computed tomography arthrography) and MRA (magnetic resonance arthrography) for detecting labral lesions of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung A; Cha, Jang Gyu; Hong, Hyun Sook; Choi, Deuk Lin; Park, Jai Soung; Lee, Hae Kyung; Kim, Dae Ho [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2007-11-15

    To compare the accuracy of 16-slice multi-detector row computed tomographic arthrography (MDCTA) and magnetic resonance arthrography (MRA) for making the diagnosis and classification of labroligamentous injuries. This study is a prospective series that used MRA and MDCTA to examine 23 patients who complained of shoulder instability. Two radiologists independently analyzed the MRA and MDCTA. The sensitivity, specificity, accuracy, positive and negative predictive values were calculated from the arthrograms and the arthroscopic findings. The images of MDCTA and MRA corresponded with the findings on arthroscopy. Both imaging modalities had the same sensitivity for detecting Bankart lesions (n = 10, 90%) and posterior labral tears (n = 2, 50%) on McNemar test ({rho} = 1.00). For superior labrum anterior-to-posterior (SLAP) lesions, 6 MRA cases and 4 MDCTA cases corresponded with the arthroscopic findings. The difference between the sensitivities of MDCTA (66.7%) and MRA (100%) was not significant ({rho} 0.09). We suggest that the sensitivity of diagnosing labral lesions that induce shoulder instability is similar for MDCTA and MRA. MDCTA is effective for diagnosing and evaluating shoulder instability.

  5. Can contrast-enhanced multi-detector computed tomography replace transesophageal echocardiography for the detection of thrombogenic milieu and thrombi in the left atrial appendage. A prospective study with 124 patients; Kann die kontrastmittelverstaerkte Mehrzeilen-Computertomografie die transoesophageale Echokardiografie bei der Detektion von thrombogenem Milieu und Vorhofohrthromben ersetzen? Eine prospektive Studie mit 124 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Homsi, R.; Luetkens, J.A.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Nath, B. [SHG-KLliniken Voelklingen (Germany). Dept. of Medicine I - Cardiology; Schwab, J.O. [Bonn Univ. (Germany). Dept. of Medicine I - Cardiology

    2016-01-15

    To assess the diagnostic value of contrast-enhanced multi-detector computed tomography (MD-CT) for identifying patients with left atrial appendage (LAA) thrombus or circulatory stasis. 124 patients with a history of atrial fibrillation and/or cerebral ischemia (83 men, mean age 58.6 ± 12.4 years) and with a clinical indication for MD-CT of the heart and for transesophageal echocardiography (TEE) were included in the study. LAA thrombus or thrombogenic milieu was visually identified in TEE and MD-CT. In addition, MD-CT was analyzed quantitatively measuring the Hounsfield units (HU) of the left atrium (LA), the LAA and the ascending aorta (AA), and calculating the HU ratios LAA/AA (HU [LAA/AA]) und LAA/LA (HU [LAA/LA]). Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) were calculated. The prevalence of a thrombus or thrombogenic milieu as assessed by TEE was 21.8 %. The HU ratio was lower in patients with thrombus or thrombogenic milieu (HU [LAA/AA]: 0.590 ± 0.248 vs. 0.909 ± 0.141; p < 0.001 und HU [LAA/LA] 0.689 ± 0.366 vs. 1.082 ± 0.228; p < 0.001). For the diagnosis of thrombus or a thrombogenic milieu, visual analysis yielded a sensitivity of 81.5 %, a specificity of 96.9 %, a PPV of 87.5 % and a NPV of 95.2 %. By combining visual and quantitative analysis with one criterion being positive, the specificity decreased to 91.8 %, the sensitivity to 77.8 %, the PPV to 72.4 %, and the NPV to 94.9 %. Visual analysis of the LAA in the evaluation of thrombus or thrombogenic milieu yields a high NPV of 95.1 % and may especially be useful to rule out LAA thrombi in patients with contraindications for TEE. Additional calculation of HU ratios did not improve the diagnostic performance of MD-CT.

  6. High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Korn, A.; Fenchel, M.; Bender, B.; Danz, S.; Ernemann, U. [Department of Diagnostic und Interventional Neuroradiology, Tuebingen (Germany); Thomas, C.; Ketelsen, D.; Claussen, C.D.; Heuschmid, M. [Department of Diagnostic und Interventional Radiology, Tuebingen (Germany); Moonis, G. [Beth Israel Deaconess Medical Center, Department of Radiology, Boston, MA (United States); Krauss, B. [Siemens AG, Imaging and Therapy Division, Forchheim (Germany); Brodoefel, H. [Department of Diagnostic und Interventional Radiology, Tuebingen (Germany); Beth Israel Deaconess Medical Center, Department of Radiology, Boston, MA (United States); Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA (United States)

    2013-04-15

    High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 {+-} 16.5 versus 57.3 {+-} 14.8; p = 0.50) and venous segments (15.8 {+-} 6.7 versus 18.9 {+-} 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35 % (218.2 {+-} 30 versus 141.8 {+-} 20 mGy x cm). Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis. (orig.)

  7. Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hoo Min [Dept. of Radiologic Technology, Dongnam Health College, Suwon (Korea, Republic of); Yoo, Beong Gyu [Dept. of Radiologic Technology, Wonkwang Health Science College, Iksan (Korea, Republic of); Kweon, Dae Cheol [Dept. of Radiology, Seoul National University, Seoul (Korea, Republic of)

    2008-03-15

    Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were 1.1{approx}1.8 HU, air(-998{approx}-1000 HU) and noise in the water(5.4{approx}44.8 HU), air(3.6{approx}31.4 HU). In the abdominal fat a CT attenuation coefficient(-2.2{approx}0.8 HU) and noise(10.1{approx}82.4 HU) was measured. In the abdominal was CT attenuation coefficient(53.3{approx}54.3 HU) and noise(10.4{approx}70.7 HU) in the muscle and in the liver parenchyma of CT attenuation coefficient(60.4{approx}62.2 HU) and noise (7.6{approx}63.8 HU) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  8. Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

    Energy Technology Data Exchange (ETDEWEB)

    Juergens, Kai Uwe; Maintz, David; Heimes, Britta; Fallenberg, Eva Maria; Heindel, Walter; Fischbach, Roman [University of Muenster, Department of Clinical Radiology, Muenster (Germany); Grude, Matthias [University of Muenster, Department of Cardiology and Angiology, Muenster (Germany); Boese, Jan M. [Siemens Medical Solutions, Forchheim (Germany)

    2005-01-01

    A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192{+-}24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139{+-}12, 113{+-}13 and 96{+-}11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9{+-}11.8 ml to 8.1{+-}13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function. (orig.)

  9. Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography

    Institute of Scientific and Technical Information of China (English)

    Chee Khoon LIEW; Kui Hian SIM; Rapaee ANNUAR; Tiong Kiam ONG; Sze Piaw CHIN; Tobias Seyfarth; Yean Yip FONG; Wei Ling CHAN; Choon Kiat ANG; Houng Bang LIEW

    2006-01-01

    Objectives To compare left ventricular ejection fraction (LVEF) determined from 64-row multi-detector computed tomography (64-row MDCT) with those determined from two dimensional echocardiography (2D echo) and cardiac magnetic resonance imaging (CMR). Methods Thirty-two patients with coronary artery disease underwent trans-thoracic 2D echo, CMR and contrast-enhanced 64-row MDCT for assessment of LVEF within 48 hours of each other. 64-row MDCT LVEF was derived using the Syngo Circulation software; CMR LVEF was by Area Length Ejection Fraction (ALEF) and Simpson method and 2D echo LVEF by Simpson method.Results The LVEF was 49.13 ± 15.91% by 2D echo, 50.72 ± 16.55% (ALEF method) and 47.65 ± 16.58%(Simpson method) by CMR and 50.00 ± 15.93% by 64-row MDCT. LVEF measurements by 64-row MDCT correlated well with LVEF measured with CMR using either the ALEF method (Pearson correlation r = 0.94, P <0.01) or Simpson method (r = 0.92, P<0.01). It also correlated well with LVEF measured using 2D echo (r = 0.80, P < 0.01). Conclusion LVEF measurements by 64-row MDCT correlated well with LVEF measured by CMR and 2D echo. The correlation between 64-row MDCT and CMR was better than the correlation between 2D echo with CMR. Standard data set from a 64-row MDCT coronary study can be reliably used to calculate the LVEF.

  10. Computer-aided detection of small bowel strictures in CT enterography

    Science.gov (United States)

    Sainani, Nisha I.; Näppi, Janne J.; Sahani, Dushyant V.; Yoshida, Hiroyuki

    2011-03-01

    The workflow of CT enterography in an emergency setting could be improved significantly by computer-aided detection (CAD) of small bowel strictures to enable even non-expert radiologists to detect sites of obstruction rapidly. We developed a CAD scheme to detect strictures automatically from abdominal multi-detector CT enterography image data by use of multi-scale template matching and a blob detector method. A pilot study was performed on 15 patients with 22 surgically confirmed strictures to study the effect of the CAD scheme on observer performance. The 77% sensitivity of an inexperienced radiologist assisted by CAD was comparable with the 81% sensitivity of an unaided expert radiologist (p=0.07). The use of CAD reduced the reading time to identify strictures significantly (pmuscles, or vessels, and they were easy to dismiss. The results indicate that CAD could provide radiologists with a rapid and accurate interpretation of strictures to improve workflow in an emergency setting.

  11. Computed Tomography (CT) -- Sinuses

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the ... of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly ...

  12. Iodized oil uptake assessment with cone-beam CT in chemoembolization of small hepatocellular carcinomas

    Institute of Scientific and Technical Information of China (English)

    Ung Bae Jeon; Jun Woo Lee; Ki Seok Choo; Chang Won Kim; Suk Kim; Tae Hong Lee; Yeon Joo Jeong; Dae Hwan Kang

    2009-01-01

    AIM: To evaluate the utility of assessing iodized oil uptake with cone-beam computed tomography (CT) in transarterial chemoembolization (TACE) for small hepatocellular carcinoma (HCC). METHODS: Cone-beam CT provided by a biplane flatpanel detector angiography suite was performed on eighteen patients (sixteen men and two women; 41-76 years; mean age, 58.9 years) directly after TACE for small HCC (26 nodules under 30 mm; mean diameter, 11.9 mm; range, 5-28 mm). The pre-procedural locations of the tumors were evaluated using triphasic multi-detector row helical computed tomography (MDCT). The tumor locations on MDCT and the iodized oil uptake by the tumors were analyzed on cone-beam CT and on spot image directly after the procedures. RESULTS: All lesions on preprocedural MDCT were detected using iodized oil uptake in the lesions on conebeam CT (sensitivity 100%, 26/26). Spot image depicted iodized oil uptake in 22 of the lesions (sensitivity 85%). The degree of iodized oil uptake was overestimated (9%, 2/22) or underestimated (14%, 3/22) on spot image in five nodules compared with that of cone-beam CT. CONCLUSION: Cone-beam CT is a useful and convenient tool for assessing the iodized oil uptake of small hepatic tumors (< 3 cm) directly after TACE.

  13. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, Dae Cheol [Dept. of Radiological Science, College of Health Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2016-06-15

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

  14. Detection of non-ST-elevation myocardial infarction and unstable angina in the acute setting: meta-analysis of diagnostic performance of multi-detector computed tomographic angiography

    Directory of Open Access Journals (Sweden)

    Sarno Giovanna

    2007-12-01

    Full Text Available Abstract Background Multi-detector computed tomography angiography (MDCTA has been increasingly used in the evaluation of the coronary arteries. The purpose of this study was to review the literature on the diagnostic performance of MDCTA in the acute setting, for the detection of non-ST-elevation myocardial infarction (NSTEMI and unstable angina pectoris (UAP. Methods A Pubmed and manual search of the literature published between January 2000 and June 2007 was performed. Studies were included that compared MDCTA with clinical outcome and/or CA in patients with acute chest pain, presenting at the emergency department. More specifically, studies that only included patients with initially negative cardiac enzymes suspected of having NSTEMI or UAP were included. Summary estimates of diagnostic odds ratio (DOR, sensitivity and specificity, negative (NLR and positive likelihood ratio (PLR were calculated on a patient basis. Random-effects models and summary receiver operating curve (SROC analysis were used to assess the diagnostic performance of MDCTA with 4 detectors or more. The proportion of non assessable scans (NAP on MDCTA was also evaluated. In addition, the influence of study characteristics of each study on diagnostic performance and NAP was investigated with multivariable logistic regression. Results Nine studies totalling 566 patients, were included in the meta-analysis: one randomised trial and eight prospective cohort studies. Five studies on 64-detector MDCTA and 4 studies on MDCTA with less than 64 detectors were included (32 detectors n = 1, 16 detectors n = 2, 16 and 4 detectors n = 1. Pooled DOR was 131.81 (95%CI, 50.90–341.31. The pooled sensitivity and specificity were 0.95 (95%CI, 0.90–0.98 and 0.90 (95%CI, 0.87–0.93. The pooled NLR and PLR were 0.12 (95%CI, 0.06–0.21 and 8,60 (95%CI, 5.03–14,69. The results of the logistic regressions showed that none of the investigated variables had influence on the diagnostic

  15. Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies

    Institute of Scientific and Technical Information of China (English)

    Maythem; Saeed; Steven; W; Hetts; Robert; Jablonowski; Mark; W; Wilson

    2014-01-01

    Myocardial pathologies are major causes of morbidity and mortality worldwide. Early detection of loss of cellular integrity and expansion in extracellular volume(ECV) in myocardium is critical to initiate effective treatment. The three compartments in healthy myocardium are: intravascular(approximately 10% of tissue volume), interstitium(approximately 15%) and intracellular(approximately 75%). Myocardial cells, fibroblasts and vascular endothelial/smooth muscle cells represent intracellular compartment and the main proteins in the interstitium are types Ⅰ/Ⅲ collagens. Microscopic studies have shown that expansion of ECV is an important feature of diffuse physiologic fibrosis(e.g., aging and obesity) and pathologic fibrosis [heart failure, aortic valve disease, hypertrophic cardiomyopathy, myocarditis, dilated cardiomyopathy, amyloidosis, congenital heart disease, aortic stenosis, restrictive cardiomyopathy(hypereosinophilic and idiopathic types), arrythmogenic right ventricular dysplasia and hypertension]. This review addresses recent advances in measuring of ECV in ischemic and non-ischemic myocardial pathologies. Magnetic resonance imaging(MRI) has the ability to characterize tissue proton relaxation times(T1, T2, and T2*). Proton relaxation times reflect the physical and chemical environments of water protons in myocardium. Delayed contrast enhanced-MRI(DE-MRI) and multi-detector computed tomography(DE-MDCT) demonstrated hyper-enhanced infarct, hypo-enhanced microvascular obstruction zone and moderately enhanced peri-infarct zone, but are limited for visualizing diffuse fibrosis and patchy microinfarct despite the increase in ECV. ECV can be measured on equilibrium contrast enhanced MRI/MDCT and MRI longitudinal relaxation time mapping. Equilibrium contrast enhanced MRI/MDCT and MRI T1 mapping is currently used, but at a lower scale, as an alternative to invasive sub-endomyocardial biopsies to eliminate the need for anesthesia, coronary catheterization and

  16. High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Karlo, Christoph; Leschka, Sebastian; Goetti, Robert Paul; Feuchtner, Gudrun; Desbiolles, Lotus; Stolzmann, Paul; Marincek, Borut; Baumueller, Stephan [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Plass, Andre; Falk, Volkmar [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Group, Boston, MA (United States)

    2011-01-15

    To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. 120 patients(mean age 68 {+-} 13 years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. Interobserver agreement was good({kappa} = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 {+-} 0.3 mSv) were significantly lower compared to group C(17.5 {+-} 4.4 mSv; p < 0.01). High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisition. (orig.)

  17. Epstein-Barr Virus-Associated Lymphoepithelioma-Like Gastric Carcinoma Presenting as a Submucosal Mass: CT Findings with Pathologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Won; Shin, Hyeong Cheol; Kim, Il Young; Kim, Chang Jin; Lee, Ji Hye; Lee, Chang Kyun; Jeong, Dong Jun [Soonchunhyang University Cheonan Hospital, Cheonan(Korea, Republic of)

    2010-12-15

    A lymphoepithelioma-like carcinoma, characterized by a carcinoma with heavy lymphocyte infiltration, is one of the histological patterns observed in patients with Epstein-Barr virus (EBV)-associated gastric carcinoma. Less than half of invasive carcinomas with lymphoepithelioma-like histology can grow to make a submucosal mass. These tumors generally have a better prognosis than conventional adenocarcinomas. We report a case of an EBV-associated lymphoepitheliomalike gastric carcinoma that presented as a submucosal mass on multi-detector (MD) CT and correlate them with the pathology

  18. The Value and Reason in CT Diagnosis of Transient Hepatic Perfusion Disorders in Patients with Hepatic Abscess%肝脓肿不同时相一过性灌注的 CT 表现及原因探讨

    Institute of Scientific and Technical Information of China (English)

    孙瑜

    2014-01-01

    目的:探讨肝脓肿CT 三期增强检查中伴发的异常灌注(THPD)征象的表现及产生机制。方法:回顾性分析27例经临床证实、CT 增强显示 T HPD征象的图像资料,对不同时相出现 T HPD病例的CT 表现、原因及其发生机制进行分析。结果:CT 增强显示动脉期17例高灌注 T HPD ,2例同时有高灌注和低灌注 T HPD两种表现,1例单纯低灌注 T HPD ;门脉期表现为高灌注 T HPD 者3例,单纯低灌注 T HPD 者4例。结论:动脉期T HPD有助于肝脓肿诊断,T HPD表现多样,与其产生机制多种、病程长短有关。%Objective:ToevaluatethetriphasicMSCTfeaturesoftransienthepaticperfusiondisorders (THPD)inpatientswithhepaticabscessand explore its main mechanism .Methods :Analyze the pre-contrast and dynamic contrast scan T HPD feature of 27 hepatic abscess patients (12 male ,15 female ,age ranging from 40 to 83 ,mean 60 .7 ± 11 .9 years) who were scaned by a 128 -slice MSCT scanner and confirmed by clinical .Results :Hyper-perfusion THPD in 17 patients ,hyper -and hypo -perfusion THPD in 2 patients ,and hypo -perfusion THPD in 1 patient were shown on arterial phase scans .Others were only shown on portal venous phase scans ,including hyper -perfusion THPD in 3 patients ,and hypo -perfusion THPD in 4 patients .Conclusion:The THPD accompanied with hepatic abscess shows various features ,which may be caused by different pathogenic mechanisms and courses of disease .

  19. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose; CT-Angiographie der Koronarien mit prospektivem EKG-Triggering. Hohe diagnostische Genauigkeit bei niedriger Strahlendosis

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldi, E. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Klinikum der Ludwigs-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Ramos-Duran, L.; Abro, J.A.; Costello, P. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Zwerner, P.L.; Schoepf, U.J. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Medical University of South Carolina, Charleston, Department of Medicine, Division of Cardiology, Charleston (United States); Nikolaou, K.; Reiser, M.F. [Klinikum der Ludwigs-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2010-06-15

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses ({>=}50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6{+-}1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [German] Ziel unserer Untersuchungen war es, die CT-Angiographie der Koronarien (Koronar-CTA) unter Verwendung des prospektiven EKG-Triggerings (PT) hinsichtlich ihrer diagnostischen Genauigkeit zur Detektion signifikanter Koronarstenosen mit der Herzkatheteruntersuchung (HK) zu vergleichen. Bei 20 Patienten wurden eine Koronar-CTA mit PT an einem 128-Zeilen-CT-Scanner (Definition trademark, AS+, Siemens) und eine HK durchgefuehrt. Alle CTA-Studien wurden von 2 Radiologen bzgl. signifikanter Koronarstenosen ({>=}50% Lumeneinengung) anhand des 15-Segment-Modells der American Heart Association (AHA) im Konsensus ausgewertet. Die Ergebnisse der CTA wurden mit den Befunden der HK verglichen. Die Koronar-CTA mit PT zeigte fuer die Diagnose signifikanter Stenosen im Vergleich zur HK eine Sensitivitaet von 88 bzw. 100%, eine Spezifitaet

  20. Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Kost, Susan D.; Carver, Diana E.; Stabin, Michael G. [Vanderbilt University, Physics and Astronomy Department, Nashville, TN (United States); Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Fraser, Nicholas D.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States)

    2015-11-15

    Organ dose is essential for accurate estimates of patient dose from CT. To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest-abdomen-pelvis CT and investigate how these relate to patient size. We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F = 21:19; range 0.6-17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDI{sub vol})-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. We found that CTDI{sub vol}-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R{sup 2} > 0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R{sup 2} = 0.95). Our results agreed with previous studies within 12% using similar scan parameters (e.g., bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDI{sub vol} prior to CT examination. This information provides an improved method for patient dose estimation. (orig.)

  1. National Survey of Radiation Dose and Image Quality in Adult CT Head Scans in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chung-Jung Lin

    Full Text Available The purpose of the present study was to evaluate the influence of different variables on radiation dose and image quality based on a national database.Taiwan's Ministry of Health and Welfare requested all radiology departments to complete a questionnaire for each of their CT scanners. Information gathered included all scanning parameters for CT head scans. For the present analysis, CT machines were divided into three subgroups: single slice CT (Group A; multi-detector CT (MDCT with 2-64 slices (Group B; and MDCT with more than 64 slices (Group C. Correlations between computed tomography dose index (CTDI and signal-to-noise ratio (SNR with cumulated tube rotation number (CTW(n and cumulated tube rotation time (CTW(s, and sub group analyses of CTDI and SNR across the three groups were performed.CTDI values demonstrated a weak correlation (r = 0.33 with CTW(n in Group A. SNR values demonstrated a weak negative correlation (r = -0.46 with CTW(n in Group C. MDCT with higher slice numbers used more tube potential resulting in higher effective doses. There were both significantly lower CTDI and SNR values in helical mode than in axial mode in Group B, but not Group C.CTW(n and CTW(s did not influence radiation output. Helical mode is more often used in MDCT and results in both lower CTDI and SNR compared to axial mode in MDCT with less than 64 slices.

  2. Multi-detector computed tomography radiation doses in the follow-up of paediatric neurosurgery patients in KwaZulu-Natal: A dosimetric audit

    Directory of Open Access Journals (Sweden)

    Christopher T. Sikwila

    2014-05-01

    Full Text Available Background: Multi-detector computed tomography (MDCT is the preferred modality for follow-up of paediatric neurosurgery patients. Serial imaging, however, has the disadvantage of an ionising radiation burden, which may be mitigated using the ‘as low as reasonably achievable’ (ALARA principle. Objectives: The primary objectives were to determine the radiation dose exposure in paediatric patients subjected to MDCT imaging following neurosurgery and to compare these values with references in current literature. Our secondary objective was to assess the relationship between radiation dose and clinical scenario. Method: Retrospective descriptive data were collected from all paediatric postsurgical patients (n = 169 between the ages of 0 and 12 years who had their first followed-up scan in the year 2010 and were followed up for six months or less. Dose-length product (DLP and current-time product were collected from the picture archiving and communication system. Demographic data including radiology reports were collected from the hospital information system. The effective doses (ED were calculated from the corresponding DLP using age-adjusted conversion factors. For purposes of comparison with other studies, median dosimetric values were calculated and the children were grouped into three age ranges, namely younger than 3 years, 3–7 years and 8–12 years old. Results: The highest median radiation doses were noted in patients being followed-up for intracranial abscesses (1183 mGy cm in the 8–12 year age group, most of whom were female. The lowest radiation doses were for intracranial shunt follow-ups (447 mGy cm. Median values for DLP, ED and current-time product (mAs were comparable to reference doses in all three age groups. However, our study showed a much broader distribution of values with higher upper limits relative to reference values. Indications for follow-up included shunts (n = 110; 65%, intracranial abscess (n = 31; 18%, subdural

  3. Study of superdeformation in {sup 151,152}Tb isotopes using Eurogam multi-detector; Etude de la superdeformation dans les isotopes {sup 151,152}Tb a l`aide du multidetecteur Eurogam

    Energy Technology Data Exchange (ETDEWEB)

    Kharraja, E.B.

    1994-06-01

    The aim of this work is the study of {sup 151}Tb and {sup 152}Tb nuclei submitted to increasing speeds using the EUROGAM (phase I) multi-detector. The production of high angular momentum excited nuclei is obtained during {sup 130}Te({sup 27}Al,xn) fusion-evaporation reaction with a 154 MeV bombardment energy. For {sup 151}Tb nucleus, the diagram of high spin normal deformation levels is first determined to allow the analysis of bonds between SD structures and normally deformed states. In addition to the two SD bands already described for {sup 151}Tb nucleus, 8 new SD bands are described (6 for {sup 151}Tb nucleus and 2 for {sup 152}Tb nucleus) using triple and quadruple events analysis. The SD structure analysis gives important informations about nuclear superdeformation in this mass region, in particular about SD bands de-excitation, intrinsic configuration in the second potential well, and gamma transition energy degeneration between twin SD bands. A detailed description of EUROGAM 4{pi}{gamma} multi-detector (phase I and II), which comprises 42 Ge detectors with Compton suppression, is given. (J.S.). 98 refs., 100 figs., 22 tabs.

  4. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  5. Optimizing CT for the evaluation of vestibular aqueduct enlargement:Inter-rater reproducibility and predictive value of reformatted CT measurements

    Institute of Scientific and Technical Information of China (English)

    Misun Hwang; Ryan Marovich; Samuel S. Shin; David Chi; Barton F. Branstetter IV

    2015-01-01

    Enlarged vestibular aqueduct (EVA), the most frequent identifiable cause of congenital hearing loss, is evaluated with high-definition multi-detector CT in the axial plane. Our purpose was to determine which reformatted CT measurements are most reproducible. Seven multiplanar reformatted images were created for each of the 64 temporal bones in patients with EVA. Intraclass correlation coefficients (ICC) were used to assess inter-observer variability, and both linear regression and ROC analyses were used to compare the measurements with severity of hearing loss, as assessed by pure tone audiometry. All seven measurements had excellent inter-observer variability, with average-measure ICC ranging from 0.92 to 0.98. There was no statistically significant correlation between the radiologic degree of aqueduct enlargement and severity of hearing loss using any of the seven measurements;ROC analyses revealed areas under the curves ranging from 0.57 to 0.73. Optimal accuracy was obtained with a threshold of 1.75 mm as measured at the aqueductal aperture in the P€oschl plane, with sensitivity of 0.75 and specificity of 0.63. Although the radiologic measurement may not serve as a reliable tool for assessing severity of EVA, P€oschl plane reformatting has proven to be better than conventional axial acquisition plane for identifying patients with clinically significant hearing loss.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ... after the procedure? CT exams are generally painless, fast and easy. With multidetector CT, the amount of ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and accurate. A ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an implanted medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate ...

  9. Abdominal and Pelvic CT

    Science.gov (United States)

    ... Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen ... and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a ...

  10. Assessment of the efficacy of the education of radiographers who interpret CT-colonography examinations

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl; Jeppesen, Lau; Westphal, Lena

    2014-01-01

    ‐center trial reported excellent sensitivity for large adenomas and cancers.17 A further study by Kim et al., compared the diagnostic yield from parallel OC and CTC screening programs and found similar detection rates of advanced neoplasia in the two groups.18 Some studies have documented wide inter...... the possibilities for assigning tasks to less educated personnel groups such as radiographers.21 Until now, most research has focused on the technical capabilities of CTC; however, it is increasingly being realized that reader experience and training are equally important.22 In terms of how teaching cases......) display techniques. The examination was first introduced in 1994 by Vinning,11 and since the introduction there have been further advancements in CTC technology. Multi detector CT now permits image acquisition of thin 1‐ to 2‐mm slices of the entire large intestine, well within breath‐hold imaging times...

  11. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  12. Evaluation of CT Angiography in the Diagnosis of Renal Artery Fiber Muscular Dysplasia%肾动脉纤维肌性发育不良的CTA诊断价值

    Institute of Scientific and Technical Information of China (English)

    曹茂盛; 黄卫华; 陈爱华; 尚斌

    2014-01-01

    Objective To evaluate multi-slice spiral CT angiography (MSCTA) in diagnosing renal artery fibromuscular dysplasia (RAFMD).Methods A total of 16 patients with surgically-or DSA-proved RAFMD were enrolled in this study.All patients received 64-row 128-slice spiral CT angiography.The clinical data and imaging manifestations,focusing on the lesion' s location,degree of stenosis and secondary changes,were retrospectively analyzed.Results Of the 16 cases,RAFMD occurred in the right renal artery in 8,in the left renal artery in4,and in the bilateral renal arteries in 4.In 14 cases the lesion was located at the middle-distal segment of renal artery,and in two cases the lesion was located at the proximal segment of renal artery.In 12 cases,the middle-distal segment of renal artery took the form of string-of-beads,with the diameter of bead being larger than the normal arterial lurnen in 10 and less than the normal arteriallumen in 2.Long segment smooth stenosis of the renal artery lumen was seen in 2 cases,and localized concentric stenosis was observed in other two cases.RAFMD associated with aneurysm formation was found in 8 cases and with arterial dissection in one case.Renal infarction caused by RAFMD was observed in one case.RAFMD complicated by superior mesenteric artery fibromuscular dysplasia was seen in 2 cases.Conclusion The 64-row 128-slice spiral CT angiography can distinctly display the various pathological changes of renal artery fibromuscular dysplasia.Therefore,CT angiography should be the imaging examination of first choice for the diagnosis of RAFMD.%目的 探讨多层螺旋CT血管成像(MSCTA)对肾动脉纤维肌性发育不良(RAFMD)的诊断价值.方法 回顾性研究经手术或数字减影血管造影(DSA)确认的RAFMD 16例CTA表现并分析其病变部位、狭窄程度及继发改变等.结果 16例RAFMD中单独发生于右肾动脉8例,单独发生于左肾动脉4例,双侧肾动脉均发生4例.14例发生于肾动脉中远段,2例发生

  13. Detection of Small Hepatocellular Carcinoma with Multi- detector Row CT:Effect of Iodine Concentration of Contrast Material%多排螺旋CT增强扫描对比剂浓度对小肝癌检出率的影响

    Institute of Scientific and Technical Information of China (English)

    田洪梓

    2012-01-01

      目的:通过多排螺旋CT动脉期及门脉期增强扫描,以评估对比剂浓度对小肝癌(≤3cm)检出率的影响.方法:95例肝癌患者随机分为2组行多排螺旋CT肝脏平扫及动脉期、门脉期增强扫描,其中1组(48例)注射碘帕醇370mg I/ml(1.5ml/kg),另外1组(47例)注射碘帕醇300mg I/ml(1.85ml/kg),均于30秒注射完毕.扫描后图像由放射科医生阅片并与病理结果进行对比,统计分析2组≤3cm的肝癌病灶的诊断敏感性.结果:95例患者中共证实有259个肝癌病灶,其中101个≤3cm.对于≤3cm的病灶动脉期370mg I/ml组诊断敏感性高于300mg I/ml组,差别有统计学意义;在门脉期2组病人的诊断敏感性无显著性差异.结论:高浓密度对比剂在动脉期可提高小肝癌(≤3cm)的检出率.%  Objective:To evaluate the effect of iodine concentration of contrast material on detection of small hepatocellular carcinoma (SHCC) with multi-detector row CT by using arterial phase and portal venous phase enhanced scanning.Methods:Ninety-five patients with HCC were examined by hepatic plain CT and contrast-enhanced CT including arterial phase (AP) and hepatic parenchymal phase (HPP) scanning prospectively. Patients were randomized into two groups to receive Iopamidol 370 mg I/ml (48 patients) (1.5 ml/kg body weight) and 300 mg I/ml (47 patients) (1.85 ml/kg body weight) respectively with a fixed injection duration of 30 seconds. The images were interpreted by radiologists and the CT results were compared with the pathological results. The detection sensitivity for small tumors (≤3 cm) and iodine concentration groups were calculated and analyzed.Results:A total of 259 lesions were detected with 101 ≤3 cm in size. For AP, the sensitivity of Iopamidol 370 mg I/ml group was significantly higher than Iopamidol 300 mg I/ml. For HPP, there were no significant differences between groups. Conclusions:High iodine concentration contrast material

  14. A STUDY ON DIAGNOSTIC ACCURACY OF BIOCHEMICAL MARKERS AND TRANS–ABDOMINAL ULTRASONOGRAPHY IN COMPARISON TO MULTI-DETECTOR COMPUTED TOMOGRAPHY IN DETECTION OF ACUTE PANCREATITIS

    Directory of Open Access Journals (Sweden)

    Biplab Debbarma

    2016-07-01

    Full Text Available Acute pancreatitis is an acute, mainly diffuse, inflammatory process of the pancreas. Computed Tomography (CT scan is the modality of choice for diagnosis of acute pancreatitis. But non-availability of Computed Tomography (CT scan in all health facilities made detection of acute pancreatitis is problemsome. OBJECTIVES 1. To assess the diagnostic accuracy of Biochemical Markers and Trans-Abdominal Ultrasonography in comparison to Multidetector Computed Tomography in diagnosis of acute pancreatitis. 2. To compare the findings of Trans-Abdominal Ultrasonography with Multidetector Computed Tomography. MATERIALS AND METHODS 100 clinically suspected for acute pancreatitis patients were tested for abnormal biochemical markers, followed by examined by USG and then by MDCT in Radiodiagnosis Department of AGMC and GBP Hospital and findings were compared. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. RESULTS The sensitivity and specificity of trans-abdominal ultrasonography was calculated as 75% (CI 64.06% - 84.01% and 100% (CI 83.16%-100%. CONCLUSION USG had similar sensitivity, but higher specificity value than serum markers (Amylase and Lipase.

  15. Giant Choledochal Cyst Mimicking Massive Gallbladder Hydrops in an Adult Patient: Multi Detector Computed Tomography and Magnetic Resonance Imaging Findings Correlated to Gross and Histopathological Findings

    Directory of Open Access Journals (Sweden)

    Joon-Il Choi

    2013-01-01

    Full Text Available Choledochal cysts are uncommon congenital anomalies of the biliary tree, commonly presenting in infancy, generally in the 1 st year of life. Presentation in adult life is less common, accounting for 20% of cases. A 19-year-old female patient presented to the Emergency Department with severe abdominal distension, a palpable abdominal mass, mild jaundice and low grade fever. Ultrasound, computed tomography (CT and magnetic resonance imaging of the abdomen showed a massive septated cystic lesion filling the entire abdomen with a significant mass effect on surrounding structures. Origin of the lesion was unclear and diagnosis included a giant mesenteric or duplication cyst, massive gallbladder with hydrops, biliary cystadenoma and giant choledochal cyst, among others. Final diagnosis was a Type IA choledochal cyst with massive asymmetric cystic dilatation of the extra-hepatic segments of the left hepatic duct with asymmetric dilatation of the right hepatic duct. Patient had an uneventful recovery after resection of the entire extrahepatic cyst and Roux-en-Y hepaticojejunostomy at the level of the hilum. In this article, we correlate CT and MRI findings to gross and histopathological findings of this giant Todani′s Type IA choledochal cyst.

  16. 多层螺旋CT不同重建技术在口腔颌面正畸中的对比研究%Comparison of different reconstruction techniques of multi-detector CT in dentofacial orthodontic

    Institute of Scientific and Technical Information of China (English)

    张雅萍; 赵振华; 王伯胤; 张国兴; 徐利军; 钱伟永

    2010-01-01

    目的:探讨多层螺旋CT不同重建技术在口腔颌面正畸中的应用及价值.材料与方法:对30例口腔颌面正畸病例行MIP、VR、SSD及MPR后处理,观察几种不同图像显示的效果,结果:SSD、MIP、VR 3种三维重建方法图像的清晰度、锐利度、细节显示、伪影等方面统计学上无显著性差异(P>0.05).VR重建方法在立体显示方面优于SSD法及MIP法,MPR的牙齿轴位、冠状位、矢状位重建,在显示解剖细节上具有优势.结论:多层螺旋CT不同重建技术在口腔颌面畸彤的分析测量中各有优势,VR结合MPR对口腔颌面畸形的诊断、数据的测量最佳.

  17. MDCT定量评价腔内血栓形成的腹主动脉瘤瘤体弹性%Quantitative Assessment of Abdominal Aortic Aneurysm Sac Distensibility with Intraluminal Thrombus Using Multi-Detector CT

    Institute of Scientific and Technical Information of China (English)

    李莉丽; 查云飞; 李亮; 彭宙峰; 陆雪松

    2013-01-01

    Objective To noninvasively and quantitatively evaluate the distensibility of abdominal aortic aneurysm sac(AAAs) with intraluminal thrombus using 64 MDCT.Methods 31 patients with AAAs underwent computed tomography angiography (CTA)examination.Time resolved images were acquired with the retrospective ECG-gated technology and section data acquisition mode.Scan data were reconstructed at 20 phases between 0% and 95% of the R-R intervals with an increment of 5%.All reconstructed images were analyzed using algorithm developed Matlab 7.5 (Version R2007b,the MathWorks,Natick,MA,USA).At different phases,AAA sac diameter,max and minimal area,distensibility values were calculated in the lumen and wall.Results Aneurysm sac diameter had not any correlation with distensibility(rwall =-0.315,rlumen =-0.251,Pwall,lumen > 0.05).Mean distensibility of Dlumen and Dwall were (1.15 ± 0.47) ×10-5Pa-1 and (0.95 ± 0.48) × 10-5 pa-1,respectively.A significant difference of distensibility between AAA wall and AAA lumen was proved (P < 0.05) also by use of the Wilcoxon test.Distensibility of the AAA wall was significantly lower than that of AAA lumen.Conclusion AAA distensibility is completely independent of the aneurysm size,and the distensibility of lumen is significantly higher than that of wall.Distensibility assessment could be a valuble method for the diagnosis and treatment for abdominal aortic aneurysm.%目的 探讨64排CT定量评价腔内血栓腹主动脉瘤瘤体弹性.方法 对31例含腔内血栓腹主动脉瘤患者采用回顾性心电门控技术和分段数据采集方式行腹主动脉64排螺旋CT血管成像.将获得的原始数据在0%~ 95% R-R间期,间隔5%分别重组图像,采用MATLAB 7.5软件行半自动图像分割方法,然后分别测量各期相内瘤体直径、最大和最小面积及弹性D值等指标在管腔及管壁方面的变化.结果 腹主动脉瘤瘤体最大直径与管壁、管腔弹性值间均无显著相关性(r分别为-0.315、-0.251,P均>0.05).瘤体管腔弹性D值为(1.15 ±0.47)×10-5Pa-1,管壁弹性D值为(0.95±0.48)×10-5Pa-1,瘤体管腔D值明显高于管壁,差异具有统计学意义(P<0.05).结论 腔内血栓形成的腹主动脉瘤瘤体弹性的大小并不依赖于瘤体直径的变化,且瘤体管腔的弹性要明显高于管壁.弹性评估可以为腹主动脉瘤的诊断和治疗提供帮助.

  18. Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Frauenfelder, Thomas; Appenzeller, Philippe; Karlo, Christoph; Scheffel, Hans; Desbiolles, Lotus; Stolzmann, Paul; Marincek, Borut; Alkadhi, Hatem; Schertler, Thomas [University Hospital Zurich, Department of Medical Radiology, Institute of Diagnostic Radiology, Zurich (Switzerland)

    2009-04-15

    Triage decisions in patients suffering from acute chest pain remain a challenge. The patient's history, initial cardiac enzyme levels, or initial electrocardiograms (ECG) often do not allow selecting the patients in whom further tests are needed. Numerous vascular and non-vascular chest problems, such as pulmonary embolism (PE), aortic dissection, or acute coronary syndrome, as well as pulmonary, pleural, or osseous lesions, must be taken into account. Nowadays, contrast-enhanced multi-detector-row computed tomography (CT) has replaced previous invasive diagnostic procedures and currently represents the imaging modality of choice when the clinical suspicion of PE or acute aortic syndrome is raised. At the same time, CT is capable of detecting a multitude of non-vascular causes of acute chest pain, such as pneumonia, pericarditis, or fractures. Recent technical advances in CT technology have also shown great advantages for non-invasive imaging of the coronary arteries. In patients with acute chest pain, the optimization of triage decisions and cost-effectiveness using cardiac CT in the emergency department have been repetitively demonstrated. Triple rule-out CT denominates an ECG-gated protocol that allows for the depiction of the pulmonary arteries, thoracic aorta, and coronary arteries within a single examination. This can be accomplished through the use of a dedicated contrast media administration regimen resulting in a simultaneous attenuation of the three vessel territories. This review is intended to demonstrate CT parameters and contrast media administration protocols for performing a triple rule-out CT and discusses radiation dose issues pertinent to the protocol. Typical life-threatening and non-life-threatening diseases causing acute chest pain are illustrated. (orig.)

  19. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system

    Energy Technology Data Exchange (ETDEWEB)

    Demehri, S. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Johns Hopkins Outpatient Center, JHOC 5168, Musculoskeletal Radiology, Baltimore, MD (United States); Muhit, A.; Zbijewski, W.; Stayman, J.W. [Johns Hopkins University, Department of Biomedical Engineering, Baltimore, MD (United States); Yorkston, J.; Packard, N.; Senn, R.; Yang, D.; Foos, D. [Carestream Health, Rochester, NY (United States); Thawait, G.K.; Fayad, L.M.; Chhabra, A.; Carrino, J.A. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Siewerdsen, J.H. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Johns Hopkins University, Department of Biomedical Engineering, Baltimore, MD (United States)

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80kVp-108mAs for CBCT; 120kVp- 300mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated ''excellent'' or ''good'' (median scores 5 and 4) for ''bone'' and ''soft tissue'' visualization tasks. Hand CBCT images were rated ''excellent'' or ''adequate'' (median scores 5 and 3) for ''bone'' and ''soft tissue'' visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ∝ 0.26-0.92), and interobserver agreement was fair to moderate (κ ∝ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. (orig.)

  20. Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art.

    Science.gov (United States)

    Stradiotti, P; Curti, A; Castellazzi, G; Zerbi, A

    2009-06-01

    The projectional nature of radiogram limits its amount of information about the instrumented spine. MRI and CT imaging can be more helpful, using cross-sectional view. However, the presence of metal-related artifacts at both conventional CT and MRI imaging can obscure relevant anatomy and disease. We reviewed the literature about overcoming artifacts from metallic orthopaedic implants at high-field strength MRI imaging and multi-detector CT. The evolution of multichannel CT has made available new techniques that can help minimizing the severe beam-hardening artifacts. The presence of artifacts at CT from metal hardware is related to image reconstruction algorithm (filter), tube current (in mA), X-ray kilovolt peak, pitch, hardware composition, geometry (shape), and location. MRI imaging has been used safely in patients with orthopaedic metallic implants because most of these implants do not have ferromagnetic properties and have been fixed into position. However, on MRI imaging metallic implants may produce geometric distortion, the so-called susceptibility artifact. In conclusion, although 140 kV and high milliamperage second exposures are recommended for imaging patients with hardware, caution should always be exercised, particularly in children, young adults, and patients undergoing multiple examinations. MRI artifacts can be minimized by positioning optimally and correctly the examined anatomy part with metallic implants in the magnet and by choosing fast spin-echo sequences, and in some cases also STIR sequences, with an anterior to posterior frequency-encoding direction and the smallest voxel size.

  1. MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?

    Energy Technology Data Exchange (ETDEWEB)

    Li, X [Cleveland State University, Cleveland, OH (United States); Morgan, A; Davros, W [Cleveland State University, Cleveland, OH (United States); Cleveland Clinic, Cleveland, Ohio (United States); Dong, F [Cleveland Clinic, Cleveland, Ohio (United States); Primak, A [Siemens Medical Solutions USA, Inc. (United States); Segars, W [Duke University, Durham, NC (United States)

    2014-06-15

    Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash, Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup

  2. Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, Jessen; Khan, M. Fawad; Maataoui, Adel; Herzog, C.; Vogl, Thomas J. [Johann Wolfgang Goethe University, Institute for Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Bux, R.; Bratzke, H. [Johann Wolfgang Goethe University, Institute for Forensic Medicine, Frankfurt am Main (Germany); Ackermann, Hanns [Johann Wolfgang Goethe University, Institute for Epidemiology and Medical Statistics, Frankfurt am Main (Germany)

    2005-09-01

    To optimize examination protocols of 16-row multi-detector CT (MDCT) of pelvis for dose reduction with regard to image quality. MDCT of pelvis was performed on 12 cadaver specimens with stepwise reduction of tube current from 160 mA (113, 80, 56, 40, 28) to 20 mA at 120 kV. Scan parameters were 16 x 1.5 mm collimation. Reconstructions of axial and coronal images were used for evaluation of cortex, trabeculum, image quality, image noise, acetabulum and iliosacral (ISJ) joints. After data were blinded, evaluation of images was done by three radiologists according to 5-point Likert scale. Accuracy of the observers in sorting films according to dose reduction was determined with kappa coefficient. Mean values of image evaluation were determined. Pronounced deterioration of image quality for all criteria was observed between 80 and 28 mA. Adequate image quality was obtained at 40 mA [effective dose (E): 2.2 mSv, CTDI{sub w}: 2.8 mGy] for criterion detailed definition of acetabulum and ISJ and at 80 mA (E: 4.4 mSv, CTDI{sub w}: 5.6 mGy) for remaining criteria. Moderate agreement was observed between the three observers (kappa coefficient: 0.31). All observers were excellent in arranging images according to decreasing dose. Using 16-row MDCT image quality of pelvis is acceptable at 80 mA and 120 kV. This translates into a dose reduction of 33% of average value of the nationwide survey of the German Roentgen Society (1999) for this type of examination. (orig.)

  3. Automated characterization of normal and pathologic lung tissue by topological texture analysis of multidetector CT

    Science.gov (United States)

    Boehm, H. F.; Fink, C.; Becker, C.; Reiser, M.

    2007-03-01

    Reliable and accurate methods for objective quantitative assessment of parenchymal alterations in the lung are necessary for diagnosis, treatment and follow-up of pulmonary diseases. Two major types of alterations are pulmonary emphysema and fibrosis, emphysema being characterized by abnormal enlargement of the air spaces distal to the terminal, nonrespiratory bronchiole, accompanied by destructive changes of the alveolar walls. The main characteristic of fibrosis is coursening of the interstitial fibers and compaction of the pulmonary tissue. With the ability to display anatomy free from superimposing structures and greater visual clarity, Multi-Detector-CT has shown to be more sensitive than the chest radiograph in identifying alterations of lung parenchyma. In automated evaluation of pulmonary CT-scans, quantitative image processing techniques are applied for objective evaluation of the data. A number of methods have been proposed in the past, most of which utilize simple densitometric tissue features based on the mean X-ray attenuation coefficients expressed in terms of Hounsfield Units [HU]. Due to partial volume effects, most of the density-based methodologies tend to fail, namely in cases, where emphysema and fibrosis occur within narrow spatial limits. In this study, we propose a methodology based upon the topological assessment of graylevel distribution in the 3D image data of lung tissue which provides a way of improving quantitative CT evaluation. Results are compared to the more established density-based methods.

  4. Morphometrical dimensions of the sheep thoracolumbar vertebrae as seen on digitised CT images.

    Science.gov (United States)

    Mageed, Mahmoud; Berner, Dagmar; Jülke, Henriette; Hohaus, Christian; Brehm, Walter; Gerlach, Kerstin

    2013-09-01

    The sheep spine is widely used as a model for preclinical research in human medicine to test new spinal implants and surgical procedures. Therefore, precise morphometric data are needed. The present study aimed to provide computed tomographic (CT) morphometry of sheep thoracolumbar spine. Five adult normal Merino sheep were included in this study. Sheep were anaesthetised and positioned in sternal recumbency. Subsequently, transverse and sagittal images were obtained using a multi-detector-row helical CT scanner. Measurements of the vertebral bodies, pedicles, intervertebral disc and transverse processes were performed with dedicated software. Vertebral bodies and the spinal canal were wider than they were deep, most obviously in the lumbar vertebrae. The intervertebral discs were as much as 57.4% thicker in the lumbar than in the thoracic spine. The pedicles were higher and longer than they were wide over the entire thoracolumbar spine. In conclusion, the generated data can serve as a CT reference for the ovine thoracolumbar spine and may be helpful in using sheep spine as a model for human spinal research.

  5. Cardiac CT Scan

    Science.gov (United States)

    ... combine these pictures to create a three-dimensional (3D) model of the whole heart. This imaging test ... findings from earlier chest x rays. Different CT scanners are used for different purposes. A multidetector CT ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an ...

  8. Computed Tomography (CT) - Spine

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  9. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the ... images. These images can be viewed on a computer monitor, printed on film or transferred to a ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it can reveal internal injuries and ... generated during a CT scan can be reformatted in multiple planes, and can even generate three-dimensional ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  17. Gallstone ileus: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Delabrousse, E.; Bartholomot, B.; Sohm, O.; Kastler, B. [Dept. of Radiology A, CHU Jean Minjoz, University of Besancon (France); Wallerand, H. [Dept. of Surgery, CHU Jean Minjoz, University of Besancon (France)

    2000-06-01

    Gallstone ileus is a rare complication of recurrent gallstone cholecystitis. The classic radiographic triad of small bowel obstruction, pneumobilia and ectopic gallstone on abdominal plain radiograph is described with CT imaging. Because of the better resolution of CT compared with abdominal radiography and its recent accession to emergency use, radiologists should be aware of CT findings of gallstone ileus. We report a case in which gallstone ileus was initially diagnosed by CT. (orig.)

  18. CT angiography and CT perfusion in acute ischemic stroke

    NARCIS (Netherlands)

    Seeters, T. van

    2016-01-01

    CT angiography and CT perfusion are used in patients with acute ischemic stroke for diagnostic purposes and to select patients for treatment. In this thesis, the reproducibility of CT angiography and CT perfusion is examined, the additional value of CT angiography and CT perfusion for stroke outcome

  19. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  20. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Directory of Open Access Journals (Sweden)

    Marcel Koenigkam-Santos

    2013-02-01

    Full Text Available OBJECTIVE: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA in a population of severe emphysematous patients submitted to endobronchial valves (EBV implantation. MATERIALS AND METHODS: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. RESULTS: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV (mean 542 ml, reduced EBV-submitted LV (700 ml and reduced emphysema volume (331.4 ml in the positive response group, which also showed improved functional tests. CONCLUSION: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis.

  1. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  2. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans

    Science.gov (United States)

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-01

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg–Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  3. Whole spine CT for evaluation of scoliosis in children - Feasibility of sub-milli Sievert scanning protocol

    Energy Technology Data Exchange (ETDEWEB)

    Kalra, Mannudeep K. [Center for Medical Image Science and Visualization (CMIV), Linkoeping Univ., Linkoeping Univ. Hospital, Linkoeping (Sweden); Massachusetts General Hospital Imaging, Massachusetts General Hospital, Boston (United States); Quick, Petter; Persson, Anders [Center for Medical Image Science and Visualization (CMIV), Linkoeping Univ., Linkoeping Univ. Hospital, Linkoeping (Sweden)], e-mail: anders.persson@cmiv.liu.se; Singh, Sarabjeet [Massachusetts General Hospital Imaging, Massachusetts General Hospital, Boston (United States); Sandborg, Michael [Center for Medical Image Science and Visualization (CMIV), Linkoeping Univ., Linkoeping Univ. Hospital, Linkoeping (Sweden); Department of Radiophysics, Linkoeping Univ. Hospital, Linkoeping (Sweden)

    2013-03-15

    Background: Optimization of CT radiation dose is important for children due to their higher risk of radiation-induced adverse effects. Anatomical structures with high inherent contrast, such as bones can be imaged at very low radiation doses by optimizing scan parameters. Purpose: To assess feasibility of sub-milli Sievert whole spine CT scanning protocol for evaluation of scoliosis in children. Material and Methods: With approval of the ethical board, we performed whole spine CT for evaluation of scoliosis in 22 children (age range, 3-18 years; mean age, 13 years; 13 girls, 9 boys) on a 128-slice dual source multidetector-row CT scanner. Lowest possible quality reference mAs value (image quality factor for xy-z automatic exposure control or xyz-AEC, CARE Dose 4D) was selected on a per patient basis. Remaining parameters were held constant at 3.0:1 pitch, 128 X 0.6 mm detector collimation, 115.2 mm table feed per gantry rotation, 100 kVp, and 1 and 3 mm reconstructed sections. Average mAs, projected estimated dose savings with AEC, computed tomography dose index volume (CTDI vol), and dose length product (DLP) were recorded. Artifacts were graded on a four-point scale (1, no artifacts; 4, severe artifacts). Ability to identify vertebral and pedicular contours, and measure pedicular width and degree of vertebral rotation was graded on a three-point scale (1, unacceptable; 3, excellent). Results: All CT examinations were deemed as reliable for identifying vertebral and pedicular contours as well as for measuring pedicular width (5.9 {+-} 1.6 mm) and degree of vertebral rotation (28.7{+-} 23.4 deg). Mean objective image noise and signal to noise ratio (SNR) were 57.5 {+-} 21.5 {+-} 4.7 2.3, respectively. With a mean quality reference mAs of 13, the scanner employed an average actual effective mAs of 10 {+-} 3.8 (range, 6-18 mAs) with an estimated radiation dose saving of 43.5 {+-} 16.3% with xyz-AEC compared with fixed mAs. The mean CTDI, DLP, and estimated effective

  4. Emphasis on CT examination of mesenteric ischemia disease%重视肠系膜缺血疾病的 CT 检查

    Institute of Scientific and Technical Information of China (English)

    孙钢

    2015-01-01

    [Absrt act] Mesenteric ischemia is a complicated disorder which severely intimidates the lives of patients,and the prevalence is increasing as the population ages.The key to successful treatment is early diagnosis.With the introduction of multi-detector row computed tomography(CT)and three-dimensional(3D) imaging,it is now possible to perform a detailed CT examination of the small bowel and mesenteric vessels and improve the diagnosis ability of mesenteric ischemia.CT demonstrates intestinal wall abnormalities that can be analyzed by categorizing attenuation changes in the intestinal wall.These attenuation patterns include white,gray,water halo sign,fat halo sign and black.The specific of the patterns combing with morphologic observations may aid to identify various CT enhancement patterns of diseased bowel wall.%肠系膜缺血是一个严重威胁患者生命的疾病,随着人口老龄化,其发病率也有所增加,该病救治成功的关键在于早期明确诊断。随着多排螺旋CT的临床应用及后处理技术的不断完善,提高了肠系膜缺血的早期诊断能力。 CT显示的肠壁异常可根据衰减模式进行分类,衰减模式分类包括白色、灰色、水晕征、脂肪晕征、黑色。具体衰减模式结合形态学观察有助于CT检查对肠道疾病的鉴别诊断。

  5. Evaluation on the feasibility of assessment of volume perfusion for the whole lung by multi-slice spiral CT%应用多层螺旋CT对全肺容积灌注评价的可行性研究

    Institute of Scientific and Technical Information of China (English)

    孙海涛; 朱小飞; 张霞; 谢元忠; 柳澄

    2015-01-01

    Objective The aim of this study was to evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion.Methods Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (5 patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, with calculation of pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) generated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and compared made between the normal and abnormal lung groups, not with standing a few lungs in big size beyond the coverage of 20.7 cm.Results Regional PBF, PBV, and MTT demonstrated significant differences in the gravitational and was ogravitational directions in the normal lung group (P20.7 cm的覆盖范围,但是在肺实质正常组和肺实质异常组间动态容积灌注CT的PBF和PBV均存在统计学差异(P<0.05).结论 应用128层螺旋CT定量及可视化定性评价全肺动态容积灌注具有可行性,对于全肺的形态和功能学特征仅用一种检查就能进行全面评价.

  6. Analysis of multi-slice spiral CT images in patients with esophageal cancer after surgery or radiotherapy%食管癌患者术后或放疗后多排螺旋 CT 影像分析

    Institute of Scientific and Technical Information of China (English)

    王锋

    2016-01-01

    Objective To explore the application value of multi-detector row spiral CT after the operation or radiotherapy in patients with esophageal carcinoma .Methods From August 2014 to March 2015,23 patients with esophageal cancer treated in our hospital received the examination of multi-detector row spiral CT after the operation or radiotherapy .Results After operation,CT re-sults showed that there were 4 cases with postoperative lymph node metastasis ,2 with lung metastasis and 3 with bone metastases ,2 with pericardial effusion ,1 with pleural effusion ,1 with esophageal mediastinum fistula and 1 with anastomotic recurrence .CT results also showed that after radiotherapy there were 12 with lymph node metastasis ,2 with liver metastasis ,3 with lung metastasis ,1 with radioac-tive pneumonia and 2 with pleural effusion .Conclusion The multi-slice helical CT can display a number of clinical manifestations such as complications ,recurrence and metastasis after operation and radiotherapy .It has an important clinical value .%目的:探讨多排螺旋CT在食管癌患者术后或放疗中的应用价值。方法2014年8月至2015年3月我院收治的23例食管癌患者,术后或放疗后均行多部位多排螺旋CT检查。结果 CT结果显示:术后患者出现淋巴结转移4例,肺部转移2例,骨转移3例,心包积液2例,胸腔积液1例,食管纵膈瘘1例,吻合口复发1例;而放疗后患者出现淋巴结转移12例,肝脏转移2例,肺部转移3例,放射性肺炎1例,胸腔积液2例。结论多排螺旋CT可显示出食管癌患者术后或放疗后的并发症、复发及转移等临床表现,具有重要的临床应用价值。

  7. Gamma multi-detectors and nuclear structure studies: search for superdeformed structures in {sup 147}Gd and {sup 144}Gd isotopes using Crystal Castle; simulation calculations for EUROGAM multi-detector definition; Multidetecteurs gamma et etudes de structure nucleaire: recherche avec le Chateau de Cristal de structures superdeformees dans les isotopes {sup 147}Gd et {sup 144}Gd; calculs de simulation pour la definition du multidetecteur EUROGAM

    Energy Technology Data Exchange (ETDEWEB)

    France, G. de

    1991-12-31

    Computer simulations have been used for the calculation of the new generation of 4 {pi}{gamma} multi-detectors (Castle Crystal) of EUROGAM system (phase I and II). Two superdeformed bands (I and II), comprising 16 and 13 transitions respectively, have been described for {sup 147}Gd nucleus during the {sup 122}Sn({sup 30}Si,5n) fusion-evaporation reaction in a 155 MeV bombardment energy. Dynamic inertia momentum similarities and gamma transition energy similarities have been observed between band I and {sup 148}Gd nucleus and between band II and {sup 146}Gd nucleus, respectively. These similarities can be related to a pseudo-spin symmetry. Calculations suggest the existence of an octupolar susceptibility in this mass region. {sup 144}Gd nucleus has been studied using {sup 120}Sn({sup 29}Si,5n) fusion-evaporation reaction in a 155 MeV bombardment energy and using {sup 100}Mo({sup 48}Ti,4n) reactions in a 200 MeV bombardment energy. {gamma}-{gamma} coincidences have revealed the existence of a 58 keV width valley in the matrix representation compatible with theoretical predictions. In spite of the evidence for about ten transitions during these experiments, no superdeformed structure has been demonstrated for {sup 144}Gd nucleus. (J.S.). 87 refs., 57 figs., 41 tabs.

  8. PET/CT Artifacts

    OpenAIRE

    Blodgett, Todd M.; Mehta, Ajeet S.; Mehta, Amar S.; Laymon, Charles M; Carney, Jonathan; Townsend, David W.

    2011-01-01

    There are several artifacts encountered in PET/CT imaging, including attenuation correction (AC) artifacts associated with using CT for attenuation correction. Several artifacts can mimic a 2-deoxy-2-[18F] fluoro-D-glucose (FDG) avid malignant lesions and therefore recognition of these artifacts is clinically relevant. Our goal was to identify and characterize these artifacts and also discuss some protocol variables that may affect image quality in PET/CT.

  9. The effect of CT scanner parameters and 3D volume rendering techniques on the accuracy of linear, angular, and volumetric measurements of the mandible

    Science.gov (United States)

    Whyms, B.J.; Vorperian, H.K.; Gentry, L.R.; Schimek, E.M.; Bersu, E.T.; Chung, M.K.

    2013-01-01

    Objectives This study investigates the effect of scanning parameters on the accuracy of measurements from three-dimensional multi-detector computed tomography (3D-CT) mandible renderings. A broader range of acceptable parameters can increase the availability of CT studies for retrospective analysis. Study Design Three human mandibles and a phantom object were scanned using 18 combinations of slice thickness, field of view, and reconstruction algorithm and three different threshold-based segmentations. Measurements of 3D-CT models and specimens were compared. Results Linear and angular measurements were accurate, irrespective of scanner parameters or rendering technique. Volume measurements were accurate with a slice thickness of 1.25 mm, but not 2.5 mm. Surface area measurements were consistently inflated. Conclusions Linear, angular and volumetric measurements of mandible 3D-CT models can be confidently obtained from a range of parameters and rendering techniques. Slice thickness is the primary factor affecting volume measurements. These findings should also apply to 3D rendering using cone-beam-CT. PMID:23601224

  10. Evaluation of Enteroneovesical Fistula by 64-Detector CT Enterography: A Case Report

    Science.gov (United States)

    Algin, Oktay; Metin, Melike Rusen; Karaoglanoglu, Mustafa

    2015-01-01

    Enterovesical fistula is an abnormal communication between the bladder and the intestine. The accurate localization of leakage is important for accurate treatment planning. Some imaging techniques can not demonstrate the fistula; therefore, choosing the appropriate imaging technique is necessary. CT enterography (CTE) is a new technique for evaluation of the small bowel and the entire abdomen. CTE examination with multi-detector CT (MDCT) enables us to get excellent quality reformatted images with high spatial resolution. We report a patient with neobladder and enteroneovesical fistula. We showed the exact location of the fistula and its’ association with the bowels and neobladder by CTE. The aim of this report is to show that CTE can be a new and effective modality in the detection of enteroneovesical fistulas and to discuss the efficacy of CTE in the detection and evaluation of enterovesical fistula referring to the literature. In conclusion, CTE may be a useful, sensitive, effective, and non-invasive technique for the evaluation of enteroneovesical fistula, leakage from the anastomose sides, and other extraintestinal complications such as urinary tract obstruction or abscess formation. PMID:26060558

  11. The measurement of position of retromandibular vein with multi-detector row helical CTA in relation to the mandibular angle plasty.%下颌角手术相关颌后静脉走行的CTA研究

    Institute of Scientific and Technical Information of China (English)

    王燕; 华泽权; 刘文元; 李树华

    2012-01-01

    目的:应用CTA(血管造影术)影像测量颌后静脉与下颌角手术相关解剖,为避免手术中损伤颌后静脉提供指导.方法:选择30名正常成人下颌角及周围血管CTA扫描图像,应用ADW4.2图像处理软件测量颌后静脉距下颌角处颌骨各边缘的三维解剖位置.结果:颌后静脉距下颌角点的距离为(11.26±2.34) mm;在下颌角点上10 mm处距下颌骨后缘为(8.18±2.12) mm;在下颌角点上20 mm处距下颌骨后缘为(6.38±2.12) mm;在下颌角点上30 mm处距下颌骨后缘为(3.18±2.12) mm,在下颌角点上40 mm处距下颌骨后缘为(2.18±1.16) mm.结论:在下颌骨后缘手术时位置越高颌后静脉距下颌骨越近,手术越容易损伤颌后静脉;参照测量获得的解剖数据在下颌角成型手术中能避免损伤面前静脉及颌后静脉.%Objective: The aim of this study was to investigate the position and course of retromandibular vein using multi-detector row helical computed tomographic angiography (CTA)imaging and to relate the findings to performing the mandibular angle ptasty. Method: thirty of adulty human were selected for multi-detector row helical CTA measurement and ADW4.2 software analysis, according with a distance from the retromandibular vein to mandibular angle.at 10 mm urper the mandibular angletat 20 mm urper the mandibular angle,at 30 mm urper the mandibular angle, and at 40 mm urper the mandibular angle, retromandibular vein was examined. Result: the distance from the retromandibular vein to the mandibular angle is(11.26±2.34)mm.al 10 mm urper the mandibular angle is (8.18±2.12)mm.at 20 mm urper the mandibular angle is (6.38±2.12)mm,at 30 mm urper the mandibular angle is (3.18±2.12)mm,at 40 mm urper the mandibular angle is (2.18± 1.16)mm.Conclusion:The study is to provide further understanding of the retromandibular vein anatomy in relation to the design of the mandibuler angle plasty and to create clinical safety guidelines in order to avoid damaging

  12. Computed Tomography (CT) -- Head

    Science.gov (United States)

    ... of a stroke. a stroke, especially with a new technique called Perfusion CT. brain tumors. enlarged brain ... be asked to remove hearing aids and removable dental work. Women will be asked to remove bras ... does the equipment look like? The CT scanner is typically a ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. CT is the most reliable imaging ...

  14. CT of Gastric Emergencies.

    Science.gov (United States)

    Guniganti, Preethi; Bradenham, Courtney H; Raptis, Constantine; Menias, Christine O; Mellnick, Vincent M

    2015-01-01

    Abdominal pain, nausea, and vomiting are common presenting symptoms among adult patients seeking care in the emergency department, and, with the increased use of computed tomography (CT) to image patients with these complaints, radiologists will more frequently encounter a variety of emergent gastric pathologic conditions on CT studies. Familiarity with the CT appearance of emergent gastric conditions is important, as the clinical presentation is often nonspecific and the radiologist may be the first to recognize gastric disease as the cause of a patient's symptoms. Although endoscopy and barium fluoroscopy remain important tools for evaluating patients with suspected gastric disease in the outpatient setting, compared with CT these modalities enable less comprehensive evaluation of patients with nonspecific complaints and are less readily available in the acute setting. Endoscopy is also more invasive than CT and has greater potential risks. Although the mucosal detail of CT is relatively poor compared with barium fluoroscopy or endoscopy, CT can be used with the appropriate imaging protocols to identify inflammatory conditions of the stomach ranging from gastritis to peptic ulcer disease. In addition, CT can readily demonstrate the various complications of gastric disease, including perforation, obstruction, and hemorrhage, which may direct further clinical, endoscopic, or surgical management. We will review the normal anatomy of the stomach and discuss emergent gastric disease with a focus on the usual clinical presentation, typical imaging appearance, and differentiating features, as well as potential imaging pitfalls.

  15. Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in brain CT

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Qingguo, E-mail: renqg83@163.com [Department of Radiology, Hua Dong Hospital of Fudan University, Shanghai 200040 (China); Dewan, Sheilesh Kumar, E-mail: sheilesh_d1@hotmail.com [Department of Geriatrics, Hua Dong Hospital of Fudan University, Shanghai 200040 (China); Li, Ming, E-mail: minli77@163.com [Department of Radiology, Hua Dong Hospital of Fudan University, Shanghai 200040 (China); Li, Jianying, E-mail: Jianying.Li@med.ge.com [CT Imaging Research Center, GE Healthcare China, Beijing (China); Mao, Dingbiao, E-mail: maodingbiao74@163.com [Department of Radiology, Hua Dong Hospital of Fudan University, Shanghai 200040 (China); Wang, Zhenglei, E-mail: Williswang_doc@yahoo.com.cn [Department of Radiology, Shanghai Electricity Hospital, Shanghai 200050 (China); Hua, Yanqing, E-mail: cjr.huayanqing@vip.163.com [Department of Radiology, Hua Dong Hospital of Fudan University, Shanghai 200040 (China)

    2012-10-15

    Purpose: To compare image quality and visualization of normal structures and lesions in brain computed tomography (CT) with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP) reconstruction techniques in different X-ray tube current–time products. Materials and methods: In this IRB-approved prospective study, forty patients (nineteen men, twenty-one women; mean age 69.5 ± 11.2 years) received brain scan at different tube current–time products (300 and 200 mAs) in 64-section multi-detector CT (GE, Discovery CT750 HD). Images were reconstructed with FBP and four levels of ASIR-FBP blending. Two radiologists (please note that our hospital is renowned for its geriatric medicine department, and these two radiologists are more experienced in chronic cerebral vascular disease than in neoplastic disease, so this research did not contain cerebral tumors but as a discussion) assessed all the reconstructed images for visibility of normal structures, lesion conspicuity, image contrast and diagnostic confidence in a blinded and randomized manner. Volume CT dose index (CTDI{sub vol}) and dose-length product (DLP) were recorded. All the data were analyzed by using SPSS 13.0 statistical analysis software. Results: There was no statistically significant difference between the image qualities at 200 mAs with 50% ASIR blending technique and 300 mAs with FBP technique (p > .05). While between the image qualities at 200 mAs with FBP and 300 mAs with FBP technique a statistically significant difference (p < .05) was found. Conclusion: ASIR provided same image quality and diagnostic ability in brain imaging with greater than 30% dose reduction compared with FBP reconstruction technique.

  16. CT of tracheal agenesis

    Energy Technology Data Exchange (ETDEWEB)

    Strouse, Peter J.; Hernandez, Ramiro J. [C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Newman, Beverley [Children' s Hospital of Pittsburgh, PA (United States). Department of Pediatric Radiology; Afshani, Ehsan [Children' s Hospital of Buffalo, NY (United States). Departments of Radiology and Pediatrics; Bommaraju, Mahesh [Women' s and Children' s Hospital of Buffalo, Division of Neonatology, University Pediatrics Associates, Buffalo, NY (United States)

    2006-09-15

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an implanted medical device of any kind, unlike MRI. CT imaging provides real-time imaging, making it ...

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? CT is used to help diagnose a ... the CT examination. top of page What does the equipment look like? The CT scanner is typically ...

  19. CT scan of choristoma

    Energy Technology Data Exchange (ETDEWEB)

    Moriki, A.; Morimoto, M.; Sada, Y.; Kurisaka, M.; Mori, K.

    1987-02-01

    Choristoma is a rare tumor that occurs in the pituitary gland. The case presented here is a 44-year-old male. A plain CT scan demonstrated a slight high-density mass near the posterior clinoid of the sella turcica, while a moderate and homogeneous enhancing effect and a clear borderline were shown by an enhanced CT scan. A cornal CT scan study showed that the tumor extended from the intrasellar to the suprasellar region. The diagnosis of choristoma was made by means of histology.

  20. Deconvolution Methods for Multi-Detectors

    Science.gov (United States)

    1989-08-30

    this nonuniqueness , consider the one- I dimensional example of the Introduction. Let p and p 2 be compact supported and strongly coprime, and let v 1...i, E connected and aE Lipschitz . Then E (or f[) has the Pompelu property if and only if there is no positive eigenvalue for the overdetermined

  1. Dose reduction to the pediatric and adult as a result of spectral optimization for high-contrast abdominal CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pih Hyun; Lee, Chang Lae; Kim, Dae Hong; Kim, Hee Joung [Dept. of Radiological Science and Research Institute of Health Science, Yonsei University (Korea, Republic of)

    2012-04-15

    Improvement in multi-detector row CT (MDCT) technology now allows numerous acquisitions to be easily and rapidly performed, leading to a possibly marked increase of the dose to patients. Managing patient dose is therefore a major concern in pediatric MDCT. Dose optimization consists of obtaining the lowest acceptable image quality compatible with diagnostic purposes. It is still the radiologist's responsibility to set the appropriate CT parameters (i.e., tube potential, beam collimation, tube current-time product or AEC-quality indices) to keep the dose 'as low as reasonably achievable' for diagnostic purposes. However, while radiation dose may be precisely defined by dedicated quantities such as the CT dose index (CTDI), image quality is still difficult to objectively assess. Up until now, the 'appropriate' quality ratio was mostly defined on the basis of empirical methods. The purpose of the present study was to assess and compare various physically measurable image quality indices obtained with dedicated pediatric phantoms and CT protocols in order to more clearly understand which index should preferably be used in children to manage the dose for routine abdominal MDCT protocols, and to provide guidance on dose reduction on the basis of patient dimensions.

  2. Cervical spine CT scan

    Science.gov (United States)

    ... defects of the cervical spine Bone problems Fracture Osteoarthritis Disc herniation Risks Risks of CT scans include: ... Ma, MD, Assistant Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  4. Chest CT Scan

    Science.gov (United States)

    ... can combine these pictures to create three-dimensional (3D) models to help show the size, shape, and ... a medical imaging facility or hospital. The CT scanner is a large, tunnel-like machine that has ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ... increase the risk of an unusual adverse effect. Women should always inform their physician and the CT ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ... have diabetes —particularly if you are taking Glucophage . Women should always inform their physician and the CT ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to remove hearing aids and removable dental work. Women will be asked to remove bras containing metal ... increase the risk of an unusual adverse effect. Women should always inform their physician and the CT ...

  8. CT head in children

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Padma, E-mail: padma.rao@rch.org.au [Royal Children' s Hospital and the University of Melbourne, Medical Imaging Department, Flemington Road, Parkville, Melbourne, Victoria 3052 (Australia); Bekhit, Elhamy, E-mail: elhamy.bekhit@rch.org.au [Royal Children' s Hospital and the University of Melbourne, Medical Imaging Department, Flemington Road, Parkville, Melbourne, Victoria 3052 (Australia); Ramanauskas, Fiona, E-mail: fiona.ramanauskas@rch.org.au [Royal Children' s Hospital and the University of Melbourne, Medical Imaging Department, Flemington Road, Parkville, Melbourne, Victoria 3052 (Australia); Kumbla, Surekha, E-mail: surekha.kumbla@rch.org.au [Royal Children' s Hospital and the University of Melbourne, Medical Imaging Department, Flemington Road, Parkville, Melbourne, Victoria 3052 (Australia)

    2013-07-15

    The advances in computerized technology (CT) technique over the last few decades have greatly modified imaging protocols in children. The range of pathologies that can now be demonstrated has broadened with the advent of newer techniques such as CT perfusion and the ability to perform complex reconstructions. Increasing speed of scanning and reduction in scan time have influenced the need for sedation and general anaesthetic as well as impacting on motion artefact. Additionally, concerns about radiation safety and avoidance of unnecessary radiation have further impacted on the inclusion of CT in the imaging armamentarium. Justification and image optimisation are essential. It is important to familiarize oneself with the appearances of normal variants or age related developmental changes. CT does however remain an appropriate investigation in a number of conditions.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ... remain still during the exam. Many scanners are fast enough that children can be scanned without sedation. ...

  10. CT- and MR colonography

    DEFF Research Database (Denmark)

    Achiam, Michael Patrick; Bülow, Steffen; Rosenberg, J

    2002-01-01

    . Lately, CT- and MR colonography have emerged as non-invasive methods for colon imaging. METHODS: At present, CTC and MRC require bowel preparation. However, preliminary studies have been carried out without colon preparation. After the colon has been filled with air or contrast, the patient is scanned....... CONCLUSIONS: With the exponential development in computer processing power, CT- and MR colonography holds the promise for future colon examination with the advantages of non-invasiveness, no need for sedation, and probably no bowel preparation. A major disadvantage, however, is the radiation dose during CT...... colonography. Future developments with the use of "intelligent" computers, better resolution and faster examinations will make CT and/or MR colonography realistic options to replace conventional diagnostic colonoscopy....

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may ... particularly the lungs, abdomen, pelvis and bones. A diagnosis determined by CT scanning may eliminate the need ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... have a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may ... particularly the lungs, abdomen, pelvis and bones. A diagnosis determined by CT scanning may eliminate the need ...

  17. Lumbosacral spine CT

    Science.gov (United States)

    ... More Broken bone CT scan Cyst Herniated disk Osteoarthritis Osteomalacia Tumor Review Date 9/8/2014 Updated by: C. Benjamin Ma, MD, Assistant Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic Surgery, San Francisco, ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... contrast materials and a metallic taste in your mouth that lasts for at most a minute or ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... generated during a CT scan can be reformatted in multiple planes, and can even generate three-dimensional ... hours beforehand, as contrast material will be used in your exam. You should inform your physician of ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... or to plan radiation therapy for brain cancer. In emergency cases, it can reveal internal injuries and ... generated during a CT scan can be reformatted in multiple planes, and can even generate three-dimensional ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... is painless, noninvasive and accurate. It’s also the most reliable imaging technique for determining if the sinuses ... CT scan of the sinuses, the patient is most commonly positioned lying flat on the back. The ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Abdomen and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as ... of page What are some common uses of the procedure? This procedure is typically used to help ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... cavity. CT scanning is painless, noninvasive and accurate. It’s also the most reliable imaging technique for determining ... parts absorb the x-rays in varying degrees. It is this crucial difference in absorption that allows ...

  6. Lumbar spine CT scan

    Science.gov (United States)

    CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... your breath for short periods of time. The scan should take only 10 to 15 minutes.

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... entire body will be "inside" the scanner at one time such as with MRI. If an intravenous ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  8. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Stefan Franz [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)]. E-mail: stefan.nemec@meduniwien.ac.at; Donat, Markus Alexander [Department of Neurosurgery, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Mehrain, Sheida [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Friedrich, Klaus [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Krestan, Christian [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Matula, Christian [Department of Neurosurgery, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Imhof, Herwig [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Czerny, Christian [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)

    2007-05-15

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  9. CT- and MR colonography

    DEFF Research Database (Denmark)

    Achiam, Michael Patrick; Bülow, Steffen; Rosenberg, J

    2002-01-01

    . Lately, CT- and MR colonography have emerged as non-invasive methods for colon imaging. METHODS: At present, CTC and MRC require bowel preparation. However, preliminary studies have been carried out without colon preparation. After the colon has been filled with air or contrast, the patient is scanned...... colonography. Future developments with the use of "intelligent" computers, better resolution and faster examinations will make CT and/or MR colonography realistic options to replace conventional diagnostic colonoscopy....

  10. CT of pituitary abscess

    Energy Technology Data Exchange (ETDEWEB)

    Fong, T.C.; Johns, R.D.; Long, M.; Myles, S.T.

    1985-06-01

    Pituitary abscess is a rare condition, with only 50 cases reported in the literature. Of those, 29 cases were well documented for analysis. Preoperative diagnosis of pituitary abscess is difficult. The computed tomographic (CT) appearance of pituitary abscess was first described in 1983; the abscess was depicted by axial images with coronal reconstruction. The authors recently encountered a case of pituitary abscess documented by direct coronal CT of the sella turcica.

  11. Establishment of a semi-biological phantom model for the study of the effect of dose reducing measures on radiation-induced DNA double strand breaks in CT using the example of risk organ based tube current modulation; Etablierung eines semibiologischen Phantommodells zur Untersuchung des Effekts dosisreduzierender Massnahmen auf strahleninduzierte DNA-Doppelstrangbrueche in der CT am Beispiel der risikoorganbasierten Roehrenstrommodulation

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Matthias

    2013-12-12

    The number of computed tomography (CT) examinations has been rising during the last decades. Therefore techniques for dose reduction receive increasing attention. Risk organ-based tube current modulation (RCM) in CT is a new approach and works by lowering the tube current, while the tube is in front of the patient's body. Therefore it should lead to a dose reduction for radiosensitive organs like the female breast, the eye lenses and the thyroid gland. Biological radiation effects cannot be estimated by physical-based dose measurements. γ-H2AX is a sensitive marker for the determination of x-ray induced DNA double-strand breaks (DSB). Hence the aim of this study was to establish a biological phantom model based on the γ-H2AX immunofluorescence microscopy method and to investigate the effect of RCM on radiation induced DNA damages. The γ-H2AX method is based on the phosphorylation of the histone variant H2AX. The phosphorylated histone γ-H2AX can be visualised using antibodies and is specific for radiation induced DSB. Blood lymphocytes from healthy volunteers, skin fibroblasts (LN) and mammary epithelial cells (HMEpC-p) were placed in different positions of an Alderson-phantom and exposed to x-rays using a 128-slice dual-source CT scanner. Standard head, neck and chest-CT scan protocols either with or without risk-organ based tube current modulation were used. RCM reduces the tube current to 20 percent at an angle of 130 degree anterior to the body, whereas tube current is increased at an angle of 230 degree posterior to the body. Afterwards cells were isolated, fixed on slides und stained with specific primary γ-H2AX antibodies and fluorescent secondary antibodies. Tiny green dots (named foci) can be detected and quantified with a fluorescence microscope and represent distinct DSB. Non-irradiated samples served as controls and CT-induced DSB were calculated by subtraction of pre- from post-exposure values. In this study a semibiological phantom model

  12. Wavelet-based calculation of cerebral angiographic data from time-resolved CT perfusion acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Havla, Lukas; Dietrich, Olaf [Ludwig-Maximilians-University Hospital Munich, Josef-Lissner-Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Munich (Germany); Thierfelder, Kolja M.; Beyer, Sebastian E.; Sommer, Wieland H. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-08-15

    To evaluate a new approach for reconstructing angiographic images by application of wavelet transforms on CT perfusion data. Fifteen consecutive patients with suspected stroke were examined with a multi-detector CT acquiring 32 dynamic phases (∇t = 1.5s) of 99 slices (total slab thickness 99mm) at 80kV/200mAs. Thirty-five mL of iomeprol-350 was injected (flow rate = 4.5mL/s). Angiographic datasets were calculated after initial rigid-body motion correction using (a) temporally filtered maximum intensity projections (tMIP) and (b) the wavelet transform (Paul wavelet, order 1) of each voxel time course. The maximum of the wavelet-power-spectrum was defined as the angiographic signal intensity. The contrast-to-noise ratio (CNR) of 18 different vessel segments was quantified and two blinded readers rated the images qualitatively using 5pt Likert scales. The CNR for the wavelet angiography (501.8 ± 433.0) was significantly higher than for the tMIP approach (55.7 ± 29.7, Wilcoxon test p < 0.00001). Image quality was rated to be significantly higher (p < 0.001) for the wavelet angiography with median scores of 4/4 (reader 1/reader 2) than the tMIP (scores of 3/3). The proposed calculation approach for angiography data using temporal wavelet transforms of intracranial CT perfusion datasets provides higher vascular contrast and intrinsic removal of non-enhancing structures such as bone. (orig.)

  13. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  14. Comparison of 64-Detector CT Colonography and Conventional Colonoscopy in the Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Devir

    2016-01-01

    Full Text Available Background Colon cancer is a leading cause of morbidity and mortality in developed countries. The early detection of colorectal cancer using screening programs is important for managing early-stage colorectal cancers and polyps. Modalities that allow examination of the entire colon are conventional colonoscopy, double contrast barium enema examination and multi-detector computed tomography (MDCT colonography. Objectives To compare CT colonography and conventional colonoscopy results and to evaluate the accuracy of CT colonography for detecting colorectal lesions. Patients and Methods In a prospective study performed at Gastroenterology and Radiology Departments of Medical Faculty of Eskisehir Osmangazi University, CT colonography and colonoscopy results of 31 patients with family history of colorectal carcinoma, personal or family history of colorectal polyps, lower gastrointestinal tract bleeding, change in bowel habits, iron deficiency anemia and abdominal pain were compared. Regardless of the size, CT colonography and conventional colonoscopy findings for all the lesions were cross - tabulated and the sensitivity, specificity, and positive and negative predictive values were calculated. To assess the agreement between CT colonography and conventional colonoscopy examinations, the Kappa coefficient of agreementt was used. Statistical analysis was performed by SPSS ver 15.0. Results Regardless of the size, MDCT colonography showed 83% sensitivity and 95% specificity, with a positive predictive value of 95% and a negative predictive value of 83% for the detection of colorectal polyps and masses. MDCT colonography displayed 92% sensitivity and 95% specificity, with a positive predictive value of 92% and a negative predictive value of 95% for polyps ≥ 10 mm. For polyps between 6mm and 9 mm, MDCT colonography displayed 75% sensitivity and 100% specificity, with a positive predictive value of 100% and a negative predictive value of 90%. For polyps

  15. CT findings of fibromatoses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Nam; Choi, Yeon Hwa; Shin, Hyun Jun [Lee Rha Hospital, Chung Ju (Korea, Republic of)

    1991-03-15

    Fibromatoses constitute a group of benign fibroblastic soft tissue tumors with a tendency for local invasion and recurrence. CT provides excellent anatomic detail of soft tissue tumors and precise location, size, and extent of the tumors. The authors evaluated 7 CT scans of 6 pathologically proven aggressive fibromatoses during the last 4 years. Five lesions arose in the lower extremities: 4 in the buttocks and 1 in the thigh. One lesion arose in the upper back. The tumors were lobulated in contour and varied in size from 3.7 cm to 10.7 cm. Fibromatosis tumors were usually hypodense with muscle when no contrast medium was used and hyperdense with better delineation during infusion of the contrast medium. Three patients had recurrent disease after surgical removal. Fibromatosis may infiltrate the surrounding tissue beyond the margins, indicated on CT scans and by palpation at operation. Therefore the surgeon should plan a wide resection around the apparent limits of the fibromatosis.

  16. 双能量CT的多参数分析和临床应用%Multi-parameter Analysis of Dual-energy CT and Its Clinical Application

    Institute of Scientific and Technical Information of China (English)

    严福华; 林晓珠

    2013-01-01

    With the improvement and progress in CT technology, dual-energy CT applications became clinically available. Compared with conventional multi-detector CT, dual-energy CT technologies have realized multi-parameter imaging, including monochromatic imaging, spectral curve, basis pair for material-decomposition images in quantitative analysis and effective atomic number. The most prominent advantage of dual-energy CT is that it can not only demonstrate the morphological changing, but also provide several quantitative imaging markers reflecting the substantive characteristics of lesions. As an integrated diagnostic method, dual-energy CT technology could potentially improve the diagnosis and differentiation in the future.%随着CT技术的发展和完善,双能量CT逐步应用于临床.与常规多排CT相比,双能量CT技术实现了多参数成像,如单能量图像、能谱曲线、基物质图像及相应基物质的定量浓度值和有效原子序数.双能量CT最大的优势就是不仅能显示形态学的改变,而且可提供诸多反映病灶本质特征的量化指标.作为一个综合诊断手段,双能量CT将会在疾病的诊断和鉴别方面发挥其极大的潜力.

  17. Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies

    Science.gov (United States)

    Murase, Kenya; Nanjo, Takafumi; Satoshi, Ii; Miyazaki, Shohei; Hirata, Masaaki; Sugawara, Yoshifumi; Kudo, Masayuki; Sasaki, Kousuke; Mochizuki, Teruhito

    2005-11-01

    The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation × 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current.

  18. CT urography and hematuria

    DEFF Research Database (Denmark)

    Bretlau, Thomas; Hansen, Rasmus H; Thomsen, Henrik S

    2015-01-01

    (15%) other disease (i.e. infection or anomaly) was found. No abnormalities were found at CT urography in 455 (58%) of the patients with hematuria. Lesions were found more frequently in patients with visible hematuria than in patients with non-visible hematuria (48% vs. 29%). No malignant tumor...

  19. Hepatic angiosarcoma: CT findings

    Institute of Scientific and Technical Information of China (English)

    余日胜; 章士正; 华建明

    2003-01-01

    @@ Hepatic angiosarcoma is a rare malignant vascular tumor. Accurate preoperative diagnosis of this tumor is very difficult if the patient does not have any history of exposure to specific carcinogens including thorotrast, arsenicals and vinyl chloride monomer. We describe CT findings in two cases of hepatic angiosarcoma in combination with a review of the literature.

  20. CT image of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Morioka, Nobuo; Shudo, Yuji; Jahana, Masanobu; Matsuki, Tsutomu; Kotani, Kazuhiko (Tottori Univ., Yonago (Japan). School of Medicine)

    1983-10-01

    Computor tomographic images of 11 patients who had had thymectomy for myasthenia gravis or thymoma were studied retrospectively. Of those 11 patients, malignant thymoma and benign condition including normal thymus were 6 and 5 respectively. On CT, calcification and lobulation with irregular margin seem to be reliable findings of malignancy. Defect or abscence of fatty plane and non-homogenous density are ancillary.

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  4. Abdominal aspergillosis: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Suk Keu, E-mail: pagoda20@hanmail.net [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Hye Jin, E-mail: kimhyejin@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Byun, Jae Ho, E-mail: jhbyun@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Kim, Ah Young, E-mail: aykim@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Lee, Moon-Gyu, E-mail: mglee@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of); Ha, Hyun Kwon, E-mail: hkha@amc.seoul.kr [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1, Poongnap2-dong, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2011-03-15

    Objective: In order to retrospectively evaluate the CT findings of abdominal aspergillosis in immunocompromised patients. Materials and methods: CT scans were reviewed with regard to the sites, number, morphologic appearance, attenuation, and the contrast enhancement patterns of the lesions in six patients (5 women, 1 man; mean age, 43.4 years; range, 23-59 years) with pathologically proved abdominal aspergillosis by two gastrointestinal radiologists in consensus. Medical records were also reviewed to determine each patient's clinical status and outcome. Results: All patients were immunocompromised state: 4 patients received immunosuppressive therapy for solid organ transplantation and 2 patients received chemotherapy for acute myeloid leukemia. Aspergillosis involved blood vessels (n = 3), liver (n = 2), spleen (n = 2), gastrointestinal tract (n = 2), native kidney (n = 1), transplanted kidney (n = 1), peritoneum (n = 1), and retroperitoneum (n = 1). CT demonstrated solid organ or bowel infarction or perforation secondary to vascular thrombosis or pseudoaneurysm, multiple low-attenuating lesions of solid organs presenting as abscesses, concentric bowel wall thickening mimicking typhlitis, or diffuse or nodular infiltration of the peritoneum and retroperitoneum. Conclusion: Familiarity with findings commonly presenting as angioinvasive features or abscesses on CT, may facilitate the diagnosis of rare and fatal abdominal aspergillosis.

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? In many ways, CT scanning is like other ... sensitive to radiation, they should have a CT study only if it is essential for making a ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special x-ray equipment ... period of time. Modern CT scanners are so fast that they can scan through large sections of ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? In many ways, CT scanning is like other ... Sometimes ultrasound is substituted for CT as a method of imaging in these procedures in children. A ...

  10. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Anal Cancer Facet Joint Block Video: CT of the Heart ... Therapy Video: CT of the Sinuses Video: Colorectal Cancer Screening Radiology and You Sponsored by Image/Video ...

  11. Seventh-generation CT

    Science.gov (United States)

    Besson, G. M.

    2016-03-01

    A new dual-drum CT system architecture has been recently introduced with the potential to achieve significantly higher temporal resolution than is currently possible in medical imaging CT. The concept relies only on known technologies; in particular rotation speeds several times higher than what is possible today could be achieved leveraging typical x-ray tube designs and capabilities. However, the architecture lends itself to the development of a new arrangement of x-ray sources in a toroidal vacuum envelope containing a rotating cathode ring and a (optionally rotating) shared anode ring to potentially obtain increased individual beam power as well as increase total exposure per rotation. The new x-ray source sub-system design builds on previously described concepts and could make the provision of multiple conventional high-power cathodes in a CT system practical by distributing the anode target between the cathodes. In particular, relying on known magnetic-levitation technologies, it is in principle possible to more than double the relative speed of the electron-beam with respect to the target, thus potentially leading to significant individual beam power increases as compared to today's state-of-the-art. In one embodiment, the proposed design can be naturally leveraged by the dual-drum CT concept previously described to alleviate the problem of arranging a number of conventional rotating anode-stem x-ray tubes and power conditioners on the limited space of a CT gantry. In another embodiment, a system with three cathodes is suggested leveraging the architecture previously proposed by Franke.

  12. Technical aspects of CT scanning.

    Science.gov (United States)

    Maravilla, K R; Pastel, M S

    1978-01-01

    The advent of computed tomography (CT) has initiated a technological revolution which continues to the present time. A brief review of basic principles of CT scanning is presented, and the evolution of modern CT scanner systems is traced. Some early indications of future trends are also presented.

  13. Venous thromboembolic disease. CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, L. R. [Medical College of Wisconsin, Pulmonary Medicine and Intensive Care, Dept. of Diagnostic Radiology, Milwaukee, WI (United States)

    2001-12-01

    Helical and multidetector CT has proven to be a valuable imaging modality for both pulmonary embolism and deep venous thrombosis. This paper will review the sensitivity and specificity of CT and discuss diagnostic algorithms utilizing CT and more established imaging technologies.

  14. Dynamic CT myocardial perfusion imaging.

    Science.gov (United States)

    Caruso, Damiano; Eid, Marwen; Schoepf, U Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie; Spandorfer, Adam; Laghi, Andrea; De Cecco, Carlo N

    2016-10-01

    Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  15. CT classification of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Marincek, B.; Porcellini, B.; Robotti, G.

    1984-05-01

    The contribution of computed tomography (CT) in classifying acetabular fractures was analysed retrospectively in 33 cases. CT and plain radiography classification agreed in 27 cases (82%). CT revealed more extensive fractures in 6 patients (thereof 5 patients with associated fractures). In 10 patients (thereof 9 patients with associated fractures) CT showed intraarticular fragments; radiographically intraarticular fragments were seen only in 2 patients and suspected in 4. CT is of considerable aid in defining the fracture pattern. It should be used mainly in patients with radiographically difficult interpretable associated fractures in order to assess preoperatively the weight-bearing part of the acetabulum, the degree of displacement and the presence of intraarticular fragments.

  16. Delineation of right and left lobe of the liver accessed by 3-dimensional CT images

    Energy Technology Data Exchange (ETDEWEB)

    Teleuhan, Nadira [Hiroshima Univ. (Japan). Graduate School of Biomedical Sciences

    2003-02-01

    Adequate delineation of right and left liver lobes is very important especially in partial hepatectomy. We analyzed the sub-volumes of middle hepatic vein (MHV) draining area divided by the Cantlie's plane and MHV plane using CT 3-dimensional images. We examined 10 donor candidates for liver transplantation with multi-detector-row CT. Three-dimensional rendering images of the liver parenchyma and the hepatic vein were created. After identifying hepatic vein draining area, liver volume was divided into three hepatic vein-draining areas. The MHV draining area was divided by two different planes, Cant lie's plane and MHV plane, and draining volumes from right and left lobes were calculated. Total liver volume and right, middle, left hepatic vein-draining volume (ratio of total liver volume) were 1472{+-}259 ml, 708{+-}150 ml (48{+-}10%), 414{+-}175 ml (28{+-}12%), 350{+-}110 ml (24{+-}7%) divided by Cant lie's plane, draining volumes from right and left lobes were 306{+-}200 ml (21{+-}14%) and 108{+-}69 ml (7{+-}5%). Divided by MHV plane, draining volumes from right and left lobes were 198{+-}123 ml (13{+-}8%) and 216{+-}73 ml (15{+-}5%). Volume difference of two sub-volumes was 108{+-}92 ml (7{+-}6%, 0-270 ml). The proportion of MHV draining volume had a considerable dispersion among 10 persons. In most of cases the draining volumes from the left lobe were bigger than those from right lobes. (author)

  17. Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction

    Science.gov (United States)

    Dang, H.; Stayman, J. W.; Xu, J.; Sisniega, A.; Zbijewski, W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.

    2016-03-01

    Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.

  18. Helical CT for lumbosacral spinal

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuno, Satoshi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    1996-10-01

    The aim of this study was to investigate the efficacy of helical CT for lumbosacral pathology. We performed helical CT with multiplanar reconstruction, including the formation of oblique transaxial and coronal images, in 62 patients with various lumboscral disorders, including 32 non-enhanced CT and 36 CT after myelography. We correlated the appearance of the stenotic spinal canal and neoplastic disease with the findings on MRI obtained at nearly the same time. We obtained helical CT images in all cases in about 30 seconds. The diagnostic ability of helical CT was roughly equal to that of MRI in patients with spondylosis deformans, spondylolisthesis and herniated nucleus pulposus. There was no significant difference in diagnostic value for degenerative lumbosacral disease with canal and foraminal stenosis between non-enhanced and post-myelography helical CT. However, non-enhanced helical CT could not clearly demonstrate neoplastic disease because of the poor contrast resolution. Helical CT was useful in evaluating degenerative disorder and its diagnostic value was nearly equal to that of MRI. We considered that helical CT may be suitable for the assessment of patients with severe lumbago owing to the markedly shortened examination time. However, if helical CT is used as a screening method for lumbosacral disease, one must be careful of its limitations, for example, poor detectability of neoplastic disease, vascular anomalies and so on. (author)

  19. CT colonography: an update

    Energy Technology Data Exchange (ETDEWEB)

    Aschoff, Andrik J.; Ernst, Andrea S.; Brambs, Hans-Juergen; Juchems, Markus S. [University Hospitals of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-03-15

    Computed tomographic (CT) colonography (CTC) - also known as ''virtual colonoscopy'' - was first described more than a decade ago. As advancements in scanner technology and three-dimensional (3D) postprocessing helped develop this method to mature into a potential option in screening for colorectal cancer, the fundamentals of the examination remained the same. It is a minimally invasive, CT-based procedure that simulates conventional colonoscopy using 2D and 3D computerized reconstructions. The primary aim of CTC is the detection of colorectal polyps and carcinomas. However, studies reveal a wide performance variety in regard to polyp detection, especially for smaller polyps. This article reviews the available literature, discusses established indications as well as open issues and highlights potential future developments of CTC. (orig.)

  20. CT of pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Toshio (Nagasaki Univ. (Japan). School of Medicine)

    1990-09-01

    One hundred and two cases of acute and chronic pancreatitis were studied by computed tomography. Fluid collection was detected by CT in 45 cases, and the common extrapancreatic sites of involvement included the lesser sac (13 cases), anterior pararenal space (9 cases), transverse mesocolon (7 cases) and posterior pararenal space (5 cases). Ten cases of spontaneous resolution of pancreatic pseudocysts were encountered. Cystojejunostomy was done on 6 patients. A 4-to-6-weeks time interval has been currently accepted as necessary for pseudocyst wall maturation. However, the surgery was not possible in two patients in this series since the cyst wall was too thin. It is considered that the time over 3 months is required for surgical anastomosis of the cyst to the gastrointestinal tract. Pancreatic abscess has become the most common cause of death from pancreatitis. In this series pancreatic abscess occurred in 8 patients. Gas collection in the pancreas was observed in only one patient. In the other patients, pseudocysts had become infected and converted to abscesses. The CT number of 4 infected pseudocysts was less than 15 HU. Thus, it was not possible to distinguish infected from noninfected pseudocysts by CT. The author studied 9 patients with focal inflammatory mass of the pancreas with histologically proved severe fibrosis. All masses were small. Angiography showed occlusion or marked stenosis of the splenic vein in 3 cases. The postcontract CT (after intravenous bolus injection) in 7 cases of focal inflammatory mass demonstrated almost equal enhanced effect of the mass as compared with the adjacent normal pancreatic parenchyma. This finding is considered to be useful in distinguishing inflammatory mass from pancreatic carcinoma. (author).

  1. The Appendix on CT

    Energy Technology Data Exchange (ETDEWEB)

    Whitley, S. [Sunnybrook Health Sciences Center, Toronto, Ontario (Canada); Barts and the Royal London, Royal London Hospital, Whitechapel, London (United Kingdom)], E-mail: siobhanwhitley@yahoo.co.uk; Sookur, P.; McLean, A.; Power, N. [Barts and the Royal London, Royal London Hospital, Whitechapel, London (United Kingdom)

    2009-02-15

    Appendicitis can be a difficult clinical diagnosis to make. A negative appendicectomy rate of 20% has traditionally been accepted as the consequences of appendiceal perforation can be grave. Cross-sectional imaging is increasingly being employed in the investigation of adults with suspected appendicitis. This review will demonstrate the appearance of the normal appendix on computed tomography (CT) and its appearance in a range of inflammatory and neoplastic processes including appendicitis, Crohn's disease, infections, and benign and malignant tumour000.

  2. Spectral CT: Clinical application and research progress%能谱CT的临床应用与研究进展

    Institute of Scientific and Technical Information of China (English)

    雷立昌; 陈建宇

    2013-01-01

    多排螺旋CT技术的广泛应用及计算机后处理技术的不断发展,使能谱CT成像从理论走向实践.能谱CT从球管和探测器等方面进行革新,尽可能同时、同相位获得两个不同能量水平的图像,从而重建出40~140 keV的高清单能量图像、多种基础物质密度图像、虚拟图像以及特异能谱曲线,为疾病的早期发现、定性甚至定量诊断提供可靠依据,为临床实践和科研提供更为广阔的发展空间.%Advances in multi-detector technology and computer processing technology have made spectral CT imaging possible. On the basis of the improvement of X-ray tubes and X-ray detectors, spectral CT can obtain two images at different levels of energy at the same time and at the same phase to reconstruct high-definition and monochromatic images from 40 keV to 140 keV and even generate 3-materials decomposition images, virtual non-contrast images and specific spectrum curve. These imaging technologies provide reliable information to diagnose disease earlier and more accurately. Spectral CT is a promising technique with clinical application potential.

  3. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  4. Comparison of CT urography and intravenous urography in patients with hematuria

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Guen Young; Kang, Byung Chul; Hwang, Ji Young [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-12-15

    We wanted to compare CT urography (CTU) with using multi-detector row CT (MDCT) and intravenous urography (IVU) for diagnosing the causes of hematuria. From January 2003 to March 2004, IVU and CTU were obtained in 48 patients. We evaluated the causes of hematuria in 34 of 48 patients. The IVU images were obtained by the conventional method. The CTU images were routinely obtained before intravenous contrast injection, and at 2 and 5 minutes after intravenous contrast injection. In case of delayed excretion of contrast by the kidneys, the delayed CT scans were obtained at 120 minutes after contrast injection. All the CT images, including the axial and 3D coronal reformatted CTUs with using software as well as conventional IVU images, were reviewed by two radiologists working in consensus. We decided if urinary stone existed or not and we looked for the indirect signs such as hydronephrosis or delayed excretion, etc. We also observed if it was possible to determine the mass, ureteral stricture and enhancement of the ureteral wall, etc. We calculated sensitivity, specificity, positive predictive value and negative predictive value for each modality to diagnose urinary stone. We compared the detection rate according to the phases of CTU. We confirmed the presence of urinary tract stones in 27 of 34 patients who had undergone both IVU and CTU. We diagnosed ureteritis in 1, transitional cell carcinoma in 5 and acute pyelonephritis in 1 of the remaining 7 patients. The urinary stones were detected in fifteen patients on both IVU and CTU (15/27, 55.6%). We detected the urinary stones on CTU, but not IVU, in twelve patients (12/27, 44.5%). The sensitivity to detect the urinary stones was 100% (27/27) on CTU and 55.6% (12/27) on IVU respectively. The specificity was 100% (7/7) on IVU and CTU, respectively. The positive predictive value was 100% (15/15) on IVU and 100% (27/27) on CTU, respectively. The negative predictive value was 36.8% (7/19) on IVU and 100% (7/7) on CTU

  5. Value of Multi-Slice Spiral CT in the Diagnosis of Atypical Appendicitis%多排CT对非典型阑尾炎的诊断价值

    Institute of Scientific and Technical Information of China (English)

    李水婷; 江魁明; 麦慧; 张家云; 侍丽

    2013-01-01

    To investigate the value of the multi-detector row computed tomography in the diagnosis of appendicitis with atypical clinical feature. Methods: 58 cases of appendicitis which were not initially considered on clinical presentation, were confirmed surgically and pathologically were collected, CT characteristics were retrospectively analyzed. Results: 54 of the 58 patients were correctly diagnosed on CT. It included: 6 cases of dissect abnormal appendicitis, 22 cases of women of childbearing age appendicitis. 19 cases of elderly appendicitis. 11 cases of pediatric appendicitis. The direct CT signs of acute appendicitis were an charged appendix with wall thickening and appendicolith. Indirect signs included appendiceal perityphlitis and periappendicular. Conclusion: Multi-detector row computed tomography is valuable for early diagnosis of appendicitis with atypical clinical feature.%目的:探讨多排CT对缺乏典型临床表现的阑尾炎的应用价值.材料方法:搜集2010年1月~2012年1月临床首诊未考虑阑尾炎,经手术、病理证实为阑尾炎患者58例,回顾分析其CT表现.结果:58例阑尾炎患者中CT术前诊断为阑尾炎54例,渗断准确率93%.其中:解剖位置异常的阑尾炎6例;育龄妇女急性阑尾炎22例;老年急性阑尾炎19例;小儿急性阑尾炎11例.急性阑尾炎CT直接征象:阑尾肿胀、阑尾壁增厚及阑尾结石.CT间接征象:阑尾周围炎、阑尾周围脓肿.结论:使用多排CT对临床早期明确非典型阑尾炎的诊断有重要意义.

  6. CT protocol review and optimization.

    Science.gov (United States)

    Kofler, James M; Cody, Dianna D; Morin, Richard L

    2014-03-01

    To reduce the radiation dose associated with CT scans, much attention is focused on CT protocol review and improvement. In fact, annual protocol reviews will soon be required for ACR CT accreditation. A major challenge in the protocol review process is determining whether a current protocol is optimal and deciding what steps to take to improve it. In this paper, the authors describe methods for pinpointing deficiencies in CT protocols and provide a systematic approach for optimizing them. Emphasis is placed on a team approach, with a team consisting of at least one radiologist, one physicist, and one technologist. This core team completes a critical review of all aspects of a CT protocol and carefully evaluates proposed improvements. Changes to protocols are implemented only with consensus of the core team, with consideration of all aspects of the CT examination, including image quality, radiation dose, patient care and safety, and workflow.

  7. Methods of selection in heavy ion collisions at Fermi energies and de-excitation modes with the INDRA multi-detector; Methodes de tri dans les collisions d'ions lourds aux energies de Fermi et modes de desexcitation avec le multidetecteur INDRA

    Energy Technology Data Exchange (ETDEWEB)

    Lautesse, Ph

    2005-11-15

    The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)

  8. CT in vascular pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Bartolozzi, C.; Neri, E.; Caramella, D. [Diagnostic and Interventional Radiology Department of Oncology, University of Pisa, Via Roma 67, I-56100 Pisa (Italy)

    1998-06-02

    Since the introduction of helical scanners, CT angiography (CTA) has achieved an essential role in many vascular applications that were previously managed with conventional angiography. The performance of CTA is based on the accurate selection of collimation width, pitch, reconstruction spacing and scan delay, which must be modulated on the basis of the clinical issue. However, the major improvement of CT has been provided by the recent implementation of many post-processing techniques, such as multiplanar reformatting, shaded surface display, maximum intensity projections, 3D perspectives of surface and volume rendering, which simulate virtual intravascular endoscopy. The integration of the potentialities of the scanner and of the image processing techniques permitted improvement of: (a) the evaluation of aneurysms, dissection and vascular anomalies involving the thoracic aorta; (b) carotid artery stenosis; (c) aneurysms of abdominal aorta; (d) renal artery stenosis; (e) follow-up of renal artery stenting; and (f) acute or chronic pulmonary embolism. Our experience has shown that the assessment of arterial pathologies with CTA requires the integration of 3D post-processing techniques in most applications. (orig.) With 4 figs., 34 refs.

  9. Modern CT and PET/CT imaging of the liver; Moderne CT- und PET/CT-Bildgebung der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J.; Heusner, T.A.; Riegger, C.; Reichelt, D.; Kuhlemann, J.; Antoch, G.; Blondin, D. [Medizinische Fakultaet, Heinrich-Heine-Universitaet Duesseldorf, Institut fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2011-08-15

    Computed tomography (CT) is now widely available and represents an important and rapid method for the diagnostics of acute liver disease, characterization of focal liver lesions, planning of interventional therapy measures and postintervention control. In recent years CT has not become less important despite the increasing value of magnetic resonance imaging (MRI). By the use of different contrast medium phases good characterization of space-occupying lesions can be achieved. For the diagnostics of hepatocellular carcinoma (HCC) a triphasic examination protocol should always be implemented. The introduction of dual energy CT increased the sensitivity of imaging of hypervascularized and hypovascularized liver lesions and by the use of virtual native imaging it has become possible to avoid additional native imaging which reduces the x-ray exposition of patients. Positron emission tomography (PET) has an advantage for imaging in oncology because nearly the complete body of the patient can be screened and this is the main indication for PET/CT (whole-body staging). For purely hepatic problems 18F-fluorodeoxyglucose (FDG)-PET/CT using diagnostic CT data has a higher precision than CT alone but is inferior to MRI. (orig.) [German] Die Computertomographie (CT) ist heute breit verfuegbar und stellt eine wichtige und schnelle Methode zur Diagnostik akuter Lebererkrankungen, der Artdiagnostik fokaler Leberlaesionen und der Planung interventioneller Therapiemassnahmen sowie der postinterventionellen Kontrolle dar. In den letzten Jahren hat die CT trotz des zunehmenden Stellenwerts der Magnetresonanztomographie (MRT) nicht an Bedeutung verloren. Durch den Einsatz unterschiedlicher Kontrastmittelphasen kann meist eine gute Charakterisierung von Raumforderungen erfolgen. Bei der Diagnostik des hepatozellulaeren Karzinoms (HCC) sollte beispielsweise immer ein triphasisches Untersuchungsprotokoll angewendet werden. Mit Einfuehrung der Dual-energy-CT hat die Sensitivitaet in der

  10. Children's (Pediatric) CT (Computed Tomography)

    Science.gov (United States)

    ... not fit into the opening of a conventional CT scanner or may be over the weight limit—usually 450 pounds—for the moving table. Other imaging methods such as ultrasound or magnetic resonance (MR) imaging ... obtained by CT scanning. Working together, your primary care physician or ...

  11. Innovations in PET/CT

    DEFF Research Database (Denmark)

    Levin Klausen, T; Høgild Keller, S; Vinter Olesen, O

    2012-01-01

    There has been a longstanding interest in positron emission tomography (PET) in combination with computed tomography (CT). Mostly because of the lack of structural information in PET which makes it difficult to assess the precise location of tissue with metabolic uptake, whereas CT can provide...

  12. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  13. CT colonography. A guide for clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Mang, Thomas [Medical Univ. of Vienna (Austria). Dept. of Radiology; Schima, Wolfgang [Krankenhaus Goettlicher Heiland, Wien (Austria). Dept. of Diagnostic and Interventional Radiology; Krankenhaus der Barmherzigen Schwestern, Wien (Austria); Sankt-Josef-Krankenhaus, Wien (Austria)

    2013-07-01

    The book on CT colonography - a guide for clinical practice - covers the following issues: indications and contraindications, examination; Image interpretation; findings at CT colonography, how to generate a useful report, screening, how to train for CT colonography.

  14. Preoperative assessment of vascular anatomy of inferior mesenteric artery by volume-rendered 3D-CT for laparoscopic lymph node dissection with left colic artery preservation in lower sigmoid and rectal cancer

    Institute of Scientific and Technical Information of China (English)

    Michiya Kobayashi; Satoshi Morishita; Takehiro Okabayashi; Kana Miyatake; Ken Okamoto; Tsutomu Namikawa; Yasuhiro Ogawa; Keijiro Araki

    2006-01-01

    AIM: To determine the distance between the branching point of the left colic artery (LCA) and the inferior mesenteric artery (IMA) by computed tomography (CT) scanning, for preoperative evaluation before laparoscopic colorectal operation.METHODS: From February 2004 to May 2005, 100patients (63 men, 37 women) underwent angiography performed with a 16-scanner multi-detector row CT unit (Toshiba, Aquilion 16). All images were analyzed on a workstation (AZE Ltd, Virtual Place Advance 300). The distance from the root of the IMA to the bifurcation of the LCA was measured by curved multi-planar reconstruction on a workstation.RESULTS: The IMA could be visualized in all the cases,but the LCA was missing in two patients. The mean distance from the root of the IMA to the root of the LCA was 42.0 mm (range, 23.2-75.0 mm). There were no differences in gender, arterial branching types, body weight, height, and body mass index.CONCLUSION: Volume-rendered 3D-CT is helpful to assess the vascular branching anatomy for laparoscopic surgery.

  15. Holoprosencephaly and CT

    Energy Technology Data Exchange (ETDEWEB)

    Asada, M.; Tamaki, N.; Ebara, K.; Shirakuni, T.; Yamashita, H. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    Holoprosencephaly, so termed by DeMyer, is a cerebral malformation in which the prosencephalon fails to divide into cerebral hemispheres early in fetal life. According to the degree of division in the prosencephalon and the presence of the associated facial anomalies, he classified holoprosencephaly into three types; alobar, semilobar, and lobar. We have had experience with six cases with holoprosencephaly: one alobar, one semilobar, and four lobar. No significant facial abnormalities were found in any case, but one had hyperterolism. All cases had hydrocephalus and had undergone an operation for a ventriculo-peritoneal shunt. The outcome of the shunt operation in two cases with alobar and semilobar holoprosencephaly was miserable. On the other hand, the cases with lobar type showed a fairly good prognosis. They were only mildly mentally retarded on a follow-up examination. It seemed, therefore, that the ventriculo-peritoneal shunt is indicated for this lobar type of holoprosencephaly. For this reason, it is important to make a precise diagnosis before any shunt operation. CT is a useful and safe diagnostic procedure for evaluating the intracranial structures of holoprosencephaly: the degree of division in the prosencephalon, the ventricular configuration, the dorsal sac, and the absence of falx. When the hydrocephalus associated with this disease is severe, the interhemispheric fissure is not clearly delineated, and it may sometimes be difficult to differentiate the semilobar from the lobar type of holoprosencephaly. The course of the azygos anterior cerebral artery on angiograms is useful in distinguishing one from the other. It is hoped that a multi-directional approach on CT will reveal a more precise structure of holoprosencephaly and that a definitive diagnosis can be made without angiography or other invasive procedures.

  16. Thoracic textilomas: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Dianne Melo; Zanetti, Glaucia; Araujo Neto, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Silva, Jorge Luiz Pereira e; Guimaraes, Marcos Duarte; Escuissato, Dante Luiz; Souza Junior, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Hospital Universitario Antonio Pedro (HUAP/UFF), Niteroi, RJ (Brazil)

    2014-09-15

    Objective: the aim of this study was to analyze chest CT scans of patients with thoracic textiloma. Methods: this was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. Results: the majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). Conclusions: it is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. (author)

  17. SPECT-CT and PET-CT progress in the research of computer analysis method

    Directory of Open Access Journals (Sweden)

    Jingang Guo

    2015-04-01

    Full Text Available The development of multimodal imaging equipment is milestone in the development of imaging, after the PET-CT, American GE company launched a Discovery 670 NM/CT, CT and SPECT, the organic integration of the formation of SPECT-CT new molecular medical imaging equipment, with SPECT, CT and PET-CT is getting more and more widely attention and application, many of SPECT-CT and PET-CT image analysis computer method arises at the historic moment, getting increasing attention of the clinical and imaging science. The paper carried on the detailed description of the SPECT-CT and PET-CT computer analysis method.

  18. A novel method of estimating effective dose from the point dose method: a case study—parathyroid CT scans

    Science.gov (United States)

    Januzis, Natalie; Nguyen, Giao; Hoang, Jenny K.; Lowry, Carolyn; Yoshizumi, Terry T.

    2015-02-01

    The purpose of this study was to validate a novel approach of applying a partial volume correction factor (PVCF) using a limited number of MOSFET detectors in the effective dose (E) calculation. The results of the proposed PVCF method were compared to the results from both the point dose (PD) method and a commercial CT dose estimation software (CT-Expo). To measure organ doses, an adult female anthropomorphic phantom was loaded with 20 MOSFET detectors and was scanned using the non-contrast and 2 phase contrast-enhanced parathyroid imaging protocols on a 64-slice multi-detector computed tomography scanner. E was computed by three methods: the PD method, the PVCF method, and the CT-Expo method. The E (in mSv) for the PD method, the PVCF method, and CT-Expo method was 2.6  ±  0.2, 1.3  ±  0.1, and 1.1 for the non-contrast scan, 21.9  ±  0.4, 13.9  ±  0.2, and 14.6 for the 1st phase of the contrast-enhanced scan, and 15.5  ±  0.3, 9.8  ±  0.1, and 10.4 for the 2nd phase of the contrast-enhanced scan, respectively. The E with the PD method differed from the PVCF method by 66.7% for the non-contrast scan, by 44.9% and by 45.5% respectively for the 1st and 2nd phases of the contrast-enhanced scan. The E with PVCF was comparable to the results from the CT-Expo method with percent differences of 15.8%, 5.0%, and 6.3% for the non-contrast scan and the 1st and 2nd phases of the contrast-enhanced scan, respectively. To conclude, the PVCF method estimated E within 16% difference as compared to 50-70% in the PD method. In addition, the results demonstrate that E can be estimated accurately from a limited number of detectors.

  19. Role of multi-detector computed tomography (MDCT in management of post percutaneous nephrolithotomy (PCNL bleeding [v1; ref status: indexed, http://f1000r.es/205

    Directory of Open Access Journals (Sweden)

    Arvind P Ganpule

    2013-11-01

    Full Text Available Objective: To evaluate the role of multidetector computerized tomography (MDCT angiography in post percutaneous nephrolithotomy (PCNL bleed and compare findings with conventional angiography (CA. Material and methods: We conducted a retrospective analysis of patients who had post PCNL bleeding and subsequently underwent a MDCT angiography followed by CA. We reviewed eight patients, who presented between January 2009 and January 2013. We performed a MDCT angiography on a 16 slice GE bright speed CT scanner. All angiographies were done by using the Digital Subtraction Angiography Suite. The angioembolisation, if required, was conducted by an interventional nephrologist, specializing in therapeutic embolisation. Results: The mean age of the patients was 42±17 years. Mean time of post PCNL bleed presentation was 10.06±7.9 days. Five patients presented with aneurysm and three presented with an AV fistula with pseudoaneurysm. The right renal unit was involved in six cases and the left in two cases. The lower polar segmental artery was involved in six cases and the upper polar artery in two cases. The CA and MDCT findings matched in all cases and the MDCT helped the clinician to assess and embolise the appropriate arterial tree. Conclusion: MDCT is rapid, reproducible and noninvasive. MDCT angiography performed in the setting of post PCNL bleeding provides an accurate assessment of the site and nature of bleeding. The MDCT angiography matched the CA findings in all patients in the present study.

  20. CT of thoracic aortic aneurysms.

    Science.gov (United States)

    Posniak, H V; Olson, M C; Demos, T C; Benjoya, R A; Marsan, R E

    1990-09-01

    Aneurysms of the thoracic aorta are most often the result of arteriosclerotic disease. Other causes include degeneration of the medial layer of the aortic wall, either idiopathically or due to genetic disorders such as Marfan syndrome; aortic dissection; trauma; syphilis and other bacterial infection; noninfective aortitis; and congenital anomaly. We review normal anatomy of the aorta and discuss our technique and interpretation of computed tomography (CT) in the evaluation of the thoracic aorta. We illustrate the CT appearance of different types of aortic aneurysms as well as discuss the use of CT for assessing complications of aneurysms, for postoperative follow-up, and in the differentiation of aortic aneurysm from a paraaortic mass.

  1. CT findings of colonic diverticulitis

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Shigeru; Ohba, Satoru [Nagoya City Univ. (Japan). Medical School; Mizutani, Masaru [and others

    1998-11-01

    Although colonic diverticulitis has no indication for operation, but in some mistaken cases were operated with a diagnosis of acute appendicitis. We evaluated the CT findings of colonic diverticulitis about 19 cases and of asymptomatic colonic diverticula about 15 cases retrospectively. Diagnosis was confirmed of barium enema and operation. CT are complementary methods of examination that can delineated the range of thickening of the colon and the extension of inflammatory changes around the colon. We also believe that CT findings of colonic diverticulitis are useful for differentiating from a diagnosis of appendicitis. (author)

  2. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  3. CT volumetry of lumbar vertebral bodies in patients with hypoplasia L5 and bilateral spondylolysis and in normal controls

    Energy Technology Data Exchange (ETDEWEB)

    Wilms, Guido E.; Demaerel, Philippe; Keyzer, Frederik de [UZ Leuven, Campus Gasthuisberg, Department of Radiology, Leuven (Belgium); Willems, Endry [ZOL, Department of Radiology, Genk (Belgium)

    2012-08-15

    To examine the feasibility and results of calculating the volume of lumbar vertebral bodies in normal patients and patients with suspected hypoplasia of L5. Lumbar multi-detector CT was performed in 38 patients with bilateral spondylolysis and hypoplasia of L5 and in 38 normal patients. Lumbar vertebral body volume of L3, L4 and L5 was measured by CT volumetry with a semi-automated program, created with MeVisLab. In the control group, the average vertebral body volume (in cubic centimeters) of L3 was 35.93 ({+-}7.33), 36.34 ({+-}7.13) for L4 and 34.63 ({+-}6.88) for L5. In patients with suspected hypoplasia L5 the average body volume (in cubic centimeters) of L3 was 36.85 ({+-}7.37), 36.90 ({+-}6.99) for L4 and 33.14 ({+-}6.57) for L5. The difference in mean vertebral body volume for L3, L4 and L5 between both groups was statistically not significant. However, there was a statistically significant difference of the ratio L5/L4 (P < 0.001) between both groups: the mean ratio L5/L4 in the control group was 95.3 {+-} 3.9%, the ratio for the hypoplastic L5 group was 89.9 {+-} 6.3%. There was no significant difference in the vertebral body volume for L3, L4 and L5 between both groups due to inter-patient variability. However, the relation between the body volume of L5 and L4 is significantly different between both groups. The volume of the vertebral body of L5 proved to be on average 10.2% smaller than the volume of L4 in the group with hypoplasia L5 versus 4.7% in the control group. (orig.)

  4. Evaluation of patient dose using a virtual CT scanner: Applications to 4DCT simulation and Kilovoltage cone-beam imaging

    Science.gov (United States)

    DeMarco, J. J.; McNitt-Gray, M. F.; Cagnon, C. H.; Angel, E.; Agazaryan, N.; Zankl, M.

    2008-02-01

    This work evaluates the effects of patient size on radiation dose from simulation imaging studies such as four-dimensional computed tomography (4DCT) and kilovoltage cone-beam computed tomography (kV-CBCT). 4DCT studies are scans that include temporal information, frequently incorporating highly over-sampled imaging series necessary for retrospective sorting as a function of respiratory phase. This type of imaging study can result in a significant dose increase to the patient due to the slower table speed as compared with a conventional axial or helical scan protocol. Kilovoltage cone-beam imaging is a relatively new imaging technique that requires an on-board kilovoltage x-ray tube and a flat-panel detector. Instead of porting individual reference fields, the kV tube and flat-panel detector are rotated about the patient producing a cone-beam CT data set (kV-CBCT). To perform these investigations, we used Monte Carlo simulation methods with detailed models of adult patients and virtual source models of multidetector computed tomography (MDCT) scanners. The GSF family of three-dimensional, voxelized patient models, were implemented as input files using the Monte Carlo code MCNPX. The adult patient models represent a range of patient sizes and have all radiosensitive organs previously identified and segmented. Simulated 4DCT scans of each voxelized patient model were performed using a multi-detector CT source model that includes scanner specific spectra, bow-tie filtration, and helical source path. Standard MCNPX tally functions were applied to each model to estimate absolute organ dose based upon an air-kerma normalization measurement for nominal scanner operating parameters.

  5. Size-based emphysema cluster analysis on low attenuation area in 3D volumetric CT: comparison with pulmonary functional test

    Science.gov (United States)

    Lee, Minho; Kim, Namkug; Lee, Sang Min; Seo, Joon Beom; Oh, Sang Young

    2015-03-01

    To quantify low attenuation area (LAA) of emphysematous regions according to cluster size in 3D volumetric CT data of chronic obstructive pulmonary disease (COPD) patients and to compare these indices with their pulmonary functional test (PFT). Sixty patients with COPD were scanned by a more than 16-multi detector row CT scanner (Siemens Sensation 16 and 64) within 0.75mm collimation. Based on these LAA masks, a length scale analysis to estimate each emphysema LAA's size was performed as follows. At first, Gaussian low pass filter from 30mm to 1mm kernel size with 1mm interval on the mask was performed from large to small size, iteratively. Centroid voxels resistant to the each filter were selected and dilated by the size of the kernel, which was regarded as the specific size emphysema mask. The slopes of area and number of size based LAA (slope of semi-log plot) were analyzed and compared with PFT. PFT parameters including DLco, FEV1, and FEV1/FVC were significantly (all p-value< 0.002) correlated with the slopes (r-values; -0.73, 0.54, 0.69, respectively) and EI (r-values; -0.84, -0.60, -0.68, respectively). In addition, the D independently contributed regression for FEV1 and FEV1/FVC (adjust R sq. of regression study: EI only, 0.70, 0.45; EI and D, 0.71, 0.51, respectively). By the size based LAA segmentation and analysis, we evaluated the Ds of area, number, and distribution of size based LAA, which would be independent factors for predictor of PFT parameters.

  6. Errors in CT colonography.

    Science.gov (United States)

    Trilisky, Igor; Ward, Emily; Dachman, Abraham H

    2015-10-01

    CT colonography (CTC) is a colorectal cancer screening modality which is becoming more widely implemented and has shown polyp detection rates comparable to those of optical colonoscopy. CTC has the potential to improve population screening rates due to its minimal invasiveness, no sedation requirement, potential for reduced cathartic examination, faster patient throughput, and cost-effectiveness. Proper implementation of a CTC screening program requires careful attention to numerous factors, including patient preparation prior to the examination, the technical aspects of image acquisition, and post-processing of the acquired data. A CTC workstation with dedicated software is required with integrated CTC-specific display features. Many workstations include computer-aided detection software which is designed to decrease errors of detection by detecting and displaying polyp-candidates to the reader for evaluation. There are several pitfalls which may result in false-negative and false-positive reader interpretation. We present an overview of the potential errors in CTC and a systematic approach to avoid them.

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices ... the need for sedation and general anesthesia. New technologies that will make even faster scanning possible are ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanner is typically a large machine with a hole, or short tunnel, in the center. A moveable ... up in shades of gray and air appears black. With CT scanning, numerous x-ray beams and ...

  10. Multiplanar CT of the spine

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, S.L.G.; Glenn, W.V. Jr.

    1986-01-01

    This is an illustrated text on computed tomography (CT) of the lumbar spine with an emphasis on the role and value of multiplanar imaging for helping determine diagnoses. The book has adequate discussion of scanning techniques for the different regions, interpretations of various abnormalities, degenerative disk disease, and different diagnoses. There is a 50-page chapter on detailed sectional anatomy of the spine and useful chapters on the postoperative spine and the planning and performing of spinal surgery with CT multiplanar reconstruction. There are comprehensive chapters on spinal tumors and trauma. The final two chapters of the book are devoted to CT image processing using digital networks and CT applications of medical computer graphics.

  11. CT Perfusion of the Head

    Science.gov (United States)

    ... physicians diagnose and treat medical conditions. CT scanning combines special x-ray equipment with sophisticated computers to ... The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is a history of heart disease, asthma, diabetes, kidney disease or thyroid problems. Any of these conditions may ... of imaging in these procedures in children. A diagnosis determined by CT scanning may eliminate the need ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... through the body, recording an image on photographic film or a special image recording plate . Bones appear ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like ... materials and a metallic taste in his/her mouth that lasts for a few minutes. Occasionally, a ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... if sedation or anesthesia is to be used. In general, children who have recently been ill will ... generated during a CT scan can be reformatted in multiple planes, and can even generate three-dimensional ...

  17. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... for the chest x-ray, CT is the most commonly used imaging procedure for evaluating the chest. ... scanning, especially if the chest is being scanned. Most children older than six years are able to ...

  18. CT Demonstration of Caput Medusae

    Science.gov (United States)

    Weber, Edward C.; Vilensky, Joel A.

    2009-01-01

    Maximum intensity and volume rendered CT displays of caput medusae are provided to demonstrate both the anatomy and physiology of this portosystemic shunt associated with portal hypertension. (Contains 2 figures.)

  19. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... internal organs, bones, soft tissues and blood vessels. It may be used to help diagnose abdominal pain ... evaluate blood vessels throughout the body. With CT, it is possible to obtain very detailed pictures of ...

  20. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... you today about computed tomography colonography or, as it is more commonly known, virtual colonoscopy. Virtual colonoscopy ... might have some concerns about CT scanning. However, it’s important to consider the likelihood of benefit from ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... radiation children may receive from a CT scan. One of the best ways of limiting radiation exposure ... or pediatrician and the radiologist will decide which type of examination is best for your child. top ...

  2. CT manifestations of ileal dysgenesis

    Energy Technology Data Exchange (ETDEWEB)

    Oberhelman, Amy P.; Herman, Thomas E.; McAlister, William H. [St. Louis Children' s Hospital, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Department of Radiology, St. Louis, MO (United States); Keating, James P. [St. Louis Children' s Hospital, Mallinckrodt Department of Pediatrics, Washington University School of Medicine, Division of Gastroenterology, St. Louis, MO (United States); Rollins, Michael D.; Dillon, Patrick A. [St. Louis Children' s Hospital, Department of Surgery, Washington University School of Medicine, St. Louis, MO (United States)

    2007-02-15

    Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

  3. CT findings of the thymus

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Young; Kim, Yun Hwan; Seol, Hae Young; Chung, Woun Kyun; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1987-02-15

    In 14 cases of normal and abnormal thymus proved surgically and histopathologically in korea University Hae Wha Hospital during recent 6 years, the clinical and CT findings were analyzed. 1. Of 14 cases, 2 cases were normal thymus, 5 cases were thymic hyperplasia, 4 cases were benign thymoma, 2 case were malignant thymoma and 1 case was thymic cyst. 2. Of 14 cases, 10 cases were associated with myasthenia gravis, and 7 of these 10 cases were 3rd to 5th decades females. Among 10 cases with myasthenia gravis. 5 cases were thymic hyperplasia, 1 case was benign thymoma, 2 cases were malignant thymoma, and 2 cases were normal thymus. 3. All 5 thymic hyperplasia were associated with myasthenia gravis. CT findings of thymic hyperplasia were normal in 4 cases and increased lobe thickness in 1 case. 4. Of 4 cases of benign thymoma, only 1 case was associated with myasthenia gravis, and all 4 cases were positive findings in CT scan. CT findings of benign thymoma were round or oval soft tissue mass in anterior mediastinum, and 1 case had punctuate calcifications. 5. Of 2 cases of malignant thymoma, all 2 cases were associated with myasthenia gravis and positive findings in CT scan. CT findings of malignant thymoma were anterior mediastinal soft tissue mass with obliteration of the normal fat planes surrounding great vessels. SVC compression, and pleural tumor implants. 6. CT yielded significant diagnostic information of differential diagnosis between thymoma and thymoma hyperplasia in myasthenia gravis patients. Also CT was highly sensitive test in detection of thymoma and determined the extent and invasiveness of thymoma.

  4. Radiology for PET/CT reporting

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina; Fanti, Stefano; Zanoni, Lucia [Univ. Hospital Sant Orsola-Malpighi, Bologna (Italy). Dept. of Nuclear Medicine

    2014-07-01

    Offers rapid access to slice by slice CT descriptions of anatomical structures from PET/CT studies. Presents images and descriptions of CT findings that may be detected while reviewing PET/CT scans. Includes principal MRI findings in diseases susceptible to PET/CT evaluation. Reading PET/CT scans is sometimes challenging. Not infrequently, abnormal findings on CT images are functionally silent and therefore difficult for nuclear medicine practitioners to interpret. Furthermore, in general only a low-dose CT scan is produced as part of the combined PET/CT study, and the resulting CT images may prove suboptimal for image interpretation. This atlas is designed to enable nuclear medicine practitioners who routinely read PET/CT scans to recognize the most common CT abnormalities. Slice-by-slice descriptions are provided of anatomical structures as visualized on CT scans obtained in PET/CT studies. The CT findings that may be detected while reviewing PET/CT scans of various body regions and conditions are then illustrated and fully described. The concluding section of the book is devoted to the principal MRI findings in diseases which cannot be evaluated using PETs/CTs.

  5. Synthetic Hounsfield units from spectral CT data

    Science.gov (United States)

    Bornefalk, Hans

    2012-04-01

    Beam-hardening-free synthetic images with absolute CT numbers that radiologists are used to can be constructed from spectral CT data by forming ‘dichromatic’ images after basis decomposition. The CT numbers are accurate for all tissues and the method does not require additional reconstruction. This method prevents radiologists from having to relearn new rules-of-thumb regarding absolute CT numbers for various organs and conditions as conventional CT is replaced by spectral CT. Displaying the synthetic Hounsfield unit images side-by-side with images reconstructed for optimal detectability for a certain task can ease the transition from conventional to spectral CT.

  6. Cardiac CT: coronary arteries and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, Andreas H. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany); RWTH Aachen University, Applied Medical Engineering, Aachen (Germany); Muehlenbruch, Georg; Guenther, Rolf W.; Wildberger, Joachim E. [RWTH Aachen University, Department of Diagnostic Radiology, University Hospital, Aachen (Germany)

    2007-04-15

    Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles and essentials of these technical basics are described here. Correctly applied cardiac MDCT allows imaging of the coronary arteries including coronary anatomy and stenosis detection. The same is true for evaluation of coronary artery bypass grafts and, to some extent, coronary artery stents. While quantification of total calcified plaque burden has been long established, coronary MDCT allows assessing plaque morphology and constitution. Recent approaches go beyond the coronaries and include evaluation of left ventricular function at rest and myocardial viability. In combination with experimental approaches for assessing aortic valve function and myocardial perfusion imaging, cardiac MDCT offers the potential for a comprehensive examination of the heart using a single breath-hold examination. (orig.)

  7. Validation of a method to differentiate arterial and venous vessels in CT perfusion data using linear combinations of quantitative time-density curve characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Havla, Lukas; Schneider, Moritz; Dietrich, Olaf [Ludwig-Maximilians-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging, Institute for Clinical Radiology, Munich (Germany); Thierfelder, Kolja M.; Beyer, Sebastian E.; Ertl-Wagner, Birgit; Sommer, Wieland H. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-10-15

    We aimed to develop and evaluate a new method that reliably differentiates between cerebral arteries and veins using voxel-wise CT-perfusion-derived parameters. Fourteen consecutive patients with suspected stroke but without pathological findings were examined on a multi-detector CT system: 32 dynamic phases (∇t = 1.5 s) during application of 35 mL iomeprol-350 were acquired at 80 kV/200mAs. Three hemodynamic parameters were calculated for 18 arterial and venous vessel segments: A (maximum of the time-density-curve), T (time-to-peak), and W (full-width-at-half-maximum). Using receiver operator characteristic (ROC) curve analysis and Fisher's linear discriminant analysis (FLDA), the performance of every classifier (A, T, W) and of all linear combinations for the differentiation of arterial and venous vessels was determined. A maximum area under the ROC-curve (AUC) of 0.945 (accuracy = 86.8 %) was obtained using the FLDA combination of A and T or the triplet FLDA of A and T and W for the classification of venous and arterial vessels. The best single parameter was T with an AUC of 0.871 (accuracy = 79.0 %), which performed significantly worse than the combination A and T (p < 0.001). Arteries and veins can be accurately differentiated based on dynamic CT perfusion data using the maximum of the time-density curve, its time-to-peak, its width, and FLDA combinations of these parameters, which yield accuracies up to 87 %. (orig.)

  8. A systematic review of the need for MRI for the clearance of cervical spine injury in obtunded blunt trauma patients after normal cervical spine CT

    Directory of Open Access Journals (Sweden)

    Iyore AO James

    2014-01-01

    Full Text Available Clearance of cervical spine injury (CSI in the obtunded or comatose blunt trauma patient remains controversial. In patients with unreliable physical examination and no evidence of CSI on computed tomography (CT, magnetic resonance imaging of the cervical spine (CS-MRI is the typical follow-up study. There is a growing body of evidence suggesting that CS-MRI is unnecessary with negative findings on a multi-detector CT (MDCT scan. This review article systematically analyzes current literature to address the controversies surrounding clearance of CSI in obtunded blunt trauma patients. A literature search through MEDLINE database was conducted using all databases on the National Center for Biotechnology Information (NCBI website (www.ncbi.nlm.nih.gov for keywords: "cervical spine injury," "obtunded," and "MRI." The search was limited to studies published within the last 10 years and with populations of patients older than 18 years old. Eleven studies were included in the analysis yielding data on 1535 patients. CS-MRI detected abnormalities in 256 patients (16.6%. The abnormalities reported on CS-MRI resulted in prolonged rigid c-collar immobilization in 74 patients (4.9%. Eleven patients (0.7% had unstable injury detected on CS-MRI alone that required surgical intervention. In the obtunded blunt trauma patient with unreliable clinical examination and a normal CT scan, there is still a role for CS-MRI in detecting clinically significant injuries when MRI resources are available. However, when a reliable clinical exam reveals intact gross motor function, CS-MRI may be unnecessary.

  9. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  10. CT of pelvic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Falchi, Marco E-mail: marcofalchi@yahoo.it; Rollandi, Gian Andrea

    2004-04-01

    Although magnetic resonance imaging has become the dominant modality for cross-sectional musculo-skeletal imaging, the widespread availability, speed, and versatility of computed tomography (CT) continue to make it a mainstay of emergency room (ER) diagnostic imaging. Pelvic ring and acetabular fractures occur as the result of significant trauma secondary to either a motor vehicle accident or a high-velocity fall. These injuries are correlated with significant morbidity and mortality, both from the complications of pelvic ring fractures and from commonly associated injuries. The most commonly used classification of pelvic and acetabular fractures has been based on conventional radiographs that are, in the majority of cases, sufficient to determine the type of injury. However, because of the complexity of pelvic and acetabular fractures, precise pathological anatomy is not easily demonstrated by routine radiographs and in many cases details of fractures are not visible. Moreover, the insufficient co-operation of the patient or the difficulty of maintaining special positions can be overcome by using computed tomography. Spiral computed tomography provides information regarding the extent of the fractures and is complementary to radiography for ascertaining the spatial arrangement of fracture fragments. Spiral computed tomography is an effective tool for understanding complex fracture patterns, particularly when combined with multi-planar reconstruction two-dimensional (MPR 2D) reformatted images or three-dimensional images (3D) images. Including these techniques of reconstruction in routine pelvic imaging protocols can change management in a significant number of cases. Subtle fractures, particularly those oriented in the axial plane, are better seen on MPR images or 3D volume-rendered images. Complex injuries can be better demonstrated with 3D volume-rendered images, and complicated spatial information about the relative positions of fracture fragments can be easily

  11. Functional CT of the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Tsushima, Yoshito. E-mail: yoshito@xa2.so-net.ne.jp

    1999-06-01

    The iodinated contrast agents used for computed tomography (CT) are filtered at the glomerulus and not reabsorbed by the tubules and have pharmacokinetics comparable to inulin. They can thus measure physiological indices such as contrast clearance per unit volume, which is closely related to glomerular filtration rate per unit renal volume of kidney, after due allowance for the difference between blood and plasma clearance. In this review, we show how dynamic CT can be used to measure both regional and global blood clearance of contrast material. A single slice of kidney is scanned sequentially after bolus intravenous (i.v.) injection of contrast material. Next, time-attenuation curves are constructed and contrast clearance per unit volume is calculated using a Patlak graphical analysis. CT determination of renal volume is made and global contrast clearance can be then also calculated. In normal kidneys, clearance/volume averaged 0.49{+-}0.11 ml min{sup -1} ml{sup -1} (mean {+-}S.D.), and these values agreed with literature data obtained using other techniques. A negative correlation between patient's age and clearance/volume was seen. A strong correlation was observed between creatinine whole blood clearance and the global contrast clearance (the product of renal volume determined by CT and contrast clearance/volume). Dynamic CT can provide quantitative renal physiological information on a regional basis non-invasively.

  12. CT finding of cryptococcal meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Y.; Sato, H.; Ueda, M.; Ito, K.; Matsuoka, T. (Ohkawara Neurosurgical Hospital, Muroran (Japan))

    1981-08-01

    We have experienced 14 cases of cryptococcal meningitis in the last 6 years. Their neurological signs, CT findings, and prognoses were studied. They fall into three types: the brain-stem-encephalitis type, the cortical-encephalitis type, and the meningitis type, according to the clinical course. The first type (6 cases) revealed mainly cerebellar signs, eye-movement damage, and so forth. The second type (5 cases) demonstrated ''Personality'' changes, chiefly aphasia. The third type (5 cases) did not show any focal signs. Prognosis of the brain-stem-encephalitis type was very poor, with a 50% mortality rate. In the survivors, also, clinical signs did not disappear for a long time. Repeated CT was performed in 13 among the 14 cases; abnormal CT findings were revealed in 5 cases because of cryptococcal infection. Granuloma shadow and ventriculitis shadow were observed in 3 cases each. These abnormal findings disappeared upon treatment except in one case. The clinical signs are not completely related with the CT finding, but it is useful that the site which has been infiltrated by the cryptococcus can be observed. Abnormal CT findings were observed in the 4 cases of the brain-stem-encephalitis type among the 5 abnormal cases. It is very useful to know the severity of the condition.

  13. Cerebral CT of ischaemic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Aulich, A.

    1981-11-25

    The diagnosis of stroke must first be established by clinical examination. CT has proved useful for confirmation of the diagnosis and provides a global intracranial picture of morphological changes in cerebral vascular diseases. A hemorrhage can be recognized with certainty at the first CT examination as the cause of the stroke, but in the detection of a lesion due to ischemia an important role is played by the correct choice of the time of examination, and in some cases also of the check-up with contrast medium. The differential diagnosis between infarct in the acute stage and encephalitis or gliomas of low-grade malignity can be difficult. A decision can often only be made after a series of examinations. Postmalacial conditions are often difficult to differentiate from defects due to other causes, such as hemorrhage, head injury, postoperative states and after encephalitis. A knowledge of the anamnesis and the clinical findings is indispensable for CT evaluation. In assessing the prognosis before vascular surgery on the extracranial brain-supplying vessels the performance of a CT examination should be advised. A warning is given against the use of CT as a screening method.

  14. CT diagnosis of empty sella

    Energy Technology Data Exchange (ETDEWEB)

    Machida, T.; Maehara, T. (Tokyo Univ. (Japan). Faculty of Medicine)

    1981-02-01

    The CT diagnosis of an empty sella was discussed, using coronal and reconstructed sagittal planes after the intrathecal injection of metrizamide. Results: 1) The diagnosis of an empty sella should be made by noninvasive radiological examination, if possible. Computed Tomography is the most appropriate procedure for the diagnosis of an empty sella. 2) Coronal and reconstructed sagittal CT are of more diagnostic use than axial CT in the diagnosis of an empty sella. 3) At present, we should use metrizamide to eliminate a low-density mass in sella turcica. 4) In the near future, we will be able to make a diagnosis of an empty sella by plain CT alone, using a thinner slice and a higher resolution for low attenuation values. 5) We cannot detect pituitary microadenoma itself by CT in most cases of pituitary adenomas with a coexisting partially empty sella. We should, therefore, use other, detailed neuroradiological investigations if the endocrinologic evaluation of a patient supports the possibility of pituitary adenoma.

  15. CT Imaging: Basics and New Trends

    Science.gov (United States)

    Peyrin, Françoise; Engelke, Klaus

    This chapter presents the principle of X-ray CT and its evolution during the last 40 years. The first section describes the physical basis of X-ray CT, tomographic image reconstruction algorithms, and the source of artifacts in X-ray CT images. The second section is devoted to the evolution of CT technology from the first translation-rotation systems to multi-slice spiral CTs currently used today. The next section addresses specific developments of CT technology and applications, like perfusion CT, quantitative CT, and spectral CT. The fourth section introduces the problem of radiation exposure delivered to the patient and its evaluation. Finally the last section addresses the development in micro- and even nano-CT which is a rapidly evolving area in preclinical imaging and biology.

  16. Radiation Doses of Dual-Energy CT for Abdominopelvic CT: Comparison with Single-Energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Seo; Jeong, Woo Kyoung; Kim, Yong Soo; Heo, Jeong Nam [Dept. of Radiology, Hanyang University Guro Hospital, Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    To compare radiation doses of dual-energy CT (DECT) to single-energy CT (SECT) by a phantom experiment, with the application of mean tube currents for abdomino-pelvic CT. This study includes patients who were examined by contrast-enhanced CT for kidney evaluation. We divided the patients into six groups according to sex and body mass index. Each group consisted of five patients and a total of 30 patients were evaluated. We split the body parts (abdomen and pelvis), and calculated the mean tube current of each group as well as investigated the image noise. Applying the mean mAs from a CT scan, we measured the weighted CT dose index (CTDIw) of DECT and SECT. We compared the measured CTDIw to an estimated CTDI value displayed on the CT console. We also compared the radiation dose ratio of DECT to SECT (D/S ratio) for each subgroup. The radiation doses were compared by the student's t-test and analysis of variance. The difference of image noise between DECT and SECT was not statistically significant. Radiation dose of DECT was higher than SECT by about 21.6% (10.69 mGy, 8.79 mGy; p < 0.0001), and the measured CTDI of the DECT was significantly higher than the estimated CTDI by about 6% (p < 0.001). The D/S ratio was not significant between the six groups. The measured CTDIw of abdominopelvic DECT studies were significantly higher than those of SECT.

  17. Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Yuan Heng; Jaw, Fu Shan [National Taiwan University, Taipei, Taiwan (China); Wang, Yung Cheng; Jeng, Chin Ming [Fu Jen Catholic University, Taipei, Taiwan (China); Peng, Shinn Forng [National Taiwan University Hospital, Taipei, Taiwan (CN)

    2011-06-15

    The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 {+-} 17 and 80 {+-} 10 mmHg; 120 {+-} 14 and 80 {+-} 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 {+-} 9.3 and 70.6 {+-} 8.9 mL/m2; 23.5 {+-} 5.7 and 25.6 {+-} 3.7 mL/m2, 66.5 {+-} 5.1% and 63.5 {+-} 4.6%, respectively). The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

  18. Primary hepatic sarcomas: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ri-Sheng; Chen, Ying; Jiang, Biao; Wang, Liu-Hong [Zhejiang University School of Medicine, Department of Radiology, Hangzhou (China); Xu, Xiu-Fang [Zhejiang Medical College, Teaching and Research Group of Radiology, Hangzhou (China)

    2008-10-15

    Primary hepatic sarcomas are rare tumors that are difficult to diagnose clinically. Different primary hepatic sarcomas may have different clinical, morphologic, and radiological features. In this pictorial review, we summarized computed tomography (CT) findings of some relatively common types of hepatic sarcomas, including angiosarcoma, epithelioid hemangioendothelioma (EHE), liposarcoma, undifferentiated embryonal sarcoma (UES), leiomyosarcoma, malignant fibrous histiocytoma (MFH), and carcinosarcoma (including cystadenocarcinosarcoma). To our knowledge, hepatic cystadenocarcinosarcoma has not been described in the English literature. The CT findings in our case are similar to that of cystadenocarcinoma, a huge, multilocular cystic mass with a large mural nodule and solid portion. The advent of CT has allowed earlier detection of primary hepatic sarcomas as well as more accurate diagnosis and characterization. In addition, we briefly discuss the MRI findings and diagnostic value of primary hepatic sarcomas. (orig.)

  19. Primary thyroid lymphoma: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo-Cheol; Han, Moon Hee E-mail: hanmh@radcom.snu.ac.kr; Kim, Keon Ha; Jae, Hwan Jun; Lee, Sang Hyun; Kim, Sam Soo; Kim, Kwang Hyun; Chang, Kee-Hyun

    2003-06-01

    Introduction: To evaluate the computed tomographic (CT) findings of primary thyroid lymphoma. Methods and material: The clinicopathological data and CT images of nine patients with primary thyroid lymphoma were retrospectively reviewed. The CT appearances were classified into three types: type 1, a solitary nodule surrounded by normal thyroid tissue; type 2, multiple nodules in the thyroid, and type 3, a homogeneously enlarged both thyroid glands with a reduced attenuation with or without peripheral thin hyperattenuating thyroid tissue. Results: All patients had a rapidly enlarging thyroid mass and coexistent Hashimoto's thyroiditis. One patient showed type 1 pattern, three type 2, and five type 3. Six patients had homogeneous tumor isoattenuating to surrounding muscles. The tumors had a strong tendency to compress normal remnant thyroid and the surrounding structure without invasion. Conclusion: Primary thyroid lymphoma should be included in the differential diagnosis when old female had a homogeneous thyroidal mass isoattenuating to muscles, which does not invade surrounding structures.

  20. CT and HR-CT of exogenous allergic alveolitis. Exogen allergische Alveolitis in CT und HR-CT

    Energy Technology Data Exchange (ETDEWEB)

    Lederer, A.; Kullnig, P. (Graz Univ., Univ.-Klinik fuer Radiologie (Austria)); Pongratz, M. (Graz Univ. (Austria). Abt. fuer Lungenkranke)

    1992-09-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.).

  1. A New Proton CT Scanner

    CERN Document Server

    Coutrakon, G; Boi, S; Dyshkant, A; Erdelyi, B; Hedin, D; Johnson, E; Krider, J; Rykalin, V; Uzunyan, S A; Zutshi, V; Fordt, R; Sellberg, G; Rauch, J E; Roman, M; Rubinov, P; Wilson, P; Naimuddin, M

    2014-01-01

    The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to calculate doses to tumor and healthy tissues. One of the limitations of X-ray CT is in the conversion of X-ray attenuation coefficients to relative (proton) stopping powers, or RSP. This results in more proton range uncertainty, larger target volumes and therefore, more dose to healthy tissues. To help improve this, we present a novel scanner capable of high dose rates, up to 2~MHz, and large area coverage, 20~x~24~cm$^2$, for imaging an adult head phantom and reconstructing more accurate RSP values.

  2. Comparison of Two Accelerators for Monte Carlo Radiation Transport Calculations, NVIDIA Tesla M2090 GPU and Intel Xeon Phi 5110p Coprocessor: A Case Study for X-ray CT Imaging Dose Calculation

    Science.gov (United States)

    Liu, Tianyu; Xu, X. George; Carothers, Christopher D.

    2014-06-01

    Hardware accelerators are currently becoming increasingly important in boosting high performance computing sys- tems. In this study, we tested the performance of two accelerator models, NVIDIA Tesla M2090 GPU and Intel Xeon Phi 5110p coprocessor, using a new Monte Carlo photon transport package called ARCHER-CT we have developed for fast CT imaging dose calculation. The package contains three code variants, ARCHER - CTCPU, ARCHER - CTGPU and ARCHER - CTCOP to run in parallel on the multi-core CPU, GPU and coprocessor architectures respectively. A detailed GE LightSpeed Multi-Detector Computed Tomography (MDCT) scanner model and a family of voxel patient phantoms were included in the code to calculate absorbed dose to radiosensitive organs under specified scan protocols. The results from ARCHER agreed well with those from the production code Monte Carlo N-Particle eXtended (MCNPX). It was found that all the code variants were significantly faster than the parallel MCNPX running on 12 MPI processes, and that the GPU and coprocessor performed equally well, being 2.89~4.49 and 3.01~3.23 times faster than the parallel ARCHER - CTCPU running with 12 hyperthreads.

  3. [Gallstone ileus. Abdominal CT usefulness].

    Science.gov (United States)

    Sukkarieh, F; Brasseur, P; Bissen, L

    2004-06-01

    The authors report the case of a 93-year old woman referred to the emergency department and presenting with an intestinal obstruction. Abdominal CT reveals a biliary ileus caused by the migration and the impaction of a 3 cm gallstone in the small bowel. Surgical treatment by enterolithotomy was successful. In over 90% of cases, gallstone ileus is a complication of cholelithiasis and accounts for 25% of intestinal obstruction in patients over 65 years. To reduce morbidity and mortality, early diagnosis and prompt treatment are essential. Abdominal CT-scan is the gold standard technique.

  4. Normal pediatric postmortem CT appearances

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Willemijn M.; Bosboom, Dennis G.H.; Koopmanschap, Desiree H.J.L.M. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Nikkels, Peter G.J. [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Rijn, Rick R. van [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands)

    2015-04-01

    Postmortem radiology is a rapidly developing specialty that is increasingly used as an adjunct to or substitute for conventional autopsy. The goal is to find patterns of disease and possibly the cause of death. Postmortem CT images bring to light processes of decomposition most radiologists are unfamiliar with. These postmortem changes, such as the formation of gas and edema, should not be mistaken for pathological processes that occur in living persons. In this review we discuss the normal postmortem thoraco-abdominal changes and how these appear on CT images, as well as how to differentiate these findings from those of pathological processes. (orig.)

  5. WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow.

    Science.gov (United States)

    Chen, G

    2016-06-01

    1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT.

  6. Preliminary study on CT perfusion imaging in guiding biopsy of pulmonary lumps

    Institute of Scientific and Technical Information of China (English)

    KANG Li-qing; SONG Zhao-wei; LI Zhong-xin; YU Shu-jing; LIU Feng-hai; CHEN Yue-feng; XING Rong-ge

    2009-01-01

    /69) respectively,and the difference was statistically significant between group Ⅰ and Ⅲ (P <0.01 ).For the central type,they were 11% (2/18),24% (4/17),and 57%(8/14) respectively,and the difference was statistically significant between group Ⅰ and Ⅲ (P <0.01).For the peripheral type,they were 20% (3/15),29% (8/28),and 40% (22/55) respectively,and no statistically significant difference was found among the three groups.Conclusions CTP guided biopsy of pulmonary lumps using multi-detector row CT has the potential to improve the accuracy of histopathological diagnosis with a lower risk and higher achievement ratio.More research and technical improvements are needed before it is widely used.

  7. Primitive neuroectodermal tumor: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo; Eun, Tchoong Kie; Cha, Seong Sook; Han, Sang Suk; Chung, Duck Hwan [Inje College, Paik Hospital, Busan (Korea, Republic of)

    1987-04-15

    Primitive neuroectodermal tumor is a neoplasm of young individuals that occurs predominantly in the supratentorial compartment. Authors experienced three cases of primitive neuroectodermal tumor. On the brain CT scans, all three cases reveal the large, irregular, hyperdense mass lesions with calcifications and cystic or necrotic areas, and show dense heterogeneous contrast enhancement.

  8. CT of retrorenal fluid collections

    Energy Technology Data Exchange (ETDEWEB)

    Love, L.; Demos, T.C.; Posniak, H.

    1985-07-01

    Fluid collections dorsal to one or both kidneys are often observed on CT. Most of these collections are located in the posterior pararenal space, but occasionally fluid collections that do not originate in this space also occur. The authors review retrorenal fluid collections with explanations for their occurrence.

  9. CT findings of osteogenesis imperfecta

    Energy Technology Data Exchange (ETDEWEB)

    Kojo, Nobuto; Otsuru, Katsuyasu; Lee, Soichi; Takagi, Shigeyuki; Shigemori, Minoru.

    1987-08-01

    Two cases of osteogenesis imperfecta found in one family (father and daughter) are reported, and the CT findings are described. Case 1 is a 58-year-old man who fell and struck his head at home on November 10, 1984. He was transferred to Omuta City Hospital when he became semicomatose and decerebrate posturing was noted. His family history revealed 8 persons with osteogenesis imperfecta. A skull X-ray film showed a large skull vault, many wormian bones at the lambdoid suture, platybasia, and a basilar impression. A CT scan demonstrated a right acute subdural hematoma, while the bone image showed well-developed mastoid air cells and a skull deformity characteristic of osteogenesis imperfecta. He had an emergency operation, and a 170-gr clot was successfully evacuated. A postoperative CT scan demonstrated brain atrophy, possibly present before head trauma. Case 2 is the daughter of Case 1 (a 27-year-old woman). She also showed characteristic neuroradiological manifestations on a plain skull film and on a CT scan. A basilar impression and platybasia were also demonstrated. In this report, the possible mechanism of the production of a traumatic acute subdural hematoma is also discussed.

  10. Evaluation strategies in CT scanning

    DEFF Research Database (Denmark)

    uncertainty. This investigation includes measurements of two industrial items, an aluminum pipe connector and a plastic toggle, a hearing aid component. These are measured using a commercial CT scanner. Traceability is transferred using tactile and optical coordinate measuring machines, which are used...

  11. CT findings of thymic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Ho Son; Lee, Sang Jin; Hwang, Mi Soo; Cho, Kil Ho; Chang, Jae Chun; Park, Bok Hwan [College of Medicine, Yeungnam University, Daegu (Korea, Republic of)

    1991-05-15

    A CT scan can make accurate diagnoses of most thymic masses by assessing their size, shape, and internal architecture and is especially effective in detecting pleural implants, mediastinal involvement, and pulmonary parenchymal invasion in malignant thymoma. The authors analyzed the CT findings of 10 histologically-proven thymic masses from 1983 to 1990 in Yeungnam University Hospital. There were 10 cases of thymic masses in the anterior mediastinum consisting of 6 benign, 3 invasive thymomas, and one thymolipoma, while myasthenia gravis was associated with 2 cases of benign thymomas and with one case of invasive thymomas. The CT findings of the benign thymomas (6 cases) were well-defined, bordered, round-or oval-shaped masses with a well-preserved fat plane between the thymic mass and mediastinal great vessels, with no evidence of pleural implants and lung parenchymal invasion. The CT findings of the invasive thymomas (3 cases) were irregular, marginated lobular masses with obliteration of the fat plane between the thymic mass and surrounding great vessels, with evidence of local invasion such as extension to A-P window and mass effect to bronchus. Irregular pleural thickening due to pleural metastasis, multiple metastatic lung parenchymal nodules, and multiple mediastinal lymph node enlargement were also seen in the invasive thymomas. One case of thymolipoma showed an approximately 20cm-size, well-defined fat density mass containing internal septations.

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... E-mail: Area code: Phone no: Thank you! Images × Image Gallery A child being prepared for a CT ... address): From (your name): Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... to help diagnose abdominal pain or evaluate for injury after trauma. Tell your doctor about your child’s medications and ... diagnose a wide range of conditions due to injury or illness. In children, CT is typically used ...

  15. Acute pancreatitis: clinical vs. CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Hill, M.C. (Univ. of Miami, FL); Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-08-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months.

  16. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19, ... The ECG is also needed to help the computer that is connected to the CT scanner create ...

  17. CT diagnosis of gall stone ileus

    Energy Technology Data Exchange (ETDEWEB)

    Leen, G.L.S.; Finlay, M. (Royal Victoria Infirmary, Newcastle upon Tyne (UK). Dept. of Radiology Newcastle General Hospital, Newcastle upon Tyne (UK). Dept. of Radiology)

    1990-09-01

    We report a case of gall stone ileus in which only small bowel obstruction was seen on the conventional abdominal film and the diagnosis was made by computed tomography (CT). With the availability of CT and its increasing use in the investigation of the acute abdomen, CT examination will occasionally be performed on gall stone ileus patients. Awareness of the CT findings in gall stone ileus will result in early diagnosis leading to a reduction in the mortality rate. (orig.).

  18. CT "halo sign" in pulmonary tuberculoma.

    Science.gov (United States)

    Gaeta, M; Volta, S; Stroscio, S; Romeo, P; Pandolfo, I

    1992-01-01

    The CT halo sign has been described as the CT finding of a low-attenuation zone surrounding a pulmonary nodule. It is an early clue to the diagnosis of invasive pulmonary aspergillosis. We describe a case of CT halo sign associated with a pulmonary tuberculoma. Therefore, we think that a diagnosis other than invasive pulmonary aspergillosis should be considered in the presence of the CT halo sign in immunocompetent patients.

  19. CT findings of acoustic neuroma

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Do Choul; Lee, Jae Mun; Shinn, Kyung Sub; Bahk, Yong Whee [Catholic Univ., Seoul (Korea, Republic of)

    1987-10-15

    Computed Tomography (CT) is very accurate in evaluating the location, size, shape and extension of acoustic neuroma. We analysed CT findings of 23 acoustic neuromas seen at Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College during the period of from January 1981 to June 1987. 1. Five (22%) were men and 18 (78%) were women with the high incidence occurring in the 4th and 5th decades. 2. Twenty two cases were diagnosed satisfactorily by CT examinations which included axial, coronal and reconstruction images. One with the smallest dimension of 8 mm in diameter could not be detected by the conventional CT scan. But is could be seen after metrizamide cisternography. mean size of the tumor masses was estimated 3.6 cm in diameter. 3. The shape of the tumor was oval in 50%, round in 27% and lobulated in 23%. The masses were presented as hypodense in 50%, isodense in 32% and hyperdense in 18%. All tumors were extended from the internal acoustic and toward the cerebellopontine angle. The internal acoustic canal was widened in 77%. Hydrocephalus was associated in 45%. Widening of cerebellopontine angle cistern was noted in 50%. 4. After contrast infusion the tumors were enhanced markedly in 45%, moderately in 32% and mildly in 23%. The enhanced pattern was homogeneous in 41%, mixed in 41% and rim in 18%. The margin of the tumors was sharply defined in 82%. The tumors were attached to the petrous bone with acute angle in 73%. Cystic change within the tumor was found in 27%. The peritumoral edema was noted in 45%. In conclusion, CT is of most effective modalities to evaluate size, shape, extent and internal architecture of acoustic neuroma as well as relationship with adjacent anatomic structures including the internal acoustic canal.

  20. CT for laryngeal and hypopharyngeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Ohata, Takeo (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine)

    1982-10-01

    In 12 cases of laryngeal cancer and 3 of hypopharyngeal cancer, CT findings were compared with endoscopic and laryngographic findings. CT revealed tumor invasion into the piriform sinus, vallecula, cricoarytenoid articulate and laryngeal cartilage, while the other two methods did not. Cases were presented and CT findings of laryngeal and hypopharyngeal cancers were summarized.

  1. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  2. A comparison of seminal vesicle size on CT between autosomal dominant polycystic kidney disease (ADPKD) patients and normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Ijin; Kim, Seung Hyup; Cho, Jeong Yeon (Dept. of Radiology, Seoul National Univ. College of Medicine, Inst. of Radiation Medicine, Seoul National Univ., Seoul (Korea)), e-mail: kimsh@radcom.snu.ac.kr

    2010-06-15

    Background: Extrarenal manifestations are common in autosomal dominant polycystic kidney disease (ADPKD). Although seminal vesicles can also be involved in patients with ADPKD, little is known about the size differences of the seminal vesicles between ADPKD patients and normal subjects. Purpose: To determine whether the size of seminal vesicles in ADPKD patients is larger than that in normal subjects with the use of three-dimensional (3D) CT. Material and Methods: Using a retrospective case-control study design, we reviewed the findings of 696 male patients with an age range of 20-69 years who underwent contrast enhanced multi-detector computed tomography (MDCT) imaging of the kidney in our institution from August 2007 to July 2008. A total of 68 male patients with ADPKD comprised the study group. Another 68 age-matched non-ADPKD male patients comprised the control group. The size of bilateral seminal vesicles was assessed by measurement of the short dimension on axial, coronal, and sagittal images by the use of a picture archiving and communication system (PACS). Results: The mean width of seminal vesicles in ADPKD patients was 1.70+-0.40 cm (axial images), 1.86+-0.45 cm (coronal), and 1.59+-0.39 cm (sagittal). For control group subjects, the mean width was 1.53+-0.29 cm (axial), 1.68+-0.43 cm (coronal), and 1.48+-0.31 cm (sagittal). The mean size differences between the ADPKD and control groups for the measured widths on axial and coronal images were statistically significant (P=0.01 and P=0.02, respectively). The width as measured on axial images showed a decrease with age in the control group subjects (linear trend, P=0.005), but no significant decrease was noted in ADPKD patients. Conclusion: The seminal vesicles were demonstrated to be larger in ADPKD patients as compared with normal subjects as determined with the use of 3D CT . Keywords: Autosomal dominant polycystic kidney disease (ADPKD), seminal vesicle, computed tomography, CT

  3. Whole brain CT perfusion on a 320-slice CT scanner

    Directory of Open Access Journals (Sweden)

    Jai Jai Shiva Shankar

    2011-01-01

    Full Text Available Computed tomography perfusion (CTP has been criticized for limited brain coverage. This may result in inadequate coverage of the lesion, inadequate arterial input function, or omission of the lesion within the target perfusion volume. The availability of 320-slice CT scanners offers whole brain coverage. This minimizes the chances of misregistration of lesions regardless of location, and makes the selection of the arterial input function easy. We present different clinical scenarios in which whole brain CTP is especially useful.

  4. Overview of multisource CT systems and methods

    Science.gov (United States)

    Zhao, Jun; Lu, Yang; Zhuang, Tiange; Wang, Ge

    2010-09-01

    Multiple-source cone-beam scanning is a promising mode for dynamic volumetric CT/micro-CT. The first dynamic CT system is the Dynamic Spatial Reconstructor (DSR) built in 1979. The pursuance for higher temporal resolution has largely driven the development of CT technology, and recently led to the emergence of Siemens dual-source CT scanner. Given the impact and limitation of dual-source cardiac CT, triple-source cone-beam CT seems a natural extension for future cardiac CT. Our work shows that trinity (triple-source architecture) is superior to duality (dual-source architecture) for helical cone-beam CT in terms of exact reconstruction. In particular, a triple-source helical scan allows a perfect mosaic of longitudinally truncated cone-beam data to satisfy the Orlov condition and yields better noise performance than the dual-source counterpart. In the (2N+1)-source helical CT case, the more sources, the higher temporal resolution. In the N-source saddle CT case, a triple-source scan offers the best temporal resolution for continuous dynamic exact reconstruction of a central volume. The recently developed multi-source cone-beam algorithms include an exact backprojection-filtration (BPF) approach and a "slow" exact filtered-backprojection (FBP) algorithm for (2N+1)-source helical CT, two fast quasi-exact FBP algorithms for triple-source helical CT, as well as a fast exact FBP algorithm for triple-source saddle CT. Some latest ideas will be also discussed, such as multi-source interior tomography and multi-beam field-emission x-ray CT.

  5. CT findings at lupus mesenteric vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, S.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lee, T.Y. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Cheng, T.T. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Ng, S.H. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lai, H.M. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Cheng, Y.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Tsai, C.C. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan)

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.).

  6. Utility of CT in branemark implant treatment

    Energy Technology Data Exchange (ETDEWEB)

    Yosue, Takashi; Takamori, Hitoshi; Nomura, Atsushi; Watanabe, Kaichi; Kamezawa, Hiroshi; Ohtani, Kazuo; Hiraga, Yasushi; Nakaya, Hiroshi (Nippon Dental Univ., Tokyo (Japan))

    1992-12-01

    Since the implant prognosis depends on the diagnosis, we use CT or tomography in addition to ordinary radiographic procedures to diagnose the propriety. Here we would like to present the diagnostic value of CT. We have performed CT examinations for 55 patients (66 jaws) up to the end of May 1992. In addition to the one-dimensional observation of CT images, we routinely used reconstructed CT images for the valuation of bone quality and quantity. The reconstructed CT images provided precise information regarding the width and height of the alveolar creat. The axial CT view provides more precise information on jawbone structure than panoramic radiographs. The CT number gives a quick estimate of jawbone quality. Because the image reconstruction requires only axial CT radiographs, metal restorations on the opposite jaw do not affect radiographic images. We have to take into account the partial volume effect, though. The disadvantages of CT use in diagnosis are an increase of time and of patient irradiation. The clarity of lower jaw CTs are especially sensitive to the patient movement. In conclusion, the CT radiographs are valuable in implant diagnosis. (author).

  7. Acute intestinal anisakiasis: CT findings.

    Science.gov (United States)

    Ozcan, H N; Avcu, S; Pauwels, W; Mortelé, K J; De Backer, A I

    2012-09-01

    Small bowel anisakiasis is a relatively uncommon disease that results from consumption of raw or insufficiently pickled, salted, smoked, or cooked wild marine fish infected with Anisakis larvae. We report a case of intestinal anisakiasis in a 63-year-old woman presenting with acute onset of abdominal complaints one day after ingestion of raw wild-caught herring from the Northsea. Computed tomography (CT) scanning demonstrated thickening of the distal small bowel wall, mucosa with hyperenhancement, mural stratification, fluid accumulation within dilated small-bowel loops and hyperemia of mesenteric vessels. In patients with a recent history of eating raw marine fish presenting with acute onset of abdominal complaints and CT features of acute small bowel inflammation the possibility of anisakiasis should be considered in the differential diagnosis of acute abdominal syndromes.

  8. Postmortem pulmonary CT in hypothermia.

    Science.gov (United States)

    Schweitzer, Wolf; Thali, Michael; Giugni, Giannina; Winklhofer, Sebastian

    2014-12-01

    Fatal hypothermia has been associated with pulmonary edema. With postmortem full body computed tomography scanning (PMCT), the lungs can also be examined for CT attenuation. In fatal hypothermia cases low CT attenuation appeared to prevail in the lungs. We compared 14 cases of fatal hypothermia with an age-sex matched control group. Additionally, 4 cases of carbon monoxide (CO) poisoning were examined. Furthermore, 10 test cases were examined to test predictability based on PMCT. Two readers measured CT attenuation on four different axial slices across the lungs (blinded to case group and other reader's results). Hypothermia was associated with statistically significantly lower lung PMCT attenuation and lower lung weights than controls, and there was a dose-effect relationship at an environmental temperature cutoff of 2 °C. CO poisoning yielded low pulmonary attenuation but higher lung weights. General model based prediction yielded a 94% probability for fatal hypothermia deaths and a 21% probability for non-hypothermia deaths in the test group. Increased breathing rate is known to accompany both CO poisoning and hypothermia, so this could partly explain the low PMCT lung attenuation due to an oxygen dissociation curve left shift. A more marked distension in fatal hypothermia, compared to CO poisoning, indicates that further, possibly different mechanisms, are involved in these cases. Increased dead space and increased stiffness to deflation (but not inflation) appear to be effects of inhaling cold air (but not CO) that may explain the difference in low PMCT attenuation seen in hypothermia cases.

  9. Multidetector CT of the Pancreas

    Directory of Open Access Journals (Sweden)

    Rossella Graziani

    2008-07-01

    Full Text Available Purpose. This book is a practical overview of pancreatic computer tomography (CT based on the large experience of the contributors. It is dedicated to Carlo Procacci a well known radiologist of Verona who died in 2004. Content. The book is divided into 10 chapters covering the different aspects of diagnostic CT of the pancreas. The various radiological aspects of acute and chronic pancreatitis, exocrine and endocrine pancreatic cancer (adenocarcinoma, neuroendocrine tumors, cystic cancer, rare neoplasms, traumatic abnormalities, imaging aspects of the gland after surgery and finally imaging findings after pancreas transplantation are reported in detail. Comment. We would emphasize that the characteristics of imaging of the common pancreatic diseases are described in addition to unusual or rare aspects of pancreatic pathology. The iconography is very rich and it is of excellent quality and it will help the radiologist to deal with individual cases particularly complex. Another important aspect of the book is that the initial approach of the various pancreatic diseases is based on clinical, surgical and pathological aspects and their relationship with imaging findings. Limitation. It is a great pity that the book for its importance is written in Italian language and for this reason it can not have an international appreciation. Final note. The radiologists will find in the book all the information useful for their daily practice. The internists, gastroenterologists and surgeons also will found useful information to better understand the information given by the modern CT radiology.

  10. Multi-Detector Analysis System for Spent Nuclear Fuel Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Reber, Edward Lawrence; Aryaeinejad, Rahmat; Cole, Jerald Donald; Drigert, Mark William; Jewell, James Keith; Egger, Ann Elizabeth; Cordes, Gail Adele

    1999-09-01

    The Spent Nuclear Fuel (SNF) Non-Destructive Analysis (NDA) program at INEEL is developing a system to characterize SNF for fissile mass, radiation source term, and fissile isotopic content. The system is based on the integration of the Fission Assay Tomography System (FATS) and the Gamma-Neutron Analysis Technique (GNAT) developed under programs supported by the DOE Office of Non-proliferation and National Security. Both FATS and GNAT were developed as separate systems to provide information on the location of special nuclear material in weapons configuration (FATS role), and to measure isotopic ratios of fissile material to determine if the material was from a weapon (GNAT role). FATS is capable of not only determining the presence and location of fissile material but also the quantity of fissile material present to within 50%. GNAT determines the ratios of the fissile and fissionable material by coincidence methods that allow the two prompt (immediately) produced fission fragments to be identified. Therefore, from the combination of FATS and GNAT, MDAS is able to measure the fissile material, radiation source term, and fissile isotopics content.

  11. Enhanced security for multi-detector Quantum Random Number Generators

    OpenAIRE

    Marangon, Davide G.; Vallone, Giuseppe; Zanforlin, Ugo; Villoresi, Paolo

    2016-01-01

    Quantum random number generators (QRNG) represent an advanced solution for randomness generation, essential in every cryptographic applications. In this context, integrated arrays of single photon detectors have promising applications as QRNGs based on the spatial detection of photons. For the employment of QRNGs in Cryptography, it is necessary to have efficient methods to evaluate the so called quantum min-entropy that corresponds to the amount of the true extractable quantum randomness fro...

  12. Modern CT applications in veterinary medicine.

    Science.gov (United States)

    Garland, Melissa R; Lawler, Leo P; Whitaker, Brent R; Walker, Ian D F; Corl, Frank M; Fishman, Elliot K

    2002-01-01

    Although computed tomography (CT) is used primarily for diagnosis in humans, it can also be used to diagnose disease in veterinary patients. CT and associated three-dimensional reconstruction have a role in diagnosis of a range of illnesses in a variety of animals. In a sea turtle with failure to thrive, CT showed a nodal mass in the chest, granulomas in the lungs, and a ball in the stomach. CT of a sea dragon with balance and movement problems showed absence of the swim bladder. In a sloth with failure to thrive, CT allowed diagnosis of a coin in the intestine. CT of a puffin with failure to thrive showed a mass in the chest, which was found to be a hematoma. In a smooth-sided toad whose head was tilted to one side and who was circling in that direction, CT showed partial destruction of the temporal bone. CT of a domestic cat with listlessness showed a mass with focal calcification, which proved to be a leiomyosarcoma. CT of a sea otter showed pectus excavatum, which is caused by the animal smashing oysters against its chest. In a Japanese koi with abdominal swelling, CT allowed diagnosis of a hepatoma.

  13. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  14. Monte Carlo dosimetry in CT; Dosimetria Monte Carlo en CT

    Energy Technology Data Exchange (ETDEWEB)

    Miro Herrero, R.

    2015-07-01

    Computed tomography explorations ITC) contribute a high percentage of the total radiation dose absorbed by the population exposed to medical examination. Since the number of CT scans performed has grown exponentially in recent years, concerns about their long-term effects on the patient's health has also increased. However, in order to establish a relationship between the absorbed dose and its side effects, it is necessary to perform a calculation accurate dosimetry radiation protection international institutions have confirmed that the best indicator of risk is dose to organs. (Author)

  15. CT findings of pancreatic disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi Sook; Park, In Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Medical Center, Jeonju (Korea, Republic of); Won, Jong Jin [College of Medicine, Wonkwang University, Iri (Korea, Republic of)

    1988-02-15

    CT was found to be a reliable, often specific, and noninvasive method for detecting pancreatic diseases. In a study of pancreatic lesions, 37 cases having satisfactory operative and histological proofs were analyzed by CT at PMC from Jan. 1986 to Oct. 1987. The results were as following: 1. Male:female is 26:11. 2. The incidence of pancreatic disease were as follows: 1) Pancreatic cancer:21 cases (56%) a.Head:12 cases b.Body:4 cases c.Tail:1 case d.Body and tail:1 case e.Uncinate process:2 cases f.Entire pancreas: 1 case 2) Acute pancreatitis: 6 cases (16%) 3) Chronic pancreatitis:5 cases (14%) 3. The characteristic CT findings: 1) 100% of pancreatic head cancer showed focal mass or alteration of pancreatic head contour and biliary tree dilatation, and 33% (7/12) fat line obliteration. 2) All of other pancreatic cancer except head appeared as focal mass or contour alteration and fat line obliteration. 3) Total 6 cases of acute pancreatitis showed that 5 cases diffuse enlargement of pancreas, 3 fluid collection (2 cases:left anterior pararenal and posterior pararenal space and lesser sac, 1 case:only pancreas body) and 1 case abscess formation. 4) Total 5 cases of chronic pancreatitis revealed diffuse enlargement 2 cases and atrophy 1 case, pancreatic ductal dilatation 3 cases, calcification 2 cases, and biliary tree dilatation with CBD tapering appearance 1 case. 5) All cases of pseudocysts were well marginated cystic lesions that located at head in 3 cases and tail 3 cases, and 4 cases were well defined pure cystic masses but 1 case was well capsulated cyst with multiple internal septation.

  16. [Phantom holder of CT couch].

    Science.gov (United States)

    Zhang, Ruixia; Zhan, Hongyu; Wang, Di

    2014-03-01

    This article describes a phantom holder in CT couch which adjusted easily and accurately, installed easily. The holder mainly include removing and locking equipment between phantom holder and table top, move horizontally equipment between left and right, rotating equipment between left and right. After holder and table top fixed one part, holder with phantom can move horizontally, front and back, rotate between left and right in a small angle, in order to make operator test phantoms accurately and easily. At the same time, this phantom holder realized free adjustment after first adjustments, which shortened operator work time.

  17. CT-arteriography of pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Jun; Matsui, Osamu; Kitagawa, Kiyohide; Kamimura, Ryoichi; Kadoya, Masumi; Suzuki, Masayuki; Takashima, Tutomu

    1985-01-01

    To evaluate diagnostic effectiveness of CT-arteriography (CTA) in pancreatic disease, the pictures of pancreatic CTA were analysed in 50 cases without pancreatic disease. In the pancreatic body, irregular spotty stain was seen in 15 out of 50 cases(30%). Especially, in patients who had dorsal pancreatic artery arising from superior mesenteric artery, this stain was seen in 9 out of 13 cases(69%) and its mechanism was considered to be double blood supply both from celiac artery and superior mesenteric artery. As a consequence, we think that CTA of pancreas is unusefull in diagnosis of pancreatic insulinomas or carcinomas. (author).

  18. CT appearances of abdominal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.-K., E-mail: leewk33@hotmail.com [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Van Tonder, F.; Tartaglia, C.J.; Dagia, C. [Department of Medical Imaging, St Vincent' s Hospital, University of Melbourne, Fitzroy, Victoria (Australia); Cazzato, R.L. [Department of Radiology, Universita Campus Bio-Medico di Roma, Rome (Italy); Duddalwar, V.A. [Department of Radiology, Norris Comprehensive Cancer Center, University of Southern California, Los Angeles, California (United States); Chang, S.D. [Department of Medical Imaging, Vancouver General Hospital, University of British Columbia, British Columbia (Canada)

    2012-06-15

    The purpose of this article is to review and illustrate the spectrum of computed tomography (CT) appearances of abdominal tuberculosis. Tuberculosis can affect any organ or tissue in the abdomen, and can be mistaken for other inflammatory or neoplastic conditions. The most common sites of tuberculosis in the abdomen include lymph nodes, genitourinary tract, peritoneal cavity and gastrointestinal tract. The liver, spleen, biliary tract, pancreas and adrenals are rarely affected, but are more likely in HIV-seropositive patients and in miliary tuberculosis. This article should alert the radiologist to consider abdominal tuberculosis in the correct clinical setting to ensure timely diagnosis and enable appropriate treatment.

  19. CT triage for lung malignancy

    DEFF Research Database (Denmark)

    Kusk, Martin Weber; Karstoft, Jens; Mussmann, Bo

    2015-01-01

    Background: Generation of multiplanar reformation (MPR) images has become automatic on most modern computed tomography (CT) scanners, potentially increasing the workload of the reporting radiologists. It is not always clear if this increases diagnostic performance in all clinical tasks. Purpose...... the performance of the four readers, using the area under the curve (AUC) as figure of merit. Results: No statistically significant difference of sensitivity and specificity was found for any of the readers when compared to the original reports. ROC analysis yielded AUCs in the range of 0.92–0.93 for all readers...

  20. CT Colonography: Pitfalls in Interpretation

    Science.gov (United States)

    Pickhardt, Perry J.; Kim, David H.

    2012-01-01

    Synopsis As with any radiologic imaging test, there are a number of potential interpretive pitfalls at CT colonography (CTC) that need to be recognized and handled appropriately. Perhaps the single most important step in learning to avoid most of these diagnostic traps is simply to be aware of their existence. With a little experience, most of these potential pitfalls will be easily recognized. This review will systematically cover the key pitfalls confronting the radiologist at CTC interpretation, primarily dividing them into those related to technique and those related to underlying anatomy. Tips and pointers for how to effectively handle these potential pitfalls are included. PMID:23182508

  1. Multimodal CT in stroke imaging: new concepts.

    Science.gov (United States)

    Ledezma, Carlos J; Wintermark, Max

    2009-01-01

    A multimodal CT protocol provides a comprehensive noninvasive survey of acute stroke patients with accurate demonstration of the site of arterial occlusion and its hemodynamic tissue status. It combines widespread availability with the ability to provide functional characterization of cerebral ischemia, and could potentially allow more accurate selection of candidates for acute stroke reperfusion therapy. This article discusses the individual components of multimodal CT and addresses the potential role of a combined multimodal CT stroke protocol in acute stroke therapy.

  2. Image reconstruction for brain CT slices

    Institute of Scientific and Technical Information of China (English)

    吴建明; 施鹏飞

    2004-01-01

    Different modalities in biomedical images, like CT, MRI and PET scanners, provide detailed cross-sectional views of human anatomy. This paper introduces three-dimensional brain reconstruction based on CT slices. It contains filtering, fuzzy segmentation, matching method of contours, cell array structure and image animation. Experimental results have shown its validity. The innovation is matching method of contours and fuzzy segmentation algorithm of CT slices.

  3. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  4. CT enterography: technical and interpretive pitfalls.

    Science.gov (United States)

    Barlow, John M; Goss, Brian C; Hansel, Stephanie L; Kolbe, Amy B; Rackham, Joshua L; Bruining, David H; Fletcher, Joel G

    2015-06-01

    CT enterography is a first-line test at many institutions to investigate potential small bowel disorders. While numerous articles have focused on the ability of CT enterography to diagnose and stage Crohn's disease, small bowel neoplasia, and malabsorptive or vascular disorders, this article reviews CT enterography limitations, technical and interpretive pitfalls, image review tactics, and complementary radiologic and endoscopic examinations to improve diagnostic accuracy. CT enterography limitations include its inability to demonstrate isolated mucosal abnormalities such as aphthous ulcers and its use of ionizing radiation. The most common technical pitfall of CT enterography is inadequate small bowel distention resulting from inadequate ingestion, gastric retention, or rapid small bowel transit of a large volume of neutral enteric contrast material. Additionally, segments of jejunum are frequently collapsed. Interpretive pitfalls commonly result from peristaltic contractions, transient intussusception and opaque intraluminal debris. Opaque debris is especially problematic during multiphasic CT enterography performed to identify potential small bowel sources of obscure gastrointestinal bleeding. False-negative examinations may result from inadequate radiation dose. Examinations complementary to CT enterography include small bowel follow through, enteroclysis, CT enteroclysis, MR enterography, MR enteroclysis, capsule endoscopy, and balloon-assisted endoscopy. Properly performed and accurately interpreted CT enterography contributes to the diagnosis and management of small bowel disease by itself and as a complement to other radiologic and optical small bowel imaging examinations.

  5. Pediatric CT quality management and improvement program

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B.; Chan, Frandics P.; Newman, Beverley; Fleischmann, Dominik [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States); Molvin, Lior Z. [Stanford Hospital and Clinics, Stanford, CA (United States); Wang, Jia [Stanford University, Environmental Health and Safety, Stanford, CA (United States)

    2014-10-15

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve. (orig.)

  6. Segmentation of Lung Structures in CT

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau

    (COPD) using CT scans from the Danish Lung Cancer Screening Trial (DLCST) study. We propose a fully automated lung segmentation algorithm that is based on region growing and the assumption that the lungs are of lower intensities than surrounding structures in CT. Furthermore, we also propose a post...... processing step that detects and removes esophagus regions, wrongly added by the region growing process, to improve the reliability of the lung segmentation algorithm. The proposed algorithm has been successfully applied to more than 6000 low dose CT scans from the DLCST study. Among the CT scans applied...

  7. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  8. CT evaluation of thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Hee [Insung Hospital, Chuncheon (Korea, Republic of); Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness.

  9. CT detection and aspiration of abdominal abscesses.

    Science.gov (United States)

    Haaga, J R; Alfidi, R J; Havrilla, T R; Cooperman, A M; Seidelmann, F E; Reich, N E; Weinstein, A J; Meaney, T F

    1977-03-01

    Computed tomography (CT) is effective in detecting intraabdominal abscesses. Loculations of fluid and extraluminal gas are clearly localized in relation to other organs. Of 22 abscess in this series, CT successfully detected 20; comparative information with gallium, techneticum, and ultrasound scans is presented. In addition to localizing these collections, CT can be used to guide needle aspiration and drainage procedures. Three sizes of needles were used to aspirate specimens and/or provide drainage. This was accomplished successfully in 12 of 14 CT-guided procedures.

  10. CT-based interstitial HDR brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kolotas, C.; Baltas, D.; Zamboglou, N. [Staedtische Kliniken Offenbach (Germany). Strahlenklinik

    1999-09-01

    Purpose: Development, application and evaluation of a CT-guided implantation technique and a fully CT-based treatment planning procedure for brachytherapy. Methods and Materials: A brachytherapy procedure based on CT-guided implantation technique and CT-based treatment planning has been developed and clinical evaluated. For this purpose a software system (PROMETHEUS) for the 3D reconstruction of brachytherapy catheters and patient anatomy using only CT scans has been developed. An interface for the Nucletron PLATO BPS treatment planning system for optimization and calculation of dose distribution has been devised. The planning target volume(s) are defined as sets of points using contouring tools and are used for optimization of the 3D dose distribution. Dose-volume histogram based analysis of the dose distribution (COIN analysis) enables a clinically realistic evaluation of the brachytherapy application to be made. The CT-guided implantation of catheters and the CT-based treatment planning procedure has been performed for interstitial brachytherapy and for different tumor sites in 197 patients between 1996 and 1997. Results: The accuracy of the CT reconstruction was tested using first a quality assurance phantom and second, a simulated interstitial implant of 12 needles. These were compared with the results of reconstruction using radiographs. Both methods gave comparable results with regard to accuracy, but the CT based reconstruction was faster. Clinical feasibility was proved in pre-irradiated recurrences of brain tumors, in pretreated recurrences or metastatic disease, and in breast carcinomas. The tumor volumes treated were in the range 5.1 to 2,741 cm{sup 3}. Analysis of implant quality showed a slightly significant lower COIN value for the bone implants, but no differences with respect to the planning target volume. Conclusions: The Offenbach system, incorporating the PROMETHEUS software for interstitial HDR brachytherapy has proved to be extremely valuable

  11. CT features of renal infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzer, Okan; Shirkhoda, Ali; Jafri, S. Zafar; Madrazo, Beatrice L.; Bis, Kostaki G.; Mastromatteo, James F

    2002-10-01

    Purpose: To demonstrate the different patterns of renal infarction to avoid pitfalls. To present 'flip-flop enhancement' pattern in renal infarction. Materials and methods: Retrospective review of a total of 41 renal infarction in 37 patients were done. These patients underwent initial CT and the diagnosis of renal infarction was confirmed with either follow up CT or at surgery. Results: Twenty-three patients had wedge-shaped focal infarcts, nine patients had global and five patients had multifocal infarcts of the kidneys. Cortical rim sign was seen predominantly with global infarcts. In five patients, a 'flip-flop enhancement' pattern was observed. In two patients, planned renal biopsies due to tumefactive renal lesions were cancelled because of 'flip-flop enhancement' pattern on follow up CTs. Conclusion: Although most of our cases were straightforward for the diagnosis of renal infarction, cases with tumefactive lesions and global infarctions without the well-known cortical rim sign were particularly challenging. We describe a new sign, flip-flop enhancement pattern, which we believe solidified the diagnosis of renal infarction in five of our cases. The authors recommend further investigations for association of flip-flop enhancement and renal infarction.

  12. Three-section expiratory CT

    DEFF Research Database (Denmark)

    Loeve, Martine; de Bruijne, Marleen; Hartmann, Ieneke C. J.;

    2012-01-01

    . Longitudinal follow-up was performed with three sections. All images were deidentified and randomized, and TA was scored with the Brody II system and a new quantitative system. Statistical analysis included the Wilcoxon signed rank test, calculation of Spearman and intraclass correlation coefficients, and use...... of three-section and linear mixed models.Results: For the Brody II system, the intraclass correlation coefficient for set 1 versus those for sets 2 through 7 was 0.75 versus 0.87; however, mean scores from sets 6 and 7 were significantly lower than the mean score from set 1 (P = .01 and P ..., respectively). For the quantitative system, the number of sections did not affect TA assessment (intraclass correlation coefficient range, 0.82-0.88; P > .13 for all). CT and PFT estimates were not correlated (rs = 20.19 to 0.09, P = .43-.93). No change in TA over time was found for CT or PFT (P > .16 for all...

  13. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    NARCIS (Netherlands)

    Mets, O.M.; Isgum, I.; Mol, C.P.; Gietema, H.A.; Zanen, P.; Prokop, M.; Jong, Pim A. de

    2012-01-01

    OBJECTIVES: To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. METHODS: We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3‘months. Inspiratory and expiratory low-dose CT was obtai

  14. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  15. SPECT/CT - Technical aspects and optimization possibilities; SPECT/CT - Technische Aspekte und Optimierungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W. [Klinikum Passau, Klinik fuer Nuklearmedizin, Passau (Germany)

    2012-07-15

    In contrast to positron emission tomography/computed tomography (PET/CT), the currently available single photon emission computed tomography/computed tomography (SPECT/CT) systems are very heterogeneous. On the side of the gamma cameras, dual-head systems are established, which are not very different from one manufacturer to the other. For the CT component, there are low dose tubes on the one side and flat detector-based cone beam CT and multislice-CT on the other. The CT image data can be used for anatomic correlation of suspicious findings as well as for attenuation correction of SPECT data. Attenuation correction enables on the one hand enhancement of SPECT image quality and on the other hand quantification of the radioactivity concentration becomes possible. Modern iterative reconstruction algorithms allow scatter correction and attenuation correction of SPECT data using the density values from CT. It still has to be shown to what extent attenuation-corrected whole body SPECT/CT studies will be able to improve the sensitivity of scintigraphy studies. As SPECT/CT primarily aims at morphologic correlation and not detection of additional lesions, an attempt should be made to balance the necessary anatomic information and the additional radiation exposure. Besides SPECT-guided CT all technical possibilities for dose reduction should be exhausted. (orig.) [German] Im Gegensatz zur Positronenemissionstomographie/Computertomographie (PET/CT) sind die auf dem Markt angebotenen Single-photon-emission-computed-tomography/CT(SPECT/CT)-Systeme sehr heterogen. Auf der Seite der Gammakameras sind Zweikopfsysteme etabliert, die sich bei den verschiedenen Wettbewerbern nur unwesentlich unterscheiden. Hingegen reicht bei der CT-Komponente die Palette von der einfachen Niedrigdosisroentgenroehre ueber die flachdetektorbasierte Cone-beam-CT-Technologie bis hin zum Mehrzeilenspiral-CT. Die CT-Bilddaten werden dabei zum einen zur anatomischen Korrelation funktionell auffaelliger

  16. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  17. Selective CT for PET/CT: dose reduction in Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Gelfand, Michael J.; Sharp, Susan E. [Cincinnati Children' s Hospital Medical Center, Section of Nuclear Medicine, Department of Radiology, Cincinnati, OH (United States); Palumbo, Joseph S. [Cincinnati Children' s Hospital Medical Center, Cancer and Blood Diseases Institute, Department of Pediatrics, Cincinnati, OH (United States)

    2014-08-23

    In Langerhans cell histiocytosis (LCH), FDG PET demonstrates active disease in bone. Other imaging modalities show the effects of bone destruction by LCH. To evaluate a selective CT method for reducing effective dose from FDG PET/CT in LCH, using whole-body modified attenuation correction CT at extremely low exposure settings, with repeat selective limited-volume CT at typical localization settings. Fifty-one PET/CT scans were performed in 23 LCH patients, median patient age 8.5 years (range: 1-25 years). Thirty-four were performed with modified attenuation correction CT settings, with bed positions (excluding head and neck) repeated at localization CT settings in regions with abnormal or difficult to interpret PET findings. Of 34 modified attenuation correction PET/CT scans, 10 required repeat localization CT of 1 to 3 bed positions (total: 17 bed positions). Lytic bone lesions were easily recognized at modified attenuation correction settings. Calculated average effective dose for the 34 whole-body CT scans at modified attenuation correction settings was 1.65 mSv. Average effective dose per patient for repeat imaging of 17 bed positions at localization settings was 1.19 mSv. Average total effective dose from CT for all 34 scans performed at the modified attenuation correction CT settings, including the 10 repeat localization CT scans, was 2.0 mSv. High-quality PET scans were consistently obtained with reduced FDG-administered activities of 3.7 MBq/kg (0.10 mCi/kg). In active LCH, abnormal FDG uptake was seen in all lytic bone lesions ≥9 mm, including cranial vault lesions. Substantial reduction in effective dose is possible using selective CT techniques for FDG PET/CT. (orig.)

  18. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Feng Shiting [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Law, Martin Wai-Ming [Department of Clinical Oncology, Queen Mary Hospital (Hong Kong); Huang Bingsheng [Department of Diagnostic Radiology, University of Hong Kong (Hong Kong); Ng, Sherry [Department of Clinical Oncology, Queen Mary Hospital (Hong Kong); Li Ziping; Meng Quanfei [Department of Radiology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China); Khong, Pek-Lan, E-mail: plkhong@hkucc.hku.hk [Department of Diagnostic Radiology, University of Hong Kong (Hong Kong)

    2010-11-15

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  19. Perfusion CT in acute stroke; Stellenwert der CT-Perfusion fuer die Therapie des Schlaganfalls

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, Bernd [Asklepios Klinik Altona (Germany). Radiologie und Neuroradiologie; Roether, Joachim [Asklepios Klinik Altona (Germany). Neurologische Abt.; Fiehler, Jens [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Neuroradiologische Diagnostik und Intervention; Thomalla, Goetz [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Neurologie, Kopf- und Neurozentrum

    2015-06-15

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  20. Quantitative Techniques in PET-CT Imaging

    NARCIS (Netherlands)

    Basu, Sandip; Zaidi, Habib; Holm, Soren; Alavi, Abass

    2011-01-01

    The appearance of hybrid PET/CT scanners has made quantitative whole body scanning of radioactive tracers feasible. This paper deals with the novel concepts for assessing global organ function and disease activity based on combined functional (PET) and structural (CT or MR) imaging techniques, their

  1. Reconstructing misaligned x-ray CT data

    Energy Technology Data Exchange (ETDEWEB)

    Divin, C. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-24

    Misalignment errors for x-ray computed tomography (CT) systems can manifest as artifacts and a loss of spatial and contrast resolution. To mitigate artifacts, significant effort is taken to determine the system geometry and minimizing any residual error in the system alignment. This project improved our ability to post-correct data which was acquired on a misaligned CT system.

  2. Intrahepatic arterioportal shunt: helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Quiroga, S.; Sebastia, M.C.; Moreiras, M.; Pallisa, E.; Rius, J.M.; Alvarez-Castells, A. [I. D. I. Hospital General i Universitari Vall d`Hebron, Barcelona (Spain). Servei de Radiodiagnostic

    1999-08-01

    The purpose of this study was to characterize the appearance of intrahepatic arterioportal shunts (APS) on two-phase helical CT, with emphasis on the importance of the hepatic arterial-dominant phase (HAP) to demonstrate perfusion disorders. We review eight cases of APS diagnosed by helical CT in our institution from January 1996 to March 1997 and describe the CT findings that established diagnosis. Five of them were confirmed by angiography. In seven (87.5 %) cases of APS we found early enhancement of the peripheral portal branches during the HAP of helical CT, whereas the superior mesenteric and splenic veins remained unenhanced. In five (62.5 %) cases of APS, transient, peripheral, triangular parenchymal enhancement was depicted during the HAP of helical CT; in four of these cases there was associated early enhancement of the portal branches. Helical CT can show perfusion alterations that might remain undiagnosed with conventional CT. An understanding of the hemodynamic changes that occur in APS can help in the interpretation of focal transient hepatic parenchymal enhancement and to differentiate APS from hypervascular tumors. We believe that the helical CT findings described herein are characteristic enough to suggest the diagnosis of APS. (orig.) With 3 figs., 1 tab., 16 refs.

  3. Cervical diplomyelia revealed by computed tomography (CT)

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, G.B.; Davidovits, P.; Cerisoli, M.; Giulioni, M.

    1982-05-01

    An unusual case of cervical diplomyelia diagnosed by Computed Tomography (CT) is reported. The usefulness of CT examination in the evaluation of spinal dysraphic defects is emphasized, though performed without CSF enhancement. Visualisation of spinal cord splitting in the absence of bony spicula allows the authors to differentiate between diplomyelia and diastematomyelia which have been often described by using both terms interchangeably.

  4. CT-skanninger af fossile hvaler

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Ramassamy, Benjamin Fernand Guy; Munk, Ole Lajord;

    2017-01-01

    CT-skannere er brugbare redskaber til undersøgelser af uddøde hvalarter. Dels kan skanningerne give indsigt i fossilernes indre anatomi, og dels kan de være nyttige, når konservatorerne efterfølgende skal præparere knoglerne frem. CT-skanningerne kan endvidere dokumentere knoglernes placering i...

  5. CT metrizamide myelography in intrathoracic meningocele

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Man; Woo, Seong Ku; Kim, Ok Bae; Suh, Soo Jhi [Keimyung University Medical College, Daegu (Korea, Republic of)

    1985-06-15

    Intrathoracic meningocele is a protrusion of the spinal meninges through an intervertebral foramen into the thoracic cavity. The majority occur in association with neurofibromatosis. The authors experienced a case of intrathoracic meningocele in 26 years old male patient associated with neurofibromatosis, and present conventional CT and CT metrizamide myelographic findings.

  6. CT evaluation of acetabular dysplasta in adults.

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To evaluate methods of measurement by CT and their clinical significance for acetabular dysplasia(AD) in adults. Methods: CT imaging was examined and measured in 33 adult patients with AD, compared with the normal control group of 210 adults. Results: This study showed the results of AD patients

  7. CT of schistosomal calcification of the intestine

    Energy Technology Data Exchange (ETDEWEB)

    Fataar, S.; Bassiony, H.; Satyanath, S.; Rudwan, M.; Hebbar, G.; Khalifa, A.; Cherian, M.J.

    1985-01-01

    The spectrum of schistosomal colonic calcification on abdominal radiographs has been described. The appearance on computed tomography (CT) is equally distinctive and occurs with varying degrees of genitourinary calcification. The authors have experience in three cases with the appearance on CT of intestinal calcification due to schistosomiasis.

  8. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  9. Acute gynecologic disorders in adolescents: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Tong [Soonchunhyang Univ. Cheonan Hospital/Soonchunhyang Univ. College of Medicine, Cheonan (Korea, Republic of)

    2012-09-15

    Gynecologic disorders that cause pelvic pain in adolescents include hemorrhagic ovarian cysts, rupture or torsion of ovarian cyst or tumors, hematocolpos caused by vaginal obstruction, endometriosis, cystic uterine adenomyosis, pelvic inflammatory diseases, and pelvic inclusion cyst. The use of CT for the evaluation of pelvic pain is increasing, and CT is useful if ultrasound findings are not decisive and the lesion is extensive.

  10. Reducing radiation dose in CT enterography.

    Science.gov (United States)

    Del Gaizo, Andrew J; Fletcher, Joel G; Yu, Lifeng; Paden, Robert G; Spencer, Garrett Clay; Leng, Shuai; Silva, Annelise M; Fidler, Jeff L; Silva, Alvin C; Hara, Amy K

    2013-01-01

    Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.

  11. The fibromatoses: CT-pathologic correlation.

    Science.gov (United States)

    Francis, I R; Dorovini-Zis, K; Glazer, G M; Lloyd, R V; Amendola, M A; Martel, W

    1986-11-01

    Although CT has been used in the evaluation of benign fibroblastic tumors (fibromatoses), data are lacking on radiologic-histopathologic correlation. In an attempt to explain the variable CT appearance of these lesions, a retrospective analysis was carried out of CT findings and histopathologic features in nine patients with fibromatoses. In three of four patients who had precontrast CT scans, the tumors were hyperdense relative to muscle, whereas in one patient the lesion was hypodense. The postenhancement appearance was variable. The pathologic specimens were analyzed and graded for collagen content, cellular content, tumor necrosis, and tumor vascularity. No consistent relationship could be established between the CT appearance of these lesions and their histologic appearance.

  12. Choroidal osteoma: US and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun; Park, Sang Woo [Armed Forces Kwangju Hospital, Kwangju (Korea, Republic of); Kim, Jeong Hun [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    The purpose of this study was to evaluate US and CT features of choroidal osteoma. US and CT scans of seven cases of choroidal osteoma occurring in six patients were retrospectively analyzed. We analysed US and CT findings with particular attention to the location, size, and shape of calcification associated with choroidal osteoma, and sought the possible cause of the tumor, if any. None of six patients had any possible cause related to choroidal osteoma. All of seven cases of choroidal osteoma were manifested as calcified mass which were located in the posterior wall of the eyeball near the juxtapapillary region. Calcification ranged in size from 1 to 2 cm and had curvilinear shape. Both US and CT were equally useful to evaluate choroidal osteoma. By depicting the characteristic calcification, US and CT are useful imaging modalities in evaluating choroidal osteoma.

  13. CT findings in patients with cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Konno, K. (Akita Univ. (Japan))

    1982-01-01

    Clinical findings and CT findings in 73 cases of cerebral palsy were studied. The causes of cerebral palsy were presumed to be as follows: abnormal cerebral development (36%), asphyxial delivery (34%), and immature delivery (19%), etc. CT findings were abnormal in 58% of the 73 cases, 83% of the spastic tetraplegia patients and all of the spastic hemiplegia patients showed abnormal CT findings. All the patients with spastic monoplegia presented normal CT findings. In 75% of the spastic hemiplegia cases, the CT abnormalities were due to cerebral parenchymal abnormality such as porencephaly and regional low absorption. In cases of spastic tetraplegia, cerebral parenchymal abnormality was found only in 10%. Cortical atrophy was found only in 15 of the 73 cases, whereas central atrophy was found in 36 cases.

  14. SPECT/CT and pulmonary embolism

    DEFF Research Database (Denmark)

    Mortensen, Jann; Borgwardt, Henrik Gutte

    2014-01-01

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar...... technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had...... the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume...

  15. Segmentation of Lung Structures in CT

    DEFF Research Database (Denmark)

    Lo, Pechin Chien Pau

    This thesis proposes and evaluates new algorithms for segmenting various lung structures in computed tomography (CT) images, namely the lungs, airway trees and vessel trees. The main objective of these algorithms is to facilitate a better platform for studying Chronic Obstructive Pulmonary Disease...... (COPD) using CT scans from the Danish Lung Cancer Screening Trial (DLCST) study. We propose a fully automated lung segmentation algorithm that is based on region growing and the assumption that the lungs are of lower intensities than surrounding structures in CT. Furthermore, we also propose a post...... processing step that detects and removes esophagus regions, wrongly added by the region growing process, to improve the reliability of the lung segmentation algorithm. The proposed algorithm has been successfully applied to more than 6000 low dose CT scans from the DLCST study. Among the CT scans applied...

  16. Mass preserving image registration for lung CT

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin;

    2012-01-01

    on four groups of data: 44 pairs of longitudinal inspiratory chest CT scans with small difference in lung volume; 44 pairs of longitudinal inspiratory chest CT scans with large difference in lung volume; 16 pairs of expiratory and inspiratory CT scans; and 5 pairs of images extracted at end exhale and end...... inhale phases of 4D-CT images. Registration errors, measured as the average distance between vessel tree centerlines in the matched images, are significantly lower for the proposed mass preserving image registration method in the second, third and fourth group, while there is no statistically significant......This paper presents a mass preserving image registration algorithm for lung CT images. To account for the local change in lung tissue intensity during the breathing cycle, a tissue appearance model based on the principle of preservation of total lung mass is proposed. This model is incorporated...

  17. Dynamic CT features of hepatic abscesses

    Institute of Scientific and Technical Information of China (English)

    ZOU Li-guang; CHEN Ken; LI Yan-yu; YI Xi-zhi

    2002-01-01

    Objective: To investigate the features of hepatic abscess by dynamic contrast-enhanced CT. Methods: CT films of 62 cases of hepatic abscesses were reviewed retrospectively. All the patients underwent both plain and enhanced CT scanning, and 23 of them received dynamic CT examination. Results: The dynamic phase (60~90 s), the enhancement patterns of the abscesses varied from the ring enhancement of the abscess diminished in which the hypodense ring enhanced and became isodense, or the abscess enhanced diffusely and became smaller, the colliquative necrosis area more obvious. Conclusion: Contrast enhanced CT should be used routinely in the evaluation of hepatic abscesses. The dynamic and delayed scan is necessary to diagnose atypical hepatic abscesses.

  18. Cystic thymic diseases: CT manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-09-15

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component.

  19. 新生儿缺氧缺血性脑病脑实质CT值与Apgar评分的相关性研究%Stud y on the relation between CT value of hypoxie-ischemic encephalopathy and Apgar about the newborn

    Institute of Scientific and Technical Information of China (English)

    朱裕; 陈任政; 李旭军; 曾纪莲; 刘红宣

    2015-01-01

    Objective To study on the relation between the CT values on the newborn hypoxie-ischemic encephal-opathy (HIE) and Apgar score, which can provide reference value on treatment of the newborn and predict the prognosis. Methods Randomly sampled 62 newborn with HIE had Apgar score in our hospital and to analyze their 64 multi-detector helical CT imaging, and used the statistical software to find out the relation between the CT value and Apgar score. Results ① White matter of premature infant was more sensitive than that of mature infant, while gray matter of mature infant was more sensitive than that of premature infant. The CT value was more sensitive than Apgar score. ② The Apgar of premature infant or mature infant and the difference between gray matter and the CT value of Pons was positive corr-elation (r=0.675).③CT value was more sensitive than Apgar score. Conclusion CT examination can be more sensitive on diagnosis of HIE exactly and quickly. In addition, the report of CT examination can tell the degree of brain damage by providing specific data.%目的:探讨新生儿缺氧缺血性脑病(HIE)脑实质CT值与Apgar评分的相关性,为患儿的治疗及预后提供参考数据。方法随机抽取我院62例经过Apgar评分的HIE患儿,通过回顾性分析64排螺旋CT扫描的图像,选取特定的部位,测量CT值,利用统计软件,发现Apgar评分与CT值之间的联系。结果①早产儿脑白质损害较足月儿更敏感,足月儿脑灰质损害较早产儿更敏感;②出生10 min早产儿、足月儿Apgar评分分别和灰质与桥脑CT值之差(D)呈正相关(r=0.675);③CT值较Apgar评分更敏感。结论 CT检查能及时、准确、快捷诊断HIE,并能判断脑损害的严重程度,且敏感性高于临床Apgar评分,可以提供客观的具体参考数据。

  20. Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT.

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M; Kinahan, Paul E

    2010-01-29

    We present an analysis of the effects of ultra-low dose X-ray computerized tomography (CT) based attenuation correction for positron emission tomography (PET). By ultra low dose we mean less than approximately 5 mAs or 0.5 mSv total effective whole body dose. The motivation is the increased interest in using respiratory motion information acquired during the CT scan for both phase-matched CT-based attenuation correction and for motion estimation. Since longer duration CT scans are desired, radiation dose to the patient can be a limiting factor. In this study we evaluate the impact of reducing photon flux rates in the CT data on the reconstructed PET image by using the CATSIM simulation tool for the CT component and the ASIM simulation tool for the PET component. The CT simulation includes effects of the x-ray tube spectra, beam conditioning, bowtie filter, detector noise, and bean hardening correction. The PET simulation includes the effect of attenuation and photon counting. Noise and bias in the PET image were evaluated from multiple realizations of test objects. We show that techniques can be used to significantly reduce the mAs needed for CT based attenuation correction if the CT is not used for diagnostic purposes. The limiting factor, however, is not the noise in the CT image but rather the bias introduced by CT sinogram elements with no detected flux. These results constrain the methods that can be used to lower CT dose in a manner suitable for attenuation correction of PET data. We conclude that ultra-low-dose CT for attenuation correction of PET data is feasible with current PET/CT scanners.

  1. Staging of cutaneous malignant melanoma by CT; CT-Staging kutaner maligner Melanome

    Energy Technology Data Exchange (ETDEWEB)

    Hoffend, J. [Klinikum der Stadt Ludwigshafen gGmbH, Zentralinstitut fuer diagnostische und interventionelle Radiologie, Ludwigshafen (Germany)

    2015-01-30

    Malignant melanomas are a challenge in radiological imaging diagnostics as they may metastasize into every organ and tissue. Cross-sectional imaging, in particular positron emission tomography computed tomography (PET/CT) and whole body magnetic resonance imaging (MRI), are considered the standards in the staging of melanomas. Because of its excellent availability CT, however, remains a widely employed staging modality. Familiarity with the manifold CT morphology of metastasized melanomas as it is described here is essential when interpreting dedicated CT and in addition useful when interpreting PET/CT results. In individual cases CT can assist in the detection of transient metastases. In the detection of locoregional lymph node metastases CT has a median sensitivity and specificity in meta-analyses of at best 61 % and 97 %, respectively, which is inferior to the performance of ultrasound (96 % and 99 %, respectively). According to meta-analyses, in the assessment of systemic tumor spread CT can detect the majority of metastases with a sensitivity and specificity of 51-63 % and 69-78 %, respectively, which is inferior to MRI and PET/CT. Therefore, if an exact staging is required for critical management decisions, MRI or PET/CT should be employed whenever possible. (orig.) [German] Maligne Melanome koennen in praktisch jedes Organ und Gewebe metastasieren und stellen daher eine Herausforderung fuer die radiologische Diagnostik dar. Schnittbildverfahren, bevorzugt PET/CT und MRT, werden heute als Standard in der Ausbreitungsdiagnostik von Melanomen angesehen. Wegen ihrer ubiquitaeren Verfuegbarkeit bleibt jedoch die CT ein vielfach genutztes Staginginstrument. Die Kenntnis der vielfaeltigen CT-Morphologie von Melanommetastasen, wie sie in diesem Beitrag beschrieben wird, ist ueber die dedizierte CT hinaus uebertragbar auf die von der aktuellen Leitlinie bevorzugte Bildgebung mit der PET/CT. Im Einzelfall kann die CT hilfreich bei der Detektion von In

  2. Correlation Study between Spiral CT Perfusion Imaging and Angiogenesis in Esophageal Carcinoma%食管癌螺旋CT灌注成像与肿瘤血管生成的相关性研究

    Institute of Scientific and Technical Information of China (English)

    宋涛; 黎海亮; 窦新民; 吴越; 刘予东

    2011-01-01

    目的 探讨食管癌螺旋CT灌注成像与肿瘤血管生成的相关性.资料与方法 对50例食管癌患者行多排螺旋CT灌注扫描,分析食管癌CT灌注成像参数血容量(BV)、血流量(BF)、平均通过时间(MTT)、表面通透性(PS)与微血管密度(MVD)及血管内皮生长因子(VEGF)表达之间的关系.结果 50例食管癌中,VEGF阳性表达率为62%(31/50),阴性表达率为38%(19/50),MVD值在两组间的差异具有统计学意义(P<0.05);BF值与MVD呈正相关(P<0.05),BV及PS值与MVD呈显著性正相关(P<0.01),MTT值与MVD无相关性(P>0.05);PS值与VEGF表达呈正相关(P<0.05),BF、BV及MTT与VEGF表达无相关性(P>0.05).结论 食管癌CT灌注成像能够在一定程度上反映活体的肿瘤血管生成状况.%Objective To evaluate the correlation between spiral CT perfusion imaging and angiogenesis in esophageal carcinoma. Materials and Methods Multi-detector spiral CT perfusion scan was performed in 50 patients with esophageal carcinoma. The relationship of the CT perfusion imaging parameters, including blood volume ( BV) , blood flow( BF), mean transit time( MTT) ,and permeability surface( PS),with MVD and expressions of VEGF were analyzed. Results In 50 cases,the VEGF positive expression rate was 62% (31/50),and the negative expression rate was 38% ( 19/50). The mean MVD of VEGF-positive group were significantly higher than those of negative group ( P 0.05). The PS value and VEGF expression were positively correlated( P 0.05 ). Conclusion CT perfusion parameters can reflect not only the angiogenesis of esophageal carcinoma of the MVD,but also the expression of VEGF,indicating that CT perfusion parameters can be used as an assessment of tumor angiogenesis in vivo.

  3. CT in three cases of syringomyelia

    Energy Technology Data Exchange (ETDEWEB)

    Ugawa, Yoshikazu; Sakuta, Manabu (Japan Red Cross Medical Center, Tokyo (Japan)); Yagishita, Akira; Inoue, Kiyoharu

    1983-08-01

    We presented the results of our experience with metrizamide computed tomographic myelography (MCTM) and myelography in three cases of syringomyelia. In case 1, MCTM revealed Chiari malformation, even though this malformation was not clear in the myelography. In case 3, Chiari malformation was apparent in MCTM and in the myelography. In case 1, CT of the spinal cord without enhancement (plain CT) showed a syrinx in the cervical spinal cord, and MCTM made the syrinx clearer with enhancement. MCTM also demonstrated a cavity at the levels of Th/sub 6/ and L/sub 1/ of the vertebra. In case 2, a syrinx was disclosed in MCTM, in spite of normal myelography. In case 3, myelography demonstrated a spinal cord swelling. MCTM made a syrinx less clear than plain CT. Not only MCTM but also plain CT is an excellent method for the recognition of syringomyelia. The non-invasive plain CT is the first choice of the examinations in cases with syrinogomyelia, because MCTM may make a syrinx obscure. CT and MCTM have to be performed at many levels of the spinal cord in case with syringomyelia. CT or MCTM may demonstrate a syrinx or a cavity at the levels of the spinal cord, where no syrinx is suspected to exist by clinical features, as well as at the levels appearing normal in the myelography.

  4. Clival chordoma; CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Si Kyung; Han, Chun Hwan; Lee, Moon Ok; Kim, Mie Young; Yi, Jeong Geun; Lee, Joo Hyuk [Kang Nam General Hospital Pubic Corporation, Seoul (Korea, Republic of); Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1993-07-15

    A retrospectively analysis of CT and MR findings was performed in five patients with histologically proved chordoma including one with chondroid chordoma. All tumors were mostly isodense to gray matter on unenhanced CT, and the single intensities were iso or low and high on T1 and T2-weighted MR images, respectively. The tumors had an increase in their density on enhanced CT and MR in four patients, but a chondroid chordoma was poorly enhanced after injection of contrast medicum on CT. Four tumors contained calcifications in CT images and two lesionsshowed hemorrhage in MR images. Cavenous sinus was involved in all patients, and brain stem and basilar artery were compressed by the tumors in three cases. Pituitary gland was only displaced upward in three patients. Clivus was destroyed in all cases, and sella turcica and sphenoid bone were involved in three patients. CT is better than MR in demonstrating calcifications and bone destruction. In defining the extension of tumor, MR appears to be superior to CT in evaluation of the relationship between the tumor and the surrounding structures.

  5. Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas

    Institute of Scientific and Technical Information of China (English)

    Dan Wang; Xiao-Er Wei; Lei Yan; Yu-Zhen Zhang; Wen-Bin Li

    2011-01-01

    AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic pancreas, as confirmed by clinical pathology and immunohistochemistry in the Sixth Affiliated People's Hospital of Shanghai Jiao Tong University, Shanghai, China, were included. Non-enhanced CT and enhanced CT scanning were performed, and the resulting images were reviewed and analyzed using.three-dimensional post-processing software, including CTVE. RESULTS: Four males and two females were enrolled. Several heterotopic pancreas sites were involved; three occurred in the stomach, including the gastric antrum (n = 2) and lesser curvature (n = 1), and two were in the duodenal bulb. Only one case of heterotopic pancreas lesion occurred in the mesentery. Four cases had a solid yet soft tissue density that had a homogeneous pattern when viewed by enhanced CT. Additionally, their CT values were similar to that of the pancreas. The ducts of the heterotopic pancreas tissue, one of the characteristic CT features of heterotopic pancreas tissue, were detected in the CT images of two patients. CTVE images showed normal mucosa around the tissue, which is also an important indicator of a heterotopic pancreas. However, none of the CTVE images showed the typical signs of central dimpling or umbilication.CONCLUSION: CT, enhanced CT and CTVE techniques provide useful information about the location, growth pattern, vascularity, and condition of the gastrointestinal wall around heterotopic pancreatic tissue.

  6. Small-animal CT: Its difference from, and impact on, clinical CT

    Science.gov (United States)

    Ritman, Erik L.

    2007-10-01

    For whole-body computed tomography (CT) images of small rodents, a voxel resolution of at least 10 -3 mm 3 is needed for scale-equivalence to that currently achieved in clinical CT scanners (˜1 mm 3) in adult humans. These "mini-CT" images generally require minutes rather than seconds to complete a scan. The radiation exposure resulting from these mini-CT scans, while higher than clinical CT scans, is below the level resulting in acute tissue damage. Hence, these scans are useful for performing clinical-type diagnostic and monitoring scans for animal models of disease and their response to treatment. "Micro-CT", with voxel size pathological accumulations of metals such as Fe and Ca, which occur in the arterial wall following hemorrhage or tissue damage. Micro-CT can also be used as a test bed for exploring the utility of several modes of X-ray image formation, such as the use of dual-energy X-ray subtraction, X-ray scatter, phase delay and refraction-based imaging for increasing the contrast amongst soft tissue components. With the recent commercial availability of high speed, multi-slice CT scanners which can be operated in dual-energy mode, some of these micro-CT scanner capabilities and insights are becoming implementable in those CT scanners. As a result, the potential diagnostic spectrum that can be addressed with those scanners is broadened considerably.

  7. Analysis of carotid artery plaque and wall boundaries on CT images by using a semi-automatic method based on level set model

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Sannia, Stefano; Ledda, Giuseppe [University of Cagliari - Azienda Ospedaliero Universitaria di Cagliari, Department of Radiology, Monserrato, Cagliari (Italy); Gao, Hao [University of Strathclyde, Signal Processing Centre for Excellence in Signal and Image Processing, Department of Electronic and Electrical Engineering, Glasgow (United Kingdom); Acharya, U.R. [Ngee Ann Polytechnic University, Department of Electronics and Computer Engineering, Clementi (Singapore); Suri, Jasjit S. [Biomedical Technologies Inc., Denver, CO (United States); Idaho State University (Aff.), Pocatello, ID (United States)

    2012-11-15

    The purpose of this study was to evaluate the potentialities of a semi-automated technique in the detection and measurement of the carotid artery plaque. Twenty-two consecutive patients (18 males, 4 females; mean age 62 years) examined with MDCTA from January 2011 to March 2011 were included in this retrospective study. Carotid arteries are examined with a 16-multi-detector-row CT system, and for each patient, the most diseased carotid was selected. In the first phase, the carotid plaque was identified and one experienced radiologist manually traced the inner and outer boundaries by using polyline and radial distance method (PDM and RDM, respectively). In the second phase, the carotid inner and outer boundaries were traced with an automated algorithm: level-set-method (LSM). Data were compared by using Pearson rho correlation, Bland-Altman, and regression. A total of 715 slices were analyzed. The mean thickness of the plaque using the reference PDM was 1.86 mm whereas using the LSM-PDM was 1.96 mm; using the reference RDM was 2.06 mm whereas using the LSM-RDM was 2.03 mm. The correlation values between the references, the LSM, the PDM and the RDM were 0.8428, 0.9921, 0.745 and 0.6425. Bland-Altman demonstrated a very good agreement in particular with the RDM method. Results of our study indicate that LSM method can automatically measure the thickness of the plaque and that the best results are obtained with the RDM. Our results suggest that advanced computer-based algorithms can identify and trace the plaque boundaries like an experienced human reader. (orig.)

  8. Hepatic CT image query using Gabor features

    Institute of Scientific and Technical Information of China (English)

    Chenguang Zhao(赵晨光); Hongyan Cheng(程红岩); Tiange Zhuang(庄天戈)

    2004-01-01

    A retrieval scheme for liver computerize tomography (CT) images based on Gabor texture is presented.For each hepatic CT image, we manually delineate abnormal regions within liver area. Then, a continuous Gabor transform is utilized to analyze the texture of the pathology bearing region and extract the corresponding feature vectors. For a given sample image, we compare its feature vector with those of other images. Similar images with the highest rank are retrieved. In experiments, 45 liver CT images are collected, and the effectiveness of Gabor texture for content based retrieval is verified.

  9. CT in childhood allergic bronchopulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Shah, A.; Bhagat, R.; Panchal, N. (Delhi Univ. (India). Vallabhabhai Patel Chest Inst.); Pant, C.S. (Institute of Nuclear Medicine and Allied Sciences, Delhi (India). Imaging Div.)

    1992-06-01

    CT of the thorax done during acute severe asthma in two paediatric patients demonstrated central bronchiectasis, a sine qua non for the diagnosis of allergic bronchopulmonary aspergillosis. Bronchography, regarded as the gold standard, was done subsequently on recovery. A comparative segmental analysis revealed that CT was able to identify immediately 24 of 27 segments which showed central bronchiectasis on bronchography. Early diagnosis with the aid of CT enabled immediate intervention which may have helped to prevent further lung damage in the paediatric patients. (orig.).

  10. CT scan of bacterial and aseptic meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Saiwai, Shigeo; Tamaoka, Koichi (Kobe Central Municipal Hospital (Japan))

    1983-01-01

    CT scans of the patients with aseptic and bacterial meningitis were reviewed and compared to previous reports. In aseptic meningitis, no abnormal CT findings were observed. In bacterial meningitis, CT findings were ventricular dilatation, subdural fluid collection, parenchymal low density, intracerebral hematoma and meningeal enhancement after contrast injection. Three patients among 48 suffered from status epileptics during the course of the illness. All of the 3 patients developed parenchymal inhomogeneous low density and progressive ventricular dilatation which did not improve after ventricular peritoneal shunt surgery. We believe that these changes are most likely due to hypoxic hypoxemia during epileptic seizure and meningitis itself seems to play a little role.

  11. Doses metrics and patient age in CT.

    Science.gov (United States)

    Huda, Walter; Tipnis, Sameer V

    2016-03-01

    The aim of this study was to investigate how effective dose and size-specific dose estimate (SSDE) change with patient age (size) for routine head and abdominal/pelvic CT examinations. Heads and abdomens of patients were modelled as a mass-equivalent cylinder of water corresponding to the patient 'effective diameter'. Head CT scans were performed at CTDIvol(S) of 40 mGy, and abdominal CT scans were performed at CTDIvol(L) of 10 mGy. Values of SSDE were obtained using conversion factors in AAPM Task Group Report 204. Age-specific scan lengths for head and abdominal CT scans obtained from the authors' clinical practice were used to estimate the dose-length product for each CT examination. Effective doses were calculated from previously published age- and sex-specific E/DLP conversion factors, based on ICRP 103 organ-weighting factors. For head CT examinations, the scan length increased from 15 cm in a newborn to 20 cm in adults, and for an abdominal/pelvic CT, the scan length increased from 20 cm in a newborn to 45 cm in adults. For head CT scans, SSDE ranged from 37.2 mGy in adults to 48.8 mGy in a newborn, an increase of 31 %. The corresponding head CT effective doses range from 1.4 mSv in adults to 5.2 mSv in a newborn, an increase of 270 %. For abdomen CT scans, SSDE ranged from 13.7 mGy in adults to 23.0 mGy in a newborn, an increase of 68 %. The corresponding abdominal CT effective doses ranged from 6.3 mSv in adults to 15.4 mSv in a newborn, an increase of 140 %. SSDE increases much less than effective dose in paediatric patients compared with adults because it does not account for scan length or scattered radiation. Size- and age-specific effective doses better quantify the total radiation received by patients in CT by explicitly accounting for all organ doses, as well as their relative radio sensitivity.

  12. Basics principles of flat detector computed tomography (FD-CT); Grundlagen der Flachdetektor-CT (FD-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Kyriakou, Y.; Struffert, T.; Doerfler, A.; Kalender, W.A. [Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany)

    2009-09-15

    Flat detectors (FDs) have been developed for use in radiography and fluoroscopy to replace standard X-ray film, film-screen combinations and image intensifiers (II). In comparison to X-ray film and II, FD technology offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. FDCT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. Additionally, the introduction of FD technology was a milestone for soft-tissue CT imaging in the interventional suite which was not possible with II systems in the past. This review focuses on technical and performance issues of FD technology and its wide range of applications for CT imaging. FDCT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations, but it has already proven unique for a number of dedicated CT applications offering distinct practical advantages, above all the availability of immediate CT imaging during an intervention. (orig.) [German] Flachdetektoren (FD) sind fuer die Anwendung in der Radiographie und Fluoroskopie entwickelt worden, um die damaligen Standards - Film-Folien-Kombinationen (FFK) und Bildverstaerker (BV) - zu ersetzen. Im Vergleich zu FFK und BV bietet die FD-Technologie eine hoehere Dynamik, Verzerrungsfreiheit und eine gesteigerte Dosiseffizienz. Weitere Vorteile sind die Anfertigung Serienaufnahmen, eine sofortige Digitalausgabe und eine kompakte Bauweise. Dies legt auch eine Anwendung von Flachdetektoren in der Computertomographie (CT) nahe. Inzwischen ist die FD-CT weitgehend in der interventionellen und intraoperativen Bildgebung etabliert - meist als C-Bogen-System. Die FD-Technologie hat erstmals die Weichteilbildgebung in der interventionellen Suite ermoeglicht, was mit BV-Systemen nicht moeglich war. Diese

  13. Diverticular disease in CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lefere, P.; Gryspeerdt, S.; Baekelandt, M.; Holsbeeck, B. van [Dept. of Radiology, Roeselare (Belgium); Dewyspelaere, J. [Dept. of Gastroenterology, Roeselare (Belgium)

    2003-12-01

    The aim of this study was to evaluate findings on CT colonography (CTC) in patients with diverticular disease. In a retrospective analysis of 160 consecutive patients, who underwent CTC and conventional colonoscopy (CC), patients with diverticular disease were retrieved. The CTC images were compared with CC and, if possible, with pathology. Findings on both 2D and 3D images are illustrated with emphasis on diagnostic problems and the possible solutions to overcome these problems. Several aspects of diverticulosis were detected: prediverticulosis (3%); global (55.6%); and focal wall thickening (4%) caused by thickened haustral folds, fibrosis, inflammation and adenocarcinoma; diverticula (52%); pseudopolypoid lesions caused by diverticular fecaliths (39%); inverted diverticula (1.2%); and mucosal prolapse (0.6%). Solutions to overcome pitfalls are described as abdominal windowing, content of the pseudopolypoid lesion, comparison of 2D and 3D images, prone-supine imaging and the aspect of the pericolic fat. In this series there were equivocal findings in case of mucosal prolapse (0.6%) and focal wall thickening (4%). Diverticulosis is a challenge for CTC to avoid false-positive diagnosis of polypoid and tumoral disease. Knowledge of possible false causes of polypoid disease and comparison of 2D and 3D images are necessary to avoid false-positive diagnosis. In case of equivocal findings additional conventional colonoscopy should be advised whenever a clinically significant lesion ({>=}1 cm) is suspected. (orig.)

  14. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  15. CT thermometry for cone-beam CT guided ablation

    Science.gov (United States)

    DeStefano, Zachary; Abi-Jaoudeh, Nadine; Li, Ming; Wood, Bradford J.; Summers, Ronald M.; Yao, Jianhua

    2016-03-01

    Monitoring temperature during a cone-beam CT (CBCT) guided ablation procedure is important for prevention of over-treatment and under-treatment. In order to accomplish ideal temperature monitoring, a thermometry map must be generated. Previously, this was attempted using CBCT scans of a pig shoulder undergoing ablation.1 We are extending this work by using CBCT scans of real patients and incorporating more processing steps. We register the scans before comparing them due to the movement and deformation of organs. We then automatically locate the needle tip and the ablation zone. We employ a robust change metric due to image noise and artifacts. This change metric takes windows around each pixel and uses an equation inspired by Time Delay Analysis to calculate the error between windows with the assumption that there is an ideal spatial offset. Once the change map is generated, we correlate change data with measured temperature data at the key points in the region. This allows us to transform our change map into a thermal map. This thermal map is then able to provide an estimate as to the size and temperature of the ablation zone. We evaluated our procedure on a data set of 12 patients who had a total of 24 ablation procedures performed. We were able to generate reasonable thermal maps with varying degrees of accuracy. The average error ranged from 2.7 to 16.2 degrees Celsius. In addition to providing estimates of the size of the ablation zone for surgical guidance, 3D visualizations of the ablation zone and needle are also produced.

  16. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  17. SPECT/CT in pediatric patient management

    Energy Technology Data Exchange (ETDEWEB)

    Nadel, Helen R. [British Columbia Children' s Hospital, University of British Columbia, Pediatric Radiologist and Nuclear Medicine Physician, Division of Nuclear Medicine Department of Radiology, Vancouver, British Columbia (Canada)

    2014-05-15

    Hybrid SPECT/CT imaging is becoming the standard of care in pediatric imaging. Indications are mainly for oncologic imaging including mIBG scintigraphy for neuroblastoma and I-123 post surgical imaging of children with thyroid carcinoma, bone scintigraphy for back pain, children referred from sports medicine and neurodevelopmentally delayed children presenting with pain symptoms. The studies provide improved diagnostic accuracy, and oncologic imaging that includes optimized CT as part of the SPECT/CT study may decrease the number of studies and sedation procedures an individual child may need. The studies, however, must be tailored on an individual basis as the addition of the CT study can increase exposure to the child and should only be performed after appropriate justification and with adherence to optimized low dose pediatric protocols. (orig.)

  18. CT of uterine cervical myeloma: case report.

    Science.gov (United States)

    Salomon, C G; Posniak, H V; Pyle, J M

    1992-01-01

    Myelomatous involvement of the uterine cervix is rare and, to our knowledge, has not been reported previously in the radiologic literature. This report describes the computed tomographic (CT) findings and reviews differential diagnostic considerations.

  19. Benign mediastinal cysts: pointed appearance on CT.

    Science.gov (United States)

    Demos, T C; Budorick, N E; Posniak, H V

    1989-01-01

    A case of bronchogenic cyst and two cases of pericardial cysts are presented. Our report illustrates the diagnostic utility of a pointed contour and the dependence of contour on position on CT in establishing the cystic nature of mediastinal mass.

  20. Contextual Analysis of CT Scanned Pig Carcasses

    DEFF Research Database (Denmark)

    Lyckegaard, Allan; Larsen, Rasmus; Christensen, Lars Bager;

    2006-01-01

    Knowledge of the weight of tissue types in pig carcasses is generally only available after manual dissection. The use of computed tomography (CT) has demonstrated to be a promising approach to gain knowledge on the lean meat weight (Romvari, 2005), but less effort has been put into gaining...... knowledge about the weight of other tissue types from CT. Knowing the weight of individual tissue types will directly give access to other measures such as the weight of the carcass and the Lean Meat Percentage (LMP). Until now, most analyses of CT scans have been based on the Hounsfield spectra that does...... not consider the spatial context in CT scan. Applying contextual methods from the field of image analysis we hope to make a virtual dissection of pig carcasses....

  1. Computed Tomography (CT) Perfusion in Abdominal Cancer

    DEFF Research Database (Denmark)

    Hansen, Martin Lundsgaard; Norling, Rikke; Lauridsen, Carsten;

    2013-01-01

    on the market today based on different perfusion algorithms. However, there is no consensus on which protocol and algorithm to use for specific organs. In this article, the authors give an introduction to CT perfusion in abdominal imaging introducing technical aspects for calculation of perfusion parameters......Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed...... table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique...

  2. CT diagnosis of parotid gland tumor

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, T.; Tomoda, K.; Amano, H. (Kansai Medical School, Moriguchi, Osaka (Japan))

    1980-12-01

    Computed Tomography (CT) was supplementary and effectively employed for diagnosis of parotid gland tumors in 33 patients. The usefulness of this technique for determining of location of tumor and for differential diagnosis was investigated. The results were as follows: 1. The depth of tumor expansion into the parapharyngeal space was clearly evaluated by CT, 2. It may be assumed that a tumor locates in the superficial lobe, if it appears outside a line drawn between the mastoid process and the mandibule. 3. If the margin of tumor appears irregular, and its content is heterogenous, diagnosis of a high-grade maligancy will be made. CT is of limited usefulness in diagnosing low-grade malignancy. 4. Clear and low density of a tumor shown in CT can be suggestive of a cyst.

  3. MRI and CT patterns of neurocysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodiek, S.O.; Rupp, N.; Einsiedel, H. von

    1987-05-01

    MRI and CT manifestations were studied in five cases of neurocysticercosis. As demonstrated by long-term follow-ups the disease usually causes multiple lesions the morphology of which depends on the life cycle of the parasite. Tissue lesions consist of three main types: 1) vital cysticerci, 2) inflammatory parenchymatous reactions following degenerating cysts and 3) calcified granulomas. MRI provides all information that is given by CT except for small calcifications which are usually missed. Morphological details of vital cysticerci like cysts wall and scolex are better outlined by MRI. When i.v. contrast medium is applied, it leads to nodular or annular enhancement of inflamed tissue. The sensitivity of MRI towards edema caused by parasite exceeds that of CT by several weeks. CT and MRI are complementary methods providing at the present time the highest degree of specificity in diagnosing neurocysticercosis.

  4. FDG PET/CT in cancer

    DEFF Research Database (Denmark)

    Petersen, Henrik; Holdgaard, Paw Christian; Madsen, Poul Henning

    2016-01-01

    use of PET/CT in the RSD with these recommendations. This article summarizes the results. METHODS: A Work Group appointed a professional Subgroup which made Clinician Groups conduct literature reviews on six selected cancers responsible for 5,768 (62.6 %) of 9,213 PET/CT scans in the RSD in 2012......-recommendable" indications, respectively. RESULTS: Of 11,729 citations, 1,729 were considered for review, and 204 were included. The evidence suggested usefulness of PET/CT in lung, lymphoma, melanoma, head and neck, and colorectal cancers, whereas evidence was sparse in gynaecological cancers. The agreement between actual...... use of PET/CT and literature-based recommendations was high in the first five mentioned cancers in that 96.2 % of scans were made for grade A or B indications versus only 22.2 % in gynaecological cancers. CONCLUSION: Evidence-based usefulness was reported in five of six selected cancers; evidence...

  5. 应用颅脑CT血管成像联合CT灌注成像诊断后循环缺血的临床价值分析%Value of Cerebral CT angiography and CT perfusion imaging to diagnose posterior circulation ischemia

    Institute of Scientific and Technical Information of China (English)

    王淑敏; 王伟; 宋义周; 郑丽平; 梁文娜

    2014-01-01

    .Method Collect the clinical data of 30 patients with posterior circulation ischemia and 30 cases of healthy people, at the same time, to exam CTA and CTPI with the application of 64 rows of 128 slice spiral CT. Result 30 cases of PCI were found on CTP maps of abnormal perfusion areas a total of 27 cases, found abnormal perfusion area corresponding to the clinical symptoms of 27 cases, 22 cases was found in the CBF diagram, While only 14 cases in the CBV char, the other 3 cases in all perfusion parameter maps were not found abnormal perfusion areas. The case group of ipsilateral and contralateral average MTT and mean CBF had a statistically significant difference (P 0.05). PCI group of vertebrobasilar artery stenosis ratio were significantly increased (P<0.01), the number of cases of vertebrobasilar artery expanded and vertebral artery hypoplasia was significantly increased (P<0.05). Conclusion CTA combined with CTPI can clearly display the circulatory system and brain blood supply, is to determine the cause of posterior circulation ischemia and ischemic severity is an effective and reliable means of inspection.

  6. CT Manifestations of Sigmoid Volvulus%乙状结肠扭转的CT表现

    Institute of Scientific and Technical Information of China (English)

    李海风; 李世宽; 周岩冰; 彭新刚; 李元博; 赵东升

    2013-01-01

    目的:乙状结肠扭转既往主要依靠腹部平片进行诊断,但腹部平片具有局限性,容易误诊、漏诊,CT可以弥补腹平片不足.探讨乙状结肠扭转的CT征象,以提高其术前诊断水平.方法:回顾性分析手术中证实为乙状结肠扭转的23例患者,分析其腹部CT扫描图和横断面扫描特征,最后总结乙状结肠扭转的CT影像学特征.结果:在CT定位像上,最敏感的表现是扩张的乙状结肠倒U征(21/23,91%),不成比例乙状结肠扩张(19/23,83%),其次为咖啡豆征(17/23,74%),Y征(12/23,52%).在横断面扫描上,最敏感的是不成比例的乙状结肠扩张(21/23,91%)和圆腹征(20/23,87%),其次为近端结肠扩张(15/23,65%),漩涡征(15/23,65%),鸟嘴征(13/23,57%).在CT定位像和横断面扫描上,典型的乙状结肠扭转影像表现分别占57%(13/23)和83%(19/23).在定位像上,咖啡豆征与Y征在显著相关(p<0.05).横断面扫描上肠管损害的CT征象与临床肠管损害显著相关(P<0.05).结论:在定位像上,乙状结肠扭转的主要影像学表现为倒U征,特征性表现为Y征;在横断面扫描上,主要影像学表现为不成比例的乙状结肠扩张,特征性表现为漩涡征和鸟嘴征.多排螺旋CT是诊断乙状结肠扭转的可靠检查方法,具有重要的临床应用价值.%Objective:Previous imaging diagnosis of Sigmoid volvulus mainly depended on abdominal X-ray plain film,but it have many disadvanteges such as limitations,easily misdiagnosed and misdiagnosis.And CT can make up for these drawbacks.To discuss the imaging characteristics of sigmoid volvulus on Multi-detector CT to improve the preoperative diagnostic accuracy of CT in patients with sigmoid volvulus.Methods:We retrospectively reviewed 23 cases of sigmoid volvulus confirmed at surgery,and then analyzed the signs of abdominal CT scanograms and cross-sectional images.Finally,we summarized CT images characteristics of sigmoid volvulus

  7. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  8. Clinical and CT findings in appendiceal diverticulitis.

    Science.gov (United States)

    Patil, Abhijit Y; Levine, Marc S; Grujic, Edina; Goren, Robert A

    2014-01-01

    Appendiceal diverticulitis is a rare pathologic entity that is difficult to diagnose on clinical grounds because of an indolent course and atypical presenting symptoms. However, the characteristic computed tomographic (CT) features should suggest the correct diagnosis, and an appendectomy should be performed. Despite its rarity, radiologists should be aware of this condition and the findings on CT because of the higher risk of perforation than in appendicitis and the potential association with appendiceal neoplasms.

  9. Spiral CT colonography in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Tarjan, Zsolt E-mail: tarjan@radi.sote.hu; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K

    2000-09-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease.

  10. CT scan findings in cerebral paragonimiasis

    Energy Technology Data Exchange (ETDEWEB)

    Udaka, Fukashi; Okuda, Bungo; Okada, Masako; Okae, Shunji; Kameyama, Masakuni (Chikamori Hospital, Kochi (Japan))

    1982-12-01

    Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies.

  11. Juvenile ossifying fibroma: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Khoury, Nabil J.; Naffaa, Lena N.; Haddad, Maurice C. [Department of Diagnostic Radiology, American University of Beirut Medical Center, P.O. Box 113-6044, Beirut (Lebanon); Shabb, Nina S. [Department of Pathology, American University of Beirut - Medical Center, P.O. Box 113-6044, Beirut (Lebanon)

    2002-07-01

    We describe the CT findings in four patients and the MR imaging in one patient with juvenile ossifying fibroma. Three lesions involved the maxillary sinus and extended to the surrounding structures; one lesion was confined to the maxillary bone. CT scan revealed well-defined, expansile lesions with variable amount of calcifications. On MRI one lesion had intermediate signal intensity with significant contrast enhancement. (orig.)

  12. Omental fibroma: CT and US findings

    Energy Technology Data Exchange (ETDEWEB)

    Paksoy, Y.; Acikgoezoglu, S.; Oedev, K. [Department of Radiology, Selcuk Univ., Konya (Turkey); Sahin, M. [Department of General Surgery, Selcuk Univ., Konya (Turkey); Oemeroglu, E. [Department of Pathology, Selcuk Univ., Konya (Turkey)

    1998-10-01

    The US, CT, and X-ray findings in a patient with omental fibroma of the lesser omentum are described. Ultrasound showed a solid mass with cystic areas in the central region. At CT the lesion showed peripheral enhancement and central hypodensity. On X-ray studies with barium, there was border distortion in the lesser curvature of the stomach. The mass was resected surgically. A pathologic diagnosis of fibroma was confirmed. (orig.) (orig.) With 5 figs., 8 refs.

  13. Mucinous cystadenoma of the appendix: CT findings

    Institute of Scientific and Technical Information of China (English)

    ZHOU Mei-ling; YAN Fu-hua; XU Peng-ju; ZHANG Li-jun; LI Qing-hai; JI Yuan

    2006-01-01

    @@ Appendiceal mucinous cystadenoma (AMC) is an uncommon disease. The clinical symptoms are non-specific, thus the preoperative diagnosis is very difficult. The importance of recognizing this condition lies in preventing spillage during surgery. At present,the widespread use of computed tomography (CT)for evaluating abdominal disease has increased the detection rate and diagnostic accuracy for AMC.Here, we report the CT appearance of 4histologically proven AMCs.

  14. CT enterography of pediatric Crohn disease

    Energy Technology Data Exchange (ETDEWEB)

    Dillman, Jonathan R.; Strouse, Peter J. [University of Michigan Health System, Department of Radiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Adler, Jeremy [University of Michigan Health System, Department of Pediatrics and Communicable Diseases, Division of Pediatric Gastroenterology, Ann Arbor, MI (United States); Zimmermann, Ellen M. [University of Michigan Health System, Department of Internal Medicine, Division of Gastroenterology, Ann Arbor, MI (United States)

    2010-01-15

    CT enterography is an important tool in the noninvasive diagnosis and follow-up of pediatric Crohn disease. This imaging modality is particularly useful for assessing extent of disease (including both intestinal and extraintestinal manifestations), response to medical therapy, and disease-related complications. The purpose of this article is to provide a contemporary review of CT enterography technique as well as the spectrum of intestinal and extraintestinal findings in pediatric Crohn disease. (orig.)

  15. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Julka, Pramod Kumar [All India Institute of Medical Sciences, Department of Radiation Oncology, New Delhi (India); Thulkar, Sanjay [All India Institute of Medical Sciences, Department of Radiodiagnosis, New Delhi (India)

    2012-07-15

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 {+-} 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score {<=}2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images ({kappa} = 0.426), while almost perfect agreement was seen for CT ({kappa} = 0.834) and SPECT-CT ({kappa} = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  16. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  17. Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT; Darstellung subtiler Schlaefenbeinstrukturen. In-vivo-Vergleich digitale Volumentomographie vs. Multidetektor-CT

    Energy Technology Data Exchange (ETDEWEB)

    Pein, M.K.; Plontke, S.K. [Universitaetsklinikum Halle (Saale), Universitaetsklinik und Poliklinik fuer HNO-Heilkunde, Kopf- und Halschirurgie, Halle (Saale) (Germany); Brandt, S.; Koesling, S. [Universitaetsklinikum Halle (Saale), Universitaetsklinik und Poliklinik fuer Diagnostische Radiologie, Halle (Saale) (Germany)

    2014-03-15

    The purpose of this study was to compare the visualization of subtle, non-pathological temporal bone structures on cone beam computed tomography (CBCT) and multi-detector computed tomography (MDCT) in vivo. Temporal bone studies of images from 38 patients archived in the picture archiving and communication system (PACS) were analyzed (slice thickness MDCT 0.6 mm and CBCT 0.125 mm) of which 23 were imaged by MDCT and 15 by CBCT using optimized standard protocols. Inclusion criteria were normal radiological findings, absence of previous surgery and anatomical variants. Images were evaluated blind by three trained observers. Using a five-point scale the visualization of ten subtle structures of the temporal bone was analyzed. Subtle middle ear structures showed a tendency to be more easily distinguishable by CBCT with significantly better visualization of the tendon of the stapedius muscle and the crura of the stapes on CBCT (p = 0.003 and p = 0.033, respectively). In contrast, inner ear components, such as the osseus spiral lamina and the modiolus tended to be better detectable on MDCT, showing significant differences for the osseous spiral lamina (p = 0.001). The interrater reliability was 0.73 (Cohen's kappa coefficient) and intraobserver reliability was 0.89. The use of CBCT and MDCT allows equivalent and excellent imaging results if optimized protocols are chosen. With both imaging techniques subtle temporal bone structures could be visualized with a similar degree of definition. In vivo differences do not seem to be as large as suggested in several previous studies. (orig.) [German] Vergleich der Identifizierbarkeit subtiler Schlaefenbeinstrukturen in der digitalen Volumentomographie (DVT) und Multidetektor-CT (MDCT) in vivo. Analysiert wurden 38 im PACS (Picture Archiving and Communication System) duennschichtig gespeicherte Schlaefenbeinuntersuchungen (23 MDCTs, Schichtdicke 0,6 mm sowie 15 DVTs, Schichtdicke 0,125 mm). Einschlusskriterium war eine

  18. CT analysis of missile head injury

    Energy Technology Data Exchange (ETDEWEB)

    Besenski, N. [Dept. of Radiology, Zagreb Univ. Hospital Rebro (Croatia); Jadro-Santel, D. [Dept. of Neuropathology, Zagreb Univ. Hospital Rebro (Croatia); Jelavic-Koic, F. [Dept. of Radiology, General Hospital Sveti Duh, Zagreb (Croatia); Pavic, D. [Dept. of Neuropathology, Zagreb Univ. Hospital Rebro (Croatia); Mikulic, D. [Zagreb School of Medicine (Croatia); Glavina, K. [Dept. of Radiology, Clinical Hospital, Osijek (Croatia); Maskovic, J. [Dept. of Radiology, Clinical Hospital, Split (Croatia)

    1995-04-01

    Between August 1991 and December 1992, CT was performed in 154 patients who had suffered missile head injury during the war in the Republic of Croatia. In 54% CT was performed 1-24 h after injury, and in 27% follow-up CT was also obtained. The wounds were penetrating, tangential or perforating (45%, 34% and 21%, respectively). Haemorrhage was the most frequent lesion in the brain (84%). Follow-up CT evolution of haemorrhage, oedema, cerebritis, abscess, secondary vascular lesions, necrosis, encephalomalacia and hydrocephalus. The most dynamic changes occurred 7-14 days after injury. In 14% of cases, deep cerebral lesions were found in the corpus callosum, septum pellucidum periventricular region and pons, although bone and shell fragments were in a different part of the brain parenchyma. Such lesions were found in penetrating injuries only. CT proved very useful for assessing the extent and type of lesions. Although different mechanisms of brain damage in missile head injury are known, here they are, to the best of our knowledge, shown for the first time by CT. (orig.)

  19. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a good'' surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  20. CT imaging of enhanced oil recovery experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gall, B.L.

    1992-12-01

    X-ray computerized tomography (Cr) has been used to study fluid distributions during chemical enhanced oil recovery experiments. Four CT-monitored corefloods were conducted, and oil saturation distributions were calculated at various stages of the experiments. Results suggested that this technique could add significant information toward interpretation and evaluation of surfactant/polymer EOR recovery methods. CT-monitored tracer tests provided information about flow properties in the core samples. Nonuniform fluid advance could be observed, even in core that appeared uniform by visual inspection. Porosity distribution maps based on CT density calculations also showed the presence of different porosity layers that affected fluid movement through the cores. Several types of CT-monitored corefloods were conducted. Comparisons were made for CT-monitored corefloods using chemical systems that were highly successful in reducing residual oil saturations in laboratory experiments and less successful systems. Changes were made in surfactant formulation and in concentration of the mobility control polymer. Use of a poor mobility control agent failed to move oil that was not initially displaced by the injected surfactant solution; even when a ``good`` surfactant system was used. Use of a less favorable surfactant system with adequate mobility control could produce as much oil as the use of a good surfactant system with inadequate mobility control. The role of mobility control, therefore, becomes a critical parameter for successful application of chemical EOR. Continuation of efforts to use CT imaging in connection with chemical EOR evaluations is recommended.

  1. Helical CT in acute lower gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Olivier; Leroy, Christophe; Sergent, Geraldine [Department of Radiology, Hopital Huriez, 1 rue Polonovski, 59037 Lille (France); Bulois, Philippe; Saint-Drenant, Sophie; Paris, Jean-Claude [Department of Gastroenterology, Hopital Huriez, 1 rue Polonovski, 59037 Lille (France)

    2003-01-01

    The purpose of this study was to assess the usefulness of helical CT in depicting the location of acute lower gastrointestinal bleeding. A three-phase helical CT of the abdomen was performed in 24 patients referred for acute lower gastrointestinal bleeding. The diagnosis of the bleeding site was established by CT when there was at least one of the following criteria: spontaneous hyperdensity of the peribowel fat; contrast enhancement of the bowel wall; vascular extravasation of the contrast medium; thickening of the bowel wall; polyp or tumor; or vascular dilation. Diverticula alone were not enough to locate the bleeding site. The results of CT were compared with the diagnosis obtained by colonoscopy, enteroscopy, or surgery. A definite diagnosis was made in 19 patients. The bleeding site was located in the small bowel in 5 patients and the colon in 14 patients. The CT correctly located 4 small bowel hemorrhages and 11 colonic hemorrhages. Diagnosis of the primary lesion responsible for the bleeding was made in 10 patients. Our results suggest that helical CT could be a good diagnostic tool in acute lower gastrointestinal bleeding to help the physician to diagnose the bleeding site. (orig.)

  2. Usefulness and limit of CT diagnosis on appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Kuchiki, Megumi; Takanashi, Toshiyasu [Sakata Municipal Hospital, Yamagata (Japan); Yamaguchi, Koichi

    1997-08-01

    CT was performed in 104 patients with abdominal pain suspected appendicitis. CT showed positive finding (abnormal appendix, appendicolith, pericecal inflammatory change, fluid collection, LN swelling, abscess) and complication of appendicitis clearly. CT diagnosis showed high accuracy than clinical diagnosis. CT proved its usefulness especially only CT imaging showed the correct diagnosis. On the other hand, diverticulitis and terminal ileitis common diagnostic disease of appendicitis showed similar clinical appearance and CT image, caused to be difficult to diagnose correctly. In the cases showing similar image to appendicitis or atypical image, CT also proved its limit of the diagnosis on appendicitis. (author)

  3. Rheumatoid arthritis bone erosion volumes on CT and MRI: reliability and correlations with erosion scores on CT, MRI and radiography

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Ejbjerg, Bo J; Hasselquist, Maria;

    2007-01-01

    controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). RESULTS: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean...

  4. How to choose PET-CT or CT in the diagnosis and staging of lung cancer. Practical experience in China

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, T.; Tao, X.; Liu, H.; Liu, S. [Dept. of Radiology, ChangZheng Hospital, Second Military Medical Univ., SH (China); Zheng, X. [Dept. of Nutrition, ChangHai Hospital, Second Military Medical Univ., SH (China)

    2010-07-01

    How to use CT and PET-CT rationally to raise diagnosis, staging and prognostic assessment of lung cancer to a higher level at the best cost-effect ratio is a subject that Chinese clinicians and radiologists should face conscientiously. We review the rational application of CT and PET-CT in four aspects of lung cancer, including screening and detection, morphologic evaluation, haemodynamic or metabolic feature evaluation, and follow-up, staging and prognostic evaluation. As PET-CT is only available in class III-A hospitals today, CT is the most popular equipment in China. PET-CT is more valuable only in cases where CT presentation of lung cancer is atypical or difficult to determine, or in cases where the diagnosis of lung cancer has been initially confirmed, for which clinical staging and decision concerning on therapeutic regimens are needed. We also recommend the current strategies of CT and PET-CT managing of SPN in China. (orig.)

  5. CT assessment of anastomotic bowel leak

    Energy Technology Data Exchange (ETDEWEB)

    Power, N. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Atri, M. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)]. E-mail: mostafa.atri@sw.ca; Ryan, S. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Haddad, R. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Smith, A. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)

    2007-01-15

    Aim: To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Subjects and methods: Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10 {+-} 5.9 SD) for the anastomotic group and 3-40 days (mean 14 {+-} 11 SD) for the control group (p = 0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. Results: The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4 {+-} 6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only