Neutralizing an acidic fluid consists of adding a sodium hydroxide solution to neutralize the H group of acids, therefore increasing the pH. The injection of sodium hydroxide has to be continuous and at a proper depth inside the well to protect against the corrosion of casing and surface equipment. Neutralization is a common practice used in geothermal fields, such as at The Geysers in the US and Miravalles in Costa Rica-places where aggressive fluids cause problems for extracting and using geothermal fluids commercially. A zone surrounding wells H-4, H-16 and H-29 in the northern section of the Los Humeros, Pue., geothermal field, known as the Colapso Central, has shown evidence of aggressively acidic fluids. Several wells drilled in the area had to be repaired, thus plugging and isolating the deepest production zones. Well H-43 was drilled two years ago in the northern zone of the field, and even though it is not located in the aggressive-fluid zone, the well presents mineralogical ...