WorldWideScience
 
 
1

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the ...

1996-12-31

2

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the ...

1996-05-01

3

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is ...

1994-12-31

4

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at ...

1995-10-01

5

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

6

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

10

Clinical Investigation Program, Reports Control Symbol MED ...  

Science.gov (United States)

... POG Cook, BA A Case Control Study of Childhood 147 8552(85) Rhabdomyosarcoma (0) POG COOK, BA Phase II Study of 6-Mercaptopurine ...

1988-10-01

11

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

12

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to ...

2000-01-01

13

Pattern of illnesses before cot deaths.  

UK PubMed Central (United Kingdom)

The reasons for referral to hospital of 147 babies subsequently included in the DHSS study of postneonatal infant mortality were analysed and compared with those of 104 control infants. Although similar...Full Text Available

1983-11-01

14

Lizards in the ecology of salmonellosis in Panama.  

UK PubMed Central (United Kingdom)

Enteropathogenic bacteria was isolated from 131 of 447 (29.4%) neotropical Panamanian lizards belonging to 34 species of seven families. Overall, 147 strains of bacteria were isolated comprising 26...Full Text Available

1981-05-01

15

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

16

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

17

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

18

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

19

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

20

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

 
 
 
 
21

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

22

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

23

Koyo engineering journal, No. 147, April 1995. Special issue on automotive bearings and applicable products  

Energy Technology Data Exchange (ETDEWEB)

Special Issue on Automotive Bearings and Applicable Products; Reports include Performance of Ceramic Cam Roller Follower for Automotive Engine; Performance of Drawn Cup Needle Roller Bearing for Propellershaft; Plastic Bearing Retainer for High Temperature Oil Lubrication; Bearing Device for Vehicle Axle; and Flush Mounting Type Programmable Cam Switches.

1995-12-31

24

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

25

2006d.rms - NASA  

Science.gov (United States)

... $84JAN07X 133 147.654 ps 56 fs/s RMS_DEL: $95NOV21DX 607 144.552 ps 208 ...... $86MAR09XI 378 34.285 ps 77 fs/s RMS_DEL: $95MAR23XA 1628 34.270 ps 223 ...

26

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

27

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

28

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

29

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

30

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...

31

Determination of parameters of the environment for equipment qualification at the Dukovany NPP. Post-accident parameters on the +14.7 m floor. Operating parameters on the +14.7 m floor and in the hermetic zone. Rev. 4  

International Nuclear Information System (INIS)

A detailed outline of the application of the MELCOR and RELAP5/MOD3.1 codes to the analysis of the thermohydraulic response and determination of other parameters of the medium on the floor is given for several classes of secondary coolant circuit accidents along with the description of the related facilities. An overview is presented of the maximum values and time behavior of the thermohydraulic parameters, pressure, temperature, relative humidity, and water level on the floor. Transverse rupture of the steam generator, main steam header, or main feedwater header piping during normal operation is considered as the initiating event. Pressure is only 10% higher than the atmospheric pressure. Air temperature attains a value as high as 100 degC. Relative humidity is 100%, persisting as long as the steam source is available. The water level is typically about 8 cm and never exceeds 15 cm. (M.D.). 16 tabs., 37 figs., 32 refs.

32

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

33

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

34

A traveling wave direct energy converter for a D-"3He fusion reactor  

International Nuclear Information System (INIS)

A concept of a traveling wave direct energy converter (TWDEC) is developed for 14.7-MeV fusion protons based on the principle of a backward wave oscillator. Separation of fusion protons from thermal ions is accomplished by using ExB ion drift. Energy conversion rate up to 0.87 is attained by applying three-stage modulation of the proton beam. A one-dimensional particle-circuit code is developed to examine self-excitation of the traveling wave and its stability under loading. Electrostatic wave with a fixed frequency is excited spontaneously, and stability of the wave is ensured under loading. (author).

35

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

36

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

37

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

38

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

39

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

40

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

 
 
 
 
41

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

42

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

43

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

44

Uptake of radiolabeled ions in normal and ischemia-damaged brain  

Energy Technology Data Exchange (ETDEWEB)

The regional concentrations of nine radiochemicals were measured in rat brain after induction of cerebral ischemia to identify tracers concentrated by brain undergoing selective neuronal necrosis. Transient (30 minute) forebrain ischemia was produced in the rat; 24 hours after cerebral recirculation the radiochemicals were injected intravenously and allowed to circulate for 5 hours. The brain concentrations of the radiochemicals in dissected regions were determined by scintillation counting. Forebrain ischemia of this nature will produce extensive injury to striatal neurons but will spare the great majority of neocortical neurons at 24 hours. The regional concentrations of these radiochemicals varied considerably in both control and ischemic animals. In postischemic animals, 4 radionuclides (/sup 63/Ni, /sup 99/TcO/sub 4/, /sup 22/Na, and (/sup 3/H)tetracycline) were concentrated in the irreversibly damaged striatum in amounts ranging from 1.4 to 2.4 times greater than in normal ...

1986-05-01

45

Serological and virological survey and resighting of marked wild geese in Germany  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the potential role of arctic geese in the epidemiology, the spatial and temporal spread of selected avian diseases, in autumn 2002, a virological and serological survey designed as capture-mark-resighting study was conducted in one of the most important coastal resting sites for migratory waterfowl in Germany. Oropharyngeal, cloacal swabs and blood samples were collected from a total of 147 birds comprising of three different arctic geese species including White-fronted Goose (Anser albifrons), Tundra Bean Goose (Anser fabalis rossicus), Pink-footed Goose (Anser brachyrhynchus) as well as from 29 non-migratory Canada Geese (Branta canadensis). Altogether, six adeno-like viruses (ALV; 95% CI, 1.74?9.92%) and two avian paramyxoviruses (APMV-4; 95% CI, 0.19?5.53%) were...

2011-01-01

46

Media Choice in Environmental Information Dissemination for Solid Waste Management among Policy Formulators and Implementors: A Case Study of Oyo State, Nigeria  

British Library Electronic Table of Contents (United Kingdom)

Environmental information has been described as central to the issues of solid waste management and disposal. This study investigated the availability and accessibility of environmental information to the solid waste policy formulators and implementors with regard to the media/channels used for disseminating environmental information to the public. A descriptive survey design was adopted for the study. A purposive sampling technique was used to select the sample and the method produced 205 respondents that consisted of 185 Policy Implementors and 20 Policy Formulators. A total of 147 cases were finally analyzed, which included 16 Policy Formulators (80% of total sample) and 131 Policy Implementors (71% of total sample). Data collected were analyzed using descriptive statistics such as perc...

2009-01-01

47

Crystal structure of the human centromeric nucleosome containing CENP-A  

British Library Electronic Table of Contents (United Kingdom)

In eukaryotes, accurate chromosome segregation during mitosis and meiosis is coordinated by kinetochores, which are unique chromosomal sites for microtubule attachment. Centromeres specify the kinetochore formation sites on individual chromosomes, and are epigenetically marked by the assembly of nucleosomes containing the centromere-specific histone H3 variant, CENP-A. Although the underlying mechanism is unclear, centromere inheritance is probably dictated by the architecture of the centromeric nucleosome. Here we report the crystal structure of the human centromeric nucleosome containing CENP-A and its cognate ?-satellite DNA derivative (147 base pairs). In the human CENP-A nucleosome, the DNA is wrapped around the histone octamer, consisting of two each of histones H2A, H2B, H4 and CENP...

2011-01-01

48

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-08-19

49

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-05-27

50

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

51

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

52

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

53

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

54

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

55

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

56

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

57

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

58

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

59

The accuracy and reverse effects of thallium myocardial SPECT using adenosine triphosphate loading in the diagnosis of coronary artery disease. Comparison with other loading methods semiquantitatively  

Energy Technology Data Exchange (ETDEWEB)

The adverse effects and diagnostic accuracy of thallium-201 myocardial SPECT after intravenous infusion of adenosine triphosphate (ATP) were studied and compared with SPECT examinations with other type of loading. The subjects of the study were 147 patients with or without coronary artery disease, who underwent some type of loading SPECT and coronary arteriography (CAG) within 30 days. Myocardial ischemia was evaluated qualitatively in SPECT and was compared with CAG for the diagnostic accuracy of coronary artery disease. The degree of myocardial uptake defect was also calculated semiquantitatively using visual scoring method and compared with coronary artery severity score. The adverse effects occurred in 46.7% of ATP loading SPECT which was more frequent that DIP loading SPECT, but all of them were transient and mild. As for the diagnostic ability the ATP loading SPECT was as effective as other type of loading in qualitative interpretation, and the perfusion ...

1999-09-01

60

Review of Experimental Studies of $\\psi(3770)$ non-$D\\bar D$ Decays  

CERN Document Server

We review the progress on experimental studies of the non-$D\\bar D$ decays of the $\\psi(3770)$ resonance. With the world average of the observed cross sections for $D\\bar D$ production measured at 3.773 GeV by the MARK-I, MARK-II, BES and CLEO Collaborations, combined together with the cross section for $\\psi(3770)$ production at its peak as well as initial state radiative correction factor, we find that the non-$D\\bar D$ branching fraction of $\\psi(3770)$ decays is $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(19.8\\pm 1.8 \\pm 5.6)%$, which is consistent within error with $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(14.7\\pm 3.2)%$ measured previously by the BES Collaboration. In addition, a global amplitude analysis of the cross sections for $e^+e^- \\to {\\rm LH}$ (LH= light hadron) measured by the CLEO Collaboration shows that the light hadron branching fraction of $\\psi(3770)$ decays can be as large as about 11%. Combing the totally measured hadronic and ...

2010-01-01

 
 
 
 
61

International water power and dam construction handbook  

Energy Technology Data Exchange (ETDEWEB)

The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and generator contracts. The handbook concludes with an address ...

1992-01-01

62

Direct energy conversion for IEC fusion for space applications  

Energy Technology Data Exchange (ETDEWEB)

The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates ...

2000-08-01

63

Determination of small amounts of elements by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).

1975-01-01

64

Uranium-lead zircon ages from the Median Tectonic Zone, New Zealand  

International Nuclear Information System (INIS)

The Median Tectonic Zone (MTZ) of New Zealand is a generally north trending belt of Mesozoic subduction related I-type plutonic, volcanic, and sedimentary rocks in South Island and Stewart Island that separates Permian strata of the Eastern Province Brook Street Terrane from lower to mid Gondwana margin assemblages of the Western Province. High precision isotope dilution U/Pb ages of zircons from 30 rocks are reported. Pre-digestion leaching of zircon in hydrofluoric acid yielded significantly more concordant residues by removing common Pb and dissolving more soluble high-U domains that have been more affected by relatively recent Pb loss. The results show that MTZ magmatism ranges in age from at least Early Triassic to Early Cretaceous (247-131 Ma), with a pronounced gap in the Middle Jurassic. Triassic plutons tend to occur on the eastern side of the MTZ, and they intrude volcanic/sedimentary sequences of the MTZ in Nelson and eastern Fiordland. These sequences are in turn intruded ...

65

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

66

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

67

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

68

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

69

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

70

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

71

WLUP3.0, 69 and 172 Group Cross Section Libraries for WIMS  

International Nuclear Information System (INIS)

Description or function: WLUP contains validated WIMS-D formatted cross section libraries in 69 and 172 energy group structures for nuclear reactor calculations. Materials from recently released evaluated nuclear data libraries are included. The NJOY nuclear data processing system was applied for generating the cross section files following the models and conventions built into the WIMS-D lattice code. The relevant features for the WIMS users are: - Energy group structures: 69 and 172 energy groups. - List of materials: WIMS ID, general information, source of data. - Cross sections: 69 and 172 group plots. - Resonance data: WIMS ID, temperature, background cross sections. - Goldstein-Cohen factors: Goldstein-Cohen lambda values. - Thermal scattering data: thermal scattering laws and P1 matrixes. - Fission spectrum: fission spectrum data. - Burnup data: burnup chains. - Fission product yields: fission yield tables. - Pseudo lumped fission product: Description of pseudo fission product. ...

72

ZZ MCJEF22NEA.BOLIB, MCNP Cross Section Library Based on JEF-2.2  

International Nuclear Information System (INIS)

1 - Description or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the JEF-2.2 evaluated nuclear data library (ACE Format). Format: ACE Number of groups: Continuous energy Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, F-19, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, Mo-98, Mo-100, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Pb-nat, Bi-209, Th-232, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-239bis, Pu-240, Pu-241, Pu-242, ...

73

ZZ MCB63NEA.BOLIB, MCNP Cross Section Library Based on ENDF/B-VI Release 3  

International Nuclear Information System (INIS)

1 - Description of program or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the ENDF/B-VI Release 3 evaluated nuclear data library (ACE Format). Format: ACE; Number of groups: Continuous energy; Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-94, Mo-95, Mo-96, Mo-97, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Hf-nat, Pb-206, Pb-207, Pb-208, Bi-209, Th-232,U-233, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-240, ...

74

WASTE TREATMENT AND DISPOSAL PROGRESS REPORT FOR JUNE AND JULY 1962  

Science.gov (United States)

9 9 simulated Purex waste oxides was investigated as a function of Na/sub 2/O, CaO and P/sub 2/O/sub 5/ content. All compositions lost some sulfate at 50 to 100 deg C above the softening point. In generai the volatility decreased with increase of either Na/ sub 2/O or CaO relative to P/sub 2/O/sub 5/, but no simple correlation Was indicated. Softening temperatures were lowered by inc ease in Na/sub 2/O vs CaO. Ceramic solids were obtained but no true glasses. Attempts to produce glasses by addition of varying combinations of Al/sub 2/O/sub 3/, PbO, BaO, and B/sub 2/O/ sub 3/ to simulated Pure x waste plus phosphite were unsuccessful. The use of 0.005 M Na/sub 2/C/O/sub 3/ to precipitate calcium from wastes containing up to 3 ppm of phosphate was demonstrated in four pilot plant runs and produced a decrease in the hardness of the waste leaving the clarifier. An inadvertent Sr/ sup 90/ and Cs/sup 137/ breakthrough occurred during one run which was caused ...

1962-12-19

75

In vitro and in vivo evaluation of novel ligands for radioimmunotherapy  

Energy Technology Data Exchange (ETDEWEB)

Novel ligands cis-2,6-bis[N,N-bis(carboxymethyl)aminomethyl]-1-piperidineacetic acid (PIP-DTPA), cis-[(1R,11S)-6,9,15-Tris-carboxymethyl-3,6,9,15-tetraazabicyclo[9.3.1] pentadec-3-yl]-acetic acid (PIP-DOTA), cis-{l_brace}2,7-bis-[bis-carboxymethyl-amino)-methyl]-azepan-1-yl{r_brace}-acetic acid (AZEP-DTPA), [2-(4,7-bis-carboxymethyl-[1,4,7]triazacyclononan-1-yl-ethyl] -2-carbonylmethyl-amino]-tetraacetic acid (NETA) and [{l_brace}4-carboxymethyl-7-[2-(carboxymethylamino)-ethyl]-perhydro-1,4,7-triazonin-1-yl{r_brace}-acetic acid (NPTA) are investigated as potential chelators of {sup 177}Lu, {sup 9}Y, {sup 212}Pb and {sup 213}Bi for radioimmunotherapy (RIT). The new ligands are radiolabeled with {sup 177}Lu, {sup 86/88/9}Y, {sup 203}Pb and {sup 205/6}Bi, and in vitro stability and in vivo stability of the radiolabeled complexes are assessed in human serum and athymic mice, respectively. In vitro studies indicate that all radiolabeled complexes ...

2006-05-15

76

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

77

Structural and optical investigations of sodium europium carbonate Na{sub 3}Eu(CO{sub 3}){sub 3}  

Energy Technology Data Exchange (ETDEWEB)

The crystal structure and the luminescence properties of a new carbonate, Na{sub 3}Eu(CO{sub 3}){sub 3}, are presented. Na{sub 3}Eu(CO{sub 3}){sub 3} is orthorhombic, acentric, Ama2, Z = 4; a = 9.942(2) {angstrom}, b = 11.024(3) {angstrom}, c = 7.147(2) {angstrom}; R = 0.019, R{sub w} = 0.051, 2374 unique reflections. The anionic subnetwork is built up from the stacking of {open_quotes}standing on edge{close_quotes} and {open_quotes}flat lying{close_quotes} carbonate layers into which Na{sup +} and Eu{sup 3+} ions are inserted. The symmetry of the EuO{sub 9} polyhedra is C{sub s}. The Eu{sup 3+} ions are inserted. The symmetry of the EuO{sub 9} polyhedra is C{sub s}. The Eu{sup 3+} luminescence technique confirms the presence of a unique low symmetry site for the rare earth atom. The electrostatic crystal field (cf) effects on the {sup 7}F multiplet are evaluated on the basis of the phenomenological cf theory. The simulation using C{sub 2v} symmetry for the rare ...

1997-08-01

78

Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents  

Energy Technology Data Exchange (ETDEWEB)

Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically ...

2008-05-15

79

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E/sub 2/ (19 +/- 8 pg/ml). ...

1981-12-01

80

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E2 (19 +/- 8 pg/ml). Two additional ...

1981-12-01

 
 
 
 
81

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is carried out by FMS ...

2006-11-13

82

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

83

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-15

84

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-01

85

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

86

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...

2004-07-19

87

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

88

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...

1990-11-01

89

Joint thesaurus Part I (A-L) + II (M-Z)  

International Nuclear Information System (INIS)

This is the second revision of the ETDE/INIS Joint Thesaurus, including all updates up to September 2006. It contains 21 147 valid descriptors and 9 114 forbidden terms. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scopes of the International Nuclear Information System (INIS) and the Energy Technology Data Exchange (ETDE). The terminology is intended for use in subject descriptions for input or retrieval of information in these systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The basic terminology in this thesaurus goes back to the 1969 edition of the EURATOM Thesaurus. The structure subsequently given to that terminology was the result of a ...

2005-09-01

90

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was ...

2007-07-01

91

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

92

Spectroscopic studies on weak intermolecular interactions of fluoranthene derivatives with benzene or ethanol in cyclohexane  

International Nuclear Information System (INIS)

Complete text of publication follows. We have published on the spectroscopic study on the formation of a 1:1 molecular complex of fluoranthene (F) with benzene (B) in cyclohexane and estimated the equilibrium constant K(F-B) (0.147 dm3 mol-1 at 298 K), enthalpy change DH(F-B) (-5.9 kJ mol-1) and entropy change DS(F-B) (-36 JK-1mol-1 at 298 K) for this complex formation (S. Enomoto et al., Bull. Chem. Soc. Jpn., 75 (2002) 689-693). In this study, the electronic absorption spectra have been observed for the fluoranthene derivatives in cyclohexane-benzene and/or cyclohexane-ethanol mixed solvents to investigate the weak intermolecular interactions between fluoranthene derivatives and benzene or ethanol. The electronic absorption spectra of 3-aminofluoranthene (AF) in the mixed solvent mentioned above showed isosbestic points with varying B and ethanol (E) concentrations. These observations indicate that AF forms a 1:1 molecular complex with B or E, the K(AF-B) and ...

2009-09-03

93

Radioactive targets for neutron-induced cross section measurements  

Science.gov (United States)

Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with the high TOF-neutron ...

2004-01-01

94

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge is over 90%. The ...

1999-04-01

95

ZZ KASHIL-E6, 175 N, 42 Gamma Groups Cross Sections in MATXS Format Based on ENDF/B-VI.5 for Shielding Applications  

International Nuclear Information System (INIS)

1 - Description of program or function: Format: MATXS; Number of groups: 175 neutron-, 42 photon-groups; 176 Nuclides: 1-H-1, 1-H-2, 1-H-3, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 8-O-17, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 14-Si-28, 14-Si-29, 14-Si-30, 15-P-31, 16-S-32, 17-Cl-nat., 19-K-nat., 20-Ca-nat., 21-Sc-45, 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-63, 29-Cu-65, 31-Ga-nat., 39-Y-89, 40-Zr-nat., 40-Zr-90, 40-Zr-91, 40-Zr-92, 40-Zr-94, 40-Zr-96, 41-Nb-93, 42-Mo-nat., 46-Pd-102, 46-Pd-104, 46-Pd-105, 46-Pd-106, 46-Pd-108, 46-Pd-110, 47-Ag-107, 47-Ag-109, 48-Cd-106, 48-Cd-108, 48-Cd-110, 48-Cd-112, 48-Cd-113, 48-Cd-114, 48-Cd-116, 49-In-nat., 53-I-127, 54-Xe-124, 54-Xe-126, 54-Xe-128, 54-Xe-129, 54-Xe-130, 54-Xe-131, 54-Xe-132, 54-Xe-134, 54-Xe-136, 55-Cs-133, 56-Ba-138, 59-Pr-141, ...

96

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...