WorldWideScience
1

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

2

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

3

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and ...

4

Properties of rare-gas solids. [Diffusion rate of xenon through epithelial tissue  

Science.gov (United States)

Results are reported from studies of the diffusion rate of xenon through frog abdominal skin and toad urinary bladders, typical epithelial membranes. It was concluded that intracellular water serves as the principal barrier for xenon passage through epithelial tissue.

1977-01-01

5

Ion-induced phase formation in metal-silicon systems. [Xenon ion implantation effects  

Energy Technology Data Exchange (ETDEWEB)

By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.

1985-01-11

6

Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode  

Energy Technology Data Exchange (ETDEWEB)

Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).

1991-11-15

7

sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure  

Energy Technology Data Exchange (ETDEWEB)

Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.

1990-12-15

8

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder ...

2009-04-15

9

Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen  

International Nuclear Information System (INIS)

Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the pulsed visible laser beam into the UV and frequency tripling the ...

2004-07-19

10

Multi-modality treatment of primary nonresectable intrahepatic cholangiocarcinoma with "1"3"1I anti-CEA--a Radiation Therapy Oncology Group Study  

International Nuclear Information System (INIS)

Thirty-seven patients with primary nonresectable intrahepatic cholangiocarcinoma (57% with prior treatment and/or metastasis) were prospectively treated with external radiation, chemotherapy, and "1"3"1I labelled anti-CEA. Therapy began in all trials with whole liver irradiation (21.0 Gy, 3.0 Gy/Fx, 4 days/week, 10 MV photons) with alternate treatment day chemotherapy (Adriamycin, 15 mg + 5-FU, 500 mg). One month after external beam therapy, chemotherapy was given (Adriamycin, 15 mg + 5-FU, 500 mg) followed the next day by the first administration of "1"3"1I anti-CEA. The treatment schedule used was 20 mCi day 0; 10 mCi day 5 as an outpatient. This schedule was derived from tumor dose estimates which indicated that 20 mCi (8-10 mCi/mg IgG) was sufficient to achieve tumor saturation with a tumor effective half-life of 3 to 5 days, depending upon the species of animal from which the antibody was obtained. The median tumor ...

11

Milliampere class Si{sup -} or B{sup -} negative ion extraction from RF plasma sputter type heavy negative ion source  

Energy Technology Data Exchange (ETDEWEB)

An RF plasma sputter type heavy negative ion source, which can deliver mA-class negative ion beams (12.1 mA, 1.6 mA and 2.3 mA for Cu{sup -}, C{sup -} and C{sub 2}{sup -} currents, respectively) in dc-mode operation, has been developed. In ion source, a dense plasma of 10{sup 11} cm{sup -3} order was generated in the xenon gas pressure of 10{sup -3}-10{sup -2} Pa with an rf (13.56 MHz) power of 200 - 300 W by using an RF coil, and a relatively large sputtering target of 42 mm in diameter was used. As for intense negative ion beams of silicon or boron which are important dopants for semiconductor fabrication, negative ion extraction properties of the negative ion source was investigated. The extracted total negative ion currents of 4.4 mA for a silicon target and 2.8 mA for a LaB{sub 6} target were obtained after electrons were eliminated by magnetic field near the extraction hole. From results of mass-analysis, it was found ...

1993-12-31

12

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

13

Tissue distribution of "1"3"1I radiolabeled transferrin in the athymic nude mouse: localization of a human colon adenocarcinoma HT-29 xenograft  

International Nuclear Information System (INIS)

The tissue distribution of "1"3"1I-transferrin ("1"3"1I-Tf) was studied in athymic nude mice having s.c. human colonic adenocarcinoma HT-29 xenografts. Four days after "1"3"1I-Tf injection, the "1"3"1I specific activity measured in the HT-29 tumor, i.e. amount of radioactivity per gram of fresh tissue, represented 0.31 #+-# 0.09% of the injected radioactivity and was 1.90 fold more than that measured in the murine colon (P < 0.05). After correction for intravascular "1"3"1I-Tf as estimated by mean of "9"9"mTc-Sn in vivo labeling of red blood cells, the "1"3"1I specific activity observed in the HT-29 tumor was 7.21 fold more than that observed in the murine colon. This subtracting method enabled us to localize a HT-29 tumor xenograft by #gamma# scintigraphy of the entire animal and demonstrated that "1"3"1I-Tf could be a non-specific but ...

14

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to ...

2000-01-01

15

Rapid clearance of iodine-131 MIBG from the heart and liver of patients with adrenergic dysfunction and pheochromocytoma  

Energy Technology Data Exchange (ETDEWEB)

Iodine-131 MIBG, a radiolabeled adrenergic neuron-blocking agent, decreased rapidly from the heart and liver of patients with adrenergic dysfunction and pheochromocytoma when compared with eight controls. However, there was no significant difference in the rate of (/sup 131/I)MIBG decrease in these organs between controls and patients in the intervals subsequent to 4 hr. These findings suggest that adrenergic neuronal uptake of (/sup 131/I)MIBG in these organs is smaller in the patients than in the controls. Measurements of time-activity relationships of radioiodinated MIBG may be useful for assessment of adrenergic function of these organs and thus of generalized disorders of adrenergic innervation.

1985-04-01

16

Preparation of [[sup 131]I]lipiodol as a hepatoma therapeutic agent  

Energy Technology Data Exchange (ETDEWEB)

An isotopic exchange method was used to label lipiodol with [sup 131]I. The labelling efficiency was > 92.5%, and the radiochemical purity of [[sup 131]I]lipiodol was above 98% as determined by ITLC. The influencing factors e.g. the heating temperature, reaction, pH and storage conditions were studied and the optimum conditions were determined. In a pilot study injecting [[sup 131]I]lipiodol for the treatment of hepatoma, about 70% of hepatoma patients had a response to the treatment with a reduction of [alpha]-fetoprotein and decrease of hepatoma sizes. The overall median survival was 9 months (range 2-17 months). (author).

1992-12-01

17

Half-lives of 35 radionuclides  

International Nuclear Information System (INIS)

... 67 gamma detection hafnium 180 half-life indium 111 iodine 125 iodine 131

18

Therapeutic efficacy of intralesional 131I-labelled hyaluronectin in grafted human glioblastoma  

Energy Technology Data Exchange (ETDEWEB)

The grafted human glioblastoma cell CB109 was used as a model for intralesional therapy with 131I-labelled hyaluronectin glycoprotein (131I-HN). 131I-HN bound specifically to in situ hyaluronic acid (HA), a main component of the extracellular matrix which is involved in tumour invasion. Labelling experimental conditions were determined and, finally, 25 {mu}Ci/{mu}gHN, 1 {mu}g chloramine-T/{mu}gHN and a 60-s stirring period provided a 131I-HN preparation with an optimal affinity for HA (64% compared to unlabelled HN). Following intratumoral injection, 131I-HN was retained with a limited diffusion outside the tumour. On day 4 the radioactivity concentrated in the tumour was still 25 times greater than that in the liver, spleen and kidneys combined. For therapeutic assays, 65 {mu}Ci 131I-HN was injected into the tumour, resulting in a delivery of 6.8 Gy over a ...

2000-07-01

19

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

20

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

21

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

22

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant ...

1996-12-31

23

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

24

Beam Motes  

ScienceCinema

...english the ...

26

Jet Noise Modeling for Suppressed and Unsuppressed Aircraft in - NASA  

Science.gov (United States)

Mechanisms, AGARD Conference Proceedings No. 131, 1974, Paper No. 11. ... Olsen, W. and Karchmer, A., Lip Noise Generated by Flow Separation From Nozzle ...

29

Scintigraphic demonstration of amebic liver abscesses with "1"3"1iodine labeled bromometronidazole  

International Nuclear Information System (INIS)

This case report demonstrates an hepatic amebic abscess by scintigrapy, utilizing a new radiopharmaceutical designed specifically for that purpose. The abscess is delineated as a positive lesion after twenty four hours. The agent, "1"3"1I-labeled bromometronidazole, may prove to be specific for the diagnosis of these abscesses. (orig.).

30

Nucleotide sequence and genetic analysis of a 13.1-kilobase-pair Pseudomonas denitrificans DNA fragment containing five cob genes and identification of structural genes encoding Cob(I)alamin adenosyltransferase, cobyric acid synthase, and bifunctional cobinamide kinase-cobinamide phosphate guanylyltransferase.  

UK PubMed Central (United Kingdom)

A 13.1-kb DNA fragment carrying Pseudomonas denitrificans cob genes has been sequenced. The nucleotide sequence and genetic analysis revealed that this fragment contained five different cob genes named...Full Text Available

1991-10-01

31

Localization of 131I-labeled p97-specific Fab fragments in human melanoma as a basis for radiotherapy.  

UK PubMed Central (United Kingdom)

33 patients with advanced malignant melanoma were studied after intravenous administration of 131I-labeled Fab fragments specific for p97, an oncofetal glycoprotein of human melanoma. In all, 47 gamma...Full Text Available

1983-12-01

32

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

33

Radioxenons: Their role in monitoring a Comprehensive Test Ban Treaty  

Energy Technology Data Exchange (ETDEWEB)

Monitoring for xenon radionuclides which are produced in a nuclear detonation can provide a strong deterrent to the violation of a Comprehensive nuclear Test Ban Treaty (CTBT). There are 18 known radioactive xenon isotopes produced in nuclear fission with half-lives ranging from less than one second to 11.9 days. However, only four of these remain in significant amounts more than a day after a detonation. In order for radioxenon monitoring to be practical, it was necessary to develop an automated measurement system which could operate unattended for periods of months, measure the entire spectrum of radioxenons, and provide hundreds of times better sensitivities than current laboratory procedures. This capability was developed at the US Department of Energy`s Pacific Northwest National Laboratory based on rapid separation of atmospheric xenon coupled with a unique high sensitivity measurement device for the radioxenons. A ...

1996-06-01

34

Total cross sections of ultracold neutron interactions with some gases  

Energy Technology Data Exchange (ETDEWEB)

Measurement results of total interaction cross sections averaged by the spectrum of ultracold neutrons (UCN) within the rate range from 3.2 to 5.7 m/s at the temperatures of 80 and 300 K for the following gases: hydrogen, parahydrogen, helium-4, nitrogen, neon, argon, xenon are presented. The experiment has been conducted conducted in the facility for UCN extraction, mounted in the radial channel of the WWR-K reactor. Experimental dependences of UCN counting rate on pressure of the investigated gases in the chamber varying from 0 to 1.5x10/sup 3/ torr are presented graphically. The measured total cross sections mainly satisfactorily agree with calculations, divergences are observed only for hydrogen and xenon.

1981-11-01

35

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

36

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

37

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

38

Combining iodine-131 Lipiodol therapy with low-dose cisplatin as a radiosensitiser: preliminary results in hepatocellular carcinoma  

Energy Technology Data Exchange (ETDEWEB)

A prospective pilot trial was performed in 20 patients randomised to receive either {sup 131}I-Lipiodol therapy alone (n=10) or {sup 131}I-Lipiodol combined with a short low-dose cisplatin infusion (n=10), the aim being to evaluate the possible positive influence of a radiosensitiser on toxicity and tumour response. An activity of 1,354-2,128 MBq (mean 1,824 MBq) [36.6-57.5 mCi (mean 49.3 mCi)] {sup 131}I-labelled Lipiodol was administered by selective instillation in the hepatic artery. Cisplatin was given in a dose of 30 mg/m{sup 2} at day -1 and day +6 (day 0: {sup 131}I-Lipiodol). The primary endpoint of this trial was toxicity of therapy; points of secondary interest were tumour response and survival at 6 months. With the use of cisplatin we found a higher percentage of stable or diminished tumour size (90%, vs 40% without). A benefit in group survival at 6 months was not evident. Low-grade ...

2002-07-01

39

Radiolabelled peanut lectin for the scintigraphy detection of cancer  

International Nuclear Information System (INIS)

To investigate the role of intravenously administered, radioiodinated peanut lectin ("1"3"1I-PNA) in the non-invasive detection of cancer, the pharmacokinetics and scintigraphic distribution of this novel tumor-seeking compound were studied in 8 patients with metastatic cancer of the colon, breast or lung. Scintigraphic localization of "1"3"1I-PNA was apparent at certain anatomical sites of known metastases in 2 patients and in a further 2 patients an adjacent malignant pleural effusion was visualized. The rapid clearance of radioactivity from the whole body and plasma with marked renal concentration and rapid urinary excretion of significant amounts of intact "1"3"1I-PNA (mol.wt. 107,000,pI 5.95) implied that this molecule was excreted selectively by the renal tubules. PNA or other lectins may find a role in the scintigraphic detection of selected types of cancer. (author).

1984-01-01

40

211At-Rh(16-S4-diol) as a starting complex for preparing an astatine-labeled radiopharmaceutical  

British Library Electronic Table of Contents (United Kingdom)

A new procedure for preparing an 211At-labeled radiopharmaceutical is suggested. The 211At? anion forms a strong bond with the Rh3+ cation incorporated in the complex with a thiother ligand, 1,5,9,13-tetrathiacyclohexadecane-3,11-diol (16-S4-diol). The reaction conditions are optimized with 131I as astatine analog. The complexes are studied by paper electrophoresis, ion exchange, and thin-layer chromatography. The kinetics of the addition of the 131I? anion to Rh(16-S4-diol) and the dependence of the yield of the forming complex 131I-Rh(16-S4-diol) on the temperature, solution acidity, and reactant concentrations are examined. Taking into account the results obtained, the complex 211At-Rh(16-S4-diol) is prepared by adding astatide (211 At?) to equivalent amounts of RhCl3 and the tetrathioe...

2008-01-01

41

Beam-beam compensation activities at Fermilab. R and D status  

International Nuclear Information System (INIS)

The beam-beam interaction in the Tevatron produce the betatron tune spread in each bunch and a bunch-to-bunch tune spread. The tune spread sets limits on bunch intensity and luminosity. The beam-beam effects for antiprotons are usually more severe since the proton bunch population is higher. The beam-beam effects for antiprotons can in principle be compensated with the use of an electron beam with a corresponding charge density. The status of studies of possibilities of the beam-beam compensation is reviewed in this paper.

1999-06-09

42

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

43

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

44

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

45

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

46

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

47

Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)  

Energy Technology Data Exchange (ETDEWEB)

The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with ...

1988-04-01

48

Lizards in the ecology of salmonellosis in Panama.  

UK PubMed Central (United Kingdom)

Enteropathogenic bacteria was isolated from 131 of 447 (29.4%) neotropical Panamanian lizards belonging to 34 species of seven families. Overall, 147 strains of bacteria were isolated comprising 26...Full Text Available

1981-05-01

49

Geologic Structure and Hydrodynamics of Egmont Channel: An Anomalous Inlet at the Mouth of Tampa Bay, Florida  

Science.gov (United States)

... at depths greater than 29 m. Egmont Deep Seismic Stratigraphy Seismic profile data indicate that both the mouth ... 131. CrossRefDuncan, D. S. 1993. Neogene to Recent Seismic Stratigraphy of the Lower ...

50

Food as a Component of National Defense Strategy  

Science.gov (United States)

... As noted by Emma Rothschild: ... 24. Emma Rothschild, "Food Politics," Foreign Affairs, 54 (January 1976),285·86. 25. Forecast 90, pp. I1·31, 32. 26. ...

2011-05-15

51

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected ...

1989-08-15

52

Uptake of iodine-131 in gaseous state on Ag-impregnated amberlite IR-120 resin and its comparison with activated charcoal. [dry and wet conditions  

Energy Technology Data Exchange (ETDEWEB)

The paper describes uptake of gaseous lodine-131 on silver impregnated organic resin, Amberlite IR-120, available at the Secondary Steam Generator (S.S.G.) Opening at T.A.P.S. in comparison with activated charcoal. The experiments are conducted in dry and wet conditions by soaking the impregnated resin and activated charcoal in distilled water for wet condition. The paper also describes the iodine sampler specially designed and fabricated for these experiments.

1982-01-01

53

Intra-arterial injection of 131-I-Lipiodol in the treatment of hepato-cellular carcinoma; Lipiocis et carcinome hepato-cellulaire  

Energy Technology Data Exchange (ETDEWEB)

The incidence of hepatocellular carcinoma (HCC) is increasing in developed countries and the general status of HCC patients is now by far better than a few years ago, allowing physicians to propose some different treatments of these patients. Among these treatments, intra-arterial injection of 131-iodine-labelled Lipiodol could be used in palliative, curative or adjuvant settings. After a brief summary of the modalities of this treatment, requiring the collaboration of Gastro-enterologists, Oncologists, Radiologists and Nuclear Medicine physicians, the different possibilities of therapeutic uses of this new approach are described and an outlook of these developments is proposed. (author)

2001-11-01

54

I-131 labelled peanut lectin renal kinetics in cis-platin induced tubular toxicity in dogs  

International Nuclear Information System (INIS)

Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree ...

1985-06-02

55

Beam stability study based on the beam trajectory jitter in the KEKB injector linac  

International Nuclear Information System (INIS)

... Tsukuba, Ibaraki (Japan) 389 p. PARTICLE ACCELERATORS beam monitoring

2001-08-01

58

Radioiodine dosimetry and prediction of consequences of thyroid exposure of the Russian population following the Chernobyl accident  

International Nuclear Information System (INIS)

In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in adult inhabitants of the Bryansk region was ...

59

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, ...

60

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

Energy Technology Data Exchange (ETDEWEB)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (Llambda) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-..delta.. Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate Llambda and LCBF using a least squares curve fitting analysis. Calculated Llambda and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of Llambda and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are discussed.

1988-07-01

61

Measurement of local cerebral blood flow by computerized tomography with inhalation of stable xenon and curve-fitting method  

International Nuclear Information System (INIS)

Non-invasive methods are described for estimating local cerebal blood flows (LCBF) and local partition coefficients (L#lambda#) during inhalation of 30 % stable xenon gas (Xe) in oxygen during CT scanning. After the denitrogenation with pure oxygen breathing, 30 % Xe is inhaled for four minutes to minimize subanesthetic effects with a rubber facemask and the delivery system of Xe. Local time-#DELTA# Hounsfield units curve during the Xe wash-in and wash-out phase is utilized in order to calculate L#lambda# and LCBF using a least squares curve fitting analysis. Calculated L#lambda# and LCBF with the new method manifested reasonable distribution between the grey and white matters, and reproducibility was excellent in our study. Several case studies of patients with cerebral infarction are presented to demonstrate the characterization of L#lambda# and LCBF patterns in various tissues and theoretical grounds underlying the new method of curve fitting analysis are ...

62

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

63

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

64

Advanced concepts report on the detection of xenon with a miniature whole air sampler capable of extended operating times  

Energy Technology Data Exchange (ETDEWEB)

Many monitoring activities require the collection of whole air samples over an extended time interval without loss or concentration of any atmospheric constituents. Described is the development and laboratory testing of a whole air sampler capable of collecting a 100 liter sample over a period of 0.63 days. The sampler has an empty weight of 7.79 kg and an overall size of 20.8-cm {times} 20.8-cm {times} 66.1-cm. The conceptual design for the development of smaller, higher-performance whole air samplers is also reported.

1993-07-01

65

A NEM diffusion code for fuel management and time average core calculation  

International Nuclear Information System (INIS)

A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)

2005-11-01

66

Use of gadolinium as neutron poison in 540 MWe PHWR  

International Nuclear Information System (INIS)

In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different operating conditions. These neutron ...

2006-11-13

67

The use of "1"3"1I-radioiodine in diagnostic and treatment: estimated risk in Guanabara  

International Nuclear Information System (INIS)

The "1"3"1-radioiodine use in Guanabara area, during 1972-1973, is analysed. References are made to the radiation levels delivered to thyroid, bone marrow and gonads in a population of 27000 people examined by tracer techniques, 190 submitted to hyperthyroidism treatment and 50 treated for thyroid cancer. The pertinent literature gives some data concerning radiation induced cancer (leukaemia and thyroid cancer). By this, it was possible to estimate the probability of tumour occurrence in that population, assuming a linear relationship between dose and effect. The conclusions are the followings: 1 - there are many duties in this field at the present; 2 - the leukaemia incidence related to the 131-radioiodine use is negligible, either in diagnostic or therapeutic modalities; 3 - the possibility of thyroid tumors induced by radiation is real, specially in hyperthyroidism treatment; 4 - the use of tracer techniques that cause lower irradiation to ...

68

"2"1"1At-Rh(16-S4-diol) - initial complex of radiopharmaceuticals labelled with astatine  

International Nuclear Information System (INIS)

Paper describes a new procedure to synthesize a pharmaceutical containing "2"1"1At. "2"1"1At"- anion was found to bind strongly with Rh"3"+ cation complexing with a thio-ether ligand - 1,5,9,13-tetratiacyclohexadecane-3,11-diol (16-S4-diol). One made use of "1"3"1I isotope to seek for the optimal conditions of the reaction. The derived complexes were studied by means of the paper electrophoresis, the ion exchange, the surface chromatography. One studied the kinetics of "1"3"1I"- anion binding with Rh(16-S4-diol), the dependence of the yield of "1"3"1I-Rh(16-S4-diol) forming complex on the temperature. the acidity of the reaction mixture and the concentration of the reagents. On the basis of the determined conditions of the synthesis one prepared "2"1"1At-Rh(16-S4-diol) complex by more astatide ("2"1"1At"-) to the equivalent amounts of RhCl_3 and tetra-thio-ether (16-S4-diol). One studied its behaviour

69

Stabilization of synchrotron radiation beam at HASYLAB  

Energy Technology Data Exchange (ETDEWEB)

At DORIS II/HASYLAB a vertical beam position control system is in regular operation. It controls the position and angle of a photon beam simultaneously, and can stabilize beam movements up to frequencies of 0.1 Hz. To suppress beam vibrations up to 50 Hz and above, a prototype beam stabilization system for these frequencies was built and tested successfully. The present beam oscillations at the HASYLAB beamlines are explained, the quality of the beam position control system and the results of the prototype test are presented.

1989-07-01

71

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

72

Panel session: Transport of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)

1987-07-30

73

Treatment of hepatocellular carcinoma (HCC) with radiolabeled Lipiodol: a preliminary report  

Energy Technology Data Exchange (ETDEWEB)

Fatty acid esters such as Lipiodol or Ethiodol are known to selectively localize in vascular hepatocellular carcinomas (HCC), following intraarterial hepatic administration. Lipiodol was labeled with radioactive /sup 131/I and administered in 47 patients with HCC for both imaging and therapy. The short term preliminary results suggest radiolabeled Lipiodol is effective in eliminating ascites, shrinking the tumor by a high internal radiation dose, and in improving symptomatology of these tumors. In the future, /sup 90/Y, which is a stronger pure beta-emitter (maximum beta energy of 2.27 MeV, a half life of 64 h, and a maximum penetration or beta range of 11mm), than /sup 131/I will be used for more effective treatment of HCC.

1987-12-01

74

High-resolution primary ion beam probe for SIMS  

Energy Technology Data Exchange (ETDEWEB)

High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.

2004-06-15

75

Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals  

Energy Technology Data Exchange (ETDEWEB)

A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.

1995-12-01

76

PWR FISSION PRODUCT ACTIVITY LEVELS  

Science.gov (United States)

Recent radiochemical investigations of the PWR reactor coolant have corfirmed earlier observations that the level of activities of 33 m Cs/sup 138/, 2.8 hr Kr , and 8.1 day 1/sup 131/ are more than ten times higher than those predicted for the estimated U contamination of the Zircaloy cladding. The present fission product activity levels have not, as yet, presented any problems in the PWR. (W.L.H.)

1958-05-01

77

Monoclonal antibody imaging in malignant and benign gastrointestinal diseases  

International Nuclear Information System (INIS)

The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).

78

Internal emitter limits for iodine, radium and radon daughters  

Energy Technology Data Exchange (ETDEWEB)

This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

1984-08-15

79

Dosimetric evaluation and therapeutic response to iodine-131 labelled lipiodol in treatment of hepatocellular carcinomas; Evaluation dosimetrique et reponse therapeutique de la curietherapie metabolique des hepatocarcinomes par le lipiodol marque par l'iode 131  

Energy Technology Data Exchange (ETDEWEB)

Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total biological response rate is ...

2006-12-15

80

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

81

Antitumor activity of platinum(II) complexes with histamine and radioiodinated histamine in a transplantable murine adenocarcinoma model  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Antitumor activity of the dichloroplatinum(II)-histamine complexes labeled with I-125 or I-131 was investigated in a transplantable murine adenocarcinoma (MA) model. Methods: The tumor model was obtained in C3H/W female mice after subcutaneous inoculation of the tumor cells derived from the mice bearing a mammary tumor of spontaneous origin. Antitumor activities of the platinum-histamine complexes were investigated in three independent experiments, which differed in applied doses of preparations (PtCl{sub 2}Hist, PtCl{sub 2}[{sup 125}I]Hist, PtCl{sub 2}[{sup 131}I]Hist, PtCl{sub 2}Hist/PtCl{sub 2}[{sup 125}I]Hist and PtCl{sub 2}Hist/PtCl{sub 2}[{sup 131}I]Hist), treatment schedules as well as stages of the disease progress in the animals used. Experiment 1 included long-term, multidose treatment with low single doses (treatment duration 31-32 days; 8-10 doses of ca. 0.25{center_dot}MTD{sub Pt} each). Experiment 2 ...

2008-07-15

82

Time-Dependent Propagation of High-Energy Laser Beams ...  

Science.gov (United States)

... Law Parameter 28 Summary 28 6. CIRCULAR VS ANNULAR LASER BEAMS 29 7. HIGH-ENERGY LASER BEAM PROPAGATION THROUGH A ...

1977-12-14

83

Target stations and beam dumps for the CERN SPS  

International Nuclear Information System (INIS)

The design of the absorber blocks for internal and external dumping of the SPS proton beam is discussed. In addition, the external target stations for slow and fast extracted proton beams are described.

1977-03-16

85

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

89

Beam-forming system for electrostatic accelerator  

International Nuclear Information System (INIS)

A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.

1988-01-01

90

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

91

Thermal degradation of wood during photodegradation  

British Library Electronic Table of Contents (United Kingdom)

In this study, wood samples were exposed to light irradiations (direct sunlight, xenon lamp, mercury vapour lamp) and thermal treatments were carried out in dry- and in humid conditions at 90degreeC. One part of the samples was covered by an aluminium plate during light irradiation. The samples under the aluminium plate also suffered considerable chemical changes, monitored by infrared technique and colour measurement. The sunlight produced greater colour change under the aluminium plate than the artificial light sources. During light irradiation, the carbonyl band having two maximum at 1700 and 1746cm-1 increased and the peak of the aromatic skeletal vibration arising from lignin (1510cm-1) decreased together with the guaiacyl vibrations at 1275cm-1. There was absorption decrease at 1174c...

2011-01-01

92

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

93

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

94

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

95

Uses of laser optical pumping to produce polarized ion beams  

Energy Technology Data Exchange (ETDEWEB)

Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.

1983-04-01

96

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge  

Science.gov (United States)

Scratch and Corrosion Resistance of an Aluminum Flange with an Electron Beam Modified Seal Edge

2011-01-01

97

Production of a helium beam in a focused ion beam machine using an electron beam ion trap  

International Nuclear Information System (INIS)

Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.

2007-02-19

98

Low-energy high-current electron beam generation in plasma systems and beam-plasma interaction  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

99

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

101

Current results from the Texas A and M electron beam ion source  

International Nuclear Information System (INIS)

The electron beam ion source (EBIS) at Texas A and M University was constructed and is currently undergoing tests on the injection and transmission of the electron beam through the solenoid. Results of computer simulation of the electron beam are presented, as well as measurements of electron beam profiles using a pinhole beam analyzer.

102

Beam stability in a 6 GeV synchroton light source  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the effects of motion of beam components (quads, rf cavities and dipoles) on the beam and considers the properties of a compensation system from the perspective of users. The system departs from standard practice in considering active perturbation of the electron beam to verify beam corrections. The effects of local closed orbit perturbations to direct undulator beams at different experimental setups are also considered.

1985-10-01

103

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam ...

1995-12-31

104

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is mainly due to the strong hydrogen bonding in these fluids. A third group includes adsorptives such as benzene, where the heat ...

2008-05-24

105

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive, simplified method using inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r{lambda}) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe{sup s} and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe{sup s} washin and washout phases was used to calculate r{lambda} and rCBF using least squares curve fitting analysis. The resultant r{lambda} and rCBF map demonstrated a reliable distribution between the gray and white matter, and ...

1991-02-01

106

Cerebral blood flow measurement using stable xenon CT with very short inhalation times  

International Nuclear Information System (INIS)

A noninvasive, simplified method using inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning to estimate regional cerebral blood flow (rCBF) and regional partition coefficient (r#lambda#) is described. Twenty-four patients with cerebrovascular occlusive disease and six volunteer controls inhaled 30% Xe"s and 70% oxygen for 180 seconds and exhaled for 144 seconds during serial CT scanning without denitrogenation. The end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) for arteries with the curve fitting method. The time-CT number (Hounsfield unit) curve for cerebral tissue during the Xe"s washin and washout phases was used to calculate r#lambda# and rCBF using least squares curve fitting analysis. The resultant r#lambda# and rCBF map demonstrated a reliable distribution between the gray and white matter, and infarcted areas. rCBF ...

107

GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.  

Science.gov (United States)

1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased from 8.0 to 12.5 per cent/day. 4. No differences were noted in the metabolism of homologous or autologous gamma globulin ...

1964-04-01

108

Transverse velocity modulated e-beam propagating through an undulator as a source of coherent spontaneous radiation  

International Nuclear Information System (INIS)

A new kind of e-beam bunching enabling the production of coherent spontaneous emission (CSE) is proposed and considered. It is shown that an e-beam in passing through an undulator will induce CSE along with incoherent spontaneous radiation on the same wavelength if the e-beam transverse velocity is modulated with a spatial period twice as long as the radiation wavelength. Such angular modulated beams can be regarded as alternatives to conventionally density modulated beams for CSE production. Requirements for e-beams are similar in both cases.

1999-06-01

109

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

110

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

111

Method and apparatus for efficient photodetachment and purification of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ion guide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ion guide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.

2008-02-26

112

Therapy of children with Ewing's sarcoma  

International Nuclear Information System (INIS)

Combined treatment of 131 patients aged 3-16 with local form of Ewing's sarcoma is carried out. Survival rate per year was studied in patients without diagnosed metastases depending on chemiotherapy method. It is stated that improved results of treatment of children with Ewing's sarcoma may be achieved by combining radiotherapy with long-term systemic polychemotherapy. The most efficient and expedient method of radiotherapy of long bone sarcoma in children is dialy three-field irradiation with 2 Gy at SFD to the tumor 60 Gy, and adjacent tissues - 40 Gy.

113

Steam turbines. Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the general market conditions, the construction of steam turbines was greatly reduced in 1987. As in 1986, it came to a downward movement. This situation will heighten in the coming years. The exploitation of devices, which are available by way of the development of EDP in computation, construction, production and operation, leads to considerable improvements. These improvements can only be employed gradually, due to the reduction in production. However, technological progress can be used economically in part in the restoration of old installations. Here turbine construction, the thermodynamical interpretation of gas and steam turbines, developments in the field of conduction technology, piping and materials are described. Also improvements in operation security and operation supervision of the installations is treated, as well as service and maintenance of the plants. (BR) With 131 refs.

1988-04-01

114

Effect of lead nitrate on thyroid function on the Indian palm squirrel, Funambulus pennanti (Wroughton)  

Energy Technology Data Exchange (ETDEWEB)

Some of the known toxic effects of lead in mammals including man are, impaired heme synthesis, anemia, nepatopathy, nephropathy, behavioral disorders and neuropathy. However, very little is known about the effect of lead on endocrine physiology. Some data are available on lead induced impairment of thyroid function in occupationally exposed men and experimental rats. As lead nitrate is largely consumed through water and food, in this study the wild rodents Funambulus pennanti were administered lead through their drinking water and their thyroid structure, radioiodine 131-I percentage uptake and protein bound iodine (PBI) level were assessed.

1987-06-01

115

2007 SB14 Source Reduction Plan/Report  

Energy Technology Data Exchange (ETDEWEB)

Aqueous solutions (mixed waste) generated from various LLNL operations, such as debris washing, sample preparation and analysis, and equipment maintenance and cleanout, were combined for storage in the B695 tank farm. Prior to combination the individual waste streams had different codes depending on the particular generating process and waste characteristics. The largest streams were CWC 132, 791, 134, 792. Several smaller waste streams were also included. This combined waste stream was treated at LLNL's waste treatment facility using a vacuum filtration and cool vapor evaporation process in preparation for discharge to sanitary sewer. Prior to discharge, the treated waste stream was sampled and the results were reviewed by LLNL's water monitoring specialists. The treated solution was discharged following confirmation that it met the discharge criteria. A major source, accounting for 50% for this waste stream, is metal machining, cutting and grinding operations in the ...

2007-07-24

116

Study of the distribution of gamma emitters radionuclides between a pollution abatement factory and its surrounding environment; Case of the water treatment plant of the Grand Caen district. Study report; Etude de la repartition de radionucleides artificiels emetteurs gamma entre une usine de depollution et son milieu environnant; Cas de la station d'epuration du District du Grand Caen. Rapport d'etude  

Energy Technology Data Exchange (ETDEWEB)

Except nuclear industry, diverse structures (hospitals, of research or manufacturers) can have appeal to the use of radioisotopes conditioned under unsealed shape. Such practices lead to tolerate releases in environment in the respect of a statutory device. So the collective network can contain radioisotopes the future of which is going to depend partially on the cleaning applied to waste water. This study through the analysis of a concrete case, has for objective to inform about the future of gamma radioelements present in waste water treated by a wastewater treatment plant. The contamination of the network is essentially due to Tc{sup 99} and I{sup 131}, radioelements present whatever the working day and the hour considered. The total estimated in-load for a day is important, of the order of 4000 MBq for Tc{sup 99} and 15 to 300 MBq for I{sup 131}. The assessment of cleaning of the station shows that this one plays a role towards this ...

2007-07-01

117

Effect of Kerr nonlinearity on an Airy beam  

International Nuclear Information System (INIS)

The effect of Kerr nonlinearity on an Airy beam is investigated by using the nonlinear Schroedinger equation. Based on the moments method, the evolution of the Airy beam width in the rms sense is analytically described. Numerical simulations indicate that the central parts of the major lobe of the Airy beam initially give rise to radial compression during propagation in a focusing medium, even though the rms beam width broadens. The partial collapse of the center parts of the major lobe of the beam appear below the threshold for a global collapse. The evolutions of the field distributions of the Airy beams are different during propagation in different Kerr media while the beams still travel along the parabolic trajectory just as the beam propagates in free space.

2010-10-01

118

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

119

Improved FNAL linac beam choppers  

Energy Technology Data Exchange (ETDEWEB)

A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.

1981-06-01

120

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

121

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

122

Beam position monitor sensitivity for low-[beta] beams  

Energy Technology Data Exchange (ETDEWEB)

Design of a beam position monitor (BPM) which is sensitive to low velo charged particle beams is considered. Quantitative estimates are made for the corrections to the conventional approximations to solutions of the Laplace Equation in two-dimensions when a BPM is used to measure to position of low velocity (low-[beta]) beams. (AIP)

1994-10-10

124

Motion compensation with a scanned ion beam: a technical feasibility study  

UK PubMed Central (United Kingdom)

BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available

125

Low energy focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

The performance of the PSI/ETH focused ion beam (FIB) system has been improved to produce ion beams of very low energies down to 40 eV with a reasonable spot size of 1 {mu}m at 200 eV. (author) 2 figs., 1 ref.

1996-10-01

126

Drift compression and final focus of intense heavy ion beams  

Energy Technology Data Exchange (ETDEWEB)

The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.

2003-05-01

127

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

128

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

129

Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

A method for conditioning electron beams is proposed, making use of the TM{sub 210} mode of microwave cavities, to reduce the axial velocity spread within the beam, in order to enhance gain in resonant electron beam devices, such as the free-electron laser (FEL). Effectively, a conditioner removes the restriction on beam emittance. The conditioner is analyzed using a simple model for beam transport and ideal RF cavities. Analysis of an FEL is employed to evaluate performance with reduced axial velocity spread. Examples of FELs are presented showing the distinct advantage of conditioning.

1991-07-01

130

Production of polarized negative ion beams by collisional pumping  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1983-01-01

131

Production of polarized negative ion beams by ''collisional pumping''  

Energy Technology Data Exchange (ETDEWEB)

The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.

1984-03-01

132

Large ion beams, fundamentals of generation and propagation  

Energy Technology Data Exchange (ETDEWEB)

This book is a compliation and analysis of discussions of phenomena important to ion beams and high perveance ion beams. This text discusses physics essential to research on ion beam generation and propagation and provides some requisite background to understanding the criteria for designing electrodes. Ion sources are categorized in terms of their configurations, and the relationships between various types of sources is developed. Covers collisionless space charge phenomena, collisionless plasmas, collisional effects and the taxonomy of high poissance beams. Chapters also treat the field of intense negative ion beams.

1987-01-01

133

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-01-01

134

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

135

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1993-04-01

136

Focusing atomic beams by the dissipative radiation-pressure force of laser light  

Science.gov (United States)

An experimental realization of the focusing of an atomic beam by a spontaneous radiation pressure force is reported. A simple light field configuration for focusing an atomic beam is described which is formed by four divergent Gaussian laser beams propagating along the + or - x and + or - y directions of a Cartesian coordinate system. An experimental arrangement for the laser focusing is shown, and the experimental procedure is described. The resulting atomic beam profiles are shown and discussed. It is concluded that the experiments open up the possibility of gaining control over such parameters of atomic beams as their density and divergence. 7 references.

1986-02-01

137

Electro-static beam steering mechanism for a high current negative ion beam consisting of multi-beamlets  

Energy Technology Data Exchange (ETDEWEB)

An electrostatic beam steering mechanism (ESM) has been designed and tested to deflect negative ion beams consisting of multi-beamlets. A steering angle of 10 mrad was obtained within the deviation of less than 1 mrad by biasing two electrodes at 0.5 kV and -0.75 kV for 120 keV H{sup -} ion beam. The current flowing to the positive electrode was no more than 10% of the beam current at a pressure of 2.8x10{sup -5} Torr. (author)

1998-11-01

138

Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis  

Energy Technology Data Exchange (ETDEWEB)

A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.

2003-01-15

139

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

140

Centroid and Envelope Dynamics of High-intensity Charged Particle Beams in an External Focusing Lattice and Oscillating Wobbler  

Energy Technology Data Exchange (ETDEWEB)

The centroid and envelope dynamics of a high-intensity charged particle beam are investigated as a beam smoothing technique to achieve uniform illumination over a suitably chosen region of the target for applications to ion-beam-driven high energy density physics and heavy ion fusion. The motion of the beam centroid projected onto the target follows a smooth pattern to achieve the desired illumination, for improved stability properties during the beam-target interaction. The centroid dynamics is controlled by an oscillating "wobbler", a set of electrically-biased plates driven by RF voltage. __________________________________________________

2010-04-28

141

Beam position monitor readout and control in the SLC linac  

Energy Technology Data Exchange (ETDEWEB)

A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.

1985-04-01

142

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

143

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

144

Adiabatic Rormation of a Matched-beam Distribution for an Alternating-gradient Quadrupole Lattice  

Energy Technology Data Exchange (ETDEWEB)

The formation of a quasiequilibrium beam distribution matched to an alternating-gradient quadrupole focusing lattice by means of the adiabatic turn-on of the oscillating focusing field is studied numerically using particle-in-cell simulations. Quiescent beam propagation over several hundred lattice periods is demonstrated for a broad range of beam intensities and vacuum phase advances describing the strength of the oscillating focusing field. Properties of the matched-beam distribution are investigated. In particular, self-similar evolution of the beam density profile is observed over a wide range of system parameters. The numerical simulations are performed using the WARP particle-in-cell code.

2010-02-02

145

2D Electrostatic Simulation of the Modulated Electron Beam Interaction with Inhomogeneous Plasma  

International Nuclear Information System (INIS)

Electrostatic plasma simulation code for 2D rectangular geometry is presented. Main distinguishing feature of the code is its orientation on the beam-plasma interaction. The code and its graphical interface were developed using MATLAB programming language. Simulation results of inhomogeneous plasma interaction with modulated electron beams of different width are compared. In case of wide beam the front of Langmuir waves generated in point of local plasma resonance is planar and in case of thin beam (or ribbon beam) the front has approximately half-circular form.

2006-01-01

146

Workshop on Dynamics and Aeroelastic Stability Modeling of ...  

Science.gov (United States)

... Each beam finite element was derived using Hamilton's principle and the following basic assumptions: the beam has an arbitrary amount of pretwist ...

1990-03-14

147

Theo de Visser and Farshid Feyzi in front of main beam of YE3 cart.  

CERN Multimedia

Theo de Visser and Farshid Feyzi in front of main beam of YE3 cart at HHM in Shanghai.

2000-01-01

148

The development of high-intensity negative ion sources and beams in the USSR. Technical report  

Energy Technology Data Exchange (ETDEWEB)

This report reviews Soviet R and D of (1) high-intensity negative ion sources and (2) transport and focusing of negative ion beams, using Soviet open literature of the past ten years, and correlates this data with data on Soviet institutes responsible for negative ion beam development. The Soviets are developing intense negative ion beams as the basis for creating neutral beams for injection into mirror traps and tokamaks, for inertial confinement fusion, and possibly for exoatmospheric beam weapon applications. The report focuses specifically on surface-plasma-type ion sources, which were first developed in the USSR and which show great promise for creating beams of high intensity, high brightness, and low emittance. Mechanisms for optimum negative ion beam transport are also discussed.

1981-09-01

149

Study of the Electron Beam Dynamics in the Fermi @ Elettra Linac  

Energy Technology Data Exchange (ETDEWEB)

A study of the electron beam dynamics in the linac is conducted for the FERMI free electron laser (FEL) founded for construction at the Sincrotrone Trieste.

2006-07-19

150

Study of the Electron Beam Dynamics in the FERMI @ ELETTRALinac  

Energy Technology Data Exchange (ETDEWEB)

A study of the electron beam dynamics in the linac is conducted for the FERMI free electron laser (FEL) founded for construction at the Sincrotrone Trieste

2006-06-17

151

Studies of Non-Linear Optical Effects for Agile Beam Steering  

Science.gov (United States)

... electronic feedback system' connected to a Q switch ... The use of acousto-optic (AO) beam steering devices for BMDO (SDI) applications is very ...

1993-11-01

153

Stability of space-charge neutralized beams  

Science.gov (United States)

Consideration is given to the stability of negative ion beams which are neutralized through ionization of a background gas. Two types of instabilities are examined. First, beam-plasma instabilities are analyzed with the dispersion relation showing that they are unimportant if the beam velocity is less than the electron thermal velocity. Second, results of a computer simulation on the flow of a cylindrical beam and the resulting background plasma show that when the background neutral gas density is less than or approximately equal to a critical density as instability occurs. This critical density is the density that would be needed to space-charge neutralize the beam if the positive ions were not retarded by the beam. An approximate dispersion relation indicates that the nature of the instability is a transverse positive-ion acoustic wave which couples to the ...

1977-09-22

154

Simulation study of feedback systems based on a two-tap FIR filter. Under beam-beam collisions  

Energy Technology Data Exchange (ETDEWEB)

The performance of bunch-feedback systems based on two-tap FIR filters is discussed, particularly for transverse cases. Since they are the simplest type of FIR digital filters, the two-tap FIR filters should be suited to systems that require a very fast processing speed. However, in these feedback systems, a bunch must turn along a ring several times from the position-measurement to feedback kicking. Within these turns, irregular phase-jumps in the betatron motion can occur, due to several causes, such as the wake forces and beam-beam force. The discussion given in this paper is focussed on the effect of beam-beam collisions on these feedback systems. Based on linear theory and simulation studies, it has been found that these feedback systems can work with good performance, even under the influence of a strong beam-beam force. (author)

1998-04-01

155

Multiple glomus tumours: successful treatment with electron beam irradiation  

Energy Technology Data Exchange (ETDEWEB)

A case is reported of a 23-year old male with multiple glomus tumours that showed marked involution after he had electron beam therapy. (author).

1990-11-01

156

LIONEL V. BALDWIN  

Science.gov (United States)

Aug. 24, 1965. L. V. BALDWIN ETAL. 3202915. PARTICLE BEAM MEASUREMENT APPARATUS USING BEAM KINETIC. ENERGY TO CHANGE TIIE HEAT SENSITIVE RESISTANCE OF ...

157

Focused ion beam (FIB) milling of electrically insulating specimens using simultaneous primary electron and ion beam irradiation  

International Nuclear Information System (INIS)

There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging ...

2007-02-07

158

First ion beam transfered from the SPS to the LHC  

CERN Multimedia

An ion beam has been successfully transfered from the SPS to the LHC for the first time on 12 November 2007.

2007-01-01

159

Feed-forward compensation for transient beam loading of the 805 MHz debuncher for the Fermilab linac upgrade  

CERN Document Server

Feed-forward compensation for transient beam loading of the 805 MHz debuncher for the Fermilab linac upgrade

1990-01-01

160

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

161

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

162

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

163

A beam funnelling demonstration: Experiment and simulation  

Energy Technology Data Exchange (ETDEWEB)

Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the experiment will be presented ...

1990-01-01

164

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at low photon energies ...

1987-01-01

165

Effect of surface-perturbed intermolecular interaction on adsorption of simple gases on a graphitized carbon surface.  

Science.gov (United States)

In this paper, we investigate the effect of the solid surface on the fluid-fluid intermolecular potential energy. This modified fluid-fluid interaction energy due to the inducement of a solid surface is used in the grand canonical Monte Carlo (GCMC) simulation of various noble gases, nitrogen, and methane on graphitized thermal carbon black. This effect is such that the effective interaction potential energy between two particles close to surface is less than the potential energy if the solid substrate is not present. With this modification the GCMC simulation results agree extremely well with the experimental data over a wide range of pressures while the simulation results with the unmodified potential energy give rise to a shoulder near the neighborhood of monolayer coverage and the significant overprediction of the second and higher layer coverages. In particular the unmodified GCMC results exhibit very sharp change in those higher layers while the experimental data have a much ...

2004-08-31

166

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...

1995-12-31

167

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. ...

1976-06-13

168

Clinical application of stable xenon CT-CBF studies without denitrogenation  

Energy Technology Data Exchange (ETDEWEB)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient ({lambda}) using the inhalation of stable xenon (Xe{sup s}) and computed tomographic (CT) scanning are described. Thirty percent Xe{sup s} in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe{sup s} concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A{sub e} = 0.75A{sub a} + 2.15, K{sub e} = 0.67K{sub a} + 0.69; 21-40 years, A{sub e} = 0.56A{sub a} + 3.24, K{sub e} = 0.38K{sub a} + 1.12; 41-60 years, A{sub ...

1990-08-01

169

Clinical application of stable xenon CT-CBF studies without denitrogenation  

International Nuclear Information System (INIS)

Noninvasive and simplified methods for estimating regional cerebral blood flow (CBF) and regional partition coefficient (#lambda#) using the inhalation of stable xenon (Xe"s) and computed tomographic (CT) scanning are described. Thirty percent Xe"s in 70% oxygen was inhaled for 240 seconds and exhaled for 160 seconds during serial CT scanning without denitrogenation in 26 patients with cerebrovascular diseases and four volunteer controls. During the investigation, the end-tidal Xe"s concentration was continuously monitored with a thermoconductivity analyzer to determine the build-up range (A value) and build-up rate constant (K value) of the artery by the curve fitting method. Calculated A and K values were corrected by the following formulae reported previously: for patients aged 0-20 years, A_e = 0.75A_a + 2.15, K_e = 0.67K_a + 0.69; 21-40 years, A_e = 0.56A_a + 3.24, K_e = 0.38K_a + 1.12; 41-60 years, A_e = 0.91A_a + 1.95, K_e = 0.38K_a + 1.32; over 61 years, ...

170

The NuMI proton beam at Fermilab successes and challenges  

Energy Technology Data Exchange (ETDEWEB)

The NuMI beam at Fermilab has delivered over 5 x 10{sup 20} 120 GeV protons to the neutrino production target since the start for MINOS [1] neutrino oscillation experiment operation in 2005. We report on proton beam commissioning and operation status, including successes and challenges with this beam.

2008-11-01

171

State of macroparticles in the plasma of beam-plasma discharge  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

172

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

174

PBG structures for multi-beam devices  

International Nuclear Information System (INIS)

Photonic band gap structures with single or multiple defects show potential for use in single-beam and multi-beam klystrons and particle accelerators. The primary concerns are the coupling between the modes at each individual defect site and the damping of unwanted higher order modes. A conceptual design of a PBG based, multi-beam klystron and methods to damp HOMs and to cool and tune the structure are presented.

2002-12-12

175

Nuclear physics with a free electron laser  

International Nuclear Information System (INIS)

... radiation parity photonuclear reactions polarized beams resonance

181

Even Better Mousetraps  

CERN Document Server

First test with new ASACUSA trap show promise for future antihydrogen beam experiments.

2007-01-01

182

Emittance Limitation of a Conditioned Beam in a Strong Focusing FEL Undulator  

Energy Technology Data Exchange (ETDEWEB)

Various methods have been proposed to condition an electron beam in order to reduce its emittance effect and to improve the short-wavelength free electron laser (FEL) performance. In this paper, we show that beam conditioning does not result in a complete elimination of the emittance effect in an alternating-gradient focusing FEL undulator. Using a one-dimensional model and a three-dimensional simulation code, we derive a criteria for the emittance limitation of a perfectly conditioned beam that depends on the focusing structure.

2006-03-24

183

Electrostatic simulation of the modulated electron beam interaction with inhomogeneous plasma  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

184

Electromagnetic effects in relativistic electron beam plasma interactions  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic effects excited by intense relativistic electron beams in plasmas are investigated using a two-dimensional particle code. The simulations with dense beams show large magnetic fields excited by the Weibel instability as well as sizeable electromagnetic radiation over a significant range of frequencies. The possible relevance of beam plasma instabilities to the laser acceleration of particles is briefly discussed. 6 refs., 4 figs.

1985-02-13

186

Digital signal processing for beam position feedback  

Energy Technology Data Exchange (ETDEWEB)

Stabilization of the particle beam position with respect to the focusing optics in the third generation synchrotron light sources is crucial to achieving low emittance and high brightness. For this purpose, global and local beam orbit correction feedbacks will be implemented in the APS storage ring. In this article, the authors discuss application of digital signal processing to particle/photon beam position feedback using the PID (proportional, integral, and derivative) control algorithm.

1992-04-01

187

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

189

Beam instability of surface waves in cylindrical plasma waveguide  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

191

Operation experience with the 3 MW TRIGA Mark-II research reactor of Bangladesh  

International Nuclear Information System (INIS)

The 3 MW TRIGA Mark-II research reactor of Bangladesh Atomic Energy Commission (BAEC) has been operating since September 14, 1986. The reactor is used for radioisotope production ("1"3"1I, "9"9"mTc, "4"6Sc), various R and D activities and manpower training. The reactor has been operated successfully since it's commissioning with the exception of a few reportable incidents. Of these, the decay tank leakage incident of 1997 is considered to be the most significant one. As a result of this incident, reactor operation at full power under forced-convection mode remained suspended for about 4 years. During that time, the reactor was operated at a power level of 250 kW so as to carry out experiments that require lower neutron flux. This was made possible by establishing a temporary by pass connection across the decay tank using local technology. The other incident was the contamination of the Dry Central Thimble (DCT) that took place in March 2002 when a pyrex vial ...

2004-09-15

192

The propagation of relativistic heavy ions in multielement beam lines.  

Science.gov (United States)

We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionization chambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for arbitrary beam ...

193

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion ...

1994-01-01

194

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion ...

1994-01-01

195

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion beams ...

1993-12-01

196

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron ...

197

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of ...

2002-06-01

198

Dependence of proton beam polarization on ion source transition configurations  

Energy Technology Data Exchange (ETDEWEB)

The polarization of extracted SATURNE II proton beam as a function of different ion source configurations was studied. Two distinct experiments were necessary for this purpose. In the first one, the left-right instrumental asymmetry of the beam polarimeter was determined using an unpolarized beam. In the second one this correction factor was applied to asymmetries measured with the beam from the polarized ion source in all polarization states. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp-elastic scattering analyzing power is near its maximum. The results confirmed that the two so-called ``unpolarized states`` of the source were polarized to several percent, whereas the absolute values of the beam polarizations in the so-called ``polarized states`` were equal and opposite. It was observed that the hexapole lens of the ...

1997-11-11

199

Buffeting of a slender circular beam in axial turbulent flows  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the buffeting of a slender, circular, flexible beam-rod in an axial turbulent flow. The principal excitation mechanisms are the turbulent wall pressure fluctuations and the motion-dependent (self-excited) aerodynamic force caused by the beam motion. On the assumption that the turbulent wall pressure fluctuations are independent of the beam motion, a linear forced-vibration model is used to determine the buffeting response of the beam and to investigate the length scale effects of turbulences on the beam buffeting. Transverse buffeting of the beam in an axial turbulent flow depends largely on the ratio of the longitudinal scale of the turbulences to the bending wavelength of the beam and on the ratio of the circumferential scale of the turbulences to the radius of the beam. The spectra and the mean ...

1984-05-01

200

Possible observation of the coexistence of superconductivity and long-range magnetic order in NdRh_4B_4  

International Nuclear Information System (INIS)

The ternary rare earth compound NdRh_4B_4 has been studied by means of critical field, low temperature heat capacity, and static magnetic susceptibility measurements. Features in the upper critical field and heat capacity data at 1.31 K and 0.89 K suggest the occurrence of long-range magnetic order in the superconducting state. The temperature dependence of the static magnetic susceptibility follows a Curie-Weiss law with an effective magnetic moment #mu#sub(eff) = 3.58 +- 0.05 #mu#sub(B) and a Curie-Weiss temperature thetasub(p) = -6.2 +- 1.0 K between 20 K and room temperature. However, magnetization vs. applied magnetic field isotherms suggest the development of a ferromagnetic component in the Nd"3"+ magnetization at low temperatures. (author).

1979-01-01

201

On Low Energy Levels in 185W  

International Nuclear Information System (INIS)

Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)

1996-03-04

202

Media Choice in Environmental Information Dissemination for Solid Waste Management among Policy Formulators and Implementors: A Case Study of Oyo State, Nigeria  

British Library Electronic Table of Contents (United Kingdom)

Environmental information has been described as central to the issues of solid waste management and disposal. This study investigated the availability and accessibility of environmental information to the solid waste policy formulators and implementors with regard to the media/channels used for disseminating environmental information to the public. A descriptive survey design was adopted for the study. A purposive sampling technique was used to select the sample and the method produced 205 respondents that consisted of 185 Policy Implementors and 20 Policy Formulators. A total of 147 cases were finally analyzed, which included 16 Policy Formulators (80% of total sample) and 131 Policy Implementors (71% of total sample). Data collected were analyzed using descriptive statistics such as perc...

2009-01-01

203

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

204

IBM-2 calculation of band mixing in "1"3"2Ba  

International Nuclear Information System (INIS)

The band crossing in "1"3"2Ba has been investigated by using the interacting boson model. A broken neutron pair has been coupled to a collective boson core. The boson-fermion interaction hamiltonian contains terms which can transform a boson into a pair of quasiparticles and vice versa. The parameters were partly determined by fitting the collective states of "1"3"2","1"3"4Ba and the yrast states of "1"3"1Ba. The energy backbending has been satisfactorily reproduced. Good agreement of the electromagnetic moments has been reached. The structure of the wave functions has been discussed. (author)

1999-12-04

205

Heat transfer augmentation in liquid metal reactor steam generators  

International Nuclear Information System (INIS)

The use of heat transfer augmentation devices has been proposed as a means for reducing the cost of steam generators for advanced LMR designs by approximately 25%. Experimental results are presented for two types of enhancers in the form of a twisted-tape and a core-tube insert in the steam tube of a 13.1-m-long, sodium-heated single-tube test section. Test parameters were prototypical of liquid metal reactor (LMR) steam generator design for a once-through high-pressure steam cycle. Heat transfer results are compared with the no-insert case on an overall and local basis. Although both augmentations increased overall performance, the mechanisms were different.

206

Experimental parameterization of an energy function for the simulation of unfolded proteins  

DEFF Research Database (Denmark)

The determination of conformational preferences in unfolded and disordered proteins is an important challenge in structural biology. We here describe an algorithm to optimize energy functions for the simulation of unfolded proteins. The procedure is based on the maximum likelihood principle and employs a fast and efficient gradient descent method to find the set of parameters of the energy function that best explain the experimental data. We first validate the method by using synthetic reference data, and subsequently apply the algorithms to data from nuclear magnetic resonance spin-labeling experiments on the Delta 131 Delta fragment of Staphylococcal nuclease. A significant strength of the procedure that we present is that it directly uses experimental data to optimize the energy parameters, without relying on the availability of high resolution structures. The procedure is fully general and can be applied to a range of experimental data and energy functions ...

2008-01-01

207

Evaluation of quality of alkylsalicylate additives with high content of active substance  

Energy Technology Data Exchange (ETDEWEB)

This article describes the chemical preparation of petroleum additives of the MASK type from samples of concentrated alkylsalicylic acids. The obtained additives contain high contents of calcium alkylsalicylate and respective total alkalinities of 156, 131, and 130 mg KOH/g. Sodium alkylsalicylate concentrates, obtained in the form of an aqueous acetone solution, were converted to alkylsalicylic acids by interaction with hydrochloric acid. The solvent was removed from the upper and lower layers by distillation, and the resulting products were analyzed by liquid chromatography. Service tests were performed on a model formulation of the additive in M-11 oil in a Petter AV-1 test stand unit in comparison with commercial MASK additive. The results indicate that the model additive formulation gives approximately the same corrected piston fouling ratings as the commercial additive.

1984-09-01

208

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

209

The 0.9 MW proton beam at PSI and studies on a 10 MW cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design for a cyclotron that could possibly deliver a 10 MW proton beam, presented at the previous ADTT conference, is discussed in comparison with the operational experience gained with 0.9 MW beam power in the upgraded cyclotron facility at PSI that has reached the design goal of 1.5 mA at 590 MeV in 1995. Some critical aspects of the design are e.g. RF power and beam loading, beam loss and activation, space charge effects and bunching. 12 refs., 2 figs., 1 tab.

1997-09-01

210

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

211

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

Energy Technology Data Exchange (ETDEWEB)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

1986-10-01

212

Polarizing a stored proton beam by spin flip?  

International Nuclear Information System (INIS)

We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.

2009-04-27

213

Plasma production and flow in negative ion beams  

Science.gov (United States)

Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.

1977-09-21

214

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

215

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

216

Beam lifetime and emittance growth in RHIC under normal operating conditions with the hydrogen gas jet, the cluster-jet and pellet targets  

International Nuclear Information System (INIS)

The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the 'vacuum capture'.

2010-09-01

217

Beam Beam Simulation Studies for NLC And SLC2000  

Energy Technology Data Exchange (ETDEWEB)

We apply and modify the computer codes CAIN(P.Chen, G.Horton-Smith, T.Ohgaki, A.W.Weidemann, K.Yokoya, contributed to Workshop on Gamma-Gamma Colliders, Berkeley, CA, March 28-31, 1994; SLAC-PUB-6583.) and GUINEAPIG(D.Schulte (DESY), unpublished.) to make detailed studies of the beam-beam interaction in the SLAC design for a future linear collider (NLC), as well as to the proposed SLC2000 project. Using realistic beam distributions, we present simulations related to the tuning and optimization of luminosity in SLC2000 and NLC.

2010-05-27

218

Beam Beam Simulation Studies for NLC And SLC2000  

International Nuclear Information System (INIS)

We apply and modify the computer codes CAIN(P.Chen, G.Horton-Smith, T.Ohgaki, A.W.Weidemann, K.Yokoya, contributed to Workshop on Gamma-Gamma Colliders, Berkeley, CA, March 28-31, 1994; SLAC-PUB-6583.) and GUINEAPIG(D.Schulte (DESY), unpublished.) to make detailed studies of the beam-beam interaction in the SLAC design for a future linear collider (NLC), as well as to the proposed SLC2000 project. Using realistic beam distributions, we present simulations related to the tuning and optimization of luminosity in SLC2000 and NLC.

1997-05-12

219

Analysis of Longitudinal Space Charge Effects With Radial Dependence  

Energy Technology Data Exchange (ETDEWEB)

Longitudinal space charge (LSC) force can be a main effect driving the microbunching instability in the linac for an x-ray free-electron laser (FEL). In this paper, the LSC-induced beam modulation is studied using an integral equation approach that takes into account the transverse (radial) variation of LSC field for both the coasting beam limit and bunched beam. Changes of beam energy and the transverse beam size can be also incorporated. We discuss the validity of this approach and compare it with other analyses as well as numerical simulations.

2005-09-30

220

Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument  

International Nuclear Information System (INIS)

Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ ...

2008-08-01

221

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear ...

1998-08-01

222

Design study of longitudinal dynamics of the drive beam in 1 TeV relativistic klystron two-beam accelerator  

International Nuclear Information System (INIS)

In this paper the authors present a design study on the longitudinal dynamics of a relativistic klystron two-beam accelerator (RK-TBA) scheme which has been proposed as a power source candidate for a 1 TeV next linear collider (NLC). They address the issue of maintaining stable power output at desired level for a 300-m long TBA with 150 extraction cavities and present their simulation results to demonstrate that it can be achieved by inductively detuning the extraction cavities to counter the space charge debunching effect on the drive beam. They then carry out simulation study to show that the beam bunches desired by the RK-TBA can be efficiently obtained by first chopping an initially uniform beam of low energy into a train of beam bunches with modest longitudinal dimension and then using the open-quotes adiabatic captureclose quotes scheme to bunch and accelerate these ...

1994-11-07

223

Beam stabilization in SPring-8 linac for top-up injections into storage rings  

International Nuclear Information System (INIS)

The SPring-8 linac has been improved to realize stable top-up injection into the SPring-8 and the NewSUBARU storage rings. The beam energy instability of 0.02% rms in the long term was achieved by means of reducing RF variations, providing beam energy compensation, reinforcement of monitor systems and introduction of beam feedback controls: Variations in the RF power and phase have been reduced by improving the voltage regulation system for the klystron modulator, and by stabilizing the temperature drift of the atmosphere and cooling water in order to reduce the phase variation. A new synchronous oscillator synchronizes a beam trigger pulse and a 2856 MHz reference signal, reducing variation in the beam charge. A beam energy compression system (ECS) was installed to compensate for accidental energy variation and reduce the energy spread. ...

2006-03-01

224

Steering of high energy negative ion beam and design of beam focusing/deflection compensation for JT-60U large negative ion source  

Energy Technology Data Exchange (ETDEWEB)

A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator ...

2000-03-01

225

A high-power millimeter-wave sheet beam free-electron laser amplifier  

International Nuclear Information System (INIS)

The results of experiments with a short period (9.6 mm) wiggler sheet electron beam (1.0 mm x 2.0 cm) millimeter-wave free electron laser (FEL) amplifier are presented. This FEL amplifier utilized a strong wiggler field for sheet beam confinement in the narrow beam dimension and an offset-pole side-focusing technique for the wide dimension beam confinement. The beam analysis herein includes finite emittance and space-charge effects. High-current beam propagation was achieved as a result of extensive analytical studies and experimental optimization. A design optimization resulted in a low sensitivity to structure errors and beam velocity spread, as well as a low required beam energy. A maximum gain of 24 dB was achieved with a 1-kW injected signal power at 86 GHz, a 450-kV beam voltage, 17-A ...

226

The operation status and prospect of radioisotope production facility in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power supply and distribution system, UPS, fire protection system, liquid radioactive ...

2008-11-15

227

Technology of iodine-131 production and its application  

International Nuclear Information System (INIS)

Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to measure the ...

228

Role of nuclear structure on the tilting mode  

Energy Technology Data Exchange (ETDEWEB)

The high spin fraction (HSF) of {sup 131}Te as a function of fragment emission angle has been determined in the 40 MeV alpha-particle induced fission of {sup 238}U using off-line gamma ray spectrometric technique. From the HSF the fragment average spin (J{sub av}) of fission product has been deduced using statistical model analysis. The J{sub av} value of {sup 131}Te is seen to remain nearly constant (10{Dirac_h}) from 90 deg. to 20 deg. On the other hand, the J{sub av} value of {sup 132}I from earlier work shows a drastic decrease (33%) from 11.4{Dirac_h} at 90 deg. to 7.6{Dirac_h} at 20 deg. . However, the yield weighted J{sub av} value of both the products show a decrease of 13%, which in close agreement with the value of 5-10% change from 90 deg. to 0 deg. in the results obtained from gamma ray multiplicity measurements. Thus the drastic difference in the change of fragment average spin (J{sub av}) of individual product from 90 deg. to 20 ...

2003-12-11

229

In vitro and in vivo activities of T4 endonuclease V mutants altered in the C-terminal aromatic region  

International Nuclear Information System (INIS)

Genes encoding mutants of the thymine photodimer repair enzyme from bacteriophage T4 (T4 endonuclease V) having an amino acid substitution (T127M, W128A, W128S, Y129A, K130L, Y131A, Y132A) were constructed by use of a previously obtained synthetic gene and expressed in Escherichia coli under the control of the E. coli tryptophan promoter. An in vitro assay of partially fractionated mutant proteins for glycosylase activity was performed with chemically synthesized substrates containing a thymine photodimer. T127M and K130L showed almost the same activity as the wild-type protein. Although W128S, Y131A, and Y132A were slightly active, W128A and Y129A lost activity. The results indicated that the aromatic amino acids around position 130 may be important for the glycosylase activity. Mutant T127M was purified, and the Km value was found to be of the same order as that of the wild type (10(-8) M). In vivo activities for all mutants were ...

230

Impact assessment using 25 years of environmental radioactivity monitoring data at Tarapur Maharashtra site  

International Nuclear Information System (INIS)

Environmental Survey Laboratory at Tarapur, Maharashtra site carries out environmental radioactivity measurements in different matrices to evaluate the impact of operating nuclear installations. In this paper, the evaluation of data of 1983-2007 (25 years) is presented. Time trends of particulate radioactivity, correlation between "1"3"7Cs in discharge canal seawater and station discharged activity and correlation of "1"3"7Cs, "6"0Co, and "1"3"1I in marine species like Sponge and Nerita and corresponding discharged activity were carried out. Statistical analysis of environmental data of seawater and marine fish for several radionuclides, for distributions, showed that the data best fits lognormal distribution. A strong correlation between "1"3"7Cs in seawater and "1"3"7Cs in liquid waste discharge was observed (R"2 = 0.8, P = 0.000). Similarly correlation was very good for Nerita and discharged concentration for "1"3"7Cs, "1"3"1I and "6"0Co ...

2008-07-16

231

Effective equivalent dose and radiation risk in radionuclide diagnostics estimated in patients of the Nuclear Medicine Department of the Medical Academy 'Carl Gustav Carus' Dresden  

International Nuclear Information System (INIS)

7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic risk 1.7 x 10"-"5 according to 0.11 malignomas. The average ...

1986-01-01

232

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

Energy Technology Data Exchange (ETDEWEB)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted ...

1992-04-01

233

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

International Nuclear Information System (INIS)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...

1992-01-01

234

Analysis of delta-ferrite data from production stainless steel pipe welds  

Science.gov (United States)

An American Society of Mechanical Engineers task group on stainless steel weld materials was organized to determine the need for ferrite measurements of production welds required by the US Nuclear Regulatory Commission Regulatory Guide 1.31 (Rev. 1). The task group studied paired ferrite measurements (i.e., calculated and measured ferrite numbers (FNs) for the material qualifications versus measured ferrite numbers for corresponding production welds (PWs)). Our purpose was to compare delta-ferrite content as measured in the filler metal weld qualification pad with that in the resultant PW. Welds made predominantly by three common processes (submerged arc, shielded metal arc, and gas tungsten arc) were included in the study. Weld metals investigated included types 308, 308L, 316, and 316L stainless steel. An initial evaluation of the paired ferrite measurements was made by the task group, and specific conclusions and recommendations were made. We describe the ...

1984-01-01

235

Simplification of Finite Element Models for Structures Having a Beam-Like Behaviour  

Science.gov (United States)

A method for simplifying finite element models of structures having a beam-like global dynamical behaviour is presented. This method is based on the use of a general uniform beam finite element formulation. It takes into account both transverse shear effects and dynamical coupling between bending and torsion due to the fact that mass centres and shear centres do not always coincide. For that purpose, we develop a condensation method for reducing any shell model into an equivalent beam, as well as a technique for automatically identifying the corresponding set of beam parameters. The method is applied to several illustrate examples that demonstrate its ability to simplify finite element models for many kinds of sophisticated structures having a beam-like predominant behaviour.

2000-04-01

236

Resurrection of beam conditioning for free electron lasers  

Energy Technology Data Exchange (ETDEWEB)

Recently Emma and Stupakov identified a fatal flaw in a Free Electron Laser (FEL) beam conditioning scheme. They showed that the conditioning is always accompanied by a projected transverse emittance growth that is so large as to make the beam conditioning completely impractical for short wavelength FELs. Furthermore, they provided a general proof along with evidence of computer simulation and reached a conclusion that any beam conditioner, regardless of the method, would suffer from the same constraints and limitations. In this paper, the author proposes an easy surgical removal of the fatal flaw by making a critical yet simple modification to the very scheme analyzed, thus resurrect the beam conditioning for short wavelength FELs. More generally, the also explain why a general search for removing have failed, why the concept and definition of beam conditioning.

2003-02-17

237

Minimal Neutrino Beta Beam for Large theta_13  

CERN Document Server

We discuss the minimum requirements for a neutrino beta beam if theta_13 is discovered by an upcoming reactor experiment, such as Double Chooz or Daya Bay. We require that both neutrino mass hierarchy and leptonic CP violation can be measured to competitive precisions with a single-baseline experiment in the entire remaining theta_13 range. We find that for very high isotope production rates, such as they might be possible using a production ring, a (B,Li) beta beam with a gamma as low as 60 could already be sufficient to perform all of these measurements. If only the often used nominal source luminosities can be achieved, for example, a (Ne,He) beta beam from Fermilab to a possibly existing water Cherenkov detector at Homestake with gamma \\sim 190-350 (depending on the Double Chooz best-fit) could outperform practically any other beam technology including wide-band beam and ...

2008-01-01

238

Joint shear strength of FRP reinforced concrete beam-column joints  

British Library Electronic Table of Contents (United Kingdom)

An assessment of the joint shear strength of exterior concrete beam-column joints reinforced internally with Glass Fibre Reinforced Polymer (GFRP) reinforcements under monotonically increasing load on beams keeping constant load on columns is carried out in this study. Totally eighteen numbers of specimens are cast and tested for different parametric conditions like beam longitudinal reinforcement ratio, concrete strength, column reinforcement ratio, joint aspect ratio and influence of the joint stirrups at the joint. Also finite element analysis is performed to simulate the behaviour of the beam-column joints under various parametric conditions. Based on this study, a modified design equation is proposed for assessing the joint shear strength of the GFRP reinforced beam-column specimens b...

2011-01-01

239

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

240

Drift-kink instability induced by beam ions in field-reversed configurations  

Energy Technology Data Exchange (ETDEWEB)

The drift-kink instability in field-reversed configurations with a beam component is investigated by means of a three-dimensional particle simulation. The unstable mode with the toroidal mode number n=4 grows with the rate {gamma} {approx} 0.1 - 1.0{omega}{sub ci} for a strong beam current and deforms the plasma profile along the beam orbit in the vicinity of the field-null line. This mode is nonlinearly saturated as a result of the relaxation of current profile. Both the saturation level and the growth rate tend to increase as the ratio of the beam current to the plasma current I{sub b}/I{sub p} increases. It is also found that there is a threshold value of the beam velocity {upsilon}{sub b} {approx} {upsilon}{sub Ti} (ion thermal velocity) for the excitation of the instability. (author)

1999-04-01

241

An integrated high-performance beam optics-nuclear processes framework with hybrid transfer map-Monte Carlo particle transport and optimization  

International Nuclear Information System (INIS)

An integrated beam optics-nuclear processes framework is essential for accurate simulation of fragment separator beam dynamics. The code COSY INFINITY provides powerful differential algebraic methods for modeling and beam dynamics simulations in absence of beam-material interactions. However, these interactions are key for accurately simulating the dynamics of heavy ion fragmentation and fission. We have developed an extended version of the code that includes these interactions, and a set of new tools that allow efficient and accurate particle transport: by transfer map in vacuum and by Monte Carlo methods in materials. The new framework is presented, along with several examples from a preliminary layout of a fragment separator for a facility for rare isotope beams.

2010-12-01

242

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the ...

1999-05-01

243

Theory of low voltage annular beam free-electron lasers  

Energy Technology Data Exchange (ETDEWEB)

An nonlinear analysis of an annular beam propagating through a cylindrical waveguide in the presence of a helical wiggler and an axial guide field is presented. The analysis is based upon the ARACHNE simulation which is a non-wiggler-averaged slow-time-scale simulation code in which the electromagnetic field is represented as a superposition of the TE and TM modes in a vacuum waveguide, and the beam space-charge waves are represented as a superposition of Gould-Trivelpiece modes. The DC self-electric and self-magnetic fields are also included in the model. ARACHNE has been extensively benchmarked against experiments at MIT and NRL in the past with good agreement, but all of these experiments have dealt with solid electron beams and beam voltages in excess of 200 kV. In seeking to reduce the beam voltage requirements we now consider the effect of operation with an annular ...

1995-12-31

244

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A were produced at 340 keV ...

2008-02-01

245

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of ...

2008-07-01

246

Wrinkled hard skins on polymers created by focused ion beam  

UK PubMed Central (United Kingdom)

A stiff skin forms on surface areas of a flat polydimethylsiloxane (PDMS) upon exposure to focused ion beam (FIB) leading to ordered surface wrinkles. By controlling the FIB fluence and area of exposure...Full Text Available

2007-01-23

247

Simulation of electron beam therapy employing cone collimation  

Energy Technology Data Exchange (ETDEWEB)

A simple device is described which is used to determine treatment distance and beam direction in electron therapy employing one collimation. A technique for the production of irregular field templates and localization films is given.

1983-07-01

248

Residual Stresses in Ta, Mo, Al and Pd Thin Films Deposited by E-Beam Evaporation Process on Si and Si/SiO 2 Substrates  

CERN Document Server

Residual Stresses in Ta, Mo, Al and Pd Thin Films Deposited by E-Beam Evaporation Process on Si and Si/SiO 2 Substrates

2006-01-01

249

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

250

Real-time neutron beam monitor  

Energy Technology Data Exchange (ETDEWEB)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.

1983-06-15

251

Protons, heavy ions, radioactive beams: new ways for radiotherapy. Protons, ions lourds, faisceaux radioactifs: de nouvelles voies pour la radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the principles, applications and advantages of proton and heavy ion beams used for radiotherapy.

1993-07-01

252

Progress report on negative ion beams based on User Development Workshop on negative ion based neutral beams, 15-16 February, 1983, Princeton  

International Nuclear Information System (INIS)

Progress in the development of negative ion sources and their application in fusion research is reviewed. (U.K.).

1983-04-18

253

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

254

Low-energy measurements of electron capture by multicharged ions from excited hydrogen atoms  

International Nuclear Information System (INIS)

For very low collision energies electron capture from excited hydrogen by multicharged ions is characterized by enormous cross sections, the predicted maximum being comparable to the geometric size of the Rydberg atom. The ion-atom merged-beams technique is being used to study these collisions for the variety of charge states and the wide range of energies (0.1 to 1000 eV/amu) accessible to the apparatus. A neutral D beam containing a Rydberg atom population proportional to 1/n"3 is produced by collisional electron detachment of 8 keV D"- in N_2 gas. An applied electric field results in the range (n=24--11) depending on the strength of the field applied. This beam is then merged with O"3"+ or O"5"+ ion beams at low relative collision velocities where the resultant beam-beam signal of D"+ due to electron loss is dominated by electron capture. From the sharp decrease in the observed ...

255

Ion sources for initial use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization ...

1994-12-31

256

Ion sources for initial use at the Holifield Radioactive Ion Beam Facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the HRIBF because of its low emittance, relatively high ionization ...

1994-05-01

257

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

258

Intraoperative and external beam irradiation for locally advanced colorectal cancer.  

UK PubMed Central (United Kingdom)

In view of poor local control rates obtained with standard treatment, intraoperative radiation (IORT) using electrons was combined with external beam irradiation and surgical resection, with or without...Full Text Available

1988-01-01

259

High intensity inverted sputter source  

Energy Technology Data Exchange (ETDEWEB)

The electrode structure of an inverted cesium sputtering negative ion source has been modified to produce a convergent Cs/sup +/ beam. The intensities of negative ion beams produced with this electrode structure are approximately an order of magnitude greater than previously obtained.

1982-08-15

260

Feature-based rectal contour propagation from planning CT to cone beam CT  

UK PubMed Central (United Kingdom)

The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available

2008-10-01

261

Evaluation of tilted cone-beam CT orbits in the development of a dedicated hybrid mammotomograph  

UK PubMed Central (United Kingdom)

A compact dedicated 3D breast SPECT-CT (mammotomography) system is currently under development. In its initial prototype, the cone-beam CT sub-system is restricted to a fixed-tilt circular rotation...Full Text Available

2009-06-21

262

Doublet III vacuum vessel neutral beam armor  

Science.gov (United States)

The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.

1979-11-01

263

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to ...

1988-07-01

264

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce ...

1988-01-01

265

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion ...

2003-05-01

266

Comparison of beam-induced deposition using ion microprobe  

International Nuclear Information System (INIS)

The localized Pt deposition on Si by 30 keV Ga"+ focused ion beam (FIB), 10 keV electron beam (EB) or dual beams (FIB and EB) using precursor gas has been compared by analysis using a 300 keV Be"2"+ microprobe with a beam spot size of 80 nm. The distribution of deposited Pt, Ga from the ion beam itself, and C from the precursor gas was obtained at and nearby the deposited areas by micro-RBS spectra and RBS mapping. All of the beam processed areas showed a uniform Pt distribution at the deposited areas. The amount of Pt atoms increased with the increase in ion or electron dose due to the decomposition of precursor gas. The thickness of Pt layer by EB is considerably less than that by FIB due to the reduced deposition rate. Ga atoms from the center of processed areas partly redeposited at and nearby the FIB processed areas within #approx#3 #mu#m. The Ga ...

1999-01-02

267

Beam-breakup calculations for the Los Alamos free-electron laser (FEL) linac  

International Nuclear Information System (INIS)

In addition to the usual circularly symmetric TM/sub 010/ mode used to accelerate particles in an rf linac, there is a large number of modes with cos phi or sin phi dependence, for example the TM/sub 1xx/ modes. These latter modes possess a uniform magnetic (dipole) field near the axis of symmetry and therefore can deflect the beam away from the axis. Any portion of an accelerated beam that is off-axis will drive these modes, so that subsequent portions of the beam will be deflected. This deflected beam will then resonantly drive the same modes in downstream cavities, so that still later portions of the beam will be more severely deflected, and so on. In this paper are reported the results of numerical simulations of this so-called cumulative beam-breakup instability. The simulation assumes that only the TM/sub 110/ mode acts to deflect the ...

268

Beam collimator  

CERN Document Server

A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.

1977-01-01

269

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum ...

2008-09-01

270

A real-time neutron beam monitor  

International Nuclear Information System (INIS)

An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).

1983-06-01

271

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

272

"Spin" and "Orbital" Flows in a Circularly Polarized Paraxial Beam: Orbital Rotation without Orbital Angular Momentum  

CERN Document Server

In light beams with circular or elliptic polarization, the transverse energy flow consists of the "spin" and "orbital" parts. Both of them can induce the orbital motion of microparticles suspended within the field of a light beam, and this should be taken into account in experiments on the spin-to-orbital angular momentum conversion. The character of the spin, orbital and total transverse energy flows in circular Laguerre-Gaussian beams is studied analytically; graphical representations of the flows in the beam cross section (flow maps) are calculated and analyzed. The spin circulatory flow can be directed oppositely to the orbital one and/or to the polarization handedness. As a result, the total transverse energy circulation of a beam with homogeneous circular polarization can be of different handedness in different regions of the beam cross section, which are ...

2009-01-01

273

Works on the start-up of an infrared free-electron laser in FIAN  

International Nuclear Information System (INIS)

The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL

2000-10-17

274

Tolerance analysis of a phase space beam analyzer  

Science.gov (United States)

The phase space beam analyzer is a measurement instrument that is applied in laser technology to perform analyses of the spatial and angular distribution of rays. We are interested in this instrument as a means to characterize non-coherent light sources. In this context, a closer look at the tolerances of this optical instrument was considered useful. Having a so-called quadrupole lens as a key element, the phase space beam analyzer is a device that features anamorphic optical properties. To describe these anamorphic properties, recurrence was made to a description by extended ray-transfer matrices. This formalism allows for an analysis of the alignment tolerances of the phase space beam analyzer and facilitates a study of the sensitivities of the instrument. The analysis is complemented using numerical ray tracing.

2007-09-01

275

The preparation of carrier-free "2"0"3Pb for medical use  

International Nuclear Information System (INIS)

... bismuth 203 chemical reactions cyclotrons decay helium 3 beams impurities

276

Stability against temperature variations at the ALS  

Energy Technology Data Exchange (ETDEWEB)

We have studied the effects of temperature fluctuations on the Advanced Light Source (ALS). By modeling the storage ring support structure, we find that fluctuations of {plus minus}2 to 3deg C in the tunnel will cause photon beam motion of the order of the beam size. Temperature stabilization at this level will allow the residual motion of the photon beams to be reduced by a second level of active feedback, operating on signals from photon beam position monitors. Air temperature in the experimental area and the temperature of cooling water serving the beamlines should be constant to {plus minus}1deg C. This will provide a suitable environment for experiments. (orig.).

1990-05-20

277

Spectroscopy of "1"0"1Mo by sub-Coulomb stripping  

International Nuclear Information System (INIS)

... deuteron beams differential cross sections dwba excitation functions mev range

278

Species dependence of the emittances of sputter-generated negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum analysed /sup 28/Si/sup -/, /sup 58/Ni/sup -/ and /sup 197/Au/sup -/ ion beams generated by caesium ion sputtering. The high-resolution emittance measurement techniques employed in this work have enabled us to estimate the energy spreads of these ion beams; differences in the widths of the energy distributions are the origin of the observed differences in emittances of the ion beams investigated. (author).

1989-04-14

279

Spatial and angular characteristics of microsecond negative-ion beams in a magnetically insulated diode  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.

1995-10-01

280

Screening of Flexible Cables by Nonlinear Resistance ...  

Science.gov (United States)

... Abstract : Two traces in flexible cables used in the Milstar agile beam antenna system failed during acceptance testing. ...

1994-01-10

282

Power Beaming, Orbital Debris Removal, and Other Space ...  

Science.gov (United States)

... transition to couple the emitted spontaneous radiation with the ammonia molecules and thus provide more amplification [2]. ...

2010-03-01

283

Performance estimates of photoneutralized negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Recent studies have provided data that make it possible to estimate the efficiency and cost of future beamlines using a chemical oxygen-iodine laser as a neutralizer. These studies indicate that a 400-keV neutral deuterium beam of more than 20 A will operate at an efficiency >60%, with the capital cost of the neutralizer at less than $2/W of neutral beam output. Beamlines of lower current and less energy will operate at poorer efficiencies and higher neutralizer costs per watt of neutral beam. These are estimates. As they are very sensitive to changes in the assumptions from which they were derived, they must be used with some caution. Additional studies are expected to provide more reliable estimates.

1984-11-01

284

Neutron escape from isobaric analogue resonances  

International Nuclear Information System (INIS)

... level widths mev range 01-10 neutrons nuclear reactions proton beams

286

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

287

Improved, chirped acousto-optic q switch. [Patent application  

Science.gov (United States)

An improved acousto-optic laser Q-switch uses a chirped fm pulse in the acousto-optic cell to diffract and focus the input beam into a resonating high-Q mode. When the rf acoustic pulse is not wholly within the cell, the beam is diverted to the output. A reflective surface is placed on the cell to yield only one output beam and to yield a retroflective beam back into the cavity for a high Q condition whenever a correctly generated chirp acoustic wave is in the proper postion within the cell.

1977-01-24

288

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

291

Evaluation of Daytime Boundary Layer Heights from a ...  

Science.gov (United States)

... the vertical beam measures the movement of the ... be measured because the particle velocity in ... During precipitation, if the hydrometeor fall velocity is ...

2008-03-01

292

Emittance characteristics of negative ion beams generated by the sputter technique  

Energy Technology Data Exchange (ETDEWEB)

Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.

1990-01-01

293

Emittance characteristics of negative ion beams generated by the sputter technique  

Energy Technology Data Exchange (ETDEWEB)

Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.

1989-01-01

294

Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target  

Energy Technology Data Exchange (ETDEWEB)

Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

1980-09-01

295

Electron beam curable phenol-formaldehyde resin  

International Nuclear Information System (INIS)

The novolac type phenolic resins were synthesized and electron beam curing was carried out to the prepolymer obtained by the reaction of the phenolic resin and glycidyl meth acrylate in the presence of triethylbenzyl ammonium chloride. When the prepolymer and its mixtures with monomers were irradiated using electron beams at a dose rate of 3 Mrad/sec, the curing were completed at a dose 2.5 and 3 Mrad respectively. The effects of oxygen and that of hydroxyl group in the prepolymer on electron beam curing were also examined. (author).

296

ELECTRON ATTACHMENT OF SEF6  

Science.gov (United States)

... attachment tube which is sketched in Fig. 1. It is mounted inside a cylindrical evacuated tube. A beam of thermal electrons ...

1961-06-20

297

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

298

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

299

Challenges of Aircraft Design Integration  

Science.gov (United States)

... The program generates conceptual layouts of wing structural components and creates a beam finite element model of the wing structure (Figure 6 ...

2003-03-01

300

Analysis of the beam bunching produced by a free electron laser  

International Nuclear Information System (INIS)

A high-power microwave Free Electron Laser (FEL) experiment has been performed to study the inherent electron beam bunching that occurs in the FEL interaction. An induction linac delivered a 1 kA, 2.2 MeV electron beam to a FEL amplifier. In the process of amplifying the input signal of frequency 35 GHz to power levels of the order of 10 MW, the electron beam was bunched by the ponderomotive force. In this paper we describe the FEL experiment and the optical technique that was used to observe the bunches. Their properties as functions of the basic FEL parameters are discussed. copyright 1996 American Institute of Physics.

301

A new scheme of the longitudinal emittance measurement for negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).

1995-08-01

302

"2"0"3Pb yields while irradiating thallium with protons and deuterons  

International Nuclear Information System (INIS)

... data deuteron beams energy dependence errors gamma radiation lead 203

303

Transverse velocity modulator and generator schemes based on non-collinear radiation and electron beams  

International Nuclear Information System (INIS)

New non-collinear schemes are suggested for transverse velocity modulation of electron beams and for the generation of coherent spontaneous radiation by these transversely modulated beams. It is shown that due to the non-collinearity some orders of magnitude enhancement can be achieved for the coherent spontaneous radiation (CSR) power at both the fundamental and harmonic frequencies.

2000-05-01

304

The proton microprobe: Applications in the biomedical field  

Energy Technology Data Exchange (ETDEWEB)

This book explores the development, present, and future applications of proton microprobes in the micrometer range. Among the topics discussed: the use of proton beams for analytical purposes; techniques of focusing or collimating ion beams; improving and measuring beam spots; the analytical capabilities of the nuclear microprobe in comparison to other micro techniques; and applications and results by several internationally known microprobe laboratories.

1986-01-01

305

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.

1995-12-31

306

The physics of production, acceleration and neutralization of large negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).

1995-11-01

307

Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs  

International Nuclear Information System (INIS)

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer ...

2008-09-07

308

Proton beam therapy for cancer in deep-seated organs  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.

1988-10-01

309

Plasma lens formation in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).

1995-02-01

310

Photoexcitation and optical pumping in a barium atomic beam  

International Nuclear Information System (INIS)

An apparatus allowing the photoexcitation of barium atomic beam over its whole surface is described. This photoexcitation is achieved by another barium spectrum emitted up steam of the beam by a cathodic out-flow produced at the exit oven. The fluorescence spectrum is studied in detail as well as the influence of different parameters, such as oven temperature, current intensity of the outflow, and excitation depth. A calculation shows how to determine Einstein coefficient, oscillator strengths and atomic lifetimes from our experimental measurements.

311

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

312

LC-MS analysis in the e-beam and gamma radiolysis of metoprolol tartrate in aqueous solution: Structure elucidation and formation mechanism of radiolytic products  

British Library Electronic Table of Contents (United Kingdom)

E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.

2006-01-01

313

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

314

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton ...

2007-07-01

315

Development of neutral-beam injectors. Report on the third workshop, Gatlinburg, Tennessee, United States of America 19-23 October 1981  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on the third workshop on the development of neutral-beam injectors held from 19-23 October 1981 at Gatlinburg, Tennessee, USA. The programme of the workshop was devoted to the development of positive-ion-based neutral injectors, although several techniques for producing negative ion beams were also discussed.

1982-03-01

316

Development of laser-ion beam photodissociation methods  

Energy Technology Data Exchange (ETDEWEB)

During this report period our research efforts have concentrated on studies of the dissociation reactions of model peptides and other biologically important molecules. In addition, a considerable amount of research effort has been directed toward improving the apparatus used for laser-ion beam photodissociation. The instrumental improvements include some changes on the original apparatus, but most of this effort involved designing a second generation laser-ion beam photodissociation instrument.

1990-08-01

317

Crab crossing in a gamma-gamma collider  

International Nuclear Information System (INIS)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision.

1994-03-28

318

Crab crossing in a Gamma-Gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting {gamma}-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).

1995-02-01

319

Crab crossing in a Gamma-Gamma collider  

International Nuclear Information System (INIS)

The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).

320

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

321

Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report  

International Nuclear Information System (INIS)

The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.

322

CAIN: Conglomerat d`ABEL et d`Interactions Non-lineaires  

Energy Technology Data Exchange (ETDEWEB)

We present our plans for a Monte-Carlo code simulating all possible combinations of (electromagnetic) interactions between colliding electron, positron, and both high-energy and laser photon beams, based on the ABEL code for beam-beam interaction. The implementation and first results for the laser-e{sup -} interaction are described. ((orig.)).

1995-02-01

323

CAIN: Conglomerat d'ABEL et d'interactions non-lineaires  

International Nuclear Information System (INIS)

We present our plans for a Monte-Carlo code simulating all possible combinations of (electromagnetic) interactions between colliding electron, positron, and both high-energy and laser photon beams, based, on the ABEL code for beam-beam interaction. The implementation and first results for the laser-e"- interaction are described.

1994-03-28

324

Analysis of longitudinal bunching in an FEL driven two-beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Recent experiments have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here the authors present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, the authors examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.

2000-08-01

325

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

326

A photon beam position monitor for SSRL beamline 9  

Energy Technology Data Exchange (ETDEWEB)

We present here the concept of a simple one dimensional photon beam position monitor for use with high power synchrotron radiation beams. It has micron resolution, reasonable linearity in an inexpensive design. Most important, is its insensitivity to diffusely scattered low energy radiation from components upstream of the monitor.

1995-10-01

327

A magnetically insulated negative ion source for neutral beam heating  

Energy Technology Data Exchange (ETDEWEB)

A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.

1983-08-01

328

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

329

Relative luminosity measurement of the LHC with the ATLAS forward calorimeter  

CERN Document Server

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.

2010-01-01

330

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

331

R and D for the development of negative ion beams of halogens  

Energy Technology Data Exchange (ETDEWEB)

Ion beams of halogens can be produced either positively or negatively charged, depending on the employed ion source. At CERN-ISOLDE, although positively charged fluorine and astatine can be obtained from a hot plasma ion source, they are often contaminated by isobars and molecular sidebands. This has generated a request from the scientific community for fluorine and astatine negative ion beams free of contaminants. The high selectivity ensured by the surface ionisation process also makes negative beams of chlorine, bromine and iodine highly attractive. However, the efficiency figures for negative surface ionisation of fluorine and astatine were lower than the ones from the hot plasma. Here we report our R and D on new surface ion sources suitable for the production of negative halogen beams.

2008-10-15

332

Propagation of Surface Ripples on Pyrochlore Single Crystals Induced by Ion Beam Bombardment  

Energy Technology Data Exchange (ETDEWEB)

The morphological evolution of ripples formed on the surface of Cd2Nb2O7 pyrochlore single crystals by focused ion beam (FIB) bombardment was investigated using in situ electron microscopy. At high ion fluences and off-normal bombardment angles, faceted surface ripples with a terrace-like structure were observed. The ripple propagation direction was oriented along the projected ion beam direction at incident angles ranging from 35 to 65 following high-dose ion bombardment. One side of the terrace was found to be perpendicular to the incident ion beam direction, while the other side was parallel to the ion beam. The terrace propagation velocity and direction were determined and interpreted on the basis of this asymmetric structure. A model based on the propagation of a shock wave that effectively self-selects a stable slope, was developed in order to explain the observed faceted ripple formation.

2009-08-01

333

Pencil-like mm-size electron beams produced with linear inductive voltage adders  

International Nuclear Information System (INIS)

We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.

334

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-12-31

335

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-11-10

336

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

337

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.

1999-01-01

338

Focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.

1999-08-31

339

Focused ion beam preparation of inclined planes in semiconductor materials  

International Nuclear Information System (INIS)

Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).

340

Electron-beam sensitivity study of the Los Alamos Advanced Free-Electron Laser beam line  

Energy Technology Data Exchange (ETDEWEB)

A sensitivity study that used the particle tracking code PARMELA was performed on the Advanced Free-Electron Laser (AFEL). The tolerances on the alignment of the beam-line elements and the magnetic-field strengths were examined. Two base-line configurations were determined at the beginning of the study. The electron beam was then matched into the wiggler. The optimized beam-line parameters were varied independently and their sensitivities were judged with the criterion that the free-electron laser (FEL) effective-detuning parameter should not fluctuate more than 10%. The results of this study set the specifications for the alignment, for the sensitivity of the steering magnets, and for the accuracy of the magnetic field in the quadrupoles and dipoles. 5 figs., 3 figs., 3 tabs.

1991-01-01

341

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

342

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

343

Damping Ring to Interaction Point Beam Transport Issues  

CERN Document Server

One of the major challenges facing the proposed high-energy linear e^+e^ colliders is the preservation of the extremely small vertical emittance from the damping rings to the interaction point (IP). This emittance must be transported through bunch compression sections, the main linac and finally through the beam delivery system to the IP. Historically, the beam dynamics issues of each subsystem have been studied quasi-independently, with the beam conditions and tolerances being specified at the boundaries. As part of the recent International Linear Collider Technical Review Committee, new simulation tools have been developed to simulate the beam transport through the integrated system, including static and dynamic errors, stabilization systems, and tuning algorithms.

2003-01-01

344

Controlled manipulation of carbon nanopillars and cantilevers by focused ion beam  

International Nuclear Information System (INIS)

We explore a novel phenomenon of focused ion beam (FIB) induced bending of carbon nanopillars or cantilever structures. The bending occurs towards the ion beam during scanning. The explanation of this bending has been sought on the basis of a model which considers temperature rise and gradients caused by the impinging ion beam. The process is controllable and reversible, which makes it highly suitable for in situ manipulation to make desired 3D shapes by the piecewise bending of the nanopillars and cantilever structures during their fabrication using electron beam or FIB chemical vapor deposition (EB-CVD or FIB-CVD). Its usefulness in the fabrication of nanosize mechanical components has been demonstrated by making a branch structure from a single cantilever.

2008-05-21

345

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

346

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

347

Coherently pulsed laser source  

Energy Technology Data Exchange (ETDEWEB)

An electronically controllable apparatus is described which modulates a continuous wave laser beam so as to produce an output beam consisting of coherent ''pulses'' that are electronically controllable as to both pulse repetition rate and pulse width. The apparatus includes two acoustic devices positioned so that the laser beam passes through them in sequence, and apparatus or for passing sound waves through the devices to frequency shift the laser radiation as well as to diffract it. Each acoustic device such as generates sound waves containing a group of frequencies which result in spaced pulses. The spreading of a laser beam at which emanates from the first acoustic device is countered by the second acoustic device to produce a collimated, coherently pulsed, laser beam.

1982-06-01

348

Coherent Smith-Purcell radiation in the far-infrared region from a short-bunched electron beam  

International Nuclear Information System (INIS)

Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.

1995-09-28

349

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton beam from the Tevatron collider.

1999-01-01

350

Beam emittance measurements of ORNL negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

The emittances of hydrogen and deuterium negative ion beams produced by volume ion sources have been measured in a transverse plane normal to the beam trajectory. The extraction voltage was varied from 10 to 40 kV, and the transverse magnetic field in the Penning discharges was varied from 0.1 to 0.2 T. Measurements were made on beams with current densities up to 60 mA/cm/sup 2/ at Oak Ridge National Laboratory with an emittance scanner originally developed at Los Alamos National Laboratory. The beam profile at the scanner can be used to improve the accuracy of the emittance measurements. Other factors affecting emittance measurements are discussed. This analysis may be applicable to other ion sources. 6 figs.

1989-01-01

351

An identification method of positron production in laser beam interaction with targets  

Energy Technology Data Exchange (ETDEWEB)

A simple electromagnetic transport system was constructed to identify very rare positrons produced in a powerful laser beam interaction with a target. Testing experiments were carried out with CO[sub 2]-laser (10[sup 12] W/cm[sup 2]) beam pulses ([tau] = 50 ns, f = 0.01 Hz) focused on the copper target, as well as with a 96 MeV alpha-particle beam irradiated carbon target. The results showed that the developed system could be effectively used for positron identification and evaluation of their energy by means of a time-of-flight method. The computerized system to deal with this problem, together with others related to the power laser beam interaction with targets, has been constructed. (orig.).

1992-10-01

352

Comparison of the radiobiological effect of carbon ion beam therapy and conventional radiation therapy on cervical cancer  

International Nuclear Information System (INIS)

Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on ...

2008-09-01

353

Preparation of Permalloy nanostructures using focused ion beam methods  

International Nuclear Information System (INIS)

Focused ion beam (FIB) milling is a powerful and versatile tool for the maskless fabrication of structures and devices at micro- and nanometer scales. The approach is based on the milling and deposition capabilities of a focused ion beam, where the latter is achieved by ion-beam-assisted decomposition of a metalorganic gas precursor of the specific material that has to be deposited. The combination of FIB and scanning electron microscopy in the same unit (so-called dual-beam unit) further expands the capabilities of the approach by the possibility of performing electron-beam-assisted deposition and inspection. Permalloy nanowires with electrical contacts patterned by FIB-Pt deposition were prepared in the dual-beam unit. Various types of notches to pin magnetic domain walls were additionally fabricated by means of FIB. The fabrication parameters for a structural ...

2010-03-21

354

Interaction of energetic beams with metals and semiconductors - a computational approach  

International Nuclear Information System (INIS)

In a vacuum insulator, the narrow electron beam emitted from the cathode impinges on the anode and raises its temperature and also may produce high thermal stress. This high thermal stress, in conjuction with the surface electrostatic pressure may rupture the surface and detach particles from it. In this thesis, the interaction of high energy electron and laser beams with metals and semiconductors is investigated. The differential equations governing the physical processes involved in the interaction are solved by the finite element method. Effects of beam penetration into the material, variable beam reflectance at the surface, finite beam size and dependence of material properties on temperature are accounted for. The two-phase moving boundary problem, also known as the Stefan problem, is solved by an enthalpy formulation of the heat equation. Material deformation by thermal ...

1984-01-01

355

Implications of the Electrostatic Approximation in the Beam Frame on the Nonlinear Vlasov-Maxwell Equations for Intense Beam Propagation  

Energy Technology Data Exchange (ETDEWEB)

This paper develops a clear procedure for solving the nonlinear Vlasov-Maxwell equations for a one-component intense charged particle beam or finite-length charge bunch propagating through a cylindrical conducting pipe (radius r = r(subscript)w = const.), and confined by an applied focusing force. In particular, the nonlinear Vlasov-Maxwell equations are Lorentz-transformed to the beam frame ('primed' variables) moving with axial velocity relative to the laboratory. In the beam frame, the particle motions are nonrelativistic for the applications of practical interest, already a major simplification. Then, in the beam frame, we make the electrostatic approximation which fully incorporates beam space-charge effects, but neglects any fast electromagnetic processes with transverse polarization (e.g., light waves). The resulting Vlasov-Maxwell equations are then ...

2001-11-08

356

Free electron laser experiments using a long pulse induction linac  

International Nuclear Information System (INIS)

The NRL Long Pulse Induction Linac is being employed in a Free Electron Laser (FEL) experiment. The authors present results of beam transport and focusing experiments as well as measurements of the output radiation generated by various magnetic wigglers. The electron gun of the accelerator presently has a 17-cmdiam. cold cathode which is located in a nearly zero magnetic field (B /SUB z/ less than or equal to 5 G). The gun voltage is flat to within approx. = + or - 5% for 1.5 #mu#sec with this graphite brush cathode. The beam is focused by a series of solenoidal coils as it propagates through the 4-m-long accelerator."2 A solenoidal field which can be varied from 1-10 kG confines the beam in the FEL interaction region. Previous experiments were limited by poor beam transport, focusing, and matching into the relatively large solenoidal field in the FEL region. By smoothing the axial magnetic field ...

357

Fast Implementation of Matched Filter Based Automatic Alignment Image Processing  

Energy Technology Data Exchange (ETDEWEB)

Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field ...

2008-04-02

358

Effect of triple ion beams in ferritic/martensitic steel on swelling behavior  

Energy Technology Data Exchange (ETDEWEB)

The synergistic effects of displacement damage and atomic hydrogen and helium on swelling of the ferritic/martensitic steel, F82H, has been investigated. The irradiation was performed at temperatures between 470 and 600 deg. C to 50 dpa (displacement per atoms) under conditions of simultaneous ion beams consisting of Fe{sup 3+}, He{sup +} and H{sup +} ions or Fe{sup 3+} and He{sup +} ions. The swelling of F82H steel under triple beams with 18 appm He/dpa and 70 appm H/dpa was larger than that under dual beams with 18 appm He/dpa. The swelling in F82H under triple beams increased with decreasing irradiation temperature from 0.1% to 3.2%, while swelling under dual beams was between 0.04% and 0.08%. On the other hand, in the case of triple beam irradiation with a high ratio of gas/dpa, the swelling tended to increase with irradiation temperature. The swelling in ...

2002-12-01

359

Effect of triple ion beams in ferritic/martensitic steel on swelling behavior  

International Nuclear Information System (INIS)

The synergistic effects of displacement damage and atomic hydrogen and helium on swelling of the ferritic/martensitic steel, F82H, has been investigated. The irradiation was performed at temperatures between 470 and 600 deg. C to 50 dpa (displacement per atoms) under conditions of simultaneous ion beams consisting of Fe"3"+, He"+ and H"+ ions or Fe"3"+ and He"+ ions. The swelling of F82H steel under triple beams with 18 appm He/dpa and 70 appm H/dpa was larger than that under dual beams with 18 appm He/dpa. The swelling in F82H under triple beams increased with decreasing irradiation temperature from 0.1% to 3.2%, while swelling under dual beams was between 0.04% and 0.08%. On the other hand, in the case of triple beam irradiation with a high ratio of gas/dpa, the swelling tended to increase with irradiation temperature. The swelling in ferritic/martensitic ...

2002-12-01

360

Chromosome aberrations in human lymphocytes from the plateau region of the Bragg curve for a carbon-ion beam  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy with high-energy carbon ion beams can be more advantageous compared to photons because of better physical dose distribution and higher biological efficiency in tumour cell sterilization. Despite enhanced normal tissue sparing, damage incurred by normal cells at the beam entrance is unavoidable and may affect the progeny of surviving cells in the form of inheritable cytogenetic alterations. Furthermore, the quality of the beam along the Bragg curve is modified by nuclear fragmentation of projectile and target nuclei in the body. We present an experimental approach based on the use of a polymethylmethacrylate (PMMA) phantom that allows the simultaneous exposure to a particle beam of several biological samples positioned at various depths along the beam path. The device was used to measure the biological effectiveness of a 60 MeV/amu carbon-ion beam at ...

2007-06-15

361

BNL Neutral Beam Development Group. Progress report, FY 1983 and final report  

Energy Technology Data Exchange (ETDEWEB)

The BNL Neutral Beam Development Group has been active in the program for the development of high energy, high power neutral beam systems since 1973. These injectors are based on the production, acceleration and neutralization of negative hydrogen or deuterium ions and are supposed to be used for plasma heating and current drive in the next generation of fusion devices. Over the span of 10 years the group has studied plasma-surface type of negative hydrogen ion sources, transport and acceleration of negative ion beams and neutralization of negative ions in gases and plasmas. As the required source parameters (current, pulse length, efficiency) were changing over this period of time, the group developed several types of sources, resulting finally in the design of a steady state device operating with an excellent gas efficiency and having the possibility of scaling-up to the size necessary for a high power neutral ...

1984-03-16

362

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate calculation of zone power is carried out by FMS ...

2006-11-13

363

The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced ...

364

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

Energy Technology Data Exchange (ETDEWEB)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-15

365

Target fabrication of low-density and nano porous materials to generate extreme ultraviolet (EUV)  

International Nuclear Information System (INIS)

Our institute has been investigating laser-produced tin, lithium and xenon plasma for extreme ultraviolet (EUV) light source of EUV lithography system, and found the highest conversion efficiency of 3% at 13.5 nm in 2% bandwidth. In the present paper, we introduce fabrication methods of density-controlled tin targets to generate relatively monochromatic EUV, and higher conversion efficiency than bulk tin. The first method is the nano-template method, where liquid tin solution was immersed into a polymer film with monodispersed size nano-particle. The density can be controlled by tin concentration of the solution. The target can be classified into mass-limited target. We have shown a tendency of monochromatic EUV emission around 13.5 nm with decreasing of tin density. The intensity was higher than tin foil with bulk density. The tendency has a merit to mitigate heat effect of the first EUV mirror. The fabrication method has another merit to control not only density ...

2006-06-01

366

Adsorption equilibria of krypton, xenon, nitrogen and their mixtures on Molecular Sieve 5A and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

The adsorption equilibria of Kr, Xe and N{sub 2}, which are constituents of the off-gas from nuclear reprocessing processes, on representative adsorbents (Molecular Sieve 5A (MS5A) and activated charcoal) were studied. Adsorption experiments were conducted in the temperature range of 77 to 323 K using a packed bed column. The adsorption isotherms for the activated charcoal adsorbent were successfully correlated by the vacancy solution model. The adsorption isotherms for the MS5A adsorbent were properly correlated by the Langmuir model and the vacancy solution model. The adsorption experiments for the binary component systems (Kr-Xe, Kr-N{sub 2} systems) were also performed, and the results suggest that the coexistence of Xe greatly inhibits the adsorption of Kr. The coexistence of large amounts of N{sub 2} was also found to inhibit the adsorption of Kr. The experimental results for the adsorption equilibrium of binary component systems on the activated charcoal adsorbent were well ...

1999-09-01

367

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...

1990-11-01

368

Study of iodine migration in zirconia using stable and radioactive ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using radioactive {sup 131}I ...

1998-03-01

369

Solvent extraction using tetracycline as complexing agent Pt. 14. Study of the behaviour of tetracycline as an extracting agent for some fission products  

Energy Technology Data Exchange (ETDEWEB)

The behaviour of tetracycline as an extracting agent for Sr, I, Ba, Mo, Tc, Zr, Nb, Cs, Ru, Te and U was studied and the influence of the acidity of the aqueous phase upon extraction of the elements mentioned was examined. Experiments were made to determine whether the species extracted into the organic phase is the complex formed between tetracycline and the elements considered and to determine the time of shaking necessary so that the equilibrium between the phases is attained. As a practical application, the possibility of using the tetracycline-benzyl alcohol system for separating the fission products sup(137)Cs, sup(140)La, sup(141)Ce, sup(103)Ru, sup(95)Nb from each other and from uranium is presented. The same study was made for sup(131)I, sup(99m)Tc, sup(99)Mo, sup(132)Te, sup(239)Np and uranium and the steps necessary for the separation of these elements are proposed.

1985-10-01

370

Separation of trace radionuclides by ion exchange in the presence of competing ions  

International Nuclear Information System (INIS)

The performance of larger than bench scale ion exchange systems is evaluated by using solutions containing trace amounts of "1"3"7Cs, "8"5Kr, and "1"3"1I, and large amounts of either NaCl or Na_2HPO_4, H_3BO_3, and LiOH. The significant finding in this study is that the empirical rules of ionic selectivity of strong acid cation and strong base anion resins were followed by all ionic species, even though concentrations of some macrocomponents were nearly 10"6 times those of trace components. Other results of possible importance are the correlation between the instantaneous decontamination factor (DF) and the efficiency of column exchange capacity utilization, and the concept of time average decontamination factor (anti DF). The plot of anti DF vs. feed throughput will serve as a guide in determining when the feed should be discontinued in order to achieve a desired anti DF. Both of these correlations are derived from the breakthrough curves.

371

Radiohalogen-labeled imaging agents. 3. Compounds for measurement of brain blood flow by emission tomography  

Energy Technology Data Exchange (ETDEWEB)

The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...

1984-08-01

372

Radiohalogen-labeled imaging agents. 3. Compounds for measurement of brain blood flow by emission tomography  

International Nuclear Information System (INIS)

The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...

373

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, respectively, and were not ...

1980-01-01

374

Proposal to negotiate an amendment to an existing contract for the supply of thick 6 inch silicon micro-strip sensors for the CMS tracker  

CERN Document Server

This document concerns the proposal to negotiate an amendment to an existing contract for the supply of thick 6 inch silicon micro-strip sensors for the CMS tracker. For the reasons explained in this document, the Finance Committee is invited to approve an amendment to an existing contract with HAMAMATSU PHOTONICS (CH) for the supply of 7 000 thick 6 inch silicon micro-strip sensors for the CMS tracker, for an amount of 3 248 000 euros (5 131 840 Swiss francs), not subject to revision, with an option for up to 11 000 additional sensors, for a maximum amount of 4 708 000 euros (7 438 640 Swiss francs), not subject to revision, bringing the total maximum amount of the amendment to 7 956 000 euros (12 570 480 Swiss francs) not subject to revision. This total maximum amount will be added to the initial contract amount of 415 835 000 Japanese yen (4 879 824 Swiss francs), not subject to revision. The amounts in Swiss francs have been calculated using the present rate of ...

2004-01-01

375

Platelet thrombosis in cardiac-valve prostheses  

International Nuclear Information System (INIS)

The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day ...

1989-06-08

376

Plastic instability in an omega forming Ti-l5% Mo alloy  

International Nuclear Information System (INIS)

The plastic flow behavior of a #beta#-titanium alloy (Ti-15% Mo) was investigated over a wide range of temperatures and strain rates covering those conditions where the #omega#-phase forms dynamically. Portevin-Le Chatelier (PLC) effect was observed in this alloy at temperatures between 575 and 775 K at a strain rate of 1.31 x 10"-"4 s"-"1. The serrated flow behavior of this alloy could be suppressed by rendering the matrix #beta#-phase more stable against the #beta# to #omega# transformation. PLC bands formed in this alloy, studied at different levels of magnification using light, scanning electron and transmission electron microscopy, showed a high density of deformation bands within the macroscopic PLC band. The following mechanism of serrated flow is proposed; the load drop is ascribed to the sudden flow associated with the formation of deformation bands within which #omega#-particles were destroyed while the subsequent load rise results from pinning of ...

377

Photophysical characteristics of 4,4'-bis(N-carbazolyl)tolan derivatives and their application in organic light emitting diodes  

International Nuclear Information System (INIS)

4,4'-bis(N-carbazolyl)tolan (BCT) and 4,4'-bis[N-(3,6-di-t-butyl)carbazolyl]tolan (BCT-t-Bu) were synthesized as ?-expanded analogs of 4,4'-bis(N-carbazolyl)biphenyl. Their photophysical characteristics both in solution and films were thoroughly investigated. Interestingly, the phosphorescence spectrum of BCT was significantly medium-dependent, and the emission maximum was red-shifted by 131 nm from 489 nm in solution at 77 K to 620 nm in a deposited film at 5 K, suggesting the presence of strong intermolecular interactions in the film. BCT and BCT-t-Bu were found to be useful as host materials for fluorescence-based organic light emitting diodes (OLEDs). However, their low triplet energy levels in films negated their potential to act as hosts in phosphorescence-based OLEDs. - Research highlights: ? We synthesized N-carbazolyl-tolan derivatives (BCT) as ?-expanded analogues of CBP. ? We found that BCT derivatives are useful as host materials for fluorescence-based ...

2011-07-01

378

Phenylpiperazine-based radiopharmaceuticals for brain imaging. 3. Synthesis and evaluation of radioiodinated 1-alkyl-4-phenylpiperazines  

International Nuclear Information System (INIS)

As part of our program in radiopharmaceutical chemistry we have prepared and evaluated a series of radioiodinated 1-alkyl-4-phenylpiperazines as potential brain-imaging agents. The compounds were chosen on the basis of their synthetic versatility, activation toward electrophilic substitution, and ease of purification. The intermediates 1-6 were readily obtained and converted to the corresponding radioiodinated products 7-12 in 76-91% isolated radiochemical yields. The tissue distribution in rats indicated that the 1-N-butyl derivative 9 possesses the best combination of brain uptake (0.28-0.35% ID X kg/g), retention, and selectivity (brain/blood greater than 20) over the 4-h evaluation period. A subsequent imaging and tissue distribution study in the dog using 131I-labeled 9 supported the results observed in the rat and suggested the potential of this agent as a brain-imaging agent.

379

Nanosized high voltage cathode material LiMg{sub 0.05}Ni{sub 0.45}Mn{sub 1.5}O{sub 4}: Structural, electrochemical and in situ investigation  

Energy Technology Data Exchange (ETDEWEB)

In this study a modified solid state synthesis (auto-ignition method) is used to form nanosized spinel type material LiMg{sub 0.05}Ni{sub 0.45}Mn{sub 1.5}O{sub 4}. This material presents a high voltage plateau at 4.75 V vs. Li/Li{sup +}. Structural and electrochemical characterisations have been performed using a wide range of techniques (TEM, neutron diffraction, galvanostatic measurements, and impedance spectroscopy). Besides, in situ XAS has been performed to monitor the evolution of Ni and Mn oxidation state during Li intercalation. The material presents an ordered cubic spinel structure, good capacity retention upon cycling (131 mAh g{sup -1} at C/10 and 117 mAh g{sup -1} at 1C) and good electronic conductivity (10{sup -6} S cm{sup -1} at RT). The simultaneous presence of Mn{sup 3+}/Mn{sup 4+} in the structure has been investigated and explained by inclusion of disordered nanodomains in the structure. (author)

2009-04-01

380

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

381

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

382

Influence of valency and labelling chemistry on in vivo targeting using radioiodinated HER2-binding Affibody molecules  

British Library Electronic Table of Contents (United Kingdom)

Purpose HER2 is a transmembrane tyrosine kinase, which is overexpressed in a number of carcinomas. The Affibody molecule ZHER2:342 is a small (7?kDa) affinity protein binding to HER2 with an affinity of 22?pM. The goal of this study was to evaluate the use of ((4-hydroxyphenyl)ethyl)maleimide (HPEM) for radioiodination of ZHER2:342 and to compare the targeting properties of monomeric and dimeric forms of ZHER2:342. Methods The biodistribution of different radioiodinated derivatives of ZHER2:342 was studied in BALB/C nu/nu mice bearing HER2-expressing SKOV-3 xenografts. Biodistributions of 125I-PIB-ZHER2:342 and site-specifically labelled 125I-HPEM-ZHER2:342-C were compared. Biodistributions of monomeric 131I-HPEM-ZHER2:342-C and dimeric 125I-HPEM-(ZHER2:342)2-C were evaluated using a paire...

2009-01-01

383

Influence of second phase particles on fracture toughness in AZ31 magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

Three kinds of thin AZ31 wrought magnesium alloys sheets were used in order to investigate the influence of the second phase particles on fracture toughness. From the theoretical model, the ratio of {lambda}{sub p}/d{sub p} would be estimated 5 {proportional_to} 6. On the other hand, from the microstructural observation, average particle spacing on each material was sample A: 13.1 {mu}m, sample B: 14.1, and sample C: 12 {mu}. In addition, average particle size on each sample was sample A: 2.1, sample B: 1.9, and sample C: 2.3 {mu}m. Therefore, the ratio of {lambda}{sub p}/d{sub p} calculated from fracture surface observation would be predicted 6 {proportional_to} 7. In comparison with the result of the prediction by theoretical analysis was in good agreement with the result of fracture toughness observation. It was found that the variation in plane-strain fracture toughness on AZ31 were affected by both of particle spacing and particle size. (orig.)

2004-07-01

384

Inclusive search for doubly charged higgs in leptonic final states at sqrt s=7 TeV  

CERN Document Server

A search for the doubly charged Higgs boson, a member of $SU(2)_L$ scalar triplet $\\Phi$ participating in the seesaw mechanism of type II, in $pp$ collisions at $\\sqrt{s}=7$~TeV is presented. The data correspond to an integrated luminosity of 36 $\\text{pb}^{-1}$ collected by the CMS experiment at the LHC. The inclusive search is performed in events with three and four isolated charged leptons of all flavours originating from the decays of pair produced triplet components $\\Phi^{++}\\Phi^{--}$ and $\\Phi^{++}\\Phi^{-}.$ With the present collected luminosity the CMS experiment is sensitive to the $\\Phi$ mass range in which the possible decays $\\Phi^{++}\\to W^{+}W^{+}$ are forbidden kinematically. No signal excess is observed and lower limits at the 95\\% confidence level are set on the $\\Phi^{++}$ mass of 156\\GeV in the $\\mu\\mu$ channel, $154\\GeV$ in e$\\mu$ channel, of $144\\GeV$ in $ee$ channel and between $116\\GeV$ and $131\\GeV$ in the four defined ...

2011-01-01

385

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin is taken up by the amyloid deposits. This ...

1990-12-01

386

IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9  

Science.gov (United States)

Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs with special reference ...

1962-01-01

387

Fast determination of molybdenum and tellurium by neutron activation analysis  

International Nuclear Information System (INIS)

The utilization of 14.6-min "1"0"1Mo and 25-min "1"3"1Te for the determination of molybdenum and tellurium in biological materials by neutron activation analysis is described for the first time. Radioisotopes were separated from the samples activated in a thermal neutron flux of about 10"1"4 n cm"-"2s"-"1. The radiochemical procedure for molybdenum involves extraction of Mo"6"+ from 6 M HCl into diethylether, re-extraction into water, precipitation as oxinate, and measurement of the gamma activity of "1"0"1Tc. The tellurium was separated by reduction to the element with SO_2 in 3 M HCl, dissolution in HNO_3, and reprecipitation as the element for the measurement of radioactivity. The sensitivity was estimated at ca. 10 ng at the level of confidence of 95%. The methods were tested by analyzing NBS-standard Bovine Liver and Orchard Leaves for molybdenum; the concentrations found were 3.2 +- 0.1 #mu#g g"-"1 and 300 +- 60 ng g"-"1, respectively. The tellurium content ...

388

Evaluation of the radioprotective effect of turmeric extract and vitamin E in mice exposed to therapeutic dose of radioiodine  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the radioprotective effect of turmeric extract (40 mg/kg body weight) and vitamin E (#alpha# - tocopherol acetate, 400 IU/kg body weight) supplementation on lipid peroxidation, reduced glutathione and antioxidant defense enzymes in various organs like liver, kidney and salivary glands at 24 h in adult Swiss mice. "1"3"1Iodine exposure significantly increased lipid peroxidation in kidney and salivary glands in comparison to control animals. Pre supplementation with turmeric extract for 15 days showed significant lowering of lipid peroxidation in kidney. On the other hand vitamin E pre supplementation showed marked reduction in lipid peroxidation in salivary glands. Reduced glutathione levels decreased significantly in liver after radiation exposure. However, pre supplementation with turmeric extract and vitamin E did not improve glutathione levels in liver. In conclusion we have observed differential radioprotective effect of ...

2008-10-01

389

Estimation of parameters affecting the uptake of sup(99m)Tc-methylenediphosphonate in rat femur with model simulation  

Energy Technology Data Exchange (ETDEWEB)

The uptake of sup(99m)Tc-methylenediphosphonate (MDP) in different parts of rat femur was simulated using a local three-space model for tracer transfer. The model consisted of bone blood, bone ECF-space and space for tracer deposition. The measured sup(99m)Tc-MDP concentration in the systemic blood and the local bone blood flow measured by /sup 131/I-macroaggregated albumin microspheres were used as input parameters. The measured blood flow values were 6.3, 3.1 and 15.3 ml/100 g/min for proximal, middle and distal femur, respectively. the model parameters that gave the best fit to measured sup(99m)Tc-MDP uptake curves in computer simulation showed that bone blood flow, volume of ECF-space, permeability surface area product and accretion constant from ECF-space to space for tracer deposition were highest in distal and lowest in middle femur. The values corresponded to peak extraction fractions of 0.38, 0.62, and 0.31 for proximal, middle and distal femur, ...

1985-01-01

390

Estimation of parameters affecting the uptake of sup(99m)Tc-methylenediphosphonate in rat femur with model simulation  

International Nuclear Information System (INIS)

The uptake of sup(99m)Tc-methylenediphosphonate (MDP) in different parts of rat femur was simulated using a local three-space model for tracer transfer. The model consisted of bone blood, bone ECF-space and space for tracer deposition. The measured sup(99m)Tc-MDP concentration in the systemic blood and the local bone blood flow measured by "1"3"1I-macroaggregated albumin microspheres were used as input parameters. The measured blood flow values were 6.3, 3.1 and 15.3 ml/100 g/min for proximal, middle and distal femur, respectively. the model parameters that gave the best fit to measured sup(99m)Tc-MDP uptake curves in computer simulation showed that bone blood flow, volume of ECF-space, permeability surface area product and accretion constant from ECF-space to space for tracer deposition were highest in distal and lowest in middle femur. The values corresponded to peak extraction fractions of 0.38, 0.62, and 0.31 for proximal, middle and distal femur, respectively. ...

391

Chiral salicyloxazolines as auxiliaries for the asymmetric synthesis of ruthenium polypyridyl complexes.  

Science.gov (United States)

Chiral auxiliaries are promising emerging tools for the asymmetric synthesis of octahedral metal complexes. We recently introduced chiral salicyloxazolines as coordinating bidentate chiral ligands which provide excellent control over the metal-centered configuration in the course of ligand substitution reactions and can be removed afterward in an acid-induced fashion under complete retention of configuration (J. Am. Chem. Soc. 2009, 131, 9602-9603). Here reported is our detailed investigation of this sequence of reactions, affording virtually enantiopure ruthenium polypyridyl complexes. The control of the metal-centered chirality by the coordinated chiral salicyloxazolinate ligand was evaluated as a function of reaction conditions, the employed bidentate 2,2'-bipyridine and 1,10-phenanthroline ligands, and the substituent at the asymmetric 5-position of the oxazoline heterocycle. Most striking was the strong influence of the reaction solvent, with aprotic solvents ...

2010-09-01

392

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present plain flat tube showed a higher in heat transfer and pressure ...

2011-01-15

393

Assessment of egg quality and realised fecundity of whiting Merlangius merlangus L. in captivity  

British Library Electronic Table of Contents (United Kingdom)

Summary Potential predictors of egg quality were assessed in whiting Merlangius merlangus L. permitted to spawn in a tank from which eggs were collected. These included fertilisation rate, the proportion of viable buoyant eggs, egg diameter, and egg wet and dry weights; all were influenced by temporal effects and were negatively correlated with days from start of spawning. The spawning period was protracted, from February to June. Mean daily egg production per female was 2.74 +- 2.43 g and 2338 +- 2075 eggs, equivalent to 14.6 +- 13.1 g kg-1 day-1 female-1. Egg diameter was 1.21 +- 0.04 mm, egg wet weight 1.20 +- 0.21 mg, dry weight 0.10 +- 0.02 mg, and mean fertilisation rate and hatching rates were 76.8 and 73.3%, respectively. The incubation period ranged from 72 to 80 degree days and w...

2010-01-01

394

"2"1"1At-Rh(16-S4-diol) complex as a precursor for astatine radiopharmaceuticals  

International Nuclear Information System (INIS)

"2"1"1At is one of the most promising radionuclides in #alpha#-radioimmunotherapy (#alpha#-RIT). Unfortunately, biomolecules labeled by direct electrophilic astatination are unstable due to the rapid loss of "2"1"1At under both in vitro and in vivo conditions. The present paper describes the results of our studies on attaching At"- to the rhodium(III) complex with thioether ligand: 1,5,9,13-etrathiacyclohexadecane-3,11-diol (16-S4-diol). Rh"3"+ was chosen as a moderately soft metal cation which should form very strong bonds with soft At"- anions, but first of all because of the kinetic inertness of low spin rhodium(III) d"6 complexes. The 16-S4-diol ligand was selected due to formation of stable complexes with Rh"3"+. The experiments related to optimization of the reaction conditions were performed with the "1"3"1I, basing on a chemical similarity of I"- to At"-. The experiments with "2"1"1At were then carried out under the conditions found optimal for I"-. The ...

395

Uranium-lead zircon ages from the Median Tectonic Zone, New Zealand  

International Nuclear Information System (INIS)

The Median Tectonic Zone (MTZ) of New Zealand is a generally north trending belt of Mesozoic subduction related I-type plutonic, volcanic, and sedimentary rocks in South Island and Stewart Island that separates Permian strata of the Eastern Province Brook Street Terrane from lower to mid Gondwana margin assemblages of the Western Province. High precision isotope dilution U/Pb ages of zircons from 30 rocks are reported. Pre-digestion leaching of zircon in hydrofluoric acid yielded significantly more concordant residues by removing common Pb and dissolving more soluble high-U domains that have been more affected by relatively recent Pb loss. The results show that MTZ magmatism ranges in age from at least Early Triassic to Early Cretaceous (247-131 Ma), with a pronounced gap in the Middle Jurassic. Triassic plutons tend to occur on the eastern side of the MTZ, and they intrude volcanic/sedimentary sequences of the MTZ in Nelson and eastern Fiordland. These sequences ...

396

Towards an objective evaluation of tolerances for beam modeling in a treatment planning system  

International Nuclear Information System (INIS)

The performance of a convolution/superposition based treatment planning system depends on the ability of the dose calculation algorithm to accurately account for physical interactions taking place in the tissue, key components of the linac head and on the accuracy of the photon beam model. Generally the user has little or no control over the performance of the dose calculation algorithm but is responsible for the accuracy of the beam model within the constraints imposed by the system. This study explores the dosimetric impact of limitations in photon beam modeling accuracy on complex 3D clinical treatment plans. A total of 70 photon beam models was created in the Pinnacle(TM) treatment planning system. Two of the models served as references for 6 MV and 15 MV beams, while the rest were created by perturbing the reference models in order to produce specific deviations in specific ...

2007-09-21

397

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for ...

398

Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit  

Energy Technology Data Exchange (ETDEWEB)

Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ?ce > ?pe?b, where ?ce = e?/mec is the electron gyrofrequency, ...

2008-10-10

399

Beam direct converter with varying magnetic field  

Energy Technology Data Exchange (ETDEWEB)

The concept of a direct energy recovery system that applies a varying magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. The output beam energy and power of such an NNB will be {approximately}1 MeV and {approximately}1- MW/beam-line, respectively, and nearly the same amounts of positive- and negative-ion beams remain unneutralized in an NNB by using a gas-neutralizing cell. Therefore, the output of a beam direct convertor in an NNB is a bipolar direct current (dc) electric power with close to {plus_minus} 1 MV and several amperes if a conventional electrostatic or magnetostatic field is applied for ion beam separation. However, such high-voltage dc power is difficult to handle at the point of the regeneration of the power back to a commercial electric line ...

1994-12-01

400

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...

2008-02-21

401

Vibration characteristics of SMA composite beams with different boundary conditions  

Energy Technology Data Exchange (ETDEWEB)

Recently, the development of shape memory alloy (SMA) actuators, in the forms of wire, thin film and stent have been found increasingly in the fields of materials science and smart structures and engineering. The increase in attraction for using these materials is due to their many unique materials, mechanical, thermal and thermal-mechanical properties, which in turn, evolve their subsequent shape memory, pseudo-elasticity and super-elasticity properties. In this paper, a common type of SMA actuator, Nitinol wires, were embedded into advanced composite structures to modulate the structural dynamic responses, in terms of natural frequency and damping ratio by using its shape memory and pseudo-elastic properties. A simple theoretical model is introduced to estimate the natural frequency of the structures before and after actuating the embedded SMA wires. The damping ratios of different SMA composite beams were measured through experimental approaches. The natural ...

2002-12-15

402

TPX Neutral Beam Injection System design  

International Nuclear Information System (INIS)

The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major ...

1993-10-11

403

Simulation of a Standing-Wave Free-Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

The standing-wave free-electron laser (FEL) differs from a conventional linear-wiggler microwave FEL in using irises along the wiggler to form a series of standing-wave cavities and in reaccelerating the beam between cavities to maintain the average energy. The device has been proposed for use in a two-beam accelerator (TBA) because microwave power can be extracted more effectively than from a traveling-wave FEL. The standing-wave FEL is modeled in the continuum limit by a set of equations describing the coupling of a one-dimensional beam to a TE{sub 01} rectangular-waveguide mode. Analytic calculations and numerical simulations are used to determine the time variation of the reacceleration field and the prebunching required so that the final microwave energy is the same in all cavities. The microwave energy and phase are found to be insensitive to modest spreads in the beam energy and phase and to ...

1990-09-01

404

Production of negative ions by electron impact. Final report 1 May 81-31 Oct 82  

Science.gov (United States)

Proposed future space-based beam weapons systems will most probably require an intense neutral particle beam for effective operation across geomagnetic field lines. Such neutral beams can most efficiently be obtained by stripping excess electrons from negative ion beams. The objective of this work is to study the process of dissociative attachment of electrons. Specifically, to measure the cross sections for polar dissociation and dissociative attachment for production of H(-). It is suspected that these dissociative attachment cross sections for the production of H(-) from alkali hydrides are large. The insight gained from this study will be extremely helpful in the fabrication of high current density H(-) beam sources for use in the production of intense neutral hydrogen beams. A selection of alkali hydride molecules will be investigated in order to determine ...

1982-10-01

405

Microfabrication processes for high-T_c superconducting films  

International Nuclear Information System (INIS)

Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce submicrometer ...

406

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...

2007-08-21

407

Large area electron beam pumped krypton fluoride laser amplifier  

International Nuclear Information System (INIS)

Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a ...

408

Improved method for producing negative ion beams from the group IIA elements for tandem Van de Graaff applications  

Energy Technology Data Exchange (ETDEWEB)

A brief description of a method for producing relatively intense molecular negative ion beams for the difficult Group IIA elements is given which offers considerable improvement in terms of source operation and beam intensity stability over other methods conventionally utilized. It is particularly suited for use in cesium plasma sources such as the Aarhus geometry and axial geometry versions of the source. The method utilizes H/sub 2/ source feed gas for the production of a hydrogen-rich plasma discharge which sputters a negatively biased probe made of elemental or copper alloy material. Negative ion beams of MgH/sub 3//sup -/>=12 ..mu.. A have been realized during routine operation of the 25 MV tandem accelerator. Negative ion beam intensity data, typical source operational parameters, and examples of mass spectra associated with their production are given. Interesting intermetallic molecular ...

1983-06-01

409

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m ...

2003-06-01

410

Focused ion beam techniques for fabricating geometrically-complex components and devices.  

Energy Technology Data Exchange (ETDEWEB)

We have researched several new focused ion beam (FIB) micro-fabrication techniques that offer control of feature shape and the ability to accurately define features onto nonplanar substrates. These FIB-based processes are considered useful for prototyping, reverse engineering, and small-lot manufacturing. Ion beam-based techniques have been developed for defining features in miniature, nonplanar substrates. We demonstrate helices in cylindrical substrates having diameters from 100 {micro}m to 3 mm. Ion beam lathe processes sputter-define 10-{micro}m wide features in cylindrical substrates and tubes. For larger substrates, we combine focused ion beam milling with ultra-precision lathe turning techniques to accurately define 25-100 {micro}m features over many meters of path length. In several cases, we combine the feature defining capability of focused ion beam bombardment with ...

2004-03-01

411

Fabrication of nanometer structures by means of a fine-focused ion beam  

International Nuclear Information System (INIS)

Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal deposition is given. The layer quality is ...

2000-03-01

412

Effects of Intensity and Position Modulation On Switched Electrode Electronics Beam Position Monitor Systems at Jefferson Lab  

Energy Technology Data Exchange (ETDEWEB)

Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other, called the transport type, has a switching frequency of 7 kHz. The basic system provides information to the control system at a 1 Hz update rate. The systems are regularly used to measure the AC component of beam position and energy as well as suppress this motion as part of a fast feedback system. Position data produced by the system are also acquired on an event by event basis as part of the nuclear physics program in two of the experimental halls. This paper will focus on the AC characteristics of the system. These characteristics are affected by analog filter frequencies and a time delay between the measurement ...

2000-05-01

413

Drift compression and final focus systems for heavy ion inertial fusion  

Energy Technology Data Exchange (ETDEWEB)

Longitudinal compression of space-charge dominated beams can be achieved by imposing a head-to-tail velocity tilt on the beam. This tilt has to be carefully tailored, such that it is removed by the longitudinal space-charge repulsion by the time the beam reaches the end of the drift compression section. The transverse focusing lattice should be designed such that all parts of the beam stay approximately matched, while the beam smoothly expands transversely to the larger beam radius needed in the final focus system following drift compression. In this thesis, several drift compression systems were designed within these constraints, based on a given desired pulse shape at the end of drift compression systems were designed within these constraints, based on a given desired pulse shape at the end of drift compression. The occurrence of mismatches due to a rapidly ...

2001-05-01

414

Development of high power negative ion sources for fusion at JAERI  

Energy Technology Data Exchange (ETDEWEB)

Technologies producing high power negative ion beams have been highly developed in these years at JAERI for use in neutral beam injectors for heating the thermonuclear fusion plasmas. At present, it is possible to produce multi-ampere H-/D- ion beams quasi-continuously at energies more than a few hundred keV with a good beam optics of beamlet divergence of a few milli-radian. Based on these technologies, two R and D projects have been initiated; one is to develop a 22A/500keV/10s D- ion source for the neutral beam injector for JT-60U, and the other is to develop a 1A/1MeV/60s H- ion source to demonstrate high current negative ion acceleration up to the energy of 1MeV, the energy required for the neutral beam injector for International Thermonuclear Experimental Reactor (ITER). (author).

1995-10-01

415

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been ...

2002-01-01

416

Beam pattern diagnosis and adjustment guidance for cyclotron based on fuzzy relation  

Energy Technology Data Exchange (ETDEWEB)

An adjustment support system using computer for start-up operation of cyclotron is being developed in order to support operators who, using their experiences and intuition, tune up dozens of components to maximize beam efficiency. This paper describes a method of beam pattern diagnosis and adjustment guidance based on fuzzy relation as one function of the adjustment support system. The followings are the basic processes of this method. (1) The computer extracts features of beam pattern which correspond with operators' criteria. (2) The computer calculates causative possibility of each adjustment parameters by inverse operation of fuzzy relational equation, which formulates the relationship between criteria of beam pattern and adjustment parameters. (3) The computer displays those causative probabilities in a graphical manner as a operation guidance. Not only the probabilities but also the ...

1990-08-01

417

Atmospheric scintillations and laser safety  

Science.gov (United States)

Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a ...

2011-09-01

418

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider ...

1994-11-14

419

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

420

The effects of the focus ion beam milling process on the optical properties of semiconductor nanostructures  

International Nuclear Information System (INIS)

In this work, the effects of the focus ion beam (FIB) milling process on the optical properties of semiconductor nanostructures were investigated. With this aim, a sensitive materials system based on InGaAs/GaAs quantum dots with well known and excellent optical properties was selected for the FIB treatment. The FIB technique was used to locally remove a metallic mask deposited on top of the quantum dot sample. The photoluminescence (PL) signal, collected from the circular openings, was used to infer the possible damage effects of the ion beam on the properties of the dots.

2009-06-24

421

The application of advanced techniques for complex focused-ion-beam device modification  

Energy Technology Data Exchange (ETDEWEB)

Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).

1996-12-31

422

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

423

Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler  

Energy Technology Data Exchange (ETDEWEB)

A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.

1986-09-01

424

Solenoid transport for heavy ion fusion  

Energy Technology Data Exchange (ETDEWEB)

Solenoid transport of high current, heavy ion beams is considered for several stages of a heavy ion fusion driver. In general this option is more efficient than magnetic quadrupole transport at sufficiently low kinetic energy and/or large e/m, and for this reason it has been employed in electron induction linacs. Ideally an ion beam would be transported in a state of Brillouin flow, i.e. cold in the transverse plane and spinning at one half the cyclotron frequency. The design of appropriate solenoids and the equilibrium and stability of transported ion beams are discussed. An outline of application to a fusion driver is also presented.

2004-06-15

425

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

426

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

427

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

Energy Technology Data Exchange (ETDEWEB)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga{sup +} ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

428

Self-organized amorphous material in silicon (0 0 1) by focused ion beam (FIB) system  

International Nuclear Information System (INIS)

A method using a focused ion beam (FIB) to prepare a silicon amorphous material is presented. The method involves the redeposition of sputtered material generated during the interaction of the Ga"+ ion beam with a silicon substrate material. The shape and dimensions of this amorphous material are self-organized and reproducible. The stability of this amorphous material under electron irradiation was investigated in the transmission electron microscopy (TEM). Electron irradiation can induce recrystallization of the amorphous material, resulting in the lateral and vertical growth, starting at an amorphous-crystalline interface, of polysilicon containing defects.

2005-12-15

429

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

430

Radio frequency He/sup -/ source and a source of negative ions by cesium sputtering  

Energy Technology Data Exchange (ETDEWEB)

Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.

1981-04-01

431

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

Energy Technology Data Exchange (ETDEWEB)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr{sup -}and 20 nA for SrO{sup -}. (orig.).

1996-09-11

432

Production of Group IIA atomic and molecular negative ion beams in a cesium-sputter negative ion source  

International Nuclear Information System (INIS)

The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr"-and 20 nA for SrO"-. (orig.).

1996-09-01

433

Optical pressure on thin film caused by a Gaussian beam-generated evanescent wave  

International Nuclear Information System (INIS)

The optical pressure exerted o a thin film, which is locked in the evanescent field formed at the plane interface with a totally-reflected Gaussian beam, is investigated. Some calculations of the pressure on the film caused by the evanescent field are presented in the different conditions of film thickness, film position, incident angle and polarization of a gaussian beam. The results show that the pressure exertion on the thin film can change from pushing to pulling as the parameters are varied. In particular, we find that the direction of optical pressure can act oppositely at the different positions of the film surface in the evanescent field.

1994-11-01

434

Optical guiding measurements on the Mark III free electron laser oscillator  

International Nuclear Information System (INIS)

It has been predicted for several years that light is focused (optically guided) as well as amplified by the electron beam in a free electron laser (FEL). The degree of focusing depends strongly on both electron beam and optical beam characteristics. In an FEL oscillator the degree of focusing varies with intracavity optical power during the macropulse. We report the first direct measurements of the evolution of transverse optical model size and shape between small signal and saturation in a short wavelength (Compton regime) FEL oscillator. The mode measurements on the Mark III FEL oscillator are shown to be consistent with theory, requiring both refractive and gain contributions to guiding. (orig.).

435

Operational Experience with LHC Collimation  

CERN Document Server

A first sub-set of the collimation system has been installed for the 2008 first beam commissioning of the LHC. It included 88 collimators around the ring and the two injection lines. Each collimator has two jaws for which must be controlled and monitored with high precision. The LHC collimation system was put into operation from July to October 2008. The installed system is described and first results from system operation without and with beam are presented. It is shown that the LHC collimation system achieved the specified accuracy and reproducibility of jaw positioning. Next steps in collimation commissioning are described and planned system upgrades for high beam intensities are outlined.

2009-01-01

436

Megavoltage electron beam therapy in the treatment of basal and squamous cell carcinomata of the pinna  

Energy Technology Data Exchange (ETDEWEB)

Forty-three patients with basal and squamous cell carcinomata arising on the pinna were treated radically using a 10 MeV electron beam. The technique and dosage are described and discussed. Primary cancer control with retention of the pinna was achieved in 34 patients. Salvage pinnectomy was performed in four patients for recurrence and one patient for radiation necrosis. Two patients with large primary tumours failed to resolve and died of their disease. The advantages for the patient of the policy of primary radical electron beam therapy are discussed.

1982-05-01

437

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

438

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

439

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

440

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

441

Focused ion beam technology  

Energy Technology Data Exchange (ETDEWEB)

Focussed ion beam (FIB) technology has the advantage of being a maskless process compatible with UHV processing. This makes it attractive for use in in situ processing and has been applied to the fabrication of various mesoscopic structures. The present paper reviews these results whilst putting emphasis on in situ processing by a combined FIB and molecular beam epitaxy system. The typical performance of present FIB systems is also presented. In order to utilize the potential advantages of FIB processing, reduction of damage and improvement of throughput are important, and much effort has been devoted to developing processing techniques which require a reduced dose. The importance of low-energy FIB is discussed. (author).

1993-06-01

442

Focused ion beam technology  

International Nuclear Information System (INIS)

Focussed ion beam (FIB) technology has the advantage of being a maskless process compatible with UHV processing. This makes it attractive for use in in situ processing and has been applied to the fabrication of various mesoscopic structures. The present paper reviews these results whilst putting emphasis on in situ processing by a combined FIB and molecular beam epitaxy system. The typical performance of present FIB systems is also presented. In order to utilize the potential advantages of FIB processing, reduction of damage and improvement of throughput are important, and much effort has been devoted to developing processing techniques which require a reduced dose. The importance of low-energy FIB is discussed. (author).

443

Drug eruptions presenting at sites of prior radiation damage (sunlight and electron beam)  

Energy Technology Data Exchange (ETDEWEB)

Two patients are described in whom sunburn and electron beam radiodermatitis, respectively, were critical determinants in localizing the initial presentation of drug eruptions. In the first instance, a severe sunburn of the back and thighs was followed 7 months later by the appearance of a toxic epidermal necrolysis drug reaction to trimethoprim-sulfamethoxazole in the exact sites of the previous bullous sunburn reaction. In the second patient, a radiodermatitis of the left upper arm due to electron beam therapy for metastatic breast cancer was followed 7 weeks later by a codeine drug reaction confined to the area of the radiodermatitis. In both instances, oral rechallenge with the offending drug reproduced the eruption.

1984-07-01

444

Development of a high current negative ion source for fusion application  

Energy Technology Data Exchange (ETDEWEB)

Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.

1988-11-01

445

Detection of mice lung cancer by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).

1995-11-01

446

Comparison of the TESLA, NLC and CLIC Beam-Collimation System Performance  

CERN Document Server

This report describes studies performed in the framework of the Collimation Task Force organized to support the work of the second International Linear Collider Technical Review Committee. The post-linac beam-collimation systems in the TESLA, JLC/NLC and CLIC linear-collider designs are compared using the same computer code under the same assumptions. Their performance is quantified in terms of beam-halo and synchrotron-radiation collimation efficiency. The performance of the current designs varies across projects, and does not always meet the original design goals. But these comparisons suggest that achieving the required performance in a future linear collider is feasible.

2004-01-01

447

Collective ion acceleration by a reflexing electron beam: model and scaling. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.

1984-05-11

448

Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)  

Energy Technology Data Exchange (ETDEWEB)

Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances.

1997-08-01

449

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

450

Alopecia associated with unexpected leakage from electron cone  

Energy Technology Data Exchange (ETDEWEB)

Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

1989-06-01

451

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

452

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly ...

2008-02-15

454

Transmission electron microscopy characterisation of permalloy elements fabricated by focussed ion beam lithography  

International Nuclear Information System (INIS)

20 nm thick permalloy elements, with dimensions of 500 x 500 nm"2 and 1000 x 200 nm"2, have been fabricated on 50 nm thick silicon nitride substrate by milling using a focussed ion beam (FIB) microscope. The dose of ion beam used for the milling was varied in order to achieve the best definition for the milled areas. The FIB milled elements were characterised physically by atomic force microscopy (AFM) and bright field transmission electron microscopy (TEM) and magnetically by Fresnel imaging on a TEM modified for magnetic imaging. The FIB milled elements were found to have a more irregular edge and lower magnetic fields for events such as vortex annihilation when compared to elements of the same dimensions fabricated by conventional electron beam microscopy (EBL).

2006-02-22

455

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

456
457

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

458

The Formation of the Low-sized High Density Plasma Structures in the Self-maintained Plasma-beam Discharge  

International Nuclear Information System (INIS)

The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.

2006-01-01

459

Technique for the removal of electrons from an extracted, pulsed, H{sup {minus}} ion beam  

Energy Technology Data Exchange (ETDEWEB)

A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}

1996-10-01

460

Strongly perturbed rotational bands in the "1"8"7Ir and "1"8"9Ir  

International Nuclear Information System (INIS)

... alpha beams energy-level transitions gamma spectra iridium 187 iridium 189

1973-06-19

461

Solution of free vibration equations of semi-rigid connected Reddy?Bickford beams resting on elastic soil using the differential transform method  

British Library Electronic Table of Contents (United Kingdom)

The literature regarding the free vibration analysis of Bernoulli?Euler and Timoshenko beams under various supporting conditions is plenty, but the free vibration analysis of Reddy?Bickford beams with variable cross-section on elastic soil with/without axial force effect using the Differential Transform Method (DTM) has not been investigated by any of the studies in open literature so far. In this study, the free vibration analysis of axially loaded and semi-rigid connected Reddy?Bickford beam with variable cross-section on elastic soil is carried out by using DTM. The model has six degrees of freedom at the two ends, one transverse displacement and two rotations, and the end forces are a shear force and two end moments in this study. The governing differential equations of motion of the r...

2011-01-01

462

Smoothing of laser energy deposition by gas jets  

International Nuclear Information System (INIS)

Smoothing of laser beam non-uniformities using gas jets has been studied. The experiment has been performed with the PALS (Prague Asterix Laser System) laser working at 0.44 ?m with an intensity of about 1015 W/cm2. The laser beam has been split in two by a prism thus creating an artificial large-scale non-uniformity (? 90 ?m). We recorded time resolved and static images of laser-gas jet interaction with and without an Al target. Multi 1-dimensional and 2-dimensional simulations show that such interaction acts redistributing the over-intensities over larger surface. This effect has to be attributed to ionization processes with consequent laser beam refraction. Results show that Argon gas jet produces a strong refraction of the laser beam thus strongly reducing the initial two spots separation. (authors)

2009-08-01

463

Selection and design of ion sources for use at the Holifield radioactive ion beam facility  

Energy Technology Data Exchange (ETDEWEB)

The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for this situation, positive ion sources, in combination with charge exchange, are the ...

1994-06-01

464

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

465

Reinforced concrete beam-column joint strengthened with carbon fiber reinforced polymer  

British Library Electronic Table of Contents (United Kingdom)

An effective rehabilitation strategy is proposed to enhance the strength and stiffness of the beam-column joint in this study. An analytical model is proposed to predict the column shear of the joints strengthened with carbon fiber reinforced polymer (CFRP). Three full scale interior beam-column joints, including two specimens strengthened with CFRP and one prototype specimen, are tested in this study. The specimens are designed to represent the pre-seismic code design construction in which there is no transverse reinforcement. A new optical non-contact technique, digital image correlation (DIC), which can measure the full strain field of specimen, is used to measure and observe the full strain field of the joint. The experimental results show that the beam-column joints strengthened with ...

2010-01-01

466

RBE of the MIT Epithermal Neutron Beam for Crypt Cell Regeneration in Mice  

Science.gov (United States)

... these estimates were obtained from these and the parameter covariance matrix using a parametric bootstrap method. We present the ... ...

467

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

468

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

470

PROGRESS IN BEAM FOCUSING AND COMPRESSION FOR WARM-DENSE MATTER EXPERIMENTS  

Energy Technology Data Exchange (ETDEWEB)

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using spacecharge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has beendemonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlledramps and forced neutralization. Using an injected 30-mA K+ ion beam with initialkinetic energy 0.3 MeV, axial compression leading to ~;;50-fold current amplification andsimultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to our Neutralized Drift Compression Experiment and associated beam diagnostics that are under development to ...

2008-09-25

471

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

472

N92-22051  

Science.gov (United States)

The KDP crystal was 10 cm long and cut such that the c-axis was 50.3* to the normal of its input face. We selected for study idler and signal beams ...

473

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

474

Measurements of bragg curve for 75 MeV/u "1"2C ion beam and its inactivation effect on melanoma cells  

International Nuclear Information System (INIS)

Relative doses of 75 MeV/u "1"2C ion beam after passing through different thickness of degraders were measured with the double ionization chamber method. The degrader's thickness equalized to penetration depth of the beam in water and its Bragg curve were obtained. The measured Bragg curve is compared with that calculated based on a model set up by the authors. Meanwhile, the inactivation effect of the ion beam passing through different thickness of degraders on melanoma (B_1_6) cells was measured, and the corresponding survival fraction data for B_1_6 cells were acquired

1998-08-01

475

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.

2006-01-01

476

LHC magnet alignment  

CERN Document Server

Checks are performed on the alignment of the magnets in the LHC tunnel. It is vital that each magnet is placed exactly where it has been designed so that the path of the beam is precisely controlled.

2007-01-01

477

L. V. BALDWIN &TAL BY  

Science.gov (United States)

L. V. BALDWIN &TAL. APPARATUS FOR INCREASING ION ENGINE BEAM DENSITY. Filed Jan. 4, 1963 ... Lionel V. Baldwin. Fort Collins. Colo.. and Vid A. ...

478

Influence of ion-beam carbon-fiber surface treatment on the angle of wetting by epoxy oligomers  

International Nuclear Information System (INIS)

The influence of the regimes of modification of carbon fibers by an argon ion beam on the change in the angle of their wetting by an epoxy oligomer has been investigated. It has been shown that ion-beam treatment of carbon fibers leads to a considerable decrease in the wetting angles (the difference between the wetting angles for non modified and modified fibers is up to 32.2-38.7). Accordingly, there is also an increase in the value of the equilibrium work of adhesion by 36.2-41.6% in the contact zone. It has been established that ion-beam treatment of carbon fibers by argon ions leads to an increase in the shear strength when microplastics based on them are formed. (authors)

482

Halogens for negative ion beams and ion-ion plasmas  

International Nuclear Information System (INIS)

Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of ...

2007-07-01

483

Hadron Calorimeter Endcap  

International Science & Technology Center (ISTC)

Development of the Technology and Control of Electron-Beam Welding Procedure and Production of Full Scale Sector of Endcap CMS Hadron Calorimeter. Preparation for Mass Production.

484

Focused ion beam sculpting curved shapes.  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.

2005-02-01

485

Fabrication of nanoelectrodes for neurophysiology: cathodic electrophoretic paint insulation and focused ion beam milling  

UK PubMed Central (United Kingdom)

The fabrication and characterization of tungsten nanoelectrodes insulated with cathodic electrophoretic paint is described together with their application within the field of neurophysiology....Full Text Available

2005-09-01

486

Fabrication and characterization of low aberration micrometer-sized electron lenses  

British Library Electronic Table of Contents (United Kingdom)

Intrinsic spherical aberrations of electron lenses have been the major resolution limiting factor in electron microscopes for several decades. While effective correctors have recently been implemented, an alternative to correct these aberrations is to circumvent them by scaling down lens dimensions by several orders of magnitude. We have fabricated electrostatic lenses exhibiting one micrometer diameter apertures and evaluated their beam forming properties against predictions from numerical ray tracing simulations. It turns out that it is routinely possible to shape a paraxial low-energy electron beam by such micron-sized lenses. Beam profiles have been measured both at a distant detector as well as in a plane close to the lens. It is shown that the lens can form a parallel beam extending ...

2010-01-01

487

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron ...

1991-10-02

488

Experimental determination of a species-dependent effect in the transverse emittances of sputter-generated negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum-analyzed {sup 28}Si{sup {minus}}, {sup 58}Ni{sup {minus}}, and {sup 197}Au{sup {minus}} negative-ion beams generated by cesium-ion sputtering. The differences in the emittances are found to be principally correlated with differences in the energy spreads in the respective ion beams, which have their origins in the sputter-ejection negative-ion formation process. The experimental equipment and techniques utilized for emittance data acquisition and analysis, and evidence for a species-dependent effect in the emittances and brightnesses of the subject ion beams, are presented in this paper.

1990-02-01

489

Effects of Tapered Betafunction in the LCLS Undulators  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is an X-ray free-electron laser (FEL) project based on the SLAC linac [1]. With its nominal set of electron beam, focusing and undulator parameters, it is designed to achieve SASE saturation at an undulator length of about 100 m with an average power of 10 GW. In order to keep the electron beam focused in the undulators, a FODO lattice is integrated along the entire length of the undulators. Nominally, the quadrupole strengths are chosen to produce nearly constant betafunction and beam size along the undulator, optimized for the FEL interaction in the exponential growth regime. Since these quadrupoles are electromagnetic, it is possible to adjust the individual quadrupole strength to vary the betafunction and the beam size along the undulator, tailoring the FEL interaction in the start-up and the saturation regimes. In this paper, we present simulation studies of ...

2005-09-30

490

Effect of helium and hydrogen production on irradiation hardening of F82H steel irradiated by ion beams  

International Nuclear Information System (INIS)

Effects of helium and hydrogen production on irradiation hardening of martensitic steel F82H (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) were examined by dual or triple beam experiments. The effects of tempering and cold working were also examined. The irradiations were performed at about 500degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The value of appm-He/dpa for the dual ion beams was about 15, and the values of appm-He/dpa and appm-H/dpa for the triple ion beams were 15 and 15 (or 150), respectively. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. Irradiation softening and hardening was observed in F82H-std, F82H+20%CW and a non-tempered F82H steels irradiated at about 500degC to 18 and 50 dpa, respectively, by dual ion ...

2007-06-01

491

Direct energy recovery with ac electric power output  

Energy Technology Data Exchange (ETDEWEB)

A concept of direct energy recovery system applying an alternating or rotating magnetic field is proposed for a negative-ion-based neutral beam injection system (NNB) to heat a plasma and/or drive a plasma current in a fusion reactor. Nearly same amounts of residual positive and negative hydrogen-isotope ion beams with beam energy of {approx}1 MeV are produced in an NNB using a gas neutralizing cell. Consequently, a recovered energy is obtained directly in the form of ac electric power, if these positive- and negative-ion beams are alternated or rotated and introduced to two or more recovery electrodes in turn by an alternating or rotating magnetic field. This concept will greatly reduce a technological difficulty in regeneration of a recovered electric energy with such a very high voltage. (author).

1994-12-31

492

DESIGN, MANUFACTURE, DEVELOPMENT, TEST, AND EVALUATION OF BORON ...  

Science.gov (United States)

the shear-beam design and the larger scale component test specimen. The subcompo - nents designed were: a. Web splice specimen. ...

493

DARPA - Advanced Composite Materials Annual Presentation ...  

Science.gov (United States)

... 66. BV Sankar and MA Pinheiro, "An Offset Beam Finite Element for Fracture Analysis of Delaminations," AIAA Paper Number 90-1024-CP, 31st ...

1992-11-20

494

Conceptual design of industrial free electron laser using superconducting accelerator  

International Nuclear Information System (INIS)

Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.

1995-08-21

495

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

496

A report on collective ion acceleration via space charge waves on intense relativistic electron beams  

Science.gov (United States)

Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.

1981-02-01