For diagnosis of loosening or infection after implantation of a single-side or double-side total hipendoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte scintigraphy can detect ...
BackgroundThere have been reports both supporting and refuting an inverse relationship between hip fracture and hip osteoarthritis (OA). We explore this relationship using a case-control...Full Text Available
Examination of a painful hip is fairly concise and reliable at detecting the presence of a hip joint problem. Hip joint disorders often go undetected, leading to the development of secondary disorders....Full Text Available
BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available
The European demonstration project HipHip (house integrated photovoltaic high-tech in public) led the French photovoltaic market to reach a level comparable to those of the other European countries in terms of relevance of implemented solutions and costs. This document presents the best realizations and the experience gained through the HipHip project. Its aim is to convince the designers and managers of building projects of the advantages of photovoltaic installations integrated to the structure and connected to the power distribution grid: 1 - presentation of the technology; 2 - status of the HipHip demonstration project (goals, results: main innovations and impact on the French market); 3 - different possibilities of integration to the building structure; 4 - examples of projects realized in France in the framework of the Hip ...
BackgroundNorway, and particularly Oslo, has the highest reported incidence of hip fractures in the world. It is increasingly common to care for older hip fracture patients in orthogeriatric...Full Text Available
BackgroundModern metal-on-metal hip resurfacing implants are being increasingly used for young and active patients, although the long-term outcome and failure mechanisms of these...Full Text Available
Earlier we have shown that exogenous expression of HIPPI, a molecular partner of Huntingtin interacting protein HIP-1, induces apoptosis and increases expression of caspases-1, -8 and -10 in HeLa and...Full Text Available
Hip fractures are associated with a high rate of mortality and profound temporary and sometimes permanent impairment of quality of life. Current guidelines indicate that surgeons should perform surgery...Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
OBJECTIVE:To evaluate the profile of osteoporosis treatment among patients hospitalized due to hip fractures at a tertiary-level university hospital. To compare the impact of hospitalization...Full Text Available
BackgroundHip fracture patients often have an impaired nutritional status at the time of fracture, which can result in a higher complication rate, prolonged rehabilitation time and...Full Text Available
BackgroundThe purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty.MethodsWe...Full Text Available
BackgroundHip resurfacing arthroplasty (HRA) is considered a bone-preserving procedure and may eliminate proximal femoral stress shielding and osteolysis. However, in addition to...Full Text Available
BackgroundThe effects of intervention programs on health-related quality of life (HRQOL) of patients with hip fracture have not been well studied. We hypothesized that older patients...Full Text Available
The aim of this study was the evaluation of contralateral hip fractures after a previous hip fracture. For this retrospective analysis patients were selected from the database of the LUMC, a teaching hospital in the south-west of the Netherlands. We analyzed all patients with a second fracture of a hip between 1992 and 2007. The exclusion criteria were high impact trauma and patients with diseases or medication known to have a negative effect on bone metabolism. A total of 1,604 hip fractures were identified. The possible predictive factors for the second fracture and descriptive statistics related to surgery (Hb and HT before and after the operation, total amount of intra- and postoperative blood loss, type of osteosynthesis, complications, time of death after the last fracture, time betw...
Forty-one patients with uncomplicated gall stone disease were laparoscopied with the object of cholecystectomy. The procedure was accomplished in 36 patients, but the operation had to be transformed to a conventional open operation in five: Fibrosis made dissection of the gall bladder hazardous in four and bleeding during the procedure made immediate laparotomy necessary in one patient, whose postoperative course was uneventful. The median operating time was 100 minutes, range was 60-250 minutes. The only operative complication was bleeding from a trocar puncture hole on the first postoperative day which stopped spontaneously in one patient. Eighteen were sent home on the first postoperative day and 12 patients on the second day. Peroperative cholangiography was performed employing the Olsen-Reddick cholangiography forceps. We have designed a special catheter, which greatly facilitates the procedure. The procedure was accomplished in 27 of 32 planned cases. Two patients had common bile ...
Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone ...
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
Background There is increasing recognition that lower nurse staffing levels are associated with higher morbidity and mortality among medical and surgical patients. The degree to which this applies to elderly patients with hip fractures is unclear. Questions/purposes We conducted a pilot study using administrative data as an initial step in investigating the relationship between nurse staffing levels and in-hospital mortality among elderly patients with hip fractures. Patients and Methods We retrospectively reviewed administrative data for 13,343 patients 65?years or older with a primary diagnosis of hip fracture admitted to 39 Michigan hospitals between 2003 and 2006. We used logistic regression to calculate the change in predicted probability of in-hospital death conferred by differences ...
Background:Cemented hip arthroplasty is an established treatment for femoral neck fracture in the mobile elderly. Cement pressurization raises intramedullary pressure and...Full Text Available
The progression of hip dysplasia was investigated in 116 military working dogs. Serial pelvic radiographs were graded for degree of dysplasia and degenerative joint disease (DJD). Norberg angles, angles of inclination, and joint space widths were measured. There was a significant correlation between the Norberg angle and the degree of dysplasia (p less than 0.0001). Angles of inclination and joint space width measurements did not demonstrate a correlation to canine hip dysplasia. Dysplastic dogs had a significant estimated risk for development of DJD compared to normal dogs (p less than 0.0001; odds ratio of 70.2). Dogs with normal hip conformation at 24 months of age or older did not develop moderate nor severe DJD. PMID:8875357
Delirium occurs in up to 65% of older hip fracture patients. Developing delirium in hospital has been associated with a variety of adverse outcomes. Trials have shown that multi-component preventive...Full Text Available
Objective. The aim of this study was to assess the capability of high-resolution images obtained with a commercially available pelvic phased-array surface coil to demonstrate normal hip anatomy. Design. We retrospectively analyzed the oblique coronal magnetic resonance (MR) images of hips of 36 consecutive patients acquired on a 1.5-T clinical imager using a pelvic phased-array coil as a receiver, a 16-20 cm field of view, and 5 mm slice thickness. Patients. Thirty-six patients were studied, age 15-81 years. There were 20 males and 16 females. Results and conclusions. The articular cartilage, cortex, superior labrum, and iliofemoral ligament were well visualized on proton density weighted fat saturation (PDF) images. The femoral and obturator vessels, obturator nerve, and various muscles were easily seen on T1-weighted images. High-resolution imaging of the hip is achievable in a reasonable amount of time using newer ...
Abstract Background:- Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. Methods:- We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. Results:- There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index ...
The treatment of acetabular bone defects presents a great challenge in revision total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiological outcome of revision THA using jumbo cups for acetabular reconstruction after applying the bone-grafting technique. We studied 17?patients with acetabular defects ranging from Type 2A to Type 3A according to Paprosky`s classification. According to the AAOS-score twelve patients were classified as Type II and five patients as Type III. Uncemented press-fit cups with an outer diameter larger than 64?mm were used in all cases. Fifteen patients received morselized bone allografts. In eight patients an additional screw fixation was necessary. The mean follow-up period was 82?months (range 33?149). The mean Harris Hip...
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for radiation oncology patients ...
Densification of Y_2O_3 by HIP was investigated in the range 1250"0C-1550"0C at a pressure of 150 MPa. Runs were made in metallic capsules with 200 g of powder. The powder under investigation is 99.9% purity, supplied by RHONE-POULENC. The study reveals the importance of residual gases in the HIP technique of powder densification. The density of the final product is in the range 93% to 100% of theoretical density depending on pretreatment (or outgassing) of the powder. Residual gases have been identified. Final products have been characterized by microscopy (grain size, porosity, microhardness). Porosity and grain size depend on pretreatment conditions. In particular a 1200"0C pretreatment results in zero porosity and significant decrease of grain size. 4 tables, 11 figs, 16 refs.
The progression of hip dysplasia was investigated in 116 military working dogs. Medical records were reviewed for any clinical history of hind-limb lameness. Pelvic radiographs were studied for evidence and degree of hip dysplasia, degenerative joint disease, or both. The number of months each dog worked was determined. Each dog's age at termination from service and cause of death (or euthanasia) were recorded. The mean months of work for normal and dysplastic dogs were evaluated using the Student's t-test. No significant difference was found in the total number of months worked between normal and dysplastic dogs (p greater than 0.05). PMID:8875358
Background and purpose It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following...Full Text Available
BackgroundThe analgesic effect of perioperative low doses intravenous lidocaine has been demonstrated after abdominal surgery. This study aimed to evaluate whether...Full Text Available
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral ...
Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the ...
AimsTo describe the pharmacokinetic–pharmacodynamic (PK–PD) characteristics of the direct thrombin inhibitor dabigatran in hip replacement patients by assessing coagulation...Full Text Available
Non-cemented femoral fixation in hip arthroplasty has become the standard of practice in the USA. However, recent literature has brought attention to an increasing incidence of periprosthetic femur...Full Text Available
BackgroundHip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral...Full Text Available
Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...
An 82-year-old female, with left femoral neck fracture was scheduled for left hip hemiarthroplasty, under spinal anaesthesia. She had been suffering from diabetes, hypertension, lung cancer and was...Full Text Available
INTRODUCTIONCutiplast (absorbent perforated dressing with adhesive border; Smith & Nephew) is commonly used following orthopaedic operation, but complications of its use...Full Text Available
The viability of osteocytes can be demonstrated in sawn decalcified sections of bone by their lactate dehydrogenase activity. In the cancellous bone of the femoral head, the proportion of lacunae containing viable osteocytes decreased from 88 +/- 7% (mean +/- SD) at 10-29 years to 58 +/- 12% (P Ultimate compressive strength did not correlate with osteocyte viability. In the femoral head there is gradual, age-related reduction in osteocyte viability that can be more pronounced in hip fracture. Osteocyte death may affect bone quality by impairing repair of fatigue damage. PMID:8275364
The microstructure and mechanical properties of a specimen HIPped at 1100 C under 60 ksi were examined. The examinations indicated that the proper HIPping temperature for this material should be higher than 1100 C. New recipe of monolithic material was developed and presented better extrusion homogeneity and less binder removal defects. However, cracking still occurred in specimens although very slow heating rate of 0.25 C/min for binder burnout was used.
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs ...
The Outstanding Achievement Award in Water Pollution Control' is intended to recognize the water pollution control program that best demonstrates achieving significant, lasting, and measurable excellence in water-quality improvement in preventing water-quality degradation in a region, basin, or water body. This article is about the 1991 Award. This year, WPCF honored Los Angeles Hyperion Treatment Plant with a citation of outstanding achievement. To qualify for this honor, Hyperion has remarkably improved the quality of wastewater discharged to Santa Monica Bay since 1985. Capital programs developed by Los Angeles to achieve this rapid improvement, coined the Hyperion Improvement Program (HIP), reflect the city's commitment to protect the valuable resource of Santa Monica Bay. The HIP was conceived in 1986 to cease sludge ocean disposal by the end of 1987 and expedite effluent quality improvement before 1991, when the full ...
The methodology of achieving a high power density (HPD, or brake mean effective pressure) direct-injection Diesel engine has been studied, which is directed to using high fuel/air ratio, high-speed and ceramic engine components. Among the main thrust to achieve these engine changes for an advanced Diesel engine is the design of a high injection pressure (HIP) fuel system. During the course of the present study, two Cummins 903 engines mated with a Rutger-built HIP were employed to investigate the engine response to HIP and in-cylinder processes by using the Rutgers high-speed infrared (IR) spectral digital imaging system. Five separate technical publications were prepared to report results obtained from the study. The main findings include: The HIP system permits engine operation at an air/fuel ratio of as rich as 18 to 1 with smoke emission not worse than with the conventional mechanical (low pressure) ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m{sup 2} for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the available database on ...
In the frame of the European Technology R and D program for ITER, and in the area of High Heat Flux plasma facing Components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, Hot Isostatic Pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most promising one, particularly when the HIPping manufacturing technology is used. Within this program, ENEA manufactured tungsten monoblock mock-ups by using the HIPping technology. The mock-ups were tested with respect to thermal fatigue and, upon screening tests, the best performance obtained was 15 MW/m"2 for 200 cycles. One of these mock-ups was enclosed in the 'Paride' neutron irradiation campaign. This campaign has the scope of enlarging the available database on the performance ...
Forty-five patients with recent cervical hip fractures were included in a prospective, clinical, radiographic and sequential scintimetric study. Striking changes in radionuclide uptake over the entire hip region on the fracture side were found during the first 5 postoperative months. Fractures that healed without complications showed the highest relative femoral head uptake at 1 week and a peak value at 6 weeks, followed by a gradual decline at the subsequent examinations. Fractures with complications (redisplacement, nonunion, or late segmental collapse) showed a lower initial uptake and a more gradual increase and only a slight tendency towards increased uptake after 3 months. The accuracy in predicting nonunion with scintimetric examination alone is high both at 1 and at 6 weeks, and the accuracy is almost equally high with combined scintimetric, radiographic, and clinical assessment 3-5 months postoperatively.
Background The lateral femoral cutaneous nerve (LFCN) can be at risk during, for example, the insertion of pins in the anterior superior iliac spine (ASIS) during external fixation of the pelvis, total hip arthroplasty through a direct anterior approach, open surgery for impingement in the hip through an anterior approach, and periacetabular osteotomy. During surgery, the surgeon usually assumes the location of the LFCN by using the ASIS as a landmark. Questions/purposes We investigated (1) whether there is any relationship between the LFCN and the ASIS and (2) the anatomy of the LFCN at the lateral border of the psoas major. Methods Using 25 formalin-fixed cadavers, we determined the location of the LFCN emergence point as above, same level with, or below the iliac crest (IC). We measured...
In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)
Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern ...
A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.
...prosthesis) Anatomical loss near hip (preventing use of prosthesis) Anatomical loss or loss of use below elbow M Codes M-1 a, b, or c, 38 CFR 3.350 (c)(1)(i) L Codes L-1 d, e, f, or g, 38 CFR 3.350(b)...
In the frame of the European Technology R and D programme for International thermonuclear experimental reactor (ITER) and in the area of high heat flux plasma facing components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, hot isostatic pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most robust one, particularly when the HIPping manufacturing technology is used. Within this programme, ENEA developed an alternative technique for manufacturing plasma-facing components with a monoblock geometry of the ITER machine. The basic idea of this technique, named hot radial pressing (HRP), is to perform a radial diffusion bonding between the cooling tube and the armour tile by pressurising the internal tube only and by keeping the process parameters ...
The Belgian Malinois dog was introduced into the Department of Defense Military Working Dog Program in 1984. All dogs are purchased in Europe and have adapted well to the rigorous training requirements of the program. Most veterinary problems seen in this breed are related to kennel confinement and include traumatic dental disease, tail lesions, a variety of dermatologic conditions, and an inability to gain weight. Epilepsy is a breed problem and has been seen in this population, as has gastric dilatation/volvulus. Both elbow and hip dysplasia exist in the Malinois breed. PMID:1900116
Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische ...
This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm2, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm2, 0.3 and involving L-5 increased to 0.077 g/cm2, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to 0.006 g/cm2, 0.1 and in 2 cm, 0.021 g/cm2, ...
Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H_2"1"5O dynamic study method and blood volume was measured by means ...
Test Blanket Modules (TBM) will be tested in ITER to verify the capability of tritium breeding and recovery and the extraction of thermal energy suitable for the production of electricity. A Helium Cooled Solid Breeder (HCSB) TBM has been developed in Korea to accomplish these goals. Reduced Activation Ferritic/Martensitic (RAFM) steel has been chosen as the primary candidate structural material for Korean TBM. Due to the complexity of the First wall (FW) and Side wall (SW), it is necessary to develop various joining technologies, such as Hot Isostatic Pressing (HIP), Electron Beam Welding (EBW) and Tungsten Inert Gas (TIG) welding, for the successful fabrication of TBM. In this study, the mechanical properties of TIG welded RAFM steel were investigated. Various mechanical tests of TIG-welded RAFM steel were performed to obtain the optimized TIG welding process for RAFM steel
Femoral head replacement was performed for femoral neck fracture or femoral head necrosis on 36 hips of 34 patients on whom Tc-99m MDP scintigraphy was done for analysis of radioisotope uptake around the prosthesis. In the cases with satisfactory clinical course after replacement surgery the uptake was high in the area between the prosthesis and the trochanter, in the area of the stem tip of the prosthesis and in the acetabular area. The high uptake decreased gradually and reached a normal level by 8 months after surgery. The cases with no decrease of high uptake by 8 months after surgery were considered to have had an eventful postoperative course associated with some complication such as infection, fracture, loosening etc. Tc-99m MDP scintigraphy was useful for early detection of complications and to evaluate progress of the operated patients. (author)
Summary The aim of this cross-sectional study was to find possible relationships between insulin-like growth factor-1 (IGF-1), adipocytokines (leptin and adiponectin) and twitch contraction (TC) characteristics of the knee extensor (KE) muscles in healthy physically active postmenopausal women (n = 28, 64-78 years old). We hypothesized that IGF-1 is related at least to isometric TC peak torque (Pt) as the highest value of isometric torque production and maximal voluntary contraction (MVC) torque, and there will not be any relationships between TC characteristics and leptin and adiponectin. During the measurement of MVC torque and twitch contractile properties of KE muscles, the subjects sat in a custom-made dynamometric chair with the knee and hip angles equal to 90degree and 100degree, re...
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
Running torque of bearings, temperature rise of the lubricating oil and power loss of the testing system were compared with hybrid ceramic bearings set HIP-Si{sub 3}N{sub 4} balls and AISI-M 50 steel ball bearings under the 2 million dN value ({phi}20 x 100,000 rpm). Over 1.4 dN value, hybrid ceramic bearings showed superior performance than M 50 steel ball bearings. If the proper oil filling condition is chosen, hybrid ceramic bearings reduce bearing power loss to about 55% of AISI-M 50 steel ball bearings at 2 million dN value. (author)
In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.
In a retrospective single-centre study 170 consecutive patients were included who received a Kotz modular prosthesis after resection of bone tumours of the proximal femur to evaluate the management of prosthetic infection. Infection occurred in 12 of 166 patients available for follow-up (six males; six females; mean age, 47?years; range, ten to 75?years) after a mean of 39?months (range, one to 166?months; infection rate, 7.2%). Mean follow-up was 54?months (range, four to 200?months). One patient died of septic shock. Two patients were treated by wound revision only. Treatment of infection in the remaining patients was one-stage revision in eight and hip disarticulation in one. Infection control by one-stage revision was achieved in five of eight patients; re-infection occurred in three p...
International Thermonuclear Experimental Reactor (ITER) project is the international collaboration one for the commercialization of nuclear fusion energy through the technical and engineering verification. In ITER project, we plan to procure the blanket systems which has the risk of technology and cost when it is newly developed. We are developing the manufacturing process and joining technology for the ITER blanket to complete the procurement with qualified blanket system. To evaluate the soundness of manufacturing process, specimen and mock-up tests are being prepared. Finally, we can obtain the key technology of nuclear fusion reactor especially on the blanket design, joining and manufacturing technology through the present project and these technologies will help the construction of Korea fusion DEMO reactor and the development of commercial nuclear fusion reactor in Korea. In 1st year, through the fabrication of the Cu/SS and Be/Cu joint specimen, fabrication procedure such as ...
Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...
Background: Apheresis is a procedure to selectively obtain blood components. For the collection process citrate is routinely used. It inhibits coagulation by binding to ionized calcium and leads to metabolic alkalosis. Objective: Whether regular apheresis affects bone and mineral metabolism is unknown. The intention of this study was to investigate 1) the acute effects of apheresis on acid-base balance, bone and mineral metabolism and 2) to compare bone mineral density (BMD) at the lumbar spine and hip of donors to matched control subjects. Design: In this open, observational, single-center, cross-sectional study we enrolled 102 regular plasma and thrombocyte donors to pursue objective 1) and compared those to 102 matched controls (CTR) for objective 2). Results: Platelet donation led to s...
Pyogenic sacroiliitis is a rare entity in children. Diagnosis is often delayed because of its variable clinical presentation, low suspicion by the examining physician, and rare findings on radiographs. Delayed diagnosis, however, results in complications such as iliopsoas abscess. We report the case of a 12-year-old girl hospitalized with a 21-day history of fever, pain in the left iliac fossa, and flexion contracture of the hip. On examination, she had fever (38.9 ^oC), psoitis, localized tenderness at the left sacroiliac joint, and pain elicited by lateral compression of the pelvis. The abdominal examination was normal. The erythrocyte sedimentation rate was 130mm in the first hour, C-reactive protein was 186mg/l, and the white blood cell count was 18,400/mm^3, with 79% neutrophils. Urin...
The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten?years (ten to 18) and a mean age of 42?years (18?50). The overall revision rate at 14?years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11?mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclus...
The design of the ITER primary first wall incorporates a multi-layered structure consisting of a layer of beryllium bonded to a layer of copper alloy with embedded stainless steel tubes which in turn is bonded to a stainless steel structure. In this configuration, the stainless steel provides structural support, the copper alloy improved resistance to high heat loads, and the beryllium layer a low Z metal interface with plasma. Fabrication, testing and control of this multi-layered structure, and indeed the entire blanket shield module, calls for advanced methods. Several associations in the four home teams and their industrial partners have been involved in various fabrication and joining tasks now grouped under L4 blanket project. In this paper, an overview of the work done so far for joining stainless steel to stainless steel, stainless steel to copper alloy, copper alloy to copper alloy, and copper alloy to beryllium is presented. Specialised papers dealing with most of the topics ...
One of the main causes of hip prostheses failure is the premature wear of its components. Wear of metal-on-metal joints is a concern due to the toxicity and biological reaction of wear debris and metallic corrosion. The main aim of the present study was to investigate the tribological and corrosion behavior of surface engineering CoCrMo alloy. Different surface conditions were obtained on surgical grade wrought CoCrMo alloy: plasma nitrided (520^oC by 7h at gas mixture of 10% N2+90% H2), PVD coated (monolayer CrN and multilayer (TiN/CrN)x3) and modified using duplex surface engineering technology (a combination of the two previous approaches: plasma nitriding followed by plasma assisted PVD). Surfaces were characterized using scanning electron microscopy, nanoindentation, AFM and scratch t...
In 1998, in the frame of the ITER EDA phase, an European R and D Programme for the Blanket Design was implemented for developing and selecting the materials and the relevant fabrication procedures for manufacturing the shielding modules of the ITER Primary Wall. The fabrication of several Beryllium armored small scale mock-ups, reproducing representative portions of a Primary Wall panels, was also launched (Fusion Technol. (1998) 195). Further experimental activities were also programmed for investigating the thermal-mechanical behavior of these mock-ups at high heat flux and under thermal fatigue tests. In 2001, the ITER European Home Team decided to assign to ENEA a contract for the thermal fatigue testing of six mock-ups aiming at verifying the reliability of the Beryllium/Dispersion Strengthened Copper alloy/Stainless Steel and Beryllium/Precipitation hardened Copper alloy/Stainless Steel joints manufactured by solid Hot Isostatic Pressing (HIP) procedure ...
The present design of Blanket Shield and Primary Wall for ITER envisages construction of the wall with a water cooled, stainless steel outer layer and a water cooled, copper liner on the inside plasma facing surface. Protection of the inner copper surface with an armour layer is necessary to cope with plasma to wall interaction. There are a number of armour materials under consideration, for this project beryllium was used. The scope of work was to produce a series of mock-ups, each consisting of a different combination of materials, which included Dispersion Strengthened Copper, Copper-Chrome-Zirconium alloy, Beryllium and Stainless Steel. Hot Isostatic Pressing (HIP) was the method used to ensure that a fully diffused bonded joint was achieved giving the necessary strength and thermal conductivity. The first five of the mock ups have been successfully completed and are being tested at the various laboratories in Europe. The remaining mock ups are awaiting the ...
Abuzakuk T, Coward P, Shenava Y, Kumar VS, Skinner JA. The management of wounds following primary lower limb arthroplasty: a prospective, randomised study comparing hydrofibre and central pad dressings. Abstract Wound care following lower limb arthroplasty has not been subject to in-depth clinical research, primarily because such wounds usually heal without complication. However, when prosthetic implants are used, serious wound problems can be disastrous (Whitehouse et al. Infect Control Hosp Epidemiol 2002;23:183-9; Lindwell OM. Clin Orthop Relat Res 1986;211:91-103). We report the results of a prospective, randomised, controlled trial comparing a hydrofibre (Aquacel) and central pad (Mepore) dressing in the management of acute wounds following primary total hip or knee arthroplasty left ...
In 2001, EFDA has assigned to ENEA a contract for the thermomechanical testing of six mock-ups of the ITER primary wall module. These small scale mock-ups, reproducing representative portions of the reference ITER primary wall panels, were fabricated during ITER EDA phase by solid hot isostatic pressing (HIPping) of an AISI 316L stainless steel back structure to a alumina dispersion strengthened (DS)-Cu alloy heat sink armored with beryllium tiles. The experimental program, carried-out at ENEA Brasimone CEF 1-2 thermal hydraulic facility, was focused on the thermal mechanical testing of these mock-ups aiming at verifying which tile geometry and manufacturing procedure assures the required reliability of the beryllium/DS-Cu alloy/SS joints at high incident heat flux (>0.8 MW/m"2) both at steady state and under thermal fatigue tests. The paper presents the progress in the experimental activity of the first test campaign and the main thermomechanical FEM analyses ...
Fourteen patients with cervical hip fractures were treated with internal fixation using titanium screws. The femoral head vitality was evaluated with "9"9Tc"m-MDP scintigraphy and scintimetry within 2 weeks postoperatively and by serial low field magnetic resonance imaging (MR). Two patients with reduced radionuclide uptake (femoral head ratio =# 1.0), MR revealed a focal decrease of the signal intensity in the femoral head or neck at 2, 3 and 7 months after fracture, respectively. The radiographs in one of these patients were normal at 7 months after fracture. The second one showed signs of necrosis at 16 months and the last one developed delayed/non-union. With a non-ferromagnetic osteosynthesis the healing course after femoral neck fracture can be studied with low field MR equipment without disturbing artifacts. The time period between ischaemia and definite abnormalities on MR may embrace several months. (orig.).
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin is taken up by the ...
Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or _9_9 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the ...
A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.
A retrospective study was made of all radionuclide (RN) bone images performed at our institution over a two-year period to evaluate femoral head viability after nonpathologic fracture of the femoral neck. Twelve patients had avascular femoral heads during the perioperative period, of which nine had adequate follow-up. Seven of these nine patients had follow-up bone images. Revascularization occurred in four patients, while three had persistent absence of femoral head uptake. With clinical follow-up ranging from four to 29 months (median: 14 months), only two of these nine patients developed clinical or radiographic evidence of osteonecrosis. RN bone imaging performed in the perioperative period does not reliably predict the development of post-traumatic osteonecrosis of the femoral head and, at present, should not be used to determine prospectively method of treatment of femoral neck fracture.
Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was found out, but ...
The aim of this work was the examination of the coarse grain recrystallisation of the {gamma}-free ODS nickel-based alloy PM 1000 depending on the various parameters due to the processing during heat treatment. After isotropic hot compacting (HIP) of the mechanically alloyed powder, one observes a homogeneous sub-microscopic fine grain structure which can coarsen during high temperature heat treatment, due to sufficiently high driving force from the grain boundary energy via abnormal grain growth to 600 times its size. The setting of the elongated high temperature resistant recrystallisation structure is, however, not connected with this. The dependence of the sucess of re-crystallisation on the re-forming parameters (re-forming temperature and degree of re-forming) was shown by a socalled re-forming card. In order to achieve re-crystallisation to a coarse and aligned grain structure, apart from a certain absolute minimum degree of re-forming, the re-forming must ...
PVD-coatings based on TiB{sub 2} are expected to show high wear resistance and low tendency of adhesion on metal forming tools. Coating adhesion and morphology can be modified over a wide range by varying the content of nitrogen (N{sub 2}) and the deposition parameters power and bias voltage. All coatings were deposited using commercial unbalanced magnetron equipment, the deposition was homogeneous in a volume of 400 x 400 x 400 mm{sup 3}. Hipped and hot pressed TiB{sub 2}-targets were used, nitrogen (N{sub 2}) was added as gas, Ti and Al by a solid Ti-Al-target. The tribological behaviour was tested by a pin-on-disc wear test. The coatings investigated were TiB{sub 2}, TiAlB(N), TiAl(N) and TiB{sub 2}/TiAl(N). As counterpart in the pin-on-disc wear test, 6 mm diameter spheres of steel (100Cr6), aluminium, brass and bronze were used. The experiments showed a non-uniform wear behaviour. For the combinations TiAlB(N) and TiB{sub 2} versus aluminium, a low wear volume ...
On 21 October 1994, three brothers entered a waste repository at Tammiku, Estonia, without authorization and removed a metal container enclosing a caesium-137 source. During the removal the source was dislodged and fell to the ground. One of the men picked up the source, placed it in his pocket and took it to his home in the nearby village of Kiisa. Very soon after entry into the repository he began to feel ill, and few hours later he began to vomit. The man was subsequently admitted to hospital with severe injuries to his leg and hip and died on 2 November 1994. The injury and subsequent death were not attributed to radiation exposure, and the source remained in the man's house with his wife and stepson and the boy's great-grandmother. The boy was hospitalized on 17 November with severe burns on his hands, and these were identified by a doctor as radiation induced. The authorities were alerted, and the Estonian Rescue Board recovered the source from the house. The ...
Out of the R and D of mesoscopic metal group composite materials, the paper described the fiscal 1997 results. In the in-situ method as a composite material making method, elucidated to some degree were chemical composition of Fe-C-Cr-V-Nb-Mo-W-Ni base multi-dimensional alloys, and wear resistance and oxidation resistance of MC type carbide dispersion multi-phase texture crystallizing as primary crystal and eutectic. In the composite material making with ceramic fiber and alloy by the pressure infiltration method, the paper clarified the texture formation mechanism in solidification/heat treatment by a combination of Al alloys and alumina long fiber, and the relation between fiber configuration and wear resistance. By MA and MG methods as the powder metallurgy composite material making method, a composed body of {alpha}-stainless steel of Fe-12%Cr composition and M23C6 of 40-90vol% are designed for alloy composition, and powder of amorphous or hyperfine texture was fabricated. By hot ...
The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts showed absent femoral head activity on their ...
Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 ...
This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). In an effort to address the problems of long term storage and nuclear waste minimization, zircon has been proposed as a host medium for plutonium and other actinides recovered from dismantled nuclear weapons. The objective of this work is to investigate the feasibility of large scale fabrication of Pu-bearing zircon. Since PuO_2 is thermodynamically less stable than ZrO_2, it is expected that the process parameters determined for synthesizing ZrSiO_4 (zircon) would be applicable to those for PuSiO_4 (Pu-zircon). Furthermore, since the foremost concern in plutonium processing is the potential for contamination release, this work emphasizes the development of process parameters, using zircon first, to anticipate potential material problems in the containment system for reaction mixtures during processing. Stoichiometric mixtures of ZrO_2 and ...
Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...
A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average ...
We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD{sub spine}) also measured by DPA, and to the bone-mineral content of the forearms (BMC{sub forearm}) measured by single photon absorptiometry (SPA). TBBD, BMD{sub spine} and BMC{sub forearm} showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD{sub spine} or BMC{sub forearm} with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. ...
Experimental results of compatibility tests on ceramics-metal bonded structures performed under high heat flux conditions in splash test apparatus are reported. Emphasis is placed on results of the channel wall design and its critical operating conditions under MHD environment. The module design of one cold type and three semihot type insulators have been tested. These materials were Al_2O_3, Al_2MgO_4, LaAlO_4, MgO and Sialon ceramics. The methods of cold type ceramics-metal bonding structure were studied on Al_2O_3 and Spinel spray coating technology. The refractory metallizing and ceramics-metal graded structure manufactured by HIP technologies were applied to bonding between the MgO or LaAlO_4 and metallic cooling system. The Sialon non-bonding structure was tested with mechanical supported cooling system by shrinc fitting method. The results indicated that the bonding structures made of the MgO(MG-S) with Copper and Fe-Ni Alloy relaxation layers and MgO(MG-NC) ...
Finite element methods have been applied extensively and with much success in the analysis of orthopaedic implants. Recently a growing interest has developed, in the orthopaedic biomechanics community, in how numerical models can be constructed for the optimal solution of problems in contact mechanics. New developments in this area are of paramount importance in the design of improved implants for orthopaedic surgery. Finite element and other computational techniques are widely applied in the analysis and design of hip and knee implants, with additional joints (ankle, shoulder, wrist) attracting increased attention. The objective of this investigation was to develop a simplified adaptive meshing scheme to facilitate the finite element analysis of a dual-curvature total wrist implant. Using currently available software, the analyst has great flexibility in mesh generation, but must prescribe element sizes and refinement schemes throughout the domain of interest. ...