WorldWideScience
 
 
1

DNA replication in Escherichia coli mutants that lack protein HU.  

UK PubMed Central (United Kingdom)

DNA replication in Escherichia coli cells lacking protein HU was studied. HU has been suggested to be involved in the initiation of replication from in vitro studies. The isolated HU mutants, however,...Full Text Available

1989-10-01

2

ff44.img  

Science.gov (United States)

... \\O]`\\:UTIQJVaW\\UT`FObWOf_[[a`_aZamqpZf[bhmg]bnVO]qreZioa_Kg[I_dSVYWLW\\` copyng[ZW^qlmys{xalu|? hu|sjsmgromp???vj?}{n\\wtoddSw`]V`afTW}?{mqRfe`[ajf? ...

3

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

4

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

5

LOC387715/HTRA1 gene polymorphisms and susceptibility to age-related macular degeneration: A HuGE review and meta-analysis  

UK PubMed Central (United Kingdom)

PurposeTo examine the association of age-related macular degeneration (AMD) with HtrA serine peptidase 1 (HTRA1) gene rs11200638 G→A polymorphism and LOC387715/...Full Text Available

6

Higgs Chaotic Inflation  

CERN Document Server

We construct a chaotic inflation model in which the Higgs fields play the role of the inflaton in the singlet extension of the supersymmetric standard model. The key idea is to impose a shift symmetry on the D-flat direction Hu Hd in the Kahler potential. The model is a realization of the recently proposed running kinetic inflation, in which the coefficient of the kinetic term grows as the inflaton field. The inflaton potential depends on the structure of the Higgs sector. For instance, the inflaton potential is proportional to phi^{2/3} during inflation in the NMSSM.

2010-01-01

7

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies; Valutazione quantitativa dell`enfisema polmonare mediante Tomografia Computerizzata. Confronto tra il punteggio visivo con alta risoluzione nell`inspirazione, maschera della densita` automatica con Tomografia Computerizzata spirale nell`espirazione ed esami funzionali respiratori  

Energy Technology Data Exchange (ETDEWEB)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of ...

1997-04-01

8

Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies  

International Nuclear Information System (INIS)

CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of ...

1997-01-01

9

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate ...

2006-04-15

10

Thin-Section CT findings of lung small peripheral adenocarcinoma detected by CT physical examination  

Energy Technology Data Exchange (ETDEWEB)

Subjects were 18 cases with adenocarcinoma of 20 mm or less in diameter, which were detected and resected surgically from September, 1993 to August, 1998. On these cases, thin-Section CT (TSCT) images were compared with pathological findings. Patients were 15 men and 3 women, with mean age of 63.4-year-old. An average tumor size was 11.5 mm (5-17 mm). According to pathological classification of Noguchi, type A as in 6 cases, type B in 3, type C in 7 and type F in 2. TSCT was carried by vas voltage =150 kVp, vas current =200 mA, beam width =2 mm, WW =2000 HU, and WL =-700 HU. The ratio of CT attenuation value in cancer by TSCT correlated with the ratio of aeration rate in the pathologic specimen. The cases of 30% or less on the ratio of CT attenuation value were 100% in types A and B, and 71% in type C. These results suggested that it is necessary to devide into two type in group of type C and the ratio of CT attenuation value is important on ...

1999-11-01

11

Bioscavenger for protection from toxicity of organophosphorus compounds.  

Science.gov (United States)

Current antidotal regimens for organophosphorus compound (OP) poisoning consist of a combination of pretreatment with a spontaneously reactivating AChE inhibitor such as pyridostigmine bromide, and postexposure therapy with anticholinergic drugs such as atropine sulfate and oximes such as 2-PAM chloride (Gray, 1984). Although these antidotal regimens are effective in preventing lethality of animals from OP poisoning, they do not prevent postexposure incapacitation, convulsions, performance deficits, or, in many cases, permanent brain damage (Dunn and Sidell, 1989). These problems stimulated the development of enzyme bioscavengers as a pretreatment to sequester highly toxic OPs before they reach their physiological targets. Several studies over the last two decades have demonstrated that exogenously administered human serum butyrylcholinesterase (Hu BChE) can be used successfully as a safe, efficacious, and single prophylactic treatment to counteract the toxicity of ...

2006-01-01

12

Isolation and characterization of an ornithine aminotransferase-related sequence (OATL3) mapping to 10q26  

Energy Technology Data Exchange (ETDEWEB)

The authors used a near full-length human ornithine [delta]-aminotransferase cDNA, huOAT6, as a probe under low stringency hybridization conditions to identify a new autosomal ornithine [delta]-aminotransferase-related sequence (OATL3). Cloning and characterization of this sequence reveal it to be a partial nonprocessed pseudogene corresponding to exon 3 and flanking intronic sequences of the ornithine [delta]-aminotransferase structural gene. Using somatic cell hybrids and fluorescence in situ hybridization, they mapped OATL3 to 10q26, adjacent to the ornithine [delta]-aminotransferase structural gene locus. 13 refs., 3 figs.

1993-08-01

13

Effect of season on contractile and metabolic properties of desert camel muscle (Camelus dromedarius)  

British Library Electronic Table of Contents (United Kingdom)

Thirty fattened one humped desert camels were used to examine the effect of season on contractile and metabolic properties of Longissimus thoracis (LT) muscle. Ten camels were slaughtered according to seasons of the year (winter, summer and autumn). Season significantly influenced muscle chemical composition, ultimate pH (pHu) and color. Activities of metabolic enzymes were higher during autumn season compared to summer and winter for phosphofructokinase (+64% compared to both seasons) and for isocitrate dehydrogenase (+35% and +145% in autumn vs. summer and winter, respectively). Quantification of muscle myosin heavy chain isoforms by SDS-PAGE electrophoresis showed only presence of type I and type IIa MyHC in camel muscle and indicated high proportion in winter for type I and in autumn f...

2012-01-01

14

Role of early phase helical CT images in the evaluation of wall invasion of colorectal cancer. Pathological correlation  

Energy Technology Data Exchange (ETDEWEB)

The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CT images, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, mean: 95.1 HU). The strongly enhanced image areas on CT corresponded to the primary cancer areas on histopathological specimens. A ...

2000-02-01

15

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image ...

2003-12-01

16

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image quality was ...

2003-12-01

17

Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in ...

2003-04-01

18

CT colonography: optimisation, diagnostic performance and patient acceptability of reduced-laxative regimens using barium-based faecal tagging  

Energy Technology Data Exchange (ETDEWEB)

To establish the optimum barium-based reduced-laxative tagging regimen prior to CT colonography (CTC). Ninety-five subjects underwent reduced-laxative (13 g senna/18 g magnesium citrate) CTC prior to same-day colonoscopy and were randomised to one of four tagging regimens using 20 ml 40%w/v barium sulphate: regimen A: four doses, B: three doses, C: three doses plus 220 ml 2.1% barium sulphate, or D: three doses plus 15 ml diatriazoate megluamine. Patient experience was assessed immediately after CTC and 1 week later. Two radiologists graded residual stool (1: none/scattered to 4: >50% circumference) and tagging efficacy for stool (1: untagged to 5: 100% tagged) and fluid (1: untagged, 2: layered, 3: tagged), noting the HU of tagged fluid. Preparation was good (76-94% segments graded 1), although best for regimen D (P = 0.02). Across all regimens, stool tagging quality was high (mean 3.7-4.5) and not significantly different among regimens. The ...

2008-01-15

19

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = ...

2010-02-15

20

Supergravity Higgs Inflation and Shift Symmetry in Electroweak Theory  

CERN Document Server

We present a model of inflation in a supergravity framework in the Einstein frame where the Higgs field of the next to minimal supersymmetric standard model (NMSSM) plays the role of the inflaton. Previous attempts which assumed non-minimal coupling to gravity failed due to a tachyonic instability of the singlet field during inflation. A canonical K\\"{a}hler potential with \\textit{minimal coupling} to gravity can resolve the tachyonic instability but runs into the $\\eta$-problem. We suggest a model which is free of the $\\eta$-problem due to an additional coupling in the K\\"{a}hler potential which is allowed by the Standard Model gauge group. This induces directions in the potential which we call K-flat. For a certain value of the new coupling in the (N)MSSM, the K\\"{a}hler potential is special, because it can be associated with a certain shift symmetry for the Higgs doublets, a generalization of the shift symmetry for singlets in earlier models. We find that K-flat direction has ...

2010-01-01

 
 
 
 
21

Preliminary investigation of /sup 252/Cf-driven neutron noise analysis for subcritical fuel solution systems  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with a solution ...

1981-01-01

22

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months ...

2000-12-01