Developments of heavy-ion gas detectors at LNL
Energy Technology Data Exchange (ETDEWEB)
The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.
1984-05-01
International Nuclear Information System (INIS)
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy ...
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon ...
2000-01-01
Segmented focal plane detector for light and heavy ions
Energy Technology Data Exchange (ETDEWEB)
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
1992-06-15
Energy Technology Data Exchange (ETDEWEB)
A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)
1993-10-15
International Nuclear Information System (INIS)
A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).
Bragg curve spectroscopy of fission fragments by using parallel plate avalanche counters
Energy Technology Data Exchange (ETDEWEB)
By using a charge-sensitive preamplifier and methods of energy spectroscopy we investigated the response of a parallel plate avalanche counter in order to scan the Bragg curve. The detector was operated in butane, pentane and heptane which also served as stopping gases. In this paper, we report on results obtained with fission fragments from a /sup 252/Cf source. We achieved a separation of the light and heavy fragment groups in the interval of gas absorber thickness from about 500 ..mu..g cm/sup 2/ to 1.5 mg cm/sup 2/. The best energy loss resolution was achieved with pentane at E/papprox.=70 V cm/sup 1/ Torr/sup 1/ resulting in delta..delta..E/..delta..Eapprox.=13%. The corresponding shape of the ..delta..E spectrum reproduces correctly the nuclear charge distribution of the fragments. (orig.).
1985-07-01
Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies
International Nuclear Information System (INIS)
A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.
New focal plane detector system for the broad range spectrometer
Energy Technology Data Exchange (ETDEWEB)
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
1984-01-01
Focal plane detector for reactions with medium weight projectiles
Energy Technology Data Exchange (ETDEWEB)
A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, ...
1988-12-01
Vacuum ultraviolet radiometry of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...
1995-10-01
Rayleigh Scattering in Rare Gas Liquids
The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.
2002-01-01
International Nuclear Information System (INIS)
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...
1998-06-01
Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam
Energy Technology Data Exchange (ETDEWEB)
Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)
2003-03-01
Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue
Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.
1977-01-01
Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI
International Nuclear Information System (INIS)
The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. ...
2006-11-13
Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode
Energy Technology Data Exchange (ETDEWEB)
Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).
1991-11-15
A time-resolved optical study of the avalanche and streamer formation in atmospheric nitrogen
Energy Technology Data Exchange (ETDEWEB)
This work deals with a time-resolved optical study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen. The authors present the results obtained for nitrogen, from experiments and two-dimensional model simulations. This model is used to obtain a better insight in the relevant mechanisms and processes by a comparison of measurements and simulation data. The trends of externally measured quantities correspond with those predicted by the model.
1996-12-31
Space Radiation Detector with Spherical Geometry
A particle detector is provided, the particle detector including a spherical Cherenkov detector, and
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
SUMMARY We construct a new class of granular landslide models in which avalanches are simulated with large numbers of independent particles moving under the influence of topographically derived gravitational and centripetal acceleration. Concurrently, the particles suffer deceleration due to basal and dynamic friction. The novel aspect of the calculation is that complex particle-to-particle interactions, fluctuating basal contacts, and unresolved topographic roughness within and below the deforming flow are mimicked by random perturbations in along-track and cross-slope acceleration. We apply the method to the 1980 May 18 Mount Saint Helens debris avalanche by constraining the initial geometry and structure of the slide mass from geological data, and the initial failure sequence from eyewi...
2006-01-01
Effects of avalanche hole injection in fluorinated SiO[sub 2] MOS capacitors
Energy Technology Data Exchange (ETDEWEB)
Significantly improved immunity to hot-hole damage of the SiO[sub 2]/Si structure is achieved by a shallow fluorine implantation into the poly-Si gate of MOS capacitors followed by a drive-in process. Compared to the nonfluorinated control, the fluorinated samples exhibit a dramatic reduction of both hole trapping probability and interface-trap generation under avalanche hole injection conditions. The degree of such an improvement increases monotonically as a function of the F implantation dose (up to 10[sup 16]/cm[sup 2]). Significant decrease of the hole detrapping rate is also observed in fluorinated samples. Possible mechanisms are discussed.
1993-04-01
Radial distribution of bonded fission gas in mixed carbide fuel pins
International Nuclear Information System (INIS)
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
1979-01-01
British Library Electronic Table of Contents (United Kingdom)
We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.
1988-07-01
International Nuclear Information System (INIS)
A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.
VUV efficiency and radiant emittance characterization of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...
1996-12-31
Mercury-free fluorescent lighting
Energy Technology Data Exchange (ETDEWEB)
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...
1996-05-01
Formation of streamers in nitrogen and dry air; Vorming van streamers in stikstof en lucht
Energy Technology Data Exchange (ETDEWEB)
The results of a time-resolved study of the avalanche and streamer formation phases leading to breakdown in atmospheric nitrogen and dry air. Results of experiments and two-dimensional simulations are presented. It is shown what processes are responsible for the formation of a streamer. The trends of externally measured quantities correspond with those predicted by our model. 3 figs., 5 refs.
1997-01-01
Bistability and hysteresis in tilted sandpiles
We show that tilting a model sandpile that has dynamic disorder leads to bistability and hysteresis at the angle of repose. Also the distribution of {\\it local slopes} shows an interesting dependence on the amount of tilt - weakly tilted sandpiles retain the quasi-continuous distributions of the steady state, while large tilt makes the distribution more discrete, with local slopes clustered round particular values. These observations are used to explain recent experimental results on avalanche shapes; we give a theoretical framework in terms of directed percolation.
2000-01-01
A multi-megawatt X-band solid state microwave switch
Energy Technology Data Exchange (ETDEWEB)
The authors present design methodology and initial experimental results for a high power microwave switch. The switch is designed for application to the pulse compression system associated with the Next Linear Collider Test Accelerator (NLCTA). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. They explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission.
1995-12-31
Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty
Energy Technology Data Exchange (ETDEWEB)
Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...
1996-06-01
Total cross sections of ultracold neutron interactions with some gases
Energy Technology Data Exchange (ETDEWEB)
Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.
1981-11-01
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
International Nuclear Information System (INIS)
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
Plasma diagnostics by spectra from LHD and atomic data
International Nuclear Information System (INIS)
We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)
2009-04-01
Transport characteristics of dehydrogenated ammonia borane and sodium borohydride spent fuels
Energy Technology Data Exchange (ETDEWEB)
Ammonia borane (AB) and sodium borohydride (SBH) are candidate materials for on-board hydrogen storage that can be dehydrogenated upon demand. The rheological properties of the dehydrogenated by-products are important to quantify their removal and transportability from the hydrogen storage system. This paper presents visco-elastic property (elastic stiffness and viscous damping) measurements of the spent fuels obtained from AB hydrolysis, hydrothermolysis and thermolysis; and SBH hydrolysis. Smaller stiffness and larger mobility (or smaller viscous damping) indicate better transportability of the spent fuel. In addition, flow property (dynamic angle of repose and avalanching time) measurements for the hydrolysis spent fuels of AB and SBH are also presented. Comparing with the SBH hydrolysis spent fuel, the AB hydrolysis spent fuel had a lower stiffness and larger mobility, as well as lower angles of dynamic repose and avalanche power peaks, ...
2010-03-15
Design of a multi-megawatt x-band solid state microwave switch
Energy Technology Data Exchange (ETDEWEB)
The authors present design methodology for high power microwave switches. Among all possible applications for such a switch they emphasize the design parameters for application to the pulse compression system associated with the Next Linear Collider (NLC). The switch is based on the excitation of a plasma layer within a silicon wafer by either a laser or an electron beam. They investigate problems associated with high power operation of such a switch. Mainly, they explore solutions to the problems of thermal runaway, avalanche breakdown, photo-emission, and secondary emission. Different design methodologies are presented.
1995-07-01
Radiant emittance of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...
1994-12-31
Monitoring for Xenon Radionuclides and CTBT Verification
International Nuclear Information System (INIS)
The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.
1983-01-01
Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer
Energy Technology Data Exchange (ETDEWEB)
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
1991-05-08
Energy Technology Data Exchange (ETDEWEB)
To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design
2006-12-04
Small world when building a particle detector prototype, the devil is in the tiny details
Small world when building a particle detector prototype, the devil is in the tiny details
2004-01-01
Photodiode Scintillation Detector for Anti-Coincidence Shielding
Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...
Operational reactor physics analysis codes (ORPAC)
International Nuclear Information System (INIS)
Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...
Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen
International Nuclear Information System (INIS)
For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.
2009-11-01
Energy Technology Data Exchange (ETDEWEB)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
1993-12-01
Bragg curve spectroscopy detector for particle identification
International Nuclear Information System (INIS)
The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.
International Nuclear Information System (INIS)
We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...
Energy Technology Data Exchange (ETDEWEB)
Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.
1988-07-01
International Nuclear Information System (INIS)
Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...
Using Genetic Algorithms for Texts Classification Problems
The avalanche quantity of the information developed by mankind has led to concept of automation of knowledge extraction - Data Mining ([1]). This direction is connected with a wide spectrum of problems - from recognition of the fuzzy set to creation of search machines. Important component of Data Mining is processing of the text information. Such problems lean on concept of classification and clustering ([2]). Classification consists in definition of an accessory of some element (text) to one of in advance created classes. Clustering means splitting a set of elements (texts) on clusters which quantity are defined by localization of elements of the given set in vicinities of these some natural centers of these clusters. Realization of a problem of classification initially should lean on the given postulates, basic of which - the aprioristic information on primary set of texts and a measure of affinity of elements and classes.
2009-01-01
International Nuclear Information System (INIS)
This article describes the laser Thomson scattering principle and the developed system on HL-2A device. The high power Q-switch Nd:YAG laser, with a wavelength of 1064 nm, can sufficiently satisfy the measurement requirement. The polycromator consisting of avalanche photo-diodes(APD) and narrow band interference filters, can effectively improve the measurement of scattering light. The electron temperature is deduced by error-weighted lookup table method, which improves the data- processing speed or efficiency. Finally, the experiment results of the one-point electron temperature during different discharges of plasma are presented. (authors)
2008-07-01
This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.
2007-08-01
International Nuclear Information System (INIS)
This paper discusses the mechanisms of gas breakdown at low values of pressure and inter-electrode gap, i.e. in the vicinity of the Paschen minimum. In this area of pressure and inter-electrode gap values, breakdown occurs either through gas or vacuum mechanisms, and also the so called anomalous Paschen effect appears. Electrical breakdown of electropositive, electronegative and noble gases has been investigated theoretically, experimentally and numerically. Based on the results obtained, regions in which particular breakdown mechanisms appear have been demarcated. Special attention has been devoted to the anomalous Paschen effect as well as to the avalanche vacuum breakdown mechanism.
2007-08-01
Extragalactic Planetary Nebulae: Observational Challenges & Future Prospects
The study of extragalactic planetary nebulae (EPN) is a rapidly expanding field. The advent of powerful new instrumentation such as the PN spectrograph has led to an avalanche of new EPN discoveries both within and between galaxies. We now have thousands of EPN detections in a heterogeneous selection of nearby galaxies and their local environments, dwarfing the combined galactic detection efforts of the last century. Key scientific motivations driving this rapid growth in EPN research and discovery have been the use of the PNLF as a standard candle, as dynamical tracers of their host galaxies and dark matter and as probes of Galactic evolution. This is coupled with the basic utility of PN as laboratories of nebula physics and the consequent comparison with theory where population differences, abundance variations and star formation history within and between stellar systems informs both stellar and galactic evolution. Here we pose some of the burning questions, ...
2004-01-01
A novel EPROM device fabricated using focused boron ion-beam implantation
Energy Technology Data Exchange (ETDEWEB)
A novel floating-gate avalanche injection (FAMOS) type erasable programmable read-only memory (EPROM) device is demonstrated, with a heavily focused ion-beam (FIB) implanted region of about 0.2-..mu..m width at the drain edge of the channel. This heavily B/sup +/-doped region permits a higher electric field near the drain edge, resulting in a remarkable increase of the hot-carrier generation rate, and reduces both the programming voltage and programming time. A three-dimensional device simulator, CADDETH, predicted that the electric field at the drain edge would increase by about six times, which would lead to hot-carrier generation efficiency three orders of magnitude higher.
1987-06-01
Recovery of cesium in the hydrogen negative ion sources
Energy Technology Data Exchange (ETDEWEB)
Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)
1999-12-01
Breached fuel location in FFTF by delayed neutron monitor triangulation
International Nuclear Information System (INIS)
The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.
1985-11-10
Energy Technology Data Exchange (ETDEWEB)
Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.
1993-07-01
A NEM diffusion code for fuel management and time average core calculation
International Nuclear Information System (INIS)
A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)
2005-11-01
Use of gadolinium as neutron poison in 540 MWe PHWR
International Nuclear Information System (INIS)
In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...
2006-11-13
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.
2010-01-01
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
First results from the Lund NMP particle detector system
International Nuclear Information System (INIS)
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
2009-06-15
First results from the Lund NMP particle detector system
British Library Electronic Table of Contents (United Kingdom)
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
2009-01-01
Femtosecond Laser Passivation of GaAs Detector Material
... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...
2008-06-07
Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector
Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector
1993-01-01
A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...
2003-03-04
Verification of lithium detector efficiency using DD neutron
International Nuclear Information System (INIS)
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
2005-08-01
Use of signal delay of one of detectors in two-channel radiometric flaw detector
International Nuclear Information System (INIS)
A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.
Resonant-mass detectors of gravitational radiation
International Nuclear Information System (INIS)
A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.
1987-07-01
Presentation of random process at the output of a scintillation detector
International Nuclear Information System (INIS)
(1973). USSR Ovcharenko, AM Nedavnij, OI Kapranov, BI Tomskij
The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.
1999-01-01
Application of Pd silicide in the process of silicon detectors
Energy Technology Data Exchange (ETDEWEB)
A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.
1990-04-01
radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...
Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys
Energy Technology Data Exchange (ETDEWEB)
Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)
2001-05-16
Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.
1995-08-01
Development of a small scintillation detector with an optical fiber for fast neutrons
International Nuclear Information System (INIS)
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...
2011-02-01
Design and fabrication of large ultra-thin PIN detector with membrane stress deviation
Energy Technology Data Exchange (ETDEWEB)
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.
2010-09-15
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
Core simulations using actual detector readings for a Canada deuterium uranium reactor
This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.
1991-02-01
A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)
1958-05-01
Thermal degradation of wood during photodegradation
British Library Electronic Table of Contents (United Kingdom)
In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...
2011-01-01
Striatal dysfunction in attention deficit and hyperkinetic disorder
Energy Technology Data Exchange (ETDEWEB)
We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)
2010-07-15
Laser application in the fabrication of gas-tagged capsules. A leak detection system
Energy Technology Data Exchange (ETDEWEB)
Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.
1993-12-01
Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects
Energy Technology Data Exchange (ETDEWEB)
By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.
1985-01-11
We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...
2007-01-01
Large-scale structure of a nation-wide production network
Production in economy is a set of firms' activities as suppliers and customers; a firm buys goods from other firms, puts added-values and sells products to others in a giant network of production. Empirical study has been lacking despite of the fact that the structure of production network is important to understand and make models for many aspects of dynamics in economy. We study a nation-wide production network comprising a million of firms and millions of supplier-customer links by using recent statistical methods developed in physics. We show in the empirical analysis scale-free degree distribution, disassortativity, correlation of degree to firm-size, and community structure having sectoral and regional modules. Since suppliers usually provide credit to their customers, who supply to theirs in turn, each link is actually a creditor-debtor relation. We also study chains of failures or bankruptcies that take place along those links in the network, and the ...
2008-01-01
A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the ...
1990-03-01
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...
2008-05-24
Cerebral blood flow measurement using stable xenon CT with very short inhalation times
Energy Technology Data Exchange (ETDEWEB)
A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...
1991-02-01
Cerebral blood flow measurement using stable xenon CT with very short inhalation times
International Nuclear Information System (INIS)
A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...
UK PubMed Central (United Kingdom)
An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available
2009-12-15
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...
1991-03-13
Conventional detectors for a photon-photon collider
Energy Technology Data Exchange (ETDEWEB)
Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).
1995-02-01
UK PubMed Central (United Kingdom)
We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available
2010-01-01
UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors
International Nuclear Information System (INIS)
(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,
1978-06-18
The virtual fast-ion loss detector
International Nuclear Information System (INIS)
English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.
2009-09-21
Radionuclide X-ray fluorescence analysis using semiconductor detectors
International Nuclear Information System (INIS)
Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav
1979-05-01
Parameter optimization of a planar BEGe detector using Monte Carlo simulations
International Nuclear Information System (INIS)
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
2010-11-21
Method and system for detecting explosives
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2009-03-10
GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector
We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon
2007-01-01
Explosives detection system and method
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2007-12-11
Detection threshold for alpha-particles on the solid-state track detector of celluloid films
International Nuclear Information System (INIS)
(Apr 1974). Japan Murakami, Akira . Saga Univ. (Japan). Dept. of
CMS Silicon Strip Tracker Performance
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
2011-01-01
Advances in imaging THGEM-based detectors
International Nuclear Information System (INIS)
We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).
1991-01-01
Using neutron-activation detectors with fissionable nuclides
Energy Technology Data Exchange (ETDEWEB)
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
1986-09-01
Test of superconducting Nb/Al bilayers as particle detectors
Energy Technology Data Exchange (ETDEWEB)
Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.
2000-04-07
Position detector design using an electrostatic application of ANSYS[sup TM
Energy Technology Data Exchange (ETDEWEB)
The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.
1994-10-10
Performance of CDF calorimeter simulation for Tevatron Run II
Energy Technology Data Exchange (ETDEWEB)
The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.
2002-09-19
Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Fundamental understanding of aging processes Review of the workshop results
A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.
2003-01-01
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
A comparison of x-ray detectors for mouse CT imaging
International Nuclear Information System (INIS)
There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...
2004-12-07
Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration
Energy Technology Data Exchange (ETDEWEB)
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...
2009-07-23
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
1996-01-01
International Nuclear Information System (INIS)
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
2006-11-13
Calibration of solid state nuclear track detector CR-39 for radon measurements
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
2007-07-01
Calibration of solid state nuclear track detector CR-39 for radon measurements
International Nuclear Information System (INIS)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
A new method of imaging particle tracks in solid state nuclear track detectors
British Library Electronic Table of Contents (United Kingdom)
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
2010-01-01
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...
1991-09-01
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
International Nuclear Information System (INIS)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...
A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector
British Library Electronic Table of Contents (United Kingdom)
An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...
2007-01-01
A Detector for 2-D Neutron Imaging for the Spallation Neutron Source
Energy Technology Data Exchange (ETDEWEB)
Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...
1985-03-01
Large area, low capacitance Si(Li) detectors for high rate x-ray applications
Energy Technology Data Exchange (ETDEWEB)
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...
1992-10-01
Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors
This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...
2004-01-01
Photoelectrochemistry of disordered passive films
Energy Technology Data Exchange (ETDEWEB)
A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...
1987-01-01
In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...
2004-08-31
Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration
Energy Technology Data Exchange (ETDEWEB)
A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...
1995-12-31
Design and safety evaluation of radioactive gas handling and storage in the FFTF
International Nuclear Information System (INIS)
During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...
1976-06-13
Clinical application of stable xenon CT-CBF studies without denitrogenation
Energy Technology Data Exchange (ETDEWEB)
Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...
1990-08-01
Clinical application of stable xenon CT-CBF studies without denitrogenation
International Nuclear Information System (INIS)
Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...
Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector
Energy Technology Data Exchange (ETDEWEB)
The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...
2006-07-01
Physics of the {sup 252}Cf-source-driven noise analysis measurement
Energy Technology Data Exchange (ETDEWEB)
The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...
1997-02-01
Electronics for the Si detectors in APEX
Energy Technology Data Exchange (ETDEWEB)
APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...
1994-07-01
Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode
International Nuclear Information System (INIS)
This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...
Characterization of 3D thermal neutron semiconductor detectors
International Nuclear Information System (INIS)
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...
2007-06-11
The hunt for ?13 at the Daya Bay nuclear power plant
International Nuclear Information System (INIS)
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
2010-03-30
The cross-coupled interferometer for gravitational wave detection
International Nuclear Information System (INIS)
The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.
2002-04-07
International Nuclear Information System (INIS)
We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.
2004-03-07
International Nuclear Information System (INIS)
The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.
Studies of a Poenitz-type black neutron detector as a neutron flux monitor
Energy Technology Data Exchange (ETDEWEB)
A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).
1997-04-01
Silicon Detector Letter of Intent
Energy Technology Data Exchange (ETDEWEB)
This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.
2010-05-26
Nuclear borehole logging using lithium detector assemblies
International Nuclear Information System (INIS)
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
1991-05-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
International Nuclear Information System (INIS)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A PDA-Based ECG Beat Detector for Home Cardiac Care.
Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192
2005-01-01
View Record - NASA Jet Propulsion Laboratory
Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...
The mass dependence of the signal peak height of a Bragg-curve ionization chamber
International Nuclear Information System (INIS)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).
The CDF intermediate silicon layers detector
Energy Technology Data Exchange (ETDEWEB)
The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.
1999-11-01
The Brazilian Bragg curve detector built for AMS studies
Energy Technology Data Exchange (ETDEWEB)
A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.
2000-10-01
Studies of relativistic heavy ion collisions at the AGS (Experiment 814)
Energy Technology Data Exchange (ETDEWEB)
This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)
1990-01-01
The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...
2001-01-01
Space Images - NASA Jet Propulsion Laboratory
Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...
Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information
International Nuclear Information System (INIS)
The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)
2010-11-01
Radon concentration measurements by means of nuclear tracks detector with image analysis
International Nuclear Information System (INIS)
English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,
1998-09-15
Photoconductive ultraviolet detectors based on ZnO films
British Library Electronic Table of Contents (United Kingdom)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...
2006-01-01
Particle identification for heavy ions in a time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
1982-05-01
PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.
Energy Technology Data Exchange (ETDEWEB)
We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...
2006-10-29
International Nuclear Information System (INIS)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
Optimal detector deployment for the CANDU-600 pressurized heavy water reactor
An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...
1992-01-01
Mass dependence of the signal peak height of a Bragg-curve ionization chamber
Energy Technology Data Exchange (ETDEWEB)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.
1985-01-01
Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors
International Nuclear Information System (INIS)
The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.
2004-03-07
LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA
Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...
Intercomparison of Retrospective Radon Detectors
Energy Technology Data Exchange (ETDEWEB)
We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...
1998-11-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...
2006-11-13
Development of a new #gamma#-ray detector for PEM applications
International Nuclear Information System (INIS)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
2007-05-01
Energy Technology Data Exchange (ETDEWEB)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-15
International Nuclear Information System (INIS)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA
FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...
Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid
In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
1993-12-31
International Nuclear Information System (INIS)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
Change of the DKPS-100 semiconductor detector properties under 3.2 MeV alpha particle irradiation
International Nuclear Information System (INIS)
Russian 1977. p. 582. USSR Antropov, AE Fedoseeva, OP Milovanov,
International Nuclear Information System (INIS)
Polish 2001 p. 105 Poland Bogacz, J. Budzanowski, M. Mazur, J. Swakon,
2001-09-10
Annihilation of antiprotons in light nuclei
CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.
2006-01-01
AeroSpace Information for a Changing World - NASA Technical ...
Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...
A real-time neutron dosimeter for high energy neutrons with an Si surface barrier detector
International Nuclear Information System (INIS)
1982. p. 173-175. Israel Eisen, Y. Engler, G. Ovadia, E. Shamai, Y. Israel
1982-12-14
A Quantum-Enhanced Prototype Gravitational-Wave Detector
The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...
2008-01-01
8 - NASA Technical Report Server (NTRS)
feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...
Seafloor mapping and morphometric analysis of landslide scars can provide useful insights for marine geo-hazard assessment, as demonstrated by several studies performed on different geological settings. The availability of high-resolution multibeam bathymetry and long-range side scan sonar data on the submarine portions of Stromboli Volcano allow us to map and characterize the main mass-wasting features that affect, on the whole, about the 90% of its submarine extension. In particular, two main kinds of tsunamigenic landslides have been recognized and analyzed. Large-scale sector collapses (Fig. 1) are catastrophic events that mobilize 1-2 cubic kilometers of material, generating huge tsunami waves that may affect Stromboli and propagate in surrounding areas; related hazard is not very high, as they show recurrence periods of some (or more) thousand years. Conversely, medium-scale landslides are more hazardous, as they occur at higher frequency with respect to the previous events, i.e. ...
2010-12-01
Study on reactivity measurement by the Feynman-#alpha# method
International Nuclear Information System (INIS)
The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).
1996-09-01
Si(111)/Gd: A fast and high-resolution thermal neutron detector
Energy Technology Data Exchange (ETDEWEB)
Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
1993-01-01
Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy
Energy Technology Data Exchange (ETDEWEB)
We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.
1995-04-13
Radon concentration measurements in the soil
International Nuclear Information System (INIS)
Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)
Proposed high-resolution vertex detector using superconductive thin strips
Energy Technology Data Exchange (ETDEWEB)
The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.
1984-06-01
Portable real time neutron spectrometry II
International Nuclear Information System (INIS)
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
2000-01-19
Portable real time neutron spectrometry
International Nuclear Information System (INIS)
We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.
1999-01-22
Performance of the transition radiation detector in D{Phi}
Energy Technology Data Exchange (ETDEWEB)
The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.
1994-12-31
Performance of a large Bragg-curve spectrometer
Energy Technology Data Exchange (ETDEWEB)
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.
1987-04-01
Performance of a large Bragg-curve spectrometer
International Nuclear Information System (INIS)
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Multi-spectral schottky barrier infrared radiation detection array
Energy Technology Data Exchange (ETDEWEB)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
1983-12-27
Multi-spectral schottky barrier infrared radiation detection array
International Nuclear Information System (INIS)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
Medical explorations by radioisotopes in Lebanon
International Nuclear Information System (INIS)
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity
Energy Technology Data Exchange (ETDEWEB)
In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).
1995-02-01
Gamma ray detecting device using dislocation-free crystal
Energy Technology Data Exchange (ETDEWEB)
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
1991-04-30
GaAs detector optimization for different medical imaging applications
International Nuclear Information System (INIS)
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
1999-09-11
First tests of "bulk" MICROMEGAS with resistive cathode mesh
We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.
2010-01-01
Explosives detection: the problem and prospects
Energy Technology Data Exchange (ETDEWEB)
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
1984-01-01
Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector
International Nuclear Information System (INIS)
The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).
1993-12-02
Development of a real-time, neutron and gamma dosimeter
Energy Technology Data Exchange (ETDEWEB)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-07-01
Development of a real-time, neutron and gamma dosimeter
International Nuclear Information System (INIS)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-06-10
Determination of reactor kinetic parameters in a two-core reactor
Energy Technology Data Exchange (ETDEWEB)
The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.
1982-01-01
Detector questions for a gamma-gamma collider
Energy Technology Data Exchange (ETDEWEB)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
1995-02-01
Detector questions for a gamma-gamma collider
International Nuclear Information System (INIS)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
Detection device for high explosives
Energy Technology Data Exchange (ETDEWEB)
A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.
1992-01-01
A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.
2006-05-16
CPA simulator: A software tool to simulate nuclear front-end circuit response
International Nuclear Information System (INIS)
A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.
2010-12-21
Assessment of detector sensitivity and uniformity during SPECT rotation
International Nuclear Information System (INIS)
The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...
1984-06-05
Applications of Bonner sphere detectors in neutron field dosimetry
Energy Technology Data Exchange (ETDEWEB)
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
1983-09-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...
2005-11-23
An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy
Energy Technology Data Exchange (ETDEWEB)
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...
1995-11-01
International Nuclear Information System (INIS)
Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).
A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode
Energy Technology Data Exchange (ETDEWEB)
A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))
1994-07-15
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Recent Progress in CdTe and CdZnTe Detectors
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...
2001-01-01
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended ...
2004-12-21
Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry
A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an ...
2002-01-01
Design and implementation of the BESIII detector-control system
Energy Technology Data Exchange (ETDEWEB)
In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...
2008-07-21
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. ...
2005-10-23
Energy Technology Data Exchange (ETDEWEB)
In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...
1997-05-01
A large surface neutron and photon detector for civil security applications
Energy Technology Data Exchange (ETDEWEB)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-21
A large surface neutron and photon detector for civil security applications
International Nuclear Information System (INIS)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-11
Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films
British Library Electronic Table of Contents (United Kingdom)
Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.
2008-01-01
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
Status of combined point source search with neutrino telescopes IceCube and AMANDA
Energy Technology Data Exchange (ETDEWEB)
In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.
2010-07-01
Spatial distribution of IGC-30 Ge-detector's efficiency
International Nuclear Information System (INIS)
The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).
1993-12-02
Some considerations about future interferometric GW detectors
International Nuclear Information System (INIS)
The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.
2004-03-07
Quartz fiber calorimetry and calorimeters
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.
2004-01-01
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Particle and X-ray damage in pn-CCDs
Energy Technology Data Exchange (ETDEWEB)
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
2000-01-11
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Magnetic beam position monitor
Energy Technology Data Exchange (ETDEWEB)
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...
1995-12-31
Ion beam induced charge imaging of epitaxial GaN detectors
Energy Technology Data Exchange (ETDEWEB)
We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.
2004-09-21
Energy Technology Data Exchange (ETDEWEB)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
1991-01-01
International Nuclear Information System (INIS)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
British Library Electronic Table of Contents (United Kingdom)
Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...
2010-01-01
High Energy Neutrino Telescopes
This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.
2008-01-01
Feasibility study of the iterative x-ray phase retrieval algorithm
International Nuclear Information System (INIS)
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
2009-01-01
Cooling device for impurity removal device in thermonuclear devices
International Nuclear Information System (INIS)
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
1983-08-26
Aging measurements of a TMAE-based photon detector for the HERA-B RICH
We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...
2009-01-01
International Nuclear Information System (INIS)
Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...
Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)
Energy Technology Data Exchange (ETDEWEB)
Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...
2006-06-15
Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)
International Nuclear Information System (INIS)
Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...
2006-06-01
Energy Technology Data Exchange (ETDEWEB)
An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...
1993-12-31
Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen
International Nuclear Information System (INIS)
Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...
2004-07-19
Energy Technology Data Exchange (ETDEWEB)
The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...
1990-11-01
Using Military Working Dog Teams (MWDTs) to Support Law ...
... 4. Military Working Dogs iMWDs). As used in this Instruction refers to drug detector dogs only. 5. Military Working Doq Executive Agent M(WJDEMA. ...
1990-09-17
Use of solid state nuclear track detectors for radon concentration measurements indoors
International Nuclear Information System (INIS)
An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
UK PubMed Central (United Kingdom)
BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available
The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...
2009-01-01
The Development of a Neutral Particle Detector for Observations of the Thermosphere
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight ...
2006-12-01
Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector
UK PubMed Central (United Kingdom)
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.
1982-01-01
Research in heavy-ion nuclear physics
Energy Technology Data Exchange (ETDEWEB)
This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.
1992-01-01
Radon concentration measurement in dwellings in Belgrade
International Nuclear Information System (INIS)
The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).
Post-column reaction detector for platinum(II) antieoplastic agents
Energy Technology Data Exchange (ETDEWEB)
The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) ...
1984-03-01
Photoconductive ultraviolet detectors based on ZnO films
Energy Technology Data Exchange (ETDEWEB)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...
2006-12-15
Photoconductive ultraviolet detectors based on ZnO films
International Nuclear Information System (INIS)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...
2006-12-15
Energy Technology Data Exchange (ETDEWEB)
GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
1997-12-31
International Nuclear Information System (INIS)
GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
1996-12-02
Performance assessment for EEG-based neonatal seizure detectors
UK PubMed Central (United Kingdom)
ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available
2011-03-01
Optical Modelling of the HFI Instrument on Board the Planck Surveyor
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...
1999-07-01
Online processing in the ALICE DAQ The detector algorithms
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
2010-01-01
On-line real-time measurements of decontamination factor for a low-level waste incinerator
Energy Technology Data Exchange (ETDEWEB)
The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.
1983-01-01
On-line real-time measurements of decontamination factor for a low-level waste incinerator
International Nuclear Information System (INIS)
The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.
Novel remote sensing gas outburst detector
Energy Technology Data Exchange (ETDEWEB)
The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.
1984-08-01
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces
We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 ...
2006-07-01
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation ...
2007-08-21
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
MAGIC - Multi Anode Gas Ionization Chamber
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))
1994-12-01
Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences
The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)
1973-08-01
Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982
Energy Technology Data Exchange (ETDEWEB)
Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...
1982-12-01
Indoor radon concentration measurements by using SSNTD
International Nuclear Information System (INIS)
In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.
Indoor radon concentration measurements
International Nuclear Information System (INIS)
Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).
Front-End-Electronics Communication software for multiple detectors in the ALICE experiment
Energy Technology Data Exchange (ETDEWEB)
In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...
2006-02-15
Forschungszentrum Juelich, Institut fuer Kernphysik/COSY. Annual report 2004
Energy Technology Data Exchange (ETDEWEB)
The following topics are dealt with: Detectors at COSY, major physics results at COSY, physics at external facilities, theoretical investigations, COSY operation and developments, preparations for FAIR, technical developments. (HSI)
2005-03-01
Feynmann variance-to-mean method
Energy Technology Data Exchange (ETDEWEB)
The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.
1985-01-01
Explosives detection The problem and prospects
Energy Technology Data Exchange (ETDEWEB)
Explosives molecules have a number of unique properties. These properties are discussed. They include low vapor pressures, electronegativity, ''stickiness,'' frangibility, and thermal instability. The program for developing an advanced explosives detector is described.
1984-07-01
UK PubMed Central (United Kingdom)
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
2008-01-01
Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?
Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give ...
2004-01-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
Energy Technology Data Exchange (ETDEWEB)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...
2002-04-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
International Nuclear Information System (INIS)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...
2002-04-01
The Daya Bay Neutrino Experiment is proposed to measure sin^2(2\\theta_{13}) to better than 0.01 at 90% C.L. in a three-year run. The experimental site, detector design, and background estimation are presented.
2006-01-01
International Nuclear Information System (INIS)
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The ...
1992-03-16
International Nuclear Information System (INIS)
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to ...
2009-06-07
Boron-Lined Neutron Detector Measurements
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined ...
2009-11-02
Black holes as detectors of tachyons
International Nuclear Information System (INIS)
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Angular sensitivity distribution of detectors for BNCT
Energy Technology Data Exchange (ETDEWEB)
The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...
1995-03-01
Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications
Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.
2007-01-01
Response of track-etch dosemeters to environmental radon
Energy Technology Data Exchange (ETDEWEB)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
1988-01-01
Real time neutron dosemeter response calculations
International Nuclear Information System (INIS)
The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).
1996-04-01
Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia
Energy Technology Data Exchange (ETDEWEB)
Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...
2006-07-01
Proceedings of the technical exchange meeting on passive radon monnitoring
International Nuclear Information System (INIS)
The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.
1987-09-21
Positron-Electron Pair Creation Near Threshold
Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.
2009-01-28
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)
Energy Technology Data Exchange (ETDEWEB)
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
1993-01-01
Measurement of the inclusive Z production cross section with the CMS detector
First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.
2010-01-01
Forward Physics with the CMS experiment at the Large Hadron Collider
multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15
2010-01-01
Daya Bay reactor anti-neutrino experiment
International Nuclear Information System (INIS)
The Daya Bay Reactor Anti-Neutrino Experiment is a neutrino oscillation experiment designed to observe and measure the neutrino mixing angle ?13. The sensitivity goal is 0.01 in sin 22?13 at the 90% confidence level, a significant improvement over the current limit. This will be accomplished by measuring the relative rates and energy spectra of reactor electron antineutrinos with multiple detectors positioned at different baselines. Civil construction is currently under-way as detector designs and planning near completion. Commissioning activities should be completed by the end of 2010, followed by a three-year run.
2008-11-01
Daya Bay Neutrino Experiment: Goal, Progress and Schedule
Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.
2011-01-01
Conceptual design of the ATLAS EM muon chamber support structures
The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.
1998-01-01
Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment
International Nuclear Information System (INIS)
This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)
2006-10-21
Application of proportional counters in Polish medicine and agriculture
Energy Technology Data Exchange (ETDEWEB)
In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.
1996-12-31
Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
2011-09-01
A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
1994-09-01
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
A 40 GByte/s read-out system for GEM
Energy Technology Data Exchange (ETDEWEB)
The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.
1994-04-01
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and ...
2000-08-07
Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys
International Nuclear Information System (INIS)
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with ...
2000-08-07
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...
1988-08-01
Temperature dependence of the performance of ultraviolet detectors
Energy Technology Data Exchange (ETDEWEB)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...
2003-08-21
Temperature dependence of the performance of ultraviolet detectors
International Nuclear Information System (INIS)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the ...
2003-08-21
Energy Technology Data Exchange (ETDEWEB)
The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which ...
1986-01-01
International Nuclear Information System (INIS)
An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near critical by an ...
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...
1993-10-13
HALO - the helium and lead observatory for supernova neutrinos
Energy Technology Data Exchange (ETDEWEB)
The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron ...
2008-11-01
Considerations for the next Compton telescope mission
International Nuclear Information System (INIS)
A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo ...
2000-04-12
Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional ...
2010-09-07
Basic study of entire whole-body PET scanners based on the OpenPET geometry
International Nuclear Information System (INIS)
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, ...
2010-09-01
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.
2007-01-01
Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft
Energy Technology Data Exchange (ETDEWEB)
A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...
2004-10-13
TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams
International Nuclear Information System (INIS)
A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...
2010-03-11
We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless double $\\beta$-decay and ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.
1992-01-01
Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993
Energy Technology Data Exchange (ETDEWEB)
Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.
1992-01-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...
1989-06-01
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...
1992-10-25
National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards
International Nuclear Information System (INIS)
As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...
2009-12-16
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...
2004-03-09
MicroDiffraction in the Scanning Electron Microscope (SEM)
The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification ...
1997-12-31
Micro-strip metal foil detectors for the beam profile monitoring
Energy Technology Data Exchange (ETDEWEB)
The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)
2005-11-15
Launch of the Space experiment PAMELA
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In ...
2007-01-01
Investigation of the frequency-dependence of the MTC noise estimator
International Nuclear Information System (INIS)
The Moderator Temperature Coefficient of reactivity (MTC) was earlier proven to be properly determined via noise analysis when the neutron noise is measured locally and when the radial average of the moderator temperature noise is used. Nevertheless, measurements revealed that the MTC was correctly estimated on a much narrower frequency band (0.6 - 0.7 Hz) than expected (0.1 - 1.0 Hz). The present paper investigates the effect of the feedback on the MTC determination using this new MTC noise estimator (which could explain the deviation at low frequencies, i.e. between 0.1 - 0.5 Hz) and the effect of the detector time constants (which could explain the deviation at high frequencies, i.e. between 0.7 - 1.0 Hz). For that purpose, a coupled neutronic/thermalhydraulic model of the Ringhals-3 PWR is developed in the frequency-domain, based on a radial 2-dimensional heterogeneous representation of the core. The transfer function of the detectors is ...
2005-09-12
Interim cryo-cooler/detector report
Energy Technology Data Exchange (ETDEWEB)
This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...
1995-04-19
Energy Technology Data Exchange (ETDEWEB)
Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in relation with the ...
2010-11-15
International Nuclear Information System (INIS)
In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...
1990-10-29
Edge filter and fringe imaging for laser Doppler wind speed measurement
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of ...
1997-08-01
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate between the neutron events ...
1997-07-01
Construction and Calibration of the Laser Alignment System for the CMS Tracker
The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) ...
2006-01-01
International Nuclear Information System (INIS)
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)
2011-01-01
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...
2005-01-01
Application of a finite element method to leak before break (LBB) of a heat exchanger
International Nuclear Information System (INIS)
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat ...
2003-08-17
Accelerator related background in the CMS detector at LHC
International Nuclear Information System (INIS)
Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of accelerator ...
A Risk-Based Sensor Placement Methodology
Energy Technology Data Exchange (ETDEWEB)
A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal ...
2008-10-01
Pre-Flight Development of the PoGOLite Pathfinder
International Nuclear Information System (INIS)
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...
Energy Technology Data Exchange (ETDEWEB)
The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.
1995-09-01
The BAIKAL Neutrino Experiment: From NT200 to NT200+
The Baikal Neutrino Telescope has been operating in its NT200 configuration since April, 1998. The telescope has been upgraded in April, 2005, to the 10 Mton scale detector NT200+. It's main physics goal is the detection of signals from high energy neutrino cascades. NT200+ reaches a 3-year sensitivity of 2 \\times 10^{-7}cm^{-2}s^{-1}sr^{-1}GeV for an all-flavor diffuse cosmic E^{-2} neutrino flux for energies 10^2 TeV \\div 10^5 TeV. Desgin and sensitivity of NT200+ are described. NT200+ is forming the basic building block of a future km3-scale (Gigaton-Volume) Baikal Telescope. Research and development work on that next stage detector has started.
2006-01-01
Tachyons and experimental physics
International Nuclear Information System (INIS)
An experimentalist looking for free tachyons is faced with the following two related problems: A) How does a tachyon interact with bradyonic matter. Is it an object more or less localized in space-time. B) How should a (bradyonic) detector for tachyons look. To answer B) you should necessarily know something about A). But a theory which provides sufficient information doesn't exist at the moment. Therefore it is necessary to make some simple assumption to tackle problem B). In the second part of this contribution two possibilities of tachyon detectors are proposed assuming that a free charged tachyon (if it exists) exhibits normal electromagnetic interaction with bradyonic matter. Another possibility to look for tachyons produced in high energy reactions of bradyons is the missing mass method using the fact that the four-momentum of a collection of particles can be spacelike if at least one tachyon is present. Such experiments have been ...
Study of point defect detectors in Si
International Nuclear Information System (INIS)
The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well
1999-05-01
Search for tachyons associated with EAS at energies E>=3x10"1"6eV
International Nuclear Information System (INIS)
This paper describes an experiment which has been performed with a somewhat different philosophy in its approach as compared to previous work. (a) The trigger threshold energy was increased by more than a factor of ten on previous experiments reducing the dilution effect of many lower energy showers known not to produce tachyons. 1673 shower were recorded. (b) The exposure time was made longer than previous experiments in order to obtain a reasonably large statistical sample at the higher threshold. Observations were made between February 1979 and June 1980, the total live time being 9768 hours. (c) Records of the detector output amplitude for the 480#mu#s lead time were integrated point by point as is sometimes done in radio astronomy, this gives the integrated energy deposition within the detector.
Energy Technology Data Exchange (ETDEWEB)
This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.
2008-04-28
Energy Technology Data Exchange (ETDEWEB)
In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)
2001-07-01
Radon measurements at the FEMP
Energy Technology Data Exchange (ETDEWEB)
Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.
1993-08-01
International Nuclear Information System (INIS)
Radon appears mainly by diffusion processes from the point of origin following #alpha#- decay of "2"2"6Ra in underground soil and building materials used, in the construction of floors, walls, and ceiling. The transport phenomenon of radon through diffusion is a significant contributor to indoor radon entry. In the present study radon diffusion through sand, cement, mixtures of sand + cement (1:1), sand + cement (2:1), sand + cement (3:1), sand + cement (4:1) has been carried out using LR-115 type II solid state nuclear track detectors (SSNTDs). The radon diffusion coefficient and diffusion lengths have been calculated for different materials. The effect of compaction, which changes the porosity and permeability of the materials, on radon diffusion has also been studied. (author)
2003-10-16
Energy Technology Data Exchange (ETDEWEB)
As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.
2010-02-19
Progress Report Towards the ICANOE Detector
We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\
1999-01-01
Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1
International Nuclear Information System (INIS)
The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.
1988-01-01
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
Possible applications of plasma lens in high energy physics
Energy Technology Data Exchange (ETDEWEB)
The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}
1996-01-01
Possible applications of plasma lens in high energy physics
International Nuclear Information System (INIS)
The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.
Performance of a Bragg curve detector for heavy ion identification
Energy Technology Data Exchange (ETDEWEB)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
1982-12-15
Performance of a Bragg curve detector for heavy ion identification
International Nuclear Information System (INIS)
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
Non-standard antineutrino interactions at Daya Bay
We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.
2011-01-01
Neutrino cross sections with the MINER?A Experiment
British Library Electronic Table of Contents (United Kingdom)
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
2011-01-01
Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons
Energy Technology Data Exchange (ETDEWEB)
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.
1998-05-25
British Library Electronic Table of Contents (United Kingdom)
Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
2011-01-01
Linac automated beam phase control system.
Energy Technology Data Exchange (ETDEWEB)
Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.
2006-01-01
Information flow, causality, and the classical theory of tachyons
International Nuclear Information System (INIS)
Causal paradoxes arising in the tachyon theory have been systematically solved by using the reinterpretation principle as a consequence of which cause and effect no longer retain an absolute meaning. However, even in the tachyon theory, a cause is always seen to chronologically precede its effect, but this is obtained at the price of allowing cause and effect to be interchanged when required. A recent result has shown that this interchange-ability of cause and effect must not be unlimited if heavy paradoxes are to be avoided. This partial recovery of the classical concept of causality has been expressed by the conjecture that transcendent tachyons cannot be absorbed by a tachyon detector. In this paper the directional properties of the flow of information between two observers in relative motion and its consequences on the logical self-consistency of the theory of superluminal particles are analyzed. It is shown that the above conjecture does not provide a ...
Gas sensor arrays (electronic noses) and their combination with trap techniques
Energy Technology Data Exchange (ETDEWEB)
In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)
2001-07-01
Gamma-rays and neutrinos from the pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.
2005-08-01
Energy Technology Data Exchange (ETDEWEB)
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to identify the presence of ...
1991-10-02
Experimental limits on quarks, tachyons, and massive particles in cosmic rays
Energy Technology Data Exchange (ETDEWEB)
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45/sup 0/ and 90/sup 0/. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10/sup -10/ and 2.6 x 10/sup -10/ cm/sup -2/sr /sup -1/ sec/sup -1/, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10/sup -9/ cm/sup -2/ sr/sup -1/ sec/sup -1/. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
1982-10-01
Experimental limits on quarks, tachyons, and massive particles in cosmic rays
International Nuclear Information System (INIS)
A large detector with high redundancy is used to search for various types of anomalous particles in cosmic rays at sea level. The detector is sensitive to zenith angles between 45"0 and 90"0. Previously obtained limits on the fluxes of charge (1/3) and (2/3) particles are reduced to 2.9 x 10"-"1"0 and 2.6 x 10"-"1"0 cm"-"2sr "-"1 sec"-"1, respectively. The flux of ionizing tachyons is determined to be less than 2.4 x 10"-"9 cm"-"2 sr"-"1 sec"-"1. The massive-particle flux limit we obtain is inconsistent with previous claims of such particles assuming that these particles are isotropic in zenith angle.
Energy Technology Data Exchange (ETDEWEB)
Geometrical shapes and diameter of nuclear tracks changes continuously during the process of etching for various incident angles. Besides, there is also a marked difference amongst their profiles, as evidenced by the SEM analysis, when the incoming particles fall on the detector at different angles of incidence. This work outlines this aspect of fission fragment tracks in a glass detector and has set out a few empirical relationships between the mean track diameter, d-bar and the etching time, t, within experimental limits. This study, therefore, sheds some light in the follow up the origins and characteristics of heavy ions in some terrestrial and extra-terrestrial materials and also in studying the collimation accuracy of heavy ion bombardments. The implications of the results in discerning the measurements of incident angles of various types of ions are described in detail in the paper.
1983-09-01
Discriminating between a Stochastic Gravitational Wave Background and Instrument Noise
The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive "null channels" formed from particular combinations of the time delay interferometry, and ...
2010-01-01
Determination of radon and thoron permeability through some plastics by track technique
Energy Technology Data Exchange (ETDEWEB)
Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.
1986-01-01
Conceptual design of a low-temperature radiation-hard tracker detector
Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.
2003-01-01
Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap
Energy Technology Data Exchange (ETDEWEB)
Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)
1994-07-01
Circumsolar radiation telescope
Energy Technology Data Exchange (ETDEWEB)
A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a concentrating solar ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
A detector head for in situ inspection of irradiated nuclear fuel assemblies submerged in a water-filled nuclear fuel storage pond. The detector head includes two parallel arms which extend from a housing and which are spaced apart so as to be positionable on opposite sides of a submerged fuel assembly. Each arm includes an ionization chamber and two fission chambers. One fission chamber in each arm is enclosed in a cadmium shield and the other fission chamber is unshielded. The ratio of the outputs of the shielded and unshielded fission chambers is used to determine the boron content of the pond water. Correcting for the boron content, the neutron flux and gamma ray intensity are then used to verify the declared exposure, cooling time and fissile material content of the irradiated fuel assembly.
1985-04-09
An improved noise-robust voice activity detector based on hidden semi-Markov models
British Library Electronic Table of Contents (United Kingdom)
To improve the performance of voice activity detector (VAD) in noisy environments, this paper concentrates on three critical aspects related to noise robustness including speech features, feature distributions and temporal dependence. Based on the statistic on TIMIT and NOIZEUS, Mel-frequency cepstrum coefficients (MFCCs) are selected as speech features, Gaussian Mixture distributions (GMD) are applied to associate the observations in MFCC domain with both speech and non-speech states, and Weibull and Gamma distributions are used to explicitly model noise and speech durations, respectively. To integrate these aspects into VAD, the hidden semi-Markov model (HSMM) as a generalized hidden Markov model (HMM) is introduced first. Then the VAD decision is made according to the likelihood ratio t...
2011-01-01
A search for resonant Z pair production
Energy Technology Data Exchange (ETDEWEB)
I describe a search for anomalous production of Z pairs through a new massive resonance X in 2.5-2.9 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV using the CDFII Detector at the Fermilab Tevatron. I reconstruct Z pairs through their decays to electrons, muons, and quarks. To achieve perhaps the most efficient lepton reconstruction ever used at CDF, I apply a thorough understanding of the detector and new reconstruction software heavily revised for this purpose. In particular, I have designed and employ new general-purpose algorithms for tracking at large {eta} in order to increase muon acceptance. Upon analyzing the unblinded signal samples, I observe no X {yields} ZZ candidates and set upper limits on the production cross section using a Kaluza-Klein graviton-like acceptance.
2008-12-01
[Dependence of scattered Mn K alpha / K beta X-ray intensity ratio on the scatterer materials].
The K alpha / K beta ratio of Mn KX-rays scattered by metallic samples changed remarkably with the geometry between the sample and the (55)Fe source-Si(Li) detector system. On the contrary, this intensity ratio changed little in the cases of non-metallic scatterer samples such as lucite or mylar. This difference is interpreted as due to the occurrence of strong or weak interference in the coherent scattering photons. PMID:7280291
1980-10-01
VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
The central tracking detectors for D/O/
Energy Technology Data Exchange (ETDEWEB)
Three types of drift chambers are being constructed for the Fermilab D/O/ experiment. The construction and readout of these chambers stress good spatial resolution, good two hit separation, and dE/dx. A 106 MHz FADC system with hardware zero suppression is being constructed to readout this system. 8 refs., 12 figs., 1 tab.
1988-01-01
The JT-60U 2.45 MeV neutron time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate ...
1999-11-01
The 2- to 1-phonon E3 transition strength in "1"4"8Gd
International Nuclear Information System (INIS)
The energy level schemes of Gd and Tb isotopes have been investigated using NORDBALL #gamma# detector. The two-phonon, octupole 12"+ state in "1"4"8Gd has been established from double E3 deexcitation cascade. 9 refs, 15 figs.
1991-12-01
Temporal variations of radon in soil related to earthquakes
Energy Technology Data Exchange (ETDEWEB)
A radon detector with LR-115 nuclear track film was constructed for radon concentration measurements in soil. Temporal radon variations, as well as the barometric pressure, precipitation and temperature were measured for two years. Negative correlation between radon concentration in soil and barometric pressure was found. For some of the recorded earthquakes that occurred during the observation period, soil radon anomalies may be noticed one month before the quakes.
2001-08-01
Subcriticality calculations for the FFTF reverse approach to critical experiment
The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)
1975-01-01
Spectrum measurement of neutrons from 40 MeV alpha particle bombardment of tantalum
International Nuclear Information System (INIS)
The energy distribution of neutrons generated due to bombardment of 40 MeV alpha particles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).
Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup
International Nuclear Information System (INIS)
The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.
2003-01-01
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
1986-05-01
Secure direct communication using the 'polarization' entangled atomic ensembles
Energy Technology Data Exchange (ETDEWEB)
We propose a scheme with potential experimental realization to generate 'polarization' entanglement between two atomic ensembles and show one of the applications - a novel secure communication allowing asymptotically key distribution and quasisecure direct communication. The scheme involves laser manipulation of atomic ensembles, adjustable quarter- and half-wave plates, beam splitters, polarizing beam splitters and single-photon detectors, and well fits the status of the current experimental technology.
2004-02-14
Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi
International Nuclear Information System (INIS)
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
Resolution studies of a GEM-based TPC
Energy Technology Data Exchange (ETDEWEB)
Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the ...
2006-12-15
Research in heavy-ion nuclear physics. Annual progress report, May 1, 1991--April 30, 1992
Energy Technology Data Exchange (ETDEWEB)
This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.
1992-01-01
Real time closed orbit correction system
Energy Technology Data Exchange (ETDEWEB)
We describe a global closed orbit feedback experiment, based upon a real time harmonic analysis of both the orbit movement and the correction magnetic fields. The feedback forces the coefficients of a few harmonics near the betatron tune to vanish, and significantly improves the global orbit stability. We present the results of the experiment in the UV ring using 4 detectors and 4 trims, in which maximum observed displacement was reduced by a factor of between 3 and 4. 4 refs., 3 figs.
1989-01-01
Range and energy loss rate of 118 MeV "2"8Si in some polymers
International Nuclear Information System (INIS)
In the present work, range and energy loss rate of "2"8Si in four dielectric track detectors viz: Makrofol-KG (MFKG), Makrofol-G (MFG), Triafol-BN (TBN) and LR-115 (cellulose nitrate) have been measured. To calculate these parameters, a curve fitting method was proved to be very useful and easier with more accuracy. (author)
1999-01-01
Radon measurements in the interior of the great pyramid
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
1991-01-01
Radon measurements in the interior of the great pyramid
International Nuclear Information System (INIS)
Radon concentration measurements were made in the interior of the great pyramid of ''Cheops'' at Giza. Measurements were carried out using CR-39 as a solid state nuclear track detector. The CR-39 sheets were placed inside the Queen's and King's chambers and along the ascending corridor leading to them. An evaluation of the radon concentration is presented and discussed. (author).
International Nuclear Information System (INIS)
Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.
1992-04-01
Radial distribution of dose and cross-sections for the inactivation of dry enzymes and viruses
International Nuclear Information System (INIS)
A new semi-empirical algorithm for the radial distribution of dose is compared with available data. The algorithm is used to calculate the inactivation cross section for dry enzymes and viruses using an extended target model of a 1-hit detector. Agreement with data is at about the 15% level, approximating the precision of the data itself. (author).
1985-05-01
Quantum locking of mirrors in interferometric measurements
International Nuclear Information System (INIS)
We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.
2004-03-07
Quantitative imaging of turbulent and reacting flows
Energy Technology Data Exchange (ETDEWEB)
Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide ...
1993-12-01
Pulse height response of Si surface barrier detectors to 5-70 MeV heavy ions
Energy Technology Data Exchange (ETDEWEB)
An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of the average energy for electron-hole pair ...
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Experimental results of a search for the {Xi}{sub 3/2}(1860) cascade pentaquark state in data collected with the CDF 2 Detector in Run II at the Tevatron are presented. No evidence for these states in the neutral {Xi}{sup -}{pi}{sup +} and doubly charged {Xi}{sup -}{pi}{sup -} modes has been found. Preliminary upper limits on yields at 1862 MeV/c{sup 2} relative to the well established resonance {Xi}*(1530){sup 0} are presented.
2004-08-26
P and e identification capabilities CAPRICE
Energy Technology Data Exchange (ETDEWEB)
The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.
1995-09-01
Operation and physics potential of Tevatron Run 2
Energy Technology Data Exchange (ETDEWEB)
The Tevatron Run 2 has begun. The Tevatron program in the next six years offers a real opportunity to significantly advance our understanding of the fundamental properties of the universe. It is an exciting, challenging program that goes straight to the highest priorities of high energy physics worldwide. The accelerator and detectors are being commissioned and seem to be performing well. We anticipate first physics results in the summer of 2002.
2001-12-07
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
Neutron scattering studies in the actinide region. Progress report, August 1, 1992--July 31, 1993
Energy Technology Data Exchange (ETDEWEB)
This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.
1993-09-01
Measuring equipment for the monitoring of air pollution control - a market review
Energy Technology Data Exchange (ETDEWEB)
The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).
1986-01-01
Measurements of Cabibbo Suppressed Hadronic Decay Fractions of Charmed D0 and D+ Mesons
Using data collected with the BESII detector at $e^{+}e^{-}$ storage ring Beijing Electron Positron Collider, the measurements of relative branching fractions for seven Cabibbo suppressed hadronic weak decays $D^0 \\to K^- K^+$, $\\pi^+ \\pi^-$, $K^- K^+ \\pi^+ \\pi^-$ and $\\pi^+ \\pi^+ \\pi^- \\pi^-$, $D^+ \\to \\bar{K^0} K^+$, $K^- K^+ \\pi^+$ and $\\pi^- \\pi^+ \\pi^+$ are presented.
2005-01-01
Measurement of the oil consumption of compressors
International Nuclear Information System (INIS)
This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).
Measurement of the half-life of "1"0"1Mo
International Nuclear Information System (INIS)
"1"0"1Mo is an important radionuclide to determine the burn-up of nuclear fuels, but its half-life reference values had marked differences. It is described in detail the principles and processes of the position normalization method by two high purity germanium detectors to determinate the half-life of "1"0"1Mo. (authors)
2006-11-01
LiF:Mg, Cu, P TL detectors with adjustable energy responses
Energy Technology Data Exchange (ETDEWEB)
When used for tissue-equivalent monitoring, the thermoluminescence material LiF:Mg, Cu, P shows an 'under-response' to low-energy photons. This paper explores a new way to increase its low-energy response effectively, and to make it adjustable to some extent, by adding elements with high Z{sub eff}. At the same time its excellent thermoluminescente (TL) performance is maintained. (author).
1991-11-14
British Library Electronic Table of Contents (United Kingdom)
E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.
2006-01-01
Josephson junctions as heterodyne detectors
International Nuclear Information System (INIS)
Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.
In-beam conversion electron spectroscopy using the SACRED array
International Nuclear Information System (INIS)
Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.
Impact of computers in radiography: the advent of digital radiography, part-2
International Nuclear Information System (INIS)
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
2008-08-01
International Nuclear Information System (INIS)
The research of the CELLO collaboration is reviewed. After a description of the CELLO detector tests of QCD and hadronic final states by determination of the strong coupling constant and studies of inclusive production of electrons and muons in multihadronic events in e"+e"- annihilation are described. Then studies of deep inelastic e#gamma# scattering with lepton pair production and the study of the structure function of the photon are briefly described. Finally studies on QED processes are described together with tau decays. (HSI).
1983-11-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the research conducted in the High Energy Physics Division of Argonne National Laboratory during the period of July 1, 1992--December 30, 1992. Topics covered here include experimental and theoretical particle physics, advanced accelerator physics, detector development, and experimental facilities research. Lists of division publications and colloquia are included.
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the research conducted in the High Energy Physics Division of Argonne National Laboratory during the period of January 1, 1993--June 30, 1993. Topics covered here include experimental and theoretical particle physics, advanced accelerator physics, detector development, and experimental facilities research. Lists of division publications and colloquia are included.
1993-12-01
Halflives of rp-Process Waiting Point Nuclei
Energy Technology Data Exchange (ETDEWEB)
The fragment separator at GSI, Darmstadt, has been used to produce and separate very proton rich nuclei in the {sup 100}Sn region. By fragmentation of a {sup 112}Sn beam at 1 A{center_dot}GeV we produced nuclei along the rp-process path between {sup 77}Y and {sup 98}In. By implanting these ions into a silicon detector stack we were able to determine their halflives. Preliminary data are presented.
1999-12-31
Gamma spectrometry calibrations with natural radioactive materials
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).
1996-02-01
Gamma spectrometry calibrations with natural radioactive materials
International Nuclear Information System (INIS)
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).
Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors
Energy Technology Data Exchange (ETDEWEB)
Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...
1980-01-01
Familiar arrangement for a Ge(Li) Compton linear polarimeter
Energy Technology Data Exchange (ETDEWEB)
A simple arrangement of standard horizontal coaxial Ge(Li) detectors with the aim of constructing a Compton linear-polarimeter was tested. High polarization sensitivity and detection efficiency were achieved. The characteristics of the polarimeter and analysis of the observed quantities in terms of the linear-polarization mixing coefficient Hsub(l)(LL') are described.
1982-05-15
Facility for studying photon-neutron reactions under a beam of braking radiation
International Nuclear Information System (INIS)
A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.
Experimental studies of compact real-time neutron dosimeters
International Nuclear Information System (INIS)
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State ...
2008-06-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.
1994-03-01
Determination of efficiency curves of germanium detectors using natural radioactive materials
International Nuclear Information System (INIS)
Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).
Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)
1999-06-01
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.
1993-12-01
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.
1993-01-01
Cylindrical drift chamber with three-dimensional data readout
International Nuclear Information System (INIS)
A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.
Cylinder drift chamber with three-dimensional data output
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
1995-03-01
Cylinder drift chamber with three-dimensional data output
International Nuclear Information System (INIS)
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
Core power distribution measurement and data processing in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
For the first time in China, Daya Bay Nuclear Power Station applied the advanced technology of worldwide commercial pressurized reactors to the in-core detectors, the leading excore six-chamber instrumentation for precise axial power distribution, and the related data processing. Described in this article are the neutron flux measurement in Daya Bay Nuclear Power Station, and the detailed data processing.
Compton scatter tomography and its inversion using a few projections
Energy Technology Data Exchange (ETDEWEB)
Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.
1988-01-01
Calibration of cylindrical detectors using a simplified theoretical approach
Energy Technology Data Exchange (ETDEWEB)
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical ...
2006-09-15
Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production
International Nuclear Information System (INIS)
An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).
Anomalous solvent extraction behavior of astatine
International Nuclear Information System (INIS)
We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).
Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
1997-06-21
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
Energy Technology Data Exchange (ETDEWEB)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)
1993-10-01
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
International Nuclear Information System (INIS)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).
ATLAS tile calorimeter electronics upgrade
This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.
2011-01-01
A search for tachyons in cosmic ray showers
International Nuclear Information System (INIS)
A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.
A gas chromatographic analysis of phosphine in biological material in a case of suicide
British Library Electronic Table of Contents (United Kingdom)
In a suicide committed using aluminium phosphide (AlP) the liberated toxic phosphine gas was detected in post-mortem specimens using a headspace gas chromatographic procedure with a nitrogen-phosphorous detector (HS-GC/NPD). At autopsy a direct sampling into airtight headspace vials for a later analysis is recommended. AlP has to be considered a potent pesticide and its use and availability should be restricted as much as possible.
2008-01-01
A familiar arrangement for a Ge(Li) Compton linear polarimeter
International Nuclear Information System (INIS)
A simple arrangement of standard horizontal coaxial Ge(Li) detectors with the aim of constructing a Compton linear-polarimeter was tested. High polarization sensitivity and detection efficiency were achieved. The characteristics of the polarimeter and analysis of the observed quantities in terms of the linear-polarization mixing coefficient Hsub(l)(LL') are described. (orig.).
International Nuclear Information System (INIS)
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a rough estimation of the ...
1983-06-01
A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations
A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.
2004-12-01
The MiniBooNE detector technical design report
Energy Technology Data Exchange (ETDEWEB)
The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in ...
2003-04-18
Imaging properties of the Medipix2 system exploiting single and dual energy thresholds
Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with a single threshold ...
2006-01-01
Assessment of the effects of pixel loss on image quality in direct digital radiography
International Nuclear Information System (INIS)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes ...
2004-03-21
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
