British Library Electronic Table of Contents (United Kingdom)
Over a 6.5-year period a total of 2554 values were reported by nine laboratories for 259 certified or reference nutrient concentrations in 26 certified reference materials (CRM) submitted to contract laboratories, blinded, as part of the qualifying process for analytical contracts and in the routine sample stream as part of the National Food and Nutrient Analysis Program. Each value was converted to a Z?-score, reflecting the difference from the assigned value related to the combined expected analytical uncertainty plus the uncertainty in the CRM value. Z?-scores >|3.0| were considered unacceptable. For some nutrients (Na, folate, dietary fiber, pantothenic acid, thiamin, tocopherols, carotenoids, monounsaturated, and polyunsaturated fatty acids), >20% of Z?-scores were >|3.0|. For total f...
2007-01-01
Atlas of nuclear medicine imaging
Energy Technology Data Exchange (ETDEWEB)
An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)
1981-01-01
Impact of computers in radiography: the advent of digital radiography, part-2
International Nuclear Information System (INIS)
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
2008-08-01
Real time neutron radiography using a Lixi neutron imaging device
Energy Technology Data Exchange (ETDEWEB)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be ...
1986-01-15
Real time neutron radiography using a Lixi neutron imaging device
International Nuclear Information System (INIS)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further ...
1986-01-01
An Effective Method of Image Retrieval using Image Mining Techniques
The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with ...
2010-01-01
Digital processing to improve image quality in real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a ...
1985-01-01
Digital processing to improve image quality in real-time neutron radiography
International Nuclear Information System (INIS)
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a ...
1985-01-01
Particle-Sizing System for Scanning Electron Microscope ...
... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...
1991-03-01
A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber
... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...
Phantom and animal imaging studies using PLS synchrotron X-rays
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy ...
2001-01-01
UK PubMed Central (United Kingdom)
Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available
2010-03-01
Diagnostic radiology: An Anglo-American textbook of imaging
Energy Technology Data Exchange (ETDEWEB)
This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.
1986-01-01
Portal localization images using computed radiography for high-energy electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy ...
2002-09-01
CR portal imaging; A linac graphy using storage phosphor imaging systems
Energy Technology Data Exchange (ETDEWEB)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
1992-07-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
Energy Technology Data Exchange (ETDEWEB)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the ...
1994-08-01
Development of the high sensitivity real-time neutron radiography for low-flux neutron sources
International Nuclear Information System (INIS)
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the ...
1994-01-01
High-resolution beta imaging; L'imagerie beta haute resolution
Energy Technology Data Exchange (ETDEWEB)
For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and ...
2007-04-15
International Nuclear Information System (INIS)
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of ...
2002-03-01
MR imaging in neuroborreliosis of the cervical spinal cord
Energy Technology Data Exchange (ETDEWEB)
The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)
2004-11-01
Dual-channel imaging system for singlet oxygen and photosensitizer for PDT
UK PubMed Central (United Kingdom)
A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available
MER-DIMES : a planetary landing application of computer vision
During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System
2005-01-01
International Nuclear Information System (INIS)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-01
Growth, Characterization and Device Development in ...
... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...
1998-03-01
DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics
... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....
An Integrated Approach to Intelligent Systems
... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...
2002-01-01
Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging
Energy Technology Data Exchange (ETDEWEB)
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...
1992-01-01
Subsurface imaging using the spectral polarization difference technique and NIR illumination
Energy Technology Data Exchange (ETDEWEB)
A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.
1999-01-26
Neutron imaging system for neutron tomography, radiography, and beam diagnostics
Energy Technology Data Exchange (ETDEWEB)
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
1995-12-31
Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system
International Nuclear Information System (INIS)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).
Method for the reduction of image content redundancy in large image databases
Energy Technology Data Exchange (ETDEWEB)
A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.
2010-03-02
Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.
Energy Technology Data Exchange (ETDEWEB)
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
1998-09-11
International Nuclear Information System (INIS)
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...
1992-01-01
MR imaging of musculoskeletal trauma to the pelvis and the lower limb
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
1999-03-01
MTF analysis of the near-real time neutron radiography facility at MURR
International Nuclear Information System (INIS)
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
1981-12-01
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of ...
2007-01-01
A feedforward architecture accounts for rapid categorization
UK PubMed Central (United Kingdom)
Primates are remarkably good at recognizing objects. The level of performance of their visual system and its robustness to image degradations still surpasses the best computer vision systems despite...Full Text Available
2007-04-10
A PC-Based Imaging System for the Naval Postgraduate ...
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
1989-09-01
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector ...
1996-01-01
International Nuclear Information System (INIS)
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was ...
2003-02-01
New real-time MR image-guided surgical robotic system for minimally invasive precision surgery
Energy Technology Data Exchange (ETDEWEB)
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the ...
2008-04-15
Energy Technology Data Exchange (ETDEWEB)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting ...
1984-09-01
International Nuclear Information System (INIS)
The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting ...
1984-01-01
A high-sensitivity small animal SPECT system
International Nuclear Information System (INIS)
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making ...
2009-03-07
Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data
International Nuclear Information System (INIS)
The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which ...
Visualization of liquid metal two-phase flow by a real time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-11-01
Visualization of liquid metal two-phase flow by a real time neutron radiography system
International Nuclear Information System (INIS)
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
1995-01-01
Principium research of real-time neutron radiography in No. 300 reactor
International Nuclear Information System (INIS)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
2002-12-01
Neutron radiography with the cyclotron, 6
International Nuclear Information System (INIS)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
1988-01-01
Reduction of fluoroscopic exposure for the air-contrast barium enema
Energy Technology Data Exchange (ETDEWEB)
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the ...
1983-11-01
Volume 2- Technical Approach - IMAGE Science Center - NASA
Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...
UK PubMed Central (United Kingdom)
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
2009-07-01
Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems
UK PubMed Central (United Kingdom)
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
2010-02-21
Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope
UK PubMed Central (United Kingdom)
The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available
1999-01-01
We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a ...
2011-05-12
A Software System for Data Analysis in Automated DNA?Sequencing
UK PubMed Central (United Kingdom)
Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available
1998-06-01
Quantitative imaging of turbulent and reacting flows
Energy Technology Data Exchange (ETDEWEB)
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...
1993-12-01
Hybrid Camera Surveillance System Using Robust Human Detection
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
In this paper, the multisource geoscientific data, such as TM data, NOAA data, the data of Bouguer gravity anomaly and aeromagnetic anomaly, the multisource geophysical processing methods, such as upward continuations, vertical derivative and gradient image, and synthetic image processing method - remote sensing image processing and geophysical image processing under I{sup 2}S600, are used to study the reverse faults or thrusts in the southern margin of Ordos basin, China. On the basis of these results and with geological investigation in the field, the authors have determined three thrust compression systems, named EW thrust compression system, NE thrust compression system and NW thrust compression system. These three systems reveal the regularity of geological structural evolution in the southern ...
1996-08-01
Improved quadrant anode image sensor with microchannel plates
Energy Technology Data Exchange (ETDEWEB)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-15
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
An improved quadrant anode image sensor with microchannel plates
International Nuclear Information System (INIS)
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).
1987-11-01
An improved quadrant anode image sensor with microchannel plates
We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.
1987-11-01
Gastrointestinal radiography using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
1985-01-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
1984-10-01
An application of the neutron television fluoroscopic system to neutron computed tomography
International Nuclear Information System (INIS)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image
Energy Technology Data Exchange (ETDEWEB)
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, ...
1985-01-01
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of ...
1983-09-15
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of ...
1983-09-01
A Multi-Layered Image Cache for Scientific Visualization
Energy Technology Data Exchange (ETDEWEB)
We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.
2003-06-26
SUBMIT TO: AM105 CONFERENCE TITLE: Earth Observing Systems VI - NASA
BAE SYSTEMS Infrared Imaging Systems. MS 209. 2 Forbes Road. Lexington, MA 02421 -7306. (781) 863-3762. (781) 863-4809 (fax) ken.overoye @lmco.com ...
X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating
International Nuclear Information System (INIS)
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
2010-06-23
Real time neutron radioscopy - trends and applications
International Nuclear Information System (INIS)
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
2003-11-12
British Library Electronic Table of Contents (United Kingdom)
This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...
2009-01-01
Feasibility study of the iterative x-ray phase retrieval algorithm
International Nuclear Information System (INIS)
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
2009-01-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
Energy Technology Data Exchange (ETDEWEB)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were ...
1991-12-01
Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and ...
1991-01-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Imaging Three Dimensional Two-Particle Correlations for Heavy-Ion Reaction Studies
Energy Technology Data Exchange (ETDEWEB)
The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.
2005-06-27
Characterization of Adaptive Optics at Keck Observatory
Energy Technology Data Exchange (ETDEWEB)
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
2003-07-24
International Nuclear Information System (INIS)
Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...
2005-10-01
A look ahead: PET/MR versus PET/CT
Energy Technology Data Exchange (ETDEWEB)
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as ...
2009-03-15
Real-time neutron monitoring method using an imaging plate
Energy Technology Data Exchange (ETDEWEB)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection ...
1999-07-01
Real-time neutron monitoring method using an imaging plate
International Nuclear Information System (INIS)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection ...
1999-04-19
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-15
Enhanced Reliability MEMS Deformable Mirrors for Space Imaging ...
Sep 3, 2010 ... These higher-quality deformable mirrors will enable diffraction-limited performance for many space-based optical systems such as space-based ...
3-D brain CT image display for planning of craniofacial operation
International Nuclear Information System (INIS)
The authors have been developing a 3D brain CT image display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CT images and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
International Nuclear Information System (INIS)
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
1996-07-01
Tolerance limits of X-ray image intensity
International Nuclear Information System (INIS)
Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
Cerebral angiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).
1985-01-01
Electrical biasing and voltage contrast imaging in a focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, ...
1995-09-01
Direct digital radiography vs conventional radiography of thoracic spine: a comparative study
International Nuclear Information System (INIS)
Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...
2005-09-01
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-06-01
Validity of the CT to attenuation coefficient map conversion methods
International Nuclear Information System (INIS)
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
2004-04-27
ISR; A database for symbolic processing in computer vision
Energy Technology Data Exchange (ETDEWEB)
Computer vision imposes unique requirements on the representation and manipulation of image data and knowledge. At a vision system's lowest level are sensors that represent an image with purely numeric image arrays, while at the highest level are semantic world models that provide the final interpretation of the scene. In between are thousands of intermediate descriptions, many of which must be repeatedly accessed and processed during interpretation. In this article, the authors describe a representation and management system for use at the intermediate (symbolic) level of vision. Based on database management methodology, the intermediate symbolic representation (ISR) mediates access to intermediate-level vision data and forms an active interface to the higher-level inference processes that construct an image's interpretation. The ...
1989-12-01
Energy Technology Data Exchange (ETDEWEB)
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
1998-12-01
Evaluation of the chest radiography using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.
1991-12-01
Confocal Imaging of Biological Tissues Using Second Harmonic Generation
Energy Technology Data Exchange (ETDEWEB)
A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.
2000-03-06
Clinical magnetic resonance imaging with nuclear medicine correlation
Energy Technology Data Exchange (ETDEWEB)
The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.
1985-08-01
Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms
International Nuclear Information System (INIS)
The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...
2007-07-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
Energy Technology Data Exchange (ETDEWEB)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value ...
1987-03-01
Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer
International Nuclear Information System (INIS)
A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...
1989-08-01
Screen-film-combinations for radiography - present and future spectrum of application
Energy Technology Data Exchange (ETDEWEB)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.
1985-01-01
Screen-film-combinations for radiography - present and future spectrum of application
International Nuclear Information System (INIS)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).
Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer
International Nuclear Information System (INIS)
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...
2008-05-07
PET and MRI in cardiac imaging: from validation studies to integrated applications
International Nuclear Information System (INIS)
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance ...
2009-03-01
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework ...
2010-01-01
Fundamental concepts of digital image processing
The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A ...
1983-03-01
Camera position estimation and feature extraction from an incomplete image of a landmark
British Library Electronic Table of Contents (United Kingdom)
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
2011-01-01
Electromagnetic tracking in the clinical environment
UK PubMed Central (United Kingdom)
When choosing an electromagnetic tracking system (EMTS) for image-guided procedures several factors must be taken into consideration. Among others these include the system’s refresh rate, the...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
2008-01-01
Colour television, an imitation of the human visual system.
UK PubMed Central (United Kingdom)
Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available
1975-07-01
Classification of hematologic malignancies using texton signatures
UK PubMed Central (United Kingdom)
We describe a decision support system to distinguish among hematology cases directly from microscopic specimens. The system uses an image database containing digitized specimens from normal...Full Text Available
2007-10-01
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light ...
2009-12-01
International Nuclear Information System (INIS)
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light ...
2009-12-01
FCR (Fuji Computed Radiography) in neurosurgery
Energy Technology Data Exchange (ETDEWEB)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
1988-08-01
FCR (Fuji Computed Radiography) in neurosurgery
International Nuclear Information System (INIS)
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
1988-01-01
Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)
1996-12-31
Groundtruth approach to accurate quantitation of fluorescence microarrays
Energy Technology Data Exchange (ETDEWEB)
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)
1997-05-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above ...
1993-01-01
A three-dimensional display system for brain CT images
International Nuclear Information System (INIS)
Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two ...
Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study
Energy Technology Data Exchange (ETDEWEB)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-12-01
International Nuclear Information System (INIS)
In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...
1987-01-01
MTF analysis of the MURR real-time neutron radiography facility
International Nuclear Information System (INIS)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri ...
1982-04-01
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
Energy Technology Data Exchange (ETDEWEB)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential ...
2009-07-01
Development of a neutron imaging facility at the CENM Al Maamora TRIGA
International Nuclear Information System (INIS)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential ...
2009-06-07
Neutron radiography with the cyclotron, 5
International Nuclear Information System (INIS)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
1987-01-01
[The study of the mixing layer by the point image method].
The properties of the mixing layer in dynamic systems were studied by the example of a mathematical model of the cubic image type. Its role in the generation of information and the evolution of its significance was shown. At the moment of generation, information is of zero significance, and this significance then increases. A criterion of efficiency was proposed, and the optimum moment of making a decision in creative work was determined. It was shown that the increase in the variability of the parameters of a living system upon entry into the mixing layer and its decrease upon exit can serve as objective indicators of the transition of the system from one dynamic regime (attractor) to another. PMID:12723364
Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
1996-12-31
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
International Nuclear Information System (INIS)
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI ...
2010-11-21
Computer vision algorithms in DNA ploidy image analysis
The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation ...
2006-03-01
Evaluation of performance and characteristics of neutron radiography and standardization
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the ...
1995-02-01
International Nuclear Information System (INIS)
The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)
2008-09-01
International Nuclear Information System (INIS)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...
2002-12-01
Imaging properties of the Medipix2 system exploiting single and dual energy thresholds
Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 ...
2006-01-01
Spectral characteristics of lignite open cast mining systems: a preliminary status
Energy Technology Data Exchange (ETDEWEB)
The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.
1999-07-01
Model of quantum noise of shadow radiation images
International Nuclear Information System (INIS)
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Imaging findings of central nervous system neuroepithelial cysts
Energy Technology Data Exchange (ETDEWEB)
Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.
1998-05-01
Diagnostic imaging of the acutely injured patient
Energy Technology Data Exchange (ETDEWEB)
This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.
1985-01-01
Refrigerator operating experience on whole body MRI magnet systems
International Nuclear Information System (INIS)
Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.
1985-08-01
Scoring of brain maturation in developmentally handicapped children with high-field MR imaging
International Nuclear Information System (INIS)
A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.
Pharmaceutical applications of non-linear imaging
British Library Electronic Table of Contents (United Kingdom)
Non-linear optics encompasses a range of optical phenomena, including two- and three-photon fluorescence, second harmonic generation (SHG), sum frequency generation (SFG), difference frequency generation (DFG), third harmonic generation (THG), coherent anti-Stokes Raman scattering (CARS), and stimulated Raman scattering (SRS). The combined advantages of using these phenomena for imaging complex pharmaceutical systems include chemical and structural specificities, high optical spatial and temporal resolutions, no requirement for labels, and the ability to image in an aqueous environment. These features make such imaging well suited for a wide range of pharmaceutical and biopharmaceutical investigations, including material and dosage form characterisation, dosage form digestion and drug rele...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
2009-01-01
Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging
International Nuclear Information System (INIS)
This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.
1990-11-25
Automatic Extraction of Open Space Area from High Resolution Urban Satellite Imagery
In the 21st century, Aerial and satellite images are information rich. They are also complex to analyze. For GIS systems, many features require fast and reliable extraction of open space area from high resolution satellite imagery. In this paper we will study efficient and reliable automatic extraction algorithm to find out the open space area from the high resolution urban satellite imagery. This automatic extraction algorithm uses some filters and segmentations and grouping is applying on satellite images. And the result images may use to calculate the total available open space area and the built up area. It may also use to compare the difference between present and past open space area using historical urban satellite images of that same projection
2011-01-01
Angiography of the head using Fuji computed radiography (FCR) system
International Nuclear Information System (INIS)
Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).
1985-01-01
Verification of electron beam therapy with storage phosphor images: Precision of field placement
Energy Technology Data Exchange (ETDEWEB)
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in ...
1990-04-01
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional ...
1994-02-01
Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo
Energy Technology Data Exchange (ETDEWEB)
Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in ...
2008-12-15
Energy Technology Data Exchange (ETDEWEB)
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other ...
1998-11-01
Recent developments and applications for the University of Texas thermal neutron imaging facility
Energy Technology Data Exchange (ETDEWEB)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been ...
2001-07-01
UK PubMed Central (United Kingdom)
Microbes in nature frequently function as members of complex multitaxon communities, but the structural organization of these communities at the micrometer level is poorly understood because of limitations...Full Text Available
2011-03-08
Silica-Based Nanoparticle Uptake and Cellular Response by Primary Microglia
UK PubMed Central (United Kingdom)
BackgroundSilica nanoparticles (SiNPs) are being formulated for cellular imaging and for nonviral gene delivery in the central nervous system (CNS), but it is unclear what potential...Full Text Available
2010-05-01
UK PubMed Central (United Kingdom)
BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available
Proceedings of the eighth West Virginia University international mining electrotechnology conference
Energy Technology Data Exchange (ETDEWEB)
A total of 25 papers were presented at the conference in 6 sessions: illumination and communication; power and safety; knowledge based systems; mine-wide monitoring; instrumentation control and automation; remote sensing and imaging.
1986-01-01
UK PubMed Central (United Kingdom)
Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available
1991-06-01
Generation and control of sound bullets with a nonlinear acoustic lens
UK PubMed Central (United Kingdom)
Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available
2010-04-20
Fragment-Based Learning of Visual Object Categories in Non-Human Primates
UK PubMed Central (United Kingdom)
When we perceive a visual object, we implicitly or explicitly associate it with an object category we know. Recent research has shown that the visual system can use local, informative image fragments...Full Text Available
Evaluation of a filmless radiology pilot--a preliminary report.
UK PubMed Central (United Kingdom)
The development of the Multimedia Electronic Medical Record System (MEMRS) promises new opportunities to significantly reduce the routine use of film as the medium for viewing radiological medical images....Full Text Available
2001-01-01
Double-Valve Libman-Sacks Endocarditis Causing Ventricular Fibrillation Cardiac Arrest
UK PubMed Central (United Kingdom)
Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
Simplification of cell enumeration technologies is necessary, especially for resource-poor countries, where reliable and affordable enumeration systems are greatly needed. In this paper, an immunomagnetic...Full Text Available
2007-04-01
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
Energy Technology Data Exchange (ETDEWEB)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the ...
2002-04-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
International Nuclear Information System (INIS)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the ...
2002-04-01
The profusion of online digital images presents new challenges for image indexing. Images have always been problematic to describe and catalogue due to lack of inherent textual data and ambiguity of meaning. An alternative to time-consuming professionally-applied metadata has been sought in the form of tags, simple keywords that form a flat structure known as distributed classification, or more popularly as a folksonomy. This research aims to increase understanding of why people tag and how effective they find it for searching, using as the focus. Open-ended questionnaires were sent out to members of the photo-sharing website Flickr, with the opportunity to post comments to an online discussion space. There is also a systematic comparison between a tag-based system and a more traditional controlled vocabulary, to test out the claims made regarding the suitability of tagging for searching and browsing. ...
2009-01-01
Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF
Energy Technology Data Exchange (ETDEWEB)
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of ...
2004-04-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
1987-03-01
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
Disk's Spiral Arms Point to Possible Planets
National Aeronautics and Space Administration (NASA)
Simulations of young stellar systems suggest that planets embedded in a circumstellar disk can produce many distinctive structures, including rings, gaps and spiral arms. This video compares computer simulations of hypothetical systems to an image of system SAO 206462 taken by the Subaru Telescope and its HiCIAO instrument. n nCredit: NASA Goddard Space Flight Center/NCSA
2011-10-18
System suitable for use in neutron radiography
Energy Technology Data Exchange (ETDEWEB)
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
1990-02-07
System suitable for use in neutron radiography
International Nuclear Information System (INIS)
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
1988-07-20
Neutron radiography with the cyclotron, 4
International Nuclear Information System (INIS)
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the ...
1986-01-01
Computed radiography for major airway in pediatrics
International Nuclear Information System (INIS)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate ...
1986-01-01
Electronic imaging system for neutron radiography at a low power research reactor
Energy Technology Data Exchange (ETDEWEB)
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
2010-08-15
Electronic imaging system for neutron radiography at a low power research reactor
International Nuclear Information System (INIS)
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
2010-08-01
Ultra high field magnetic resonance imaging
International Nuclear Information System (INIS)
Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an ...
We develop a 3-D model to simulate the synthetic aperture radar (SAR) image formation process of an undulated vegetation canopy such as corn grown in fields with large periodic drainage reliefs. We explain how the simulated SAR image of undulated vegetation medium is obtained by the convolution of a 2-D slice of the 3-D simulated SAR system point spread function [(PSF), emulating the SAR beam modeled by a cosine modulated Gaussian], with the 2-D projection of the observed undulated vegetation canopy (modeled with scatterers randomly distributed in 3-D undulated space) followed by the extraction of each look envelope, the summation of looks, and sampling in azimuthal and range directions. Our model is useful to study the parameters involved in the formation and the analysis of SAR images of undulated vegetation medium. Validation of simulations made with actual SAR images shows that ...
2001-10-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear ...
1987-01-01
Assessment of the effects of pixel loss on image quality in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more ...
2004-03-21
Assessment of the effects of pixel loss on image quality in direct digital radiography
International Nuclear Information System (INIS)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the ...
2004-03-21
International Nuclear Information System (INIS)
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...
1992-03-01
A novel approach to personal photo album representation and management
In this paper we present a novel approach to personal photo album management allowing the end user to efficiently access the collection without any need for tedious manual annotation or indexing of the photos. The proposed work exploits methods and technology from the field of computer vision and pattern recognition for face detection, face representation and image annotation to automatically create description of images useful for content-based searching and retrieval. In fact, even if most of the used techniques are not reliable enough to address the general problem of content-based image retrieval, we show that, in a limited domain such as the one of personal photo album, it is possible to obtain results that improve the browsing capabilities of current photo album management systems. In particular, starting from the observation that most personal photos depict a usually small number of people in a ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
2003-03-15
International Nuclear Information System (INIS)
The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver ...
2003-03-01
Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a Human-Camera Synchronization Model. By controlling the active camera with ...
2008-04-01
Experience in using Fuji computed radiography (FCR), 1
Energy Technology Data Exchange (ETDEWEB)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey ...
1984-12-01
Experience in using Fuji computed radiography (FCR), 1
International Nuclear Information System (INIS)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey ...
1984-01-01
Keck Diffraction-Limited Imaging of the Young Quadruple Star System HD 98800
This paper presents diffraction-limited 1-18 micron images of the young quadruple star system HD 98800 obtained with the W. M. Keck 10-m telescopes using speckle and adaptive optics imaging at near-IR wavelengths and direct imaging at mid-IR wavelengths. The two components of the visual binary, A and B, both themselves spectroscopic binaries, were separable at all wavelengths, allowing us to determine their stellar and circumstellar properties. Combining these observations with spectroscopic data from the literature, we derive an age of 10 Myr, masses of 0.93 and 0.64 M_sun and an inclination angle of 58 deg for the spectroscopic components of HD 98800 B, and an age of 10 Myr and a mass of 1.1 M_sun for HD 98800 Aa. Our data confirm that the large mid-IR excess is entirely associated with HD 98800 B. This excess exhibits a black body temperature of 150 K and a strong 10 micron silicate emission feature. ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification ...
1993-06-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for ...
1994-07-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification ...
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
British Library Electronic Table of Contents (United Kingdom)
Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice.Methods...
2011-01-01
New thermal neutron imaging facility at the University of Texas reactor
Energy Technology Data Exchange (ETDEWEB)
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
1999-09-01
Intracranial Dural Metastasis of Ewing's Sarcoma: a Case Report
International Nuclear Information System (INIS)
Ewing's sarcoma is a malignant bone tumor that can occur anywhere in the body, but it is most commonly observed in the long bones of the arms and legs, the pelvis and in the chest. The predominant sites of metastasis include the lung (38%), bone (including the spine; 31%), and the bone marrow (11%). Metastasis of Ewing's sarcoma to the central nervous system (CNS) is relatively rare, and most of the previous reports have demonstrated involvement of the bony calvarium or brain parenchyma. We describe here the imaging findings of dural metastasis of Ewing's sarcoma, and these imaging findings have not been previously reported on in the medical literature. In conclusion, dural metastasis of Ewing's sarcoma is very rare and its imaging characteristics are similar to those of a primary tumor, which mimic the findings of a schwannoma or meningioma. Despite its rarity, secondary Ewing's sarcoma may be included ...
2008-02-01
Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development
International Nuclear Information System (INIS)
Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...
2002-08-01
Dynamic and static error analyses of neutron radiography testing
Energy Technology Data Exchange (ETDEWEB)
Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static ...
1999-03-01
Quantitative density measurements from a real-time neutron radiography system
Energy Technology Data Exchange (ETDEWEB)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-01-01
Quantitative density measurements from a real-time neutron radiography system
International Nuclear Information System (INIS)
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
1986-11-16
Nuclear fuel assembly identification using computer vision
This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.
1985-11-01
Artificial intelligence: the future in nuclear plant maintenance
Energy Technology Data Exchange (ETDEWEB)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-12-01
Artificial intelligence: the future in nuclear plant maintenance
International Nuclear Information System (INIS)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-09-23
Real-time neutron radiography at the Iea-R1 m nuclear research reactor
International Nuclear Information System (INIS)
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
Radiographic images generated by the real-time neutron radiography system (RTNR) are analyzed by customized image processing software of the determination of instantaneous void fraction distribution. The cross-sectional averaged axial void fraction profiles and the two-dimensional void fraction profiles are determined simultaneously for each image. Various flow regimes are generated to determine if the RTNR system can accurately predict the void distribution in the radial, axial, and temporal coordinates. The results show the RTNR system correctly determines the void fraction distribution for each flow regime; however, accuracy decreases with decreasing void fraction. For net water thicknesses > 1.0 cm, the accuracy decreases with increasing water thickness due to the extreme sensitivity of thermal neutron interactions with light water. Heavy water is a more ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage ...
1983-01-01
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional ...
2003-05-01
Targeted drug delivery under MRI guidance
British Library Electronic Table of Contents (United Kingdom)
The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...
2008-01-01
Real-time imaging for neutron radiography at KURRI
International Nuclear Information System (INIS)
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
1987-07-01
International Lens Design Conference, Monterey, CA, June 11-14, 1990, Proceedings
Energy Technology Data Exchange (ETDEWEB)
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of ...
1990-01-01
Technetium complexes as potential brain imaging agents
International Nuclear Information System (INIS)
Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).
Energy Technology Data Exchange (ETDEWEB)
Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.
1985-01-01
International Nuclear Information System (INIS)
Radiology departments often underestimate the importance of protecting medical data during transmission, including the precautions taken to ensure data protection. In teleradiology, transmitted as well as stored patient data have to be signed digitally according to the currently valid regulation (Roentgenverordnung, RoeV). The DICOM standard facilitates a digital signature. So far, medical image manufacturers only announced to support this security feature. We introduce a solution that extends the feature of digital signing to older modalities. (orig.)
2005-01-01
UK PubMed Central (United Kingdom)
Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available
2009-03-01
Measurements of nuclear emulsion tracks by means of a picture analysis system
Energy Technology Data Exchange (ETDEWEB)
A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.
1987-03-01
International Nuclear Information System (INIS)
Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).
1987-01-01
Real-time neutron radiography at Texas A and M University
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a ...
1990-12-20
Real-time neutron radiography at Texas A and M University
International Nuclear Information System (INIS)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a ...
1990-12-01
Introducing DeBRa: a detailed breast model for radiological studies
Energy Technology Data Exchange (ETDEWEB)
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The ...
2009-07-21
Evaluation of FCR system by means of NEQ(u)
Energy Technology Data Exchange (ETDEWEB)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We ...
1991-07-01
Evaluation of FCR system by means of NEQ(u)
International Nuclear Information System (INIS)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We ...
1991-01-01
Representation of uncertainty in computer vision using fuzzy sets
Energy Technology Data Exchange (ETDEWEB)
Uncertainty in computer vision can arise at various levels. It can occur in the low level in the raw sensor input, and extends all the way through intermediate and higher levels. Ideally, at any level where decisions are being made on the basis of previous processing steps, a computer vision system must have sufficient flexibility for representation of uncertainty in any of these levels. The input cue representation portion of a computer vision system should maintain the information content of the original input images, while at the same time allowing for uncertainty in the identification of attributes required by other parts of the system for decision making. Processes such as edge detection, segmentation, and shape matching yield results which could bias higher level decision making, unless some framework is defined for the representation of uncertainty in the context of fuzzy set theory where ...
1986-02-01
MR imaging of regional late brain development
International Nuclear Information System (INIS)
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential ...
Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment
Energy Technology Data Exchange (ETDEWEB)
Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam ...
2009-01-29
Real-time neutron radiography system performance - Measurements and methods
Energy Technology Data Exchange (ETDEWEB)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...
1988-09-01
Real-time neutron radiography system performance - Measurements and methods
International Nuclear Information System (INIS)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...
1988-01-01
Development of lidar techniques for environmental studies
Energy Technology Data Exchange (ETDEWEB)
The lidar group in Lund has performed many DIAL measurements with a mobile lidar system that was first described in 1987. The lidar system is based on a Nd:YAG-pumped dye laser. During the last few years the lidar group has focused on fluorescence imaging and mercury measurements in the troposphere. In 1994 we performed two campaigns: one fluorescence imaging measurement campaign outside Avignon, France and one unique lidar campaign at a mercury mine in Almaden, Spain. Both campaigns are described in this thesis. This thesis also describes how the mobile lidar system was updated with the graphical programming language LabVIEW to obtain a user friendly lidar system. The software controls the lidar system and analyses measured data. The measurement results are shown as maps of species concentration. All electronics and the major parts of the ...
1996-09-01
Design of multifunction anti-terrorism robotic system based on police dog
Aimed at some typical constraints of police dogs and robots used in the areas of reconnaissance and counterterrorism currently, the multifunction anti-terrorism robotic system based on police dog has been introduced. The system is made up of two parts: portable commanding device and police dog robotic system. The portable commanding device consists of power supply module, microprocessor module, LCD display module, wireless data receiving and dispatching module and commanding module, which implements the remote control to the police dogs and takes real time monitor to the video and images. The police dog robotic system consists of microprocessor module, micro video module, wireless data transmission module, power supply module and offence weapon module, which real time collects and transmits video and image data of the counter-terrorism sites, and gives military ...
2007-11-01
A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR
Energy Technology Data Exchange (ETDEWEB)
This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content ...
2005-04-01
Optical Images Due to Lenses and Mirrors
... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...
Fast Implementation of Matched Filter Based Automatic Alignment Image Processing
Energy Technology Data Exchange (ETDEWEB)
Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field programmable logic array (FPGA) to speed up these computations. The ...
2008-04-02
This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a ...
2011-04-01
Determination of Inter-Phase Line Tension in Langmuir Films
A Langmuir film is a molecularly thin film on the surface of a fluid; we study the evolution of a Langmuir film with two co-existing fluid phases driven by an inter-phase line tension and damped by the viscous drag of the underlying subfluid. Experimentally, we study an 8CB Langmuir film via digitally-imaged Brewster Angle Microscopy (BAM) in a four-roll mill setup which applies a transient strain and images the response. When a compact domain is stretched by the imposed strain, it first assumes a bola shape with two tear-drop shaped reservoirs connected by a thin tether which then slowly relaxes to a circular domain which minimizes the interfacial energy of the system. We process the digital images of the experiment to extract the domain shapes. We then use one of these shapes as an initial condition for the numerical solution of a boundary-integral model of the underlying hydrodynamics and compare the ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR ...
2001-03-01
Development of a computerized portal verification scheme for pelvic treatment fields
International Nuclear Information System (INIS)
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing ...
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.
2003-07-01
Endomicroscopy imaging of epithelial structures using tissue autofluorescence
We explore autofluorescence endomicroscopy as a potential tool for real-time visualization of epithelial tissue microstructure and organization in a clinical setting. The design parameters are explored using two experimental systems--an Olympus Medical Systems Corp. stand-alone clinical prototype probe, and a custom built bench-top rigid fiber conduit prototype. Both systems entail ultraviolet excitation at 266 nm and/or 325 nm using compact laser sources. Preliminary results using ex vivo animal and human tissue specimens suggest that this technology can be translated toward in vivo application to address the need for real-time histology.
2011-04-01
Commercialization of uncooled infrared technology
BAE Systems is the leading producer of uncooled microbolometer based thermal imaging engines in the world. Initial investments to develop and produce uncooled infrared (IR) technology were primarily driven by military applications, but it was the commercial market with the potential for large product volumes which provided BAE Systems with the business model required for investment in uncooled IR technology. This paper reviews the heritage of BAE Systems technology and current products and is an example of the success of a Dual-Use technology area which DARPA invested in during the 1990s.
2004-10-01
Two-photon calcium imaging from head-fixed Drosophila during optomotor walking behavior
British Library Electronic Table of Contents (United Kingdom)
Drosophila melanogaster is a model organism rich in genetic tools to manipulate and identify neural circuits involved in specific behaviors. Here we present a technique for two-photon calcium imaging in the central brain of head-fixed Drosophila walking on an air-supported ball. The ball's motion is tracked at high resolution and can be treated as a proxy for the fly's own movements. We used the genetically encoded calcium sensor, GCaMP3.0, to record from important elements of the motion-processing pathway, the horizontal-system lobula plate tangential cells (LPTCs) in the fly optic lobe. We presented motion stimuli to the tethered fly and found that calcium transients in horizontal-system neurons correlated with robust optomotor behavior during walking. Our technique allows both behavior ...
2010-01-01
Quantitation of Cellular Dynamics in Growing Arabidopsis Roots with Light Sheet Microscopy
To understand dynamic developmental processes, living tissues must be imaged frequently and for extended periods of time. Root development is extensively studied at cellular resolution to understand basic mechanisms underlying pattern formation and maintenance in plants. Unfortunately, ensuring continuous specimen access, while preserving physiological conditions and preventing photo-damage, poses major barriers to measurements of cellular dynamics in indeterminately growing organs such as plant roots. We present a system that integrates optical sectioning through light sheet fluorescence microscopy with hydroponic culture that enables us to image at cellular resolution a vertically growing Arabidopsis root every few minutes and for several consecutive days. We describe novel automated routines to track the root tip as it grows, track cellular nuclei and identify cell divisions. We demonstrate the ...
2011-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 ..mu.., allows individual MCP channels to be distinguished. (AIP)
1976-11-01
International Nuclear Information System (INIS)
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, approx. =10 #mu#, allows individual MCP channels to be distinguished.
9472-01-01
Normalized noise power spectrum of full field digital mammography detector system
International Nuclear Information System (INIS)
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
Normalized Noise Power Spectrum of Full Field Digital Mammography System
International Nuclear Information System (INIS)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
2010-01-05
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this ...
1992-07-01
We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. ...
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM ...
2009-12-15
Acceptance testing in digital systems of mammography. Protocols applicability
International Nuclear Information System (INIS)
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those ...
WR 104: Are We Looking Down The Gun Barrel of a Future GRB?
WR 104 is the prototype for a small but growing group of stars that present the remarkably striking appearance of pinwheels. High resolution images of WR 104 show the (apparently) face-on spiral turning with an 8 month period. The pinwheel is assumed to be composed of dust produced via colliding winds in a low-inclination WR+OB binary. These assumptions have been very successful in modeling the imaging, but remain largely untested by spectroscopy. Strong motivation for further study of this system has emerged. Recent theory suggests that some gamma-ray bursts (GRB's) are core-collapse supernovae viewed nearly pole-on. The WC class Wolf-Rayet star in WR 104 is the type of star thought to be a possible GRB progenitor. If the orbit (and thus stellar rotation axes) are pole-on, the effects on Earth's biosphere could be significant. Confrontation of the face-on colliding-wind binary model with eight years of spectroscopy, ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
To keep up with the speeds of modern production lines, most machine vision applications require very powerful computers (often parallel-processing machines), which process millions of points of data in real time. The human brain performs approximately 100 billion logical floating-point operations each second. That is 400 times the speed of a Cray-1 supercomputer. The right software must be developed for parallel-processing computers. The NSF has awarded Rensselaer Polytechnic Institute (Troy, N.Y.) a $2 million grant for parallel- and image-processing software research. Over the last 15 years, Rensselaer has been conducting image-processing research, including work with high-definition TV (HDTV) and image coding and understanding. A similar NSF grant has been awarded to Michigan State University (East Lansing, Mich.) Neural networks are supposed to emulate human learning patterns. These networks and their hardware ...
1989-06-01
Energy-filtered electron microscopy for imaging core-shell nanostructures
Energy Technology Data Exchange (ETDEWEB)
CuAg core-shell nanoparticles are synthesized by ultra-high vacuum thermal evaporation. We show on this system how the Energy-Filtered Transmission Electron Microscopy (EFTEM) technique allows one to improve the characterization by precisely pointing out the formation of core-shell arrangements in bimetallic nanoparticle assemblies. A criterion to measure the shell thickness from EFTEM images on unique core-shell nanoparticles is defined, that can be used for core-shell nanoparticles of any sizes, with shell thicknesses over 1 nm. It is based on the intensity variation along a line drawn across a core-shell nanoparticle on a EFTEM image. This criterion has been validated by a close comparison of the shell thickness measurements performed in this work and the ones obtained by acoustic micro-Raman spectroscopy. Using this criterion, we report a strong correlation between the size of the Cu cores and the formation of the ...
2008-08-15
An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial ...
2010-07-19
Biopolymer system for permeability modification in porous media
Energy Technology Data Exchange (ETDEWEB)
New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution ...
1995-12-31
Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors
Energy Technology Data Exchange (ETDEWEB)
Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The ...
2001-04-01
Focused ion beam assisted three-dimensional rock imaging at submicron scale
Energy Technology Data Exchange (ETDEWEB)
Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of ...
2003-05-09
Energy Technology Data Exchange (ETDEWEB)
The use of the focused ion beam (FIB) systems has increased to a high level in recent years. The imaging, milling, and deposition capabilities of the FIB make it the ideal instrument for e.g., site-specific failure analysis, specimen preparation and nano-machining. Ion channelling contrast allows for selective imaging of polycrystalline and polyphase microstructures. In addition, the FIB and CrossBeam registered instruments are unique stand-alone analytical tools. Their vast capabilities have enabled numerous applications into the semiconductor and materials sciences applications. These integrated CrossBeam registered Tools enable the observation and direct control of the FIB operation in real time. In addition to the improved accuracy and resolution the electron beam adds analytical capabilities as STEM, EDS and EBSP to the instruments. To ensure a safe and reliable operation of the instrument, a dedicated vacuum ...
2005-07-01
A simple 5-DoF MR-compatible motion signal measurement system.
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, ...
2011-09-01
UK PubMed Central (United Kingdom)
Multiple memory systems are involved in parallel processing of spatial information during navigation. A series of studies have distinguished between hippocampus-dependent ‘spatial’ navigation,...Full Text Available
2011-03-01
Real-time neutron radiography; Radiografia com neutrons em tempo-real
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light ...
2000-07-01
International Nuclear Information System (INIS)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, ...
2000-01-01
Radioactive source management in Daya Bay NPP
International Nuclear Information System (INIS)
'Small radioactive source results in big accident' have occurred repeatedly in China and worldwide alike. Radioactive source management is one of the key activities for a nuclear power plant to maintain its good safety record and image to the public. From aspects of establishing the management system, centralized storage, periodic accounting, performing whole process control to the source usage and experience feedback etc., the author reports the practice and experience of radioactive source management in Daya Bay Nuclear Power Plant
1999-11-01
Proceedings of the 1991 ASME JSME thermal engineering joint conference
International Nuclear Information System (INIS)
This book is organized under the following headings: Electrohydrodynamic heat transfer augmentation; Forced convection augmentation and heat transfer control; Turbulent heat transfer; Thermal problems in the environment; Energy conversion systems; Measurement, visualization, and imaging; Thermal problems in space technology; and Thermal properties.
1991-03-17
Micromachining using focused ion beams
Energy Technology Data Exchange (ETDEWEB)
Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)
1994-11-16
Clinical helical tomotherapy commissioning dosimetry
International Nuclear Information System (INIS)
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
2003-12-01
Java Image I/O for VICAR, PDS, and ISIS
This library, written in Java, supports input and output of images and metadata (labels) in the
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different phases of the steam stimulation process to examine the relation ...
1994-12-31
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to ...
1989-03-01
A non-local approach for image super-resolution using intermodality priors ?
UK PubMed Central (United Kingdom)
Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available
2010-08-01
Energy Technology Data Exchange (ETDEWEB)
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.
1987-04-01
Dual-energy projection radiography using condenser discharge x-ray generator and FCR
International Nuclear Information System (INIS)
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).
1987-01-01
Computer simulation and scientific visualization
Energy Technology Data Exchange (ETDEWEB)
The simulation of processes in engineering and the physical sciences has progressed rapidly over the last several years. With rapid developments in supercomputers, parallel processing, numerical algorithms and software, scientists and engineers are now positioned to quantitatively simulate systems requiring many billions of arithmetic operations. The need to understand and assimilate such massive amounts of data has been a driving force in the development of both hardware and software to create visual representations of the underling physical systems. In this paper, and the accompanying videotape, the evolution and development of the visualization process in scientific computing will be reviewed. Specific applications and associated imaging hardware and software technology illustrate both the computational needs and the evolving trends. 6 refs.
1990-01-01
Application of neutron radiography to a diagnosis of refrigerator
International Nuclear Information System (INIS)
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
1996-07-01
Performance of a low cost solar paraboloidal dish steam generating system
Energy Technology Data Exchange (ETDEWEB)
This paper presents the design, development and performance characteristics of a low cost solar steam generating system which incorporates recent design and materials innovations of parabolic dish technology. The concentrator is a deep dish of rather imperfect optics, made of silvered polymer reflectors fitted in the aluminum frame of a satellite communication dish. Conventional cavity receivers tend to be inadequate for this concentrator. Semi-cavity and modified cavity receivers, thermally optimised, with the fuzzy focal image have, therefore, been investigated. Preliminary field measurements and cost, as well as performance analyses of the system, indicate a solar to steam conversion efficiency of 70-80% at 450{sup o}C and a collector system cost of Rs 8000-9000/m{sup 2} (1 US dollar = Rs, 40.0). (author)
2000-05-01
Application of digital radiography to diagnosis of laryngeal diseases
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis ...
1986-01-01
A playmate robot system for playing the rock-paper-scissors game with humans
British Library Electronic Table of Contents (United Kingdom)
We have developed a playmate robot system for playing the rock-paper-scissors game with humans. The playmate robot recognizes the hand motions of a human using image processing without attaching any additional units to the human. The playmate robot system consists of three parts: a game management part, a hand motion recognition part, and a robot hand control part. The system functions as follows. (1) Before the game is played, the game management part decides on the motion of the robot hand from amongst rock, paper, and scissors. After the game is played, the robot develops a reaction using speech and facial expressions depending on the result of the game. (2) The hand motion recognition part recognizes the hand motion of the human. It does not use any additional units on the human?s body...
2011-01-01
Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources
We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities > 100 mJy at 500 um, but are not visible in existing optical imaging. We fit light profiles to each component of the lensing systems in Spitzer IRAC 3.6 and 4.5 um data and successfully disentangle the foreground lens from the background source in each case, providing important constraints on the spectral energy distributions (SEDs) of the background SMG at rest-frame optical-near-infrared wavelengths. The SED fits show that these two SMGs have high dust obscuration with Av ~4 to 5 and star formation rates of ~100 M_sun/yr. They have low gas fractions and low dynamical masses compared to 850 um selected galaxies.
2010-01-01
Simulating the operation of photosensor-based lighting controls
International Nuclear Information System (INIS)
Energy savings from the use of daylighting in commercial buildings are realized through implementation of photoelectric lighting controls that dim electric lights when sufficient daylight is available to provide adequate workplane illumination. The dimming level of electric lighting is based on the signal of a photosensor. Current simulation approaches for such systems are based on the questionable assumption that the signal of the photosensor is proportional to the task illuminance. This paper presents a method that simulates the performance of photosensor controls considering the acceptance angle, angular sensitivity, placement of the photosensor within a space, and color correction filter. The method is based on the multiplication of two fisheye images: one generated from the angular sensitivity of the photosensor and the other from a 180- or 360-degree fisheye image of the space as ''seen'' by the photosensor. The paper ...
Reborn quadrant anode image sensor
International Nuclear Information System (INIS)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.
2009-06-01
Reborn quadrant anode image sensor
British Library Electronic Table of Contents (United Kingdom)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...
2009-01-01
Potential new approaches for the development of brain imaging agents for single-photon applications
International Nuclear Information System (INIS)
This paper describes new strategies for the brain-specific delivery of radionuclides that can be used to evaluate regional cerebral perfusion by single photon imaging techniques. A description of several examples of interesting new strategies that have recently been reported is presented. A new approach at this institution for the brain-specific delivery of radioiodinated iodophenylalkyl-substituted dihyronicotinamide systems is described which shows good brain uptake and retention in preliminary studies in rats. Following transport into the brain these agents appear to undergo facile intracerebral oxidation to the quaternized analogues which do not recross the intact blood-brain barrier and so are effectively trapped in the brain. 49 refs., 9 figs., 1 tab.
1984-10-12
Potential new approaches for the development of brain imaging agents for single-photon applications
International Nuclear Information System (INIS)
The goals of this paper are to describe new strategies being pursued at several institutions for the brain-specific delivery of radionuclides that can be used to evaluate regional cerebral perfusion by single photon imaging techniques. A comprehensive review of the literature is beyond the scope of these proceedings and our goal is to, therefore, present a description of several examples of interesting new strategies that have recently been reported. In addition, the authors also describe a new approach being pursued at their institution for the brain-specific delivery of radioiodinated iodophenylaklyl-substituted dihydronicotiamide systems which shows good brain uptake and retention in preliminary studies in rats. Following transport into the brain these agents appear to undergo facile intracerebral oxidation to the quaternized analogues which do not cross the intact blood-brain-barrier and are effectively trapped in the brain.
New procedures. Comprehensive staging of lung cancer by MRI
International Nuclear Information System (INIS)
Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and ...
2010-08-01
International Nuclear Information System (INIS)
A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.
2006-09-01
High speed inverted optical-resolution photoacoustic microscopy
Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.
2011-02-01
Fetal MRI of pathological brain development
International Nuclear Information System (INIS)
Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)
2006-02-01
Evaluation of routine telephone transmission of nuclear medicine studies
Energy Technology Data Exchange (ETDEWEB)
Rapid and reliable transmission of nuclear medicine studies using conventional telephone lines and commercially available modems and computer systems has been accomplished through use of software developed within the authors' hospital. Original digital images of all-night and weekend studies, acquired on any of the acquisition computers from different manufacturers, are now routinely sent for remote reading at the physician's home. Data, software, and letters are routinely exchanged using modems and standard telephone lines with a sister institution in Haifa, Israel. The software has been designed to achieve no loss data compression and minimal turnaround time loss. Thus, an average lung perfusion image or gallbladder study requires about 1-3 minutes of transmission time. Full analysis and display software is available on the remote computer.
1989-01-01
Designing engineering upgradability into magnetic resonance imagers: Impact on future costs
Energy Technology Data Exchange (ETDEWEB)
MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.
1987-02-01
Seismic migration and absorbing boundaries with a one-way wave system for heterogeneous media
Energy Technology Data Exchange (ETDEWEB)
A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained ...
1996-07-01
Focused ion beam damage to MOS integrated circuits
Energy Technology Data Exchange (ETDEWEB)
Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes ...
2000-05-10
Vibration signature analysis of AFM images
Energy Technology Data Exchange (ETDEWEB)
Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging method were ...
1995-12-31
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...
2011-05-05
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...
2007-03-01
Medical image transmission via communication satellite. Evaluation of bone scintigraphy
International Nuclear Information System (INIS)
As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and 93.2#+-#2.4% on the view ...
Energy Technology Data Exchange (ETDEWEB)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 ...
1989-02-01
International Nuclear Information System (INIS)
Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 ...
1989-01-01
Development of gamma-emitting, receptor binding radiotracers for imaging the brain and pancreas
Energy Technology Data Exchange (ETDEWEB)
This progress report covers period from Nov. 1, 1989 to Aug. 31, 1990. The long term objective was to develop receptor-binding radiotracers for SPECT or PET imaging of CNS or peripheral nervous system. The specific chemistry aims, as understood on the basis of past findings, were: to synthesize and develop a more polar analogs of 4IQNB, possessing similar binding characteristics but eliminated more rapidly from the surrounding tissues and the target organ, to design a method of introducing a technetium chelating group onto a molecule or cholinergic agent without drastic lowering of its apparent affinity, to synthesize and develop radiotracers based on m-AChR antagonists selective for one of the subtypes of the receptor. The chemistry service aims were to prepare and characterize (R,R)- and (R,S)-4IQNB and derivatives, to provide the triazene intermediate to other investigators, and to provide ({sup 123}I)4IQNB for in vivo ...
1990-01-01
International Nuclear Information System (INIS)
For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image quality when the inverse ...
2003-08-07
Visualization and volumetric structures from MR images of the brain
Energy Technology Data Exchange (ETDEWEB)
Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows ...
1994-03-01
Expression of bacterial luciferase in eukaryotic cells
International Nuclear Information System (INIS)
Expression of Bacterial luciferase enzyme (lux) in mammalian cells would be a powerful bioreporter protein system for in vivo imaging because eukaryotic luciferases need expensive substrates. However, only a few efforts have been made to express bacterial luciferase enzyme in mammalian cells. As the result of this, we attempted to construct bicistronic vector including two bacterial luciferase genes (LuxA and LuxB) for assessing the potential to be visualized in vitro or in vivo by optical imaging system after transfection to mammalian cells. We designed and synthesized luxA and luxB genes from Photorhabdus Luminescens. To co-express both luxA and luxB genes from a single promoter, we cloned as a bicistronic transcript fused with an internal ribosomal entry site (IRES). This bicistronic transcript was transfected by Superfect to HEK 293T cell line. We also transfected lux A and lux B vector to HEK 293T ...
2005-11-18
Development of Intelligent Setting System for Fracture Based on X-Ray Image
Energy Technology Data Exchange (ETDEWEB)
In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power ...
2006-10-15
Energy Technology Data Exchange (ETDEWEB)
We present the first 3.8 {micro}m image of the dusty ring surrounding the young binary system GG Tau, obtained with the W. M. Keck II 10m telescope's adaptive optics system. THis is the longest wavelength at which the ring has been detected in scattered light so far, allowing a multi-wavelength analysis of the scattering proiperties of the dust grains present in this protoplanetary disk in combination with previous, shorter wavelengths, HST images. We find that the scattering phase function of the dust grains in the disk is only weakly dependent on the wavelength. This is inconsistent with dust models inferred from observations of the interstellar medium or dense molecular clouds. In particular, the strongly forward-throwing scattering phase function observed at 3.8 {micro}m implies a significant increase in the population of large ({approx}> 1 {micro}m) grains, which provides direct ...
2004-02-04
Energy Technology Data Exchange (ETDEWEB)
This paper describes a 1993 field experiment entitled Marine Aerosol Properties and Thermal Imager Performance Trial (MAPTIP) conducted by NATO AC/243 Panel 04/RSG.8 and 04/RSG.5 in the Dutch coastal waters. Objectives were: to improve and validate vertical marine aerosol models by providing an extensive set of aerosol and meteorological measurements, within a coastal environment at different altitudes and for a range of meteorological conditions; make aerosol and meteorological observations in the first 10 m of the ocean surface with a view to extending existing aerosol models to incorporate near-surface effects; and to assess marine boundary layer effects on thermal Imaging systems. Aerosol and meteorological instruments, as well as thermal imagers and calibrated targets, were utilized. This network of instrumentation has provided a comprehensive database of aerosol size distribution profiles and ...
1995-08-01
Real-time monitoring of dosimetry and image quality during digital radiology examinations
International Nuclear Information System (INIS)
Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) ...
2009-12-01
Proceedings of clinical SPECT [single photon emission computed tomography] symposium
International Nuclear Information System (INIS)
It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the ...
1986-09-22
International Nuclear Information System (INIS)
Early white matter (WM) injury affects brain maturation in preterm infants as revealed by diffusion tensor imaging and volumetric magnetic resonance (MR) imaging at term postmenstrual age (PMA). The aim of the study was to assess quantitatively brain maturation in preterm infants with and without milder forms of WM damage (punctate WM lesions, PWML) using conventional MRI. Brain development was quantitatively assessed using a previously validated scoring system (total maturation score, TMS) which utilizes four parameters (progressive myelination and cortical infolding, progressive involution of glial cell migration bands and germinal matrix tissue). PWML were defined as foci of increased signal on T1-weighted images and decreased signal on T2-weighted images with no evidence of cystic degeneration. A group of 22 preterm infants with PWML at term PMA (PWML group) were compared with ...
2007-02-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Energy Technology Data Exchange (ETDEWEB)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression ...
2003-12-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
International Nuclear Information System (INIS)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The ...
2003-12-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
Energy Technology Data Exchange (ETDEWEB)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and ...
1987-04-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
1989-06-01
International Nuclear Information System (INIS)
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...
1989-01-01
International Nuclear Information System (INIS)
Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain ...
2002-09-23
View larger image for ISS022-E-26137 - Earth Sciences and Image ...
The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...
Advances in Imaging of Vertebral and Spinal Cord Injury
UK PubMed Central (United Kingdom)
Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available
2010-04-01
3 - NASA Technical Report Server (NTRS)
performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...
This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)
1990-01-01
Nondestructive characterization of low-level transuranic waste
Energy Technology Data Exchange (ETDEWEB)
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...
1981-10-01
Energy Technology Data Exchange (ETDEWEB)
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography ...
1991-10-02
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within ...
1995-03-11
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within ...
1995-03-01
International Nuclear Information System (INIS)
The present volume on energy and the environment discusses space power requirements, space power systems, space power systems hardware, space radioisotope systems, space solar arrays, space solar cells, space station power, and terrestrial applications of aerospace technology. Attention is given to NASA future space power requirements and issues, the design of a battery charger for the NASA EOS Space Platform, in situ carbon dioxide fixation on Mars, and a preliminary design update of the CRAF/Cassini Power Subsystem. Topics addressed include concentrator testing using projected images, solar power satellites and demonstraton platforms from nonterrestrial materials, a mass sensitivity analysis of lunar orbiting beam power systems, and a power-beaming-based infrastructure for space power. Also discussed are fiber-optic sensors for aerospace electrical measurements, the preliminary ...
1991-08-03
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto ...
2004-12-01
International Nuclear Information System (INIS)
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical ...
Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging
International Nuclear Information System (INIS)
Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...
Energy Technology Data Exchange (ETDEWEB)
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in the vessel was ...
1998-01-01
Review of progress in quantitative NDE. Abstracts
Energy Technology Data Exchange (ETDEWEB)
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...
1986-01-01
Portable fluid X-ray diagnostic system
Energy Technology Data Exchange (ETDEWEB)
A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray sensing means on opposite sides relative to the table member and ...
1989-02-14
Computer image analysis of wear debris for machine condition monitoring and fault diagnosis
Energy Technology Data Exchange (ETDEWEB)
Whenever moving surfaces interact, wear particles are produced. Microscopic examination of the morphology of such wear debris is an accepted method for machine condition monitoring and fault diagnosis. Wear particle analysis has not, however, been widely accepted in industry because it is dependent on expert interpretation of particle morphology and relies on subjective assessment criteria. Consequently, the methods are time consuming and expensive and are not always consistent. The use of automated computer image analysis systems to assess the morphology of debris promises to overcome these limitations by making the methods more time and cost efficient, and also more consistent and effective. The first step required for automation of the analysis procedure is to develop objective criteria for assessing the wear particle morphology. Numerical parameters to describe the morphology have been developed and are outlined in this paper. A ...
1995-03-01
Simple fractal method of assessment of histological images for application in medical diagnostics
UK PubMed Central (United Kingdom)
We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available
Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy
UK PubMed Central (United Kingdom)
In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available
UK PubMed Central (United Kingdom)
This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available
1993-01-01
Adaptive Image Processing A Computational Intelligence Perspective
Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications
2009-01-01
Advances in Modeling of Scanning Charged-Particle-Microscopy Images
Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...
2010-01-01
Three-frame Algorithm of Car Path Reconstruction from Airborne Traffic Data
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
2007-01-01
The state of the art: Appliances
Energy Technology Data Exchange (ETDEWEB)
This original volume of the Appliances Atlas includes discussion of residential appliances, commercial refrigeration and cooking, and office equipment. (The residential appliances section has since been updated in the E Source 1994 Residential Appliances Technology Atlas.) The commercial refrigeration section contains details on efficiency opportunities through load reduction and mechanical system improvements, while commercial cooking covers improvements to electric and gas fryers, griddles, ovens, cooktops, broilers, and steam equipment. The office equipment section offers discussion of trends and energy use of computers and their components, imaging technologies, and communication equipment. (Published under the former name, Competitek.)
1990-12-31
The AMS-02 electromagnetic calorimeter
The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).
2002-01-01
Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report
Energy Technology Data Exchange (ETDEWEB)
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
1992-03-01
Soft x-ray microradiography and lithograph using a laser produced plasma source
Energy Technology Data Exchange (ETDEWEB)
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
1992-01-01
PLZT electrooptic shutters: applications
Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.
1975-08-01
Laser ray-tracing method for optical testing.
We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906
1999-07-15
FADC signal reconstruction for the MAGIC telescope
Energy Technology Data Exchange (ETDEWEB)
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
2008-09-11
International Nuclear Information System (INIS)
The goals of this paper are to describe the fabrication and complete evaluation of a dihydropyridine <- -> pyridinium salt type redox system for the delivery of radioiodinated agents to the brain. Tissue distribution studies of "1"2"5I-labeled 4-iodoaniline and the redox agents were performed in rats. ["1"2"5I]Iodoaniline initially showed moderate brain uptake with subsequent release of the radioactivity from the brain. ["1"2"5I]Iodoaniline, however, when coupled to a dihydropyridine carrier showed significantly higher uptake and retention in the brain. (author).
Magnetic resonance imaging in childhood epilepsy
International Nuclear Information System (INIS)
The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.
Esters useful as brain imaging agents
Energy Technology Data Exchange (ETDEWEB)
Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.
1981-08-18
Esters useful as brain imaging agents
International Nuclear Information System (INIS)
Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.
Amides useful as brain imaging agents
Energy Technology Data Exchange (ETDEWEB)
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula
1981-07-21
Amides useful as brain imaging agents
International Nuclear Information System (INIS)
Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.
Energy Technology Data Exchange (ETDEWEB)
Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm nano particles, which will make filter mass based PM control very challenging in the near future. One result was that gravimetric PM emission could ...
2006-10-15
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images ...
2000-12-01
Demonstration of realtime radiography on pipeline girth welds: Final report
Energy Technology Data Exchange (ETDEWEB)
Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray ...
1988-09-01
Chapter 14: Seismic imaging using 2- and 3-D migration
Energy Technology Data Exchange (ETDEWEB)
Development of a number of original 3-D migration methods and algorithms is described. The computational efficiency of these algorithms is demonstrated by implementing them on vector and parallel supercomputers. Two-dimensional post-stack and pre-stack depth migration algorithms in the frequency - space domain using implicit finite difference method were also developed and implemented on a parallel computer, and adapted for applications that range from deep crustal imaging of seismic wavefields that involve wide ranging travel times and frequencies. All implicit finite difference migration algorithms were highly prallelized . The one pass 3-D post-stack depth migration algorithm was extensively used for imaging of seismic monitoring data from Cold Lake, Alberta. Experience shows that it provides the right trade-off between accuracy and computational efficiency. A new formulation of the 3-D reverse-time migration method was developed using ...
1999-09-01
APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs
Energy Technology Data Exchange (ETDEWEB)
A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified ...
1992-07-01
Image-enhancement applications at the Lawrence Livermore National Laboratory
Energy Technology Data Exchange (ETDEWEB)
A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to ...
1996-08-01
Self-assessment of current knowledge in nuclear medicine (second edition)
Energy Technology Data Exchange (ETDEWEB)
In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the ...
1981-01-01
Monitoring the effect of chemotherapy in Ewing's sarcoma of bone with MR imaging
International Nuclear Information System (INIS)
Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff ...
A novel method to characterize the MTF in 3D for computed mammotomography
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...
2006-03-01
Surgical navigation using audio feedback.
Current medical visualization technology intended for positional guidance in surgical applications may only ever have limited utility in the operating room due to the preexisting visual requirements of surgical practice. Additionally, visual systems impose limits as a result of their high latency, poor image resolution, problems with stereopsis and physical strain upon the user. Audio technology is relatively unexamined in the broad range of available methodologies for medical devices. The potential to translate surgical instrument position into audio feedback presents a novel solution to the human factors and engineering problems faced by visual display technology because audio technology employs a rich and as yet unburdened sensory modality. We describe an experimental system we have developed for investigating this new interface design approach using commercially available hardware. PMID:10173065
1997-01-01
STAR: a local network system for real-time management of imagery data
Energy Technology Data Exchange (ETDEWEB)
Overall architecture of a local computer network, STAR, is described. The objective is to accomplish a cost-effective system which provides multiple users a real-time service of manipulating very large volume imagery information and data. STAR consists of a reconfigurable communication subnet (starnet), heterogeneous resource units, and distributed-control software entities. Architectural aspects of a fault-tolerant communication subnet, distributed database management, and a distributed scheduling strategy for configuring desirable computation topology are exploited. A model for comparing cost-effectiveness among starnet, crossbar, and multiple buses is included. It is concluded that starnet outperforms the other two when the number of units to be connected is larger than 64. This project serves as a research tool for using current and projected technology to innovate better schemes for parallel image processing. 30 references.
1982-10-01
Road Interpretation for Driver Assistance Based on an Early Cognitive Vision System
DEFF Research Database (Denmark)
In this work, we address the problem of road interpretation for driver assistance based on an early cognitive vision system. The structure of a road and the relevant traf?c are interpreted in terms of ego-motion estimation of the car, independently moving objects on the road, lane markers and large scale maps of the road. We make use of temporal and spatial disambiguation mechanisms to increase the reliability of visually extracted 2D and 3D information. This information is then used to interpret the layout of the road by using lane markers that are detected via Bayesian reasoning. We also estimate the ego-motion of the car which is used to create large scale maps of the road and also to detect independently moving objects. Sample results for the presented algorithms are shown on a stereo image sequence, that has been collected from a structured road.
2009-01-01
Recursive neural networks for processing graphs with labelled edges: theory and applications.
In this paper, we introduce a new recursive neural network model able to process directed acyclic graphs with labelled edges. The model uses a state transition function which considers the edge labels and is independent both from the number and the order of the children of each node. The computational capabilities of the new recursive architecture are assessed. Moreover, in order to test the proposed architecture on a practical challenging application, the problem of object detection in images is also addressed. In fact, the localization of target objects is a preliminary step in any recognition system. The proposed technique is general and can be applied in different detection systems, since it does not exploit any a priori knowledge on the particular problem. Some experiments on face detection, carried out on scenes acquired by an indoor camera, are reported, showing very promising results. PMID:16181770
2005-09-21
Protoplanetary Disks of Binary Systems in Orion
Dusty primordial disks surrounding young low-mass stars are revealing tracers of stellar and planetary formation. The evolution and lifetime of these disks define the boundary conditions of the mechanisms of planet formation. Stellar companions, however, can significantly change this evolution through their tidal interactions. Stellar evolution and planet formation in binaries have to respond to an environment of truncated, quickly disappearing disks--very different compared to an isolated star environment. In order to investigate details of the influence of binarity on circumstellar disk evolution, we obtained adaptive optics supported near-infrared imaging and spectroscopy of the individual components of 22 low-mass binaries in the well-known Orion Nebula Cluster. Brackett gamma emission, which we detect in several systems, is used as a tracer for the presence of an active accretion disk around each binary component. We find a low fraction of ...
2010-01-01
We present a new modular traffic signs recognition system, successfully applied to both American and European speed limit signs. Our sign detection step is based only on shape-detection (rectangles or circles). This enables it to work on grayscale images, contrary to most European competitors, which eases robustness to illumination conditions (notably night operation). Speed sign candidates are classified (or rejected) by segmenting potential digits inside them (which is rather original and has several advantages), and then applying a neural digit recognition. The global detection rate is ~90% for both (standard) U.S. and E.U. speed signs, with a misclassification rate 150 minutes of video. The system processes in real-time ~20 frames/s on a standard high-end laptop.
2009-01-01
Mental health in patients with systemic sclerosis: a controlled investigation
British Library Electronic Table of Contents (United Kingdom)
Abstract Background Despite the undeniable impact of systemic sclerosis (SS) on quality of life, only a few studies so far have focused on its psychiatric or psychological aspects. We aimed at assessing psychiatric symptoms and self-image in inpatients with SS and comparing them with patients with either a very mild skin condition or a serious skin condition. Methods Three groups were recruited: (i) 38 consecutive female inpatients with SS; (ii) 38 age-matched female outpatients with melanocytic naevi; (iii) 35 age-matched female inpatients with melanoma. All participants completed the Zung Anxiety Scale, the Zung Depression Scale and a self-report questionnaire measuring self-perceived personal qualities. Patients with SS were also clinically interviewed by a psychologist. Results The cli...
2008-01-01
Local Electrostatic Moments and Periodic Boundary Conditition
Energy Technology Data Exchange (ETDEWEB)
Electronic structure calculations frequently invoke periodic boundary conditions to solve for electrostatic potentials. For systems that are electronically charged, or contain dipole (or higher) moments, this artifice introduces spurious potentials due to the interactions between the system and multipole moments of its periodic images in aperiodic directions. I describe a method to properly handle the multipole moments of the electron density in electronic structure calculations using periodic boundary conditions. The density for which an electrostatic potential is to be evaluated is divided into two pieces. A local density is constructed that matches the desired moments of the full density, and its potential computed treating this density as isolated. With the density of this local moment countercharge removed from the full density, the remainder density lacks the troublesome moments and its electrostatic potential can be ...
1998-12-04
Development of a new #gamma#-ray detector for PEM applications
International Nuclear Information System (INIS)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
2007-05-01
Absorbed dose and dose reduction in mammography
International Nuclear Information System (INIS)
First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Theoretical and experimental data which have defined and/or extended the effectiveness of remote sensing operations are explored, with consideration given to both scientific and commercial activities. The remote sensing of soil moisture, the sea surface, and oil slicks is discussed, as are programs using satellites for studying geodynamics and geodesy, currents and waves, and coastal zones. NASA, Canadian, and Japanese radar and microwave passive and active systems are described, together with algorithms and techniques for image processing and classification. The SAR-580 project is outlined, and attention is devoted to satellite applications in investigations of the structure of the atmosphere, agriculture and land use, and geology. Design and performance features of various optical scanner, radar, and multispectral data processing systems and procedures are detailed.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The main objective of this dissertation is to build a numerical 3D geological model of a turbidite reservoir using well and seismic data. For the, the first step was to elaborate a depositional model using a high-resolution genetic stratigraphy approach. Simultaneously, the stratigraphic inversion over the seismic data resulted in an optimal acoustic impedance model. Both models, were used to build, by geostatistical methods, a 3-D geological model, which represents the spatial distribution of the reservoir facies. The studied case is the late Cretaceous Namorado turbidite system in the Campos basin, which is the reservoir of the Namorado oil field, located 80 km from the Brazilian coast, under a bathymetry between 110 and 250 m. The reservoir is a turbidite succession with 90 to 180 m thickness. It is composed by sand-supported conglomerates, matrix-supported conglomerate, massive sandstones, shales, marls and limestones. Four lithotypes characterise the main ...
1997-01-29
International Nuclear Information System (INIS)
To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to ...
Application of neutron radiography systems in JRR-3M to nuclear engineering
Energy Technology Data Exchange (ETDEWEB)
Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Encapsulation of technetium-99m sestamibi ({sup 99m}Tc-MIBI) in polyethyleneglycol-liposomes ({sup 99m}Tc-MIBI-PEG-liposomes) could extend the duration of its circulation in blood and alter its biodistribution, enabling its concentration in tumours to be increased. An original method to encapsulate {sup 99m}Tc-MIBI in PEG-liposomes is described. The {sup 99m}Tc-MIBI-PEG-liposomes were compared with free {sup 99m}Tc-MIBI with respect to (a) tumour availability (b) ability to distinguish between chemotherapy-sensitive and -resistant cells and (c) uptake ratio in tumour imaging. PEG-liposomal systems composed of distearoylphosphatidylcholine/cholesterol/PEG{sub 2000}-distearoyl phosphatidylethanolamine and lissamine-rhodamine B-labelled liposomes were used. The encapsulation of {sup 99m}Tc-MIBI in liposomes was achieved using the K{sup +} diffusion potential method. We compared the uptake of free versus encapsulated {sup 99m}Tc-MIBI by sensitive ...
2003-04-01
ALOS satellite imagery utilizations for safeguards
International Nuclear Information System (INIS)
This paper introduces examples of satellite imageries analysis and utilizations for safeguards activities. Recently, many kinds of satellite imageries are available in the world i.e., high-spatial resolution, multi- and hyper-spectral, multi-function, and multi-polarization radars. The problem is that how to obtain the required information from these digital images. The Japan Aerospace Exploration Agency (JAXA) has successfully launched the Advanced Land Observing Satellite (ALOS, the nickname is 'Daichi') on 24th January, 2006. The mission objectives are cartography, regional observation, disaster monitoring etc. ALOS has three instruments, PRISM, AVNIR-2, and PALSAR, to achieve these objectives. An overview of ALOS is provided. ALOS follows the Japanese Earth Resources Satellite- 1 (JERS-1) and the Advanced Earth Observing Satellite (ADEOS) and utilizes advanced land-observing technology. ALOS is fling in a Sun-synchronous orbit with an inclination angle of 98.16 ...
2006-10-16
Multi-wavelength observations of the young binary system Haro 6-10: The case of misaligned discs
Context. We present a multi-wavelength, high-resolution observational survey of the young binary system Haro 6-10 (GV Tau, IRAS 04263+2426), which is harbouring one of the few known infrared companions. Aims. The primary goal of this project is to determine the physical and geometrical properties of the circumstellar and circumbinary material in the Haro 6-10 system. Methods. High-resolution optical (HST/WFPC2) and near-infrared (VLT/NACO) images in different bands were analysed to investigate the large-scale structures of the material around the binary.Mid-infrared interferometry (VLTI/MIDI) and spectroscopy (TIMMI2 at the 3.6m ESO telescope) were carried out to determine the structure and optical depth of the circumstellar material around the individual components. Results. The multi-wavelength observations suggest that both components of the binary system Haro 6-10 are embedded in a common envelope. ...
2011-01-01
International Nuclear Information System (INIS)
Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography ...
2003-02-01
Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy
Energy Technology Data Exchange (ETDEWEB)
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential ...
1997-04-01
The Star Clusters in the Irregular Galaxy NGC 4449
We examine the star clusters in the irregular galaxy NGC 4449. We use a near-infrared spectrum and broad-band images taken with the HST to place a limit of 8--15 Myrs on the age of the bright central ojbect in NGC 4449. Its luminosity and size suggest that it is comparable to young super star clusters. However, there is a peculiar nucleated-bar structure at the center of this star cluster, and we suggest that this structure is debris from the interaction that has produced the counter-rotating gas systems and extended gas streamers in the galaxy. From the images we identify 60 other candidate compact star clusters in NGC 4449. Fourteen of these could be background elliptical galaxies or old globular star clusters. Of the star clusters, three, in addition to the central object, are potentially super star clusters, and many others are comparable to the populous clusters found in the LMC. The star clusters span a large range in ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the ...
1986-07-01
This paper presents new images and spectroscopy of NGC 34 (Mrk 938) obtained with the du Pont 2.5-m and Baade 6.5-m telescopes at Las Campanas, plus photometry of an HST archival V image. This Mv = -21.6 galaxy has often been classified as a Seyfert 2, yet recently published infrared spectra suggest a dominant central starburst. We find that the galaxy features a single nucleus, a main spheroid containing a blue central disk, and tidal tails indicative of two former disk galaxies. These galaxies appear to have completed merging. The remnant shows three clear optical signs that the merger was gas-rich ("wet") and accompanied by a starburst: (1) It sports a rich system of young star clusters, of which 87 have absolute magnitudes -10.0 > Mv > -15.4. Five clusters with available spectra have ages in the range 0.1-1.0 Gyr, photometric masses between 2x10^6 and 2x10^7 Msun, and are gravitationally bound young globulars. (2) ...
2007-01-01
International Nuclear Information System (INIS)
The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to ...
1983-01-01
PET/MRI hybrid imaging: devices and initial results
International Nuclear Information System (INIS)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...
2008-06-01
International Nuclear Information System (INIS)
This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative algorithms, compared with the situation when a ...
2005-09-01
Energy Technology Data Exchange (ETDEWEB)
The authors will be conducting an integrated seismic experiment to image the structure of the crust and upper mantle of northern California immediately before and after passage of the Mendocino Triple Junction. The purpose of this representation is to describe the project to other scientists interested in geological and geophysical processes in this region and to solicit input relevant to detailed siting of the funded seismic profiles. The experiment encompasses two field seasons: onshore seismic refraction/wide angle reflection data acquisition along three long profiles scheduled for late summer, 1993; and MCS deep crustal seismic reflection data acquisition accompanied by simultaneous large aperture recording using both ocean bottom and onshore seismographs, tentatively scheduled for summer, 1994. This study represents a component of a long-term, multi-disciplinary effort on the part of many investigators to exploit this well defined system ...
1993-04-01
Evolution of virtual CT laparoscopy for preoperative imaging in laparoscopic cholecystectomy
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that our new technique may contribute to the ...
2002-06-01
Binary mass transfer via Roche-lobe overflow (RLOF) is a key channel for producing stripped-envelope Wolf-Rayet (WR) stars and may be critical to account for SN Ib/c progenitors. RY Scuti is an extremely rare example of a massive binary star caught in this brief but important phase. Its toroidal nebula indicates equatorial mass loss during RLOF, while the mass-gaining star is apparently embedded in an opaque accretion disk. RY Scuti's toroidal nebula has two components: an inner ionised double-ring system, and an outer dust torus that is twice the size of the ionised rings. We present two epochs of Lband Keck NGS-AO images of the dust torus, plus three epochs of HST images of the ionised gas rings. Proper motions show that the inner ionised rings and the outer dust torus came from two separate ejection events roughly 130 and 250 yr ago. This suggests that RLOF in massive contact binaries can be accompanied by eruptive and ...
2011-01-01
Compressed-shell integrity measurements in spherical implosion experiments
International Nuclear Information System (INIS)
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of ...
2001-06-01
Blunt renal trauma in children: healing of renal injuries and recommendations for imaging follow-up
International Nuclear Information System (INIS)
Initial CT grading of renal injury was correlated with the frequency of complications and the time course of healing in 35 children. All renal contusions (grade 1, 8) and small parenchymal lacerations (grade 2, 8) healed without complications. All lacerations extending to the collecting system (grade 3, 9) resulted in mild to severe loss of renal function with progressive healing over 4 months. One of four segmental infarcts (grade 4 A), and five of six vascular pedicle injuries (grade 4 B) resulted in severe loss of renal function. Complications, including urinoma (2), sepsis (1), hydronephrosis (1), and persistent hypertension (2), were limited to grade 3 and 4 injuries. Our results suggest that mild renal injuries do not require follow-up imaging. Major renal lacerations and vascular pedicle injuries, however, often result in loss of renal function and should be followed up closely due to the risk of delayed complications. Follow-up ...
Automated synthesis of hypoxia imaging agent [18F]FMISO based upon a modified Explora FDG4 module
British Library Electronic Table of Contents (United Kingdom)
A new automated synthesis procedure of 1-H-1-(3-[18F]fluoro-2-hydroxypropyl)-2-nitroimidazole ([18F]FMISO), a specific hypoxia imaging agent with great significances for the noninvasive, dynamic hypoxia evaluation of cancer, was developed by modifying Explora FDG4 module, a commercial [18F]FDG production system, in this study. Its radiochemical synthesis was carried out via two sequent reaction steps, i.e. the nucleophilic displacement of labeling precursor 1-(2?-nitro-1?-imidazolyl)-2-O-tetrahydropyranyl-3-O-tosyl-propaned iol (NITTP) with activated 18F- ion at 100 ?C for 8 minutes, and the following hydrolysis with 1M HCl at 100 ?C for 5 minutes and neutralization with 1M NaOH. Two-pot reaction with two independent separations was adopted to assure the good separation of final product vi...
2009-01-01
Applications with a new low-temperature UHV STM at 5 K
International Nuclear Information System (INIS)
A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs below a transition ...
1998-03-01
An Upper Limit on the Albedo of HD 209458b: Direct Imaging Photometry with the MOST Satellite
We present space-based photometry of the transiting exoplanetary system HD 209458 obtained with the MOST (Microvariablity and Oscillations of STars) satellite, spanning 14 days and covering 4 transits and 4 secondary eclipses. The HD 209458 photometry was obtained in MOST's lower-precision Direct Imaging mode, which is used for targets in the brightness range $6.5 < V < 13$. We describe the photometric reduction techniques for this mode of observing, in particular the corrections for stray Earthshine. We do not detect the secondary eclipse in the MOST data, to a limit in depth of 0.053 mmag (1 \\sigma). We set a 1 \\sigma upper limit on the planet-star flux ratio of 4.88 x 10^-5 corresponding to a geometric albedo upper limit in the MOST bandpass (400 to 700 nm) of 0.25. The corresponding numbers at the 3 \\sigma level are 1.34 x 10^-4 and 0.68 respectively. HD 209458b is half as bright as Jupiter in the MOST bandpass. This low geometric ...
2006-01-01
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the ...
2007-08-21
An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste
International Nuclear Information System (INIS)
The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...
2007-08-21
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an ...
2004-09-01
Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR
International Nuclear Information System (INIS)
Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience ...
2009-07-01
Radioisotope imaging of brain tumors in two rhesus monkeys. Final report
Energy Technology Data Exchange (ETDEWEB)
Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.
1988-04-01
Fracture imaging with converted elastic waves
Energy Technology Data Exchange (ETDEWEB)
This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).
2001-05-29
The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries
UK PubMed Central (United Kingdom)
The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available
2010-01-01
Selective imaging of adherent targeted ultrasound contrast agents
UK PubMed Central (United Kingdom)
The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available
2007-04-21
Radionuclide imaging of the acutely painful scrotum
International Nuclear Information System (INIS)
This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.
UK PubMed Central (United Kingdom)
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
2008-04-01
UK PubMed Central (United Kingdom)
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
2008-09-01
Nonnegative Factorization of Diffusion Tensor Images and Its Applications
UK PubMed Central (United Kingdom)
This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
2010-06-07
MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT
UK PubMed Central (United Kingdom)
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
2009-09-01
Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging
UK PubMed Central (United Kingdom)
Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
2010-09-01
Imaging of calcium transients in skeletal muscle fibers.
UK PubMed Central (United Kingdom)
Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available
1991-01-01
Diagnostic quality of low resolution images for tele-woundcare.
UK PubMed Central (United Kingdom)
The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available
1998-01-01
UK PubMed Central (United Kingdom)
Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available
2008-10-01
Comparative evaluation of similarity measures for the rigid registration of multi-modal head images
Energy Technology Data Exchange (ETDEWEB)
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...
2007-09-21
Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy
UK PubMed Central (United Kingdom)
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
2009-07-20
An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia
UK PubMed Central (United Kingdom)
ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available
2010-07-01
A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
UK PubMed Central (United Kingdom)
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
2010-01-01
The safety issues of medical robotics
International Nuclear Information System (INIS)
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed ...
2001-08-01
Energy Technology Data Exchange (ETDEWEB)
Three aspects of the research project ``Surface physics with cold and ultracold neutron reflectometry`` were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow ``pencil beam`` analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both ...
1991-11-01
Surface physics with cold and thermal neutron reflectometry
Energy Technology Data Exchange (ETDEWEB)
Three aspects of the research project Surface physics with cold and ultracold neutron reflectometry'' were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow pencil beam'' analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the ...
1991-11-01
Real-time 3-D SAFT-UT system evaluation and validation
International Nuclear Information System (INIS)
SAFT-UT technology is shown to provide significant enhancements to the inspection of materials used in US nuclear power plants. This report provides guidelines for the implementation of SAFT-UT technology and shows the results from its application. An overview of the development of SAFT-UT is provided so that the reader may become familiar with the technology. Then the basic fundamentals are presented with an extensive list of references. A comprehensive operating procedure, which is used in conjunction with the SAFT-UT field system developed by Pacific Northwest Laboratory (PNL), provides the recipe for both SAFT data acquisition and analysis. The specification for the hardware implementation is provided for the SAFT-UT system along with a description of the subsequent developments and improvements. One development of technical interest is the SAFT real time processor. Performance of the real-time processor is impressive and comparison is made ...
1993-05-17
4U 1907+09: a HMXB running away from the Galactic plane
We report the discovery of a bow shock around the high-mass X-ray binary (HMXB) 4U 1907+09 using the Spitzer Space Telescope 24 $\\mu$m data (after Vela X-1 the second example of bow shocks associated with HMXBs). The detection of the bow shock implies that 4U 1907+09 is moving through the space with a high (supersonic) peculiar velocity. To confirm the runaway nature of 4U 1907+09, we measured its proper motion, which for an adopted distance to the system of 4 kpc corresponds to a peculiar transverse velocity of $\\simeq 160 \\pm 115$ km/s, meaning that 4U 1907+09 is indeed a runaway system and supporting the general belief that most of HMXBs possess high space velocities. The direction of motion of 4U 1907+09 inferred from the proper motion measurement is consistent with the orientation of the symmetry axis of the bow shock, and shows that the HMXB is running away from the Galactic plane. We also present the Spitzer ...
2011-01-01
0--30 keV low-energy focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
1988-05-01
0--30 keV low-energy focused ion beam system
International Nuclear Information System (INIS)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy
International Nuclear Information System (INIS)
Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or ...
1990-08-26
International Nuclear Information System (INIS)
The implementation of wind energy conversion systems in the built environment renewed the interest and the research on Vertical Axis Wind Turbines (VAWT), which in this application present several advantages over Horizontal Axis Wind Turbines (HAWT). The VAWT has an inherent unsteady aerodynamic behavior due to the variation of angle of attack with the angle of rotation, perceived velocity and consequentially Reynolds number. The phenomenon of dynamic stall is then an intrinsic effect of the operation of a Vertical Axis Wind Turbine at low tip speed ratios, having a significant impact in both loads and power. The complexity of the unsteady aerodynamics of the VAWT makes it extremely attractive to be analyzed using Computational Fluid Dynamics (CFD) models, where an approximation of the continuity and momentum equations of the Navier-Stokes equations set is solved. The complexity of the problem and the need for new design approaches for VAWT for the built ...
2007-07-01
Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter
Energy Technology Data Exchange (ETDEWEB)
Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in ...
2002-06-01
Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone
Energy Technology Data Exchange (ETDEWEB)
Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal association cortex) ...
1995-06-19
Energy Technology Data Exchange (ETDEWEB)
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and argon lines can be ...
1997-10-01
Post-mortem fetal MRI: What do we learn from it?
International Nuclear Information System (INIS)
Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.
2006-02-01
Future of X-ray phase imaging in medical imaging technology
International Nuclear Information System (INIS)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
2007-04-01
RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION
International Nuclear Information System (INIS)
We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z ...
2009-04-10
International Nuclear Information System (INIS)
Accurate modeling of system response and scatter distribution is crucial for image reconstruction in emission tomography. Monte Carlo simulations are very well suited to calculate these quantities. However, Monte Carlo simulations are also slow and many simulated counts are needed to provide a sufficiently exact estimate of the detection probabilities. In order to overcome these problems, we propose to split the simulation into two parts, the detection system and the object to be imaged (the patient). A so-called 'virtual boundary' that separates these two parts is introduced. Within the patient, particles are simulated conventionally. Whenever a photon reaches the virtual boundary, its detection probability is calculated analytically by evaluating a multi-dimensional B-spline that depends on the photon position, direction and energy. The unknown B-spline knot values that define this B-spline are fixed ...
2010-06-21
International Nuclear Information System (INIS)
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
1999-11-03
Upper Limits from HESS Observations of AGN in 2005-2007
Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.
2007-01-01
Transverse Imaging of the Proton in Exclusive Diffractive pp Scattering
Energy Technology Data Exchange (ETDEWEB)
In a forthcoming paper we describe a new approach to rapidity gap survival (RGS) in the production of high-mass systems (H = dijet, Higgs, etc.) in exclusive double-gap diffractive pp scattering, pp -> p + H + p. It is based on the idea that hard and soft interactions are approximately independent (QCD factorization), and allows us to calculate the RGS probability in a model-independent way in terms of the gluon generalized parton distributions (GPDs) in the colliding protons and the pp elastic scattering amplitude. Here we focus on the transverse momentum dependence of the cross section. By measuring the ''diffraction pattern'', one can perform detailed tests of the interplay of hard and soft interactions, and even extract information about the gluon GPD in the proton from the data.
2006-04-20
The LSST Data Mining Research Agenda
We describe features of the LSST science database that are amenable to scientific data mining, object classification, outlier identification, anomaly detection, image quality assurance, and survey science validation. The data mining research agenda includes: scalability (at petabytes scales) of existing machine learning and data mining algorithms; development of grid-enabled parallel data mining algorithms; designing a robust system for brokering classifications from the LSST event pipeline (which may produce 10,000 or more event alerts per night); multi-resolution methods for exploration of petascale databases; indexing of multi-attribute multi-dimensional astronomical databases (beyond spatial indexing) for rapid querying of petabyte databases; and more.
2008-01-01
Smoothing of laser energy deposition by gas jets
International Nuclear Information System (INIS)
Smoothing of laser beam non-uniformities using gas jets has been studied. The experiment has been performed with the PALS (Prague Asterix Laser System) laser working at 0.44 ?m with an intensity of about 1015 W/cm2. The laser beam has been split in two by a prism thus creating an artificial large-scale non-uniformity (? 90 ?m). We recorded time resolved and static images of laser-gas jet interaction with and without an Al target. Multi 1-dimensional and 2-dimensional simulations show that such interaction acts redistributing the over-intensities over larger surface. This effect has to be attributed to ionization processes with consequent laser beam refraction. Results show that Argon gas jet produces a strong refraction of the laser beam thus strongly reducing the initial two spots separation. (authors)
2009-08-01
Retinue of the beans roots growth by using neutron radiography technique
International Nuclear Information System (INIS)
Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)
2002-08-11
International Nuclear Information System (INIS)
The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.
2006-01-01
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Phase formation sequence in the Pd-GaAs system
Energy Technology Data Exchange (ETDEWEB)
The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.
1985-12-01
ON THE PROGENITOR AND EARLY EVOLUTION OF THE TYPE II SUPERNOVA 2009kr
International Nuclear Information System (INIS)
We identify a source coincident with SN 2009kr in Hubble Space Telescope pre-explosion images. The object appears to be a single point source with an intrinsic color V - I = 1.1 #+-# 0.25 and M_V = -7.6 #+-# 0.6. If this is a single star, it would be a yellow supergiant of log L/L _s_u_n #approx# 5.1 and a mass of 15"+"5 _-_4 M _s_u_n. The spatial resolution does not allow us yet to definitively determine if the progenitor object is a single star, a binary system, or a compact cluster. We show that the early light curve is similar to a Type IIL SN, but the prominent H#alpha# P-Cygni profiles and the signature of the end of a recombination phase are reminiscent of a Type IIP. The evolution of the expanding ejecta will play an important role in understanding the progenitor object.
2010-05-10
Monitoring urban land cover and vegetation change by multi-temporal remote sensing information
British Library Electronic Table of Contents (United Kingdom)
In order to analyze changes in human settlement in Xuzhou city during the past 20 years, changes in land cover and vegetation were investigated based on multi-temporal remote sensing Landsat TM images. We developed a hierarchical classifier system that uses different feature inputs for specific classes and conducted a classification post-processing approach to improve its accuracy. From our statistical analysis of changes in urban land cover from 1987 to 2007, we conclude that built-up land areas have obviously increased, while farmland has seen in a continuous loss due to urban growth and human activities. A NDVI difference approach was used to extract information on changes in vegetation. A false change information elimination approach was developed based on prior knowledge and statistic...
2010-01-01
Gravity Dual for a Model of Perception
One of the salient features of human perception is its invariance under dilatation in addition to the Euclidean group, but its non-invariance under special conformal transformation. We investigate a holographic approach to the information processing in image discrimination with this feature. We claim that a strongly coupled analogue of the statistical model proposed by Bialek and Zee can be holographically realized in scale invariant but non-conformal Euclidean geometries. We identify the Bayesian probability distribution of our generalized Bialek-Zee model with the GKPW partition function of the dual gravitational system. We provide a concrete example of the geometric configuration based on a vector condensation model coupled with the Euclidean Einstein-Hilbert action. From the proposed geometry, we study sample correlation functions to compute the Bayesian probability distribution.
2010-01-01
Gravitational Lens Modeling with Genetic Algorithms and Particle Swarm Optimizers
Strong gravitational lensing of an extended object is described by a mapping from source to image coordinates that is nonlinear and cannot generally be inverted analytically. Determining the structure of the source intensity distribution also requires a description of the blurring effect due to a point spread function. This initial study uses an iterative gravitational lens modeling scheme based on the semilinear method to determine the linear parameters (source intensity profile) of a strongly lensed system. Our 'matrix-free' approach avoids construction of the lens and blurring operators while retaining the least squares formulation of the problem. The parameters of an analytical lens model are found through nonlinear optimization by an advanced genetic algorithm (GA) and particle swarm optimizer (PSO). These global optimization routines are designed to explore the parameter space thoroughly, mapping model degeneracies in detail. We develop a ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Petrographical analysis is a microscopical analytical tool which allows definition of the exact nature of the components of different concrete mixes, as well as definition of internal structures and alteration processes. In order to improve the precision and the swiftness of the petrographical analysis, an automated image analysis system has been developed. In the next stage of this study, which consisted in the testing of new concrete mixes containing fluidised bed ashes, petrography has been used, not only to identify the nature of the mix components, but also assess the behaviour of these new concrete mixes when exposed to aggressive conditions.
1997-11-01
British Library Electronic Table of Contents (United Kingdom)
A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.
2011-01-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.
2003-06-01
A Detector for 2-D Neutron Imaging for the Spallation Neutron Source
Energy Technology Data Exchange (ETDEWEB)
Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)
2006-07-01
Typhoon Aere : Image of the Day - NASA Earth Observatory
Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...
The importance of radiation quality for optimisation in radiology
UK PubMed Central (United Kingdom)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469
Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner
1993-01-01
Imaging subsurface using cross-correlation
Energy Technology Data Exchange (ETDEWEB)
This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.
1997-12-31
Image Analysis and Computer Vision: 1996.
... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...
1997-01-01
Histopathological Image Analysis: A Review
UK PubMed Central (United Kingdom)
Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available
2009-01-01
Design of a new serotonin receptor 5-HT_1_A imaging agent based on "9"9"mTc
International Nuclear Information System (INIS)
Serotonin is one of the neurotransmitters found in the brain and mediates brain functions. It is very well known that serotonin related brain abnormalities are exerted mainly via serotonin receptors in a similar manner to other neurotransmitters found in the brain. Recently, it has also been found that serotonin is involved in Alzheimer's disease either directly or indirectly by its actions on serotonergic neurons. To understand and treat the diseases caused by abnormalities in the serotonergic system in the brain, it is certain that its mechanism of function has to be well investigated. So far several 5-HT receptors and receptor subtypes have been well characterized. Moreover, serotonin agonists and antagonists acting on specific receptors are chemically synthesized and are now available for the prevention or treatment of serotonergic related diseases. In recent years, a great demand for developing neuroimaging agents has emerged for the diagnosis of abnormal ...
2004-07-01
Grate monitoring systems, state of the art; Metoder foer rosteroevervakning, dagslaegesbestaemning
Energy Technology Data Exchange (ETDEWEB)
During a number of years research and development projects have been made to present methods of monitoring the grate in a grate fired boiler. The monitoring is interesting in order to be able to increase efficiency, increase burn-out of ash, improve the status of emissions, improve transportation of ash and fuel through the furnace, reduce costs for operation and maintenance, handle greater loads etc. Improvement of the combustion has been concentrated to the development of the gas phase combustion. In the past few years the computer development has progressed rapidly and the use of optical monitoring methods have been made possible for monitoring grates. To analyse state of the art of optical grate monitoring systems three different methods have been used, literature search, inquiry where plant owners were asked if they have used grate monitoring systems and if so what experiences they have, and interviews with scientists and users. The ...
2001-01-01
Combining anatomy and function: the path to true image fusion
Energy Technology Data Exchange (ETDEWEB)
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
2001-10-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: Patients with the tested ...
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die ...
1997-12-01