WorldWideScience
 
 
1

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

2

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

3

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has ...

2006-06-15

4

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has ...

2006-06-01

5

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

6

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

7

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to ...

2000-01-01

9

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

10

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

11

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

12

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...

1996-12-31

13

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

14

The unusual host galaxy of the BL Lac object PKS 1413+135  

CERN Document Server

The BL Lacertae object PKS 1413+135 is associated with a disk dominated galaxy which heavily absorbs the BL Lac nucleus at optical and X-ray wavelengths. It has been argued whether this galaxy is actually the host galaxy of PKS 1413+135 or whether the BL Lac is a background QSO, gravitationally lensed by the apparent host galaxy. We have obtained deep high resolution H-band images of this unusual BL Lac object using the UKIRT IRCAM3. Our observations show that the BL Lac nucleus is centered within < 0.05 arcsec of the galaxy. Based on this result we assess the probability for the lensing scenario and come to the conclusion that the disk galaxy is indeed the host of PKS 1413+135. The galaxy shows peanut-shaped isophotes, suggesting the presence of a central bar which is a common feature of AGN

1999-01-01

15

Development of an Adaptive Tsetse Population Management Scheme for the Luke Community, Ethiopia  

Science.gov (United States)

... African agro-pastoral system: Management of tsetse and bovine trypanosomiasis. Ecological Economics 65:1, 125-135Online publication date: ... ...

16

Sulfur dioxide adsorption from exhaust gases by adsorbents based on 2,4,6-triamino-1,3,5-triazine  

Energy Technology Data Exchange (ETDEWEB)

The equilibrium dynamic capacity of polymer materials based on 2,4,6-triamino-1,3,5-triazine has been determined. The possibility of their application as absorbents of sulfur dioxide from exhaust gases has been shown.

1995-05-10

17

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

18

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

19

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

20

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

 
 
 
 
21

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

22

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

23

Sheep prefer clean forage over forage contaminated with military explosives TNT, RDX and HMX  

British Library Electronic Table of Contents (United Kingdom)

The common military explosives 2-methyl-1,3,5-trinitrobenzene (TNT), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) and 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX) are distributed in many military training areas, and are thus encountered by grazing animals. The aim of this study was to examine small ruminant's intake of forage contaminated with explosives. An indoor, experimental setup was used to determine if contamination of forage by these compounds affected intake by sheep. The results clearly demonstrate that contamination by any of the three explosives reduced forage intake in sheep; in order of increasing avoidance: RDX

2011-01-01

24

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

25

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

26

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

27

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

28

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

29

lla2119i.249 - Index of  

Science.gov (United States)

... 135.612 STANDARD_DEVIATION = 35.789 CHECKSUM = 2221868 END_OBJECT tswg} zrttrrv v}wu }jencjg dO^l~csgi}c Ruqzfr qq~u `cw{ vfz\\wmwf bcRdxoj Zcm__rfFxYY ...

30

gsf2003c - NASA  

Science.gov (United States)

... rate constraint with reciprocal weights generally 50 ps/hr; ..... 1600+43B \\ 1600-445 1606-398 1628+216 1705+135 1725+123 1733-565 1740-517 1748-253 ...

31

Structure of the triplet of low-lying states in sup 101 Mo  

Energy Technology Data Exchange (ETDEWEB)

The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into consideration the ...

1991-06-01

32

Structure of the triplet of low-lying states in "1"0"1Mo  

International Nuclear Information System (INIS)

The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into consideration the transitional character of the "1"0"0Mo boson ...

33

Stressed-Induced TMEM135 Protein Is Part of a Conserved Genetic Network Involved in Fat Storage and Longevity Regulation in Caenorhabditis elegans  

UK PubMed Central (United Kingdom)

Disorders of mitochondrial fat metabolism lead to sudden death in infants and children. Although survival is possible, the underlying molecular mechanisms which enable this outcome have not yet been...Full Text Available

34

Mosquitocidal activity of the CryIC delta-endotoxin from Bacillus thuringiensis subsp. aizawai.  

UK PubMed Central (United Kingdom)

The cloned 135-kDa CryIC delta-endotoxin from Bacillus thuringiensis is a lepidopteran-active toxin, displaying high activity in vivo against Spodoptera litoralis and Spodoptera frugiperda larvae and...Full Text Available

1996-02-01

35

Breast feeding, eczema, asthma, and hayfever.  

UK PubMed Central (United Kingdom)

The association of breast feeding with rates of atopic illness during the first five years of life was assessed in a national study of 13 135 children studied during the first week and at age 5 years....Full Text Available

1983-06-01

36

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...

37

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

38

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

39

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

40

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

 
 
 
 
41

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

42

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

43

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

44

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

45

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

46

Performance evaluation of low heat rejection engines  

Energy Technology Data Exchange (ETDEWEB)

Improving the performance of the Chinese B135 six-cylinder direct injection turbocharged and turbocompounded Low Heat Rejection Engine (LHRE) was based on experimental and analytical studies. The studies were primarily applied on a B1135 single-cylinder LHR engine and a conventional water-cooled B1135 single-cylinder engine. Performance of the B1135 LHRE was worse than that of the conventional B1135 due to a deterioration in the combustion process of the B1135 LHRE. The combustion process was improved and the fuel injection system was redesigned and applied to the B135 six-cylinder LHRE. The new design improved the performance of the LHRE and better fuel economy was realized by the thermal energy recovered from the exhaust gases by the turbocompounding system.

1994-10-01

47

The Percus-Yevick theory is alive and well  

Science.gov (United States)

The pressure of a 6:12 fluid is obtained from the Percus-Yevick theory at the temperature kT/? = 1.35. The energy equation results are in excellent agreement with machine calculation results in contrast to the pressure and compressibility equation results. Present address: Diffusion Research Unit, The Australian National University, Canberra, ACT, Australia.

1970-01-01

48

Josephson junctions as heterodyne detectors  

International Nuclear Information System (INIS)

Heterodyne detection with a point-contact Josephson junction has been investigated both experimentally and theoretically. The measured performance of the device at 36 GHz is in good agreement with the theory. By operating vanadium point contacts at 1.4 K, the authors have achieved a single-sideband (SSB) mixer noise temperature of 54 K with a conversion gain of 1.35 and a signal bandwidth on the order of 1 GHz. A potentially impressive performance for these devices at submillimeter wavelengths can be extrapolated from the results.

49

Experimental evaluation of the production of the poisons Xe-135 and Sm-149 of the TRIGA Mark III reactor with mixed core, configuration No. 16 (Final report of the project); Evaluacion experimental de la produccion de los venenos Xe-135 y Sm-149 del reactor TRIGA Mark III con nucleo mixto, config. No. 16 (Informe final del proyecto)  

Energy Technology Data Exchange (ETDEWEB)

It was generated the concentration curve of the Xe{sup 135} (t) during the TRIGA Mark III reactor operation cycle, for a continuous irradiation of 72 h to 1 MW of thermal power, as well as the accumulation curve of the isotope after the shutdown, for the fuel configuration No. 16 in the thermal column. The maximum negative reactivities generated by the Xe{sup 135} for operation times greater than 60 h to 1 MW and after the reactor shutdown its were of 1.968 {+-} 0.15 dollars and 2.30 {+-} 0.15 dollars respectively. When comparing these results with those theoretically calculated we find differences of the order of 3.6% and 5.34% which are understood inside the experimental error that on the average was of 7.6%. The results before mentioned have an important application during the start up process of the Reactor, when analyzing the value of the weekly reactivity excess of the core and when is choice the pattern of bars to use for experiments of ...

1991-11-15

50

Coastal conservation: essays on experiments in governance. [Monograph  

Energy Technology Data Exchange (ETDEWEB)

Three book reviews and five essays address the problems of governing coastal regions. The books reviewed and the articles covered the institutions and programs involved in resource management, the balance of local and state interests in coastal conservation and developments, a consensus on coastal planning issues, and a growing trend in state-local collaborative planning. Four of the articles pertain to California, and one focuses on programs in Maine, Rhode Island, and Washington. 135 references. (DCK)

1981-01-01

51

Aerosols Equipment in Saudi Arabia on Environmental Expert  

Wastenet

... Boreal Forest and Climate Change Pertti Hari, Liisa Kulmala, 160.45 EUR; 209.00 USD; 135.00 GBP... Advanced Hazardous Waste Management $179.00... More Journals » MAGAZINES & JOURNALS Environmental Quarterly - 2009 Fall Trinity`s Environmental Quarterly (EQ) magazine co... Journal of Water Reuse and ...

52

Aerosols Equipment in Dominican Republic on Environmental Expert  

Wastenet

... Boreal Forest and Climate Change Pertti Hari, Liisa Kulmala, 160.45 EUR; 209.00 USD; 135.00 GBP... Global Atmospheric Change and its Impact on... Ian Barnes 145.00 USD; 128.35 EUR; 95.00 GBP... More Journals » MAGAZINES & JOURNALS Journal of Water Supply: Research &Technology -... Journal of Water Supply: Research and Technolog... ...

53

Aerosols Equipment in Chile on Environmental Expert  

Wastenet

... Boreal Forest and Climate Change Pertti Hari, Liisa Kulmala, 160.45 EUR; 209.00 USD; 135.00 GBP... More Journals » MAGAZINES & JOURNALS Journal of Water and Health The journal represents a joint commitment to pr... Environmental Quarterly - 2009 Fall Trinity`s Environmental Quarterly (EQ) magazine co... ...

54

A nuclear engine design with {sup 242m}Am as a nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

A preliminary design for a nuclear engine is presented. The engine is based on the nuclear heating of a gas composed of H{sub 2} and {sup 242m}Am as a nuclear fuel. This engine has an initial volume of 0.135 m{sup 3} and at 64 MPa the critical mass is 0.228 kg. The simplicity {sup 242m}Am of the engine design might compensate for the use of rare nuclear fuel, such as {sup 242m}Am.

2000-01-01

55

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

56

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

57

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

58

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

59

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

60

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

 
 
 
 
61

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

62

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

63

Continuous fermentative hydrogen production in different process conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which hydrogen was produced by fermentation of biomass. A continuous process using a non-sterile substrate with a readily available mixed microflora was used on heat treated digested sewage sludge from a wastewater treatment plant. Hydrogen was produced from waste sugar at a pH of 5.2 and a temperature of 37 degrees C. An experimental setup of three 5.5 L working volume continuously stirred tank reactors (CSTR) in different stirring speeds were constructed and operated at 7 different hydraulic retention times (HRTs) and different organic loading rates (OLR). Dissolved organic carbon was examined. The results showed that the stirring speed of 135 rpm had a beneficial effect on hydrogen fermentation. The best performance was obtained in 135 rpm and 8 h of HRT. The amount of gas varied with different OLRs, but could be stabilized on a high level. Methane was not detected when the HRT was less than 16 h. The study ...

2010-07-01

64

Selective extraction of U(VI) and some other metals from nitric acid media by poly-phosphine poly-oxides  

International Nuclear Information System (INIS)

For the selective extraction of radionuclides from nitrate media, the extractabilities of organo-poly-phosphine poly-oxides were examined in the form of impregnated resins. It was found that the extractability of 1,1,3,5,5-pentaphenyl-1,3,5-tri-phospha-pentane trioxide (PPTPT) for U(VI) is quite unusual with very high values at both low and high concentrations of nitric acid, which is not observed for other types of extractants. Thus, this extractant might be promising for the selective extraction of U(VI) in very high concentrations of HNO3. (authors)

2008-09-15

65

Refining technique for converting coal to liquid fuel  

Science.gov (United States)

According to W. H. Wiser and A. G. Oblad, the program at the University of Utah to develop coal conversion techniques, which has received federal grants of $1.35 million since 1969, recently was awarded $425,000 from the U.S. Office of Coal Research for the development of catalysts for coal conversion and low-sulfur fuel oil production. In tests, 100 lb of coal have been converted into 95 lb of products composed of 30 lb liquid fuel like gasoline, 5 lb of diesel or fuel oil, 30 lb of gaseous fuel, and 30 lb of char.

1973-10-01

66

Nuclear Data Sheets for A = 177  

Energy Technology Data Exchange (ETDEWEB)

Evaluated spectroscopic data for all nuclei with mass number A = 177 and corresponding level schemes from radioactive decay and reaction studies are presented. Most of the new information since the previous evaluation of this mass chain consists of the decay of the recently discovered isotope [sup 177]Tm, and the level structure of [sup 177]Ir, [sup 177]Os, and [sup 177]Pt. The present evaluation supersedes the earlier one by Y. A. Ellis and B. Harmatz (75E107) published in Nuclear Data Sheets 16, 135 (1975).

1993-03-01

67

Nuclear Data Sheets for A = 177  

International Nuclear Information System (INIS)

Evaluated spectroscopic data for all nuclei with mass number A = 177 and corresponding level schemes from radioactive decay and reaction studies are presented. Most of the new information since the previous evaluation of this mass chain consists of the decay of the recently discovered isotope "1"7"7Tm, and the level structure of "1"7"7Ir, "1"7"7Os, and "1"7"7Pt. The present evaluation supersedes the earlier one by Y. A. Ellis and B. Harmatz (75E107) published in Nuclear Data Sheets 16, 135 (1975).

68

Determination of vapor pressures, enthalpies of sublimation, and enthalpies of fusion of benzenetriols  

Energy Technology Data Exchange (ETDEWEB)

Molar enthalpies of sublimation of 1,2,4-, 1,2,3-, and 1,3,5-tri-hydroxy-benzene, were obtained from the temperature dependence of the vapor pressure measured by the transpiration method. The molar enthalpies of fusion and molar heat capacities of these compounds were measured by DSC. The measured data sets of vaporization, sublimation and fusion enthalpies were checked for internal consistency. Strength of the inter- and intra-molecular hydrogen bonding in di- and tri-hydroxy-benzenes have been assessed.

2004-06-07

69

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although ...

1994-10-01

70

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although ...

1994-01-01

71

Electronic and geometric structure of transition-metal nanoclusters  

Energy Technology Data Exchange (ETDEWEB)

A massively-parallel ab initio computer code, which uses Gaussian bases, pseudopotentials, and the local density approximation, permits the study of transition-metal systems with literally hundreds of atoms. We present total energies and relaxed geometries for Ru, Pd, and Ag clusters with N = 55, 135, and 140 atoms; we also used the DMOL code to study 13-atom Pd and Cu clusters, with and without hydrogen. The N = 55 and 135 clusters were chosen because of simultaneous cubo-octahedral (fcc) and icosahedral (icos) sub-shell closings, and we find icos geometries are preferred. Remarkably large compressions of the central atoms are observed for the icos structures (up to 6% compared with bulk interatomic spacings), while small core compressions ({approx} 1 %) are found for the fcc geometry. In contrast, large surface compressive relaxations are found for the fcc clusters ({approx} 2-3% in average nearest neighbor spacing), while the icos surface ...

1996-08-01

72

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

73

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

74

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

75

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

76

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

77

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

78

The Separation of Humic Substances by Membrane Polysulfone Method  

International Nuclear Information System (INIS)

The separation of humic substances by polysulfone has been done. Thisinvestigation aims at separating the humic substances contained in theestuary environment. Because of without sample pre-treatment, cheap and easythis method has been to choice. At preliminary study proved that byincreasing the pressure until 50 psia, the yield of flux was 13.5 l/m"2.jamand the reject coefficient was 90.98%, so that polysulfone membrane isappropriate to be applied. More over the pressure could be increased morethan 50 psia. The feed concentration should be lower than 150 ppm, though thevolume should be greater. The pH condition should be alkaline (pH> 7), sinceat this condition the filtration process is easily conducted and the rejectcoefficient could reach 95.09%. (author)

2000-07-25

79

Synthesis by plasma and characterization of semiconductor compounds derived of polyacetylene; Sintesis por plasma y caracterizacion de compuestos semiconductores derivados del poliacetileno  

Energy Technology Data Exchange (ETDEWEB)

In this work it is made a study of the structure and electric properties of chlorate polyethylene (PE-CI) with double and simple bonds obtained by continuous plasma with resistive coupling to 13.5 MHz. The synthesis conditions are power between 10 and 14 W and pressure of (6-7) x 10{sup -2} Torr. The synthesized PE-Cl in that way is soluble in acetone what indicates that probably is formed of short chains and not it shows the generalized inter crossing that is presented in some syntheses by plasma and that it can degrade the electric properties of these polymers. The IR and XPS analysis show the vibration of the C-C, C=C and C-CI bonds. The morphology of the polymer after being dissolved shows a compact and flat configuration. The electric conductivity has an approximately lineal behavior in an interval of 35 to 90% of relative humidity. (Author)

2003-07-01

80

Structural characterization of liposomes made of diether archaeal lipids and dipalmitoyl-L-a-phosphatidylcholine  

British Library Electronic Table of Contents (United Kingdom)

The physicochemical properties of binary lipid mixtures of diether C25,25 lipids and dipalmitoyl-L-a-phosphatidylcholine (DPPC) were studied using photon correlation, fluorescence and electron paramagnetic resonance spectroscopy, and transmission electron microscopy. These two types of lipids can be mixed at all molar ratios to form unilamellar and multilamellar liposomes. Fluorescence anisotropy of 1,6-diphenyl-1,3,5-hexatrien in mixed liposomes indicates that the abrupt changes in order parameter in the hydrophobic part of bilayer membranes made of DPPC lipids disappears with increasing mol%C25,25 lipids. Electron paramagnetic resonance spectroscopy shows that at temperatures below 50^oC, the interfacial regions of membrane bilayer of mixed liposomes is more fluid than for pure DPPC lipo...

2011-01-01

 
 
 
 
81

Rapid self-assembly of Ni nanodots on Si substrate covered by a less-adhesive and heat-accumulated SiO_2 layers  

International Nuclear Information System (INIS)

Rapid self-aggregation of Ni nanodots on Si substrate covered with a thin SiO_2 buffered layer is investigated. The Ni nanodots can hardly self-aggregate on highly heat-dissipated Si substrate with a thermal conductivity of 148 W/m K. Adding a 200-A-thick SiO_2 buffer with an ultralow thermal conductivity of 1.35 W/m K prevents the formation of NiSi_2 compounds, enhances the heat accumulation, and releases the adhesion at Ni/Si interface, which greatly accelerates the self-assembly of Ni nanodots. Dense Ni nanodots with size and density of 30 nm and 7x10"1"0 cm"-"2, respectively, can be formatted after rapid thermal annealing at 850 deg. C for 22 s.

2006-08-14

82

Production of tetrazolium salts under conditions of phase-transfer catalysis  

Energy Technology Data Exchange (ETDEWEB)

Recently the authors showed that tetrazolium salts can be obtained during the oxidation of substituted 1,3,5-triarylformazans with potassium permanganate in a two-phase organic solvent-water system. The role of phase-transfer catalyst in this reaction is played by the tetrazolium salt, which is formed in a small amount as the result of oxidation of the formazan at the phase boundary. The method is distinguished by its extreme simplicity. However, the yield of the tetrazolium salts fluctuates within wide limits and does not exceed 62%. This is due to the fact that as the reaction proceeds the pH of the aqueous phase increases from 6 to 12. At the same time it is known that tetrazolium salts are unstable in aqueous alkaline solutions. They found that if the aqueous phase is replaced by aqueous hydrochloric acid (5 wt. %) the yields of the tetrazolium salts (Ia-g) are increased to 70-87%. For convenience of isolation the readily water-soluble tetrazolium chlorides ...

1988-06-20

83

Magnetic properties of RPd_2Si ternary compounds with (R = Gd, Tb, Dy, Ho and Er)  

International Nuclear Information System (INIS)

Magnetic properties of polycrystalline samples of RPd_2Si compounds (R = Gd, Tb, Dy, Ho and Er) are presented. The Gd and Tb based compounds are antiferromagnetic with Neel temperatures of 13.5 and 21 K respectively. For both compounds a metamagnetic transition is observed in low field. Moreover, in TbPd_2Si a transition between two different antiferromagnetic phases is observed at 8.5 K. The Dy, Ho and Er based compounds are ferromagnetic with Curie temperatures of 9, 3.5 ad 2.8 K respectively. The observed properties result from indirect exchange interactions and crystal field effects acting on rare earth ions which lie in a very low symmetry site. (author).

84

Magnetic properties of RPd/sub 2/Si ternary compounds with (R = Gd, Tb, Dy, Ho and Er)  

Energy Technology Data Exchange (ETDEWEB)

Magnetic properties of polycrystalline samples of RPd/sub 2/Si compounds (R = Gd, Tb, Dy, Ho and Er) are presented. The Gd and Tb based compounds are antiferromagnetic with Neel temperatures of 13.5 and 21 K respectively. For both compounds a metamagnetic transition is observed in low field. Moreover, in TbPd/sub 2/Si a transition between two different antiferromagnetic phases is observed at 8.5 K. The Dy, Ho and Er based compounds are ferromagnetic with Curie temperatures of 9, 3.5 ad 2.8 K respectively. The observed properties result from indirect exchange interactions and crystal field effects acting on rare earth ions which lie in a very low symmetry site.

1984-01-01

85

Iopentol in cardioangiography  

International Nuclear Information System (INIS)

Iopentol (350 mg I/ml) has been compared with iohixol (350 mg I/ml) in a double-blind randomized parallel group trial with 32 and 35 patients receiving iopentol and iohexol, respectively. Coronary angiography and left ventriculography were performed, and the mean total volume injected was 124 ml of iopentol and 135 ml of iohexol . There were no statistically significant differences regarding changes in heart rate and frequency of adverse advents, which were the primary parameters, between the two groups of patients. Blood pressure and ECG parameters revealed only minor fluctuations which were of no clinical relevance. The visualization of the coronary arteries and the left ventricle were the same with both contrast media, as was the diagnostic quality. The results support the use of iopentol in cardioangiography. (author). 1 ref.; 5 tabs.

86

Infrared study of the reaction of hydrogen with the (Co/sup 11/(CN)/sub 5/)/sup 3/- ion in deuterium oxide  

Energy Technology Data Exchange (ETDEWEB)

The effect of varying pD(11-13,7) on the reaction of hydrogen with (Co/sup 11/(CN)/sub 5/)/sup 3/- in deuterium oxide has been studied by using infrared spectroscopy to determine the ratio of (Co/sup 111/(CN)/sub 5/X)/sup 3/- (X=H,D) in the solids precipitated from the steady state under hydrogen. The results show that the uptake of hydrogen does not liberate a free proton and that the rate of (Co/sup 111/(CN)/sub 5/H)/sup 3/- -D/sub 2/,0 exchange increases with pD but becomes pD independent at pD 7 greater than 13,5.

1982-01-01

87

Incorporating phenolic compounds opens a new perspective to use zein films as flexible bioactive packaging materials  

British Library Electronic Table of Contents (United Kingdom)

To eliminate their classical brittleness and flexibility problems zein films were plasticized by incorporation of different phenolic acids (gallic acid (GA), p-hydroxy benzoic acid (HBA) or ferulic acids (FA)) or flavonoids (catechin (CAT), flavone (FLA) or quercetin (QU)). The use of GA, CAT, FA and HBA at 3 mg/cm2 eliminated the brittleness of films and gave highly flexible films showing elongations between 135% and 189%, while FLA and QU caused no considerable effect on film elongation. The films containing FA and HBA showed extreme swelling and lost their structural integrity when hydrated in distilled water. In contrast, CAT and GA containing films maintained their integrity following hydration. Most of the GA (up to 93%) and a considerable portion of CAT (up to 60%) in the films exis...

2011-01-01

88

Gamow-Teller and spin-dipole strength in the "4"0","4"8Ca(p vector,n vector) reactions at 135 MeV  

International Nuclear Information System (INIS)

Spin-flip probabilities for "4"8Ca(p vector, n vector)"4"8Sc reveal that at 0"0 the apparent continuum under and adjacent to the Gamow-Teller giant resonance is also primarily 1"+ strength. A comparison of "4"0Ca(p vector,n vector)"4"8Sc shows no discernable signature of Gamow-Teller strength in the region -30 > Q(MeV) > -45. The spin-flip component of the dipole resonance for "4"0Ca is broader than the non-spin-flip component. (orig.).

89

Excess and deviation properties for the binary mixtures of methylcyclohexane with benzene, toluene, p-xylene, mesitylene, and anisole at T = (298.15, 303.15, and 308.15) K  

International Nuclear Information System (INIS)

Experimental data on density, viscosity, and refractive index at T = (298.15, 303.15, and 308.15) K, while speed of sound values at T = 298.15 K are presented for the binary mixtures of (methylcyclohexane + benzene), methylbenzene (toluene), 1,4-dimethylbenzene (p-xylene), 1,3,5-trimethylbenzene (mesitylene), and methoxybenzene (anisole). From these data of density, viscosity, and refractive index, the excess molar volume, the deviations in viscosity, molar refraction, speed of sound, and isentropic compressibility have been calculated. The computed values have been fitted to Redlich-Kister polynomial equation to derive the coefficients and estimate the standard errors. Variations in the calculated excess quantities for these mixtures have been studied in terms of molecular interactions between the component liquids and the effects of methyl and methoxy group substitution on benzene ring.

2006-12-01

90

CHEMICAL TECHNOLOGY DIVISION. UNIT OPERATIONS SECTION MONTHLY PROGRESS REPORT, FEBRURARY 1963  

Science.gov (United States)

Development of a shear and leach complex for UO/sub 2/-SS clad fuel was continued with major emphasis on the operation of a rotary drum leacher. Flooding data for nozzle plate pulse columns at high A/O ratios are reported. Engineering tests of dissolution of Zr--6% U alloy with HF in molten salt demonstrated a dissolution rate of 0.8 to 1.5 mg/cm/sup 2//min. Subsequent fluorination with 100% F/sub 2/ proceeded at half times of 40 to 135 min. The results of a high level waste calcination (run R-72) made with formaldehyde treated simulated Purex waste are reported. (auth)

1963-10-01

91

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

92

FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color display tracks the ...

93

Dentritic morphology and microsegregation in directionally solidified superalloy, PWA-1480, single crystal: Effect of gravity; center director's discretionary fund report  

Energy Technology Data Exchange (ETDEWEB)

Primary dendrite spacings, secondary dendrite spacings, and microsegregation have been examined in PWA-1480 single crystal specimens which were directionally solidified during parabolic maneuvers on the KC-135 aircraft. Experimentally observed growth rate and thermal gradient dependence of primary dendrite spacings are in good agreement with predictions from dendrite growth models for binary alloys. Secondary dendrite coarsening kinetics show a reasonable fit with the predictions from an analytical model proposed by Kirkwood for a binary alloy. The partition coefficients of tantalum, titanium, and aluminum are observed to be less than unity, while that for tungsten and cobalt are greater than unity. This is qualitatively similar to the nickel base binaries. Microsegregation profiles experimentally observed for PWA-1480 superalloy show a good fit with Bower, Brody, and Flemings model developed for binary alloys. Transitions in gravity levels do not appear to affect ...

1990-11-01

94

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

95

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is carried out by FMS ...

2006-11-13

96

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

97

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

98

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...

2004-07-19

99

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

100

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...

1990-11-01

 
 
 
 
101

Two dimensional power spectral density measurements of X-rayoptics with the Micromap interferometric microscope  

Energy Technology Data Exchange (ETDEWEB)

A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The correction function has only one free parameter, ...

2005-05-12

102

Top physics: measurement of the tt-bar production cross section in p anti-p collisions at s**(1/2) = 1.96 tev using lepton + jets events with secondary vertex b-tagging  

Energy Technology Data Exchange (ETDEWEB)

We present a measurement of the t{bar t} production cross section using events with one charged lepton and jets from p{bar p} collisions at a center-of-mass energy of 1.96TeV. In these events, heavy flavor quarks from top quark decay are identified with a secondary vertex tagging algorithm. From 162 pb{sup -1} of data collected by the Collider Detector at Fermilab, a total of 48 candidate events are selected, where 13.5 {+-} 1.8 events are expected from background contributions. We measure a t{bar t} production cross section of 5.6{sub -1.1}{sup _1.2}(stat.){sub -0.6}{sup +0.9}(syst.)pb.

2005-04-07

103

The integrity concept of the rack drive electric power steering system; Das Sicherheitskonzept der elektromechanischen Servolenkung mit Zahnstangenantrieb  

Energy Technology Data Exchange (ETDEWEB)

Today electric power steering systems are regularly considered by the car manufacturers as an alternative to a conventional hydraulic power steering system in the development of new vehicle platforms. Simplified vehicle assembly and the potential to contribute to the reduction of the vehicle's energy consumption are the main motivation for this. The performance of the systems available at present with 13.5 V supply voltage will be improved even more as soon as the future 42 V vehicle electrical systems are available. Like most active chassis systems, electric power steering has to meet the highest safety requirements imaginable. This article summarizes the safety philosophy of the TRW rack drive Electric Power Steering system. (orig.) [German] Elektromechanische Servolenkungen werden heute bei der Entwicklung neuer Fahrzeuge als Alternative zur konventionellen hydraulischen Servolenkung in Betracht gezogen. Die vereinfachte Fahrzeugmontage und das ...

1999-11-01

104

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

105

Present status of the C-band activities at KEK  

International Nuclear Information System (INIS)

We have already developed three conventional and one periodic permanent (PPM) type 50-MW class klystrons, a smart modulator, and the first HOM-free accelerator structure (Choke-mode type, full-scale high power model). A very stable ceramic high voltage monitor was successfully tested up to 367-kV with a 4.5-#mu#sec pulse. A new C-band SiC type high power rf-load, advancing the power handling capability up to 50-MW is now being designed. It should have excellent mass production characteristics as it uses circularly symmetric TM_0_1_1 chained cavities. The first high power prototype of an rf compressor cavity made of a low thermal expansion material (super Invar) was designed to provide stable operation even with a very high Q of 200-k, it was successfully tested the output rf power up to 135-MW, 0.5-#mu#sec pulse width and 50-pps repetition rate. The C-band linac rf-system will be used for the SASE-FEL (SCSS) production project at SPring-8, but SCSS will also serve ...

2004-08-04

106

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

International Nuclear Information System (INIS)

The dependence of the photoluminescent properties of In_0_._4_8(Al_yGa_1_-_y)_0_._5_2P alloys (0#<=#y#<=#0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ''ordered'' domains and the ''disordered'' matrix) is the dominant photoluminescence broadening mechanism. This investigation has allowed a significant optimization of the optical properties of these materials, including the ...

107

On the stability of Innovar, a neuroleptic analgesic, for cardiovascular experiments.  

Science.gov (United States)

The effects of 0.2 and 0.5 mL/kg Innovar (a neuroleptic analgesic) on cardiovascular functions and reflexes in rabbits were measured. We recorded the effects of Innovar on arterial pressure, heart rate, respiration rate, ventricular contractility, arterial oxygen tension, as well as the drug's effects on the bradycardia and vasoconstrictor response to cigarette smoke stimulation of the nose (the so-called "nasopharyngeal reflex"). In animals given 0.2 mL/kg Innovar, all steady state cardiovascular variables had returned to pre-Innovar levels in 45 min, as had the efficacy of the nasopharyngeal reflex. In animals given 0.5 mL/kg Innovar, all steady state cardiovascular variables, except PaO2, were slightly but significantly depressed for up to 135 min after injection. The nasopharyngeal reflex returned to normal within 90 min. Because of the calmative and analgesic effects of Innovar, and its only moderate effects on cardiovascular functions and reflexes, we feel it ...

1981-11-01

108

Management of Ewing's sarcoma  

International Nuclear Information System (INIS)

Forty cases of Ewing's sarcoma of various sites had attended the Department of Radiotherapy at the Wanless Hospital and the Miraj Medical Centre, attached to the Government Medical College, Miraj, Maharashtra, from January, 1970 through December, 1979. There were 28 male patients and 12 female patients in the series with a male to female ratio of 2.3:1. The youngest patient in the series was a female of 6 years of age with the tumour in the scapula and the oldest patient was a 32-year-old male with a lesion in the metacarpal bone. Sixty per cent of the cases were seen in the second decade. The average age of the patients was 13.5 years. The bones of the lower extremities were most commonly involved with the highest number (35 per cent) of the cases occurring in the femur. Involvement of the bones of the right side of the body was almost equal to that of the left side. Swelling over the site of the lesion and pain over the swelling were the most common complaints ...

109

Magnetospheric Emissions from the Planet Orbiting tau Boo: A Multi-Epoch Search  

CERN Document Server

All of the solar system gas giants produce electron cyclotron masers, driven by the solar wind impinging on their magnetospheres. Extrapolating to the planet orbiting tau Boo, various authors have predicted that it may be within the detection limits of the 4-meter wavelength (74 MHz) system on the Very Large Array. This paper reports three epochs of observations of tau Boo. In no epoch do we detect the planet; various means of determining the upper limit to the emission yield single-epoch limits ranging from 135 to 300 mJy. We develop a likelihood method for multi-epoch observations and use it to constrain various radiation properties of the planet. Assuming that the planet does radiate at our observation wavelength, its typical luminosity must be less than about 10^{16} W, unless its radiation is highly beamed into a solid angle Omega << 1 sr. While within the range of luminosities predicted by various authors for this planet, this value is lower than recent ...

2007-01-01

110

MRS of normal and impaired fetal brain development  

International Nuclear Information System (INIS)

Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are illustrated.

2006-02-01

111

Local control and sequelae following irradiation of Ewing's sarcoma  

International Nuclear Information System (INIS)

135 patients with histologically proven Ewing's sarcoma, treated at the Institute Gustave Roussy between 1960-1974 were reviewed in order to establish the effectiveness and the complications associated with radiotherapy. In 133 patients, a dose of at least 60 Gy for long bones, 55 Gy for flat bones and 45 Gy for vertebrae was given. 26 major complications (of which more than one occured in certain patients) were observed: 12 cases of growth retardation, loss of joint function in 7 cases, 3 fractures, 2 osteonecroses, 2 cases of delayed healing, one massive soft tissue fibrosis, 1 abdominocutaneous fistula, 2 cases of symptomatic pulmonary fibrosis with associated infection, 2 cases of radiation enteropathy, 2 of mammary hypoplasia and 1 osteosarcoma developing in an irradiated zone. These complications necessitated 12 surgical interventions, including 4 disarticulations or amputations. The incidence of complications can be related to the age of the patient and to ...

112

Korrelation von Tonschwellenaudiogramm und H?rverlust f?r Zahlen  

British Library Electronic Table of Contents (United Kingdom)

Zusammenfassung Hintergrund Die vorliegende Arbeit untersucht, welche Frequenzkombination f?r die Berechnung der mittleren H?rverluste im Tonschwellenaudiogramm am besten mit dem H?rverlust f?r Zahlen im Sprachaudiogramm korreliert, da in der Literatur verschiedene Rechenvarianten f?r diese gutachterliche Plausibilit?tspr?fung beschrieben werden. Es wurden die 3?Rechenvarianten A (250, 500 und 1000?Hz), B (500 und 1000?Hz) und C (500, 1000 und 2000?Hz) verglichen. Methoden Die Audiogramme von 80?Normalh?rigen, 106?Schwerh?rigen und 135 zu Begutachtenden wurden retrospektiv analysiert. Die Differenzen der Mittelwerte aus dem Tonschwellenaudiogramm und dem H?rverlust f?r Zahlen wurden f?r das rechte und linke Ohr getrennt in den 3?Patientenkollektiven berechnet und statistisch verglichen. Er...

2011-01-01

113

Inelastic Neutron Scattering on an Mn10 Supertetrahedron: Assessment of Exchange Coupling Constants, Ferromagnetic Spin Waves and an Analogy to the Hckel Method  

British Library Electronic Table of Contents (United Kingdom)

Abstract The synthesis, crystal structure and magnetic characterisation by magnetisation and inelastic neutron scattering (INS) of a mixed-valent Mn10 supertetrahedral aggregate [MnIII6MnII4(4-O)4(3-N3)3(3-Br)(Hmpt)6(Br)]Br0.7(N3)0.3-2-MeOH-3-MeCN (1) (H3mpt=3-methylpentan-1,3,5-triol) is reported. The magnetic core of the molecule can be described as an octahedron of six S=2 MnIII ions with four faces, each capped by a S=5/2 MnII ion such as to form the supertetrahedron. Unlike most related complexes, the molecular symmetry is slightly reduced from approximately Td to C3. The magnetic data reveal a total spin of S=22 in the ground state due to ferromagnetic exchange couplings within the molecule. The combined INS and magnetic data permits the accurate determination of the exchange couplin...

2011-01-01

114

Extended radio emission in MOJAVE Blazars: Challenges to Unification  

CERN Document Server

We present the results of a study on the 1.4 GHz kpc-scale radio emission in the complete flux density limited MOJAVE sample, comprising 135 radio-loud AGNs. While extended emission is detected in the majority of the sources, about 7% of the sources exhibit only radio core emission. Many BL Lacs exhibit extended radio power and kpc-scale morphology typical of powerful FRII jets, while a substantial number of quasars possess radio powers intermediate between FRIs and FRIIs. This poses challenges to the simple radio-loud unified scheme, which links BL Lacs to FRIs and quasars to FRIIs. We find a significant correlation between extended radio emission and pc-scale jet speeds: the more radio powerful sources possess faster jets. This indicates that the 1.4 GHz (or low frequency) radio emission is indeed related to jet kinetic power. Various properties such as extended radio power and apparent pc-scale jet speeds vary smoothly between different blazar subclasses, ...

2010-01-01

115

Effect of processing on pirimiphos-methyl residues in stored peanuts  

International Nuclear Information System (INIS)

Peanut grains (1500g) were placed in a jute sack which was sprayed with "1"4C- pirimiphos-methyl [0-2-diethylamino-6-methylpyrimidin-4-yl-O, O-dimethylphosphorothiate, "1"4C-labelled in the 2-position of the pyrimidine ring]; total dose 5.55 MBq + 22.5 mg cold insecticide. As in practice, the sack was stored under local conditions for 36 weeks. The grain was crushed, dried at 50 deg. C for 2 hours and soxhlet extracted with chloroform-methanol (1:1). The crude oil was then subjected to sequential processes of alkali treatment, bleaching and deodorization. The initial residue concentration in the crude oil (5.66 ppm) was reduced to 4.50 ppm through alkali treatment and declined further to 3.78 ppm after bleaching. Deodorization removed a substantial amount of "1"4C-residues leaving 1.35 ppm in the refined oil. It may be concluded that simulated commercial processing of crude oil were capable of removing 76% of pirimiphos-methyl and/or products. The most efficient ...

1995-08-01

116

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

117

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

118

Cross-section measurements for (n, 2a) (n, p) and (n, #alpha#) reactions on strontium isotopes at the neutron energy about 14 MeV  

International Nuclear Information System (INIS)

Cross-sections for "8"4Sr(n, 2n)"8"3Sr, "8"6Sr(n, 2n)"8"5"mSr, "8"6Sr(n, 2n)"8"5Sr, "8"8Sr(n, 2n)"8"7"mSr, "8"4Sr(n, p)"8"4Rb, "8"6Sr(n, p)"8"6Rb, "8"8Sr(n, p)"8"8Rb and "8"8Sr(n, #alpha#)"8"5"mKr reactions have been measured at neutron energies from 13.5 to 14.6 MeV using activation technique and by means of #gamma#-ray spectrometry. The neutron flux was determined using the monitor reaction "9"3Nb(n, 2n)"9"2"mNb and the neutron energies were measured by the method of cross-section ratios for "9Zr(n, 2n)"8"9Zr to "9"3Nb (n, 2n)"9"2"mNb reactions. The results of present work are compared with data published previously.

2006-01-01

119

Constituents of fruit pulp of Maytenus salicifolia and complete 1D/2D NMR data of 3?-hydroxy-D:B-friedo-olean-5-ene  

British Library Electronic Table of Contents (United Kingdom)

A mixture of long-chain hydrocarbons constituted by nonacosane (29C, 7.5%), hentriacontane (31C, 48.3%), and tritriacontane (33C, 30.1%), the ester 1?-acetyloxymethylpentacosa-20?-enyl 10-hydroxydecanoate (2), ?-amyrin (3), friedelin (4), and lupeol (5), and 3?-hydroxy-D:B-friedo-olean-5-ene (6) were identified as constituents of fruits of Maytenus salicifolia Reissek (Celastraceae). The structural formula and the stereochemistry of compound 6 were established by the data obtained through 1H and 13C NMR spectroscopy, including DEPT-135 and 2D (HMQC, HMBC, and NOESY) experiments. By analysis of the spectral data, it was possible to correct seven chemical shift assignments of compound 6, which were erroneous attributed and published in the scientific literature.

2010-01-01

120

Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. The heat transfer correlations of the code should be revised to ...

1988-01-01

 
 
 
 
121

Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5  

International Nuclear Information System (INIS)

Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. The heat transfer correlations of the code should be revised to take into ...

1988-11-04

122

Comparison of Students' Success in an International Technology Certificate Program  

Science.gov (United States)

There has been a rapid increase in the number of technology certificate programs offered around the world in the last decade. While designing, developing, and implementing these programs little or no consideration is given to geographical, cultural and developmental differences between different regions of the world. This study investigates the students' success in the Cisco Certified Network Associate (CCNA) program--a unique model combining technology-supported learning with local instruction world-wide. The purpose of this study is to investigate how demographic, ability, and motivational factors impact student success in different regions of the world when the curriculum and teaching materials are the same for all students and teachers. 368,159 students who completed the technology course from August 2004 to December 2005 in 5,948 academies in 135 countries were examined. Based on ANOVA and regression, results show that prior achievement, technology skills, and ...

2007-12-01

123

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...

2005-10-23

124

Cloning and mapping of the mouse {alpha}7-neuronal nicotinic acetylcholine receptor  

Energy Technology Data Exchange (ETDEWEB)

We report the isolation of cDNA clones for the mouse {alpha}7 neuronal nicotinic acetylcholine receptor subunit (gene symbol Acra7), the only nicotinic receptor subunit known to bind a-bungarotoxin in mammalian brain. This gene may have relevance to nicotine sensitivity and to some electrophysiologic findings in schizophrenia. The mouse {alpha}7 subunit gene encodes a protein of 502 amino acids with substantial identity to the rat (99.6%), human (92.8%), and chicken (87.5%) amino acid sequences. The {alpha}7 gene was mapped to mouse chromosome 7 near the p locus with the following gene order from proximal to distal: Myod1-3.5 {+-}1.7 cM-Gas2-0.9 cM {+-} 0.9 cM-D7Mit70-1.8 {+-} 1.2 cM- Acra7-4.4 {+-}1.0 cM-Hras1-ps11/Igf1r/Snrp2a. The human gene was confirmed to map to the homologous region of human chromosome 15q13-q14. 26 refs., 3 figs.

1995-03-20

125

Carbon pools and flux in the forests of Korea  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the estimated the rate of carbon accumulation in the woody biomass and total carbon storage in the forests including trees, soil and litter in Korea. The relevant data come from the Statistical Yearbook of Forestry and major results of the studies on forest biomass in Korea. Most of the forests, which has been denuded or degraded during the 2nd World War and the Korean War, were recovered through ``Reforestation Project(1973-1987)`` and natural regeneration. So, now they are mostly young secondary forests and grow rapidly. Total carbon removal by forests is estimated at 8.1 million tonnes of carbon(MtC) and the carbon emission by commercial harvesting at 0.9 MtC. therefore, the forests in Korea play an essential role as a net carbon sink. The annul net carbon removal is 7.2 MtC and accounts for about 11.0% of total carbon emissions in energy sector of Korea. The carbon storage in the forests is 589.9 MtC, 22.4% of that stored in trees, 64.1% in soil, and ...

1998-04-01

126

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various multilayer mirrors for ...

2008-04-01

127

Anaerobic degradation of DCM diffusing through clay  

Energy Technology Data Exchange (ETDEWEB)

Two series of diffusion tests were performed to examine the degradation of dichloromethane (DCM) as it diffuses through clay. The first series showed the use of a synthetic leachate with no significant initial bacterial population diffusing through a plug of intact clay; there was an induction period of 95--135 d, during which diffusion was as expected in the absence of degradation, followed by a second stage, where degradation occurred with an apparent half-life of less than 55 d at a temperature of 24 C. The second series of tests examined the diffusion of an actual leachate from the Keele Valley Landfill (KVL) (which provided both nutrients and a source of bacteria), through a compacted clay. In these tests, the induction period was reduced to 40--60 d, after which the apparent half-life was 20 d or less at 27 C. The diffusion coefficient for DCM was approximately 8 {times} 10{sup {minus}10} m{sup 2}/s, with partitioning coefficient K{sub d} = 1.5 cm{sup 3}/g. ...

1997-12-01

128

Ammonia Fiber Expansion (AFEX) Pretreatment, Enzymatic Hydrolysis, and Fermentation on Empty Palm Fruit Bunch Fiber (EPFBF) for Cellulosic Ethanol Production  

British Library Electronic Table of Contents (United Kingdom)

Empty palm fruit bunch fiber (EPFBF), a readily available cellulosic biomass from palm processing facilities, is investigated as a potential carbohydrate source for cellulosic ethanol production. This feedstock was pretreated using ammonia fiber expansion (AFEX) and enzymatically hydrolyzed. The best tested AFEX conditions were at 135??C, 45?min retention time, water to dry biomass loading of 1:1 (weight ratio), and ammonia to dry biomass loading of 1:1 (weight ratio). The particle size of the pretreated biomass was reduced post-AFEX. The optimized enzyme formulation consists of Accellerase (84??L/g biomass), Multifect Xylanase (31??L/g biomass), and Multifect Pectinase (24??L/g biomass). This mixture achieved close to 90% of the total maximum yield within 72?h of enzymatic hydrolysis. Fer...

2010-01-01

129

Alternate Tunings for the Linac Coherent Light Source Photoinjector  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the 1 nC case. In the second ...

2006-03-17

130

Activation cross sections for reactions induced by 14 MeV neutrons on natural ruthenium  

Science.gov (United States)

Cross sections for (n,2n) (n,p) (n,{alpha}), and (n,d*){sup 1} reactions have been measured on ruthenium isotopes at the neutron energies of 13.5 to 14.8 MeV using the activation technique in combination with high-resolution gamma-ray spectroscopy. Data are reported for the following reactions: {sup 104}Ru(n,2n){sup 103}Ru, {sup 98}Ru(n,2n){sup 97}Ru, {sup 96}Ru(n,2n){sup 95}Ru, {sup 96}Ru(n,p){sup 96}Tc{sup g}, {sup 96}Ru(n,p){sup 96}Tc{sup m}, {sup 104}Ru(n,p){sup 104}Tc, {sup 102}Ru(n,p){sup 102}Tc{sup m}, {sup 104}Ru(n,{alpha}){sup 101}Mo, {sup 102}Ru(n,{alpha}){sup 99}Mo, {sup 96}Ru(n,{alpha}){sup 93}Mo{sup m}, and {sup 96}Ru(n,d*){sup 95}Tc{sup m}. Results were discussed and compared with the previous works.

2007-11-15

131

Activation cross sections for reactions induced by 14 MeV neutrons on natural ruthenium  

International Nuclear Information System (INIS)

Cross sections for (n,2n) (n,p) (n,#alpha#), and (n,d*)"1 reactions have been measured on ruthenium isotopes at the neutron energies of 13.5 to 14.8 MeV using the activation technique in combination with high-resolution gamma-ray spectroscopy. Data are reported for the following reactions: "1"0"4Ru(n,2n)"1"0"3Ru, "9"8Ru(n,2n)"9"7Ru, "9"6Ru(n,2n)"9"5Ru, "9"6Ru(n,p)"9"6Tc"g, "9"6Ru(n,p)"9"6Tc"m, "1"0"4Ru(n,p)"1"0"4Tc, "1"0"2Ru(n,p)"1"0"2Tc"m, "1"0"4Ru(n,#alpha#)"1"0"1Mo, "1"0"2Ru(n,#alpha#)"9"9Mo, "9"6Ru(n,#alpha#)"9"3Mo"m, and "9"6Ru(n,d*)"9"5Tc"m. Results were discussed and compared with the previous works.

2007-11-01

132

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

133

A hydroxide mixture as working fluid for absorption heat pumps  

Energy Technology Data Exchange (ETDEWEB)

Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process with this solution. The ...

1996-11-01

134

#beta#-delayed proton decays near the proton drip line  

International Nuclear Information System (INIS)

In order to improve the measuring efficiency, a 'proton-gamma' coincidence technique in combination with a He-jet tape transport system was proposed and employed to identify the #beta#-delayed proton precursors. The study of #beta#-delayed proton decays near the proton drip line by using the 'proton-gamma' coincidence technique over the last 5 years at the Institute of Modern Physics, Lanzhou, China, was summarized. New #beta#-delayed proton precursors "1"2"1Ce, "1"2"5Nd, "1"2"8Pm, "1"2"9Sm, "1"3"5Gd, "1"3"7Gd, "1"3"9Dy, "1"4"2Ho, and "1"4"9Yb in the rare-earth region along a speculated proton drip line were synthesized and identified for the first time. The #beta#-delayed proton decays of "8"1Zr, "8"5Mo, "8"9Ru, and "9"3Pd in T_z=1/2 series as well as "9"2Rh in T_z=1 series were observed.

2002-04-02

135

WLUP3.0, 69 and 172 Group Cross Section Libraries for WIMS  

International Nuclear Information System (INIS)

Description or function: WLUP contains validated WIMS-D formatted cross section libraries in 69 and 172 energy group structures for nuclear reactor calculations. Materials from recently released evaluated nuclear data libraries are included. The NJOY nuclear data processing system was applied for generating the cross section files following the models and conventions built into the WIMS-D lattice code. The relevant features for the WIMS users are: - Energy group structures: 69 and 172 energy groups. - List of materials: WIMS ID, general information, source of data. - Cross sections: 69 and 172 group plots. - Resonance data: WIMS ID, temperature, background cross sections. - Goldstein-Cohen factors: Goldstein-Cohen lambda values. - Thermal scattering data: thermal scattering laws and P1 matrixes. - Fission spectrum: fission spectrum data. - Burnup data: burnup chains. - Fission product yields: fission yield tables. - Pseudo lumped fission product: Description of pseudo fission product. ...

136

Zero-G two phase flow regime modeling in adiabatic flow  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package ...

1993-01-15

137

Zero-G two phase flow regime modeling in adiabatic flow  

International Nuclear Information System (INIS)

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A ampersand M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate measurements of the vapor and liquid flow streams. The experimental ...

1993-01-10

138

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

139

Study of nanocrystallization in FINEMET alloy by active screen plasma nitriding  

International Nuclear Information System (INIS)

The nanocrystallization process of amorphous Fe_7_3_._5Si_1_3_._5B_9Nb_3Cu_1 was investigated by active screen plasma nitriding (ASPN) treatment at temperatures ranging from 410 "oC to 560 "oC for 3 h in two gas mixtures of 75% N_2-25% H_2 and 25% N_2-75% H_2 at 5 mbar atmosphere. The amorphous ribbons were then annealed under vacuum at the same time and temperatures mentioned above. The structure of the samples was analyzed using various techniques such as X-ray diffraction (XRD), atomic force microscopy (AFM) and differential scanning calorimetry (DSC). Microhardness measurements, electrical resistivity and Vibrating Sample Magnetometer (VSM) were used to study mechanical, electrical and magnetic properties of the samples, respectively. It was observed that the ASPN treatment leads to finer grain size and higher crystalline volume fraction and modifies the structural features of Fe(Si) phase. The Fe(Si) lattice parameter for the nitrided samples decreased up to ...

2010-02-18

140

Strontium removal from caustic carbonate waste solutions using carrier coprecipitation  

Energy Technology Data Exchange (ETDEWEB)

A carrier coprecipitation procedures has been developed for the removal of radioactive strontium from caustic liquid low-level waste (LLLW) generated at Oak Ridge National Laboratory. The two-step treatment process involves the addition of normal Sr (as SrCl{sub 2}) to the waste matrix, which is composed primarily of 0.3 M NaOH and 0.6 M Na{sub 2}CO{sub 3}. The active Sr equilibrates with the normal Sr carrier and coprecipitates as SrCO{sub 3} at pH 13. A liquid/solid separation is made before the pH of the supernate is reduced to pH 8 with sulfuric acid. During the neutralization step, the aluminum is the waste precipitates as Al(OH){sub 3}. Further Sr decontamination is achieved as traces of active Sr sorb to the Al(OH){sub 3} that precipitates during the neutralization step. A final liquid/solid separation is made at pH 8 to remove the sorbed active Sr. Maximum Sr decontamination of the LLLW is obtained when at least 50 ppm normal Sr is added to the waste. Because formation of the ...

1994-12-31

 
 
 
 
141

Reclamation of acidic copper mine tailings using municipal biosolids  

Energy Technology Data Exchange (ETDEWEB)

Reclamation of copper mine tailings in a cost effective, successful, and sustainable manner is an ongoing area of evaluation in the arid southwest. A study was initiated in September, 1996 near Hayden, Arizona to evaluate the use of municipal biosolids for reclaiming acidic copper mine tailings (pH of 2.5 to 4.0). The main objectives of the study were to (1) define an appropriate level of biosolids application for optimum plant growth, and (2) evaluate the effects of green waste and lime amendments. The experiment was a randomized complete block design with four biosolid rates of 20, 70, 100 and 135 dry tons/acre, three amendment treatments (none, green waste, and green waste plus lime); with three replications. Non-replicated controls (no treatment, green waste only and lime only) were included for comparison. Shortly after biosolids incorporation to a depth of 10--12 inches, composite soil samples (0--12 inches) of each plot were taken. Biosolids incorporation ...

1998-12-31

142

RESTORING SUSTAINABLE FORESTS ON APPALACHIAN MINED LANDS FOR WOOD PRODUCTS, RENEWABLE ENERGY, CARBON SEQUESTRATION, AND OTHER ECOSYSTEM SERVICES  

Energy Technology Data Exchange (ETDEWEB)

The overall purpose of this project is to evaluate the biological and economic feasibility of restoring high-quality forests on mined land, and to measure carbon sequestration and wood production benefits that would be achieved from forest restoration procedures. In this quarterly report, we present a preliminary comparison of the carbon sequestration potential of forests growing on 14 mined sites in a seven-state region in the Midwestern and Eastern Coalfields. Carbon contents of these forests were compared to adjacent forests on non-mined land. The study was installed as a 3 x 3 factorial in a random complete block design with three replications at each location. The treatments include three forest types (white pine, hybrid poplar, mixed hardwood) and three silvicultural regimes (competition control, competition control plus tillage, competition control plus tillage plus fertilization). Each individual treatment plot is 0.5 acres. Each block of nine plots requires 4.5 acres, and the ...

2004-06-04

143

Quaternary faults near the proposed Eagle Flat low-level radioactive waste repository, Trans-Pecos Texas  

Science.gov (United States)

The Eagle Flat basin, an intermontane basin in Trans-Pecos Texas, is being considered as a possible site for the Texas repository of low-level radioactive wastes. Intermontane basins and associated normal faults formed in response to Basin and Range tectonism that began about 24 Ma ago. The most active late Tertiary and Quaternary faults occur within the Hueco Bolson (HB) and the Salt Basin/Salt Flat/Lobo Valley, west and east, respectively, of the proposed repository. Several faults of the southeast HB which are within 50 km of the site, displace middle Pleistocene deposits 10 to 24 m. The most recent surface rupture in the southeast HB probably occurred on the Amargosa fault during the Holocene. Upper Pleistocene deposits are offset 2.5 to 4.5 m, and middle Pleistocene deposits are displaced 24 m. Fault scarps within 50 km east of the proposed repository are associated with faults bounding the Salt Basin/Salt Flat/Lobo Valley. In the southern Salt Basin and northern Salt Flat, faults ...

1992-01-01

144

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

Energy Technology Data Exchange (ETDEWEB)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 {plus minus} 0.16 in patients with NEO and 1.08 {plus minus} 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 {plus minus} 0.24 in NEO patients and 1.05 {plus minus} 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative ...

1991-06-01

145

Quantitative bone and 67Ga scintigraphy in the differentiation of necrotizing external otitis from severe external otitis  

International Nuclear Information System (INIS)

Qualitative technetium Tc 99m bone scintigraphy using phosphate compounds and gallium 67 scintigraphy were described as a helpful means in diagnosing necrotizing external otitis (NEO). They were, however, claimed to be nonspecific. Quantitative Tc 99m methylene diphosphonate bone scintigraphy and gallium 67 scintigraphy were performed in eight patients with NEO and in 20 patients with severe external otitis, in order to prove usefulness of scintigraphy in the diagnosis of NEO. Ratios of lesion to nonlesion for bone scintigraphy were 1.67 #+-# 0.16 in patients with NEO and 1.08 #+-# 0.09 in patients with severe external otitis, and for gallium 67 scintigraphy they were 1.35 #+-# 0.24 in NEO patients and 1.05 #+-# 0.03 in patients with severe external otitis. There was no difference in uptake between diabetic patients with severe external otitis and nondiabetic patients. The scintigraphic studies were also evaluated using a qualitative scoring method (scores 0 to ...

146

Polyp measurement and size categorisation by CT colonography: effect of observer experience in a multi-centre setting  

Energy Technology Data Exchange (ETDEWEB)

The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five percent limits of agreement were relatively wide for all observer groups, and had sufficient span to encompass different size ...

2006-08-15

147

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

Science.gov (United States)

The dependence of the photoluminescent properties of In{sub 0.48}(Al{sub {ital y}}Ga{sub 1{minus}{ital y}}){sub 0.52}P alloys (0{le}{ital y}{le}0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ordered'' domains and the disordered'' matrix) is the dominant photoluminescence broadening mechanism. This investigation has allowed a significant ...

1992-12-01

148

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

Energy Technology Data Exchange (ETDEWEB)

The dependence of the photoluminescent properties of In{sub 0.48}(Al{sub {ital y}}Ga{sub 1{minus}{ital y}}){sub 0.52}P alloys (0{le}{ital y}{le}0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ordered'' domains and the disordered'' matrix) is the dominant photoluminescence broadening mechanism. This investigation has allowed a significant optimization ...

1992-12-01

149

Nanoscale microstructure and magnetic properties of melt-spun Sm(Co{sub 0.725}Fe{sub 0.1}Cu{sub 0.12}Zr{sub 0.04}B{sub 0.015}){sub 7.4} ribbons  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the nanocrystalline microstructure and the hard magnetic properties of Sm(Co{sub 0.725}Fe{sub 0.1}Cu{sub 0.12}Zr{sub 0.04}B{sub 0.015}){sub 7.4} melt-spun ribbons. The coercivity (H{sub c}) of the as-spun ribbons increased with the wheel surface speed from 2.8kOe for 10m/s to 14.5kOe for 40m/s. The post-annealing of the melt-spun ribbons from 700 to 900 deg. C for 10min did not lead to a substantial increase of H{sub c}. However, after isothermal aging at 820 deg. C and subsequent slow cooling (0.5 deg. C/min) to 120 deg. C, H{sub c} increased from 2.8 to 10.9kOe for 10m/s, while it decreased from 14.5 to 13.5kOe for 40m/s ribbons. The grain size of the melt-spun ribbon reduced with structural transformation from 2:17H (Th{sub 2}Ni{sub 17}-hexagonal type) to 1:7H (TbCu{sub 7}-hexagonal type) as the wheel surface speed was increased. Three-dimensional atom probe analysis showed a boron enriched precipitate at the grain boundaries in the as-spun ...

2005-08-15

150

Nanoscale microstructure and magnetic properties of melt-spun Sm(Co_0_._7_2_5Fe_0_._1Cu_0_._1_2Zr_0_._0_4B_0_._0_1_5)_7_._4 ribbons  

International Nuclear Information System (INIS)

We have investigated the nanocrystalline microstructure and the hard magnetic properties of Sm(Co_0_._7_2_5Fe_0_._1Cu_0_._1_2Zr_0_._0_4B_0_._0_1_5)_7_._4 melt-spun ribbons. The coercivity (H_c) of the as-spun ribbons increased with the wheel surface speed from 2.8kOe for 10m/s to 14.5kOe for 40m/s. The post-annealing of the melt-spun ribbons from 700 to 900 deg. C for 10min did not lead to a substantial increase of H_c. However, after isothermal aging at 820 deg. C and subsequent slow cooling (0.5 deg. C/min) to 120 deg. C, H_c increased from 2.8 to 10.9kOe for 10m/s, while it decreased from 14.5 to 13.5kOe for 40m/s ribbons. The grain size of the melt-spun ribbon reduced with structural transformation from 2:17H (Th_2Ni_1_7-hexagonal type) to 1:7H (TbCu_7-hexagonal type) as the wheel surface speed was increased. Three-dimensional atom probe analysis showed a boron enriched precipitate at the grain boundaries in the as-spun ribbons, which acts as the grain growth ...

2005-08-01

151

Measurement results of BHTV logging at the geothermal well. 1; Chinetsusei ni okeru BHTV kenso no sokutei kekka. 1  

Energy Technology Data Exchange (ETDEWEB)

In association with excavation of the No. 135 steam producing well in the Onikubi geothermal power plant in Miyagi Prefecture, shapes of production zones and drilling-induced fracture (DIF) were acquired from the borehole televiewer (BHTV) data. The BHTV logging shoots sound waves onto well walls of wells filled with fluid and detects the reflection waves to investigate the state of the well walls. Vertical fracture with opening lengths from 2 to 3 m were found at depths of about 1232 m and 1312 m. Water run-off has occurred at a depth of about 1312 m during the excavation, to which these vertical fractures might have contributed possibly. In depths of about 1232 m and 1312 m, fractures inclining toward north-east direction and south-west direction are predominant. Some fractures in the depth of about 1333 m incline toward east-south-east direction and west-north-west direction. Fracture inclination azimuth in all of the present logging sections is predominantly in ...

1997-05-27

152

Inherited partial direct duplication of 11q: First report and possible association with a midline developmental field defect  

Energy Technology Data Exchange (ETDEWEB)

A 36-year-old woman underwent amniocentesis for advanced maternal age. The fetal karyotype had an extra dark staining G band on the long arm of chromosome 11 with no other identifiable abnormalities. FISH studies using a chromosome 11 paint probe confirmed the origin of the extra band. The abnormality was identified as a partial duplication of 11q: 46,XX dir dup (11)(q13.5q21) or (q21q23.1). The specific duplicated band could not be identified with certainty. Detailed fetal sonograms were normal. Family studies revealed the identical duplication in the mother but normal karyotypes in both maternal grandparents. The mother had strabismus and a short tongue frenulum which required surgical correction. Menses occurred late in adolescence and complete development of secondary sexual characteristics was delayed until adulthood. An infertility evaluation revealed duplication of the uterus, cervix, and vagina. An evaluation for metorrhagia identified a pituitary adenoma ...

1994-09-01

153

Graft copolymers of methyl methacrylate and poly([R]-3-hydroxybutyrate) macromonomers as candidates for inclusion in acrylic bone cement formulations: Compression testing.  

Science.gov (United States)

Graft copolymers of methyl methacrylate and biodegradable, biocompatible bacterial poly([R]-3-hydroxybutyrate) (PHB) blocks were synthesized and evaluated as possible constituents in acrylic bone cements for use in orthopaedic applications. The copolymers were produced by conventional free radical copolymerization and incorporated in one commercially available acrylic bone cement brand, Antibiotic Simplex (AKZ). Cements with formulations containing 6.7 and 13.5 wt % of PMMA-graft-PHB were prepared. The morphology of the graft copolymer particles was suggested to influence the ability of the modified cement to be processed. Formulations containing more than about 20 wt % of the graft copolymer resulted in cement doughs that, both after first preparation and several hours later, were either sandy or soft spongy in texture and, thus, would be unacceptable for use in orthopaedic applications. The morphologies of the powders and the volumetric porosity (p) and ultimate ...

2006-04-01

154

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...

2002-07-01

155

Ethanol production and a case study of ethanol produced from sweet sorghum stalks via solid state fermentation  

Energy Technology Data Exchange (ETDEWEB)

Ethanol has excellent fuel properties, such as high octane, high heat of vaporization and low photochemical reactivity in the atmosphere. It is less volatile than gasoline and there is lower smog formation from evaporative emissions of pure ethanol compared to gasoline. As such, ethanol has emerged as an important alternative energy source that is sustainable, efficient, cost effective, convenient and safe. In 2006, global production of ethanol reached 13.5 billion gallons, up from 12.1 billion gallons in 2005. However, in light of the current debate of food versus fuel, the industry must shift to non-food feedstocks. This paper described an emerging technology to cost-effectively produce ethanol from sweet sorghum stalks, the most promising alternative feedstock to corn, via solid state fermentation (SSF). Experiments of advanced solid state fermentation (ASSF) for ethanol production from sweet sorghum by Saccharomyces cerevisiae were conducted in laboratory and ...

2008-07-01

156

Energy and angular distributions of neutrons from 90 MeV proton and 140 MeV alpha-particle bombardment of nuclei  

International Nuclear Information System (INIS)

We measured neutron time-of-flight spectra from 90 MeV protons and 140 MeV alpha particles bombarding thin targets of Al, Ni, Zr, and Bi at laboratory angles between 20_0 and 135_0. The low-energy (5 to 45 MeV) portions of the spectra were measured with 5 cm diameter by 5 cm deep NE-213 counters at 1 m flight paths with n-#betta# pulse-shape discrimination. The high-energy (35 to 150 MeV) portions of the spectra were measured with 12.7 cm diameter by 10.2 cm deep NE-102 counters at flight paths of 2.0 to 5.0 m. The proton-induced measured neutron spectra reveal three distinct energy regions: a low-energy evaporation region, a high-energy region dominated by the quasifree scattering process, and an intermediate-energy region dominated by multistep, preequilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-particle induced neutron spectra show these same distinct energy regions plus an exponential falloff above the ...

157

Effect of hydraulic retention time on the biodegradation of complex phenolic mixture from simulated coal wastewater in hybrid UASB reactors  

International Nuclear Information System (INIS)

This study describes the feasibility of anaerobic treatment of complex phenolics mixture from a simulated synthetic coal wastewater using four identical 13.5 L (effective volume) bench scale hybrid up-flow anaerobic sludge blanket (HUASB) (combining UASB + anaerobic filter) reactors at four different hydraulic retention times (HRT) under mesophilic (27 #+-# 5 "oC) conditions. Synthetic coal wastewater with an average chemical oxygen demand (COD) of 2240 mg/L and phenolics concentration of 752 mg/L was used as substrate. The phenolics contained phenol (490 mg/L); m-, o-, p-cresols (123.0, 58.6, 42 mg/L); 2,4-, 2,5-, 3,4- and 3,5-dimethyl phenols (6.3, 6.3, 4.4 and 21.3 mg/L) as major phenolic compounds. The study demonstrated that at optimum HRT, 24 h, and phenolic loading rate of 0.75 g COD/(m"3-d), the phenolics and COD removal efficiency of the reactors were 96% and 86%, respectively. Bio-kinetic models were applied to data obtained from experimental studies in ...

2008-05-01

158

Carbon dioxide absorption of He--Ne laser radiation at 4. 2. mu. m: characteristics of self and nitrogen broadened cases  

Energy Technology Data Exchange (ETDEWEB)

A laser resonance absorption spectrometer is used to investigate the characteristics of both self and nitrogen collision broadened carbon dioxide in resonance with He--Ne laser radiation at 4.2 ..mu..m. The absorption coefficient in these broadening conditions has contributions from the R(28) to R(34) absorption lines of the ..nu../sub 3/ CO/sub 2/ spectrum. The Fletcher-Powell optimization method is used to reduce the raw absorption data and to find the best value average collision broadening coefficient and laser emission frequency for a Lorentzian line shape model of the contributing lines. Pure carbon dioxide absorption in a pressure range of from 0.0016 atm (1.25 Torr) to 0.33 atm (250 Torr) is described well by the model with an average self broadening coefficient of 0.084 +- 0.008 cm/sup -1/ atm/sup -1/ for laser frequencies located at either 2370.591 +- 0.020 cm/sup -1/ or 2371.135 +- 0.019 cm/sup -1/. Nitrogen broadened carbon dioxide in the total pressure ...

1989-03-01

159

Carbon beam irradiation of human monolayer cells  

Energy Technology Data Exchange (ETDEWEB)

The effect of the heavy particle irradiation on cell survival is different from that of X-ray irradiation. In Japan, heavy particles will be applied to cancer patients in the near future. This study was performed to determine the effect that carbon particle irradiation exerts to human monolayer cells in vitro, in comparison with the effect of 200 kVp X-ray. Two human cell lines, HeLaS3 and RMUG, were used. The irradiation was carried out by the RIKEN ring cyclotron and 200 kVp X-ray. The experimental procedure is explained. Also split dose experiment was carried out by applying equally divided doses at intervals of 2 - 4 hours. The Bragg curve of 135 MeV/n carbon beam through the lucite plates with different thickness is given. Thus the different LETs were obtained. The survival curves for 200 kVp X-ray and the various LETs of carbon beam are shown. The curves became steeper, and Do values decreased with increasing LETs in both cell lines. The relative biological ...

1993-12-31

160

Assessment of generation temperatures of crude oils  

Energy Technology Data Exchange (ETDEWEB)

Biological marker maturity parameters were used to estimate the minimum HC generation temperatures of crude oils from Eastern Hungary. More than 50 oils and oil shows were analysed. Molecular- and homologous-ratios of biological marker compounds (triterpanes, steranes, mono- and triaromatic steroid hydrocarbons) were used as maturation parameters. The oils have at least five maturity stages, i.e. they have been generated under different thermal conditions. The highest reservoir temperature in each group was chosen as the best estimate of the groups' temperature just below the generation temperature, i.e. reservoirs of the group might be expected to be at shallower depths (lower temperatures) than those of the generation zone due to vertical migration into pools. For each maturation level, a threshold temperature range for genesis was inferred from reservoir temperatures; they are from 130-135{sup o}C for the least mature oils to 210-215{sup o}C for the ...

2000-07-01

 
 
 
 
161

A study of the lifetime occurrence of neoplasia and breed differences in a cohort of German Shepherd Dogs and Belgian Malinois military workingn> dogs that died in 1992.  

Science.gov (United States)

The population of U.S. Department of Defense military working dogs provides an opportunity to study the lifetime occurrence of neoplasia in 2 breeds of dogs--the German Shepherd Dog and the Belgian Malinois. Medical records were reviewed for all dogs that died or were euthanized in 1992 (135 German Shepherd Dogs and 106 Belgian Malinois). Histologically confirmed neoplasms were recorded. More than 30% of both breeds (41 German Shepherd Dogs and 33 Belgian Malinois) developed at least 1 primary neoplasm during their lives, with 10% developing more than 1 neoplasm. Nearly 57% of the neoplasms were benign, and approximately 43% were malignant. German Shepherd Dogs lived 9.7 years, on average, and Belgian Malinois lived 7.9 years, on average. Of the dogs that developed any neoplasm, Belgian Malinois had a mean age at 1st diagnosis that was 1.1 years younger and a mean age at 1st diagnosis of malignancy that was 1.7 years younger than those in German Shepherd Dogs. The ...

162

A Human Reliability Analysis of Post- Accident Human Errors in the Low Power and Shutdown PSA of KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS low power and shutdown (LPSD) probabilistic risk assessment (PRA) Standard, evaluated the LPSD PSA model of the KSNP, Yonggwang Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the post-accident human errors in the LPSD PSA model for the KSNP showed that 10 items among 19 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for post-accident human errors in the LPSD PSA model for the KSNP. Following tasks are the improvements in the HRA of post-accident human errors of the LPSD PSA model for the KSNP compared with the previous one: Interviews with operators in the interpretation of the procedure, modeling of operator actions, and the quantification results of human errors, site visit. Applications of limiting value to the combined post-accident human errors. Documentation of ...

2010-05-01

163

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

164

White Rose oilfield development application. CD-ROM ed.  

Energy Technology Data Exchange (ETDEWEB)

Located approximately 350 km east of Newfoundland, on the eastern edge of the Jeanne d'Arc Basin, and approximately 50 km from both the Terra Nova and Hibernia oilfields, the White Rose oilfield is considered the main oil producing basin off the eastern coast of North America. Husky Oil is very active in the region and holds almost 32 per cent net working interest in the Significant Discovery License areas in the Jeanne d'Arc basin. The development of an economically significant oil discovery in the White Rose Significant Discovery Area is being proposed jointly by Husky Oil and Petro-Canada. It is estimated that the project would enable the recovery of an estimated 36 million cubic meters (230 million barrels) of recoverable oil in this area that covers approximately 40 square kilometers. The operators propose to use a ship-shaped floating production, storage and offloading (FPSO) facility which could store up to 135,000 cubic meters (850,000 ...

2001-01-01

165

Trace elements and radioactivity measurements in some terrestrial food crops in Jos-plateau, north central, Nigeria; Elements traces et mesures de la radioactivite dans quelques recoltes vivrieres terrestres du plateau de Jos dans le centre-nord du Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Some crops of important nutritive requirements have been collected from farmlands located in Bitsichi an old tin mining town in north central region of Nigeria. The food crops were analyzed in order to determine trace element concentrations level using Neutron Activation Analysis (NAA). The activity concentrations due to natural radionuclides in the food samples and soil samples collected within the root zone of the crops were also determined using gamma-ray spectrometry (GRS). The NAA results obtained showed higher concentration of Potassium among the essential elements in all the crops. Calcium concentration in both maize and Guinea corn was below detection limit and also Zn in Green beans, sweet potato and cassava. The trace elements; Sc, Hf, Sm, and Th, were below detection limit in all the crops except in Green beans. Rubidium (Rb) and lanthanum (La) were below detection limits only in Cabbage. The activity concentrations of the natural radionuclides in the food samples were found ...

2007-01-15

166

Trace elements and radioactivity measurements in some terrestrial food crops in Jos-plateau, north central, Nigeria  

International Nuclear Information System (INIS)

Some crops of important nutritive requirements have been collected from farmlands located in Bitsichi an old tin mining town in north central region of Nigeria. The food crops were analyzed in order to determine trace element concentrations level using Neutron Activation Analysis (NAA). The activity concentrations due to natural radionuclides in the food samples and soil samples collected within the root zone of the crops were also determined using gamma-ray spectrometry (GRS). The NAA results obtained showed higher concentration of Potassium among the essential elements in all the crops. Calcium concentration in both maize and Guinea corn was below detection limit and also Zn in Green beans, sweet potato and cassava. The trace elements; Sc, Hf, Sm, and Th, were below detection limit in all the crops except in Green beans. Rubidium (Rb) and lanthanum (La) were below detection limits only in Cabbage. The activity concentrations of the natural radionuclides in the food samples were found ...

167

THE DOUBLE-DEGENERATE NUCLEUS OF THE PLANETARY NEBULA TS 01: A CLOSE BINARY EVOLUTION SHOWCASE  

International Nuclear Information System (INIS)

We present a detailed investigation of SBS 1150+599A, a close binary star hosted by the planetary nebula PN G135.9+55.9 (TS 01). The nebula, located in the Galactic halo, is the most oxygen-poor known to date and is the only one known to harbor a double degenerate core. We present XMM-Newton observations of this object, which allowed the detection of the previously invisible component of the binary core, whose existence was inferred so far only from radial velocity (RV) and photometric variations. The parameters of the binary system were deduced from a wealth of information via three independent routes using the spectral energy distribution (from the infrared to X-rays), the light and RV curves, and a detailed model atmosphere fitting of the stellar absorption features of the optical/UV component. We find that the cool component must have a mass of 0.54 #+-# 0.2 M_s_u_n, an average effective temperature, T_e_f_f, of 58,000 #+-# 3000 K, a mean radius of 0.43 #+-# ...

2010-05-01

168

THE CHEMICAL EVOLUTION OF THE URSA MINOR DWARF SPHEROIDAL GALAXY  

International Nuclear Information System (INIS)

We present an abundance analysis based on high-resolution spectra of 10 stars selected to span the full range in metallicity in the Ursa Minor (UMi) dwarf spheroidal (dSph) galaxy. We find that [Fe/H] for the sample stars ranges from -1.35 to -3.10 dex. Combining our sample with previously published work for a total of 16 luminous UMi giants, we establish the trends of abundance ratios [X/Fe] as functions of [Fe/H] for 15 elements. In key cases, particularly for the #alpha#-elements, these trends resemble those for stars in the outer part of the Galactic halo, especially at the lowest metallicities probed. The neutron-capture elements show an r-process distribution over the full range of Fe metallicity reached in this dSph galaxy. This suggests that the duration of star formation in the UMi dSph was shorter than in other dSph galaxies. The derived ages for a larger sample of UMi stars with more uncertain metallicities also suggest a population dominated by ...

2010-08-10

169

Oil turbulence in the next decade. An essay on high oil prices in a supply-constrained world  

International Nuclear Information System (INIS)

A CIEP analysis of the recent development of demand and supply for crude oil indicates that the mismatch in supply and demand growth could cause tighter oil markets than we already experience today. In the World Energy Outlook 2007, the International Energy Agency (IEA) warned of a possible 'energy crunch'. But what was anticipated to happen in the first part of the next decade has been fast-forwarded to today, more than 5 years earlier, and could shake the very foundation of our energy systems if no action is undertaken. Without exaggeration, the recent developments in the international oil market are ground-breaking: a little over a year ago, in January 2007, the West Texas Intermediate crude oil price (WTI) traded for USD50 dollar a barrel. Within a year, the price doubled to USD100 per barrel in January 2008 and pushed through to over USD135 in June 2008, against the backdrop of the fresh market supposition about reaching a whopping USD200 per barrel in 2009. ...

170

Evaluation of small-bowel transit for solid and liquid test meal in healthy men and women  

International Nuclear Information System (INIS)

Evaluation of severe functional gastrointestinal motility disorders requires an investigation of the entire gastrointestinal tract. This should be possible with a single radionuclide imaging study. The purpose of this study was (1) to define normal values of small-bowel transit in men and women and (2) to assess a possible difference between gender or test meal, since it has been shown that women have slower gastric emptying than men, and gastric emptying of solids is slower than liquids. A standard gastric-emptying test for a solid (technetium-99m sulphur colloids, 230 Kcal) and liquid (indium-111 DTPA water) test meal was performed in 12 healthy male and 12 healthy female volunteers. After 135 min, the volunteer was place in the supine position for static imaging of the abdomen every 15 min for 6 h. Decay and crossover-corrected geometric mean gastric-emptying data were fit to a modified power exponential function to determine the 10% stomach emptying time for ...

1999-12-01

171

CO2 Capture by Absorption with Potassium Carbonate  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO3 promoted by piperazine (PZ). Pilot plant testing was performed in a 16.8-inch ID absorber and stripper with recirculation of air and CO{sub 2}. Three solvents (7 m MEA, 5 m K{sup +}/2.5 m PZ, and 6.4 m K{sup +}/1.6 m PZ) were tested in four campaigns with three different absorber packings. Pilot plant testing established that 5 m K{sup +}/2.5 m PZ requires two times less packing than 7 m MEA and three times less packing than 6.4 m K{sup +}/1.6 m PZ. A rigorous model of the thermodynamics and mass transfer was developed in the RateSep{trademark} block of AspenPlus{reg_sign}. The double matrix stripper reduces energy consumption by 5 to 15%. The best K{sup +}/PZ solvent, 4 m K{sup +}/4 m PZ, and the best process configuration, double matrix stripper with a double intercooled absorber, requires equivalent work of 40 ...

2007-08-31

172

All aboard: Terra Nova 'not for the faint hearted'  

Energy Technology Data Exchange (ETDEWEB)

The state of exploration in the Terra Nova field offshore Newfoundland, and the progress in constructing the floating production, storage and offloading (FPSO) at Bull Arm, the assembly site west of St. John's for the Terra Nova vessel, are described. Comparisons are made between the excitement created by the first production well at Leduc in Western Canada in 1947, and the offshore developments currently underway and accelerating offshore Newfoundland. It is estimated that exploration and development offshore had barely touched the surface, with only 160 wells of all types drilled to date, of which 48 exploration wells have uncovered 1.7 billion barrels of oil. The area is practically unexplored; the source rock is there, and the current estimate is that there are a number of basins in the offshore area that are several times the size of the Jeanne d'Arc Basin, where the Hibernia field is currently producing about 135,000 barrels of oil per day. ...

2001-08-06

173

The ternary system cerium-palladium-silicon  

International Nuclear Information System (INIS)

Phase relations in the ternary system Ce-Pd-Si have been established for the isothermal section at 800 deg. C based on X-ray powder diffraction and EMPA techniques on about 130 alloys, which were prepared by arc-melting under argon or powder reaction sintering. Eighteen ternary compounds have been observed to participate in the phase equilibria at 800 deg. C. Atom order was determined by direct methods from X-ray single-crystal counter data for the crystal structures of #tau#_8-Ce_3Pd_4Si_4 (U_3Ni_4Si_4-type, Immm; a=0.41618(1), b=0.42640(1), c=2.45744(7) nm), #tau#_1_6-Ce_2Pd_1_4Si (own structure type, P4/nmm; a=0.88832(2), c=0.69600(2) nm) and also for #tau#_1_8-CePd_1_-_xSi_x (x=0.07; FeB-type, Pnma; a=0.74422(5), b=0.45548(3), c=0.58569(4) nm). Rietveld refinements established the atom arrangement in the structures of #tau#_5-Ce_3PdSi_3 (Ba_3Al_2Ge_2-type, Immm; a=0.41207(1), b=0.43026(1), c=1.84069(4) nm) and #tau#_1_3-Ce_3_-_xPd_2_0_+_xSi_6 (0#<=#x#<=#1, Co_2_0Al_3B_6-type, ...

2009-09-01

174

Potential of sub-ablative pulsed CO{sub 2} laser irradiation on inhibition of artificial caries-like lesion progress in bovine dental enamel; Potencial de inibicao da progressao da carie artificial por irradiacao sub-ablativa com laser de CO{sub 2} pulsado em esmalte dental bovino  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the ...

2005-07-01

175

Implementation of renewable technologies - Opportunities and barriers. Zimbabwe country study  

Energy Technology Data Exchange (ETDEWEB)

Renewable Energy Technologies (RETS) have over the years become an integral part of the energy supply chain in most developed countries. Recent projections show that 13.5% of the world's primary energy supply comes from renewable and this figure has an aggregated annual growth rate of 16%. Wind has the highest annual growth rate of 22% while the least annual growth rate of 2% is for hydropower. The main push for renewable like wind in the OECD countries are environmental concerns and the business aspect in power generation. The situation is however completely different in Africa, where the thrust for RETs is developmental based. Although the continent has abundant renewable energy resources like solar, biomass, wind and hydro potential, they have remained largely unexploited. Several efforts have been made to help African countries like Zimbabwe to exploit such resources. The main objectives of this country study included review of Zimbabwe's ...

2001-07-01

176

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full phase function versus using approximations of ...

2009-05-26

177

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 cells were assessed for clonogenic survival after being plated at ...

1996-09-01

178

The ternary system cerium-palladium-silicon  

Science.gov (United States)

Phase relations in the ternary system Ce-Pd-Si have been established for the isothermal section at 800 deg. C based on X-ray powder diffraction and EMPA techniques on about 130 alloys, which were prepared by arc-melting under argon or powder reaction sintering. Eighteen ternary compounds have been observed to participate in the phase equilibria at 800 deg. C. Atom order was determined by direct methods from X-ray single-crystal counter data for the crystal structures of tau{sub 8}-Ce{sub 3}Pd{sub 4}Si{sub 4} (U{sub 3}Ni{sub 4}Si{sub 4}-type, Immm; a=0.41618(1), b=0.42640(1), c=2.45744(7) nm), tau{sub 16}-Ce{sub 2}Pd{sub 14}Si (own structure type, P4/nmm; a=0.88832(2), c=0.69600(2) nm) and also for tau{sub 18}-CePd{sub 1-x}Si{sub x} (x=0.07; FeB-type, Pnma; a=0.74422(5), b=0.45548(3), c=0.58569(4) nm). Rietveld refinements established the atom arrangement in the structures of tau{sub 5}-Ce{sub 3}PdSi{sub 3} (Ba{sub 3}Al{sub 2}Ge{sub 2}-type, Immm; a=0.41207(1), b=0.43026(1), ...

2009-09-15