WorldWideScience
 
 
1

Magnetic susceptibility of Cesub(x)Lasub(1-x)B_6, Cesub(x)Eusub(1-x)B_6, Smsub(x)Lasub(1-x)B_6, and Smsub(x)Cesub(1-x)B_6 solid solutions  

International Nuclear Information System (INIS)

The magnetic susceptibility chi of Cesub(x)Lasub(1-x)B_6, Cesub(x)Eusub(1-x)B_6, Smsub(x)Lasub(1-x)B_6, and Smsub(x)Cesub(1-x)B_6 is investigated for temperatures of 80 to 1000 K. chi of Cesub(x)Lasub(1-x)B_6 and Cesub(x)Eusub(1-x)B_6 obeys the Curie-Weiss law. The composition dependence of effectiv magnetic moment #mu#sub(eff) exhibits an unusual behaviour. The value of #mu#sub(eff) per cerium ion abruptly decreases on substituting the cerium ions in CeB_6 by lanthanium ions. The values of the Weiss constants agree with the conclusions of the RKKY theory of indirect exchange by conduction electrons. The temperature dependence of chi of Smsub(x)Lasub(1-x)B_6 and Smsub(x)Cesub(1-x)B_6 do not obey the Curie-Weiss law. Both magnetic and X-ray data show that in Smsub(x)Lasub(1-x)B_6 and ...

1980-11-01

2

Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...

2011-01-01

3

Management of Concomitant Cancer and Abdominal Aortic Aneurysm  

UK PubMed Central (United Kingdom)

Background. The coexistence of neoplasm and abdominal aortic aneurysm (AAA) presents a real management challenge. This paper reviews the literature on the prevalence, diagnosis,...Full Text Available

4

Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography  

UK PubMed Central (United Kingdom)

AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available

2008-10-01

5

lla3362k.334  

Science.gov (United States)

... dWUpkVaqnnd`dcXegkjcncllYck^uWcmfiebvqqhdydlf_kt`bgn^atdWm Uhw^kb]~\\peg ui\\[ n`XmRV[VY^YbSO`\\x nZZW_`fXrnhpb]fo_madl^_^Wc sg~\\tmjXb]l_^jrekioohc[hbcfcxm ...

6

Transforming growth factor-beta signaling in thoracic aortic aneurysm development: a paradox in pathogenesis  

UK PubMed Central (United Kingdom)

Thoracic aortic aneurysms (TAAs) are potentially devastating, and due to their asymptomatic behavior, pose a serious health risk characterized by the lack of medical treatment options and high...Full Text Available

2009-01-01

7

Transcatheter stent implantation to treat aortic coarctation in infancy.  

UK PubMed Central (United Kingdom)

A ten week old girl who had previously undergone a palliative procedure for the hypoplastic left heart syndrome had unrelieved aortic coarctation that did not respond to standard balloon dilatation....Full Text Available

1993-01-01

8

Stimulation of albumin endocytosis by cationized ferritin in cultured aortic smooth muscle cells.  

UK PubMed Central (United Kingdom)

Anionic microdomains within the aortic smooth muscle cell (SMC) surface glycocalyx represent a potential barrier to the endocytosis of anionic plasma proteins. Cultured SMCs exposed briefly to cationized...Full Text Available

1985-12-01

9

Radiographic monitoring of incidental abdominal aortic aneurysms: a retrospective population-based cohort study  

UK PubMed Central (United Kingdom)

BackgroundAn abdominal aortic aneurysm (AAA) that is identified when the abdomen is imaged for some other reason is known as an incidental AAA. No population-based studies have...Full Text Available

10

Progress in Treatment of Thoracoabdominal and Abdominal Aortic Aneurysms Involving Celiac, Superior Mesenteric, and Renal Arteries  

UK PubMed Central (United Kingdom)

This is a report of surgical treatment of thoracoabdominal aortic aneurysms and aneurysms of the abdominal aorta from which the visceral vessels arise during the 18 year period from April 5, 1960,...Full Text Available

1978-09-01

11

Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study  

UK PubMed Central (United Kingdom)

The aim of this study was to compare the hemodynamic and ventilatory effects of prolonged infrarenal aortic cross-clamping in pigs undergoing either laparotomy or laparoscopy. 18 pigs were used for...Full Text Available

2008-01-01

12

Neuronatin: A New Inflammation Gene Expressed on the Aortic Endothelium of Diabetic Mice  

UK PubMed Central (United Kingdom)

OBJECTIVE—Identification of arterial genes and pathways altered in obesity and diabetes.RESEARCH DESIGN AND METHODS—Aortic gene expression profiles of...Full Text Available

2008-10-01

13

Temporary endovascular control of a bleeding aortoenteric fistula by transcatheter coil embolization.  

Science.gov (United States)

A 67-year-old man presented with gastrointestinal bleeding resulting from a fistula between the aortic stump and the fourth part of the duodenum 14 months after an axillobifemoral bypass, graft excision, and aortic stump closure for aortic graft infection. The patient initially refused any attempt at definitive surgical treatment so coil embolization of the aortic stump was performed via a brachial approach. Coil embolization may be a useful adjunct in the management of such difficult problems. This approach may buy time and allow careful planning of a definitive treatment or may serve as a palliative procedure in inoperable patients. PMID:15947052

2005-06-01

14

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ...

15

T lymphocytes in aortic and coronary intimas. Their potential role in atherogenesis.  

UK PubMed Central (United Kingdom)

In order to investigate the role of mononuclear cells in infiltrates during the initial stages of atherogenesis, the authors have studied by immunohistochemical methods the aortas and coronary vessels...Full Text Available

1988-02-01

16

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

17

Association Between Wasted Pressure Effort and Left Ventricular Hypertrophy in Hypertension: Influence of Arterial Wave Reflection  

British Library Electronic Table of Contents (United Kingdom)

BackgroundWave reflection during the systole increases left ventricular (LV) pressure, tension-time index (TTI) and myocardial oxygen requirement. The purpose of this study was to extract that component of extra myocardial oxygen requirement that is due to early systolic wave reflection, define it as wasted effort (?Ew), and examine its relationship to LV hypertrophy (LVH).MethodsRadial artery pressure waveforms were recorded using applanation tonometry and central aortic waveforms generated in 98 patients with untreated hypertension. Aortic augmentation index (AIa), wave reflection amplitude (i.e., aortic augmented pressure (AG)) and systolic duration (ED?Tr), ejection duration (ED) and round-trip travel time of the pressure wave (Tr) were calculated from the aortic waveform, a...

2008-01-01

18

lue0558c.185  

Science.gov (United States)

P G.2@_ kuD} }mkvhy K=\\v|y vp|u QO[gj}ca njVT{ npaL]bs tswg t6Om p\\[.* rWfpqe zkpt yoJX nZtz Qa"q %&'()*456789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz Etq= $X'b ...

19

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

20

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

 
 
 
 
21

Left Main Coronary Stenosis as a Consequence of Bentall Operation: Percutaneous Treatment  

UK PubMed Central (United Kingdom)

A 65-year-old man suffering from ascending aorta aneurysm and atherosclerotic three vessel disease without left main involvement underwent aortic root replacement with coronary ostia reimplantation...Full Text Available

2009-01-01

22

Evidence that cell surface heparan sulfate is involved in the high affinity thrombin binding to cultured porcine aortic endothelial cells.  

UK PubMed Central (United Kingdom)

It has been postulated that thrombin binds to endothelial cells through, at least in part, cell surface glycosaminoglycans such as heparan sulfate, which could serve as antithrombin cofactor on the...Full Text Available

1985-04-01

23

Effect of aortic valvular regurgitation upon the impedance cardiogram.  

UK PubMed Central (United Kingdom)

The first derivative thoracic impedance cardiogram, phonocardiogram, and electrocardiogram were recorded in three groups of 22 subjects each. In Group 1 (control), simultaneous impedance cardiogram,...Full Text Available

1978-09-01

24

Chylopericardium after cardiac surgery can be treated successfully by oral dietary manipulation: a case report  

UK PubMed Central (United Kingdom)

We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available

25

Both common and specialty mushrooms inhibit adhesion molecule expression and in vitro binding of monocytes to human aortic endothelial cells in a pro-inflammatory environment  

UK PubMed Central (United Kingdom)

BackgroundCardiovascular disease (CVD) is a leading cause of mortality in the United States as well as globally. Epidemiological studies show that regular fruit and vegetable consumption...Full Text Available

26

Acute aortic thrombosis in patients receiving cisplatin-based chemotherapy  

UK PubMed Central (United Kingdom)

The increased risk of thrombosis in patients with active cancer has multiple causes. Acute thrombosis of the aorta is an exceedingly rare but potentially devastating complication in patients with cancer...Full Text Available

2011-04-01

27

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. ...

2000-09-01

28

Evolution of surfaces properties for 100Cr6 steel by implantation and ionic mixing; Evolution des proprietes de surface de l`acier 100Cr6 par implantation et melange ioniques  

Energy Technology Data Exchange (ETDEWEB)

Physico-chemical characterizations performed on samples of 100Cr6 steel implanted both with boron and nitrogen revealed the formation of boron nitride along with the following new phases: Fe{sub 1-x}(B, N), Fe{sub 2-x}(B, N) and Fe{sub 3-x}(B, N). A thorough analysis of boron NITRIDE (5BN) indicates that a low ion current density (3 {mu}A.cm{sup -2}) in the case of the boron plus nitrogen sequence favours the formation of sp{sup 2} bonds (hexagonal-BN) while a higher ion current density (6{mu}A.cm{sup -2}) promotes sp{sup 3} bonds (cubic-BN) in the opposite sequence. Tribological tests carried out on these samples revealed that nitrogen and boron implantations do not lead to any significant improvement of friction and wear at variance with the results obtained by others authors. However, on a set samples accidentally contaminated with carbon during implantation, we noticed a considerable improvement of these tribological ...

1996-07-09

29

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a ...

30

Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement  

British Library Electronic Table of Contents (United Kingdom)

BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...

2011-01-01

31

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion ...

32

Oxidation, Volatilization, and Redistribution of Molybdenum from TZM Alloy in Air  

Energy Technology Data Exchange (ETDEWEB)

The excellent high temperature strength and thermal conductivity of molybdenum-base alloys provide attractive features for components in advanced magnetic and inertial fusion devices. Refractory metal alloys react readily with oxygen and other gases. Oxidized molybdenum in turn is susceptible to losses from volatile molybdenum trioxide species, (MoO3)m, in air and the hydroxide, MoO2(OH)2, formed from water vapor. Transport of radioactivity by the volatilization, migration, and re-deposition of these volatile species during a potential accident involving a loss of vacuum or inert environment represents a safety issue. In this report we present experimental results on the oxidation, volatilization and re-deposition of molybdenum from TZM in flowing air between 400 and 800°C. These results are compared with calculations obtained from a vaporization mass transfer model using chemical thermodynamic data for vapor pressures of MoO3(g) over pure solid MoO3 and ...

2000-01-01

33

Infinite bubbling in non-K\\"ahlerian geometry  

CERN Document Server

In a holomorphic family $(X_b)_{b\\in B}$ of non-K\\"ahlerian compact manifolds, the holomorphic curves representing a fixed 2-homology class do not form a proper family in general. The deep source of this fundamental difficulty in non-K\\"ahler geometry is the {\\it explosion of the area} phenomenon: the area of a curve $C_b\\subset X_b$ in a fixed 2-homology class can diverge as $b\\to b_0$. This phenomenon occurs frequently in the deformation theory of class VII surfaces. For instance it is well known that any minimal GSS surface $X_0$ is a degeneration of a 1-parameter family of simply blown up primary Hopf surfaces $(X_z)_{z\\in D\\setminus\\{0\\}}$, so one obtains non-proper families of exceptional divisors $E_z\\subset X_z$ whose area diverge as $z\\to 0$. Our main goal is to study in detail this non-properness phenomenon in the case of class VII surfaces. We will prove that, under certain technical assumptions, a lift $\\widetilde E_z$ of $E_z$ in the ...

2010-01-01

34

Effect of Li-Al co-doping on the energy gaps of MgB2  

International Nuclear Information System (INIS)

We studied the effects of co-doping with Li and Al on the energy gaps of MgB2 by performing point-contact Andreev-reflection spectroscopy (PCAR) in polycrystalline Mg1-x(Al?Li1-?)xB2 samples with x?0.4. Even though the lattice parameters and the critical temperature of the compound simply scale with the effective Al content ?x, irrespective of the Li concentration, the energy gaps do not. In particular, for a given effective Al content, the comparison with Mg1-y(Al)yB2 with y = ?x shows that the ? bandgap is practically the same while the ? bandgap is higher. A clear gap merging is observed in the most doped sample (x = 0.4) when Tc<20 K. The results are discussed within the two-band Eliashberg theory and compared to the outcomes of first-principles calculations of the effects of Li and Al co-doping on the electronic structure of magnesium diboride.

2009-02-01

35

CT of blunt chest trauma in children  

Energy Technology Data Exchange (ETDEWEB)

While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. Children demonstrating findings incidental to the actual injury yet important to the ...

1993-03-01

36

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: ...

2010-01-01

37

Anesthesia Technique and Outcomes of Endovascular Aneurysm Repair  

British Library Electronic Table of Contents (United Kingdom)

Anesthetic techniques vary widely in the endovascular repair of abdominal aortic aneurysms (EVAR). Previous studies have demonstrated the feasibility of using local anesthesia. However, the ideal anesthetic technique has not been determined. This study examines whether anesthesic technique influences the outcomes of EVAR. Data regarding demographics, risk factors, procedural characteristics, recovery characteristics, treatment complications, acute ( 0.05, ANOVA). From these results we concluded that EVAR with local anesthesia is a safe and efficacious method that may reduce recovery times and postoperative medical morbidity compared to use of genera1 or spinal/epidural anesthesia.

2005-01-01

38

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich als Alternative zur ...

2008-09-15

39

Vascular ATP-sensitive potassium channels are over-expressed and partially regulated by nitric oxide in experimental septic shock  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the activation and expression of vascular (aorta and small mesenteric arteries) potassium channels during septic shock with or without modulation of the NO pathway. Methods Septic shock was induced in rats by peritonitis. Selective inhibitors of vascular KATP (PNU-37883A) or BKCa [iberiotoxin (IbTX)] channels were used to demonstrate their involvement in vascular hyporeactivity. Vascular response to phenylephrine was measured on aorta and small mesenteric arteries mounted on a wire myograph. Vascular expression of potassium channels was studied by PCR and Western blot, in the presence or absence of 1400W, an inducible NO synthase (iNOS) inhibitor. Aortic activation of the transcriptional factor nuclear factor-kappaB (NF-?B) was assessed by electrophoretic mobility shift as...

2011-01-01

40

The value of cardiac catheterization and cineangiography in infantile lobar emphysema  

International Nuclear Information System (INIS)

Lobar emphysema is an uncommon cause of respiratory distress in infancy. Congenital heart disease is seen in about 20% of the patients with infantile (congenital) lobar emphysema. We described six infants with lobar emphysema. In three of them a congenital heart disease was demonstrated by cardiac catheterization and cineangiography; two had a tetralogy of Fallot with right aortic arch and the third infant a ventricular septal defect. The pulmonary angiography showed stretching of the arteries with very poor filling of the peripheral arteries and a characteristic smaller pulmonary vein in the affected lobe. In all the six patients the pulmonary artery pressure was normal. All the patients underwent lobectomy with good results. We feel that a preoperative cardiac catheterization and cineangiography is of value in this very sick group of infants. (orig.).

 
 
 
 
41

The chance finding of an aneurysm of the right sinus of Valsalva in an 11-year-old child with a ventricular septal defect and a pericardial effusion  

British Library Electronic Table of Contents (United Kingdom)

Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...

2011-01-01

42

RIFLE Criteria for Cardiac Surgery-Associated Acute Kidney Injury: Risk Factors and Outcomes  

British Library Electronic Table of Contents (United Kingdom)

The aims of this study were to identify risk factors and evaluate the association with clinical outcomes of postoperative cardiac surgery-associated acute kidney injury (CSA-AKI). Data from 2488 consecutive adult patients were analyzed. Patients were classified as having CSA-AKI based on the risk, injury, failure, loss of kidney function, and end-stage kidney disease (RIFLE) criteria using peak postoperative creatinine in the postoperative intensive care unit (ICU). Multiple stepwise logistic regression analysis was used to identify independent risk factors for CSA-AKI. CSA-AKI occurred in 584 patients (23.5%). CSA-AKI patients had significantly longer aortic cross-clamp and cardiopulmonary bypass times. Furthermore, CSA-AKI patients had higher hospital mortality (5.5% vs 1.5%, PCopyright2...

2010-01-01

43

Quantification of the thrombogenicity of Dacron aortic prostheses  

International Nuclear Information System (INIS)

Eight patients with double-velour Dacron aorto-femoral grafts implanted for 2-60 months were studied. Indium-111-labelled platelets were found to have a shortened mean platelet lifespan (MPLS) of 138 +- 32 hours compared with the normal platelet lifespan of 224 +- 23 hours. Labelled platelets accumulated on all grafts, irrespective of graft age, to a maximum of 1,80 +- 0,83% of whole body radioactivity; thereafter graft radio-activity decreased. This suggests that platelets on the graft are in dynamic equilibrium with those in the circulation. Platelets may be lost from the graft by embolization or radioactivity may be released because of platelet lysis. Although MPLS may depend on the age and surface area of the graft, concomitant arterial disease probably also contributes to the shortened MPLS.

44

Helical CT of traumatic injuries of the thoracic aorta; Applicazioni della Tomografia Computerizzata spirale nello studio delle lesioni traumatiche dell'aorta toracica  

Energy Technology Data Exchange (ETDEWEB)

Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 ...

2000-09-01

45

Functional Characterization of Melanocyte Stem Cells in Hair Follicles.  

Science.gov (United States)

In mice, coat pigmentation requires a stem cell (SC) system in which the survival, proliferation, and differentiation of melanocytes (MCs) are regulated by microenvironments in hair follicles (HFs). In vitro systems are required to analyze the behavior of single melanocyte stem cells (MCSCs) and their potential to form SC systems in vivo. We describe here an experimental system for the isolation, self-renewal, and differentiation of MCSCs, as well as an in vivo reconstitution assay for assessing their potential. Using Dct(tm1(Cre)Bee)/CAG-CAT-GFP mice, we show that, in the presence of stem cell factor and basic fibroblast growth factor and the XB2 feeder cell line, purified MCSCs can undergo clonogenic proliferation, resulting in c-Kit(low) side scatter(low) cells. In culture, these cells maintain their capacity to differentiate and reconstitute an MCSC system in HFs. As these cells are present in the upper part of the HF near the bulge region, express only low ...

2011-07-14

46

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...

2003-07-01

47

Long-Term Follow-Up of Percutaneous Balloon Angioplasty in Adult Aortic Coarctation  

International Nuclear Information System (INIS)

Purpose: To assess long-term outcomes following percutaneous transluminal angioplasty (PTA) of congenital aortic coarctation in adults.Methods: Seventeen patients underwent PTA for symptomatic adult coarctation of the aorta. Sixteen patients, with a mean age of 28 years (range 15-60 years), were reviewed at a mean interval after angioplasty of 7.3 years (range 1.5-11 years). Assessment included magnetic resonance imaging (MRI), Doppler echocardiography, and clinical examination. Current clinical measurements were compared with pre- and immediate post-angioplasty measurements.Results: At follow-up 16 patients were alive and well. The patient not included in follow-up had undergone surgical repair and excision of the coarctation segment following PTA. Mean brachial systolic blood pressure for the group decreased from 174 mmHg before angioplasty to 130 mmHg at follow-up (p 0.0001). The mean gradient had fallen significantly from 50.9 to 17.8 at follow-up (p = 0.001). ...

2000-09-01

48

Altered glycosaminoglycan metabolism in injured arterial wall  

Energy Technology Data Exchange (ETDEWEB)

Glycosaminoglycans (GAG) are believed to be important in the pathogenesis of atherosclerosis. We have previously demonstrated that areas of injured aorta that have been re-endothelialized accumulate increased amounts of lipid and GAG when compared to areas remaining de-endothelialized. We have now examined the net incorporation of labeled precursors into the individual GAG present in both re-endothelialized and de-endothelialized areas of rabbit aorta. Aortic tissue was examined at 2-3 and 10-14 weeks after a denuding injury by incubating tissue minces with (/sup 3/H)glucosamine and sodium (/sup 35/S)sulfate for 24 hr. Following incubation, the aortic GAG were isolated and assayed for uronic acid concentration and radioactivity. Results indicate that the total GAG concentration was significantly greater in the re-endothelialized as compared to de-endothelialized areas. The concentration in uninjured aorta was 9.01. The difference between the ...

1985-06-01

49

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?  

International Nuclear Information System (INIS)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-01-01

50

Salicylate Treatment Improves Age-Associated Vascular Endothelial Dysfunction: Potential Role of Nuclear Factor kB and Forkhead Box O Phosphorylation  

British Library Electronic Table of Contents (United Kingdom)

We hypothesized that I kappa B kinase (IKK)-mediated nuclear factor kappa B and forkhead BoxO3a phosphorylation will be associated with age-related endothelial dysfunction. Endothelium-dependent dilation and aortic protein expression/phosphorylation were determined in young and old male B6D2F1 mice and old mice treated with the IKK inhibitor, salicylate. IKK activation was greater in old mice and was associated with greater nitrotyrosine and cytokines. Endothelium-dependent dilation, nitric oxide (NO), and endothelial NO synthase phosphorylation were lower in old mice. Endothelium-dependent dilation and NO bioavailability were restored by a superoxide dismutase mimetic. Nuclear factor kappa B and forkhead BoxO3a phosphorylation were greater in old and were associated with increased express...

2011-01-01

51

Micropatterned polysaccharide surfaces via laser ablation for cell guidance  

Energy Technology Data Exchange (ETDEWEB)

Micropatterned materials were obtained by a controlled laser ablation of a photoimmobilised homogeneous layer of hyaluronic acid (Hyal) and its sulphated derivative (HyalS). The photoimmobilisation was performed by coating the polysaccharide, adequately functionalised with a photoreactive group, on aminosilanised glass substrate and immobilising it on the surface under UV light. Hyal or HyalS photoimmobilised samples were then subjected to laser ablation with wavelengths in the UV regions in order to drill the pattern. Four different patterns with stripes of 100, 50, 25 and 10 {mu}m were generated. A chemical characterisation by attenuated total reflection/Fourier transform infrared (ATR/FT-IR) and time of flight-secondary ions mass spectrometry (TOF-SIMS) confirmed the success of the laser ablation procedure and the presence of alternating stripes of polysaccharide and native glass. The exact dimensions of the stripes were determined by atomic force microscopy. The analysis of cell ...

2003-03-03

52

Effects of chronic treatment with honokiol in spontaneously hypertensive rats.  

Science.gov (United States)

The present study was performed to evaluate the antihypertensive effects of honokiol in vivo in spontaneously hypertensive rats (SHR). The effects of honokiol were investigated by determination of the blood pressure, vascular reactivity, oxidative parameters, and histologic change in the aorta. Long-term administration of honokiol (400 mg/kg/d) to SHR decreased systolic blood pressure significantly. Honokiol (200, 400 mg/kg/d) enhanced the aortic relaxation in response to acetylcholine after 49-d treatment, but had no significant effects on the relaxation to sodium nitroprusside. The oral administration of honokiol significantly increased the plasma level of NO(2(-))/NO(3(-)), but decreased the level of malondialdehyde in liver of SHR compared with the control vehicle. In addition, SHR administered honokiol showed significant reductions in the elastin bands and media thickness in the aorta. These results suggest that chronic treatment with honokiol exerts an ...

2010-01-01

53

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...

2009-04-15

54

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT ...

1997-01-01

55

Cell behaviour on chemically microstructured surfaces  

Energy Technology Data Exchange (ETDEWEB)

Micropatterned surfaces with different chemical topographies were synthesised in order to investigate the influence of surface chemistry and topography on cell behaviour. The microstructured materials were synthesised by photoimmobilising natural Hyaluronan (Hyal) and its sulphated derivative (HyalS), both adequately functionalised with a photorective moiety, on glass substrates. Four different grating patterns (10, 25, 50 and 100 {mu}m) were used to pattern the hyaluronan. The micropatterned samples were analysed by Secondary Ions Mass Spectrometry, Scanning Electron Microscopy (SEM) and Atomic Force Microscopy to investigate the chemistry and the topography of the surfaces. The spectroscopic and microscopic analysis of the microstructured surfaces revealed that the photoimmobilisation process was successful, demonstrating that the photomask patterns were well reproduced on the sample surface. The influence of chemical topographies on the cell behaviour was then analysed. Human and ...

2003-03-03

56

The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent  

Energy Technology Data Exchange (ETDEWEB)

To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ...

2008-05-15

57

The crescent and the periluminal halo: Two Computed Tomography signs of aortic aneurysm impending rupture?; La semiluna e l`alone periluminale: Due segni con Tomografia Computerizzata di aneurisma aortico a rischio di rottura?  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo had the same frequency in the 2 groups (12.5 % and 9.5 %). Both signs were more ...

1997-04-01

58

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

59

Intestinal circulation during inhalation anesthesia  

Energy Technology Data Exchange (ETDEWEB)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of /sub 86/Rb and 9-microns spheres labeled with /sup 141/Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. Halothane, enflurane, ...

1985-04-01

60

Intestinal circulation during inhalation anesthesia  

International Nuclear Information System (INIS)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of _8_6Rb and 9-microns spheres labeled with "1"4"1Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. Halothane, enflurane, and ...

 
 
 
 
61

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January through December 1984 were analized. 90 % of ...

1984-12-01

62

Corrected transposition of the great arteries  

International Nuclear Information System (INIS)

The corrected transposition of the great arteries is an usual congenital cardiac malformation, which consists of transposition of great arteries and ventricular inversion, and which is caused by abnormal development of conotruncus and ventricular looping. High frequency of associated cardiac malformations makes it difficult to get accurate morphologic diagnosis. A total of 18 cases of corrected transposition of the great arteries is presented, in which cardiac catheterization and angiocardiography were done at the Department of Radiology, Seoul National University Hospital between September 1976 and June 1981. The clinical, radiographic, and operative findings with the emphasis on the angiocardiographic findings were analyzed. The results are as follows: 1. Among 18 cases, 13 cases have normal cardiac position, 2 cases have dextrocardia with situs solitus, 2 cases have dextrocardia with situs inversus and 1 case has levocardia with situs inversus. 2. Segmental sets are (S, L, L) in 15 ...

1981-12-01

63

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...

1991-01-01

64

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...

2002-05-01

65

Transpositions and malpositions of the great arteries  

International Nuclear Information System (INIS)

The transposition of the great arteries afters to an abnormal connection and relation of the great arteries in which the aorta arises from the morphologic right ventricle and the pulmonary artery from the morphologic left ventricle, while the malposition of the great arteries indicates an abnormal relationship between the great arteries in which the great arteries are not transposed across the ventricular septum but they are malposed, as is seen in double outlet right ventricle, double outlet left ventricle and single ventricles. Transpositions and malpositions of the great arteries are understood as a spectrum of malformation caused by abnormal conal development and can be included in the common category of 'conotruncal malpositions'. Authors analized 32 cases of transpositions and malpositions of the great arteries in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 17 months, with specific references to the ...

1980-12-01

66

Computed tomography of the mediastinal lesion  

Energy Technology Data Exchange (ETDEWEB)

Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower densities were seen in ...

1984-09-15

67

The angiogram sign in pulmonary atelectasis studied with helical Computed Tomography. Incidence and value; Il segno dell'angiogramma nelle atelettasie polmonari studiate con Tomografia Computerizzata spirale. Incidenza e validita' semeiologica  

Energy Technology Data Exchange (ETDEWEB)

In this issue it has been investigated the yield of Helical CT in the study of lung vessels, the incidence of the angiogram sign and its actual value. July 1997 to December 1998, were studied 30 cases of pulmonary collapse of different origin. It was found 15 cases of passive collapse (10 from pleural effusion, 2 from diaphragmatic compression, 2 from traumatic pneumothorax, and 1 from isthmic aortic aneurysm), 12 cases of obstructive collapse (9 from bronchogenic carcinoma, 1 from mucoid obstruction, 1 from ilar lymphadenopathy, and 1 from mediastinal cancer), 2 cases of adhesive collapse and 1 case of round atelectasis. All the examinations were performed with the Helical technique during nonionic iodinated contrast agent injection (bolus, 300-350 mg/mL); it was used an automatic injector set at 2-3 mL/s. It was studied the images for the angiogram sign, that is hyperdense bands, usually longer than 2 cm, through the collapsed lung, which correspond to normal ...

1999-12-01

68

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and ...

2002-10-01