WorldWideScience
1

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

2

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. ...

2008-02-01

3

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of ...

2005-01-01

4

Investigating the complex X-ray spectrum of a broad-line 2MASS red quasar: XMM-Newton observation of FTM 0830+3759  

CERN Document Server

We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of ...

2010-01-01

5

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

6

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

7

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

8

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and ...

2002-03-01

9

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

10

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

11

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

12

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively ...

2008-01-01

13

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

14

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

15

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

16

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

17

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in ...

2007-01-01

18

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

19

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single ...

1998-10-01

20

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...

2001-01-01

21

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

22

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase ...

2009-07-01

23

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

24

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

25

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The ...

1993-08-01

27

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

28

Establishing a Connection Between Active Region Outflows and the Solar Wind: Abundance Measurements with EIS/Hinode  

CERN Document Server

One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December ...

2010-01-01

29

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source ...

1989-02-14

30

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

31

Coupling of Pressure-Induced Structural Shifts to Spectral Changes in a Yellow Fluorescent Protein  

UK PubMed Central (United Kingdom)

AbstractX-ray diffraction analysis of pressure-induced structural changes in the Aequorea yellow fluorescent protein Citrine reveals the structural basis for the continuous...Full Text Available

2009-09-16

32

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

33

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

34

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove ...

2007-08-21

35

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the ...

2007-08-21

36

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, ...

2010-01-01

37

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and ...

2005-01-01

38

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting ...

2010-06-01

39

The Orbit of the Eclipsing X-ray Pulsar EXO 1722-363  

CERN Document Server

With recent and archival Rossi X-Ray Timing Explorer (RXTE) X-ray measurements of the heavily obscured X-ray pulsar EXO 1722-363 (IGR J17252-3616), we carried out a pulse timing analysis to determine the orbital solution for the first time. The binary system is characterized by a_x sin(i) = 101 +/- 3 lt-s and P_orb = 9.7403 +/- 0.0004 days (90% confidence), with the precision of the orbital period being obtained by connecting datasets separated by more than 7 years (272 orbital cycles). The orbit is consistent with circular, and e 61 degrees at the 99% confidence level, the radius of the primary is between 21 R_sun and 37 R_sun, and its mass is less than about 22 M_sun. The acceptable range of radius and mass shows that the primary is probably a supergiant of spectral type B0I-B5I. Photometric measurements of its likely counterpart are consistent with the spectral type and ...

2006-01-01

40

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase ...

2009-09-01

41

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

42

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

43

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

44

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

45

Star Formation Activities of Galaxies in the Large-Scale Structures at z=1.2  

CERN Document Server

Recent wide-field imaging observations of the X-ray luminous cluster RDCSJ1252.9-2927 at z=1.24 uncovered several galaxy groups that appear to be embedded in filamentary structure extending from the cluster core. We make a spectroscopic study of the galaxies in these groups using GMOS on Gemini-South and FORS2 on VLT with the aim of determining if these galaxies are physically associated to the cluster. We find that three groups contain galaxies at the cluster redshift and that they are probably bound to the cluster. This is the first confirmation of filamentary structure as traced by galaxy groups at z>1. We then use several spectral features in the FORS2 spectra to determine the star formation histories of group galaxies. We find a population of relatively red star-forming galaxies in the groups that are absent from the cluster core. While similarly red star forming galaxies can also be found in the field, the average ...

2009-01-01

46

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

47

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

48

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

49

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector ...

1992-10-01

50

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...

2005-07-12

51

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point ...

2008-12-15

52

ROSAT observations of the RSCVn binary sigma Geminorum  

DEFF Research Database (Denmark)

X-ray observations of the RSCVn system sigma Geminorum have been undertaken with the ROSAT observatory. Several spectra of very good signal-to-noise ratio were obtained. Spectral fitting using metal abundances amounting to 50% of solar values reveal two temperature components at 2 MK and 12 MK. Previous EXOSAT observations showed another component at 40 MK. Particular interest is focused on the temporal variations of the X-ray emission. It is found that variations occur on time scales ranging from years to hours and minutes.

1997-01-01

53

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

54

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. ...

2006-08-01

55

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

56

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

57

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

58

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

59

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change ...

2006-06-19

60

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...

2005-04-17

61

Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam  

International Nuclear Information System (INIS)

Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images ...

1999-05-21

62

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. ...

1996-12-31

63

The impact of accretion disk winds on the X-ray spectrum of AGN: Part 1 - XSCORT  

CERN Document Server

(abridged) The accretion disk in AGN is expected to produce strong outflows, in particular a UV-line driven wind. Despite providing a good fit to the data, current spectral models of the X-ray spectrum of AGN observed through an accretion disk wind are ad-hoc in their treatment of the properties of the wind material. In order to address these limitations we adopt a numerical computation method that links a series of radiative transfer calculations, incorporating the effect of a global velocity field in a self-consistent manner (XSCORT). We present a series of example spectra from the XSCORT code that allow us to examine the shape of AGN X-ray spectra seen through a wind, for a range of velocity and density distributions, total column densities and initial ionization parameters. These detailed spectral models clearly show considerable complexity and structure that is strongly affected by all these ...

2007-01-01

64

Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state  

CERN Document Server

We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not ...

2010-01-01

65

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

66

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography ...

2001-01-01

67

Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+  

British Library Electronic Table of Contents (United Kingdom)

The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...

2009-01-01

68

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

69

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production ...

1981-10-01

70

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

71

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

72

Microstructures for high-energy x-ray and particle-imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-05-01

73

Microstructures for high-energy x-ray and particle imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-11-01

74

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

75

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

76

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

77

Dual-energy projection radiography using condenser discharge x-ray generator and FCR. Determination of technical factors  

Energy Technology Data Exchange (ETDEWEB)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.

1987-04-01

78

Dual-energy projection radiography using condenser discharge x-ray generator and FCR  

International Nuclear Information System (INIS)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).

1987-01-01

80

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

81

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

82

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

83

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

84

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...

2001-04-01

85

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...

2001-04-01

86

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...

87

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

88

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

89

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

90

Synthesis, spectral and X-ray structural studies of a NO donor Schiff base ligand and its Ni(II) complexes  

British Library Electronic Table of Contents (United Kingdom)

The Schiff base ligand, 4-isopropylbenzaldehyde[N-(3-oxo-3,4-dihydro-2-quinoxalinyl)hydrazone] (Ipbh), the 1:1 condensation product of 4-isopropylbenzaldehyde and 2-hydroxy-3-hydrazinoquinoxiline, has been synthesized and characterized by X-ray crystallography. A series of complexes of Ipbh with Nickel(II), viz., [Ni(Ipbh)2]Cl2 (1), [Ni(Ipbh)2]Br2 (2), [Ni(Ipbh)2]I2 (3), [Ni(Ipbh)2(CH3OH)2](NO3)2(CH3OH)2 (4) and [Ni(Ipbh)2ClO4]ClO4 (5) have been synthesized. All the complexes were characterized by elemental analysis, molar conductivity, CHN analysis, spectroscopic studies, magnetic susceptibility measurements and TG/DTA methods. The solid-state structure of the complex 4 was established by single crystal X-ray crystallography. In all the complexes, Ipbh acts as a bidentate NO chelating age...

2011-01-01

91

Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?  

CERN Document Server

Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with ...

2008-01-01

92

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

93

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

94

Targeted drug delivery under MRI guidance  

British Library Electronic Table of Contents (United Kingdom)

The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...

2008-01-01

95

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...

2001-01-01

96

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

97

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed ...

98

Benzene molecule is destroyed by ultraviolet and soft X-rays in circumstellar environment  

International Nuclear Information System (INIS)

Benzene molecules , present in the proto-planetary nebula CRL 618, are ionized and dissociated by ultraviolet (UV) and X-ray photons originated from the hot central star and by its fast wind. Ionic species and free radicals produced by these processes can lead to the formation of new organic molecules. The aim of this work is to study the photoionization and photodissociation processes of the benzene molecule, using synchrotron radiation and time-of-flight mass spectrometry. Mass spectra were recorded at different energies corresponding to the vacuum UV (21.21 eV) and soft X-ray (282-310 eV) spectral regions. The production of ions from the benzene dissociative photoionization is here quantified, indicating that C_6H_6 is more efficiently fragmented by soft X-ray than UV radiation, where 50% of the ionized benzene molecules survive to UV dissociation while only about 4% resist to C-rays. Partial ion ...

99

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained ...

1994-10-01

100

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained ...

1994-01-01

101

Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays  

Energy Technology Data Exchange (ETDEWEB)

We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue of the quality of the ...

2005-10-11

102

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

Science.gov (United States)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...

2009-12-01

103

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

International Nuclear Information System (INIS)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...

2009-12-01

104

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

105

Large-area metallic photonic lattices for military applications.  

Energy Technology Data Exchange (ETDEWEB)

In this project we developed photonic crystal modeling capability and fabrication technology that is scaleable to large area. An intelligent optimization code was developed to find the optimal structure for the desired spectral response. In terms of fabrication, an exhaustive survey of fabrication techniques that would meet the large area requirement was reduced to Deep X-ray Lithography (DXRL) and nano-imprint. Using DXRL, we fabricated a gold logpile photonic crystal in the <100> plane. For the nano-imprint technique, we fabricated a cubic array of gold squares. These two examples also represent two classes of metallic photonic crystal topologies, the connected network and cermet arrangement.

2007-11-01

106

Free electron laser seeded by ir laser driven high-order harmonic generation  

International Nuclear Information System (INIS)

Coherent x-ray production by a seeded free electron laser (FEL) is important for next generation synchrotron light sources. The authors examine the feasibility and features of FEL emission seeded by a high-order harmonic generation (HHG) of an infrared laser. In addition to the intrinsic FEL chirp, the longitudinal profile and spectral bandwidth of the HHG seed are modified significantly by the FEL interaction well before saturation. This smears out the original attosecond pulselet structure. The authors introduce criteria for this smearing effect on the pulselet and the stretching effect on the entire pulse. They discuss the noise issue in such a seeded FEL.

2007-01-08

107

Evolution of the white dwarf mass and spin in cataclysmic variables  

International Nuclear Information System (INIS)

We consider the spin-up of the white dwarf in non-magnetic cataclysmic variables (CVs) during secular evolution. If this is unresisted, CVs are quenched as boundary-layer emitters once the binary period has decreased by #approx# 1 hr. Angular momentum loss in nova explosions may, however, prevent the star reaching breakup. If the explosions remove (1 + #epsilon#) x the mass accreted between outbursts, values 0.5 < #approx# #epsilon# < #approx# 1 allow CVs to be modest boundary-layer emitters for most of their lifetimes. Spectral effects will limit their detection as soft X-ray sources. (author).

108

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...

1992-07-01

109

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. ...

1996-01-01

110

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

International Nuclear Information System (INIS)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult ...

1987-01-01

111

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

112

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

113

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...

1992-01-01

114

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with ...

2009-01-01

115

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

116

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

117

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

118

X-ray Microdiffraction and Strain Gradient Crystal Plasticity Studies of Geometrically Necessary Dislocations Near a Ni Bicrystal Grain Boundary  

Energy Technology Data Exchange (ETDEWEB)

We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.

2009-01-01

119

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the ...

2009-01-01

120

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

121

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the ...

1986-01-01

122

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

123

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

124

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova ...

2011-05-01

125

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

126

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

127

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

128

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

129

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

134

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

135

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes ...

2011-05-05

136

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

137

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)

2009-11-01

138

Determination of the optimal speed of rotational display through an 180 degree arc in rotatostereoradiography and MR angiography  

International Nuclear Information System (INIS)

Rotatostereoradiographic (RSRG) images are displayed in an oscillating, rotational manner. While reviewing these rotating images, the radiologist may become psychologically irritated by the rotation. A rapidly rotating display of linear subjects gives one three-dimensional depth information. This three-dimensional sense is lost if the rotation speed is too slow. The authors of this paper determined the slowest possible rotating display speed that allows perception of three-dimensional depth information minimizing psychological irritation. In the RSRG device (Shimadzu ROTATO-360), an x-ray tube coupled with an image intensifier rotates through a 180 degrees arc in 1.8 or 2.25 seconds. Both rotation times could be doubled. The images were displayed at four different speeds, covering the 180 degrees arc in 1.8, 2.25, 3.6, and 4.5 seconds.

1990-11-25

139

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using ...

2009-09-01

140

3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture  

Energy Technology Data Exchange (ETDEWEB)

A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...

1993-11-01

141

The Hard X-ray Spectral Evolution in XRBs, AGNs and ULXs  

CERN Document Server

We explore the relationship between the hard X-ray photon index $\\Gamma$ and the Eddington ratio (\\xi=L_{X}(0.5-25 keV)/L_{Edd}) in six XRBs. We find that different XRBs follow different anti-correlations between $\\Gamma$ and $\\xi$ when $\\xi$ is less than a critical value, while they follow the same positive correlation when $\\xi$ is larger than the critical value. This anti-correlation and positive correlation are also found in LLAGNs and QSOs respectively, and the anti-correlation and positive correlation of different XRBs roughly converge to the same point ($\\log \\xi=-2.1, \\Gamma=1.5$), which may correspond to the accretion mode transition, since that the anti-correlation and positive correlation are consistent with the prediction of ADAFs and standard disk/corona system respectively. The traditional low/hard state are divided into two parts by the cross point $\\log \\xi\\sim-2.1$, i.e., faint-hard state in the anti-correlation part and bright-hard ...

2008-01-01

142

Luminescence properties of europium and terbium activated yttrium niobium/tantalate phosphors under VUV-UV excitation  

International Nuclear Information System (INIS)

Various compositions of Y(Ta,Nb)O4:Eu3+,Tb3+ with different Nb and activator concentrations have been investigated under UV and VUV excitation. Some compounds with very strong emission under VUV excitation were found. Such phosphors could be proposed as very good emissive materials for Displays and Lightings. The growing interest in luminescence spectroscopy of rare earth ions in the vacuum ultraviolet (VUV) and the visible (VIS) spectral range is due to industrial demands for new applications. YTaO4 and YNbO4 phosphors are a perspective class of efficient materials that are generally used in X-ray intensifying screens. These phosphors exhibit satisfying luminescence whenever excited by UV light, cathode radiation or X ray. However, to our knowledge, no work has been published on the VUV-excited luminescence for Eu3+ and Tb3+ double activated yttrium niobate and yttrium tantalate based phosphors. In ...

143

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency ...

2010-12-15

144

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

145

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired ...

2007-08-01

146

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

147

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

148

Spectral characteristics of lignite open cast mining systems: a preliminary status  

Energy Technology Data Exchange (ETDEWEB)

The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.

1999-07-01

149

Thermal infrared spectra of surface rocks. Comparison of in the laboratory, in situ, and remote sensing data; Chihyo ganseki no netsusekigaiiki bunko tokusei. Chijo sokutei data to remote sensing data no hikaku  

Energy Technology Data Exchange (ETDEWEB)

An ASTER (advanced spaceborne thermal emission and reflection radiometer) is one of the image sensors. It is to be installed in an earth survey polar orbit platform satellite, EOS-AM1, which is to be launched in 1998, and it is going to start its operation. Data observed by the thermal infrared remote sensing of ASTER include the spectral emissivity, and the spectral emission reflectivity which is expressed by the function of temperature. It is required to overcome technical problems how to extract the spectral emissivity from the observed data. The spectral emissivity extracted from the remote sensing data by the MMD method, measured for samples collected in Cuprite area, Nevada, and/or measured at sampled points were compared to each other and discussed. The hemisphere spectral reflectivity, which is indirect spectral emissivity, agreed ...

1996-10-01

150

Two dimensional power spectral density measurements of X-rayoptics with the Micromap interferometric microscope  

Energy Technology Data Exchange (ETDEWEB)

A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The ...

2005-05-12

151

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...

2008-06-01

152

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...

2002-01-01

153

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with ...

2001-06-01

154

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

155

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

156

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

157

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.

2004-02-28

158

Relativistic distorted-wave results for nickel-like gadolinium  

Science.gov (United States)

Electron collisional data are required for population kinetics modeling and spectral predictions of highly ionized ions in high-temperature plasmas. Nickel-like ions are especially interesting for their potential use in soft X-ray laser schemes pumped by electron collisional excitation and recombination. For highly stripped ions of moderate to high Z, relativistic effects begin to play a role in the atomic-physics calculations. A relativistic multiconfigurational distored-wave model has been used for the calculation of electron excitation cross sections and rate coefficients between the 3s2 3p6 3d10 Ni-like Gd ground state and the singly excited states with an N-shell electron.

1986-08-01

159

Optimization of a seeding option for the VUV free electron laser at DESY  

International Nuclear Information System (INIS)

In order to get fully coherent radiation from the Free Electron Laser (FEL) amplifier starting from the shot noise, it is foreseen to implement a seeding option into the VUV FEL being under construction at DESY (DESY print TESLA-FEL 95-03, Hamburg, DESY, 1995, Seeding option for the VUV free electron laser at DESY: joint DESY and GKSS proposal; Available at DESY upon request only). It consists of an additional undulator, a bypass for electrons and an X-ray monochromator. This paper presents the results of optimization of the seeding option for the VUV FEL providing maximal spectral brightness at minimal shot-to-shot intensity fluctuations. Calculations are performed with three-dimensional, time-dependent simulation code FAST (Nucl. Instr. and Meth. A 429 (1999) 233).

2000-05-01

160

A new method of determining the inclination angle in interacting binaries  

CERN Document Server

We describe a method of determining the system parameters in non-eclipsing interacting binaries. We find that the extent to which an observer sees the shape of the Roche-lobe of the secondary star governs the amount of distortion of the absorption line profiles. The width and degree of asymmetry of the phase-resolved absorption line profiles show a characteristic shape, which depends primarily on the binary inclination and gravity darkening exponent. We show that, in principle, by obtaining high spectral and time resolution spectra of quiescent cataclysmic variables or low mass X-ray binaries in which the mass-losing star is visible, fitting the shape of absorption line profiles will allow one to determine not only the mass function of the binary, but also the binary inclination and hence the mass of the binary components.

1998-01-01

161

Similarity between the primary and secondary air-assisted liquid jet breakup mechanism  

CERN Document Server

we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.

2007-01-01

162

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

163

Applications of Cerius2, software of molecular simulation; Aplicaciones de Cerius2, software de simulacion molecular  

Energy Technology Data Exchange (ETDEWEB)

Most of the investigations have a theoretical sustenance based on molecular simulation. The area of application of molecular simulation is very wide, in the Materials Technology Department assigned to the Applied Sciences Management have been treated problems about metallic nano structures, glasses, interfaces, and molecules, to sustain and to explain some of the experimental results. Energy calculations are carried out to determine minimum energy structures, for later on to carry out calculations of some of their properties; as well as the images simulation of Electron microscopy and X-ray diffraction. (Author)

2007-07-01

164

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

165

X-ray and vibrational spectroscopy of manganese complexes relevant to the oxygen-evolving complex of photosynthesis  

Energy Technology Data Exchange (ETDEWEB)

Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV for ...

2001-05-16

166

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

167

Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers  

International Nuclear Information System (INIS)

To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node ...

2003-02-01

168

The pre-outburst flare of the A 0535+26 August/September 2005 outburst  

CERN Document Server

We study the spectral and temporal behavior of the High Mass X-ray Binary A 0535+26 during a `pre-outburst flare' which took place ~5 d before the peak of a normal (type I) outburst in August/September 2005. We compare the studied behavior with that observed during the outburst. We analyse RXTE observations that monitored A 0535+26 during the outburst. We complete spectral and timing analyses of the data. We study the evolution of the pulse period, present energy-dependent pulse profiles both at the initial pre-outburst flare and close to outburst maximum, and measure how the cyclotron resonance-scattering feature (hereafter CRSF) evolves. We present three main results: a constant period P=103.3960(5)s is measured until periastron passage, followed by a spin-up with a decreasing period derivative of Pdot=(-1.69+/-0.04)x10^(-8)s/s at MJD 53618, and P remains constant again at the end of the main outburst. The spin-up ...

2008-01-01

169

High variability in Vela X-1: giant flares and off states  

CERN Document Server

We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates ...

2008-01-01

170

HD 100453: A Link Between Gas-Rich Protoplanetary Disks and Gas-Poor Debris Disks  

CERN Document Server

HD 100453 has an IR spectral energy distribution (SED) which can be fit with a power-law plus a blackbody. Previous analysis of the SED suggests that the system is a young Herbig Ae star with a gas-rich, flared disk. We reexamine the evolutionary state of the HD 100453 system by refining its age (based on a candidate low-mass companion) and by examining limits on the disk extent, mass accretion rate, and gas content of the disk environment. We confirm that HD 100453B is a common proper motion companion to HD 100453A, with a spectral type of M4.0V - M4.5V, and derive an age of 10 +/- 2 Myr. We find no evidence of mass accretion onto the star. Chandra ACIS-S imagery shows that the Herbig Ae star has L_X/L_Bol and an X-ray spectrum similar to non-accreting Beta Pic Moving Group early F stars. Moreover, the disk lacks the conspicuous Fe II emission and excess FUV continuum seen in spectra of actively accreting Herbig Ae stars, ...

2009-01-01

171

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details ...

2009-07-21

172

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise ...

2004-12-07

173

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating ...

2009-04-15

174

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

175

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

176

Estimating hip fracture risk from digital x-ray image data  

International Nuclear Information System (INIS)

The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.

177

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

178

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

179

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

180

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

181

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the ...

2010-07-23

182

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

183

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...

2009-03-22

184

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea ...

1986-01-01

185

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

186

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

187

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various ...

2008-04-01

188

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI ...

1997-04-01

189

Systems-level analysis of microbial community organization through combinatorial labeling and spectral imaging  

UK PubMed Central (United Kingdom)

Microbes in nature frequently function as members of complex multitaxon communities, but the structural organization of these communities at the micrometer level is poorly understood because of limitations...Full Text Available

2011-03-08

190

Colour television, an imitation of the human visual system.  

UK PubMed Central (United Kingdom)

Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available

1975-07-01

191

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

192

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

193

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1991-01-01

194

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1764-01-01

195

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...

1992-03-01

196

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

Energy Technology Data Exchange (ETDEWEB)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are ...

1987-04-01

197

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

199

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

200

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

201

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...

2001-09-23

202

Sequential changes in the femoral head after intracapsular fracture of the femoral neck. MRI findings  

International Nuclear Information System (INIS)

Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern ...

1998-07-01

203

General fundamentals of radiological diagnostics. Specific diagnostic radiology: Throat, mediastinum, diaphragm, mammary gland, infant thorax. 7. rev. ed.  

International Nuclear Information System (INIS)

The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view ...

204

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of ...

2006-03-01

205

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in ...

2006-01-01

206

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific ...

209

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

210

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

216

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

217

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

218

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

220

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

221

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

225

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...

2006-11-13

226

Upper Limits from HESS Observations of AGN in 2005-2007  

CERN Document Server

Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.

2007-01-01

227

The unusual host galaxy of the BL Lac object PKS 1413+135  

CERN Document Server

The BL Lacertae object PKS 1413+135 is associated with a disk dominated galaxy which heavily absorbs the BL Lac nucleus at optical and X-ray wavelengths. It has been argued whether this galaxy is actually the host galaxy of PKS 1413+135 or whether the BL Lac is a background QSO, gravitationally lensed by the apparent host galaxy. We have obtained deep high resolution H-band images of this unusual BL Lac object using the UKIRT IRCAM3. Our observations show that the BL Lac nucleus is centered within < 0.05 arcsec of the galaxy. Based on this result we assess the probability for the lensing scenario and come to the conclusion that the disk galaxy is indeed the host of PKS 1413+135. The galaxy shows peanut-shaped isophotes, suggesting the presence of a central bar which is a common feature of AGN

1999-01-01

228

The temporal evolution of coronal loops observed by GOES-SXI  

CERN Document Server

We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional ...

2006-01-01

229

Studies of technetium chemistry. Pt. 13: The relationship between solvation free energies and brain uptakes of "9"9Tc"m complexes  

International Nuclear Information System (INIS)

Based on the X-ray crystallographic data of Tc-complexes for brain imaging agents, geometry optimizations in vacuo of TcO-BAT, TcO-MAMA, TcO-L, L-ECD, TcN-BAT and TcN-L, L-ECD complexes are performed with Hartree-Fock method and LANL 2 DZ basis set of G98W program. Then solvation free energy for each Tc-complex mentioned above in water is calculated by polarizable continuum method (PCM) including models of CPCM and IEFPCM. The results show that solvation free energy of Tc-complex is not only an indicator of lipophilicity but also one of the important factors that influence the brain uptake

2002-02-01

230

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

231

In situ synthesis of silver chloride nanoparticles into bacterial cellulose membranes  

British Library Electronic Table of Contents (United Kingdom)

In situ synthesis of silver chloride (AgCl) nanoparticles was carried out under ambient conditions in nanoporous bacterial cellulose (BC) membranes as nanoreactors. The growth of the nanoparticles was readily obtained by alternating dipping of BC membranes in the solution of silver nitrate or sodium chloride followed by a rinse step. X-ray diffraction (XRD) patterns indicated the existence of AgCl nanoparticles in the BC and scanning electron microscopy (SEM) images showed that the AgCl nanoparticles well dispersed on the surface of BC and penetrated into the BC network. The AgCl nanoparticle-impregnated BC membranes exhibited high hydrophilic ability and strong antimicrobial activity against Escherichia coli (Gram-negative) and Staphylococcus aureus (Gram-positive). The preparative proced...

2009-01-01

232

High resolution electron microscopy study of as-prepared and annealed tungsten-carbon multilayers  

International Nuclear Information System (INIS)

A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.

233

Diffraction applications using the energy dispersive beamline X6A at the National Synchrotron Light Source  

Energy Technology Data Exchange (ETDEWEB)

The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.

1995-02-01

234

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

235

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

236

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...

2000-08-01

237

Development of Intelligent Setting System for Fracture Based on X-Ray Image  

Energy Technology Data Exchange (ETDEWEB)

In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power polymerization curved surface ...

2006-10-15

238

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

239

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

240

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

241

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other ...

2009-05-01

242

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average ...

2003-06-01

243

WITNESSING THE KEY EARLY PHASE OF QUASAR EVOLUTION: AN OBSCURED ACTIVE GALACTIC NUCLEUS PAIR IN THE INTERACTING GALAXY IRAS 20210+1121  

International Nuclear Information System (INIS)

We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the theoretical models of ...

2010-10-20

244

Si3C2-rings: from a nonconjugated trisilacyclopentadiene to an aromatic trisilacyclopentadienide and cyclic disilenide.  

Science.gov (United States)

1,2,3-Trisilacyclopenta-1,4-diene 2, featuring three skeletal Si atoms in the five-membered ring, was synthesized by the thermolysis of the 1,2,3-trisilabicyclo[1.1.0]butane derivative 1 at 130 degrees C in the presence of hex-3-yne. Possessing the properties of nonconjugated cyclopentadiene, 2 readily underwent reduction with KC(8), which was followed by treatment with LiBr to form the lithium salt of 1,2,3-trisilacyclopentadienide 3(-)*[Li(+)(thf)], from which the ketone-coordinated derivative 3(-)*[Li(+)(O=C(t)Bu(2))] was prepared. Both 3(-)*[Li(+)(L)] (L = thf, O=C(t)Bu(2)) are classified as novel 6pi-electron aromatic systems based on their characteristic X-ray crystal and NMR spectral data. Addition of 12-crown-4 to 3(-)*[Li(+)(thf)] resulted in the unexpected formation of 4(-)*[Li(+)(12-crown-4)(2)], featuring the unprecedented cyclic disilenide ion 4(-). PMID:19378994

2009-05-13

245

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...

2009-12-16

246

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 Hz)

2006-07-01

247

Chemistry of tervalent uranium. Preparation and properties of NH sub 4 UBr sub 4. 1. 5CH sub 3 CN. 6H sub 2 O  

Energy Technology Data Exchange (ETDEWEB)

The paper presents the preparation, X-ray powder diffraction data as well as some magnetic and spectroscopic properties of a new uranium(III) complex bromide of the formula NH{sub 4}UBr{sub 4}.1.5CH{sub 3}CN.6H{sub 2}O. The compound crystallizes in the monoclinic system with a=11.877 A, b=6.385 A, c=6.815 A, {beta}=101.29deg and Z=2. In the 60-240 K range it follows the Curie-Weiss law with {theta}=-37.24 K and {mu}{sub eff}=3.20 B.M. The IR and UV-VIS absorption spectra were recorded in the 80-4000 cm{sup -1} and 4000-26000 cm{sup -1} spectral ranges respectively. Thermal decomposition at a non-static high vacuum enabled the conversion of the compound into pure and anhydrous UBr{sub 3}. (orig.).

1990-07-01

248

Bulk-sensitive high-resolution photoemission study of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Eu 4f electronic structures of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2} have been investigated by bulk-sensitive high-resolution photoemission spectroscopy at temperatures from 20 to 300 K. The bulk Eu{sup 2+} 4f component is definitely distinguished from two surface Eu{sup 2+} 4f components. The changes in the spectral intensity of the bulk Eu{sup 2+} and Eu{sup 3+} 4f configurations and in the energy separation between these states are observed in the temperature dependent photoemission spectra. These temperature dependences are related to the valence transition of EuPd{sub 2}Si{sub 2}. The Eu mean valence is evaluated to be 2.75{+-}0.03 at 20 K and 2.30{+-}0.05 at 300 K. These values are in good agreement with those evaluated from Moessbauer and Eu L{sub III}-edge X-ray absorption measurements.

2004-07-01

249

A Chandra Observation of Supernova Remnant G350.1-0.3 and Its Central Compact Object  

CERN Document Server

We present a new Chandra observation of supernova remnant (SNR) G350.1-0.3. The high resolution X-ray data reveal previously unresolved filamentary structures and allow us to perform detailed spectroscopy in the diffuse regions of this SNR. Spectral analysis demonstrates that the region of brightest emission is dominated by hot, metal-rich ejecta while the ambient material along the perimeter of the ejecta region and throughout the remnant's western half is mostly low-temperature, shocked interstellar/circumstellar medium (ISM/CSM) with solar-type composition. The data reveal that the emission extends far to the west of the ejecta region and imply a lower limit of 6.6 pc on the diameter of the source (at a distance of 4.5 kpc). We show that G350.1-0.3 is likely in the free expansion (ejecta-dominated) stage and calculate an age of 600-1200 years. The derived relationship between the shock velocity and the electron/proton temperature ratio is ...

2011-01-01

250

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

251

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

252

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

253

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

254

Study of porous silicon morphologies for electron transport  

International Nuclear Information System (INIS)

Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous ...

1993-05-17

255

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; ...

1986-01-01

256

Probing the Large-Scale Structure Around the Most Distant Galaxy Clusters from the Massive Cluster Survey  

CERN Document Server

We present maps of the cosmic large-scale structure around the twelve most distant galaxy clusters from the Massive Cluster Survey (MACS) as traced by the projected surface density of galaxies on the cluster red sequence. Taken with the Suprime-Cam wide-field camera on the Subaru telescope, the images used in this study cover a 27x27 arcmin^2 area around each cluster, corresponding to 10 x 10 Mpc^2 at the median redshift of z = 0.55 of our sample. We directly detect satellite clusters and filaments extending over the full size of our imaging data in the majority of the clusters studied, supporting the picture of mass accretion via infall along filaments suggested by numerical simulations of the growth of clusters and the evolution of large-scale structure. A comparison of the galaxy distribution near the cluster cores with the X-ray surface brightness as observed with Chandra reveals, in several cases, significant offsets ...

2008-01-01

257

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were found to always originate at the pattern boundaries.

2001-04-01

258

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-12-01

259

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-01-01

260

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

261

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. ...

2007-05-07

262

Focused ion beam assisted three-dimensional rock imaging at submicron scale  

Energy Technology Data Exchange (ETDEWEB)

Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of ...

2003-05-09

263

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

264

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

265

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

266

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

267

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

268

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

269

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

270

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

271

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

272

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

273

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

274

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

275

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

276

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

277

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

278

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

279

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

280

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

281

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

282

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

283

Raman spectroscopic studies of carbon in extra-terrestrial materials  

International Nuclear Information System (INIS)

The measurements obtained here indicate ways in which micro-Raman spectroscopy can be used to elucidate structural characteristics and distribution of carbon in meteorites and interplanetary dust particles (IDPs). Existing information about structurally significant aspects of Raman measurements of graphite is combined with structurally relevant findings from the present micro-Raman studies of carbons prepared by carbonization of polyvinylidine chloride (PVDC) at various temperatures and natural material, as well as several acid residues from the Allende and Murchison meteorites in order to establish new spectra-structure relationships. Structural features of many of the materials in this study have been measured by x ray analysis and electron microscopy: thus, their structural differences can be directly correlated with differences in the Raman spectra. The spectral parameters consequently affirmed as indicators of ...

1990-04-01

284

Multidate image analysis of forest degradation in equatorial Africa  

Energy Technology Data Exchange (ETDEWEB)

A section of the northern margin of the Guineo-Congolian rain forest of the Central African Republic is studied to determine to what extent deforestation is evolving. Three sites are presented to highlight the diversity in local environmental settings at the northern margin of the closed equatorial rain forest: the contiguous equatorial rain forest, the boundary between the closed rain forest and the grasslands, and a predominantly secondary grassland environment. Proven image processing procedures for determining land cover and vegetation vigor were applied to Landsat MSS data to determine land cover characteristics and identify alterations in land cover that indicate potentially degraded forest environments. Land cover was independently assessed using spectral signatures determined from a statistical clustering routine. The images presented and image analyses contribute insights and information to an ...

1990-12-01

285

Land cover change of watersheds in Southern Guam from 1973 to 2001  

British Library Electronic Table of Contents (United Kingdom)

Land cover change can be caused by human-induced activities and natural forces. Land cover change in watershed level has been a main concern for a long time in the world since watersheds play an important role in our life and environment. This paper is focused on how to apply Landsat Multi-Spectral Scanner (MSS) satellite image of 1973 and Landsat Thematic Mapper (TM) satellite image of 2001 to determine the land cover changes of coastal watersheds from 1973 to 2001. GIS and remote sensing are integrated to derive land cover information from Landsat satellite images of 1973 and 2001. The land cover classification is based on supervised classification method in remote sensing software ERDAS IMAGINE. Historical GIS data is used to replace the areas covered by clouds or shadows in the image o...

2011-01-01

288

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

289

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

290
291

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

292

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

293

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

295

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

296

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

298

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

299

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

300

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe ...

2010-10-01

301

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

302

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

303

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

304

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

305

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

306

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

307

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

308

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

309

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

310

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

311

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

312

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to ...

2002-09-23

313

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

314

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

315

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

316

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

317

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

318

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

319

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

320

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

321

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

322

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

323

Structural and transport properties of illitized samples from drillhole OL-KR12 in Olkiluoto. Porosity, diffusion coefficient, permeability and tomographic imaging  

Energy Technology Data Exchange (ETDEWEB)

Six illitized samples from drillhole OL-KR12 in Olkiluoto were analyzed by helium gas methods for their diffusion coefficient, permeability and porosity. The diffusion coefficients measured varied in the range 2.1 x 10-10 - 3.5 x 10-8 m2/s, permeabilities in the range 6 x 10-21 - 5.8 x 10-16 m2, and porosities in the range 0.2 6.2%. Variations observed in these quantities were concluded to arise from the heterogeneous structure of the sample rock. A 4 mm x 4 mm x 4 mm subsample was sawed from each of the six samples for structural analysis by x-ray microtomography. The three-dimensional structure of tomographic reconstructions, and thereby that of the samples themselves, was analyzed visually, which confirmed their heterogeneity. Samples represent altered rock whose structure and thereby transport properties vary significantly depending on the local alteration history of the rock. (orig.)

2009-10-15

324

Optical and structural properties of Ge films from ion-assisted deposition  

International Nuclear Information System (INIS)

The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...

2008-11-28

325

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation between the FIB tail ...

1996-12-02

326

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...

2003-06-01

327

Electrochemical properties of Cu{sub 2}O/Cu composite particles prepared by a novel and facile method  

Energy Technology Data Exchange (ETDEWEB)

In this study, Cu{sub 2}O/Cu composite particles were synthesized using an innovative chemical reduction method without any template and surfactant. X-ray diffraction (XRD) analysis revealed that the product mainly consisted of Cu{sub 2}O phase coexisting with a Cu phase. FE-SEM images showed that the octahedral shaped particles were Cu{sub 2}O. The electrochemical performance of the Cu{sub 2}O/Cu particles was investigated with regards to the working electrode material in alkaline solution. The particles had a maximum discharge capacity of 222.9 mAh/g at a discharge current density of 60 mA/g and a high value of 109.1 mAh/g after 50 charge-discharge cycles. Cyclic voltammetry revealed that the reaction between Cu{sub 2}O and Cu is the major electrochemical reaction during the charging and discharging process. Electrochemical impedance spectroscopy revealed that the formation of Cu{sub 2}O on the surface of Cu particles increased the contact ...

2010-07-01

328

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

329

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

330

Comparative examinations of serum pepsinogen I, II and gastric area using computed radiography in the atrophic gastritis  

Energy Technology Data Exchange (ETDEWEB)

The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II ...

1995-11-01

331

Comparative examinations of serum pepsinogen I, II and gastric area using computed radiography in the atrophic gastritis  

International Nuclear Information System (INIS)

The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II ...

1995-01-01

332

An investigation of the capacitance dispersion on the fractal carbon electrode with edge and basal orientations  

Energy Technology Data Exchange (ETDEWEB)

Capacitance dispersion on the fractal carbon electrode with edge and basal orientations was investigated using atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and a.c.-impedance spectroscopy. For this purpose, four types of as-received pyrolytic graphite electrode, as-received, mechanically polished, and as-activated glassy carbon electrodes were prepared with different surface irregularities and amounts of edge orientations. The apparent self-similar fractal dimensions of the carbon electrodes were determined from the analyses of AFM images based upon triangulation method. The amounts of edge orientations on the surface of the carbon electrodes were qualitatively estimated from the XPS analysis of surface acidic functional groups that were preferably formed on the edge planes by the heat treatment of the carbon electrodes. The values of the constant phase element exponent {alpha} determined from the apparent self-similar ...

2003-10-15

333

A new fuel cell electrocatalyst based on carbonized polyacrylonitrile foam: The nature of platinum-support interactions  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) have been conducted on a new fuel cell electrocatalytic material based on a highly porous carbonized polyacrylonitrile (PAN) microcellular foam with very low platinum loading ({approximately}13 to 23 {micro}g/cm{sup 2}). TEM images of this material clearly show the existence of nanometer size platinum particles which are homogeneously distributed in the highly porous carbonized PAN matrix. An XPS study of Pt-loaded PAN indicates that C 1s, O 1s, and N 1s peaks shift to lower binding energies, compared to virgin PAN. It was concluded that special metal-support interaction exists, through the formation of a charge-transfer complex between platinum and pyridine-type nitrogen atoms of PAN support. This interaction leads to the enhancement of the catalytic activity, and the improvement of the long-time stability of this electrocatalyst.

1997-01-01

334

4U 1907+09: a HMXB running away from the Galactic plane  

CERN Document Server

We report the discovery of a bow shock around the high-mass X-ray binary (HMXB) 4U 1907+09 using the Spitzer Space Telescope 24 $\\mu$m data (after Vela X-1 the second example of bow shocks associated with HMXBs). The detection of the bow shock implies that 4U 1907+09 is moving through the space with a high (supersonic) peculiar velocity. To confirm the runaway nature of 4U 1907+09, we measured its proper motion, which for an adopted distance to the system of 4 kpc corresponds to a peculiar transverse velocity of $\\simeq 160 \\pm 115$ km/s, meaning that 4U 1907+09 is indeed a runaway system and supporting the general belief that most of HMXBs possess high space velocities. The direction of motion of 4U 1907+09 inferred from the proper motion measurement is consistent with the orientation of the symmetry axis of the bow shock, and shows that the HMXB is running away from the Galactic plane. We also present the Spitzer images of the bow shock ...

2011-01-01

335

The NIR Upgrade to the SALT Robert Stobie Spectrograph  

CERN Document Server

The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal ...

2006-01-01

336

Numerical Models of Sgr A*  

CERN Document Server

We review results from general relativistic axisymmetric magnetohydrodynamic simulations of accretion in Sgr A*. We use general relativistic radiative transfer methods and to produce a broad band (from millimeter to gamma-rays) spectrum. Using a ray tracing scheme we also model images of Sgr A* and compare the size of image to the VLBI observations at 230 GHz. We perform a parameter survey and study radiative properties of the flow models for various black hole spins, ion to electron temperature ratios, and inclinations. We scale our models to reconstruct the flux and the spectral slope around 230 GHz. The combination of Monte Carlo spectral energy distribution calculations and 230 GHz image modeling constrains the parameter space of the numerical models. Our models suggest rather high black hole spin ($a_*\\approx 0.9$), electron temperatures close to the ion temperature ($T_i/T_e ...

2010-01-01

337

Coefficient of Variation Spectral Analysis: An Application to ...  

Science.gov (United States)

... A major problem in the analysis of power spectral density measurements is distinguishing between narrowband spectral components of interest ...

1983-05-03

338

Extracting mining subsidence land from remote sensing images based on domain knowledge  

Energy Technology Data Exchange (ETDEWEB)

Extracting mining subsidence land from remote sensing (RS) images is one of important research contents for environment monitoring in mining area. The accuracy of traditional extracting models based on spectral features is low. In order to extract subsidence land from RS images with high accuracy, some domain knowledge should be imported and new models should be proposed. This paper, in terms of the disadvantage of traditional extracting models, imports domain knowledge from practice and experience, converts semantic knowledge into digital information, and proposes a new model for the specific task. By selecting the Luan mining area as a study area, this new model is tested based on GIS and related knowledge. The result shows that the proposed method is more precise than traditional methods and can satisfy the demands of land subsidence monitoring in mining area. 10 refs., 4 figs., 1 tab.

2008-06-15

339

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. ...

2000-07-01

340

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...

2000-01-01

341

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...

2003-11-01

342

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" ...

2007-01-01

343

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength ...

2009-11-15

344

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture ...

1991-12-01

345

Demonstration of realtime radiography on pipeline girth welds: Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...

1988-09-01

346

Synthesis and spectral characteristics of Sr2Y8(SiO4)6O2: Eu polycrystals  

International Nuclear Information System (INIS)

Spectral-luminescent characteristics of Sr2Y8(SiO4)6O2: Eu powder crystal phosphor with the apatite structure and high-intensity luminescence of Eu3+ ions have been studied. The charge state of europium in the samples has been characterized by means of X-ray L3-adsorption spectroscopy. It was established that Eu3+ forms two types of optical centers. Besides, luminescence of Eu2+ions was found. Reduction Eu3+#->#Eu2+ was considered, which may be due to VSr|| vacancy formation in the 4f crystal lattice position and to negative charge transfer by this vacancy to two EuY3+ ions. Thus, in the silicate lattice there exist inhomogeneously distributed oxygen-deficient centers, which are responsible for nonradiative transfer of excitation energy to Eu3+ and Eu2+ ions. To study electron-vibrational interactions in the crystal phosphor samples, their IR and Raman spectra were examined. In the luminescence spectrum of Eu2+, a series of low-intensity ...

2011-01-01

347

Spectral analysis of Pr3+-, Sm3+- and Dy3+-doped transparent GeO2-BaO-TiO2 glass ceramics  

British Library Electronic Table of Contents (United Kingdom)

In this paper, we present the photoluminescence properties of Pr3+-, Sm3+- and Dy3+-doped germanate glasses and glass ceramics. From the X-ray diffraction measurement, the host glass structure was determined. These glasses have shown strong absorption bands in the near-infrared (NIR) region. Compared to Pr3+-, Sm3+- and Dy3+-doped glasses, their respective glass ceramics have shown stronger emissions due to the Ba2TiGe2O8 crystalline phase. For Pr3+-doped glass and glass ceramic, emission bands centered at 530nm (3P03H5), 614nm (3P03H6), 647nm (3P03F2) and 686nm (3P03F3) have been observed with 485nm (3H43P0) excitation wavelength. Of them, 647nm (3P03F2) has shown bright red emission. Emission bands of 4G5/26H5/2 (565nm), 4G5/26H7/2 (602nm) and 4G5/26H9/2 (648nm) for the Sm3+:glass and gl...

2009-01-01

348

Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984  

Energy Technology Data Exchange (ETDEWEB)

The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following estimates can be derived by ...

1985-03-01

349

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area source when ...

2003-03-04

350

Influence of phosphorus vapor ambient for InGaAsP growth on GaAs substrate  

Science.gov (United States)

For visible-light-emitting laser diodes, InGaAsP double heterostructures have been grown on GaAs substrates using liquid-phase epitaxy. As the growth temperature is as high as about 780 /sup 0/C, a large amount of phosphorus evaporates from the solutions for the cladding layers during the growth process. The phosphorus vapor disturbs the solution composition for the active layer, so that very thin and uniform active layers cannot be obtained. By using In-P-Sn solution and supplying the phosphorus partial pressure around the graphite boat, the influence of phosphorus vapor ambient for InGaAsP (lambda/sub P//sub L/ = 805 nm) growth is confirmed. When the phosphorus partial pressure increases, the surface of epitaxial layer becomes rough and the substrate is partly etched back. From x-ray diffraction and photoluminescence spectral measurements, the composition of the grown layer is also found to be changed. As a result of increasing the flow rate ...

1986-12-01

351

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region observations. I have approached ...

2005-01-15

352

Central engine of quasars and AGNs: a relativistic proton radiative shock  

International Nuclear Information System (INIS)

Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas (1984), if ...

1985-08-01

353

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

354

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

355

Standard samples for X-ray radiometric analysis of substance composition  

International Nuclear Information System (INIS)

Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.

356

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

357

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

358

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

359

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

360

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

361

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

362

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

363

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

364

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

365

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

366

Applications of X-ray scattering in pharmaceutical science  

British Library Electronic Table of Contents (United Kingdom)

The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.

2011-01-01

367

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

368

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

369

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

370

Experimental generation of non-Kolmogorov turbulence using a liquid crystal spatial light modulator  

Science.gov (United States)

Several experiments showed that the classical Kolmogorov power spectral density of the refractive-index sometimes does not properly describe the statistics of the atmosphere. In this paper we show an experimental testbed able to generate non-classical Kolmogorov turbulence by using a liquid crystal spatial light modulator. The testbed is used at Naval Postgraduate School for laboratory investigation of laser beam propagation in maritime environment where a power law different from classical Kolmogorov, 11/ 3, could be present. Applications of this testbed are ship to-ship free space optical communication, imaging and high energy laser weapons.

2011-09-01

371

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

372

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

373

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

375

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

376

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

377

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

379

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

380

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

381

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

382

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

385

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

386

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

387

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

388

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

389

On the Z-dependence of K#alpha#_1/K#beta#_1 X-ray intensity ratio  

International Nuclear Information System (INIS)

1976. Germany Ramaswamy, MK Birla Inst. of Tech. and Science, Pilani

1976-03-29

390

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

391

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

392

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

393

Koji Mukai's Bibliography - Astrophysics Science Division Staff ...  

Science.gov (United States)

Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...

394

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

395

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

396

Future instrumentation for the study of the Warm-Hot Intergalactic Medium  

CERN Document Server

We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.

2008-01-01

397

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

398

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

399

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

400

Density Gradients for Isolation of Mononuclear Blood Cells for ...  

Science.gov (United States)

... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...

2011-05-15

403

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

404

Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues  

Science.gov (United States)

Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied ...

2011-02-01

405

Spitzer Imaging of Herschel-ATLAS Gravitationally Lensed Submillimeter Sources  

CERN Document Server

We present physical properties of two submillimeter selected gravitationally lensed sources, identified in the Herschel Astrophysical Terahertz Large Area Survey. These submillimeter galaxies (SMGs) have flux densities > 100 mJy at 500 um, but are not visible in existing optical imaging. We fit light profiles to each component of the lensing systems in Spitzer IRAC 3.6 and 4.5 um data and successfully disentangle the foreground lens from the background source in each case, providing important constraints on the spectral energy distributions (SEDs) of the background SMG at rest-frame optical-near-infrared wavelengths. The SED fits show that these two SMGs have high dust obscuration with Av ~4 to 5 and star formation rates of ~100 M_sun/yr. They have low gas fractions and low dynamical masses compared to 850 um selected galaxies.

2010-01-01

406

Investigation of the unsteadiness of a shock-reflection interaction with time-resolved particle image velocimetry  

British Library Electronic Table of Contents (United Kingdom)

The spatio-temporal dynamics of an impinging shock/boundary layer interaction at Mach 2 and under incipient separation conditions, has been investigated experimentally by means of high-speed particle image velocimetry (PIV). The available PIV acquisition rate of up to 20 kHz permits a time-resolved characterization of the interaction. The dynamics of different flow regions?notably the separation region and the reflected shock?were quantified by means of temporal auto-correlation fields and pseudo-spectral analysis. The PIV data further enable to investigate the relationship between spatially extended flow features, such as shock position and bubble size, as well as the influence of the upstream boundary layer. The results confirm earlier studies that there is an important upstream effect o...

2011-01-01

407

Analysis of the changes of vegetation coverage of western Beijing mountainous areas using remote sensing and GIS  

British Library Electronic Table of Contents (United Kingdom)

Mentougou District acts as a crucial component in the ecological buffer in western Beijing mountainous areas, Beijing, China. Using two Landsat MSS/TM images acquired on July 14, 1979 and July 23, 2005, the vegetation coverage of Mentougou District was calculated based on normalized difference vegetation index and spectral mixture analysis (NDVI-SMA) model. Its temporal and spatial changes were analyzed according to digital elevation model (DEM) image, social and economic data. The results showed that the vegetation coverage decreased from 76.4% in 1979 to 72.7% in 2005. Vegetation degradation was probably the result of human disturbance, such as outspreading of resident areas, and coal and stone mining activities, while vegetation restoration might be contributed by the combined effects o...

2009-01-01

408

First Light for MIRSI  

Science.gov (United States)

We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system ...

2001-12-01

409

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis ...

2000-08-01

410

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

411

Structural Analysis for Gold Mineralization Using Remote Sensing and Geochemical Techniques in a GIS Environment: Island of Lesvos, Hellas  

International Nuclear Information System (INIS)

Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from the lineament maps and the collected field ...

2000-12-01

412

Development of homogeneous mixing technology of dispersion nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

The measurement methods of homogeneity of dispersion fuel were analyzed. The effects of mixing method, rotating speed, particle shape, particle size and moisture content on homogeneity of U{sub 3}Si/Al powder mixture were characterized by the apparent density measurement. The effects of fuel particle shape on green properties and optimum compaction conditions were investigated in U{sub 3}Si{sub 2}/Al powder compacts. 3 kinds of measurement method on the homogeneity were analyzed by apparent density measurement method, x-ray image contrast method and image analysis method of mixed powders or fuel rods. The homogeneity of dispersed fuel powder mixture was analyzed using three kinds of mixing, by apparent density measurements method. The homogeneity of powder mixture increased with rotating speed of the V-shape tumbler mixer. The comminuted irregular shaped particles and smaller particle size of fuel powders showed homogeneity ...

2000-04-01

413

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

414

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

415

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

416

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

417

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

418

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

419

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

420

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

421

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

422

Structural intermediates in the assembly of taxoid-induced microtubules and GDP-tubulin double rings: time-resolved X-ray scattering.  

UK PubMed Central (United Kingdom)

We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available

1996-05-01

423

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

424

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

425

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

426

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

427

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

428

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell ...

429

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

430

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

431

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

432

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

433

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

434

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

435

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

436

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

437

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

438

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

439

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

440

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

441

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

442

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

443

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

444

Comments on possible preferential order-disorder in A-15 compounds based upon Nb  

International Nuclear Information System (INIS)

The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).

445

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

446

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

447

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

448

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

449

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

450

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

451

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

452

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

453

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

454

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

455

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

456

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days ...

2001-01-01

457

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and ...

2009-08-11

458

X-ray and HeI 1.0830 mu emission from protostellar jets  

CERN Document Server

Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical models of intermediately fast (> 500 - ...

2006-01-01

459

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power law model with ...

2010-01-01

460

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

461

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

462

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with ...

2011-01-01

463

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

464

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, ...

2007-01-01

465

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

Energy Technology Data Exchange (ETDEWEB)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray intensity ratio was found to ...

1983-09-01

466

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

International Nuclear Information System (INIS)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ratio was found to be an ...

1982-10-01

467

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

468

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of ...

2008-01-01

469

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide ...

1987-05-13

470

Vibration signature analysis of AFM images  

Energy Technology Data Exchange (ETDEWEB)

Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging method were investigated for application ...

1995-12-31

471

Remote sensing monitoring method of hyperspectral and high-resolution for underground coal bed combustion  

Energy Technology Data Exchange (ETDEWEB)

Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface ...

2007-10-15

472

Nonlinear Bayesian Algorithms for Gas Plume Detection and Estimation from Hyper-spectral Thermal Image Data  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a nonlinear Bayesian regression algorithm for the purpose of detecting and estimating gas plume content from hyper-spectral data. Remote sensing data, by its very nature, is collected under less controlled conditions than laboratory data. As a result, the physics-based model that is used to describe the relationship between the observed remotesensing spectra, and the terrestrial (or atmospheric) parameters that we desire to estimate, is typically littered with many unknown "nuisance" parameters (parameters that we are not interested in estimating, but also appear in the model). Bayesian methods are well-suited for this context as they automatically incorporate the uncertainties associated with all nuisance parameters into the error estimates of the parameters of interest. The nonlinear Bayesian regression methodology is illustrated on realistic simulated data from a three-layer model for longwave infrared (LWIR) measurements from a passive ...

2007-06-13

473

Broadband Imaging Segregation of z ~ 3 Ly-alpha Emitting and Ly-alpha Absorbing Galaxies  

CERN Document Server

The spectral properties of Lyman break galaxies (LBGs) offer a means to isolate pure samples displaying either dominant Ly-alpha in absorption or Ly-alpha in emission using broadband information alone. We present criteria developed using a large z ~ 3 LBG spectroscopic sample from the literature that enables large numbers of each spectral type to be gathered in photometric data, providing good statistics for multiple applications. In addition, we find that the truncated faint, blue-end tail of z ~ 3 LBG population overlaps and leads directly into an expected Ly-alpha emitter (LAE) population. As a result, we present simple criteria to cleanly select large numbers of z ~ 3 LAEs in deep broadband surveys. We present the spectroscopic results of 32 r' <~ 25.5 LBGs and r' <~ 27.0 LAEs at z ~ 3 pre-selected in the Canada-France-Hawaii Telescope Legacy Survey that confirm these criteria.

2009-01-01

474

THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 #<=# z #<=# 1.2  

International Nuclear Information System (INIS)

We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical emission line diagnostics are considered for ...

2010-08-01

475

THE DOUBLE-DEGENERATE NUCLEUS OF THE PLANETARY NEBULA TS 01: A CLOSE BINARY EVOLUTION SHOWCASE  

International Nuclear Information System (INIS)

We present a detailed investigation of SBS 1150+599A, a close binary star hosted by the planetary nebula PN G135.9+55.9 (TS 01). The nebula, located in the Galactic halo, is the most oxygen-poor known to date and is the only one known to harbor a double degenerate core. We present XMM-Newton observations of this object, which allowed the detection of the previously invisible component of the binary core, whose existence was inferred so far only from radial velocity (RV) and photometric variations. The parameters of the binary system were deduced from a wealth of information via three independent routes using the spectral energy distribution (from the infrared to X-rays), the light and RV curves, and a detailed model atmosphere fitting of the stellar absorption features of the optical/UV component. We find that the cool component must have a mass of 0.54 #+-# 0.2 M_s_u_n, an average effective temperature, T_e_f_f, of 58,000 #+-# 3000 K, a mean ...

2010-05-01

476

Aerosol spectral optical depths - Jet fuel and forest fire smokes  

Science.gov (United States)

The Ames autotracking airborne sun photometer was used to investigate the spectral depth between 380

1990-01-01

477

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...

1981-01-01

478

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

479

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values ...

1987-01-01

480

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the ...

1987-01-01

481

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

482

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input ...

483

Synthesis characterization and biological evaluation of a novel mixed ligand "9"9"mTc complex as potential brain imaging agent  

International Nuclear Information System (INIS)

One approach in the design of neutral oxotechnetium complexes is based on the simultaneous substitution of a tridentate dianionic ligand and a monodentate monoanionic coligand on a [Tc(V)O]"+"3 precursor. Following this ''mixed ligand'' concept, a novel "9"9"mTc complex with N,N-bis(2-mercaptoethyl)-N'N'-diethylethylenediamine as ligand and 1-octanethiol as coligand is prepared and evaluated as potential brain radiopharmaceutical. Preparation of the complex at tracer level was accomplished by using "9"9"mTc-glucoheptonate as precursor. The substitution was optimized and a coligand/ligand ratio of 5 was selected. Under this conditions the labeling yield was over 80% and a major product (with radiochemical purity > 80%) was isolated by HPLC methods and used for biological evaluation. Chemical characterization at carrier level was developed using the corresponding rhenium complex as structural model. The Re complex was also prepared by substitution method and isolated as a crystalline ...

1998-08-01

484

Lung studies with spiral CT. pitch 1 versus pitch 2; Confronto tra diversi parametri (pitch 1 e 2) nello studio del polmone con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality. [Italian] Nella Tomografia Computerizzata (TC) spirale il rapporto tra la distanza percorsa dal lettino portapaziente in una rotazione e lo spessore nominale dello strato, entrambi espressi in millimetri, si definische pitch. Se i due valori del rapporto coincidono si avra' pitch uguale a 1, mentre raddoppiando la distanza percorsa dal lettino portapaziente, per il medesimo spessore nominale, conseguentemente raddoppia il pitch (pitch 2). Eseguire gli esami TC spirale utilizzando pitch 2, consente di ridurre la durata dell'esame, la dose ...

1999-03-01

485

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. tensile experiment. ...

486

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, ...

2005-11-04

487

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den Okzipitalkondylen, die ...

1995-01-01

488

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

489

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

490

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

491

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

492

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

493

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

494

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

495

Exploring the Physics of Type Ia Supernovae Through the X-ray Spectra of their Remnants  

CERN Document Server

We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-ray emission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.

2005-01-01

496

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

497

An X-ray photoelectron spectroscopic study of B-N-Ti system  

International Nuclear Information System (INIS)

Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.

1997-04-04