WorldWideScience
1

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

2

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to ...

2007-08-21

3

Stabilization of measuring channel of reflective gamma thickness gage by light pulses from additional scintillator  

International Nuclear Information System (INIS)

Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.

4

New Radiation Stable and Long-Lived Plastic Scintillators  

International Nuclear Information System (INIS)

A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic ...

1993-11-15

5

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per ...

1996-05-01

6

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the ...

7

Development of Novel Polycrystalline Ceramic Scintillators  

Energy Technology Data Exchange (ETDEWEB)

For several decades most of the efforts to develop new scintillator materials have concentrated on high-light-yield inorganic single-crystals while polycrystalline ceramic scintillators, since their inception in the early 1980 s, have received relatively little attention. Nevertheless, transparent ceramics offer a promising approach to the fabrication of relatively inexpensive scintillators via a simple mechanical compaction and annealing process that eliminates single-crystal growth. Until recently, commonly accepted concepts restricted the polycrystalline ceramic approach to materials exhibiting a cubic crystal structure. Here, we report our results on the development of two novel ceramic scintillators based on the non-cubic crystalline materials: Lu SiO:Ce (LSO:Ce) and LaBr:Ce. While no evidence for texturing has been found in their ceramic microstructures, our LSO:Ce ceramics ...

2008-06-01

8

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

9

Large scintillation cells for high sensitivity radon concentration measurements  

Energy Technology Data Exchange (ETDEWEB)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length ...

1983-07-01

10

Large scintillation cells for high sensitivity radon concentration measurements  

International Nuclear Information System (INIS)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length ...

11

Synthesis and scintillation properties of GdCl_3:Ce"3"+ (Gd_1_-_xCe_xCl_3_,x = 0.005-0.08)  

International Nuclear Information System (INIS)

Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).

2009-07-08

12

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The ...

2002-06-01

13

SCINTILLATION COUNTERS  

Science.gov (United States)

... 89 11 August 195Z SCINTILLATION COUNTERS *Subtask uder Effects of Irradiation, AMRL Project No. ... 89 SCINTILLATION COUNTERS* by ...

1952-08-11

14

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

15

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

16

New crystals for dual-readout calorimetry  

CERN Document Server

Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.

2009-01-01

17

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...

1992-10-25

18

The AMS-02 electromagnetic calorimeter  

CERN Document Server

The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

2002-01-01

20

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

21

Distribution Models for Optical Scintillation Due to ...  

Science.gov (United States)

... Lincoln Laboratory Distribution Models for Optical Scintillation Due to Atmospheric Turbulence RR Parenti RJ Susiela Group 107 ...

2005-12-12

22

Comparative Equatorial Scintillation Morphology--American ...  

Science.gov (United States)

... Accession Number : ADA066094. Title : Comparative Equatorial Scintillation Morphology--American and Pacific Sectors. ...

1978-06-30

23

Study of the light yield of LuAP:Ce scintillating crystals  

Energy Technology Data Exchange (ETDEWEB)

We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.

1996-12-31

24

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

25

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

26

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

27

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

28

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

29

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

30

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

31

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning ...

1990-11-01

33

Atmospheric Scintillation Effects on Electromagnetic Weapons  

Science.gov (United States)

... 4. TITLE AND SUBTITLE Atmospheric Scintillation Effects on Electromagnetic Weapons 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. ...

2008-12-01

34

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the ...

1990-12-20

35

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the ...

1990-12-01

37

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

38

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to ...

2000-01-01

39

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is ...

2006-11-13

40

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to ...

2006-06-15

41

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to ...

2006-06-01

42

Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system  

Energy Technology Data Exchange (ETDEWEB)

Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in the vessel was ...

1998-01-01

43

The Study of Phosphors Efficiency and Homogeneity using a Nuclear Microprobe  

Energy Technology Data Exchange (ETDEWEB)

Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was found to be low for organic materials, due to saturation of the light output dependence on the energy deposition of heavy ...

2000-12-08

44

Optical modules for the neutrino telescope KM3NeT  

Energy Technology Data Exchange (ETDEWEB)

KM3NeT is a future deep-sea research infrastructure hosting a neutrino telescope with a volume of at least one cubic kilometer to be constructed in the Mediterranean Sea. The experiment aims to detect high-energy cosmic neutrinos using a 3D array of optical modules to collect the Cherenkov light induced by charged particles in the water. Upward going muons and showers produced in neutrino interactions with the surrounding matter will allow the search and study of possible sources of extra-terrestrial neutrinos. The design of optical modules makes an important impact on the performance and cost of the KM3NeT project. Several different optical module configurations are under consideration; based on glass pressure spheres containing: a large (10 in.) hemispherical photomultiplier tube (with a multi-anode version as an option); 25-31 3 in. photomultiplier tubes, or a crystal scintillator-based hybrid device (X-HPD). The features and advantages of ...

2010-11-01

45

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

46

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

47

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

48

Scintillation Velocity of PSR B0329+54  

Science.gov (United States)

We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.

2011-07-01

50

Scintillation converter screen investigation for real-time neutron radiography  

International Nuclear Information System (INIS)

(1980). United States Panhuise, VE Bull, SR Seydel, JA Univ of Missouri-

1980-11-21

51

Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating  

International Nuclear Information System (INIS)

The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).

52

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...

1996-12-31

53

NASA's Real World: The Light Plants Need - NASA  

Science.gov (United States)

light-emitting diode A light-emitting diode, or LED, is a semi-conductor light source that emits visible light or invisible infrared radiation. Semi-conductors ...

54

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

55

Computer model of high-latitude scintillation. [WBMOD program  

Energy Technology Data Exchange (ETDEWEB)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

1982-01-01

56

Computer model of high-latitude scintillation  

International Nuclear Information System (INIS)

The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.

57

Impact of Ionospheric Scintillations on Space-Based ...  

Science.gov (United States)

... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...

1991-06-01

58

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

59

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

60

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

61

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

62

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

63

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

64

The Effect of Cocktail on Radiocarbon Analysis by Direct Absorption of Carbon dioxide  

International Nuclear Information System (INIS)

Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency

1998-12-01

65

Aqueous liquid scintillation counting with fluor-containing nanosuspensions  

Energy Technology Data Exchange (ETDEWEB)

A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.

2004-06-01

66

Mid-latitude scintillation model. Technical report, 1 November 1985-31 October 1986  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective ...

1986-10-31

67

A novel method for solving lithium carbonate pellet by binary-acid for tritium production rate measurement by liquid scintillation counting technique  

International Nuclear Information System (INIS)

Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the ...

68

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

69

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

70

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

71

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

72

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

73

Light Infantry Division Assessment  

Science.gov (United States)

... LIGHT INFANTRY DIVISION ASSESSMENT LOl 0 BY ... TYPE OF REPORT & PERIOD COVERED LIGHT INFANTRY DIVISION ASSESSMENT ...

1990-04-02

74

The Light Infantry Division: How Many Are Needed  

Science.gov (United States)

Page 1. .v~ -. *° THE LIGHT INFANTRY DIVISION-HOW MANY ARE NEEDED? ,"- Lfl ... 7- Light Infantry Light Infantry Division 20. ...

1985-05-10

77

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...

78

An analysis on the mid-latitude scintillation and coherence frequency bandwidth using transionospheric VHF signals  

Energy Technology Data Exchange (ETDEWEB)

An analysis was perfonned on the mid-latitude scintillation and coherence frequency bandwidth (Fcoh) using transionospheric VHF signal data. The data include 1062 events spanning from November 1997 to June 2002. Each event records FORTE satellite received VHF signals from LAPP located at Los Alamos, New Mexico. Fcohs were derived to study scintillation characteristics on diurnal and seasonal variations, as well as changes due to solar and geomagnetic activities. Comparisons to the VHFIUHF coherence frequency bandwidth studies previously reported at equatorial and mid-latitude regions are made using a 4th power frequency dependence relationship. Furthennore, a wideband ionospheric scintillation model, WBMOD, was used to estimate Fcohs and compared with our VHF Fcoh values. Our analysis indicates mid-latitude scintillation characteristics that are not previously revealed. At the VHF bottom frequency range ...

2008-01-01

79

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

80

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.

2011-02-01

82

CERN's 'Big Bang' experiment given green light  

CERN Document Server

CERN's 'Big Bang' experiment given green light

2008-01-01

83

Bilayer Lipid Membranes for Light Converters  

International Science & Technology Center (ISTC)

Bilayer Lipid Membrane Supported Novel Photoelectrochemical Converter for Light Trapping

84

Big Bang experiment given green light  

CERN Document Server

Big Bang experiment given green light

2008-01-01

85

[Hadroproduction of charmed and bottom mesons (Fermilab experiment E-653): Progress report, June 13, 1983--June 14, 1984  

Energy Technology Data Exchange (ETDEWEB)

(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproduction on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of elastic events. ...

1984-12-31

86

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, ...

1999-07-01

87

Scintillation proximity assay for measurement of RNA methylation  

UK PubMed Central (United Kingdom)

Methylation of RNA by methyltransferases is a phylogenetically ubiquitous post-transcriptional modification that occurs most extensively in transfer RNA (tRNA) and ribosomal RNA (rRNA). Biochemical...Full Text Available

2009-03-01

88

Measurement of cosmic ray neutron spectrum at sea level  

International Nuclear Information System (INIS)

The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).

89

LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay  

British Library Electronic Table of Contents (United Kingdom)

LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.

2011-01-01

90

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

91

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

92

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

93

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

94

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

95

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

96

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

97

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

98

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

99

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

100

Wire-shaped semiconductor light-emitting diodes for general-purpose lighting  

Energy Technology Data Exchange (ETDEWEB)

The object of this work is to develop and optimize a new type of light-emitting diode (LED) with a wire-shaped, cylindrical geometry.

2002-10-28

101

Light Weight Composite Mirrors for Science Instruments  

Science.gov (United States)

Light Weight Composite Mirrors for Science Instruments. Composite Optics, Inc. San Diego, CA. INNOVATION. Light weight, large aperture reflectors of graphite ...

104

Intraband Absorptoin of Far-Infrared Light by Electrons in ...  

Science.gov (United States)

... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...

1999-06-18

105

Equatorial scintillation model. Technical report, 1 February 1983-30 April 1985  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the ...

1985-09-30

106

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...

1998-06-01

107

Atmospheric scintillations and laser safety  

Science.gov (United States)

Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that ...

2011-09-01

108

Advanced Lighting Program Development (BG9702800) Final Report  

Energy Technology Data Exchange (ETDEWEB)

The report presents a long-range plan for a broad-based, coordinated research, development and market transformation program for reducing the lighting energy intensities in commercial and residential buildings in California without compromising lighting quality. An effective program to advance lighting energy efficiency in California must be based on an understanding that lighting is a mature field and the lighting industry has developed many specialized products that meet a wide variety of light needs for different building types. Above all else, the lighting field is diverse and there are applications for a wide range of lighting products, systems, and strategies. Given the range of existing lighting solutions, an effective energy efficient lighting research portfolio must be ...

1998-02-01

109

Investigation of methods for improving models of ionospheric plasma-density irregularities and radio-frequency scintillation. Technical report  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.

1993-11-01

110

Improved model of high-latitude F-region scintillation (WBMOD version 13). Final report, 1 September 1993-31 August 1994  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.

1994-08-31

111

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

112

Phenomenological study of light-induced effects in #alpha#-Al_2O_3:C  

International Nuclear Information System (INIS)

A computerised glow curve deconvolution (CGCD) analysis was applied to the main dosimetric peak of #alpha#-Al_2O_3:C in order to study the effects of light on the glow curve shape. It was shown that both the light-induced signal and the light-induced fading effects tend to shift the main dosimetric peak to higher temperatures and at the same time change its shape. Furthermore it was confirmed that the magnitude of the light-induced signal depends on radiation history and, by increasing the duration of light exposure, the magnitude of the light-induced signal reaches a plateau, thereby implying the saturation of the phototransfer process. (author).

1995-07-10

113

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

114

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

115

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

116

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

117

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

118

Lighting in indoor environments: Visual and non-visual effects of light sources with different spectral power distributions  

British Library Electronic Table of Contents (United Kingdom)

Since the end of the 1990s, good quality lighting was that which balanced the needs of humans, economic and environmental issues, and architectural design. Recent studies aimed to find a correlation between environmental lighting and human performance and health, with positive results. What is known, is that insufficient or inappropriate light exposure can disrupt standard human rhythms which may result in adverse consequences for performance, safety, health. By studying the relationship between human physiology and light, research in photobiology has advanced to the point where some attempts to foresee what the lighting practice will be in future. The question is if lighting practice and lighting practitioners are ready for changes. This paper has the aim of introducing the recent discove...

2011-01-01

119

Longitudinal light clock and Lorentz distortions  

CERN Document Server

The transverse light clock, in uniform translatory motion, is usually adopted to prove the necessity of the relativistic time dilation, according to the invariance of the velocity of the light, while the former postulate of the Special Relativity is respected by the symmetrical behavior of the clock. In this paper it is instead demonstrated that the behavior of the moving longitudinal light clock must involve unusual Lorentz distortions of the space, travelled by the light, to respect both the postulates of the Special Relativity.

2011-01-01

120

Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography  

Science.gov (United States)

The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.

1986-05-01

121

Searches for Fast Radio Transients  

CERN Document Server

We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.

2003-01-01

122

Search for tachyons associated with extensive air showers in the ground level cosmic radiation  

International Nuclear Information System (INIS)

Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.

1985-08-01

123

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

124

Quality engineering and control semiannual progress report November and December 1976 and January--April 1977  

International Nuclear Information System (INIS)

Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.

125

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

126

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

127

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

128

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

129

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

130

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

131

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

132

A search for tachyons in extensive air showers  

International Nuclear Information System (INIS)

A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).

133

A search for tachyons in cosmic ray showers  

International Nuclear Information System (INIS)

A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.

134

Semi-empirical formula for #LAMBDA#-binding energies in ground states of light hypernuclei  

International Nuclear Information System (INIS)

Starting with a #LAMBDA#-nucleus potential, a semi-empirical formula, which gives a fairly satisfactory account of the ground state #LAMBDA#-binding energy of light hypernuclei, if the very light nuclei are ignored has been obtained. (author).

135

Clinical Efficacy of Self-applied Blue Light Therapy for Mild-to-Moderate Facial Acne  

UK PubMed Central (United Kingdom)

This study was an evaluation of the performance of self-applied, blue light, light-emitting diode therapy in the treatment of mild-to-moderate inflammatory acne on the face, concerning: 1) time to improvement...Full Text Available

2009-03-01

136

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

137

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

138

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

139

The Limits of Spacepower  

Science.gov (United States)

... to light-light a laser or directed energy weapon would ... space-based components... .the most likely threats are direct ascent anti-satellite weapons; ...

2001-05-18

140

A Computer Vision System for Inspection of Light Emitting ...  

Science.gov (United States)

... Accession Number : ADD801284. Title : A Computer Vision System for Inspection of Light Emitting Diodes. Descriptive Note : Conference paper,. ...

1986-06-01

142

Stored light and released fiction  

CERN Document Server

It is shown that the interpretation of the experimental results reported in the publication "Storage of Light in Atomic Vapor" by D.F.Phillips et al., Phys. Rev.Lett. 86, 783 (2001) [quant-ph/0012138] is incorrect. The experimental observation of this paper can be consistently explained in the framework of standard concepts of the physics of optical pumping and has nothing to do with "storage of light", or "dynamic reduction of the group velocity", or "light pulse compression".

2003-01-01

144

Shedding Synchrotron Light on a Puzzle of Glasses  

ScienceCinema

...introduced english ...the range of simple english ...the range of simple english ...

145

STS-134: Go for Launch  

National Aeronautics and Space Administration (NASA)

Endeavour is given the green light after all prelaunch

2011-05-16

146

Radiation hardening of optical fiber links by photobleaching with light of shorter wavelength  

International Nuclear Information System (INIS)

The influence of additionally injected short-wavelength photobleaching light on the radiation hardness of Ge-doped graded index fibers working at 1,300 nm wavelength is investigated. Predictions are complicated by the fact that more efficient shortwave bleaching light experiences higher radiation-induced loss. Promising results are found for low fiber temperatures (approx-lt -50 C) and bleaching light of about 835 nm wavelength.

1995-09-18

149

Heavy and light quarks in the instanton vacuum  

CERN Document Server

Assuming the gluon field is well approximated by instanton configurations we derive a light quarks determinant and calculate its contribution to the specific heavy quarks correlators -- namely, the heavy quark propagator and heavy quark-aniquark correlator, receiving the instanton generated light-heavy quarks interaction terms contributions. With these knowledge we calculate the light quark contribution to the interaction between heavy quarks, which might be essential for the properties of a few heavy quarks systems.

2011-01-01

153

BOOKMARKS:  

Wastenet

Institutional and organizational models ... Review individual centre institutional and organizational models in the light of the tasks to be

154

BC  

Wastenet

Institutional and organizational models ... Review individual centre institutional and organizational models in the light of the tasks to be performed by

155

Vacuum structures in Hamiltonian light-front dynamics  

Energy Technology Data Exchange (ETDEWEB)

Hamiltonian light-front dynamics of quantum fields may provide a useful approach to systematic nonperturbative approximations to quantum field theories. The authors investigate inequivalent Hilbert-space representations of the light-front field algebra in which the stability group of the light front is implemented by unitary transformations. The Hilbert space representation of states is generated by the operator algebra from the vacuum state. There is a large class of vacuum states besides the Fock vacuum which meets all the invariance requirements. The light-front Hamiltonian must annihilate the vacuum and have a positive spectrum. Relations are exhibited of the Hamiltonian to the nontrivial vacuum structure. 30 refs.

1994-03-01

156

Self-seeded injection-locked FEL amplifier  

Energy Technology Data Exchange (ETDEWEB)

A self-seeded free electron laser (FEL) provides a high gain and extraction efficiency for the emitted light. An accelerator outputs a beam of electron pulses to a permanent magnet wiggler having an input end for receiving the electron pulses and an output end for outputting light and the electron pulses. An optical feedback loop collects low power light in a small signal gain regime at the output end of said wiggler and returns the low power light to the input end of the wiggler while outputting high power light in a high signal gain regime.

1998-12-01

157

Revisiting light neutralino scenarios in the MSSM  

CERN Document Server

We revisit the case of a light neutralino LSP in the framework of the MSSM. We consider a model with eleven free parameters. We show that all scenarios where the annihilation of light neutralinos rely mainly on the exchange of a light pseudoscalar are excluded by direct detection searches and by Fermi measurements of the gamma-flux from dwarf spheroidal galaxies. On the other hand, we find scenarios with light sleptons that satisfy all collider and astroparticle physics constraints. In this case, the lower limit on the LSP mass is 12.6 GeV. We discuss how the parameter space of the model will be further probed by new physics searches at the LHC.

2011-01-01

158

Gravitational Waves and the Sagnac Effect  

CERN Document Server

We consider light waves propagating clockwise and other light waves propagating counterclockwise around a closed path in a plane (theoretically with the help of stationary mirrors). The time difference between the two light propagating path orientations constitutes the Sagnac effect. The general relativistic expression for the Sagnac effect is discussed. It is shown that a gravitational wave incident to the light beams at an arbitrary angle will not induce a Sagnac effect so long as the wave length of the weak gravitational wave is long on the length scale of the closed light beam paths. The gravitational wave induced Sagnac effect is thereby null.

2003-01-01

159

Standardization of "2"4"1Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting  

International Nuclear Information System (INIS)

The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

2009-09-07

160

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

161

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of ...

1986-01-01

162

Detection system characteristics using sup 252 Cf ionization chambers  

Energy Technology Data Exchange (ETDEWEB)

Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...

1990-01-01

163

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is ...

1992-03-16

164

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...

2005-10-23

165

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

166

Use of activated charcoal for the purification of neon in the CLEAN experiment  

Energy Technology Data Exchange (ETDEWEB)

Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.

2007-01-21

167

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

168

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

169

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...

2007-12-15

170

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

171

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

172

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

173

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

174

Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea  

Science.gov (United States)

The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.

2011-09-01

175

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

176

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

177

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...

1999-11-01

178

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-21

179

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-11

180

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

181

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

182

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

183

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

184

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

185

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

186

Suppression of pitting corrosion with passive film modification on type 304 stainless steel by ultra-violet light irradiation; Shigaikoshosha ni yoru Type 304 stainless ko no fudotai himaku kaishitsu to koshoku yokusei  

Energy Technology Data Exchange (ETDEWEB)

In this study, the effects of 325nm wavelength ultraviolet light irradiation on pitting corrosion behavior of type 340 stainless steel in a neutral chloride solution are studied. Further, the change of passive film with the light irradiation is analyzed using x-ray photoelectron spectroscopy. The mains results obtained therefrom are stated below. Pitting potential can be shifted in noble direction by the ultraviolet light irradiation. The effect of ultraviolet light irradiation is ore prominent in the pitting corrosion process than that in the passive film formation. The result of the analysis in terms of the birth and death stochastic probability process shows that pitting corrosion rate is decreased remarkably by the ultraviolet light irradiation at the formation of passive film, while the repassivation is slightly expedited by the ultraviolet light ...

1998-06-20

187

A study of light hydrocarbons (C{sub 4}-C{sub 1}3) in source rocks and petroleum fluid  

Energy Technology Data Exchange (ETDEWEB)

This thesis consists of an introduction and five included papers. Of these, four papers are published in international journals and the fifth was submitted for review in April 2000. Emphasis has been placed on both naturally and artificially generated light hydrocarbons in petroleum fluids and their proposed source rocks as well as direct application of light hydrocarbons to oil/source rock correlations. Collectively, these papers describe a strategy for interpreting the source of the light hydrocarbons in original oils and condensates as well as the source of the asphaltene fractions from the reservoir fluids. The influence of maturity on light hydrocarbon composition has also been evaluated. The papers include (1) compositional data on the light hydrocarbons from thermal extracts and kerogen pyrolysates of sediment samples, (2) light hydrocarbon data of oils ...

2000-07-01

188

Technique for compressing light intensity ranges utilizing a specifically designed liquid crystal notch filter  

Energy Technology Data Exchange (ETDEWEB)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.

1988-01-01

189

High-power operation of heterobarrier blocking structure InGaAlP visible light laser diodes  

Energy Technology Data Exchange (ETDEWEB)

Heterobarrier blocking structure InGaAlP visible light laser diodes employing a thin active layer (0.04 {mu}m) and asymmetry coatings have been fabricated. The high light-output power operation with this heterobarrier blocking structure was investigated. The light-output power versus cw current curve was linear up to 43 mW and a maximum light output power of 51 mW was obtained. A high-power operation such as 20 mW was maintained at 40 {degree}C. Stable oscillation in the fundamental transverse mode was obtained up to 30 mW. These results show that this heterobarrier blocking structure supplies a sufficient current confinement effect even under a high-light output power operation.

1990-04-30

190

Visible-light resin-curing units: retinal hazards and protective lenses. Final report, December 1982-May 1986  

Energy Technology Data Exchange (ETDEWEB)

The potential retinal hazard of dental visible-light photopolymerization units and the efficacy of protective lenses for reducing the potential hazards were assessed. The spectral radiance profiles of 11 visible-light photopolymerization units were measured; and the results were then weighted according to the American Conference of Governmental Industrial Hygienists (ACGIH) Blue Light and Thermal Hazard Functions. The results indicate that there are no thermal hazards to the retina even for the worst case condition. None of the blue-light hazard maximum permissible exposure times is short enough to be of concern unless the individual operator chooses to focus on the light source for an extended period. Those individuals who elect to stare at the light during curing procedures should consider the purchase of protective lenses. The special transmission profiles of ...

1986-11-01

191

Variation in the action spectrum of erythrolabe among deuteranopes.  

UK PubMed Central (United Kingdom)

1. Eight deuteranopes matched a mixture of a monochromatic light on the long wave side of the neutral point and a violet (450 nm) primary to a fixed white as well as a monochromatic light on the short...Full Text Available

1977-04-01

192

Retinal channelrhodopsin-2-mediated activity in vivo evaluated with manganese-enhanced magnetic resonance imaging  

UK PubMed Central (United Kingdom)

PurposeEctopic expression of light-sensitive proteins, such as channelrhodopsin-2, represent a novel approach for restoring light-detection capabilities to degenerated retina. A...Full Text Available

193

Rapid Correlation between the Leaves of Spinach and the Photocontrol of a Peroxidase Activity 1  

UK PubMed Central (United Kingdom)

The activity of a basic peroxidase extracted at high pH from spinach (Spinacia oleracea) leaves is modified by an irradiation with 2-minute red light or 2-minute far red light. This...Full Text Available

1982-02-01

194

Preliminary results from an advanced lighting controlstestbed  

Energy Technology Data Exchange (ETDEWEB)

Preliminary results from a large-scale testbed of advanced lighting control technologies at the Phillip Burton Federal Building at 450 Golden Gate Ave. in San Francisco are presented. The first year objective of this project is to determine the sustainable energy savings and cost-effectiveness of different lighting control technologies compared to a portion of the building where only minimal controls are installed. The paper presents the analyzed results from six months of tests focused on accurately characterizing the energy savings potential of one type of daylight-linked lighting controls compared to the lighting in similar open-planned areas without dimming controls. After analyzing a half year;s data, we determined that the annual energy savings for this type of daylight- linked controls was 41% and 30% for the outer rows of lights on the South and North sides of the building, ...

1998-03-01

195

Phytochrome Control of Maize Coleoptile Section Elongation 1  

UK PubMed Central (United Kingdom)

A rapid loss of far red light (FR) reversibility of red-light (R) stimulated elongation of maize coleoptile sections was observed. Reversal was not possible when the interval between R and FR treatment...Full Text Available

1981-02-01

196

Photographic measurements of the diffuse light in the coma cluster  

International Nuclear Information System (INIS)

The diffuse background light in the Coma cluster is measured using isodensity tracings of B, G, V, and R photographic plates taken with the Palomar 1.2-m Schmidt telescope. The isodensity contours are calibrated using the star profile derived by Kormendy (1973). Between 4 and 14 arc min from the center, the surface brightness of the diffuse light decreases from approximately 26 to approximately 28 G magnitudes arc sec"-"2. The total magnitude in this annulus is G = 11.22, which is approximately 45 percent of the light in galaxies alone, or approximately 30 percent of the total. This does little to alleviate the ''missing mass'' problem. The isodensity contours and the equivalent profile of the diffuse light closely parallel the distribution of light in galaxies, implying no strong mass segregation. However, the background light appears to be bluer than the ...

197

Light duty utility arm startup plan  

Energy Technology Data Exchange (ETDEWEB)

This plan details the methods and procedures necessary to ensure a safe transition in the operation of the Light Duty Utility Arm (LDUA) System. The steps identified here outline the work scope and identify responsibilities to complete startup, and turnover of the LDUA to Characterization Project Operations (CPO).

1998-09-01

198

Light amplifier with filtering of spontaneous background  

Energy Technology Data Exchange (ETDEWEB)

A comparitive analysis is made of the principal characteristics of narrow-band and conventional semiconductor light amplifiers. It is shown that quasi-distributed filtering of the spontaneous radiation ensures a high gain and a low level of the spontaneous noise at the amplifier output.

1980-06-01

199

Increased Sensitivity to Light-Induced Melatonin Suppression in Premenstrual Dysphoric Disorder  

UK PubMed Central (United Kingdom)

Increased sensitivity to light-induced melatonin suppression characterizes some, but not all, patients with bipolar illness or seasonal affective disorder. The aim of this study was to test...Full Text Available

2010-08-01

200

Far-Red Light-Induced Changes in Intracellular Potentials of Spinach Mesophyll Cells  

UK PubMed Central (United Kingdom)

In green plants, the large bioelectric changes that photosynthetically active light stimulates make it difficult to observe electrical potential changes related to phytochrome photoconversion. As a...Full Text Available

1983-11-01

201

Experimental Differential Light-Scattering Correction to the Circular Dichroism of Bacteriophage T2  

UK PubMed Central (United Kingdom)

Experimental techniques are presented that can be used to assay and correct for differential light scattering effects in circular dichroism spectra of biological macrostructures. The assay is based...Full Text Available

1973-01-01

202

Electrical - light current remote monitoring, control and automation. [Coal mine, United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

A brief discussion is given of the application of control monitoring and automation techniques to coal mining in the United Kingdom, especially of the use of microprocessors, for the purpose of enhancing safety and productivity. Lighting systems for the coal mine is similarly discussed.

1981-06-01

203

Development of circadian rhythmicity and light responsiveness in the rat suprachiasmatic nucleus: a study using the 2-deoxy[1-14C]glucose method.  

UK PubMed Central (United Kingdom)

The suprachiasmatic nucleus (SCN) of the hypothalamus is thought to play a critical role in circadian rhythm generation and entrainment to the light/dark cycle. In adult rats, the SCN shows a circadian...Full Text Available

1980-02-01

204

DNA Damage during G2 Phase Does Not Affect Cell Cycle Progression of the Green Alga Scenedesmus quadricauda  

UK PubMed Central (United Kingdom)

DNA damage is a threat to genomic integrity in all living organisms. Plants and green algae are particularly susceptible to DNA damage especially that caused by UV light, due to their light dependency...Full Text Available

205

Crystallographic structure of xanthorhodopsin, the light-driven proton pump with a dual chromophore  

UK PubMed Central (United Kingdom)

Homologous to bacteriorhodopsin and even more to proteorhodopsin, xanthorhodopsin is a light-driven proton pump that, in addition to retinal, contains a noncovalently bound carotenoid with a function...Full Text Available

2008-10-28

206

Characterization of the Key Step for Light-driven Hydrogen Evolution in Green Algae*  

UK PubMed Central (United Kingdom)

Under anaerobic conditions, several species of green algae perform a light-dependent hydrogen production catalyzed by a special group of [FeFe] hydrogenases termed HydA. Although highly interesting...Full Text Available

2009-12-25

207

Antisense Expression of the CK2 ?-Subunit Gene in Arabidopsis. Effects on Light-Regulated Gene Expression and Plant Growth1  

UK PubMed Central (United Kingdom)

The protein kinase CK2 (formerly casein kinase II) is thought to be involved in light-regulated gene expression in plants because...Full Text Available

1999-03-01

208

A Turquoise Mutant Genetically Separates Expression of Genes Encoding Phycoerythrin and Its Associated Linker Peptides  

UK PubMed Central (United Kingdom)

During complementary chromatic adaptation (CCA), cyanobacterial light harvesting structures called phycobilisomes are restructured in response to ambient light quality shifts. Transcription of genes...Full Text Available

2002-02-01

209

Weyl gauge, Schwinger terms and bosonization in light-front field theory  

Energy Technology Data Exchange (ETDEWEB)

A systematic study of non-perturbative quantum structure of the massive light-front Schwinger model and QED(3+1) in the continuum formulation is outlined. The light-front Hamiltonian and field algebra are derived in the Weyl gauge using the Dirac-Bergmann constrained quantization. Unitary transformation to the light-cone gauge representation is performed and the gauge-invariant fermi field is constructed. The importance of the Schwinger term in the current-current commutation relations for the derivation of the fermionic vacuum structure and bosonization in two dimensions is indicated.

2002-04-01

210

The distribution of mass-to-light ratio with radius in M31 and M33  

International Nuclear Information System (INIS)

1974. Netherlands Baldwin, JE Cambridge Univ. (UK). Cavendish Lab. Reidel.;

211

Light Scalar Mesons as Manifestation of Spontaneously Broken Chiral Symmetry  

CERN Document Server

Attention is paid to the production mechanisms of light scalars that reveal their nature. We reveal the chiral shielding of the \\sigma(600) meson. We show that the kaon loop mechanism of the \\phi radiative decays, ratified by experiment, points to the four-quark nature of light scalars. We show also that the light scalars are produced in the two photon collisions via four-quark transitions in contrast to the classic P wave tensor q\\bar q mesons that are produced via two-quark transitions $\\gamma\\gamma\\to q\\bar q$. The history of spontaneous breaking of symmetry in quantum physics is discussed in Appendix.

2010-01-01

214

The Participation of Two Rhythms in the Leaf Movements of Xanthium Plants Given Various Light-Dark Cycles 1  

UK PubMed Central (United Kingdom)

We have shown Xanthium strumarium exhibit two distinct leaf movement rhythms with one occurring in continuous light and presumably related to an endogenous rhythm initiated by the “light-on”...Full Text Available

1974-02-01

215

Static-static-light-light tetraquarks in lattice QCD  

CERN Document Server

I report on a lattice computation of the energy of a system of two light quarks and two static antiquarks as a function of the separation of the static antiquarks. In terms of hadrons such a system corresponds to a pair of B mesons and its energy to the hadronic potential. I present selected results for different isospin, spin and parity combinations of the individual B mesons mainly focusing on those channels relevant to determine, whether two B mesons may form a bound tetraquark state.

2011-01-01

216

Rapid Respiratory Changes Due to Red Light or Acetylcholine during the Early Events of Phytochrome-mediated Photomorphogenesis 1  

UK PubMed Central (United Kingdom)

Two millimeter long secondary root tips of etiolated mung bean (Phaseolus aureus) plants were given 4 minute consecutive treatments of darkness, red light, far red light, and acetylcholine...Full Text Available

1972-01-01

217

Observations of time delayed all-optical routing in a slow light regime  

CERN Document Server

We report an observation of a delayed all-optical routing/switching phenomenon based on ultraslow group velocity of light via nondegenerate four-wave mixing processes in a defected solid medium. Unlike previous demonstrations of enhanced four-wave mixing processes using the slow light effects, the present observation demonstrates a direct retrieval of the resonant Raman-pulse excited spin coherence into photon coherence through coherence conversion processes.

2008-01-01

218

Observations of photon echo enhancement in an ultraslow light regime  

CERN Document Server

Using spectral hole-burning-based ultraslow group velocity in a dilute solid medium, we report enhanced photon echo efficiency three orders of magnitude higher than that in a nonslow light regime. The enhancement is due to exponentially increased absorption of an optical data pulse owing to the enhanced photon-atom interaction in an ultraslow light regime, whereas echo reabsorption is negligibly small due to group-velocity dependent population depletion.

2011-01-01

219

Loss of light charged particles by nuclear interactions in BaF[sub 2] crystals  

Energy Technology Data Exchange (ETDEWEB)

The nuclear interaction probability of light charged particles in BaF[sub 2] crystals has been studied as a function of the incident particle energy. Light charged particles were identified in charge and mass by measuring their magnetic rigidity and their time-of-flight. The percentage of particles undergoing nuclear interactions has been measured for particles of charge from Z=1 to Z=6 and the experimental data are compared with the results of a model calculation. (orig.)

1993-07-15

220

Assimilation of [15N]Nitrate and [15N]Nitrite in Leaves of Five Plant Species under Light and Dark Conditions 1  

UK PubMed Central (United Kingdom)

Light dependency of nitrate and nitrite assimilation to reduced-N in leaves remains a controversial issue in the literature. With the objective of resolving this controversy, the light requirement for...Full Text Available

1983-02-01

221

A class of finite one-loop light-cone integrals  

Energy Technology Data Exchange (ETDEWEB)

Using the manifestly causal gluon propagator in the light-cone gauge, we evaluate two one-loop Feynman integrals which appear in the computation of the three-gluon vertex correction in the two-component formalism of the Yang-Mills gauge fields. We conclude that they both are finite for {omega} -> 2, where {omega} is the dimensional regulator. They belong to a class of finite one-loop light-cone integrals. (author). 7 refs.

1992-10-01

222

A study of the projectile break-up mechanism at intermediate energies by means of the multidetector ARGOS  

Energy Technology Data Exchange (ETDEWEB)

The reaction mechanism underlying the 44 MeV/u {sup 40}Ar projectile break-up process has been studied on different targets, by measuring the coincidences between light particles or intermediate mass fragments detected in a large angular range, and projectile fragments or light charged particles. While the experimental data relative to projectile-like fragments (PLF) with charge close to the one of the projectile can be interpreted in the framework of a three source analysis, the anomalous light fragment production with Z {<=} 10 rather suggests `fission` as one of the possible decay mode of the highly excited projectile or PLF. It is also observed that a great amount of the forward detected light charged particles are correlated, and due to the break-up or decay of light excited ions. (author). 9 refs.

1996-09-01

223

Research and development of photovoltaic power system. Study on structural defects in silicon-based amorphous materials; Taiyoko hatsuden system no kenkyu kaihatsu. Amorphous silicon kei zairyo no kozo kekkan ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Described herein are the results of the FY1994 research program for structural defects of silicon-based amorphous materials for solar cells. The study on light generation defects of the a-Si:H system and rejuvenation process by annealing establishes the effects of light irradiation time on changed neutral dangling bond density as a result of light irradiation at varying temperature of 77K, room temperature and 393K. The study on annealing to rejuvenate light generation defects of various types of a-Si-H systems establishes the activation energy distribution with respect to annealing to remove light-induced defects, showing that hydrogen affects the distribution of light-induced defects. The study on decaying process of light-induced ESR for undoped and N-doped a-Si:H systems observes the decaying process of light-induced ...

1994-12-01

224

Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.  

Energy Technology Data Exchange (ETDEWEB)

Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...

1998-10-07

225

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

226

Standardisation of "2"1"0Pb by Cerenkov counting  

International Nuclear Information System (INIS)

A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.

2011-05-01

227

Radon measurements at the FEMP  

Energy Technology Data Exchange (ETDEWEB)

Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.

1993-08-01

228

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

229

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

230

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

231

Improvement of a radiochemical separation for selenium 79: Applications to effluents and nuclear wastes.  

Science.gov (United States)

Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740

2007-01-14

232

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

233

Electronic structures of luminescence centers in pure and defective scintillation crystals AWO4 (A = Pb, Cd, Zn)  

International Nuclear Information System (INIS)

The electronic structures of the set of molecular clusters of dielectric oxide crystals AWO4 (A = Pb, Cd, Zn), the sizes of which increase sequentially are ab-initio calculated by the Restricted Hartree-Fock (RHF) method. The results of calculations of molecular orbitals and energy dependences of partial densities of electronic states of different clusters are compared each to other and to experimental data. It is found that calculated electronic structures of the tungstate groups and cations which are surrounded in cluster by certain number of the nearest neighbor atoms of the crystals quite well represent the experimentally obtained value of the forbidden gap of corresponding AWO4 crystal. (authors)

234

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

235

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross section is a well known standard one. The result of the {sup ...

1997-07-01

236

White luminescence of Tm-Dy ions co-doped aluminoborosilicate glasses under UV light excitation  

International Nuclear Information System (INIS)

Tm3+ and Dy3+ ions co-doped aluminoborosilicate glasses were prepared in this study. The luminescence properties of the glasses were analyzed. A combination of blue, green, yellow, and red emission bands was shown for these glasses, and white light emission could be observed under UV light excitation. White light luminescence color could be changed by varying the excitation wavelength. Concentration quenching effect was investigated in this paper. Furthermore, the dependence of luminescence properties on glass compositions was studied. Results showed that the luminescence intensity changed with different network modifier oxides, while the white color luminescence was not affected significantly. - Graphical abstract: Tm3+ and Dy3+ ions co-doped aluminoborosilicate glasses, which emit white light under UV light excitation, were prepared. The dependence of luminescence properties on ...

2008-10-01

237

Scattered Light from Close-in Extrasolar Planets: Prospects of Detection with the MOST Satellite  

CERN Document Server

The ultra-precise photometric space satellite MOST (Microvariability and Oscillations of STars) will provide the first opportunity to measure the albedos and scattered light curves from known short-period extrasolar planets. Due to the changing phases of an extrasolar planet as it orbits its parent star, the combined light of the planet-star system will vary on the order of tens of micromagnitudes. The amplitude and shape of the resulting light curve is sensitive to the planet's radius and orbital inclination, as well as the composition and size distribution of the scattering particles in the planet's atmosphere. To predict the capabilities of MOST and other planned space missions, we have constructed a series of models of such light curves, improving upon earlier work by incorporating more realistic details such as: limb darkening of the star, intrinsic granulation noise in the star itself, tidal ...

2003-01-01

238

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

239

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

240

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...

2004-07-19

241

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

242

Towards an understanding of the light scalar mesons  

Energy Technology Data Exchange (ETDEWEB)

Although studied for many years the nature of the light scalar mesons remains controversial. Here we shall present a method, applicable for s-wave states located close to a threshold, that allows one to quantify the molecular part of a given state. When applied to the f{sub 0}(980) a dominance of the molecular component is found. In the second part, we show that requirements of field-theoretic consistency and chiral symmetry, when applied to the scattering of light pseudo-scalars, naturally lead to the appearance of dynamical poles in the scalar sector. A program is proposed on how to further investigate experimentally the mixing between these dynamical states and possible genuine quark states. (orig.)

2007-03-15

243

The influence of multiple photoperiods and pinealectomy on gonads, pelage and body weight in male meadow voles, Microtus pennsylvanicus.  

Science.gov (United States)

1. Chronic exposure of male Microtus pennsylvanicus to photoperiods with 8, 10 and 12 hr of light per day results in gonadal regression, molt to winter pelage and significant reductions in body weight and food consumption relative to voles kept on photoperiods with 13 and 14 hr of light per day. 2. A precise critical daylength is observed in this species as exposure to photoperiods with 12 or fewer hours of light per day results in complete gonadal involution, seasonal molt and loss of body weight. 3. Pinealectomy abolishes all short-photoperiod induced responses in this species. PMID:2573458

1989-01-01

244

Safe hole trapping, light soaking and secondary photocurrent transients in amorphous silicon  

International Nuclear Information System (INIS)

A new analysis is developed for long secondary photocurrent transients which gives the distribution of trapped holes in valence band tail states. Thermally assisted tunneling to dangling bonds is implicated as the rate limiting step in hole-recombination. Light-soaking causes the energetically deeper hole traps with the longer residence times to be lost first and in the same number as would be expected for the increase in dangling bonds; This result supports a model which has hole trapping in valence tail states as a precursor to light induced dangling bonds.

1988-09-26

245

Radiation effect on optical, electrophysical and surface properties of GaAlAs heterostructures  

Energy Technology Data Exchange (ETDEWEB)

A study was made on the effect of 3.5 MeV electron irradiation on the properties of light-emissive structure based on GaAlAs. It is shown that a considerable decrease in the emitted light intensity as a result of electron irradiation not accompanied by changes in recombination- and electric properties of the mentioned structures. It is established by the electron-microscopy and Auger-spectroscopy meazurements that electron irradiation causes the occurrence of regions of free aluminium clusters on the external surface of the structure n-layer. The number and the sizes of the regions depend on the electron doze. It was assumed that the mentioned regions can play a role of attenuation filter for the light emitted by the structure.

1984-07-01

246

Fourier Synthesization of Optical Pulses and "Polar'' Light  

CERN Document Server

It is shown that the direct Fourier synthesization of light beams allows one to create polarity-asymmetric waves, which are able, in the process of nonlinear interaction with a medium, to break its inversion symmetry. As a result, these "polar" waves may show the effect of optical rectification in nonlinear centrosymmetric media by generating light-induced dc electric polarization. At the same time, the waves of this type, due to their unusual symmetry properties, can be used for detecting the direction and sign of a dc electric field applied to the medium. The prospects of application of polar waves to data recording and processing are discussed.

2002-01-01

247

Comparison of the green- and infrared-stimulated luminescence of feldspar  

Energy Technology Data Exchange (ETDEWEB)

The differences are highlighted of various aspects of behaviour of the luminescence signal from feldspar when stimulated by green light and when stimulated by infrared radiation. In respect of bleaching, a comparison is made of the influence of white light (daylight) on the two stimulated luminescence signals, as well as a comparison of the influence of infrared exposure on the green-stimulated signal with the influence of green exposure on the infrared-stimulated signal. The influence of preheating on the two stimulated signals is also compared. Light-emitting diode systems were used for both green and infrared stimulation. The observations are considered in relation to the mechanism relevant to green- and infrared-stimulated luminescence from feldspar. (author).

1994-04-01

248

Comparison of the green- and infrared-stimulated luminescence of feldspar  

International Nuclear Information System (INIS)

The differences are highlighted of various aspects of behaviour of the luminescence signal from feldspar when stimulated by green light and when stimulated by infrared radiation. In respect of bleaching, a comparison is made of the influence of white light (daylight) on the two stimulated luminescence signals, as well as a comparison of the influence of infrared exposure on the green-stimulated signal with the influence of green exposure on the infrared-stimulated signal. The influence of preheating on the two stimulated signals is also compared. Light-emitting diode systems were used for both green and infrared stimulation. The observations are considered in relation to the mechanism relevant to green- and infrared-stimulated luminescence from feldspar. (author).

1993-07-01

249

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

250

Black holes and tachyons  

International Nuclear Information System (INIS)

Given a Schwarzschild black-hole, the frame sigma at rest with respect to the Schwarzschild metric are chosen as reference-frames. In this locally non-inertial frames, a free falling body is shown to reach the speed of light on the horizon and then to travel faster-than-light inside the horizon. The usual Szekeres-Kruskal (SK) coordinates represent themselves frames that (with respect to the frames sigma) travel at subliminal speed outside, at luminal speed on, and at superluminal speed inside the horizon (so that SK frames always describe any free falling body as a standard, slower-than-light object). At last, black-holes are shown to be possible sources of tachyons.

251

Angular distributions of light charged particles from /sup 252/Cf fission in the ranges 0-46/sup 0/ and 134-180/sup 0/  

Energy Technology Data Exchange (ETDEWEB)

Alpha particles, tritons, deuterons and protons accompanying /sup 252/Cf fission were registered in coincidence with both fission fragments by means of a system containing two-dimensional position-sensitive silicon detectors. Angular distributions, kinetic energy spectra of light charged particles as well as mass distributions of fission fragments in coincidence with light charged particles were measured. The experimental results are compared with some theoretical models.

1985-06-03

252

lightsources.org: An Internet Site for Light SourceCommunication  

Energy Technology Data Exchange (ETDEWEB)

Research at the world's accelerator- (storage-ring and linac) based light sources is one of the most dynamic and rapidly growing fields of science. It frequently results in direct benefits to society, thereby demonstrating the value of the research with very concrete examples, but this is not widely understood or appreciated outside of the immediate user community. Our growing group of light source communicators from facilities in Europe, Asia, and the Americas, inspired by the Interactions.org Web site created by high-energy (elementary-particle)physics communicators, concluded that a light source community Web site (lightsources.org) would be the best tool for establishing effective collaboration between the communications offices of the world's light sources and to maximize the impact of our efforts. We envision lightsources.org to serve as a one-stop-shopping site for information ...

2004-10-04

253

f 07821-6004-R0-00 RESEARCH PROGRAM ON HOLOGRAPHIC - NASA ...  

Science.gov (United States)

in a KDP crystal fed with red light from a Q-s_tched ruby laser. One reason for interest in holograms made with ultraviolet ...

254

Synchronizing Fire Support for Heavy/Light Operations: A ...  

Science.gov (United States)

... Division and the 82nd ABN Division spearheaded a ... attack through the stalled 90th Division to ... mi,_es, which included airborne infantrv, regular ...

1989-11-27

255

Stability studies on refined soybean oil stored in various conditions  

International Nuclear Information System (INIS)

The 12 months stability study of freshly produced refined soybean oil revealed that refined soybean oil stored in plastic containers in dark was more hydrolytically and oxidatively stable than that stored in other containers in light condition. There was no significant difference at P < 0.05 in free fatty acids and acid value of oil stored under light and dark conditions in tin and glass containers but there was significant difference at P < 0.05 in peroxide value of oil stored in light and dark conditions in all the storage containers. Light increased the degree of oxidative rancidity of refined soybean oil, the most in tin containers, followed by glass containers and the least in plastic containers. (author)

2008-01-01

256

Simulating the operation of photosensor-based lighting controls  

International Nuclear Information System (INIS)

Energy savings from the use of daylighting in commercial buildings are realized through implementation of photoelectric lighting controls that dim electric lights when sufficient daylight is available to provide adequate workplane illumination. The dimming level of electric lighting is based on the signal of a photosensor. Current simulation approaches for such systems are based on the questionable assumption that the signal of the photosensor is proportional to the task illuminance. This paper presents a method that simulates the performance of photosensor controls considering the acceptance angle, angular sensitivity, placement of the photosensor within a space, and color correction filter. The method is based on the multiplication of two fisheye images: one generated from the angular sensitivity of the photosensor and the other from a 180- or 360-degree fisheye image of the space as ''seen'' by the photosensor. The paper ...

257

SS 433 as a black hole candidate  

Energy Technology Data Exchange (ETDEWEB)

The inverse problem of interpreting the SS 433 optical light curves is solved for a geometrically thick model accretion disk around the compact relativistic object: most likely a black hole.

1985-01-01

258

Physiological Considerations of Fatigue  

Science.gov (United States)

your eye to the SCN in your brain, so that light ... Owls are individuals who go to bed late, like to get up late in the moming. And the moming types, ...

259

Pegasus Unbound? The Challenge of Sustainment and ...  

Science.gov (United States)

... 124 Headquarters, 82nd Airborne Division, 82nd Airborne Division Airborne Standing Operating Procedures ... the Light Infantry divisions during the ...

2005-05-26

260

PRA In Design - NASA Technical Report Server (NTRS)  

Science.gov (United States)

developing a consensus PRA standard for non- associated guidance light water reactor applications that will address some aspects of PRA in design. ...

261

PLASMA JET WELDING, COATING, AND CUTTING: AN ...  

Science.gov (United States)

... 31. New electric forming methods offer potentials for light metals; magnetic forming and plasma forming. ... 3, 25 Magnetic Forming ..... ...

1963-02-01

262

Optical Diffraction Studies of Muscle Fibers  

UK PubMed Central (United Kingdom)

A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available

1973-09-01

265

Increasing the Ground Tactical Mobility Of US Airborne Forces ...  

Science.gov (United States)

... public and civilian leadership considers the Insertion of the 82nd ... C+7, an airborne/light division by C+ 12, two heavy divisions by C+30, ...

1992-12-17

266

GRBs Light Curves - Another Clue on the Inner Engine  

CERN Document Server

The nature of the `inner engine' that accelerate and collimate the relativistic flow at the cores of GRBs is the most interesting current puzzle concerning GRBs. Numerical simulations have shown that the internal shocks' light curve reflects the activity of this inner engine. Using a simple analytic toy model we clarify the relations between the observed $ \\gamma $-rays light curve and the inner engine's activity and the dependence of the light curves on the inner engine's parameters. This simple model also explains the observed similarity between the observed distributions of pulses widths and the intervals between pulses and the correlation between the width of a pulse and the length of the preceding interval. Our analysis suggests that the variability in the wind's Lorentz factors arises due to a modulation of the mass injected into a constant energy flow.

2002-01-01

267

Functional changes of the visual system of the damselfish Dascyllus marginatus along its bathymetric range  

British Library Electronic Table of Contents (United Kingdom)

Shallow-water zooplanktivorous fish rely on their vision for foraging. In shallow water, feeding efficiency decreases in dim light and thus the fish cease foraging at crepuscular hours. Creatures living in the lower parts of their depth ranges are expected to be exposed to limited light levels for longer hours. However, observations of the zooplanktivore Dascyllus marginatus showed little change in foraging duration down to 40m deep. We asked whether the visual system's functionality changes with depth along the depth range of this damselfish; we examined eye and retina anatomy for changes in visual acuity and light sensitivity and used the optomotor response to test for spatial and temporal light summation. We found only minor changes in the anatomy of the eye that are not expected to aff...

2010-01-01

268

Frequency mixing crystal  

Energy Technology Data Exchange (ETDEWEB)

In a laser system for converting infrared laser light waves to visible light comprising a source of infrared laser light waves and means of harmoic generation associated therewith for production of light waves at integral multiples of the frequency of the original wave, the improvement of said means of harmonic generation comprising a crystal having the chemical formula X.sub.2 Y(NO.sub.3).sub.5 .multidot.2 nZ.sub.2 o wherein X is selected from the group consisting of Li, Na, K, Rb, Cs, and Tl; Y is selected from the group consisting of Sc, Y, La, Ce, Nd, Pr, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Al, Ga, and In; Z is selected from the group consisting of H and D; and n ranges from 0 to 4.

1992-01-01

269

Fermion-boson symmetry through superluminal transformations  

Energy Technology Data Exchange (ETDEWEB)

We consider the Pauli theorem on the spin-statistics connection for faster-than-light particles. As the consequence of the unlocalizability of tachyons in space we conclude that their spin-statistics correlations are inverted.

1985-08-01

270

FG Sge at the stage of dust shell ejection  

British Library Electronic Table of Contents (United Kingdom)

New photometric observations of the variable star FG Sge, a rapidly evolving planetary nebula nucleus, were performed in 2003?2008. On 230 nights, we obtained 86 UBV and 155 BV RI (or R c , I c ) magnitude estimates. The maximum amplitude of the V-band light variations was >8 m . Six deep minima and four high maxima were observed. Analysis of the light curve has shown that the pulsation period of the star remained constant since 1991 and was P = 115 days. We have studied the wavelength dependence of the extinction at various phases of the light curve. The blueing of the B-V color at deep minima is interpreted as the result of light scattering in the circumstellar dust shell of the star formed by preceding dust ejections since 1992. Our spectroscopic observations performed on nine nights in...

2009-01-01

271

Effects of seed maturation time and dry storage on light and temperature requirements during germination in invasive Prosopis juliflora  

British Library Electronic Table of Contents (United Kingdom)

The effects of time of seed maturation and dry seed storage and of light and temperature requirements during seed incubation on final germination percentage and germination rate were assessed for the invasive shrub Prosopis juliflora (Sw.) D.C., grown under desert environmental conditions of the United Arab Emirates (UAE). Seeds were collected from Fujira on the northern coast of the UAE at different times during the growing seasons (autumn, winter and spring) and were germinated immediately and after 8 months of dry storage under room temperature (20+-3degreeC). Seeds were germinated at three temperatures (15, 25 and 40degreeC) in both continuous light and darkness. The results showed significant effects for time of seed collection, seed storage, light and temperature of seed incubation a...

2006-01-01

272

Differences in morphology, gas exchange and root hydraulic conductance before planting in Pinus canariensis seedlings growing under different fertilization and light regimes  

British Library Electronic Table of Contents (United Kingdom)

As the main forestry species in the Canary Islands (Spain), Pinus canariensis is frequently used in afforestation programs. Several nursery techniques are commonly employed to modify its morphology and physiology with the aim of improving post-planting survival and growth. In this work, we studied how fertilization and light regime treatments applied during the nursery period modify biomass allocation patterns and produce effects in gas exchange and root hydraulic conductance. Seedlings were grown for a 6-month period in the nursery under two light regimes (full sunlight and 40% PAR reduction), and three fertilization levels were applied in each light regime. Morphology, biomass allocation patterns, leaf gas exchange and hydraulic conductance of the whole root system were evaluated. Fertil...

2010-01-01

273

Demonstration of a Tunable-Bandwidth White Light Interferometer using Anomalous Dispersion in Atomic Vapor  

CERN Document Server

The concept of the 'white-light cavity' has recently generated considerable research interest in the context of gravitational wave detection. Cavity designs are proposed using negative (or anomalous) dispersion in an intracavity medium to make the cavity resonate over a large range of frequencies and still maintain a high cavity build-up. This paper presents the first experimental attempt and demonstration of white-light effect in a meter long ring cavity using an intracavity atomic medium. The medium's negative dispersion is caused by bi-frequency Raman gain in an atomic vapor cell. Although the white light condition was not perfectly achieved and improvements in experimental control are still desirable, significantly broad cavity response over bandwidth greater than 20 MHz has been observed. These devices will have potential applications in new generation laser interferometer gravitational wave detectors.

2006-01-01

274

CASPAR: Low-Cost, Dual-Manifest Payload Adapter for ...  

Science.gov (United States)

... being designed for projected Minotaur IV launch load environments, with design objectives of light weight, integrated vibration isolation, low shock ...

2011-05-14

275

Big bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

A brief review of standard big bang nucleosynthesis theory and the related observations of the light element isotopes is presented. Implications of BBN on chemical evolution and constraints on particle properties will also be discussed.

2000-01-01

276

Basic characteristics of centrifuges, (2)  

International Nuclear Information System (INIS)

The presence of an extraneous light gas must be taken into account in consideration of centrifugal separation of uranium isotopes, when there is inevitable leakage of such a gas through the gas sealant and/or leaking in from the atmosphere. Consideration is first given to the influence of the presence of the light gas on the maximum separative power. Then the basic equation for isotope separation containing a light gas is derived from Hirschfelder's diffusion equations. This equation is solved and the separative performance is expressed in terms of the shape factor and reflux parameter. The formulas for expressing the flow configurations of the gases are obtained for a simple model in which inflow and outflow prevail throughout the centrifuge. The corresponding equation for a model in which the gases flow in two concentric thin streams is also derived. It is concluded that the influence provided by the presence of a ...

277

BOSTON UNIVERSITY GRADUATE SCHOOL OF ARTS AND SCIENCES - NASA  

Science.gov (United States)

green (both light and dark tones) and purple, bare areas are seen in ...... spatial scale continue to plague such efforts. Knowledge of the spatial ...

278

Army Transformation to Expeditionary Formations  

Science.gov (United States)

... gap" between the arrival ofquick response forces, such as the 82nd Airborne Division and the ... nd Airborne is just exactly that, light airborne infantry. ...

2011-05-14

280

Advanced synchronous luminescence system  

Energy Technology Data Exchange (ETDEWEB)

A method and apparatus for determining the condition of tissue or otherwise making chemical identifications includes exposing the sample to a light source, and using a synchronous luminescence system to produce a spectrum that can be analyzed for tissue condition.

1997-01-01

281

ADVANCED INTERNAL COMBUSTION ENGINE USING JET FUELS ...  

Science.gov (United States)

NASA 1996 STTR Phase I. Proposal Number: 960022. Project Title: ADVANCED INTERNAL COMBUSTION ENGINE USING JET FUELS FOR LIGHT AIRCRAFT ...

282

A gravitational diffusion model without dark matter  

UK PubMed Central (United Kingdom)

In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available

1998-03-31

283

A child with hyperferritinemia: Case report  

UK PubMed Central (United Kingdom)

Hereditary hyperferritinemia cataract syndrome (HHCS) is a rare condition caused by mutations in the gene coding for the light chain of ferritin; it does not lead to iron overload, but it is associated...Full Text Available

284

Vehicular traffic flow at a intersection controlled by signal light with a new probability  

CERN Document Server

We introduced a probability of traffic light, PL, at an intersection when approaching cars in two roads are in same conditions. As a application, we proposed a modified Nagel-Schreckenberg cellular automata model for describing a conflicting vehicular traffic flow at the intersection. The results show that the plateau region in the fundamental diagrams, caused by the effect of interaction, is dependent not only on the probability PL, but also on the adaptive schemes.

2009-01-01

285

The application of MOX fuel in light water nuclear power plant  

International Nuclear Information System (INIS)

MOX fuel has been one of the mature nuclear fuels which can be used in light water nuclear power plant now. The development status in this domain in foreign countries, the major influence of MOX fuel on reactor performance and the countermeasures are introduced in this paper. The application of MOX fuel in China's PWR is discussed in the end. (authors)

2008-12-01

286

Survey of Flue Gas Desulfurization Systems: La Cygne Station, Kansas City Power and Light Co.  

Science.gov (United States)

The report gives results of a second survey of the flue gas desulfurization (FGD) system on Unit 1 of Kansas City Power and Light Co.'s La Cygne Station. The FGD system, first started up in February 1973 and commercially available in June 1973, uses a lim...

1978-01-01

287

Survey of Flue Gas Desulfurization Systems, Lawrence Power Station, Kansas Power and Light Co.  

Science.gov (United States)

The report gives results of a survey of the flue gas desulfurization (FGD) systems at Kansas Power and Light Co.'s Lawrence Power Station. The systems utilize boiler injection of pulverized limestone, followed by tail-end wet scrubbing: unit 4, with a net...

1975-01-01

288

Survey of Flue Gas Desulfurization Systems Hawthorn Station, Kansas City Power and Light Co.  

Science.gov (United States)

The report gives results of a survey of the flue gas desulfurization (FGD) systems at Kansas City Power and Light Co.'s Hawthorn Power Station. The FGD systems on Hawthorn boilers 3 and 4 were designed to operate by injection of dry limestone in the boile...

1975-01-01

289

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

290

Steelbiz Shop  

Wastenet

... The composite ground floor is suitable for support to all types of wall construction and can be used equally well on strip footings or mini-pile foundations . The light steel edge beams provide the accurate template required for internal timber or light steel wall frames to minimise fitting time and eliminate rework. The floated slab surface will accept floor finishes directly and thermal insulation can be easily fitted beneath ...

291

Reflective diffraction grating  

Energy Technology Data Exchange (ETDEWEB)

Reflective diffraction grating. A focused ion beam (FIB) micromilling apparatus is used to store color images in a durable medium by milling away portions of the surface of the medium to produce a reflective diffraction grating with blazed pits. The images are retrieved by exposing the surface of the grating to polychromatic light from a particular incident bearing and observing the light reflected by the surface from specified reception bearing.

2003-06-24

292

Quantum theory of light interstitial diffusion and other aspects of inert gas motion in solids  

International Nuclear Information System (INIS)

Most diffusion phenomena in solids can be understood (or sometimes misunderstood) on a purely classical model. For light interstitials (hydrogen isotopes, the positive muon, and potentially He) there may be anomalous temperature dependences, and isotope effects, and anomalous response to electric fields and temperature gradients. Some of these anomalies are quantal in origin, and will be discussed. (author).

1980-03-01

293

Propulsion by tachyon beams  

Energy Technology Data Exchange (ETDEWEB)

A possibility of generating collimated beams of faster-than-light particles (tachyons) and using them for rocket propulsion is explored. The relativistic rocket equations are derived, and are solved for a single-stage rocket with constant mass flow rate, constant exhaust velocity and no coasting period. The features of these solutions for faster-than-light exhaust velocities are discussed. It is shown that a tachyon drive would not violate the first law of thermodynamics. However, as seen in the Galactic frame, it would violate the second law.

1989-07-01

294

Optic probe for semiconductor characterization  

Energy Technology Data Exchange (ETDEWEB)

Described herein is an optical probe (120) for use in characterizing surface defects in wafers, such as semiconductor wafers. The optical probe (120) detects laser light reflected from the surface (124) of the wafer (106) within various ranges of angles. Characteristics of defects in the surface (124) of the wafer (106) are determined based on the amount of reflected laser light detected in each of the ranges of angles. Additionally, a wafer characterization system (100) is described that includes the described optical probe (120).

2008-09-02

295

New injection equipment for high-speed Diesel engines  

Energy Technology Data Exchange (ETDEWEB)

A high-speed light-Diesel engine with direct injection has been developed by the Institute of Combustion Engines, Graz. Thanks to light construction throughout, exhaust gas supercharger and noise-reduced composition a Diesel engine could be built that is comparable to Otto-cycle engines as regards performance, weight, aggregate size and noise production but far superior to these with respect to fuel consumption and exhaust gas emission.

1982-09-01

296

Molecular basis of factor VIII inhibition by human antibodies. Antibodies that bind to the factor VIII light chain prevent the interaction of factor VIII with phospholipid.  

UK PubMed Central (United Kingdom)

Most antibodies to factor VIII have recently been shown to react with discrete regions of the factor VIII light chain (within the C2 domain) and/or the factor VIII heavy chain (within the amino-terminal...Full Text Available

1989-06-01

297

Light emission from grazing incidence interaction of light ions with clean Cu(110)  

International Nuclear Information System (INIS)

Photon yields were measured from Cu(110) bombarded by H"+, H_2"+ and He"+ with different energies. The energy dependence is different from previous studies at perpendicular incidence. A calculation of the energy dependence of resonant charge capture into the n=3 state of H is compared with experiment. (G.Q.).

1983-02-04

298

Evaluation of two-beam spectroscopy as a plasma diagnostic  

Energy Technology Data Exchange (ETDEWEB)

A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

1980-04-01

299

Design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1981-01-01

300

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

301

A computer program for estimating decommissioning costs for light water reactors  

Energy Technology Data Exchange (ETDEWEB)

This report discusses a desk-top computer program has been developed for estimating the costs, waste volumes, and occupational radiation exposures associated with decommissioning light-water reactor power stations. Cost categories and cost algorithms used in the program are discussed and a brief description of the user interface is given.

1993-02-01

302

Using light to bioactivate surfaces: A new way of creating oriented, active immunobiosensors  

International Nuclear Information System (INIS)

Ultraviolet light can be used to immobilize biomolecules onto thiol reactive surfaces in order to, e.g., make biosensors. The mechanism involves light-induced formation of free, reactive thiol groups in disulphide containing molecules. This technology allows for the creation of arrays of biomolecules with a high degree of reproducibility, circumventing the need for often expensive nano/micro-dispensing technologies. The ultimate size of the immobilized spots is defined by the focal area of the UV beam. Light-induced immobilization has the added benefit that the immobilized molecules will be spatially oriented and covalently bound to the surface. In this paper, we demonstrate the utility of a sensor array created with the new sensor technology when integrated into a microfluidic system. Protein arrays made using light-induced immobilization showed successful antigen/antibody binding in a flow cell ...

2007-12-15

303

Photocatalytic activities of AgSbO3 under visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

A novel visible light sensitive photocatalyst, AgSbO3 was prepared by a conventional solid-state reaction method. This oxide belonging to a cubic-pyrochlore structure can absorb visible light with wavelength up to about 480nm. From the band structure calculation, we found that the top of the valence band consists of the hybridized Ag 4d and O 2p orbitals and the bottom of the conduction band mainly consists of the Ag 5s and the Sb 5s orbitals. Photocatalytic activities were evaluated using O2 evolution from an aqueous silver nitrate solution and decomposition of gaseous 2-propanol under visible light irradiation. We found that AgSbO3 shows a higher O2 evolution activity than WO3 and 2-propanol can be mineralized by the AgSbO3 photocatalysis under visible light irradiation.

2008-01-01

304

Light-dependent regulation of DEL1 is determined by the antagonistic action of E2Fb and E2Fc.  

Science.gov (United States)

Endoreduplication represents a cell cycle variant during which multiple rounds of DNA replication occur without subsequent chromosome separation and cytokinesis, resulting into a cellular increase of the DNA content. Although the DNA ploidy level of cells is controlled by external stimuli such as light, currently limited knowledge is available on how environmental signals regulate the endoreduplication cycle at the molecular level. Previously, we have demonstrated that the conversion from the mitotic cell cycle into an endoreduplication cycle is mediated by the atypical E2F transcription factor DEL1 that operates as a repressor of endocycle onset. Here, we identified DEL1 as a transcriptional target of the classical E2Fb and E2Fc transcription factors that antagonistically control DEL1 transcript levels through competition for a single E2F cis-acting binding site. Correspondingly with the reported opposite effect of light on the E2Fb and E2Fc ...

2011-09-01

305

Development of Efficient UV-LED Phosphor Coatings for Energy Saving Solid State Lighting  

Energy Technology Data Exchange (ETDEWEB)

The University of Georgia, in collaboration with GE Global Research, has investigated the relevant quenching mechanism of phosphor coatings used in white light devices based on UV LEDs. The final goal of the project was the design and fabrication of a high-efficacy white light UV-LED device through improved geometry and optimized phosphor coatings. At the end of the research period, which was extended to seamlessly carry over the research to a follow-up program, we have demonstrated a two-fold improvement in the conversion efficiency of a white light LED device, where the increase efficacy is due to both improved phosphor quantum efficiency and lamp geometry. Working prototypes have been displayed at DOE sponsored meetings and during the final presentation at the DOE Headquarters in Washington, DC. During the first phase of the project, a fundamental understanding of quenching processes in UV-LEDs was obtained, and the ...

2006-05-15

306

Development of Efficient UV-LED Phosphor Coatings for Energy Saving Solid State Lighting  

International Nuclear Information System (INIS)

The University of Georgia, in collaboration with GE Global Research, has investigated the relevant quenching mechanism of phosphor coatings used in white light devices based on UV LEDs. The final goal of the project was the design and fabrication of a high-efficacy white light UV-LED device through improved geometry and optimized phosphor coatings. At the end of the research period, which was extended to seamlessly carry over the research to a follow-up program, we have demonstrated a two-fold improvement in the conversion efficiency of a white light LED device, where the increase efficacy is due to both improved phosphor quantum efficiency and lamp geometry. Working prototypes have been displayed at DOE sponsored meetings and during the final presentation at the DOE Headquarters in Washington, DC. During the first phase of the project, a fundamental understanding of quenching processes in UV-LEDs was obtained, and the ...

2006-05-01

307

Determination of the emission zone in a single-layer polymer light-emitting diode through optical measurements  

Science.gov (United States)

We study the emission zone in a single-layer polymer light-emitting diode. The emission zone is found by studying the angular distribution of the electroluminescence. The emission is modeled by accounting for optical interference. We account for birefringence of the anode layer in our model. The active polymer was, however, found to be isotropic. The anode consists of a single-layer of the conducting polymer complex poly(3,4-ethylenedioxythiophene) and poly(styrene sulfonate) (PEDOT-PSS), with enhanced conductivity. As a cathode we use plain aluminum. By using only PEDOT-PSS we avoid having a thin metal layer or indium-tin-oxide as the anode in the path of the escaping light. The active material is a substituted polythiophene with excellent film forming properties. A comparison between the experimental and calculated angular distribution of light emission from a single-layered polymer light-emitting ...

2001-06-01

308

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

309

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

310

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

311

Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period  

International Nuclear Information System (INIS)

Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate the stratospheric ...

2001-01-01

312

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger ...

2009-01-01

313

Study of core collapse neutrino signals and constraints on neutrino masses from a future Galactic Supernova  

CERN Document Server

We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless double $\\beta$-decay and less precise but remarkably less ...

2005-01-01

314

Studies on the interaction of lidocaine with plasma proteins  

Energy Technology Data Exchange (ETDEWEB)

This study sought to quantitate lidocaine's interaction with alpha-1-acid glycoprotein (AAG), human serum albumin (HSA), and AAG in the presence of HSA, and to determine the extent of displacement of lidocaine from its binding site(s) by selected cardiovascular drugs (dipyridamole, disopyramide and quinidine). Since the limited experimental work reported in this area has involved the use of a single lidocaine concentration, this study involved the evaluation of a range of lidocaine concentrations. Lidocaine interaction with plasma proteins (AAG and HSA) was studied at 37/sup 0/C using an isothermal equilibrium dialysis system and /sup 14/C-lidocaine HCl. A dialysis membrane (M.W. cutoff 12,000 to 14,000) separated the two chambers of each dialysis cell. The extent of /sup 14/C-lidocaine dialysis was studied with respect to both drug and protein concentrations. Aliquots of each chamber of each of the cells were subjected to liquid scintillation counting ...

1985-01-01

315

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...

2011-06-01

316

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, respectively, and were not ...

1980-01-01

317

Photoluminescence of europium doped LiInO2 powder  

British Library Electronic Table of Contents (United Kingdom)

Abstract Lithium-indium oxide is one of the candidate materials as solid-state scintillators for solar neutrinos due to an inverse --decay of 115In to 115Sn. On the other hand, when doped with rare-earth ions such as Eu3+ or Sm3+, it becomes a promising phosphor material. In this report we present a simple solid-state procedure for preparation of LiInO2:Eu3+ powders. X-ray diffraction confirmed prod-uct in tetragonal structural form (space group: I41/amd) and no impurity phases were detected. Then, high resolution photoluminescence emission measurements were performed at room and low temperatures to find 5D0 - 7FJ. Emission kinetics from 5D0 level exhibited pure single exponential behavior with lifetime of about 1.5 ms. Maximum energy splitting of 7F1 manifold is recorded as a function of ...

2011-01-01

318

Persistence of terbufos and its metabolites in soil and maize  

International Nuclear Information System (INIS)

Degradation of "1"4C terbufos was studied under greenhouse conditions. A mixture of "1"4C labelled compound (2.48 x 10"4 Bq of O-ethyl-1- "1"4C) und unlabelled compound (0.09 g of the granule formulation Counter 10 G) was applied to pots containing 750 g of sandy loam clay Ultisol soil with 4.9% organic matter and a cation exchange capacity of 7.6. Two treatments were established, one where maize (cultivar Cristiani) was grown and the other without plants. The soil and plants were extracted at 0, 4, 8, 16, 32 and 64 days and analyzed by a liquid scintillation counter, gas chromatography-flame photometric detector (GC-FPD) and autoradiography. The total "1"4C compounds extracted on day 64 were 31 #+-# 5.6% of the radioactivity applied in the treatments with plants and 46.1 #+-# 1.1% without plants. From the autoradiography results it can be concluded that all times the compounds identified by this technique were terbufos, terbufos sulphoxide and terbufos sulphone. ...

1996-07-01

319

Optical Turbulence Measurements and Models for Mount John University Observatory  

CERN Document Server

Site measurements were collected at Mount John University Observatory in 2005 and 2007 using a purpose-built scintillation detection and ranging system. $C_n^2(h)$ profiling indicates a weak layer located at 12 - 14 km above sea level and strong low altitude turbulence extending up to 5 km. During calm weather conditions, an additional layer was detected at 6 - 8 km above sea level. $V(h)$ profiling suggests that tropopause layer velocities are nominally 12 - 30 m/s, and near-ground velocities range between 2 -- 20 m/s, dependent on weather. Little seasonal variation was detected in either $C_n^2(h)$ and $V(h)$ profiles. The average coherence length, $r_0$, was found to be $7 \\pm 1$ cm for the full profile at a wavelength of 589 nm. The average isoplanatic angle, $\\theta_0$, was $1.0 \\pm 0.1$ arcsec. The mean turbulence altitude, $\\bar{h_0}$, was found to be $2.0\\pm0.7$ km above sea level. No average in the Greenwood frequency, $f_G$, could be established due ...

2010-01-01

320

On-line video image processing system for real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...

1983-09-15

321

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be used in-situ, the ...

2004-01-01

322

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si[sup ...

1992-01-01

323

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si"6Li). ...

1991-10-01

324

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an individual committed ...

2000-05-01

325

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and ...

2010-01-01

326

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time and energy to reveal ...

2004-03-09

327

Measuring the quark contribution to the proton spin through. nu. p yields. nu. p  

Energy Technology Data Exchange (ETDEWEB)

The LSND (Liquid Scintillator Neutrino Detector) experiment will be performed at LAMPF in the next several years. The main goal of the experiment is to search for {nu}{sub {mu}}-{nu}{sub e} oscillations with high sensitivity; however, an increasingly important by-product of this search is to measure {nu}p {yields} {nu}p elastic scattering and determine the strange quark contribution, {Delta}s, to the spin of the proton. With the 800-MeV proton energy of LAMPF, neutrinos are produced from pion decay-in-flight with an average energy of about 150 MeV. This energy is sufficiently high so that the {nu}p {yields} {nu}p cross section is large and is sufficiently low so that the low Q{sup 2} approximation (Q{sup 2} {much lt} m{sub p}{sup 2}) is valid and the cross section can be expressed in a simple form dependent upon {Delta}s as the only unknown. LAMPF with its 1-mA proton intensity is, therefore, an ideal accelerator to perform this measurement. 12 refs., 7 figs., 2 ...

1991-01-01

328

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger mode the ...

2007-01-01

329

Inventory of tritium concentration of waters in the Manche department; Inventaire des concentrations en tritium des eaux du Departement de La Manche  

Energy Technology Data Exchange (ETDEWEB)

For the inventory of water tritium concentration in the Manche department, it is the complementarity that animated the work opened during year 2001. To answer to a commune sensitivity such water quality, particularly drinking water at tap, the A.C.R.O. laboratory brought its know how to make and its technical means in the area of tritium analysis and the general council brought its know how to make and its logistics means in matter of sanitary control. This collaboration has allowed to supply an indication on the tritium content of the distribution waters of thirty of the most important cities of the department. Then, it allowed to inform on the radiological situation (in relation with the tritium presence) of coast waters and principal rivers waters. More than 160 controls have been realised between the months of march 2001 and february 2002. Only the tritium under the shape of tritiated water has been measured. The measures have been made by liquid scintillation ...

2007-07-01

330

Effects of atmospheric pressure on tracking failure of organic insulating materials; Yuki zetsuen zairyo no tai tracking sei ni oyobosu kiatsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...

1995-11-20

331

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed plants. In all cases, the total radioactivity level was lower ...

2009-10-15

332

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also ...

2006-12-01

333

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative ...

2009-12-01

334

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...

2005-01-01

335

Baccharis Salicifolia development in the presence of high concentrations of uranium in the arid environment of San Marcos, Chihuahua  

International Nuclear Information System (INIS)

In humid zones and marine environments the bio indicator contaminants by trace elements are well established. However, in arid zones it is more difficult to find these tools because there is less biodiversity. The objective of this paper was to analyze the behavior of the Baccharis salicifolia plant in areas with high uranium concentration in arid zones, to determine the characteristics of tolerance and possible use as a bio monitor for the presence of such contaminants. For this project a uraniferous zone was selected in San Marcos, located northwest of the City of Chihuahua. A total of 8 sampling points of the plant and soil were located here. Each sample was divided into the root and the stem and leaves to determine the specific activity of the uranium in both parts of the plant and its sediments. The determination of the specific activities of the total uranium in the samples was obtained by liquid scintillation with alpha-beta separation. The results indicate ...

2011-02-01

336

An on-line video image processing system for real-time neutron radiography  

International Nuclear Information System (INIS)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...

1983-09-01

337

An Investigation of the Relationship Between Tritium in Groundwater and the Dendrochronology of Tritium in Trees at the Savannah River Site. Final report  

Energy Technology Data Exchange (ETDEWEB)

This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in trace-element ...

1995-03-21

338

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

339

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

340

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron BC 501 liquid ...

341

A search for. nu. sub e appearance from stopped. pi. sup + and. mu. sup + decay at LAMPF (Los Alamos Meson Physics Facility)  

Energy Technology Data Exchange (ETDEWEB)

We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} ...

1990-01-01

342

DISSIPATION AND EXTRA LIGHT IN GALACTIC NUCLEI. II. 'CUSP' ELLIPTICALS  

International Nuclear Information System (INIS)

We study the origin and properties of 'extra' or 'excess' central light in the surface brightness profiles of cusp or power-law elliptical galaxies. Dissipational mergers give rise to two-component profiles: an outer profile established by violent relaxation acting on stars already present in the progenitor galaxies prior to the final stages of the merger, and an inner stellar population comprising the extra light, formed in a compact central starburst. By combining a large set of hydrodynamical simulations with data that span a broad range of profiles at various masses, we show that observed cusp ellipticals appear consistent with the predicted 'extra light' structure, and we use our simulations to motivate a two-component description of the observations that allows us to examine how the properties and mass of this component scale with, e.g., the mass, gas content, and other properties of the galaxies. We show how to ...

2009-03-01

343

ZnO microsheet modified TiO2 nanoparticle composite films for dye-sensitized solar cells  

British Library Electronic Table of Contents (United Kingdom)

Randomly oriented ZnO microsheets were successfully self-assembled on TiO2 nanoparticle (TN) film to act as the scattering layer via a cathodic electrodeposition process. The light scattering properties of ZnO microsheets were studied by UV-Vis spectrometer in the 400?800 nm wavelength range. It was found that ZnO microsheets exhibited excellent ability to scatter the incident light for ZnO microsheet-TiO2 nanoparticle (ZT) composite films. The results showed that dye-sensitized solar cells (DSSCs) fabricated with ZT composite films showed higher short-circuit density (J sc) and conversion efficiency than TN-based DSSCs, due to the light scattering properties of ZnO microsheets.

2010-01-01

344

Solar cell  

Energy Technology Data Exchange (ETDEWEB)

For a solar cell, in order to minimize the loss of incident light, transparent glass or plastic material is used at the incident part. When a solar cell is watched from the light incident part, a silicon base material is directly observed with either block or brown color only. This invention enables a solar cell to give brighter color on the incident surface by placing a reflective film which reflects only the light of specific wavelength, without reducing the efficiency of the solar cell. This reflective film consists of multi-layered dielectric with 12 layers and alternative combination of highly refractive and less refractive substances. Highly refractive layer is Y/sub 2/O/sub 3/ with refractive index 1.74 and the less refractive layer is SiO/sub 2/ with refractive index 1.45. (5 figs)

1987-09-19

345

Photobioreactor for cultivation and real-time, in-situ measurement of O2 and CO2 exchange rates, growth dynamics, and of chlorophyll fluorescence emission of photoautotrophic microorganisms  

British Library Electronic Table of Contents (United Kingdom)

A detailed knowledge about the dynamics of phytoplanktonic photosynthesis and respiration is crucial for the determination of primary productivity in open oceans as well as for biotechnological applications. The dynamics are best studied in photobioreactors that are able to simulate natural conditions in such, that light can be modulated not only diurnally but also mimicking effects of solar elevation angle from sunrise to sunset, variable cloudiness, light modulation in refractory sun flecks due to water waves, or light intermittence due to turbulent flow in dense suspensions. In addition, high performance photobioreactors ought to be able to monitor in real time photosynthetic and respiratory activities as well as culture growth. Here, we demonstrate performance of a newly designed bench...

2009-01-01

346

PLZT spatial light modulator for a 1-D hologram memory.  

Science.gov (United States)

A 100-bit slitlike aperture array spatial light modulator has been developed using 8.8/65/35 PLZT for a high-bit-density 1-D hologram memory. The most desirable characteristics, such as distortion-free diffraction-limited Fourier transform patterns and good uniformity of displayed bit patterns over 100 bits, have been realized. The lowest SNR was 86, and rise time and fall time have been 30 microsec and 8 microsec, respectively, at 190-V halfwave voltage. One-dimensional holographic storage experiments have been successfully performed using this PLZT spatial light modulator. PMID:20216813

1980-01-01

347

Observation of Spontaneous Brillouin Cooling  

CERN Document Server

While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, a Brillouin cooling regime. Cooling is ...

2011-01-01

348

Monte Carlo simulations incorporating Mie calculations of light transport in tissue phantoms: Examination of photon sampling volumes for endoscopically compatible fiber optic probes  

Energy Technology Data Exchange (ETDEWEB)

Details of the interaction of photons with tissue phantoms are elucidated using Monte Carlo simulations. In particular, photon sampling volumes and photon pathlengths are determined for a variety of scattering and absorption parameters. The Monte Carlo simulations are specifically designed to model light delivery and collection geometries relevant to clinical applications of optical biopsy techniques. The Monte Carlo simulations assume that light is delivered and collected by two, nearly-adjacent optical fibers and take into account the numerical aperture of the fibers as well as reflectance and refraction at interfaces between different media. To determine the validity of the Monte Carlo simulations for modeling the interactions between the photons and the tissue phantom in these geometries, the simulations were compared to measurements of aqueous suspensions of polystyrene microspheres in the wavelength range 450-750 nm.

1996-04-01

349

Light amplification by S/sub 2/ molecules in the visible spectrum under supersonic cooling of a sulfur-containing gas mixture  

Energy Technology Data Exchange (ETDEWEB)

The light gain due to S/sub 2/ molecules in a supersonically cooled gas mixture is calculated. The S/sub 2/ molecules formed due to the recombination of the sulfur atoms, and the combustion gas mixture was preheated in a precombustion chamber. Optimal gas flow and nozzle parameters are found which correspond to the highest possible light gain using Cs/sub 2/-Ar and S/sub 2/-Ar gas mixtures. The steady state gas flow in the nozzle was calculated, taking into account the chemical reactions in the one-dimensional approximation. It is shown that the maximum gain values vary in the 0.0001-0.002 range for gas pressures in the precombustion chamber in the range 10-100 atm. The optimal initial relative concentration of Cs/sub 2/ molecules and S/sub 2/ molecules are given. 32 references.

1985-08-01

350

Interface-induced conversion of infrared to visible light at semiconductor interfaces  

International Nuclear Information System (INIS)

Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.

351

Injection control and thermally stimulated current in ionic polarized polymer based light emitting diode  

International Nuclear Information System (INIS)

An effective method of enhancing charge injection and electroluminescence efficiency of polymer-based light emitting diode is introduced. Spin-coated films of poly (N-vinylcarbazole) blended with electron-transport material (Bu-PBD), laser dye (Coumarin6), and the typical supporting electrolyte (tetraethylammonium perchlorate; TEAP) were examined and it was found that the injection current and luminance of the light emitting diode doped with TEAP were enhanced dramatically after heat-treatment at 80 deg. C and appropriate biasing in an external electric field of 1.5x10"8 V/m at this temperature. The thermally stimulated current (TSC) was also measured to investigate the relaxation process of ionic space charges in the films. The relaxation times of ionic polarization were found to be related to the cation size of the electrolyte. And the relaxation time becomes long enough by the use of TEAP doping.

2003-08-22

352

Enhanced inactivation of bacteria by metal-oxide nanoparticles combined with visible light irradiation  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground In recent years nano-metaloxides which easily penetrate into the cells with special interest due to their higher chemical reactivity as compared to that of similar materials in the bulk form. Of particular interest are nano-TiO2 and ZnO, which have been widely used for their bactericidal and anticancerous properties. Purpose The aim of the present study was to examine the bactericidal properties of nano-TiO2 and ZnO combined with visible light on S. aureus and S. epidermitis, known for their high prevalence in infected wounds. Study Using the technique of electron-spin resonance (ESR) coupled with spin trapping, we examined the ability of TiO2 and ZnO nanoparticle suspensions in water to produce reactive oxygen species (ROS) with and without visible light irradiation. Th...

2011-01-01

353

Contrast Sensitivity and Optical Quality of the Eye after Instillation of Timolol Maleate Gel-Forming Solution and Brinzolamide Ophthalmic Suspension  

British Library Electronic Table of Contents (United Kingdom)

Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...

2010-01-01

354

Contact lens disinfection by ultraviolet light  

Energy Technology Data Exchange (ETDEWEB)

A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.

1989-12-15

355

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 by the irradiation. From these results we can find that ...

356

Visual Arrestin 1 Contributes to Cone Photoreceptor Survival and Light Adaptation  

UK PubMed Central (United Kingdom)

Purpose.To evaluate morphologic and functional contributions of Arrestin 1 (Arr1) and Arrestin 4 (Arr4) in cone photoreceptors, the authors examined the phenotypes of visual arrestin...Full Text Available

2010-05-01

357

Visible light and risk of age-related macular degeneration.  

UK PubMed Central (United Kingdom)

Sunlight exposure has been suggested as a cause of AMD. To examine this, we collected detailed histories of ocular sun exposure in 838 watermen who work on the Chesapeake Bay. The presence and severity...Full Text Available

1990-01-01

358

Turbocharger for micro-cars; Keijidoshayo turbocharger  

Energy Technology Data Exchange (ETDEWEB)

This paper explains technologies for turbo chargers used in light cars. Light car engine turbo chargers have been given various improvements responding to needs of the market. Since ball bearings have less mechanical loss than sliding bearings, and enhances greatly the turbo efficiency, they are used in some high performance engines of light cars. While the conventional ball bearing has used high hardness bearing steel, the new standard cars started using ceramic ball. The currently used light car gasoline engines are divided into two kinds, serial three-cylinder type and serial four-cylinder type, either having merits and demerits. The new twin entry turbo developed by IHI arranges divided exhaust gas ports above and below to simplify the manifold shape, and realizes smooth flow by twisting the exhaust gas flow path inside the turbine housing. This makes the dynamic pressure of the exhaust gas more ...

2000-05-20

359

Transport of Indole-3-Acetic Acid during Gravitropism in Intact Maize Coleoptiles 1  

UK PubMed Central (United Kingdom)

We have investigated the transport of tritiated indole-3-acetic acid (IAA) in intact, red light-grown maize (Zea mays) coleoptiles during gravitropic induction and the subsequent development...Full Text Available

1990-12-01

360

The relationship of time and space  

CERN Document Server

We show that, in addition to radiation travelling at the speed of light, QED theory predicts a second type of radiation with an infinite velocity. We also show that charge, as it appears in the Dirac equation, may have a triune nature.

2004-01-01

361

The Arabidopsis ref2 Mutant Is Defective in the Gene Encoding CYP83A1 and Shows Both Phenylpropanoid and Glucosinolate Phenotypes  

UK PubMed Central (United Kingdom)

The Arabidopsis ref2 mutant was identified in a screen for plants having altered fluorescence under UV light. Characterization of the ref2 mutants showed that they...Full Text Available

2003-01-01

362

Tachyons  

International Nuclear Information System (INIS)

Arguments in favour of the possibility of the existence and the non-existence of tachyons are put forward. Some of the theoretical and experimental attempts which have either supported the view that tachyons exist or not are mentioned. In the light of evidence, available as of now, it is surmised that they may not exist and if they do, they may be neutral in charge. (K.B.).

363

Synthesis and degradation of dinoflagellate plastid-encoded psbA proteins are light-regulated, not circadian-regulated  

UK PubMed Central (United Kingdom)

In many dinoflagellate species, the plastid genome has been proposed to exist as a limited number of single-gene minicircles, and many genes normally found in the plastid genome are nuclear-encoded....Full Text Available

2005-02-22

364

Structural basis of growth-related gain and age-related loss of bone strength  

UK PubMed Central (United Kingdom)

If bone strength was the only requirement of skeleton, it could be achieved with bulk, but bone must also be light. During growth, bone modelling and remodelling optimize strength, by depositing bone...Full Text Available

2008-07-01

365

Strategies for the uses of lanthanide NMR shift probes in the determination of protein structure in solutio. Application to the EF calcium binding site of carp parvalbumin.  

UK PubMed Central (United Kingdom)

The homologous sequences observed for many calcium binding proteins such as parvalbumin, troponin C, the myosin light chains, and calmodulin has lead to the hypothesis that these proteins have homologous...Full Text Available

1980-10-01

366

Spectroscopic ellipsometry and polarimetry for materials and systems analysis at the nanometer scale: state-of-the-art, potential, and perspectives  

UK PubMed Central (United Kingdom)

This paper discusses the fundamentals, applications, potential, limitations, and future perspectives of polarized light reflection techniques for the characterization of materials and related systems...Full Text Available

2009-10-01

367

Solid-State Lighting at Sandia National Laboratory - Grand Challenge...  

Science.gov (United States)

Barbara), Arto Nurmikko (Brown U), Ed Petrow (DOE), Jim Brodrick (DOE), John Carrano (DARPA), Bob Karlicek (Gelcore), John Zolper (DARPA), and Steve Johnson (LBNL). This project...

2011-08-27

368

Shedding New Light on Early Caries Detection  

UK PubMed Central (United Kingdom)

Dental caries continues to be a common chronic disease among various population groups. Patient care can be improved with detection at the earliest stage. However, current techniques do not...Full Text Available

2008-12-01

369

SeaWiFS Postlaunch Technical Report Series  

Science.gov (United States)

tion and the Copenhagen symposium in many regards heralded the birth of modern marine bio-optics and the .... given to conducting a pigment intercomparison based on .... assignment of personnel and equipment, so the Hout Bay deployments were suspended. ...... submarine light field. Upwelling radiance is measured at ...

370

Safety Implications of High-Field MRI: Actuation of Endogenous Magnetic Iron Oxides in the Human Body  

UK PubMed Central (United Kingdom)

BackgroundMagnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla) are becoming increasingly common. In light of recent...Full Text Available

371

SN1987A: The supernova of a lifetime  

Energy Technology Data Exchange (ETDEWEB)

The current status of cosmological observations is presented; and the light curves and radiation spectra from supernova SN1987A are used in comparison between expected and observed universal nucleosynthesis and star evolution data./aip/.

1988-09-20

372

Role of Methoxypolyethylene Glycol on the Hydration, Activity, Conformation and Dynamic Properties of a Lipase in a Dry Film  

UK PubMed Central (United Kingdom)

A combined approach based on the use of ATR-FT/IR and steady-state fluorescence spectroscopy allowed to shed light on the effects of the additive methoxypolyethylene glycol (MePEG) on the hydration,...Full Text Available

2008-10-01

373

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

374

Relativistic mean field theory and applications in finite nuclei  

Energy Technology Data Exchange (ETDEWEB)

Relativistic mean field (RMF) theory is applied to modern problems of nuclear structure, such as the description of rotating bands in super-deformed nuclei or the investigation of neutron halos in light exotic nuclei. (orig.)

1997-05-01

375

Red Light-Regulated Growth 1  

UK PubMed Central (United Kingdom)

We examined the changes in the levels of indoleacetic acid (IAA), IAA esters, and a 22-kilodalton subunit auxin-binding protein (ABP1) in apical mesocotyl tissue of maize (Zea mays...Full Text Available

1991-09-01

376

Recognizing brain activities by functional near-infrared spectroscope signal analysis  

UK PubMed Central (United Kingdom)

BackgroundFunctional Near-Infrared Spectroscope (fNIRs) is one of the latest technologies which utilize light in the near-infrared range to determine brain activities. Near-infrared...Full Text Available

377

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

378

QTL analysis of measures of mouse home-cage activity using B6/MSM consomic strains  

UK PubMed Central (United Kingdom)

The activity of mice in their home cage is influenced greatly by the cycle of light and dark. In addition, home-cage activity shows remarkable time-dependent changes that result in a prominent temporal...Full Text Available

2010-10-01

379

Purification and Characterization of a Membrane-Bound Protease from Chlamydomonas reinhardtii 1  

UK PubMed Central (United Kingdom)

In Chlamydomonas reinhardtii y-1, newly synthesized chlorophyll a/b-binding apoproteins are degraded when chlorophylls are not present for assembly of stable light-harvesting...Full Text Available

1992-07-01

380

Pulmonary endothelial and bronchiolar epithelial lesions induced by 4-ipomeanol in mice.  

UK PubMed Central (United Kingdom)

The morphogenesis of pulmonary edema and bronchiolar injury induced by the toxic furan, 4-ipomeanol, was studied by combined light and transmission electron microscopy. Weanling male CD-1 mice received...Full Text Available

1985-01-01

381

Print - NASA  

Science.gov (United States)

Jul 17, 2008 ... The first version uses a red-green-blue filter; the second, an infrared-green- blue. Videos credit: Donald J. Lindler, Sigma Space Corporation/GSFC; ... The video will help us connect a varying point of planetary light ...

382

Precision tests of the electroweak interaction  

CERN Document Server

The status of the electroweak Standard Model is reviewed in the light of recent precision data and new theoretical results which have contributed to improve the predictions for precision observables, together with the remaining inherent theoretical uncertainties. Consequences for possible new physics are also discussed.

1995-01-01

383

Phytochrome-mediated Electric Potential Changes in Oat Seedlings 1  

UK PubMed Central (United Kingdom)

Brief exposures to red light induce far red-reversible changes of 5 to 10 millivolts magnitude in the upper 1 centimeter of etiolated Avena coleoptiles. The changes begin within 15...Full Text Available

1972-12-01

384

Phytochrome-controlled Hydrogen Ion Excretion by Avena Coleoptiles 1  

UK PubMed Central (United Kingdom)

A red light-induced, far red reversible stimulation of proton efflux from apical segments of etiolated Avena sativa L. cv. Victory coleoptiles was observed. The acidification...Full Text Available

1977-04-01

385

Photosynthetic Response of Seagrasses to Ultraviolet-A Radiation and the Influence of Visible Light Intensity 1  

UK PubMed Central (United Kingdom)

Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available

1982-02-01

386

Photocatalytic hydrogen production from solutions of sulfite using platinized cadmium sulfide powder  

Energy Technology Data Exchange (ETDEWEB)

Platinized cadmium sulfide powder suspended in a solution of sodium sulfite produces hydrogen efficiently by visible light. Sulfite ions are oxidized to sulfate and dithionate ions. 4 figures.

1983-09-29

387

Phosphorylation-dependent power output of transgenic flies: an integrated study.  

UK PubMed Central (United Kingdom)

We examine how the structure and function of indirect flight muscle (IFM) and the entire flight system of Drosophila melanogaster are affected by phosphorylation of the myosin regulatory light chain...Full Text Available

1997-12-01

388

Penny Battery  

Science.gov (United States)

In this activity, learners light an LED with five cents. Learners use two different metals and some sour, salty water to create a cheap battery. Learners also have the option of checking the voltage of their battery if a voltmeter is available.

389

Partitioning and transport of the translocates mannitol and sucrose in the light and dark in celery (Apium Graveolens L. )  

Energy Technology Data Exchange (ETDEWEB)

Sucrose and mannitol are major photosynthetic products and translocates in celery. Assimilate partitioning and transport were studied by pulse-labeling leaves with /sup 14/CO/sub 2/ followed by different length chases in ambient air. After a 2 h chase in the light there was more /sup 14/C in sucrose than mannitol in source leaves and their petioles. In contrast after a 2 h dark chase leaves contained more /sup 14/C in mannitol than sucrose but petioles had more /sup 14/C in sucrose than mannitol. After a 15 h chase (6 h light; 9 h dark) labeled sucrose was higher in source petiole vascular bundles than in adjacent parenchyma tissue but label in glucose and fructose was higher in the parenchyma tissue. After the 15 h chase most of the /sup 14/C remaining in developing sink leaves and their petioles was in mannitol. Although in the light mannitol:sucrose ratios are the same in leaf and petiole tissues, in the dark sucrose is ...

1987-04-01

390

Partial Characterization of Cadmium-Binding Protein from Roots of Tomato 1  

UK PubMed Central (United Kingdom)

Cd-binding protein was extracted from tomato roots and purified on QAE-Sephadex A-25 and on Sephadex G-75 in 1 molar KCl buffer. The protein preparation was light brown and contained predominantly Cd...Full Text Available

1986-07-01

391

PAS Domain Residues Involved in Signal Transduction by the Aer Redox Sensor of Escherichia coli  

UK PubMed Central (United Kingdom)

SummaryPAS domains sense oxygen, redox potential and light, and are implicated in behavior, circadian rhythmicity, development and metabolic regulation. Although PAS domains are...Full Text Available

2000-05-01

392

Nyctohemeral Rhythm in Melatonin Response to Isoproterenol In vitro: Comparison of Rats and Syrian Hamsters,  

Science.gov (United States)

The in vitro response of melatonin synthesis was assessed by incubation of individual whole pineal glands for 4 hr without or with different concentrations of isoproterenol in the medium. Pineals were taken either at the end of the 14-hr light phase (day)...

1987-01-01

393

Nanoparticles and their tailoring with laser light  

Energy Technology Data Exchange (ETDEWEB)

Monodisperse noble metal nanoparticles are of tremendous interest for numerous applications, such as surface-enhanced Raman spectroscopy, catalysis or biosensing. However, preparation of monodisperse metal nanoparticles is still a challenging task, because typical preparation methods yield nanoparticle ensembles with broad shape and/or size distributions. To overcome this drawback, tailoring of metal nanoparticles with laser light has been developed, which is based on the pronounced shape- and size-dependent optical properties of metal nanoparticles. I will demonstrate that nanoparticle tailoring with ns-pulsed laser light is a suitable method to prepare nanoparticle ensembles with a narrow shape and/or size distribution. While irradiation with ns-pulsed laser light during nanoparticle growth permits a precise shape tailoring, post-grown irradiation allows a size tailoring. For example, the initial broad Gaussian size ...

2009-07-15

394

Morphology and Ultrastructure of Maternal Seed Tissues of Soybean in Relation to the Import of Photosynthate  

UK PubMed Central (United Kingdom)

Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available

1981-05-01

395

Method of restoring degraded solar cells  

Energy Technology Data Exchange (ETDEWEB)

Amorphous silicon solar cells have been shown to have efficiencies which degrade as a result of long exposure to light. Annealing such cells in air at a temperature of about 200.degree. C. for at least 30 minutes restores their efficiency.

1983-01-01

396

Memorandum : No. 013-M : 01/20/95:More than 200 soldiers ...  

Science.gov (United States)

... has rotated active duty battalions from its light infantry divisions. ... the departure should contact Major Jim Hinnant, 82nd Airborne Division PAO, at ...

397

Melanopsin-expressing retinal ganglion-cell photoreceptors: cellular diversity and role in pattern vision  

UK PubMed Central (United Kingdom)

Using the photopigment melanopsin, intrinsically photosensitive retinal ganglion cells (ipRGCs) respond directly to light to drive circadian clock resetting and pupillary constriction. We now...Full Text Available

2010-07-15

398

Meet the NASA Scientists and Engineers Andrea ... - Aura - NASA  

Science.gov (United States)

Equipped with terahertz sensors, the Aura mission will see far more ... We introduce you to a few amazing individuals, all sharing the dubious title of rocket scientist . And a ..... similar thing happens with incoming light. Astronomers call it the ...

399

Mammalian target of rapamycin signaling modulates photic entrainment of the suprachiasmatic circadian clock  

UK PubMed Central (United Kingdom)

Inducible gene expression appears to be an essential event that couples light to entrainment of the master mammalian circadian clock located in the suprachiasmatic nucleus (SCN) of the hypothalamus....Full Text Available

2010-05-05

400

Light-induced Adhesion of Spirogyra Cells to Glass 1  

UK PubMed Central (United Kingdom)

Adhesion of Spirogyra (tentatively, Spirogyra fluviatilis) cells to glass is described. The cells of an algal filament can adhere to a substrate only when they are...Full Text Available

1977-04-01

401

Light-Dependent Regulation of Cyanobacterial Phytochrome Expression  

UK PubMed Central (United Kingdom)

A histidine kinase protein (Cph1) with sequence homology and spectral characteristics very similar to those of the plant phytochrome has been recently identified in the cyanobacterium Synechocystis...Full Text Available

2000-01-01

402

Light and Dark Controls of Nitrate Reduction in Wheat (Triticum aestivum L.) Protoplasts 1  

UK PubMed Central (United Kingdom)

Protoplasts were isolated from the leaves of nitrate-cultured wheat (Triticum aestivum L. var. Frederick) seedlings. When incubated in the dark, protoplasts accumulated nitrite under...Full Text Available

1982-02-01

403

LED Arrays as Cost Effective and Efficient Light Sources for Widefield Microscopy  

UK PubMed Central (United Kingdom)

New developments in fluorophores as well as in detection methods have fueled the rapid growth of optical imaging in the life sciences. Commercial widefield microscopes generally use arc lamps, excitation/emission...Full Text Available

404

LATEST LASER AND LIGHT-BASED ADVANCES FOR ETHNIC SKIN REJUVENATION  

UK PubMed Central (United Kingdom)

Background:Advances in nonablative skin rejuvenation technologies have sparked a renewed interest in the cosmetic treatment of aging skin. More options exist now than ever...Full Text Available

2008-01-01

405

Isolation and identification of a cobamide coenzyme from the tapeworm Spirometra mansonoides.  

Science.gov (United States)

A light-sensitive vitamin B12 derivative has been extracted from the adult cestode, Spirometra mansonoides. This corrinoid was identified as the cobamide coenzyme, adenosylcobalamin, by its chromatographic, chemical, and spectral properties. PMID:1003284

1976-12-01

406

Intra- and extracellular calcium modulates stereocilia stiffness on chick cochlear hair cells.  

UK PubMed Central (United Kingdom)

Segments of the chick basilar papilla were isolated and maintained in culture medium. The sensory hair bundle of individual hair cells was observed with light microscopy and stimulated with a water...Full Text Available

1994-02-01

407

Increased degradation of MYPT1 contributes to the development of tolerance to nitric oxide in porcine pulmonary artery  

UK PubMed Central (United Kingdom)

Myosin phosphatase target subunit 1 (MYPT1) is the regulatory subunit of myosin light chain phosphatase (MLCP). It plays a critical role in vasodilatation induced by cGMP-elevating agents such as nitric...Full Text Available

2010-07-01

408

In vitro and in vivo estrogenicity of UV screens.  

UK PubMed Central (United Kingdom)

Ultraviolet (UV) screens are increasingly used as a result of growing concern about UV radiation and skin cancer; they are also added to cosmetics and other products for light stability. Recent data...Full Text Available

2001-03-01

409

Impossibility of a scalar tachyon  

Energy Technology Data Exchange (ETDEWEB)

It is the purpose of this paper to prove that a preferred space direction is coupled with each tachyon and, consequently, scalar tachyons, are impossible in principle. Even the notion of a scalar faster-than-light particle cannot be defined in a relativistically invariant way.

1982-06-01

410

How do planetary nebulae evolve  

Energy Technology Data Exchange (ETDEWEB)

This article throws light on an only recently understood but important development of star evolution - that of the occurrence of planetary nebulae. The process is controlled by thermonuclear physics and gravitation and now and again greatly influenced by mass loss.

1982-01-01

411

Home Construction by a Community College.  

Science.gov (United States)

Describes the light construction curriculum offered at Carteret Technical College, NC, in terms of course offerings, program finances, problems, and the establishment of tax-exempt endowment corporation through which the program was funded. Concludes with suggestions for organizing a construction program. (AYC)

1979-12-01

412

Holographic and Quark-Hadron Duality for Form Factors  

Energy Technology Data Exchange (ETDEWEB)

We study the large-Q{sup 2} behavior of the meson form factor F{sub M} (Q{sup 2}) constructed using the holographic light-front wave functions.

2006-05-15

413

High-energy reaction cross sections of light nuclei  

Energy Technology Data Exchange (ETDEWEB)

The high-energy reaction cross sections of Li and Be isotopes are calculated using a simplified Glauber model and densities constrained by the empirical binding energies. We find excellent agreement with experiment, reproducing the large increase for the most neutron-rich nuclei.

1989-03-01

414

Glossary - Helmholtz-Centre for Environmental Research - UFZ - Research for the environment  

Wastenet

... Contrary to this definition, abiotic environmental factors are those in which no organisms participate - e.g. the geological underground, light, temperature and heat. Biotope The biotope is an area of uniform environmental conditions providing living place for a specific assemblage of plants and animals....

415

From spectral information to animal colour vision: experiments and concepts  

UK PubMed Central (United Kingdom)

Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact...Full Text Available

2010-06-07

416

Formation and fate of gaseous and particulate mutagens and carcinogens in real and simulated atmospheres.  

UK PubMed Central (United Kingdom)

The growing use of coal for heating and electric power generation and diesel engines in light duty motor vehicles will increase not only the existing atmospheric concentrations of criteria pollutants...Full Text Available

1983-01-01

417

Evidence for the Regulation of Phytochrome-mediated Processes in Bean Roots by the Neurohumor, Acetylcholine 1  

UK PubMed Central (United Kingdom)

Using pharmacological and chromatographic techniques, it was shown that acetylcholine was present in all organs of both light- and dark-grown mung bean seedings (Phaseolus aureus)....Full Text Available

1970-12-01

418

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

419

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

420

Effect of Temperature, Light and Salinity on Seed Germination and Radicle Growth of the Geographically Widespread Halophyte Shrub Halocnemum strobilaceum  

UK PubMed Central (United Kingdom)

Background and AimsThe small leafy succulent shrub Halocnemum strobilaceum occurs in saline habitats from northern Africa and Mediterranean Europe to western Asia,...Full Text Available

2008-01-01

421

Developmental and Light Regulation of Desacetoxyvindoline 4-Hydroxylase in Catharanthus roseus (L.) G. Don.1  

UK PubMed Central (United Kingdom)

The expression of desacetoxyvindoline 4-hydroxylase (D4H), which catalyzes the second to the last reaction in vindoline biosynthesis in Catharanthus roseus, appears to be under complex,...Full Text Available

1998-08-01

422

Designer himself throws light upon high-temperature reactor  

Energy Technology Data Exchange (ETDEWEB)

THe high-temperature reactor is one of the alternatives for the now predominantly employed water-reactors. In a recently published book designer Rudolf Schulten outlines his concept. In this article the book is reviewed. (author). 1 ref.; 1 fig.

1990-04-01

423

Designer himself throws light upon high-temperature reactor  

International Nuclear Information System (INIS)

THe high-temperature reactor is one of the alternatives for the now predominantly employed water-reactors. In a recently published book designer Rudolf Schulten outlines his concept. In this article the book is reviewed. (author). 1 ref.; 1 fig.

424

Dependency of Nitrate Reduction on Soluble Carbohydrates in Primary Leaves of Barley under Aerobic Conditions 1  

UK PubMed Central (United Kingdom)

Nitrate reduction was studied as a function of carbohydrate concentration in detached primary leaves of barley (Hordeum vulgare L. cv Numar) seedlings under aerobic conditions in light...Full Text Available

1984-07-01

425

Cryptococcus neoformans Mediator Protein Ssn8 Negatively Regulates Diverse Physiological Processes and Is Required for Virulence  

UK PubMed Central (United Kingdom)

Cryptococcus neoformans is a ubiquitously distributed human pathogen. It is also a model system for studying fungal virulence, physiology and differentiation. Light is known to inhibit...Full Text Available

426

Cross sections and spin asymmetries in vector meson leptoproduction  

CERN Document Server

Light vector meson leptoproduction is analyzed on the basis of the generalized parton distributions. Our results on the cross section and spin effects are in good agrement with experiment at HERA, COMPASS and HERMES energies. Predictions for $A_{UT}$ asymmetry for various reactions are presented.

2009-01-01

427

Comparison of the Photosynthetic Characteristics of Three Submersed Aquatic Plants 1  

UK PubMed Central (United Kingdom)

Light- and CO2-saturated photosynthetic rates of the submersed aquatic plants Hydrilla verticillata, Ceratophyllum demersum, and Myriophyllum spicatum were...Full Text Available

1976-12-01

428

Cogan's microcystic dystrophy of the cornea: ultrastructure and photomicroscopy.  

UK PubMed Central (United Kingdom)

Corneal biopsy specimens from 3 patients with Cogan's microcystic corneal dystrophy were examined by light and electron microscopy. Specimens were taken from corneas showing microcysts, geographic or...Full Text Available

1978-12-01

429

Characterization of Photosystem II Activity and Heterogeneity during the Cell Cycle of the Green Alga Scenedesmus quadricauda1  

UK PubMed Central (United Kingdom)

The photosynthetic activity of the green alga Scenedesmus quadricauda was investigated during synchronous growth in light/dark cycles. The rate of O2 evolution increased...Full Text Available

1999-06-01

430

Carmanah Technologies Corporation 2004 annual report  

International Nuclear Information System (INIS)

British Columbia-based Carmanah Technologies is a world leader in the design, manufacture and supply of patented solar-powered light emitting diode (LED) lighting solutions. As a leading alternative energy manufacturer, it was the first company to integrate LEDs with solar chargers and battery power storage. Carmanah products have high-end assembly, minimal size, maximized performance and field-proven reliability. The products have been used in public transit applications, roadway lighting, and for general aviation lighting solutions. In 2004, their products saved the equivalent of 6,705 metric tonnes of carbon dioxide. This annual report includes information on the company's net earnings and investor profiles. The company has large markets for its products with little competition. It has a strong management team and its funding places it in a position to capitalize on current and emerging technologies. ...

2005-01-01

431

Cardiac Myosin Is a Substrate for Zipper-interacting Protein Kinase (ZIPK)*  

UK PubMed Central (United Kingdom)

Zipper-interacting protein kinase (ZIPK) is a member of the death-associated protein kinase family associated with apoptosis in nonmuscle cells where it phosphorylates myosin regulatory light chain...Full Text Available

2010-02-19

432

Carbon Partitioning in Eelgrass (Regulation by Photosynthesis and the Response to Daily Light-Dark Cycles).  

UK PubMed Central (United Kingdom)

Diel variations in rates of C export, sucrose-phosphate synthase (SPS) and sucrose synthase (SS) activity, and C reserves were investigated in Zostera marina L. (eelgrass) to elucidate the environmental...Full Text Available

1995-08-01

433

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

434

Big bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The concordance of standard big bang nucleosynthesis theory and the related observations of the light element isotopes (including some new higher {sup 4}He abundances) will be reviewed. Implications of BBN on chemical evolution, dark matter and constraints on particle properties will be discussed.

1999-01-01

435

Auxin Transport Is Required for Hypocotyl Elongation in Light-Grown but Not Dark-Grown Arabidopsis1  

UK PubMed Central (United Kingdom)

Many auxin responses are dependent on redistribution and/or polar transport of indoleacetic acid. Polar transport of auxin can be inhibited through the application of phytotropins such as 1-naphthylphthalamic...Full Text Available

1998-02-01

436

Autosolvent effect of bitumen in thermal cracking; Netsubunkai hanno ni okeru bitumen no jiko yobai koka  

Energy Technology Data Exchange (ETDEWEB)

Tar sand bitumen is petroleum-based ultra-heavy oil, and has a great amount of reserve like coal. However, there are still a lot of problems for its highly effective utilization. This paper discusses whether the light components in bitumen show independent behavior during the thermal cracking of heavy components, or not. Solvent effect and reaction mechanism during the thermal cracking are also derived from the change of their chemical structures. Athabasca tar sand bitumen was separated into light and heavy fractions by vacuum distillation based on D-1660 of ASTM. Mixtures of the both fractions at various ratios were used as samples. Negative effect of the light fraction on cracking of the heavy fraction was observed with dealkylation and paraffin formation Polymerization of the dealkylated light fraction to the heavy fraction was suggested due to lack of hydrogen in the thermal cracking under nitrogen ...

1996-10-28

437

Analyzing the Light Energy Distribution in the Photosynthetic Apparatus of C4 Plants Using Highly Purified Mesophyll and Bundle-Sheath Thylakoids.  

UK PubMed Central (United Kingdom)

The chlorophyll fluorescence characteristics of mesophyll and bundle-sheath thylakoids from plant species with the C4 dicarboxylic acid pathway of photosynthesis were investigated using flow cytometry....Full Text Available

1996-11-01

438

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

439

Affinity maturation of human botulinum neurotoxin antibodies by light chain shuffling via yeast mating  

UK PubMed Central (United Kingdom)

Botulism is caused by the botulinum neurotoxins (BoNTs), the most poisonous substance known. Because of the high potency of BoNT, development of diagnostic and therapeutic antibodies for botulism requires...Full Text Available

2010-04-01

440

APOD: 2003 September 25 - Logarithmic Spirals Isabel and M51  

Science.gov (United States)

much in common. For starters, Isabel was hundreds of miles across, while M51 (the Whirlpool Galaxy) spans about 50,000 light-years making them vastly dissimilar in scale, not...

2011-10-07

441

A study on the fabrication of lightweight aggregates using red mud, the by-product from Al{sub 2}O{sub 3} industry  

Energy Technology Data Exchange (ETDEWEB)

Red mud, the by-product of alumina fabricating industry by the Bayer process, was investigated to produce light-weight aggregates for structural concrete. Owing to very high concentration of Fe{sub 2}O{sub 3} in the red mud, no light-weight aggregates could be sintered from the red mud alone. Thus, red mud being mixed with sewage sludge that is in its chemical composition very similar to the clay mineral, very light-weight aggregates with the apparent density smaller than 1.0 g/cm{sup 3} was able to be fired at 1,200 deg. C, by the bloating effect. For this purpose, the mixing ratio of red mud to sewage sludge must be held less than a unity. On the other hand, a mixture containing more red mud than sewage sludge required the addition of, for instance, limestone in 20-30 percent, so that medium-light weight aggregates of the apparent density ranging from 1.4 to 1.9 g/cm{sup 3} were prepared. The suitable ...

1998-01-01

442

A new gene (alkB) of Escherichia coli that controls sensitivity to methyl methane sulfonate.  

UK PubMed Central (United Kingdom)

Seven mutants of Escherichia coli were isolated that are sensitive to methyl methane sulfonate but not to UV light. They exhibited decreased host cell reactivation capacity for methyl methane sulfonate-treated...Full Text Available

1983-03-01

443

49 CFR 221.5 - Definitions.  

Science.gov (United States)

...Colormetric System, which lie within the region bounded by the spectrum locus and lines defined by the following equations: X...intensity of a light in candela as defined by the Illuminating Engineering Society's Guide for Calculating the Effective...

2010-10-01

444

The 8{pi}LP Project: A 4{pi} light charged particle detection array at LNL  

Energy Technology Data Exchange (ETDEWEB)

A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.

1996-12-31

445

Study of emission of Cerenkov radiation by tachyons  

International Nuclear Information System (INIS)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).

446

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

447

Results from the photoemission spectroscopy beamline 2B1 at Pohang Light Source  

Energy Technology Data Exchange (ETDEWEB)

The results of photoemission spectroscopy using molybdenum and tantalum samples have been obtained from the new beamline 2B1 at Pohang Light Source. Beamline 2B1 is based on a spherical grating monochromator (SGM) which is equipped with five gratings. The photon energy range from 184 to 1100 eV was covered in this work using two gratings (Gratings 4 and 5). The photon energy resolution has been deduced from Ta Fermi-level spectra and 3d spectra of Mo.

1999-06-01

448

Relativistic mean field study of light nuclei  

International Nuclear Information System (INIS)

Bulk properties such as the binding energies, r.m.s. radii and deformation parameters are calculated for the light (Z=2-8) even-mass nuclei using deformed relativistic mean-field theory. A comparison between L1, NL1 and NL2 parameter sets are given. The effects of pairing for open-shell nuclei have been investigated. The calculation is extended to nuclei near the proton- and neutron-drip line. Reasonable agreement with experiment is achieved for NL1 and NL2 parameter sets. (orig.).

449

Regeneration behavior of light-duty catalytic trap oxidizer systems  

Science.gov (United States)

A catalytic trap oxidizer based on a radial flow metal mesh filter was developed for use as an after treatment device on light-duty diesel vehicles. A complete system for assisted regeneration was devised to enable this unit to operate without blocking during all normal driving modes. The integration of the catalyzed trap and regeneration system with the vehicle to provide a practical system for the reduction of diesel particulate emissions is discussed. To date, many prototype catalytic trap and regeneration system installations have been completed on various test vehicles, both naturally aspirated and turbocharged. The operational conditions and test results from a selection of these studies are presented.

1984-01-01

450

Practical measurement of diffusion constants in sintered zirconias by using a light-scattering method  

Energy Technology Data Exchange (ETDEWEB)

A practical method to determine the ionic diffusion coefficient and activation energy by using quasielastic light scattering (QELS) is presented. It is shown that a temperature dependence curve of the QELS intensity at a fixed frequency can be well fitted by Jonscher's formula and that the diffusion parameters can be obtained from this curve fitting. This method is successfully applied not only to crystals with high optical quality, as reported earlier, but also to opaque ceramics, which are more important than the crystals from a practical point of view. The composition dependence of the ionic diffusion coefficient is studied in sintered YbSZ to show the usefulness of this method.

1991-03-01

451

Multi-nucleon transfer reactions and the formation of light charged particles in the system sup(nat)Ag + /sup 40/Ar(285MeV)  

Energy Technology Data Exchange (ETDEWEB)

In the reaction sup(nat)Ag + /sup 40/Ar (285 MeV) there have been measured the energy spectra of the isotopes of elements from H to Cl at an emission angle of 40/sup 0/, the energy spectra and angular distributions of /sup 1/H, /sup 2/H, /sup 3/H, and /sup 4/He, and the angular distributions of Li, Be, B, and C. The contribution from multinucleon transfer reactions to the formation of light charged particles is discussed.

1981-11-01

452

Linac Coherent Light Source (LCLS) Bunch-Length Monitor using Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. One of the most critical diagnostic devices is the bunch length monitor (BLM), which is to be installed right after each compressor utilizing coherent radiation from the last bending magnet. We describe the components and the optical layout of such a BLM. Based on the setup geometry, we discuss some issues about the coherent radiation signal.

2007-03-21

453

Light elements in massive single and binary stars  

CERN Document Server

We highlight the role of the light elements (Li, Be, B) in the evolution of massive single and binary stars, which is largely restricted to a diagnostic value, and foremost so for the element boron. However, we show that the boron surface abundance in massive early type stars contains key information about their foregoing evolution which is not obtainable otherwise. In particular, it allows to constrain internal mixing processes and potential previous mass transfer event for binary stars (even if the companion has disappeared). It may also help solving the mystery of the slowly rotating nitrogen-rich massive main sequence stars.

2010-01-01

454

Light dark matter in leptophobic Z' models  

CERN Document Server

Recent experimental results in direct dark matter detection may be interpreted in terms of a dark matter particle of mass around 10 GeV/c^2. We show that the required scenario can be realized with a new dark matter particle charged under an extra abelian gauge boson Z' that couples to quarks but not leptons. This is possible provided the Z' gauge boson is very light, around 10-20 GeV/c^2 in mass, and the gauge coupling constant is small, alpha' ~ 10^(-5). Such scenarios are not constrained by accelerator data.

2011-01-01

455

High efficiency planar MCLEDs  

Energy Technology Data Exchange (ETDEWEB)

The physics of microcavities have been a subject of intense study over the past 25 years. This work stimulated a large body of experimental and theoretical work on the optimization of the light extraction properties of light-emitting diodes. Not only has this led to the current high efficiency microcavity LEDs but also to the high brightness LEDs based on other approaches, which are presently available on the market. An overview of the state of the art of planar semiconductor microcavity LEDs will be presented. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2005-09-01

456

Focusing atomic beams by the dissipative radiation-pressure force of laser light  

Science.gov (United States)

An experimental realization of the focusing of an atomic beam by a spontaneous radiation pressure force is reported. A simple light field configuration for focusing an atomic beam is described which is formed by four divergent Gaussian laser beams propagating along the + or - x and + or - y directions of a Cartesian coordinate system. An experimental arrangement for the laser focusing is shown, and the experimental procedure is described. The resulting atomic beam profiles are shown and discussed. It is concluded that the experiments open up the possibility of gaining control over such parameters of atomic beams as their density and divergence. 7 references.

1986-02-01

457

Faster-than-light particles: a review of tachyon characteristics. Interim report  

Energy Technology Data Exchange (ETDEWEB)

This report documents an analytical prediction of some of the characteristics which presently undiscovered faster-than-light sub-atomic particles (called tachyons) must possess if they are to exist without violating the Theory of Special Relativity. A brief review of necessary concepts from the Special Theory is included so that the reader might more readily understand the reasoning as it is developed. Necessary, but not all, characteristics of tachyons are then identified and presented. Finally, an interesting potential relationship between tachyons and anti-gravity is discussed.

1980-10-01

458

Experimental generation of non-Kolmogorov turbulence using a liquid crystal spatial light modulator  

Science.gov (United States)

Several experiments showed that the classical Kolmogorov power spectral density of the refractive-index sometimes does not properly describe the statistics of the atmosphere. In this paper we show an experimental testbed able to generate non-classical Kolmogorov turbulence by using a liquid crystal spatial light modulator. The testbed is used at Naval Postgraduate School for laboratory investigation of laser beam propagation in maritime environment where a power law different from classical Kolmogorov, 11/ 3, could be present. Applications of this testbed are ship to-ship free space optical communication, imaging and high energy laser weapons.

2011-09-01

459

Emission of light charged particles accompanying uranium fission induced by 153-MeV protons  

Energy Technology Data Exchange (ETDEWEB)

The emission of light charged particles from heavy fragments of uranium fission induced by 153-MeV protons is studied. The probability of their emission is 2.7 x 10{sup - 2} per fission event. It is found that these particles affect the distribution of angles of fragment divergence and the angular distribution of heavy fragments with respect to the primary-proton beam. Experimental results suggest that the preequilibrium emission of particles is correlated with fission. Two mechanisms of interaction between 153-MeV protons and uranium nuclei are considered. 13 refs., 10 figs., 1 tab.

1995-12-01

460

Einstein and relativity soon out of date? Neutrinos: faster than light; Einstein et la relativite bientot depasses? Neutrinos: plus vite que la lumiere  

Energy Technology Data Exchange (ETDEWEB)

Two thirds of the neutrinos produced in the sun are not detected. In the last decade several experiments have allowed to give a limit to the neutrino mass and in some cases a negative value of the square of the mass was proposed. A negative value is inconsistent theoretically except in the case of tachyons which are particles allowed to travel faster than light. Consider neutrinos as tachyons could be a solution to find the answers to some of the riddles set by neutrinos. (A.C.)

1997-10-01

461

Decaying into the Hidden Sector  

CERN Document Server

The existence of light hidden sectors is an exciting possibility that may be tested in the near future. If DM is allowed to decay into such a hidden sector through GUT suppressed operators, it can accommodate the recent cosmic ray observations without over-producing antiprotons or interfering with the attractive features of the thermal WIMP. Models of this kind are simple to construct, generic and evade all astrophysical bounds. We provide tools for constructing such models and present several distinct examples. The light hidden spectrum and DM couplings can be probed in the near future, by measuring astrophysical photon and neutrino fluxes. These indirect signatures are complimentary to the direct production signals, such as lepton jets, predicted by these models.

2009-01-01

462

Closed string tachyons and their implications for non-supersymmetric strings  

Energy Technology Data Exchange (ETDEWEB)

Closed string tachyons have long been somewhat mysterious. We note that there is often a regime in the classical moduli space in which one can systematically compute the effective action for such fields. In this regime, the tachyon is light, and cannot be integrated out. Instead, one must consider the combined dynamics of gravitons, moduli, tachyons and other light fields. We compute the action and find that the quartic term for the tachyon is positive in the field definition where the tachyon has no derivative coupling to the radion. We study the evolution of isotropic, homogeneous configurations and find that typically the system is driven to regions where the calculation is no longer under control. (author)

2004-07-01

463

Biopsy examination during the course of radiotherapy. Progress report. [DNA content of tumor cells in biopsy samples determined by microfluorometric or multiangle light-scatter spectrometry  

Science.gov (United States)

Studies begun during the first year of this project on biopsies from spontaneous tumors in dogs and from human patients undergoing radiotherapy treatment were continued. The results indicate that significant fractions of the spontaneous tumors in dogs and cervical carcinomas in patients undergoing radiotherapy have a DNA content higher than normal diploid cells. The higher DNA content in tumor cells permits distinguishing them from normal cells in the biopsy material with the aid of flow microfluorometric (FMF) instrumentation or multiangle light-scatter spectrometry.

1977-12-01

464

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

465

Are classical tachyons slower-than-light quantum particles  

Energy Technology Data Exchange (ETDEWEB)

After having studied the shape that a tachyon T (e.g., intrinsically spherical) would take up, we show in an explicit example that the characteristics of classical tachyons are similar to those of the ordinary (slower-than-light) quantum particles. In particular, a realistic tachyon is associated with a ''phase speed'' V(V/sup 2/>c/sup 2/), but with a ''group speed'' upsilon=c/sup 2//V (upsilon/sup 2/

1983-07-02

466

Application of light microscopy to direct coal liquefaction research  

Energy Technology Data Exchange (ETDEWEB)

Light microscopy was used to analyze the effects of added catalyst at different conditions (temperature and reaction times) in liquefaction testing of a low pyritic sulfur bituminous coal. Quantitative changes in vitrinite/vitroplast reflectance of coal and liquefaction residues were shown to be useful markers in analyzing and understanding the role of catalyst during the initial stage of coal particle hydrogenation. Lower reflectance values corresponded to increased conversions up to about the 60 min and 375{degrees}C experimental conditions. Microscopical observation of liquefaction residues also revealed the presence of `wall scales` of varying width.

1998-01-01

467

Analysis of hydrogen vehicles with cryogenic high pressure storage  

Energy Technology Data Exchange (ETDEWEB)

Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LIQ) or ambient-temperature compressed hydrogen (CH2). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

1998-06-19

468

Spin-s tachyons and the propagation of tachyon waves. Part B  

International Nuclear Information System (INIS)

The propagation of bradyon and tachyon wave functions can be compared by considering them as cases of normal and anomalous dispersion and using the ideas of Brillouin which where developed in order to describe the propagation of light in a transparent medium near an adsorption line. It is found that if a wave packet, or pulse, is formed using a superposition of waves moving only in the positive x direction, including both positive energies, it will propagate superluminally for both bradyons and tachyons. If non-physical states, imaginary moments and energies, are included in the superposition, both types of waves will propagate subluminally and remain within the light cone. This last result has also been obtained by Fox, Kuper and Lipson and Strnad and Kodre for tachyons when they included imaginary energies in their superposition. However, these approaches allow the tachyon to be localizable in space and can lead to divergences in the wave ...

469

Contribution of calcium ions and hydrogen ions to the signal transduction chain in phytochrome-mediated spore germination. [Onoclea sensibilis L  

Energy Technology Data Exchange (ETDEWEB)

Red light stimulates germination in the spores of Onoclea sensibilis L. Phytochrome is confirmed to be the photoreceptor pigment in the germination response by demonstrating red-far-red photoreversibility. External Ca/sup 2 +/ is required for this response with a threshold at a submicromolar concentration. Red light stimulates an increase in the total concentration of intracellular calcium in the spores as determined by atomic absorption spectroscopy. Subsequent exposure to far-red light inhibits the red light-induced increase in intracellular calcium. The majority of the increase occurs 5 minutes after the onset of irradiation. The calcium-antagonist, La/sup 3 +/ inhibits both germination and the red light-induced increase in intracellular calcium. Using /sup 31/P-nuclear magnetic resonance spectroscopy, the author tested the hypothesis that a sustained increase in intracellular pH ...

1985-01-01

470

ADAPTIVE FULL-SPECTRUM SOLAR ENERGY SYSTEMS CROSS-CUTTING R&D ON ADAPTIVE FULL-SPECTRUM SOLAR ENERGY SYSTEMS FOR MORE EFFICIENT AND AFFORDABLE USE OF SOLAR ENERGY IN BUILDINGS AND HYBRID PHOTOBIOREACTORS  

Energy Technology Data Exchange (ETDEWEB)

This RD&D project is a three year team effort to develop a hybrid solar lighting (HSL) system that transports daylight from a paraboloidal dish concentrator to a luminaire via a bundle of small core or a large core polymer fiber optics. The luminaire can be a device to distribute sunlight into a space for the production of algae or it can be a device that is a combination of daylighting and electric lighting for space/task lighting. In this project, the sunlight is collected using a one-meter paraboloidal concentrator dish with two-axis tracking. For the second generation (alpha) system, the secondary mirror is an ellipsoidal mirror that directs the visible light into a bundle of small-core fibers. The IR spectrum is filtered out to minimize unnecessary heating at the fiber entrance region. This report describes the following investigations of various aspects of the system. Taken as a whole, ...

2004-08-01

471

Unraveling photosystems. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report highlights four main points. (1) A residue substitution in phosphoribulokinase of Synechocystis PCC 6803 renders the mutant light-sensitive. The authors isolated a light-sensitive mutant (BRLS) of the photosynthetic cyanobacterium Synechocystis 6803 that does not survive exposure to bright light; 70% of BRLS cells die upon exposure to light of > 3000 lux for 2 hr. (2) Excitation energy transfer from phycocyanin to chlorophyll in an apcA-defective mutant of Synechocystis sp. PCC 6803. A greenish mutant of the normally bule-green cyanobacterium Synechocystis sp. PC 6803, designated UV6p, was isolated and characterized. UV6p possesses functional photosystems I and II but lacks normal light harvesting phycobilisomes because allophycocyanin is absent and core-specific linker proteins are almost entirely absent. (3) Deletion of the psbG1 gene of the cyanobacterium ...

1997-09-01

472

U.V. repair in deep-sea bacteria  

International Nuclear Information System (INIS)

Exposure of cells to light of less than 320 nanometers wavelengths may lead to lethal lesions and perhaps carcinogenesis. Many organisms have evolved mechanisms to repair U.V. light-induced damage. Organisms such as deep-sea bacteria are presumably never exposed to U.V. light and perhaps occasionally to visible from bioluminescence. Thus, the repair of U.V. damage in deep-sea bacterial DNA might be inefficient and repair by photoreactivation unlikely. The bacteria utilized in this investigation are temperature sensitive and barophilic. Four deep-sea isolates were chosen for this study: PE-36 from 3584 m, CNPT-3 from 5782 m, HS-34 from 5682 m, and MT-41 from 10,476 m, all are from the North Pacific ocean. The deep-sea extends from 1100 m to depths greater than 7000 m. It is a region of relatively uniform conditions. The temperature ranges from 5 to -1"0C. There is no solar light in the deep-sea. Deep-sea ...

1986-06-08

473

Luminescent properties of Eu3+-activated Sr3B2SiO8: A red-emitting phosphor for white light-emitting diodes  

International Nuclear Information System (INIS)

Single-phased Sr3B2SiO8:Eu3+ phosphor was prepared by a solid-state method at 1020 oC. The luminescence spectra showed that Sr3B2SiO8:Eu3+ phosphor can be effectively excited by near ultraviolet light (393 nm) and blue light (464 nm). When excited at 393 or 464 nm Sr3B2SiO8:Eu3+ exhibited the main emission peaks at 611 and 620 nm, which resulted from the supersensitive 5D0#->#7F2 transition of Eu3+. The luminescence intensity of Sr3B2SiO8:Eu3+ at 611 and 620 nm reached the maximum when the doping content of Eu3+ was 4.5 mol%. Its chromaticity coordinates (0.646, 0.354) were very close to the NTSC standard values (0.67, 0.33). Thus, Sr3B2SiO8:Eu3+ is considered to be an efficient red-emitting phosphor for long-UV InGaN-based light-emitting diodes. - Highlights: ? Sr3B2SiO8:Eu3+ was synthesized using solid-state reaction method for the first time. ? The phosphor can be efficiently excited by the near-UV chips and gives ...

2011-07-01

474

AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION  

Energy Technology Data Exchange (ETDEWEB)

Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. This second six-month technical report summarizes the progress made towards defining, designing, and developing the hardware and software segments of the airborne, optical remote methane and ethane sensor. The most challenging task to date has been to identify a vendor capable of designing and developing a light source with the appropriate output wavelength and power. This report will document the work that has been done to identify design requirements, and potential vendors for the light source. Significant progress has also been made in characterizing the amount of light return available from a remote target at various distances from ...

2003-11-12

475

A wirelessly powered and controlled device for optical neural control of freely-behaving animals.  

Science.gov (United States)

Optogenetics, the ability to use light to activate and silence specific neuron types within neural networks in vivo and in vitro, is revolutionizing neuroscientists' capacity to understand how defined neural circuit elements contribute to normal and pathological brain functions. Typically, awake behaving experiments are conducted by inserting an optical fiber into the brain, tethered to a remote laser, or by utilizing an implanted light-emitting diode (LED), tethered to a remote power source. A fully wireless system would enable chronic or longitudinal experiments where long duration tethering is impractical, and would also support high-throughput experimentation. However, the high power requirements of light sources (LEDs, lasers), especially in the context of the extended illumination periods often desired in experiments, precludes battery-powered approaches from being widely applicable. We have developed a headborne ...

2011-06-23

476

Transplacental movement of inorganic lead in early and late gestation in the mouse  

Energy Technology Data Exchange (ETDEWEB)

/sup 203/Pb(NO/sub 3/)/sub 2/ was administered i.v. to pregnant C57BL mice at different stages, from day 8 to day 18 of gestation. The whole animals or excised uteri were subjected to autoradiography or were autopsied for scintillation counting of excised organs. Lead appeared in embryonic and fetal tissues at all stages of gestation. Early (approx. day 8-11) lead was restricted mainly to the embryonic blood, suggesting that free lead was essentially not transferred to the embryo but may have been incorporated in the embryonic hemoglobin when the erythrocytes were formed in the yolk sac placenta (an extraembryonic membrane). From day 12 and later, an uptake was seen in the liver and the cartilaginous skeleton, and from day 14, a strong accumulation was found in calcified bone. This means that the overall fetal concentration increases successively with gestational age of the conceptus. The uptake in fetal liver may be related to the erythropoiesis taking place in ...

1983-10-01

477

Transplacental movement of inorganic lead in early and late gestation in the mouse  

International Nuclear Information System (INIS)

"2"0"3Pb(NO_3)_2 was administered i.v. to pregnant C57BL mice at different stages, from day 8 to day 18 of gestation. The whole animals or excised uteri were subjected to autoradiography or were autopsied for scintillation counting of excised organs. Lead appeared in embryonic and fetal tissues at all stages of gestation. Early (approx. day 8-11) lead was restricted mainly to the embryonic blood, suggesting that free lead was essentially not transferred to the embryo but may have been incorporated in the embryonic hemoglobin when the erythrocytes were formed in the yolk sac placenta (an extraembryonic membrane). From day 12 and later, an uptake was seen in the liver and the cartilaginous skeleton, and from day 14, a strong accumulation was found in calcified bone. This means that the overall fetal concentration increases successively with gestational age of the conceptus. The uptake in fetal liver may be related to the erythropoiesis taking place in the liver in ...

478

The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers  

International Nuclear Information System (INIS)

There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z cargoes much more readily than the delayed neutrons. Coupled with their higher ...

2004-01-28

479

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

480

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements were performed at ...

2006-07-01

481

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...

1982-06-25

482

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size (MMAD 0.25 ..mu..m +- 0.1) by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of 12 2-in. scintillation detectors and two 2-in. leg counters, all coupled to single channel analyzers. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 h. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes ...

1980-04-01

483

Prompt fission neutron energy spectra induced by fast neutrons  

International Nuclear Information System (INIS)

Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight techniques with pulse-shape ...

484

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal magnetohydrodynamic growth time ...

2007-04-07

485

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the experimental value of dose sensitivity reaches ...

1993-10-13

486

HALO - the helium and lead observatory for supernova neutrinos  

Energy Technology Data Exchange (ETDEWEB)

The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron excess of a heavy nucleus like Pb acts to Pauli-block p)n ...

2008-11-01

487

Experimental investigation and modelling of tritium washout by precipitation in the area of the nuclear power plant of Paks, Hungary  

International Nuclear Information System (INIS)

Tritium occurs in nature in trace amounts, but its concentration is changing due to natural and artificial sources. Studies focusing on natural tritium have to take into account the effect of artificial sources. Also, the impact of tritium is an important issue in environmental protection, e.g. in connection with the emissions from nuclear power plants. The present work focuses on the rain washout of tritium emitted from the Paks nuclear power plant in Hungary. Rainwater collectors were placed around the plant and after a period of precipitation, rainwater was collected and analysed for tritium content. Samples were analysed using low-level liquid scintillation counting, with some also subject to the more accurate "3He ingrowth method. The results clearly show the trace of the tritium plume emitted from the plant; however, values are only about one order of magnitude higher than environmental background levels. A washout model was devised to estimate the ...

2011-01-01

488

Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry  

Energy Technology Data Exchange (ETDEWEB)

In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...

1981-02-01

489

Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry  

International Nuclear Information System (INIS)

In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...

490

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the travel time for the ...

2006-11-13

491

Effect of transforming growth factor beta on synthesis of glycosaminoglycans by human lung fibroblasts  

Energy Technology Data Exchange (ETDEWEB)

The processes of lung growth, injury, and repair are characterized by alterations in fibroblast synthesis and interstitial distribution of extracellular matrix components. Transforming growth factor beta (TGF-beta), which is postulated to play a role in modulating lung repair, alters the distribution of several matrix components such as collagen and fibronectin. We studied the effect of TGF-beta on the synthesis and distribution of the various glycosaminoglycans (GAGs) and whether these effects may explain its role in lung repair. Human diploid lung fibroblasts (IMR-90) were exposed to various concentrations of TGF-beta (0-5 nM) for variable periods of time (0-18 h). Newly synthesized GAGs were labeled with either (3H)glucosamine or (35S)sulfate. Individual GAGs were separated by size exclusion chromatography after serial enzymatic and chemical digestions and quantitated using scintillation counting. There was a dose-dependent increase in total GAG synthesis with ...

1990-09-01

492

Development of low-level liquid-waste treatment systems: April-September 1982  

Energy Technology Data Exchange (ETDEWEB)

A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show that cesium removal is affected by (K/sup ...

1982-12-22

493

Development of low-level liquid-waste treatment systems: April-September 1982  

International Nuclear Information System (INIS)

A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show that cesium removal is affected by [K"+] ...

494

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was ...

2007-09-21

495

Calibration of cylindrical detectors using a simplified theoretical approach  

Energy Technology Data Exchange (ETDEWEB)

The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical approach based on the Direct ...

2006-09-15

496

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass ...

2010-09-07

497

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes very long resulting ...

2005-11-23

498

Activation analysis of trace elements in titanium-molybdate target used for pre-formed TiMo gel based "9"9"mTc generator production and radionuclidic impurity of "9"9"mTc pertechnetate eluate  

International Nuclear Information System (INIS)

A gel-type "9"9Mo-"9"9"mTc generator using Titanium-Molybdate target (TiMo-target) as column packing was developed in Radioisotope Department, the Dalat Nuclear Research Institute [1]. The concentration of trace elements in TiMo-target and radionuclidic purity in "9"9"mTc solution eluted from this type of generator were studied for quality control purpose. The monostandard method in neutron activation analysis has been applied to determine the concentration of trace impurities in titanium-molybdate target. For neutron activation analysis, TiMo samples were irradiated in the different channels of nuclear reactor IVV-9 at a neutron flux of maximum 2.1 x 10"1"3 n.cm"-"2s"-"1. The following chemical element impurities were determined: Na, W, Co, Fe, Zn, Ag, Sb and Cr. The gamma ray emitted nuclides found in "9"9"mTc solution eluted from our "9"9"mTc generator were the following: "6"5Zn, "6"0Co, "1"1"0"mAg, "5"9Fe, "5"1Cr, "2"4Na, "8"2Br and "9"9Mo. "9"9Mo was found less than 2.10"-"6mCi ...

2004-06-01

499

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into new tracer compounds, and reducing the cost ...

2009-03-07

500

/sup 242/Am/sup m/ fission cross section  

Energy Technology Data Exchange (ETDEWEB)

The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy region, and a systematic uncertainty of ...

1984-06-01