Self-expanding metallic stent insertion has been widely applied for the palliative treatment of malignant esophageal strictures. Although it is known as an easy, safe, and effective procedure, complications are well known and include things such as stent migration and esophageal stent occlusion caused by tumor in growth. However, metallic stent fractures have been rarely reported in the esophagus, especially for nitinol stents. We report a case of a stent fracture associated with migration in a patient with a malignant esophageal stricture near the gastroesophageal junction. It is highly probable that the stent fracture was due to chemical erosion of the stent caused by gastric juice
BackgroundThere is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was...Full Text Available
We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric ...
Background: Mechanisms underlying the association between myocardial bridge (MB)-stenting and in-stent restenosis (ISR) are still unclear. Objective: To assess the impact of MB on ISR using intravascular ultrasound (IVUS). Methods: In the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, 100 left anterior descending artery (LAD) culprit lesions (79 treated with paclitaxel-eluting stents [PES] and 21 treated with bare metal stents) were imaged with serial IVUS immediately postprocedure and at 13 months. Results: At baseline the LAD stent extended into the MB segment beyond the culprit lesion in seven patients (MB-stent group). In the remaining 93 patients the LAD stent was implanted only in the culprit lesion without extending into t...
Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen ...
Nitinol has found growing applications in vascular stents, with the recent introduction on the market of a number of new nitinol tubular devices for coronary and peripheral usage. These stents can be produced either through the expansion of a pattern cut on a small tube (pre-cut) or by cutting the deployed design on a tube of a larger size (pre-expanded). The aim of the study was to analyze the differences of properties induced by the two manufacturing methods. For this purpose, differential scanning calorimetry (DSC) measurements were performed on various specimens from the two types of stents. A first set of measurements shows that pre-expanded stents exhibit usual A<->R<->M transformations whereas multi-stage transformations occur for pre-cut stents. Two types of DSC specimens were then prepared for each stent, corresponding to the ...
BackgroundVascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either...Full Text Available
ObjectivesWe undertook a meta-analysis to assess outcomes for drug-eluting (DES) and bare metal stents (BMS) in percutaneous coronary intervention (PCI) for unprotected...Full Text Available
AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer.METHODS: The new stent is composed...Full Text Available
Despite advances in polymer and drug technology, the underlying stent platform remains a key determinant of clinical outcome. A clear understanding of stent design and the differences between various stent platforms are of increasing importance for the interventional cardiologist. Reduction in stent strut thickness has been associated with improved stent deliverability, improved procedural outcome, and lower rates of subsequent restenosis. Newer-generation 316L-SS stent designs have enabled reduced strut thickness while retaining radial strength and minimizing recoil, but with significant loss of radiopacity, leading to reduced visibility. Cobalt chromium alloys have enabled a reduction in stent strut thickness to around 80?90 mm while retaining modest radiopacity, but due to higher elasti...
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter ...
The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of ...
To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median ...
The purpose of this study was to evaluate the safety and the retrievability of a new covered retrievable nitinol tracheobronchial stent. Stents were knitted from 0.2mm nitinol wire, covered with polyurethane, and were 20-22mm in diameter and 2cm in length. Under fluoroscopic guidance, a stent was placed in the normal right bronchus intermedius of ten dogs. Using a retrieval hook, stent retrieval was attempted after 1 month(N=5) or 2 months(N=5). After removal, the dogs were sacrificed and their their tracheobronchial trees were examined grossly and histologically. Eleven stents were successfully placed in ten dogs. Migration and expectoration occurred in four of ten stents in nine dogs(40%). Five stents were successfully removed from six dogs(83%). Without significant difference between the two groups, mild to moderate mucosal hyperplasia ...
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the ...
We wanted to evaluate the long-term results of a dual expandable nitinol stent for the palliative treatment of malignant gastroduodenal strictures. The dual stent consists of two stents; an outer partially nylon covered stent and an inner bare nitinol stent. The outer stent was placed into the stricture and this was followed by coaxial placement of the inner bare stent. Using fluoroscopic guidance, dual expandable stents were placed in 86 patients with inoperable malignant gastroduodenal strictures. The technical and clinical success, the complication, survival and the stent patency were evaluated during the follow-up period. Stent placement was technically successful in 83 of the 86 patients. After stent placement, 74 of the 85 patients showed improvement of ...
Zusammenfassung Hintergrund Endograftimplantationen im oder am Aortenbogen stellen besondere Herausforderungen an die Implantationstechnik und an die mechanischen Eigenschaften von Stentgrafts und ihren Einf?hrungssystemen, bedingt durch die Notwendigkeit, die Prothesen punktgenau abzusetzen und durch die mit der Biegung im Aortenbogen zunehmende Reibungswiderst?nde innerhalb der Einf?hrungssysteme. Die Endograftsysteme der 1. Generation (Talent?, Zenith TX 1?, TAG?) zeigten in dieser Lokalisation technisch bedingte Limitationen. Neue Prothesen Bei den seit 2004 und 2005 verf?gbaren neuen Stentgrafts (E-vita?, Zenith TX 2?, Valiant?, Relay?) sind diese Limitationen weitgehend ?berwunden. Durch technische Verbesserungen von Stentgrafts und Einf?hrungssystemen ist es nun m?glich, auch lange ...
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45/sup 0/ and 90/sup 0/. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10/sup -10/ and 2.6 x 10/sup -10/ cm/sup -2/sr /sup -1/ sec/sup -1/, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10/sup -9/ cm/sup -2/ sr/sup -1/ sec/sup -1/. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45"0 and 90"0. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10"-"1"0 and 2.6 x 10"-"1"0 cm"-"2sr "-"1 sec"-"1, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10"-"9 cm"-"2 sr"-"1 sec"-"1. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
The covered self-expandable metallic stent (SEMS) has been developed to overcome the problem of tissue ingrowth, However, stent migration is a well-known complication of covered...Full Text Available
To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, ...
Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 #+-# 29) #mu#mol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting ...
Biodegradable helicoidal stent prototypes made up of layers of poly-L-lactic acid (PLLA) and poly(L-lactic-co-glycolic acid) (PLGA) polymers were fabricated by temperature conditioning the stents at different stages of fabrication. The process incorporated elastic memory, or self-expandability in the stent, which is desirable to minimize stent recoil. The collapse pressures of such stents were studied, with and without in vitro degradation. The effects of thickness and the composition of each layer on the collapse pressure were modeled using the simple series model. Results of the in vitro studies for over 3 months showed that collapse pressure of the stents depended mainly on the degradation and other side-effects brought about by the degradation of different polymer compositions. General...
On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).
To evaluate the efficacy of a paclitaxel-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt. Twelve pigs were used in this study. Two types of 10-mm diameter and 60-mm long nitinol stents were made for a transjugular intrahepatic portosystemic shunt by coating them with a polyurethane solution, with and without paclitaxel. Each transjugular intrahepatic portosystemic shunt was created successfully in the 12 swine with 7 paclitaxel-eluting stents and 5 polyurethane stents. Five swine in each group were followed-up for 14 days due to the death of 2 swine given the paclitaxel-eluting stents. The proliferation of the pseudointima was evaluated on both follow-up portograms and histopathology examinations. The mean maximum pseudointimal hyperplasia is expressed as the percentage of the stent radius. ...
Purpose: To evaluate the effect on dilatation of three types of covering materials used for endovascular stent-grafts.Methods: Stent-grafts with three types of covering material [0.1-mm polytetrafluoroethylene (PTFE), 0.2-mm PTFE, and 0.15-mm woven polyester] were placed in a fluid circuit. For the pulsatile pressure test, the luminal pressure of 190/130 mmHg was loaded up to 300,000 pulses. For the static pressure test, the luminal pressure was increased from 50 to 300 mmHg at 50-mmHg increments. The percent of dilatation of each stent-graft was compared.Results: The 0.1-mm PTFE stent-graft was significantly more dilated than the 0.2-mm PTFE and the 0.15-mm woven polyester stent-graft (p < 0.005) in both examinations. There was no significant difference between the 0.2-mm PTFE and the 0.15-mm woven polyester stent-grafts. The dilatation of the 0.1-mm PTFE ...
To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm ...
We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the ...
We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. The BD stents need to be loaded into a conventional pull-back delivery system but are then placed in a standard fashion. Pre-dilatation should be avoided to reduce the risk of migration, however if migration occurs the stents can be left to dissolve in the stomach. The stents are radiolucent but easily identified on CT with minimal artefact and thus might even aid with radiotherapy planning. BD stents offer an exciting new strategy for therapy-resistant benign strictures as well as a supportive measure for oesophageal cancer undergoing non-surgical treatment. (orig.)
Objective: To evaluate the feasibility and clinical application of two stents insertion via single tract for treatment of hepatic hilar cholangiocarcinoma. Methods: Eighteen patients with hepatic hilar cholangiocarcinoma who had left and right bile duct obstruction were treated with stents insertion via right bile duct puncturing routeway. These two stents were implanted between right and left bile duct, and between right bile duct and common bile duct. Results: Eighteen patients obtained successful two stents placement by right bile duct puncturing tract and succeeded with internal drainage for all biliary tree jaundice subsided distinctly. Conclusions: The technique of two stents insertion via single tract could predigest interventional drainage procedure of high bile duct obstruction, reduce operation trauma, shorten handling time and possess promising application value
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there ...
Coiling or infusion of embolic materials into a wide necked aneurysm can be performed with stenting. The purpose of our study is to assess the technical feasibility of aneurysm treatment with glue embolization after stenting. We used four Wallstents for surgically repairing eight canine carotid aneurysms. After confirmation of the aneurysms on the angiogram, we introduced a 6-7 F guiding catheter in order to deploy the stents. After stenting, we passed a microcatheter into the aneurysm lumen through the stent mesh. 28% glue was slowly injected until the glue cast completely filled the lumen. We evaluated the passage of a microcatheter through the stent meshwork, formation of the glue cast and the stents' ability to protection for any leakage of glue. The follow-up angiogram was obtained for two dogs, one to three times until 8 weeks, and ...
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
BackgroundAirway complications are among the most challenging problems after lung transplantation, and Self-Expandable Metallic Stents (SEMS) are used to treat airway complications...Full Text Available
AIM: To evaluate the efficacy of self expandable metallic stents (SEMS) in patients with malignant esophageal obstruction and fistulas.METHODS: SEMS were implanted in the presence of fluoroscopic...Full Text Available
Purpose:To evaluate the midterm efficacy and safety of the iStent® glaucoma device in patients with secondary open-angle glaucoma.Patients...Full Text Available
Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' ...
Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where...Full Text Available
AIM: To compare 2 different types of covered esophageal nitinol stents (Ultraflex and Choostent) in terms of efficacy, complications, and long-term outcome.METHODS: A retrospective review of...Full Text Available
Background and ObjectivesClopidogrel resistance or low-responsiveness may be associated with recurrent atherothrombotic events after drug-eluting stent (DES) implantation. We prospectively...Full Text Available
The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early ...
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues ...
Radiotherapy has been reported to be of benefit in prolonging the survival of patients with cholangiocarcinoma. This study examined whether radiotherapy in addition to endoscopic stenting improved survival. The survival advantage of radiotherapy in those with a type II/III stricture is seen only in the first 10 months after diagnosis. The costs of radiotherapy and significantly increased time spent in hospital, however, raise doubts over its routine use in the management of non-resectable cholangiocarcinoma. (Author).
BackgroundPaclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation...Full Text Available
When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) ...
The mechanical stability of diamond-like carbon (DLC) films coated on nitinol vascular stents was investigated under cyclic loading condition by employing a stent crimping system. DLC films were coated on the vascular stent of a three dimensional structure by using a hybrid ion beam system with rotating jig. The cracking or delamination of the DLC coating occurred dominantly near the hinge connecting the V-shaped segments of the stent where the maximum strain was induced by a cyclic loading of contraction and extension. However the failures were significantly suppressed as the amorphous Si (a-Si) buffer layer thickness increased. Interfacial adhesion strength was estimated from the spalled crack size in the DLC coating for various values of the a-Si buffer layer thickness.
Objective: To explore the interventional treatment for biliary re-stenosis after metallic stents placement in patients due to cholangiocarcinoma and evaluate its therapeutic effect. Methods: Percutaneous metallic stents placement or combined with continuously infusion arterial chemotherapeutic and chemotherapeutic embolization were performed in 12 patients with biliary re-stenosis using 12 metallic stents. Results: Once stent placement was 100% successful in all 12 cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that in preoperation. Jaundice was reduced satisfactorily in 12 patients. 3 patients were undergone continuously arterial chemotherapeutics infusion and chemotherapeutic embolization 4 weeks after stents placement. Conclusions: Percutaneous replacement of biliary metallic stents was effective and safe for ...
Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and ...
Objective: To evaluate the clinical efficacy of multiple stents placement in the management of hilar cholangiocarcinoma, especially in the complex cases of which the hepatic ducts are invaded. Methods: Forty-five consecutive patients with hilar cholangiocarcinoma were treated with percutaneous transhepatic placement of two or three self-expandable metallic endoprostheses. The cause of hilar obstructions in these patients were all cholangiocarcinoma, including Bismuth classification type II (n 12), IIIa (n 17), IIIb (n 10), and IV (n 6). Two or 3 stents were placed in the configuration of T, Y or X over the strictures. Results: Stent placement with 2 or 3 endoprostheses was successful in all patients. All patients showed significant decrease in serum bilirubin level. The mortality rate within 30 days of stent placement was 2.2% (1/45). The mean survival and stent patency times were ...
To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse ...
Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further ...
Purpose: The lifelong persistence of foreign bodies within the arteries may contribute to restenosis. Thus,biodegradable devices might decrease recurrence rates. Methods: Eleven polyhydroxybutyrate biodegradable stents and 13 tantalum stents were implanted into the iliac arteries of New Zealand white rabbits for up to 30 weeks. After killing the animals,the specimens were harvested, fixed in formalin, processed in paraffin,and stained. Results: Polyhydroxybutyrate instigated intense inflammatory and proliferative reactions with an increase in collagen (2.4- to 8-fold vs native segments), thrombosis and in-stentlumen narrowing (375.5-606.6 mm vs 655.6 #+-# 268.8 mm in native segments). The elastic membranes were destroyed in all specimens. The tantalum stents increased the in-stent lumen progressively (769.7 #+-# 366.6 mm vs 1309.9 #+-# 695.3 mm),penetrated the external elastic membrane, and increased ...
The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous ...
To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of ...
We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were ...
Stenting for stenosis of the proximal vertebral artery (VA) is commonly performed via a femoral approach. However, iliofemoral occlusive disease such as arteriosclerosis obliterans sometimes prevents safe transfemoral access. In certain situations where both femoral access and ipsilateral brachial access are difficult because of a concomitant vascular diseases or particular anatomic setting, a contralateral brachial approach using the brachiobrachial pull-through technique may allow efficient and accurate stenting. A case of VA origin symptomatic stenosis successfully treated with stenting using the new pull-through technique from the contralateral brachial artery to the brachial artery on the affected side is described. (orig.)
VHF wind-profiling radars often measure a decrease of echo power with zenith angle, which can be explained from in situ measurements of horizontal layering or anisotropy of metre-scale temperature structure in the atmosphere. There can also be an azimuthal variation of echo power, which is increased in an azimuth opposite to the vertical shear vector of horizontal wind. This paper checks if the azimuth variation can also be linked to in situ observations of temperature structure, using aircraft flights in the tropopause region near a VHF radar. At heights where VHF radar measures wind shear and aspect sensitivity, there can be an asymmetry in the probability distribution of horizontal gradient of potential temperature, for horizontal scale of e.g. hundreds of metres. The asymmetry is often...
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and ...
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures ...
ObjectiveWe wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients.Materials...Full Text Available
Background. New-generation drug-eluting stents (DES) may solve several problems encountered with first-generation DES, but there is a lack of prospective head-to-head comparisons between...Full Text Available
Purpose: To evaluate the initial and mid-term results of a new self-expanding low strut profile nitinol stent for treatment of atherosclerotic lesions stenoses and occlusions in the superficial femoral artery (SFA). Materials and Methods: In 8 patients (4 male, 4 female, mean age 74.8 {+-} 8.8 years) with SFA lesions and non-satisfying results after PTA treatment alone, 10 self-expanding nitinol Xpert stents were deployed via a 4 F sheath. Stent characteristics and handling were graded by the interventionalist. Fontaine classification, duplex flow measurements and ankle brachial index (ABI) at rest and stress were taken prior and one day after stent placement. Patients were followed 3, 6 and 12 months after the procedure obtaining the same parameters at each appointment. Results: Initial stent treatment was successful in all patients. Stent handling and ...
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich ...
BACKGROUNDSeveral carotid endarterectomy (CEA) randomized controlled trials (RCTs) and series have reported higher perioperative stroke and death rates for women...Full Text Available
Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an ...
The endovascular treatment of atherosclerotic intracranial arterial stenoses has previously been based on balloon dilatation or the deployment of a balloon expandable stent. Both methods have advantages (balloon: flexibility; balloon expandable stent: high radial force) and drawbacks (balloon: risk of elastic recoil and dissection; balloon expandable stent: limited flexibility, risk of injury to the vessel due to excessive straightening, overexpansion at ends of stent). A new combination of balloon dilatation, followed by the deployment of a self-expanding microstent has been applied in 15 patients with atherosclerotic arterial stenoses, symptomatic despite medical treatment. An anatomically and clinically adequate result was achieved in all patients. The initial degree of stenosis was 72% (mean). Balloon dilatation resulted in an average residual stenosis of 54% (mean), reduced further to a mean of 38% ...
Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored ...
Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment offers and improvement ...
Background This study aimed to evaluate the feasibility, safety, and follow-up results of endoscopic papilletomy (ESP) with pancreatic and biliary duct stent placement for ampullary tumors. The therapeutic approach to benign ampullary tumors remains unsettled. The ESP procedure is a curative treatment option for benign papillary tumors, but ESP raises concerns about a relatively high risk for procedure-related complications such as pancreatitis. A pancreatic stent may protect against complications. Methods Between September 2000 and June 2008, 36 patients with ampullary tumors confined to the mucosa and no intraductal tumor growth underwent ESP. The preprocedural diagnostic tools included endoscopic ultrasound, transpapillary intraductal ultrasound, and endoscopic retrograde cholangiopancr...
PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...
The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the ...
A ten week old girl who had previously undergone a palliative procedure for the hypoplastic left heart syndrome had unrelieved aortic coarctation that did not respond to standard balloon dilatation....Full Text Available
Leakage after oesophageal anastomosis or perforation remains a challenge for the surgeon. Traditional management has been operative repair or intensive conservative management. Both treatments are...Full Text Available
Background:Endothelin-1 may be involved in the development of diabetic microangiopathy. We studied the effect of endothelin-1 blockade on myocardial microcirculation during coronary...Full Text Available
Incidence of esophageal cancer (EC) is rising more rapidly in the Western world than that of any other cancer. Despite advances in therapy, more than 50% of patients have incurable disease at the time...Full Text Available
Aneurysms of saphenous vein grafts are rare but can result in complications such as myocardial infarction or death. Percutaneous treatment has included a variety of approaches, including covered stents....Full Text Available
Gastrointestinal perforations are conservatively managed at endoscopy by through-the-scope endoclips and covered self expandable stents, according to the size and tissue features of the perforation....Full Text Available
Recurrent tumour after radical pancreaticoduodenectomy may cause obstruction of the small bowel loop draining the liver. Roux-loop obstruction presents a particular therapeutic challenge, since the...Full Text Available
BackgroundObservational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic...Full Text Available
Photodynamic therapy (PDT) is an established endoscopic technique for ablating Barrett’s esophagus with high-grade dysplasia or early-stage intraepithelial neoplasia. The most common clinically...Full Text Available
Endovascular treatment of post-traumatic pseudoaneurysms has become a viable, less invasive option when compared to open repair. Due to the relative youth of this technology, studies have yet to be...Full Text Available
A 57-year-old man with a history of coronary artery disease and placement of an implantable cardioverter-defibrillator presented at our emergency room with an anterior ST-elevation myocardial infarction....Full Text Available
Tracheobronchial balloon dilation and stent placement have been well used in the treatment of patients with benign and/or malignant diseases. Balloon dilation is the first option in the treatment of...Full Text Available
Pseudoaneurysms related to the superior mesenteric artery (SMA) are a recognised complication of trauma to the vessel, and successful treatment with stenting has been previously described. We report...Full Text Available
Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents....Full Text Available
IntroductionIntrarenal pseudoaneurysm is a rare, yet clinically significant, complication of percutaneous nephrolithotomy. A high index of clinical suspicion is necessary in order...Full Text Available
Hemoptysis in patients with lung cancer is not uncommon and sometimes have dangerous consequences. Hemoptysis has been managed with various treatment options other than surgery and medicine, such as...Full Text Available
IntroductionFlow diversion is a new approach to the endovascular treatment of intracranial aneurysms which uses a high density mesh stent to induce sac thrombosis. These devices...Full Text Available
ObjectiveTo determine if an aggressive approach to coronary revascularisation with oversized balloons is counterproductive, we studied the effect of increasing balloon‐to‐artery...Full Text Available
Carotid artery stenosis is a major risk factor for stroke, and treatments for this condition to decrease the risk of stroke include medical therapy, carotid endarterectomy (CEA), and, more recently,...Full Text Available
Objective: To determine the efficacy of a covered stent prototype designed for protected carotid angioplasty to reduce cerebral embolization. Material and Method: The covered stent tested is made of nitinol, coated with a polyurethane membrane (MembraX{sup TM}; porous size 80 {mu}m). In a bench-top model (flow-rate 650 ml/min, pulsatile flow [dicrote] 123 Pulses/min, pressure 100/60 mm Hg [mean pressure 80 mmHg]) with inserted human carotid (n=6) stent implantation was performed (8/32 mm). Passed particles (mg) were determined in the effluent of a 100 {mu}m filter prior to intervention, after stent deployment and after final dilation (5 mm). Results: When stenting carotid arteries obtained from human cadavers, the highest rate of particle embolization was measured while crossing the lesion with the delivery device (6,8 mg; for all p<0,05), embolization after additional ...
Abstract Introduction: The obstructed, infected kidney is a urological emergency. It has been accepted that the management of infected hydronephrosis secondary to ureteric stones is through prompt decompression of the collecting system. However, the optimal method of decompression has yet to be established. Materials and Methods: A PubMed and Medline search was performed of all English-language articles from 1960 using key words ?sepsis,?? ?urosepsis,?? ?obstruction,?? ?obstructive pyelonephritis,?? ?pyonephrosis,?? ?infection and hydronephrosis?? ?decompression,?? ?stent,?? ?nephrostomy,?? and ?management.?? The Cochrane database and National Institute for Clinical Effectiveness guidelines were searched using the terms ?sepsis,?? ?urosepsis,?? ?stent,?? ?nephrostomy,?? or ?obstruction.?? ...
The purpose of this study was to investigate the feasibility and the optimal conditions of radiofrequency (RF) ablation by using the stent-type electrode upon the saphenous vein of goats for the endovenous treatment of varicose veins. A self-expandable nitinol stent electrode (6 mm diameter, 2 cm length, cell size; 1.3 x 2 mm) was designed to expose the distal 1 cm segment to allow for contact with the venous wall. The proximal part of the electrode was connected to the RF generator by insulated copper wires located within the stent electrode introducer. Initially, to optimize the power setting, ablation of 6 saphenous veins in 3 goats was performed with power settings of 10, 20 and 30 W. Pull back rate of the electrode was 2 and 4 cm/min for each power level, respectively. The goats were sacrificed 4-6 weeks later and histologic examinations of the saphenous veins were done. For the second part of the experiment, RF ...
Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure ...
We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed ...
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities have become a part of international activities, especially the EU Environment and Climate Programme`s ...
Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with ...
Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the ...
To assess the technical feasibility of a newly designed stent-like electrode in rabbits. A stent-like electrode was knitted from a single thread of nitinol wire and interconnected to a generator using similar wire. In order to gauge the extent of radiofrequency ablation (RFA), we measured the depth of the ablated area in cow liver using a combination of 180-sec time intervals and 20- watt power increments. For data processing, Cox regression analysis was used. RFA was also applied to the small intestine of rabbits using this stent-like electrode under six different sets of conditions: 10 watts for 1 min, 10 watts for 2 mins, 20 watts for 1 min, 20 watts for 2 mins, 30 watts for 1 min, and 30 watts for 2 mins. To determine the gross and microscopic findings, six animals were sacrificed immediately after the procedure and the results obtained under the different sets of conditions were correlated. Eight rabbits were monitored ...
ObjectivesThe SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. BackgroundPrevious pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. MethodsThe SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a referenc...
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first publication the design of spiral ...
PurposeWe objectively quantified the gain in urethral diameter and the effect of stenting after tubularized incised plate urethroplasty in a rabbit hypospadias model. Materials and MethodsWe created a hypospadias model in 12 New Zealand white male rabbits by excising the ventral urethra. A 3 cm tattoo line was made longitudinally in the dorsal urethral plate midline. Two weeks later a 2 cm relaxing incision was made in the middle part of the tattooed line. The stretched incision width between the tattooed edges was measured, followed by urethral plate tubularization. Six rabbits were stented and 6 were nonstented. Two weeks later the animals were sacrificed and the distance separating the tattoo was measured at the midpoint of the tattooed line. Transverse sections at this point were exami...
BackgroundAlthough self-expandable metal stent (SEMS) insertion is widely used for relief of malignant colorectal obstructions, the immediate technical and clinical failure rates of SEMSs and the associated risk factors remain largely unknown. ObjectiveTo identify rates and factors predictive of technical and clinical failure of SEMSs when their use is attempted for the decompression of malignant colorectal obstruction. DesignRetrospective chart review. SettingA tertiary-care academic medical center in South Korea. PatientsThis study involved a total of 412 patients with malignant colorectal obstruction in whom SEMS insertion was attempted. InterventionPlacement of colonic SEMSs. Main Outcome MeasurementsTechnical success and immediate and long-term clinical success rates. ResultsTechnical...
A 21-year-old woman developed midesophageal stricture two weeks after ingestion of aluminium phosphide (AlP) tablets. Aluminium phosphide is a lethal protoplasmic toxin and is also the most common cause of suicidal poisoning in northern India. Upper gastrointestinal endoscopy (UGIE) showed a tight esophageal stricture 29?cm from the incisors with a circumferential ulcer. Dilatation up to 17?mm was done using Savary-Gilliard dilators. She had repeated dilatations three times at nearly two-week intervals. In view of the resistant stricture, a silicone Polyflex stent was placed across the stricture and removed after 3?months; there was no recurrence of stricture even after three months of follow-up. Patients with recurrent esophageal stricture and those with fistula may benefit from silicone ...
To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) and stent insertion in central venous steno-occlusion. Between August 1992 and January 1998, 11 patients with symptomatic central venous steno-occlusion (six stenoses and five occlusions) underwent pereutaneous treatment. Eleven PTAs were performed and stents were introduced in two patients because of incomplete PTA. During follow-up, a total of eight revisions were performed in five patients with recurrence (six stenoses and two occlusions). Success and long term patency rates were evaluated. The length and degree of the lesion and degree of residual stenosis, as well as pressure gradient through the lesion and decrease of the gradient after PTA, were correlated with patency rates. Complications during the procedures and follow-up period were evaluated. The overall success rate was 89.5%;those of primary and revision intervention were 90. 9% and 87.5%, respectively. ...
Since November 1971, the cosmic ray neutron intensity has been measured continuously with 3NM-64 neutron monitor at Fukushima University (140"029'E geographic longitude, 37"045'N geographic latitude, 27.6"0N geomagnetic latitude and 10.55 GV cut-off rigidity). After the neutron monitor had been operated during the period of fourteen months at the ground floor of 3-storied ferro-reinforced concrete building, it was removed to the prefabricated house near the old position of the monitor at January 1973. As a result of the removement of the monitor, the expected values for the counting rate and barometric coefficient of our neutron monitor were obtained, 7.5x10"4 cph and -0.64% mb respectively. The monitor was moved out into a new place, the statistical accuracy of counting rate is altered from 0.44% (hourly counting rate) to 0.36%. It can be considered that there is no effect of concrete building near the monitor, for reason that the zenith angle is opened more than ...
To understand the effect of heat treatment and mechanical polishing of a Nitinol wire on the chemical composition and physical morphology of the wire surface. Stents with a diameter of 1.0 cm, length of 8-10 cm, and composed of a Nitinol wire, were heat-treated at 500 .deg. C for 30 minutes, and mechanically polished with walnut shell granules. The wire surface morphology was studied with both an optical and a scanning electron microscope (SEM). In addition, an elemental analysis was performed by Energy Dispersive X-ray spectroscopy (EDX). Long microcracks along the wire direction and short microcracks across the wire were observed by SEM from the raw Nitinol wire. Upon heat treatment, the color of the wire turned blue, and Na, K, Cl, Si, Al atoms were seen from the EDX of the heat treated wire, which were absent in the original wire. The microcracks disappeared with the mechanical polishing, and the Na, K, Cl, Si, Al atoms all disappeared after the mechanical ...
Intracranial atherosclerosis is a major cause of ischemic stroke, and depending on the studied population, it accounts for 8%-15% of all strokes that are due to cerebral atherosclerosis. The prognosis of patients with symptomatic intracranial stenoses seems to depend on the location and extent of intracranial atherosclerosis. Currently, the primary treatment in intracranial atherosclerosis is the control of vascular risk factors such as hypertension, diabetes, hypercholesterolemia, and smoking. Secondary prevention with antiplatelet therapy has been shown to reduce the risk of subsequent vascular events in patients who have suffered a recent ischemic stroke or transient ischemic attack (TIA). Unfortunately, a significant number of patients with intracranial atherosclerosis continue to suffer from repeated strokes or TIA despite maximal medical treatment. Although endovascular revascularization for symptomatic intracranial stenoses remains at the investigational stage and much of the ...
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...
Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) ...
Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic ...
BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: ...
Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, with grains smaller than any available ...
Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). The average number of ...
Recently, the development of shape memory alloy (SMA) actuators, in the forms of wire, thin film and stent have been found increasingly in the fields of materials science and smart structures and engineering. The increase in attraction for using these materials is due to their many unique materials, mechanical, thermal and thermal-mechanical properties, which in turn, evolve their subsequent shape memory, pseudo-elasticity and super-elasticity properties. In this paper, a common type of SMA actuator, Nitinol wires, were embedded into advanced composite structures to modulate the structural dynamic responses, in terms of natural frequency and damping ratio by using its shape memory and pseudo-elastic properties. A simple theoretical model is introduced to estimate the natural frequency of the structures before and after actuating the embedded SMA wires. The damping ratios of different SMA composite beams were measured through experimental approaches. The natural ...
Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...
RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} ...
To determine the effectiveness and patency of percutaneous intervention in insufficient native arteriovenous hemodialysis fistulae (AVFs). Between March 1997 and September 2001, 67 cases of insufficient native AVFs resulted from central vein lesion, PTA was performed in 48 cases, and thrombolytic therapy with or without PTA in 11. In eight of the cases, in which central vein stenosis had led to the insufficency, percutaneous transluminal angioplasty (PTA) was performed, and in three of the eight, a stent was inserted. Angiography findings and complications, as well as success and patency rates in the non-thrombosis and thrombosis group, were evaluated; the central vein lesion group was analysed separately. Among 84 lesions observed at angiography, three were 54 cases of stenosis, 17 of occlusion, and 13 of combined thrombosis. The lesions were located in a proximal vein (n=51), distal vein (n=14), artery (n=6), and at the site of anastomosis (n=13). In the central ...
Recurrent variceal bleeding due to liver cirrhosis led to treatment with a transjugular intrahepatic portosystemic shunt (TIPS) in a pregnant woman at 20 weeks` gestation. Fetal radiation exposure was estimated to be less than 10 mSv. The use of a graduated catheter allowed measurement of field size and reliable determination of the patient`s entrance dose. Radiation exposure of an approximated fetal dosage of 5.2 mSv did not justify abortion for medical reasons. Therefore, TIPS procedure is not generally contraindicated during pregnancy itself. TIPS placement may be a therapeutic option related to the severity of the underlying maternal disease, after radiation exposure of the fetus has been estimated. (orig.) [Deutsch] Bei rezidivierender Oesophagusvarizenblutung auf dem Boden einer Leberzirrhose wurde bei bestehender Schwangerschaft der 20. Woche ein transjugulaerer portosystemischer Stent-Shunt (TIPS) neu angelegt. Praeinterventionell wurde die zu erwartende ...
Purpose: Budd-Chiari syndrome is a fairly uncommon disease in Europe. This often leads to its late diagnosis. The syndrome is characterised by portal hypertension and splanchnic congestion due to obstruction of hepatic venous outflow. This paper describes the treatment of three patients with Budd-Chiari syndrome by interventional therapeutic techniques and discusses alternative treatment modalities. Patients and Methods: The first patient presented with veno-occlusive disease and was treated by the placement of a transjugular intrahepatic portosystemic stentshunt. The second patient showed an occlusion of the major hepatic veins. After percutaneous recanalisation, a stent was placed in the right hepatic vein which remained patent. The third patient had a membranous obstruction of the right hepatic vein which was treated by percutaneous balloon dilatation. Results: In all patients the clinical symptoms resolved completely after treatment and no complications were ...