WorldWideScience
 
 
1

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the ...

2

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low ...

1989-01-01

3

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

4

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

5

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

6

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to ...

2000-01-01

7

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

8

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

9

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

10

This certifies that the face of Flat Granny ... - Face in Space - NASA  

Science.gov (United States)

This certifies that the face of Flat Granny has flown in space aboard the Space Shuttle Discovery on mission STS-. 133 from February 24 - March 9, 2011. ...

12

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...

1996-12-31

13

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

14

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

15

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

16

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

17

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

18

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

19

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

20

PROBABILISTIC SYSTEMS MODELING AND COST/PERFORMANCE METHODOLOGIES ...  

Science.gov (United States)

sidered as produced in one period of time for learning curve purposes. A ...... 61 FORMAT (6X,13,3XTARGET DATE 1,13,1X,A6,' NO LATER THAN',F4.0, ...

 
 
 
 
21

Cytogenetic analysis of three sea catfish species (Teleostei, Siluriformes, Ariidae) with the first report of Ag-NOR in this fish family  

UK PubMed Central (United Kingdom)

Despite their ecological and economical importance, fishes of the family Ariidae are still genetically and cytogenetically poorly studied. Among the 133 known species of ariids, only eight have been...Full Text Available

2010-04-01

22

CD133 Positive Embryonal Rhabdomyosarcoma Stem-Like Cell Population Is Enriched in Rhabdospheres  

UK PubMed Central (United Kingdom)

Cancer stem cells (CSCs) have been identified in a number of solid tumors, but not yet in rhabdomyosarcoma (RMS), the most frequently occurring soft tissue tumor in childhood. Hence, the aim of this...Full Text Available

23

BUBL LINK: Computer programming - visual basic  

Wastenet

...BUBL LINK: Computer programming - visual basic BUBL LINK Catalogue of Internet Resources Home | Search | Subject Menus | Countries ...O | P | Q | R | S | T | U | V | W | X | Y | Z Computer programming - visual basic Titles ... Author: Microsoft Subjects: computer programming - visual basic DeweyClass: 005.133 Resource type: software SearchVB....com Subjects: computer programming - visual basic DeweyClass: 005.133 Resource type: index VB Helper Tutorials ...

24

Comparisons of graphite and spinel Li1.33Ti1.67O4 as anode materials for rechargeable lithium-ion batteries  

International Nuclear Information System (INIS)

The aim of this work was to compare the electrochemical behaviors and safety performance of graphite and the lithium titanate spinel Li1.33Ti1.67O4 with half-cells versus Li metal. Their electrochemical properties in 1 M LiPF6/EC + DEC (1:1 w/w) or 1 M LiPF6/PC + DEC (1:1 w/w) at room and elevated temperatures (30 and 60 deg C) have been studied using galvanostatic cycling. At 30 deg C graphite has higher reversible capacity than Li1.33Ti1.67O4 when using the LiPF6/EC + DEC as electrolyte. At 60 deg C graphite declines in cell capacity yet Li1.33Ti1.67O4 remains almost unchanged. In a propylene carbonate (PC) containing electrolyte, graphite electrode exfoliates and loses its mechanical integrity while Li1.33Ti1.67O4 electrode is very stable. An accelerating rate calorimeter (ARC) and microcalorimeter have been used to compare the thermal stability of lithiated lithium titanate spinel and graphite. ...

2005-07-25

25

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

26

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

27

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

28

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

29

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

30

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...

31

Atomic masses of "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs  

International Nuclear Information System (INIS)

The atomic masses of the alkali-metal isotopes "6Li,"2"3Na,"3"9","4"1K,"8"5","8"7Rb, and "1"3"3Cs have been obtained from measurements of cyclotron frequency ratios of pairs of ions simultaneously trapped in a Penning trap. The results, with one standard deviation uncertainty, are: M("6Li)=6.015 122 887 4(16)u,M("2"3Na)=22.989769 282 8(26)u,M("3"9K)=38.963 706 485 6(52)u,M("4"1K)=40.961 825 257 4(48)u,M("8"5Rb)=84.911 789739(9)u,M("8"7Rb)=86.909 180 535(10)u, and M("1"3"3Cs)=132.905 451 963(13)u. Our mass of "6Li yields an improved neutron separation energy for "7Li of 7251.1014(45) keV.

2010-10-01

32

Fragranced consumer products: Chemicals emitted, ingredients unlisted  

British Library Electronic Table of Contents (United Kingdom)

Fragranced consumer products are pervasive in society. Relatively little is known about the composition of these products, due to lack of prior study, complexity of formulations, and limitations and protections on ingredient disclosure in the U.S. We investigated volatile organic compounds (VOCs) emitted from 25 common fragranced consumer products-laundry products, personal care products, cleaning supplies, and air fresheners-using headspace analysis with gas chromatography/mass spectrometry (GC/MS). Our analysis found 133 different VOCs emitted from the 25 products, with an average of 17 VOCs per product. Of these 133 VOCs, 24 are classified as toxic or hazardous under U.S. federal laws, and each product emitted at least one of these compounds. For ''green'' products, emissions of these c...

2011-01-01

33

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

34

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

35

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

36

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

37

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

38

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

39

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

40

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

 
 
 
 
41

ap11137i.b  

Science.gov (United States)

NaiaJ MajaL 8"3 LalaM KamaN JanaP 1# JaoaQ "# !" ##02 IaqaR ';?9#.%) 1"30 HaraS !"*!'$ 12#0!"# GasaT 23 1 FataU "# 1 EauaW 1"3 DavaX CawaX 133 ! ...

42

Improved Mobilization of the CD34+ and CD133+ Bone Marrow-Derived Circulating Progenitor Cells by Freshly Isolated Intracoronary Bone Marrow Cell Transplantation in Patients with Ischemic Heart Disease  

UK PubMed Central (United Kingdom)

Cell therapy is a promising novel option for treatment of cardiovascular disease. Because the role of bone marrow-derived circulating progenitor cells (BM-CPCs) after cell therapy is less clear, we...Full Text Available

2011-09-01

43

FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color display tracks the ...

44

Caesium clocks. Status and research activities  

International Nuclear Information System (INIS)

Thirty years ago, in 1967, the new definition of the second based on a quantum phenomenon, the hyperfine splitting of the groundstate of the "1"3"3Cs atom, was passed by the 13th General Conference on Weight and Measure. What followed was a fascinating improvement of the performance of caesium clocks which is still pursued. Their total uncertainty could be reduced, until 1995, by 4 orders of magnitude. With the development of the so-called fountain clocks, another factor of ten is within reach. (orig.)

1998-02-01

45

Anisotropic many-body effects in the quasiparticle velocity of Nb  

International Nuclear Information System (INIS)

Fermi radii and velocities are determined by deconvoluting de Haas-van Alphen data. Comparison of these data with accurate augmented-plane-wave band-structure results establishes the reliability of the augmented-plane-wave calculations and allows a determination of the anisotropic many-body enhancement factor lambda(k). The Fermi-surface average of 1.33 suggests a large electron-electron contribution. Our anisotropic lambda(k) porvides a detailed test and guide for model calculations of many-body enhancement.

46

2006d.rms - NASA  

Science.gov (United States)

... $84JAN07X 133 147.654 ps 56 fs/s RMS_DEL: $95NOV21DX 607 144.552 ps 208 ...... $86MAR09XI 378 34.285 ps 77 fs/s RMS_DEL: $95MAR23XA 1628 34.270 ps 223 ...

47

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

48

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

49

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

50

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

51

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

52

Percutaneous Treatment of Malignant Jaundice Due to Extrahepatic Cholangiocarcinoma: Covered Viabil Stent Versus Uncovered Wallstents  

International Nuclear Information System (INIS)

To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median survival was 180.5 days for the Wallstent and 243.5 days for the Viabil group (P = 0.039). Complications and mean cost were ...

2010-02-01

53

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

54

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

55

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

56

Physical characteristics and solubility of long-lived airborne particulates in uranium producing and manufacturing facilities: A report upon completion of the extension to Phase I of the study. Research report No. INFO-0363-1  

Energy Technology Data Exchange (ETDEWEB)

Study of the rate of dissolution in simulated lung fluid of uranium from 3 different ore matrices and from refined uranium dioxide in an essentially all teflon extraction apparatus; the rate of dissolution of thorium from a nickel metal/2 percent thoria mixture; the effect of neutron irradiation of the studied materials upon the dissolution rates; and the adsorptions of the radioisotope tracers barium 133 (substitute for radium), lead 203 and thorium 234 upon the extraction system components.

1989-01-01

57

Computer science handbook. Vol. 13.3. Environmental computer science. Computer science methods for environmental protection and environmental research  

International Nuclear Information System (INIS)

Environmental computer science is a new partial discipline of applied computer science, which makes use of methods and techniques of information processing in environmental protection. Thanks to the inter-disciplinary nature of environmental problems, computer science acts as a mediator between numerous disciplines and institutions in this sector. The handbook reflects the broad spectrum of state-of-the art environmental computer science. The following important subjects are dealt with: Environmental databases and information systems, environmental monitoring, modelling and simulation, visualization of environmental data and knowledge-based systems in the environmental sector. (orig.).

58

An optical fiber methane sensing system employing a two-step reference measuring method  

British Library Electronic Table of Contents (United Kingdom)

An optical fiber methane sensing system utilizing a super-luminescent diode (SLD) in the 1.33-mm band and a fiber Fabry-Perot tunable filter (FFP-TF) is developed. A two-step reference measuring method, which is based on differential absorption technique, is employed; a reference channel is introduced to eliminate the fluctuation of the illuminant spectrum, and the reference wavelength acquired by tuning the FFP-TF is introduced to eliminate the environmental influence. The two-step reference measuring method has improved the reliability and stability of the system. A minimum detectable methane concentration of 0.3% has been experimentally achieved.

2008-01-01

59

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

60

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

 
 
 
 
61

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

62

The effect of heat treatment on the electrochemical corrosion behavior of reactive plasma-sprayed TiN coatings  

British Library Electronic Table of Contents (United Kingdom)

The effect of heat treatment on the corrosion behavior of reactive plasma sprayed TiN coatings in simulated seawater was investigated by electrochemical methods such as the corrosion potential-time curve (Ecorr-t), potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and SEM, etc. The results showed that the corrosion potential of TiN coatings increased after heat treatment; the corrosion current of the TiN coatings after heat treatment (be hereafter referred to as HT-TiN) was 13.3% of the untreated coatings (be hereafter referred to as UT-TiN), and the polarization resistance of HT-TiN was 20 times of UT-TiN, which indicated that the heat treatment had significantly increased the corrosion resistance of the coatings. The corrosion behavior of the coatings was mainly ...

2011-01-01

63

Radiation imposed limits on superconducting magnets: A data base for copper stabilizers  

Energy Technology Data Exchange (ETDEWEB)

Two of eight differently prepared copper stabilizer samples, previously irradiated in the RTNS-II at LLNL, the IPNS-1 and the BSR at ORNL, have been irradiated to a fluence of 1.33 /times/ 10/sup 22/ n/m/sup 2/ at RTNS-II. During the course of the irradiation the samples were periodically removed (without warming) for measurements of the transverse magnetoresistance and returned for continued irradiation. This experiment extends the range of neutron-irradiation-induced resistivity by a factor of five over the previous experiments. A simple model is developed which reproduces the magnetoresistance results of all the experiments to an accuracy of 2.5%. 13 refs., 6 figs.

1987-10-28

64

Oxygen reduction reaction on electrodeposited zinc oxide electrodes in KCl solution at 70 deg. C  

Energy Technology Data Exchange (ETDEWEB)

The reduction of oxygen was studied in 0.1 M KCl at 70 deg. C using the rotating disk electrode (RDE) technique on platinum and electrodeposited ZnO thin film electrodes deposited on platinum substrates. In the absence of Zn{sup 2+} ions in solution, a Tafel slope of 139 mV dec{sup -1} was obtained, a value close to that measured on bare platinum electrode (133 mV dec{sup -1}) and ascribed to the limitation of the reaction rate by the first electron transfer. The main difference between the noble metal and the oxide electrode was a shift of the curves towards more negative potentials. In the presence of Zn{sup 2+} ions, the current density decreased significantly and the Tafel slope was measured at 282 mV dec{sup -1} showing that the electrode was partially blocked by zinc oxide formation reaction intermediates.

2006-04-01

65

Observation of strain-enhanced electron-spin polarization in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron-spin polarization in excess of 70% has been observed in photoemission from a 0.1-#mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x#approx#0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single-band transition.

66

Interaction of constituents of the Yb-Pd-Si system in the range of zero to 40 at.% Yb  

International Nuclear Information System (INIS)

Interaction of Yb-Pd-Si system components is studied, isothermal cross section of this system state diagram at 870 K is constructed. Five new ternary silicides are detected in the system: YbPd_5Si_3, Yb_3Pd_2_0Si_6, YbPd_2Si, YbPd_0_,_6_7Si_1_,_3_3, YbPdSi; the existence of one more -YbPd_2Si_2, earlier known, is confirmed. Crystal structure for all the compounds detected is determined and examined. Data on the materials magnetic properties are obtained. It is assumed that YbPd_2Si, YbPd_2Si_2 and YbPdSi compounds appear to be the Condo-systems. 10 refs., 3 figs., 3 tabs.

67

Industrial hazardous wastes in Finland - trends related to the waste prevention goal  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study was to analyse one of the goals of the latest National Waste Plan of Finland: the relative reduction of hazardous waste (HW) generation by 15% over the period 1992 to 2005.Official statistics and a national database of the annual reports of HW generators were used as one basis for this study. A case study was focused on a selection of HW classes that were considered to be typical to the metal workshop industry. These HW classes were combined to form functional HW groups for the purpose of forming time series. Trends at the company level were studied by performing interviews and by studying the environmental permit documents of about 50 companies.The total amount of HW reported in Finland increased by 133% over the studied period. Meanwhile the GDP of Finland gre...

2008-01-01

68

Electricity demand for South Korean residential sector  

Energy Technology Data Exchange (ETDEWEB)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment.

2009-12-15

69

Electricity demand for South Korean residential sector  

Energy Technology Data Exchange (ETDEWEB)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement the market based pricing policies with non-market policies such as minimum energy efficiency standards and public enlightenment. (author)

2009-12-15

70

Electricity demand for South Korean residential sector  

British Library Electronic Table of Contents (United Kingdom)

This study estimates the electricity demand function for the residential sector of South Korea with the aim of examining the effects of improved energy efficiency, structural factors and household lifestyles on electricity consumption. In the study, time series data for the period from 1973 to 2007 is used in a structural time series model to estimate the long-term price and income elasticities and annual growth of underlying energy demand trend (UEDT) at the end of the estimation period. The result shows a long-term income elasticity of 1.33 and a long-term price elasticity of -0.27% with -0.93% as the percentage growth of UEDT at the end of the estimation period. This result suggests that, in order to encourage energy efficiency in the residential sector, the government should complement...

2009-01-01

71

A new method in the management of skin neoplasm using a flexible radioactive patch  

Energy Technology Data Exchange (ETDEWEB)

We have developed a flexible radioactive polyurethane patch incorporating {beta}-emitting radionuclide (166Ho) to treat malignant skin lesions. We covered the tumor surface (n=133) with the radioactive patch for 33.58 {+-} 5.33 minutes. Radiation dose delivered was 35 Gy for Bowen's disease (n=78), Kaposi sarcoma (n=25), actinic keratosis (n=5), and 50 Gy for BCC (n=17) and squamous carcinoma (n=8). Complete response was observed in 91.7% after the first therapeutic trial, 96.2% after 2nd and 97.7% after 4th trial with excellent cosmetic outcome for 31.15{+-}13.88 months of follow-up. Radioactive patch therapy is effective for superficial skin cancers that are impractical for surgery.

2005-07-01

72

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

73

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

74

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

75

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

76

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

77

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

78

The neurological mouse mutations jittery and hesitant are allelic and map to the region of mouse chromosome 10 homologous to 19p13.3  

Energy Technology Data Exchange (ETDEWEB)

Jittery (ji) is a recessive mouse mutation on Chromosome 10 characterized by progressive ataxic gait, dystonic movements, spontaneus seizures, and death by dehydration/starvation before fertility. Recently, a viable neurological recessive mutation, hesitant, was discovered. It is characterized by hesitant, uncoordinated movements, exaggerated stepping of the hind limbs, and reduced fertility in males. In a complementation test and by genetic mapping we have shown here that hesitant and jittery are allelic. Using several large intersubspecific backcrosses and intercrosses we have genetically mapped ji near the marker Amh and microsatellite markers D10Mit7, D10Mit21, and D10Mit23. The linked region of mouse Chromosome 10 is homologous to human 19p13.3, to which several human ataxia loci have recently been mapped. By excluding genes that map to human 21q22.3 (Pfkl) and 12q23 (Nfyb), we conclude that jittery is not likely to be a genetic mouse model for human ...

1996-08-01

79

Station blackout induced severe accident analysis for Daya Bay NPP  

International Nuclear Information System (INIS)

In Aug 2002, the National Nuclear Safety Administration of China issued the policy statement for building new nuclear power plants, which requires the probability based safety goal of severe core damage must be lower than 10"-"5/a. The station blackout accident would be possible to cause a severe accident if there were no effective engineering measures to prevent or mitigate the consequences of the accident. By using MELCOR1.8.5 and KORIGEN codes, the present paper has simulated the station blackout accident for Daya Bay Nuclear Power Plant and calculated the source term and radioactivity of main fission products in the containment in the late phase of the accident. CsI is found the main part of aerosol in the containment. The Xe133 and Xe133m start releasing from the containment after its failure, and the upper limit of the amount of released radioactivity is evaluated less than 5.5 x 10"1"5Bq. The total radioactivity of other significant ...

2004-10-04

80

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic ...

1998-12-31

 
 
 
 
81

Isothermal heat measurements of TBP-nitric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased systems. Rate expressions were derived and rate constants ...

1994-12-16

82

Binding Affinity of Re(CO)_3 Cl(EPBI) for A#beta#_(_1_#approx#_4_0_) Aggregates and Evaluation of ["9"9Tc"m(CO)_3]"+-EPBI  

International Nuclear Information System (INIS)

The aim of this paper was to develop potential technetium 99m-labeled diagnostic imaging agents specific for the detection of A#beta# plaques. Based on previously obtained A#beta# plaque-specific biphenyls containing a benzimidazol group, "9"9Tc"m and Re-benzimidazol derivatives, ["9"9Tc"m(CO)_3]"+-EPBI and Re(CO)_3 Cl (EPBI), were prepared. The latter showed binding affinities towards A#beta#_(_1_#approx#_4_0_) aggregates in vitro (K_d=13.3 #mu#mol/L) by fluorophotometry. 2-(1-Ethylbenzimidazol-2-yl) pyridine (EPBI) and Re(CO)_3 Cl (EPBI) were synthesized. Binding affinity of Re(CO)_3 Cl (EPBI) for A#beta#_(_1_#approx#__4_0_) aggregates was determined. ["9"9Tc"m(CO)_3]"+-EPBI was prepared and analyzed by HPLC and paper eletrophoresis. Its biodistribution in mice was obtained. The K_d value of Re (CO)_3 Cl (EPBI) is 13.3 #mu#mol/L. Biodistribution of ["9"9Tc"m(CO)_3]"+-EPBI in mice shows brain penetration (0.63 #+-# 0.17) %ID/g (n=3) at 2 min ...

2009-11-01

83

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

84

[Natural course of asymptomatic gallstone disease].  

Science.gov (United States)

Of 1850 patients with cholelithiasis diagnosed in the past 17 years, 1116 female and 734 male, 598 patients (32.3%) presented with one or more of three major symptoms, i.e., abdominal pain, fever and jaundice, whereas the remainder (67.7%) had none of these symptoms. The proportion of the asymptomatic patients was similar in all age groups, being around 70%. Only 20 per cent of 680 asymptomatic patients, followed for 10 to 17 years (median 13.3 years), developed biliary symptoms. Older patients over 70 years of age had a higher rate of change to the symptomatic group, as compared with younger patients under 70, 29.5% vs. 19.3%, respectively. During this period, carcinoma of the gallbladder developed in one of the asymptomatic patients (0.1%). Oral dissolution therapy was successful in only 4.2 per cent of attempted cases and associated with a recurrence rate of as high as 20%. We conclude that asymptomatic gallstone patients should only be followed up by ultrasound ...

1993-07-01

85

The cometary activity of Centaur P/2004 A1 (LONEOS)  

British Library Electronic Table of Contents (United Kingdom)

Abstract P/2004 A1 (LONEOS) is one of the few active objects in the dynamical class of Centaurs. It has been recently injected into an inner orbit with a perihelion distance-q-= 5.5 au. The aim of this paper is to characterize the dust coma of this peculiar object, 2.5 yr after its first -new- perihelion passage inside the Solar system. Broad-band visible images taken at the TNG telescope in 2007 February were analysed in order to characterize the dust coma of the Centaur: it was still quite active at-rh-= 6.5 au post-perihelion, with a coma and a well-developed wide tail-like structure, with a measured-R-Af= 162 10-cm in an aperture radius = 104 km. The (V---R) colour and the reddening values depict a scenario of a slightly red dust coma. A dust mass-loss rate of--= 133 kg-s-1 is derived ...

2011-01-01

86

The CO{sub 2} gasification kinetics of olive residue  

Energy Technology Data Exchange (ETDEWEB)

Orujillo, sometimes called wood matter from pressed oil-stone (WPOS) is a residue from the olive oil mill industry. The generation of this biomass residue is concentrated in small areas allowing its use as fuel for medium size gasification and combustion plants. Rates of gasification of WPOS char were measured in a TGA at various temperatures (800-850-875-900-950{sup o}C), CO{sub 2} partial pressures (0.20-0.35-0.50 bar) and CO partial pressures (0.0-0.20 bar). The experiments were carried out with a monolayer bed of very fine particles well exposed to the gas so as to minimise mass and heat transfer resistances. Two kinetic models, the nth order model and Langmuir-Hinshelwood model, have been used to fit with the reactivity data. For pure CO{sub 2} experiments the kinetic parameters of nth order model were E=133 kJ/mol and n=0.43. The Langmuir-Hinshelwood kinetic model clearly describes the observed CO inhibition effect on the CO{sub 2} gasification.(author)

2003-02-01

87

Structure of the triplet of low-lying states in sup 101 Mo  

Energy Technology Data Exchange (ETDEWEB)

The properties of the triplet of low-lying states in {sup 101}Mo have been studied through spectroscopy of the {gamma} radation following thermal neutron capture in {sup 100}Mo and {beta}-decay of {sup 101}Nb and through a measurement of the proton angular distributions in the {sup 100}Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2{sup +} state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2{sup +} for the 13.5 keV level. The E2 components in the 13.5 (3/2{sup +}->1/2{sup +}) and 43.5 keV (5/2{sup +}->3/2{sup +}) transitions are {le} 8x10{sup -4} and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into consideration the transitional character of the {sup 100}Mo boson core, account for the ...

1991-06-01

88

Structure of the triplet of low-lying states in "1"0"1Mo  

International Nuclear Information System (INIS)

The properties of the triplet of low-lying states in "1"0"1Mo have been studied through spectroscopy of the #gamma# radation following thermal neutron capture in "1"0"0Mo and #beta#-decay of "1"0"1Nb and through a measurement of the proton angular distributions in the "1"0"0Mo(d, p) reaction with 14 MeV deuteron energy. The half-lives of the 13.5 keV state and the 57.0 keV 5/2"+ state have been measured as 226(7) and 133(7) ns, respectively. These values and the quadrupole/dipole mixing ratios of the 13.5 keV and 43.5 keV transitions yield spin and parity 3/2"+ for the 13.5 keV level. The E2 components in the 13.5 (3/2"+#->#1/2"+) and 43.5 keV (5/2"+#->#3/2"+) transitions are #<=# 8x10"-"4 and 54(9)%, respectively. The possibility of an additional state near to the 57.0 keV level is discussed. IBFM/PTQM calculations, taking into consideration the transitional character of the "1"0"0Mo boson core, account for the electromagnetic-transition and ...

89

Strain enhanced electron spin polarization observed in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements represent the first observation of strain-enhanced electron spin polarization for ...

1991-05-06

90

Prevalence of hepatosplenomegaly in beta thalassemia minor subjects in Iran  

Energy Technology Data Exchange (ETDEWEB)

Introduction: Thalassemia is the most common hereditary blood disorder in the world. Iran is located on the thalassemic belt and there is a high prevalence of the hepatosplenomegaly in beta thalassemia minor patients which is reported to be very variable. The goal of this research was to study the frequency of these signs in the cases with beta thalassemia minor patients in Iran. Materials and methods: Two hundred and fifty-nine cases that referred to center for pre-marriage tests were divided into two groups according to their MCV, MCH, and HbA2 (beta thalassemia minor cases and control groups). Liver and spleen sizes were determined by ultrasonographic method and the two groups were compared with each other. Results: Average spleen volumes in case and control groups were 163.48 {+-} 133.97 and 126.29 {+-} 53.98 mm{sup 3}, respectively. Average spleen lengths in case and control groups were 10.71 {+-} 1.52 and 10.60 {+-} 5.4 cm, respectively. Conclusion: In the ...

2009-01-15

91

Polyphenol rich botanicals used as food supplements interfere with EphA2-ephrinA1 system  

British Library Electronic Table of Contents (United Kingdom)

The Eph tyrosine kinase receptors and their ephrin ligands play a central role in several human cancers and their deregulated expression or function promotes tumorigenesis, inducing aggressive tumor phenotypes. Green tea extracts (GTE) have been recently found to inhibit Eph-kinase phosphorylation. In order to evaluate the potential contribution of edible and medicinal plants on EphA2-ephrinA1 modulation, 133 commercially available plant extracts used as food supplements, essential and fixed oils were screened with an ELISA-based binding assay. Nine plant extracts, rich of polyphenols, reversibly inhibited binding in a dose-dependent manner (IC"5"0 0.83-24@mg/ml). Functional studies on PC3 prostate adenocarcinoma cells revealed that active extracts antagonized ephrinA1-Fc-induced EphA2-pho...

2011-01-01

92

Phase diagram of the ternary system lauric acid-capric acid-naphthalene  

Energy Technology Data Exchange (ETDEWEB)

The mixture of lauric acid and capric acid is a potential latent heat storage material. However, its eutectic melting temperature is quite high for low-temperature thermal energy storage. Addition of naphthalene is proposed. The ternary system lauric acid-capric acid-naphthalene has been investigated by differential scanning calorimetry (DSC), visual polythermal and chromatography of gases. The phase diagram is of an incongruent eutectic type. The eutectic mixture contains 18.4mol% lauric acid, 63.1mol% capric acid and 18.5mol% naphthalene and melts at 13.3{sup o}C. The peritectic mixture contains 32.4mol% lauric acid, 48.2mol% capric acid and 19.4mol% naphthalene and peritectic temperature of 16.2{sup o}C. The incongruent compound was analysed to be CH{sub 3}(CH{sub 2}){sub 10}COOH.CH{sub 3}(CH{sub 2}){sub 8}COOH. The melting temperature of the lauric acid-capric acid-naphthalene eutectic mixture makes it suitable for cooling applications.

2004-12-15

93

Optical Discs for Storage and Access in ARL Libraries. SPEC KIT 133.  

Science.gov (United States)

This SPEC (Systems and Procedures Exchange Center) kit provides a sample of excerpts from technical and planning documents contributed by 40 Association of Research Libraries (ARL) member libraries that are planning to install or have already implemented optical disc technology. Selected to represent a variety of media and applications, the excerpts address general as well as technical issues. Comments received in telephone interviews with contributors, as well as with other ARL members whose endeavors are not represented in this kit, are incorporated in a concise summary which discusses the overlapping and interrelated concerns of technical considerations, management issues, and impact on user services. In addition, the following original documents are included: (1) a descriptive list of optical disc technology terms from the National Library of Canada; (2) planning documents from the libraries of the Massachusetts Institute of Technology and the Smithsonian Institution; (3) ...

1987-04-01

94

Local control and sequelae following irradiation of Ewing's sarcoma  

International Nuclear Information System (INIS)

135 patients with histologically proven Ewing's sarcoma, treated at the Institute Gustave Roussy between 1960-1974 were reviewed in order to establish the effectiveness and the complications associated with radiotherapy. In 133 patients, a dose of at least 60 Gy for long bones, 55 Gy for flat bones and 45 Gy for vertebrae was given. 26 major complications (of which more than one occured in certain patients) were observed: 12 cases of growth retardation, loss of joint function in 7 cases, 3 fractures, 2 osteonecroses, 2 cases of delayed healing, one massive soft tissue fibrosis, 1 abdominocutaneous fistula, 2 cases of symptomatic pulmonary fibrosis with associated infection, 2 cases of radiation enteropathy, 2 of mammary hypoplasia and 1 osteosarcoma developing in an irradiated zone. These complications necessitated 12 surgical interventions, including 4 disarticulations or amputations. The incidence of complications can be related to the age of the patient and to ...

95

L'exercice physique d'endurance est plus efficace que l'exercice aerobie pour le controle par la pression arterielle sur 24heures chez des diabetiques de type 2  

British Library Electronic Table of Contents (United Kingdom)

Aim: The study aimed to analyze blood pressure (BP) responses in individuals with type 2 diabetes (T2D) over a 24h period following resistance (RES) and aerobic (AER) exercise. Methods: Ten adults with T2D (age: 55.8+/-7.7 years; weight: 79.4+/-14.0kg; fasting glucose: 133.0+/-36.7mg.dL^-^1) underwent: (1) AER: 20min of cycling at 90% lactate threshold (90% LT); (2) RES: three laps of a circuit of six exercises with eight repetitions at 70% 1-RM and 40s of recovery; and (3) a control session of no exercise. Heart rate (HR), and systolic (SBP), diastolic (DBP), mean arterial (MAP) and pulse (PP) BP, as well as lactataemia (Lac), VO2, respiratory exchange ratio (RER) and rate of perceived exertion (RPE) were measured at rest, during exercise and control (CON) periods, and 60min after interve...

2011-01-01

96

Enthalpy measurements of La{sub 2}Te{sub 3}O{sub 9} and La{sub 2}Te{sub 4}O{sub 11}  

Energy Technology Data Exchange (ETDEWEB)

Enthalpy increment measurements on La{sub 2}Te{sub 3}O{sub 9}(s) and La{sub 2}Te{sub 4}O{sub 11}(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 360.70T + 0.00409T {sup 2} + 133.568 x 10{sup 5}/T - 149 923 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 3}O{sub 9} and H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 331.927T + 0.0549T {sup 2} + 29.3623 x 10{sup 5}/T - 114 587 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 4}O{sub 11}.

2007-02-01

97

Enthalpy measurements of La_2Te_3O_9 and La_2Te_4O_1_1  

International Nuclear Information System (INIS)

Enthalpy increment measurements on La_2Te_3O_9(s) and La_2Te_4O_1_1(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H"o(T) - H"o(298.15 K) (J mol"-"1) = 360.70T + 0.00409T "2 + 133.568 x 10"5/T - 149 923 (373 #<=# T (K) #<=# 936) for La_2Te_3O_9 and H"o(T) - H"o(298.15 K) (J mol"-"1) = 331.927T + 0.0549T "2 + 29.3623 x 10"5/T - 114 587 (373 #<=# T (K) #<=# 936) for La_2Te_4O_1_1.

2007-02-01

98

Effect of external pressure on intramuscular blood flow at rest and after running  

Energy Technology Data Exchange (ETDEWEB)

Local blood flow in the thigh was measured with /sup 133/Xe clearance technique in eight male distance runners after compression with a foam rubber compress and a standard elastic bandage. Two degrees of compression were tested, and an initial experiment with rested subjects was followed by a similar experiment immediately after running. Maximum compression exerted a cutaneous pressure of 85 (+/- 8) mm Hg and caused an immediate cessation of intra-muscular blood flow in the compressed area. Moderate compression gave a cutaneous pressure of 40 (+/- 5) mm Hg and resulted in a reduction of blood flow by approximately 50%. During compression, there were no significant differences in the blood flow of rested subjects compared to subjects immediately after running. In acute soft tissue injuries, a maximum compression bandage should effectively reduce or eliminate the formation of an intra-muscular hematoma, and an additive effect on blood flow of ice should not be ...

1987-10-01

99

Economic evaluation of the solar thermal co-production of zinc, synthesis gas, and hydrogen  

Energy Technology Data Exchange (ETDEWEB)

The use of concentrated solar energy for co-producing Zn and synthesis gas from Zn O and natural gas upgrades the calorific value of the initial reactants by 39% and, when compared to the traditional carbothermic reduction of Zn O, has the potential of reducing CO{sub 2} emissions by up to 78%. An economic assessment for an industrial thermochemical plant, 30 to 51 MW solar input, indicates that the cost of solar production of zinc ranges between 89-133 $/t (excluding the cost of Zn O feed and credit for pollution abatement), and thus might be competitive with conventional fossil-fuel-based processes at current fuel prices. The cost of solar H{sub 2}, produced by splitting water with zinc, is estimated to be in the range 0.10-0.14 $/kWh, and it is a favorable long term prospect once the cost of energy will account for the environmental externalities from fossil fuel burning such as the costs for CO{sub 2} mitigation and pollution abatement. (author) 1 fig., 2 ...

1999-08-01

100

Donetskgormash association in the 11th five-year plan, tasks for the 12th five-year plan  

Energy Technology Data Exchange (ETDEWEB)

This paper evaluates activities from 1981 to 1985 of the Donetskgormash association which develops and manufactures equipment for coal mining. The association has manufactured 1,410 hoists, 274 blowers and 26 bucket wheel excavators. Sixteen experimental units of new mining equipment have been developed, among others the RPM 3600-42.5/90 bucket wheel excavator (with a capacity of 3,600 m/sup 3//h for coal handling in storage yards of large power plants), the bucket wheel system used in the EhR 630-10.5/0.5 excavator and the PZ 1600-17/20 materials handling system. Among 20 equipment types manufactured from 1981 to 1985, 4 types were manufactured in the USSR for the first time (e.g. the MPP shaft sinking system and the VOD-50 mine blower). Use of new types of equipment manufactured by the association economized about 46 million rubles in coal mines. From 1986 to 1990 production of mining equipment in the association should increase by 133%; about 25.4% of equipment ...

1986-03-01

 
 
 
 
101

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of two-dimensional simulations that include ...

2001-06-01

102

Complex formation between neptunium (IV) and neptunium(V) with thiosemicarbazidodiacetic acid in solution  

International Nuclear Information System (INIS)

Complex formation between neptunium(IV) and neptunium(V) ions with thiosemicarbazidodiacetic acid in solution has been studied spectrophotometrically. Under the conditions employed herein complexes of composition 1:2 and 1:1, in the form Np(HR)_2 and NpO_2R"2"-, respectively, are formed. Stability constants for these complexes have been calculated and their molar extinction coefficients have been determined, and are equal to (1.33 +/- 0.25) x 10"7, log #beta# = 7.11 +/- 0.8, element of/sub K/ = 96 +/- 3 liter/mole x cm for Np(HR)_2, and (2.34 +/- 0.2) x 10"3, log #beta# = 3.36 +/- 0.036, element of/sub K/ = 235 +/- 1 liter/mole x cm for NpO_2R"2"-. Spectrophotometric titration has also shown that in basic solutions thiosemicarbazidodiacetic acid behaves as a tribasic acid; it third ionization constant has been determined and is equal to 10/sup -9.2/.

1988-01-01

103

Comparison of the quality of the chest film between digital radiography and conventional high kV radiography  

International Nuclear Information System (INIS)

Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct ...

2003-02-01

104

Cognitive performance correlates with cerebrovascular impairments in multi-infarct dementia  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) was measured by the "1"3"3Xe inhalation method in patients with multi-infarct dementia (MID, N = 26), Alzheimer's dementia (AD, N = 19), and among age-matched, neurologically normal, healthy volunteers (N = 26). Cognitive performance was assessed in all subjects using the Cognitive Capacity Screening Examination (CCSE). Cerebral vasomotor responses were calculated from differences in values of mean hemispheric gray matter blood flow (Delta CBF) measured during inhalation of 100% oxygen (hyperoxia) compared with CBF measured while breathing room air. Significant correlations were found between CCSE performance and vasomotor responsiveness in patients with MID (P less than .01), but not in patients with AD or in neurologically normal volunteers. Loss of vasomotor responsiveness is an indicator of cerebrovascular disease with rigidity and/or loss of reactivity of cerebral vessels, which impairs cerebrovascular responses to situational demands ...

105

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to 1500 keV, with distances ...

2009-06-07

106

Application of continuous wavelet transform to the impact location estimation of the Loose Parts Monitoring System (LPMS)  

International Nuclear Information System (INIS)

The Loose Parts Monitoring System (LPMS) provides information on the location of a loosened or detached metal impacted onto the inner surface of a primary pressure boundary and on a mass or energy of the impact signal. For the conventional system, it is popular to employ the group delay among the sensors installed within 3 ft range from the impact source in a collection zone as stated in the Reg. Guide 1.133. However, there exist inherent errors for the estimation of the true location of the impact since it is highly dependent on the plant personnel's decision to determine the arrival time differences of the generated wave group among the neighbouring sensors. To overcome this problem in this study, the two-dimensional approach has been proposed and applied to effectively estimate the arrival time differences of the impact signal by using continuous wavelet transform which is one of the linear time-frequency analysis methods. The experiment has been implemented on ...

107

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is carried out by FMS ...

2006-11-13

108

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

109

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-15

110

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-01

111

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found that Si{sup -} current of 3.8 mA and ...

1993-12-31

112

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the UV in a ...

2004-07-19

113

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

114

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...

1990-11-01

115

Vascular complications following 1500 consecutive living and cadaveric donor renal transplantations: A single center study  

International Nuclear Information System (INIS)

The aim of this study was to document vascular complications that occurred following cadaveric and living donor kidney transplants in order to assess the overall incidence of these complications at our center as well as to identify possible risk factors. In a retrospective cohort study, 1500 consecutive renal transplant recipients who received a living or cadaveric donor kidney between December 1988 and July 2006 were evaluated. The study was performed at the Nemazee Hospital, Shiraz, Iran. The assessment of the anatomy and number of renal arteries as well as the incidence of vascular complications was made by color doppler ultrasonography, angiography, and/or surgical exploration. Clinically apparent vascular complications were seen in 8.86% of all study patients (n = 133) with the most frequent being hemorrhage (n = 91; 6.1%) followed by allograft renal artery stenosis (n = 26; 1.7%), renal artery thrombosis (n = 9; 0.6%), and renal vein thrombosis (n = 7; 0.5%). ...

116

Tomographic measurements of carbon monoxide temperature and concentration in a Bunsen flame using diode laser absorption  

Energy Technology Data Exchange (ETDEWEB)

Temperature and concentration profiles of CO in a laminar, axisymmetric, premixed methane-air Bunsen flame are measured using line-of-sight diode laser absorption spectroscopy and computer tomographic (CT) reconstruction. Absorption spectra for P(20) (v=2<-1) and P(27) (v=1<-0) vibrotational transitions of CO were measured at 21 evenly spaced positions over a 1.33 cm span for a 1.3 cm radius flame. CT reconstruction algorithm was based on Fourier convolution. The tomographically reconstructed normalized transmission profiles derived from absorption spectra, in conjunction with a quantum mechanical model for vibrotational behavior of CO, yielded both temperature and concentration profiles. The Bunsen flame had 3 distinct zones: an inner rich-premixed flame zone, an outer non-premixed flame zone and an unburnt core region. The reconstructed temperature profile showed that the core region temperature was close to ambient and rapidly increased to adiabatic flame ...

1993-12-01

117

Telomerase-immortalized non-malignant human prostate epithelial cells retain the properties of multipotent stem cells  

International Nuclear Information System (INIS)

Understanding prostate stem cells may provide insight into the origin of prostate cancer. Primary cells have been cultured from human prostate tissue but they usually survive only 15-20 population doublings before undergoing senescence. We report here that RC-170N/h/clone 7 cells, a clonal cell line from hTERT-immortalized primary non-malignant tissue-derived human prostate epithelial cell line (RC170N/h), retain multipotent stem cell properties. The RC-170N/h/clone 7 cells expressed a human embryonic stem cell marker, Oct-4, and potential prostate epithelial stem cell markers, CD133, integrin #alpha#2#beta#1"h"i and CD44. The RC-170N/h/clone 7 cells proliferated in KGM and Dulbecco's Modified Eagle Medium with 10% fetal bovine serum and 5 #mu#g/ml insulin (DMEM + 10% FBS + Ins.) medium, and differentiated into epithelial stem cells that expressed epithelial cell markers, including CK5/14, CD44, p63 and cytokeratin 18 (CK18); as well as the mesenchymal cell ...

2008-01-01

118

Some important aspects of fragment angular momentum in medium energy fission of {sup 238}U  

Energy Technology Data Exchange (ETDEWEB)

Independent isomeric yield ratios of {sup 131}Te, {sup 133}Te and {sup 134}I have been determined at five different energies in the range of 25-44 MeV alpha particle induced fission of {sup 238}U using radiochemical and gamma spectrometric techniques. From the independent isomeric yield ratios, fragment angular momenta (J{sub rms}) have been deduced using a statistical model analysis. The J{sub rms} were also calculated theoretically based on thermal equilibration of various collective modes after considering the occurrence of multichance fission. These data and the literature data for various fragments in the mass region 126-136 in {sup 238}U ({alpha},f), {sup 238}U (p,f) and {sup 238}U ({gamma},f) show the following important features: (i) Both the entrance channel excitation energy and input angular momentum affect the fragment angular momentum in the exit channel. (ii) There are two groups of fission products from the point of view of change of fragment angular ...

1999-03-15

119

Si and Si/P implants in In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P  

Science.gov (United States)

Si and Si/P ion implantation doping of In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P has been studied for several Si and P doses at energies of 90 and 100 keV, respectively. For single Si implants in InGaP a maximum Hall sheet electron concentration of 1.33{times}10{sup 13} cm{sup {minus}2} is achieved for a Si dose of 5{times}10{sup 13} cm{sup {minus}2}. When an optimum dose (2.5{times}10{sup 13} cm{sup {minus}2}) P coimplant is performed this electron concentration is increased by 65{percent}. The same dose Si implants in InAlP show a maximum effective activation of 3.9{percent} with no P coimplantation and 5.2{percent} with a P-implant dose 1.5 times the silicon dose. The apparent donor ionization energies are estimated from variable temperature Hall measurements to be 2{endash}5 meV for InGaP and {approximately}80 meV for InAlP. The deeper level in InAlP is attributed to the DX level found in the Al-containing material. The reduction in sheet resistance ...

1996-06-01

120

Occupational exposure to natural radionuclides due to mining activities in Ibadan, Southwestern Nigeria  

International Nuclear Information System (INIS)

The activity concentrations of potassium, uranium and thorium in minerals and soil samples from a mining site in Ibadan, Southwestern Nigeria were measured using gamma ray spectroscopy method. Effective dose per annum has been calculated from the activity concentrations of dominant gamma-emitting natural radionuclides, potassium, uranium and thorium. Samples collected include minerals (beryl, quartz and feldspar), soil samples from the mining pits, heaps and undisturbed land around the mining site. The activity concentrations of "4"0K, "2"3"8U and "2"3"2Th, respectively in Bq kg-1 in the mineral samples were as follows: 1985 #+-# 16, 4.8 #+-# 0.9 and 11.8 #+-# 5.8 for beryl sample, 115.1 #+-# 27.9, 5.0 #+-# 1.3 and 6.3 #+-# 5.0 for feldspar samples and 1421 #+-# 122, <4.8 and 20.1 #+-# 3.5 for quartz samples. For the soil samples, the mean activity concentrations of "4"0K, "2"3"8U and "2"3"2Th, respectively, were 314.2 #+-# 5.7, 27.7 #+-# 2.6 and 11.5 #+-# 5.9 Bq kg-1 for soil ...

 
 
 
 
121

Molar heat capacities for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol at temperatures from (284 to 353) K  

International Nuclear Information System (INIS)

Isobaric specific heat capacities were measured for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol within the temperature range from (284 to 353) K, and for 2-methyl-2-butanol in the (284 to 368) K temperature interval by means of a differential scanning calorimeter. The excess molar heat capacities were calculated from the experimental results. For the temperature range from (284 to 287) K, the excess molar heat capacity is S-shaped with negative values in the 2-methyl-2-butanol rich region and with small negative values at low alcohol concentrations at temperatures from (295 to 353) K. The excess molar heat capacities are positive for all compositions under test at temperatures from (288 to 294) K. The results are explained in terms of the influence of the molecular size and configuration of the alkanols on their self-association capability and of the change in molecular structure of the (2-methyl-2-butanol + heptane) mixtures. The differences between the temperature ...

2009-03-01

122

Measurement of the weak pion nucleon coupling constant, h1(pi), from backward pion photo-production near threshold on the proton  

Energy Technology Data Exchange (ETDEWEB)

The longest range weak pion-nucleon coupling constant, h1/n is important for nuclear parity violation. However, after considerable effort in the past two decades, its value is still poorly known largely due to many-body theoretical uncertainties. Prospects of a new measurement of h1/n in a theoretically clean process are presented. A measurement of the parity-violating asymmetry in pion photoproduction off the proton is related to h1/n in a low-energy theorem for the photon polarization asymmetry at threshold in the chiral limit. At present two completed experiments - photon circular polarization for 18F and the anapole moment of 133Cs - have been interpreted to give very different values of ...

2003-05-01

123

Global warming and possibility of driving the electric cars. Chikyu ondanka to denki jidosha no kanosei  

Energy Technology Data Exchange (ETDEWEB)

The present paper explains the exhaust sources of and measures against CO2, and possibility of driving the electric cars which utilize the solar energy. In the combustion-related field, the thermal power generation attained to 24.6% which was the largest in exhaust quantity of CO2 on a division-by-division basis in FY 1990. On the consumers' side, four large consumption type industries which are steel, cement, paper, pulp and chemical industries totally occupy 64.2% of the exhaust quantity from all the industries. The emission from the cars occupies 17% of all the traffic-related exhaust quantity. The measures consist of decrease, fixation and absorption, among which the decrease is important. Newly developed electric cars comprise GM's Impact in spring, 1990, Nissan's FEN in 1991 and Tokyo Electric Power's IZA. The IZA is a 1800cc class direct drive system-driven sporty sedan which has been much improved for heightening the performance. Having four ...

1992-11-30

124

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

International Nuclear Information System (INIS)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North ...

1999-05-01

125

Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North ...

1995-05-01

126

Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents  

Energy Technology Data Exchange (ETDEWEB)

Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically ...

2008-05-15

127

Effects of acid mine drainage on a headwater stream ecosystem in Colorado  

International Nuclear Information System (INIS)

The ecological effects of acid mine drainage were investigated during the summer of 1993 on St. Kevin Gulch, a headwater stream near Leadville, Colorado. The stream currently receives acidic water from an abandoned mine. The pH downstream of the mine is between 3.5 and 4.5, and several metals exceed concentrations toxic to aquatic organisms. Zinc is present at especially high concentrations (1 to 10 mg/L) Furthermore, the stream bottom is covered with a thick layer of iron hydroxide precipitates. Effects on stream biota have been dramatic. Aquatic flora in the affected reach is limited to a green filamentous alga, Ulothrix subtilissima. Macroinvertebrate densities are significantly lower in the affected reach (mean = 99 indiv/m"2; SD = 88 indiv/M"2) compared to an upstream (pristine) reference reach (mean = 1,735 indiv/m"2; SD = 652 indiv/M"2). Functional processes were also studied in the stream. Net primary production (NPP) was measured during midday with recirculating chambers. ...

128

Dopamine transporter density of the basal ganglia in children with attention deficit hyperactivity disorder assessed with I-123 IPT SPECT  

Energy Technology Data Exchange (ETDEWEB)

Attention deficit hyperactivity disorder (ADHD) has been known as psychiatric disorder in childhood associated with dopamine dysregulation. In present study, we investigated changes in dopamine transporter (DAT) density of the basal ganglias using I-123 N-(3-iodopropen-2-yl) -2-carbomethoxy-3beta-(4-chlorphenyl) tropane (I-123 IPT) SPECT in children with ADHD before and after methylphenidate treatment. Nine drug-naive children with ADHD and seven normal children were included in the study. We performed brain SPECT two hours after the intravenous administration of I-123 IPT and made both quantitative and qualitative analyses using the obtained SPECT data, which were reconstructed for the assessment of specific/nonspecific DAT binding ratios in the basal ganglia. All children with ADHD reperformed (123I)IPT SPECT after treatment with methylphenidate (0.7mg/kg/d) during about 8 weeks. SPECT data reconstructed for the assessment of specific/nonspecific DAT binding ratio of the basal ...

2003-08-01

129

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and exposure dose. Also noted was the high ...

1985-01-01

130

Diabetic patients have abnormal cerebral autoregulation during cardiopulmonary bypass  

Energy Technology Data Exchange (ETDEWEB)

We tested the hypothesis that insulin-dependent diabetic patients with coronary artery bypass graft surgery experience altered coupling of cerebral blood flow and oxygen consumption. In a study of 23 patients (11 diabetics and 12 age-matched controls), cerebral blood flow was measured using 133Xe clearance during nonpulsatile, alpha-stat blood gas managed cardiopulmonary bypass at the conditions of hypothermia and normothermia. In diabetic patients, the cerebral blood flow at 26.6 +/- 2.42 degrees C was 25.3 +/- 14.34 ml/100 g/min and at 36.9 +/- 0.58 degrees C it was 27.3 +/- 7.40 ml/100 g/min (p = NS). The control patients increased cerebral blood flow from 20.7 +/- 6.78 ml/100 g/min at 28.4 +/- 2.81 degrees C to 37.6 +/- 8.81 ml/100 g/min at 36.5 +/- 0.45 degrees C (p less than or equal to 0.005). The oxygen consumption was calculated from jugular bulb effluent and increased from hypothermic values of 0.52 +/- 0.20 ml/100 g/min in diabetics to 1.26 +/- 0.28 ...

1990-11-01

131

DEVELOPMENT OF PROTOTYPE TITANATE ION EXCHANGE LOADED MEMBRANES FOR STRONTIUM, CESIUM AND ACTINIDE DECONTAMINATION FROM AQUEOUS MEDIA  

International Nuclear Information System (INIS)

We have successfully incorporated high surface area particles of titanate ion exchange materials (monosodium titanate and crystalline silicotitanate) with acceptable particle size distribution into porous and inert support membrane fibrils consisting of polytetrafluoroethylene (Teflon(reg_sign)), polyethylene and cellulose materials. The resulting membrane sheets, under laboratory conditions, were used to evaluate the removal of surrogate radioactive materials for cesium-137 and strontium-90 from high caustic nuclear waste simulants. These membrane supports met the nominal requirement for nonchemical interaction with the embedded ion exchange materials and were porous enough to allow sufficient liquid flow. Some of this 47-mm size stamped out prototype titanium impregnated ion exchange membrane discs was found to remove more than 96% of dissolved cesium-133 and strontium-88 from a caustic nuclear waste salt simulants. Since in traditional ion exchange based column ...

2008-05-30

132

DETECTION OF A PSEUDOBULGE HIDDEN INSIDE THE 'BOX-SHAPED BULGE' OF NGC 4565  

International Nuclear Information System (INIS)

Numerical simulations show that box-shaped bulges of edge-on galaxies are not bulges: they are bars seen side-on. Therefore, the two components that are seen in edge-on Sb galaxies such as NGC 4565 are a disk and a bar. But face-on SBb galaxies always show a disk, a bar, and a (pseudo)bulge. Where is the (pseudo)bulge in NGC 4565? We use archival Hubble Space Telescope H-band images and Spitzer Space Telescope 3.6 #mu#m wavelength images, both calibrated to Two Micron All Sky Survey K_s band, to penetrate the prominent dust lane in NGC 4565. We find a high surface brightness, central stellar component that is clearly distinct from the boxy bar and from the disk. Its brightness profile is a Sersic function with index n = 1.55 #+-# 0.07 along the major axis and 1.33 #+-# 0.12 along the minor axis. Therefore, it is a pseudobulge. It is much less luminous than the boxy bar, so the true pseudobulge-to-total luminosity ratio of the galaxy is PB/T = 0.06 #+-# 0.01, much ...

2010-06-01

133

ASPEN simulation of environmental control processes, Task 1  

Energy Technology Data Exchange (ETDEWEB)

P.S. Lowell and Co., Inc. (Lowell and Co.) and Jay S. Dweck, Consultant, Inc. (JSD) under contract to the US Department of Energy (DOE) Morgantown Energy Technology Center (METC) have developed and implemented an aqueous electrolyte calculation capability into the ASPEN (Advanced System for Process Engineering) process simulator. This report documents the efforts of Task 1 which were to implement the basic calculational capability. Task 2 involves development of several unit operations models and demonstration of the models in simulating environmental control processes in coal gasification and shale oil processing plants. Task 1 of the project involved several subtasks: selection of a chemical equilibrium algorithm; selection of activity coefficient algorithms; selection of species for inclusion in the initial implementation; collection of required data for the selected species; regression of parameters not found in the data collection effort; and installation of the chosen algorithms ...

1986-07-01

134

A study of bacterial isolates from corneal specimens and their antibiotic resistance profile  

International Nuclear Information System (INIS)

We aim to examine the spectrum of bacteria causing corneal infections and their antibiotic susceptibility patterns. This will serve as a guideline for empiric therapy of corneal infections. We conducted the study over a period of 18 months from March 2001 through December 2002 in King Abdul-Aziz University Hospital, Riyadh, Kingdom of Saudi Arabia. Corneal specimens taken from 200 patients were inoculated directly onto different types of media. The isolates were identified and then tested against the appropriate topical or systemic antibiotics. Sixty-seven (33.5%) of the total specimens were culture positive and 133 (66.5%) were culture negative. Fourteen (7%) of these showed organisms in the Gram stained smears and correlated well with the culture reports. Of the 67 positive cultures, 53 (79.1%) were Gram-positive bacteria mostly coagulase-negative Staphylococci 29 (43.3%) followed by Streptococcus pneumoniae (S. pneumoniae) 13 (19.4%). Among Gram-negative ...

135

A Dual Expandable Nitinol Stent: The Long-term Results in Patients with Malignant Gastroduodenal Strictures  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the long-term results of a dual expandable nitinol stent for the palliative treatment of malignant gastroduodenal strictures. The dual stent consists of two stents; an outer partially nylon covered stent and an inner bare nitinol stent. The outer stent was placed into the stricture and this was followed by coaxial placement of the inner bare stent. Using fluoroscopic guidance, dual expandable stents were placed in 86 patients with inoperable malignant gastroduodenal strictures. The technical and clinical success, the complication, survival and the stent patency were evaluated during the follow-up period. Stent placement was technically successful in 83 of the 86 patients. After stent placement, 74 of the 85 patients showed improvement of their symptoms. During the mean follow-up period of 133 days, 24 patients (28%) developed recurrent symptoms due to incomplete expansion (n=1), stent migration (n=4), food impaction (n=2), granulation tissue ...

2009-12-15

136

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

137

The efficacy of metallic stent placement in the treatment of colorectal obstruction  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used. Thirty of 31 attempted placements in 26 ...

2002-06-01

138

Sources of competitive advantage and business performance in the European meat processing industry  

DEFF Research Database (Denmark)

1. The aim of the paper is to investigate the relative importance of three sets of sources of competitive advantages on business performance in a specific industry context, ie the European meat processing industry. The three sets of competitive sources are Firm Specific Advantages (FSAs), Localizational Specific Advantages (LSAs) and Relationship Specific Advantages (RSAs). Based on a literature study, each set of competitive advantages is briefly described in terms of their theoretical antecedents. Seven hypotheses are formulated regarding the direct as well as the indirect relationships between the FSAs, LSAs and RSAs and business performance. Also, the direction of causality between the various sets of explanatory variables is considered. The hypotheses are combined in a structural modelling of firm competition. 2. Data and measurements are derived from a survey in the European meat processing industry in which 133 meat processors from 10 EU countries agreed to ...

1999-01-01

139

Photoproduction of J/{psi} mesons at medium and low elasticities at HERA  

Energy Technology Data Exchange (ETDEWEB)

The first analysis of inelastic J/{psi} meson production in photoproduction (Q{sup 2}<2.5 GeV{sup 2}) of the H1 experiment for the second phase of HERA (HERA II) is presented. The analysis is carried out at low and medium elasticities. The production of heavy quarks (charm, or bottom) is of special interest since the mass of the quarks provides a hard scale for the application of perturbative QCD. The muonic decay channel is used to select the J/{psi} mesons. The data was collected by the H1 detector during the period 2003-2005, and corresponds to an integrated luminosity of 133 pb{sup -1}. However only a subset of this data could be analysed. At the start of HERA II the trigger system was affected by a sizeable background. Then a fault was introduced in the trigger software during the summer 2004 and was only discovered and solved in April 2006. This means that approximately 80 % of the triggered events at medium elasticities and 65 % at low elasticities ...

2007-09-15

140

Occupational exposure to natural radionuclides due to mining activities in Ibadan, Southwestern Nigeria; Exposition professionnelle aux radionucleides naturels emis par les activites minieres a Ibadan au sud-ouest du Nigeria  

Energy Technology Data Exchange (ETDEWEB)

The activity concentrations of potassium, uranium and thorium in minerals and soil samples from a mining site in Ibadan, Southwestern Nigeria were measured using gamma ray spectroscopy method. Effective dose per annum has been calculated from the activity concentrations of dominant gamma-emitting natural radionuclides, potassium, uranium and thorium. Samples collected include minerals (beryl, quartz and feldspar), soil samples from the mining pits, heaps and undisturbed land around the mining site. The activity concentrations of {sup 40}K, {sup 238}U and {sup 232}Th, respectively in Bq kg-1 in the mineral samples were as follows: 1985 +- 16, 4.8 +- 0.9 and 11.8 +- 5.8 for beryl sample, 115.1 +- 27.9, 5.0 +- 1.3 and 6.3 +- 5.0 for feldspar samples and 1421 +- 122, <4.8 and 20.1 +- 3.5 for quartz samples. For the soil samples, the mean activity concentrations of {sup 40}K, {sup 238}U and {sup 232}Th, respectively, were 314.2 +- 5.7, 27.7 +- 2.6 and 11.5 +- 5.9 Bq kg-1 for soil ...

2010-01-15

 
 
 
 
141

Measurement of energy expenditure in overweight men and women using [C-14]-bicarbonate-urea before and after weight loss  

International Nuclear Information System (INIS)

Full text: Many studies have demonstrated significant declines in 24-hour energy expenditure (TEE) measured by whole body calorimetry with either the process of weight loss or the maintenance of reduced body weight. The aims of this study were to determine the effect of weight loss and two weeks of weight maintenance on TEE using ["1"4C]-bicarbonate-urea, Eleven subjects (6 males, 5 females), mean (#+-#SE) age 50 #+-# 3 years, BMI 34.1 #+-# 2.1 kg/m2 and body fat 38.7 #+-# 3% were studied before and after a decrease in body weight of > 8% over a period of 8 weeks, followed by two weeks of weight maintenance. Weight loss was induced using the combination of Modifast and one small meal a day (#approx#3.34 MJ/day). Body composition (DEXA), resting energy expenditure (REE) and the thermic effect of a 2.7 MJ test meal (TEF) were measured in addition to TEE at week 2 and again at week 12. Diet was assessed using diaries and physical activity energy expenditure (PAEE) was calculated from ...

2002-05-04

142

Effects of human serum on bacterial competition with neutrophils for molecular oxygen.  

Science.gov (United States)

A dialyzable factor(s) in human serum is known to stimulate gonococcal oxygen consumption. Its effect on other human pathogens was investigated. A 10% serum solution increased peak O2 consumption for Escherichia coli and Staphylococcus aureus to 157% (P less than 0.05) and 199% (P less than 0.02), respectively, of their O2 consumption when suspended in Hanks balanced salt solution, compared with a 356% increase for Neisseria gonorrhoeae with serum. Dialyzed serum lacked stimulatory capacity. Bacteria, serum, and neutrophils are often incubated to evaluate neutrophil bactericidal activity. Samples of 10(8) N. gonorrhoeae, S. aureus, and E. coli turned resazurin colorless (anaerobic conditions, Eh less than -42 mV) after 7.4, 13.3, and 15.1 min, respectively. Because neutrophil formation of reactive oxygen intermediates requires ambient O2, the effect of live bacteria and serum on this process was explored. After 5 min of incubation of 10(8) N. gonorrhoeae or S. ...

1986-06-01

143

Child mortality from solid-fuel use in India: a nationally-representative case-control study - article no. 491  

Energy Technology Data Exchange (ETDEWEB)

Most households in low and middle income countries, including in India, use solid fuels (coal/coke/lignite, firewood, dung, and crop residue) for cooking and heating. Such fuels increase child mortality, chiefly from acute respiratory infection. There are, however, few direct estimates of the impact of solid fuel on child mortality in India. Methods: We compared household solid fuel use in 1998 between 6790 child deaths, from all causes, in the previous year and 609 601 living children living in 1.1 million nationally-representative homes in India. Analyses were stratified by child's gender, age (neonatal, post-neonatal, 1-4 years) and colder versus warmer states. We also examined the association of solid fuel to non-fatal pneumonias. Solid fuel use was very common (87% in households with child deaths and 77% in households with living children). After adjustment for demographic factors and living conditions, solid-fuel use significantly increase child deaths at ages 1-4 ...

2010-08-17

144

CT in the study of thoracic-pulmonary complications after liver transplantation  

International Nuclear Information System (INIS)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) examinations had been ...

2000-12-01

145

ZZ MCJEF22NEA.BOLIB, MCNP Cross Section Library Based on JEF-2.2  

International Nuclear Information System (INIS)

1 - Description or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the JEF-2.2 evaluated nuclear data library (ACE Format). Format: ACE Number of groups: Continuous energy Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, F-19, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, Mo-98, Mo-100, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Pb-nat, Bi-209, Th-232, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-239bis, Pu-240, Pu-241, Pu-242, Am-241, Am-242, Am-242m, ...

146

ZZ MCB63NEA.BOLIB, MCNP Cross Section Library Based on ENDF/B-VI Release 3  

International Nuclear Information System (INIS)

1 - Description of program or function: Continuous energy cross-section data library for the Monte Carlo program MCNP based on the ENDF/B-VI Release 3 evaluated nuclear data library (ACE Format). Format: ACE; Number of groups: Continuous energy; Nuclides (107): H-1, H-2, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat, N-14, N-15, O-16, O-17, Na-23, Mg-nat, Al-27, Si-nat, Cl-nat, Ti-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-60, Ni-61, Ni-62, Ni-64, Zr-90, Zr-91, Zr-92, Zr-94, Zr-96, Zr-nat, Nb-93, Mo-94, Mo-95, Mo-96, Mo-97, Mo-nat, Tc-99, Ru-101, Ru-102, Ru-104, Rh-103, Pd-105, Pd-107, Ag-109, I-129, Xe-131, Cs-133, Pr-141, Nd-143, Nd-145, Pm-147, Sm-147, Sm-149, Sm-150, Sm-151, Sm-152, Eu-153, Gd-154, Gd-155, Gd-156, Gd-157, Gd-158, Gd-160, Hf-174, Hf-176, Hf-177, Hf-178, Hf-179, Hf-180, Hf-nat, Pb-206, Pb-207, Pb-208, Bi-209, Th-232,U-233, U-234, U-235, U-236, U-238, Np-237, Pu-238, Pu-239, Pu-240, Pu-241, Pu-242, Am-241, ...

147

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative change of conductivity ...

148

Development of Stronger and More Reliable Cast Austenitic Stainless Steels (H-Series) Based on Scientific Design Methodology  

Energy Technology Data Exchange (ETDEWEB)

The goal of this program was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and upper use temperature by 86 to 140 F (30 to 60 C). Meeting this goal is expected to result in energy savings of 38 trillion Btu/year by 2020 and energy cost savings of $185 million/year. The higher strength H-Series of cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat-treating industry. The project was led by Duraloy Technologies, Inc. with research participation by the Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies. Energy Industries of Ohio (EIO) was also a partner in this project. Each team partner had well-defined roles. Duraloy Technologies led the team by identifying the base alloys that were to be ...

2006-04-15

149

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

150

Quantitative analysis of spinal CSF dynamics using magnetic resonance imaging: experimental and clinical studies; MR-tomographische Liquorflussmessungen am Spinalkanal mit einem optimierten MRT-Protokoll: experimentelle und klinische Untersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Measurement of the oscillating CSF flow in the spinal canal (SC) of healthy volunteers and in patients with post-traumatic syringomyelia (PTS) using an optimized MRI protocol as well as to determine whether stenosis induced velocity changes are detectable using MRI. Methods: In 68 healthy volunteers quantitative studies of CSF flow in the cervical, thoracic, and lumbar regions were performed. First, an optimized sequence was developed and tested in 19 volunteers using four different flow-encoding velocities (4, 8, 12, 16 cm/s). Secondly, the optimized sequence was employed in 49 volunteers to measure the different CSF patterns in the cervical, thoracic, and lumbar spinal canals (CSC, TSC, LSC). Part three of the study, in which patients with PTS are being examined is still underway. We measured the maximum velocity (cm/s), the pixel area (mm{sup 2}), and the stroke volume (ml/s). Using a flow model the velocities prior to and after compression with 5 different power levels ...

2001-04-01

151

CT in the study of thoracic-pulmonary complications after liver transplantation; La Tomografia Computerizzata nello studio delle complicanze toraco-polmonari dopo trapianto del fegato  

Energy Technology Data Exchange (ETDEWEB)

In this article is reviewed the role of Computed Tomography (CT) in thoracic complications following ortho topic liver transplantation (OLT). In a post-OLT population of 567 patients transplanted in the Italian institutions, 100 patients (17.6%) were examined with chest CT. It was reviewed data relative to the total number of examinations, clinical and/or radiographic indications, the CT technique-i.e., conventional (with (out) intravenous, i.v., contrast material) or high-resolution (HRCT). It also reviewed the radiologic patterns and their correlation with the other clinical, bronchoscopic and/or laboratory results. Of 152 chest CT examinations, 45 (29.6%) were performed because of clinical indications, 31 (20.4%) because of a radiographic abnormality, 64 (42.1%) because of clinical and radiographic abnormality, 64 (42.1%) because of clinical and radiographic indications, while in 12 cases (7.9%) the reasons were unknown; 133/152 (87.5%) examinations had been ...

2000-12-01

152

WLUP3.0, 69 and 172 Group Cross Section Libraries for WIMS  

International Nuclear Information System (INIS)

Description or function: WLUP contains validated WIMS-D formatted cross section libraries in 69 and 172 energy group structures for nuclear reactor calculations. Materials from recently released evaluated nuclear data libraries are included. The NJOY nuclear data processing system was applied for generating the cross section files following the models and conventions built into the WIMS-D lattice code. The relevant features for the WIMS users are: - Energy group structures: 69 and 172 energy groups. - List of materials: WIMS ID, general information, source of data. - Cross sections: 69 and 172 group plots. - Resonance data: WIMS ID, temperature, background cross sections. - Goldstein-Cohen factors: Goldstein-Cohen lambda values. - Thermal scattering data: thermal scattering laws and P1 matrixes. - Fission spectrum: fission spectrum data. - Burnup data: burnup chains. - Fission product yields: fission yield tables. - Pseudo lumped fission product: Description of pseudo fission product. ...

153

ZZ KASHIL-E6, 175 N, 42 Gamma Groups Cross Sections in MATXS Format Based on ENDF/B-VI.5 for Shielding Applications  

International Nuclear Information System (INIS)

1 - Description of program or function: Format: MATXS; Number of groups: 175 neutron-, 42 photon-groups; 176 Nuclides: 1-H-1, 1-H-2, 1-H-3, 2-He-3, 2-He-4, 3-Li-6, 3-Li-7, 4-Be-9, 5-B-10, 5-B-11, 6-C- nat., 7-N-14, 7-N-15, 8-O-16, 8-O-17, 9-F-19, 11-Na-23, 12-Mg-nat., 13-Al-27, 14-Si-nat., 14-Si-28, 14-Si-29, 14-Si-30, 15-P-31, 16-S-32, 17-Cl-nat., 19-K-nat., 20-Ca-nat., 21-Sc-45, 22-Ti-nat., 23-V-nat., 24-Cr-50, 24-Cr-52, 24-Cr-53, 24-Cr-54, 25-Mn-25, 26-Fe-54, 26-Fe-56, 26-Fe-57, 26-Fe-58, 27-Co-59, 28-Ni-58, 28-Ni-60, 28-Ni-61, 28-Ni-62, 28-Ni-64, 29-Cu-63, 29-Cu-65, 31-Ga-nat., 39-Y-89, 40-Zr-nat., 40-Zr-90, 40-Zr-91, 40-Zr-92, 40-Zr-94, 40-Zr-96, 41-Nb-93, 42-Mo-nat., 46-Pd-102, 46-Pd-104, 46-Pd-105, 46-Pd-106, 46-Pd-108, 46-Pd-110, 47-Ag-107, 47-Ag-109, 48-Cd-106, 48-Cd-108, 48-Cd-110, 48-Cd-112, 48-Cd-113, 48-Cd-114, 48-Cd-116, 49-In-nat., 53-I-127, 54-Xe-124, 54-Xe-126, 54-Xe-128, 54-Xe-129, 54-Xe-130, 54-Xe-131, 54-Xe-132, 54-Xe-134, 54-Xe-136, 55-Cs-133, ...