WorldWideScience
1

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of Flash and Turbo-Flash images, ...

1997-03-01

2

Untersuchungen zur Anwendung von UHPFRC-Tubbingen bei der zweischaligen Tunnelbauweise  

British Library Electronic Table of Contents (United Kingdom)

Faserbewehrter Beton wird heute zunehmend auch bei Tunnelbauwerken (Tunnelinnenschalen, Tubbinge) eingesetzt. Wesentliche Vorteile sind das hohe Tragvermogen, das daraus entstehende Einsparungspotential an herkommlicher stabformiger Bewehrung (Biegebewehrung, Bugelbewehrung in der Randzone), die Aufnahme von Spaltzugbeanspruchungen durch die Fasern, Rissbreitenbegrenzung, erhohte Dauerhaftigkeit, verbesserter Brandwiderstand (insbesondere bei Verwendung von Kunststofffasern), Optimierung der Arbeitsablaufe etc. Neue Entwicklungen in der Betontechnologie haben in den letzten Jahrzehnten den faserbewehrten ultrahochfesten Beton (engl. UHPFRC - Ultra High Performance Fibre Reinforced Concrete) hervorgebracht. Im Rahmen dieser Arbeit wird der Einsatz des ultrahochfesten, stahlfaserbewehrten Be...

2010-01-01

3

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system; Stellenwert der Schnittbildverfahren bei der Abklaerung von Erkrankungen des weiblichen Genitaltrakts  

Energy Technology Data Exchange (ETDEWEB)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein unspezifischer Befund und ...

2001-09-01

4

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted ...

2009-08-15

5

Meltdown and gasification of waste in an oxygen atmosphere; Sauerstoff-Schmelz-Vergasung zur Verwertung von Abfaellen  

Energy Technology Data Exchange (ETDEWEB)

Meltdown and gasification of waste in an oxygen atmosphere ('2sv' process) is an economically efficient alternative to energetic and thermal utilisation of biomass. Organic pollutants are split at temperatures up to 2000 C in a reducing atmosphere. The process uses elements of the oxygen cupola furnace for melting and gasification of many different waste fractions, e.g. polluted waste wood, household refuse and bulk waste, old tyres, light shredder fractions, sewage sludge, etc. [German] Die Sauerstoff-Schmelz-Vergasung ('2sv') stellt eine wirtschaftliche Alternative zur energetischen Nutzung von Biomassen wie auch zur thermischen Abfallverwertung dar. Organische Schadstoffe werden bei diesem neuen Verfahren bei Temperaturen bis zu 2000 C unter reduzierenden Bedingungen aufgespalten. Das Verfahren nutzt Elemente des Sauerstoff-Kupolofens fuer die Schmelzvergasung und ...

2001-06-01

6

Electric intake air heating for small and medium-sized diesel engines; Elektrische Ansaugluft-Vorwaermung bei kleineren und mittleren Dieselmotoren  

Energy Technology Data Exchange (ETDEWEB)

In addition to dependable starting - even at extreme sub-zero temperatures - the starting behaviour of modern commercial vehicle diesel engines is increasingly being evaluated on the basis of HC emissions in the starting and warm-up phases. To improve their performance in this respect, most small and medium-sized diesel engines (with a capacity of 3 to 12 litres) are therefore equipped with intake air heating systems. As an alternative to high-performance, fuel-burning flame start systems, the automotive industry supplier Beru has now developed a new type of self-regulating electric heating element which not only ensures dependable starting with short heating times but also allows drastic reductions in HC emissions. (orig.) [Deutsch] Das Startverhalten moderner Nutzfahrzeug-Dieselmotoren wird, ergaenzend zum Hauptmerkmal des sicheren Starts auch bei extremen Minustemperaturen, zunehmend anhand der HC-Emission in der Start- und Warmlaufphase beurteilt. ...

1997-04-01

7

Einige ?berlegungen zur Unified Strength Theory von?Mao-Hong?Yu  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Das Konzept der ?quivalenten Spannung (Vergleichsspannung) wird seit langem angewendet und hat sich bew?hrt. Ein wesentlicher Grund daf?r liegt darin, dass es u.?a. bei der Formulierung ph?nomenologischer Werkstoffmodelle weiterhilft. Von Nachteil ist, dass es weder mit physikalischen Prinzipien in Verbindung steht, noch Informationen ?ber die Mikrostruktur des Werkstoffs enth?lt. Trotzdem wurden zahlreiche Hypothesen zur Formulierung von ?quivalenten Spannungen in der Vergangenheit aufgestellt und in der Praxis mit unterschiedlichem Erfolg angewendet. Als Basis f?r die Systematisierung der zahlreichen Modelle hat Yu die Unified Strength Theory (UST) vorgeschlagen. Diese eignet sich, u.?a. inkompressibles inelastisches Materialverhalten sowie kompressible Werkstoffe mit unt...

2010-01-01

8

The results of physical modeling of flow in an axial cyclone combustion chamber; Ergebnisse physikalischer Modellierung der Stroemung in einer Axialzyklonbrennkammer  

Energy Technology Data Exchange (ETDEWEB)

The isothermal flow field for the axial cyclone has been experimentally determined. The velocity fields are used for determination particle paths (particle removal and suspended state), and inter alia of heat and mass transfer processes in the axial cyclone combustion chamber. The results are extremely significant as input value approximations for mathematical modelling, since experimentally obtained results are indispensable for complex flows and geometries. (orig.) [Deutsch] Es ist fuer den Axialzyklon experimentell das isotherme Stroemungsfeld ermittelt. Die Geschwindigkeitsfelder dienen zur Ermittlung der Partikelbahnen (Partikelabscheidung, Schwebebedingung), der Waerme- und Stoffuebertragungsprozesse u.a. in der Axialzyklonbrennkammer. Die Ergebnisse sind als Startwertnaeherung bei einer mathematischen Modellierung sehr wichtig, da bei komplexen Stroemungen und Geometrien versuchstechnische Ergebnisse unumgaenglich ...

1994-12-31

9

Local ablading therapy methods in case of liver metastases of colorectal carcinoma; Lokal abladierende Therapieverfahren bei Lebermetastasen kolorektaler Karzinome  

Energy Technology Data Exchange (ETDEWEB)

Clinical studies have proved the effectiveness of local ablading methods in pations with non-resectable liver metastases of a colorectal carcinoma. RF ablation and LITT are a potentially curative therapy option and an alternative to systemic chemotherapy; the latter is carried out primarily for reducing tumour size with the goal of secondary resectability. The number of R0-sesectable metastases can be enhanced by a combined therapy of surgery and local ablading methods, e.g. by preoperative, intraoperative or postoperative ablasion of further non-resectable tumours during surgery. Systemic chemotherapy combined with surgery as an adjuvant method is not recommended unless in cases of non-abladable tumour recidivation. Currently, systemic chemotherapy is used as a neo-adjuvant therapy for tumour size reduction with the goal of secondary resectability or, in case of inoperability, local ablation. (orig.) [German] Abladierende Verfahren. Klinische Studien belegen die Effektivitaet der ...

2003-03-01

10

Technology and cost of waste fermentation with subsequent composting as an alternative to conventional composting; Technik und Kosten einer Restmuellvergaerung mit anschliessender Nachrotte als Alternative zur ausschliesslichen Rotte  

Energy Technology Data Exchange (ETDEWEB)

The author investigates whether waste fermentation is an economically feasible alternative to composting. Decisions on projects and sites should not be made until the basic problems of feasibility and economic efficiency are solved. [German] In Anbetracht der derzeitigen Situation bei der Restmuellbehandlung, in der die mechanisch-biologische Behandlung als Alternative zu einer rein thermischen Behandlung immer mehr an Bedeutung gewinnt, stellt sich immer haeufiger die Frage, ob die Restmuellvergaerung eine Alternative zur ausschliesslichen Restmuellrotte darstellt. Diese Frage muss zunaechst prinzipiell aus Sicht der technischen Machbarkeit und von der Sinnhaftigkeit, hier vor allem von der Kostenseite her, betrachtet werden. Erst daran anschliessend lassen sich projekt- und standortbezogene Betrachtungen anstellen. Hinsichtlich der technischen Machbarkeit laesst sich im wesentlichen auf den grosstechnischen Erfahrungen der letzten 8 Jahre ...

2002-07-01

11

Much news in electric cars; Es tut sich viel bei Elektromobilen  

Energy Technology Data Exchange (ETDEWEB)

There is much interest worldwide in low-emission, low-noise electric cars. Modern vehicles with advanced technology are an interesting alternative to conventional cars. (orig.) [Deutsch] Das Interesse an den emissionsfreien und leisen Elektroautos ist weltweit ungebrochen. Die heute verfuegbaren Fahrzeuge zeigen die betraechtlichen, in den letzten Jahren erzielten Fortschritte, die sie fuer immer mehr Anwender zu einer beliebten Alternative zur Benutzung des konventionellen Autos machen. (orig.)

1998-06-12

12

Device for increasing the decontamination factor in the treatment of radioactive waste water. Vorrichtung zur Erhoehung der Dekontaminationsfaktoren bei der Aufbereitung radioaktiver Abwaesser  

Energy Technology Data Exchange (ETDEWEB)

In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.

1982-06-09

13

Total emissivity and spectral emissivity of high-temperature materials; Gesamtemissionsgrad und spektraler Emissionsgrad von Hochtemperaturmaterialien  

Energy Technology Data Exchange (ETDEWEB)

A new emissivity measurement device with inductive sample heating is described. The disc shaped samples can be measured between 800 C and 2000 C in vacuum or in each available gas atmosphere. Two kinds of surface temperature measurement methods are described, one by measuring in a blackbody hole and one by measuring at the surface without additional measures to correct emissivity. Total normal and spectral emissivity at wavelengths between 0,5 {mu}m and 8,3 {mu}m of various high temperature materials like platinum and Pt-Rh-alloys, siliconcarbide and molybdenum disilicide have been measured. From the investigated materials a few have been selected as reference samples for comparative emissivity measurements fullfilling the requirement of stability on air up to 400 C to 1000 C in order to ensure reproducibility of the results at different measurement conditions in air and in vacuum. (orig.) [Deutsch] Der Aufbau einer neuen Messapparatur fuer Emissionsgradmessungen ...

1998-05-01

14

Measurement of the N{sub 2}O emissions of combustion plants, and studies of air pollution abatement measures. Final report; Messung der N{sub 2}O-Emissionen von Verbrennungsanlagen und Untersuchung von Moeglichkeiten zur Emissionsminderung. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

A high-temperature flow reactor and different technical plants were tested within the framework of this research project. Anthropogenic N{sub 2}O emissions form during secondary flue gas or waste gas purification as secondary emissions during denitrification and pollution abatement measures. N{sub 2}O forms as an intermediate product as NO is reduced to N{sub 2}. Under certain operating conditions N{sub 2}O is not decomposed completely. Different secondary flue gas purification measures, i.e. selective noncatalytic reduction (SNCR), selective catalytic reduction (SCR), and nonselective catalytic reduction (NSCR) were investigated testing several technical plants and the high-temperature flow reactor. (orig./EF) [Deutsch] Das Forschungsprojekt ``Messung der N{sub 2}O-Emissionen von Verbrennungsanlagen und Untersuchung von Moeglichkeiten zur Emissionsminderung`` wurde an einem Hochtemperatur-Stroemungsreaktor und an verschiedenen technischen Anlagen durchgefuehrt. ...

1994-12-01

15

Investigations on process design and fuel substitution in a cokeless, natural-gas-fuelled cupola furnace; Untersuchung zur Prozessgestaltung und Brennstoffsubstitution an einem kokslosen erdgasbefeuerten Kupolofen (KLKO)  

Energy Technology Data Exchange (ETDEWEB)

A process model is presented and used for identifying options for controlling the cupola furnace process and for investigating natural gas substitutes. Fuel substitution will affect temperature curves (i.e. tapping temperatures and melting capacity), outlet temperatures and gas mass flow out of the preheating zone. The contribution presents several process variations to overcome these problems and compares them with the natural gas process. [German] Mit dem Prozessmodell werden zunaechst Moeglichkeiten der Steuerung von Abstichtemperatur und Schmelzleistung, insbesondere unter Beruecksichtigung der Schrottqualitaet (spezifische Oberflaeche a{sub G}), untersucht. Es wird gezeigt, dass das Prozessmodell die Ergebnisse aus der Praxis wiedergibt. Daran anschliessend wird mit dem Prozessmodell die Substitution von Erdgas durch minderwertige Gase untersucht (Brennstoffsubstitution, Ressourcenschonung). Durch die Brennstoffsubstitution veraendern sich die Temperaturverlaeufe und damit auch ...

2001-07-01

16

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood; Aktuelle und zukuenftige Strategien in der interdisziplinaeren Therapie von Medulloblastomen, supratentoriellen PNET und intrakraniellen Keimzelltumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting ...

2001-09-01

17

MRI in combined subacute degeneration of the spinal cord; MRT bei funikulaerer Myelose  

Energy Technology Data Exchange (ETDEWEB)

The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weighted images in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)

1999-06-01

18

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on dose optimization. The program is ...

2002-12-01

19

Modernizing steam turbines for nuclear power plants; Modernisierung von Dampfturbinen fuer Kernkraftwerke  

Energy Technology Data Exchange (ETDEWEB)

Economic and safe operation of nuclear power plants requires reliable steam turbines with high efficiencies. The progress in flow mechanics achieved over the past few years has allowed the use of powerful methods of flow calculation in developments of new blading with greatly enhanced efficiencies. Thanks to the latest manufacturing techniques, the newly developed blading systems can be produced at low cost. Next to progress in flow mechanics, also the broadbased use of advanced finite-element calculations resulted in a more thorough grasp of the many problems associated with structural mechanics assessment of steam turbine components. The theoretical methods have been supplemented by comprehensive efforts in fracture mechanics and experimental materials studies, thus helping to create a reliable knowledge base which will help to avoid the dreaded stress corrosion cracking phenomenon, in components of steam turbines. The measures introduced to improve operational reliability already in ...

1996-01-01

20

Behaviour of heat resistant power plant steels undergoing variable long term loading conditions  

Energy Technology Data Exchange (ETDEWEB)

High temperature components of power plants are in many cases subjected to variable loading conditions such as cyclic creep or strain cycling. Therefore the cyclic behaviour of important heat resistant steels has been investigated under stress control and to a smaller extent under strain control. The behaviour under cyclic creep rupture conditions was determined in long term experiments covering a wide range of loading conditions. This behaviour can be described with the modified life fraction rule and a factor concept of relative life for single stage cycles and additionally with a multistep hypothesis for multi-stage cycles. The description can be adapted to estimate the life consumption under service type random conditions. The strain cycling behaviour was investigated in regard to the conditions of the heated surface of large components. To simulate this type of loading and to generate long term creep fatigue data, a service type strain cycle was developed. Anisothermal and ...

2000-01-01

21

Large lignite steam generators with circulating fluidized bed combustion. Operating experience with a 290 t/h and 400 t/h plant in the RWE power station at Goldenberg; Grosse Braunkohle-Dampferzeuger mit zirkulierender Wirbelschichtfeuerung. Betriebserfahrungen aus der 290 t/h- und der 400 t/h-Anlage im Kraftwerk Goldenberg der RWE Energie AG  

Energy Technology Data Exchange (ETDEWEB)

Early in 1988 RWE decided to overhaul the power station at Goldenberg. This was necessary due to the age of the plant, the obligation to supply heat and process steam and recent amendments of environmental legislation. After analysing demands and needs one developed a plant concept with a 290 t/h and a 400 t/h steam generator. Due to lack of space the decision was made in favour of a circulating atmospheric fluidised bed combustion instead of steam generators with pulverised lignite combustion as these steam generators take up much more space due to the legally required desulphurisation plants for gaseous emissions. Apart from generating steam RWE wishes to gain experience with this combustion technology and test it for suitability and use in large-scale plant. (orig./KO) [Deutsch] Aufgrund des fortgeschrittenen Alters, der aktuellen Umweltschutzgesetzgebung sowie bestehender Versorgungsverpflichtungen fuer Waerme und Prozessdampf wurde Anfang 1988 von der RWE Energie AG in Essen die ...

1995-12-31

22

Heat management - a technique for resolving the conflicting aims between fuel consumption and comfort; Waermemanagement - ein Werkzeug zur Loesung der Zielkonflikte zwischen Verbrauch und Komfort  

Energy Technology Data Exchange (ETDEWEB)

In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are developed, and the advantages are presented in detail. [German] Abgeleitet aus den Trends in der Fahrzeugentwicklung wird auf den immer staerker werdenden Konflikt zwischen den steigenden ...

1999-07-01

23

Isothermal high-temperature fatigue tests on {gamma}-TiAl in different atmospheres; Isotherme Hochtemperaturermuedungsversuche an {gamma}-TiAl in unterschiedlichen Atmosphaeren  

Energy Technology Data Exchange (ETDEWEB)

{gamma} Ti-Al have a higher temperature potential than commercial titanium alloys and a 50 percent lower density than nickel base superalloys. Application temperatures in aircraft turbines are 750 C and above. The authors investigated the high-temperature performance of {gamma} TiAl, i.e. isothermal high-temperature fatigue and the type and importance of damage. LCF experiments were made in the temperature range of brittle/ductile transition in air and vacuum. Damage mechanisms were characterized by microstructural investigations. [German] Unter den modernen Hochtemperaturwerkstoffen kommt den Legierungen auf Basis von {gamma}-TiAl eine zunehmend wichtige Bedeutung zu, da diese Werkstoffe ein hoeheres Temperaturpotential als alle kommerziellen Titanlegierungen haben und eine im Vergleich zu den Nickelbasis-Superlegierungen um ca. 50% geringere Dichte aufweisen. TiAl-Werkstoffe, die z.B. fuer Schaufeln und Gehaeuse in Flugzeugturbinen eingesetzt werden sollen, muessen ...

1999-07-01

24

The integrity concept of the rack drive electric power steering system; Das Sicherheitskonzept der elektromechanischen Servolenkung mit Zahnstangenantrieb  

Energy Technology Data Exchange (ETDEWEB)

Today electric power steering systems are regularly considered by the car manufacturers as an alternative to a conventional hydraulic power steering system in the development of new vehicle platforms. Simplified vehicle assembly and the potential to contribute to the reduction of the vehicle's energy consumption are the main motivation for this. The performance of the systems available at present with 13.5 V supply voltage will be improved even more as soon as the future 42 V vehicle electrical systems are available. Like most active chassis systems, electric power steering has to meet the highest safety requirements imaginable. This article summarizes the safety philosophy of the TRW rack drive Electric Power Steering system. (orig.) [German] Elektromechanische Servolenkungen werden heute bei der Entwicklung neuer Fahrzeuge als Alternative zur konventionellen hydraulischen Servolenkung in Betracht gezogen. Die vereinfachte ...

1999-11-01

25

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in about 40 organs and tissues of the human ...

2009-10-15

26

Oscillation diagnosis of steam turbines; Schwingungsdiagnose bei Dampfturbosaetzen  

Energy Technology Data Exchange (ETDEWEB)

Modern oscillation- and analysis systems are often mentioned in the context of oscillation diagnosis which implies that this is a method of establishing the causes of the mechanical changes that cause the unwanted oscillation. Experience shows, however, that oscillation monitoring instruments can merely indicate oscillation symptoms at an early point in time. These findings must be interpreted in a machine-specific way and seen in the context of previous developments in order to establish the mechanical root cause of the matter. A 1000 MVA-generator shows that conventional oscillation measuring systems may also serve for diagnostic purposes within certain limits.(orig.) [German] Im Zusammenhang mit modernen Schwingungsmess- und Analysensystemen wird haeufig der Begriff der Schwingungsdiagnose verwandt und inpliziert, damit auch die Ursache von mechanischen Veraenderungen finden zu koennen, welche das beanstandete Schwingungsverhalten hervorruft. In der Praxis zeigt sich, dass dem Stand ...

1998-07-01

27

New technique: recovery of cables without trenching works; Verfahren zur grabungsfreien Bergung von Kabeln  

Energy Technology Data Exchange (ETDEWEB)

Flow Tex and ABB Energiekabel GmbH have developed a technique which allows the recovery of cables without requiring any trenching works. The new technique was successfully used for the first time for a pilot project in 1995. The authors report on two recent recovery projects (1998) in which an optimised technology was used for recovering a total of 1 500 m system length of 110 kV low-pressure oil-filled cables in Stuttgart and Munich on very different conditions. The authors describe the operational experiences with the cable connections and highlight the background stipulating the removal of the cables. (orig.) [Deutsch] Ein Verfahren zur grabungsfreien Bergung von Kabeln, gemeinsam entwickelt von FlowTex und ABB Energiekabel, wurde erstmals in einem Pilotprojekt 1995 mit Erfolg eingesetzt. Die Verfasser berichten ueber zwei Bergungsprojekte, bei denen 1998 mit der optimierten Technik in Stuttgart und Muenchen insgesamt 1 500 Systemmeter ...

1999-03-22

28

High performance materials and precious substances made out off renewable substances, specially animal substances. Final report; Hochleistungswerkstoffe und -wertstoffe aus nachwachsenden Rohstoffen, insbesondere aus tierischen Substanzen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Basic research in relation to a complete utilisation of animal substances as an alternative to a thermal disposal was done. The composition of different kinds of bones were investigated as well as their amounts which are available. Conventional utilisation was opposed to the innovative utilisation. Technologies will be selected which should be developed, because they have the chance in the case of a fast industrial realisation to get a good profit. There is a global requirement for the technologies which are developed and their products which can be produced with this. The raw material basis is available in the necessary scale in nearly all countries. (orig.) [German] Grundlegende Untersuchungen zur ganzheitlichen Verwertung von tierischen Substanzen als Alternative zur thermischen Entsorgung wurden durchgefuehrt. Es wurde die Zusammensetzung der verschiedenen Knochenarten und ihr Aufkommen untersucht. Die konventionelle wurde der innovativen ...

2003-05-08

29

Endoluminal vascular prostheses; Endoluminale Gefaessprothesen  

Energy Technology Data Exchange (ETDEWEB)

Endoluminal vascular prostheses that can be implanted by percutaneous routes represent the most recent development in vascular interventional radiology. Various commercially available types of prosthesis are presented and the construction principles and applications are described. At present secure indications for the implantation of endoluminal prostheses are limited to the elimination of aneurysms and arteriovenous fistulae of the large vessels near the trunk in sections that do not cross a joint. The wide use in peripheral occlusive diseases cannot yet be recommended because confirmed data are not available. (orig.) [German] Endoluminale Gefaessprothesen, die perkutan implantierbar sind, stellen die juengste Entwicklung in der vaskulaeren interventionellen Radiologie dar. Verschiedene kommerziell erhaeltliche Prothesentypen werden vorgestellt, ihr Konstruktionsprinzip und ihre Applikation erlaeutert. Die gesicherten Indikationen zur endoluminalen ...

2000-06-01

30

Utilization of hard-coal mining wastes and red mud for the production of expanded-clay granulate; Verwertung von Steinkohlenwaschbergen und Rotschlamm zur Herstellung von Blaehton-Granulat  

Energy Technology Data Exchange (ETDEWEB)

By using defined compositions based on industrial wastes of the hard-coal mining and a further waste material (red mud), which is obtained during the extraction process of alumina (BAYER-Process), it is possible to produce expanded-clay granulate requiring suitable preparation, shaping and firing at temperatures of about 1150 C. Some of the investigated parameters and aspects of this manufacturing process will be presented in this paper. (orig.) [German] Aus definierten Mischungen industrieller Reststoffe des Steinkohlenbergbaus (Bergematerial) mit einem weiteren Abfallstoff (Rotschlamm), der bei der Aluminiumoxidgewinnung nach dem BAYER-Verfahren anfaellt, laesst sich nach geeigneter Aufbereitung und Formgebung durch Brennen bei ca. 1150 C Blaehton-Grunulat herstellen. Auf einen Teil der untersuchten Parameter und ermittelten Zusammenhaenge soll im folgenden naeher eingegangen werden. (orig.)

1999-07-01

31

Stirling cooler ILK 15 - refrigeration of 15 W at 80 W; Stirlingkuehler ILK 15 - Kaeltemaschine fuer 15 W bei 80 K  

Energy Technology Data Exchange (ETDEWEB)

The stirling cryocooler ILK 15 is a machine with simple drive concept. This machine works with a conventional built-in electric motor and crank drive and needs a power input of about 500 W. The refrigerating capacity is 15 W at 80 K with a cooldown time of 12 minutes. The cooler is somehow a replacement for the Gifford-McMahon cycle coolers, which are bigger and heavier. The Stirling cryocooler was designed to cool HTSC-components. (orig.) [Deutsch] Der Stirlingkuehler ILK 15 ist eine Kaeltemaschine mit einfachem Antriebskonzept. Die Maschine arbeitet mit einem konventionellen Elektroeinbaumotor und Kurbeltrieb. Sie benoetigt eine Antriebsleistung von 500 W und hat eine Kaelteleistung von 15 W bis 80 K und eine Einkuehlzeit von 12 Minuten. Die Maschine kann als Alternative zur wesentlich groesseren und schweren Gifford-McMahon-Maschine gesehen und bei der Kuehlung von HTSL-Komponenten eingesetzt werden. (orig.)

1998-11-01

32

Measurement techniques and measurement opportunities on the spot; Messverfahren und -moeglichkeiten Vorort  

Energy Technology Data Exchange (ETDEWEB)

Verification of guarantees mostly calls for measurements on the spot. The paper deals with the guarantees that apply to small hydroelectric power stations. Already when planning a plant it should be decided what guarantees are to be demanded and how they can be verified. Specifically, measurements to verify guaranteed performance and efficiency on the spot are dealt with. Details are not given. Rather, the report wants to give an overview of methods and aspects to be taken heed of. For in-depth information, the reader is referred to the corresponding standards and guidelines. (orig.) [Deutsch] Zur Ueberpruefung von Garantien ist meistens die Durchfuehrung von Messungen vorort notwendig. Es werden die Garantien behandelt, die bei Kleinwasserkraftanlagen in Frage kommen. Bereits bei der Planung der Anlage sollte entschieden werden, welche Garantien gefordert werden sollen und wie sie ueberprueft werden koennen. Es wird ...

1997-12-31

33

Study of an efficient application of the tagged bremsstrahlung in double-polarization experiments in the GeV range and the use of the inelastic electron scattering under extremely forward angles as alternative to the tagged bremsstrahlung; Studie eines effizienten Einsatzes der markierten Bremsstrahlung bei Doppelpolarisationsexperimenten im GeV-Bereich und der Nutzung der inelastischen Elektronstreuung unter extremen Vorwaertswinkeln als Alternative zur markierten Bremsstrahlung  

Energy Technology Data Exchange (ETDEWEB)

For the preparation of photonic probes for hadron physics the determination of energy and polarization of the photons is essential. In this dissertation in a first part a possibility of the determination of the degree of polarization by use of the asymmetry observables is presented. In a second part a possibility isd discussed to perform an energy and polarization tagging of nearly real photons in electron scattering under small Q{sup 2}. By this method it should be possible to tag billions of photons per second.

2006-03-15

34

Structural integrity of whipping pipes following postulated rupture - a contribution to strain levels acceptable under faulted conditions. Integritaetsverhalten von Rohrleitungen nach unterstelltem Rundabriss - ein Beitrag zur Dehnungsabsicherung bei Schadensfaellen  

Energy Technology Data Exchange (ETDEWEB)

By tests about pipe failure under extreme bending, moment at cross sections affected by circumferential cracks, admissible strains for securing the integrity in the area of a flow link are indicated. These are 7% for austenic and ferritic materials in the undisturbed cross section. From d/t-ratios of 20 onwards the strains are limited by pipe bulging on the pressure-load side. In this connection, circumferential flaws do not have any influence on the behaviour on the strained side, when their expansion does not exceed the investigated limitis of <60 circumferential expansion and crack depth of 0,3 t. (orig.)

1991-01-01

35

Constitutional examinations in the system Fe-Al-Zr; Konstitutionsuntersuchungen im System Fe-Al-Zr  

Energy Technology Data Exchange (ETDEWEB)

Two isothermal sections were prepared at 1000 and 1150 C showing the low-Zr phases of the system Fe-Al-Zr. The phase equilibria were determined by means of X-ray powder diffractometry and electron beam microanalysis. For initial characterisation of mechanical properties, hardness values are determined and added to the tabulated data. (orig./MM) [German] Es werden am Fe-Al-Zr-System zwei isotherme Schnitte durch den zirkoniumarmen Teil des Systems bei 1000 und 1150 C erstellt. Die auftretenden Phasengleichgewichte werden mit Hilfe der Roentgenpulverdiffraktometrie und Elektronenstrahlmikroanalyse aufgeklaert. Zusaetzlich werden zur ersten Charakterisierung der mechanischen Eigenschaften Haertewerte bestimmt.

1999-07-01

36

Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten  

Energy Technology Data Exchange (ETDEWEB)

On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

1990-09-01

37

Extension of adrenal tumors into the vena cava: results of magnetic resonance angiography; Kavazapfen bei Nebennierentumoren: Kernspintomographische Befunde  

Energy Technology Data Exchange (ETDEWEB)

In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in seltenen Faellen eine Tumorausdehnung in die ...

1995-11-01

39

Web-based training in radiology - student course in the Virtual University of Bavaria; Web-basiertes Training in der Radiologie - Studentenkurs in der Virtuellen Hochschule Bayern (VHB)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The nint version of the licensing regulation for medical doctors (Approbation Regulation (AR)) sets a benchmark in terms of practical experience, interdigitation of preclinical and clinical studies, interdisciplinary approach, economic efficiency, independence of students, added new teaching and learning modalities, and ongoing evaluation of the progress of the medical students. It is the aim to implement these major points of the AR in a model course for diagnostic radiology and radiation protection within the scope of the Virtual University of Bavaria and test them in practice. Materials and Methods: In cooperation with residents and board certified radiologists, students developed the virtual course 'Web-Based Training (WBT) Radiology' in diagnostic radiology and radiation protection for students in the first clinical semester. A representative target group taken from the student body was asked about the options to get access to the World Wide Web ...

2004-06-01

40

Requirements, design and development of a latent heat store for use in vehicles; Anforderungen, Konzeption und Entwicklung eines Latentwaermespeichers fuer den Kraftfahrzeugeinsatz  

Energy Technology Data Exchange (ETDEWEB)

With the development of the latent heat store and its inclusion in the conventional heating control of cars, success has been achieved both in increasing comfort and in making an important contribution to safety of driving. Great store is set in development of the system on its environmental friendliness, for example by the thorough use of environmentally friendly and reusable materials. This also means the use of clean materials. It was shown that the latent heat store (apart from the aspects of comfort and safety of driving) can also make a contribution to saving fuel and reducing the exhaust gas. The sum total of the advantages makes it clear that the latent heat store introduced here is a very environmentally friendly system with multi-functional properties. (orig.) [Deutsch] Mit der Entwicklung des Latentwaermespeichers und seiner Einbindung in die konventionelle Heizungsregelung von Automobilen ist es gelungen, sowohl den Komfort deutlich zu erhoehen als auch einen wichtigen ...

1994-12-31

41

Crack resistance in ceramic fibre compound materials; Risswiderstand in keramischen Faserverbundwerkstoffen  

Energy Technology Data Exchange (ETDEWEB)

The fibre reinforcement of ceramic materials is used above all to improve the toughness and tolerance of damage, compared to unreinforced monolithic ceramics. This improvement is made possibly by the bridging effect of the cracks by the fibres in crack propagation in the matrix. In this work, the crack bridging effect of the fibres is included in a bridge stress equation, in which a clear relationship between bridge stress and crack opening is determined. The most important step for deriving the bridge stress law was determining the probability of failure of a fibre for a given axial stress curve. One relied on the micromechanical analysis of Hutchinson and Jensen here, by which the boundary conditions in multi-fibre materials can be included and realistic assumptions can be made for the load transfer mechanisms in the fibre/matrix boundary surface. (orig./MM) [Deutsch] Die Faserverstaerkung keramischer Werkstoffe dient vor allem zur Verbesserung der Zaehigkeit und ...

1995-03-01

42

Processing and physical utilisation of waste materials relevant to iron and steel manufacture; Aufarbeitung und stoffliche Nutzung eisen- und stahlrelevanter Abfallstoffe  

Energy Technology Data Exchange (ETDEWEB)

A part of the waste materials arising in iron and steel manufacture is utilised physically, either internally for the recovery of iron or externally for the production of cement and nonferrous metals. Most of these materials can be used without prior processing. Iron and steel-relevant waste materials which at present are still landfilled or disposed of as hazardous wastes are not immediately suitable for physical recycling as secondary raw material. These waste materials have to be processed without exception before they can be used again in the existing steel and iron manufacturing plants. The results of the authors` own studies have clearly shown that the cupola furnace is suited for the use of a wide variety of waste materials. [Deutsch] Ein Teil der bei der Eisen- und Stahlerzeugung anfallenden Abfallstoffe werden entweder intern zur Rueckgewinnung des Eisens oder extern in der Zement- bzw. Nichteisenmetallgewinnung stofflich verwertet. ...

1998-09-01

43

A thermographic method as an alternative for gravimetric determination of the particulate diesel emissions; Ein thermographisches Messverfahren als Alternative zur Gravimetrie bei der Ermittlung von Dieselpartikel-Emissionen  

Energy Technology Data Exchange (ETDEWEB)

The basis of assessment for particulate exhaust emissions is the gravimetric analysis of the particle concentration of diluted exhaust gases at temperatures below 52 C. This is very time consuming and takes sufficient sensitivity at low particulate emission rates like downstream of particle filters. For this reason the C/S-method, based on the thermographic analysis of carbon and sulfur, has been developed as an alternative to the gravimetric anallysis. This method yields particle mass as well as the main particle compounds. Comparisons between both methods have been carried out for heavy duty and automobile diesel engines as well as road vehicles and large diesel engines. The tests were conducted with commercial diesel fuel and also with other fuels, such as heavy oils. It could be shown that the C/S-procedure yields the same results as the gravimetric procedure independent of engine, engine mode and kind of fuel. The analysis of all important particulate compounds - elemental carbon ...

1995-09-01

44

State and development of uterine myoma embolization in Germany; Stand und Entwicklung der Uterusmyomembolisation in Deutschland  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical evaluation by ultrasound and MRI, preferable location of treatable fibroids, technical ...

2003-08-01

45

Von Roll RCP method - first experiences; Von Roll RCP - Verfahren. Erste Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

The RCP method was designed as a residue-optimised alternative to the thermally optimised grate firing of residual wastes. Its technical realisation and development to market maturity took no more than 5 years. In the first process stage the waste is converted to high-carbon pyrolysis charcoal and high-rank gas in the absence of oxygen. In the second stage these substances are oxidised by addition of oxygen. The resulting temperature causes the non-combustible constituents of the slag to melt. In a third, optional, stage this molten slag can be liberated of (heavy) metals to such an extent that it can subsequently be used directly as additive for grinding. Further exhaust gas treatment is facilitated by the use of a circulatory fluidised-bed secondary combustion chamber. Despite the reduced flue gas volume and resultant higher pollutant concentrations in the crude gas, overall emissions are lower than in conventional plants. [Deutsch] Das reststoffoptimierte RCP Verfahren ist als ...

1998-09-01

46

Steam turbine blade damage; Schaeden an Dampfturbinenbeschaufelungen  

Energy Technology Data Exchange (ETDEWEB)

Blades of modern steam turbines are designed for high efficiency and operational safety. Modern computer programs enable optimisation of design but factors like manufacturing, assembly, operation and downtimes still play an important role. Damage statistics show that blade damage still quite frequent. Selected cases from the Allianz damage assessment centre show some of the more frequent damage mechanisms. Damage is often caused when several factors come together. Prevention of follow-up damage requires early identification of beginning damage.(orig.) [German] Die Auslegung der Beschaufelung moderner Dampfturbinen hat die Vorgabe, einen hohen Wirkungsgrad bei gleichzeitig hoher Betriebssicherheit zu erreichen. Mit den heute zur Verfuegung stehenden Rechenprogrammen ist eine entsprechende Optimierung realisierbar. Fuer die langzeitige Betriebsbewaehrung haben aber Einflussgroessen aus Fertigung, Montage, Betrieb und Stillstand auch heute noch ...

1998-07-01

47

Simulation of char combustion according to shrinking particle and shrinking core model in circulating fluidized bed boilers; Simulation des Koksabbrandes nach dem Shrinking Particle- und Shrinking Core Modell in zirkulierenden Wirbelschichtfeuerungen  

Energy Technology Data Exchange (ETDEWEB)

The presented paper describes the formulation of the fractional mass balances which are used to calculate the concentration and size distribution of char in the balance cells of a circulating fluidized bed boiler. In case of using the shrinking core model additionally the distribution of conversion of the char particles is calculated. Basically two reaction models (a shrinking particle and a shrinking core model) are available to describe the combustion process. The model considers all essential physico/chemical phenomena (primary fragmentation, attrition, mass transfer to gas phase) which have to be taken into account for the description of the combustion process. The model is part of an overall simulation program for circulating fluidized bed boilers. This engineering simulator has been developed to return the main performance parameters of such systems like temperature along the furnace height, size distribution of balanced solid components, heat flows at the different heat ...

1998-12-31

48

Energy conservation, an economically efficient way of air pollution abatement. Economic arguments in air pollution policy; Energiesparen - Klimaschutz, der sich rechnet. Oekonomische Argumente in der Klimapolitik  

Energy Technology Data Exchange (ETDEWEB)

Experts tend to disagree about the economic effects of air pollution abatement measures. This book, which addresses also non-experts, explains the analytical background on the basis of available data. The authors conclude that there is a wide range of political options for achieving the goal of air pollution abatement. They differentiate between the various levels of discussion and show how misinterpretations of scientific results come about, thus making an important contribution to a discussion that is based on facts rather than emotions. [German] Die Einschaetzungen zur wirtschaftlichen Bewertung von Klimaschutzmassnahmen, insbesondere zur Steigerung der Energieeffizienz, sind sehr widerspruechlich. Dieses Buch erlaeutert anhand von Zahlenmaterial die analytischen Hintergruende und ist auch fuer Nicht-Oekonomen verstaendlich geschrieben. Die Autoren kommen zu dem Schluss, dass in vielen Bereichen rentable Energiesparpotentiale nicht erkannt ...

2000-07-01

49

Repairing directionally solidified and single-crystalline gas turbine blades; Reparatur von gerichtet erstarrten und einkristallinen Gasturbinenschaufeln  

Energy Technology Data Exchange (ETDEWEB)

Investigations show that nickel-based alloys (MAR M 247 CC, CM DS 247 L and CMSX-4) can be successfully brazened. Tensile tests of MAR M 247 CC samples brazened with foil brazing showed values comparable to those of the base material, some samples failed because of base material problems. Tests with powder mixes made up from commercial brazens and the base material CMSX-4 showed good wetting and a perfect microstructure similar to the base material. Tensile test values at RT (test temperature) and 850 degrees centigrade show pronounced scatter. Tensile tests at RT and 850 degrees centigrade are used to optimse brazing cycles for the types of brazen used (temperature, time). (orig.) [German] Die Untersuchungen haben gezeigt, dass es moeglich ist, Nickelbasislegierungen (MAR M 247 CC, CM DS 247 LC und CMSX-4) erfolgreich zu loeten. Die im Zugversuch erhaltenen Festigkeitswerte der mit folienfoermigen Lot geloeteten MAR M 247 CC Proben erreichten Werte nahe der Festigkeit des ...

1998-07-01

50

New placement of TIPS during pregnancy for recurring esophageal variceal bleeding: Estimation of fetal radiation exposure; TIPS-Neuanlage in der Schwangerschaft bei rezidivierender Oesophagusvarizenblutung - Abschaetzung der fetalen Strahlenexposition  

Energy Technology Data Exchange (ETDEWEB)

Recurrent variceal bleeding due to liver cirrhosis led to treatment with a transjugular intrahepatic portosystemic shunt (TIPS) in a pregnant woman at 20 weeks` gestation. Fetal radiation exposure was estimated to be less than 10 mSv. The use of a graduated catheter allowed measurement of field size and reliable determination of the patient`s entrance dose. Radiation exposure of an approximated fetal dosage of 5.2 mSv did not justify abortion for medical reasons. Therefore, TIPS procedure is not generally contraindicated during pregnancy itself. TIPS placement may be a therapeutic option related to the severity of the underlying maternal disease, after radiation exposure of the fetus has been estimated. (orig.) [Deutsch] Bei rezidivierender Oesophagusvarizenblutung auf dem Boden einer Leberzirrhose wurde bei bestehender Schwangerschaft der 20. Woche ein transjugulaerer portosystemischer Stent-Shunt (TIPS) neu angelegt. Praeinterventionell wurde ...

1998-10-01

51

Lacrimal gland masses on CT and MRI: a report of four cases; Raumforderungen der Traenendruese in CT und MRT am Beispiel von vier Faellen  

Energy Technology Data Exchange (ETDEWEB)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten bei Traenendruesenraumforderungen berichtet (Lymphom, pleomorphes Adenom, ...

1995-11-01

52

Heating system maintenance over the telephone. Remote control and maintenance of heating systems; Die Heizung am Telefon. Fernueberwachung und Fernparametrierung von Heizungsanlagen  

Energy Technology Data Exchange (ETDEWEB)

The low budgets of local governments and Federal States in Germany as well as lack of financial means of renters delaying thorough modernisation of existing heating systems in residential and public buildings, novel heat supply and related customer services are emerging on the market. Heat supply companies and housing construction associations increasingly use modern electronics and telecommunication systems for heating system upgrading and reliable operation and maintenance. This option holds an enormous potential of saving money today and in the future. Installation of remote control and maintenance systems and the related telephone-based services offer fast repair and other services via electronic telecommunications systems, thus saving money and manpower for the repair services of heat suppliers or plumbers, or financial losses due to rents being docked for broken down heating systems. Such remote control and maintenance systems however need to be reasonable in price, and versatile ...

1997-11-01

53

Biosorption of heavy metals under anaerobic conditions. Final report; Biosorption von Schwermetallen unter anaeroben Bedingungen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The precipitation of heavy metals as hydroxides is the standard technique for the decontamination of waste water streams polluted by these elements. On the other side, progress in research has been made concerning the biosorption onto dead biomass and bioprecipitation supported by physiologically active bacteria. As the aim of this study, a flexible strategy has been envisaged cleaning a waste water with definite heavy metal load underlying the process mentioned above. Suitable bacteria were enriched and the process was tested in a technical plant. As result, a very high efficiency of heavy metal elimination has been found. The field of application covered by the acquired process is identical with the whole range of the waste water streams polluted by heavy metals. In addition, a second stage may be necessary if there are any further contaminants to be removed. (orig.) [Deutsch] Bei der Reinigung von schwermetallhaltigen Abwaessern ist der derzeitige Stand der ...

1996-12-31

54

Neoadjuvant vs adjuvant pelvic radiotherapy for locally advanced rectal cancer: Which is superior?  

UK PubMed Central (United Kingdom)

The treatment of locally advanced rectal cancer including timing and dosage of radiotherapy, degree of sphincter preservation with neoadjuvant radiotherapy, and short and long term effects of radiotherapy...Full Text Available

2011-02-21

55

Investigations into the behaviour of chlorohydrocarbons with a view to thermal waste processing; Verhalten von Chlorkohlenwasserstoffen in Hinsicht auf die thermische Muellverwertung  

Energy Technology Data Exchange (ETDEWEB)

Pyrolysis and combustion of CH are investigated. In order to reduce the work required for the present combination of parameters, the following substances were selected: Hexachloroethane, hexachlorocyclohexane, hexachlorobenzene and hexachlorophene. The model substances were pyrolyzed or combusted in varying conditions, and the combustion or pyrolysis products were analyzed. Only the main products were of interest; trace components are important only as far as they may throw light on the reaction mechanisms. The furnace design resulted in incomplete combustion and pyrolysis reactions, so that products of all stages of combusition or pyrolysis were available for analysis. Reaction processes can be derived from the products. As an alternative to thermal treatment of refuse, biological degradation of chlorinated hydrocarbons was gone into. The efficiency of decomposition by microorganisms was to be compared with the efficiency of thermal destruction of chlorohydrocarbons. The ...

1993-07-01

56

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. (orig./MG) [Deutsch] Zuerst wurde an ...

1996-05-01

57

Measurement of level lifetimes in the ps range and model interpretations for neutron-rich A {approx_equal} 100 nuclei  

Energy Technology Data Exchange (ETDEWEB)

The nuclear structure of A {proportional_to} 100 nuclei has been studied in the frame of this thesis with a recently developed {beta} - {gamma} - {gamma} triple coincidence fast timing technique and different models such as shell model, hydrodynamic model, Nilsson and particle-rotor models. This technique which allows the measurement of the level lifetimes in the ps range has been applied at JOSEF at the research reactor DIDO of KFA Juelich in studes of the short-lived neutron-rich nuclei in the A {approx_equal} 100 region. Lifetimes of level in {sup 96},{sup 98},{sup 100} ZR, {sup 99},{sup 101}-{sup 104} Nb, {sup 100}-{sup 105} Mo have been measured, which are in many cases completely new, and otherwise more precise than previously published data. From the lifetimes of the members of rotational bands, the size of the nuclear deformations has been deduced. (orig./HSI). [Deutsch] Im Rahmen dieser Doktorarbeit wurde die Kernstruktur der A {proportional_to} 100 Kerne untersucht. Dazu ...

1992-08-01

58

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to ...

2000-08-01

59

MR-based volumetric analysis of small tumor volumes: accuracy of phantom examinations of simulated eye tumors; Evaluierung der MR-Volumetrie kleiner Volumina am Beispiel von Augentumoren mittels Phantomuntersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of tumors. ...

2003-07-01

60

HDR and MDR intracavitary treatment for carcinoma of the uterine cervix. A prospective randomized study  

Energy Technology Data Exchange (ETDEWEB)

Aim: Treatment of carcinoma of the uterine cervix by remote afterloading brachytherapy has been accompanied with new isotopes having dose rates different from the classical low-dose rate (LDR) radium source. The dose rate conversion factor from LDR to high-dose rate (HDR) found to be around 0.54 in most studies. As regards medium-dose rate (MDR) brachytherapie, the published data are very few and the experience is still short. In this study the experience of Osaka University Hospital with micro-HDR-Selectron and Selectron-MDR, as a preliminary report of the clinical trial, is presented. Results: The 3-year survival and loco-regional control rates for both modalities were nearly equivalent (62% and 67% for HDR and 68% and 74% for MDR)(totally 45 patients). The cumulative rectal and bladder complication rates were the same in both groups (29% at 3 years), with only 1 patient (MDR-group) developed grade 3 rectal and bladder complication. In this study, point A dose rate correction factor ...

1997-03-01

61

An extended CT scale technique for evaluating periprosthetic bone lesions - an in vitro study; Extended-field CT-Technik zur Evaluation von periprothetischen Knochenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could be observed. This made it impossible to detect a 1 mm drill in 1 vitallium and in 1 ...

2001-12-01

62

Sprengel deformity in a nine-year-old boy: diagnosis and therapy; Sprengel-Deformitaet bei einem neunjaehrigen Jungen: Diagnostik und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Sprengel deformity is a congential malformation with usually unilateral elevation and medial rotation of the scapula. An omovertebral bone is generally present. Associated skeletal malformations are frequently present. Though functional impairment is mild, the cosmetic and psycho-social impairment can be considerable. The prognosis of early surgical therapy is good. The presented case also justifies surgical correction in the older child. (orig.) [German] Die Sprengel-Deformitaet ist eine angeborene Fehlbildung mit meist einseitiger Elevation und Medialrotation der Skapula. Meist ist ein Os omovertebrale vorhanden. Assoziierte skelettale Fehlbildungen sind haeufig. Obgleich funktionell wenig einschraenkend, ist die kosmetische und psycho-soziale Beeintraechtigung oft erheblich. Die Prognose der fruehen operativen Therapie ist gut. Der vorliegende Fall ermutigt zur operativen Therapie auch im hoeheren Kindesalter. (orig.)

2003-02-01

63

Reducing magnetic fields. Magnetic fields of high-voltage transmission lines or in residential buildings can be largely reduced; Magnetische Felder reduzieren. Bei Hochspannungsleitungen und in Wohnungen lassen sich magnetische Felder weitgehend kompensieren  

Energy Technology Data Exchange (ETDEWEB)

Magnetic fields can be compensated by opposing fields. This principle can be applied for reducing the magnetic fields emanating from high-voltage transmission lines or found in residential or commercial buildings. The article shows a number of concrete options for reducing magnetic fields in the vicinity of high-voltage lines through appropriate conductor configuration on the one hand, and a novel method using Helmholtz coils for compensating those fields in buildings. (orig.) [Deutsch] Magnetische Felder koennen durch Gegenfelder kompensiert werden. Dieses Prinzip laesst sich sowohl auf Hochspannungsleitungen als auch auf Wohn- und Arbeitsraeume uebertragen. Der Artikel zeigt konkrete Moeglichkeiten, wie einerseits Magnetfelder von Hochspannungsleitungen durch eine geeignete Konfiguration der Leiter reduziert werden koennen, und beschreibt andererseits eine neue Methode zur Reduktion solcher Felder in Wohn- und Arbeitsraeumen mittels Helmholtz-Spulen. (orig.)

1997-10-17

64

More efficient combined energy systems. Improved efficiency of combined energy systems using fuel cells; Effizientere Verbundsysteme. Mehr Effizienz bei Energieverbundsystemen durch den Einsatz von Brennstoffzellen  

Energy Technology Data Exchange (ETDEWEB)

Efficiency of energy coversion of primary energy to an end use in industrial countries is about 30%. This is insufficient. Evaluating on basis of exergy efficiency becomes only about 15%. Usage of fuel cells give a great chance to improve efficiency. This concerns in particular to high temperature fuel cell systems SOFC and MCFC as well as their combination with heat pumps. [German] Die Effizienz der Energieversorgung in Industrielaendern ist energetisch bewertet mit rund 30 % unbefriedigend. Legt man den strengeren, energiewirtschaftlich treffenderen exergetischen Massstab an, halbiert sich dieser Wert sogar. Brennstoffzellen bieten durch ihren Einsatz Moeglichkeiten zur Effizienzerhoehung. Dies gilt insbesondere fuer die Hochtemperatursysteme SOFC und MCFC sowie deren Verbund mit Waermepumpen.

2001-07-01

65

Legal problems arising in the decommissioning of uranium mines and the rehabilitation and reclamation of abandoned uranium mining areas in eastern German; Rechtsprobleme der Stillegung von Uranbergwerken sowie der Sanierung und Rekultivierung uranbergbaulicher Hinterlassenschaften in Ostdeutschland  

Energy Technology Data Exchange (ETDEWEB)

Rehabilitation of the abandoned uranium mining areas in Saxonia and Thuringia is a task posing also legal problems. The radiation protection laws of the former GDR continued to be effective to a great extent and proved to be a legal basis not ``perfect`` in formal terms, but suitably efficient in practice to tackle the manifold problems encountered in the land reclamation and waste disposal work. Originally intended to serve as a legal interim regime awaiting amendment at a later date, the body of laws available for the task proved to be a sufficient basis. (orig./HP) [Deutsch] Das fortgeltende Strahlenschutzrecht der frueheren DDR hat sich zwar nicht als formal `perfektes`, in der Sache aber strahlenschutzgerechtes und praktikables Instrument zur Loesung der anstehenden Sanierungsaufgaben erwiesen. Bei seiner Beurteilung darf nicht ausser Acht gelassen werden, dass die Ueberleitung dieses Rechts seinerzeit aus der Not eines kurzfristigen ...

1995-12-31

66

Investigation of the failure rate of hydraulic dashpots; Untersuchung der Ausfallrate an hydraulischen Stossbremsen  

Energy Technology Data Exchange (ETDEWEB)

The failure rate of dashpots has been determined on the basis of the results of annually recurring function tests on hydraulic dashpots, in order to determine the effects of longer test cycles on the safety of systems GKN I and GKN II. The use of a calculation method made it possible to establish the number of defective dashpots in the system as a whole. A subsequent investigation illustrated the way in which this figure changes when the test interval is increased from four to ten years, and the effects of this on system safety. (orig.) [Deutsch] Zur Ermittlung der Auswirkungen verlaengerter Pruefzyklen auf die Sicherheit der Anlagen GKN I und GKN II wurde, basierend auf Ergebnisse der jaehrlichen Funktionspruefung an hydraulischen Stossbremsen, die Fehlerrate der Stossbremsen bestimmt. Mit Hilfe eines Berechnungsverfahrens konnte die Anzahl maengelbehafteter Stossbremsen in der Gesamtanlage bestimmt werden. Eine anschliessende Untersuchung zeigte, wie sich dieser ...

1997-08-01

67

Ground source heat for heat pumps; Erdgekoppelte Waermequellen fuer Waermepumpen  

Energy Technology Data Exchange (ETDEWEB)

Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt eine Schaetzung zu einem Potential der erdgekoppelten Waermepumpen zur Substition von Endenergie von 1310-1470 PJ/a. Ob dieses ...

1996-12-31

68

Experience with the operation and fuel supply of the biomass firing plant of the Trocknungsgenossenschaft Lengenfeld eG, a drying cooperative society; Erfahrungen mit Betrieb und Brennstoffbereitstellung der Biomassefeuerung der Trocknungsgenossenschaft Lengenfeld eG  

Energy Technology Data Exchange (ETDEWEB)

The pilot project of the conversion of the green forage drying plant Lengenfeld to biomass firing could not be realized without problems. But the experience until now shows that it is in principle possible. The farmers involved are devoted to the project. For them the cultivation of biomass is an alternative to the abandonment of fields. The present low oil price sets limits to the positive income effect. The aim is an increase of the biomass share in heating energy supply to about 80%. (orig.) [Deutsch] Die Umstellung der Gruenfuttertrocknung Lengenfeld auf Biomassefeuerung ist als Pilotprojekt nicht ohne Probleme moeglich gewesen. Die bisherigen Erfahrungen zeigen jedoch die grundsaetzliche Praktikabilitaet. Die beteiligten Landwirte sind engagiert bei der Sache und schaetzen die Produktionsmoeglichkeit als Alternative zur Flaechenstillegung. Der derzeit niedrige Oelpreis setzt der positiven Einkommenswirkung jedoch enge Grenzen. Eine ...

1994-12-31

69

Air conditioning with multi-split systems; Klimatisierung mit Multi-Split-Anlagen  

Energy Technology Data Exchange (ETDEWEB)

Modernisation of older office buildings commonly includes installation of air conditioning systems as good air quality and thermal comfort will improve the staff`s efficiency at work. However, what about tenants who want their own, individually controlled single-storey air conditioning plang? And what about retrofitting further storeys with single-storey air conditioning? An exemplary solution to this problem was found in Hamburg. (orig.) [Deutsch] Bei der Sanierung aelterer Buero- und Geschaeftshaeuser werden die Raeume immer haeufiger mit Klimaanlagen ausgestattet. Ein Grund fuer den Trend zur Klimatisierung: Gute Luftqualitaet und angenehme Temperaturen erhoehen die Leistungsfaehigkeit des Menschen. Was aber, wenn ein Mieter fuer seine Bueroetage eine eigene, individuell steuerbare Klimaanlage wuenscht? Und was passiert, wenn andere Bueroetagen mit weiteren Klimaanlagen nachgeruestet werden? In Hamburg wurde dieses Problem auf beispielhafte ...

1998-09-01

70

The decision in lawsuit C-458-00 concerning Strasbourg waste incineration plant. The underlying waste management situation as seen from the viewpoint of the Grand Duchy of Luxembourg; Die Entscheidung im Verfahren C-458/00 MVA Strassburg. Abfallwirtschaftliche Hintergruende aus Sicht des Grossherzogtums Luxemburg  

Energy Technology Data Exchange (ETDEWEB)

The European Court of Justice has defined a clear means by which waste utilisation methods can be distinguished from waste disposal methods in a logical, well-understandable manner. With its stringent definition of ''utilisation'' this judgement points the way to quality-oriented waste management practices. We do not share the often voiced fear that this decision will lead to an increased incineration of compound wastes in industrial plants such as cement works. From the fact that, according to the decision by the European Court of Justice, wastes destined for utilisation fulfil a certain purpose and therefore, if not available in sufficient quantity must be replaced by primary raw materials, it follows that these wastes are required to fulfil specific quality criteria. This is rarely the case, if at all, with compound wastes. From the viewpoint of Luxembourg the decision by the European Court of Justice can be regarded as a positive impulse towards ...

2004-07-01

71

Stepped reforming - a new method for recovering energy and hydrogen from biogenic residues; Die Gestufte Reformierung - ein neues Verfahren zur Gewinnung von Energie und Wasserstoff aus biogenen Reststoffen  

Energy Technology Data Exchange (ETDEWEB)

DMT has developed what is called the stepped reforming process. This is an allothermal gasification process which uses hydrogen for a gasification medium. First the biomass is pyrolised by means of a heat transfer material. The escaping gaseous and condensable constituents are hydrogenated, heated in a reforming stage and are made to react to a hydrogen-rich product gas by means of homogeneous gasification. The heat required for this is provided by burning the pyrolysis coke. This makes it possible to dispense with process stages that would involve gasification of solid material and hence require higher pressure levels. The present process also works at ambient pressure. Moreover, stepped reforming promises a number of additional advantages: low-tar product gas containing 60% hydrogen, high cold gas efficiency, no wastewater arisings, robust operating behaviour. This paper outlines the basic ideas that led to the development of stepped reforming process and describes its diverse ...

2000-07-01

72

Radiological diagnosis of lesions of intervertebral discs; Radiologische Diagnostik von Bandscheibenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens gelingt mit der CT, die parallel zum Bandscheibenfach durchgefuehrt ...

2003-03-01

73

Isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food; Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln mittels eines Strontium-spezifischen Extraktionsharzes  

Energy Technology Data Exchange (ETDEWEB)

A procedure is described for the isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO{sub 4}, Ba(Ra)SO{sub 4} and PbS are prepared. Ra is determined by gamma-spectrometry, {sup 90}Sr and {sup 210}Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for {sup 90}Sr and {sup 210}Pb and 50 mBq/kg for {sup 226}Ra and {sup 228}Ra. The procedure is useful for all kinds of foodstuff. (orig.) [Deutsch] Es wird ein Analysengang zur Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln beschrieben. Ein Merkmal dieser Nuklide ist ihre hohe ...

1996-12-31

74

Formation of damage symptoms to assess the safety margin of components in the high temperature range; Die Entwicklung von Schaedigungsmerkmalen zur Beurteilung der Sicherheitsspanne von Bauteilen im Hochtemperaturbereich  

Energy Technology Data Exchange (ETDEWEB)

Surface structure analysis, i.e. metallographic analysis of component surfaces with the aid of replicas, is an established method of component monitoring and the only reliable non-destructive method for detecting and analyzing beginning creep damage in the form of creep pores. Creep pore development provides a basis for component condition analysis. It must be noted, however, that the modern martensitic 9-12 % Cr steels - like the established steels 10CrMo9-10 (P22) und X20CrMoV12-1 - have comparatively high creep fracture deformation rates in fatigue tests. This raises the question if these steels can be judged on the basis of data for established steels. The results so far suggest that even with low pore densities (single pores), a higher degree of damage and a shorter time until failure must be assumed. [German] Eine bewaehrte Methode der Bauteilueberwachung stellt die Oberflaechengefuegeuntersuchung, d. h. die metallografische Untersuchung der Bauteiloberflaeche mit Hilfe von ...

2005-07-01

75

Eigenschaften von Atomuhren und ihre Verwendung bei der Zeitskalenherstellung  

CERN Document Server

Eigenschaften von Atomuhren und ihre Verwendung bei der Zeitskalenherstellung

1991-01-01

76

TRITEX. A ferritic steel loop with Pb-15.8Li. Facility and operation  

Energy Technology Data Exchange (ETDEWEB)

TRITEX was a pumped loop with Pb-15.8Li, fabricated from steel 1.4922. In contact with the molten eutectic were also molybdenum, vanadium and armco-iron. The loop was originally designed to investigate tritium extraction using solid getter metals. Over the years the goal changed to the study of metals, corrosion products and purification of the eutectic mixture. Therefore many modifications were done. The first part of this report describes TRITEX. All parts were enclosed in thermoboxes for a homogeneous temperature. One test section was in an argon glove box and could be opened during operation. Other special equipment`s were: permeation membranes and liquid-metal-covergas-interfaces to study the transport of H{sub 2}, D{sub 2} and {sup 3}H, different purification devices, a quartz observation window to see the liquid metal surface, 4 different kinds of flow measurements, level indicators, freeze valves. The second part describes loop operation. Between 1989 and 1996, the eutectic ...

1999-05-01

77

Emission control at stationary sources in the Federal Republic of Germany. Vol 1. Sulphur oxide and nitrogen oxide emission control; Massnahmen zur Emissionsminderung bei stationaeren Quellen in der Bundesrepublik Deutschland. Bd. 1. Minderung der SO{sub 2}- und NO{sub x}-Emissionen  

Energy Technology Data Exchange (ETDEWEB)

The first volume of the report covers the state of implementation of primary and secondary measures for SO{sub 2}- and NO{sub x} control applied in the most important industrial sectors in Germany. Integrated pollution abatement techniques, called primary measures in this report, such as process integrated measures and low emission processes, have gained increased importance in recent years. The end-of-pipe processes, described here as secondary measures, are generally highly effective. They represent mature technologies, which are capable of achieving significant reductions in SO{sub 2}- and NO{sub x} emissions, and which have been used in particular for retrofitting existing plants. At first, an overview is given regarding the development of SO{sub 2}- and NO{sub x} emissions in selected European countries during the last 20 years and in Europe. Current national and European emission limits and emission guidelines on SO{sub 2}- and NO{sub x} emissions from stationary sources are ...

1997-05-01

78

Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART); Perkutane Therapie inoperabler maligner Stenosen und Verschluesse der Gallenwege mit einem neu entwickelten selbstexpandierbaren Nitinolstent (SMART)  

Energy Technology Data Exchange (ETDEWEB)

Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% (n=15) of patients ...

2002-10-01

79

Turbine blade protective coat damage; Schutzschichtschaeden an Gasturbinenschaufeln  

Energy Technology Data Exchange (ETDEWEB)

Damage survey of protective coats of modern gas turbine blade shows that most damages are not due to classic wear mechanisms such as oxydation or high-temperature corrosion but caused by foreign bodies, poor coating during manufacturing, or operation-caused cracks. Mere visual inspection of cracks is often not sufficient to tell whether cracks are superficial or whether they have already progressed into the base material. Non-destructive methods such as ultrasonic inspection or eddy-current testing are helpful tools but there is not yet a fully matured testing concept at hand. Metallographical tests can give important information about crack mechanisms and thermal, chemical and mechanical stresses.(orig.) [German] Die Schadenerfahrung mit Schutzschichten moderner Gasturbinenschaufeln zeigt, dass die meisten Schaeden nicht auf die klassischen Verbrauchsmechanismen wie Oxydation und Hochtemperaturkorrosion zurueckzufuehren sind, sondern durch Fremdkoerper, herstellungsbedingte ...

1998-07-01

80

The steam generation yearbook. 7th edition; Jahrbuch der Dampferzeugungstechnik. 7. Ausgabe  

Energy Technology Data Exchange (ETDEWEB)

This 7th edition reveals the progress in steam engineering and the great future potential of steam engineering applications. Pollution abatement and design experiences gained during the operation of existing plants, and experiences gained in waste incineration are of environmental relevance. Recent materials developments and knowledge, e.g. as regards pipes and fittings, have been making significant contributions to supercritical-steam efficiency improvements. Emphasis is also placed on automation, control engineering, water chemistry etc., and on regulations, licensing procedures, and the training of the staff of plants. (orig./KOW) [Deutsch] Die nunmehr vorliegende 7. Ausgabe zeigt den Fortschritt und das zukuenftig noch erhebliche Potential dieser Technik auf. Erfahrungen mit den nun schon seit Jahren laufenden Anlagen zur Schadstoffminderung, Konstruktion und Auslegung sowie Betriebserfahrungen zur thermischen Abfallverwertung sind ...

1992-12-31

81

Mobile leakage detection with absorbed tracer without supply disconnection; Mobile Lecksuche mit geloesten Tracern ohne Versorgungsunterbrechung  

Energy Technology Data Exchange (ETDEWEB)

For location of leakage at district heating pipelines several techniques are available today. If there is no wire bound lead monitoring system installed, the DH company has to apply mobile methods for detection and location and if possible characterization of leakage. Most mobile methods available today are restricted in application and often they cause supply disconnections, especially the location of very small leaks is difficult. The Institute for Environmental, Safety and Energy Technology (UMSICHT) has tested a new developed method that can be executed by own employees of DH companies that can be realised parallel to normal supply mode, and that is able to locate and characterize even very small leakages. (orig.) [Deutsch] Zur Lecksuche an Fernwaermeleitungen stehen verschiedene Techniken zur Verfuegung. Wurde beim Bau der Fernwaermetrasse kein drahtgebundenes Ueberwachungssystem eingebaut, ist der Netzbetreiber auf mobile Lecksuchmethoden ...

1997-06-01

82

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur offenen chirurgischen ...

2008-09-15

83

European codes for the fire protection design of building constructions - overall view, principles and responsible authority treatment; Eurocodes fuer die Brandschutzbemessung von Baukonstruktionen. Uebersicht, Prinzipien und bauaufsichtliche Behandlung  

Energy Technology Data Exchange (ETDEWEB)

With publication the fire design rules of the Eurocode and the national application documents (NAD) for the first time also calculation methods of constructive structural fire protection are available. This dimensioning of components and structures in fire case is based on the normal temperature design on Eurocodes and can be applied in the future as alternative to the classical fire design method of the German standard DIN 4102 part 4. In this contribution a view of the proof procedures of the Eurocode fire protection parts and the arrangements of the NADs is given as soon as the application of these fire design rules in Germany is described. (orig.) [German] Mit der Veroeffentlichung der Eurocode-Brandschutzteile als Vornormen und der zugehoerigen nationalen Anwendungsregelungen (NAD) als DIN-Fachberichte stehen erstmals auch rechnerische Nachweisverfahren fuer den konstruktiven baulichen Brandschutz zur Verfuegung. Diese brandschutztechnische Bemessung von ...

2000-12-01

84

VACUJET-process - high pressure water jet technology with broad application potential; VACUJET-Verfahren - Wasserhoechstdrucktechnik mit grossem Einsatzpotential  

Energy Technology Data Exchange (ETDEWEB)

When performing trenchless pipe renovation work - whichever process you use - the success of the job depends on the careful removal of all scale, sediments and rust from the innerwall surfaces. The VACUJET process - in which the pipe is cleaned with water at pressures of up to 2 500 bar using a technique jointly developed by Preussag Rohrsanierung GmbH and Fabex GmbH - meets all requirements. The equipment includes a mobile waste water treatment unit which is small enough to fit on a standard trailer. Despite its compact dimensions this plant is so effective that it can treat all the waste water generated during the high pressure cleaning jobs so that it is suitable for reuse in the cleaning process or for release into the sewerage system. (orig.) [Deutsch] Bei der grabenlosen Rohrsanierung, ganz gleich nach welchem Verfahren saniert wird, ist die sorgfaeltige Entfernung von alten Beschichtungen, Ablagerungen und Rost eine wesentliche Voraussetzung fuer den ...

1998-12-31

85

Production of olefins from recycling polyolefins by means of thermal steam cracking; Olefinerzeugung aus Recycling-Polyolefinen durch thermische Dampfspaltung  

Energy Technology Data Exchange (ETDEWEB)

As one of the largest contractors for the construction of ethylene plants featuring steam cracker furnaces as their core component Linde AG has examined the `real` chemical recycling of polymers in steam cracker furnaces as an alternative to their thermal utilisation. In steam cracker furnaces the feedstock, i.e., hydrocarbons, is broken down to ethylene, propylene, and other valuable products in a steam dilution of approx. 800-870 C. In the ideal case, if polyolefins are used as feedstock, then the initial product which led to the polymers can be fully recycled. In this context a series of experiments was carried out in a laboratory-scale cracker plant. The purpose of this was to demonstrate the technical feasibility and the economic advantage of using recycling polyethylene or polypropylene as feedstock for steam cracker plants. (orig./SR) [Deutsch] Die Linde AG als einer der bedeutendsten Kontraktoren fuer den Bau von Ethylenanlagen, deren Herzstueck die Steamcrackeroefen sind, hat ...

1996-12-31

86

MRI of the pancreas: Radiological-pathological correlation; MRT des Pankreas: Radiologisch-pathologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

The typical MRI features of the most common pancreatic diseases, such as pancreatitis and adenocarcinoma of the pancreas, have been established. However, even in these common pancreatic disorders, MRI correlation with the underlying pathology is limited for clinical reasons. We emphasize MR-pathological correlation of inflammatory and neoplastic pancreatic changes, including pancreatitis, adenocarcinoma, acinar cell carcinoma, rare cystic and solid pancreatic neoplasms, and islet cell tumors. By highlighting the correlation of key pathological features with MR findings, a better understanding of the MR appearance of pancreatic pathology can be provided. In addition, MRI may prove a powerful tool in detection and characterization of pancreatic tumors. (orig.) [Deutsch] Das MR-tomographische Erscheinungsbild von Pankreatitiden und Adenokarzinomen des Pankreas, als den haeufigsten Pankreaserkrankungen, ist zwar ausreichend bekannt; allerdings ist selbst bei diesen ...

1996-05-01

87

Innovations in terms of material technology for steam turbines with high thermal efficiency; Werkstofftechnische Entwicklungen fuer Dampfturbinen mit hohem thermischen Wirkungsgrad  

Energy Technology Data Exchange (ETDEWEB)

Steam turbines of the new power plant generation enable the realisation of over-critical steam parameters with 600 C and 300 bar by means of simple and double resuperheating. Extensive research work in the field of material technology has provided the pre-conditions. Forged pieces, castings, high-temperature ferritic 9 - 10 % CrMoV steels, which are additionally alloyed with niobium, nitrogen and wolfram, are used in steam turbines. A proof of strength for shaft and cast steels is available by means of a long-term stress-rupture test of up to max. 60,000 hours. The strength of turbine steels exceeds the one in tube and header steels (x 10 CrMoVNbN 9 1). (orig./MM) [Deutsch] Dampfturbinen der neuen Kraftwerksgeneration erlauben heute die Realisierung von ueberkritischen Dampfparametern mit 600 C und 300 bar mit einfacher und zweifacher Zwischenueberhitzung. Umfangreiche werkstofftechnische Forschungsarbeiten haben dafuer die Voraussetzung geschaffen. Zur Anwendung ...

1997-12-31

88

Hydrogen-metal isotherms at low degrees of occupancy and at low pressures; Die Wasserstoff-Metall-Isotherme bei kleinen Beladungsgraden und kleinen Druecken  

Energy Technology Data Exchange (ETDEWEB)

Metal hydrode stores are used as fuel tanks in vehicles or as stationary stores of high-purity hydrogen. Equilibrium isotherms at low pessures were measured in order to validate the laws of Henry or Sievert for hydrogen uptake of the alloy Ti{sub 0.98}Zr{sub 0.02}V{sub 0.43}Fe{sub 0.09}Cr{sub 0.05}Mn{sub 1.5} (patented by Daimler Benz AG, code DB5800). The laws were to provide information on whether hydrogen uptake is atomic or molecular and on the conditions in which isothermal measurements are possible. (orig.) [Deutsch] Metallhydridspeicher werden als Kraftstofftank in Fahrzeuge oder als stationaere Speicher zur Bereitstellung von Reinstwasserstoff verwendet. Fuer diese Arbeit wurden die Gleichgewichtsisothermen bei kleinen Druecken vermessen, um die Gesetze von HENRY oder SIEVERT fuer die Wasserstoffaufnahme in der Legierung Ti{sub 0.98}Zr{sub 0.02}V{sub 0.43}Fe{sub 0.09}Cr{sub 0.05}Mn{sub 1.5} zu pruefen. Anhand dieser Gesetze ist zu ...

1997-11-01

89

Humidity impact on the thermal insulation in case of higher insulation levels; Feuchteeinfluesse auf den praktischen Waermeschutz bei erhoehtem Daemmniveau  

Energy Technology Data Exchange (ETDEWEB)

The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase in insulating layer thickness in order to improve the thermal insulation is possible without humidity problems; - today`s ...

1994-12-31

90

Experience with the OBD II functions from use in mass production, prospect for the further development of the diagnosis functions foe US applications; Erfahrungen mit den OBDII-Funktionen aus dem Serieneinsatz, Ausblick auf die Weiterentwicklung der Diagnosefunktionen fuer US-Anwendungen  

Energy Technology Data Exchange (ETDEWEB)

The required introduction of on board diagnosis II in the USA from the 94 models onward has led vehicle manufacturers and system suppliers to develop corresponding diagnosis processes at the beginning of the 1990`s. These systems are now in mass production for TLEV and partly for LEV requirements. Based on experience from the wide use of these functions, new knowledge has been obtained, which must be taken into account in the development of future systems. The additionally more severe emission and diagnosis requirements make further minimisation of the overall tolerances on the one hand, and a revision of the existing diagnosis algorithms necessary. In parallel with this, the Law must create the necessary outline conditions, where the requirements for the vehicle manufacturer and system suppliers must also be met. The OBD II development must therefore certainly not be regarded as complete. [Deutsch] Die in den USA ab Modelljahr `94 geforderte Einfuehrung der On Board Diagnose II hat zu ...

1997-12-31

91

Effects of ductile particles on the toughness and deformation characteristics of NiAl matrix materials; Einfluss duktiler Teilchen auf die Zaehigkeit und das Verformungsverhalten von NiAl-Matrix-Werkstoffen  

Energy Technology Data Exchange (ETDEWEB)

The intermetallic phase NiAl is a potential material for high-temperature applications; however, its technical application was prevented so far by its high brittleness at room temperature. This problem may be solved by incorporating relatively high-ductility particles into the NiAl matrix. Controlled crack propagation experiments, tensile and pressure tests were carried out in order to analyze the toughness and deformation characteristics of NiAl composite materials containing niobium or molybdenum particles at room temperature and in ambient atmosphere. Both the niobium and the molybdenum particles increase the toughness as compared to the pure NiAl matrix, but no ductilisation was observed in the composite materials investigated. Model experiments in consideration of experimental data suggest, hovewer, that the toughness and ductility of NiAl may be enhanced by optimizing the microstructural and production parameters of the incorporated ductile particles. (orig.) [Deutsch] Die ...

1995-12-31

92

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, ...

2003-07-01

93

Specifications for dumping of residues from mechanical-biological waste treament facilities; Anforderungen an die Ablagerung von MBA-Abfaellen  

Energy Technology Data Exchange (ETDEWEB)

For purposes of assessing the dumpability of wastes, Article 1 - Ordinance on the Environmentally Responsible Landfilling of Household Wastes (AbfAblV) - of the Ordinance on the Environmentally Responsible Landfilling of Household Wastes and Biological Waste Treatment Plants defines classificaton criteria for biologically and mechanically treated wastes destined for landfilling. The practical experiences that have been gathered with these classification criteria and values were evaluated in a questionnaire-based survey. This was done in particular for the purpose of verifying and validating proposals on the methodology of respiration and fermentation tests. A general finding has been that the application and implementation of the regulations of the AbfAblV is fraught with difficulties. This is evident for one thing in the frequency of analyses and for another in the difficulty of complying with the limit values of the classification criteria. The authors are in support of demands that ...

2001-07-01

94

Microbial remediation of soil pollution from ore mining. Part 3: Cyanide removal and biosorption of heavy metals in mining and processing water; Untersuchungen zur mikrobiellen Sicherung von Erzbergbaualtlasten. Teilvorhaben 3: Cyanidabbau und Biosorption von Schwermetallen in Abwaessern aus Erzbergbau- und Aufbereitungsbetrieben. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

1. Cyanide degradation: Of the cyanide- and thiocyanate-degrading bacteria, Burkholderia cepacia and Pseudomonas spec. were the most effective. 2. Biosorption: Of the isolates suited for biosorption of heavy metals, 597-A (non-identifiable) and 597-A2 (Aspergillus fumigatis) had the biggest potential. The sorption capacity of the fungi for metals varied with the C source used for their growth: apple juice > molasses > glucose. The fungi are not cyanide-sensitive and can even degrade cyanide. Living biomass had better metal sorption efficiencies than dead mycelium. The biosorption rates in waste water were usually higher than in broth. Depending on the metal composition and concentrations and on the exposure time and volume of the mycelia, up to 85 % of the initial concentration was removed from the liquid phase. The capacity of different biomasses for the sorption of metal mixtures was between 65 and 80 mg/g of dry matter depending on the experimental conditions, with ...

1999-12-01

95

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI scanners suited for ...

1998-03-01

96

Degradation of toluene in a multistage bioreactor unit; Abbau von Toluol in einer zweistufigen Tropfkoerperbioreaktor-(TBR-)Anlage  

Energy Technology Data Exchange (ETDEWEB)

Volatile organic compounds (VOC) are an important group of pollutants with adverse effects on humans and the environment. Primary air pollution abatement measures aim at prevention or reduction of pollutant production in industrial production processes, e.g. by improved processes but also by other methods (closed cycle processes, different process materials, etc.). If these measures have been implemented and emissions are still too high, an off-air purification unit must be installed. Biological purification is the method of choice for low pollutant concentrations. Biological purification processes are based on the activity of microorganisms which are capable of biochemical oxidation of organic and some inorganic gaseous compounds into non-polluting or non-odorous compounds. These processes have the advantage that they work at ambient conditions and therefore remove relatively low pollutant concentrations at low investment and operating cost. Lately, biological filters and washers have ...

1997-05-01

97

TEM-investigations of the effect of iron content on the precipitation behaviour of NiMo28 type alloys; TEM-Untersuchungen zum Einfluss des Eisengehaltes auf das Ausscheidungsverhalten von Legierungen des Typs NiMo28  

Energy Technology Data Exchange (ETDEWEB)

Normally, the alloy NiMo28 is used in the solution annealed and quenched condition in which it has a face centred cubic matrix structure. The matrix of the material is supersaturated with molybdenum and, at temperatures above 800 C, has a tendency to form intermetallic precipitates such as the Ni{sub 4}Mo-ordered phase leading to the embrittlement of the NiMo28-ordered phase leading to the embrittlement of the NiMo28 alloy during hot working. For this reason, the aim of these investigations was to optimise the alloy by reducing its tendency to embrittle. The TEM-analyses carried out served to investigate the precipitation of the material as a function of its iron content after ageing at 700 C. The change in hardness and in the lattice constants of the NiMo28-specimens with iron content were also determined. To improve the hot working properties of this material it is recommended that the iron content be kept to about 3.2 mass % in order to reduce the tendency of the alloy to ...

1996-07-01

98

Quantitative CT assessment of proximal femoral bone density. An experimental study concerning its correlation to breaking load for femoral neck fractures; Quantitative CT des proximalen Femurs. Experimentelle Untersuchungen zur Korrelation mit der Bruchlast bei Schenkelhalsfrakturen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In an experimental study, the correlation between the trabecular bone density of the different regions of the proximal femur and the fracture load in the setting of femoral neck fractures was examined. Methods: The bone mineral density 41 random proximal human femora was estimated by single-energy quanitative CT (SE-QCT). The trabecular bone density was measured at the greatest possible extracortical volume at midcapital, midneck and intertrochanteric level and in the 1 cm{sup 3} volumes of the centres of these regions in a standardised 10 mm thick slice in the middle of the femoral neck axis (in mg/ml Ca-hydroxyl apatite). The proximal femora were then isolated and mounted on a compression/bending device under two-legged stand conditions and loaded up to the point when a femoral neck fracture occurred. Results: Statistical analysis revealed a linear correlation between the trabecular bone density and the fracture load for the greater regions, with the highest value in the ...

1997-12-01

99

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters; Digitale Vergroesserungsmammographie mit Speicher-Folien-Technik. Standardisierte und befundorientierte Bildverarbeitungsparameter  

Energy Technology Data Exchange (ETDEWEB)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage phosphor screen ...

1997-05-01

100

A retrospective comparison of endoscopic stenting alone with stenting and radiotherapy in non-resectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Radiotherapy has been reported to be of benefit in prolonging the survival of patients with cholangiocarcinoma. This study examined whether radiotherapy in addition to endoscopic stenting improved survival. The survival advantage of radiotherapy in those with a type II/III stricture is seen only in the first 10 months after diagnosis. The costs of radiotherapy and significantly increased time spent in hospital, however, raise doubts over its routine use in the management of non-resectable cholangiocarcinoma. (Author).

101

Environmentally friendly individual mobility through the `Zoxy` zinc/air battery system for electric road vehicles; Umweltschonende individuelle Mobilitaet durch das ``Zoxy``-Zink-Luft-Batteriesystem fuer elektrische Strassenfahrzeuge  

Energy Technology Data Exchange (ETDEWEB)

To permit an assessment of the system presented in this paper the data collected up to this point should be complemented by further experience with its practical use in electromobiles and the recovery of zink and the electrolyte. To this end the system is to be tested in electromobiles in 1995 and 1996. If there are no serious problems in the course of these tests and the above-mentioned estimates on economic efficiency are confirmed, then there is much to be said for a large-scale trial of these battery systems in electromobiles in the framework of a pilot project in Karlsruhe. Because of the infrastructure required for recharging, such a project should first be carried out in cooperation with fleet operators. As the recharging technique employed is so simple as to require no great investment and cost-effectiveness should already be achievable with a few tens of vehicles, one can conceive of a whole variety of applications in cooperation with public utilities, municipalities, and ...

1995-12-31

102

Correlation between the microstructure and the physical properties of HTSC single crystals and films. Final report; Korrelation zwischen der Realstruktur und den physikalischen Eigenschaften von HTSL-Einkristallen und -Schichten. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

1. In order to carry out isothermic crystal growth experiments of YBCO the 123 primary crystallization field was determined by means of phase diagram investigations and crystal growth experiments at different oxygen partial pressure. 2. YBCO single crystals of high crystallographic perfection were grown and conclusions on the flux pinning mechanism were drawn. 3. By means of Liquid Phase Epitaxy (LPE) single crystalline (Tc{approx}90 K; {Delta}T{<=}0.5 K) c- and a,b- YBCO fils have been prepared on NdGaO{sub 3} and LaGaO{sub 3} substrates. The films were characterized structurally and magnetically. 4. Our fist melt textured YBCO ``single crystals`` possess intracrystalline critical current densities >10{sup 4} A/cm{sup 2} at B{<=}2T. The irreversibility inductions are {<=}6 T at 77 K. A simple demonstrator was constructed together with the IFW Dresden and a growth model was developed. 5. Using above all torque magnetometer measurements we separated intrinsic pinning effects ...

1993-06-01

103

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

104

Protons, heavy ions, radioactive beams: new ways for radiotherapy. Protons, ions lourds, faisceaux radioactifs: de nouvelles voies pour la radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the principles, applications and advantages of proton and heavy ion beams used for radiotherapy.

1993-07-01

105

Magnetic resonance imaging (MRI) of the central nervous system in long-term manganese dioxide (MnO{sub 2}) exposed workers; Magnetresonanztomographie des Gehirns bei Beschaeftigten mit chronischer beruflicher Mangandioxid-Exposition  

Energy Technology Data Exchange (ETDEWEB)

Aim: Changes within the brain detected by MRI after chronic manganese poisoning raised the question whether morphological changes of the basal ganglia, particularly of the globus pallidus, could be detected after chronic occupational exposure to manganese dioxide. Results: No cases of parkinsonism were detected in clinical examinations or by other means. The mean manganese concentration in blood was 12 {mu}g/l (range: 3.9-23.3 {mu}g/l). In comparison to the upper reference value of 10 {mu}g/l, 42 workers (56%) had a higher body burden. A significant positive correlation between manganese levels in blood and the PI (indicated by T{sub 1}-shortening) was observed as well as between the CBI and workplace-specific exposure. Brain atrophy was not detected in any of the observed cases. Conclusions: Long-term exposure to manganese dioxide dust correlates with the Pallidum-Index in MRI scans. Although the MRI findings have no current clinical relevance for individuals, further studies are ...

2000-06-01

106

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an in-plane resolution of ...

1996-03-01

107

Fractionated stereotactic radiotherapy in the treatment of pituitary macroadenomas  

UK PubMed Central (United Kingdom)

BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available

2008-12-01

108

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

109

Adaptive Radiation for Lung Cancer  

UK PubMed Central (United Kingdom)

The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such...Full Text Available

2011-01-01

110

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

111

High-efficiency, thin-film- and concentrator solar cells from GaAs. Final report; High-efficiency, Duennschicht- und Konzentrator-Solarzellen aus Galliumarsenid. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Main topic of the project was the manufacturing of highly efficient GaAs-solar cells and the fabrication of concentrator cells. During this process significant progress was made with the material preparation, the solar cell technology and the material and process characterisation. This succeeded in the following efficiencies: - GaAs solar cell made by MOVPE technology: 22.9% on 4 cm{sup 2} (AM1.5g) - GaAs solar cell made by LPE-ER process: 22.8% on 4 cm{sup 2} (AM1.5g) - GaAs concentrator solar cell made by LPE-ER process: 24.9% at C=100xAM1.5d - GaAs concentrator module with fresnel lenses: Module efficiency 20.1% (under irradiation of 793 W/m{sup 2}). Another main focus was the epitaxy of GaAs on Si substrate. Two different approaches were investigated. Together with the cooperation partner ASE, Heilbronn a selective growth technology was developed that led to a decreased crack formation. By a simultanous optimization of the other epitaxy and process parameters, the efficiency was ...

1996-10-01

112

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row ...

2004-09-01

113

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being overestimated by MRI in 4 ...

1999-03-01

114

Effect of co- and counter-swirl on the isothermal flow- and mixture field of a double-airflow burner; Einfluss gleich- und gegensinniger Verdrallung auf das isotherme Stroemungs- und Mischungsfeld eines luftseitig zweiflutigen Brenners  

Energy Technology Data Exchange (ETDEWEB)

Atomization of liquid fuel in aircraft engines requires application of airblast atomizers, where the kerosene is supplied into the shear layer between two swirling airstreams. The transfer of this functional principle towards gaseous fuel, as illustrated in Fig. 1, yielded a strong influence of the swirl arrangement of the airflows on flame stability and homogeneity of the fuel/air-mixture. Compared to the co-swirl configuration the flow field of the counter-swirl arrangement exhibits a marked increase of the mass flow recirculated in the internal recirculation zone and a reduction of its length in axial direction. This is attributed to the faster decay of tangential velocity maxima in case of counter-rotating airflows. This generates a stronger positive axial pressure gradient dp/dx, thus enhancing the internal recirculation zone. Analysis of local turbulence quantities yields a restriction of turbulent exchange to smaller radial sections and lower maximum values in the jet dominated ...

2002-11-01

115

Development of a thermographic measurement process as an alternative to gravimetry in determining Diesel engine particle emission. Final report; Entwicklung eines thermographischen Messverfahrens als Alternative zur Gravimetrie bei der Ermittlung von Dieselpartikel-Emissionen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Against the background of more severe limitation of particle emission in all application areas of Diesel engines, it is necessary to monitor the particle emission, but also the chemical composition of the particles. The basis of assessing particle emission is formed by gravimetric determination of the particle concentration from exhaust gas diluted with particle-free ambient air, with a maximum temperature of 52 degrees C at the sampling position. While it is already possible, using the part flow dilution system, to take samples locally, previously the subsequent particle determination and characterisation could only be done in a chemical laboratory. For this reason, the C/S particle measurement process was developed as an alternative to gravimetry, which can be used locally, eg: on ships and which makes it possible to determine the particle mass and composition. This process is based on a thermographic carbon and sulphate determination. Comparative investigations were done both on ...

1994-12-31

116

Experimental, non-isothermal modelling of combustion for verification of mathematical, theoretical methods. Final report; Experimentelle, nichtisotherme Modellierung der Verbrennung zur Verifizierung von mathematischen, theoretischen Verfahren. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

In technical combustors, flow and combustion processes inside the combustion chamber determine the design and also the safety of the plant. A modelling technique was developed at TU Dresden which comprises both numerical simulations and experimental data and thus achieves a high degree of transparency in its visualisation of the processes inside the combustion chambers under investigation. With the experience gained, numerical models of commercial simulation software (FLUENT, CFX) can be validated by measured values, and potential applications of the programs can be investigated. The first stage of experimental modelling consisted in isothermal (cold) modelling in consideration of flow-relevant similarity characteristics. In the reactive, non-isothermal models, the fuel/air ratio and temperature conditions inside the original combustion chamber were modelled as well. In order to obtain detailed data on the combustion conditions at the burner, measurements were made on a separate ...

1998-05-26

117

Aircraft Research Guideline 1999 - 2002: High pressure compressor - preliminary design as a basis for the development of an efficient and environmentally friendly core engine. Final report; Leitlinie Luftfahrtforschung 1999 - 2002: Hochdruckverdichter-Vorauslegung als Grundlagenuntersuchung zur Entwicklung eines Kerntriebwerkes fuer einen effizienten und umweltfreundlichen Antrieb. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

This report completes the documentation for the research project 'High Pressure Compressor - Preliminary Design as Basis for the Development of an Efficient and Environmentally Friendly Core Engine' which was funded by the Ministry of Economics of State Brandenburg. The objective of the project is to deliver a preliminary compressor aerodynamic design as well as design studies for an efficient, weight and cost improved compressor. The increase of stage pressure ratio and improved efficiency, whilst stage and blade count is reduced, has been achieved by advanced 3D methods. Compressor stability also at off-design conditions will be retained. The mechanical design focusses on a cost and weight optimised rotor not only for a conventional bladed discs but also for Blish stages. Various options for split casings have been developed and assessed. Alternative vortex reducers based on different design options have been carried out. The results from this project will be ...

2001-08-01

118

Quality controls in radiotherapy. From experiences of the first course-debate  

International Nuclear Information System (INIS)

The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure.

1998-12-03

122

Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system  

UK PubMed Central (United Kingdom)

The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available

2009-01-01

125

Supervision of construction, quality assurance, operating experience in the new heating power station II; Bauueberwachung, Qualitaetssicherung, Betriebserfahrungen mit dem neuen Heizkraftwerk II  

Energy Technology Data Exchange (ETDEWEB)

After 3 years of construction the trial run of the heating power station HKW 2 ended in November 1997 on time. No extraordinary damage occured during construction, assembly or commissioning. The plant has been operating according to schedule since November 1997. A brief inspection carried out in the summer of 1998 in order to assess warranty claims showed no damage to any part except one valve. Experience shows that all aforementioned activities were necessary. The paper reports about success and negative experience. Certification according to DIN EN ISO 9000ff., however, affords to guarantee of high-quality construction. Builders of such plants therefore need to set up their own quality assurance centre and ensure its technical competence. If necessary,additional experts should be called in.Quality assurance costs for HKW 2 came to about 0.5-0.6 percent of total costs. In view of the success and long life of this investment these expenses are more than justified. (orig.) [German] Nach ...

1998-07-01

126

Condition Monitoring in Power Stations; Condition Monitoring im Kraftwerk  

Energy Technology Data Exchange (ETDEWEB)

Maintenance of power stations so far operated on the concept of using or extending the expected service life of a machine or plant as far as possible in order to avoid early and costly replacement. This was done by means of time-oriented maintenance, inspection and repair, otherwise called preventive maintenance. A European study on maintenance methods totals the cost of these measures at between 140 to 200 billion DM. One way of reducing these costs is 'predictive maintenance'. Estimated savings are about 8 percent or between 12 and 16 billion DM per year. Predictive maintenance identifies irregulaties of machine parts at an early point in time by means of condition monitoring and can help to cut costs: unplanned repairs can be avoided; repairs can be fitted into production schedules; production will not be disturbed to to unforeseen repairs, optimised spare part warehousing helps to cut costs. Predictive maintenance aims at keeping availability high, give maximum ...

1998-07-01

127

MRI of congenital heart disease in childhood; MR-Tomographie kongenitaler Herzvitien im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before MRI to guide the planning of the examination. With a systematic segmental approach ...

2004-02-01

128

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed tomography (SPECT) ...

2003-12-01

131

Weld metal as strong as base metal?; Schweisszusatzwerkstoffe koennen/muessen nicht immer die Anforderungen der Grundwerkstoffe erfuellen  

Energy Technology Data Exchange (ETDEWEB)

The development of new steels is always a challenge for the manufacturer of filler metals. In many cases it is obvious that some properties of the base metal cannot be fulfilled with matching filler metals. In some cases, dissimilar filler metals can solve the problem in some cases, there is no chance to meet the requirements of the base metal (for example yield strengths of new ultra high strength steels). This paper deals with different kinds of new steels and the requirements for the weld metal with examples from motor car industry (Mangan Austenite), crane (Ultra high strength steels), earthmoving machinery (Wear-resistant steels) and offshore (Supermartensitic steels). Specific problems will be discussed and best solutions will be highlighted. These examples make clear that the success of new kinds of steels in the market depends on solving the joining problems of these steels. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] Die Entwicklung von neuen Staehlen ist ...

2007-07-15

132

Towards an overhauling of the international nuclear liability regime - the revision of the Vienna Convention; Auf dem Wege zur Erneuerung der internationalen Atomhaftungssysteme - die Revision des Wiener Uebereinkommens  

Energy Technology Data Exchange (ETDEWEB)

The paper addresses the major items of relevance to compensation for nuclear damage under civil liability law. The revision of the Vienna Convention deserves support as a contribution to enhancing the protection of those who suffered damage, and of the environment. The results of the revision will have an impact on the liability regimes in existing and future signatory states, and to some extent will also set the goals of a future reshaping of the Paris Convention, all the more since the Joint Protocol calls for harmonization of at least basic provisions of substantive law in the two Conventions. (orig./HP) [Deutsch] Es werden die wesentlichen Punkte dargestellt, die fuer die zivilrechtliche Praxis im Schadensfall von Belang sein koennten. Die Revision ist als Beitrag zu einem verbesserten Schutz Geschaedigter, aber auch der Umwelt zu begruessen und zu unterstuetzen. Die Ergebnisse werden sich auf die Rechtsordnungen der gegenwaertigen und zukuenftigen Vertragsstaaten auswirken und ...

1995-12-31

133

The specific heat consumption and the loss mechanisms at the nozzle-group regulation of steam turbines; Zum spezifischen Waermeverbrauch und den Verlustmechanismen bei der Duesengruppenregelung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue Verfahren zur wahlweisen Zuschaltung unterschiedlicher ...

1995-07-01

134

Sanitation of the River Lahn concerning organic loads from waste water. Pt. 2. The impact of effluents from waste water treatment plants; Sanierung der Abwasserbelastung eines Fliessgewaessers am Beispiel der Lahn. T. 2. Klaeranlagenemissionen  

Energy Technology Data Exchange (ETDEWEB)

In a case study of the River Lahn, Hessen, Germany, the ecological impact of effluents from sewage treatment plants was investigated. These emissions have a significant impact on the receiving water quality with ammonia, nitrite, phosphorus and the eutrophication as most important factors. Current legislation standards seem to be sufficent for the sanitation of the nitrogen load. The potential of phosphorus removal in sewage treatment plants however may not reach the demand for eutrophication abatement. Therefore, integrated and immission oriented strategies are required including in site measures of river restoration. (orig.) [Deutsch] An der hessischen Lahn wurde in einem mehrjaehrigen Forschungsvorhabens die Bedeutung von Abwasserereinleitungen aus Klaeranlagen hinsichtlich ihrer gewaesseroekologischen Relevanz untersucht. Wesentliche Belastungen beziehen sich auf die Parameter Ammonium, Nitrit und Phosphor sowie eutrophierungsbedingte Folgeerscheinungen. Waehrend ...

1995-12-01

135

Rational imaging strategies in larynx disease; Rationelle bildgebende Strategien bei Kehlkopferkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische Information unabdingbar: Wenn neurologische Veraenderungen im Bereich ...

1998-02-01

136

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of the X-ray field and the beam direction of X-rays. Optimal ...

2009-05-15

137

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last 30 ...

2010-06-15

138

Multi-rotor-stations, a new concept for large-scale wind power stations; Multi-Rotor-Konstruktionen. Ein neues Konzept fuer grosse Windkraftanlagen  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to the usual way of installing wind machines in extended windfarms new concepts are being developed. Several wind turbines are affixed to one support structure and can be aligned together. Drafts of steel constructions developed by students in three diploma theses are presented. The attempt to transform existing design standards requires extensive discussion of possible influence scenarios. Several concepts regarding structure and safety elements are described and evaluated. The design of the support structure is to be seen as a first step to the practicability of the whole concept. A preliminary mass calculation and a specification of further cost factors facilitates the comparison to conventional wind power stations. (orig.) [Deutsch] Als Alternative zur ueblichen Praxis, Windenergieanlagen in Form grossflaechiger Windparks zu bauen, werden Konzepte entwickelt, bei denen mehrere Konverter an einem Tragwerk angeordnet und ...

1996-06-01

139

Monitoring of a passive house school building; Erkenntnisse ueber Lueftung und Energieverbrauch sowie Bodenplattendaemmung aus Monitoring-Untersuchungen an einem Passivhaus-Schulgebaeude  

Energy Technology Data Exchange (ETDEWEB)

More than two and a half years of monitoring of a passive house school and day-care centre in Frankfurt a. M. show comfortable indoor climate and good air quality. The space heat consumption is low and shows savings of approximately 90 % as compared to average existing schools. Excellent performance was also achieved in terms of primary energy. The results of further analyses of the efficient ventilation system with heat recovery, the perimeter insulation as an alternative to floor slab insulation and the influence of the air change due to the entrance door are presented. (Abstract Copyright [2008], Wiley Periodicals, Inc.) [German] Ueber zweieinhalb Jahre Monitoring einer Passivhaus-Schule und Kindertagesstaette (KiTa) in Frankfurt a.M. zeigt behagliche raumklimatische Bedingungen bei guten Luftqualitaeten. Die Heizwaermeverbrauchswerte liegen wie erwartet niedrig und zeigen Einsparungen um 90 % gegenueber dem Durchschnitt im Bestand. Auch primaerenergetisch ...

2008-02-15

140

Monitoring and evaluation of policy instruments to support renewable electricity in EU Member States. Summary; Monitoring und Bewertung der Foerderinstrumente fuer Erneuerbare Energien in EU Mitgliedsstaaten. Kurzfassung  

Energy Technology Data Exchange (ETDEWEB)

Policy strategies for the promotion of electricity from renewable energy sources differ significantly among the Member States of the European Union with respect to the amount of additional installed capacity as well as concerning the country-specific support costs. The present report aims to assess the effectiveness and the economic efficiency of the support policies in the EU based on both historical experiences and prospective model-based analysis. The main message of the investigation is that the most effective policy instruments tend to be cost-efficient at the same time. In particular, feed-in tariff systems were identified as a successful instrument for supporting renewable energies in terms of effectiveness and efficiency, whereas quota systems still have to prove themselves in practice. (orig.) [German] Bezueglich des Erfolges bei der Foerderung erneuerbarer Energietraeger im Stromsektor bestehen deutliche Unterschiede zwischen den Mitgliedsstaaten der ...

2006-09-15

141

LEED - The green building rating system; Gruen ist nicht gleich Gruen - Einblicke in das LEED-Zertifizierungssystem  

Energy Technology Data Exchange (ETDEWEB)

Buildings in the USA are commonly not perceived as energy efficient and sustainable. Considering this, it comes as a surprise that the LEED (Leadership in Energy and Environmental Design) certification system is leading the process to certify ''Green Buildings'' despite the broad range of certification systems in countries such as BREEAM in England, CASBEE in Japan, HQE in France, Green Star in Australia, and most recently DGNB in Germany. International companies are pursuing the LEED certification due to its worldwide applicability - over 20,000 buildings in 76 countries are currently registered. (Abstract Copyright [2009], Wiley Periodicals, Inc.) [German] Die USA sind nicht gerade fuer oekologisches und energieeffizientes Bauen bekannt. Umso erstaunlicher ist es, dass das LEED-Zertifizierungssystem (Leadership in Energy and Environmental Design) neben anderen landesspezifischen Systemen wie z. B. BREEAM in England, CASBEE in Japan, HQE in ...

2009-04-15

142

Effect of stratified water injection on exhaust gases and fuel consumption of a direct injection diesel engine; Einfluss der geschichteten Wassereinspritzung auf das Abgas- und Verbrauchsverhalten eines Dieselmotors mit Direkteinspritzung  

Energy Technology Data Exchange (ETDEWEB)

The direct injection Diesel engine with its specific fuel consumption of about 200 g/kWh is one of the most efficient thermal engines. However in case of relatively low CH- und CO-emission the soot- and NO{sub x} concentration in the exhaust gas turns out to be a problem with respect to the legislation on emission limits. At the department of piston- and turbo-machines of the Trier University of Applied Sciences, a single-cylinder testing engine with two injection-systems (fuel and water) has been developed. This engine has been constructed to analyse the effect of stratified water-injection on the soot- and NO{sub x} emissions of exhaust gases of a Diesel engine. (orig.) [German] Der Dieselmotor mit Direkteinspritzung stellt mit spezifischen Kraftstoffverbraeuchen in der Groessenordnung von 200 g/kWh eine der wirtschaftlichsten thermischen Kraftmaschinen dar. Bei relativ niedrigen Kohlenwasserstoff- und Kohlenmonoxid-Emissionen erweist sich die Russ- und ...

2004-01-01

143

Crack propagation measurements with eddy current probes at specimens under cyclic thermal stress; Rissverlaengerungsmessungen an thermozyklisch belasteten Proben mittels Wirbelstromsonden  

Energy Technology Data Exchange (ETDEWEB)

Experiments for lifetime prediction of the first wall are being carried out within the framework of the European fusion reactor programme. Defects such as notches and cavities may develop in the first wall and may initiate under cyclic thermal stress cracking processes which may reduce the service life of the material. For examination of crack growth, specimens with defined initial notches were prepared and subjected to cyclic thermal loads. The paper shows that the eddy current method is suitable for detecting and revealing the crack growth processes even under conditions of complex geometry, as e.g. cracks in inner bores. The experiments indicated particularly susceptible, critical spots in the first wall and yielded crack growth rates of use for lifetime calculations. (orig./CB) [Deutsch] Im Rahmen des europaeischen Fusionsreaktorprogramms werden Untersuchungen zur Lebensdauervorhersage der Ersten-Wand durchgefuehrt. Die Erste-Wand kann Fehler in Form von ...

1997-12-31

144

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that experience and the knowledge of associated artifacts and the limitations they can impose on diagnosis are prime requirements for the implementation of such visualization techniques. (orig.) [German] Die ...

2008-02-15

146

Ewing's sarcoma family tumors of the humerus: Outcome of patients treated with radiotherapy, surgery or surgery and adjuvant radiotherapy  

International Nuclear Information System (INIS)

Background and purpose: Local treatment for non-metastatic Ewing's sarcoma family tumors (ESFTs) is controversial. Results achieved in a single institution in patients with ESFT of the humerus are presented. Materials and methods: Patients treated between 1983 and 2000 for ESFT of the humerus were included. The impact of local treatment (surgery, radiotherapy or both) on outcome was assessed. Results: 55 patients: 34 males (62%); 21 females (38%); mean age: 17.9 (range: 3-40). Local treatment: surgery in 27 patients (49%), radiotherapy in 17 (31%) and surgery followed by radiotherapy in 11 (20%). After a mean follow-up of 15 years (range: 7-25 years), 27 patients (49%) remained continuously disease free, 27 (49%) relapsed and one died of chemotherapy toxicity. The local recurrence rate was 13% overall: 18% (3/17) after radiotherapy, 7% (2/27) after surgery and 19% (2/11) after surgery followed by ...

2009-11-01

147

Investigation of dominant loss mechanisms in low-temperature polymer electrolyte membrane fuel cells  

Energy Technology Data Exchange (ETDEWEB)

This thesis deals with the analysis of dominant loss mechanisms in direct methanol fuel cells (DMFC) and hydrogen fed polymer electrolyte membrane fuel cells (PEFC) by means of experimental characterization and modeling work. Due to different fuels used in these two fuel cell types, the dominant loss mechanisms are different in their nature. All in-situ characterization techniques that are used in this work are based on a novel test fuel cell with embedded reference electrodes. The first part of this work presents a new concept for realizing a reference electrode configuration in a polymer electrolyte membrane fuel cell by means of laser ablation. The laser beam is used to evaporate a small gap into the electrode surface of a catalyst coated membrane (CCM) to isolate the reference electrode from the working/counter electrode (WE/CE). This method enables the simultaneous ablation of the electrodes on both sides of the CCM because the membrane is transparent for the laser beam. ...

2010-07-01

148

Radiotherapy in the management of Kaposi's sarcoma: comparison of 8 Gy versus 6 Gy.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate prospectively the efficacy of a single fraction of high-dose radiotherapy in patients with Kaposi's sarcoma. PATIENTS: Between 1994 and 2004, 47 patients with Kaposi's sarcoma...Full Text Available

2006-07-01

149

Radiation Therapy and Psychological Distress in Gynecologic Oncology Patients: Outcomes and Recommendations for Enhancing Adjustment  

UK PubMed Central (United Kingdom)

SummaryRadiotherapy is used commonly in the treatment of gynecologic malignancies. Many patients experience emotional distress prior to the initiation of radiotherapy, during...Full Text Available

1986-01-01

150

Objective assessment of deformable image registration in radiotherapy: A multi-institution study  

UK PubMed Central (United Kingdom)

The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area...Full Text Available

2008-12-01

151

Intensity modulated radiotherapy: advantages, limitations and future developments  

UK PubMed Central (United Kingdom)

Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available

152

Early and late skin reactions to radiotherapy for breast cancer and their correlation with radiation-induced DNA damage in lymphocytes  

UK PubMed Central (United Kingdom)

IntroductionRadiotherapy outcomes might be further improved by a greater understanding of the individual variations in normal tissue reactions that determine tolerance. Most published...Full Text Available

2005-01-01

153

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

154

A Hybrid Strategy of Offline Adaptive Planning and Online Image Guidance for Prostate Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

The offline adaptive radiotherapy (ART) has been used to effectively correct and compensate the prostate motion and reduce the required margin. The efficacy depends on the characteristics of...Full Text Available

2010-04-21

155

Multidisciplinary management of Ewing's sarcoma : a pragmatic approach  

International Nuclear Information System (INIS)

Treatment of Ewing's sarcoma by radiotherapy, chemotherapy and surgery singly and in combination is reviewed.(M.G.B.).

156

Institute of Toxicology. 1994 annual report on research and development; Institut fuer Toxikologie. Ergebnisbericht ueber Forschung und Entwicklung 1994  

Energy Technology Data Exchange (ETDEWEB)

The R and D activities of the institute focused on two major projects, ``Molecular and cellular environmental toxicology``, and ``Biophysics of multi-cellular systems``. For assessment of health risks emanating from the uptake of heavy metal compounds, work performed under the first mentioned project studies the formation of allergy-inducing metabolic products from membrane lipids, and the effects of related cellular signaling processes. These studies are accompanied by an approach to quantify and classify the toxicity of environmental organometallic compounds. Another major task is research into the pathogenesis of lung disease induced by dusts, gases, and gas-dust mixtures and the liberation of inflammatory agents by immunological cell reactions (alveolar macrophages). Atomic force microscopy is the tool used to visualize the related dynamic changes in bronchial cells. Studies for detection of the localisation and structure of the Fe-Mo co-factor in nitrogenase by means of the method ...

1995-12-31

157

Feasibility study for new ecolabels for the product group: Wood pellet firings. Final report; Machbarkeitsstudie fuer neue Umweltzeichen fuer die Produktgruppe: Holzpelletfeuerungen. Endbericht  

Energy Technology Data Exchange (ETDEWEB)

This assessment is a feasibility study according to ISO 14024. It deals with the question whether an ecolabel is suitable for wood pellet heating systems and how concrete criteria for an ecolabel for wood pellet heating plants could be specified. The study begins with a comprehensive market analysis in order to identify possible plants for which an ecolabel would make sense. In the main part of the study, the environmental relevance of the chosen plants is analysed. For this analysis, plant manufacturers were interviewed and a comparison between wood pellet heating systems and heating systems which use gas, oil or wood was carried out. On the basis of this analysis, it was possible to derive a number of criteria which were discussed with company representatives and other experts in this field. As a result of this dialogue and the investigation process as a whole, the introduction of an ecolabel for wood pellet heating plants can be recommended. Wood pellet heating systems are ...

2002-07-01

158

Development of process technology for large-area thin-film solar modules based on compound semiconductors. Final report; Entwicklung der technologischen Grundlagen fuer grosse Photovoltaikmodule auf Basis von Duennschicht-Verbindungshalbleitern. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

A cooperative effort of the Center for Solar Energy and Hydrogen Research (ZSW) and Phototronics Solartechnik GmbH (PST) aimed at the transfer of highly efficient solar cells developed on a laboratory scale, to large-area thin-film solar modules suitable for production. This work was based on research and development at the Institute for Physical Electronics (IPE) of Stuttgart University and ZSW on one hand, and on the know-how of PST in regard to large-area module fabrication on the other hand. The various thin-film layers of the cells and modules comprize molybdenum as rear contact, copper-indium(gallium)-diselenide (CIGS) as absorber material, the combination of cadmium sulphide (CdS) and ZnO as window layer. To produce these layers on large areas (30x30 cm{sup 2}), equipment was constructed and procedures were developed. Monolithic series connection of cells, used in other thin-film technologies, was studied and optimized by suitable patterning procedures, such as laser-scribing, ...

1998-06-01

159

Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers; Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels mit der MRT: Reproduzierbarkeit am Probanden  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial plateau and 3.5% ({+-}2.0%) in the lateral tibial plateau. The ...

1997-12-01

160

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical diagnostic ...

1995-12-31

161

High-dose radiation therapy for inoperable non-small cell lung cancer without mediastinal involvement (clinical stage N0, N1)  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of radiation therapy alternative to surgery for clinical N0-N1 non-small cell lung cancer (NSCLC). From 1976 through 1989, 116 patients with NSCLC without mediastinal involvement were treated with definitive radiation therapy alone at Gunma University Hospital. All patients were treated with once-daily standard fractionation using 10 MV X-rays. The total dose ranged from 60 Gy to 80 Gy. The actuarial 2- and 5-year survival rates of the entire group were 43% and 20%, respectively with a median survival time of 19 months. The survival of 76 patients with stage T2 tumors was significantly better than that of 28 patients with T3 tumors (mean survival time 21 versus 15.5 months; p<0.05). Sixty-two patients with tumors less than 5 cm in diameter had a 2-year progression rate of 20%, in comparison with 39% of 54 patients with tumors greater than 5 cm. The difference of survivals for these 2 groups was statistically significant. Twelve patients given a total dose ...

1996-09-01

162

Characterization of decarburisation processes during austenitising of the rolling bearing steel 100Cr6. Part 2: Modelling of the carbon concentration profile by means of the finite element method; Charakterisierung von Randentkohlungsvorgaengen bei der Austenitisierung des Waelzlagerstahls 100Cr6. Teil 2: Modellierung des Kohlenstoff-Tiefenverlaufs mit Hilfe der Methode der Finiten Elemente  

Energy Technology Data Exchange (ETDEWEB)

The quantitative measurement of carbon concentration-distance curves serves as fundamental prerequisite for the evaluation of rim zone properties connected with decarburisation processes in material science. This was shown in part 1 of the present work with two samples from through-hardenable rolling bearing steel 100Cr6 (SAE 52100) austenitised in different oxidising atmospheres by position dependent determination of hardness, residual stresses, and X-ray line broadening ({l_brace}211{r_brace} {alpha}'-Fe diffraction line). In practice, it is important to predict carbon concentration-distance curves under prevailing heat treatment conditions or to conclude conversely from profile measurements. Based on a refined kinetics model of a diffusion-controlled process, part 2 therefore presents a simulation tool developed by means of the finite element method (FEM). Apart from the concentration dependence of the diffusion coefficient, it also considers the decarburisation induced ...

2003-08-01

165

Treatment of peripheral aneurysms by dacron-covered nitinol stents; Behandlung arterieller Aneurysmen der Becken-Bein-Gefaesse mittels Dacron-ummantelter Nitinol-Stents  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to surgery. There are ...

1998-03-01

166

Thermal-catalytic cracking, a new process for complete decomposition of organic pollutants. Report on application 06/56/96 (feasibility study); Thermisch-katalytische Spaltung als neuartiges Verfahren zum vollstaendigen Abbau organischer Schadstoffe. Bericht zum Angebot Nr. 06/56/96 (Machbarkeitsstudie)  

Energy Technology Data Exchange (ETDEWEB)

This feasibility study of the uve Institut fuer Technische Chemie und Umweltschutz GmbH discusses the scientific and technical fundamentals of a catalytic process for complete removal of organic pollutants (PAH, H-HC, PCB, phenols, nitro-aromatics and organometallic compounds, e.g. from polluted soil and groundwater) by thermal-catalytic cracking and conversion into simple gases. The process is based on the catalytic reaction of the hydrocarbon compounds with water vapour in the temperature range of 700-900 degrees centigrade. The resulting gas mixtures consist mainly of hydrogen, carbon monoxide, carbon dioxide and methane which can be used as fuels, e.g. for heating or in gas engines. The process is an alterntive to combustion. It is therefore well suited whenever the pollutant to be removed is already mixed with water or water vapour and wherever in-situ removal would be too great a hazard. [Deutsch] Die vorliegende Machbarkeitsstudie aus dem uve Institut fuer Technische Chemie und ...

1998-05-01

167

Modified nickel based standard brazing filler metals for units under corrosive loads; Modifizierte Nickelbasisstandardlote fuer korrosiv belastete Bauteile  

Energy Technology Data Exchange (ETDEWEB)

Nickel-based alloys are presently used as brazing filler metals for components which undergo mechanical stress in corrosive conditions, f. e. heat exchangers. When soldering chrome containing steel parts with nickel based brazing filler metals additionally containing boron and silicon a reaction of chrome and boron can occur. This evolution of chromium borides, depositing on grain boundaries, causes a lack of chrome in the steel part. A drop of the chrome content in the parts below 13 % leads to a loss of corrosion resistance. It is possible to change the microstructure of brazing joints by modification with chromium and molybdenum. Continuous brittle phases could be successfully avoided with this modification. Furthermore it could be shown that the choice of additives, the heating respectively cooling rate and the brazing temperature have important influence on the microstructure evolution and therefore on the mechanical and corrosive properties of joints. (Abstract Copyright [2008], ...

2008-01-15

168

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the innovations presented here, applied alone or in combination, facilitate rapid, robust, and ...

2004-12-01

169

Investigations on the braking safety of utility vehicles with retarders; Untersuchungen zur Bremssicherheit von Nutzfahrzeugen mit Retardern  

Energy Technology Data Exchange (ETDEWEB)

When the use of retarders in utility vehicles increased in the middle of the 80s, the Forschungsvereinigung Automobiltechnik (FAT) commissioned a study on the safety aspect of this braking technology in trucks. Retarders are wear-free permanent brakes that are fitted in the drive transmission system of utility vehicles, thereby generating braking forces only at the wheels of the live shaft. The question of the possible overbraking of the live shafts was just as well investigated as the interaction between the retarder and service brake in so-called integrated braking systems, and both under conditions of low adhesion as well as in the border area of the dynamics of vehicle movement. This subject met with considerable joint interest on the part of the motor vehicle industry as well as of manufacturers of towed vehicles and unit sets. FAT, therefore, commissioned the Institut fuer Kraftfahrwesen of the University of Hannover to carry out a three-phase research project on the braking ...

1996-12-31

170

Energy passport, public funding programme, marketing campaign. Effects of selected communal air pollution abatement measures in Hanover city; Energiepass, Foerderprogramm, Marketingkampagne. Die Wirksamkeit ausgewaehlter kommunaler Klimaschutzmassnahmen in Hannover  

Energy Technology Data Exchange (ETDEWEB)

Already in 1998, the city of Hanover, the Stadtwerke Hannover and six further cities of the region initiated the funding programme 'Hannover proKlim' for promoting energy-relevant modernization measures in domestic buildings. One year later, the social marketing campaign 'Haus-Partner Hannover / Der (H)Eissbaer'' was started, which addresses building owners in Hanover with the intention to induce them to action. The 'Energiepass Hannover' is another important instrument of the campaign. This report takes stock of the results achieved so far. [German] Beim Klimaschutz im Gebaeudebestand lassen sich in Hannover drei Ansaetze hervorheben, die parallel zueinander entwickelt wurden und die in besonderer Weise dazu beitragen, die CO{sub 2}-Emissionen im Gebaeudebestand zu reduzieren: Bereits 1998 hat die Landeshauptstadt Hannover gemeinsam mit den Stadtwerken Hannover und sechs weiteren Staedten der Region den Klimaschutz-Fonds ...

2001-07-01

171

Diagnosis and therapy of Budd-Chiari syndrome; Diagnostik und Therapie des Budd-Chiari-Syndroms  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no complications were encountered. ...

1998-09-01

172

Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging; Flussquantifizierung in Koronar- und Bypassgefaessen mit der MR-Phasenkontrasttechnik  

Energy Technology Data Exchange (ETDEWEB)

Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass ...

2000-02-01

176

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...

2009-06-15

177

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

178

Biopsy examination during the course of radiotherapy. Progress report. [DNA content of tumor cells in biopsy samples determined by microfluorometric or multiangle light-scatter spectrometry  

Science.gov (United States)

Studies begun during the first year of this project on biopsies from spontaneous tumors in dogs and from human patients undergoing radiotherapy treatment were continued. The results indicate that significant fractions of the spontaneous tumors in dogs and cervical carcinomas in patients undergoing radiotherapy have a DNA content higher than normal diploid cells. The higher DNA content in tumor cells permits distinguishing them from normal cells in the biopsy material with the aid of flow microfluorometric (FMF) instrumentation or multiangle light-scatter spectrometry.

1977-12-01

179

Similar Treatment Outcomes for Radical Cystectomy and Radical Radiotherapy in Invasive Bladder Cancer Treated at a United Kingdom Specialist Treatment Center  

International Nuclear Information System (INIS)

Purpose: To conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer. Patients and Methods: Between March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data. Results: There was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences in the radiotherapy group (24 solitary), but there was no significant difference in distant recurrence-free ...

2008-02-01

180

Similar Treatment Outcomes for Radical Cystectomy and Radical Radiotherapy in Invasive Bladder Cancer Treated at a United Kingdom Specialist Treatment Center  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer.Patients and MethodsBetween March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data.ResultsThere was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences...

2008-01-01

181

Radiotherapy for nonfunctioning pituitary adenomas: from conventional to modern stereotactic radiation techniques  

British Library Electronic Table of Contents (United Kingdom)

The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...

2007-01-01

182

Orbital lymphoma: Role of radiation  

UK PubMed Central (United Kingdom)

The purpose of this article is to review the literature for clinical presentation, treatment, outcome and complications of using radiotherapy for the treatment of orbital lymphoma. For this, MEDLINE,...Full Text Available

2009-03-01

183

Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

2005-01-01

184

Green Tea Extract (Epigallocatechin-3-Gallate) Reduces Efficacy of Radiotherapy on Prostate Cancer Cells  

British Library Electronic Table of Contents (United Kingdom)

ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...

2011-01-01

185

Constitution of a centralised data base for the internal quality control in radiotherapy; Constitution d'une base de donnees centralisee pour le controle de qualite interne en radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)

2009-10-15

186

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

187

Adaptive Management of Liver Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available

2010-04-01

188

Quantitative analysis of spinal CSF dynamics using magnetic resonance imaging: experimental and clinical studies; MR-tomographische Liquorflussmessungen am Spinalkanal mit einem optimierten MRT-Protokoll: experimentelle und klinische Untersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Measurement of the oscillating CSF flow in the spinal canal (SC) of healthy volunteers and in patients with post-traumatic syringomyelia (PTS) using an optimized MRI protocol as well as to determine whether stenosis induced velocity changes are detectable using MRI. Methods: In 68 healthy volunteers quantitative studies of CSF flow in the cervical, thoracic, and lumbar regions were performed. First, an optimized sequence was developed and tested in 19 volunteers using four different flow-encoding velocities (4, 8, 12, 16 cm/s). Secondly, the optimized sequence was employed in 49 volunteers to measure the different CSF patterns in the cervical, thoracic, and lumbar spinal canals (CSC, TSC, LSC). Part three of the study, in which patients with PTS are being examined is still underway. We measured the maximum velocity (cm/s), the pixel area (mm{sup 2}), and the stroke volume (ml/s). Using a flow model the velocities prior to and after compression with 5 different power levels ...

2001-04-01

190

Effect of Reynolds Number and Periodic Unsteady Wake Flow ...  

Science.gov (United States)

verse pressure gradient, makes it susceptible to flow separation, ...... AGARD, Lecture Series LS-167. [25] Eifler, J., 1975, Zur Frage der freien ...

191

MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography; MR-Tomographie in der morphologischen Darstellung der isolierten non-compaction des linksventrikulaeren Myokards (NCVM)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T{sub 1}-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was measured for non-compacted and compacted myocardium and ...

2003-09-01

192

Carbomolybdates(III): On Pr{sub 2}[Mo{sub 2}C{sub 3}] and structural relations to Er{sub 2}Mo{sub 2}C{sub 3}; Carbomolybdate(III): Zur Kenntnis von Pr{sub 2}[Mo{sub 2}C{sub 3}] sowie Strukturbeziehungen zu Er{sub 2}Mo{sub 2}C{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

Pr{sub 2}[Mo{sub 2}C{sub 3}] was obtained by arc melting of the elements followed by annealing at 1500 C in arc welded and sealed Mo-ampoules. The compound was characterised by chemical analyses, X-ray diffraction and metallography. The crystal structure (monoclinic, P2{sub 1}/c, Z = 4, a = 597.99(10) pm, b = 665.15(11) pm, c = 1185.60(19) pm and {beta} = 111.631(5) ) represents a new structure type containing a three dimensional polyanion {sub {infinity}}{sup 3}[(Mo{sub 2}C{sub 3}){sup 6-}] with Molybdenum(III) in a distorted tetrahedral coordination by carbo-ligands. Tetrameric building-blocks, Mo{sub 4}C{sub 10}, of edge sharing MoC{sub 4}-tetrahedra are arranged to form layers running parallel to (100). The layers are interconnected along [100] by sharing common apices of the MoC{sub 4} tetrahedra. The coordination polyhedra around praseodymium represent distorted (PrC{sub 5})-arrangements (mono capped tetrahedra and square pyramids). The metal atoms together form a distorted motif ...

2004-11-01

193

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas were observed and follow up CT one day and 4 weeks after the radiofrequency ...

2001-11-01

194

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...

1999-05-01

195

MRI of liposarcomas. Observations on 28 liposarcomas; Magnetresonanztomographie der Liposarkome. Beobachtungen an 28 Liposarkomen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. Only scattered fatty islands and septa (9 patients with myxoid ...

1996-08-01

196

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee; Die MRT beim Haemarthros des Kniegelenks: Bestimmung von Blutungsursachen, Verletzungsmustern und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of the cases. Single, combined and bland lesions were accurately ...

1996-09-01

197

Heat management through intelligent components in the cooling system; Waermemanagement durch intelligente Komponenten im Kuehlkreislauf  

Energy Technology Data Exchange (ETDEWEB)

The further optimisation and improvement of the efficiency of internal combustion engines require the realisation of new technologies leading to a distinctively faster warm-up behaviour of the coolant and lubricants as well as of the engine components after a cold start. In order to achieve reduced fuel consumption and exhaust gas emissions with the help of heat management, the design criteria of innovative cooling systems need to be reflected and adapted to future requirements. The use of intelligent components within the cooling system, such as the 'Stand Alone Rotary Valve' as a thermostat's substitute or the use of coolant pumps with a rotary valve integrated into the pump's inlet chamber, offer new ways to realise in a decisively quicker and more flexible way the appropriate heating up and cooling down procedures at varying driving conditions. A description of both of the intelligent components for the cooling system is given in this paper. The ...

2001-07-01

198

Differential diagnosis of rheumatic diseases; Differenzialdiagnose rheumatischer Erkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic Arthritis or simply but not always simple ...

2006-05-15

199

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...

2004-09-01

200

The value of radiotherapy in the treatment of Ewing's sarcoma in children  

International Nuclear Information System (INIS)

Results of treatment of 30 children with Ewing's sarcoma irradiated in the First Radiotherapy Department, Cancer Center, Warsaw, in the period 1983-1992, are described. In 40% of patients NED survival from 1 till 10 years and in 70% the local control was obtained, and no serious radiations equelae were observed. (author).

201

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

202

Radiotherapy quality assurance review in a multi-center randomized trial of limited-disease small cell lung cancer: the Japan Clinical Oncology Group (JCOG) trial 0202  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of this study was to analyze the radiotherapy (RT) quality assurance (QA) assessment in Japan Clinical Oncology Group (JCOG) 0202, which was the first trial...Full Text Available

203

INL Advanced Radiotherapy Research Program Annual Report 2004  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.

2005-06-01

204

INEEL Advanced Radiotherapy Research Program Annual Report for 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-01

205

INEEL Advanced Radiotherapy Research Program Annual Report 2002  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.

2003-05-23

206

Evaluation on the clinical effect of lysozyme chloride in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Lysozyme chloride was administered to 84 patients of laryngeal cancer and the clinical effect was discussed. Lysozyme chloride delayed the appearance of swelling and white plaque while it accelerated that of inflammatory erythema in radiotherapy. No difference of the local inflammation was found between lysozyme administered groups and not administered groups when irradiation and chemotherapy were combined. Any side effect was not seen in blood picture of all cases by using lysozyme chloride.

1982-10-01

207

Endocavitary radiotherapy of rectal tumours; Endokavitaer straalebehandling ved distale rectum tumorers  

Energy Technology Data Exchange (ETDEWEB)

The authors describe their experience of endocavitary radiotherapy of adenomas and carcinomas of the lower rectum. The method is an alternative for patients who cannot undergo standard surgical procedure or do no want a permanent colostomy. This method is cheap, fast and causes little discomfort to the patients, gives reasonable long-term results and has low morbidity. 11 refs., 4 figs., 2 tabs.

1997-02-01

208

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

213

Karl Urlichs Translation of "Durch Spaltstroemungen hervorgerufene ...  

Science.gov (United States)

Dampfturbinen bei hohen Dampfparametern [Study of shaft seals for steam turbines under high steam parameters],. Maschinenbautechnik L5, 27-31 (1966)0 ...

214

Physical aspects of quality assurance in radiotherapy: A protocol for quality control  

International Nuclear Information System (INIS)

In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a ...

2009-06-21

215

Ewing's sarcoma: a combined approach in the management  

International Nuclear Information System (INIS)

Twenty-seven histologically confirmed cases of localised Ewing's sarcoma were treated by two different regimes. Radiotherapy alone was used in 13 cases and a combination of chemotherapy and radiotherapy in 14. Single agent chemotherapy (cyclophosphamide) was given sequentially in nine patients and cyclophosphamide and actinomycin-D in five. There is a significant difference in the response to these different regimes. Only 69.2% of patients treated by radiotherapy alone were disease-free, for a median period of 10.4 months and metastases were noticed in 53.8% of cases. The disease-free survival in patients treated by combination therapy (radiotherapy and chemotherapy) was 18.4 months and metastases were seen in only 42.9%. However, no metastases were seen in patients who received cyclophosphamide and actinomycin-D, during a period of 14 months and only one patient showed residual disease. It is concluded ...

216

Radiotherapy versus surgery in good-risk Ewing's sarcoma. An analysis of the CESS 86-data  

International Nuclear Information System (INIS)

The evaluation of radiotherapy and surgery as exclusive local treatment in comparably selected subgroups of patients with Ewing's sarcoma on the basis of the CESS 86-data. In the German multicenter Ewing's sarcoma study CESS 86, treatment consisted for four 9-week-courses of VACA- or VAIA-chemotherapy plus local therapy. VACA (vincristine, actinomycin D, cyclophosphamide, adriamycin) was given in low-risk extremity tumors with a tumor volume below 100 cm"3. Highrisk patients with central lesions or a tumor volume >100 m"3 received VAIA (ifosfamide instead of cyclophosphamide). Local therapy started after one complete chemotherapy course in week 10. Based on an individual decision in each patient, local therapy was either radical surgery or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy. Because of poor results with radiotherapy in a preceeding study, it was intended to restrict ...

217

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France; Ameliorer la qualite et la securite de la radiotherapie: un objectif conjoint de l'A.S.N. et de l'Agence regionale de l'hospitalisation Ile de France. Reflexions sur une cooperation feconde en Ile de France  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...

2009-02-15

218

Radiation therapy in Ewing's sarcoma: an update of the CESS 86 trial  

International Nuclear Information System (INIS)

Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and ...

1995-07-15

219

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...

2009-01-01

220

Funding programme ``30 low energy buildings in Hesse`` - experience and conclusion; Foerderprogramm `30 Niedrigenergiehaeuser in Hessen` - Erfahrungen und Schlussfolgerungen  

Energy Technology Data Exchange (ETDEWEB)

Low energy buildings promise significant energy savings and help climate preservation by cutting down on annual heating requirements to values below 70 kWh per m{sup 2} dwelling space. It is expected that low energy constructions will become the common standard by the year 2000 as a result of the forthcoming energy saving ordinance. For making the introduction and implementation of this standard successful, practical experience will be essential. For this reason, the state government of Hesse has supported respective pilot projects 1987. In 1989 the funding programme `30 low energy buildings in Hesse` has been established. Consecutively - between 1989 and 1993 - 29 buildings were erected. At first, the thermal quality of the crafted building construction including the ventilation systems was checked. Consecutively, energy consumption, indoor and outdoor temperatures were measured over a time span of several years. The experience of the inhabitants was surveyed. The `Institut Wohnen und ...

1998-10-01

222

Scalp Angiosarcoma Remission with Bevacizumab and Radiotherapy without Surgery: A Case Report and Review of the Literature  

UK PubMed Central (United Kingdom)

Angiosarcoma (AS) is a rare and aggressive vascular neoplasm with very poor prognosis. Patients with extensive cutaneous AS who are not surgical candidates have very limited options since there is no...Full Text Available

2011-01-01

223

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

224

Range and modulation dependencies for proton beam dose per monitor unit calculations  

UK PubMed Central (United Kingdom)

Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available

2009-02-01

225

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

226

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

227

Quality controls in radiotherapy. From experiences of the first course-debate; Controlli di qualita' in radioterapia. Dalle esperienze del primo corso-dibattito  

Energy Technology Data Exchange (ETDEWEB)

The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure. [Italian] Questo documento e' dedicato al primo corso-dibattito sui controlli di qualita' in radioterapia svoltosi a Roma il 3-4 dicembre 1998 e il 3-5 maggio 1999 in collaborazione tra l'Istituto Superiore di Sanita' e l'Istituto Regina Elena. Esso presenta gli argomenti ritenuti critici per l'assicurazione di qualita' in radioterapia in relazione all'intera procedura radioterapica, in base alle esperienze dei partecipanti.

2000-07-01

228

Prevention and treatment of functional and structural radiation injury in the rat heart by pentoxifylline and alpha-tocopherol  

UK PubMed Central (United Kingdom)

PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available

2008-09-01

229

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

230

PLESIOTHERAPY FOR NON-MELANOMA SKIN CANCER: INNOVATING TO OVERCOME!  

UK PubMed Central (United Kingdom)

Background:The non-surgical management of non-melanoma skin cancers is an area requiring clinical investigation. Radiotherapy has a role in treatment for a defined subset...Full Text Available

2010-10-01

231

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

232

Metastatic tumor of thoracic and lumbar spine: prospective study comparing the surgery and radiotherapy vs external immobilization with radiotherapy; Metastases do segmento toracico e lombar da coluna vertebral: estudo prospectivo comparativo entre o tratamento cirurgico e radioterapico com a imobilizacao externa e radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Bone metastases at the thoracic and lumbar segment of the spine are usually presented with painful sensation and medullar compression. The treatment is based on the clinical and neurological conditions of the patient and the degree of tumor invasion. In the present study, 32 patients with spinal metastasis of thoracic and lumbar segment were prospectively analyzed. These patients were treated by decompression and internal stabilization followed by radiotherapy or irradiation with external immobilization. The election of the groups was in accordance with the tumor radiotherapy sensitivity, clinical conditions, spinal stability, medullar or nerve compression and patient's decision. The Frankel scale and pain visual test were applied at the moment of diagnosis and after 1 and 6 months. The surgical group had better results with preserving the ambulation longer and significant reduction of pain.(author)

2007-09-15

233

Estimation of cancer risks from radiotherapy of benign diseases  

Energy Technology Data Exchange (ETDEWEB)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-15

234

Estimation of cancer risks from radiotherapy of benign diseases  

International Nuclear Information System (INIS)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-01

235

Development of a Novel Post-processing Treatment Planning Platform for 4D Radiotherapy  

UK PubMed Central (United Kingdom)

The aim of this study is to develop an Automatic Post-processing Tool for four-dimensional (4D) treatment planning (APT4D) that enables the user to perform some necessary procedures related...Full Text Available

2008-04-01

236

Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available

237

Combined chemotherapy and radiotherapy of localized and metastasizing Ewing's sarcoma  

International Nuclear Information System (INIS)

Between 1973 and 1978 combined radiotherapy and chemotherapy were given to 22 patients with histologically proven Ewing's sarcoma. The combined chemotherapy consisted of cyclophosphamide, vincristin, adriamycin, as well as dacarbazine in some cases. The neoplasm was a localized one at the beginning of treatment in 14 of the 22. These patients received high-voltage rediotherapy to the primary focus at a focal dose between 42 and 55 Gray (4200-5500 rad), followed by chemotherapy. After 6-8 treatment cycles, adriamycin was replaced by methotrexate. Nine of the 14 patients survived without recurrence for 12 to over 59 months. Eight patients had extensive metastases at the beginning of treatment: they at first received only chemotherapy, followed by radiotherapy or operation, as indicated. Full clinical remission was achieved in five of them: in three this remission has now lasted for more than 18, 40 and 44 months, respectively. These results ...

238

Challenge and Hope in Radiotherapy of Hepatocellular Carcinoma  

UK PubMed Central (United Kingdom)

Hepatocellular carcinoma (HCC) is one of the most critical global health issues. With frequent association of viral liver disease, HCC is highly complex, harboring both cancer and chronic liver disease....Full Text Available

2009-10-31

239

An optimization method for reference dose point of rectum in brachytherapy of gynecological neoplasms  

International Nuclear Information System (INIS)

Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose ...

2002-05-01

240

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting ...

2001-09-01

241

Accelerated hyperfractionation (AHF) compared to conventional fractionation (CF) in the postoperative radiotherapy of locally advanced head and neck cancer: influence of proliferation  

UK PubMed Central (United Kingdom)

Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available

2002-02-12

242

A viral vaccine encoding PSA induces antigen spreading to a common set of self proteins in prostate cancer patients  

UK PubMed Central (United Kingdom)

PurposeWe previously reported a randomized phase II clinical trial combining a poxvirus-based vaccine encoding PSA with radiotherapy in patients with localized prostate...Full Text Available

2010-08-01

243

A systematic review to investigate the effectiveness and acceptability of interventions for moist desquamation in radiotherapy patients  

Energy Technology Data Exchange (ETDEWEB)

Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice ...

2009-08-15

244

Therapy of children with Ewing's sarcoma  

International Nuclear Information System (INIS)

Combined treatment of 131 patients aged 3-16 with local form of Ewing's sarcoma is carried out. Survival rate per year was studied in patients without diagnosed metastases depending on chemiotherapy method. It is stated that improved results of treatment of children with Ewing's sarcoma may be achieved by combining radiotherapy with long-term systemic polychemotherapy. The most efficient and expedient method of radiotherapy of long bone sarcoma in children is dialy three-field irradiation with 2 Gy at SFD to the tumor 60 Gy, and adjacent tissues - 40 Gy.

245

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

246

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

247

A dose computation algorithm used in MLC conformal treatment  

International Nuclear Information System (INIS)

A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)

2007-12-01

248

Improving radiotherapy quality and safety: a common objective of A.S.N. and the Ile de France Regional Hospital Agency. Thoughts on successful cooperation in Ile de France  

International Nuclear Information System (INIS)

Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...

2009-02-01

249

Obligations under international law for reducing transfrontier air pollution in Europe. Voelkerrechtliche Pflichten zur Verminderung grenzueberschreitender Luftverschmutzung in Europa  

Energy Technology Data Exchange (ETDEWEB)

The obligations under international law to reduce transfrontier air pollution is discussed in five chapters from various aspects. Consequences for the European Communities are gone into in five further chapters. (orig./HP)

1993-01-01

250

Cost reduced inspection concept of PE/XLPE medium voltage cables; Kostensparende Zustandsanalyse an PE-/VPE-isolierten Mittelspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten Mittelspannungskabels leisten. Basis der Alterungsdiagnose und des Konzeptes ...

1997-12-15

251

Conditioning of plastic wastes for thermal utilization; Aufbereitung von Kunststoffabfaellen zur thermischen Verwertung  

Energy Technology Data Exchange (ETDEWEB)

This article describes the processes for the treatment of plastic waste: sampling, sorting, comminution. The requirements for the different processes for waste treatment (as recycling, utilization as raw material, energy recovery, combustion) are listed. (SR)

1996-12-31

252

Computer codes for the determination of air flow in buildings; Rechenprogramme zur Bestimmung der Luftstroemungen in Gebaeuden  

Energy Technology Data Exchange (ETDEWEB)

The report provides and overview of calculation models for the simulation of airflows and deals comprehensively with field and multi-zone models as well as the coupling of individual zone and multi-zone models. Examples of calculations are given. figs., tabs., refs.

1994-12-31

253

Application of biosorption and accumulation processes for metal separation and recovery from polluted industrial effluents for the purpose of environmental pollution abatement. Final report; Nutzung von Prozessen der Biosorption und Akkumulation zur Metallabtrennung und Rueckgewinnung aus belasteten Abwaessern mit dem Ziel der Umweltsanierung; Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Fundamental investigations into the biosorption of environmentally relevant heavy metals were carried out with different microbial adsorbents, and processes were proposed for industrial effluents. In order to improve the technology of biosorption processes, attempts were made to improve the sorption efficiency of biological sorbents, and investigations were carried out on the immobilisation of biological adsorbents. (orig.) [Deutsch] Es wurden Grundlagenuntersuchungen zur Biosorption von umweltrelevanten Schwermetallen mit verschiedenen mikrobiellen Adsorbentien durchgefuehrt und an technischen Abwaessern Technologievorschlaege erarbeitet. Zur Verbesserung der Technologie von Biosorptionsprozessen wurden Moeglichkeiten der Steigerung der Sorptionsleistung von Biosorbentien erarbeitet und Untersuchungen zur Immobilisierung der biologischen Adsorbentien durchgefuehrt. (orig.)

1991-12-31

254

A multidisciplinary study investigating radiotherapy in Ewing's sarcoma: end results of POG no. 8346  

International Nuclear Information System (INIS)

Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone radiation to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy, and the ...

1998-08-01

255

Risk of leukaemia following intravenous treatment with {sup 224}Ra - results of a long term follow-up study of ankylosing spondylitis patients; Leukaemierisiko nach intravenoeser {sup 224}Ra-Behandlung - Ergebnisse einer Langzeitstudie an Bechterew-Patienten  

Energy Technology Data Exchange (ETDEWEB)

In an epidemiological study of the somatic late effects risk following incorporation of a short lived {alpha}-emitter, 1473 ankylosing spondylitis patients treated with repeated intravenous injections of {sup 224}Ra in the years 1948 - 75, have been observed in the GSF. The usual therapeutic plan consisted of a total of 10 - 12 injections of 1.036 MBq (28 {mu}Ci) of {sup 224}Ra each, given at weekly intervals; this would result in an cumulative {alpha}-dose of 0.56 - 0.67 Gy to the marrow-free skeleton of a 70-kg-man (standard man). These patients have been followed together with a control group of ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Until May 1993 (mean follow-up time 19.9 yr), 595 patients of the exposure group and 722 patients of the control group have died, causes of death have been ascertained for 578, resp. 668 patients. Among others we observed in the exposure group 10 cases of leukaemia (vs. 2.7 - 2.8 cases expected, p < 0.001) ...

1993-12-31

256

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to aligned rest is used as input to a ...

1999-10-01

257

Dynamic {sup 31}P-MR-spectroscopy of the quadriceps muscle. Influence of sex and age on spectroscopic results; Die dynamische 31-Phosphor-Magnetresonanz-Spektroskopie des M. quadriceps. Einfluss von Geschlecht und Alter auf spektroskopische Parameter  

Energy Technology Data Exchange (ETDEWEB)

Purpose: {sup 31}P-MRS is used to assess the influence of sex and age on quadriceps muscle metabolism before and after exercise. Materials and Methods: 32 healthy volunteers (15 women, 17 men; mean age: 38{+-}17 yrs.) were examined by dynamic phosphorus-31 ({sup 31}P) magnetic resonance spectroscopy (MRS). In the magnet, the quadriceps muscle was stressed by an isometric and an isotonic form of exercise until exhaustion, respectively. Results: Resting conditions: With increasing subjects` age, the ratio {beta}-adenosine triphosphate/total phosphate decreased (r=-0.37; p=0.02). With increasing subjects` age, the ratios inorganic phosphate/phosphocreatine (r=0.79; p=5x10{sup -8}), phosphomonoester/{beta}-adenosine triphosphate (r=0.74; p=10{sup -6}) and phosphodiester/{beta}-adenosine triphosphate (r=0.62; p=10{sup -4}) increased. The pH was the only one of the evaluated spectroscopic parameters which showed a sex-dependence: Female subjects had a significantly lower pH (7.03{+-}0.02) ...

1999-05-01

258

CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontine angle; CT und MRT tumoroeser Veraenderungen des Schlaefenbeins  

Energy Technology Data Exchange (ETDEWEB)

Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. Finally T1-weighted spinecho sequences in high ...

2003-03-01

259

Process for the chemical removal of ash from coal and device for carrying out this process. Verfahren zur chemischen Entfernung der Asche aus Kohle sowie Vorrichtungen zur Durchfuehrung dieses Verfahrens  

Energy Technology Data Exchange (ETDEWEB)

In order to remove ash from coal, it is introduced into an aqueous ash removal solution, which contains nitric acid or citric acid and ammonium hydrogen fluoride. The coal without ash is then separated from the aqueous solution. According to the process, either finely ground coal is introduced into the ash removel solution or the coal with the solution is ground in a wet pulveriser.

1981-03-13

260

TENSOMAX - a retrofit thermal stress monitoring system for steam turbines; TENSOMAX - Eine nachruestbare Ueberwachung der thermischen Beanspruchung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

TENSOMAX enables on-line monitoring of the thermal stress of the shaft to be performed in steam turbines, for which the TURBOMAX probe cannot be installed near the critical area of the shaft. TENSOMAX provides an alternative to the TURBOMAX with a slightly reduced accuracy of the simulation of the temperature distribution in the shaft. The high value placed on the operational performance of TENSOMAX remains, viz. that even with older turbines, and particularly in the case of turbines rehabilitated with a new shaft, careful and transparent operation is assured. (orig.) [German] Die Einrichtung TENSOMAX ermoeglicht eine Ueberwachung der thermischen Beanspruchung der Welle bei Dampfturbinen, bei denen die TURBOMAX-Sonde in der Turbine nahe der kritischen Stelle der Welle nicht einsetzbar ist. Daher stellt der TENSOMAX unter Beruecksichtigung minimaler Ungenauigkeit aufgrund der Nachbildung der Waermeuebergangszahl eine vorteilhafte Alternative zum ...

2000-07-01

261

Strengthening of the brazed joint for single-crystalline molybdenum by using Mo-40%Ru-B alloys  

Energy Technology Data Exchange (ETDEWEB)

In this study, the bend properties of the single-crystalline molybdenum brazed by using Mo-40%Ru alloys containing boron of 1-6 mass%Ru alloy for the improvement of the joint strength was determined. (orig.) [Deutsch] Durchgefuehrt wurde die Herstellung von Verbindungen aus einkristallinem Molybdaen. Hierbei kamen Mo-40%Ru-Legierungen mit 1 bis 6 Gew.-% Bor als Lotmaterialien zum Einsatz. Festigkeit und Duktilitaet der Verbindungen wurden mittels 3-Punkt-Biegepruefung bei Raumtemperatur und unter fluessigem Stickstoff ermittelt. Die Bruchflaechen der Proben wurden mit Hilfe eines Rasterelektronenmikroskopes untersucht. Die Ergebnisse lassen sich wie folgt zusammenfassen: Der optimale Borgehalt bezueglich Festigkeit und Duktilitaet der geloeteten Verbindung liegt bei 2 Gew.-%. Die entsprechende Probe hat bei einem Biegewinkel von 100 bei Raumtemperatur nicht versagt. Auch unter fluessigem Stickstoff ...

1998-12-01

262

Present state of development of electric cars with the example of the BMW E1. Derzeitiger Stand der Entwicklung bei Elektro-PKW am Beispiel des BMW E1  

Energy Technology Data Exchange (ETDEWEB)

The authors introduce the above electric car. They deal particularly with the vehicle concept, the energy consumption and the emission balance. (orig.).

1992-05-04

263

Immunoscintigraphy with anti-225.28S for ocular melanoma - a comparison with histology and immunohistochemistry  

Energy Technology Data Exchange (ETDEWEB)

Aim: The purpose of this prospective study was to evaluate the value of immunoscintigraphy (ISG) with anti-225.28S in clinically suspected ocular melanoma. Methods: For this purpose standardized ISG was performed in 36 patients using both planar acquisition and emission computed tomography (ECT). Ocular melanoma was present in 31 patients. In 21 patients therapy was enucleation of the eye. These specimens were evaluated by histology and immunohistochemistry in 11 of 21 patients. Results: Regarding the clinical diagnosis, ISG was positive only in 15 of 31 patients with ocular melanoma, regarding histology in 11 of 21 and regarding immunohistochemistry in 5 of 6 patients with a positive immunoreaction. 5 patients showed no immunoreactivity, their ISG was negative. Conclusion: Thus a good correlation between ISG and immunohistochemistry was observed. However ISG using the cutaneous melanoma antibody 225.28S cannot be recommended for the diagnostic work-up of an ocular melanoma considering ...

1997-03-01

264

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation doses (1-100 mGy) ...

2007-09-15

265

The role of surgical margins in treatment of Ewing's sarcoma family tumors: Experience of a single institution with 512 patients treated with adjuvant and neoadjuvant chemotherapy  

International Nuclear Information System (INIS)

Purpose: To evaluate the importance of surgical margins for local and systemic control of Ewing's sarcoma family tumors (ESFT). Methods and Materials: Between 1979 and 1999, 512 patients with ESFTs entered 4 different adjuvant and neoadjuvant studies performed at a single institution. Of these patients, 335 were treated with surgery alone (196) or surgery followed by radiotherapy at doses of 44.8 Gy (139). We compared their outcome with that of the 177 patients who were locally treated by radiotherapy at 60 Gy. Results: Local control (88.8% vs. 80.2%, p < 0.009) and 5-year disease-free survival (63.8% vs. 47.6%, p < 0.0007) were significantly better in patients treated with surgery and, among them, in those with adequate surgical margins (96.6% vs. 71,7%, p < 0.0008, and 69.6% vs. 46.3%, p < 0.0002). Nonetheless, better results were observed only in extremity tumors. Conclusions: Surgery is better than ...

2006-07-01

266

The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months ...

2009-12-01

267

Renal artery stenosis after radiotherapy for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been ...

2008-09-01

268

Radiotherapy in Ewing's sarcoma and PNET of the chest wall: results of the trials CESS 81, CESS 86 and EICESS 92  

International Nuclear Information System (INIS)

Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...

1998-12-01

269

A randomised controlled trial of intervention site radiotherapy in malignant pleural mesothelioma  

International Nuclear Information System (INIS)

Background and purpose: To assess the effectiveness of radiotherapy in preventing tumour seeding after chest drain or pleural biopsy in patients with malignant mesothelioma and to determine, if tract metastases appear, whether they are tender or troublesome to patients. Patients and methods: Patients with a histological diagnosis of pleural mesothelioma and an invasive procedure within the preceding 21 days were stratified by age, performance status and treatment centre. Randomisation was performed between immediate drain site radiotherapy 21 Gy in three fractions (XRT arm) or best supportive care (BSC) with follow-up to 12 months. Patients were asked to complete questionnaires on treatment toxicity and on symptoms from any tract metastases detected. Results: Sixty-one patients were recruited from two centres between 1998 and 2004; 56 men, 5 women, median age 70. 31 were allocated to drain site radiotherapy. Seven patients ...

2007-07-01

270

Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)  

Energy Technology Data Exchange (ETDEWEB)

The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...

1988-04-01

271

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...

272

Offshore wind power. Position paper of the Minister of the Environment; Windenergienutzung auf See. Positionspapier des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit zur Windenergienutzung im Offshore-Bereich  

Energy Technology Data Exchange (ETDEWEB)

The position paper will provide the basis for further strategies on offshore wind power development in consideration of ecological and conservation aspects. [German] Das Positionspapier des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit (BMU) einschliesslich des Umweltbundesamtes (UBA) und des Bundesamtes fuer Naturschutz (BfN) ist Ergebnis der Arbeiten der BMU-Projektgruppe 'Windenergienutzung im Offshore-Bereich im Hinblick auf die BMU-Anliegen'. Es beschreibt den derzeitigen Stand einer Strategie zur umwelt- und naturvertraeglichen Erschliessung der Windenergienutzung auf See (Offshore). Es bildet die Grundlage fuer die Weiterentwicklung dieser Strategie und dabei insbesondere zur Abstimmung mit den Anliegen anderer Bundesressorts und den Kuestenlaendern, sowie zur intensiveren Einbeziehung beteiligter Verbaende und Fachkreise. Vor dem Hintergrund der zur ...

2001-07-01

273

Woven polydioxanone biodegradable stents: a new treatment option for benign and malignant oesophageal strictures  

International Nuclear Information System (INIS)

We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. The BD stents need to be loaded into a conventional pull-back delivery system but are then placed in a standard fashion. Pre-dilatation should be avoided to reduce the risk of migration, however if migration occurs the stents can be left to dissolve in the stomach. The stents are radiolucent but easily identified on CT with minimal artefact and thus might even aid with radiotherapy planning. BD stents offer an exciting new strategy for therapy-resistant benign strictures as well as a supportive measure for oesophageal cancer undergoing non-surgical treatment. (orig.)

2010-05-01

274

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

275

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

276

Monte Carlo treatment planning for photon and electron beams  

British Library Electronic Table of Contents (United Kingdom)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...

2007-01-01

277

Local control of Ewing's sarcoma: an analysis of 67 patients  

International Nuclear Information System (INIS)

Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).

278

Fitness of equipment used for medical exposure to ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which ...

1992-05-01

279

Eosinophilia after radiotherapy for non-resected cervical cancer  

International Nuclear Information System (INIS)

The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).

1982-01-01

280

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive calls caused by enhancing ...

1997-09-01

281

Scientific and technical programme parallel to the 'Solarthermie 2000' research and demonstration programme. Final report; Wissenschaftlich-technische Programmbegleitung im Demonstrations- und Forschungsprogramm Solarthermie 2000. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The programme 'Solarthermie 2000' aimed at the testing and optimization of active solar systems, especially for service water heating. Sub-programme 2 was to provide the technical fundamentals and achieve a certain degree of standardization in order to make the technology economically competitive. This necessitated long-term monitoring of a representative number of systems. [German] Im Rahmen des Foerder- und Demonstrationsprogramms Solarthermie 2000, Teilprogramm 2 erfolgt durch die Foerderung von bis zu 100 solarthermischer Anlagen mit Schwerpunkt in den neuen Bundeslaendern eine umfassende Erprobung und Optimierung von Systemen zur aktiven thermischen Sonnenenergienutzung vorwiegend zur Brauchwassererwaermung. Mit dem Teilprogramm 2 sollen die technischen Voraussetzungen fuer einen kuenftigen wirksamen Beitrag der Solarthermie zur Energieversorgung geschaffen und durch Systemstandardisierung die ...

2000-07-01

282

Development of a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing; Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project was to develop a new technology for preparing samples for transmission electron microscopy (TEM) on the basis of ion fine beam processing. For this purpose processes of ion-beam-assisted removal (sputtering), separation, sample handling and ion-beam-assisted chemical etching as well of system-inherent components were examined. As an alternative to a Ga-source a liquid-metal ion source based on a AuGeSi alloy was developed, characterised and used in the FIB 4400. [German] Aufgabe des Projektes war die Entwicklung einer neuen Technologie zur Probenpraeparation fuer die Transmissions-Elektronenmikroskopie (TEM) auf der Basis der Ionenfeinstrahlbearbeitung. Dazu wurden Prozesse der ionenstrahlgestuetzten Abtragung (Sputtern), der Abscheidung, des Probenhandling, des ionenstrahlgestuetzten chemischen Aetzens sowie systemeigener Komponenten untersucht. Als Alternative zur Ga-Quelle wurde eine Fluessigmetall-Ionenquelle auf ...

2001-08-01

283

Hans-Christian Jacobaeus (1879?1937)  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Im Jahre 1910 f?hrte der schwedische Internist Hans-Christian Jacobaeus den ersten laparoskopischen Eingriff am Menschen in Stockholm durch. Grundlage seiner Pioniertat waren die tierexperimentellen Studien von Georg Kelling (1866?1945) aus Dresden, der im Jahre 1901 die erste Laparoskopie mittels eines Nitze-Zystoskops am Hund durchf?hrte. Jacobaeus ver?ffentlichte 1910 in der M?nchener Medizinischen Wochenschrift seine Erfahrungen mit den ersten 17 Laparoskopien unter dem Titel: ??ber die M?glichkeit die Zystoskopie bei Untersuchungen ser?ser H?hlen anzuwenden?. Hierbei nutzte er die neue Technik insbesondere zu diagnostischen Zwecken bei unklaren abdominellen Beschwerden und Funktionsst?rungen. Er war auch der Erste, der explizit auf die Gefahr der Darmverletzung bei Er?...

2006-01-01

284

Studies on biosorption and toxicity of heavy metals in bacteria; Untersuchungen zur Biosorption und zur Toxizitaet von Schwermetallen auf Bakterien  

Energy Technology Data Exchange (ETDEWEB)

Biosorption behaviour of and toxic effects of heavy metals in submersed and immobilised microorganisms was studied in batches and in continuous processes in an airlift-recycle reactor. Nickel, cadmium, and zinc were used as heavy metals. (orig./VHE) [Deutsch] Am Beispiel einer Naphthalin-2-sulfonsaeure-abbauenden Kultur wurde das Biosorptionsverhalten und die toxische Wirkung von Schwermetallen auf submerse und immobilisierte Mikroorganismen im Batch-Ansatz und im kontinuierlichen Betrieb in einem Airlift-Schlaufenreaktor untersucht. Als Schwermetalle wurden Nickel, Cadmium und Zink eingesetzt. (orig./VHE)

1993-09-01

285

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. Teil 2. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden Definitionen von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2001-07-01

286

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. T. 1. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2000-07-01

287

Process for the manufacture of a filter material for cleaning industrial or internal combustion engine exhaust gases and filter material manufactured according to the process. Verfahren zur Herstellung eines Filterstoffes zur Reinigung von industriellen oder Brennkraftmaschinen-Abgasen und ein hiernach hergestellter Filterstoff  

Energy Technology Data Exchange (ETDEWEB)

This is a process for the manufacture of a filter material for cleaning industrial or internal combustion engine exhaust gases and filter material manufactured according to the process. The filter material is manufactured from the mineralized combustion product of peel of tropical fruits burnt at a temperature of 820/sup 0/C to 840/sup 0/C in an oxidising atmosphere excluding the production of carbon, particularly using banana skins and orange peels, which product is granulated with carrier materials or compressed.

1986-01-02

288

Optimized short term power plant operation scheduling under consideration of load forecast errors; Kurzfristige Kraftwerkseinsatzoptimierung unter Beruecksichtigung von Lastprognosefehlern  

Energy Technology Data Exchange (ETDEWEB)

A programme to optimize the short-term operation planning of hydrothermal system scheduling is presented. Based on heuristics, an operational planning of pumped storage plants and a method for fast evaluations of spot market deals under consideration of load forecast errors was developed. (orig.) [German] Vorgestellt wird ein Programm, das - basierend auf Heuristiken - den kurzfristigen Einsatz eines hydrothermischen Kraftwerksparks optimiert. Im Programm wurde dazu ein Verfahren zur Pumpseichereinsatzplanung und zur sekundenschnellen Bewertung von Spot-Markt-Geschaeften unter Beruecksichtigung von Lastprognosefehlern entwickelt. (orig.)

2001-07-01

289

High aspirations; Hoch hinaus mit Energiebus-Technik  

Energy Technology Data Exchange (ETDEWEB)

In Duisburg the Citibank is building a new call center. As an alternative to the conventional switch cupboard technology, an innovative energy bus technology by ABB Gebaeudeautomation is being used: it involves less planning effort, faster start of operation and a shorter construction time, cost saving through lower space and material demand, plus the advantage of flexibility of extension. (orig.) [German] In Duisburg entsteht zur Zeit der Neubau eines Call Centers der Citibank. Dabei wird als Alternative zur herkoemmlichen Schaltschranktechnik die innovative Energiebus-Technik von ABB Gebaeudeautomation eingesetzt: Geringerer Planungsaufwand, schnellere Inbetriebnahme und kurze Bauzeit, Kostenersparnis durch geringeren Platz- und Materialverbrauch sowie flexible Erweiterbarkeit sind die Vorteile. (orig.)

1999-09-01

290

Handbook and comments concerning the Act of Housing Property (WEG) with notes on heating costs and the Ordinance on Heating Installations, relevant legislation and models for administering property and dealing with legal proceedings. WEG Handbuch und Kommentar zum Wohnungseigentumsgesetz mit Anmerkungen zur Heizkosten- und Heizungsanlagen-Verordnung, einschlaegigen Gesetzestexten und Mustern zur Begruendung und Verwaltung von Wohnungseigentum sowie zum gerichtlichen Verfahren  

Energy Technology Data Exchange (ETDEWEB)

This publication contains the Ordinance on Heating Costs, the Ordinance on Heating Installations, and the 1st Federal Ordinance on Emission Control (BImSchV) concerning Small-Scale Furnaces, in each case with notes and explanations. All these ordinances aim at reducing energy consumption in connection with heating; the 1st BImSchV also at air pollution abatement by lowering the permissible limiting values for soot and flue gas. The three ordinances also apply to housing property. (HSCH).

1991-01-01

291

Automatic phased array ultrasonic testing of pressure vessels; Automatisierte Mehrkanal Ultraschallpruefung von Druckgasbehaeltern  

Energy Technology Data Exchange (ETDEWEB)

Automatic ultrasonic testing is presented as a method for recurrent inspections of pressure gas vessels, from validation to practical testing to customised test applications. National and international regulations and standards are presented along with related implementation problems. [German] Es wird die automatisierte Ultraschallpruefung im Bereich der wiederkehrenden Pruefung von Druckgasbehaeltern, als Alternative zur herkoemmlichen, klassischen Wasserdruckpruefung, vorgestellt. Von der Validierung ueber die praktische Erprobung bis hin zur kundenspezifisch entwickelten Pruefapplikation. Es werden die Anforderungen aus nationalen und internationalen Vorschriften und Normen sowie die damit zusammenhaengenden Umsetzungsprobleme behandelt.

2005-07-01

292

Preoperative MR-guided localization of suspicious breast lesions; MR-gesteuerte praeoperative Drahtmarkierung unklarer Mammalaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the lesion was 7.6{+-}2.6 mm (range 3-14 mm). Conclusion: Suspicious breast lesions detectable only in MR imaging can be accurately localized with a hook wire preoperatively under MR control to ...

2000-09-01

293

MRI in postoperative assessment of univentricular heart disease: correlation with echocardiography and angiography; MRT in der postoperativen Diagnostik bei funktionell univentrikulaerem Herz: Korrelation zu Echokardiographie und Kardangiographie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 patients. The exact anatomy ...

2002-12-01

294

Use of absorbable mesh to displace bowel and avoid radiation enteropathy, during therapy of pelvic Ewing's sarcoma  

International Nuclear Information System (INIS)

The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).

295

Synergistic activity of the proteasome inhibitor PS-341 with non-myeloablative 153-Sm-EDTMP skeletally targeted radiotherapy in an orthotopic model of multiple myeloma  

UK PubMed Central (United Kingdom)

Multiple myeloma is a highly radiosensitive skeletal malignancy, but bone-seeking radionuclides have not yet found their place in disease management. We previously reported that the proteasome inhibitor...Full Text Available

2006-05-15

296

Radiotherapy and multimodality management of cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in multivariate analysis ...

1999-04-01

297

Quality assurance in radiotherapy: Proposal of guidelines concerning clinical and technological aspects; Assicurazione di qualita` in radioterapia: Proposta di linee guida in relazione agli aspetti clinici e tecnologici  

Energy Technology Data Exchange (ETDEWEB)

The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.

1996-12-01

298

NADPH oxidase-mediated reactive oxygen species production activates hypoxia-inducible factor-1 (HIF-1) via the ERK pathway after hyperthermia treatment  

UK PubMed Central (United Kingdom)

Hyperthermia (HT) is a strong adjuvant treatment with radiotherapy and chemotherapy because it causes tumor reoxygenation. However, the detailed molecular mechanisms of how HT enhances tumor oxygenation...Full Text Available

2010-11-23

299

Localization of 131I-labeled p97-specific Fab fragments in human melanoma as a basis for radiotherapy.  

UK PubMed Central (United Kingdom)

33 patients with advanced malignant melanoma were studied after intravenous administration of 131I-labeled Fab fragments specific for p97, an oncofetal glycoprotein of human melanoma. In all, 47 gamma...Full Text Available

1983-12-01

300

Irradiation with and without razoxane in the treatment of incompletely resected or inoperable recurrent rectal cancer. Results of a small randomized multicenter study  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, and toxicity. Results: The combined ...

2007-07-15

301

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) ...

1995-10-01

302

Ewing's sarcoma in childhood and adolescence  

International Nuclear Information System (INIS)

A review of main issues in diagnosing, complex treatment and prognosis of Ewing's sarcoma is presented. Current trend in chemotherapy, radiotherapy and surgery of the disease is discussed. Unfavourable prognosis is attributed to the systematic character of the disease, necessitating a complex therapeutic approach. Attempts to make an optimal combination of the three therapeutic methods in order to improve survival and reduce the rate of post-treatment complications are analyzed. 37 refs., 4 tabs. (author).

303

Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects  

UK PubMed Central (United Kingdom)

The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric...Full Text Available

2008-01-01

304

Dose specification and quality assurance of RTOG protocol 95-17; a cooperative group study of 192Ir breast implants as sole therapy  

UK PubMed Central (United Kingdom)

PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available

2007-12-01

305

Bullous pemphigoid after radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.

1988-02-01

306

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

307

Lower energy cost with oil-free compressors; Oelfrei verdichtende Kompressoren senken die Energiekosten deutlich  

Energy Technology Data Exchange (ETDEWEB)

The energy cost of compressors accounts for up to 90% of the total cost. Oil-free compressors could reduce the cost almost by half, i.e. annual savings of 112,500 DM would be achievable. [German] Ueber die Gesamtlaufzeit betrachtet, machen die Energiekosten bei Verdichtern bis zu 90% der Gesamtkosten aus. Deshalb muss bei der Auswahl von Kompressoren dem Energieverbrauch besondere Aufmerksamkeit geschenkt werden. Mit oelfreien Kolbenkompressoren liessen sich in einem speziellen Fall die Kosten fast halbieren, was jaehrlichen Einsparungen von 112 500 DM entspricht. (orig.)

2000-07-01

308

Kombinierte Flie?- und Grenzbedingungen  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Eine genauere Untersuchung der bekannten Modelle isotropen Materialverhaltens (z.B. von Mises, Tresca, Mohr-Coulomb, Drucker-Prager usw.) zeigt, dass sie selten mit Versuchsergebnissen ?bereinstimmen. Modelle mit inkompressiblen Eigenschaften sch?tzen oft das Materialverhalten bei mehraxialen Zugbelastungen falsch ein. Beim Flie?en unter Druck liefern die Modelle mit kompressiblen Eigenschaften unzul?ssige Werte der Querkontraktionszahl. Erfahrungen zeigen, dass es schwierig ist, mehrdimensionales Materialverhalten bei h?ufig fehlenden Informationen werkstoffgerecht abzubilden. Viele Modelle liefern akzeptable Ergebnisse nur f?r bestimmte Bereiche des Spannungsraumes. Diese Beobachtung hat auf die Idee gef?hrt, ,,bew?hrte?? Modelle miteinander zu verbinden. In diesem Artike...

2008-01-01

309

High efficiency by advanced power plant engineering. Siemens PG: Best solutions for high-tech steam turbines; Hoehere Wirkungsgrade durch moderne Kraftwerkstechnik. Siemens PG: Best solutions fuer High-tech-Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

A consequent use of computers and standardized components enables high efficiency for steam turbines while produced at lower manufacturing cost as shown here in the Muehlheim company of Siemens Power Generation, where steam turbines are produced for new stations and retrofitted elder power plants. [German] Auch eine ueber hundert Jahre alte Technik bietet Raum fuer Innovationen: Konsequenter Computereinsatz und standardisierte Baureihen ermoeglichen bei Dampfturbinen hohe Wirkungsgrade bei relativ niedrigen Fertigungskosten - umgesetzt im Werk Muelheim der Siemens Power Generation, wo Dampfturbinen fuer Neuanlagen und zum Modernisieren bestehender Kraftwerke entstehen. (orig.)

2002-07-01

310

Environmental aspects concerning medium- and highvoltage cables; Umweltfragen bei Mittel- und Hochspannungskabeln  

Energy Technology Data Exchange (ETDEWEB)

Environmental compatibility is nowadays a very important part in the case of planing, construction, operation and maintainance of cable systems. A lot of laws and orders have to be observed. Some new aspects concerning the removal of oil filled cables and the consideration of electromagnetic fields even for cabels will be presented. (orig.) [Deutsch] Der Umweltschutz ist heute unverzichtbarer Bestandteil der Planung, Bau, Betrieb und Instandhaltung von Kabelanlagen. Zahlreiche Gesetze und Verordnungen sind hierbei zu beachten. Der Verfasser stellt einige Neuerungen im Zusammenhang mit dem Ausbau und Oelkabeln vor und erlaeutert die auch bei Kabeln zu beruecksichtigenden elektromagnetischen Felder. (orig.)

1997-09-22

311

Die Behandlung laryngealer Bewegungsst?rungen mit Botulinumtoxinen  

British Library Electronic Table of Contents (United Kingdom)

ZusammenfassungDie Botulinumtoxinbehandlung ist eine etablierte Methode in der Behandlung von spasmodischen Dysphonien. Prinzipiell kann eine Behandlung transkutan zervikal, transoral mit einer gebogenen Spritze unter visueller Kontrolle w?hrend der Laryngoskopie sowie mittels flexibler Endoskope bzw. Videoendoskope mit Arbeitskanal erfolgen. Insbesondere die transkutane Injektion unter Larynx-EMG-Kontrolle (LEMG) ist ein verh?ltnism??ig einfaches Verfahren. Aufgrund der visuellen Kontrolle bei transoral oder flexibel transnasal verabreichtem Botulinumtoxin scheint eine bessere Wirksamkeit zu bestehen. Aus verschiedenen Gr?nden kann dieses Verfahren aber nicht bei allen Patienten verwendet werden. Wir berichten ?ber unsere Erfahrungen mit den verschiedenen Techniken und unsere Erw?gungen i...

2007-01-01

312

Condition assessment of steam turbines after long operating periods; Zustandsbeurteilung von Dampfturbinen nach langer Betriebszeit  

Energy Technology Data Exchange (ETDEWEB)

Turbine sets are inspected at their overhaul intervals throughout their operating lives. Using three examples, the present article describes the procedure in the inspection and assessment of steam turbines during overhauls and also deals with rehabilitation measures. In addition to the usual non-destructive tests and the recording of findings, computational life assessments are also considered. (orig.) [Deutsch] Turbosaetze werden waehrend ihrer Betriebszeit anlaesslich von Revisionen ueberprueft. Anhand von drei Beispielen wird in diesem Beitrag die Vorgehensweise bei der Pruefung und Bewertung von Dampfturbinen bei Revisionen und fuer Rehabilitationsmassnahmen dargestellt. Neben ueblichen zerstoerungsfreien Pruefungen und Befundaufnahmen erfolgten in Verbindung damit auch rechnerische Lebensdauerbewertungen. (orig.)

1999-07-01

313

Proposal of procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions; Proposta de procedimentos para evitar erros em radioterapia baseados em licoes aprendidas de exposicoes acidentais  

Energy Technology Data Exchange (ETDEWEB)

In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...

2007-07-01

314

The grid regulator as alternative for transformers; Der Netzregler als Alternative zur Transformatorenstation  

Energy Technology Data Exchange (ETDEWEB)

Line conditioners control voltage isolated in external conductors. Changes of Stern-Delta connections involve voltage drop in a nonloaded external conductor and are therefore compensated. The payback period of a line conditioner lasts normally between one to three years, according to the investment cost for the alternative medium-sized voltage to be constructed. (GL)

2005-11-01

315

The VerTech Pit Method - wet oxidation as an alternative to thermal sewage sludge treatment; Das VerTech-Tiefschachtverfahren - Nassoxidation als Alternative zur thermischen Klaerschlammbehandlung  

Energy Technology Data Exchange (ETDEWEB)

The VerTech Pit Method for wet oxidation of municipal sewage sludge offers an ecologically and economically advantageous alternative for dealing with sewage and special sludges. Europe`s first commercial plant has now been commissioned in Apeldoorn in the Netherlands following industrial-scale trials in the USA. Up to its present stage of operation the plant has achieved a high degree of reduction of solid residues and a favourable resource and environmental profile, thus impressively confirming earlier results. It is amply in keeping with the landfill criteria laid down in the Household Waste Technical Code. Furthermore, the potential sludge throughput has been found to exceed the projected value. [Deutsch] Mit dem VerTech-Tiefschachtverfahren zur Nassoxidation kommunaler Klaerschlaemme steht ein alternatives Verfahren zur Behandlung von Klaer- und Sonderschlaemmen zur Verfuegung, das oekologische und wirtschaftliche ...

1994-10-01

316

Novel procedure for an efficient and sparing cleaning procedure of turbines; Neues chemisches On-site-Reinigungsverfahren zur Wirkungsgraderhoehung von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

A new procedure for an efficient and sparing cleaning procedure of turbines was developed. The procedure uses cleaning and passivation chemicals that solve effectively and homogeneously salt and ferrous oxide coatings from turbines, avoiding attacks from corrosion, plugging and unbalances. In several high-pressure and condensation turbines the cleaning procedure has been already put into practice. (orig.)

2004-07-01

317

Das kalte Licht der Olefine  

British Library Electronic Table of Contents (United Kingdom)

Abstract Der folgende Artikel setzt die Reihe unserer ChiuZ-Beitrge zur Chemi- und Biolumineszenz mit einer interessanten und neuen experimentellen Arbeit zum -kalten Licht- spezieller ungesttigter Verbindungen fort, deren Anwendung auch in der modernen Zeit der Nanotechnologie im biochemischen bzw. medizinisch-chemischen Labor vllig neue Akzente gesetzt hat.

2011-01-01

318

CORIS[sup (TM)]: A knowledge based system for pitting corrosion. CORIS trademark : Wissensbasiertes System zur Lochkorrosion  

Energy Technology Data Exchange (ETDEWEB)

A knowledge based system for pitting corrosion is presented. It can be used for material selection for specific pitting corrosion conditions or to check the suitability of a chosen material. The user can enter his own knowledge. The expert system is an integration of traditional expert system technology and neural networks. (orig.)

1993-10-01

319

Biomass of tomorrow: Banknotes. Two new disposal methods as an alternative to combustion. Die Biomasse von morgen: Banknoten. Zwei neue Verwertungsverfahren als Alternative zur Verbrennung  

Energy Technology Data Exchange (ETDEWEB)

Old banknotes may be tomorrow's biomass. Experts on biowaste are investigating two new processes for disposal of the 1000 tonnes of old bills sorted out every year which may be an alternative to combustion. The author presents details.

1999-06-01

320

Bibliographic study on molybdenum biokinetics. Literaturstudie zur Biokinetik von Molybdaen  

Energy Technology Data Exchange (ETDEWEB)

This bibliographical study compiles and analyzes findings about the metabolism and resorption of molybdenum. Besides including studies on the physiology of molybdenum 99, a general survey is given on molybdenum in the environment and on its physiological behaviour. In particular, information on the dependence of molybdenum resorption on various factors, such as the chemical form, antagonisms etc., are gathered from literature. These factors have to be considered for sensibly carrying out necessary experiments.

1988-05-01

321

Reducing the life cycle cost of pumps by means of failure reduction; Lebenszykluskosten bei Pumpen senken durch Fehlerreduzierung  

Energy Technology Data Exchange (ETDEWEB)

Giving many examples, the contribution shows how pump operators may influence the life, efficiency and overall cost of their pumps. Further, it is shown that both the detection of unfavourable or non-optimal operating conditions and the identification of causes necessitate extensive knowledge and experience. (orig.)

2008-12-15

322

Objectivisation of the monitoring of teaching aims among technical college and polytechnic students. Objektivierung der Lehrzielkontrollen bei Fachoberschuelern und Fachhochschuelern  

Energy Technology Data Exchange (ETDEWEB)

Tests based on teaching aims, which can be used for objective determination of the level of knowledge of technical college and polytechnic students, are developed at the vocational training centre of the DMT. The data are gathered completely anonymously by a computer program and evaluated economically. (orig.)

1993-12-09

323

Impacts of defects on the serviceability of shafts and housings of steam turbines; Einfluss von Fehlstellen auf die Gebrauchseigenschaften von Wellen und Gehaeusen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The evaluation of possible manufacture-based defects in turbine shafts and housings for component serviceability relevance is of particular interest not only in post-manufacturing NDT but also in evaluation of NDT results obtained by in-service inspections of components with long service lives. The results discussed in the paper are summarized as follows: Most of the examined natural defects in the forgings and castings behave like cracks under the simulated operating conditions and hence may well be evaluated by fracture mechanical methods for their serviceability relevance determined by crack propagation under fatigue, creep and creep-fatigue stress. The empirical correlation of true defect size and US testing results (echo signal, echodynamics, attenuation) permits improved determination of true defect sizes in the turbine components. Care has to be taken to select the proper testing and evaluation methods in compliance with defect types. (orig./MM) [Deutsch] Die ...

1996-12-31

324

FLUTAN 2.0. Input specifications  

Energy Technology Data Exchange (ETDEWEB)

FLUTAN is a highly vectorized computer code for 3D fluiddynamic and thermal-hydraulic analyses in Cartesian or cylinder coordinates. It is related to the family of COMMIX codes originally developed at Argonne National Laboratory, USA, and particularly to COMMIX-1A and COMMIX-1B, which were made available to FZK in the frame of cooperation contracts within the fast reactor safety field. FLUTAN 2.0 is an improved version of the FLUTAN code released in 1992. It offers some additional innovations, e.g. the QUICK-LECUSSO-FRAM techniques for reducing numerical diffusion in the k-{epsilon} turbulence model equations; a higher sophisticated wall model for specifying a mass flow outside the surface walls together with its flow path and its associated inlet and outlet flow temperatures; and a revised and upgraded pressure boundary condition to fully include the outlet cells in the solution process of the conservation equations. Last but not least, a so-called visualization option based on VISART ...

1996-05-01

325

Automatic segmentation of thoracic and pelvic CT images for radiotherapy planning using implicit anatomic knowledge and organ-specific segmentation strategies  

Energy Technology Data Exchange (ETDEWEB)

Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...

2008-03-21

326

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant dose, SSD. The reduction ...

1991-11-01

327

Stereotactic body radiotherapy for unresectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A statistically significant association between ...

2010-01-01

328

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, ...

1981-11-01

329

Proximal cholangiocarcinoma. Prognostic factor and effectiveness of post operative radiotherapy  

International Nuclear Information System (INIS)

To define the prognostic factors after surgical resection and evaluate the effectiveness of Post Operative Radiotherapy (PORT) in cases with cholangiocarcinoma, 44 cases with proximal cholangiocarcinoma were examined. The mean observation period was 20.6 months, and the survival rates 1, 3 and 5 years after the resection were 79.9%, 59.8% and 39.3%, respectively. Univariate analysis revealed that the presence of lymph node metastasis and absence of PORT were significant poor prognostic factors. Multivariate analysis revealed that the absence of PORT was a significant poor prognostic factor. The survival rates for 1 and 3 years after the resection were 80.0% and 40.0% in the curable A/B and PORT (-) group, and 100% and 53.3% in curable C and PORT (+) group. There were no local reccurences in the pathologically classified hm2 and em2 patients who underwent PORT. Even when the surgical margin is positive for the carcinoma pathologically, it is possible to avoid local ...

2000-10-01

330

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of radiotherapy of non-malignant diseases because ...

1983-01-01

331

Local control and survival of Ewing's sarcoma in children with radiotherapy and chemotherapy without radical surgery  

International Nuclear Information System (INIS)

The present study was undertaken in 27 children with localized Ewing's sarcoma treated at our hospital. In 9 cases the lesion was central and in 18 peripheral. Treatment consisted of: 1) Chemotherapy with 6 drugs (vincristine, cyclophosphamide, methotrexate, bleomycin, dactinomycin and doxorubicin) for one year in all patients; 2) Radiotherapy in 24 patients at a dose of 30-40 Gy in the entire bone with a booster dose of 10-15 Gy in the lesion. In 7 patients debulking surgery was performed followed by irradiation. Two cases with tumor in expendable bones and one with extensive destructive lesion in the tibia underwent radical surgery. One patient suffered local recurrence (femur) and 6 developed distant metastases. The remaining 20 (74%) patients were alive and tumor-free after follow-up periods of 17-80 months. Among the 12 patients with extremity lesions who were alive, 7 (58%) had minimal or mild treatment sequelae, 2 moderate, and 3 severe sequelae but no ...

332

Lessons drawn from the accidents occurred in the framework of conventional external radiotherapy;Lecons tirees des accidents survenus dans le cadre de la radiotherapie externe conventionnelle  

Energy Technology Data Exchange (ETDEWEB)

This study examines some radiation accidents occurred in the past. This information has been systematically assessed to get global lessons. The experience feedback shows that the most of accidents happened in certain conditions. These conditions can be distributed in four categories: 1- perception and vigilance in occupation: accidental exposure happened by lack of vigilance in details and lack of vigilance and perception; 2- procedures: accidental exposure happened following a lack of procedures or control that were not enough complete, not enough documented or not completely implemented; 3- training and understanding: accidental exposures happened because the personnel was not enough qualified and educated, did not get the general training nor the the necessary specialized training; 4- liabilities: accidental exposures happened following lacks and ambiguity in the definition of functions of the personnel and in the hierarchy liabilities. In these precise cases the safety tasks have ...

2009-12-15

333

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...

334

Intracavity irradiation with deferred radioactive load technique, remote control high activity sources  

Energy Technology Data Exchange (ETDEWEB)

From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant ...

1988-01-01

335

Hyperfractionated radiotherapy with simultaneous chemotherapy in Ewing's sarcoma  

International Nuclear Information System (INIS)

In 1981, the German Society of Pediatric Oncology initiated a multi-institutional study for the treatment of Ewing's sarcoma. The protocol (Cooperative Ewing's Sarcoma Study, CESS 81) consisted of four courses of a four-drug-regimen (VACA), each course taking nine weeks. Local therapy (radical surgery or resection plus irradiation or radiotherapy alone) was performed after the second course. The results of CESS 81 can be summarized as follows: VACA-chemotherapy is effective in controlling systemic disease. Initial tumor mass and response to initial chemotherapy are of major prognostic value for local control and survival. Permanent local control is a problem, especially in irradiated patients. The high local failure rate in irradiated patients in CESS 81 could be attributable to the following reasons: Late start of local therapy (after 18 weeks of chemotherapy), uneven distribution of prognostic parameters: Large tumors were more often irradiated than operated, ...

336

Ewing's sarcoma. Evaluation of radiotherapy and control of the primary tumor  

International Nuclear Information System (INIS)

From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).

337

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

338

Bilateral femoral neck fractures following pelvic irradiation  

International Nuclear Information System (INIS)

Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was ...

339

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

340

The reirradiation of the cavum cancer. Experience of the oncology center Ibn-Rochd of Casablanca (C.O.I.R.); La reirradiation du cancer du cavum. Experience du centre d'oncologie Ibn-Rochd de Casablanca (COIR)  

Energy Technology Data Exchange (ETDEWEB)

The radiotherapy is the prime treatment for the cavum cancer. It is also useful to treat the tumor recurrences, in this case the reirradiation stays the only efficient therapy option to give a correct local control. The reirradiation, exclusive or in association with other therapies can contribute to the local control of cavum cancer recurrences with a survival rate at five years of 36 to 58%. (N.C.)

2006-11-15

341

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers and physicians. (author)

342

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

343

Palliation of radiation-related mucositis  

Energy Technology Data Exchange (ETDEWEB)

Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.

1990-01-01

344

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

345

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

346

Development of power supplies for compact medical synchrotron  

International Nuclear Information System (INIS)

A compact medical synchrotron is being developed which aims to promote the advanced radiotherapy based on the accelerator. As it is small-sized, a high field dipole magnet of 3 T at 200 kA is used. It is excited by the discharge current of the capacitor bank of which waveform is half sinusoidal. To provide with the flat field of 10 - 20 #mu#s duration for the multi-turn injection an additional power supply is developed. For the quadrupole magnet a 100 kHz switch-mode power supply is adopted as it requires the fine tuning and accurate field tracking to the dipole field. (author)

2005-06-01

347

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They were enrolled on ...

2000-01-15

348

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

349

Computer-assisted rotation and multiple stationary irradiation technique  

International Nuclear Information System (INIS)

A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).

350

Acute lymphoblastic leukemia with multiple cytogenetic abnormalities secondary to treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-06-01

351

A case of Ewing's sarcoma treated successfully with chemotherapy and radiotherapy  

International Nuclear Information System (INIS)

We encountered a case of Ewing's sarcoma. The patient was a 19 year-old girl, who visited a local physician because of pain in the left scapular region, and was referred to us. Roentgenograms of her left scapula revealed an irregular moth-eaten shadow which was suspected to be a malignant bone tumor. The histological diagnosis of Ewing's sarcoma was comfirmed by needle biopsy. The initial stage of treatment consisted of radiation therapy (6000 rads) and chemotherapy (VAC and ADR). At the end of the initial stage, the symptoms were improved, the size of the local lesion was reduced on the roentgenogram and there was no evidence of distant metastases. (author).

352

Semi-automated segmentation of the sigmoid and descending colon for radiotherapy planning using the fast marching method  

International Nuclear Information System (INIS)

A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon centre line between ...

2010-09-21

353

Radiotherapy for brain metastases from renal cell cancer. Should whole-brain radiotherapy be added to stereotactic radiosurgery? Analysis of 88 patients  

International Nuclear Information System (INIS)

Purpose: To evaluate the role of stereotactic radiosurgery (SRS) and whole-brain radiotherapy (WBRT) for the treatment of brain metastases in patients with renal cell cancer (RCC). Patients and methods: 88 patients were treated with either SRS (n = 51) or SRS + WBRT (n = 17) for one to three lesions, or with WBRT (n = 20) for more than three brain metastases. Overall survival (OS), intracerebral control (IC) and local control (LC) were retrospectively analyzed. Six potential prognostic factors were assessed: age, gender, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Results: The median times for OS, IC, and LC from the time of diagnosis were 11, 9, and 10 months. The median OS times for SRS, SRS + WBRT, and WBRT were 12, 16, and 2 months. Addition of WBRT to the SRS improved IC (p = 0.032) but not OS (p = 0.703). On multivariate analyses, improved OS was ...

2010-04-01

354

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for radiotherapy, the majority ...

2006-02-01

355

Phase I Study of Conformal Radiotherapy and Concurrent Full-Dose Gemcitabine with Erlotinib for Unresected Pancreatic Cancer.  

Science.gov (United States)

PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting toxicity, except for Grade 3 anorexia or Grade 3 fatigue alone. RESULTS: A total of 20 patients were ...

2011-05-01

356

Monte Carlo treatment planning for photon and electron beams  

International Nuclear Information System (INIS)

During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have been introduced. To ...

2007-04-01

357

Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice  

International Nuclear Information System (INIS)

A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse cytophotometry, "3H-thymidine uptake labeling ...

358

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E/sub ...

1981-12-01

359

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E2 (19 +/- 8 ...

1981-12-01

360

Concurrent Chemoradiotherapy in Resected Extrahepatic Cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: Extrahepatic cholangiocarcinoma is a rare malignancy. Despite radical resection, survival remains poor, with high rates of local and distant failure. To clarify the role of radiotherapy with chemotherapy, we performed a retrospective analysis of resected patients who had undergone chemoradiotherapy. Methods and Materials: A total of 45 patients (13 with proximal and 32 with distal disease) underwent resection plus radiotherapy (median dose, 50.4 Gy). All but 1 patient received concurrent fluoropyrimidine-based chemotherapy. The median follow-up was 30 months for all patients and 40 months for survivors. Results: Of the 45 patients, 33 underwent adjuvant radiotherapy, and 12 were treated neoadjuvantly. The 5-year actuarial overall survival, disease-free survival, metastasis-free survival, and locoregional control rates were 33%, 37%, 42%, and 78%, respectively. The median survival was 34 months. No patient died ...

2009-01-01

361

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the advantage of dose distribution and biological ...

1995-03-01

362

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, contrast enhanced CT ...

1996-11-01

363

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation; Duraverdickung am Rand intrakranieller, duranaher Raumforderungen in der MRT. Histologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor invasion into the dura ...

1997-11-01

364

The future of refrigeration and air conditioning. The master shows in restriction. Expert discussion on the work of the UNEP Technology and Economics Assessment Panel. Zur Zukunft der Kaelte und Klimatechnik. In der Beschraenkung zeigt sich der Meister. Ein Fachgespraech zur Arbeit des UNEP Technology and Economics Assessment Panels  

Energy Technology Data Exchange (ETDEWEB)

On behalf of the United Nations Environment Programme (UNEP) a study has been established by the Refrigeration, Air Conditioning and Heat Pump Technical Options Committee in which famous experts of refrigeration technology compiled facts which allow for a reliable prospect of real possibilities of changing from fluorine hydrogen to ozone innoxious substitutes and substitute technologies. With regard to the organization, a division into 6 committees for the establishment of the study has been made: 1. Refrigeration Options Committee, 2. Foams Options Committee, 3. Solvents, Coatings and Adhesives Options Committee, 4. Aerosols, Sterilants and Miscellaneous Uses Options Committee, 5. Halons Technical Options Committee and 6. Economic Options Committee. (BWI).

1992-09-01

365

Low-pressure steam turbine retrofits; Nachruestung von Niederdruck-Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

LP steam turbine retrofits are generally undertaken as a result of mechanical problems, for example due to stress corrosion cracking, torsional vibration or erosion. They present plant operators with an opportunity to introduce advanced aerodynamic technology, and at the same time improve efficiency and availability. Standard components, the majority proven in long-term service, can be used to obtain a permanent solution to the problems. In several European countries, retrofits have been carried out on intact LP steam turbines owned by utilities whose primary motivation is efficiency improvement. (orig.) [Deutsch] Niederdruck-Dampfturbinen werden in der Regel nur dann nachgeruestet, wenn waehrend des Betriebes Probleme durch Spannungsrisskorrosion, Torsionsschwingungen oder Erosion auftreten. In solchen Faellen bietet sich die Gelegenheit, eine moderne aerodynamische Loesung zu waehlen, die gleichzeitig Wirkungsgrad und Verfuegbarkeit verbessert. Es wird gezeigt, dass hierfuer eine ...

1996-09-01

366

International symposium: concepts for the treatment of wastewater in the rural areas of Europe. Proceedings; Internationales Symposium: Konzepte zur Abwasserbehandlung im laendlichen Raum Europas. Tagungsband  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the symposium, experts reviewed the state of the art of decentralized waste water treatment in Europe. In the second part, exemplary solutions in Poland and the Czech Republic were presented. The final part was dedicated to future concepts and strategies. [German] Im Herbst letzten Jahres hat die Kommunale Umwelt-AktioN U.A.N. in einer Abfolge von drei Abwasserfachsymposien Expertenrunden zum Austausch ueber den aktuellen Stand des Wissens zum Thema dezentrale Abwasserbehandlung veranstaltet. Mit dem Internationalen Symposium 'Konzepte zur Abwasserbehandlung im laendlichen Raum Europas' in Celle hat das Projekt der U.A.N. seinen Abschluss gefunden. Der Konzeption des Projektes entsprechend haben im 1. Teil des Symposiums Experten ueber den Stand der Entwicklung auf dem Sektor der dezentralen Abwasserbehandlung in Deutschland berichtet. Im 2. Teil unserer Fachtagung wurden europaeische Beispiele fuer dezentrale Loesungen aus ...

2000-07-01

367

Calculation of vapor diffusion systems in supply air systems; Verfahren zur Bemessung von Dampfdiffusionsstrecken in Zuluftanlagen  

Energy Technology Data Exchange (ETDEWEB)

For the calculation of humidifier systems in supply air systems nomographs and appropriate software are not sufficient alone. System design factors must be considered, also. On the basis of a clear definition interpretation examples are described and remarks for the effective installation of steam distribution systems are given. (orig.) [Deutsch] Es ist nicht zu empfehlen, Befeuchterstrecken bzw. Dampfdiffusionsstrecken ausschliesslich ueber Nomogramme oder ueber eine entsprechende Software auszulegen. Zumindest sollte vorher genauestens geprueft werden, welche Parameter in die Berechnung mit einfliessen. Zur exakten Berechnung der Absorptionsstrecken in Zuluftsystemen muessen auch anlagenspezifische Faktoren beruecksichtigt werden. Die Erfahrung hat jedoch gezeigt, dass dem Begriff `Befeuchterstrecke` zu wenig Aufmerksamkeit gewidmet wird. Hierdurch koennen Fehler entstehen, die nur mit relativ hohem finanziellem Aufwand wieder zu korrigieren sind. Grundsaetzlich ...

1998-10-01

368

Application of pressure oxidation for the decomposition of organic pollutants in highly contaminated waters and suspensions as an alternative to hazardous-waste incineration. Final report; Anwendung der Druckoxidation fuer den Abbau organischer Schadstoffe in hochkontaminierten Waessern und Suspensionen als Alternative zur Sonderabfallverbrennung. Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The results of the experiments on the pressure oxidation of oil and fat in waste waters shows that the final COD and TOC values decrease with growing temperature and reaction time and decreasing initial concentration. Oxidation of oil and fat in waste water is no straight forward procedure. Therefore it should be compared in the individual case with laternative methods in terms of cost and economic efficiency. (EF) [Deutsch] Die Ergebnisse der Versuche zur Druckoxidation von Oel und Fett in Abwaessern zeigten, dass sich die CSB- und TOC- Endkonzentration verringerte mit steigender Temperatur, Reaktionszeit und verringerter Ausgangskonzentration. Die Oxidierbarkeit von Oel und Fett in Abwaessern ist sehr schwierig. Deshalb sollte in jedem Einzelfall ein Vergleich mit alternativen Verfahren bezueglich Aufwand und Wirtschaftlichkeit vorgenommen werden. (EF)

1993-03-30

369

Action and locality principle for noncommutative scalar field theories; Wirkungs- und Lokalitaetsprinzip fuer nichtkommutative skalare Feldtheorien  

Energy Technology Data Exchange (ETDEWEB)

We develop a general framework for the formulation of the action principle and the noether theorem for classical noncommutative field theories. We give a concrete example of an algebra that fits into this framework. It describes a scalar field theory on noncommutative minkowski space. We develop a notion of locality for this algebra and investigate the locality properties of localised interaction terms. This leads us to the definition of local functionals on the field algebra. We propose a scheme for the quantisation of these functionals. (orig.) [German] Wir entwickeln eine allgemeinen rahmen, der es erlaubt, das wirkungsprinzip und das noether-theorem fuer klassische nichtkommutative feldtheorien zu formulieren. Als ein konkretes beispiel betrachten wir eine algebra, die sich in diesem rahmen einfuegt, und die eine skalare feldtheorie auf dem nichtkommutativen minkowski-raum beschreibt. Fuer diese algebra wird ein lokalitaetsbegriff entwickelt und untersucht, welche ...

2003-12-01

370

VDMA contribution to functional safety of turbo-machines - A necessary risk reduction by means of safety function for steam turbines; VDMA-Beitrag zur Funktionalen Sicherheit von Turbomaschinen. Notwendige Risikoreduktion durch Schutzfunktionen fuer Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.

2010-07-01

371

Utilization of red mud from the Bayer process for producing Ferrari cements. Verwendung von Rotschlamm nach dem Bayer-Verfahren zur Herstellung von Ferrari-Zementen  

Energy Technology Data Exchange (ETDEWEB)

A report is given of investigations into the possibility of utilizing red mud from the Bayer process for producing Ferrari cements. On repeated burning at 1450deg C suitable mixtures of red mud with silica and lime form a clinker with a low free lime content from which Ferrari cement can be produced. The average 28-day compressive strengths of cements produced from this clinker are so encouraging that further investigations are appropriate. (orig.).

1989-11-01

372

Manipulator for internal testing of a container. Manipulator zur Innenpruefung eines Behaelters  

Energy Technology Data Exchange (ETDEWEB)

A manipulator for checking the inside of a vertical, flange-shaped collector of a horizontal steam generator consists of a rotating mast with bearings at the top and bottom ends with a support that can be moved along the length of the mast for the checking system mountings. The support is propelled by a drive spindle placed parallel to the mast with its drive head bearing in the support and locked into a toothed rack attached to the mast. The checking system mountings are fitted in or on the walls of the support and are very close to the box-shaped support. Their retractable arms are hinged.

1985-04-11

373

FLUTAN input specifications  

Energy Technology Data Exchange (ETDEWEB)

FLUTAN is a highly vectorized computer code for 3-D fluiddynamic and thermal-hydraulic analyses in cartesian and cylinder coordinates. It is related to the family of COMMIX codes originally developed at Argonne National Laboratory, USA. To a large extent, FLUTAN relies on basic concepts and structures imported from COMMIX-1B and COMMIX-2 which were made available to KfK in the frame of cooperation contracts in the fast reactor safety field. While on the one hand not all features of the original COMMIX versions have been implemented in FLUTAN, the code on the other hand includes some essential innovative options like CRESOR solution algorithm, general 3-dimensional rebalacing scheme for solving the pressure equation, and LECUSSO-QUICK-FRAM techniques suitable for reducing `numerical diffusion` in both the enthalphy and momentum equations. This report provides users with detailed input instructions, presents formulations of the various model options, and explains by means of ...

1991-05-01

374

European Research Centre for Air Pollution Control Measures (PEF) 1. Status colloquium of PEF. Projekt Europaeisches Forschungszentrum fuer Massnahmen zur Luftreinhaltung (PEF). 1. Statuskolloquium des PEF  

Energy Technology Data Exchange (ETDEWEB)

Progress reports on the European Research Centre for Air Pollution Control Measures project are presented. Topics covered were: assessment and analysis of the impacts of airborne pollutants on forest trees, and distinction from other potential causes of recent forest dieback; research into atmospheric dispersion, conversion and deposition of airborne pollutants; development and optimization of industrial technical processes to reduce or avoid emissions; and providing instruments and making recommendations to the industrial and political sectors.

1985-01-01

375

Effect of additives in the positive active mass of lead batteries. Zur Wirkung von Zusaetzen in der positiven Aktivmasse des Bleiakkumulators  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the capacity and service life of cathodes, the effect of carboxy-methyl cellulose, soot, silica gel and fibres was examined. Structural tests and electrical and electro-chemical measurements are used for this. The additives can affect crystallization in the manufacturing stage of the electrodes and can increase the storage capacity for water and the electronic conductivity. They act to stabilize the mass in cyclic operation. Soot additive has little effect on the properties of the electrode, but the other substances increase the service life or the use of the mass. (LU).

1984-01-01

376

Design of low-pressure blading for steam turbines. Zur Auslegung von ND-Beschaufelungen fuer Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In recent years very good experience has been accumulated with self-supporting low-pressure blades. Today blades are constructed up to a length of 1060 mm (50 Hz) or 1360 mm (25 Hz). In this process modern computational methods from aerodynamics and also from mechanics are employed. The further development of computer technology also permits new methods, for example the use of curved fixed blading as well as the optimization of existing designs. (orig.).

1989-08-01

377

CRS Processing, an alternative to PreSDM?; CRS Processing als Alternative zur Prestack Tiefenmigration?  

Energy Technology Data Exchange (ETDEWEB)

In the presented case study CRS processing was able to improve the overall data quality of the processed lines in terms of signal-to-noise ratio and imaging. The complex geology is causing serious problems in conventional NMO/DMO processing that were solved by CRS processing. Even a depth processing with velocities calculated from CRS attributes gives good results similar to those from PreSDM in terms of the velocity field. Data quality of poststack depth migrated CRS stacks is even better than the image from PreSDM. (orig.)

2004-07-01

378

Anaerob treatment of organic wastes as an alternative to deposition, combustion and composting. Die anaerobe Behandlung von Abfaellen als Alternative zur Deponierung, Verbrennung und Kompostierung  

Energy Technology Data Exchange (ETDEWEB)

The first biogas plant using the Plauen method has been operated without failures in the Saxon Vogtland since May 1987. This large scale anaerob treatment plant which is the first one in Germany handles besides agricultural recidual substance both municipal and industrial organic residues. The results show clearly that fermentation is a real alternative to composting, combusting and deponing. (orig.)

1994-01-01

379

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der Darstellung der Meningitis ...

1994-12-31

380

Development of an electrically rechargeable zink/air demonstration module; Entwicklung eines elektrisch wiederaufladbaren Zink-Luft-Demonstrationsmoduls  

Energy Technology Data Exchange (ETDEWEB)

A team at the Paul Scherrer Institute (PSI) recently achieved a breakthrough in the development of an environment-friendly and rechargeable battery with novel electrodes. The energy storage density of a rechargeable 12 V/20 Ah zinc/air battery could be increased to 100 watt hours per kilogramme - three times as much as conventional lead accumulators. 20-Ah cells could be charged and discharged 55 times in 1000 hours without any loss of capacity worth mentioning. This is a remarkable cycle stability. (orig.) [German] Einem Team des Paul Scherrer Instituts (PSI) ist kuerzlich bei der Entwicklung einer umweltfreundlichen und wiederaufladbaren Batterie mit neuartigen Elektroden der Durchbruch gelungen. Dabei konnte die Energiespeicherdichte einer wiederaufladbaren 12 V/20 Ah-Zink-Luft-Batterie auf 100 Wattstunden pro Kilogramm gesteigert werden - dreimal soviel wie bei konventionellen Bleiakkumulatoren. 20-Ah-Zellen konnten in 1000 Stunden ohne ...

1999-10-01

381

Calculation of ventilation efficiency and of load situations for load-relieving air conduction systems; Berechnung der Lueftungseffektivitaet und der Belastungssituation fuer lastmindernde Luftfuehrungen  

Energy Technology Data Exchange (ETDEWEB)

Zone modeling permits taking account of the effect of load-relieving air conduction systems in the planning of HVAC plants. Although this only supplies average values for the degree of load and height of the fresh air layer rather than a detailed description of concentration and temperature distributions in the room, it is quite sufficient for the planning of load-relieving air conduction systems. Moreover, the cost of zone modeling in the planning of HVAC plants remains within reasonable limits. Upscale planning, instruments can thus be reserved for more exacting problems. (orig.) [Deutsch] Zonenmodelle erlauben die Wirkung lastmindernder Luftfuehrungen bei der Planung von RLT-Anlagen zu beruecksichtigen. Sie liefern zwar nur Mittelwerte fuer den Belastungsgrad und die Hoehe der Zuluftschicht und keine detaillierte Konzentrations- und Temperaturverteilungen im Raum. Diese Werte reichen jedoch fuer die Planung lastmindernder Luftfuehrungskonzepte aus. Zudem ist der ...

1994-12-31

382

Atlas and toolbook of MR mammography; Lehratlas der MR-Mammographie  

Energy Technology Data Exchange (ETDEWEB)

This richly illustrated toolbook and atlas contains information on all aspects of nmr diagnostic imaging of benign or malignant neoplasms of female and male mammary glands. It offers pinpointed guidance and insight for vocational training and continuing training of radiology assistants, students and medical radiologists. (orig./AJ) [German] Die MRT als hochaufloesendes und schaedigungsfreies Diagnostikum gewinnt gerade in der emotional stark besetzten Mammadiagnostik zunehmend an Bedeutung. Dennoch beherrschen nur wenige Zentren im deutschsprachigen Raum diese Technik, die - eine hohe Reproduzierbarkeit bei fehlender Belastung fuer die Patientin bietet, - invasive Karzinome bereits ab einer Groesse von 5 mm mit hoher Zuverlaessigkeit ausschliessen kann und - gerade bei widerspruechlichen Befunden zwischen klinischer Untersuchung, Roentgenmammographie und perkutaner Biopsie eine wesentliche Entscheidungshilfe bieten kann. Aus einem der ...

2000-07-01

383

Aspects of the development of mechanical superchargers; Aspekte der Entwicklung mechanischer Lader  

Energy Technology Data Exchange (ETDEWEB)

Internal combustion engines with mechanically driven superchargers are known for good performance at low engine speeds and fast response times under fluctuating loads. Application engineers can choose between superchargers with and without internal compression - the familiar roots (blower) type or true compressors - for supercharging an internal combustion engine. This article by DaimlerChrysler describes two options for improving the partial load behaviour of mechanically supercharged internal combustion engines with compressors. (orig.) [German] Die Aufladung mit mechanisch angetriebenen Verdraengerladern zeichnet sich durch guten Druckaufbau bei niedrigen Drehzahlen und gute Dynamik bei Lastwechseln aus. Fuer die Applikation am Verbrennungsmotor koennen Maschinen ohne innere Verdichtung - wie die bekannten Roots-Geblaese - oder Maschinen mit innerer Verdichtung - Kompressoren im eigentlichen Sinne - zum Einsatz kommen. In diesem Beitrag von ...

2001-11-01

384

New atomic energy law - international and national developments. Proceedings; Neues Atomenergierecht - internationale und nationale Entwicklungen. Tagungsbericht  

Energy Technology Data Exchange (ETDEWEB)

Two of the working sessions of the meeting were devoted to aspects of international atomic energy law; the international character of the meeting was also reflected by the home countries of the members of the panel discussion concluding the working sessions. There was substantial reason to put emphasis on the international dimension of the topics discussed. In June 1994, the Nuclear Safety Convention had been signed in Vienna by diplomatic representatives of the signatory countries, and this Convention marks a signpost in the history of international atomic energy law. At the time the meeting was held, negotiations for improving the international nuclear lability law, which had been dragging on since 1989, had come to a stalemate. The meeting offered a suitable forum for taking a scientific approach to tackle the complex problems involved in reshaping the law on nuclear safety and nuclear liability. The third working session of the meeting has been discussing topics relating to the ...

1995-12-31

385

Acoustic analysis of combustion engines; Die Akustikanalyse von Verbrennungsmotoren  

Energy Technology Data Exchange (ETDEWEB)

For millions of people general noise and especially traffic noise are the main sources of environmental pollution. The increasingly stricter noise pollution abatement limiting values laid down by the law call for motor vehicle noise pollution abatement measures. Within the framework of today`s cost- and performance-oriented automobile and engine development developing engineers are required to reduce noise levels. The present state of the art is described and future possibilities of combustion engine structure-borne noise calculation and optimization are discussed from the point of view of K + P Computerunterstuetzte Strukturanalysen GmbH. (orig.) [Deutsch] Laerm allgemein und dabei speziell wiederum der Verkehrslaerm steht fuer Millionen von Menschen an allererster Stelle der persoenlichen Belastung durch die Umwelt. Zur Minderung der Laermbelastung werden vom Gesetzgeber immer schaerfere Grenzwerte vorgeschrieben, die dazu zwingen, Massnahmen ...

1995-04-01

386

Ventilation on demand: The efficient way to ensure clean air; Bedarfsgeregelte Lueftung: Dicke Luft wirtschaftlich verhindern  

Energy Technology Data Exchange (ETDEWEB)

Ventilation systems must ensure high room air quality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)

1997-11-01

387

Using n-ZnO-Al as window layer in pilot production of CIGSSe solar modules: Status and trends. Status of CIGSSe pilot scale production at Munich; Einsatz von n-ZnO:Al als Fensterschicht in der Pilotfertigung von CIGSSe-Solarmodulen: Status and Entwicklung. Status der CIGSSe-Pilotfertigung in Muenchen  

Energy Technology Data Exchange (ETDEWEB)

Shell Solar GmbH is working on a variant of the so-called stacked elemental layer process for CIGSSe absorber production. The metal films resp. the selenium are deposited on the Mb electrode at room temperature by DC sputtering (CIG) or evaporation (Se) and then processed into semiconductors by rapid thermal annealing (RTP). Currently, the mean efficiency of the pilot plant is i 12.6 {+-} 0.2 % for non-sealed 30 x 30 cm{sup 2} modules, the key efficiency is 13.0 %. In addition to the 30 x 30 cm{sup 2} pilot line, a small series of 60x90cm2 modules was constructed in December 2004. Here, the mean efficiency was 13.0 percent while the average module power was higher than 60 W. The contribution also describes investigations of ceramically sputtered n-ZnO:Al layers with reduced Al concedntrations of 1 percent and on reactively sputtered n-ZnO.Al layers from the double roller magnetron. (orig.) [German] Bei Shell Solar GmbH wird eine Variante des sogenannten ...

2005-07-01

388

The need for action in the housing ventilation area is essential; Bei der Wohnungslueftung besteht grosser Handlungsbedarf  

Energy Technology Data Exchange (ETDEWEB)

This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.

2003-07-01

389

Seconds capacity reserve and heat consumption with different operating procedures of steam turbines. Sekundenleistungsreserve und Waermeverbrauch bei verschiedenen Betriebsarten von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).

1989-09-01

390

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues; Abfaelle mit natuerlicher Radioaktivitaet. Teil 1. Bewertung und Ueberwachung von Materialien und Rueckstaenden  

Energy Technology Data Exchange (ETDEWEB)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far. [German] Die novellierte Strahlenschutzverordnung von 2001 befasst sich auch mit natuerlich vorkommenden radioaktiven Stoffen. Bei ihrer Verwertung oder Beseitigung ergeben sich praktische Fragen, die beachtet werden muessen. Erfahrungen auf diesem Gebiet liegen bisher kaum vor. (orig.)

2003-03-01

391

KOMET 650: investigation of materials for use in steam turbines at temperatures up to 650 C; KOMET 650: Erprobung von Materialien fuer den Einsatz in Dampfturbinen bei Temperaturen bis 650 C  

Energy Technology Data Exchange (ETDEWEB)

The report covers the results of exposing materials for steam turbines to increased steam temperatures in two modules of the KOMET 650 testing facility at the Westfalen power plant. Ferritic/martensitic steels with 9 to 12% Cr and austenite and nickel-based alloys were investigated. Some experimental coatings on low-alloy Cr steel were also tested. The principal findings are presented. It will become possible to construct advanced power stations to be operated at higher temperatures. (orig.)

2008-07-01

392

Influence of tempering on microstructure and hardness of high-temperature 9%Cr-steels; Einfluss des Anlassens auf Gefuege und Haerte warmfester 9%Cr-Staehle  

Energy Technology Data Exchange (ETDEWEB)

The influences of temperature and duration of tempering on hardness and microstructure were investigated at high-temperature martensitic and low-carbon steels with 9% chrome and the further alloying elements molybdenium, vanadium, niobium and partially tungsten. After austenitizing and subsequent air cooling the steels were tempered at temperatures below, at and above Ac{sub 1b} for different times and finally a hardness test was performed. Making use of the temperature dependence of the hardness tempering diagrams were constructed and the Hollomon-Jaffe-Parameter on the three steels was determined within its application limits. Micrographs of the structure shows the formation of the carbides and the martensite. At tempering temperatures below Ac{sub 1b} a decrease of hardness occurs, above Ac{sub 1b}, a hardness rise due to the partial austenitizing was obtained. While hardening below Ac{sub 1b}, the tempering quality increases from P 91, NF 616 to E 911. (orig.) [Deutsch] An ...

1999-06-01

393

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: Patients with the tested present-day prosthetic heart valves can be safely imaged by ...

2000-02-01

394

Impacts of grain structure and texture on the high-temperature fatigue in ODS superalloys; Einfluss der Kornstruktur und der Textur auf die Hochtemperaturermuedung von ODS-Superlegierungen  

Energy Technology Data Exchange (ETDEWEB)

The study examines the isothermal fatigue properties of novel ODS iron-base or nickel-base superalloys at temperatures of 850 C and 1050 C. The materials are different in grain structure and texture, so that particularly the effects of grain structures and textures can be studied. In order to also perform examinations of creep-fatigue interactions, various load cycles are applied. It is shown that the LCF-affected life of the grain structures of both alloy types is determined by the elastic modulus. The cyclic lifetimes determined by the conventional Manson-Coffin method for both alloy types exhibit differences of up to two orders of magnitude. Using the product of the total strain range and the elastic modulus, however, will yield precise life predictions. Under conditions of LCF stress only, the grain structure has no effect on the materials` service life, other than in the case of creep-fatigue, but the grain structure has a decisive influence on the damage mechanisms and the course ...

1995-12-31

395

Focus on the customer, the novel approach of energy companies. Terms and definitions, instruments, suitability assessment of key-account management strategies. Kundenorientierung bei EVU. Begriff-Instrumente-Eignung  

Energy Technology Data Exchange (ETDEWEB)

With increasing liberalization of the energy sector, German suppliers of line-transmitted energy find themselves in an utterly changed sales environment, forcing companies and utilities to elaborate for the first time management policies and strategies that will ensure loyalty of their present customers, and help to solicit new customers. The article here explains some major terms and instruments used in designing key-account management strategies, as well as general procedures for suitability assessment. (orig/CB)

1999-06-01

396

Electric vehicle getting up speed soon?; Kommt E-Mobil in Fahrt?  

Energy Technology Data Exchange (ETDEWEB)

A novel zinc-air battery might soon enhance the mileage and applications of electric vehicles. The battery named Zoxy battery weighs 80% less than a conventional lead battery, but has an equal amount of energy in store. (orig./CB) [Deutsch] Eine neuartige Zink-Luft-Batterie koennte vor allem dem Elektroauto groessere Reichweiten und neue Einsatzmoeglichkeiten erschliessen. Die sogenannte Zoxy-Batterie ist 80% leichter als eine herkoemmliche Bleibatterie - bei gleichem Energiegehalt. (orig.)

1997-12-31

397

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

398

Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging); Moeglichkeiten der digitalen Bildverstaerkerradiographie am Beispiel des Digital Spot Imaging (DSI)  

Energy Technology Data Exchange (ETDEWEB)

We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge sharpness, DSI yields a significantly inferior assessment compared with the film/screen technique. (orig./MG) ...

1995-10-01

399

Development of a production technology for PbSnCaAl alloys for batteries  

Energy Technology Data Exchange (ETDEWEB)

A new generation of lead alloys for making lead batteries is being introduced in highly developed countries. A very important characteristic of these alloys is the presence of Ca, Al and Sn. Such alloys have the property of stabilizing the amount of gas emitted as a result of the decomposition of the electrolyte on the level of pure lead i.e. significantly smaller than lead alloys containing Se e.g. PbSb 1.7Se. Such alloys have not been produced in Poland so far. - In this paper we are presenting the method and equipment used to produce a pilot portion of PbSnCaAl alloy (mass approximately 80 Mg) on an industrial scale at HMN ''Szopienice'' S.A. lead refinery. We also present the results of the tests regarding the chemical homogeneity of the alloy produced, as well as its structural and casting properties. On the basis of the tests conducted it has been found that the method is industrially adequate and as such it has been introduced into the ...

2000-07-01

400

Corrosion inhibition of steel in crude oil storage tanks  

Energy Technology Data Exchange (ETDEWEB)

The corrosion behavior of steel in water from certain oil fields with various organic inhibitors was studied by applying potentiodynamic technique at pH 5.9. The inhibitors which were used include 2-methylbenzimidazole (I), 2-mercaptobenzimidazole (II), 2-mercapto-5-methylbenzimidazole (III), and 2-mercaptothiazole (IV). The inhibiting efficiency of the different additives was evaluated from their anodic and cathodic polarization curves at different temperatures. A comparative study of curve fitting procedures using the kinetic thermodynamic model and those utilizing well-known adsorption isotherms was undertaken. Three types of isotherms were used, Langmuir, Frumkin and Flory-Huggins isotherm. The results show that the kinetic-thermodynamic model and Flory-Huggins isotherms are more suitable to fit the data for the four inhibitors, at all applied temperatures. From the values of binding constants, K, the order of inhibitor efficiency is: III > IV > II > I and thus ...

2003-04-01

401

Correct monitoring of stationary battery systems; Stationaere Batteriesysteme richtig ueberwacht  

Energy Technology Data Exchange (ETDEWEB)

There are many applications that necessitate reliable and permanent power supply, e.g. power stations, airports, computer centers or hospitals. The stationary battery systems must be monitored by efficient systems, e.g. Batlog. (orig.) [Deutsch] Viele Anwendungen verlangen eine permanent verfuegbare und zuverlaessige Stromversorgung. Kraftwerke, Flughaefen, Rechenzentren oder Krankenhaeuser muessen ihre Prozesse auch bei einem Netzausfall oder einer Versorgungsunterbrechung weiterbetreiben. Dies gelingt nur, wenn sich der entsprechende Energiespeicher in einsatzbereitem Zustand befindet. Die Ueberwachung der stationaeren Batterieanlagen erfordert leistungsfaehige Systeme wie Batlog. (orig.)

1998-10-01

402

Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung kombinierter PET/CT-Systeme bereitet den Weg fuer eine simultane ...

2004-09-01

403

Manufacture and properties of molybdenum-rhenium alloys  

Energy Technology Data Exchange (ETDEWEB)

It is necessary to measure strength and creep behavior to guarantee the safe and reliable usage of refractory alloys at extremely high temperatures. In the literature there is very little information available about the properties of Mo-Re alloys at temperatures higher than 1000 C. A special test facility has been designed and built for stress-rupture testing at very high temperatures (up to 3000 C) of refractory metals and alloys in inert atmospheres. - The stress-rupture strength as well as the creep behavior of molybdenum-rhenium alloys with rhenium contents between 41 and 51 wt.% have been determined at temperatures ranging from 1200 to 2000 C, and rupture times of up to 10 hours using this facility. Previous measurements of stress-rupture strength and creep behavior of pure rhenium have been compared with the measurement results of Mo-Re alloys. - The discussion of the values measured is based on metallographic test results and scanning electron microscopy (SEM) images of Mo-Re ...

2001-07-01

404

Progress report within the series of GRS-F progress reports on reactor safety, sponsored by the Federal Ministry of Economics and Labour. Period: 1 July - 31 December 2002; Berichte ueber vom Bundesministerium fuer Wirtschaft und Arbeit gefoerderte Forschungsvorhaben auf dem Gebiet der Reaktorsicherheit. Berichtszeitraum: 01. Juli - 31. Dezember 2002  

Energy Technology Data Exchange (ETDEWEB)

Within its competence for energy research, the Bundesministerium fuer Wirtschaft und Arbeit (BMWA) (Federal Ministry of Economics and Technology) sponsors investigations into the safety of nuclear power plants. The objective of these investigations is to provide fundamental knowledge, procedures and methods to contribute to realistic safety assessments of nuclear installations, to the further development of safety technology and to make use of the potential of innovative safety-related approaches. The Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, by order to the BMWi, continuously issues information on the status of such investigations by publishing semi-annual and annual progress reports within the series of GRS-F-Fortschrittsberichte (GRS-F-Progress Reports). Each progress report represents a compilation of individual reports about the objectives, work performed, results achieved, next steps of the work etc. The individual reports are prepared in a standard form by the ...

2002-07-01

405

Investigation of the influence of nitrogen on the pitting corrosion of high alloyed austenitic Cr-Ni-Mo-steels (Part II); Untersuchungen zum Einfluss des Stickstoffs auf das Lochkorrosionsverhalten hochlegierter austenitischer Cr-Ni-Mo-Staehle (Teil II)  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steel (18% Cr, 12% Ni, Mo gradation between 0,06 to 3,6%) had been solution nitrided. By step-by-step removing, the samples could be prepared with various surface contents of nitrogen from 0.04 to 0.42%. In two test series the influence of nitrogen had been determined. The susceptibility against pitting corrosion of these samples had been tested by the chronopotentiostatical method. For the investigated steel composition and the used corrosion system there is no influence of molybdenum on the effectiveness of nitrogen. The effectiveness of nitrogen can be described by the factor 25 in the PRE. By the investigation of the surfaces with the XPS analysis, it could be shown that the passivation and the pit nucleation is influenced by nitrogen. In these ranges NO{sub x}, NH{sub x}, and NH{sub z}-spectra have been detected. Bound Mo was found in steels containing molybdenum. It is assumed that the repassivation mechanisms of N and Mo work independently of each other. ...

2004-11-01

406

Forming of Mo and Ti silicides by means of injection molding; Formgebung von Molybdaen- und Titansiliziden ueber das Pulvermetallformspritzen  

Energy Technology Data Exchange (ETDEWEB)

The report describes the processing of TiSi{sub 2}, MoSi{sub 2} and Ti{sub 5}Si{sub 3} by means of metal injection molding (MIM). First, the sintering activities of the three materials were investigated. After this, the viscosities of different mixtures of organic binder and powders of the three materials were determined, and in the final stage, components were produced by injection molding, the binder was removed, and the components were sintered. TiSi{sub 2} in powder form could be sintered to more than 95% of its theoretical density after 4 h at 1386 C. Metallographic analyses proved leaktightness of the component at this density. In the case of Ti{sub 5}Si{sub 3}, it was found that this material requires very long sintering times and high sintering temperatures for sintering to about 94% of its theoretical density. Metallographic analyses showed that only about 90% of the theoretical density was reached. MoSi{sub 2} in powder form could be sintered to only 90% of its theoretical ...

1994-10-01

407

Second malignancies after treatment for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: Some former retrospective studies have suggested that patients with Ewing's sarcoma might have a very high risk for developing secondary sarcomas if treated with radiotherapy. We have evaluated the risk of second malignancies (SM) in patients treated in the German Cooperative Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and methods: From January 1981 through June 1991, a total number of 674 patients was registered in the two multicentric Ewing's sarcoma trials CESS 81 (1981 through 1985) and CESS 86 (1986 through June 1991). The systemic treatment consisted in both studies of a four-drug-chemotherapy (VACA= vincristine, actinomycin D, cyclophosphamide and adriamycin; or VAIA= vincristine, actinomycin D, ifosfamide and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy was either complete surgery or surgery plus postoperative radiotherapy with 36-46Gy or ...

408

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

409

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and steps required for implementing a dose ...

2003-01-01

410

Surgical management of osteoradionecrosis of the temporal bone  

Energy Technology Data Exchange (ETDEWEB)

The surgical management of osteoradionecrosis of the temporal bone has met with limited success because of the difficulty in accurate assessment of the viability of nonnecrotic bone intraoperatively. Failure to resect all nonviable bone results in recurrence of a necrotic focus. With the use of hyperbaric oxygen therapy to stabilize marginal bone and oral tetracycline to label viable bone preoperatively, removal of all nonviable bone can be accomplished. Postoperatively, a second course of hyperbaric therapy enhances wound healing, thus assuring a successful outcome. This article details a successful systematic approach that was developed to resect a necrotic focus in the temporal bone of a 10-year-old boy who had undergone a full course of radiotherapy for treatment of a rhabdomyosarcoma.

1988-03-01

411

Surgical aspects of intestinal injury due to pelvic radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.

1985-04-01

412

Second malignancies after treatment for Ewing's sarcoma: a report of the CESS-studies  

International Nuclear Information System (INIS)

Purpose: During recent years, more intensified systemic and local treatment regimens have increased the 5-year survival figures in localized Ewing's sarcoma to more than 60%. There is, however, concern about the risk of second malignancies (SM) in long-term survivors. We have analyzed the second malignancies in patients treated in the German Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and Methods: From January 1981 through June 1991, 674 patients were registered in the two sequential multicentric Ewing's sarcoma trials CESS 81 (recruitment period 1981-1985) and CESS 86 (1986-1991). The systemic treatment in both studies consisted of a four-drug-regimen (VACA = vincristine, actinomycin D, cyclophosphamide, and adriamycin; or VAIA = vincristine, actinomycin D, ifosfamide, and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy in curative patients was either complete surgery (n = 162), surgery plus ...

1998-09-01

413

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

414

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

415

Radiation-induced large intracranial vessel occlusive vasculopathy.  

Science.gov (United States)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, and histologic features ...

1980-01-01

416

Radiation-induced large intracranial vessel occlusive vasculopathy  

Energy Technology Data Exchange (ETDEWEB)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and confirmed by pathologic examination. The clinical, angiographic, and histologic features ...

1980-01-01

417

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 tabs., 138 refs.

1988-01-01

418

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a patient and deposited in a phantom at a large ...

2004-12-01

419

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

420

Optimizing the conditioning regimen for allogeneic stem-cell transplantation in acute myeloid leukemia; dose intensity is still in need  

British Library Electronic Table of Contents (United Kingdom)

Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...

2011-01-01

421

Oligodendroglioma occurring after radiation therapy for pituitary adenoma  

Energy Technology Data Exchange (ETDEWEB)

A 38 year old male dentist developed an oligodendroglioma of the left medial temporal lobe and parasellar region 12 years after radiotherapy with 6600 rads for acromegaly. The 30 cases of radiation-induced gliomas reported in the English literature are reviewed and analysed. The criteria for defining radiation-induced tumours of the central nervous system are proposed as follows: the tumour has a long quiescent ''latency period'', a location in the previously irradiated field, a verified histological difference from a primary condition, and does not arise from a primary condition associated with a genetic syndrome such as neurofibromatosis or tuberous sclerosis. The reported case fulfilled these criteria but appears to be the only reported radiation-induced oligodendroglioma.

1987-12-01

422

New procedures. Comprehensive staging of lung cancer by MRI  

International Nuclear Information System (INIS)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.)

2010-08-01

423

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.

424

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

425

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

426

Ewing's Sarcoma : a study of 38 cases  

International Nuclear Information System (INIS)

A retrospective study of Ewing's Sarcoma at The Armed Forces Malignant Diseases Treatment Centre, Command Hospital, Pune, is presented. A total of 38 cases over a period of thirteen years have been studied. Males predominate slightly, and the common age group on presentation has been in the second and third decade. Humerus, pelvis and femur are the bones commonly affected. The initial line of management has been primarily radiotherapy, which has been over the years supplemented by combination chemotherapy. All the cases achieved remission, though only 32 cases (84 per cent) had complete remission, and the remaining only partial remission. The overall survival in those offered aggressive therapy has been over 50 per cent in two years. The present policy in the management of these cases is discussed. (author). 4 tabs.

427

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

428

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

429

Chemoradiotherapy of unresectable and recurrent cholangiocarcinoma  

International Nuclear Information System (INIS)

This study is for chemoradiotherapy of unresectable and recurrent cholangiocarcinoma (CCC). Between April 2005 and March 2007, 5 patients were evaluated for unresectable and recurrent CCC. All patients were performed percutaneous transhepatic biliary drainage (PTBD) and treated with chemoradiotherapy. The radiation method was an external beam radiotherapy (EBRT) and remote after loading system (RALS). The chemotherapy was 5-fluorouracil (FU) and gemcitabine by intravenous injection. Three patients had unresectable and 2 had recurrent CCC. As for the side effects, 4 patients had a slight neutropenia and 1 had an uncontrollable gastric bleeding. No patient had cholangitis. The mean survival time for unresectable and recurrent CCC was 13.7 months and 17 months, respectively. Our results indicated that chemoradiotherapy had been consistent with efficacy in patients with unresectable and recurrent CCC. (author)

2007-11-01

430

Alpha particles for treatment of disseminated melanoma  

International Nuclear Information System (INIS)

Invading melanoma spreads to local and unpredictable distant location at the early stages of its development. It is justifiable, therefore, to classify the disease as a systemic disorder. This requires a systemic treatment that reaches all melanoma cells irrespective of whether they are singly dispersed and in circulation or already forming solid tumours of various sizes. Targeted radiotherapy affects directly and selectively cancer cells provided an appropriate radionuclide and its carrier are chosen. Melanoma is a pigmented tumour. Methylene blue (MTB)) accumulates selectively in melanoma cells due to its exceptionally high affinity to melanin. MTB serves, therefore, as a carrier for radionuclides. "2"1"1At-MTB has proved to be particularly effective in treating disseminated melanoma when administered systemically and, at the same time, non-toxic to normal non-pigmented and pigmented organs. (authors)

431

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

432

Results of the project 'combustion modelling' (BKM II); Ergebnisse des Projekts 'Brennkammermodellierung' (BKM II)  

Energy Technology Data Exchange (ETDEWEB)

In the year 1996 the spheres of competence of several DLR-Institutes working in the areas of fluid dynamics, reaction kinetics, combustion, numerical methods and laser measuring techniques have been brought together while contributing to the internal DLR project 'combustion chamber modelling (BKM)', in order to proceed with the computational simulation of combustion processes in combustion chambers of gas turbines. The main issue was the development of a research code for numerical simulation of fluid flow in real combustion chambers. Here the development of computational models of physical and chemical processes was emphasized, among other processes the formation of soot was treated. Moreover, a worldwide outstanding database of measured data for the purpose of code validation has been created within the framework of the BKM project using the laboratory facilities of the DLR, which are in Germany unique for the experimental investigation of the various processes in ...

2002-07-01

433

Fission product speciation in Phebus tests FPT0 and FPT1 and the possible influence of boron  

Energy Technology Data Exchange (ETDEWEB)

The thermochemical calculations performed with a large number of elements to describe the chemical system in a Phebus FP test allow the following conclusions: The metallic absorber materials play a significant role in fission product speciation. At around 1000 C and above, silver iodide is the dominant iodine carrier in a full steam atmosphere in both FPT0 and FPT1. At lower temperatures, cadmium iodide takes over. In a reduced environment, indium iodide becomes important. Caesium iodide does certainly appear; at certain test conditions it becomes the major iodine transporting vehicle. But its role is not greater than that of the other iodides. It has more chances in FPT1 than in FPT0. Chlorine, which was present in FPT0 as a contaminant in relatively large amounts, does not prevent the iodine from forming Csl. Both share the caesium like partners. The evolution of caesium chloride and iodide proceeds in parallel. When CsCl is abundant, Csl is strong, too. Should boron be added to the ...

1996-01-01

434

VGB guideline, instructions for the procurement of steam turbine plants. Benefits for contractor and client; VGB-Richtlinie, Anleitung zur Beschaffung von Dampfturbinenanlagen. Nutzen fuer Besteller und Auftragnehmer  

Energy Technology Data Exchange (ETDEWEB)

The establishment of the domestic market in Europe requires rules for the assignment of orders, with which a standardization of the rules of competition can be achieved and with which a discrimination of individual bidders can be prevented. Clients and contractors of power station equipments equally are affected by the definitions for the assignment of orders. The contribution under consideration is a regulation for the procurement of steam turbine systems. It is a supplement of the European standard DIN EN 45510:1998. The regulation integrates the former terms of delivery of association of the electricity industry (VDEW) for steam turbines as well as the collection and evaluation of a multiplicity of experiences of the VGB regulations.

2008-07-01

435

The east-European energy situation. Slowing of economic growth cuts down on energy demand. Zur Energie-Situation in Osteuropa. Wachstumseinbussen mindern Energiebedarf  

Energy Technology Data Exchange (ETDEWEB)

The economic development of eastern Europe was associated during the last 15 years with the following average annual increases in energy consumption: Approximately 1% in the sectors industry, building and transport, almost 7% in the farming sector, approximately 3% in households, and nearly 4% in the municipal sector. This trend will not continue. As the economic system shifts from centrally planned to free economy and as the previously secluded economy is forced to face world market conditions as well as changed pars of exchange and conditions of payment, it not only experiences a transitory, sharp dip of economic growth in general but, in particular, drastic structural changes. - While there is to be expected, on the whole a slump in national economic growth, in tradiational branches of industry (e.g., metallurgy, the chemicals and textile industry) as well as in farming, such sectors as the service industry and small trade are expanding. (orig./UA).

1991-10-01

436

Steam turbines. A simulation model for nozzle group control; Dampfturbinen. Ein Simulationsmodell zur Duesengruppenregelung  

Energy Technology Data Exchange (ETDEWEB)

So far, publications in turbomachinery engineering have tended to neglect the description of control systems and strategies which could be converted into practical guidelines for turbine operation. The contribution describes the power station turbine as a basis for modelling the control stage. The solutions will serve as a basis for further type-specific investigations of the problem. [German] Eine vornehmlich regelungstechnisch ausgerichtete Beschreibung des thermodynamisch-mechanischen Wirkungsgeschehens im Bereich der Regelstufe von Dampfturbinen sowie deren Umsetzung in schluessige, betriebsrelevante Aussagen fehlen bislang in der Turbomaschinenliteratur. Im Beitrag werden am Beispiel der Kraftwerksturbine die Grundlagen fuer eine modelltechnische Nachbildung der Regelstufe entwickelt. Die Loesungen dienen als Ausgangsbasis fuer weitere typenspezifische Bearbeitungen dieses Problems. (orig.)

2000-07-01

437

Steam turbine blading with variable degree of reaction; Dampfturbinen-Beschaufelungen mit variablem Reaktionsgrad  

Energy Technology Data Exchange (ETDEWEB)

Liberalization and the associated necessity of providing, where possible, inexpensive electrical energy, has intensified still further the demand for higher efficiency steam turbines. Accordingly, continuous efforts are being taken to improve all the flow guiding components of a steam turbine. Special attention is given here to the blading. (orig.) [Deutsch] Die Liberalisierung und die damit verbundene Notwendigkeit, elektrische Energie moeglichst preisguenstig zur Verfuegung zu stellen, hat die Forderung nach hohen Wirkungsgraden von Dampfturbinen weiter verschaerft. Es werden daher kontinuierlich Anstrengungen unternommen, alle stroemungsfuehrenden Teile einer Dampfturbine zu verbessern. Das Hauptaugenmerk gilt dabei der Beschaufelung. (orig.)

1998-05-01

438

Soft factor 'felt comfort'. Room air quality, an important element; Soft-Factor Wohlbefinden. Raumluftqualitaet als wichtige Grundlage  

Energy Technology Data Exchange (ETDEWEB)

Facility management has long been regarded as a cost reduction measure, but it is also a means of raising the financial worth of a building so that landlords can get higher rents or sell the building at a better price. [German] Lange Zeit wurde Facility Management als eine Massnahme zur Kostensenkung angesehen. Heutzutage zeigt sich immer mehr, dass das Facility Management sehr viel umfassender zu verstehen ist: Der Wert eines Gebaeudes bemisst sich nicht allein an einer niedrigen Kostenquote, sondern er soll umfassend Investoren wie Mietern den hoechst moeglichen Nutzen bringen. Nicht allein der kostenguenstige Betrieb ist entscheidend, sondern der Wert des Gebaeudes muss insgesamt gesteigert werden. (orig.)

2002-07-01

439

Soft cooling with concrete: A simple system ensures a comfortable room climate; Sanfte Kuehlung aus Beton: Behagliches Raumklima mit einfachem System  

Energy Technology Data Exchange (ETDEWEB)

After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)

1999-10-01

440

Research activities of MPA, Stuttgart University, for enhanced safety and reliability of components under complex load; Forschungsaktivitaeten der MPA Universitaet Stuttgart zu Erhoehung der Sicherheit und Zuverlaessigkeit komplex beanspruchter Bauteile  

Energy Technology Data Exchange (ETDEWEB)

MPA research activities focus on fracture prevention and on the development of a generally applicable method of component integrity testing which, independent of the safety relevance of the components involved, is also part of ageing management. (orig.) [German] Die Forschungsaktivitaeten an der MPA im Hinblick auf die Erhoehung der Sicherheit und Zuverlaessigkeit komplex beanspruchter Bauteile orientieren sich an den Grundgedanken des Basissicherheitskonzepts (Prinzip des Bruchausschlusses). Zielsetzung war dabei die Entwicklung eines allgemein anwendbaren Nachweisverfahrens zur Komponentenintegritaet, das, abhaengig von der sicherheitstechnischen Relevanz der zu betrachtenden Komponenten, auch Bestandteil des Alterungsmanagements ist. (orig.)

2004-07-01

441

Regulation and secretion of Xanthomonas virulence factors  

British Library Electronic Table of Contents (United Kingdom)

Abstract Plant pathogenic bacteria of the genus Xanthomonas cause a variety of diseases in economically important monocotyledonous and dicotyledonous crop plants worldwide. Successful infection and bacterial multiplication in the host tissue often depend on the virulence factors secreted including adhesins, polysaccharides, LPS and degradative enzymes. One of the key pathogenicity factors is the type III secretion system, which injects effector proteins into the host cell cytosol to manipulate plant cellular processes such as basal defense to the benefit of the pathogen. The coordinated expression of bacterial virulence factors is orchestrated by quorum-sensing pathways, multiple two-component systems and transcriptional regulators such as Clp, Zur, FhrR, HrpX and HpaR. Furthermore, virule...

2010-01-01

442

Process to remove the residue of the waste gas scrubbing from firings, particularly bituminous coal power plants. Verfahren zur Beseitigung des Rueckstandes der Abgaswaesche von Feuerungen, insbesondere von Steinkohlenkraftwerken  

Energy Technology Data Exchange (ETDEWEB)

Calcium sulfate dihydrate which is co-produced in the scrubbing of waste gases from bituminous coal power plants is employed in the underground road securing after recrystallization. Beta-sulfate semi hydrate is obtained from the dihydrate by recrystallisation and it is used as such or as a stiff mixture with additives as a stowing material. Particularly fly ash from coal combustion units, washery refuses and development rocks from coal mining or slags from the metallurgical industry can be used as additives. The compressive and the bending tensile strength of the stowing material can be adjusted by the water content in case beta sulfate semihydrate is used as such.

1980-08-28

443

Process for the preparation of stable nonaqueous dispersions of water-soluble polymerisates. Verfahren zur herstellung zustands- und wirkungsstabiler nicht-waessriger dispersionen wasserloeslicher polymerisate  

Energy Technology Data Exchange (ETDEWEB)

This process for the preparation of nonaqueous dispersions of water-soluble polymerisates concerns compounds obtained by polymerization of water-soluble unsaturated ethylenic monomers in an emulsion of water in oil. The product is then dewatered to a maximum residual water content of 5% by means of microwaves. The process is azeotropic. The polymer has a molecular weight between 100,000 and 50,000,000, preferably between one and 10 million. Before treating with microwaves, the mixture is concentrated by conventional means until it has a polymer concentration between 20 and 65%, preferably between 40 and 60%. The microwaves have a wavelength between 0.1 and 30 cm. These polymer dispersions can be used in drilling fluids and as additives in tertiary oil recovery. 4 claims.

1983-09-07

444

Process for the manufacture of semi-rigid, folding solar generators manufactured from several coated solar cells. Verfahren zur Herstellung eines halbstarren, faltbaren, aus mehreren bedeckten Solarzellen (Cics) hergestellten Solargenerators  

Energy Technology Data Exchange (ETDEWEB)

This is a process for manufacturing a semi-rigid, folding solar generator manufactured from several coated solar cells (Cics), which has at least two folding parts connected together so as to turn by hinges, characterized by the following stages of the process: a) On the back of matrix subsections, in order to cover the connector, carbon fibre strips are glued on, which project over the upper or lower edge of each matrix subsection. b) The projecting ends of adjacent carbon fiber strips are connected with two carbon fibre strips. c) At least two matrix subsections are fixed in separately manufactured carbon fiber frames, and d) the carbon fiber frames, together with the matrix subsections are connected via hinges to a solar generator.

1985-10-31

445

Process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers. Verfahren zur Herstellung von Calciumsulfat-Dihydrat im Zuge der Entschwefelung von Rauchgasen aus Kraftwerkskesselfeuerungen  

Energy Technology Data Exchange (ETDEWEB)

This is a process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers, where the stack gases are introduced into a washing tower and are treated with a washing water suspension containing lime in the washing tower, where oxygen in the form of air or of air enriched in oxygen is also blown into the washing tower, and where the washing water suspension drawn off from the washing tower is fed back to the washing tower at a temperature of 45 to 50/sup 0/C in the circuit and at least part of the flow goes via a thickener and where calcium sulfate dihydrate slurry is drawn off from the thickener.

1986-06-12

446

On the binding effect of air pollution concentration values of the Technical Code Clean Air (TA Luft) in favor of the plant operator. Zur Bindungswirkung der Emissionswerte der TA Luft zugunsten des Anlagenbetreibers  

Energy Technology Data Exchange (ETDEWEB)

The dogmatic and constitutional basis as well as points of definition concerning the Technical Code Clean Air (TA Luft) are explained at first, followed by an assessment of the air pollution concentrations within the overall complex of the air pollution abatement measures, and an analyses of air pollution concentrations as a concretization of the state-of-the-art. In connection with the differentiation of the various applicability levels of TA Luft, the inhouse validy for authorities, the importance for law courts and, finally, the external binding effect for plant operators and possible third parties are discussed. At the center of attention are questions concerning validity claims and validity possibilities. (HSCH).

1991-01-01

447

Model-based automation system for demand-based heating and ventilation; Modellgestuetztes Mess- und Automatisierungssystem zur bedarfsgerechten Heizung und Lueftung  

Energy Technology Data Exchange (ETDEWEB)

Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)

2003-04-01

448

Merkblatt B3 - Elektrochemische Potentialmessungen zur Detektion von Bewehrungsstahlkorrosion  

British Library Electronic Table of Contents (United Kingdom)

Elektrochemische Potentialmessungen (auch Potentialfeldmessungen) haben sich seit Jahren bewahrt, Bereiche mit aktiver chloridinduzierter Korrosion an tausalzexponierten Bauwerken, wie z. B. Bruckentafeln sowie Zwischendecks und Bodenplatten von Parkhausern und Tiefgaragen nachzuweisen. Bereits 1990 erschien die erste Fassung des Merkblatts B3 der DGZfP. Das DAfStb Heft 422 (1991) - Prufung von Beton Empfehlungen und Hinweise zu DIN 1048 - enthielt die Potentialfeldmessung bzw. das Merkblatt B3 im Anhang. In Deutschland liegen somit zwei Jahrzehnte Erfahrungen mit den entsprechenden Regelwerken und naturlich auch in der praktischen Anwendung vor. In der Praxis zeigte sich jedoch auch, dass die Anwendung verbessert werden muss. Die Potentialmessung wurde vielfach sogar falsch durchgefuhrt, ...

2010-01-01

449

Measurements of environmental policy for air pollution abatement. Umweltpolitische Massnahmen zur Luftreinhaltung; Kosten-Nutzen-Analyse  

Energy Technology Data Exchange (ETDEWEB)

The first part of the study goes into the determination of efficient strategies for the reduction of air pollutants. The developed method is not only derived theoretically but is tested with the concrete example of emissions sources of a German state. The second part goes into the question what the government can do in order to attain that air pollution abatement measures recognized as being efficient will be put into practice. As market economy mechanisms have advantages over central state planning in the allocation of economic resources the question arises if not also for environmental protection market economy tools may contribute to an improvement of the efficiency of air pollution abatement. Therefore the suitability of different tools of environmental policy for the realization of efficient air pollution abatement is investigated and evaluated. This is again not done abstractly but with existing emission sources. (orig./HSCH). 32 figs., 12 tabs.

1993-01-01

450

Investigations for judging the working behaviour of components made of alloy 800 and alloy 617 under creep stress. Untersuchungen zur Beurteilung des Betriebsverhaltens kriechbeanspruchter Bauteile aus Alloy 800 und Alloy 617  

Energy Technology Data Exchange (ETDEWEB)

The program introduced here for determining and describing the multi-axial creep of pipes is based, on the one hand, on the results of the nuclear process heat prototype plant material program and, on the other hand, on the possible load conditions which arise for evaluating accidents or extreme working situations. The basis of a theoretical description of multi-axial creep is the invariant theory in which both the von Mises configuration change hypothesis and the Norton creep law are included. Combined tension and torsion are also considered in detail, the superimposition of cyclic stresses in the tensile threshold area is discussed and cases of partial relaxation are explained. Experimental results for the discussed loads are introduced, which have led to satisfactory agreement between theory and experiment. (orig./MM).

1987-01-01

451

Herausforderung: MDK-Pr?fung  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Hintergrund Seit 2005 finden schriftliche Anfragen und Vor-Ort-Pr?fungen durch den Medizinischen Dienst der Krankenversicherungen (MDK) statt. Diese spiegeln in ihren Ver?nderungen sowohl die Erfahrung der Kassen mit dem G-DRG-System (G-DRG German Diagnosis Related Groups) als auch der zust?ndigen ?rztlichen Mitarbeiter und des Krankenhauscontrollings wider. Wir wollten aufarbeiten, welche Entwicklung die MDK-Pr?fungen seit 2005 genommen haben. Hierf?r wurden s?mtliche Pr?fberichte seit Einf?hrung der Pr?fungen ausgewertet. Ergebnisse W?hrend anfangs haupts?chlich Fragen zur Kodier- und Dokumentationsqualit?t erfolgten, werden jetzt ?berwiegend Fehlbelegungspr?fungen durchgef?hrt. Zwischenzeitlich wurden konsequent die unterschiedlichen Klinikbereiche gepr?ft. Die Anfragen ...

2009-01-01

452

Gas and steam turbines: Power from fire; Gas- und Dampfturbinen: Kraft aus dem Feuer  

Energy Technology Data Exchange (ETDEWEB)

More than 200 years after the birth of the steam engine, the first thermal engine ever invented, thermal engines such as steam turbines, gas turbines or internal combustion engines are still driving most generators for electric power generation, most machines, and most vehicles, and this will remain so until far into the next century. (orig.) [Deutsch] Mit Waermekraftmaschinen wie Dampfturbinen, Gasturinen und Verbrennungsmotoren werden auch heute - mehr als 200 Jahre nach der technischen Reife der Dampfmaschine (der ersten Waermekraftmaschine) - die meisten Generatoren zur Stromerzeugung, die meisten Arbeitsmaschinen und die meisten Fahrzeuge angetrieben. Und dabei wird es auch bis weit in das 21. Jahrhundert bleiben. (orig.)

1996-02-01

453

Free air flows for the removal of pollutants from car parks. Air-conditioning systems without sheet-metal ducts as an alternative to transverse ventilation with sheet-metal ducts. Pt. 2. Freie Luftstroemungen entsorgen Parkraeume. RLT-Anlagen ohne Blechkanaele als Alternative zur Querlueftung mit Blechkanaelen. T. 2  

Energy Technology Data Exchange (ETDEWEB)

In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room air quality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)

1994-04-01

454

First experiences with the three guidelines for incorporation monitoring; Erste Erfahrungen mit den drei Richtlinien zur Inkorporationsueberwachung  

Energy Technology Data Exchange (ETDEWEB)

Three different guidelines define the methods to be used for the quantification of exposures due to the incorporation of radionuclides. The adoption of the Euratom-directive into German law requires the adaptation of these guidelines. With this process, the experiences with the practical application of these regulations must be taken into account. (orig.) [Deutsch] Die Ermittlung der Koerperdosis durch inkorporierte Radionuklide ist in drei Richtlinien des Bundesministeriums fuer Umwelt, Naturschutz und Reaktorsicherheit (BMU) geregelt. Die Umsetzung der Euratom-Direktive in deutsches Recht erfordert die Anpassung dieser Richtlinien. Dabei muessen die bisherigen Erfahrungen mit diesen Richtlinien beruecksichtigt werden. (orig.)

1998-12-31

455

Environmental protection, environmental pollution, and economic growth. A contribution to environmental economy in the framework of neoclassic models of growth. Umweltschutz, Umweltverschmutzung und Wirtschaftswachstum. Ein Beitrag zur Umweltoekonomie im Rahmen neoklassischer Wachstumsmodelle  

Energy Technology Data Exchange (ETDEWEB)

This book is mainly a comparison of the cost of pollution with the cost of environmental protection. As to the causes of pollution, a difference is made between pollutants that accumulate and pollutants that do not accumulate. Because of pollutant accumulation it is necessary to carry out both subsequent pollution abatement measures and to take preventive action which helps to avoid pollutant emission. Growth models serve to substantiate why such preventive action is both ecologically and economically useful as a rule. Finally the study makes a comparison between some tools of environmental protection. It stresses in particular that, if a duty on emissions is levied, the polluter has to bear all the cost of the pollution, while at the same time the quality of the environment can be more successfully improved than by emission standards alone.

1986-01-01

456

DGMK conference 'Energetic utilisation and recycling of waste and biomass'. Authors' manuscripts; Beitraege zur DGMK-Fachbereichstagung 'Energetische und stoffliche Nutzung von Abfaellen und Biomassen'. Autorenmanuskripte  

Energy Technology Data Exchange (ETDEWEB)

This conference of Deutsche Wissenschaftliche Gesellschaft fuer Erdoel, Erdgas und Kohle focused on energetic utilisation and recycling of waste materials and biomass, i.e. combustion, gasification and pyrolysis. Aspects of process control were gone into as well. [German] Die Fachbereichstagung der Deutschen Wissenschaftlichen Gesellschaft fuer Erdoel, Erdgas und Kohle beschaeftigte sich mit der energetischen und stofflichen Nutzung von Abfall und Biomasse. Verbrennung, Vergasung und Pyrolyse verschiedener Abfallstoffe sowie die Prozesssteuerung wurden eroertert.

2000-07-01

457

Controlled storage for distributed power generation and optimised energy flow in low-voltage mains; Steuerbare Speicher zur Optimierung des Energieflusses in Niederspannungsnetzen mit DEA  

Energy Technology Data Exchange (ETDEWEB)

This comprehensive final report for the Swiss Federal Office of Energy (SFOE) examines ways to optimise energy flows in mains networks that include distributed generation facilities. Increasing use of decentralised generation, its effects on the operation of low-voltage mains and the efficient use of the 400 V mains is discussed. The principles of operation and construction of controlled storage installations are discussed and concrete examples of their use in both grid-connected and island operation are quoted. Alternatives to storage are looked at from both the technical and economic points of view. The storage technologies used such as flywheels, supercaps, redox-flow batteries and lead-acid accumulators are briefly assessed and the results of simulations are discussed.

2005-07-01

458

Coatings for turbine rotors of Chinese hydropower plants. Final report; Anforderungsgerechte Beschichtung von Turbinenlaufraedern chinesischer Wasserkraftanlagen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The research project aimed at the selection or development of wear-reducing measures for submerged components of hydroelectric power plants. This comprised the optimisation of hydraulic profiles as well as materials testing for abrasion and cavitation. Another field of research was the development of appropriate application processes. (orig.) [German] Das Hauptziel des Forschungsvorhabens bestand in der Auswahl bzw. Entwicklung geeigneter Schutzmassnahmen zur Verschleissminderung an wasserberuehrten Komponenten von Wasserkraftanlagen. Diesem Ziel untergeordnet waren neben der Optimierung hydraulischer Profile auch Materialuntersuchungen hinsichtlich Verschleissbestaendigkeit gegenueber Abrasion und Kavitation. Ebenso war die Entwicklung geeigneter Applikationsprozesse ein wichtiger Bestandteil der Aufgabenstellung. (orig.)

2002-07-01

459

Anwendung von Trapezblechstegen im Bruckenbau  

British Library Electronic Table of Contents (United Kingdom)

Trapezblechstege im Bruckenbau kommen trotz der groen Vorteile, die diese Bauweise bietet, in Deutschland bisher nur an einem Pilotprojekt zur Anwendung. Durch die charakteristischen Eigenschaften des Trapezbleches entstehen konstruktive und wirtschaftliche Vorteile gegenuber herkommlichen Bruckenbauweisen. Allerdings lassen die aktuell gultigen Regelwerke aufgrund fehlender Kenntnis zum Tragverhalten und mangelnder Erfahrung keine wirtschaftliche Ausbildung zu. Dies zeigt sich am Beispiel des Pilotprojekts. Die Ausbildung der Verbundfuge wurde hier nur sehr unbefriedigend gelost und verdeutlicht somit die Notwendigkeit einfacher und praktikabler Verbindungsmoglichkeiten. Am Institut fur Leichtbau Entwerfen und Konstruieren der Universitat Stuttgart wurde in Zusammenarbeit mit dem Institut...

2009-01-01

460

Wear and friction coefficient of particle reinforced Ti-alloys  

Energy Technology Data Exchange (ETDEWEB)

Particulate Reinforced Titanium matrix composites (PRTi) exhibit some improved specific mechanical properties in comparison with those of unreinforced titanium alloys as a result of the combination of the high strength and stiffness of ceramic particles with the toughness and damage tolerance provided by the metal matrix. The poor tribological properties of the titanium exclude titanium alloys from applications where wear resistance is required (brakes, rotating parts, sliding parts). The addition of ceramic particles improves the tribological properties of metals sensitive to adhesive and /or abrasive wear significantly. In this work, the wear resistance and the friction coefficient of Ti6Al-6V-2Sn reinforced with TiC particles and Ti6Al-4V reinforced with SiC particles (prototype material) are compared with the unreinforced alloys. Pin on disc and pin on ring tests were carried out against standard steel (100Cr6) as a function of pressure, speed and temperature. The results show ...

2004-11-01

461

Studies of bearings to be used in high-temperature reactor plants. Final report; Lageruntersuchungen fuer Anwendungen in Hochtemperatur-Reaktor-Anlagen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Several components of high-temperature reactor units have roller bearings in order to carry out their motions without much friction. The use of such bearings poses friction and wear problems which cannot be mastered by commercial roller bearing technology. Possible improvements of coating, cage design and bearing materials as well as of their parameters were registered and studied. The service life of dry lubricated bearings was considerably improved. With a radial or axial load on the bearing of {>=} 10% of the static load, {approx_equal} 20x10{sup 6} rolling motions/actuations can be performed. The connections between surface compression and wear were determined, and optimum conditions for the transfer of lubricants from the cage onto the bearing race were worked out. Coating of corrosion-resistant roller bearing steels with the HRB-M{sub 0}S{sub 2} running-in coating could be proved. New cage designs and materials were tested with positive results. Alternative coatings (thin ...

1991-09-13

462

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly due to the contribution to viscosity from polymer entanglement becoming dominant over that from mean ...

2010-04-15

463

The Differentially Expressed Genes by Radiotherapy in the Patients with Uterine Cervix Cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA fragments. Expression pattern of down-regulated clone was examined using RT-PCR in ...

2001-12-15

464

Role of radiation therapy in the management of nonmetastatic Ewing's sarcoma of bone. Report of the intergroup Ewing's sarcoma study  

International Nuclear Information System (INIS)

The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in detail. Distant ...

465

Radiation therapy for gastrointestinal lymphomas: indications and techniques  

International Nuclear Information System (INIS)

Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...

466

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator beam, the dose ...

2003-08-17

467

Prognostic factors in the treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

From 1981 up to February 1985, a total of 93 protocol patients entered the study CESS 81. The protocol recommended an initial 18-week period of polychemotherapy (VACA) followed by local therapy and two additional cycles of chemotherapy. Local therapy consisted either of radical surgery or of incomplete resection plus postoperative irradiation with 36 Gy or of radiotherapy alone (46 and 60 Gy). Centrally located lesions were always irradiated with 60 Gy. This article summarizes the data after 5 years. Data of 93 patients were analysed in October 1986 after a median follow-up of 37 months. The projected 5-year survival is 50%. The relapse rate was 42%, distant relapses occurred in 19%, local (plus distant) relapses in 23%. Most of the relapses occurred during the first 3 years of observation. Failure rate was high in patients undergoing irradiation alone (44%). Initial tumour mass (> 100 ml) and histopathologic response to initial chemotherapy were identified as ...

468

Primary spinal epidural extraosseous Ewing's sarcoma: Report of five cases and literature review  

International Nuclear Information System (INIS)

Ewing's sarcoma is the most common malignant bone tumour occurring in children and adolescents and exists in two different clinico pathological entities: osseous Ewing's sarcoma (OES) and extraosseous Ewing's sarcoma (EES). Five cases of primary epidural EES are described, which presented with non-specific symptoms leading to a long diagnostic delay. The median age at diagnosis was 22 years (range 13-36 years). The median diagnostic delay was 3 months. All patients had one or more neurological deficits. All underwent surgical exploration with a laminectomy and partial resection followed by adjuvant radiotherapy to a dose of 46-50 Gy and chemotherapy with VAC (vincristine, adriamycin and cyclophosphamide) alternating with ICE (ifosphamide, cisplatin and etoposide) for at least six cycles. The mean follow-up period is 21.2 months (range 11-32 months). Four of the five patients achieved a complete remission and are disease free at the time of writing this report. Two ...

2001-08-01

469

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...

2006-01-15

470

Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated X-ray beams vs. intensity-modulated proton beams  

International Nuclear Information System (INIS)

Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for all targets and OAR with both treatment ...

2000-07-01

471

Impact of more intensive written information in patients having radical radiation therapy: Results of a prospective randomized phase III trial  

International Nuclear Information System (INIS)

Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of radiotherapy. A second ...

2010-08-01

472

Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal ...

2009-02-21

473

Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning  

International Nuclear Information System (INIS)

This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of the patient density matrix. It is ...

2003-09-07

474

Ewing's sarcoma treatment in Scandinavia 1984-1990. Ten-year results of the Scandinavian sarcoma group protocol SSGIV  

International Nuclear Information System (INIS)

A report on the long-term follow up of the first cooperative Scandinavian Sarcoma Group study in Ewing's sarcoma of bone is presented. Fifty-two previously untreated patients entered the study between 1984 and 1990. Half of the tumors were located in the extremities and one quarter in the pelvis. The combined modality treatment consisted of 5 cycles of chemotherapy - including vincristine, methotrexate, doxorubicin, cyclophosphamide, bleomycin and dactinomycin. The first two cycles were followed by local resection or amputation in 35 patients and by radiotherapy alone in 17 patients. When surgery was not performed, was incomplete or yielded poor margins radiotherapy was given at a dose of 40-60 Gy. Local tumor relapses developed in 10 patients and in all but one patient were accompanied by metastatic disease. Five patients had metastasis at diagnosis and distant metastases developed after primary treatment in 27 patients after a median of 14 ...

475

Daily cone-beam computed tomography used to determine tumour shrinkage and localisation in lung cancer patients  

Energy Technology Data Exchange (ETDEWEB)

Purpose/Objective. Daily Cone-beam computed tomography (CBCT) in room imaging is used to determine tumour shrinkage during a full radiotherapy (RT) course. In addition, relative interfractional tumour and lymph node motion is determined for each RT fraction. Material and methods. From November 2009 to March 2010, 20 consecutive lung cancer patients (14 NSCLC, 6 SCLC) were followed with daily CBCT during RT. The gross tumour volume for lung tumour (GTV-t) was visible in all daily CBCT scans and was delineated at the beginning, at the tenth and the 20th fraction, and at the end of treatment. Whenever visible, the gross tumour volume for lymph nodes (GTV-n) was also delineated. The GTV-t and GTV-n volumes were determined. All patients were setup according to an online bony anatomy match. Retrospectively, matching based on the internal target volume (ITV), the GTV-t or the GTV-n was performed. Results. In eight patients, we observed a significant GTV-t shrinkage ...

2010-10-15

476

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The ...

2003-07-21

477

Comparison of stereotactic radiosurgery and fractionated stereotactic radiotherapy of acoustic neurinomas according to 3-D tumor volume shrinkage and quality of life  

International Nuclear Information System (INIS)

Background and purpose: stereotactic radiosurgery (SRS) and also fractionated stereotactic radiotherapy (SRT) offer high local control (LC) rates (> 90%). This study aimed to evaluate three-dimensional (3-D) tumor volume (TV) shrinkage and to assess quality of life (QoL) after SRS/SRT. Patients and methods: from 1999 to 2005, 35/74 patients were treated with SRS, and 39/74 with SRT. Median age was 60 years. Treatment was delivered by a linear accelerator. Median single dose was 13 Gy (SRS) or 54 Gy (SRT). Patients were followed up ? 12 months after SRS/SRT. LC and toxicity were evaluated by clinical examinations and magnetic resonance imaging. 3-D TV shrinkage was evaluated with the planning system. QoL was assessed using the questionnaire Short Form-36. Results: Median follow-up was 50/36 months (SRS/SRT). Actuarial 5-year freedom from progression/overall survival was 88.1%/100% (SRS), and 87.5%/87.2% (SRT). TV shrinkage was 15.1%/40.7% (SRS/SRT; p = 0.01). ...

2009-09-01

478

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases  

International Nuclear Information System (INIS)

This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with ?4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10?20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a contrast-enhanced brain CT was reviewed. ...

2009-09-01

479

Combined chemotherapy and radiotherapy: from biology to bed-side  

International Nuclear Information System (INIS)

Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle redistribution. In clinical ...

480

Clinical utility of serum ferritin levels in patients with malignant tumors treated by radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for ...

1983-10-01

481

Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup  

International Nuclear Information System (INIS)

Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any ...

2009-02-01

482

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

International Nuclear Information System (INIS)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT investigations were planned to ...

2005-03-01

483

An iterative filtered backprojection inverse treatment planning algorithm for tomotherapy  

International Nuclear Information System (INIS)

Purpose: An inverse treatment planning algorithm for tomotherapy is described. Methods and Materials: The algorithm iteratively computes a set of nonnegative beam intensity profiles that minimizes the least-squares residual dose defined in the target and selected normal tissue regions of interest. At each iteration the residual dose distribution is transformed into a set of residual beam profiles using an inversion method derived from filtered backprojection image reconstruction theory. These 'residual' profiles are used to correct the current beam profile estimates resulting in new profile estimates. Adaptive filtering is incorporated into the inversion model so that the gross structure of the dose distribution is optimized during initial iterations of the algorithm, and the fine structure corresponding to edges is obtained at later iterations. A three dimensional, kernel based, convolution/superposition dose model is used to compute dose during each iteration. Results: Two clinically ...

1995-07-15

484

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift of 5 mm or more to ...

2010-10-15

485

A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy  

International Nuclear Information System (INIS)

Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information. Conclusions: ...

2006-06-01

486

Symptom experiences during chemotherapy treatment-With focus on nausea and vomiting  

British Library Electronic Table of Contents (United Kingdom)

ZusammenfassungUbelkeit und Erbrechen stellen zwei Symptome dar, die grundlich untersucht worden sind und bei Krebspatienten haufig auftreten. Die meisten Studien haben sich bislang mit Haufigkeit und Management dieser beiden Symptome befasst. Das Ziel dieser Studie bestand darin, ein besseres Verstandnis dafur zu entwickeln, wie Krebspatienten ihre Symptome erleben-insbesondere Ubelkeit und Erbrechen nach Chemotherapie-und welche Auswirkungen diese Symptome auf den Tagesablauf der Patienten haben. Neun Frauen mit unterschiedlichen Krebsleiden und Chemotherapie Regimes wurden zwecks Chemotherapie stationar aufgenommen und nahmen an der Studie teil. Es wurden halbstrukturierte Interviews einschliesslich einer Inhaltsanalyse in Anlehnung an Kvale durchgefuhrt (Klarung und Entwicklung neuer B...

2006-01-01

487

Supporting Children-s Social and Emotional Well-being: Does -Having a Say- Matter?  

British Library Electronic Table of Contents (United Kingdom)

This article argues the importance of ensuring initiatives aimed at improving children-s social and emotional well-being are based on sound participatory principles. The discussion posits links between the recognition of children, dialogic approaches to participation, changing conceptualisations of children and childhood, and children-s well-being. It explores these links in light of one particular initiative, Seasons for Growth (Graham, 1996, 2002, Seasons for Growth; Loss and Grief Education Program. MacKillop Foundation), an education programme built around emerging evidence that giving children a voice assists them to adapt to family change. The paper concludes with insights into what is involved when we locate notions of -having a say- as a key element in promoting children-s well-bei...

2011-01-01

488

Superselective intra-arterial DSA in patients with femoral head necrosis and femoral neck fracture. Superselektive intraarterielle DSA bei Hueftkopfnekrose und Schenkelhalsfraktur  

Energy Technology Data Exchange (ETDEWEB)

The prospective study includes 25 patients without pathology of the femoral head for the evaluation of the normal femoral head perfusion. In addition 34 patients with femoral head necrosis underwent i.a. DSA preoperatively before pedicled pelvic bone grafting. 15 patients after pelvic bone graft operation and 7 patients with medial femoral head fracture were also examined via superselective DSA. In cases with femoral head necrosis a rarefaction or interruption of the rami nutricii proximales, or an occlusion of the medial circumflex femoral artery were observed. Patients with medial femoral neck fracture showed an interruption of the rami nutricii proximales of the femoral head. Postoperative DSA - after pedicled pelvic bone graft - revealed a regular arterial graft perfusion in 82%. (orig.).

1991-06-01

489

Stentgraftimplantationen im Aortenbogen  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Hintergrund Endograftimplantationen im oder am Aortenbogen stellen besondere Herausforderungen an die Implantationstechnik und an die mechanischen Eigenschaften von Stentgrafts und ihren Einf?hrungssystemen, bedingt durch die Notwendigkeit, die Prothesen punktgenau abzusetzen und durch die mit der Biegung im Aortenbogen zunehmende Reibungswiderst?nde innerhalb der Einf?hrungssysteme. Die Endograftsysteme der 1. Generation (Talent?, Zenith TX 1?, TAG?) zeigten in dieser Lokalisation technisch bedingte Limitationen. Neue Prothesen Bei den seit 2004 und 2005 verf?gbaren neuen Stentgrafts (E-vita?, Zenith TX 2?, Valiant?, Relay?) sind diese Limitationen weitgehend ?berwunden. Durch technische Verbesserungen von Stentgrafts und Einf?hrungssystemen ist es nun m?glich, auch lange ...

2006-01-01

490

Investigations of methane emissions from civil water wells on the Bentheim-Salzbergen ridge near Schuettorf; Untersuchungen von Methangasaustritten aus zivilen Brunnenbohrungen im Bereich des Bentheim-Salzbergener Sattels bei Schuettorf  

Energy Technology Data Exchange (ETDEWEB)

In a water well sunk in the Grafschaft Bentheim region of northern Germany, small volumes of methane were emitted regularly and large volumes of methane in eruptions at irregular intervals. After some extreme gas eruptions in 2002 and 2004, the Grafschaft Bentheim district government initiated a project to investigate underground conditions in the region between Nordhorn and Bad Bentheim in order to prevent potential hazards to the locals population. The main purpose of the project was to provide information on underground mechanisms as far as possible in order to develop long-term safety strategies for freshwater supply in the region. (orig.)

2007-09-13

491

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

492

Influence of condensers of the chemical process of the water/steam cycle; Einfluesse von Kondensatoren auf die Chemie des Wasser-/Dampfkreislaufes  

Energy Technology Data Exchange (ETDEWEB)

Apart from condensing the off-air condensers have a number of additional functions, which have been added more or less incidentally as development progressed. Advanced development of certain types of turbine condensers justifies the hope that these additional functions can be improved as power plants become cheaper and simpler.(orig.) [German] Kondensatoren haben neben ihrer Hauptaufgabe, der Kondensation des Turbinenabdampfes eine Reihe zusaetzlicher Funktionen, die sich z.T. im Laufe der Entwicklung eher beilaeufig ergeben haben. Der hohe Entwicklungsstand bei bestimmten Bauarten von Turbinenkondensatoren laesst die Erwartung zu, dass im Zuge der Vereinfachung und Verbilligung von Kraftwerksanlagen 'Nebenfunktionen' verbessert werden koennen. (orig.)

1998-07-01

493

Functional imaging of neurocognitive dysfunction in attention deficit hyperactivity disorder; Bildgebende Darstellung neurokognitiver Dysfunktionen bei der Aufmerksamkeitsdefizit-/Hyperaktivitaetsstoerung  

Energy Technology Data Exchange (ETDEWEB)

Attention Deficit Hyperactivity Disorder (ADHD) is a neurobiological disorder of early childhood onset. Defining symptoms are chronic impairments of attention, impulse control and motor hyperactivity that frequently persist until adulthood. Miscellaneous causes of the disorder have been discussed. Accumulating evidence from imaging- and molecular genetic studies strengthened the theory of ADHS being a predominantly inherited disorder of neurobiological origin. In the last 15 years, non-invasive brain imaging methods were successfully implemented in pediatric research. Functional magnetic resonance imaging studies gave major insight into the neurobiological correlates of executive malfunction, inhibitory deficits and psychomotoric soft signs. These findings are in good accordance with brain morphometric data indicating a significant volumetric decrease of major components of striato-thalamo-cortical feedback loops, primarily influencing prefrontal executive functioning (e.g. basal ...

2005-02-01

494

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

495

Die Einstellung von Simulated-Moving-Bed-Anlagen mit Hilfe des Coherence-Konzepts  

British Library Electronic Table of Contents (United Kingdom)

Fur die Trennung binarer Gemische wird zunehmend das Simulated Moving Bed (SMB)-Verfahren verwendet. Fur einen storungsfreien Betrieb mussen die Volumenstrome sowie die Umschaltzeit exakt eingestellt werden. In diesem Beitrag wird mit Hilfe des Coherence-Konzepts eine Methode aufgezeigt, mit der sich die Stellgroen fur einen dispersionsfreien SMB-Prozess bestimmen lassen. Fur Langmuir- und Anti-Langmuir-Isotherme konnen einfache explizite Gleichungen bei vollstandiger Trennung angegeben werden. Das Grundprinzip dieser Methode lasst sich auch auf andere Isotherme sowie fur die unvollstandige Trennung ubertragen.

2009-01-01

496

Burning ice. Methane hydrate on the sea floor; Brennendes Eis. Methanhydrat am Meeresgrund  

Energy Technology Data Exchange (ETDEWEB)

In certain regions of the sea floor, water and methane from organic depositions have turned into a burnable form of ice, i.e. methane hydrates which contain more stored energy than all fossil fuel reserves. If they should desintegrate as a result of global heating, methane will be released and will contribute to further global heating. [Deutsch] Im Boden bestimmter Meeresregionen haben sich Wasser und Methan aus organischen Ablagerungen zu einer brennbaren Form von Eis vereinigt. Diese Methanhydrate speichern mehr Energie als alle fossilen Brennstoffvorraete. Wenn sie sich bei einer globalen Erwaermung zersetzen, koennte das entweichende Methan als Treibhausgas die Erde noch mehr aufheizen. (orig.)

1999-06-01

497

25. lecture meeting 'Long-term performance of heat-resistant steels and high-temperature materials'. Proceedings; 25. Vortragsveranstaltung 'Langzeitverhalten warmfester Staehle und Hochtemperaturwerkstoffe'. Beitraege  

Energy Technology Data Exchange (ETDEWEB)

The following subjects were discussed at the conference: Stability of welded joints, creep stress in CrMo steels, life prediction, developments in modern power plant steels, testing, calculation of deformation, crack propagation and crack analysis under complex loads. [German] Die Autoren der Tagung referieren ueber folgende Themen: Stabilitaet von Schweissverbindungen, Kriechbeanspruchung von Chrom-Molybdaen Staehlen, Lebensdauervorhersage, Entwicklungen fuer die Anwendung in modernen Kraftwerken, Prueftechnik, Berechnung von Verformung, Rissentwicklung und -bewertung bei komplexer Beanspruchung. (uke)

2002-07-01

498

Updating a system concept of water pollution abatement measures against oil and other pollutants that contaminate the German waterways; Fortschreibung des Systemkonzeptes ueber Massnahmen zur Bekaempfung von Oel und anderen Schadstoffen auf dem Wasser im Bereich der Bundesrepublik Deutschland  

Energy Technology Data Exchange (ETDEWEB)

This update of a system concept entitled ``Maritime hazard prevention and water protection`` makes full use of the technical room for maneuver while considering that reasonable financial and economic conditions must be provided. The update allows on to continue or start the exploitation of feasible technical, logistic and information-technology development potentials. The same applies to the national maritime traffic safety measures developed for the German waterways. Considering the maritime hazards that have been prevailing in the coastal areas of the German North Sea, the conducted damage risk investigations suggest that a large-scale, disastrous oil contamination of the mud flats ecosystem cannot be excluded or controlled definitely in spite of the numerous measures taken. (orig.) [Deutsch] Mit der vorgelegten Fortschreibung zum Systemkonzept ``Gefahrenabwehr und Gewaesserschutz im Seeverkehr`` werden die technisch realisierten Handlungsspielraeume unter Beachtung der finanziellen ...

1994-04-01

499

Radiological protection. Textbook for radiographers and reference book for radiological safety officers; Strahlenschutz. Lehrbuch fuer Personen, die nach den Bestimmungen der Roentgenverordnung vom 8. Januar 1987 als medizinisch-technische Radiologieassistenten taetig sind und zur Unterweisung fuer Strahlenschutzbeauftragte  

Energy Technology Data Exchange (ETDEWEB)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe) [Deutsch] Das vorliegende Lehrbuch, das sich vor allem an das technische Personal und an Strahlenschutzbeauftragte wendet, unterrichtet ueber die derzeit gueltigen Bestimmungen der Roentgenverordnung, die Anwendung von Roentgenstrahlen, ueber Qualitaetssicherung, die Organisation der Filmverarbeitung sowie ueber die Anforderungen an die Qualitaet von Roentgenbildern. Im ...

1996-12-31