WorldWideScience
 
 
1

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

2

Synthesis of iodine-125 labelled aryl and vinyl iodides  

Energy Technology Data Exchange (ETDEWEB)

Iodine-125 labelled vinyl and aryl iodides are formed via the reaction of sodium iodide-125 with vinyl- and arylboronic acids. Good yields of isomerically pure products are obtained.

1982-06-01

3

Synthesis and properties of N,N-dialkyl-P-phenylphosphonamidous iodides  

Energy Technology Data Exchange (ETDEWEB)

N,N-Dialkyl-P-phenylphosphonamidous iodides are formed in the reactions of phenylphosphonus diiodide with silylated secondary amines. N,N-Dialkyl-P-phenylphosphonamidous iodides react with electrophilic reagents (methyl iodide, benzenesulfonyl azide, and phenyl azide) by the usual schemes with the formation of alkylation and oxidative-imination products. Iodine catalyzes the disproportionation of morpholinophenylphosphinous iodide into dimorphomorpholinophenylphosphinous iodide with iodine are iododimorpholinophenylphosphonium triiodide and phenylphosphonous diiodide.

1987-01-20

4

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

5

Pure Scandium Production  

International Science & Technology Center (ISTC)

Development of the Technology to Obtain Pure Metal Scandium by Thermal Decomposition of Scandium Iodide

6

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

7

Gas diffusion electrodes for the oxidation of sulfur dioxide in the presence of potassium iodide. [In hydrogen production by electrolysis of sulfuric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

The oxidation of sulfur dioxide in gas diffusion electrodes (GDE) in the presence of a homogeneous catalyst, potassium iodide, is investigated. The influence of this catalyst on the voltage-current (V-I) characteristics of the electrodes and the utilization of sulfur dioxide is determined. It is shown that when using the homogeneous catalyst potassium iodide, the utilization can reach 95-100%.

1986-01-01

8

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

9

Inhibitors of steel corrosion in hydrochloric acid at high temperature  

Science.gov (United States)

A proposed inhibitor for steel corrosion in hydrochloric acid consists essentially of 0.5% of an inhibitor called BA-6, 0.25-0.5% of 1-hexynol-3, and about 0.02% of potassium iodide (calculated on the amount of acid). The inhibitor DA-6 is produced by condensing benzylamine with utrotropine. 1-Hexynol-3, secondary alcohol, is obtained from butyraldehyde and acetylene in the presence of caustic potash. The increase of potassium iodide concentration from 0.02-0.1% increases the protective action of the inhibitor. Hexynol, dipropargyl ester, and potassium iodide must be introduced in HC1 before injection of the latter into the well.

1965-01-07

10

Luminescence properties of thallium crystal phosphors and their use in determining microgram quantities of thallium  

Energy Technology Data Exchange (ETDEWEB)

The preparation and luminescence properties of crystal phosphors based on alkali metal iodide and calcium oxide substrates were studied. The highest luminescence intensities were achieved with iodide substrates at 200/sup 0/ and with the calcium oxide substrate at 800/sup 0/. The calibration graphs were linear in the thallium concentration ranges 0.03-5.0 and 0.1-2.0 mu g using sodium and potassium oxides, respectively, and in the range 0.05-5 mu g using cesium iodide and calcium oxide. A method is proposed for the determination of down to 3 x 10/sup -4/% thallium in rocks, using a crystal phosphor with sodium iodide substrate.

1986-02-01

11

7257 - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Molar extinction coefficients of hydrogen iodide in the Schumann region. Author: De More, W. B.; Raper, O. F.. Abstract: Molar extinction ...

12

Anodic behavior of titanium in sodium iodide solutions. Anionic anodic activation  

Energy Technology Data Exchange (ETDEWEB)

Results are reported which were obtained when investigating the anodic behavior of titanium in sodium iodide solutions. It was concluded that in order to explain the special features in the anodic behavior and anionic anodic activity of titanium one must take into account, both a redistribution of the potential drop between the oxide and the Helmholtz layer and a potential-dependent variation of the catalytic and adsorption properties of the oxidized titanium anode.

1987-02-01

13

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

14

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

15

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

16

Kinetic aspects of the photolysis of in-station airborne methyl iodide  

International Nuclear Information System (INIS)

A method for converting organic iodides to elemental iodine would be advantageous in improving the performance of charcoal filters for the removal of radio iodines from reactor off gases. A photochemical method has been developed. The HAVCHM code was used to establish the relevant process time scales on a complete set of rate equations describing the primary and secondary reactions occurring in a plug-flow reactor containing low levels of elemental iodine and methyl iodide in air, which is irradiated by intense u.v. light. These simulations were used to justify the contraction of the complete set of reactions to the most significant elementary processes. The contracted set of rate equations are then solved analytically to render the concentration-time profiles of methyl iodide, total inorganic iodine and total oxidized organics, consistent with the achievement of a desirable radioiodine decontamination factor. For the short ...

17

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...

1996-12-31

18

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

19

Synergistic effect of iodide ion and polyacrylic acid on corrosion inhibition of iron in H2SO4 investigated by electrochemical techniques  

British Library Electronic Table of Contents (United Kingdom)

Corrosion inhibition of iron in H2SO4 by polyacrylic acid (PAA) was investigated using electrochemical techniques at 30degreeC. Results obtained indicate that PAA inhibited the corrosion of iron in the acid medium. Inhibition efficiency increases with increase in PAA concentration and synergistically enhanced on addition of iodide ions. Potentiodynamic polarization results suggest that PAA functions as a modest cathodic inhibitor. The adsorption of PAA onto the iron surface followed Temkin adsorption isotherm. FTIR analysis revealed that the synergistic effect due to co-adsorption of iodide ions and PAA is co-operative in nature.

2010-01-01

20

Removal of iodine species by concentrated nitric acid, (2)  

International Nuclear Information System (INIS)

One of the most effective removing processes of iodine species is what is called ''Iodox Process'', which contains oxidation and absorption of iodine species by highly concentrated nitric acid. The result of fundamental test with bubble column in this process had been reported. Present paper describes the fundamental experiment by the use of packed column. This experiment has been carried out to clear the effect of feed gas flow rate, nitric acid flow rate, nitric acid concentration, and methyl iodide concentration on removal efficiency of methyl iodide. The following results were obtained. The decontamination factor of methyl iodide (DF) increases exponentially with nitric acid concentration, which agrees with the result obtained by using the bubble column. The factor is in inverse proportion to feed gas flow rate, and is also almost independent of nitric acid flow rate and methyl iodide concentration. ...

1978-07-01

 
 
 
 
21

Palladium-catalyzed Heck-type reaction of oxime ether bearing a pendant vinyl iodide moiety.  

Science.gov (United States)

A Pd(0)-catalyzed intramolecular Heck-type reaction of oxime ether has been developed, providing convenient access to heterocyclic oximes. PMID:21964259

2011-10-01

22

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

23

Studies on technology improvement in the production of iodine and bromine  

International Nuclear Information System (INIS)

Results of studies dealing with improvement of the currently employed technology of iodine and bromine production by processing iodine- and bromine-containing borehole effluent water were considered. Potentiality of selective oxidation of iodide-ions in the presence of bromide-ions in acidified borehole effluent water with addition of ozone for initiating oxidation of iodide-ions and iron(2) salt to prevent bromine evolution was confirmed experimentally. Conditions were determined that rule out bromine formation in the solution, but simultaneously permit varying the yield of iodine within 70-100%

2001-07-01

24

Stability constants of At(I)-complexes with thiourea, iodide and mixed ligands in ethanol and water  

International Nuclear Information System (INIS)

The ion mobilities of |"2"1"1At|At(I) in dependence on thiourea (tu) concentration, iodide concentration and a mixture of both ligands were measured by the electromigration method in free electrolytes. An equilibrium model was developed for the characterization of electromigration curves which permitted the calculation of stability constants and ion mobilities of the complexes |AtI|, |AtI_2|"-, |Attu|"+, |Attu_2|"+ and |AtItu| existing in these solutions. Ethanol and water served as solvents. The temperature was 298 K and the ionic strength was about 0.05 mol/dm"3. (author) 16 refs.; 2 figs.

25

Radioiodide uptake in brain, CSF, thyroid, and salivary glands of audiogenic seizure mice  

Energy Technology Data Exchange (ETDEWEB)

DBA/2J (DBA) mice are susceptible to audiogenic seizures (ASs) in an age-dependent manner. Anion transport as measured by radioiodide uptake was determined in thyroid gland, salivary gland, skeletal muscle, cerebral cortex, cerebellum, brainstem, and CSF from these mice at various ages. Anion transport was also determined in C57BL/6J(C57) mice, an AS-resistant strain. In thyroid, DBA mice had an enhanced ability to concentrate iodide at 21 days of age when they have maximal AS susceptibility, as compared with the same-aged C57 mice. This difference in thyroid function was less marked at 40 days of age, when DBA mice are less AS susceptible, and was absent at 110 days of age, when DBA mice are AS resistant. In brain, differences in iodide uptake were also noted between these two strains of mice at 21 days of age. DBA mice had an increased concentration of iodide in CSF, an indication that they have a defect in the transport ...

1984-08-01

26

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

27

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

28

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

29

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

30

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

31

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

32

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

33

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

34

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

35

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

36

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

37

Oxidation of trivalent arsenic to pentavalent arsenic with oxygen in the presence of nitrite and iodide ions  

Science.gov (United States)

In view of the effect of the acidity on the oxidation potentials of nitrous, arsenous, and arsenic acids, one should expect a complex relationship between the rate of arsenic (III) to arsenic (V) and the pH of the solution. They studied the kinetics of the reaction 2AsO/sub 2//sup -/ + O/sub 2/ ..-->.. 2AsO/sub 3//sup -/ as functions of concentrations (partial pressure) of all the components of the system NaAsO/sub 2/-HCl(HClO/sub 4/)-NaNO/sub 2/-KI-H/sub 2/O-O/sub 2/ and temperature. The study of the kinetics of arsenic(III) oxidation to arsenic(V) with oxygen in the presence of sodium nitrite and iodide ions showed that the reaction rate passes through a maximum at an acid content of 1.2-2.5 M and rises in proportion to the second exponent of the sodium nitrite concentration and to the first exponent of the iodide ion concentrations and partial oxygen pressure. A fall in the temperature facilitates intensification of the process and ...

1986-10-20

38

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...

39

pH and iodide ion effect on corrosion inhibition of histidine self-assembled monolayer on copper  

International Nuclear Information System (INIS)

Self-assembled monolayer (SAM) of histidine (His) was prepared on copper surface at various pH values. The effect of KI additives on corrosion protection efficiency of His SAM was also studied. The protection abilities of these films against copper corrosion in 0.5 M HCl aqueous solution were investigated using electrochemical impedance spectroscopy and polarization techniques. The results show that the film formed on the electrode is more stable at pH = 10 than that at other pH values. When the iodide ions were added into the His self-assembly solution (pH = 10), protection efficiency was further improved. The inhibition mechanism has been discussed by quantum chemical calculations.

2010-03-01

40

Semiconductor photophysics. 5. Charge carrier trapping in ultrasmall silver iodide particles and kinetics of formation of silver atom clusters  

International Nuclear Information System (INIS)

Reactions of reducing species from acetonitrile media with silver iodide particles (#approx#25-angstrom diameter) have been investigated by pulse radiolysis techniques. Injection of electrons into these ultrasmall particles leads to transient bleaching of the adsorption of AgI at wavelengths close to the onset of absorption (#approx#400 nm) with the concomitant reduction of AgI to metallic silver. The reduction of Ag"+ ions and formation of silver atoms and/or dimeric Ag_2 molecules on three different size AgI particles (#approx#100, 35, and #approx#25 angstrom) have also been examined by picosecond laser spectroscopy.

 
 
 
 
41

Polymer-metal complex as gel electrolyte for quasi-solid-state dye-sensitized solar cells  

International Nuclear Information System (INIS)

A kind of polymer-metal complex gel electrolyte is successfully prepared and is used in dye-sensitized solar cells. Raman and X-ray photoelectron spectroscopy confirm the structure of this complex and is found that the metal ion reacts with nitrogen in the polymer. This novel electrolyte shows apparent diffusion coefficient of iodide of 8.37 x 10-7 cm2 s-1 and the energy conversion efficiency of 6.10% when the amount of ZnI2 is 0.04 M. By studying the dissociation active energy of the inorganic salt in electrolytes, we find that the metal salts can dissociate more easily after reacting with polymer and as a result can provide extra free iodide ion. The cell maintains ca. 93% of its initial efficiency after 20 d without further sealing, which shows good long-time stability.

2011-01-01

42

Stabilization of measuring channel of reflective gamma thickness gage by light pulses from additional scintillator  

International Nuclear Information System (INIS)

Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.

43

Formation and stability of astatide-mercury complexes  

International Nuclear Information System (INIS)

The formation of astatide-mercury complexes was investigated in aqueous solutions.The obtained complexes were examined by paper electrophoresis. It was found that Hg(OH)At and Hg(OH)I complexes were formed in neutral solution. The stability constants of the obtained complexes were determined by ion-exchange. The preliminary results indicate that the complex of mercury with astatide is much more stable than similar complexes with iodide. (author)

2006-04-01

44

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

45

Enhanced anti-tumor effects of combined MDR1 RNA interference and human sodium/iodide symporter (NIS) radioiodine gene therapy using an adenoviral system in a colon cancer model  

UK PubMed Central (United Kingdom)

Using an adenoviral system as a delivery mediator of therapeutic gene, we investigated the therapeutic effects of the use of combined MDR1 shRNA and human NIS (hNIS)...Full Text Available

2010-07-01

46

Effect of KI on improving copper corrosion inhibition efficiency of benzotriazole in sulfuric acid electrolytes  

Energy Technology Data Exchange (ETDEWEB)

A synergistic effect exists when benzotriazole (BTAH) and iodide ions are used together to prevent the corrosion of copper in sulfuric acid. The nature of this effect has been studied systematically by using electrochemical techniques and X-ray photoelectron spectroscopy. The synergistic effect is due largely to the formation of a film of Cu(IBTA) complex and is probably polymeric in nature. This new complex film greatly depresses copper dissolution.

1993-10-01

47

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

48

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

49

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

50

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

51

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

52

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

53

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

54

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

55

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

56

Inhibition of corrosion resistant alloys in hot hydrochloric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Weight loss measurements were performed in 20% and 28% hydrochloric acid at 90/sup 0/C on carbon steel, 22Cr5Ni duplex stainless steel, and two superaustenitic steels - 27Cr31Ni3Mo and 19Cr25Ni4Mo -, in presence of organic substances used singly or mixed. The organic substances examined were quaternary ammonium salts (1-4-pyridyl)-pyridinium chloride hydrochloride, dodecylpyridiniumchloride, benzyldimethylstearylammonium chloride, and dodecyltrimethylammonium bromide), alkynols (1-octyn-3-ol, propargyl alcohol) and trans-cinnamaldehyde. The synergistic effect of potassium iodide on the inhibitive efficiency of the organic substances was studied. The variations of corrosion rate during the test time (normally six hours) were recorded by means of polarization resistance measurements. Polarization curves were also recorded. The results showed that the corrosion rates of the four steels examined can be reduced to less than 1 mg/cm/sup -2/ . h/sup -1/ using ternary ...

1988-12-01

57

Design, synthesis and evaluation of redox radiopharmaceuticals: a potential new approach for the development of brain imaging agents  

International Nuclear Information System (INIS)

The fabrication and complete evaluation are described of a dihydropyridine in equilibrium pyridinium salt type redox system for the delivery of radioiodinated agents to the brain. The pivotal intermediate, N-succinimidyl (1-methylpyridinium iodide)-3-carboxylate was prepared by condensation of nicotinic acid and N-hydroxysuccinimide in the presence of dicyclohexylcarbodimide, followed by quaternization of III with methyl iodide. Tissue distribution studies of "1"2"5I-labeled 4-iodoaniline and the redox agents were performed in rats. ["1"2"5I]Iodoaniline initially showed moderate (0.58% dose/gm) brain uptake with subsequent release of the radioactivity from the brain. ["1"2"5I]Iodoaniline, when coupled to a dihydropyridine carrier showed higher uptake and retention in the brain. The ["1"2"5I]iodophenylethyl analogue showed uptake and retention in the brain to be very similar. Apparently the lipophilic agents cross the blood-brain barrier and are ...

58

Cluster-assisted multiple ionization of methyl iodide by a nanosecond laser: Influence of laser intensity on the kinetic energy and peak profile of multicharged ions  

International Nuclear Information System (INIS)

The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus point. The linear dependence of kinetic energy of multicharged ions on laser intensity is interpreted by the ionization mechanism, in which the laser induced inverse bremsstrahlung heating ...

2006-03-20

59

Solid state alkali metal-halogen cell  

Energy Technology Data Exchange (ETDEWEB)

A solid electrolyte cell comprises an alkali metal anode, e.g. lithium, a halogen-containing organic polymer cathode and a solid elecrolyte between the anode and the cathode. The cathode comprises iodine-containing vacuum-cyclised polyacrylonitrile, and the solid electrolyte is preferably lithium iodide and halogen-free vacuum-cyclised polyacrylonitrile. This patent also discloses the use of isotactic polyacrylonitrile, a method of making a cathode comprising iodine-containing vacuum-cyclised polyacrylonitrile, and novel methods of making the solid elecrolyte cells described.

1988-04-26

60

Quantitative analysis of iodine in thyroidin. II. Method of combustion in flask with oxygen  

Energy Technology Data Exchange (ETDEWEB)

The authors experimentally study the separate stages of the determination of iodine in thyroidin by the combustion method in a flask with oxygen. The monotypic, conventional procedures and the procedure of Kolii and Pakhomov were studied. With addition of potassium iodide, a sixfold amount (compared with the initial) of iodine is liberated. Further, the liberated iodine is titrated by sodium thiosulfate. The authors find the degree of influence of a high nitrogen content on the determination of iodine in organic compounds. The procedure developed for the quantitative determination of the iodine in thyroidin by the combustion method is simple, fairly rapid, and can be used for the reliable control of the quality of thyroidin preparations and its starting raw material.

1986-11-01

 
 
 
 
61

Preparation of poly (aryl ether ketones) in the presence of an alkali, alkaline earth of lanthanide metal salt  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a process for preparing poly(aryl ether ketones) by nucleophilic displacement polymerization in the presence of at least one alkali metal base selected from potassium, rubidium or cesium, and fluoride ions, which comprises adding to the polymerization: (a) an effective amount of at least one metal salt selected from lithium, sodium, alkaline earth or lanthanide chloride, bromide, iodide, sulfate, alkyl or aryl carboxylate, cyanide, borate or phosphate to slow or stop advancement of molecular weight and (b) an end-capping agent.

1988-09-27

62

Heterogeneity effects in adsorption kinetics of gas mixtures. [C/sub 1/-C/sub 4/ hydrocarbons  

Energy Technology Data Exchange (ETDEWEB)

An analysis based on Jaroniec's theory of mixed gas adsorption showed that for two arbitrary adsorbing gas components the ratio of their surface coverages is a simple power function of the ratio of their partial pressures. This result was verified with available experimental data on the adsorption of C/sub 1/-C/sub 4/ hydrocarbon binary mixtures, CO/sub 2//C/sub 2/H/sub 4/, and N/sub 2//CO on various carbons, silica gel, and cesium iodide.

1980-01-01

63

Extraction of magnesium as the iodide by tributyl phosphate  

Science.gov (United States)

The extraction of magnesium by tributyl phosphate from KI solutions was investigated. With increasing KI and TBP concentrations, the extraction increased. The maximum extraction (82%) was attained at pH 4, and it did not decrease with a further pH increase. With decreasing pH, the extraction decreased because of HI extraction. The magnesium was extracted as the compound MgI/sub 2/ x 4TBP. Complexone III (at pH 3-4) does not affect the extraction of magnesium, which makes it possible to use it to mask other metals.

1987-08-20

64

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

65

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

66

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

67

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

68

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

69

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

70

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

71

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

72

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

73

Fission product speciation in Phebus tests FPT0 and FPT1 and the possible influence of boron  

Energy Technology Data Exchange (ETDEWEB)

The thermochemical calculations performed with a large number of elements to describe the chemical system in a Phebus FP test allow the following conclusions: The metallic absorber materials play a significant role in fission product speciation. At around 1000 C and above, silver iodide is the dominant iodine carrier in a full steam atmosphere in both FPT0 and FPT1. At lower temperatures, cadmium iodide takes over. In a reduced environment, indium iodide becomes important. Caesium iodide does certainly appear; at certain test conditions it becomes the major iodine transporting vehicle. But its role is not greater than that of the other iodides. It has more chances in FPT1 than in FPT0. Chlorine, which was present in FPT0 as a contaminant in relatively large amounts, does not prevent the iodine from forming Csl. Both share the caesium like partners. The evolution of caesium chloride ...

1996-01-01

74

The separation of "2"0"3Pb from a thallium target  

International Nuclear Information System (INIS)

"2"0"3Pb, an ideal radionuclide for toxicological studies, can be artificially produced by bombardment of a thallium target but due to the extreme toxicity of thallium the lead has to be separated completely from the thallium. A single step method is here described consisting of removing the thallium from a dilute acid chloride solution using a continuous ethyl ether extraction. Essentially all of the thallium and almost none of the lead is removed in a 3-hr extraction. Because the ether is recycled, only about 30 ml are needed. If other contaminants are introduced from the bombardment and its subsequent manipulations, an additional step is used in which the lead is extracted from an iodide solution with methyl isopropyl keton. (U.K.).

75

The in vivo measurement of radiocaesium activity in broiler chickens  

Energy Technology Data Exchange (ETDEWEB)

Contamination of certain areas of Europe with radiocaesium from the Chernobyl accident led to a higher {sup 137}Cs accumulation (i.e. 300-600 Bq kg{sup -1}) in grain and to potential post-accident contamination of broiler chickens. In future, such contamination may require a simple determination of the {sup 137}Cs activity concentration in broiler chicken meat which would lead to measures for preventing the recommended limits of radionuclide contamination of the meat for human consumption from being exceeded. This paper describes the development of a rapid method for the in vivo monitoring of the broiler chicken using a lead-shielded sodium iodide detector. The method enables simply fixed live chicken to be monitored, the results showing a good correlation (R{sup 2}=0.98) with measurements of meat from chicken previously monitored in vivo prior to slaughter.

2000-05-01

76

Synthesis of C-11 iodoantipyrine for positron emission tomography  

Energy Technology Data Exchange (ETDEWEB)

We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.

1981-06-01

77

Structure and antimicrobial activity relationship of quaternary N-alkyl chitosan derivatives against some plant pathogens  

British Library Electronic Table of Contents (United Kingdom)

In the present work, quaternary chitosans as water-soluble compounds were prepared based on three-step process. Schiff bases were firstly synthesized by the reaction between the amino groups of chitosan with aliphatic aldehydes followed by a reduction with sodium borohydride (NaBH4) to form N-(alkyl) chitosans. N,N,N-(dimethyl alkyl) chitosans were then obtained by a reaction of chitosan containing N-butyl, N-pentyl, N-hexyl, N-heptyl, and N-octyl substituents with methyl iodide. The compounds were characterized using IR and NMR spectroscopy. Subsequent experiments were conducted to test their antimicrobial activities against the most economic plant pathogenic bacteria of crown gall disease Agrobacterium tumefaciens, soft mold disease Erwinia carotovora, fungi of grey mold Botrytis cinerea...

2010-01-01

78

SZ-685C, a marine anthraquinone, is a potent inducer of apoptosis with anticancer activity by suppression of the Akt/FOXO pathway  

British Library Electronic Table of Contents (United Kingdom)

Background and purpose: The aims of this study were to investigate the anti-cancer activity of SZ-685C, an anthracycline analogue isolated from marine-derived mangrove endophytic fungi, and to explore the molecular mechanisms underlying such activity. Experimental approach: The effect of SZ-685C on the viability of cancer cell lines was investigated using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. SZ-685C-induced apoptosis was assessed by Annexin V-fluorescein isothiocyanate/propidium iodide staining, terminal deoxynucleotidyl transferase-mediated dUTP nick end labelling assay and analysis of caspase activation. The effect of SZ-685C on the Akt/FOXO pathway was studied using Western blotting analysis, and the in vivo anti-tumour efficacy was examined in ...

2010-01-01

79

Radioiodinated 1-substituted-4-phenylpiperazines as potential brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.

1985-01-01

80

Production of tetrazolium salts under conditions of phase-transfer catalysis  

Energy Technology Data Exchange (ETDEWEB)

Recently the authors showed that tetrazolium salts can be obtained during the oxidation of substituted 1,3,5-triarylformazans with potassium permanganate in a two-phase organic solvent-water system. The role of phase-transfer catalyst in this reaction is played by the tetrazolium salt, which is formed in a small amount as the result of oxidation of the formazan at the phase boundary. The method is distinguished by its extreme simplicity. However, the yield of the tetrazolium salts fluctuates within wide limits and does not exceed 62%. This is due to the fact that as the reaction proceeds the pH of the aqueous phase increases from 6 to 12. At the same time it is known that tetrazolium salts are unstable in aqueous alkaline solutions. They found that if the aqueous phase is replaced by aqueous hydrochloric acid (5 wt. %) the yields of the tetrazolium salts (Ia-g) are increased to 70-87%. For convenience of isolation the readily water-soluble tetrazolium chlorides were converted into the ...

1988-06-20

 
 
 
 
81

Ionically conductive thin polymer films prepared by plasma polymerization. Pt. 7. Preparation and characterization of solid polymer electrolyte having fixed carboxylic acid groups with single mobile species  

Energy Technology Data Exchange (ETDEWEB)

Ultra-thin, uniform, pinhole-free solid polymer electrolyte films having a fixed carboxylic ester group of approximately 1 {mu}m thickness were prepared by polymerization of methyl acrylate and tris(2-methoxyethoxy)vinylsilane in a glow discharge plasma. The carboxylic ester group of the plasma polymer were transformed to lithium carboxylate groups by treatment with lithium iodide. This process give a single lithium ion conductive film. These solid polymer electrolyte films showed ionic conductivities of the order of 10{sup -8} S cm{sup -1} (10{sup 4} {omega} cm{sup 2} resistance per unit area) at room temperature. (orig.).

1990-08-01

82

Ionically conductive thin polymer films prepared by plasma polymerization  

International Nuclear Information System (INIS)

Ultrathin solid polymer electrolyte membranes containing sulfonic ester groups were prepared by polymerization of methyl benzenesulfonate and octamethylcyclotetrasiloxane in a glow discharge plasma. The sulfonic ester groups of the plasma polymer were transformed to lithium sulfonate groups by treatment with lithium iodide. Hybridization of this plasma polymer containing the lithium sulfonate groups with poly(ethylene oxide) (average Mw 300) resulted in the formation of a single lithium ion conductive film. The hybrid polymer electrolyte films were about 1 #mu#m thick, pinhole-free, adherent to various substrates, and showed ionic conductivities at 60 degrees C of the order of 10"- "6 S cm"- "1 (10"2 #OMEGA# cm"2 resistance per unit area of as-prepared solid polymer electrolyte). This material shows promise for electrochemical applications such as all solid-state lithium batteries, sensors, and electrochemical display devices.

83

Infrared spectroscopy of rovibrational transitions of methyl radicals (CH3, CD3) in solid parahydrogen  

British Library Electronic Table of Contents (United Kingdom)

The n3 and n4 vibrational transitions of CH3 and CD3 isolated in solid parahydrogen were studied by high-resolution infrared spectroscopy. The radicals were produced by in situ UV photolysis of methyl iodides trapped in solid parahydrogen. The observed spectra showed clear rotational fine structures, which were subjected to further splitting due to the electrostatic field of solid parahydrogen. The molecular constants and crystal field parameters of the radicals in solid parahydrogen were determined by analyzing the spectral structures of the n3 and n4 transitions of CD3 by the crystal field theory. The rotational constants of the CD3 radical were found to be only a few percent smaller than those in the gas phase. The determined crystal field parameters indicated significant quantum effect...

2011-01-01

84

Gas chromatographic, quentum-chemical, and molecular statistical studies of cluster adsorption of water and methanol molecules on hydrophilic surface sites of hydrophobic adsorbents  

British Library Electronic Table of Contents (United Kingdom)

The comprehensive theoretical and experimental study of the adsorption of water and methanol molecules on active sites (carboxyl and phenol hydroxyl groups) on the graphitized thermal carbon black is performed. It is shown that microclusters formed upon the adsorption of these molecules on such sites are characterized by the cyclic structure comprising 4?5 molecules similar to that whose existence was revealed previously in liquid water and on the surface of silver iodide. The analysis of the studied adsorption clusters demonstrated that the formation of such cycles is governed primarily by the hydrogen bonding; however, a definite role is played also by energy effects associated with the changes in the state of molecular motion during adsorption. It is shown that the generalized Langmuir ...

2008-01-01

85

Covalent modification of fused silica capillaries with quaternized polyamines to achieve robust and stable anodic electroosmotic flow  

British Library Electronic Table of Contents (United Kingdom)

Synthetic chemistry originally developed for the manufacture of chemically stable silica polyamine composites was adapted for the modification of fused silica capillaries for application in CE. Polyethyleneimine (PEI) and polyallylamine (PAA) were covalently bonded to the interior surface of fused silica capillaries utilizing 3-chloropropyltrichlorosilane (CPTCS) or 3-glycidoxypropyl-trimethoxysilane (GPTMS) to anchor the polymers to the surface. The surface-bound polymers were subsequently quaternized using methyl iodide (MeI). The resulting modified capillaries were studied using CE, and were shown to provide reproducible, stable, and robust anodic EOF throughout the pH range of 2-10. Surface modifications utilizing CPTCS could be rinsed with up to 6 M HCL or 1 M NaOH without significant...

2009-01-01

86

Beverage iodine levels in Germany  

British Library Electronic Table of Contents (United Kingdom)

Sales of iodized table salt (household use, bulk containers) have been flat in Germany since 1996/1997. Nevertheless, the amount of iodide excreted with the urine has been steadily increasing in the German population since 1993. We investigated the beverage iodine levels as possible source of the increased input of iodine into the food chain. No systematic studies on this topic have yet been carried out in Germany. A total of 510 samples were drawn from large grocery discounters who supply all German states with their products (35% fruit and vegetable juices, 35% beers, 10% pooled milk and yoghurt drinks, 10% mineral water, 10% soda). (1) Water-based beverage samples are prepared by solid-phase extraction and iodine concentration is determined by HPLC and electrochemical detection, (2) the...

2009-01-01

87

Adsorption of iodine ions in modified activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Shaped activated charcoal is modified by 02 and N2 processing for producing coal compounds with higher acidic or basic properties. Nitrated activated charcoal has properties of a weak anionite with a substantially increased ion exchange capacity with an increase in the concentration of the hydrogen ions in the electrolyte and adsorbs iodine ions well from aqueous solutions at a pH of less than 5. A layer of nitrated charcoal is a very effective sorbent in the process of dynamic sorption of iodine anions from acetic solutions of KI. It is also established that the sorption of iodine ions in the activated charcoal modified by 02 occurs in accordance with an ion exchange mechanism (and possibly, selective sorption). This refutes literature data which ascribe the determining participation in the process to the reaction of oxidation of iodides on the surface (Pv) of the coal into free I2.

1983-01-01

88

Technology of iodine-131 production and its application  

International Nuclear Information System (INIS)

Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to ...

89

Small-molecule screen identifies inhibitors of a human intestinal calcium-activated chloride channel.  

Science.gov (United States)

Calcium-activated chloride channels (CaCCs) are widely expressed in mammalian tissues, including intestinal epithelia, where they facilitate fluid secretion. Potent, selective CaCC inhibitors have not been available. We established a high-throughput screen for identification of inhibitors of a human intestinal CaCC based on inhibition of ATP/carbachol-stimulated iodide influx in HT-29 cells after lentiviral infection with the yellow fluorescent halide-sensing protein YFP-H148Q/I152L. Screening of 50,000 diverse, drug-like compounds yielded six classes of putative CaCC inhibitors, two of which, 3-acyl-2-aminothiophenes and 5-aryl-2-aminothiazoles, inhibited by >95% iodide influx in HT-29 cells in response to multiple calcium-elevating agonists, including thapsigargin, without inhibition of calcium elevation, calcium-calmodulin kinase II activation, or cystic fibrosis transmembrane conductance regulator chloride channels. These compounds also ...

2007-12-14

90

Fluoride complexes of Pt(II) as nucleophiles: activity of PtCl/sub 4//sup 2 -/, PtCl/sub 3/(H/sub 2/O)/sup -/, and PtCl/sub 3/(C/sub 2/H/sub 4/)/sup -/ anions in the oxidative addition of methyl iodide  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of the oxidative addition of CH/sub 3/I to platinum(II) complexes in aqueous solutions of K/sub 2/PtCl/sub 4/ and KPtCl/sub 3/(C/sub 2/H/sub 4/) have been studied by PMR and GLC. The second-order rate constants for the PtCl/sub 3/(H/sub 2/O)/sup -/ and PtCl/sub 4//sup 2 -/ particles are equal to 400 exp(-2.7 x 10/sup 3//T) and 3.18 x 10/sup 10/ exp(-9.2 x 10/sup 3//T) mole/sup -1/ x liter x sec/sup -1/, respectively. The introduction of a ..pi..-acceptor ligand, viz. ethylene, into the coordination sphere of platinum(II) results in a sharp drop in the rate, probably due to a decrease in the electron density on the platinum atom. According to the PMR data, the product of the oxidative addition of CH/sub 3/I to Zeise's salt is a methyl complex of platinum(IV), is identical to the complex obtained by reacting methyl iodide with K/sub 2/PtCL/sub 4/, and does not contain an olefin.

1987-05-01

91

Effects of lithium iodide doping on devolatilization characteristics of brown coals; Yoka lithium no tenka ga kattan no kanetsu henka katei ni oyobosu eikyo  

Energy Technology Data Exchange (ETDEWEB)

In order to discuss effects of lithium iodide (LiI) doping on condensation structure of brown coals during heating, spectral changes were measured by using an in-situ FT-IR. It was found that the LiI doping accelerates weight reduction due to heating, and the doping effect is affected by coal structure. Both of Loy Yang (LY) coal and its LiI doped coal (DLY) had absorption intensity of the FT-IR spectra decreased with rising temperature, and the absorption center belonging to an OH group shows different shifts between the LY and DLY coals. This indicates that the LiI doping has affected the change in hydrogen bonding patterns associated with heating. Both of South Banko (SB) and LY coals had the absorption spectral intensity in the OH group decreased as the weight reduction (conversion) rate increased. Reduction in the OH groups associated with heating is caused by volatilization and condensation reaction in light-gravity fraction. However, in the case of equal ...

1996-10-28

92

Effective equivalent dose and radiation risk in radionuclide diagnostics estimated in patients of the Nuclear Medicine Department of the Medical Academy 'Carl Gustav Carus' Dresden  

International Nuclear Information System (INIS)

7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic risk 1.7 x 10"-"5 according to 0.11 malignomas. The average ...

1986-01-01

93

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

94

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

95

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

96

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

97

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

98

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

99

Use of a predictor for total body potassium content: application to nutrition and hypertension  

International Nuclear Information System (INIS)

Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close agreement with a predictor formula, provided higher estimates of lean body mass than did skin fold thickness, and showed no ...

100

The synthesis of 5-[1-"1"1C]ethyl barbiturates from labelled malonic esters  

International Nuclear Information System (INIS)

The synthesis of ["1"1C]phenobarbital, ["1"1C]pentobarbital and["1"1C]amobarbital labelled in the 5-[1-"1"1C]ethyl position is reported. The malonic esters R- CH(CO_2Et)_2 [R phenyl-, 1-methylbutyl-, and 3- methylbutyl- were alkylated with [1-"1"1C]ethyl iodide prepared from ["1"1C]carbon dioxide. Ring closure of the 2-[1-"1"1C]ethyl-labelled malonic esters with urea afforded 5-[1-"1"1C]ethyl-phenobarbital,-phenobarbital, -pentobarbital and -amobarbital synthesis times of 42-47 min, counted from ["1"1C] carbon dioxide. In typical syntheses starting with 3 GBq pentobarbitol and (81 mCi) ["1"1C]carbon dioxide, 150-215 MBq (4-6 mCi) were produced in 25-30% decay corrected -amobarbital radiochemical yields with radiochemical purities greater than 98%. (author).

 
 
 
 
101

Radioiodinated peanut lecitin: A potential radiopharmaceutical for immunodetection of carcinoma expressing the T antigen  

International Nuclear Information System (INIS)

The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to some localisation of free iodide in the ...

1983-01-01

102

Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)  

International Nuclear Information System (INIS)

A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis by basic catalyst, proceeding in the ...

1978-01-01

103

Extraction of molybdenum with a multielement liquid organic extraction system  

Science.gov (United States)

An extraction of molybdenum is described that provides a more predictable separation over a significantly wider acidity range than previously determined. The extraction of Mo appeared to be a function of HCl normality, with virtually complete separation above 3.6 N. A test was conducted to determine if the extraction was a function of just HCl concentration or of overall acidity. When the aqueous phases of the test sequence were all prepared at 1 N H/sub 2/SO/sub 4/ in addition to the HCl in each, the resulting extraction curves were essentially identical. Another test was performed to determine if Mo was being extracted as an iodide complex. Three aqueous solutions, which were 4 N in HCl and 26% (w/v) ascorbic acid, were prepared in culture tubes. When 25 ..mu..g of Mo was extracted from these solutions of 5 mL of organic phase, the KCl gave only a 16% extraction, the KBr gave only a 22% extraction, and the KI provided an essentially total extraction. 4 ...

1985-10-01

104

Effect of halogens and inhibitors on the external stress corrosion cracking of Type 304 austenitic stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The methodology of the drip procedure of the Standard Test Method for Evaluating the Influence of Thermal Insulation on External Stress Corrosion Cracking Tendency of Austenitic Stainless Steel (ASTM C 692-95a) was used to research the effect of halogens and inhibitors on the external stress corrosion cracking (ESCC) of Type 304 stainless steel as it applies to the insulation industry. Simulated insulation extraction solutions were made with pure chemical reagents for the halogens and inhibitors. The results indicated that sodium silicate compounds that were higher in sodium were more effective for preventing chloride-induced ESCC in Type 304 austenitic stainless steel. Potassium silicate was not as effective as sodium silicate. Fluoride, bromide, and iodide may cause ESCC but they were much less active than chloride and could be effectively inhibited by sodium silicate compound. The addition of fluoride ions to the chloride/sodium silicate systems, at the ...

1997-11-01

105

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon ...

2002-04-01

106

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon ...

2002-04-01

107

Antiferromagnetic exchange in a bis(imido) uranium (V) dimeric complex  

Energy Technology Data Exchange (ETDEWEB)

Magnetic coupling between two or more metal centers is an important facet of d- and f-block transition metal chemistry due to its implications in chemical bonding. With respect to actinide metals, magnetic coupling between polymetallic actinide centers is less well-known. Of the few documented examples, only one bimetallic uranium(V) complex, [(MeC{sub 5}H{sub 4}){sub 2}U]{sub 2}[{mu}-1,4-N{sub 2}C{sub 6}H{sub 4}] (1), has unequivocally demonstrated antiferromagnetic coupling. This complex employs a {pi}-conjugated 1,4-phenylenedimide ligand system which bridges the two f{sup 1}-metal centers and enables antiferromagentic coupling between unpaired f-e1ectrons residing in a {pi}-symmetry orbital. In this communication, we report the synthesis of a dimeric bis(imido) uranium(V) iodide complex and demonstrate with magnetic susceptibility measurements and density functional theory (DFT) calculations that the f{sup 1}-uranium centers display antiferromagnetic coupling ...

2008-01-01

108

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...

1990-09-16

109

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM beginning at about 7.5 ...

1998-12-01

110

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

111

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is carried out by FMS ...

2006-11-13

112

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

113

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-15

114

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-01

115

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

116

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...

2004-07-19

117

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

118

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...

1990-11-01

119

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity ...

1995-07-01

120

Radioiodination of 3-quinuclidinyl benzilate using a no-carrier-added concentration of iodine-125/sodium-iodine  

Energy Technology Data Exchange (ETDEWEB)

3-Quinuclidinyl benzilate (QNB) is a potent muscarinic antagonist that binds to muscarinic acetylcholine receptors. Iodination of QNB is difficult because it contains rings that are deactivated, while phenol rings are activated. The purpose of this research is to develop an appropriate method for the iodination of QNB at no-carrier-added concentrations of /sup 125/I/NaI. Phenol was chose as the test compound for direct iodination by adding chloramine T and nonradioactive sodium iodide to the phenol in a phosphate buffer and methanol system. A simple method to radioiodinate QNB at several concentrations was developed in situ in the presence of QNB, thallic trifluoroacetate /sup 125/I/NaI, /sup 127/I/NaI, and aluminium chloride. Using milligram amounts of QNB (7.12 x 10/sup -6/ moles), three reaction steps were involved: QNB was reacted with thallic trifluoroacetate at 60/sup 0/C for 24 hours, then radioactive /sup 125/I/NaI and aluminium chloride were added to the ...

1986-01-01

 
 
 
 
121

Purification of CH{sub 3}Cl from CH{sub 3}I using cold trap with sealed 2,2,4-trimethylpentane for {delta}{sup 37}Cl measurement  

Energy Technology Data Exchange (ETDEWEB)

A cryogenic separation method of chloromethane (CH{sub 3}Cl) from methyl iodide (CH{sub 3}I) for {delta}{sup 37}Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH{sub 3}Cl can be separated from CH{sub 3}I at the TMP melting point (-107 deg. C) based on the difference in the vapor pressure between CH{sub 3}Cl (322.6 Pa) and CH{sub 3}I (lower than 1.3 Pa) at -107 deg. C. After two-step separation processes, the yields of CH{sub 3}Cl purified from CH{sub 3}Cl-CH{sub 3}I mixture are 96-101%, and the difference between the {delta}{sup 37}Cl{sub original} and {delta}{sup 37}Cl{sub Afterseparation} is from -0.06 to +0.06 per mille (0.01 {+-} 0.04 per mille ). These results suggest that CH{sub 3}Cl is completely separated from CH{sub 3}I with no change of {delta}{sup 37}Cl value. This method using the cold trap with sealed TMP is very safe and not harmful, because ...

2006-01-05

122

Preparation of a high specific activity I-125 labeled styryl dye for leukocyte membrane labeling  

International Nuclear Information System (INIS)

The purpose of this work was to develop a high specific activity radioiodinated cell membrane probe for tracking lymphocytes in-vivo to replace the nucleus localizing, cytotoxic lipophilic chelates (In-111 oxine and Tc-99m HMPAO) currently used. Alkylation of parent dye 4-[2-[-N,N-didecylamino]phenyl]ethenyl pyridine with E-1-tributylstannyl-3-tosylpropene (prepared form E-1-tributylstannyl-1-propene-3-ol), gave a tributyltin precursor 1. Radiolabeled 3-[4-[2-[4-(N,N-didecylamino)phenyl]ethenyl]pyridino] E-[I-125]-1-iodopropene (2), was prepared from 1 using peracetic acid in acetonitrile/water. Labeling yields and specific activities achieved were 26% (#approx#2170 Ci/mmol), 40% (1220 Ci/mmol), and 55% (200 Ci/mmol) for nca, 0.4, and 2 nanomole carrier iodide runs respectively. Canine mixed leukocytes (0.5-1.0 x 10"8 cells) were labeled with 2 (67% and 42% yields for 200 Ci/mol and 1220 Ci/mmol preparations) and showed blood clearance similar to In 111 oxine. ...

1994-08-21

123

Incompatibility of metam sodium with halogenated fumigants.  

Science.gov (United States)

Metam sodium (metam) is a widely used soil fumigant. Combined application of metam and other available fumigants is intended to produce synergic pesticidal effects for a broad spectrum of pest control in soil fumigation. This study aimed to test the compatibility of metam with the halogenated fumigants 1,3-dichloropropene (1,3-D), chloropicrin, methyl bromide, methyl iodide and propargyl bromide. Halogenated fumigants and metam were spiked simultaneously into organic solvents, water and moist soils, and metam-induced degradation of these halogenated chemicals was evaluated. In all three media, the halogenated fumigants were incompatible with metam and degraded via rapid chemical reactions. The degradation rate varied with halogenated fumigant species and increased as the amount of metam present was increased. In moist soil, 15-95% of the halogenated fumigants were decomposed within 72 h by metam at a 1:1 molar ratio. Combined application of Telone C-35 (62.5% 1,3-D ...

2005-05-01

124

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT images. The a-Se ...

2004-12-07

125

Luminescent unit computerization to research spectral characteristics of fine film alkali halide crystal  

International Nuclear Information System (INIS)

The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of monochromatic radiation in operating range of each diffraction ...

126

Developments of PET radioligands for NMDA receptors  

International Nuclear Information System (INIS)

Aim: There has been a great demand for developments of the radioligands to visualize the N-methyl-D-aspartate (NMDA) receptors by PET/SPECT. We have recently synthesized two C-11 labeled antagonists for the glycine-binding site on NMDA receptors. The aim of this work is to examine for their in vitro and in vivo binding characteristics, and to evaluate their potentials as PET radioligands for the NMDA receptors. Materials and methods: Two C-11 labeled 4-hydroxy-2-quinolones (1 and 2) were synthesized by conventional methylation of the corresponding phenols with ["1"1C]methyl iodide. In vitro and ex vivo quantitative autoradiographs with imaging plate, as well as animal PET, were employed in order to evaluate their in vitro and in vivo binding to the NMDA receptors. Results: The compound 1 showed the specific binding to rat brain slices with higher localization in the hippocampus and cerebral cortex than in the cerebellum. Both glycine antagonists and agonists ...

2002-09-01

127

(Phospinoalkyl)silyl complexes. 10. Formation of chelated bis[(diphenylphosphinoethyl)diorganosilyl]platinum(II) complexes. Precoordination through phosphorus, intermediacy of a platinum(IV) disilyl, and diastereoisomerism at planar platinum(II) in 'chelate-assisted' hydrosilylation  

Energy Technology Data Exchange (ETDEWEB)

Addition of the silane PPh[sub 2]CH[sub 2]CH[sub 2]SiMe[sub 2]H (chelH, 1a) to Pt(COD)[sub 2] (COD = cycloocta-1,5-diene) affords in high yield the cis-bis chelate Pt(chel)[sub 2] (2); formation of the same product from Pt(COD)(X)Y (X = Y = Me; X = Me, Y = Cl) has been shown by NMR spectroscopy ([sup 1]H, [sup 31]P, [sup 195]Pt) to proceed via prior coordination of chelH through P to afford Pt(chelH)[sub 2](X)(Y) (cis and trans isomers) and through intermediacy of PtH(chel)[sub 2]Cl (22) in which P trans to Si at Pt(IV) leads to an exceptionally low [sup 2]J(Pt-P) = 1084 Hz. Cleavage of Pt-Si bonds in 2 by HCl can be controlled to give the monochelate species Pt(chel)(chelH)Cl (7), from which chelH is displaced by PMe[sub 2]Ph, or trans-PtH(PPh[sub 2]CH[sub 2]SiMe[sub 2]Cl)[sub 2]Cl (9). Products related to 9 result from Pt-Si bond cleavage by I[sub 2] or MeI. Using the analogue PPh[sub 2]CH[sub 2]CH[sub 2]SiMe(Ph)H (1c) of 1a, the analogue Pt-[PPh[sub 2]CH[sub 2]CH[sub 2]SiMe(Ph)][sub ...

1991-08-21