Energy Technology Data Exchange (ETDEWEB)
The technical development of electric cables in the history of the Berlin electric utilities looks back on more than one century of continuous progress from jute-insulated direct-voltage cables, to 30 kV paper-insulated mass-impregnated cables, 110 kV plastic-insulated cables, 380 kV oil-filled cables, and 380 kV XLPE cables which are increasingly used today. A brief review informs about the major stages of power cable development. (orig.).
1992-05-15
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.
2009-07-01
Life estimation of high-voltage electric cable. Koden prime atsu cable no jumyo yosoku
Energy Technology Data Exchange (ETDEWEB)
An explanation is given of life estimation of CV cable and OF cable which are generally used as high-voltage power cable. CV cable uses XLPE (crosslined polyethylene) and OF cable uses oil-immersed paper as electrical insulators. Relating to CV cable, voltage deterioration due to partial discharge and electric treeing occurs in a high electric field, and by extrapolating the data of up to the actually used electric field in this high electric field, the life is estimate (there is an n-power deterioration law which is V{sup n} = t between breakdown voltage V and electric applied time t). Validity of this extrapolation, however, is a future issue. Further, in the use under the immersion condition, water tree deterioration phenomena influenced by water content and the electric field which are characteristic of CV ...
1991-12-15
Energy Technology Data Exchange (ETDEWEB)
Long duration investigations on XLPE-insulated, medium-voltage cable have been intensively carried out by producers, institutes and users for decades. These tests have concentrated on cable ageing especially under the influence of water. About six years ago, a standard test procedure was developed based on comprehensive know-how. This test procedure is now included in DIN VDE 0276-620. In the following text, experience gained during testing and while performing tests in numerous laboratories is reported, and a summary of the test results is given. (orig.) [Deutsch] Langzeituntersuchungen an VPE-isolierten Mittelspannungskabeln, die sich mit der Alterung der Kabel, besonders unter dem Einfluss von Wasser beschaeftigen, wurden seit Jahrzehnten durch Hersteller, Institute und Anwender intensiv betrieben. Basierend auf diesem sehr umfangreichen Know-how wurde vor rd. sechs Jahren ein standardisiertes Pruefverfahren entwickelt, ...
1997-06-30
Effect of antioxidants on aging of nuclear plant cable insulation
International Nuclear Information System (INIS)
The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants were noted. No antioxidant or antioxidant combination was identified as being ...
XLPE cables move in on underground transmission
Energy Technology Data Exchange (ETDEWEB)
Recent developments in cross-linked polyethylene cables mean they can be used at higher voltages and are starting to replace some oil-filled cables. Their good thermal and electrical properties, easy installation and minimal maintenance have helped their growth. A group at Sumitomo Electric Industries Ltd., Japan is studying the performance of these cables. (author).
1986-02-01
External gas pressure oil filled cable; Gasaussendruck-Oelkabel
Energy Technology Data Exchange (ETDEWEB)
Only two types of 110-kV-cables: Namely XLPE-Cables and External-Gas-Pressure-Cables will be reinstalled in the Federal Republic of Germany. XLPE-Cables have been already developed for higher voltages. An idea how the external-gas-pressure-cable could be made fit for higher voltage levels will be given in this paper. (orig.) [Deutsch] In der Bundesrepublik Deutschland werden in der Zukunft nur noch zwei Kabeltypen der 110-kV-Ebene den Kabelmarkt beherrschen, naemlich: VPE-Kabel und Gasaussendruck-Kabel. Waehrend VPE-Kabel auch fuer hoehere Spannungsebenen bereits entwickelt worden sind, wird im folgenden vorgeschlagen, wie auch das Prinzip der Gasaussendruck-Kabel zu hoeheren Spannungen hin erweitert werden kann. (orig.)
1997-06-02
Checking the condion of 500 kV cable lines by chromatographic analysis of gases dissolved in oil
Energy Technology Data Exchange (ETDEWEB)
A chromatographic technique is described for checking the condition of cable insulation by analyzing cable oil for the gases that are typical of defects in power transformers: carbon dioxide, acetylene, methane and ethylene. This technique was successfully used for predicting breakdown of insulation on KL-2 cable at one of the hydroelectric plants of Kirgizglavenergo power grid 1.5 months in advance. The presence of the above-mentioned gases in cable oil can provide a signal for monitoring the state of cable insulation. Further research is needed in addition to more operational experience to work out criteria for objective evaluation of the state of cable lines.
1980-03-01
Evaluation of 230 kV HPFF pipe-type cable with wrinkled and creased insulating tapes
Energy Technology Data Exchange (ETDEWEB)
Severe collapse wrinkles and circumferential creases were discovered in the cellulose paper insulating tapes of a newly installed IIPFF pipe-type cable during splicing and terminating. An evaluation program was developed to assess the electrical and mechanical integrity of the cable having wrinkled and creased insulating tapes. The test results indicated that the cable would perform satisfactorily in service.
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
A historical review on insulated cables for power transmission, is presented, beginning with impregnated paper insulation, oil filled cables and natural rubber cables. High density and chemically reticulated polyethylene were then used for high voltage and very high voltage cables; the advantages of polyethylene compared to impregnated paper cables are discussed, which led to research programs at EDF on various themes concerning the optimization of polyethylene cables: dielectric properties and reliability, thermomechanical behaviour, thermal ageing of materials, testing methods (acceptance dielectric test and long duration temperature test); utilization of low- and high-density and chemically reticulated polyethylene for 225 kV cables is discussed
1997-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the development of cellulose paper/plastic film/cellulose paper laminate insulated Self-Contained 500 kV Oil-Filled (OF) Cable and its accessories. Dielectric loss of this new cable was confirmed to be about one third that of conventional kraft paper cable. Moreover, by employing the reduced insulation thickness of 25 mm rather than that of 33 mm, as is usual with conventional cables, the new cable could be made very compact, due to the high dielectric strengths of laminated paper. As a result, the shipping reel length of the new cable, which is about 10% lighter in total weight and 10% smaller in overall diameter than conventional cables, could be dramatically increased. The reliability and the stability of the new cable have been demonstrated by the ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The microelectronic cable diagnosis is a substantial tool to determine destruction free the residual strength and the lifetime of laid PE/XLPE medium voltage cables. Fundamentals of the ageing diagnosis and a cost reduced inspection concept are the `Isothermal-Relaxation-Current` Analysis and the Neuro-Fuzzy evaluation software. These new tools are able to determine the ageing status of the investigated cable without any references. The authors also show that the test breakdown during the assessment of the ageing status of criterial systems can be reduced by this approach. The cable diagnosis equipment KDA is also useful for the steering of investment as well as for preventive maintenance. (orig.) [Deutsch] Die zerstoerungsfreie dielektrische Kabeldiagnostik kann heute einen wesentlichen Beitrag zur Bestimmung der Restfestigkeit und der Restlebensdauer eines PE/VPE-isolierten ...
1997-12-15
British Library Electronic Table of Contents (United Kingdom)
The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.
2010-01-01
Fully synthetic taped insulation cables
Energy Technology Data Exchange (ETDEWEB)
A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.
1984-12-11
HVDC cable design logic for digital computers
Energy Technology Data Exchange (ETDEWEB)
The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.
1992-10-01
Development of 275kV oil-filled cable insulated with polypropylene laminated paper (PPLP)
Energy Technology Data Exchange (ETDEWEB)
In 1969, the authors started R and D on a polypropylene laminated paper (PPLP) as a new low-loss insulating paper for oil-filled (OF) cables. Through the material research and the trial manufacture of 275 kV OF cable and four years of long-term field test, PPLP has reached the stage of commercial use. This paper introduces a summary of the history of the development of PPLP, the characteristics of PPLP and cable, the results of long-term field test of 275 kV cable, and other relevant data.
1982-12-01
Energy Technology Data Exchange (ETDEWEB)
An oil-immersion electrically insulated cable of high performance is constructed by wrapping a conductor with an insulating layer formed by winding on the conductor polypropylene film, and impregnating the insulating layer with an insulating oil preferably dodecyl benzene. The polypropylene film has a density in the range of 0.905 to 0.915 g/cm/sup 3/, birefringence in the range of 0.020 to 0.035, ratio of strengths in two axial directions (tensile strength in the longitudinal direction/tensile strength in the lateral direction) in the range of 5 to 15, and thickness in the range of 70 to 300 microns.
1987-08-14
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level ...
2000-05-01
Monitoring oil pressure in h. v. cables
Energy Technology Data Exchange (ETDEWEB)
The paper-insulated low-pressure oil-filled cable invented in 1917 has been used throughout the world as the major cable system for voltages from 33kV to 525kV and experimentally to 1100kV. The proven reliability of the design is amply demonstrated by the cables installed in the early 1930s still currently in service. The inherent design of an oil-filled cable requires that the low viscosity oil is retained within a lead or aluminium sheath. Changes in oil volume due to changes in ambient temperature and load are accommodated by oil reservoirs which maintain the cable oil pressure within design limits. A microprocessor monitoring system that allows early detection and quick location of oil leaks from high voltage oil-filled cables is described.
1985-03-01
Marine cables for high power; Sjoekabel med hoeyere effekt
Energy Technology Data Exchange (ETDEWEB)
A new type of impregnation jelly can be used instead of traditional oil may reduce the formation of cavities in marine high-voltage direct current cables. This provides a foundation for the development of cables with improved insulation and for higher power. This was a conclusion of the Norwegian ''EFFEKT''-project. Using the jelly reduces the size of the cavities substantially and no discharges seem to occur during formation, growth and collapse of cavities. It is also environmentally friendly, since there is no leakage of oil.
2001-07-01
Development of radial-flow type internally oil-cooled oil-filled cable
Energy Technology Data Exchange (ETDEWEB)
A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.
1988-01-01
Polypropylene/paper laminates as high voltage power cable insulation
Energy Technology Data Exchange (ETDEWEB)
A study was carried out to identify optimal laminate/oil combinations for low pressure oil filled and high pressure pipe-type cables, and to establish taping criteria under factory conditions. Laminates from two sources were evaluated in conjunction with Sun XX high viscosity mineral oil and Cosden 015SH polybutene oil for high pressure type cables, and Dussek TC-2288N mineral oil, Shell P2 dedecylbenzene and Chevron DF-100 alkylbenzene for low pressure oil-filled cables. Swelling tests, infrared analysis, dissipation and dielectric measurements, impulse tests and a taping trial were performed. It was found that there is no appreciable difference in performance of both laminates when tested on model cables in a variety of oils. Both types exhibited superior aging characteristics vis-a-vis cellulose paper when tested with a variety of oils and at temperatures up to 105{degree}C. For pipe type ...
1983-08-01
Back-up for high voltage cable pressurizing system
Energy Technology Data Exchange (ETDEWEB)
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
1982-07-19
Oil-filled electric cable with alternate layers of plastic and paper tape
Energy Technology Data Exchange (ETDEWEB)
This patent describes an oil-filled electric cable and a manufacturing method for said cable, in which the solid insulation is formed, at least in part, by separately applied, alternate layers of cellulose paper tape and of film tapes made of plastic. Prior to application of the tapes around the cable conductor, the moisture content of the paper tape is selected and the swelling of the plastic tape by the oil after application is adjusted, if necessary, such as by immersing the plastic tape in the oil prior to application, so that the swelling of the plastic tape by the oil in the formed cable is offset by the shrinkage of the paper tape during drying of the cable. Also, an apparatus for pre-swelling the plastic tape is described. 4 figs.
1988-01-12
Energy Technology Data Exchange (ETDEWEB)
ABB High Voltage Cables AB started the MPS (More Power Submarine cables) project in 1993 with a view to exploring new technology opportunities. The goal is to design and type test a submarine HVDC cable for a capacity of 1200 MW at 600 kV. On the day before ABB announced its success in winning the contract for the world`s largest ever submarine HVDC link project for the gigantic Bakun project in Malaysia, ABB Power Systems described progress to date at a symposium in Karlskrona. The proceedings included a test demonstration on an extruded cable which eventually broke down at a stress of over 935 kV -not in the insulation itself but in the end terminations. The electric field was in excess of 200 kV/mm which is higher than ever before reported. (UK)
1996-07-01
Electrohydrodynamic pumping in cable pipes. Final report
Energy Technology Data Exchange (ETDEWEB)
Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities ...
1983-02-01
Energy Technology Data Exchange (ETDEWEB)
The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient ...
1996-08-01
High temperature liquid level sensor
International Nuclear Information System (INIS)
A length of metal sheathed metal oxide cable is perforated to permit liquid access to the insulation about a pair of conductors spaced close to one another. Changes in resistance across the conductors will be a function of liquid level, since the wetted insulation will have greater electrical conductivity than that of the dry insulation above the liquid elevation.
1983-03-01
Rehabilitation of a gassy low pressure liquid filled 115 kV cable
Energy Technology Data Exchange (ETDEWEB)
The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The ...
1994-12-31
PILC cable technology and accessories
Energy Technology Data Exchange (ETDEWEB)
Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it ...
1996-08-01
Eddy current inspection of superconducting cable during manufacturing
Energy Technology Data Exchange (ETDEWEB)
The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current ...
1992-03-01
Eddy current inspection of superconducting cable during manufacturing
International Nuclear Information System (INIS)
The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures is costly both financially and because of the time needed to recover from them. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers, which drastically reduce the mechanical integrity of the strand and thus of the cable itself. But because of the large volume of cable that will be manufactured, an automated flaw detection system that can inspect the cable and detect these types of defects will be needed. We have recently done an on-line experiment using an Eddy current system and specialized Eddy current probes to inspect ...
1992-03-04
Oil-filled, multi-core cable with at least one conductor differing from others
Energy Technology Data Exchange (ETDEWEB)
This patent discloses an oil-filled, multi-core, electric cable having three cores within a metal sheath suitable for underwater applications. Each core has a conductor surrounded by insulation and has substantially the same outer dimensions as the other cores. One conductor is made of copper and has a central oil duct. The other conductors are made of stranded aluminum wires in side-by-side and contacting relation and the ratio of the cross-sectional area of the metal of the copper conductor to the cross-sectional area of the metal of each aluminum conductor is the reciprocal of the ratio of the electrical conductivities thereof. One object of this invention is that of overcoming the drawbacks existing in the known oil-filled, multi-core cables, i.e. to provide cable which, in case of a rupture of the cable sheath, has fairly small leakages of insulating, fluid ...
1987-02-03
Laboratory development of +- 600 kVdc pipe type cable systems
Energy Technology Data Exchange (ETDEWEB)
In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe ...
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
While underground power transmission lines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that ...
1999-02-10
HVDC submarine power cables systems state of the art and future developments
Energy Technology Data Exchange (ETDEWEB)
The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper describes the dielectric and accelerated aging tests on prototype {plus minus}500 kV dc oil-filled self-contained cables. The extensive test program was required to evaluate the High-Voltage cables for the St. Lawrence river crossing of the {plus minus}500 kV Quebec-New England HVDC power transmission system. The paper relates the main elements of the test program. It describes the required insulation levels, the characteristics of the cables supplied by three different manufacturers, as well as the cables' installation for the type tests and accelerated aging tests. Details of the test program and procedures followed to carry out the tests are given. Findings of the tests are also reported.
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the ...
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the ...
1998-10-13
A Insulating Design of SF{sub 6} GAS Sealing end of Condenser Cone Type Used for 345 kV OF Cable
Energy Technology Data Exchange (ETDEWEB)
In this paper, we describes the research in condenser cone of SF{sub 6} gas sealing end for 345 kV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory and FEM. As a results, we have been designed the condenser cone and the inner insulation part of SF{sub 6} sealing end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone. (author). 4 refs., 3 figs., 3 tabs.
1994-07-01
UK PubMed Central (United Kingdom)
Heavy high viscosity oils, transformer oils, and very light low viscosity oils have been used in a Norwegian company in the impregnation, sheathing, and installation of paper insulated cables. The aim...Full Text Available
1988-09-01
Energy Technology Data Exchange (ETDEWEB)
A detailed examination of the aging processes that may take place in solid-dielectric extruded-type high voltage transmission cables under dry conditions is presented. Particular emphasis is placed on the aging process as affected by the separate and simultaneous action of four main aging factors, namely the electrical, mechanical and thermal stresses, and the physical and chemical environment. A number of pertinent aging models are considered and their validity and applicability to accelerated aging tests on solid-type transmission cables are discussed.
1994-01-01
Increasing pipe-cable section lengths. Final report
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the results of an experimental program which developed a needed reliable data base on modern pipe-type cable construction from which designers can knowledgeably consider maximizing cable pulling lengths with resulting cost savings. The program comprised evaluations of available commercial constructions over the range of conductor sizes (both copper and aluminum) and insulation thicknesses in general utilization. The work focussed on determining the cable's performance under the three mechanical stress modes to which the cable is subjected during installation; (a) tension and elongation, (b) torsion and (c) sidewall (bearing) pressure in bends. Additionally, the program included experimentation to determine the effective coefficient of friction of the various combinations of modern skid wire materials and pipe filling oils used as lubricants with the ...
1983-03-01
Cable-to-air terminations: The cable system's second weakest link
Energy Technology Data Exchange (ETDEWEB)
Transmission terminations available today are very reliable, but they need to be. In the field, they are continually exposed to pollution and extremes of ambient temperature. In many cases, they are in the rifle sights of vandals. In contrast, cable joints - often cited as the weakest links from an electrical viewpoint - are generally protected from physical damage underground and many of the short cable systems being installed in the US today can be built without joints. All cable systems need terminations - mostly to air-insulated equipment. At 69 through 138 kV, there is intense competition among manufacturers to supply terminations for solid-dielectric cable that are low in cost, reliable, and require a minimum of skill to install. Some utilities are looking also for terminations that fit a range of cable sizes; terminations that do not contain liquid that ...
1994-12-01
Resistive cryogenic cable economic-viability evaluation. Final report, Volume I
Energy Technology Data Exchange (ETDEWEB)
This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It ...
1980-03-31
Energy Technology Data Exchange (ETDEWEB)
CIGRE has set up a new working group - Insulated High Voltage Cables - under the auspices of Study Group 21. The working group will examine the various techniques used for the installation of HV and EHV cables and the design parameters to be applied. Twelve installation techniques are known, but only three of these ar used at present. Following an international study carried out by the working group, a clear picture of the state of the art in 1998 has emerged. It has also been possible to identify future trends in the design of buried circuits. (authors)
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground ...
1992-03-01
Repair of failed 138kV pipe type cable line
Energy Technology Data Exchange (ETDEWEB)
On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short ...
1996-11-01
Oil-filled cable surveillance system using newly developed optical fiber gas sensor
Energy Technology Data Exchange (ETDEWEB)
A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.
1996-04-01
Development of flexible joint for 500kV Al-sheathed O. F. cable
Energy Technology Data Exchange (ETDEWEB)
This paper reports on a flexible dimensionaly flush joint for 500kV aluminum-sheathed oil-filled cables capable of being assembled, pulled an installed in a similar manner to cables at site which has been developed. This joint is intended for use at intermediate points on long bridges or tunnels where local assembly and installation of conventional joints would be difficult. In developing the joint various novel and original techniques have been employed, including the flexible flush jointing of segmental conductors, the flexible jointing of paper insulation by a combination of wrapping-back and stepping methods, plus on-site aluminum sheath corrugating and sealing methods.
1992-10-01
White oils for high voltage cables
Energy Technology Data Exchange (ETDEWEB)
S-120 white oils are used to impregnate insulation and fill high voltage wires. Cooling oil flows of specified viscosities can increase the load capacity of wires. White oils are studied for viscosities and dielectric properties. To meet requirements, S-220 type oils of different medium or low viscosities are tested. Capacity can be increased by viscosity adjustment. Tests were also made to select optimum stabilizing additives to keep low-viscosity.
1983-05-01
Laser applications. Final report
Energy Technology Data Exchange (ETDEWEB)
Processes were developed that use lasers as manufacturing tools. These processes were stripping of insulation from cables and wires, machining of quartz, microdrilling and welding of reflective metals, and precision alignment of curved surfaces before machining. A technological basis also was formed which resulted in a process for automatic surface inspection of parts and aided development of machining processes for Kevlar parts.
1980-07-01
Emergency ampacities of direct buried three phase underground cable systems
Energy Technology Data Exchange (ETDEWEB)
A thermal model is formulated for the determination of the emergency transient ampacities of a three phase, horizontally spaced underground cable system. The model is based on a finite difference heat transfer analysis and the principle of superposition which permits the summation of the temperature rise of individual heat sources to eventually provide for the temperature rise of a multiple cable system. The thermal model is transformed into a complex computer program that is capable of calculating the real time cable temperature for any change in conductor current. The program is used to calculate the response of conductor temperatures caused by both ramp and step changes in currents for four conductor sizes between 4/0 and 1500 kcmil. The amount of time to reach conductor temperatures of 100/sup 0/C and 120/sup 0/C from a steady conductor temperature of 75/sup 0/C is calculated for the different conductor sizes and for ...
1983-07-01
White oils for high voltage cables
Energy Technology Data Exchange (ETDEWEB)
''S-220'' white oil is used currently to impregnate and fill high voltage cables for 110-500 kilovolts; it has high electrical characteristics and meets production and use standards. High pressure and cooling problems, however, require filling cables with lower viscosity oils, while insulation needs still demand high viscosity. The authors developed a new white oil similar to S-220 using a neutral oil made in producing sulfonate additives. The process involved vacuum distillation, low-temperature paraffination, sulfation with oleum, neutralizing with ammonium hydroxide and simultaneous extraction of sulfo-salts and contact purification. The lowest content of aromatic hydrocarbons was sought. Dielectric qualities varied with viscosity. Satisfactory thermooxidational capability was found at 50/sup 0/C with an oil of no less than 50 mm/sup 2//sec viscosity. The final white oil had no more ...
1982-10-01
International Nuclear Information System (INIS)
Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...
1992-10-01
International Nuclear Information System (INIS)
Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...
1992-01-01
Weld integrity of the superconducting cable aluminium jackets of W7-X
Energy Technology Data Exchange (ETDEWEB)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...
2009-06-15
Weld integrity of the superconducting cable aluminium jackets of W7-X
International Nuclear Information System (INIS)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...
2009-06-01
Proceedings: Water treeing and aging
Energy Technology Data Exchange (ETDEWEB)
This report presents the record of the workshop Water Treeing and Aging.'' The workshop was held in Phoenix, Arizona on December 9--11, 1990 and was sponsored by the Distribution Program of the Electrical Systems Division of the Electric Power Research Institute (EPRI). Attendance at the workshop was by invitation only. Twenty two attendees from seven countries, from universities, research organizations, electric utilities and polymeric materials suppliers took part in this workshop. The workshop was designed to assess progress in the understanding of water treeing phenomena and polymeric cable insulation aging since the last meeting of a similar forum of experts, which was organized by the Office of Exploratory Research of EPRI in December 1985. The objective of the present workshop was to assess progress and to provide direction for further studies in this field. The discussions covered a wide range of subjects including ...
1991-10-01
Energy Technology Data Exchange (ETDEWEB)
The flow of current inside a conductor leads to its overheating. This conductor is also submitted to other climatic phenomena, such as wind, sun light and ambient temperature. The knowledge of this overheating is important to ensure a functioning temperature compatible with the materials used for the conductor manufacturing and with the dip of overhead power lines above the ground and buildings. On the other hand, according to the Laplace works, the flow of current inside parallel conductors induces electromagnetic forces inside them, proportional to the product of currents in both conductors. In the case of short-circuit between aerial power lines or between flexible cables, electrodynamical stresses (traction and flexion) are applied to insulators and holders and important swinging of the lines can be observed. These stresses can be extremely important and must be considered in the design of overhead lines. These two phenomena are analyzed in ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
The flexible, insulated, single strand cables are electrically connected with a cylindrical polar tip (PN) by means of cylindrical and conical shafts for the polar tips, which enter the faces of the divided, multiwire strand, clamped by tension half couplings. The flat ends of the polar tips being joined are positioned in two concentric mandrel bushings, an internal fixed one and an external, axially movable bushing (PV). The internal bushing is rigidly attached to the end of the left polar tip and equipped with three or four rounded, radial openings, whose diameter is determined by the external diameter of the locking device hinges (ShF) of the connecting couplings. The right polar tip is equipped with an annular channel of trapezoidal section into which the locking device hinges enter. The external movable bushing on the right side has a conical turning and on the left, a cylindrical into which the cylindrical spring which holds the movable ...
1981-06-05
Advanced power cable technology. Volume II. Present and future
Energy Technology Data Exchange (ETDEWEB)
In this book an attempt has been made to describe the most recent information, but at the same time set out the fundamentals of cable technology in some depth. A focus is directed on general features of various kinds of cables. This book is written for cable engineers, and those interested in cable research, the book will also be useful to university students and management personnel interested in electric power engineering. This volume contains chapters on Present Cables and Their Improvement and New Types of Cables. (CS)
1983-01-01
Screening of Flexible Cables by Nonlinear Resistance ...
... Abstract : Two traces in flexible cables used in the Milstar agile beam antenna system failed during acceptance testing. ...
1994-01-10
HVDC submarine cables for the Hokkaido Honshu linkage
Energy Technology Data Exchange (ETDEWEB)
The direct-current submarine cable interconnecting Hokkaido and Honshu (hereafter called HH linkage) is an example of installation of an undersea cable for long-distance power transmission crossing a sea strait. In particular, the feature of this interconnection is that an oil-filled (OF) cable is used for the high-voltage side with crosslinked polyethylene (XPLE) cable adopted for the return to comprise a conductor return system. The details of the facilities, especially the design of the OF submarine cable are described. 3 refs.
1981-04-01
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in ...
2006-11-13
International Nuclear Information System (INIS)
LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges ...
2005-06-15
Oil cable pumping plant. Pumpestasjon
Energy Technology Data Exchange (ETDEWEB)
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
1988-12-27
110-500 kV high-pressure cables
Energy Technology Data Exchange (ETDEWEB)
The use of oil-filled high-pressure electric cables has increased significantly. In recent years, the electric cable industry has developed new designs, manufacturing technology, and has mastered the production of 110 to 220 kV cables without using a temporary lead sheath. The design, fabrication, and performance of high-pressure electric cables for power systems are discussed.
1982-08-01
Investigation of anomalous CXR response of filled cables
Energy Technology Data Exchange (ETDEWEB)
An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.
1982-12-01
Improving performance of e. h. v. cable systems
Energy Technology Data Exchange (ETDEWEB)
Following an earlier article on developments to enhance the reliability of supertension oil filled cables and accessories, changes are described in design and installation of complete cable systems which have similarly improved operating performance.
1983-03-04
Evaluation of a solid hydrophone cable
Energy Technology Data Exchange (ETDEWEB)
In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage ...
1982-07-01
Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields
Energy Technology Data Exchange (ETDEWEB)
The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the FPSO, this problem was complex. ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
1994-05-13
Energy Technology Data Exchange (ETDEWEB)
There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal ...
1994-12-31
Hybrid insulator - the excellent post insulator for HVAC and HVDC power station
Energy Technology Data Exchange (ETDEWEB)
A solid layer artificial pollution test was carried out to study the pollution performance of a new type of hybrid station post insulator used in suspension and tensile high voltage transmission lines. The structure of the separated silicone rubber shed and porcelain core hybrid insulator was shown. The new insulator showed excellent pollution performance under both HVAC and HVDC conditions. It also exhibited excellent aging performance in artificial aging tests. The mechanical strength of the hybrid insulator was also better than normal composite insulators. Another advantage revealed was the fact that separated silicone rubber sheds and porcelain core hybrid post insulators are easier to manufacture than normal porcelain post insulators and other hybrid insulators. 5 refs., 6 tabs., 1 fig.
1997-12-31
Long term accelerated aging tests on distribution cables under wet conditions
Energy Technology Data Exchange (ETDEWEB)
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
A small cable yarding system for accumulations of slash on forested land and overstocked non-productive stands is described.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Application, design, and installation of the cable line in steel pipe with oil under pressure for 500 kV is considered. The cable construction and design specifications are presented. Manpower requirements for the installation of the cable, extending from the hydrogenerators to the outdoor switchgears or to the change point where they are connected to overhead power lines, are discussed and data provided.
1980-08-01
High voltage cable in municipal electricity supply
Energy Technology Data Exchange (ETDEWEB)
The author explains current developments in high voltage cable technology and subsequently describes problems inherent in its application, from the users viewpoint, in municipal electricity supply. The planning of a high voltage cable network and the selection of a specific type of cable are not only dependent on the typical properties of various cables but to a major degree also on the feasible laying technique, the power transmitted, the costs, the stellation treatment of the high voltage network, the acceptance requirement, the inductive influence from telecommunication cable, thermal influences from the environment, eventual safeguards from mechanical and chemical damage to the network, frequency of failure and surveillance and breakdown location. In conclusion, the author portrays potential developments in the fields of high and maximum voltage cable from ...
1980-12-22
Method of fusing segments of armored logging cables
Energy Technology Data Exchange (ETDEWEB)
The method is used for repairing armored logging cables. It consists of preparing armor, subsequent connection of current-conducting strands and wires of the armor, and laying of the armor. Sections of connecting the wires of the armor of the lower and upper layers are scattered over the length of the fused section of the cable. In order to improve the fault strength of the cable, the junctions of connection of the armor wires are scattered among themselves at a distance determined by the Euler formula, and thermal tempering of the wire sections is carried out near these junctions, and then the fused section of the cable is reinforced.
1982-01-01
Analysis on Fault for the Underground Cable Systems at Home
Energy Technology Data Exchange (ETDEWEB)
Many power apparatus and underground cable systems have been constructed since 1970 in korea. Recently, as the needs for underground T and D systems increase rapidly, any fault on the systems causes enormous economic losses in our society. Thus, this paper described. (1) Survey on the amount and the increasing rates of the underground cable systems at home and abroad. (2) Survey on fault data for the underground cables and joints at home and abroad.From the analysis on fault data, we analyzed the cause of fault and classified the typical fault mode for the underground cable systems. (author). 5 refs., 3 figs., 11 tabs.
1999-05-01
Design, manufacturing, installation, protection of 345 kV 750 MVA submarine power cables in New York
Energy Technology Data Exchange (ETDEWEB)
This paper describes the criteria used for the thermal, electrical, mechanical, hydraulical design of the submarine power cables crossing Long Island Sound to feed New York City. The cables are of the self contained fluid filled (SCFF) type. There is also a description of the special measures adopted to face the exceptionally aggressive environment, due to presence of hydrogen sulphide and of stray currents (caused by electric railways and pipes cathodic protection). The most significant example of such measures is a third sacrificial armour. Four single-core SCFF cables (one spare) were manufactured in Arco Felice (near Naples, Italy), for the New York Power Authority. The average length of the cables is 13 km, jontless. The Italian cable ship 'Giulio Verne', managed by Pirelli, was utilized for the transportation and laying. The ship is equipped with a turntable ...
1992-04-01
Analysis of hydrogen vehicles with cryogenic high pressure storage
Energy Technology Data Exchange (ETDEWEB)
Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LIQ) or ambient-temperature compressed hydrogen (CH2). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.
1998-06-19
UK PubMed Central (United Kingdom)
The fabrication and characterization of tungsten nanoelectrodes insulated with cathodic electrophoretic paint is described together with their application within the field of neurophysiology....Full Text Available
2005-09-01
Radiographic experience with power transmission equipment
Energy Technology Data Exchange (ETDEWEB)
This paper describes radiography as one of the most efficient and cost effective methods for inspecting electric cabls. Details of one project in particular, i.e., the inspection of high-pressure, oil-filled, pipe-type cables (HPOF) are given. 2 refs.
1980-01-01
From 33kV to 132kV cables: Norweb rises to the task
Energy Technology Data Exchange (ETDEWEB)
Responsibility for the operation and maintenance of the bulk of the 132 kV cable network in England and Wales was transferred from the CEGB to the area boards in the 1970s. Norweb has successfully dealt with the increase in work using in-house expertise exclusively.
1982-09-17
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)
2006-08-15
HPOF transmission-system economic-evaluation program. Final report
Energy Technology Data Exchange (ETDEWEB)
This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.
1983-01-01
Ampacity calculations for mixed underground cable systems in the same ductbank
Energy Technology Data Exchange (ETDEWEB)
The steady state ampacity is calculated for mixed electric power underground cable circuits in a single trench or ductbank. The methodology presented in this paper can be applied to any practical number of balanced, three phase circuits (each in trefoil, pipe or conduit) of different voltage classes, cable sizes, load currents and cable systems to located anywhere within a single trench or ductbank. The different thermal resistivities of the backfill or ductbank and the surrounding soil are taken into consideration. A practical example for 10 circuits in a trench is provided.
1994-12-31
Upgrading the ampacity of HPFF pipe-type cable circuits
Energy Technology Data Exchange (ETDEWEB)
The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.
1994-12-31
Transient sheath overvoltages in armored power cables
Energy Technology Data Exchange (ETDEWEB)
This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
Nexans has developed a new type of high voltage sea cable with metal barrier for dynamic application, suited for floating installations such as vessels, floating wind turbines or floating platforms. A brief presentation of the cable's design (ml)
2007-07-01
Leak location in fluid filled cables using the PFT method
Energy Technology Data Exchange (ETDEWEB)
A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
Four HVDC (high voltage DC) {+-} 250kV submarine OF (oil-filled) cables are to be installed each capable of 1.4-million kW for one dipole channel and two returns for forwarding to Yura Switchyard a part of the power to be generated by a Tachibanawan coal-fired power plant to open in 2000. The first cable is now being laid. They are to cover a distance of 48km on the sea bottom, and their 190mm diameter is the largest in the world and this decreases the required number of cables for a reduction in the construction cost. The installation is executed by use of a dedicated cable laying ship loaded with cables. The ship is equipped with five thruster screws by adjusting which a cable is fed into the sea and laid on the bottom with high positional accuracy in all directions, and with a 10m-accurate DPS (Dynamic Positioning System) besides GPS (Global Positioning ...
1998-07-01
French power for Jersey goes under water
Energy Technology Data Exchange (ETDEWEB)
A proposed project by which the island of Jersy could buy electric power from France is discussed. The interconnector will be capable of transmitting up to 50MW. Included in the project will be 27 km of submarine cable and 23 km of underground cable. An oil-filled cable containing 120 mm diameter copper conductors and weighing 47 kg/m is used. Details of the installation and oil system are given.
1983-01-21
Evaluation of radiation resistance of cable connector material
Energy Technology Data Exchange (ETDEWEB)
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
Equations are compiled for thermal balance in which for simplification, no consideration is made for heat conductivity along the axis of the cable and dependence of losses, heat capacitance and heat conductivity on temperature. Equations are modeled on a transistor analog calculator 42 TA. The solution to the task on the computer produced values of maximum temperature on the cable and coordinates of the point of maximum overheating. Using the analog model, one can study other parameters of the thermal mode.
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.
1985-04-01
Partial discharge in liquid nitrogen
Results are presented of experiments on partial discharge in liquid nitrogen, including insulation breakdown characteristics of liquid nitrogen, partial discharge characteristics of composite insulation systems, lifetime of polymer films, impulse breakdown of polymer films in liquid nitrogen, etc. The partial discharge characteristics of liquid nitrogen are examined with increasing liquid-nitrogen pressure. It is concluded that a composite insulation structure of polymer film and liquid nitrogen can be used as effective electrical insulators at cryogenic temperatures.
1976-01-01
DC CHARACTERIZATION OF HIGH GRADIENT MULTILAYER INSULATORS
Energy Technology Data Exchange (ETDEWEB)
We have developed a novel insulator concept that involves the use of alternating layers of conductors and insulators with periods less than 1 mm. We have demonstrated that these structures perform 2 to 5 times better than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present new testing results showing exceptional behavior at DC, with gradients in excess of 110kV/cm in vacuum.
2005-05-26
Energy Technology Data Exchange (ETDEWEB)
After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.
1992-10-01
Multilayer ultra high gradient insulator technology
Energy Technology Data Exchange (ETDEWEB)
We are investigating a novel insulator concept which involves the use of alternating layers of conductors and insulators with periods less than 1 mm. These structures perform many times better (about 1.5 to 4 times higher breakdown electric field) than conventional insulators in long pulse, short pulse, and alternating polarity applications. We present our ongoing studies investigating the degradation of the breakdown electric field resulting from surface roughness, the effect of gas pressure, and the performance of the insulator structure under bi-polar stress. Further, we present our initial modeling studies.
1998-03-27
Energy Technology Data Exchange (ETDEWEB)
An insulated letter drop plate comprises a back plate having an opening for the mail having two hinges at its upper part to attach a cover to; a frame for retaining a first insulation around its perimeter and around the opening; and suitable insulation. This back plate is also provided with an upper curved extension to cover and conceal said hinges. A cover is provided with two complementary hinges to be articulated with the first hinges on the back plate, and with a frame around the perimeter for the retention of a second insulation. A wire joins the first and second hinges, and a coil spring on the wire keeps the cover normally closed.
1988-09-06
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents the test results of a research program to investigate the performance of polymeric insulators for 15-kV dead-end applications on distribution systems. The test program involved both new insulators from five different manufacturers and naturally-aged insulators removed from service on the distribution system of Pennsylvania Power and Light. The test series to evaluate the new insulators included: preconditioning treatments, salt fog and tracking wheel accelerated aging tests, electrical tests, and material and physical tests. The tests for the naturally-aged insulators were mainly limited to the electrical tests and the material and physical tests.
1989-04-01
Electrical drilling string separator
Energy Technology Data Exchange (ETDEWEB)
The separator can be used for electrical separation of the drilling string used as the channel of communication with transmission of face information. It contains upper and lower metal conductors electrically insulated from each other by an insulator made of layered polymer composite material. In order to improve reliability of the connection of the conductors to the insulator and reduce the metal consumption on the ends of the conductors that come into contact with the insulator there are graduated niches with radial projections. The latter form jointly with the layers of the insulator a crown-radial-multiple stage undetachable connection. The niches decreases from the outer diameter of the conductors to the inner. The insulator has additional layers made of high-module fibers of carbon or boron which cover the radial projections in stages.
1983-01-01
Aerogels: the leading edge in thermal insulation
Energy Technology Data Exchange (ETDEWEB)
Banning CFCs in foamed insulations has led to an intensive search for alternatives which do not incur the penalty of increased thickness. The most promising of these are silica aerogels, which have proven to be the leading material, when it comes to thermal insulation and environmental protection. Refrigerators insulated with aerogels have been tested and compared to conventionally insulated ones. Results showed a substantial contribution to the energy performance. Boiler manufacturers using aerogel have been able to reduce energy consumption of water heaters by 20%. Float glass elements evacuated and filled with aerogel as well as aerogel insulated polyester lightwalls and bubble skylights yield excellent U-values and significantly reduced energy losses in buildings. (author)
1995-01-01
Unique approach to an old problem: New technology helps BC Hydro locate heat resistance
Energy Technology Data Exchange (ETDEWEB)
BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the ...
1997-06-01
Calculation of the transmission capacity of long-distance EHV single-core submarine cable systems
Energy Technology Data Exchange (ETDEWEB)
A general calculation method for the analysis of transmission capability of a long-distance single-core ac submarine cable system is presented. The method is based on modal transformation of voltages and currents in multiconductor cable systems. Using this method, numerical calculations on 500 kV submarine cable systems have been performed with particular reference to the effect of the distance between bonds connecting metallic sheath, outer conductor and armor on the transmission capacity of the system. It was clarified that the transmission capacity of the system increased with decreasing bond intervals. Examination of the current distributions between various conductors along the length showed that this increase of transmission capacity was mainly due to the dispersion of the charging current into the metallic sheath, outer conductor and armoring at the bonding points. Analytical results for the transmission capacities ...
1981-11-01
Application of the CFAST zone model to the Fire PSA
Energy Technology Data Exchange (ETDEWEB)
The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the cable integrity. According to the analysis results, the integrity of the ...
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)
1980-01-01
The homogeneity of the magnetic field in the LHC dipoles strongly depends on the correct position of the superconducting cables: this is related to the quality of the dipole components, such as the dimension of the coil spacers (copper wedges), of the cable and of the collars. The performance in operational conditions is also affected by the magnetization of the cables. In this work, we analyse the measurements of these quantities during the production of the 1276 LHC dipoles, their trends, and the relation to the measured magnetic field. A novel mtehod to locate electrical shorts based on the analysis of magnetic measurements is also presented, and applications to 15 dipoles reascued during the production is given.
2006-01-01
Axiomatic Design Approach for a Reactor Head Structure Assembly
Energy Technology Data Exchange (ETDEWEB)
Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.
2006-07-01
UK PubMed Central (United Kingdom)
BackgroundChromatin insulators or boundary elements are a class of functional elements in the eukaryotic genome. They regulate gene transcription by interfering with promoter-enhancer...Full Text Available
Method of insulating bed water in an oil well
Energy Technology Data Exchange (ETDEWEB)
A method is proposed for operating bed waters in an oil well by injecting silanes into the near-face zone. It is distinguished by the fact that in order to improve the effectiveness of insulation, the silanes used are silanes of general formula Si /SUB n/ H /SUB 2n-n/ .
1982-01-01
Health effects of urea formaldehyde foam insulation: evidence of causation.
UK PubMed Central (United Kingdom)
Studies of health effects of urea formaldehyde foam insulation (UFFI) were critically reviewed by means of accepted rules for evidence of causation. Three categories of health effects were examined:...Full Text Available
1986-04-01
Earlier studies had concluded that the preferred direction of the rocket nozzle should ..... Center had to redesign the sensor canisters, brackets and cable supports. ... depending on inspection of the quality of the incoming pictures in real-time. ...
Test of use of MN-4 oil in 110 to 220 kV cable lines
Energy Technology Data Exchange (ETDEWEB)
Beginning in 1972 low-pressure cables filled with MN-4 oil produced by the Yaroslav Petroleum Processing Plant arrived at the Leningrad Cable Network of the Leningrad Rayon Power Administration. Lines formed with these cables have been successfully used. The parameters of the oil in them have not changed with respect to the values present when the lines were placed in operation. However, from here on filling in of the 110 to 220 kV input lines of low and high pressure will be accomplished with MN-4 oil produced by the Gorkiy Petroleum Processing Plant. Because petroleum from various fields and the properties of the oil produced from it are unlike, samples were taken from some elements of the lines filled in with MN-4 oil. The results of the tests are described.
1980-09-01
Large eddy simulation based fire modeling applications for Indian nuclear power plant
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. Keeping this in mind the deterministic fire hazard analysis was carried out for the Madras Atomic Power ...
2005-07-01
Application of the CFAST zone model to the Fire PSA
British Library Electronic Table of Contents (United Kingdom)
The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the c...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.
1984-11-01
Self-magnetically insulated, high-voltage transmission lines are used in inertial confinement fusion particle accelerators in order to transmit power from the vacuum insulator to the diode. This paper describes a time-dependent 2-D code (MITL) for calculating (for planar or triplate geometries) the motion of test electrons through the tapered input or output convolutes of such lines. MITL results show that the electron canonical momentum in the direction of the flow changes as the electron passes through the convoluted geometry; it is suggested that these electrons lead to losses observed in long self-magnetically insulated lines.
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.
1987-01-01
Vacuum container for use in a thermonuclear device
International Nuclear Information System (INIS)
Purpose: To enable the use of a vacuum container under a relatively high temperature or a high level radioactive dose. Constitution: Vacuum sealing materials for use in a vacuum container are made of resins such as polyimide and polyamide. The sealing materials are joined to the both surfaces of a plate-like insulator by means of adhesives or sealants, or the sealing materials are joined between two plate-like insulators by means of adhesives or sealants. They are situated within grooves of both of flanges, which are clamped tightly by insulation bolt and nut. Since the vacuum sealing materials are joined to the insulator by means of the adhesives or sealants, the reliability of the vacuum sealing can be improved without impairing the electrical insulation. The resin of the vacuum sealing material can be used for the radiation dose up to 10"8 rad, temperature up to 250"0C or more. ...
1982-04-30
Economic thickness for industrial insulation
Energy Technology Data Exchange (ETDEWEB)
This manual is presented in 8 chapters plus appendices. Chapters 1 and 2 are included as background information. The economic insulation thickness is found using the following chapters: Chapter 3, cost of energy (heat and refrigeration); Chapter 4, cost of insulation, and Chapter 5, economic thickness determination. Each of these chapters contains a worksheet, which provides a step-by-step procedure for solving the problem. Nomographs are included in each section for simplifying the required calculations. For subambient temperature systems, the economic insulation thickness calculated with Chapters 3 to 5 should be compared to the thickness required to prevent condensation (sweating), as calculated with Chapter 6. Chapter 7 presents the procedure for calculating economic insulation for retrofit situations. Sample problems are included in Chapter 8.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.
1994-07-11
New advances in mitigating environmental impact of pipe-type cables
Energy Technology Data Exchange (ETDEWEB)
Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.
1999-04-01
Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields
British Library Electronic Table of Contents (United Kingdom)
The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.
2001-07-01
Calculation of current-carrying capacity of forced cooled high-voltage cable lines
Energy Technology Data Exchange (ETDEWEB)
The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current ...
1982-01-01
A liquid barrier filter for use in fluorescence microscopy of strongly autofluorescent plant tissues is described. The filter consists of a methanol solution of cupric chloride and ferric chloride and isolates fluorescein fluorescence from the strong red autofluorescence of photosynthetic plant tissues. Subcortical actin cables in the giant alga Chara are being visualized through use of this filter together with heavy meromyosin labeling. PMID:90068
1979-05-01
Energy Technology Data Exchange (ETDEWEB)
Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.
1980-07-01
Evaluation of advanced technologies for power transformers. Final report
Energy Technology Data Exchange (ETDEWEB)
The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular ...
1981-01-01
Using fiber optic sensors to protect intake, outflow, and other environmentally exposed openings
Energy Technology Data Exchange (ETDEWEB)
This paper reports on the protection of opening that are exposed to the environment in nuclear facilities which presents an almost overwhelming engineering challenge. Intakes and outflows must permit the passage of large volumes of air or water without impeding their flow, and they are often exposed to corrosive salt and chemicals. An intrusion detection sensor that is intended to protect these openings must be capable of operating reliably under environmentally harsh conditions, and at the same time either provide a physical delay barrier or attach to an existing barrier. A new fiber optic sensor technology has now been developed specifically for protecting environmentally exposed openings. This sensor uses a fiber optic cable embedded in a neoprene rubber frame which is reinforced with Kevlar threads or braided steel cable. The sensor is configured in a mesh pattern with openings sufficiently large to permit air or water to flow unimpeded, ...
1991-01-01
Safety gas management system utilizing telephone cable
Energy Technology Data Exchange (ETDEWEB)
This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is necessary to prepare ...
1988-02-10
Energy Technology Data Exchange (ETDEWEB)
Flow Tex and ABB Energiekabel GmbH have developed a technique which allows the recovery of cables without requiring any trenching works. The new technique was successfully used for the first time for a pilot project in 1995. The authors report on two recent recovery projects (1998) in which an optimised technology was used for recovering a total of 1 500 m system length of 110 kV low-pressure oil-filled cables in Stuttgart and Munich on very different conditions. The authors describe the operational experiences with the cable connections and highlight the background stipulating the removal of the cables. (orig.) [Deutsch] Ein Verfahren zur grabungsfreien Bergung von Kabeln, gemeinsam entwickelt von FlowTex und ABB Energiekabel, wurde erstmals in einem Pilotprojekt 1995 mit Erfolg eingesetzt. Die Verfasser berichten ueber zwei Bergungsprojekte, bei denen 1998 mit der optimierten Technik in Stuttgart und ...
1999-03-22
Energy Technology Data Exchange (ETDEWEB)
Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for pipe-type cables with concentric stranded copper conductors ...
1985-04-01
500 kV oil-filled cable installed on bridges
Energy Technology Data Exchange (ETDEWEB)
The 220 kV Ch{bar u}si Trunk Line, now transmitting a maximum of 300 MW of electricity between the Ch{bar u}goku area of Honsh{bar u} and Shikoku island, is expected to be inadequate in the 1990's due to the rise in electrical demand. Therefore, to strengthen this interconnection, a new 500 kV transmission line was proposed. The most significant feature of this transmission line is the installation of 500 kV cables along the bridges (the Seto Ohashi Bridge) which span the Inland Sea (Seto). This is the first 500 kV long-distance transmission cable line. It is also the first large-scale cable line in the world installed along various types of bridges (ten bridges; route length of the bridge portion approximately 8 km). This paper gives an outline of the Honsh{bar u}---Shikoku interconnecting transmission line and also presents some technical features concerning 500 kV cables.
1990-04-01
Analysis of cost-effective pipe insulation requirements
Energy Technology Data Exchange (ETDEWEB)
The proposed ASHRAE/IES Standard 90.1-1989R contains updated requirements for pipe insulation thicknesses developed on the basis of technical and economic principles. These requirements were determined based on computer simulations of the annual energy loss through the insulation, first cost assumptions for the insulation, and economic assumptions of discount rate and energy escalation rate. In later work, the same tools were used to analyze the sensitivity of the cost-effective insulation level for piping insulation to variations in operating hours, ambient temperature, fluid temperature, and economic assumptions. These analyses were carried out using cost data for pipe insulation averaged across several sources. The results of the sensitivity study showed that system operating hours is a critical parameter in determining the cost-effective pipe ...
1997-09-01
Energy Technology Data Exchange (ETDEWEB)
This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend ...
1998-09-05
Electric field measurement on time domain generated by corona on insulators on distribution systems
Energy Technology Data Exchange (ETDEWEB)
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new ...
1996-12-31
Economic thickness for industrial insulation
Energy Technology Data Exchange (ETDEWEB)
The conservation of energy through the use of the optimum economic thickness of insulation has clear benefits for industry in the U.S. Potential energy savings have been estimated to be the equivalent of 250 million of barrels of oil per year over the next decade. As is the case with any capital expenditure, the dollars spent for insulation must be expected to provide the plant owner with a certain return on his investment. This manual provides data and guidelines for estimating dollar costs and insulation life which enable the user to specify the least-cost insulation thickness based on minimum life cycle cost and required percentage return on investment. A large degree of design flexibility is provided for, so that specific economic and design criteria may be taken into account. A number of useful working aids are provided, including sample problems, forms and worksheets, and nomographs which may be ...
1983-01-01
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
Energy Technology Data Exchange (ETDEWEB)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on ...
1992-03-01
Breakdowns of high-voltage transmission lines due to sea-salt deposits on insulators
International Nuclear Information System (INIS)
Until 1990, in Tuscany, salt pollution of anti-salt insulators installed on high-tension transmission lines had led to rare breakdowns. On the contrary, in the last months of 1990, in most of Tuscany, following a strong libeccio wind coming from the Tyrrhenian Sea, and due to a long period of drought, salt deposits accumulated on the insulators of the high-voltage transmission lines (380 kV, 220 kV and 132 kV). This phenomenon not only took place in the coastal areas near Livorno, Pisa and Grosseto, but also in areas far away from the sea such as Florence, Prato, Arezzo and Siena. Following this, several high-tension lines, and whole sections of 380 kV electric stations went out of order, damaging the stations' equipment, insulators on the lines, and in particular porcelain insulators. The maintenance operations that were immediately undertaken consisted in washing operations, first focussed on ...
1992-01-01
Weld integrity of the superconducting cable aluminium jackets of W7-X
British Library Electronic Table of Contents (United Kingdom)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...
1986-04-01
Evaluation of improvements in the installation of rural underground transmission lines: Final report
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.
1987-10-01
Energy Technology Data Exchange (ETDEWEB)
Environmental compatibility is nowadays a very important part in the case of planing, construction, operation and maintainance of cable systems. A lot of laws and orders have to be observed. Some new aspects concerning the removal of oil filled cables and the consideration of electromagnetic fields even for cabels will be presented. (orig.) [Deutsch] Der Umweltschutz ist heute unverzichtbarer Bestandteil der Planung, Bau, Betrieb und Instandhaltung von Kabelanlagen. Zahlreiche Gesetze und Verordnungen sind hierbei zu beachten. Der Verfasser stellt einige Neuerungen im Zusammenhang mit dem Ausbau und Oelkabeln vor und erlaeutert die auch bei Kabeln zu beruecksichtigenden elektromagnetischen Felder. (orig.)
1997-09-22
Energy Technology Data Exchange (ETDEWEB)
This article discusses the use of five-core cables to provide utility customers with the best possible prerequisites for trouble-free operation of electrical installations and equipment. The TN-S system in buildings and the new TN-S-five-core house-connection cable for connections between the mains distribution point and buildings is introduced. The long-term target of providing TN-S-systems in power distribution even as far as the local transformer is also discussed. The advantages of the system are discussed and various configurations for different types of supply are described.
2005-07-01
Results from field experiments on AC polluted insulators in Mexico
Energy Technology Data Exchange (ETDEWEB)
As contamination flashover is in Mexico the second cause of transmission line faults, the Mexican Electrical Research Institute carried out a project to determine pollution patterns for the Republic of Mexico to be used for the design of external insulation. Results from the project are presented: the modelling, based on the field data of 23 experimental sites, of long term variations of pollution patterns as a function of environmental variables, insulator shape and position, as well as other important field results. 32 refs, 2 figs, 4 tabs
1995-12-01
Brittle fracture problem in composite insulators
Energy Technology Data Exchange (ETDEWEB)
The report traces the documented incidences of brittle fracture in composite suspension insulators for use on high voltage transmission lines, and presents the subsequent investigations. It describes the part played by electrical activity, stress corrosion and humidity, and compares similar failures that have taken place in electric traction insulators. It then goes on to review related work on the humidity effects, stress corrosion, fatigue and partial discharges in glass fiber reinforced plastics in general. The final section summarizes the present understanding of the problem and the various measures taken by different manufactures to avoid it in the future. The need for acceptance criteria in this respect is outlined.
1984-04-01
The National Shipbuilding Research Program Task S-20: A ...
... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...
1979-05-01
Multifunctional aerogel thermal protection systems for hypersonic ...
Sep 18, 2007 ... Lightweight structural aerogels would find applications as a component of composite sandwich panels that are both lightweight and insulating ...
Focused ion beam insulator deposition
Energy Technology Data Exchange (ETDEWEB)
Focused Ion Beam (FIB) repairs and modifications to integrated circuits have been somewhat limited in the past due to the physical limitations imposed by the nodes of interest being buried under metal layers, the need for multiple layers of FIB generated interconnects, and the like. With the advent of FIB deposited INSULATOR materials, integrated circuit modifications can now be much more complex. The two primary goals of this project were (1) to determine the appropriateness of FIB insulator deposition for aiding FIB connections to metal nodes buried under power busses, and (2) development of a technique to do this. The work presented in this paper includes the development and characterization phases of adding INSULATION DEPOSITION to a FEI 611 FIB system, the problems encountered, their work around, and the aforementioned application of this technology.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
The paper reports the results of the studies performed at the Electric Research Center of ENEL (Italian National Electricity Board) in the field of compacting high voltage transmission lines, from the point of view of dielectric and corona noise constraints. The results of switching impulse withstand voltage tests, performed on typical compact line insulation configurations, are given and optimization criteria of such insulation configurations in relation to switching impulse are outlined. The constraints regarding surface withstand voltage in polluted conditions of the above insulations are analyzed and the possibility of reducing their dimensions by using unconventional insulation materials is considered. Finally, evaluations of corona noise in the case of optimization of the line encumbrance from the point of view of dielectric constraints are given.
1993-05-01
Averting problems caused by solutions
International Nuclear Information System (INIS)
A brief overview is given of a report on Emergency Core Cooling Systems (ECCS) Recirculation Reliability Knowledge Base compiled by the International Working Group on ECCS Reliability for the OECD/NEA/CSNI. Four safety issues are identified which arise in the context of loss of coolant accidents (LOCAs) and are connected with materials and/or processes that interfere with the ECCS safety function in ways other than just strainer head loss generation. They are: the generation of missiles during a LOCA from encapsulated insulation materials used to reduce insulation debris production; clogging of BWR pressure suppression containment vent pipes by insulation jackets or metallic insulation foil pieces; strainer or sump debris ingestion and the effects of ingested debris on ECCS equipment and core cooling; miscellaneous items such as material aging and self-cleaning strainer concepts. The emphasis is mainly ...
Energy Technology Data Exchange (ETDEWEB)
The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.
1982-07-01
Underground cable: Best for cogeneration links
Energy Technology Data Exchange (ETDEWEB)
This article addresses the connection of cogeneration plants to the utility system. The article provides examples for use in illustrating the problems that must be overcome and the solution chosen. These illustrations include high voltage utility connection, multiple connections to the utility at one location, and dealing with losses and obstructions.
1989-05-01
How to charge electric-powered automobiles; Volle Ladung, aber wie?
Energy Technology Data Exchange (ETDEWEB)
Electric cars can be recharged via charging stations, battery exchange, or induction cable lanes in asphalted roads. The users' wishes remain unexplored, so a number of technologies are competing in this sector.
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
The report summarizes studies of ground, cable, and aerial logging systems in the Northern Rockies over a 15-year period. It provides nomographs and tables for calculating productivity and a system for comparing energy requirements.
1982-09-01
The recent online publication of classified defense documents and diplomatic cables by the organization WikiLeaks and subsequent reporting by the New York Times and other news media have focused attention on whether such publication violates U.S. criminal...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The stand is designed to test supports of development workings. To expand the test range for various types of supports, the cross pieces have fixing devices in the form of winches interacting by cables through blocks fastened to the stand body with the support hinges.
1980-07-30
Submarine 525 kV power transmission line for Vancouver island
Energy Technology Data Exchange (ETDEWEB)
The studies undertaken by the B.C. Hydro company at the Canada showed that the existing system of hydroelectric power plants and transport cables will not be able to satisfy the increasing energy demand on the Vancouver island after 1985, and that the best solution will be the installation of a 525 kV transfer system from the continent. THe STK participated to the development and the immersion of this new system, the first in the world comprising submarine 525 kV transport parts. This paper presents the planning, the development, the submerging and the installation of two sections of submarine cable.
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
The major distributor and retailer of electrical power to Auckland, New Zealand, is Mercury Energy Limited. Following the sequential failure of the four 110kV underground cables, two gas-filled and two oil-filled, which supply the central business district, power was interrupted for 29 days from the 20th February 1998. A government inquiry was instituted, to examine what happened, why, and what lessons could be drawn for the future. Inadequacies in Mercury Energy`s cable maintenance and operating procedures were identified. The findings of the inquiry and its recommendations are reported. (UK)
1998-08-01
Fiber optic quality assurance at the Nevada Test Site
Energy Technology Data Exchange (ETDEWEB)
A large number of fiber optic cables were used in support of a neutron imaging experiment at the Nevada Test Site. This paper describes the quality control testing of fiber components used on this experiment. The principal reason for quality control testing was to ensure reliable, high transmission fibers; a secondary reason was to gain data on a large sample of fiber cables in the field. Also described is the instrumentation developed for carrying out these field measurements. The design of the quality control instrumentation was a compromise between accuracy and simplicity of use.
1981-01-01
Computer modeling of electrical performance of detonators
Energy Technology Data Exchange (ETDEWEB)
An empirical model of detonator electrical performance which describes the resistance of the exploding bridgewire (EBW) or exploding foil initiator (EFI or slapper) as a function of energy, deposition will be described. This model features many parameters that can be adjusted to obtain a close fit to experimental data. This has been demonstrated using recent experimental data taken with the cable discharge system located at Sandia National Laboratories. This paper will be a continuation of the paper entitled ``Cable Discharge System for Fundamental Detonator Studies`` presented at the 2nd NASA/DOD/DOE Pyrotechnic Workshop.
1995-05-01
Energy Technology Data Exchange (ETDEWEB)
A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.
1980-01-01
The electrical measurement of AC losses in a three-phase tri-axial superconducting cable
International Nuclear Information System (INIS)
In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are essentially single-phase measurements with only one transport current ...
2010-09-01
Fire preventive materials for nuclear power plants
International Nuclear Information System (INIS)
With the fire accident in Browns Ferry nuclear power plant as a turning point, the regulation against fire has been strengthened more strictly as seen in the regulatory guide of the United States Nuclear Regulatory Commission. Fire of cables is caused by either the ignition of a cable itself or spread of fire to cables. The aspect of fire is divided into the local ignition and combution and the fire extension and prepagation because of the line-shaped configuration of cables. This report describes the prevention of the spread of fire. As the materials for the prevention of fire spread, fire spread-preventing paint ''Dannekka'', sealant ''Danseal P and L'', and fire prevention tape ''FD tape'' are reported, and the testing method and the results are described in detail. ''Dannekka'' is classified into the solvent dispersion type and the water dispersion type. It may be coated with brush or by spraying. ...
Negative ion formation in magnetically insulated transmission lines
Energy Technology Data Exchange (ETDEWEB)
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
1982-05-01
International Nuclear Information System (INIS)
We study the possibility of utilizing the superfluid to Mott-insulator quantum phase transition in an array of quantum well exciton-polariton traps to generate indistinguishable single photons in a massive parallel fashion. By means of analytical and numerical methods, the device operations and system properties are examined using realistic experimental parameters. Such a deterministic, massive parallel generation may find new applications in photonic quantum information processing.
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase in insulating layer ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Properties of highly correlated electrons, such as heavy fermion compounds, metal-insulator transitions, one-dimensional conductors and systems of restricted dimensionality are studied theoretically. The main focus is on Kondo insulators and impurity bands due to Kondo holes, the low-temperature magnetoresistivity of heavy fermion alloys, the n-channel Kondo problem, mesoscopic systems and one-dimensional conductors.
1998-10-12
Fault prediction on high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
The prediction of faults on high voltage transmission lines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmission line radio noise, hence faults can be predicted.
1982-12-01
Analysis of a 1200 kV circuit breaker for a gas insulated substation. Final report
Energy Technology Data Exchange (ETDEWEB)
This report describes the work carried out to analyze and design a circuit for use in 1200 kV gas insulated substations. The first part of the project was devoted to a thorough analysis of the requirements for the circuit breaker from the standpoint of the electrical system in which it would operate. A conceptual design was selected and all of the components of the circuit breaker were designed, modeled and verified. Finally a plan was prepared for the construction of a complete circuit breaker.
1985-01-01
A magnetically insulated negative ion source for neutral beam heating
Energy Technology Data Exchange (ETDEWEB)
A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.
1983-08-01
Energy Technology Data Exchange (ETDEWEB)
As a part of the WE-NET project, the tanker for liquid hydrogen transport was studied. In fiscal 1996, some experiments and numerical analyses were proposed which are necessary to solve technological issues extracted in fiscal 1995 for heat insulation structure. The issue was roughly classified into vacuum and non-vacuum insulation, and their basic functions and required performance were arranged. Boil-off rate of 0.2-0.4%/d was targeted. The insulation system which applies polyurethane form (PUF) to tank surfaces and injects atmospheric N2 gas into the surrounding hold space, could achieve the targeted insulation performance by PUF of 1m in thickness. The system of vacuum panel insulation and atmospheric N2 gas injection into a hold space required the panel of 500mm in thickness because of the large effect of metallic outer panel material. The system of vacuum hold and PUF panels ...
1997-03-01
Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report
Energy Technology Data Exchange (ETDEWEB)
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between cable pipes ...
1984-07-01
Thermal control of electric vehicle batteries
Energy Technology Data Exchange (ETDEWEB)
The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature batteries.
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports on a series of laboratory and controlled test site measurements of the thermal conductivity of polyisocyanurate foam laminated boardstock roof insulations produced with several different blowing agents; CFC-11, HCFC-123, HCFC-14lb, and two blends of the HCFCs. The behavior of the experimental foams with HCFCs is compared to that of conventional polyisocyanurate foam blown with CFC-11. Thermal drift observed from two years of field exposure is compared to laboratory accelerated aging tests and the laboratory and field measurement techniques are described. This work is part of a Joint Industry/Government Project established in the United States to evaluate the technical viability of HCFC alternative blowing agents for polyisocyanurate foam roof insulations.
1992-01-01
Testing and design of radon resisting membranes based on the experience from the Czech Republic
International Nuclear Information System (INIS)
Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10"-"1"5 m"2/s to 10"-"8 m"2/s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by ...
STATUS OF THE DIELECTRIC WALL ACCELERATOR
Energy Technology Data Exchange (ETDEWEB)
The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.
2009-04-22
Energy Technology Data Exchange (ETDEWEB)
A number of buildings dating from the 1950s and 1960s were retrofitted with thermal insulation in order to cut energy consumption. This took place within the building competition 'Therma' nitrated by the Federal Ministry of Regional Planning, Building and Town Planning in 1974. Result at that time were so encouraging that now, 15 years later the results were checked again with special attention to the long-term performance of the thermal insulation measures. Laboratory tests prove that the building materials are still in good condition and that humidity has not increased with age. Cracks in the surface plaster of the compound insulation systems occurred at different frequencies and intensities and usually caused by thermal tensions. (BWI).
1992-04-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
The danger potential for 110 kV cables, which are installed on racks and in tunnels, caused by catching fire because of arcing short circuits and mechanical overstressing by peak shortcircuit current, has been experimental analysed under Bewag network conditions. As a result, recommendations for an improved installation of 110 kV cables are given. (orig.) [Deutsch] Fuer offen gelegte 110-kV-Kabel in Raeumen, auf Fussboeden und in Schaechten wurde das von Kurzschluessen auf den Kabeln ausgehende Gefaehrdungspotential fuer die Entstehung von Kabelbraenden durch Fehlerlichtboegen und fuer eine mechanische Ueberbeanspruchung von Kabeln durch Stosskurzschlussstroeme unter Beruecksichtigung der Netzverhaeltnisse der Bewag experimentell untersucht. Im Ergebnis geben die Verfasser Empfehlungen fuer die sichere Anordnung offen gelegter 110-kV-Kabel. (orig.)
1998-03-23
Ramp-rate sensitivity of SSC dipole magnet prototypes
Energy Technology Data Exchange (ETDEWEB)
One of the major achievements of the magnet R&D program for the Superconducting Super Collider (SSC) is the fabrication and test of a series of 20 5-cm aperture, 15-m long dipole magnet prototypes. The ramp rate sensitivity of these magnets appears to fall in at least two categories that can be correlated to the manufacturer and production batch of the strands used for the inner-coil cables. The first category, referred to as type-A, is characterized by a strong quench current degradation at high ramp rates, usually accompanied by large distortions of the multipole fields and large energy losses. The second category, referred to as type-B, is characterized by a sudden drop of quench current at low ramp rates, followed by a much milder degradation at larger rates. The multipole fields of the type-B magnets show little ramp-rate sensitivity, and the energy losses are smaller than for the type-A magnets. The behavior of the Type-A magnets can be explained in terms ...
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
A dipole magnet based on the common coil design, using prereacted Nb{sub 3}Sn superconductor, is under development at Fermilab, for a future Very Large Hadron Collider. This magnet has some innovative design and technological features such as single layer coils, a 22 mm wide 60-strand Rutherford type cable and stainless steel collars reinforced by horizontal bridges inserted between coil blocks. Both left and right coils are wound simultaneously into the collar structure and then impregnated with epoxy. In order to optimize the design and fabrication techniques an R&D program is underway. The production of cables with the required characteristics was shown possible. Collar laminations were produced, assembled and tested in order to check the effectiveness of the bridges and the validity of the mechanical design. A mechanical model consisting of a 165 mm long section of the magnet straight section was assembled and tested. This paper ...
2002-01-14
Energy Technology Data Exchange (ETDEWEB)
This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection and detection scheme was developed for use ...
1982-10-01
Use of hydrolyzed polyacrylonitrile for limiting the influxes of water at the Sokolovgoroskiy field
Energy Technology Data Exchange (ETDEWEB)
A formula and technology are presented for the preparation of a hydrolyzed polyacrylonitrile (gipane) from the wastes of chemical production, analysis of the results of working to use them to insulate influxes of water in the extracting wells of the Sokolovogorskiy field.
1980-01-01
UK PubMed Central (United Kingdom)
The Sleeping Beauty (SB) transposon system represents an important alternative to viral integrating vector systems but may, as its viral counterparts, be subject to transcriptional silencing. To investigate...Full Text Available
2009-01-01
PWR primary circuit piping installation of Daya Bay Nuclear Power Plant
International Nuclear Information System (INIS)
The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.
Energy Technology Data Exchange (ETDEWEB)
A non-synthetic polymer material, polyterpenol, was fabricated using a dry polymerization process namely RF plasma polymerization from an environmentally friendly monomer and its surface, optical and electrical properties investigated. Polyterpenol films were found to be transparent over the visible wavelength range, with a smooth surface with an average roughness of less than 0.4 nm and hardness of 0.4 GPa. The dielectric constant of 3.4 for polyterpenol was higher than that of the conventional polymer materials used in the organic electronic devices. The non-synthetic polymer material was then implemented as a surface modification of the gate insulator in field effect transistor (OFET) and the properties of the device were examined. In comparison to the similar device without the polymer insulating layer, the polyterpenol based OFET device showed significant improvements. The addition of the polyterpenol interlayer in the OFET shifted the ...
2010-08-31
Energy Technology Data Exchange (ETDEWEB)
Cited are the results of physico-chemical studies and industrial tests of a copolymer of methacrylic acid and diethylammonium salt, used for limiting the influx of stratum waters into a well.
1981-01-01
Cavity detection by the electric method: the 3-dimensional case
Energy Technology Data Exchange (ETDEWEB)
In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)
2004-02-01
Carbon-bonded carbon fiber insulation for radioisotope space power systems
Energy Technology Data Exchange (ETDEWEB)
A carbon-bonded carbon fiber (CBCF) insulation developed for a radioisotope heat source is made from chopped rayon fiber about 10..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF is an excellent lightweight insulating material with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W/(m-K) in vacuum at 2000/sup 0/C. (Several attributes that make CBCF particularly suitable for the heat source application have been identified.) These include light weight, low thermal conductivity, chemical compatibility, and hightemperature capabilities. The mechanical strength of CBCF insulation is satisfactory for the application. The basic fabrication technique was refined to eliminate undesirable large pores and cracks often present in materials fabricated by earlier techniques. Also, processing was scaled up to increase the fabrication rate by a factor of 10. The specific properties ...
1985-05-01
Carbon-bonded carbon fiber insulation for radioisotope space power systems
Energy Technology Data Exchange (ETDEWEB)
A carbon-bonded carbon fiber (CBCF) insulation developed for a radioisotope heat source is made from chopped rayon fiber about 10 ..mu..m in diameter and 250 ..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF is an excellent lightweight insulating material with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W/(m-K) in vacuum at 2000/sup 0/C. Several attributes that make CBCF particularly suitable for the heat source application have been identified. These include light weight, low thermal conductivity, chemical compatibility, and high-temperature capabilities. The mechanical strength of CBCF insulation is satisfactory for the application. The basic fabrication technique was refined to eliminate undesirable large pores and cracks often present in materials fabricated by earlier techniques. Also, processing was scaled up to increase the fabrication rate by a factor of ...
1985-05-01
Loading of wellbores with explosives
Energy Technology Data Exchange (ETDEWEB)
Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube when the latter is raised to the surface is assured by threading the cord through plastic tubing mounted to the wall of the ...
1983-04-26
Light weight underground pipe or cable installing device
Energy Technology Data Exchange (ETDEWEB)
This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.
1985-01-08
Electrical Transmission Line Diametrical Retention Mechanism
The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.
2006-01-03
Design of Reactor Head Structure Assembly Using Axiomatic Design
Energy Technology Data Exchange (ETDEWEB)
The Reactor Head Structure Assembly(RHSA) is the structure located on the reactor assembly. The purpose of the assembly is providing interface location for cables, preventing pipe whips, prohibiting instruments from becoming missiles, and restraining CEDMs' horizontal motion. On the RHSA, Reactor Disconnect Panels(RDP) are installed. The installation location of RDP is to be decided to minimize the geometric interface with other components. Since the neighborhood of RHSA is crowded due to many connectors and cables, it is necessary to find the good design of RHSA to make an intricate situation attenuated and the required function maintained. The geometric shape and overall configuration of RHSA are determined by axiomatic design approach. The FRs of RHSA are specified and the corresponding DPs are found to satisfy FRs in sequence. The finite element analysis is carried out based on the result of the axiomatic design to evaluate the ...
2007-07-01
The application of advanced techniques for complex focused-ion-beam device modification
Energy Technology Data Exchange (ETDEWEB)
Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).
1996-12-31
Structural engineering and noise pollution abatement. Improvements that can be measured
Energy Technology Data Exchange (ETDEWEB)
Structural engineering implies four factors particularly relevant to sonics: airborne noise abatement, insulation of plumbing, by-pass insulation and noise absorption (noise abatement). These are exemplified with special regard to methodical and/or product-specific noise pollution abatement measures. Besides, reference is made to DIN standards 4109 providing both engineers with practical advice and pipe fitters or plumbers with concrete examples for application. VDI recommendations 3733 convey essential knowledge of how to properly apply sonic principles in the planning, design and installation of pipes. (BR).
1985-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
Probability distributions of partial discharge (PD) and dielectric breakdown voltage were investigated for the typical components of oil-filled transformer insulation. The equi-probabilistic PD and BD V-t characteristics were obtained from experimental results in the time range from several ..mu..sec to 10 hours. The authors point out that there is a close relationship between the scattering of PD voltage and the inclination of V-t characteristics in a long term region for ac voltage.
1982-08-01
Method of forming solar cells by grid contact isolation
Energy Technology Data Exchange (ETDEWEB)
A solar cell structure is produced by a method comprising baking the solar cell, containing a gridded top layer of cuprous sulfide formed on a base of cadmium sulfide, for 20 minutes to 10 hours, to produce a copper doped cds electrically insulating region in the cadmium sulfide base near the interface of the cuprous sulfide and the cadmium sulfide; removing the cuprous sulfide, and the copper doped cds insulating region not covered by the grid, to provide a bare cadmium sulfide areas; and then forming a cuprous sulfide layer on the exposed areas not covered by the grid.
1982-03-16
Ionizing radiation hardening procedure of CCD's
International Nuclear Information System (INIS)
The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.
Hybrid solar/combustion powered receiver
Energy Technology Data Exchange (ETDEWEB)
An improved hybrid solar/combustion powered receiver of the type having an insulated housing with a front end and a rear end, a heat exchanger positioned adjacent the rear housing end for extracting heat energy out of the receiver, the insulated housing surrounding the heat exchanger and forming a receiver cavity, the housing also including an aperature having an aperture axis, the aperture located in the front housing end for admitting solar radiation to the cavity to impinge upon the heat exchanger, and a plurality of gas burners to provide combustion gases within the receiver.
1986-07-29
Gases in insulating oil - analysis of dissolved gases using a portable chromatograph
Energy Technology Data Exchange (ETDEWEB)
New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
The General-Purpose Heat Source (GPHS), an improved radioisotope heat source, employs a unique thermal insulation material, carbon-bonded carbon fiber (CBCF), to protect the fuel capsule and to help achieve the highest possible specific power. The CBCF insulation is made from chopped rayon fiber about 10 ..mu..m in diameter and 250 ..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF shapes, both tubes and plates, are formed in a multiple molding facility by vacuum molding a water slurry of the carbonized chopped-rayon fiber (54 wt %) and phenolic resin (46 wt %). The molded shapes are subsequently dried and cured. Final carbonization of the resin is at 1600/sup 0/C. Machining to close tolerances (+-0.08 mm) is accomplished by conventional tooling and fixturing. The resulting material is an excellent lightweight insulation with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity ...
1985-06-01
Tritium contamination and decontamination study on materials for ITER remote handling equipment
Energy Technology Data Exchange (ETDEWEB)
Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO{sub 2} containing alkaline barium glass (NB), CeO{sub 2} containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm{sup 2}, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm{sup 2}, respectively. The tritium concentration in an electric ...
2001-09-01
Tritium contamination and decontamination study on materials for ITER remote handling equipment
International Nuclear Information System (INIS)
Several materials, lenses, dry bearings and cables were exposed to a tritiated moisture environment to study the behavior of tritium contamination on candidate materials for ITER remote handling equipment. To optimize the tritium removal procedure, decontamination experiments using a gas purge with three different moisture concentrations were also performed. The surface tritium concentrations of CeO_2 containing alkaline barium glass (NB), CeO_2 containing lead glass (LX) and synthetic quartz (Quartz) after the exposure experiments were 7.80, 10.94 and 0.67 Bq/cm"2, respectively. It was found that the tritium concentration was influenced by the compositions of the materials. The concentrations of tritium on type 831 (solid lubrication material: graphite) and type 237 (solid lubrication material: tungsten disulfate) dry bearings after the exposure experiments were 89.80 and 31.78 Bq/cm"2, respectively. The tritium concentration in an electric ...
2001-09-01
Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies
Energy Technology Data Exchange (ETDEWEB)
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed ...
1983-12-01
Revolutionary news on superconductivity
Energy Technology Data Exchange (ETDEWEB)
A brief article gives an update on the commercial exploitation of superconductivity by the American Superconductor Corporation. Potential applications include transmission and distribution, motors, magnetic storage systems, current limiters and transport. The company have produced a kilometre long, ''wrappable'' cable capable of carrying thousands of amps when operating at a temperature of below -140[sup o]C. (UK)
1994-09-01
Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen
International Nuclear Information System (INIS)
For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.
2009-11-01
Oceans 82 conference record: Industry, government, education. partners in progress
Energy Technology Data Exchange (ETDEWEB)
Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.
1982-01-01
Interconnection France-England; Interconnexion France-Angleterre
Energy Technology Data Exchange (ETDEWEB)
These documents defines the interconnection France-England rules for the 2000 MW DC submarine cable directly linking the transmission networks of England and Wales and France. Rights to use Interconnector capacity from 1 April 2001 are to be offered through competitive tenders and auctions, full details of which are set out in the Rules. The contract and a guide to the application form are provided. (A.L.B.)
2001-07-01
Electrical equipment of the Marchtrenk power station on the river Traun
Energy Technology Data Exchange (ETDEWEB)
By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.
1982-03-01
Energy Technology Data Exchange (ETDEWEB)
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
1988-10-14
Development of 345-kV capacitive-graded joint. Final report
Energy Technology Data Exchange (ETDEWEB)
The design of a 345-kV prefabricated capacitive-graded joint for oil-filled cables and the manufacture and testing of prototype joints are described. Tests on prototype No. 4 demonstrated the adequacy of the printed circuit design. It was not possible to consistently obtain high-quality capacitive sheets and substantial effort is required to remedy this problem. Advantages of these prefabricated joints are summarized, and specific recommendations are made for further development of the concept.
1980-09-01
Energy Technology Data Exchange (ETDEWEB)
Corona from bare conductors of electrical overhead power lines is studied in this article. Its origin, as well as, its bad influences over communication systems are both studied, yet. Line`s models are defined, in order to be able the examination of Corona on line`s cables. Formulas for the surface electrical gradient calculations are shown. (author) 2 refs.
1993-12-01
An analysis of selected atmospheric icing events on test cables
Energy Technology Data Exchange (ETDEWEB)
In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing events can produce large ice accretions dangerous for land-based structures. They are rime due to in-cloud icing, glaze caused by freezing rain, wet snow, and mixtures of ...
1996-12-01
A HELICAL MAGNET DESIGN FOR RHIC.
Energy Technology Data Exchange (ETDEWEB)
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
1997-05-12
Scour protection for wind turbine foundations on highly erodible sea bottom
Energy Technology Data Exchange (ETDEWEB)
Scour around offshore structures is well known. It is caused by the strong eddy formation at the base of the structures protruding from the sea bottom. The strong vortices result in an amplified effective shear stress working on the sea bottom surface adjacent to the structure. When the surrounding sea bottom is lowered the scour protection will end up being a cap on a small hill and when the slopes are getting too steep the scour protection will roll or slide down the sides. It will loose its cohesion and therefore its integrity. This will take place irrespective of the type of scour protection material and the type of scour protection. This report describes scour protections, which can deal with this particular problem. Such a scour protection must be able to sustain the following loads: Be able to follow the lowering of the seabed on its way down; Be resistant to edge scour (scour around the perimeter of the scour protection). The installation of scour protection is not ...
2002-12-01
International Nuclear Information System (INIS)
Insulitis is considered the histopathological hallmark of type I diabetes. In the non-obese diabetic (NOD) mouse, diabetes has never been observed in the absence of insulitis. The in vivo detection of insulitis could be of relevance for early prediction of diabetes. As approximately 15% of islet-infiltrating lymphocytes express interleukin 2 receptors, the authors have labelled recombinant inter-leukin 2 with "1"2"3I and used this radiopharmaceutical to detect insulitis by gamma camera imaging. The authors studied 71 prediabetic NOD and 27 normal Balb/c mice. Labelled #alpha#-lactalbumin was used as the control protein. In the first set of experiments the tissue distribution of radiolabelled interleukin 2 in isolated organs from animals sacrificed at different time points was studied. Higher radioactivity was detected in the pancreas of NOD mice injected with labelled interleukin 2, as compared to NOD ...
1994-01-01
Methods for evaluating long-term changes in thermal resistance of vacuum insulation panels
Energy Technology Data Exchange (ETDEWEB)
Vacuum insulation panels (VIP) offer excellent thermal resistance properties that can enhance the energy efficiency of insulating systems, save space and contribute to energy consumption reductions. However, VIPs are not used much in Canada, and new commitments to carbon dioxide reductions has created the need to study the prospect of using VIPs in various components of a building envelope. For that reason, assessment methods for the applicability and sustainability of VIPs for use in building envelope construction were developed. There are practical aspects regarding the long-term performance and application of VIPs in building construction. Air molecules and water molecules can permeate through the foil and seams of the VIPs, causing a reduction in thermal resistance. This paper addresses some of the test methods that may accelerate long term changes in thermal resistance. Results were presented from tests using elevated pressure, relative ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
This paper extends the analytical procedure described in another paper in these proceedings to analyze a variety of compact and light-weight OSC-designed radioisotope-heated generators. Those generators employed General Purpose Heat Source (GPHS) modules and a converter containing sixteen AMTEC cells of OSC`s revised five-tube design with enhanced cell wall reflectivity described in a companion paper in these proceedings. OSC found that the performance of the generator is primarily a function of the thermal insulation between the outside of the generator`s 16 cells and the inside of its wall. After examining a variety of insulation options, it was found that the generator`s performance is optimized by employing a hybrid insulation system, in which the space between the cells is filled with fibrous Min-K insulation, and the generator walls are lined with tapered (i.e., graded-length) multifoil ...
1997-12-31
Production of intense negative ion beams in magnetically insulated diodes
Energy Technology Data Exchange (ETDEWEB)
Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were usually emitted from a few hot spots on the cathode surface. ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm{sup 2}. Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used ...
1990-06-01
Near-infrared photodetectors based on mercury indium telluride single crystals
Attempt to form the Schottky barrier on mercury indium telluride (MIT) surface by deposition transparent conducting electrode (TCE) and avoid the negative results by non-rectifier contacts nature, we have investigated the oxidation of clean MIT surfaces to form an insulating layer to overcome this disadvantage by metal-insulator-semiconductor (MIS) photodetectors designing. Oxide film is grown on the MIT surface by plasma enhance chemical vapor deposition (PECVD). Previously cleaned MIT wafers were dipped and boiled in solution, which consists of mixture of bromine and an organic solvent in ratio of 1:50. By the way of using these films as intermediate slightly conducting insulator, a fast-response MIT based surface-barrier photodetectors have been developed. Pt films were used as TCE frontal electrode by vacuum magnetron sputtering (VMS). The current-voltage characteristic is described quantitatively based on the energy ...
2008-03-01
International Nuclear Information System (INIS)
Heat losses in duct flow and heat transfer enhancement are investigated through an analysis of natural convection about a horizontal cylinder with a porous or fibrous coating. The porous substrate may be used for two purposes. According to its properties, it may be employed as an insulating material or as a means to surface augmentation. An optimization study is then carried out in order to find the best conditions that allow good thermal insulation or heat transfer rate improvement. The flow motion and heat transfer coefficient are predicted for various conditions. The results show that an efficient insulation which means less than 10% in heat losses is obtained for a porous layer thickness of 0.8x tube diameter and a permeability corresponding to Da #<=# 10"-"7. Nevertheless, there is a Darcy number limit above which convection must be accounted for. Porous or fibrous materials may also be used as a heat transfer ...
2007-06-01
International Nuclear Information System (INIS)
A laminated material composed of glass cloth/polyimide film/epoxy resin will be used as an insulating material for superconducting coil of International Thermonuclear Experimental Reactor (ITER). In order to keep safe and stable operation of the superconducting coil system, it is indispensable to evaluate radiation resistance of the material, because the material is exposed to severe environments such as high radiation field and low temperature of 4 K. Especially, it is important to estimate the amount of gases evolved from the insulating material by irradiation, because the gases affect on the purifying system of liquid helium in the superconducting coil system. In this work, the gas evolution from the laminated material by gamma ray irradiation at liquid nitrogen temperature (77 K) was investigated, and the difference of gas evolution behavior due to difference of composition in the epoxy resin was discussed. It was found that the main gases ...
2008-03-03
Entanglement Spectrum of a Disordered Topological Chern Insulator
How much information is stored in the ground-state of a system without \\emph{any symmetry} and how can we extract it? This question is investigated by analyzing the behavior of a topological Chern Insulator (CI) in the presence of disorder, with a focus on its entanglement spectrum (EtS) constructed from the ground state. For systems with symmetries, the EtS was shown to contain explicit information revealed by sorting the EtS against the conserved quantum numbers. In the absence of any symmetry, we demonstrate that statistical methods such as the level statistics of the EtS can be equally insightful, allowing us to distinguish when an insulator is in a topological or trivial phase and to map the boundary between the two phases, where EtS becomes entirely delocalized. The phase diagram of a CI is explicitly computed as function of Fermi level ($E_F$) and disorder strength using the level statistics of the EtS and energy spectrum (EnS), ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The methodology of the drip procedure of the Standard Test Method for Evaluating the Influence of Thermal Insulation on External Stress Corrosion Cracking Tendency of Austenitic Stainless Steel (ASTM C 692-95a) was used to research the effect of halogens and inhibitors on the external stress corrosion cracking (ESCC) of Type 304 stainless steel as it applies to the insulation industry. Simulated insulation extraction solutions were made with pure chemical reagents for the halogens and inhibitors. The results indicated that sodium silicate compounds that were higher in sodium were more effective for preventing chloride-induced ESCC in Type 304 austenitic stainless steel. Potassium silicate was not as effective as sodium silicate. Fluoride, bromide, and iodide may cause ESCC but they were much less active than chloride and could be effectively inhibited by sodium silicate compound. The addition of fluoride ions to the ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. ...
2009-06-17
A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator
Energy Technology Data Exchange (ETDEWEB)
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault ...
2007-10-29
US Army workshop on low-heat-rejection engines (4th). Summary of presentations 29-31 March 1989
Energy Technology Data Exchange (ETDEWEB)
This paper describes the basic principles underlying the operation of low heat loss engines and the magnitude of the efficiency improvements that are theoretically achievable. The effect of varying degrees of thermal insulation on various operating parameters is examined in some detail, as is the relationship between degree of insulation and ceramic coating thickness. The effect on ceramic materials of severe surface temperature oscillations and the resultant thermal stress gradients is also discussed. In the following section, the paper describes methods of construction adopted both for ceramic inserts and coatings, and rig tests for the assessment of thermal fatigue under both load and firing cycling. The paper does not attempt to draw any general conclusions.
1989-03-31
Tunneling magnetoresistance from a symmetry filtering effect
International Nuclear Information System (INIS)
This paper provides a brief overview of the young, but rapidly growing field of spintronics. Its primary objective is to explain how as electrons tunnel through simple insulators such as MgO, wavefunctions of certain symmetries are preferentially transmitted. This symmetry filtering property can be converted into a spin-filtering property if the insulator is joined epitaxially to a ferromagnetic electrode with the same two-dimensional symmetry parallel to the interface. A second requirement of the ferromagnetic electrodes is that a wavefunction with the preferred symmetry exists in one of the two spin channels but not in the other. These requirements are satisfied for electrons traveling perpendicular to the interface for Fe-MgO-Fe tunnel barriers. This leads to a large change in the resistance when the magnetic moment of one of the electrodes is rotated relative to those of the other electrode. This large tunneling magnetoresistance effect is ...
2008-04-01
British Library Electronic Table of Contents (United Kingdom)
Premature Failure of a Riata Defibrillator Lead. A 63-year-old woman with a St. Jude Medical Riata 1570 right ventricular lead complained of intermittent hiccups 2 months after implant. Interrogation revealed elevated pacing threshold and diaphragmatic stimulation. Pacing and shock lead impedances remained stable. No inappropriate sensing was noted. Fluoroscopic examination of the lead revealed a thin radio-opaque wire seen between the 2 defibrillator coils away from the main body of the lead. After extraction, a tear in the insulation of the lead was noted allowing the inner wire to protrude. This case illustrates a novel mechanism of insulation failure without inappropriate sensing or impedance change.-(J Cardiovasc Electrophysiol, Vol. 22, pp. 1070-1072, September 2011)
2011-01-01
International Nuclear Information System (INIS)
Pre-amorphization of ultrashallow implanted boron in Silicon-on-insulator is optimized to produce an abrupt box-like doping profile with negligible electrical deactivation and significantly reduced transient enhanced diffusion. The effect is achieved by positioning the as-implanted amorphous/crystalline interface close to the buried oxide interface, to minimize interstitials whilst leaving a single-crystal seed to support solid-phase epitaxy. Based on a simple physical model of our results, we estimate that the interface between the Si overlayer and the buried oxide is an efficient interstitial sink with a recombination length of the order of 10nm or less under our experimental conditions. (author)
2008-12-01
(TSM-TTP)(I3)5/3 is a 1/6 -filled one-dimensional system composed of an extended donor molecule which has two tetrathiafulvalene (TTF) units in a molecule, where TSM-TTP is 2,5-bis[4,5-bis(methylseleno)-1,3-dithiol-2-ylidene]-1,3,4,6-tetrathiapentalene. Nonlinear conductivity is observed in the insulating state below 20K , and the metallic state is restored above a very small threshold electric field of 0.3V/cm at 4.2K . The extremely sensitive nonlinearity is ascribed to the inhomogeneous insulating state generated by the weak and disordered anion potentials on the otherwise highly conducting intramolecular charge order state in the double-TTF molecule.
2007-06-01
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
Energy Technology Data Exchange (ETDEWEB)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator
International Nuclear Information System (INIS)
The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.
2004-12-15
Energy Technology Data Exchange (ETDEWEB)
Mechanical ventilation in private homes was for many years a stepchild of air conditioning engineers. A decisive impulse for change came in January 1995 with the enactment of the new Thermal Insulation Ordinance which for the first time allows house owners to exceed the usual admissible annual heating requirement by a certain amount on the condition that they equip the house with mechanical ventilation systems. (orig.) [Deutsch] Ueber lange Jahre war die mechanische Wohnungslueftung ein Stiefkind der Raumlufttechnik. Einen entscheidenden Impuls gab erst die seit Januar 1995 gueltige Waermeschutzverordnung, die erstmals zulaesst, dass ein gewisses Quantum des Jahres-Heizwaermebedarfs durch den Einbau mechanischer Wohnungslueftungen kompensiert werden kann. (orig.)
1996-10-01
Forced convective heat transfer in cross-corrugated solar air heaters
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the Reynolds number.
1994-11-01
International Nuclear Information System (INIS)
There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.
2007-02-07
Characterization of vacuum-multifoil insulation for long-life thermal batteries
Energy Technology Data Exchange (ETDEWEB)
The use of vacuum multifoil (VMF) container for thermal insulation in long-life thermal batteries was investigated in a proof-of-concept demonstration. An InvenTek-designed VMF container 4.9 inches in diameter by 10 inches long was used with an internally heated aluminum block, to simulate a thermal-battery stack. The block was heated to 525 C or 600 C and allowed to cool while monitoring the temperature of the block and the external case at three locations with time. The data indicate that it should be possible to build an equivalent-sized thermal battery that should last up to six hours, which would meet the requirements for a long-life sonobuoy application.
2000-04-17
Energy Technology Data Exchange (ETDEWEB)
In this work, we investigated self-heating related instability in polysilicon thin film transistors (poly-Si TFTs) fabricated on polyimide (PI) substrates. Indeed, when Joule heating becomes relevant, the temperature of the active layer can substantially rise, since the devices are fabricated on thermally insulating substrates. As a result, electrical instability is triggered and attributed to the generation of interface states, due to the Si-H bond breaking, and charge trapping into the gate insulator. In addition, by using 3-dimensional numerical simulations, coupling the thermodynamic and transport models, we analyzed the temperature distribution of the device under operating conditions and found that self-heating is more severe for devices fabricated on plastic substrates.
2009-10-01
British Library Electronic Table of Contents (United Kingdom)
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Radon proof barriers are used for lowering of radon transport from the soil into the house and the determination of the radon diffusion coefficient is an important parameter to be determined in order to design the minimal thickness of the radon proof insulation. A method has been developed in our laboratory by using modified Lucas cells connected to a radon source and tightly closed onto the top by the tested membranes whose radon diffusion coefficients are being measured. Solving the time-dependent differential equation for radon diffusion in the membrane for well-defined experimental conditions the effective radon diffusion coefficient of the insulating material can be evaluated by comparing the radon concentration decrease in the cell for the first hours with the well-known radioactive decay. First results obtained in several preliminary tests carried out with a parafilm M barrier and two polyethylene membranes are shown in this paper.
2005-01-01
Transient overvoltages and overcurrents during line fault tests on the Hokkaido-Honshu HVDC line
Energy Technology Data Exchange (ETDEWEB)
A series of line fault tests have been conducted at completion of Stage I of the Hokkaido-Honshu HVDC Link of Electric Power Development Co., Ltd., prior to its commercial operation, in order to study transient overvoltages and overcurrents and to confirm safety operation of system protecting devices in case of DC transmission line faults. The Hokkaido-Honshu HVDC Link is a metallic return HVDC overhead line and cable transmission system, currently being a monopolar system. For this, measurements were conducted this time on reverse polarity overvoltages occurring on main line cable, return line overvoltages, fault arc dynamic characteristics, and DC bypass current through the AC system. The results obtained were then compared with the analysis results by the HVDC surge similator or digital simulation conducted for system design prior to the field tests. As a result, a close accordance was found between them, in confirmation of the effectiveness ...
1982-08-01
The Schenberg spherical antenna: status report
International Nuclear Information System (INIS)
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...
2009-09-14
Structural design and fabrication of the Sandia 34-meter Vertical Axis Wind Turbine
The Wind Energy Research Division of Sandia National Laboratories has been funded by the Wind/Ocean Technology Division of the Department of Energy (DOE) to design and build a 34-meter diameter Vertical Axis Wind Turbine (VAWT). The turbine design incorporates the results of recent VAWT research in aerodynamics and structural dynamics. Initial system concept studies identified several blade options that met the required power rating of 500 kW. The final blade and rotor configurations were chosen based on finite element calculations that determined the turbine modes of response, their frequency of vibration, and stress levels. For parked survival turbine components were designed to with stand the loading of a 150 mph (67.0 m/s) wind coupled with maximum cable tensions. Specific areas of design discussed include the rotor, cables, bearings, brakes, and foundations. Construction of the turbine is in progress at this time and anticipated completion ...
1987-01-01
The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be ...
2004-01-01
Nb{sub 3}Sn LLNL cable test strand
Energy Technology Data Exchange (ETDEWEB)
Axial strain characterization was completed for a Nb{sub 3}Sn conductor from Lawrence Livermore National Lab used in a transverse stress test of a cable-in-conduit conductor. The effect of axial strain on the critical current of the LLNL Nb{sub 3}Sn test strand was measured at magnetic fields from 8 T to 22 T. The conductor specifications are shown in Table 3, and the measured data are shown in Table 4. The data are presented graphically in Figs. 5 through 7. The I{sub c} and J{sub c} values are based on an electric field criterion (E{sub c}) of 2 {mu}V/cm. The zero-strain 12 T value of J{sub c} at 12 T was 0.39 GA/m{sup 2}. The irreversible strain limit was quite high, 1.0 strain, and the compressive prestrain was relatively low at 0.27%. Fracture strain was 1.10%.
1994-01-01
Low-cost FPSO for service in the Zaafarana oil field
Energy Technology Data Exchange (ETDEWEB)
The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced estimate, combined with a revised pricing ...
1997-04-01
Dynamic Rating and Underground Monitoring System (DRUMS)
Energy Technology Data Exchange (ETDEWEB)
Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable system. Mechanical Communication will use pressure pulses to transmit data along the system, while the ...
1991-07-01
Underground electric-power transmission-system environmental impact assessment
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy, Division of Electric Energy Systems, has undertaken to identify the environmental issues and potential impacts associated with the installation of underground electric power transmission systems. This study reports the results of investigations into the advanced cable technologies being considered for future underground applications, as part of the development oriented research program of the Division of Electric Energy Systems. While the technology involves a high level of sophistication, there are relatively few impacts to the environment that are potentially significant, and of these none are inherently non-mitigable. Route planning, system design, and methods of construction and accident response can be pursued in order to minimize impacts where strict constraints are appropriate.
1982-03-01
Selected topics in transient response of aerial lines to high-altitude electromagnetic pulse
International Nuclear Information System (INIS)
Aerial lines or cables, as one mainly energy transport path of electronic system when illuminated by HEMP, has been often modeled by field-to-transmission line model. However, in many cases, authors too often encounter some confusing statements to the lines effects during experimental procedure. The aim of this paper is to present and discuss these cases, such as the electromagnetic environment above the ground plane, the contribution of the different electromagnetic field component to the induced current and voltage, variations of the load current for different line heights and ground conductivities etc. (authors)
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
This article gives a survey of the history, properties and applications of 'Kevlar' aramide fibers. For example, the 'Kevlar' para-aramide fiber is used in compound materials in ship-, aircraft- and vehicle construction. 'Kevlar' is used as a replacement for asbestos, for example in brakes, clutches and seals or as rubber reinforcement (tyres, conveyor belts, hoses). The aramide fibers also offer manufacturers of ropes, hawsers and cables a near ideal range of properties. (MM).
1988-12-01
Industrial processing of complex fluids: Formulation and modeling
Energy Technology Data Exchange (ETDEWEB)
The production of many important commercial materials involves the evolution of a complex fluid through a cooling phase into a hardened product. Textile fibers, high-strength fibers(KEVLAR, VECTRAN), plastics, chopped-fiber compounds, and fiber optical cable are such materials. Industry desires to replace experiments with on-line, real time models of these processes. Solutions to the problems are not just a matter of technology transfer, but require a fundamental description and simulation of the processes. Goals of the project are to develop models that can be used to optimize macroscopic properties of the solid product, to identify sources of undesirable defects, and to seek boundary-temperature and flow-and-material controls to optimize desired properties.
1997-08-01
Electromagnetic coupling of high-altitude, nuclear electromagnetic pulses
International Nuclear Information System (INIS)
We have used scale models to measure the predicted coupling of electromagnetic fields simulating the effects of high-altitude nuclear electromagnetic pulses (HEMP) on the interior surfaces of electronic components. Predictive tools for exterior coupling are adequate. For interior coupling, however, such tools are in their infancy. Our methodological approach combines analytical, computational, and laboratory techniques in a complementary way to take advantage of their separate strengths. Computer models are a promising tool, as they can be used to treat complex objects with arbitrary shapes, dielectrics, and cables, and multiple apertures. Laboratory tests can expand the domain of investigation even further.
1984-11-01
An estimate of the response of a telephone repeater to a wideband pulse using FAAT techniques
Energy Technology Data Exchange (ETDEWEB)
The purpose of a FAAT analysis is to estimate the probability of system upset to an electromagnetic threat, for systems on which we have incomplete information. As an example of this process, we will discuss the response of part of a telephone repeater system to wideband transients. We first estimate the currents induced on above-ground and buried cables. After that, we describe the simple circuit we used to build a model of the amplifier and protective devices. Finally, we describe the scaling of the energy deposited in the electronics, including its nonlinear large-signal response, with the amplitude of the wideband waveforms.
1992-09-01
A. C. losses in the SSC high energy booster dipole magnets
Energy Technology Data Exchange (ETDEWEB)
The baseline design for the SSC High Energy Booster (HEB) has dipole bending magnets with a 50 mm aperture. An analysis of the cryogenic heat load due to A.C. losses generated in the HEB ramp cycle are reported for this magnet. Included in this analysis are losses from superconductor hysteresis, yoke hysteresis, strand eddy currents, and cable eddy currents. The A.C. loss impact of 2.5 {mu}m vs. 6 {mu}m filament conductor is presented. A 60 mm aperture design is also investigated. 8 refs., 3 tabs.
1991-06-01
2000 MW HVDC link between England and France
Energy Technology Data Exchange (ETDEWEB)
The HVDC link across the English Channel, which was brought into service in 1986, has several innovative features. Techniques used in its construction together with recent developments have consolidated the viability of HVDC links for a variety of applications. Outlines the main features of the scheme, including the benefits of interconnecting the British and French 400 kV AC power systems; integration of the UK converter system to the 400 kV AC grid; the DC submarine cables; convertor equipment (particularly the UK installation); and future HVDC developments. 6 refs.
1987-03-01
Energy Technology Data Exchange (ETDEWEB)
Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in this report. Also a summary of results from ...
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)
2006-07-01
Tunneling spectroscopy of anisotropic superconductors
Energy Technology Data Exchange (ETDEWEB)
Tunneling spectroscopy of normal-insulator-superconductor junction is investigated theoretically. In anisotropic superconductors, differently from the case of isotropic superconductor, the effective pair potentials felt by quasiparticles depend on the direction of their motion. By taking this effect into account, it is shown that the conductance spectra strongly depend on the crystal orientation. Using Green`s function method, local density of states (LDOS) in superconductor is also calculated. The close relation between conductance spectra and LDOS is presented. The calculation is compared with experimental spectra of high-{Tc} superconductors.
1996-12-31
The adiabatic engine:Global developments
Energy Technology Data Exchange (ETDEWEB)
This book presents papers on internal combustion engines. Topics considered include the influence of partial suppression of heat rejection on performance and emissions, duothermic combustion, turbochargers made of sintered silicon nitrides, heat flux, low heat rejection engines, exhaust energy recovery, combustion chamber insulation, computerized simulation, heat transfer, friction, hoop stress effects, and bonding ceramics and metals.
1986-01-01
International Nuclear Information System (INIS)
Vacuum glazing consists of an evacuated space between two sheets of glass. Vacuum glazing has a large effect on energy savings in houses and buildings. Vacuum glazing can achieve higher insulating performance than conventional insulated glazing. Nippon Sheet Glass has successfully developed conventional vacuum glazing. In this study we investigated an advanced form of vacuum glazing. Its thermal insulation ability is equivalent to 100 mm thick glass wool thermal insulation. This vacuum glazing contained a SnO_2:F low emissivity surface. The influence of the residual gas in a vacuum space on heat flow is important to performance. For long-term thermal stability, it is very important to maintain vacuum stability. To understand this better, we studied the behavior of outgassing from the inside glass surfaces exposed to an external energy source. We have studied the behavior of outgassing from a glass ...
2005-06-15
... The composite ground floor is suitable for support to all types of wall construction and can be used equally well on strip footings or mini-pile foundations . The light steel edge beams provide the accurate template required for internal timber or light steel wall frames to minimise fitting time and eliminate rework. The floated slab surface will accept floor finishes directly and thermal insulation can be easily fitted beneath ...
Simplified methods in the estimation of the K-value of insulated cargo holds on ships
Energy Technology Data Exchange (ETDEWEB)
The problem of buried steelwork in cargo hold insulation has been investigated by several using empirical methods. These efforts have resulted in correction factors that serve as a useful aid in the complex task of estimating the K-value of a ship`s cargo holds for the correct dimensioning of the refrigeration plant. Today, the advent of the digital computer has established numerical methods of analysis as a common working tool among practicing engineers. For estimating the flow in cases of buried steelwork that cannot be handled by correction factors, this is an effective approach. This study is an analytical/numerical investigation of the effect that buried steelworks have on the heat leakage across cargo hold walls. It aims at providing enlightenment on the physical significance of the parameters influencing the problem and developing practically simple methods for predicting the heat leakage across the hold walls. The study is set in the steady temperature in a ...
1992-03-01
Silicon electrochemistry related to the formation of porous silicon
Energy Technology Data Exchange (ETDEWEB)
We have examined in detail the electrochemistry of both n- and p-type single crystal (100) silicon in the porous silicon formation regime using a rotating Si disk apparatus with a Ag/AgCl reference electrode. Our findings impact the use and optimization of buried n- or p-type layer anodization for silicon-on-insulator (SOI) wafer synthesis. Results are briefly discussed. 3 refs.
1988-01-01
Preliminary study on the dielectric constant of WPC based on some tropical woods
Energy Technology Data Exchange (ETDEWEB)
The use of WPC as an important insulating material is studied by determining its dielectric constant. The variation of dielectric constant with moisture content is also investigated. Preliminary results show that all untreated woods studied have a higher dielectric constant than their polymer composites with the exception of Kapur and Keruing. It is therefore postulated that the presence of polymers has led to a decrease in the number of polarizable units. Such a material may be useful commercially.
1986-01-01
Piezoelectrics based on a hybrid of piezoelectric matrix nano- and microcomposites
British Library Electronic Table of Contents (United Kingdom)
The physics and technology of a new class of efficient composite piezoelectrics are described. This material combines nanostructured and micropiezoelectric matrix composites. They consist of a polymer matrix, an insulating nanodimensional phase, and a microdimensional piezoelectric phase. It is shown that the nanostructuring of the near-surface region of polymer-PZT piezoelectric composites greatly improves their piezoelectric, mechanical, and electromechanical characteristics. A plausible mechanism underlying this effect is suggested.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents the experimental measurements of the transmittivity of commercial grade stearic acid. The effects of temperature and thickness on transmittance have been studied. The study indicates that the effect of temperature on the transmittance of stearic acid in the liquid phase is not significant. However, it is highly dependent on temperature during the solidification process. Because of its low thermal conductivity and high transmittivity, it can be used as a transparent insulating material. (Author)
1999-12-01
International Nuclear Information System (INIS)
Large, complex, high purity ceramic shapes are required by a variety of emerging technologies for their electrical insulation and high temperature strength properties coupled with their refractoriness and purity. Ceramic sealant bonding, using crystalline and vitreous sealant materials, has recently shown significant potential for joining technical ceramics to form the required shapes. Materials and techniques for joining technical ceramics including alumina, magnesia, zirconia and thoria are discussed. (orig.).
International Nuclear Information System (INIS)
The Fusion Technology task performs analyses and systems studies of conceptual fusion reactors based upon inertial and high-#beta# magnetic confinement schemes. Progress in the areas of theoretical analysis (plasma and neutral-gas blanket models), specific reactor studies (toroidal and linear theta pinches, Z pinches, laser fusion) neutronic and nuclear data assessments, materials (metals and insulators) evaluation, and general engineering design is reported.
1976-12-01
Examination of compression and resilience characteristics of fibrous insulation blankets
International Nuclear Information System (INIS)
Load-deflection characteristics of alumina and alumino-silicate fibrous blankets were experimentally determined. Load retention and springback capability of combinations of these materials were measured in a 10,000-hour test at surface temperatures of 650 to 1000"0C (1200 to 1832"0F). Experimental results are presented and future testing plans are discussed.
Engineering Assistance and sustainable development; Ingenierie conseil et developpement durable
Energy Technology Data Exchange (ETDEWEB)
Since many years, people take care of hazardous consequences of a non controlled economic growth and the sustainable development concept gains on one. This situation leads to consequences in the building industry and in the energy policy: buildings insulation in consideration, demand of consultants. In this framework, the partnership between Gaz De France and CICF has to be built. (A.L.B.)
2002-07-01
Development of MHD generator channel walls, 1
International Nuclear Information System (INIS)
Experimental results of compatibility tests on ceramics-metal bonded structures performed under high heat flux conditions in splash test apparatus are reported. Emphasis is placed on results of the channel wall design and its critical operating conditions under MHD environment. The module design of one cold type and three semihot type insulators have been tested. These materials were Al_2O_3, Al_2MgO_4, LaAlO_4, MgO and Sialon ceramics. The methods of cold type ceramics-metal bonding structure were studied on Al_2O_3 and Spinel spray coating technology. The refractory metallizing and ceramics-metal graded structure manufactured by HIP technologies were applied to bonding between the MgO or LaAlO_4 and metallic cooling system. The Sialon non-bonding structure was tested with mechanical supported cooling system by shrinc fitting method. The results indicated that the bonding structures made of the MgO(MG-S) with Copper and Fe-Ni Alloy relaxation layers and MgO(MG-NC) ...
A study was made of the timber products processing point source category, for the purpose of developing information to assist the EPA in establishing effluent limitations guidelines and standards to implement sections 301, 304, 306, and 307 of the Federal Water Pollution Control Act Amendments of 1972. The document is the result of that study.
1974-08-01
Analysis of energy demand, and evaluation of energy conservation measures in urban districts
International Nuclear Information System (INIS)
Mitsubishi Research Institute has analyzed the energy demand of a typical Japanese city, Yokohama, as well as the distribution of fossil-energy flow, and the final consumption by sectors. It has evaluated the effectiveness of various energy conservation measures, (e.g., cogeneration, electric cars, insulation,...) in countering the global warming trend. This study defines a viable methodology which may be utilized, in the future, in examining the effectiveness of environmental policies. (TEC). 1 tab., 4 figs.
A preliminary study on the dielectric constant of WPC based on some tropical woods
International Nuclear Information System (INIS)
The use of WPC as an important insulating material is studied by determining its dielectric constant. The variation of dielectric constant with moisture content is also investigated. Preliminary results show that all untreated woods studied have a higher dielectric constant than their polymer composites with the exception of Kapur and Keruing. It is therefore postulated that the presence of polymers has led to a decrease in the number of polarizable units. Such a material may be useful commercially. (author).
1986-01-01
Wax and hydrate control with electrical power
Energy Technology Data Exchange (ETDEWEB)
Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the gas/water phase may freeze solid with hydrate particles. The paper discusses ...
1997-08-01
Standardizing regulations on production of mining electrical equipment
Energy Technology Data Exchange (ETDEWEB)
The paper evaluates standardization of regulations on safety of electrical equipment for underground coal mines in the USSR. Factors increasing hazards of electrical failures of equipment in underground coal mines are analyzed: reduced lighting, increased humidity and dusts, damage caused by falling rocks or damage during haulage in underground workings, installation of electrical equipment in places easily accessible to untrained personnel. Standards on safety of electrical equipment for underground coal mining valid in the USSR are reviewed: the PIRNEh regulations on production of electrical equipment for coal mines developed by the VNIIVEh Institute, and the GOST national standards. International cooperation within the COMECON on safety of mining electrical equipment (the Interelectro Committee of the COMECON) is described. Certification of electrical equipment for coal mines is discussed on the example of electrical insulation types used in underground coal ...
1983-02-01
Quantum frustration in organic Mott insulators: from spin liquids to unconventional superconductors
We review the interplay of frustration and strong electronic correlations in quasi-two-dimensional organic charge transfer salts, such as k-(BEDT-TTF)_2X and Et_nMe_{4-n}Pn[Pd(dmit)2]2. These two forces drive a range of exotic phases including spin liquids, valence bond crystals, pseudogapped metals, and unconventional superconductivity. Of particular interest is that in several materials there is a direct transition as a function of pressure from a spin liquid Mott insulating state to a superconducting state. Experiments on these materials raise a number of profound questions about the quantum behaviour of frustrated systems, particularly the intimate connection between spin liquids and superconductivity. Insights into these questions have come from a wide range of theoretical techniques including first principles electronic structure, quantum many-body theory and quantum field theory. In this review we introduce the basic ideas of the field by discussing a simple ...
2010-01-01
Laboratory ageing of transformer oils
Energy Technology Data Exchange (ETDEWEB)
The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard ...
1996-04-01
Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications
Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
Organic electronic devices using a pentacene have improved importantly in the last several years. We fabricated pentacene organic thin-film transistors (OTFTs) with dielectric SiO{sub 2} and ferroelectric Pb(Zr{sub 0.3},Ti{sub 0.7})O{sub 3} (PZT) gate insulators. The organic devices using SiO{sub 2} and PZT films had the field-effect mobility of approximately 0.1 and 0.004 cm{sup 2}/V s, respectively. The drain current in the transfer curve of pentacene/PZT transistors showed a hysteresis behavior originated in a ferroelectric polarization switching. In order to investigate the polarization effect of PZT gate dielectrics in a logic circuit, the simple voltage inverter using SiO{sub 2} and PZT films was fabricated and measured by an output-input measurement. The gain of inverter at the poling-down state was approximately 7.2 and it was three times larger than the value measured at the poling-up state.
2007-07-16
Energy Technology Data Exchange (ETDEWEB)
The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...
1995-11-20
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for advanced PWR have been studied as follows: (1) Critical Heat Flux: Review of previous works, analysis of parametric trends, analysis of transient CHF characteristics, extension of the CHF date bank, survey and assessment of correlations, design of a intermediate-pressure CHF test loop have been performed. (2) Passive Cooling Concepts for Concrete Containment system: Review of condensation phenomena with noncondensable gases, selection of a promising concept (i.e., use of external condensers), design of test loop according to scaling laws have been accomplished. and computer programs based on the control-volume approach, and the conceptual design of test loop have been accomplished. (4) Fluidic Diode Concepts: Review of previous applications of the concept, analysis major parameters affecting the performance, development of a computational code, and conceptual investigation of the verification test loop have been performed. (5) Wet Thermal ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
In the past, organic substance is generally deemed as electrical insulator, but in recent years, molecular crystals and polymers showing electroconductivity like metal were synthesized and even those showing superconductivity have appeared. These materials are called organic metals or synthetic metals and have peculiar solid state physical properties. Examples of real application of organic electroconductive materials are becoming available, but in this article, a chip type aluminum solid electrolytic capacitor using polypyrrole is introduced. There are four kinds of capacitors including ceramic capacitors and aluminum electrolytic capacitors, etc. The aluminum electrolytic capacitor is most retarded than any other type of capacitor in introducing its chip type since its use of electrolytic solution becomes an obstacle. Polypyrrole synthesized by electrolytic polymerization through anode oxidation of pyrrole has good stability and high electroconductivity. ...
1990-07-05
Energy Technology Data Exchange (ETDEWEB)
This paper presents a method for the optimal design of high voltage transmission lines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmission line to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmission lines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design parameters, which reduce the failure rates caused by lightning, are compared with the existing design parameters of the transmission lines leading up ...
2006-04-15
Energy Technology Data Exchange (ETDEWEB)
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of inclinations (60 {<=} {beta} {<=} 90 ) of the receiver. The present 3-D numerical model is compared with other well ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
2000-01-01
Ethernet networks technology in electrical substations
Energy Technology Data Exchange (ETDEWEB)
In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent unauthorized access ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
A UPS based on a line-interactive system for CATV (Cable TV) networks has been newly developed. An inverter of the UPS featuring a pure sine wave output and equipped with an uninterrupptible transfer switch made it possible to raise its reliability high and to reduce the uninterruptible transfer time from 50 {approx} 100 ms to only 3 ms. The expected life of 15 years and maintenance-free of the UPS were realized by monitoring and optimizing the operational conditions of lead-acid batteries, aluminum electrolytic capacitors and cooling fans. The use of rust- and weather- resistant painting methods for an outer box of the UPS also contributed to extend the life of the system. (author)
1998-12-25
British Library Electronic Table of Contents (United Kingdom)
Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...
2011-01-01
A statistical evaluation of recent SSC conductors produced at IGC/ASI
International Nuclear Information System (INIS)
One of the requirements for uniform field quality in the SSC dipole magnets is the consistency in the superconducting strand characteristics from start to finish to the production phase. As full scale production of strand and cable approaches, the consistency in performance of the early batches of conductor needs to be examined. A number of 300 mm billets have been manufactured at IGC with tight process controls. The performance of the final conductor in terms of piece lengths, current density, Cu/Sc ratio and wire diameter has been evaluated. The data are analyzed in order to understand the variations that are related to the conductor design and processing. In this paper the current density of the strand is examined over the length of the billet to determine inherent variability in the Nb/Ti alloy itself.
1990-09-24
Fourier Transform Infrared (FTIR) spectroscopy has been utilized during high rate E-beam evaporation/deposition of YBa2Cu3O7 (YBCO). The results demonstrate the great utility of FTIR as an in situ monitor of YBCO deposition and processing. We detect different (amorphous/fine polycrystalline) insulating pre-existing phases to the high Tc superconducting phase which appear to have distinct reflectivity fingerprints dominated by thin film interference effects, as a function of temperature and oxygen pressure. These fingerprints reveal some of the kinetic and thermodynamic pathways during the growth of YBCO.
2007-01-01
Tubular packs Mo-AlN-Mo: long-term thermal and corrosion resistance
International Nuclear Information System (INIS)
Study results on long-term thermal and corrosion resistance of packs with electro-insulation layer of aluminium nitride are presented. Structural changes of nitride ceramics and contact zones between metal and ceramics are considered. It is shown that multilayer metallo-ceramic packs, manufactured by gas-phase technology have high electro- and thermophysical properties, high thermal and corrosion resistance relative to cesium vapor, vacuum density as well as high thermo-resistance. 8 refs., 4 figs.
Energy Technology Data Exchange (ETDEWEB)
The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.
1980-08-28
Thermal transfer augmentation by electroconvection
Energy Technology Data Exchange (ETDEWEB)
Measurements of the rate of heat transfer, enhanced by electroconvection, between two parallel plates have been carried out. Results show that the non-dimensional heat flux, or the Nusselt number, increases when an electric field acts on an injected space charge within the insulating liquid. The motion of the liquid depends on the electrical forces (Coulomb force) and the buoyancy effects have little or no influence. This is evident from steady state and time dependent results which show that for a given voltage, the Nusselt number takes the same value no matter what the flux of heat supplied to the bottom plate.
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
This invention is concerned with a solar energy system for propelling aircraft. Obtained are forces for aerodynamic lift and impetus. The lifted body had a transparent upper surface for the sun light, but black or reflecting for IR-radiation and high thermal insulation properties. Inside of the lifted body, the air temperature increases and is lifted by convection influence. The air resistance of this body is low in horizontal direction and higher in vertical position. The payload could be shifted, so that the positive or negative angle of the whole body can be selected. By this principal it is possible to transform the static lifting force in a dynamic impetus.
1981-07-30
Response of track-etch dosemeters to environmental radon
Energy Technology Data Exchange (ETDEWEB)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
1988-01-01
Prohibitions against the combustion of solid and liquid fuels in urban areas
Energy Technology Data Exchange (ETDEWEB)
Much as it is accepted for pollution control reasons air pollution abatement still is the subject of heated debates. Pollutant emissions can considerably be reduced with the help of electric power supplies. In order not to prejudice electric power users tariffs have to be adapted to the prices of other energy sources available on the market. There is a general need for energy conservation, resource conservation and the reduction of carbon dioxide emissions. Thermal insulation is among the remedial measures. Fundamental air pollution abatement measures will have to be avoiding smog warnings which are known to considerably interfere with both economic and private activities.
1988-02-01
Energy Technology Data Exchange (ETDEWEB)
A method, which estimates the lightning performance of high voltage transmission lines based on the Monte-Carlo simulation technique, is described in this paper. The average number of faults which occur in a transmission line, dividing them in single-phase and three-phase faults, as well as the average grounding resistances of the transmission lines are calculated. The method is applied, on several operating Greek transmission lines, showing good correlation between predicted and field observation results. The proposed method can be used as a useful tool in the design of electric power systems, aiding in the right insulation dimensioning of a transmission line.(author)
2003-02-01
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
British Library Electronic Table of Contents (United Kingdom)
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-01-01
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-04-01
Initial results from 50mm short SSC dipoles at Fermilab
Energy Technology Data Exchange (ETDEWEB)
Several short model SSC 50 mm bore dipoles are being built and tested at Fermilab. Mechanical design of these magnets has been determined from experience involved in the construction and testing of 40 mm dipoles. Construction experience includes coil winding, curing and measuring, coil end part design and fabrication, ground insulation, instrumentation, collaring and yoke assembly. Fabrication techniques are explained and construction problems are discussed. Similarities and differences from the 40 mm dipole tooling and management components are outlined. Test results from the first models are presented. 19 refs., 12 figs.
1991-03-01
Influence of the humidity on leakage current under accelerated aging of polymer insulating materials
Energy Technology Data Exchange (ETDEWEB)
This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.
1996-12-31
High current implantation of negative copper ions into silica glasses
Energy Technology Data Exchange (ETDEWEB)
High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.
1997-12-01
FFTF reactor immersion heaters. Revision 1
Energy Technology Data Exchange (ETDEWEB)
This specification establishes requirements for design, testing, and quality assurance for electric heaters that will be used to maintain primary Sodium temperature in the Fast Test Facility (FFTF) reactor vessel. The Test Specification (WHC-SD-FF-SDS-003) has been revised to Rev. 1. This change modifies the fabrication of approximately 25 feet of the subject heater using ceramic insulators over the heater lead wire rather than compressed magnesium oxide. Also, 304 or 316 stainless steel can be used for the heater sheath. This change should simplify fabrication and improve the heater operational reliability.
1994-08-26
Experience in use of thermal insulation compounds produced by NPP Tekhmet at Ruspolimet
British Library Electronic Table of Contents (United Kingdom)
Pilot industrial-scale testing of TSK-25 and TSK-10 compounds produced by NPP Tekhmet has been performed at Ruspolimet for siphon casting of 0.7?1.5-metric-ton ingots which are broader on the top (?flowers??) used for production of all-rolled rings; this is as an alternative to the existing process of pouring the steel into molds lubricated with petrolatum. The evaluation tests led to recommendation of the TSK-10 compound for industrial-scale testing; use of this compound enabled the petrolatum-lubricated steel casting process to be abandoned, thereby improving working conditions, and reducing rejects of the all-rolled ring products.
2009-01-01
Circuit breaker maintenance, sentinels on guard
Energy Technology Data Exchange (ETDEWEB)
Circuit breakers are essential components of every type and size of power system, and their maintenance is a matter of prime importance. This article provides a list of typical circuit breaker maintenance routines for each type of insulating medium and each type of breaker mechanism, and offers a number of useful tips to ensure the success of a circuit breaker maintenance program. It also suggests sources of information about maintenance programs for circuit breakers such as the National Electrical Testing Association's Maintenance Specifications, and companies that specialize in this type of service. 3 tabs.
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning the properties, industrial uses and federal regulation of asbestos. The references explore advantages and disadvantages associated with use of industrial robots in areas containing high concentrations of asbestos dust, the use of water as a cutting tool to control the generation of asbestos dust, and governmental policies and attitudes relative to the health and welfare of workers subjected to asbestos. Thermal insulation properties, wear characteristics, high temperature capabilities, use as a reinforcement in composite materials, and asbestos substitutes are included. (Contains a minimum of 69 citations and includes a subject term index and title list.)
1992-07-01
International Nuclear Information System (INIS)
We have investigated the growth behaviors of high temperature compatible ZrO_2 insulation coatings on Ag and AgMg sheathed Bi_2Sr_2Ca_1Cu_2O_x superconducting tapes depending on number of dipping and thermal conditions. The coatings were fabricated on long-length superconducting tape substrates using a solution derived from Zr tetrabutoxide, solvent and chelating agent for high magnetic field magnets. The layer-on-layer growth behaviors were characterized by environmental scanning electron microscope (ESEM), energy dispersive spectroscopy (EDS), X-ray maps and X-ray diffraction (XRD). This research showed that the ZrO_2 coatings were regularly grown on Ag-based tape substrates and coating thickness increased with increasing number of dipping. It was found that ceramic oxides formed at temperature range 450 and 550 deg. C. The final coating thickness changed between 6 and 8 #mu#m after annealing process. Resistance of insulation measured from ...
2004-07-15
Energy Technology Data Exchange (ETDEWEB)
To utilize solar energy effectively, a method has been developed by which daily clearness indexes can be estimated from phrase of general weather condition, and it has been examined at four places located at different typical climatic divisions in Japan. Successive results of extra-terrestrial solar insulation and measured solar insulation were illustrated at each place. It was found that the envelope of maximal value among measured values is in proportion to the extra-terrestrial solar insulation. Based on the basic clearness index and the meaning of term expressing general weather condition defined by the Meteorological Agency, the general weather condition was quantitated using the clearness index. This value was defined as weather index. Relationship between the measured clearness index at each place and the weather index was analyzed regressively. Correlation between the both was highly close, proportionally. ...
1997-07-31
PROBABILITY OF FAILURE OF THE TRUDOCK CRANE SYSTEM AT THE WASTE ISOLATION PILOT PLANT (WIPP)
Energy Technology Data Exchange (ETDEWEB)
This probabilistic analysis of WIPP TRUDOCK crane failure is based on two sources of failure data. The source for operator errors is the report by Swain and Guttman, NUREG/CR-1278-F, August 1983. The source for crane cable hook breaks was initially made by WIPP/WID-96- 2196, Rev. O by using relatively old (1970s) U.S. Navy data (NUREG-0612). However, a helpful analysis by R.K. Deremer of PLG guided the authors to values that were more realistic and more conservative, with the recommendation that the crane cable/hook failure rate should be 2.5 x 10-6 per demand. This value was adopted and used. Based on these choices a mean failure rate of 9.70 x 10-3(1/yr) was calculated. However, a mean rate by itself does not reveal the level of confidence to be associated with this number. Guidance to making confidence calculations came from the report by Swain and Guttman, who stated that failure data could be described by lognormal distributions. This is ...
2000-05-01
Mitigating aging in CANDU plants
Energy Technology Data Exchange (ETDEWEB)
Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively on station ...
1995-07-01
Continuous wave operation of an Al/sub 0.21/Ga/sub 0.31/In/sub 0.48/P /Ga/sub 0.52/In/sub 0.48/P /Al/sub 0.21/Ga/sub 0.31/In/sub 0.48/P double heterostructure (DH) laser diode was achieved for the first time at 77 K. The device was made from a DH wafer grown by atmospheric metalorganic chemical vapor deposition using triethyl metals and phosphine as source materials. At 77 K, the lasing wavelength was 0.653 ..mu..m and the threshold current was 55 mA for a diode with a nitride-insulated, 8-..mu..m-wide and 250-..mu..m-long stripe geometry.
1984-09-15
Willingness to pay for energy-saving measures in residential buildings
Energy Technology Data Exchange (ETDEWEB)
This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)
2008-03-15
Energy Technology Data Exchange (ETDEWEB)
The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.
1984-12-01
Tracking failure of gamma-ray irradiated polybutylene polymers under magnetic field
British Library Electronic Table of Contents (United Kingdom)
Polymer insulating materials used in radioactive environments are subjected to a risk of surface degradation caused by tracking. The tracking behavior becomes more complex with the presence of magnetic field. This paper presents investigation of tracking failure of gamma-ray irradiated polybutylene naphthalate (PBN) and polybutylene terephthalate (PBT) under magnetic field. The samples were irradiated in air up to 100 kGy and then up to 1000 kGy with dose rate of 10 kGy/h by using a 60Co gamma-source. Magnetic field Formula Not Shown with flux density of 250 mT was assembled perpendicularly to electric field Formula Not Shown , which gave rise to relative angle between Formula Not Shown and surface normal vector Formula Not Shown of 0degree, 90degree and 180degree, respectively. The experi...
2011-01-01
Three-dimensional laminar and turbulent natural convection cooling of heated blocks
International Nuclear Information System (INIS)
Results of three-dimensional laminar and standard K-#epsilon# turbulent numerical simulations of natural convection cooling of ten cubic aluminum blocks mounted on an insulated plate, facing a shrouding wall, are presented. This geometry is chosen so that comparison with experimental results is possible. The considered problem is of great practical importance because it simulates the case of heated electronic chips, mounted on printed board assemblies, which are frequently encountered in electronic industry applications. The problem is mathematically modeled by the three-dimensional conservation differential equations of mass, momentum, energy and turbulent kinetic energy and dissipation (for the turbulent flow model). IN this paper, these equations are numerically solved by a finite volume method and the laminar and turbulent results are compared to the experimental results obtained with similar parameters.
1990-06-18
The thermochromic properties of La{sub 1-x}Sr{sub x}MnO{sub 3} compounds
Energy Technology Data Exchange (ETDEWEB)
La{sub 1-x}Sr{sub x}MnO{sub 3} (LSMO) compounds (0.175{<=}x{<=}0.30) were prepared by conventional solid-state reaction method. Temperature dependence of the total hemispherical emittance ({epsilon}{sub H}) of the compounds from 173 to 373 K was measured on a calorimetric emissometer (CE) which was constructed based on the steady-state calorimetric method. The compounds show thermochromic properties and {epsilon}{sub H}'s have low value at low temperature and have high value at high temperature, because the compounds are dominated by metallic phase and insulator phase, respectively. We use the phase separation model to interpret the temperature dependence of {epsilon}{sub H}. (author)
2008-10-15
The feasibility of using a septic tank as a heat source for geothermal heat pumps
Energy Technology Data Exchange (ETDEWEB)
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
The thermal spike model has been successfully applied to track formation by swift heavy ions in insulators. Arguments are given supporting the assumption that the thermal spike mechanism is also valid for the anisotropic growth. The glass transition temperature is used as the main thermal parameter of the amorphous solids. Experimental results on the track formation in {alpha}-quartz and in crystalline Ni{sub 3}B and also on the anisotropic growth in Pyrex and Synsil glasses, in amorphous Pd{sub 80}Si{sub 20}, Ni{sub 3}B and Fe{sub 85}B{sub 15} are discussed. Good agreement is found with the predictions of the thermal spike model. (orig.).
1996-02-01
Cadmium telluride single crystals were grown heavily doped with chloride by the THM method. The resulting crystals were n-type with free carrier concentrations of the order of 10('12)/cm at room temperature. Hall effect studies revealed room temperature mobilities between 30 and 350 cm('2)/v-sec and resistivites between 2 x 10('3) and 10('4) ohm-cm. Studies were made of the gamma and alpha counting characteristics of these crystals with metal, metal-semiconductor, and metal-insulator electrodes. It was found that the MIS and MSS structures resulted in significant improvement over the MS structures in counting, signal-to-noise and energy resolution.
1985-01-01
International Nuclear Information System (INIS)
An overview on neutron scattering studies of ferromagnetic and antiferromagnetic all-semiconductor superlattices is presented. Diffraction experiments on MnTe/CdTe, MnTe/ZnTe and EuTe/PbTe superlattices show pronounced correlations between the MnTe and EuTe layers across the non-magnetic spaces, even though these layers are antiferromagnetic and the systems are nearly-insulating. Current theory status of these systems is discussed. Diffractometry and reflectometry data from EuS/PbS superlattices reveal pronounced antiferromagnetic coupling between the ferromagnetic EuS block. First polarized neutron reflectometry data from superlattices prepared of a novel ferromagnetic 'spintronics' material, Ga(Mn)As are also presented. (author)
2001-09-23
Structure and electric transport properties of LnSr_2FeTiO_7 (Ln = La, Nd and Gd)
International Nuclear Information System (INIS)
Three new phases with compositions, LaSr_2FeTiO_7, NdSr_2FeTiO_7 and GdSr_2FeTiO_7, were prepared by the traditional ceramic method. Lazy-Pulverix analysis of the X-ray diffraction data suggests that the phases crystallize in the RP-type (n = 2) structure in the space group, I4/mmm. The cell dimensions along the c-axis decrease with decrease in size of the rare earth ions. Electrical resistivity, as a function of temperature, shows that the materials are insulators and the resistivity decreases with decrease in the size of the rare earth ion, which is attributed to increase in the three-dimensional character. (author)
2011-02-01
Energy Technology Data Exchange (ETDEWEB)
A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.
1987-10-27
Solar energy apparatus with apertured shield
Energy Technology Data Exchange (ETDEWEB)
This paper describes in an apparatus for absorbing a beam of concentrated solar energy and which includes a cavity receiver with an inlet for transmission thereinto of solar radiation, a protective apertured shield means about the inlet. It comprises: rigid support means fixed to the periphery of the inlet and projecting radially inwardly therefrom to define a generally central aperture area through which the solar radiation can pass into the cavity receiver; and non-structural blanket means spread over the rigid support means between the periphery of the inlet and the aperture area, the material having a high temperature capability and providing for infra-red radiation insulation, while remaining relatively cool when subjected to solar radiation.
1989-07-25
Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils
Energy Technology Data Exchange (ETDEWEB)
An overview of BC Hydro`s review of its overhead transmission system to withstand earthquakes and its program of seismic upgrading, including the upgrading of tower pile foundations in liquefiable soils, was presented. BC Hydro`s system, geologic environment, seismic design criteria, investigations and analysis, treatment and alternatives and a case history of a seismic upgrade of a tall river crossing tower at the Pitt River in the Lower Mainland of B.C. were summarized. It was concluded that the inherent strength of towers, conductors, fittings and insulators was sufficient to withstand earthquakes. The towers most susceptible to slope and soil failure due to seismic activity were tall river crossing towers. It was suggested that soils investigations, seismicity, ground response, liquefaction and stability analyses be carried out at each site. The results of these tests would help to establish system seismic design criteria at each location. 11 refs., 9 figs.
1995-12-31
Science of quantum phase transitions and quantum criticalities
International Nuclear Information System (INIS)
Apart from conventional phase transitions driven by the thermal effects, quantum phase transitions generated by quantum fluctuations have their own mechanisms that are reflected in critical phenomena. Quantum phase transitions have an origin from spontaneous symmetry breaking commonly to thermal phase transitions. Even in this case, inherent quantum fluctuations substantially modify and yield new aspects. Quantum phase transitions have, however, another mechanism caused by topology changes, which gives completely new characters. Recently, a mechanism which connects these two has been found. Proimities from first-order transitions and phase separatins as well as from multiphase coexistence also generate characteristic and unconventional quantum criticalities. Understanding novel quantum criticalities offers a firm basis of recent active researches on fields such as magnetism, ferroelectricity and metal-insulator transitions with potential applications and functional ...
2011-02-01
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to ...
2007-07-01
Realization of good indoor climate in low-energy office
Energy Technology Data Exchange (ETDEWEB)
Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)
1994-12-31
Radiation hardening of integrated circuits technologies
International Nuclear Information System (INIS)
The radiation hardening studies started in the mid decade 1960-1970. To survive the different military or space radiative environment, a new engineering science was born, to understand the degradation of electronics components. The different solutions to improve the electronic behavior in such environments have been named 'radiation hardening' of the technologies. Improvement of existing technologies, and qualification methods have been widely studied. However, on the other hand, specific technologies were developed: the Silicon On Insulator technologies for CMOS or Bipolar. The HSOI3HD technology offers today the highest hardening level for the integration density of hundreds of thousand transistors on the same silicon. Full complex systems could be produced on a single die with a technological radiation hardening and no more system hardening.
Energy Technology Data Exchange (ETDEWEB)
Preliminary studies were preformed to determine whether thermal conductivity of cementitious grouts used to backfill heat exchanger loops for geothermal heat pumps could be improved, thus improving efficiency. Grouts containing selected additives were compares with conventional bentonite and cement grouts. Significant enhancement of grout alumina grit, steel fibers, and silicon carbide increased the thermal conductivity when compared to unfilled, high solids bentonite grouts and conventional cement grouts. Furthermore, the developed grouts retained high thermal conductivity in the dry state, where as conventional bentonite and cement grouts tend to act as insulators if moisture is lost. The cementitious grouts studied can be mixed and placed using conventional grouting equipment.
1996-06-01
Practical superconductor development for electrical power applications
Energy Technology Data Exchange (ETDEWEB)
Development of useful high-critical-temperature (high-{Tc}) superconductors requires synthesis of superconducting compounds; fabrication of wires, tapes, and films from these compounds; production of composite structures that incorporate stabilizers or insulators; and design and testing of efficient components. This report describes technical progress of research and development efforts aimed at producing superconducting components based on the Y-Ba-Cu, Bi-Sr-Ca-Cu, Bi-Pb-Sr-Ca-Cu, and Tl-Ba-Ca-Cu oxides systems. Topics discussed are synthesis and heat treatment of high-{Tc} superconductors, formation of monolithic and composite wires and tapes, superconductor/metal connectors, characterization of structures and superconducting and mechanical properties, and fabrication and properties of thin films. Collaborations with industry and academia are also documented. 10 figs.
1991-10-01
Pencil-like mm-size electron beams produced with linear inductive voltage adders
International Nuclear Information System (INIS)
We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.
Passive solar design handbooks: Vol III: passive solar design analysis and supplement
Energy Technology Data Exchange (ETDEWEB)
This book applies the Los Alamos Solar Load Ratio (SLR) method to the design of passive solar heating systems, with an emphasis on the average annual heating energy consumption. Recommendations are given on minimizing heating energy consumption by appropriate choices of conservation level and solar system parameters. Analytical methods and supporting tables are presented which enable simple, fast estimates of the heating energy consumption as part of the design process. Topics considered include SLR correlations, the load collector ratio (LCR) method, sensitivity data, cooling considerations, conservation formulas, design procedure, life-cycle costs, high-mass direct gain buildings, low-mass sun-tempered buildings, sunspaces, off-reference night insulation, correlation equations, and mixed systems.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)
2008-01-15
Near-edge structures from first principles all-electron Bethe-Salpeter equation calculations
International Nuclear Information System (INIS)
We obtain x-ray absorption near-edge structures (XANES) by solving the equation of motion for the two-particle Green's function for the electron-hole pair, the Bethe-Salpeter equation (BSE), within the all-electron full-potential linearized augmented plane wave method (FPLAPW). The excited states are calculated for the Li K-edge in the insulating solids LiF, Li_2O and Li_2S, and absorption spectra are compared with independent particle results using the random phase approximation (RPA), as well as supercell calculations using the core-hole approximation within density functional theory (DFT). The binding energies of strongly bound excitations are determined in the materials, and core-exciton wavefunctions are demonstrated for LiF.
2009-03-11
Natural convection cooling of the IFMIF target and test cell
International Nuclear Information System (INIS)
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
2007-10-01
Mineral-wool industry: opportunities for natural gas technologies. Topical report, January-July 1987
To quantify the opportunities for natural gas and identify technological advances needed to capture such opportunities, the mineral-wool industry was analyzed with respect to the principal companies, their capabilities, and markets. The mineral-wool industry is stable with a slightly declining market. Of its market segments, only commercial acoustic insulation (which is currently dominant) is likely to be affected by growth in the next ten years. The principal process is based on treatment of blast-furnace slags in a cupola furnace using coke as the fuel and reducing agent. Expanded use of gas, as a substitute for coke, would eliminate environmental problems and expand the latitude of suitable raw materials. The study provides insights into the mineral-wool industry and identifies factors that may constitute bases for future usage of natural gas.
1988-05-01
Magnetic properties of Ab initio model of iron-based superconductors LaFeAsO
International Nuclear Information System (INIS)
By using a variational Monte Carlo method, we examine an effective low-energy model for LaFeAsO derived from an ab initio downfolding scheme. We show that quantum and many-body fluctuations near the antiferromagnetic (AF) quantum critical point largely reduce the antiferromagnetic ordered moment. Our derived model not only quantitatively reproduces the small ordered moment in LaFeAsO, but also accounts for the diversity from LaFePO, BaFe_2As_2 to FeTe. Electron correlation is found to determine the observed material dependence. We also find that LaFeAsO is subject to large orbital fluctuations, sandwiched by the AF Mott insulator and weakly correlated metals. The orbital fluctuations and Dirac-cone dispersion hold keys for the diverse magnetic properties. (author)
2011-02-01
Ion implantation into concave polymer surface
Energy Technology Data Exchange (ETDEWEB)
A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows that gas-barrier property enhances due to the modification.
2006-01-15
Ion beam induced charge imaging of epitaxial GaN detectors
Energy Technology Data Exchange (ETDEWEB)
We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.
2004-09-21
Interactions at the cofired interface of Ag/Pd electrode and lead-based ferroelectrics
Energy Technology Data Exchange (ETDEWEB)
In the present study, element interdiffusions at the cofired interface of 9/1 Ag/Pd electrode and lead magnesium niobate (PMN)-based ferroelectrics were investigated using Auger Electron Spectroscopy (AES). Intense interdiffusions at the interface were observed while Ag and Pd could penetrate into the ceramics for about 1 {mu}m. Ag-doping experiments were carried out to further study the effects of Ag diffusion on electrical properties of the ceramics. The results showed that Ag could be incorporated into solid solution of the ceramics as Ag{sup +}. As a whole, the Curie temperature (Tc) and dielectric constant of the ceramics decreased with Ag addition. However, Ag addition had no obvious effect on the insulation resistivity. The results inferred that Ag{sup +} could substitute for Pb{sup 2+} at A site of ABO{sub 3} lattice, thereby oxygen vacancies were generated.
2003-05-25
Energy Technology Data Exchange (ETDEWEB)
Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)
1980-11-01
High voltage transmission lines studies with the use of artificial intelligence
Energy Technology Data Exchange (ETDEWEB)
The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of electric engineers. (author)
2009-12-15
Fractional domain walls from on-site softening in dipolar bosons
We study dipolar bosons in a 1D optical lattice and identify a region in parameter space---strong coupling but relatively weak on-site repulsion---hosting a series of stable CDW states whose low-energy excitations, built from "fractional domain walls", are remarkably similar to those of non-abelian fractional quantum Hall states. Here, a conventional domain wall between translated CDW's may split by inserting strings of degenerate, but inequivalent, CDW states. Outside these insulating regions, we find numerous supersolids as well as a superfluid regime. The mentioned phases should be accessible experimentally, and in particular, the fractional domain walls can be created in the ground state using single-site addressing, i.e. by locally changing the chemical potential.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The kinetics of the electropolymerization of 3-amino-1,2,4-triazole on a brass substrate in alkaline solution containing methanol was investigated using cyclic polarization, chronoamperometry, electrochemical impedance techniques and scanning electronic microscopy. The polymeric film was prepared by successive cycles of potential of a 60Cu-Zn electrode between 0 and 1.6 V. During the second cycle, the oxidation peak of the monomer disappears indicating the formation of the insulating film. We have also shown that the monomer oxidation reaction is essentially irreversible and controlled by a diffusion process. The protective effect of the film formed on brass has been studied in a 3%NaCl and 3%NaCl + S{sup 2-} solution. The results showed important inhibition efficiency, about 96% for 4 h of testing time.
2008-06-15
British Library Electronic Table of Contents (United Kingdom)
The kinetics of the electropolymerization of 3-amino-1,2,4-triazole on a brass substrate in alkaline solution containing methanol was investigated using cyclic polarization, chronoamperometry, electrochemical impedance techniques and scanning electronic microscopy. The polymeric film was prepared by successive cycles of potential of a 60Cu-Zn electrode between 0 and 1.6V. During the second cycle, the oxidation peak of the monomer disappears indicating the formation of the insulating film. We have also shown that the monomer oxidation reaction is essentially irreversible and controlled by a diffusion process. The protective effect of the film formed on brass has been studied in a 3%NaCl and 3%NaCl+S2- solution. The results showed important inhibition efficiency, about 96% for 4h of testing ...
2008-01-01
Electrical properties of a calix[4]acid/amine Langmuir-Blodgett thin film
British Library Electronic Table of Contents (United Kingdom)
In this work the DC and AC characteristics for metal-LB film-metal structures deposited by a standard Langmuir-Blodgett film deposition technique are investigated. The conduction mechanism has been studied for a thin film structure in which a calix[4]arene substituted with carboxylic acid groups has been deposited alternately with a calix[4]arene molecule substituted with amine groups. This LB film structure shows a typical insulating behaviour for low voltage values and the Schottky effect becomes dominant when the voltage increases. The conductivity at low voltage values was found to be 1.34x10^-^1^3Scm^-^1. The height of the potential barrier was determined to be 1.65eV for this alternate layer LB film system.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Stoichiometric MgAl{sub 2}O{sub 4} spinel specimens irradiated in FFTF-MOTA at temperatures between 385 and 750C to fluences ranging from 2.2 to 24.9 {times} 10{sup 22}n cm{sup {minus}2} (E>0.1 MeV) darken significantly, but do not develop any significant loss in weight or change in dimensions. Similar behavior was observed in both single crystal and fully dense polycrystalline specimens. Measurements of elastic constants by an ultrasonic technique show that no measurable changes occur as a result of the irradiation. These and other results confirm the stability of this material for fusion application as an electrical insulator.
1993-10-01
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Development of nanocomposite polymer materials for electrical and electronic applications
International Nuclear Information System (INIS)
Some results and experimental procedures of laboratory are reported in the frame of researches conducted for the development of new nanostructured composite materials. These new materials, which are constituted by an organic phase: the polymer and an inorganic phase: the silicate, are being strongly investigated nowadays so it is expected that they could provide, among other, better electrical insulation properties and flame-delay in electrical and electronic applications. The laboratory experimental work has been developed from two families of polymers, thermoplastics and thermosets and clays silicates providing lamellar type. There are now some preliminary results, such as obtaining thin films of these nanocomposite materials, their complete characterization by X-ray diffraction, scanning microscopy and thermogravimetric analysis, they do well to wait for future research activities. (author)
2007-01-01
Development of a greenhouse-type solar dryer for medicinal plants and herbs
Energy Technology Data Exchange (ETDEWEB)
The economy of medicinal plant production is burdened considerably by the energy costs of drying. To substitute fossil energy, a solar heated dryer was developed, taking a plastic film greenhouse as superstructure to lower the initial costs. The solar air heaters, being incorporated into the roof, consist of a black absorber tissue, which is placed between the transparent cover of the greenhouse and an insulating air-bubble foil. To obtain a modular design, the system is structured along the ridge into segments of 2 m width. Each segment forms an independent solar air heater/batch dryer unit and is operated by a fan with a power consumption of 500 W. A prototype was tested in Yugoslavia, drying mint, sage and hops. (author).
1989-01-01
Calorimetric sensors for energy deposition measurements
Energy Technology Data Exchange (ETDEWEB)
A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.
1998-12-31
CFD analysis and overheating control of a turbine
Energy Technology Data Exchange (ETDEWEB)
The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the installation of external fins on the stack shell. ...
2004-11-01
Bulk and surface electronic structure of hexagonal boron nitride
International Nuclear Information System (INIS)
Accurate full-potential self-consistent linearized augmented-plane-wave (FLAPW) calculations have been carried out for hexagonal boron nitride. The resulting energy-band structure indicates that this material is an indirect-gap insulator and shows the existence of two unoccupied interlayer bands, similar to those found in graphite and graphite intercalation compounds. Chemical bonding is mainly covalent, with a small charge transfer towards the nitrogen atoms. Moreover, model-potential calculations, based on first-principles FLAPW wave functions and potentials, have been used to study slabs of thickness up to 35 layers. Contrary to the case of graphite, our results do not provide evidence of surface states associated with the interlayer bands.
Boron diffusion in amorphous silicon
Energy Technology Data Exchange (ETDEWEB)
We have investigated B diffusion in pre-amorphized silicon. In our experiments, the crystalline surface layer of silicon-on-insulator (SOI) substrates was completely amorphized by Ge ion implantation. Using SOI substrates in this fashion suppressed solid-phase-epitaxy regrowth, making it possible to investigate B diffusion in pre-amorphous silicon over a wider range of temperatures (500-650 deg. C) and times (5-1000 s) than has previously been reported. Diffusivities were determined with the aid of computational processes modeling. The results from this work demonstrate the B diffusion in a-Si is concentration dependent, exhibits a transient enhanced diffusion, and possesses an Arhennius behavior with activation energy of {approx}2.1 eV.
2005-12-05
Boron diffusion in amorphous silicon
International Nuclear Information System (INIS)
We have investigated B diffusion in pre-amorphized silicon. In our experiments, the crystalline surface layer of silicon-on-insulator (SOI) substrates was completely amorphized by Ge ion implantation. Using SOI substrates in this fashion suppressed solid-phase-epitaxy regrowth, making it possible to investigate B diffusion in pre-amorphous silicon over a wider range of temperatures (500-650 deg. C) and times (5-1000 s) than has previously been reported. Diffusivities were determined with the aid of computational processes modeling. The results from this work demonstrate the B diffusion in a-Si is concentration dependent, exhibits a transient enhanced diffusion, and possesses an Arhennius behavior with activation energy of #approx#2.1 eV.
2005-12-05
Automated three-dimensional X-ray analysis using a dual-beam FIB
International Nuclear Information System (INIS)
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
Industrial premises bear more and more important thermal constraints which can commonly reach 150 W/m{sup 2} and more. The reason is the general development of automation and automatic devices and the better thermal insulation of buildings. Production quality requires also more and more strict ambient conditions (temperature, humidity, air quality, air flow etc..). Thus, the air-conditioning market in the industrial sector is more linked to economic factors such as productivity and profit than to thermal comfort of workers. However, the air-conditioning potentialities in the industrial sector remains under-exploited in France. This paper analyzes the reasons of this situation in terms of investments and equipments. (J.S.)
1997-09-01
A superconductor to superfluid phase transition in liquid metallic hydrogen
Although hydrogen is the simplest of atoms, it does not form the simplest of solids or liquids. Quantum effects in these phases are considerable (a consequence of the light proton mass) and they have a demonstrable and often puzzling influence on many physical properties, including spatial order. To date, the structure of dense hydrogen remains experimentally elusive. Recent studies of the melting curve of hydrogen indicate that at high (but experimentally accessible) pressures, compressed hydrogen will adopt a liquid state, even at low temperatures. In reaching this phase, hydrogen is also projected to pass through an insulator-to-metal transition. This raises the possibility of new state of matter: a near ground-state liquid metal, and its ordered states in the quantum domain. Ordered quantum fluids are traditionally categorized as superconductors or superfluids; these respective systems feature dissipationless electrical currents or mass flow. Here we report an ...
2004-01-01
X-radiation effects on muscle cell membrane electrical parameters
International Nuclear Information System (INIS)
Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...
Substance Flow Analyses of Organic Pollutants in Stockholm
International Nuclear Information System (INIS)
This paper summarizes substance flow analyses for four organic substances in the City of Stockholm, Sweden: diethylhexyl phthalate (DEHP), alkylphenolethoxylates (APEO), polybrominated diphenylethers (PBDE) and chlorinated paraffins (CP). The results indicate that the stocks of APEO, PBDE and CP all are approximately 200-250 tonnes, whereas the DEHP stock is two orders of magnitude larger. Emissions can be linked to imported consumer goods such as electronics (PBDE) and textiles (APEO), and to construction materials (DEHP, CP). For several of the substances considerable amounts remain in the technosphere for a long time, even after use of the substance in new products has been eliminated. For example, the use of DEHP as plasticizer for PVC plastics in cables and floorings has more or less been phased-out, but still these applications make up a stock of some 20,000 tonnes (85% of the total DEHP stock in Stockholm) and emit 28 tonnes of DEHP annually (93% of overall ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, water cut-off performance, chemical resistance, and shape retention performance against ...
1991-03-25
Splice assembly tool and method of splicing
Energy Technology Data Exchange (ETDEWEB)
A splice assembly tool for assembling component parts of an electrical conductor while producing a splice connection between electrical cables therewith, comprises a first structural member adaptable for supporting force applying means thereon, said force applying means enabling a rotary force applied manually thereto to be converted to a longitudinal force for subsequent application against a first component part of said electrical connection, a second structural member adaptable for engaging a second component part in a manner to assist said first structural member in assembling the component parts relative to one another and transmission means for conveying said longitudinal force between said first and said second structural members, said first and said second structural members being coupled to one another by said transmission means, wherein at least one of said component parts comprises a tubular elastomeric sleeve and said force applying means provides a ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts ...
2002-01-01
International Nuclear Information System (INIS)
Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. 2. We could detected, as anticipated, a defect (outer circumferential wall thinning defect, 20% depth) on ...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am 21. Juli 1998 ...
1998-11-30
Open vs Closed Access Femtocells in the Uplink
Femtocells are assuming an increasingly important role in the coverage and capacity of cellular networks. In contrast to existing cellular systems, femtocells are end-user deployed and controlled, randomly located, and rely on third party backhaul (e.g. DSL or cable modem). Femtocells can be configured to be either open access or closed access. Open access allows an arbitrary nearby cellular user to use the femtocell, whereas closed access restricts the use of the femtocell to users explicitly approved by the owner. Seemingly, the network operator would prefer an open access deployment since this provides an inexpensive way to expand their network capabilities, whereas the femtocell owner would prefer closed access, in order to keep the femtocell's capacity and backhaul to himself. We show mathematically and through simulations that the reality is more complicated for both parties, and that the best approach depends heavily on whether the multiple access scheme is ...
2010-01-01
On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir
Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the ...
1992-01-01
Limitations of traveling wave relaying for overhead EHV transmission lines
Energy Technology Data Exchange (ETDEWEB)
Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and frequency domain methods. This time-domain method offers more ...
1986-01-01
Lead recycling; Namari no recycle
Energy Technology Data Exchange (ETDEWEB)
In Japan, lead has been widely used for gasoline additives, inorganic chemicals such as pigment, lead pipes/plates, and coating materials of cable. Because of the steady increase in car population and the mounting of environmental concern, lead consumption ratio for lead-acid batteries is tending to increase gradually up to 70% with decreasing the consumption for gasoline additives. This paper describes the recycling of lead-acid batteries in Japan. Since the latter half of FY 1994, the battery manufacturing industry started the new lead recycling system. The recycling ratio of the used lead-acid batteries became 90% in 1996 from 84% in 1994. In near future, it can reach to 95%, the recycling ratio in some European countries. The primary smelting occupies 53%, and the secondary smelting occupies 47%. For the conventional method by secondary smelting makers, reduction smelting and copper removing of lead electrodes are conducted, and lead is recycled as tertiary ...
1997-12-25
Integration of turbo-generator modules in digital transient network analyzer
The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the Digital TNA depends on: (a) the theoretical method of Decoupled ...
1994-05-01
Electroforming of metals: state-of-the-art assessment. Final report
Energy Technology Data Exchange (ETDEWEB)
An assessment of the state-of-the-art of electromagnetic and electrohydraulic forming of metal parts has been conducted. Electromagnetic forming (EMF) shapes parts by a force resulting from a high-density magnetic field. The electrohydraulic forming (EHF) process differs in that the force is applied to parts from a shock wave emanating from a point within a fluid medium. Both processes are used to form relatively thin-section hollow or flat products. This survey has found that, of the two electrotechnologies, the electromagnetic forming process is expected to be used increasingly in a broad range of industries, particularly for automotive, aircraft, and electrical-cable components. In contrast, the level of applications for the electrohydraulic forming method is expected to remain essentially unchanged over the near- and long-term period. This is because its use is restricted to relatively unusual part shapes in industries that do not require large unit quantities. ...
1986-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level in few points of ...
2007-05-10
Energy Technology Data Exchange (ETDEWEB)
The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system components are commercially available; some have been modified at LASL for DYMAC purposes; others were designed and fabricated at LASL. This manual provides circuit diagrams ...
1980-01-01
Vacuum arc ignition by penning discharge in a strong magnetic field
Energy Technology Data Exchange (ETDEWEB)
Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc applications it is impermissible because it leads to the ...
1995-12-31
Use of polymer conductors for welding thermoplastic materials
International Nuclear Information System (INIS)
Although some polymer conductors of electricity (ex. Polyanilines) are materials known for more than 100 years, only recently have the interesting chemical, electrical and optic properties of their insulating and conducting forms been recognized. Advances made in the chemistry of polymer conductors have also led to improvements in processing them. This work studies a practical application of these materials: the use of polymer conductors for the remote welding of insulating thermoplastic polymers, using energy from microwaves for the local heating of the union. Many thermoplastics (for ex. Polyethylene) do not absorb, or absorb very little, energy from microwaves. Different conductor materials (conductor polymers, carbon nanotubes), however, heavily absorb energy from microwaves with the resulting heating. In this way the welding zone can be heated without affecting the rest of the piece. Conductor polymers (polyanilines) were synthesized ...
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
Many industrial workshops in Germany were erected during the 40s and 50s, especially at the beginning of the economic boom. After more than 40 years, these facilities are in need of structural and production-technical modernization. A case in point is the carriage fabrication workshop of the Salzgitter-based company Linke-Hoffmann-Busch. The characteristic features of this type of building are large glazed areas, free uncontrolled ventilation and substantial height. Opportunities for energy-oriented and light-technical modernization are demonstrated at this Salzgitter workshop in exemplary form, the emphasis being on the use of solar energy components and, particularly, transparent thermal insulation. (orig.) [Deutsch] In der Bundesrepublik Deutschland gibt es viele Produktionshallen, die in den vierziger und fuenfziger Jahren, insbesondere zu Beginn des wirtschaftlichen Aufschwungs, errichtet wurden. Diese Hallen sind nach ueber vierzig Jahren sowohl aus baulichen ...
1997-12-31
Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study
Energy Technology Data Exchange (ETDEWEB)
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...
2003-06-01
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into consideration the thermal-hydraulics and the engineering requirements to define the shield configuration. A careful integration was ...
1989-10-01
Energy Technology Data Exchange (ETDEWEB)
Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored which provided a high ...
1983-12-15
Quasiparticle band structure of thirteen semiconductors and insulators
By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al{sub 0.5}Ga{sub 0.5}As and In{sub 0.53}Ga{sub 0.47}As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, {ital E}({Gamma}{sub 1{ital c}}) of AlP, {ital E}({ital L}{sub 1{ital c}}) of AlAs, and {ital E}({ital L}{sub 1{ital c}}) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are ...
1991-06-15
Quasiparticle band structure of thirteen semiconductors and insulators
International Nuclear Information System (INIS)
By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al_0_._5Ga_0_._5As and In_0_._5_3Ga_0_._4_7As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, E(#GAMMA#_1_c) of AlP, E(L_1_c) of AlAs, and E(L_1_c) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are also examined in this work. The many-body corrections to the eigenvalues of ...
Energy Technology Data Exchange (ETDEWEB)
More than two and a half years of monitoring of a passive house school and day-care centre in Frankfurt a. M. show comfortable indoor climate and good air quality. The space heat consumption is low and shows savings of approximately 90 % as compared to average existing schools. Excellent performance was also achieved in terms of primary energy. The results of further analyses of the efficient ventilation system with heat recovery, the perimeter insulation as an alternative to floor slab insulation and the influence of the air change due to the entrance door are presented. (Abstract Copyright [2008], Wiley Periodicals, Inc.) [German] Ueber zweieinhalb Jahre Monitoring einer Passivhaus-Schule und Kindertagesstaette (KiTa) in Frankfurt a.M. zeigt behagliche raumklimatische Bedingungen bei guten Luftqualitaeten. Die Heizwaermeverbrauchswerte liegen wie erwartet niedrig und zeigen Einsparungen um 90 % gegenueber dem Durchschnitt im Bestand. Auch ...
2008-02-15
High-pressure gas quenching in cold chambers for increased cooling capacity
Energy Technology Data Exchange (ETDEWEB)
Gas quenching for the hardening of steel parts is a lower-pollution alternative to quenching in quenchants such as oil or salt. As the surfaces of the cooled parts remain clean after gas quenching, there is no need to wash them after heat treatment, which reduces the consumption of oils and detergents. The fire risk and ventilation requirements of oil quenching are eliminated. In addition, some trials have shown that gas quenching has a positive effect on distortion, representing a saving in finishing work and thus a reduction in costs. Today, gas quenching is used almost solely in vacuum furnaces. Quenching is normally performed in the same chamber as heating, which means that besides quenching the batch, the quenching system must also remove heat from the heating elements and insulation of the furnace. Previous trials performed by IVF have shown that gas quenching with helium of ball bearing and carburizing steels (and other steels) in sizes up to 25 mm at ...
1996-12-31
Evaluation of cathodic dis-bonding of three types of coatings by DC and AC methods
Energy Technology Data Exchange (ETDEWEB)
For the protection of buried steel pipeline, it is common practice to coat the pipelines with highly insulating coating and apply a cathodic current to insulate the pipe from the aggressive environment. Cathodic current protects holidays or damaged area of coating which required less current than would be needed for an uncoated pipe, but because of the cathodic reactions evolution will be taken H{sub 2} and OH{sup -} on holidays which exposed metal to the environment place. This effect is to cause loss bond of coating around the holidays called cathodic dis-bonding. In this paper we measured cathodic dis-bonding of three types of coatings at - 1.5 V(Cu/CuSO{sub 4}) according to ASTM G8. We studied on cathodic dis-bonding resistance of petroleum-base, coal tar-base and polyethylene plastic tape coatings. After 30 days immersion in electrolyte it was found that the cathodic disbanding resistance of polyethylene plastic tape coating is lower than ...
2004-07-01
International Nuclear Information System (INIS)
Plasma immersion ion implantation (PIII) is an effective materials modification and synthesis technique but has seldom been applied to ceramic materials due to the high electrical resistance that reduces the ion bombardment energy and sometimes causes serious electrical arcing in the instrument. Even in cases where PIII is applicable, the surface properties of the implanted insulating materials can be seriously affected due to the low ion energy and materials damage from electrical arcing. In order to enhance the surface and mechanical properties such as wear resistance of ceramic materials used in many industrial applications, surface modification is needed. In this work, we conduct carbon implantation into sintered #alpha#-SiC (silicon carbides that are widely used in vacuum ceramic bearings) using mesh-assisted plasma immersion ion implantation to enhance the surface properties. The use of a conducting grid is necessitated by the high electrical resistance that ...
2004-03-01
Development of a Commercial Process for the Production of Silicon Carbide Fibrils
Energy Technology Data Exchange (ETDEWEB)
The current work continues a project completed in 1999 by ReMaxCo Technologies in which a novel, microwave based, VLS Silicon Carbide Fibrils concept was verified. This project continues the process development of a pilot scale commercial reactor. Success will lead to sufficient quantities of fibrils to expand work by ORNL and others on heat exchanger tube development. A semicontinuous, microwave heated, vacuum reactor was designed, fabricated and tested in these experiments. Cylindrical aluminum oxide reaction boats are coated, on the inner surface, with a catalyst and placed into the reactor under a light vacuum. A series of reaction boats are then moved, one at a time, through the reactor. Each boat is first preheated with resistance heaters to 850 C to 900 C. Each reaction boat is then moved, in turn, to the microwave heated section. The catalyst is heated to the required temperature of 1200 C to 1300 C while a mixture of MTS (methyl trichlorosilane) and hydrogen are introduced ...
2003-04-22
A study of passive and inherent safety design concepts for advanced light= water reactors
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of condensation heat transfer and effect of non-condensable gases) on the condensation phenomena, design and ...
1997-07-01
A bistable snapping microactuator and its mechanical analysis
Energy Technology Data Exchange (ETDEWEB)
A bistable, micromechanical switching device and its buckling stability, heat transfer, and dynamics analyses are summarized. A SEM picture of the device. The buckling element of the microactuator is a U-shaped cantilever ({open_quotes}buckled cantilever{close_quotes} in the picture) consisting of two 0.8 micron-thick polysilicon layers with 0.5 micron-thick oxide insulator sandwiched between them. The 82 micron-long cantilever is buckled by the {open_quotes}tension band{close_quotes} made of 0.5 micron-thick silicon nitride. The snapping action of the microactuator to the down-state (or up-state) is achieved by heating the upper (or lower) polysilicon layer of the buckling cantilever with electric current. Analysis of a snapping action between two buckled states is described. It provides a design framework as well as operation guidelines for the actuator. The buckling stability criterion and the deflection of the buckled cantilever are discussed by using a ...
1995-12-31
TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR
Energy Technology Data Exchange (ETDEWEB)
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof ...
2010-03-01
Energy Technology Data Exchange (ETDEWEB)
Yellow-emitting pulsed laser operation of an Al/sub 0.37/Ga/sub 0.15/In/sub 0.48/P/Al/sub 0.16/Ga/sub 0.36/In/sub 0.48/P/ Al/sub 0.37/Ga/sub 0.15/In/sub 0.48/P double heterostructure laser diode was obtained at 77 K. The emission wavelength was 579 nm. The threshold current density was 5.6 kA/cm/sup 2/ for a diode with a Si/sub 3/N/sub 4/ insulated 8-..mu..m-wide and 250-..mu..m-long stripe geometry. The device was made from a DH wafer grown by conventional metalorganic chemical vapor deposition using triethyl metals and phosphine as source materials.
1984-11-01
Turning the Moon into a Solar Photovoltaic Paradise
Lunar resource utilization has focused principally on the extraction of oxygen from the lunar regolith. A number of schemes have been proposed for oxygen extraction from Ilmenite and Anorthite. Serendipitously, these schemes have as their by-products (or more directly as their "waste products"), materials needed for the fabrication of thin film silicon solar cells. Thus lunar surface possesses both the elemental components needed for the fabrication of silicon solar cells and a vacuum environment that allows for vacuum deposition of thin film solar cells directly on the surface of the Moon without the need for vacuum chambers. In support of the US space exploration initiative a new architecture for the production of thin film solar cells on directly on the lunar surface is proposed. The paper discusses experimental data on the fabrication and properties of lunar glass substrates, evaporated lunar regolith thin films (anti-reflect coatings and insulators), and ...
2006-01-01
The coil of the MBI bending magnets for the LHC injection transfer lines
All MBI bending magnets in each of the two LHC injection transfer lines will be powered in series. The limited output voltage of existing power converters lead to an unusual coil design avoiding external return bus-bars by combining two overlapping half-coils, electrically separated, with 3 1/2 turns each in a monolithic structure. The voltage between turns in one coil can reach up-to 3.6 kV. The coil has been designed with particular care for obtaining high interturn and ground insulation. Flux-free soldering of connections with plug-in cone sleeves is applied, allowing to execute water cooled current connections as prolongation of the coil conductor. Epoxy compound polymerization in the impregnation mould is obtained by passing overheated water in regulated cycles through the water circuit of the coil conductor. We describe the design basics as well as various test results of pre-series and series produced coils. (4 refs).
2002-01-01
Synchrotron PES and NEXAFS studies of self-assembled aromatic thiol monolayers on Au(1 1 1)
Energy Technology Data Exchange (ETDEWEB)
Self-assembled monolayers (SAMs) on various metal, semiconductor or insulator substrates can be easily modified with specific functional groups of interest and have promising applications in surface wetting (hydrophobic/hydrophilic modification), tribology, corrosion protection, sensor electrodes modification, molecular and biomolecular recognition, protein adsorption, cell adhesion, and molecular- or organic-electronic device fabrications. In this paper, we highlight recent progress in the development of SAMs on solid substrates as well as their practical applications, with particular emphasis on the characterization of self-assembled aromatic thiol monolayers with different functional groups on Au(1 1 1) using synchrotron-based photoemission spectroscopy and near-edge X-ray absorption fine structure measurements. The SAM-related molecular orientation, electronic structures, and chemical bonding are presented. Using copper(II) phthalocyanine as a model system, we ...
2009-05-15
Energy Technology Data Exchange (ETDEWEB)
The aim of this thesis is to study the coherent transport in semiconducting-superconducting junctions. The SnPb-GaAs system has been studied. It has been shown that the behaviour of this junction is controlled by the disordered area induced by the annealing of the connection near the interface. For a few resistant junction, a conductance anomaly under the gap has been observed and has been explained by a mesoscopic effect in the limit of the very high disorders. The conductance of more resistant junctions has only been bound to the properties of the very disordered area of the semiconductor. The part of the electron-electron interactions on the phase coherence length and on the conductance has been studied. The evolving of the correction of the conductance due to interactions in magnetic field has been followed. The effect of the spin degeneration suppression in CdTe and the GaAs sign inversion in Shubnikov de Haas oscillations rate has been observed. At last has been studied the ...
1997-11-07
The strain dependence of Si-Ge interdiffusion in epitaxial Si/Si{sub 1-y}Ge{sub y}/Si heterostructures on relaxed Si{sub 1-x}Ge{sub x} substrates has been studied using secondary ion mass spectrometry, Raman spectroscopy, and simulations. At 800 and 880 deg. C, significantly enhanced Si-Ge interdiffusion is observed in Si/Si{sub 1-y}Ge{sub y}/Si heterostructures (y=0.56, 0.45, and 0.3) with Si{sub 1-y}Ge{sub y} layers under compressive strain of -1%, compared to those under no strain. In contrast, tensile strain of 1% in Si{sub 0.70}Ge{sub 0.30} layer has no observable effect on interdiffusion in Si/Si{sub 0.70}Ge{sub 0.30}/Si heterostructures. These results are relevant to the device and process design of high mobility dual channel and heterostructure-on-insulator metal oxide semiconductor field effect transistors.
2006-01-02
Spark decomposition of SF/sub 6/
Energy Technology Data Exchange (ETDEWEB)
Gas-insulated systems employing SF/sub 6/ are utilized in a variety of applications in power delivery systems. Because electric arcs, sparks or corona can decompose SF/sub 6/ into by-products having chemical properties different from SF/sub 6/, environmental concerns arise regarding inadvertent human exposures to electrically-decomposed SF/sub 6/. Biological assays in our laboratory using mammalian cell culture systems have revealed that SF/sub 6/, spark-decomposed under specific experimental conditions, can produce cell death. Chemical analysis of spark-decomposed SF/sub 6/ has identified the major decomposition pathways and by-products. Biological testing of individual by-products or by-product mixtures has indicated that these major decomposition products may not account for the majority of the cell killing effects seen in our assays. Further experiments have suggested that S/sub 2/F/sub 10/ may be produced and accumulate under our specific decomposition ...
1989-07-01
Silylation of low-density silica and bridged polysilsesquioxane aerogels
Energy Technology Data Exchange (ETDEWEB)
Silica and bridged polysilsesquioxane aerogels are low-density materials that are attractive for applications such as thermal insulation, porous separation media or catalyst supports, adsorbents, and cometary dust capture agents. However, aerogels are notoriously weak and brittle making it difficult to handle and machine monoliths into desired forms. This complication prevents the development of many applications that would otherwise benefit from the use of the low-density materials. Here, we will describe our efforts to chemically modify and mechanically enhance silica-based aerogels using chemical vapor techniques without sacrificing their characteristic low densities. Monolithic silica and organic-bridged polysilsesquioxane aerogels were prepared by sol-gel polymerization of the respective methoxysilane monomers followed by supercritical carbon dioxide drying of the gels. Then the gels were reactively modified with silylating agents to demonstrate the viability ...
2004-01-01
Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea
International Nuclear Information System (INIS)
Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for this analysis is CANDU type plant, in Korea
2010-10-01
Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers
Energy Technology Data Exchange (ETDEWEB)
Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method described in IEC60112. It is found that the RPs can give visual ...
2008-10-07
Recent developments in the design of conceptual fusion reactors
International Nuclear Information System (INIS)
Since the first round of conceptual fusion reactor designs in 1973 - 1974, there has been considerable progress in design improvement. Two recent tokamak designs of the Wisconsin and Culham groups, with increased plasma beta and wall loading (power density), lead to more compact reactors with easier maintenance. The Reference Theta-Pinch Reactor has undergone considerable upgrading in the design of the first wall insulator and blanket. In addition, a conceptual homopolar energy storage and transfer system has been designed. In the case of the mirror reactor, there are design changes toward improved modular construction and ease of handling, as well as improved direct converters. Conceptual designs of toroidal-multiple-mirror, liner-compression, and reverse-field pinch reactors are also discussed. A design is presented of a toroidal multiple-mirror reactor that combines the advantages of steady-state operation and high-aspect ratio. The liner-compression reactor ...
Energy Technology Data Exchange (ETDEWEB)
Highly resistant, high-transmittance woodceramic thin films were prepared using rf magnetron sputtering of a woodceramic disk in argon plasma. A film series was deposited based on substrate temperature, which was varied from 50 to 500 degree C. The film's electrical and optical properties depended on substrate temperature. Films deposited below 300 degree C were insulative, {rho}>10{sup 10} {omega} {center_dot} cm. Films deposited at 50 degree C had a density of 1.9-2.2 g/cm{sup 3} comparable to that of single crystal graphite. Below 200 degree C, films had higher transmittance than typical DLC films in the visible and infrared region. Infrared C-H absorption spectrum was observed by Ft-IR and there exist two types of bonding corresponding to sp{sup 2} or SP{sup 3}. (author)
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
In many facilities, energy management is simply a matter of managing the energy required for lighting and space conditioning. In many others, however, energy management is much more complex and involves large motors and controls, industrial insulation, complex combustion monitoring, unique steam distribution problems, significant amounts of waste heat, etc. Typical facilities offering large energy management opportunities include industrial facilities, large office and commercial operations, government institutions such as schools, hospitals and prisons. Such facilities generally have specialized industrial, commercial or institutional processes that incorporate many of the concepts covered in other chapters. These processes require thorough analytical evaluations to determine the appropriate energy-saving measures. This chapter provides some examples. In this chapter the authors present a suggested procedure for process energy improvement. Then, motors and ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
There has been considerable interest in producing and studying nanoparticle materials because of the effect of size on their structure, physical and chemical structure. Most studied nanoparticle semiconductors belong to the II-VI group, as they are relatively easy to synthesize and are generally prepared as particulates or in thin film form. Among II-VI compounds, CdS is one of the most studied materials. There are different ways to synthesize CdS nanoparticles such as colloidal particles, chemical decomposition, sol-gel, gas evaporation, magnetron sputtering, electrostatic deposition, and etc. {gamma}-irradiation is one of the effective methods for synthesis of nanomaterials. These nonomaterials have been extensively used in the preparation of nanocrystalline metals, metal oxides, and metal-polymer composites. However, The preparation of CdS nanoparticle and CdS/ polyacrylonitrile nanocomposite by {gamma}-irradiation method at room temperature and ambient pressure. Polyacrylonitrile ...
2001-11-15
Energy Technology Data Exchange (ETDEWEB)
An ignition device of the plasma jet type is disclosed. The device has a cylindrical cavity formed in insulating material with an electrode at one end. The other end of the cylindrical cavity is closed by a metal plate with a small orifice in the center which plate serves as a second electrode. An arc jumping between the first electrode and the orifice plate causes the formation of a highly-ionized plasma in the cavity which is ejected through the orifice into the engine cylinder area to ignite the main fuel mixture. Two improvements are disclosed to enhance the operation of the device and the length of the plasma plume. One improvement is a metal hydride ring which is inserted in the cavity next to the first electrode. During operation, the high temperature in the cavity and the highly excited nature of the plasma breaks down the metal hydride, liberating hydrogen which acts as an additional fuel to help plasma formation. A second improvement consists of a cavity ...
1985-01-15
Energy Technology Data Exchange (ETDEWEB)
ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and optical region of the electromagnetic spectrum for use as ...
2003-02-01
Photoperiodic regulation of body mass and fat reserves in the meadow vole.
Short photoperiods reduce both body mass and food intake of male meadow voles. To help determine whether the primary effect of short day lengths is on regulation of some component of body mass or on the control of food consumption, voles housed in a long photoperiod were provided rations equivalent to those consumed by animals in short day lengths. Animals were transferred to a short photoperiod and after either 3 or 6 weeks of food restriction were fed ad lib. Both groups of voles overate after termination of food restriction and achieved seasonally appropriate body masses that were influenced by the duration of short photoperiod treatment. We conclude that short photoperiods gradually alter the regulated level of one or more components of body mass. We tested and failed to support the hypothesis that the subcutaneous fat depot is selectively spared during seasonal weight loss and thereby increases surface insulation. Thus, the proportion of adipose tissue ...
1986-01-01
Performance characteristics of a natural circulation cooling/latent heat storage system
Energy Technology Data Exchange (ETDEWEB)
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load conditions set basing on the result of load ...
1987-09-25
Energy Technology Data Exchange (ETDEWEB)
Onset of convection in a layer of couple-stress fluid-saturated porous medium is investigated for different types of basic temperature gradients. The boundaries are considered to be adiabatically insulated to temperature perturbations. The eigenvalue equations of the perturbed state obtained from the normal mode analysis are solved analytically using a regular perturbation technique with wave number as a perturbation parameter and also numerically using the Galerkin technique. The critical stability parameters obtained from these two techniques are in excellent agreement and an increase in the value of couple-stress parameter is found to delay the onset of convection. The results also indicate that the piecewise linear temperature profile hastens the onset of convection when compared to linear, parabolic, and inverted parabolic temperature profiles. In addition, the influence of thermal depth on the critical conditions is assessed in the case of piecewise linear ...
2010-08-15
Energy Technology Data Exchange (ETDEWEB)
The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show that a minimum reburn fuel jet velocity of 15 m/s (standard ...
1989-08-25
Natural convection cooling of a close-packed array of AGR fuel pins surrounded by graphite debris
International Nuclear Information System (INIS)
Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured temperatures over a wide range of test conditions. ...
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 American Institute of Physics.}
1999-03-01
Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon
International Nuclear Information System (INIS)
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute of Physics.
1999-03-01
Low-temperature brown rice storage by using renewable energy from snow
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. The study showed that renewable energy generated from snow piles can be used for ...
2010-07-01
Interaction of energetic beams with metals and semiconductors - a computational approach
International Nuclear Information System (INIS)
In a vacuum insulator, the narrow electron beam emitted from the cathode impinges on the anode and raises its temperature and also may produce high thermal stress. This high thermal stress, in conjuction with the surface electrostatic pressure may rupture the surface and detach particles from it. In this thesis, the interaction of high energy electron and laser beams with metals and semiconductors is investigated. The differential equations governing the physical processes involved in the interaction are solved by the finite element method. Effects of beam penetration into the material, variable beam reflectance at the surface, finite beam size and dependence of material properties on temperature are accounted for. The two-phase moving boundary problem, also known as the Stefan problem, is solved by an enthalpy formulation of the heat equation. Material deformation by thermal stresses caused by high temperature gradients and electrostatic forces induced by space ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of scrubber vessel internals is underway. A subcontractor has been ...
1993-10-22
In-vessel coolability and retention of a core melt. Volume 2
Energy Technology Data Exchange (ETDEWEB)
The efficacy of external flooding of a reactor vessel as a severe accident management strategy is assessed for an AP600-like reactor design. The overall approach is based on the Risk Oriented Accident Analysis Methodology (ROAAM), and the assessment includes consideration of bounding scenarios and sensitivity studies, as well as arbitrary parametric evaluations that allow the delineation of the failure boundaries. Quantification of the input parameters is carried out for an AP600-like design, and the results of the assessment demonstrate that lower head failure is physically unreasonable. Use of this conclusion for any specific application is subject to verifying the required reliability of the depressurization and cavity-flooding systems, and to showing the appropriateness (in relation to the database presented here, or by further testing as necessary) of the thermal insulation design and of the external surface properties of the lower head, including any ...
1996-10-01
Highlights of design and construction of Sendai Nuclear Power Station Unit No.2
International Nuclear Information System (INIS)
As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, a titanium tube condenser, a 500 kV ...
1985-01-01
Helium ion implantation in SiAlON: Characterisation of cavity structures using TEM and IBA
International Nuclear Information System (INIS)
Highly swollen nanoporous layers produced in material surfaces by He implantation are of special interest for applications such as catalysis. Here we investigate whether nanoporous layers can be produced in the covalently bonded insulating ceramic, SiAlON. The retention of highly swollen porous structures in thinned TEM sections prepared from such hard brittle materials is particularly challenging. We have successfully prepared such sections both parallel to, and perpendicular to, the implanted surface. At intermediate doses the bubble structures are very similar to those found in metals. At high helium doses local swellings at depths around the mean projected range of the He ions (#approx#360 nm) are estimated to be well in excess of 200%. Bubble structures are stable under heating to temperatures up to 1200 deg. C. It is found that the highly cavitated layer is buried below a crystalline overlayer of compact SiAlON. This overlayer is sufficiently compact to ...
2000-05-02
Energy Technology Data Exchange (ETDEWEB)
Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)
1999-11-01
Heat capacity measurements of atoms and molecules adsorbed on evaporated metal films
Energy Technology Data Exchange (ETDEWEB)
Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to study the heat ...
1989-05-01
Energy Technology Data Exchange (ETDEWEB)
First, attention is paid to the development and use of new construction techniques, including the use of new building materials, e.g. synthetic materials and the so-called steel frame method. Next, the reduction of the energy consumption during the service life of a house is discussed. The reduction can be realized by means of passive methods, e.g. improved windows, thermal insulation and design, or by means of active methods, e.g. electric load monitoring. The information in this article mainly concerns the housing construction in the USA and Canada. The purpose of this article to contribute to the discussion in the Netherlands on innovation in the building technology, e.g. formulated in the report `Bouwvisie 2010` (Vision on Buildings for the year 2010) of the Dutch Advisory Board Technology Policy for the Building Industry (ARTB, abbreviated in Dutch) and the building technology policy of the Dutch Ministry of Economic Affairs (EZ). 4 figs., 2 tabs., 23 refs.
1996-12-31
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended optical response was not detected, most likely due to the high ...
2004-12-21
Formaldehyde exposure from building products
Energy Technology Data Exchange (ETDEWEB)
Formaldehyde release from building products is primarily due to incompletely reacted urea-formaldehyde resin (UFR) in particleboard, medium density fiberboard (MDF), and plywood. Formaldehyde is also released from urea-formaldehyde foam insulation (UFFI) that was popular during the 1970s for retrofitting building envelopes. Results of the authors test of commercial adhesives and UF-bonded wood products show that current state-of-the-art products yield air chamber test values below 0.25 mg/m/sup 3/ immediately after manufacture and are capable of meeting 0.12 mg/m/sup 3/ indoor air standards at the current product ratio unless these products are used in places where they are exposed to high temperature and humidity. In mobile homes placed in severe climates, wall-temperature profiles show large seasonal and diurnal variations that cause large changes in formaldehyde indoor air levels. The authors work shows that diurnal formaldehyde levels may change by a factor of ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
For the purpose of proposing it to ISO, the R and D were conducted of a new evaluation method of thermal properties of polymer materials. The FY 1999 results were summarized. In this fiscal year, the development of the ac Joule heating equipment was proceeded with based on the study at the technical committee, and the measuring device was installed. In the comparative measurement with conventional methods, study was proceeded with of the laser flash method, AC calorimetry method and specific heat measurement. In the technical survey, the developmental state of the ac method, especially, was examined as a testing method of thermal properties of polymer materials. It is in the stage of the basic research by keyword selection, and the search for literature is to be made in full scale. As to the needs in the industrial circle, as a result of the questionnaire survey made, it was found out that there were a wide variety of the needs for general-purpose/functional film materials, forming ...
2000-03-01
Enhanced diffusion of dopants in vacancy supersaturation produced by MeV implantation
Energy Technology Data Exchange (ETDEWEB)
The diffusion of Sb and B markers has been studied in vacancy supersaturations produced by MeV Si implantation in float zone (FZ) silicon and bonded etch-back silicon-on-insulator (BESOI) substrates. MeV Si implantation produces a vacancy supersaturated near-surface region and an interstitial-rich region at the projected ion range. Transient enhanced diffusion (TED) of Sb in the near surface layer was observed as a result of a 2 MeV Si{sup +}, 1 {times} 10{sup 16}/cm{sup 2}, implant. A 4{times} larger TED of Sb was observed in BESOI than in FZ silicon, demonstrating that the vacancy supersaturation persists longer in BESOI than in FZ. B markers in samples with MeV Si implant showed a factor of 10{times} smaller diffusion relative to markers without the MeV Si{sup +} implant. This data demonstrates that a 2 MeV Si{sup +} implant injects vacancies into the near surface region.
1997-04-01
Electron flow in the SABRE linear induction adder in positive polarity
International Nuclear Information System (INIS)
In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first cavities was greater than in the simulations. The authors have extended the work on this subject with ...
1993-05-17
Electron and ion beam effects in amorphous SiO_2 and Si_3N_4 films for electronic devices
International Nuclear Information System (INIS)
The effect of electron and ion beam irradiation on the Sisub(LVV) Auger spectra of SiO_2, Si_3N_4 and Si-oxynitride films was measured by the relative intensity of the 92 eV signal, characteristic for the formation of 'free' silicon during irradiation. While in Si-oxynitride the beam effects were almost negligible, some damage was found in Si_3N_4, but SiO_2 appeared to be extremely sensitive for electron and ion beam irradiation. By low energy electron loss spectroscopy of ion bombarded SiO_2 and Si_3N_4 films new electron states due to broken Si-O and Si-N bonds could be determined within the band gap of the insulators. The measured energy losses were interpreted by means of electron energy level schemes of the amorphous films. (author).
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The effect of electron and ion beam irradiation on the Sisub(LVV) Auger spectra of SiO/sub 2/, Si/sub 3/N/sub 4/ and Si-oxynitride films was measured by the relative intensity of the 92 eV signal, characteristic for the formation of 'free' silicon during irradiation. While in Si-oxynitride the beam effects were almost negligible, some damage was found in Si/sub 3/N/sub 4/, but SiO/sub 2/ appeared to be extremely sensitive for electron and ion beam irradiation. By low energy electron loss spectroscopy of ion bombarded SiO/sub 2/ and Si/sub 3/N/sub 4/ films new electron states due to broken Si-O and Si-N bonds could be determined within the band gap of the insulators. The measured energy losses were interpreted by means of electron energy level schemes of the amorphous films.
1982-10-01
Electrical conductivity of the ceramic AIN under irradiation
Energy Technology Data Exchange (ETDEWEB)
Aluminum nitride has been proposed as electrically insulating coating in connection with blankets made of vanadium alloys. Irradiations were performed with an applied DC electric field of 100 kV/m, using a 104 MeV {alpha}-particle beam. The dose achieved were 0.1 dpa at 300 C, 0.05 dpa at 400 C, and 0.06 dpa at 500 C. The out-of-beam conductivity {sigma}{sub 0} decreased at all temperatures employed during early stage of irradiation. Before 0.02 dpa had been reached, {sigma}{sub 0} dropped to low values of typically (2-4) x 10{sup -11} ({Omega} m){sup -1}. Although a moderate increase can be observed during further irradiation, {sigma}{sub 0} remained below the initial value of the unirradiated specimen for all temperatures. That is, there is no significant evidence for radiation induced electrical degradation. The in-beam conductivity {sigma}, measured continuously during irradiation, also decreased by at least one order of magnitude. Relevant damage dose and ...
1996-10-01
Direct patterning of gold oxide thin films by focused ion-beam irradiation
International Nuclear Information System (INIS)
For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force microscopy (AFM) ...
2000-09-01
Design of the ZTH vacuum liner
Energy Technology Data Exchange (ETDEWEB)
The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to complete the torus. The thin bellows sections ...
1987-01-01
Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry
A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a transconductance of ...
2002-01-01
Design and experimental results on a terawatt magnetically controlled plasma opening switch
Energy Technology Data Exchange (ETDEWEB)
The magnetically controlled plasma opening switch (MCPOS) is an advanced plasma opening switch that utilizes magnetic fields to improve operation. Magnetic fields always dominate terawatt, pulsed power plasma opening switches. For that reason, the MCPOS uses controlled applied magnetic fields with magnitude comparable to the self-magnetic field of the storage inductor. One applied field holds the plasma in place while energy accumulates in the storage inductor, then another applied field pushes the plasma away from the cathode to allow energy to flow downstream. Over a ten month period, an MCPOS was designed, built, and tested on DECADE Module 2 at Physics International. The peak drive current was 1.8 MA in 250 ns. The output parameters were up to 1 MA into an electron beam load. The radiation temporal pulse width averaged 60 nanoseconds full-width at half-maximum. The peak load voltage ranged from one to two megavolts. The experiments demonstrated efficient power flow through a long, ...
1998-05-01
Crystal-field excitations in the visible spectrum of Nd{sub 2}CuO{sub 4}
Energy Technology Data Exchange (ETDEWEB)
A phenomenological simulation was carried out for 41 experimental crystal-field (CF) levels within the {sup 4}I{sub 9/2-15/2}, {sup 4}F{sub 3/2-9/2}, {sup 4}S{sub 3/2} and {sup 2}H{sub 9/2} J manifolds, including the available infrared (IR) data up to {approx}15 000 cm{sup -1} for the Nd{sup 3+} ions in the Nd{sub 2}CuO{sub 4} single crystals. The CF Hamiltonian for the tetragonal C{sub 4v} symmetry was diagonalized together with the free-ion Hamiltonian in a basis that spans the entire 4f{sup 3} configuration. A rms error of 9 cm{sup -1} between the calculated and experimental energy level schemes was obtained. A comparison of the spectra in the visible region between the insulating Nd{sub 2}CuO{sub 4} and the metallic Nd{sub 2-x}Ce{sub x}CuO{sub 4}, allowed identifying the absorption bands associated with the development of the charge-doping induced local structural distortions in the superconducting regime.
2004-07-14
Crystal-field excitations in the visible spectrum of Nd_2CuO_4
International Nuclear Information System (INIS)
A phenomenological simulation was carried out for 41 experimental crystal-field (CF) levels within the "4I_9_/_2_-_1_5_/_2, "4F_3_/_2_-_9_/_2, "4S_3_/_2 and "2H_9_/_2 J manifolds, including the available infrared (IR) data up to #approx#15 000 cm"-"1 for the Nd"3"+ ions in the Nd_2CuO_4 single crystals. The CF Hamiltonian for the tetragonal C_4_v symmetry was diagonalized together with the free-ion Hamiltonian in a basis that spans the entire 4f"3 configuration. A rms error of 9 cm"-"1 between the calculated and experimental energy level schemes was obtained. A comparison of the spectra in the visible region between the insulating Nd_2CuO_4 and the metallic Nd_2_-_xCe_xCuO_4, allowed identifying the absorption bands associated with the development of the charge-doping induced local structural distortions in the superconducting regime.
2004-07-14
Energy Technology Data Exchange (ETDEWEB)
Transient-enhanced diffusion (TED) during thermal annealing of ion-implanted B in Si is well established and attributed to the ion-induced, excess interstitials. On the other hand, the mechanism to account for TED of B in preamorphized (PA) Si remains unclear. Enhanced diffusion of the B persists in regrown layers even though the ion-induced interstitial defects responsible for TED in B{sup +}-only implanted Si are eliminated following regrowth. To test the hypothesis that TED in PA Si results from the {open_quotes}excess{close_quotes} interstitial-type defects below the amorphous-crystalline (a-c) interface, a buried PA layer has been recrystallized from the surface inward to the SiO{sub 2} interface of silicon-on-insulator material to eliminate all possible sources of excess interstitials. The effect on B diffusion and the role of the residual interstitial-type defects will be discussed. {copyright} {ital 1999 American Institute of Physics.}
1999-02-01
Conceptual study on advanced PWR system
Energy Technology Data Exchange (ETDEWEB)
In this study, the adoptable essential technologies and reference design concept of the advanced reactor were developed and related basic experiments were performed. (1) Once-through Helical Steam Generator: a performance analysis computer code for heli-coiled steam generator was developed for thermal sizing of steam generator and determination of thermal-hydraulic parameters. (2) Self-pressurizing pressurizer : a performance analysis computer code for cold pressurizer was developed. (3) Control rod drive mechanism for fine control : type and function were surveyed. (4) CHF in passive PWR condition : development of the prediction model bundle CHF by introducing the correction factor from the data base. (5) Passive cooling concepts for concrete containment systems: development of the PCCS heat transfer coefficient. (6) Steam injector concepts: analysis and experiment were conducted. (7) Fluidic diode concepts : analysis and experiment were conducted. (8) Wet thermal ...
1997-07-01
Conceptual design of the Fast-Liner Reactor (FLR) for fusion power
International Nuclear Information System (INIS)
The generation of fusion power from the Fast-Liner Reactor (FLR) concept envisages the implosion of a thin (3-mm) metallic cylinder (0.2-m radius by 0.2-m length) onto a preinjected plasma. This plasma would be heated to thermonuclear temperatures by adiabatic compression, pressure confinement would be provided by the liner inertia, and thermal insulation of the wall-confined plasma would be established by an embedded azimuthal magnetic field. A 2- to 3-mu s burn would follow the approx. 10"4 m/s radial implosion and would result in a thermonuclear yield equal to 10 to 15 times the energy initially invested into the liner kinetic energy. For implosions occurring once every 10 s a gross thermal power of 430 MWt would be generated. The results of a comprehensive systems study of both physics and technology (economics) optima are presented. Despite unresolved problems associated with both the physics and technology of the FLR, a conceptual power plant design is ...
Energy Technology Data Exchange (ETDEWEB)
Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other temperatures, the ...
1997-05-01
International Nuclear Information System (INIS)
Coaxial nanocables with a single-crystalline zinc telluride (ZnTe) nanowire core and an amorphous silicon oxide (SiO_x) shell have been synthesized via a simple one-step chemical vapor deposition (CVD) method on gold-decorated silicon substrates. The single-crystal ZnTe nanowire core is in zinc-blende structure along the [111] direction, while the uniform SiO_x shell fully covers the core with no observable pin-hole or crack. Formation mechanisms of the ZnTe-SiO_x nanocables are discussed. The ZnTe nanowire core shows p-type electrical properties while the SiO_x shell acts as an effective insulating layer. The ZnTe-SiO_x nanocables may have potential applications in nanoscale devices, such as p-type FETs and nanosensors.
2009-11-11
Coated semiconductor devices for neutron detection
Energy Technology Data Exchange (ETDEWEB)
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, ...
2002-01-01
CFD Analysis of a Dry Storage System for MACSTOR/KN-400
International Nuclear Information System (INIS)
There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.
2007-10-01
Breakdown of the lattice polaron picture in La{sub 0.7}Ca{sub 0.3}MnO{sub 3} single crystals
Energy Technology Data Exchange (ETDEWEB)
When heated through the magnetic transition at T{sub C}, La{sub 0.7}Ca{sub 0.3}MnO{sub 3} changes from a band metal to a polaronic insulator. The Hall constant R{sub H}, through its activated behavior and sign anomaly, provides key evidence for polaronic behavior. We use R{sub H} and the Hall mobility to demonstrate the breakdown of the polaron phase. Above 1.4T{sub C}, the polaron picture holds in detail, while below, the activation energies of both R{sub H} and the mobility deviate strongly from their polaronic values. These changes reflect the presence of metallic, ferromagnetic fluctuations, in the volume of which the Hall effect develops additional contributions tied to quantal phases. (c) 2000 The American Physical Society.
2000-04-01
A magnetically levitated electrode ionization chamber of the noncontact measurement type
Energy Technology Data Exchange (ETDEWEB)
A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the {gamma}-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ...
2002-04-01
p73 protein regulates DNA damage repair.
Although the p53 tumor suppressor is relatively well characterized, much less is known about the functions of other members of the p53 family, p73 and p63. Here, we present evidence that in specific pathological conditions caused by exposure of normal cells to bile acids in acidic conditions, p73 protein plays the predominant role in the DNA damage response. These pathological conditions frequently occur during gastric reflux in the human esophagus and are associated with progression to esophageal adenocarcinoma. We found that despite strong DNA damage induced by bile acid exposure, only p73 (but not p53 and p63) is selectively activated in a c-Abl kinase-dependent manner. The activated p73 protein induces DNA damage repair. Using a human DNA repair PCR array, we identified multiple DNA repair genes affected by p73. Two glycosylases involved in base excision repair, SMUG1 and MUTYH, were characterized and found to be transcriptionally regulated by p73 in DNA damage ...
2011-09-01
Video equipment of tele dosimetry and audio
International Nuclear Information System (INIS)
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the installation of two ...
2007-07-01
Renewable energy technology for off-grid power generation solar hybrid system
International Nuclear Information System (INIS)
Off-grid power generation is meant to supply remote or rural area, where grid connection is almost impossible in terms of cost and geography, such as island, aborigine's villages, and areas where nature preservation is concern. Harnessing an abundance renewable energy sources using versatile hybrid power systems can offer the best, least-cost alternative solution for extending modern energy services to remote and isolated communities. The conventional method for off-grid power generation is using diesel generator with a renewable energy (RE) technology utilizing solar photovoltaic, wind, biomass, biogas and/or mini/micro hydro. A hybrid technology is a combination of multiple source of energy; such as RE and diesel generator and may also include energy storage such as battery. In our design, the concept of solar hybrid system is a combination of solar with diesel genset and battery as an energy storage. The main objective of the system are to reduce the cost of operation and ...
2006-12-01
Field-effect research at the High Voltage Transmission Research Center
Energy Technology Data Exchange (ETDEWEB)
This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are analyzed for the purpose of determining the conditions for occurrence of corona in fair ...
1991-02-01
CNN Newsroom Classroom Guides, October 2000.
These classroom guides, designed to accompany the daily CNN (Cable News Network) Newsroom broadcasts for the month of October 2000, provide program rundowns, suggestions for class activities and discussion, student handouts, and a list of related news terms. Top stories include: Chinese authorities detain Falun Gong protesters on Tiananmen Square and Pope John Paul II angers China by canonizing Chinese martyrs, U.S. presidential candidates prepare for the first presidential debate, U.S. presidential candidates debate education issues, Danville, Kentucky prepares for the first U.S. vice presidential debate, and Yugoslav protesters seize parliament (October 2-6); Yugoslavian president Vojislav Kostunica takes office, recent clashes between Arabs and Israelis concern neighboring Arab states, North Korea observes 55 years of communism with celebrations, Al Gore and George W. Bush meet in the second presidential debate, and Violence in the Mideast and an attack on a ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
Details of a novel intelligent pipeline anomaly location system were presented. The system was based on the emission and reception of extra low frequencies(ELF) disposed close to a pipeline that were then logged in the memory of an in-line inspection (ILI) tool to provide a more precise reference than time-based above-ground marker systems for the location of pipeline anomalies. The system consisted of 2 pairs of transmitter (TX) and receiving (RX) circuits working at low and varied frequencies. An additional module was installed in the front section of an ILI tool, which contained a frequency transmitter whose signals are transmitted through cabling to an external transmitter and retransmitted simultaneously to a receiver installed in the rear section of an additional module of the tool in order to guarantee that the signal recorded by the tool corresponded to the smart location system. The system was used to detect anomalies in a subsea pipeline near Rio de ...
2004-07-01
A simple 5-DoF MR-compatible motion signal measurement system.
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal ...
2011-09-01
Energy Technology Data Exchange (ETDEWEB)
Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by 3V, and measures the power level at each point. Comparison is then made between the values measured at the said points on a PV profile, and the operating voltage value is ...
1997-10-30
[Magnetic thin film research]: Progress report year 2
Energy Technology Data Exchange (ETDEWEB)
The work in the past year has primarily involved four areas of magnetic thin films: amorphous rare earth-transition metal alloys, epitaxial CoPt{sub 3} and Ni-Pt alloy thin films, amorphous rare earth doped Si (a new class of dilute magnetic semiconductor with large negative magnetoresistance which the authors have discovered), and exchange-coupled antiferromagnetic insulators. In the amorphous alloys, they made a systematic study of the effects of local anisotropy, macroscopic (perpendicular) anisotropy, and exchange constant on the fundamental (and practical) properties of these magnetic alloys, as originally described in the grant proposal. The work on the epitaxial Co-Pt (and more recently Ni-Pt) alloys was originally undertaken as a comparison study to the amorphous alloys. Crystalline Co-Pt alloys have many striking similarities to the amorphous rare earth-transition metal alloys: perpendicular magnetic anisotropy, magneto-optic activity, and a {Tc} (for ...
1996-09-01
Ultra high vacuum test setup for electron gun
Energy Technology Data Exchange (ETDEWEB)
Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and vapour pressure of ...
2008-05-01
Tests with cleaned and uncleaned gas on a pilot plant. Final report
Energy Technology Data Exchange (ETDEWEB)
The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic system (combustion chamber and equipment to produce and condense steam without turbine and generator) was ...
1986-01-01
Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant
Energy Technology Data Exchange (ETDEWEB)
During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. Considering the important to safety, US NRC ...
2009-10-15
Structural stability of TiO_2 at high pressure in density-functional theory based calculations
International Nuclear Information System (INIS)
A new study on the pressure-induced phase transitions of TiO_2 has been performed using all-electron density-functional theory based computations with the projector augmented wave and the linearized augmented plane wave methods considering five experimentally observed structures. The static results yield a picture that is consistent with experiments, i.e., phase transitions with pressure are predicted as rutile #-># monoclinic baddeleyite (MI) #-># orthorhombic I (OI) #-># cotunnite (OII) on compression, and OII #-># OI #-># MI #-># columbite (TiO_2II) on decompression. The elasticities of these five polymorphs are compared. Except for the baddeleyite structure, which is considerably softer than the other polymorphs, all phases show a zero pressure bulk modulus in the range of 200-240 GPa, consistent with compression results and the single crystal elastic constant; on the basis of these results we can say that the cotunnite phase is not a superhard TiO_2 polymorph as ...
2010-07-28
Radiation-hardening of magnet coils
International Nuclear Information System (INIS)
The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnet coils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away from the beam bend - plane. Because proton beams interact with thick targets in the ...
1989-03-01
International Nuclear Information System (INIS)
The authors report on observations of plasma wave turbulence generated during electron beam injections, spacecraft potential variations, and neutral gas emissions of the CHARGE 2 sounding rocket experiment. The payload was flown in a mother/daughter configuration, with the two sub-payloads electrically connected by an insulated, conducting tether. While tethered, the two platforms were separated, drifting apart in a direction perpendicular to both the magnetic field and to the spacecraft velocity, reaching a maximum distance of 426 m at the end of the flight. The mother carried a high-voltage (HV) system (0-460 V), biasing the mother negative relative to the daughter. The operation of the HV bias system simulated the motional emf induced in larger orbiting space structures like the Tethered Satellite System 1 (TSS 1) space shuttle mission scheduled for the spring of 1992. In addition, the mother carried an electron beam accelerator (1 keV, 0-46 mA). The daughter ...
Energy Technology Data Exchange (ETDEWEB)
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, parking, inter-region ...
2003-07-01
Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface
International Nuclear Information System (INIS)
Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid overheating of top of microprotrusion is observed much sooner (over a ...
2008-12-01
Implications of high temperature superconductors for power generation
International Nuclear Information System (INIS)
Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic hydrogen at 21K. This aluminum generator is very compact and lightweight and is much more robust than a generator made with LTS because extensive thermal and magnetic shields are not ...
1991-08-03
Hydrogen analysis by p-p scattering in geological material
International Nuclear Information System (INIS)
It has been concluded by geologists that a significant amount of hydrogen is stored as point defects in nominally anhydrous minerals. Determination of the amount of hydrogen bound in these minerals is a step towards determining the total water content of the earth mantle as well as comprehending its internal water cycle. The possibility to measure hydrogen in thin geological samples by elastic p-p scattering has been investigated at the Lund Nuclear Microprobe. In this work the development of the experimental procedure and standardisation of data analysis is described. Special emphasis has been put into doing the data analysis as simple as possible and at the same time applicable to all sorts of thin samples, even those of unknown nature. A special annular surface barrier detector composed of two insulated detector halves, which are read out simultaneously, is used to detect the recoiled proton and the scattered proton in coincidence. Conditions on the difference ...
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on almost all the surfaces ...
1995-12-31
Graded layer design for stress-reduced and strongly adherent superhard amorphous carbon films
Energy Technology Data Exchange (ETDEWEB)
Diamond-like carbon thin films for tribological applications were deposited by d.c.-magnetron sputtering of a graphite target in a pure argon atmosphere or in a reactive hydrogen or methane atmosphere at pressures between 0.1 and 1 Pa in a graded constitution to improve adhesion and reduce residual stress. The temperature of the metallic, carbon- and ceramic-like substrates was below 100 C. The mechanical, thermal, electronic and optical properties of the carbon thin films show a significant dependence on the ion energy. Below 220 eV, strongly adherent black conductive films with hardness values up to 2000 HV0.05 were obtained. Hard and superhard diamond-like carbon thin films were deposited in an energy range between 220 and 370 eV with hardness values up to 4000 HV0.05. They are insulating, optically transparent and show a high degree of hardness combined with high compressive stress in the order of 4 GPa as well as a low adhesion, which means that the critical ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to investigate the feasibility and the optimal conditions of radiofrequency (RF) ablation by using the stent-type electrode upon the saphenous vein of goats for the endovenous treatment of varicose veins. A self-expandable nitinol stent electrode (6 mm diameter, 2 cm length, cell size; 1.3 x 2 mm) was designed to expose the distal 1 cm segment to allow for contact with the venous wall. The proximal part of the electrode was connected to the RF generator by insulated copper wires located within the stent electrode introducer. Initially, to optimize the power setting, ablation of 6 saphenous veins in 3 goats was performed with power settings of 10, 20 and 30 W. Pull back rate of the electrode was 2 and 4 cm/min for each power level, respectively. The goats were sacrificed 4-6 weeks later and histologic examinations of the saphenous veins were done. For the second part of the experiment, RF ablation of 4 saphenous veins from 2 goats was ...
2004-10-15
Effects of ion-induced electron emission on magnetron plasma instabilities
International Nuclear Information System (INIS)
Some magnetron sputtering systems experience rapid oscillations in the current and voltage of the plasma discharge after several hours when equipped with certain targets. These oscillations often lead to the plasma becoming extinguished, a condition known as ''flame-out.'' This article details the study of two 90% W--10% Ti magnetron targets which differed in density. The higher density targets sometimes experienced flame-out after approximately 3 h of sputtering. The less dense material could be sputtered for the entire 15 h life of the target. Scanning electron microscopy pictures and atomic composition depth profiles were obtained using Auger electron spectroscopy. In addition, a Colutron-based ion source with a high vacuum system was used to measure ion-induced secondary electron emission coefficients as a function of energy, ion specie, and gas coverage. Analysis of the sample from the group that suffers flame-out showed large regions of pure titanium in the interior of the sample ...
Energy Technology Data Exchange (ETDEWEB)
The rare-earth based nickelates RNiO{sub 3} (R = Pr, Nd, Sm, Eu, and Pr{sub 1-x}La{sub x}, 0{<=}x{<=}0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R{sup 3+} site within the electronic ground-state J multiplet (for R = Pr, Nd, and Pr{sub 1-x}La{sub x}) as well as within the two lowest-lying J multiplets (for R = Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed variation of the CEF parameters in an ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
The rare-earth based nickelates RNiO{sub 3} (R=Pr, Nd, Sm, Eu, and Pr{sub 1-x}La{sub x}, 0{<=}x{<=}0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R{sup 3+} site within the electronic ground-state J multiplet (for R=Pr, Nd, and Pr{sub 1-x}La{sub x}) as well as within the two lowest-lying J multiplets (for R=Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed variation of the CEF parameters in an effective ...
1999-12-01
International Nuclear Information System (INIS)
The rare-earth based nickelates RNiO_3 (R=Pr, Nd, Sm, Eu, and Pr_1_-_xLa_x, 0#<=#x#<=#0.7) were studied by inelastic neutron scattering. Energy splittings due to the crystalline-electric-field (CEF) interaction at the R"3"+ site within the electronic ground-state J multiplet (for R=Pr, Nd, and Pr_1_-_xLa_x) as well as within the two lowest-lying J multiplets (for R=Sm and Eu) were directly observed, and the corresponding CEF energy-level schemes were reconstructed. The latter were rationalized in terms of CEF parameters, which vary smoothly over the rare-earth series and give magnetic properties associated with the R sublattice in agreement with results from neutron powder diffraction experiments. Across the metal-insulator transition, a continuous change in the electronic part of the CEF parameters is observed. However, an attempt to quantify a charge transfer from the observed variation of the CEF parameters in an effective point charge model failed, ...
1999-12-01
Construction, testing of the 1 MW, 130-260 GHz Fusion-FEM
Energy Technology Data Exchange (ETDEWEB)
During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS particle-tracking code and the TOSCA code. The TOSCA code is used for accurate field ...
1995-12-31
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for reading. As part of the ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, which are sent to an outside vendor for reading. As part of the ...
1996-09-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
