An Apparent Hard X-ray Decline of CH Cygni
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
2006-01-01
We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line ...
2008-01-01
A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared ...
2005-01-01
Hard X-ray identification of Eta Carinae and steadiness close to periastron
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous ...
2010-01-01
Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the ...
2003-01-01
X-ray dosimetry of TlGaSe_2 single crystals
International Nuclear Information System (INIS)
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal ...
The intriguing nature of the high energy gamma ray source XSSJ12270-4859
The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence ...
2010-01-01
Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)
Energy Technology Data Exchange (ETDEWEB)
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...
1989-11-01
Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...
1989-11-01
X-ray and HeI 1.0830 mu emission from protostellar jets
Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence ...
2006-01-01
An X-ray source population study of the Andromeda galaxy M 31
XMM-Newton EPIC observations reveal the population of X-ray sources of the bright Local Group spiral galaxy M 31, a low-star-formation-rate galaxy like the Milky Way, down to a 0.2-4.5 keV luminosity of 4.4E34 erg/s. With the help of X-ray hardness ratios and optical and radio information different source classes can be distinguished. The survey detected 856 sources in an area of 1.24 square degrees. Sources within M 31 are 44 supernova remnants (SNR) and candidates, 18 super-soft sources (SSS), 16 X-ray binaries (XRBs) and candidates, as well as 37 globular cluster sources (GlC) and candidates, i.e. most likely low mass XRBs within the GlC. 567 hard sources may either be XRBs or Crab-like SNRs in M 31 or background AGN. 22 sources are ...
2005-01-01
Phase imaging using laser-produced X-ray sources
International Nuclear Information System (INIS)
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
2000-08-01
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the ...
2010-01-01
Generation of microwaves and hard X-rays in a flash X-ray tube
Energy Technology Data Exchange (ETDEWEB)
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to ...
1987-01-01
International Nuclear Information System (INIS)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated ...
1987-01-01
Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other ...
2010-01-28
International Nuclear Information System (INIS)
K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...
2010-06-01
Energy Technology Data Exchange (ETDEWEB)
A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular ...
2009-09-01
Study of the cyclotron feature in MXB 0656-072
We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.
2006-01-01
A pump-probe XFEL particle injector for hydrated samples
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.
2011-01-01
Simulating Large-scale Structure
After two decades of direct dynamical simulation of large-scale structure in the universe, it is safe to say the subject is now mature. Still, there are parts of the problem that are less well developed than others. In general, the collisionless dynamics of the dark matter component is better understood than the collisional gas dynamics of the baryonic component. In situations where the gas dynamics is relatively simple, such as the Lyman-$\\alpha$ forest and the intracluster medium in X-ray clusters, our ability to reproduce observational data has evolved rapidly, and the interpretive and predictive power of such experiments should now be taken seriously. A comparison of twelve gas dynamic codes to the problem of forming a single X-ray cluster shows that numerical inaccuracies are modest (typically below ten percent), leaving missing physics as the main source for large systematic differences between ...
1998-01-01
Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft
Energy Technology Data Exchange (ETDEWEB)
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding ...
1992-01-01
International Nuclear Information System (INIS)
The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as ...
2001-09-23
Future of X-ray phase imaging in medical imaging technology
International Nuclear Information System (INIS)
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
1993-09-01
Integration and Testing of the Micro-X Rocket Payload
The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will ...
2011-05-01
Neutron star evolution and emission
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.
1981-01-01
Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources
Energy Technology Data Exchange (ETDEWEB)
A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)
2000-07-01
Grating-based X-ray phase imaging using multiline X-ray source
International Nuclear Information System (INIS)
Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
2000-01-01
Polycrystalline powders of Na{sub 2x}Mn{sub 1-x}PS{sub 3} have been synthesized from layered MnPS{sub 3} material by successive ion-exchange intercalation of potassium and sodium ions. Their x-ray photoelectron spectroscopy (XPS) and x-ray excited Auger spectroscopy spectra have been measured at room temperature using Mg K{alpha} (1253.6 eV) x-ray source. In particular, the Mn, P, and S 2p and Na 1s and 2p core-level regions and the Na Auger KL{sub 23}L{sub 23} transition have been investigated. All the analyzed XPS core-level spectra display a single-peak structure, suggesting the absence of nonequivalent atoms of Na, Mn, P, and S. The manganese XPS spectrum shows, as observed in MnPS{sub 3} and in its cesium and potassium intercalation compounds, typical shake-up satellites, suggesting that the Mn-S bond is yet mainly ionic in nature. The comparison with the XPS spectra relative ...
2008-12-15
International Nuclear Information System (INIS)
At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
1999-06-01
International Nuclear Information System (INIS)
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to ...
2002-03-01
Radionuclide X-ray fluorescence analysis of components of the environment
International Nuclear Information System (INIS)
The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).
1983-01-01
Quantitative phase imaging using hard x-rays
International Nuclear Information System (INIS)
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
2009-02-01
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues
International Nuclear Information System (INIS)
Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).
1986-11-01
Hard X-ray phase imaging and tomography using a grating interferometer
International Nuclear Information System (INIS)
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
2007-07-01
Multielement analysis of air samples
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).
1981-01-01
X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt
Energy Technology Data Exchange (ETDEWEB)
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
1985-03-01
Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report
Energy Technology Data Exchange (ETDEWEB)
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
1992-03-01
Soft x-ray microradiography and lithograph using a laser produced plasma source
Energy Technology Data Exchange (ETDEWEB)
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
1992-01-01
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Theoretical considerations for X-ray phase contrast mammography by Thomson source
Energy Technology Data Exchange (ETDEWEB)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much ...
2009-09-01
X-ray production with sub-picosecond laser pulses
Energy Technology Data Exchange (ETDEWEB)
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to ...
1993-12-31
Portable fluid X-ray diagnostic system
Energy Technology Data Exchange (ETDEWEB)
A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source ...
1989-02-14
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons ...
2007-01-01
Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator
Energy Technology Data Exchange (ETDEWEB)
A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical ...
2009-02-11
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one ...
2010-06-15
CuBr blue light emitting electroluminescent thin film devices
British Library Electronic Table of Contents (United Kingdom)
Abstract Visible blue cathodoluminescence (CL), photoluminescence (PL), x-ray excited optical luminescence (XEOL) and electroluminescence (EL) via Zf free excitonic emission have been obtained from CuBr thin films deposited on glass, Cr coated glass, GaAs and Si substrates. In addition to the Zf emission several peaks corresponding to Cu+ emissions via 3d94s - d10 transitions were observed on the AC EL spectrum at 2.10, 2.7, 3.03, 3.07 and 3.80 eV. X-ray diffraction (XRD) measurements confirmed that the vacuum evaporated CuBr thin films grow preferentially with a (111) orientation irrespective of the substrate. While the AC voltage source was found to have no detrimental effects on CuBr thin films, cathodic deposition of Cu metal via electrolytic decomposition was observed under steady sta...
2011-01-01
Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
Energy Technology Data Exchange (ETDEWEB)
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
1985-01-15
Energy Technology Data Exchange (ETDEWEB)
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by ...
1988-01-01
Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium
International Nuclear Information System (INIS)
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the ...
2003-11-01
Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb
Energy Technology Data Exchange (ETDEWEB)
Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus
1993-03-01
Koji Mukai's Bibliography - Astrophysics Science Division Staff ...
Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...
The Use of Weighting in Periodicity Searches in All-Sky Monitor Data: Applications to the GLAST LAT
Energy Technology Data Exchange (ETDEWEB)
The light curves produced by all-sky monitors, such as the Rossi X-ray Timing Explorer All-Sky Monitor and the Swift Burst Alert Telescope (BAT), generally have non-uniform error bars. In searching for periodic modulation in this type of data using power spectra it can be important to use appropriate weighting of data points to achieve the best sensitivity. It was recently demonstrated that for Swift BAT data a simple weighting scheme can actually sometimes reduce the sensitivity of the power spectrum depending on source brightness. Instead, a modified weighting scheme, based on the Cochran semi-weighted mean, gives improved results independent of source brightness. We investigate the benefits of weighting power spectra in period searches using simulated GLAST LAT observations of {gamma}-ray binaries.
2009-06-25
The investigations on K and L X-ray fluorescence parameters of gold compounds
British Library Electronic Table of Contents (United Kingdom)
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
2010-01-01
DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1
International Nuclear Information System (INIS)
We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of ...
2010-12-10
Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide
Energy Technology Data Exchange (ETDEWEB)
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...
2010-11-24
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.
1999-06-01
International Nuclear Information System (INIS)
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.
1999-06-01
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
1999-06-15
A Virtual Young's Double Slit Experiment for Hard X-ray Photons
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
2009-01-01
Applications of X-ray scattering in pharmaceutical science
British Library Electronic Table of Contents (United Kingdom)
The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.
2011-01-01
The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.
2011-08-01
A numerical simulation of the evolution and fate of a FRI jet. The case of 3C 31
The evolution of FRI jets has been long studied in the framework of the FRI-FRII dichotomy. In this paper, we test the present theoretical and observational models via a relativistic numerical simulation of the jets in the radio galaxy 3C 31. We use the parameters derived from the modelling presented by \\cite{lb02a,lb02b} as input parameters for the simulation of the evolution of the source, thus assuming that they have not varied over the lifetime of the source. We simulate about 10 % of the total lifetime of the jets in 3C 31. Realistic density and pressure gradients for the atmosphere are used. The simulation includes an equation of state for a two-component relativistic gas that allows a separate treatment of leptonic and baryonic matter. We compare our results with the modelling of the observational data of the source. Our results show that the bow shock evolves self-similarly ...
2007-01-01
Pulse source of electron and X-ray radiations of subnanosecond duration
International Nuclear Information System (INIS)
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
Magnetospheric particle acceleration and X-ray emission of pulsars
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2007-01-01
K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22
International Nuclear Information System (INIS)
The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.
1994-01-01
Acceleration of particles in pulsar magnetosphere and the X-ray radiation
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2004-01-01
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
International Nuclear Information System (INIS)
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)
Energy Technology Data Exchange (ETDEWEB)
As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.
2002-06-18
A radionuclide analyzer of total sulfur in coal
International Nuclear Information System (INIS)
The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total ...
1987-05-13
Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters
International Nuclear Information System (INIS)
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
1992-01-01
FLASH-the first soft x-ray free electron laser (FEL) user facility
Energy Technology Data Exchange (ETDEWEB)
The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.
2010-10-14
Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)
1999-06-01
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.
1993-12-01
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.
1993-01-01
Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry
Energy Technology Data Exchange (ETDEWEB)
An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.
1996-11-01
Translocation of labelled sucrose: A student exercise
Energy Technology Data Exchange (ETDEWEB)
Photosynthetic carbohydrates from the leaves are exported through the phloem to growing tips, roots, flowers and fruits. If sucrose labelled with {sup 14}C is applied to the leaves of bean plants, the pathway for sugar movement may be readily observed by autoradiography. Students apply the labelled sucrose during class time and return the next day to press their plants. During the next class, the pressed and dried plants are placed against X-ray film and left in the dark for four weeks. the film is then developed, examined for presence of label and compared to the pressed plants. Source to sink movement is clearly illustrated and information about the mechanism of phloem transport and loading is gained through experimental treatments, which include blocking the phloem pathway and inhibiting energy production.
1990-05-01
International Nuclear Information System (INIS)
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
2004-10-15
Ion-induced M X-ray emission from heavy lanthanides
International Nuclear Information System (INIS)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).
1987-12-01
We construct a sample of low-redshift Ly-alpha emission-line selected sources from GALEX grism spectroscopy of nine deep fields to study the role of Ly-alpha emission in galaxy populations with cosmic time. Our final sample consists of 122 (142) sources selected in the redshift interval z=0.195-0.44 (z=0.65-1.25) from the FUV (NUV) channel. We classify the Ly-alpha sources as AGNs if high-ionization emission lines are present in their UV spectra and as galaxies otherwise. These classifications are broadly supported by comparisons with X-ray and optical spectroscopic observations. We classify additional sources as AGNs using line widths for our Ly-alpha emitter (LAE) analysis. Defining the GALEX LAE sample in the same way as high-redshift LAE samples, we show that LAEs constitute only about 5% of NUV-continuum selected galaxies at z~0.3. We also show that they ...
2009-01-01
Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance
Energy Technology Data Exchange (ETDEWEB)
We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by ...
2010-06-02
X rays in molecular biophysics
Energy Technology Data Exchange (ETDEWEB)
An atom-by-atom understanding of life processes is emerging from a flurry of experiments fueled by synchrotron sources and DNA technology. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}.
1995-11-01
Using X-ray Microscopy and Hg L3 XANES to study Hg Binding in the Rhizosphere of Spartina Cordgrass
UK PubMed Central (United Kingdom)
San Francisco Bay has been contaminated historically by mercury from mine tailings as well as contemporary industrial sources. Native Spartina foliosa and non-native S....Full Text Available
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.
2003-09-10
Design considerations for the magnetic system of a prototype x-ray free electron laser
Energy Technology Data Exchange (ETDEWEB)
A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.
1997-04-01
High variability in Vela X-1: giant flares and off states
We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement ...
2008-01-01
X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray ...
2001-01-01
X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals
International Nuclear Information System (INIS)
Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics ...
2003-09-15
Spherically bent crystal spectroscopy in laser-produced plasma
International Nuclear Information System (INIS)
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. ...
2008-02-01
We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, ...
2011-01-01
X-ray observation of a. sqrt. 3 x. sqrt. 3 superlattice in KC/sub 8/ at high pressure
Energy Technology Data Exchange (ETDEWEB)
A single-crystal x-ray study under pressure reveals a phase transition from an in-plane 2x2 commensurate potassium superstructure to a new ..sqrt..3x..sqrt..3 commensurate superstructure. This is the first such transition to be observed; it is related to the recently discovered staging transition of KC/sub 8/ under pressure. In addition this staging transition was observed to occur more slowly and at much lower pressures than in the reported neutron-scattering experiment on highly oriented pyrolytic graphite samples. 13 references, 2 figures.
1985-05-15
ROSAT observations of the RSCVn binary sigma Geminorum
DEFF Research Database (Denmark)
X-ray observations of the RSCVn system sigma Geminorum have been undertaken with the ROSAT observatory. Several spectra of very good signal-to-noise ratio were obtained. Spectral fitting using metal abundances amounting to 50% of solar values reveal two temperature components at 2 MK and 12 MK. Previous EXOSAT observations showed another component at 40 MK. Particular interest is focused on the temporal variations of the X-ray emission. It is found that variations occur on time scales ranging from years to hours and minutes.
1997-01-01
M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies
International Nuclear Information System (INIS)
M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell ...
Direct chemical information from special radiotracers as well as from outer X-ray excitation
Energy Technology Data Exchange (ETDEWEB)
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray ...
1983-09-01
Direct chemical information from special radiotracers as well as from outer X-ray excitation
International Nuclear Information System (INIS)
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ...
1982-10-01
Exploring the Physics of Type Ia Supernovae Through the X-ray Spectra of their Remnants
We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-ray emission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
2008-12-15
International Nuclear Information System (INIS)
Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.
2005-04-01
Simulation Studies of the X-Ray Free-Electron Laser Oscillator
Energy Technology Data Exchange (ETDEWEB)
Simulations of the x-ray free-electron laser (FEL) oscillator are presented that include transverse effects and realistic Bragg crystal properties with the two-dimensional code GINGER. In the present cases considered the radiation divergence is much narrower than the crystal acceptance, and the numerical algorithm can be simplified by ignoring the finite angular bandwidth of the crystal. In this regime GINGER shows that the saturated x-ray pulses have 109 photons and are nearly Fourier-limited with peak powers in excess of 1 MW. Wealso include preliminary results for a four-mirror cavity that can be tuned in wavelength over a few percent, with future plans to incorporate the full transverse response of the Bragg crystals into GINGER to more accurately model this tunable source.
2009-08-14
Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser
Energy Technology Data Exchange (ETDEWEB)
A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.
2009-12-11
Characterisation and use of biomass fly ash in cement-based materials
British Library Electronic Table of Contents (United Kingdom)
This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...
2009-01-01
A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity
International Nuclear Information System (INIS)
Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.
1988-01-14
Energy Technology Data Exchange (ETDEWEB)
The transformation of Pd/Si to Pd{sub 2}Si/Si is investigated using depth-resolved positron annihilation, x-ray diffraction and Auger electron spectroscopy studies. The observed defect-sensitive positron S-parameter value of 1.022-1.054 indicates the existence of divacancies across the silicide/silicon interface and Si substrate region. Our experimental observation of vacancy defects is consistent with the model proposed for excess vacancy generation across the interface consequent to Si diffusion. (letter to the editor)
2003-11-26
Observing the Sunyaev-Zel'dovich Effect Closer to Home
Hot gas trapped in a dark matter halo will produce a decrement in the surface brightness of the microwave background, the Sunyaev-Zel'dovich (SZ) effect. While massive clusters produce the strongest central SZ decrements, we point out that a local galaxy halo, specifically the halo of M31, may be one of the brightest integrated SZ sources in the sky. For various realistic gas distributions consistent with current X-ray limits, we show that the integrated SZ decrement from M31 will be comparable to decrements already detected in more distant sources, provided its halo contains an appreciable quantity of hot gas. A measurement of this decrement would provide direct information on the mass, spatial distribution and thermodynamic state of hot gas in a low-mass halo, and could place important constraints on current models of galaxy formation. Detecting such an extended (~ 10 degree), low-amplitude signal will be challenging, but ...
2003-01-01
We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of ...
2010-01-01
Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
1977-01-01
LCLS XTOD Tunnel Vacuum System (XVTS)
Energy Technology Data Exchange (ETDEWEB)
The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.
2005-11-04
K_#beta#/K_#alpha# X-ray intensity ratio following K-electron capture and radioisotope excitation
International Nuclear Information System (INIS)
The K_#beta#/K_#alpha# X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49<=Z<=82 following electron capture decay and photon excitation using "2"4"1Am and "5"7Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K_#beta#/K_#alpha# values on the mode of excitation in the case of Mn and Fe is attribuited to the chemical effects, while no such dependence is found for the high-Z elements.
1987-01-01
Identification of elements in plant drugs and their water infusion using X-ray fluorescence analysis
International Nuclear Information System (INIS)
The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.
8100-01-01
Electron temperature diagnostics in the RFX reversed field pinch experiment
Energy Technology Data Exchange (ETDEWEB)
The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)
2000-08-01
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.
1994-01-01
Application of 10 GeV electron driven x-ray laser in gamma-ray laser research
Energy Technology Data Exchange (ETDEWEB)
The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize [gamma]-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.
1992-01-01
Application of 10 GeV electron driven x-ray laser in gamma-ray laser research
Energy Technology Data Exchange (ETDEWEB)
The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize {gamma}-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.
1992-12-01
A Chandra Observation of Supernova Remnant G350.1-0.3 and Its Central Compact Object
We present a new Chandra observation of supernova remnant (SNR) G350.1-0.3. The high resolution X-ray data reveal previously unresolved filamentary structures and allow us to perform detailed spectroscopy in the diffuse regions of this SNR. Spectral analysis demonstrates that the region of brightest emission is dominated by hot, metal-rich ejecta while the ambient material along the perimeter of the ejecta region and throughout the remnant's western half is mostly low-temperature, shocked interstellar/circumstellar medium (ISM/CSM) with solar-type composition. The data reveal that the emission extends far to the west of the ejecta region and imply a lower limit of 6.6 pc on the diameter of the source (at a distance of 4.5 kpc). We show that G350.1-0.3 is likely in the free expansion (ejecta-dominated) stage and calculate an age of 600-1200 years. The derived relationship between the shock velocity and the electron/proton ...
2011-01-01
Future metrology needs for FEL reflective optics.
Energy Technology Data Exchange (ETDEWEB)
An International Workshop on Metrology for X-ray and Neutron Optics has been held March 16-17, 2000, at the Advanced Photon Source, Argonne National Laboratory, near Chicago, Illinois (USA). The workshop gathered engineers and scientists from both the U.S. and around the world to evaluate metrology instrumentation and methods used to characterize surface figure and finish for long grazing incidence optics used in beamlines at synchrotrons radiation sources. This two-day workshop was motivated by the rapid evolution in the performance of x-ray and neutron sources along with requirements in optics figure and finish. More specifically, the performance of future light sources, such as free-electron laser (FEL)-based x-ray sources, is being pushed to new limits in term of both brilliance and coherence. As a consequence, ...
2000-09-21
The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.
2003-01-01
Studies of L x-rays from 64 MeV iodine projectiles in collision with gas targets
International Nuclear Information System (INIS)
We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)
1997-11-17
Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+
British Library Electronic Table of Contents (United Kingdom)
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
2009-01-01
K-edge X-ray absorption spectra of argon in sputtered aluminum films
International Nuclear Information System (INIS)
We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
1999-01-04
Cluster Geometry & Inclinations from Deprojection Uncertainties
{The determination of cluster masses is a complex problem that would be aided by information about the cluster shape and orientation (along the line-of-sight).} {It is in this context, that we have developed a scheme for identifying the intrinsic morphology and inclination of a cluster, by looking for the signature of the true cluster characteristics in the inter-comparison of the different deprojected emissivity profiles (that all project to the same X-ray brightness distribution) and by using SZe data when available.} {We deproject the cluster X-ray surface brightness profile under the assumptions of four different geometry and inclination configurations for the observed system; these 4 configurations correspond to four extreme geometry+inclination scenarios. The deprojection in question is performed by the non-parametric algorithm DOPING. The formalism is tested with model systems and then is applied to a sample of 24 ...
2008-01-01
Association of brain cancer with dental x-rays and occupation in Missouri
International Nuclear Information System (INIS)
This investigation of a brain cancer cluster in Missouri used two approaches to investigate associations with potential risk factors. In a case-control study in a rural town, we interviewed surrogates of cases and controls about potential risk factors. We found a statistically significant positive association of brain cancer with reported exposure to dental x-rays. Occupation was not associated with the cluster in the rural town. In a standardized proportional mortality study for the state of Missouri, we calculated the observed and expected proportion of brain cancers by occupation and industry in Missouri decedents. We found that motor vehicle manufacturers, beauty shop workers, managers and administrators, elementary school teachers, and hairdressers and cosmetologists had significantly elevated proportions of brain cancer. Brain tumors are inconsistently associated with occupation in the literature. Further study of brain cancer etiology ...
1991-01-01
British Library Electronic Table of Contents (United Kingdom)
We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-ray induced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...
2010-01-01
Observed energy dependence of Fano factor in silicon at hard X-ray energies
Energy Technology Data Exchange (ETDEWEB)
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
1999-03-01
Grain boundary transport in x-ray irradiated polycrystalline diamond
International Nuclear Information System (INIS)
The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the ...
2003-05-15
A Distinctive Disk-Jet Coupling in the Seyfert-1 AGN NGC 4051
We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this ...
2010-01-01
Use of X-ray fluorescence analysis in the study of archeological samples
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis (XFA) was used in the determination of the contents of metal residues in dosing plates for coin minting. XFA was also used for the determination of the strontium/calcium ratio in bone samples of different animals with the aim to obtain information on the food composition of these animals. It was found that bones of different animals can be distinguished based on the Sr/Ca ratio. No significant differences in the Sr/Ca ratio were observed in human bones of individuals from different social groups. (author). 1 fig., 5 tabs., 4 refs.
1988-09-26
Sunyaev-Zel'dovich Effects from Quasars Shining in Galaxies and Groups
The energy fed by active galactic nuclei to the surrounding diffuse baryons changes the latter's amount, temperature, and distribution; so in groups and in member galaxies it affects the X-ray luminosity and also the Sunyaev-Zel'dovich effect. Here we compute how the latter is enhanced by the transient blastwave driven by a shining quasar, and is depressed when the equilibrium is recovered with a depleted density. We constrain such depressions and enhancements with the masses of relic black holes in galaxies and the X-ray luminosities in groups. We discuss how all these linked observables can tell the quasar contribution to the thermal history of the baryons pervading galaxies and groups.
2003-01-01
International Nuclear Information System (INIS)
The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.
Energy Technology Data Exchange (ETDEWEB)
The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.
1986-07-07
Energy Technology Data Exchange (ETDEWEB)
Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for ...
2002-10-01
International Nuclear Information System (INIS)
K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, except for Cr in ...
2002-10-01
International Nuclear Information System (INIS)
K#beta#-to-K#alpha# x-ray intensity ratios of Fe and Ni in pure metals and in Fe_xNi_1_-_x alloys (x=0.20, 0.50, 0.58) exhibiting similar crystalline structure have been measured following excitation by 59.54 keV #gamma# rays from a 200 mCi "2"4"1Am point source to understand why the properties of the Fe_xNi_1_-_x (x=0.2) alloy are distinct from other alloy compositions. The valence electronic structure of Fe and Ni in the samples has been evaluated by comparing the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations. Significant changes in the 3d electron population (with respect to the pure metal) are observed for Fe and Ni for certain alloy compositions. These changes can be explained by assuming rearrangement of electrons between 3d and (4s,4p) band states of the individual metal atoms. It has been found that the valence electronic structure of the ...
2001-02-15
Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals
British Library Electronic Table of Contents (United Kingdom)
The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...
2010-01-01
radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...
Real-time orbit feedback at the APS.
Energy Technology Data Exchange (ETDEWEB)
A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in ...
1998-06-18
Fundamental limits on beam stability at the advanced photon source
International Nuclear Information System (INIS)
Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.
1998-12-10
Turnover of texture in low rate sputter-deposited nanocrystalline molybdenum films
International Nuclear Information System (INIS)
The crystallite size and orientation in molybdenum films prepared by magnetron sputtering at a low rate of typical 1 (angstrom)s and a pressure of 0.45 Pa was investigated by X-ray diffraction and texture analysis. The surface topography was studied using atomic force microscopy. Increasing the film thickness from 20 nm to 3 microm, the films show a turnover from a (110) fiber texture to a (211) mosaic-like texture. In the early state of growth (20 nm thickness) the development of dome-like structures on the surface is observed. The number of these structures increases with film thickness, whereas their size is weakly influenced. The effect of texture turnover is reduced by increasing the deposition rate by a factor of six, and it is absent for samples mounted above the center of the magnetron source. The effect of texture turnover is related to the bombardment of the films with high energetic argon neutrals resulting from ...
1997-04-04
The formation mechanism of textured YBa sub 2 Cu sub 3 O sub 7-. delta
Energy Technology Data Exchange (ETDEWEB)
The formation of textured YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (123) from a liquid phase according to the peritectic reaction Y{sub 2}BaCuO{sub 5} (211) + liquid {yields} 123 was analyzed using real-time analysis techniques of high-temperature X-ray diffraction, high-temperature optical microscopy, and environmental scanning electron microscopy (ESEM). Results were coupled with conventional ''post-mortem'' SEM analysis of processed samples at various stages of microstructural development. Observations of 123 formation and growth from the peritectic melt permit the conclusion that the presence of crystalline 211 primarily acts as a source of yttrium. The slow dissolution of 211 into the yttrium deficient liquid phase is the rate controlled step in the formation and growth of the textured 123, rather that its acting as a nucleation site for 123 grains as has been widely assumed. (orig.).
1992-05-20
Study of porous silicon morphologies for electron transport
International Nuclear Information System (INIS)
Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns ...
1993-05-17
Energy Technology Data Exchange (ETDEWEB)
Strain-induced crystallization of crosslinked natural rubber (NR) and its synthetic analogue, cis-1,4-polyisoprene (IR), both mixed with various amounts of stearic acid (SA), were investigated by time-resolved X-ray diffraction using a powerful synchrotron radiation source and simultaneous mechanical (tensile) measurement. No acceleration or retardation was observed on NR in spite of the increase of SA amount. Even the SA-free IR crystallized upon stretching, and the overall crystallization behavior of IR shifted to the larger strain ratio with increasing SA content. No difference due to the SA was detected in the deformation of crystal lattice by stress for both NR and IR. These results suggested that the extended network chains are effective for the initiation of crystallization upon stretching, while the role of SA is trivial. These behaviors are much different from their crystallization at low temperature by standing, ...
2007-01-01
Is the Supernova Remnant RX J1713.7-3946 a Hadronic Cosmic Ray Accelerator ?
The non-thermal supernova remnant RX J1713.7-3946 (G347.3-0.5) has recently been shown to be a site of cosmic ray (CR) electron acceleration to TeV energies (Muraishi et al. 2000). Here we present evidence that this remnant is also accelerating CR nuclei. Such nuclei can interact with ambient interstellar gas to produce high energy gamma-rays via the decay of neutral pions. We associate the unidentified EGRET GeV gamma- ray source 3EG J1714-3857 with a massive (~3*10 5 Mo) and dense (~500 nucleons cm -3) molecular cloud interacting with RX J1713.7-3946. Direct evidence for such interaction is provided by observations of the lowest two rotational transitions of CO in the cloud; as in other clear cases of interaction, the CO(J=2-1)/CO(J=1-0) ratio is significantly enhanced. Since the cloud is of low radio and X-ray brightness, CR electrons cannot be responsible for the bulk of its GeV emission there. A picture thus emerges ...
2001-01-01
Extended Gas in Seyfert Galaxies Near Infrared Observations of NGC 2110 and Circinus
We present results of near--IR long-slit spectroscopy in the J and K bands of the Seyfert 2 galaxies NGC 2110 and Circinus, investigating the gaseous distribution, excitation, reddening and kinematics. In NGC 2110, the emission line ratio [FeII]/Pa beta increases towards the nucleus (to ~ 7). The nuclear [Fe II]1.257 (microns) and Pa beta lines are broader (FWHM ~ 500 km/s) than the H2 (2.121) line (FWHM ~ 300 km/s). Both these results suggest that shocks, driven by the radio jet, are an important source of excitation of [Fe II]. The H2 excitation appears to be dominated by X-rays from the nucleus. In Circinus, both [FeII]/Pa beta and H2/Br gamma decrease from ~ 2 at 4 arcsec from the nucleus to nuclear values of ~ 0.6 and ~ 1, respectively, suggesting that the starburst dominates the nuclear excitation, while the AGN dominates the excitation further out (r > 2 arcsec). For both galaxies, the gaseous kinematics are consistent with circular ...
1998-01-01
Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer
International Nuclear Information System (INIS)
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
1984-10-01
International Nuclear Information System (INIS)
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
1984-01-01
Swift panchromatic observations of the bright gamma-ray burst GRB050525a
The bright gamma-ray burst GRB050525a has been detected with the Swift observatory, providing unique multiwavelength coverage from the very earliest phases of the burst. The X-ray and optical/UV afterglow decay light curves both exhibit a steeper slope ~0.15 days after the burst, indicative of a jet break. The timing of the jet break combined with the total gamma-ray energy of the burst constrains the opening angle of the jet to be 2.5 degrees. We derive an empirical `time-lag' redshift from the BAT data of z_hat = 0.69 +/- 0.02, in good agreement with the spectroscopic redshift of 0.61. Prior to the jet break, the X-ray data can be modelled by a simple power law with index alpha = -1.2. However after 300s the X-ray flux brightens by about 30% compared to the power-law fit. The optical/UV data have a more complex decay, with evidence of a rapidly falling reverse shock component that dominates in the first minute or so, ...
2006-01-01
Probing the Origins of the CIV and Fe Kalpha Baldwin Effect
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft ...
2009-01-01
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available ...
2008-05-22
Ion-induced M X-ray emission from heavy lanthanides
Energy Technology Data Exchange (ETDEWEB)
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.
1987-12-01
Energy Technology Data Exchange (ETDEWEB)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection ...
1994-10-01
International Nuclear Information System (INIS)
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection ...
1994-01-01
Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films
Energy Technology Data Exchange (ETDEWEB)
Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray ...
2008-12-15
Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films
International Nuclear Information System (INIS)
FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin ...
2008-12-01
Transverse Coherence Properties of the LCLS X-Ray Beam
Self-amplifying spontaneous radiation free-electron lasers, such as the LCLS or the European X-FEL, rely on the incoherent, spontaneous radiation as the seed for the amplifying process. Though this method overcomes the need for an external seed source one drawback is the incoherence of the effective seed signal. The FEL process allows for a natural growth of the coherence because the radiation phase information is spread out within the bunch due to slippage and diffraction of the radiation field. However, at short wavelengths this spreading is not sufficient to achieve complete coherence. In this presentation we report on the results of numerical simulations of the LCLS X-ray FEL. From the obtained radiation field distribution the coherence properties are extracted to help to characterize the FEL as a light source.
2007-04-16
Instruments for X-ray fluorescence analysis and spectrometry
International Nuclear Information System (INIS)
The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.
Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign
We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the ...
2010-01-01
The search for decaying Dark Matter
We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In ...
2009-01-01
Modification of surface texture by grinding and polishing lead zirconate titanate ceramics
Energy Technology Data Exchange (ETDEWEB)
This paper reports that grinding and polishing affected the orientation of 90[degrees] domains at the surface of lead zirconate titanate (PZT) ceramics. This was quantified by using changes in the intensity ratio of the (002) and (200) X-ray reflections. Grinding unpoled PZT with 600-grit SiC paper gave X-ray intensity ratios similar to those of poled material. This implies that 90[degrees] domain realignments had occurred in the near surface region probed by the X-rays. Grinding poled samples with 600-grit SiC further increased the X-ray intensity ratio beyond that caused by poling, indicating that additional surface reorientation of 90[degrees] domains had occurred. The effects of diamond polishing depended on the size of the diamond particles. The use of 6-[mu]m diamond had no effect on the (002)/(200) intensity ratio of either poled or unpoled samples, while polishing with 15- or 45-[mu]m diamond ...
1992-08-01
Modification of surface texture by grinding and polishing lead zirconate titanate ceramics
International Nuclear Information System (INIS)
This paper reports that grinding and polishing affected the orientation of 90 degrees domains at the surface of lead zirconate titanate (PZT) ceramics. This was quantified by using changes in the intensity ratio of the (002) and (200) X-ray reflections. Grinding unpoled PZT with 600-grit SiC paper gave X-ray intensity ratios similar to those of poled material. This implies that 90 degrees domain realignments had occurred in the near surface region probed by the X-rays. Grinding poled samples with 600-grit SiC further increased the X-ray intensity ratio beyond that caused by poling, indicating that additional surface reorientation of 90 degrees domains had occurred. The effects of diamond polishing depended on the size of the diamond particles. The use of 6-#mu#m diamond had no effect on the (002)/(200) intensity ratio of either poled or unpoled samples, while polishing with 15- or 45-#mu#m diamond ...
1992-01-01
International Nuclear Information System (INIS)
The purpose of this research is to investigate the micro-mechanism of deformation behavior of metallic glasses. We report the results of direct observations of short-range and medium-range structural change during tensile deformation of metallic glasses by high energy X-ray diffraction method. Cu50Zr50 and Ni30Zr70 metallic glass samples in the ribbon shape (1.5 mm width and 25 ?m) were made by using rapid quenching method. Tensile deformation added to the sample was made by using special equipment adopted for measuring the high energy X-ray diffraction. The peaks in pair distribution function g(r) for Cu50Zr50 and N30iZr70 metallic glasses move zigzag into front and into rear during tensile deformation. These results of direct observation on atomic distribution change for Cu50Zr50 and Ni30Zr70 metallic glass ribbons during tensile deformation suggest that the micro-relaxations occur.
2009-08-26
X-Ray Fluorescence Analysis of Composite Propellants for ...
... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...
1977-06-03
The principles of radionuclide excitation of X-ray fluorescence radiation and its application in
1972-01-01
This investigation describes the technique for the detection of the X-ray fluorescent radiation
1972-01-01
Determination of the Sr/Ca ratio in bones by XRFA
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis was used for the determination of Sr/Ca ratio in bones to test the influence of a diet on this ratio. Significant differences were observed for Sr/Ca ratio in bones of various animals. Only small differences in the Ca/Sr ratio were observed for the samples of various prehistoric human bones. (author) 4 refs.; 4 tabs.
1989-11-01
International Nuclear Information System (INIS)
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
1999-01-01
[Dependence of scattered Mn K alpha / K beta X-ray intensity ratio on the scatterer materials].
The K alpha / K beta ratio of Mn KX-rays scattered by metallic samples changed remarkably with the geometry between the sample and the (55)Fe source-Si(Li) detector system. On the contrary, this intensity ratio changed little in the cases of non-metallic scatterer samples such as lucite or mylar. This difference is interpreted as due to the occurrence of strong or weak interference in the coherent scattering photons. PMID:7280291
1980-10-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
International Nuclear Information System (INIS)
Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.
1983-01-01
International Nuclear Information System (INIS)
Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).
1983-01-01
Determination of heavy metals in welders' working environment using nuclear analytical methods
International Nuclear Information System (INIS)
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).
1985-01-01
Determination of heavy metals in welders' working environment using nuclear analytical methods
Energy Technology Data Exchange (ETDEWEB)
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.
1985-01-03
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.
1994-03-01
Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production
International Nuclear Information System (INIS)
An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. ...
1995-03-11
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. ...
1995-03-01
Absorption Features in Spectra of Magnetized Neutron Stars
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be ...
2010-01-01
A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE
International Nuclear Information System (INIS)
We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting particles. Our spectral ...
2010-06-01
International Nuclear Information System (INIS)
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.
Strain and Texture in Al-Interconnect Wires Measured by X-Ray Microbeam Diffraction
Energy Technology Data Exchange (ETDEWEB)
The local strain and texture in Al interconnect wires have been investigated using white and monochromatic x-ray microbeams on the MHATTCAT undulator beam line at the Advanced Photon Source. Intergrain and intragrain orientations were obtained with ~0.01 degree sensitivity using white beam measurements on wide Al pads (~100 Mu-m) and thin (2 Mu-m) Al wires. Orientation changes of up to 1 degree were found within individual grains of the (111) textured Al interconnects. Deviatoric strain measurements indicate small intragranular strain variations, but intergranular strain variations were found to be quite large.
1999-04-05
Energy Technology Data Exchange (ETDEWEB)
The K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49 less than or equal to Z less than or equal to 82 following electron capture decay and photon excitation using /sup 241/Am and /sup 57/Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K/sub ..beta..//K/sub ..cap alpha../ values on the mode of excitation in the case of Mn and Fe is attributed to chemical effects, while no such dependence is found for the high-Z elements.
1987-01-01
Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)
Energy Technology Data Exchange (ETDEWEB)
The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.
1993-05-01
Effects of Tapered Betafunction in the LCLS Undulators
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is an X-ray free-electron laser (FEL) project based on the SLAC linac [1]. With its nominal set of electron beam, focusing and undulator parameters, it is designed to achieve SASE saturation at an undulator length of about 100 m with an average power of 10 GW. In order to keep the electron beam focused in the undulators, a FODO lattice is integrated along the entire length of the undulators. Nominally, the quadrupole strengths are chosen to produce nearly constant betafunction and beam size along the undulator, optimized for the FEL interaction in the exponential growth regime. Since these quadrupoles are electromagnetic, it is possible to adjust the individual quadrupole strength to vary the betafunction and the beam size along the undulator, tailoring the FEL interaction in the start-up and the saturation regimes. In this paper, we present simulation studies of the tapered betafunction in the LCLS ...
2005-09-30
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
Energy Technology Data Exchange (ETDEWEB)
We present high-quality X-ray scattering experiments on pure water taken over a temperature range of 2 to 77 C using a synchrotron beam line at the advanced light source (ALS) at Lawrence Berkeley National Laboratory. The ALS X-ray scattering intensities are qualitatively different in trend of maximum intensity over this temperature range compared to older X-ray experiments. While the common procedure is to report both the intensity curve and radial distribution function(s), the proper extraction of the real-space pair correlation functions from the experimental scattering is very difficult due to uncertainty introduced in the experimental corrections, the proper weighting of OO, OH, and HH contributions, and numerical problems of Fourier transforming truncated data in Q-space. Instead, we consider the direct calculation of X-ray scattering spectra using electron densities derived ...
2003-03-01
Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube
Energy Technology Data Exchange (ETDEWEB)
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...
2008-12-15
X-Ray Fluorescence in Research on the Cultural Heritage
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-15
X-Ray Fluorescence in Research on the Cultural Heritage
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
2001-09-01
Energy Technology Data Exchange (ETDEWEB)
One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be ...
2007-07-01
IN VACUUM UNDULATOR TASK FORCE REPORT
Energy Technology Data Exchange (ETDEWEB)
The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the electron beam is very ...
1998-06-01
Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam
International Nuclear Information System (INIS)
Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to that used for electron ...
1999-05-21
Application of radionuclide X-ray fluorescence analysis to the monitoring of the quality of air
International Nuclear Information System (INIS)
An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed ...
1990-10-01
International Nuclear Information System (INIS)
The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal ...
2010-06-15
International Nuclear Information System (INIS)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen ...
2010-06-01
Ionizing radiation-induced mutation of human cells with different DNA repair capacities
Energy Technology Data Exchange (ETDEWEB)
We have observed significant differences in the response to ionizing radiation of two closely related human cell lines, and now compare the effects on these lines of both low and intermediate LET radiation. Compared to TK6, WTK1 has an enhanced X-ray survival, and is also more resistant to cell killing by {alpha}-particles. The hprt locus is more mutable in WTK1 than in TK6 by both X-rays and {alpha}-particles. WTK1 is also more mutable by {alpha}-particles than by X-rays at the hprt locus. X-ray-induced mutation at the heterozygous tk locus in WTK1 is about 25 fold higher than in TK6, while {alpha}-particle-induced mutation is nearly 50 fold higher at this locus. Also, the slowly growing tk- mutants, which comprise the majority of spontaneous and X-ray-induced tk- mutants of TK6, were not induced significantly by {alpha}-particles. Previously, we showed that ...
1994-12-31
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Under changing redox conditions some plants create plaques at their root surface, which may affect the mobility and uptake of As and heavy metals but it is unknown to what extent this also holds true for willows in contaminated floodplain soils. Therefore, willow roots were sampled from a phytoremediation trial in the contaminated floodplain of the river Elbe (Germany), cryofixed, freeze-dried, and cross sections were mapped for the distribution of As, Ca, Cu, Fe, K, Mn, Ni, S and Zn by synchrotron based X-ray fluorescence spectroscopy. The elements Ca, Cu, Ni, S and Zn were concentrated in the aerenchymatic tissue, and not associated with Fe and Mn. Mixed Fe-Mn plaques covered the surface of the willow roots and As was accumulated in these plaques. The observed association pattern between...
2011-01-01
SPH simulations of accretion flow via Roche lobe overflow and via mass transfer from Be disk
We compare the accretion flow onto the neutron star induced by Roche lobe overflow with that by the overflow from the Be disk, in a zero eccentricity, short period binary with the same mass transfer rate, performing three-dimensional Smoothed Particle Hydrodynamics simulations. We find that a persistent accretion disk is formed around the neutron star in both cases. The circularization radius of the material transferred via Roche lobe overflow is larger than that of the material transfered from the Be disk. Thus, the growth of the accretion disk in the former case becomes significantly slower than in the latter case. In both cases, the mass accretion rate is very small and varies little with orbital phase, which is consistent with the observed X-ray behaviour of Be/X-ray binaries with circular orbits (e.g. XTE J1543-568).
2005-01-01
Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering
Energy Technology Data Exchange (ETDEWEB)
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
2005-07-01
Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)
Energy Technology Data Exchange (ETDEWEB)
Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).
1991-01-01
Corrosion of gold bridgewire in electronic components
Energy Technology Data Exchange (ETDEWEB)
Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion product and degradation of the plastic header.
1986-01-01
Constraining SN Ia Models Using X-ray Spectra of Clusters of Galaxies
We present constraints on theoretical models of Type Ia SNe using spatially resolved ASCA X-ray spectroscopy of four galaxy clusters: Abell 496, Abell 2199, Abell 3571 & Perseus. All four clusters have central Fe abundance enhancements and an ensemble of abundance ratios are used to show that most of the Fe in the central regions of the clusters comes from SN Ia. At the center of each cluster, simultaneous analysis of spectra from all ASCA instruments shows that the Ni to Fe abundance ratio (normalized by the solar ratio) is ~ 4. We use the Ni/Fe ratio as a discriminator between SN Ia explosion models: the Ni/Fe ratio of ejecta from the "Convective Deflagration" model W7 is consistent with the observations, while those of "delayed detonation" models are not consistent at the 90% confidence level.
2000-01-01
International Nuclear Information System (INIS)
The structural parameters of various Haegg phases (H or M_n_+_1AX_n phases) are studied experimentally by x-ray and electron spectroscopies, x-ray diffraction, and ab initio full potential as well as full mutiple scattering theoretical calculations. Experimentally it was found that the structure of all ternary compounds analyzed herein are relaxed. The values of the lattice parameters and relaxations obtained from ab initio calculations are in excellent agreement with those deduced from the analysis of the experimental data. The bonding scheme has been analyzed and the charge transfer between constituting atoms determined. It is demonstrated that the strength and electrical transport properties in these materials are principally governed by the metallic planes. For the solid solution (Ti_0_._5Nb_0_._5)_2AlC, the most salient result is that the basal planes are corrugated, which could explain the solid solution scattering ...
2005-01-01
Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the determination of the Sn mass in ...
2004-01-01
The impact of accretion disk winds on the X-ray spectrum of AGN: Part 1 - XSCORT
(abridged) The accretion disk in AGN is expected to produce strong outflows, in particular a UV-line driven wind. Despite providing a good fit to the data, current spectral models of the X-ray spectrum of AGN observed through an accretion disk wind are ad-hoc in their treatment of the properties of the wind material. In order to address these limitations we adopt a numerical computation method that links a series of radiative transfer calculations, incorporating the effect of a global velocity field in a self-consistent manner (XSCORT). We present a series of example spectra from the XSCORT code that allow us to examine the shape of AGN X-ray spectra seen through a wind, for a range of velocity and density distributions, total column densities and initial ionization parameters. These detailed spectral models clearly show considerable complexity and structure that is strongly affected by all these factors. The presence of ...
2007-01-01
International Nuclear Information System (INIS)
Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal ...
1988-08-15
International Nuclear Information System (INIS)
Iron oxide thin films were prepared by spray pyrolysis technique onto glass substrates from iron chloride solution. They were characterized by X-ray diffractometry (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and (UV-vis) spectroscopy. The films deposited at T _s #<=# 450 deg. C were amorphous; while those produced at T _s_u_b = 500 deg. C were polycrystalline #alpha#-Fe_2O_3 with a preferential orientation along the (1 0 4) direction. By observing scanning electron microscopy (SEM), it was seen that iron oxide films were relatively homogeneous uniform and had a good adherence to the glass substrates. The grain size was found (by RX) between 19 and 25 nm. The composition of these films was examined by X-ray photoelectron spectroscopy and electron probe microanalysis (EPMA). These films exhibited also a transmittance value about 80% in the visible and infrared ...
2006-12-15
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-15
Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization
International Nuclear Information System (INIS)
The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.
2007-01-01
Extreme Ultraviolet Emission from Abell 4059
We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 ...
2000-01-01
International Nuclear Information System (INIS)
Glasses in the system (1 - x) [29Na2O- 4Al2O3- 67B2O3]- xZnO (0 ? x ? 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of Zn-O in place of ...
2009-05-05
Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with ...
2008-01-01
International Nuclear Information System (INIS)
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
1974-12-03
Linac Coherent Light Source (LCLS) Bunch-Length Monitor using Coherent Radiation
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. One of the most critical diagnostic devices is the bunch length monitor (BLM), which is to be installed right after each compressor utilizing coherent radiation from the last bending magnet. We describe the components and the optical layout of such a BLM. Based on the setup geometry, we discuss some issues about the coherent radiation signal.
2007-03-21
International Nuclear Information System (INIS)
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
2001-09-23
Mechanisms of the pulse rise-time variations in X-ray proportional counters
Energy Technology Data Exchange (ETDEWEB)
The paper presents a description of the physical processes governing the variations of the pulse rise-time which occur during the operation of the proportional counter and are due to varying either the count rate or the applied voltage. On the basis of the rise-time concept the differences in the count rate effect observed in various types of proportional counters are discussed.
1981-01-01
Influence of electric-field is on luminescence of ZnSe
International Nuclear Information System (INIS)
The results of experimental researches of photoluminescence and X-ray luminescence in crystal ZnSe are presented at the different values of tension of electric-field to samples. Observed, that the electric field changes both intensity of stationary luminescence and form of bars in the spectrums of luminescence. At the saliatory change of difference of potentials on the electrodes of crystal in luminescence there are of long duration relaxation processes character of which substantially depends on the type of excitation of standard.
Inertinite of fossil coal and molecular paleontology
British Library Electronic Table of Contents (United Kingdom)
The etching method developed made it possible to observe under the microscope the finest components of the anatomical structure of coal-forming plants. The dependence of the effectiveness of etching of tissues on the concentrations of geopolymers (protocellulose and protolignin) in them was found. The study of tissues of this kind by the methods of local analysis (for example, X-ray microanalysis) allowed us to obtain the characteristics of the above geopolymers and to use them for the identification of the primary biochemical composition of fossil organic matter.
2011-01-01
International Nuclear Information System (INIS)
Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum ...
2004-08-23
Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V
Energy Technology Data Exchange (ETDEWEB)
Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...
2006-09-25
Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V
International Nuclear Information System (INIS)
Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using ...
2006-09-25
International Nuclear Information System (INIS)
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and ...
2006-01-01
Central engine of quasars and AGNs: a relativistic proton radiative shock
International Nuclear Information System (INIS)
Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas (1984), if ...
1985-08-01
The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...
2005-07-01
THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 #<=# z #<=# 1.2
International Nuclear Information System (INIS)
We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical ...
2010-08-01
Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not ...
2010-01-01
Radioanalytical determination of chromium in welding fumes
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, ...
1985-01-01
Determination of small amounts of elements by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).
1975-01-01
PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS
International Nuclear Information System (INIS)
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, ...
2009-09-01
International Nuclear Information System (INIS)
Epidermal growth factor receptor (EGFR) gene alterations have been found in human lung cancers. However, there is no information on the factors inducing EGFR mutations. In rodents, K-ras mutations are frequently found in many lung carcinogenesis models, but hitherto, Egfr mutations have not been reported. Their presence was therefore investigated in representative lung carcinogenesis models with 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N-nitrosobis(2-hydroxypropyl)amine (BHP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MelQx) and ethyl carbamate (urethane), as well as X-ray irradiation. With the chemical carcinogenesis models, no mutations were detected in Egfr, which is in clear contrast to the high rates observed in either codon 12 or 61 of K-ras (21/23 of the lung tumors induced with NNK, 4/5 with MelQx, 1/4 with urethane and 7/18 with BHP). However, in the X-ray-induced lung tumors, Egfr mutations with ...
2008-02-01
Energy Technology Data Exchange (ETDEWEB)
X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG ...
2009-12-15
Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays
Energy Technology Data Exchange (ETDEWEB)
We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue ...
2005-10-11
UK PubMed Central (United Kingdom)
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
2010-05-01
Radionuclide X-ray fluorescence analysis with environmental application
International Nuclear Information System (INIS)
The purpose of this work is to present a comprehensive, instructive analysis of the basis of radionuclide XRFA, to describe methods of sample preparation for environmental analysis and to make the reader more familiar with the procedures, methods and instrumentation of radionuclide XRFA used in this field. This book discusses the use of radionuclide XRFA for solving analytical problems of the environment and information is presented concerning the current state of research and use of radionuclide XRFA in this significant area. The present volume will serve as a basic source of data and also as a laboratory handbook. refs.; figs.; tabs.
1990-01-01
Multielement XRF-analysis of blood from patients with dilated cardiomyopathy
International Nuclear Information System (INIS)
Radionuclide x-ray fluorescence analysis was used for the determination of Fe, Zn, Br and Rb levels in whole blood from dilated cardiomyopathy patients and from a control group. The XRF-system consisted of a radionuclide source "1"0"9Cd, a semiconductor Si/Li detector connected to a multichannel analyzer. Fe content in blood of patients was significantly lower than that of the control. Zn content showed no deviation from normal range. Values for Br and Rb in patients highly exceed the range reported for them. (author) 4 tabs.; 9 refs.
1991-03-01
High Exposure Facility Technical Description
Energy Technology Data Exchange (ETDEWEB)
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
2008-02-12
Free electron laser seeded by ir laser driven high-order harmonic generation
International Nuclear Information System (INIS)
Coherent x-ray production by a seeded free electron laser (FEL) is important for next generation synchrotron light sources. The authors examine the feasibility and features of FEL emission seeded by a high-order harmonic generation (HHG) of an infrared laser. In addition to the intrinsic FEL chirp, the longitudinal profile and spectral bandwidth of the HHG seed are modified significantly by the FEL interaction well before saturation. This smears out the original attosecond pulselet structure. The authors introduce criteria for this smearing effect on the pulselet and the stretching effect on the entire pulse. They discuss the noise issue in such a seeded FEL.
2007-01-08
Evolution of the white dwarf mass and spin in cataclysmic variables
International Nuclear Information System (INIS)
We consider the spin-up of the white dwarf in non-magnetic cataclysmic variables (CVs) during secular evolution. If this is unresisted, CVs are quenched as boundary-layer emitters once the binary period has decreased by #approx# 1 hr. Angular momentum loss in nova explosions may, however, prevent the star reaching breakup. If the explosions remove (1 + #epsilon#) x the mass accreted between outbursts, values 0.5 < #approx# #epsilon# < #approx# 1 allow CVs to be modest boundary-layer emitters for most of their lifetimes. Spectral effects will limit their detection as soft X-ray sources. (author).
Elemental concentration analysis in some plant samples by EDXRF at Trabzon
International Nuclear Information System (INIS)
The elemental analysis of some plant samples have been carried out in Trabzon region (Turkey) using energy-dispersive X-ray fluorescence (EDXRF) spectrometry. We have analyzed plant samples for nine stations using 1.85 GBq 55Fe radioactive sources. We have found that potassium and calcium within 0.3-1.4% and 0.3-2.8% were present in concentration in plants for every station, respectively. The concentration of Cl and Ti generally changed according to the plant species and the sampling station.
2006-12-01
International Nuclear Information System (INIS)
The K sub(#alpha#)/K sub(#beta#) intensity ratio of Mn KX-rays scattered by metallic samples changed remarkably with the geometry between the sample and the "5"5Fe source-Si(Li) detector system. On the contrary, this intensity ratio changed little in the cases of non-metallic scatterer samples such as lucite or mylar. This difference is interpreted as due to the occurrence of strong or weak interference in the coherent scattering photons. (author).
1980-01-01
Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.
2005-06-15
Energy Technology Data Exchange (ETDEWEB)
The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.
1983-05-01
International Nuclear Information System (INIS)
The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).
1983-01-01
Size-dependent surface plasmon resonance in silver silica nanocomposites
Energy Technology Data Exchange (ETDEWEB)
Silver silica nanocomposites were obtained by the sol-gel technique using tetraethyl orthosilicate (TEOS) and silver nitrate (AgNO{sub 3}) as precursors. The silver nitrate concentration was varied for obtaining composites with different nanoparticle sizes. The structural and microstructural properties were determined by x-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). X-ray photoelectron spectroscopic (XPS) studies were done for determining the chemical states of silver in the silica matrix. For the lowest AgNO{sub 3} concentration, monodispersed and spherical Ag crystallites, with an average diameter of 5 nm, were obtained. Grain growth and an increase in size distribution was observed for higher concentrations. The occurrence of surface plasmon resonance (SPR) bands and their evolution in the size range 5-10 nm is studied. For decreasing nanoparticle ...
2008-02-20
Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199
The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are ...
1999-01-01
Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique
International Nuclear Information System (INIS)
X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away from the negative O"2"- ions. It is concluded ...
2005-08-01
A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous ...
2000-05-01
Solid-state NMR and XRD study of #alpha#-SiAlON powders prepared by combustion synthesis
International Nuclear Information System (INIS)
"2"7Al and "2"9Si solid-state NMR spectra and X-ray diffraction (XRD) patterns were obtained for #alpha#-SiAlON powders prepared by combustion synthesis, according to which the phase transformation and structure evolution of #alpha#-SiAlON were studied. It was found that in #alpha#-SiAlON "2"9Si chemical shift values (-48 < #delta# _S_i < -47) were close to those in #beta#-Si_3N_4 and #alpha#-Si_3N_4, indicating that Si atoms kept SiN_4 coordination to a large extent in #alpha#-SiAlON despite the presence of O atoms. Dissimilarly, "2"7Al chemical shift values in #alpha#-SiAlON deviated clearly from that corresponding to AlN_4 coordination (#delta# _A_l #approx# 112) and occurred in a range from #delta# _A_l 95.5 to 99.9, which should be assigned to tetrahedral AlO _xN_4_-_x (0 #<=# x #<=# 4) coordination. The broadening effect of AlO _xN_4_-_x peaks was noticed, which was suggested to induced by slight dispersion of #alpha#-SiAlON compositions. "2"7Al ...
2007-07-31
Energy Technology Data Exchange (ETDEWEB)
Fuel irradiation leads to a swelling resulting from the formation of gaseous (Kr, Xe) or solid fission products which are found either in solution or as solid inclusions in the matrix. This phenomena has to be evaluated to be taken into account in fuel cladding Interaction. Fuel swelling was studied as a function of burn up by measuring the corresponding cell constant evolution by X-Ray diffraction. This study was realized on Mixed Oxide Fuels (MOX) irradiated in a Pressurized Water Reactor (PWR) at different burn-up for 3 initial Pu contents. Lattice parameter evolutions were followed as a function of burn-up for the irradiated fuel with and without an annealing thermal treatment. These experimental evolutions are compared to the theoretical evolutions calculated from the hard sphere model, using the fission product concentrations determined by the APPOLO computer code. Contribution of varying parameters influencing the unit cell value is discussed. Thermal ...
1995-07-01
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray ...
2008-05-22
M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium
International Nuclear Information System (INIS)
M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross ...
X-ray stars in globular clusters
The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)
1977-10-01
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
Position-sensitive proportional counter for space-based X-ray imaging studies
International Nuclear Information System (INIS)
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
2005-03-01
Beam-induced damage on diffractive hard X-ray optics
UK PubMed Central (United Kingdom)
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
2010-11-01
Gene rearrangement and radiation carcinogenesis
International Nuclear Information System (INIS)
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, ...
1993-11-01
Photoacoustic response to X-ray absorption in copper and brass
Energy Technology Data Exchange (ETDEWEB)
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).
1990-09-01
Energy Technology Data Exchange (ETDEWEB)
The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where the initiation of drug treatment succeeded the initiation of ...
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
International Nuclear Information System (INIS)
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
1995-09-01
Change in pore structure of coals by activation with KOH; KOH fukatsushita sekitan no saiko kozo
Energy Technology Data Exchange (ETDEWEB)
Three typical Japanese coals of non-coking coal, coking coal and anthracite were heat-treated with KOH, and change in their pore structure was examined by absorption of N2, X-ray diffraction and TEM observation. In addition, the relation between a coal rank and pore structure was also studied by absorption experiment of N2. In experiment, the mixture of coal and KOH in a nickel holder was heat-treated in N2 gas flow at heating rate of 2{degree}C/min, and held at a fixed temperature for one hour. To clarify the pore structure, N2 absorption isotherms were measured at -196{degree}C under nearly 76cmHg using a commercially available full-automatic absorption measurement equipment. Based on the X-ray diffraction and TEM observation results on activated coals, the relation between the N2 absorption and pore structure was studied. The results are summarized as follows: (1) The yield and absorption ability of ...
1996-10-28
x - NASA Technical Reports Server
Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...
International Nuclear Information System (INIS)
... obtain the film thickness for a given x-ray intensity ratio. 2.3 ANALYSING FOR
2000-08-01
NASA Technical Reports Server - Radionuclide X-ray fluorescence ...
Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.
A comparison of the X-ray properties of X Per and gamma Cas
Energy Technology Data Exchange (ETDEWEB)
The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.
1982-04-01
Structural origin of optical bowing in semiconductor alloys p
Energy Technology Data Exchange (ETDEWEB)
The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-ray absorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.
1983-08-22
Structural origin of optical bowing in semiconductor alloys p
International Nuclear Information System (INIS)
The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-ray absorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.
Recent observations of Cassiopeia A
International Nuclear Information System (INIS)
During the last few years radio and X-ray astronomers have produced high-resolution imagery of the remnant of Cas A. Since the most recent published optical photographs of Cas A date back to 1975 it seemed worthwhile to present new optical results based on plates obtained with the 5-m Hale telescope in 1976, 1977, and 1980. The major changes that have taken place in Cas A during the last decade are: (1) A broken shell of fast-moving knots has formed along the southern and SW rim of the remnant and (2) A number of blue (oxygen-rich) filaments have developed to the north of the centre of Cas A. (Auth.).
Projection techniques in diagnostic radiography discussed with regard to required dose
International Nuclear Information System (INIS)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
1990-09-01
Plasma nitriding of low alloy steels at floating and cathodic potentials
International Nuclear Information System (INIS)
The low alloy steels were nitrided in the plasma atmosphere generated by using hollow cathode discharge. For comparison, specimens of 40 Cr steel were in two different potential states. One kind is isolated from cathode and anode between them the discharge was created. The other kind is placed on the plate which is connected to the cathode. The nitriding was carried out at different temperatures. The surface morphology, phase of compound layers and microhardness profiles were analyzed. The optical microscopy observation and X-ray diffraction showed that the compound layers were formed in all experiments. The results of the nitriding treatment are weakly dependent on the potentials applied on the specimens.
2008-08-15
International Nuclear Information System (INIS)
Formation of the soft magnetic nanostructure in amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloy due to heat treatment is studied by the Moessbauer, differential scanning calorimetry, and X-ray diffraction techniques. Annealing at temperatures 520-580 "oC leads to the formation of extremely soft nanocrystalline alloy as revealed by the rf-Moessbauer measurements. The superparamagnetic behaviour was observed for the alloy annealed at 620-640 "oC. At higher annealing temperatures good soft magnetic properties deteriorate. (author)
2001-09-23
Atomic photoelectric effect near threshold edges
Energy Technology Data Exchange (ETDEWEB)
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub ..cap alpha..//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
1985-07-01
Atomic photoelectric effect near threshold edges
International Nuclear Information System (INIS)
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub #alpha#//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
1985-01-01
Anomaliously high radiation hardening of iron-chromium alloys
International Nuclear Information System (INIS)
Argon ions irradiation of 12% Cr steels and Fe/Cr alloys results in the hardening up to 10000 MPa. This value exceeds the hardening level even for martensitic transformation. Along with the increase of microhardness following irradiation the shape of X-ray graph of the affected materials changes considerable. Hardening value and behavior are determined by temperature radiation doze, preliminary ageing, extent of cold strain and alloying. The odserved phenomenon is supposed to be caused by irradiation-induced structural transformations. Reversibility of radiation hardening of the materials in question was observed.
Annealing, lattice disorder and non-Fermi liquid behavior in UCu4Pd
Energy Technology Data Exchange (ETDEWEB)
The magnetic and electronic properties of non-Fermi liquid UCu{sub 4Pd} depend on annealing conditions. Local structural changes due to this annealing are reported from UL{sub III}- and Pd K-edge x-ray absorption fine-structure measurements. In particular, annealing decreases the fraction of Pd atoms on nominally Cu 16e sites and the U-Cu pair-distance distribution width. This study provides quantitative information on the amount of disorder in UCu{sub 4Pd} and allows an assessment of its possible importance to the observed non-Fermi liquid behavior.
2002-07-30
An influence of ion bombardment on plasma nitriding process of Ti6Al14V alloy at 843 K temperature
International Nuclear Information System (INIS)
This work presents results of investigations on d.c. glow discharge nitriding of #alpha#+#beta# Ti-6Al-4V titanium alloy. The treatment was performed at 843 K in nitrogen-hydrogen atmosphere, pressure 300 Pa. Special attention was paid to nitriding mechanism and determination of the role of ion bombarding in nitriding process of titanium alloys. Produced as a result of d.c. plasma nitriding surface layers were subjected to macroscopic observations, microstructure studies, microhardness testing and X-ray analysis. (author)
2004-06-20
International Nuclear Information System (INIS)
The present document represents an attempt to summarize the most important features of the different forms of ED-XFR as applied to the analysis of airborne particulate matter. It is intended to serve as a set of guidelines for use by participants in the IAEA's own programmes, and other scientists, who are not yet fully experienced in the application of ED-XRF to airborne particulate samples, and who wish either to make a start on using this technique or to improve their existing procedures. The methodologies for sampling described in this document are of rather general applicability. Emphasis is also placed on the sources of errors affecting the sampling of airborne particulate matter. The analytical part of the document describes the different forms of ED-XRF and their potential applications. Spectrum evaluation, a key step in X-ray spectrometry, is covered in depth, including discussion on several calibration and peak fitting techniques and ...
1986-06-25
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...
1989-06-01
Phantom and animal imaging studies using PLS synchrotron X-rays
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...
2001-01-01
Noninvasive analysis of skin iron and zinc levels in beta-thalassemia major and intermedia
Energy Technology Data Exchange (ETDEWEB)
Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive ...
1985-01-01
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...
2009-12-01
International Nuclear Information System (INIS)
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...
2009-12-01
Hyaluronic acid production by irradiated human synovial fibroblasts
International Nuclear Information System (INIS)
Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced by the x-ray machine was inhibited by ...
1977-01-01
Broad-band stigmatic spectrograph for the soft x-ray range
International Nuclear Information System (INIS)
We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)
1998-09-30
The duke XUV FEL storage ring facility
Energy Technology Data Exchange (ETDEWEB)
In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)
1998-11-01
The Linac Cooherent Light Source (LCLS) Accelerator
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.
2007-03-21
International Nuclear Information System (INIS)
The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.
2006-01-01
Linac Coherent Light Source Longitudinal Feedback Model
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.
2005-06-15
Energy Technology Data Exchange (ETDEWEB)
With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.
1996-04-01
International Nuclear Information System (INIS)
Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.
2006-09-25
Energy Technology Data Exchange (ETDEWEB)
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
1995-02-01
International Nuclear Information System (INIS)
The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).
1986-01-01
Simulations of the Microwave Sky
Energy Technology Data Exchange (ETDEWEB)
We create realistic, full-sky, half-arcminute resolution simulations of the microwave sky matched to the most recent astrophysical observations. The primary purpose of these simulations is to test the data reduction pipeline for the Atacama Cosmology Telescope (ACT) experiment; however, we have widened the frequency coverage beyond the ACT bands and utilized the easily accessible HEALPix map format to make these simulations applicable to other current and near future microwave background experiments. Some of the novel features of these simulations are that the radio and infrared galaxy populations are correlated with the galaxy cluster and group populations, the primordial microwave background is lensed by the dark matter structure in the simulation via a ray-tracing code, the contribution to the thermal and kinetic Sunyaev-Zel'dovich (SZ) signals from galaxy clusters, groups, and the intergalactic medium has been included, and the gas prescription to ...
2009-12-16
Upper Limits from HESS Observations of AGN in 2005-2007
Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.
2007-01-01
The temporal evolution of coronal loops observed by GOES-SXI
We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional ...
2006-01-01
Studies on the diagnostic accuracy of lymphography
International Nuclear Information System (INIS)
Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is ...
Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the ...
2008-01-01
X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope
International Nuclear Information System (INIS)
A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer of Al and metastable ...
1997-04-04
X-radiation effects on muscle cell membrane electrical parameters
International Nuclear Information System (INIS)
Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were ...
The ternary system cerium-palladium-silicon
British Library Electronic Table of Contents (United Kingdom)
Phase relations in the ternary system Ce-Pd-Si have been established for the isothermal section at 800degreeC based on X-ray powder diffraction and EMPA techniques on about 130 alloys, which were prepared by arc-melting under argon or powder reaction sintering. Eighteen ternary compounds have been observed to participate in the phase equilibria at 800degreeC. Atom order was determined by direct methods from X-ray single-crystal counter data for the crystal structures of t8-Ce3Pd4Si4 (U3Ni4Si4-type, Immm; a=0.41618(1), b=0.42640(1), c=2.45744(7)nm), t16-Ce2Pd14Si (own structure type, P4/nmm; a=0.88832(2), c=0.69600(2)nm) and also for t18-CePd1-xSix (x=0.07; FeB-type, Pnma; a=0.74422(5), b=0.45548(3), c=0.58569(4)nm). Rietveld refinements established the atom arrangement in the structures of...
2009-01-01
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...
2011-05-05
Structural, electronic and magnetic properties of splat-quenched FeCsub(x) alloys (x<0.05)
International Nuclear Information System (INIS)
The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity ...
2006-01-01
Soft X-ray holography of FIB nanostructured Co/Pt multilayers
International Nuclear Information System (INIS)
Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...
2009-03-22
Energy Technology Data Exchange (ETDEWEB)
The X-ray spectra of {approx}200 AGN collected from Swift-BAT were analyzed to test the Unified Model for AGN. Specifically, the photon indices, high energy cutoffs, and reflection components of Sy1 and Sy2 were compared. Under the Unified Model, the photon indices and reflection components for Sy1 should be larger than Sy2 and the high energy cutoffs should be the same. Fitting a simple power law model to the sample spectra proved to be insufficient. The PEXRAV model fit the spectra of the Sy1 and Sy2 significantly better, indicating that a reflection component and/or high energy cutoff exists as the Unified Model expects. Using both the simple power law and PEXRAV models it was concluded that in the population studied, Sy1 had a larger photon index than Sy2, as expected by the Unified Model. For Sy1 and Sy2, the reflection components were found to be compatible, but given the large errors, this finding cannot be said to be evidence against the Unified Model. ...
2010-08-25
Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...
2008-01-01
K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma
Energy Technology Data Exchange (ETDEWEB)
K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.
1985-05-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise ...
1987-01-01
Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT
International Nuclear Information System (INIS)
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...
1986-01-01
Development of sialon using Yttria and alumina as additive
International Nuclear Information System (INIS)
Full text: The production of #beta#-sialon from kaolinite and carbon has been studied using Hulu Langat Kaolin and activated carbon as raw materials. The sintered temperature is shown to play a prominent role in the process of sialon conversion. Apart from temperature, nitrogen flow rate is also affect the production of #beta#--sialon. This study was carried out on the effect of additive, Y_2O_3 and Al_2O_3 at different temperature that will be mixed and sintered. The additives are expected to affect the formation of #beta#--sialon and Y-sialon upon the synthesis. The mineral and phase development was analysed using X-Ray Diffraction technique (Rigaku Geigerflex) while its chemical compositions through X-Ray Fluorescent Spectrophotometer (Shimadzu XRF 1700) and the particle size distribution analysis through Particle Size Analyser (Horiba, CAPA 700). The observed changes in the microstructure were analysed using the Hitachi ...
2005-08-16
Charge redistribution in ion-beam-mixed Pd-Ag alloys
Charge flow and valence/d-band behavior in ion-beam-mixed (IBM) Pd1-xAgx (x = 0.5-0.9) alloys have been studied by X-ray photoemission measurement of the valence bands and of core-level binding energy shifts and X-ray absorption near-edge structure. We correlated the observed Ag 3d5/2 core-level shifts in these IBM alloys, relative to the elemental Ag, with the White Line area changes at the Pd and Ag L3-edge to investigate the charge redistribution at the Ag site. The results indicate that there is a decrease in sp-like conduction electron and a negligible change in the number of d-electrons at the Ag site upon alloying. These results are in line with our previous results in which Pd gains d-charges and loses sp-type charges. This electron redistribution due to hybridization in the alloy leads small net charge transfer from the Ag site to the Pd site in accordance with electronegativity predictions. This result is ...
1996-08-01
International Nuclear Information System (INIS)
In this work we investigate an iron oxide thin film grown with atomic layer deposition for a gas sensor application. The objective is to characterize the structural, chemical, and electrical properties of the film, and to demonstrate its gas-sensitivity. The obtained scanning electron microscopy and atomic force microscopy results indicate that the film has a granular structure and that it has grown mainly on the glass substrate leaving the platinum electrodes uncovered. X-ray diffraction results show that iron oxide is in the #alpha#-Fe_2O_3 (hematite) phase. X-ray photoelectron spectra recorded at elevated temperature imply that the surface iron is mainly in the Fe"3"+ state and that oxygen has two chemical states: one corresponding to the lattice oxygen and the other to adsorbed oxygen species. Electric conductivity has an activation energy of 0.3-0.5 eV and almost Ohmic current-voltage dependency. When exposed to O_2 and CO, a typical ...
2008-07-31
Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser
International Nuclear Information System (INIS)
We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various ...
2008-04-01
Anisotropy in Magnetic Properties and Electronic Structure of Single Crystal LiFePO4
Energy Technology Data Exchange (ETDEWEB)
We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different feature assignment for ...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...
2010-01-01
Synthesis, crystal structure and photoluminescence of Eu-#alpha#-SiAlON
International Nuclear Information System (INIS)
Eu-#alpha#-SiAlON (Eu_m_/_2Si_1_2_-_m_-_nAl_m_+_nO_nN_1_6_-_n) was synthesized with nominal compositions having small m and n values, by firing the powder mixture of Eu_2Si_5N_8, #alpha#-Si_3N_4, AlN, and Al_2O_3 at 1900 "oC for 6 h under 1 MPa nitrogen atmosphere. The ratio of the oxidation state of Eu"2"+/Eu"3"+ was estimated from the X-ray absorption fine structure (XAFS) measurement. The observed X-ray absorption near edge spectrum (XANES) showed that the Eu ion in Eu-#alpha#-SiAlON was mainly in divalent state but also coexisted with a small amount of Eu in the trivalent state. The crystal structure of Eu-#alpha#-SiAlON was refined by the Rietveld analysis of the X-ray powder diffraction patterns. The lattice constants of the samples increased with increasing m and n values. The excitation band of Eu-#alpha#-SiAlON ranged from the ultraviolet to the visible light region and a broad emission band ...
2010-08-20
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide ...
Stabilization of synchrotron radiation x-ray beam by MOSTAB
International Nuclear Information System (INIS)
Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)
2003-05-01
Spin evolution in wind-fed X-ray binaries
International Nuclear Information System (INIS)
Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).
Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice
Examples are given of the applicability and importance of radionuclide fluorescence analysis as a
1973-01-01
Radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,
1973-01-01
Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging
International Nuclear Information System (INIS)
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...
... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...
International Nuclear Information System (INIS)
X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)
2001-09-23
... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...
Radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).
1994-01-01
Thermoluminescence studies in lead doped KCl and KBr crystals
International Nuclear Information System (INIS)
Lead is known to enter substitutionally in divalent state when doped in alkali halides. When irradiated at room temperature these lead centers (Pb"+"+) act as traps for electrons knocked off from the halogen ions and become Pb"+ and Pb"0 (for large doses of irradiation). These changes could be followed in the optical absorption studies. These lead-doped crystals after X-ray irradiation yield a thermoluminescence output smaller than that observed in 'pure' crystals. However, two new glow peaks are observed in additions to those due to F-centers. In KCl : Pb and Kbr : Pb crystals part of the F-center glow preceds the new glow peaks. The new peaks are attributed to the Pb"+ and Pb"0 centers. The glow peak temperatures and trap depths for these peaks an obtained by total-curve fitting method are reported. (author).
1975-02-12
Pd adsorption on Si(1 1 3) surface: STM and XPS study
Energy Technology Data Exchange (ETDEWEB)
Pd-induced surface structures on Si(1 1 3) have been studied by scanning tunneling microscopy (STM) and X-ray photoelectron spectroscopy (XPS). In the initial process of the Pd adsorption below 0.10 ML, Pd silicide (Pd{sub 2}Si) clusters are observed to form randomly on the surface. By increasing the Pd coverage to 0.10 ML, the clusters cover the entire surface, and an amorphous layer is formed. After annealing the Si(1 1 3)-Pd surface at 600 deg. C, various types of islands and chain protrusions appears. The agglomeration, coalescence and crystallization of these islands are observed by using high temperature (HT-) STM. It is also found by XPS that the islands correspond to Pd{sub 2}Si structure. On the basis of these results, evolution of Pd-induced structures at high temperatures is in detail discussed.
2008-09-30
Microstructure and mechanical properties of magnesium alloy AZ31B laser beam welds
International Nuclear Information System (INIS)
Microstructure and properties of a Mg AZ31B laser beam weld without filler are studied using electron microscopy, X-ray diffraction and mechanical tests. The microstructure of the weld is characterized by a narrow heat affected zone, columnar grains and precipitate coarsening in the fusion zone. Texture in the fusion zone is significantly different from the texture of the base material. The residual stress distribution observed is similar at the top and the bottom of the weld, maximum tensile residual stress values are observed in the fusion zone. Tensile tests reveal differences in the mechanical behavior of the fusion zone and the parent material, which can be related to the differences of texture and the resulting deformation mechanisms.
2008-06-25
Influence of annealing on the microstructure of commercial Mg alloy AZ31 after mechanical forming
International Nuclear Information System (INIS)
The microstructure of commercial rolled magnesium alloy AZ31B (nominal composition Mg-3Al-0.9Zn-0.15Mn in wt.%) was investigated with the help of light microscopy, electron backscatter diffraction (EBSD) and X-ray diffraction technique after annealing in the temperature range from room temperature (RT) to 400 deg. C. Tensile tests at RT were performed to show the influence of the microstructure on mechanical properties. Static recrystallization (SRX) was observed during annealing of as-received alloy at and above 150 deg. C. Twins play an important role during SRX and serve as nucleation sites and preferred paths for growth of grains. The strong basal texture caused by rolling was weakened by SRX. Significant differences in the stress strain curves were observed for as-received and annealed specimens.
2006-09-25
Energy Technology Data Exchange (ETDEWEB)
Nanosized CaSnO{sub 3} is synthesized by a hydrothermal process and characterized by X-ray diffraction (XRD), Raman spectroscopy, and scanning electron microscopy (SEM). The SEM observation shows the sample has a porous flowerlike morphology. The electrochemical results exhibit that the stable and reversible capacity of 547 mAh g{sup -1} is obtained after 50 cycles at 60 mA g{sup -1} (0.1 C) and the corresponding charge capacity is determined to be 316 mAh g{sup -1} at the current density of 2.5 C. Cyclic voltammetry and electrochemical impedance spectroscopy data are analyzed to complement the galvanostatic results. The observed excellent performance is attributed to the porous structure and large surface area of flowerlike CaSnO{sub 3}.
2010-04-30
Energy Technology Data Exchange (ETDEWEB)
The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.
1990-04-15
The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.
1990-04-15
A micro-alloyed ferritic steel strengthened by nanoscale precipitates
British Library Electronic Table of Contents (United Kingdom)
A ferritic steel with finely dispersed precipitates was investigated to reveal the fundamental strengthening mechanisms. The steel has a yield strength of 760MPa, approximately three times higher than that of conventional Ti-bearing high strength hot-rolled sheet steels, and its ultimate tensile strength reaches 850MPa with an elongation-to-failure value of 18%. Using energy dispersive X-ray spectroscopy (EDXS) and transmission electron microscope (TEM), fine carbides TiC with an average diameter of 10nm were observed in the ferrite matrix of the 0.08%Ti steel, and some cubic M23C6 precipitates were also observed at the grain boundaries and the interior of the grains. The finely dispersed TiC precipitates in the matrix provide matrix strengthening. The estimated magnitude of precipitation ...
2011-01-01
DNA cleavage on photoexposure at the d-d band in ternary copper(II) complexes using red-light laser.
Ternary copper(II) complexes [Cu(L1)B](ClO4) (1, 2) and [Cu(L2)B](ClO4) (3, 4), where HL1 and HL2 are tridentate NSO- and ONO-donor Schiff bases and B is a heterocyclic base, viz. dipyrido[3,2-d:2',3'-f]quinoxaline (dpq, 1 and 3) or dipyrido[3,2-a:2',3'-c]phenazine (dppz, 2 and 4), were prepared and their DNA binding and photoinduced DNA cleavage activity studied. Complex 1, structurally characterized by single-crystal X-ray crystallography, shows an axially elongated square-pyramidal (4 + 1) coordination geometry in which the monoanionic L1 binds at the equatorial plane. The NN-donor dpq ligand exhibits an axial-equatorial binding mode. The complexes display good binding propensity to calf thymus DNA, giving a relative order 2 (NSO-dppz) > 4 (ONO-dppz) > 1 (NSO-dpq) > 3 (ONO-dpq). They cleave supercoiled pUC19 DNA to its nicked circular form when treated with 3-mercaptopropionic acid (MPA) by formation of hydroxyl radicals as the cleavage active species ...
2006-12-25
Energy Technology Data Exchange (ETDEWEB)
Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV ...
2001-05-16
Energy Technology Data Exchange (ETDEWEB)
Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were analysed. In order to detect trans-generational genomic instability, a total of 4806 metaphases from foetal ...
2008-04-02
International Nuclear Information System (INIS)
We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au"2"+ ion at fluence values of 1x10"1"3, 5x10"1"3, and 1x10"1"4/cm"2. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the x rays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the shapes of resultant strain profiles, we ...
2009-08-15
Energy Technology Data Exchange (ETDEWEB)
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...
1995-07-20
International Nuclear Information System (INIS)
The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in cerebral cortex (CX) of ID ...
2004-02-27
Energy Technology Data Exchange (ETDEWEB)
Glasses in the system (1 - x) [29Na{sub 2}O- 4Al{sub 2}O{sub 3}- 67B{sub 2}O{sub 3}]- xZnO (0 {<=} x {<=} 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N{sub 4} values (fraction of tetrahedral coordinated boron atoms), and ...
2009-05-05
ESR study of X-ray irradiated rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite
Energy Technology Data Exchange (ETDEWEB)
X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K{sub 3}Na(SO{sub 4}){sub 2}) matrix or the langbeinite (K{sub 2}Mg{sub 2}(SO{sub 4}){sub 3}) matrix were synthesized by heating the mixture of K{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} or the mixture of K{sub 2}SO{sub 4} and MgSO{sub 4} at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln{sub 2}(SO{sub 4}){sub 3} (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K{sub 2}SO{sub 4}, Na{sub 2}SO{sub 4} and Ln{sub 2}(SO{sub 4}){sub 3} powders or a fixed amount of K{sub 2}SO{sub 4}, MgSO{sub 4} and Ln{sub 2}(S0{sub 4}){sub ...
1992-06-01
Energy Technology Data Exchange (ETDEWEB)
Y{sub 2-x}Tb{sub x}SiO{sub 5} and Y{sub 2-x}Eu{sub x}SiO{sub 5} nanophosphors with seven different kinds of silicate sources were synthesized by sol-gel method. The structures have been investigated to be composed of nanometer-size grains of 30-60 nm through X-ray diffraction (XRD) and scanning electron microscopy (SEM) was used to compare the different morphology of patterns from seven different silicon sources. The photoluminescence of Y{sub 2-x}Tb{sub x}SiO{sub 5} was investigated as a function of silicate sources and the results revealed that these nanometer materials showed the characteristic emission {sup 5}D{sub 4} {yields} {sup 7}F{sub J} (J 6, 5, 4, 3) of Tb ions. The characteristic emission {sup 5}D{sub 0} {yields} {sup 7}F{sub J} (J = 1, 2, 4) of Eu ions was also found in the materials of Y{sub 2-x}Eu{sub x}SiO{sub 5}.
2008-01-15
Computational AstroStatistics Fast and Efficient Tools for Analysing Huge Astronomical Data Sources
I present here a review of past and present multi-disciplinary research of the Pittsburgh Computational AstroStatistics (PiCA) group. This group is dedicated to developing fast and efficient statistical algorithms for analysing huge astronomical data sources. I begin with a short review of multi-resolutional kd-trees which are the building blocks for many of our algorithms. For example, quick range queries and fast n-point correlation functions. I will present new results from the use of Mixture Models (Connolly et al. 2000) in density estimation of multi-color data from the Sloan Digital Sky Survey (SDSS). Specifically, the selection of quasars and the automated identification of X-ray sources. I will also present a brief overview of the False Discovery Rate (FDR) procedure (Miller et al. 2001a) and show how it has been used in the detection of ``Baryon Wiggles'' in the local galaxy power spectrum and ...
2001-01-01
Validity of the CT to attenuation coefficient map conversion methods
International Nuclear Information System (INIS)
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
2004-04-27
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Radiation from Relativistic Strongly Magnetized Outflows
Relativistic strongly magnetized winds outflowing from fast-rotating compact objects like millisecond pulsars with surface magnetic fields of $\\sim 10^{15}-10^{16}$ G are plausible sources of cosmological $\\gamma$-ray bursts. In such winds, there are at least three regions where extremely powerful X-ray and $\\gamma$-ray emission may be generated. The first radiating region is the wind photosphere that is at a distance of $\\sim 10^9$ cm from the compact object. The second radiating region is at a distance of $\\sim 10^{13}-10^{14}$ cm. In this region, the striped component of the wind field is transformed into large-amplitude electromagnetic waves. The third radiating region is at a distance of $\\sim 10^{16}-10^{17}$ cm, where deceleration of the wind due to its interaction with an ambient medium becomes important. Radiation from all these regions is considered.
1999-01-01
International Nuclear Information System (INIS)
The structure of nano-porous carbon, obtained by means of chlorination of carbide compounds with various crystal structure (SiC, TiC, Mo_2C) is studied through the method of small-angle diffraction. The angular dependences of the scattering intensity obtained are interpreted as the result of scattering from the nanoparticles of different size. The functions of the scattering particles distribution by the m(R_g) inertia radii are determined. It is shown that in spite of the source carbide, the highest fraction of the volume in the porous carbon constitute the particles with R_g #approx# 5 A. The nanoparticles in the samples obtained from SiC, wherein the average value of the R_g"a"v < 6 A, are most uniform by size. The nanoparticles in the porous carbon, obtained from Mo_2C, are on the average by two times larger
1999-08-01
Investigation of lattice strains in layered structures containing porous silicon
International Nuclear Information System (INIS)
Silicon layered structures containing porous silicon modified with various thermal treatments and epitaxial layers deposited on porous layers were studied with a number of complementary X-ray diffraction methods using synchrotron source. The methods of characterization included recording of rocking curves for reflections with various asymmetry as well as projection, section and micro-Laue topography. It was found that oxidizing and sintering of porous silicon seriously modified the strains in the porous layer and in some cases even inverting the sense of strain with respect to that in initially formed porous layer. Consequently the deposited epitaxial layer usually was not laterally coherent with the substrate. Some of investigated layers were not stable in time and after few months period exhibited significant lost of coherence of porous skeleton. (author)
2001-09-23
Identification of fatigue damage in cortical bone by diffraction enhanced imaging
International Nuclear Information System (INIS)
In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.
2005-08-11
International Nuclear Information System (INIS)
Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.
2010-09-01
Elemental analysis of savannah grass' burning ashes
International Nuclear Information System (INIS)
In order to quantify the biomass burning emissions, the main atmospheric pollution source of tropical and subtropical regions, we carried out the analysis of ashes that are also formed during these fires. To this end, we developed analytical methods to characterize the composition of savannah grass burning ashes by using X-ray fluorescence for mineral elements and microanalysis for C, H, O and N. Samples used in this work have been collected during laboratory combustion experiments, with chemically well-defined natural savannah grasses from Ivory Coasts and South Africa. The reproducibility and efficiency of different developed procedures have been studies. The analytical relative precision is generally better than 5%. This development has allowed to establish, for the first time, the global mass balance of ashes resulting from savannah grass burning. (authors). 16 refs., 3 figs., 8 tabs.
Diffusion examined by diffraction
X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
2006-01-15
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation
International Nuclear Information System (INIS)
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
International Nuclear Information System (INIS)
The sampling is described for radionuclide X-ray fluorescence analysis. Aerosols are captured with various filter materials whose properties are summed up in the table. Fine dispersed solid and liquid particles and gaseous admixtures may be captured by bubbling air through a suitable absorption solution. The concentration of small amounts of impurities from large volumes of air is done by adsorbing impurities on surfactants, e.g., activated charcoal, silica gel, etc. Aerosols may be captured using an electrostatic precipitator and aerosol fractions may be separated with a cascade impactor. Water sampling differs by the water source, i.e., ground water, surface water, rain or waste water. Soil samples are taken by probes. (ES).
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...
2005-06-11
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...
1988-01-01
Broad-band hard X-ray reflectors
DEFF Research Database (Denmark)
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
1997-01-01
A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland
Energy Technology Data Exchange (ETDEWEB)
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
1995-12-31
Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility
Energy Technology Data Exchange (ETDEWEB)
NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including ...
2007-05-07
DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology
International Nuclear Information System (INIS)
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...
2006-11-13
[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
1986-01-01
Transmission electron microscopy study of plasma nitriding of electroplated chromium coating
Energy Technology Data Exchange (ETDEWEB)
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 {mu}m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...
2003-02-28
Transmission electron microscopy study of plasma nitriding of electroplated chromium coating
International Nuclear Information System (INIS)
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 #mu#m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...
2003-02-28
Transformation kinetics and microstructures of Ti17 titanium alloy during continuous cooling
International Nuclear Information System (INIS)
We have investigated the microstructure evolutions in the Ti17 near #beta# titanium alloy during heat treatments. The phase transformation has first been studied experimentally by combining X-ray diffraction analysis, electrical resistivity and microscopy observations. From a series of isothermal treatments, a IT diagram has been determined, which takes into account the different morphologies. Then, a Johnson-Mehl-Avrami-Kolmogorov (JMAK) model has been successfully used to describe the phase transformation kinetics during either isothermal or cooling treatments. Finally, the coupling of the JMAK model to the finite element software ZeBuLoN allowed us to investigate the evolution of the spatial distribution of the different morphologies during the cooling of an aircraft engine shaft disk after forging.
2007-03-15
British Library Electronic Table of Contents (United Kingdom)
Nylon copolymer (PA6, 66) and ethylene propylene diene (EPDM) blends with and without compatibilizer were prepared by melt mixing using Brabender Plasticorder. The thermal stability of nylon copolymer (PA6, 66)/ethylene propylene diene rubber (EPDM) blends was studied using thermogravimetric analysis (TGA). The morphology of the blends was investigated using scanning electron microscopy (SEM). In this work, the effects of blend ratio and compatibilisation on thermal stability and crystallinity were investigated. The incorporation of EPDM rubber was found to improve the thermal stability of nylon copolymer. The kinetic parameters of the degradation process were also studied. A good correlation was observed between the thermal properties and phase morphology of the blends. By applying Coats ...
2008-01-01
The unusual host galaxy of the BL Lac object PKS 1413+135
The BL Lacertae object PKS 1413+135 is associated with a disk dominated galaxy which heavily absorbs the BL Lac nucleus at optical and X-ray wavelengths. It has been argued whether this galaxy is actually the host galaxy of PKS 1413+135 or whether the BL Lac is a background QSO, gravitationally lensed by the apparent host galaxy. We have obtained deep high resolution H-band images of this unusual BL Lac object using the UKIRT IRCAM3. Our observations show that the BL Lac nucleus is centered within < 0.05 arcsec of the galaxy. Based on this result we assess the probability for the lensing scenario and come to the conclusion that the disk galaxy is indeed the host of PKS 1413+135. The galaxy shows peanut-shaped isophotes, suggesting the presence of a central bar which is a common feature of AGN
1999-01-01
The elevation of blood levels of zinc protoporphyrin in mice following whole body irradiation
Energy Technology Data Exchange (ETDEWEB)
Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system from radiation injury.
1984-05-01
International Nuclear Information System (INIS)
A new in vivo method has been developed for the precise observation of RES activity. Both Escherichia coli endotoxin 100 #mu#g/100 g i.v. (LPS) and radiodetoxified endotoxin 100 #mu#g/100 g body weight i.v. (RD-LPS, TOLERIN) increased the granulopectic activity of RES. The RD-LPS was more effective. The preparation containing trace elements also increased the activity of RES. The treatment consisting of the use of both trace elements and RD-LPS proved to be the most effective. The activity of RES was inversely proportional to various doses of X-ray irradiation (7, 8, 9 Gy). Trace elements and RD-LPS even improved the immunity system of animals having deteriorated RES. (N.T.).
The deformation behavior of DyCu ductile intermetallic compound under compression
British Library Electronic Table of Contents (United Kingdom)
In this study polycrystalline specimens of as-cast DyCu with B2 crystal structure were compressed to different strains at room temperature to test if stress-induced phase transformation and twinning occur during deformation. In these tests DyCu exhibited high ductility with plastic strain as high as 35% and ultimate compressive strength of ~790MPa. X-ray diffraction and transmission electron microscopy (TEM) showed no indications that DyCu had undergone stress-induced phase transformation or twinning. -type dislocations have been observed to play an important role for imparting the ductile behavior. TEM analyses showed the presence of second phases, Dy2O3 and DyCu2 within the DyCu. The mechanisms of ductility and impurity phase formation are discussed.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
LiNi{sub 0.8}Co{sub 0.2}O{sub 2} particles from high-power lithium-ion cells were examined to determine material changes that result from accelerated aging tests. X-ray absorption spectroscopy (XAS) and transmission electron microscope (TEM) data indicated a Li{sub x}Ni{sub 1-x}O-type layer on the particle surfaces. The greater thickness on particles from high-power fade cells indicate that these surface layers are a significant contributor to cathode impedance rise observed during cell tests.
2002-08-01
Simple chemical method for nanoporous network of In2S3 platelets for buffer layer in CIS solar cells
British Library Electronic Table of Contents (United Kingdom)
Indium sulfide thin films consisting of porous network of nanoplatelets, have been deposited using chemical bath deposition (CBD) method onto the tin-doped indium oxide (ITO) coated glass substrate. Aqueous solutions of indium sulfate and thioacetamide have been used as indium and sulfur precursors. As a complexing agent, acetic acid was used. The chemically deposited indium sulfide thin films were examined for their structural, surface morphological and optical characterizations. The X-ray diffraction analysis revealed the formation of the cubic b-In2S3 onto the substrate. From scanning electron micrograph, it is observed that the surface of substrate is covered by nanoporous platelets type morphology. The optical studies showed a direct band gap of 2.84eV for indium sulfide platelets. Ph...
2008-01-01
Real-time neutron scattering investigations of biological signal transduction dynamics
Energy Technology Data Exchange (ETDEWEB)
During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France.
2005-07-01
Real-time neutron scattering investigations of biological signal transduction dynamics
International Nuclear Information System (INIS)
During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France
2005-04-11
Plasma nitriding of microalloyed steel
Energy Technology Data Exchange (ETDEWEB)
Microalloyed or high strength low alloy (HSLA) steels are carbon-manganese steels containing small amounts of Nb, V or Ti. The excellent mechanical properties of these alloys, particularly high yield strength, usually obviate the need for expensive quench and tempering operations. Furthermore, the presence of a significant amount of nitride-forming elements in some microalloyed steels has generated interest in the applicability of these alloys as a new generation of nitriding steels. In this paper, a study of the plasma nitriding behaviour of a commercially available microalloyed steel MAXIMA{sup TM} is reported. A comparison is made with a traditional quenched and tempered nitriding steel (En19), plasma nitrided under similar conditions. Optical and scanning electron microscopy in conjunction with microhardness measurements and X-ray diffraction were utilized to characterize the nitrided surfaces. The observed differences in the thickness and ...
1995-03-01
Phase Behavior and Interactions of the Membrane-Protein Bacteriorhodopsin
Energy Technology Data Exchange (ETDEWEB)
We present a synchrotron x-ray diffraction study of melting in stacks of two-dimensional crystalline arrays of the membrane protein bacteriorhodopsin. Two distinct regimes have been found as a function of the intermembrane distance d . In the {open_quotes}coupled{close_quotes} regime for d{lt}250 {Angstrom} the temperature (T{sub m}) of the melting transition decreases with increasing d , demonstrating the effect of the repulsive membrane interactions on the intramembrane protein ordering. For d{gt}250 {Angstrom} a {open_quotes}decoupled{close_quotes} regime is found with higher T{sup *}{sub m} independent of d . Below T{sup *}{sub m} a solid-liquid-solid reentrant behavior is observed as d is increased. {copyright} {ital 1999} {ital The American Physical Society}
1999-04-01
Oxidation of aromatic alcohols on zeolite-encapsulated copper amino acid complexes
Energy Technology Data Exchange (ETDEWEB)
Copper complexes of the amino acids histidine, arginine and lysine have been introduced into the supercages of zeolite Y and, for the first time, into the large intracrystalline cavities of zeolites EMT and MCM-22. The resulting host/guest compounds are characterized by X-ray powder diffraction, UV/VIS-spectroscopy in the diffuse reflectance mode and by catalytic tests in the liquid-phase oxidation of aromatic alcohols (viz. benzyl alcohol, 2- and 3-methylbenzyl alcohol and 2,5-dimethylbenzyl alcohol) with tertiary-butylhydroperoxide as oxidant. It was observed that intracrystalline copper-amino acid complexes possess remarkable catalytic activity, yielding the corresponding aromatic aldehydes and acids. (orig.)
1998-12-31
Morphology evolution of Ir-Nb-X (X = Hf, Ta, or Ti) ternary alloys
Energy Technology Data Exchange (ETDEWEB)
The microstructure evolution of nine samples from three Ir-base ternary systems, Ir-Nb-Hf, Ir-Nb-Ta, and Ir-Nb-Ti, was investigated by microstructure observation using scanning electron microscopy (SEM), composition map-analysis using electron probe microscopy analysis (EPMA), and phase determination using X-ray diffraction (XRD) patterns. The fcc/L1{sub 2} two-phase structure was detected in all the samples. Lattice misfits between fcc and L1{sub 2} phases were calculated. Ir-Nb-Ta and Ir-Nb-Ti alloys exhibited a microstructure quite similar to that of Ni-base superalloys, and the cuboidal L1{sub 2} precipitates in Ir-Nb-Ta and Ir-Nb-Ti alloys could maintain up to 1900 {sup o}C.
2007-01-31
Microstructural characterization of plasma nitrided austenitic stainless steel
Energy Technology Data Exchange (ETDEWEB)
The microstructure of the layers produced by plasma nitriding austenitic stainless steel at different treatment temperatures (400 and 500 C) were studied by transmission electron microscopy (TEM) together with X-ray diffraction (XRD) and scanning electron microscopy (SEM). The results show that the microstructures were composed of 'expanded austenite' ({gamma}{sub N}) and {alpha}(ferrite)+CrN following plasma nitriding at lower and higher treatment temperatures, respectively. The former contains stacking faults and deformed twin substructures, while the latter is made up of colonies displaying a lamellar structure. Kurdjumov-Sachs or Nishiyama-Wassermann orientation relationships between the {alpha} and CrN layer were observed. (orig.)
2000-10-23
British Library Electronic Table of Contents (United Kingdom)
Laser welding of AISI 904 L super austenitic stainless steel using a diffusion cooled slab 3.5kW CO2 laser and employing two different shielding gases, namely argon and helium, was carried out. The laser weld bead profile depends on various parameters such as beam power (BP), travel speed (TS) and focal position (FP) of the laser spot. These parameters have to be selected suitably to obtain the desirable output. The cross sectioned area of the bead profiles measured using an optical microscope to determine the bead width and depth of penetration. X-ray diffraction used for phase identification confirmed that the weld structure was fully austenitic and dendritic. Hardness was observed to increase in the weld bead with respect to the parent metal and it was related to the microstructural ref...
2010-01-01
Ion beam induced damage and element loss during a microanalysis of biological tissue
Energy Technology Data Exchange (ETDEWEB)
Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).
1991-03-01
Identifying fade mechanisms in high-power lithium-ion cells.
Energy Technology Data Exchange (ETDEWEB)
Hybrid electric vehicles (HEV) need long-lived high-power batteries as energy storage devices. Batteries based on lithium-ion technology can meet the high-power goals but have been unable to meet HEV calendar-life requirements. As part of the US Department of Energy's Advanced Technology Development (ATD) Program, diagnostic studies are being conducted on 18650-type lithium-ion cells that were subjected to accelerated aging tests at temperatures ranging from 40 to 70 C. This article summarizes data obtained by gas chromatography, liquid chromatography, electron microscopy, X-ray spectroscopy and electrochemical techniques, and identifies cell components that are responsible for the observed impedance rise and power fade.
2004-01-01
High coercivity in Nd-Fe-Al-Co-B alloys prepared by mechanical milling
Energy Technology Data Exchange (ETDEWEB)
Nd{sub 40}Fe{sub 30}Al{sub 10}Co{sub 15}B{sub 5} alloys were fabricated by high energy ball milling method under various conditions. Microstructure of the alloys was investigated by X-ray diffraction and electron microscopy techniques. Magnetic properties were characterized by hysteresis and thermomagnetic measurements. The high coercive fields up to 2.36 T have been observed on the samples consisting of Nd{sub 2}(Fe,Co,Al){sub 14}B, Nd{sub 6}(Fe,Co,Al){sub 14} and Nd crystallites imbedded in a residual amorphous matrix.
2008-02-15
Formation of AlN-polytypoid phases during #alpha#-SiAlON decomposition
International Nuclear Information System (INIS)
Phase transformations from #alpha#- to #beta#-SiAlONs (i.e., from #alpha#' to #beta#') have been recently reported in a number of rare-earth SiAlON systems during postsintering heat treatment. In the present work, this transformation process in a Sm (#alpha# + #beta#)-SiAlON material is studied by using XRD, TEM, and EDS X-ray mapping techniques. It is observed that in addition to the formation of #beta#' and M' phases, the #alpha#'-to-#beta#' transformation is accompanied by a significant increase in the amount of an AlN-polytypoid phase. The results suggest that some #alpha#' phases are thermodynamically unstable at temperatures lower than the material sintering temperature and will decompose when conditions allow. For the composition studied in this work, the #alpha#-SiAlON decomposition can be described in general as #alpha#' #-># #beta#' + M' + AlN polytypoid.
Environmentally conscious sintered glass-ceramics
Energy Technology Data Exchange (ETDEWEB)
Sintered glass-ceramics have been produced using municipal incinerator solid residues and glass cullet or an inert waste, from feldspars processing, as sintering aids. The capability of three different mixtures, either previously vitrified or not, to be sintered was investigated by means of linear shrinkage, water absorption and bulk density measurements, and by X-ray diffraction analysis and scanning electron microscopy observations. Particular attention has been addressed to the study of particle size effect on the sintering process. The conclusions that can be drawn from the experimental study are that the preliminary vitrification step is essential in order to obtain a dense sintered glass-ceramic product in the 850-1050 C temperature range developing silicate crystalline phases. The optimal powder particle size that confers a good densification degree was found to be < 45 {mu}m. (orig.)
2002-07-01
Electrochemical deposition of indium sulfide thin films using two-step pulse biasing
British Library Electronic Table of Contents (United Kingdom)
Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
This study describes the effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane (silane coupling agent, Si69, TESPT) on in situ sodium activated, organo modified bentonite clay - styrene butadiene rubber (SBR) nanocomposite. transmission electron microscopy and Wide angle X-ray diffraction indicated the intercalation as well as partial exfoliation in both the organoclay and silane treated organoclay compound. It was found that about 5% of silane with respect to clay was the optimum dose for the treatment. Around 15% improvement in tensile and tear strength was observed due to silane treatment. Silane treated organoclay exhibited substantial improvement of the fatigue life, compression set, and rebound property. A detailed study of physical property was carried out. A comparison wi...
2010-01-01
International Nuclear Information System (INIS)
The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of investigations of TAT activity changes obtained in ...
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...
2011-01-01
Characterization of acid sites in pentasil zeolites by x-ray photolectron spectroscopy
Energy Technology Data Exchange (ETDEWEB)
The N{sub 1s} XPS band of pyridine chemisorbed on Al-ZSM-5 zeolite was found to be properly deconvoluted into three component peaks. In a previous contribution these three components were assigned to pyridine chemisorbed on two kinds of Bronsted acid sites and one Lewis acid site. This analysis is extended here to Fe-ZSM-5 and B-ZSM-5. Isomorphous substitution of Fe for Si or Al in the zeolite framework leads to a slight decrease in the binding energy of the N{sub 1s} Lewis component. In the case of B substitution a decrease in the binding energy of all three N{sub 1s} components is observed.
1990-11-01
Characterization of (In1−xAlx)2S3 thin films grown by co-evaporation
British Library Electronic Table of Contents (United Kingdom)
In this paper, it is shown that (In1?xAlx)2S3 thin films can be grown through the co-evaporation of elemental indium, aluminum and sulfur. It is nevertheless observed that the introduction of aluminum within the indium sulfide thin films hinders the crystallites size and even yields almost amorphous films when x is 0.2. The investigations of the optical properties of the films reveal that contrary to what could be expected, the band gap increase is low; the highest values measured do not exceed 2.2eV. However, as suggested by X-ray photoelectron spectroscopy measurements, such widening most probably affects the lower conduction band states.
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
The determination of residual stress (RS) in case-hardened steel gear truck synchronisers coated with thermal sprayed molybdenum was carried out using neutron and synchrotron X-ray diffraction. Two samples with different coating thicknesses (about 120 ?m and 1.4 mm) and different steel substrates (16MnCr5 and SAE4140, respectively) were investigated. Microanalysis revealed substantial porosity in both samples and some debonding was observed between the thin coating and the substrate. The bulk hardness of the SAE 4140 proved to be much higher than the 16MnCr5 and the surface case-hardening increased it by a further 20%. The full three-dimensional stress depth-profile was determined by neutron diffraction (ND) in both the coatings and the substrates, while synchrotron radiation allowed a dep...
2006-01-01
Bandgap properties of the indium sulfide thin-films grown by co-evaporation
British Library Electronic Table of Contents (United Kingdom)
In the present study the optical properties of co-evaporated indium sulfide thin films are investigated. Before being optically characterized, the composition as well as the crystalline properties of the film have been checked with the help of energy dispersive spectroscopy (EDX) and X-Ray diffraction (XRD) analyses. The optical absorption coefficient ? of this indium sulfide film has been deduced from reflectivity R(?) and transmission T(?) measurements. The fit of the curve representing ?(h?) suggests that the ?-In2S3 has an indirect bandgap of 2.01?eV. Density functional theory (DFT) calculations are performed on this indium sulfide compound, using TB-LMTO code. Through these band structure investigations, an indirect bandgap is predicted as observed experimentally. The top of the valen...
2009-01-01
Asymmetric Hydrogenation with Highly Active IndolPhos-Rh Catalysts: Kinetics and Reaction Mechanism
British Library Electronic Table of Contents (United Kingdom)
The mechanism of the IndolPhos-Rh-catalyzed asymmetric hydrogenation of prochiral olefins has been investigated by means of X-ray crystal structure determination, kinetic measurements, high-pressure NMR spectroscopy, and DFT calculations. The mechanistic study indicates that the reaction follows an unsaturate/dihydride mechanism according to Michaelis-Menten kinetics. A large value of KM (KM=5.01+-0.16 M) is obtained, which indicates that the Rh-solvate complex is the catalyst resting state, which has been observed by high-pressure NMR spectroscopy. DFT calculations on the substrate-catalyst complexes, which are undetectable by experimental means, suggest that the major substrate-catalyst complex leads to the product. Such a mechanism is in accordance with previous studies on the mechanism...
2010-01-01
A new method of determining the inclination angle in interacting binaries
We describe a method of determining the system parameters in non-eclipsing interacting binaries. We find that the extent to which an observer sees the shape of the Roche-lobe of the secondary star governs the amount of distortion of the absorption line profiles. The width and degree of asymmetry of the phase-resolved absorption line profiles show a characteristic shape, which depends primarily on the binary inclination and gravity darkening exponent. We show that, in principle, by obtaining high spectral and time resolution spectra of quiescent cataclysmic variables or low mass X-ray binaries in which the mass-losing star is visible, fitting the shape of absorption line profiles will allow one to determine not only the mass function of the binary, but also the binary inclination and hence the mass of the binary components.
1998-01-01
Anode length optimization in a modified plasma focus device for optimal x-ray yields
International Nuclear Information System (INIS)
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...
2006-01-01
Study of the mass of the electron neutrino in Japan
Energy Technology Data Exchange (ETDEWEB)
This report describes a study of the mass of the electron neutrino using electron capture in {sup 163}Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of {sup 163}Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very ...
1996-02-01
Mineralogical Data of Shocked Quartz Materials from K/T Boundary and Impact Crater
Shocked quartz minerals from the Cretaceous-Tertiary (K/T) boundary and impact craters have been mainly discussed from distribution of optical directions, mean optical refractive index, and X-ray data (1). The purpose of the present study is presentation of the detailed mineralogical data of shocked quartz found in the K/T boundaries and terrestrial impact craters (2,3,4,5). X-ray powder diffraction pattern of shocked quartz aggregate reveals that all Xray peaks are split into major three peaks composed of low-density quartz (LQ), normal quartz (Q), and shocked quartz with high density (SQ). X-ray peaks of (110), (200), (201), (202), and (211) in the hexagonal cell are also split into many peaks. The X-ray intensity among LQ, Q, and SQ phases indicates that the SQ phase shows 36% to 53% in six K/T boundary samples (5). The relative X-ray intensity ratio of shocked quartz to standard ...
1992-07-01
Energy Technology Data Exchange (ETDEWEB)
ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation is markedly reduced when irradiated annexin ...
2009-07-13
RF plasma nitriding of severely deformed iron-based alloys
International Nuclear Information System (INIS)
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher ...
2003-05-15
Direct observation of ordered orbital of YTiO{sub 3} by the X-ray magnetic diffraction technique
Energy Technology Data Exchange (ETDEWEB)
X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO{sub 3} for the first time. The orbital-magnetic form factor {mu} {sub L}(k) and the spin-magnetic form factor {mu} {sub S}(k) were independently measured by utilizing the LS separation ability of the XMD. The {mu} {sub L}(k) was measured for ten reciprocal-lattice points. No significant values of the {mu} {sub L}(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The {mu} {sub S}(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the {mu} {sub S}(k) gave the spin density distribution m {sub S}(r) in the real space. The obtained m {sub S}(r) map shows the characteristic feature of the electron distribution of 3d electron in the t{sub 2g} state of a Ti atom coordinated by O{sup 2-} ions, in which the electrons are ...
2005-08-15
Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge
Energy Technology Data Exchange (ETDEWEB)
Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, ...
2008-05-22
X-Ray Phase Imaging for Breast Cancer Detection
... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...
2010-09-01
UK PubMed Central (United Kingdom)
PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available
2008-03-01
Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.
UK PubMed Central (United Kingdom)
Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available
1995-09-12
UK PubMed Central (United Kingdom)
The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available
2008-04-11
Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid
Energy Technology Data Exchange (ETDEWEB)
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.
1982-02-18
Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid
International Nuclear Information System (INIS)
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).
1982-02-01
Radiation exposure due to X-rays of the hip joint in babies
International Nuclear Information System (INIS)
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
PIXE analysis of GaAs and ZnSe
Energy Technology Data Exchange (ETDEWEB)
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...
1990-01-01
PIXE analysis of GaAs and ZnSe
International Nuclear Information System (INIS)
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...
1989-06-01
Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers
UK PubMed Central (United Kingdom)
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
2011-03-01
UK PubMed Central (United Kingdom)
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
2008-01-01
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
UK PubMed Central (United Kingdom)
In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available
2009-01-01
Magnetic fields of x-ray pulsars
Energy Technology Data Exchange (ETDEWEB)
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
1982-09-01
Experimental X-ray intensity ratio L#beta#/L#alpha#
International Nuclear Information System (INIS)
Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).
1980-01-01
Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma
International Nuclear Information System (INIS)
A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
1986-04-01
Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...
SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...
Chemical effects on K x-ray intensity ratios in chromium compounds
International Nuclear Information System (INIS)
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
2003-02-10
Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides
International Nuclear Information System (INIS)
Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).
APOD: 2002 July 11 - M51: X Rays from the Whirlpool
picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...
2011-10-07
A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval
UK PubMed Central (United Kingdom)
Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available
2009-08-15
8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology
International Nuclear Information System (INIS)
Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).
1983-12-01
Superconducting properties of metallic superlattices
Energy Technology Data Exchange (ETDEWEB)
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
1987-01-01
Radionuclide X-ray fluorescence analysis using semiconductor detectors
International Nuclear Information System (INIS)
Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav
1979-05-01
Radionuclide X-ray fluorescence analysis of metal and amorphous materials
International Nuclear Information System (INIS)
Slovak May 1981. p. 30. Czechoslovakia Sandrik, R. Kliment, V.
1981-05-01
Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)
International Nuclear Information System (INIS)
... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,
2006-09-11
Microcomputers in radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske
1986-04-01
Experimental study of X-ray vidicon
International Nuclear Information System (INIS)
(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.
Electron-induced luminescence and x-ray spectrometer development: progress report
The progress in the development of a surface analysis tool based on the excitation of characteristic
2003-01-01
Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection
The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic
2002-01-01
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds
Energy Technology Data Exchange (ETDEWEB)
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
1990-12-20
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds
International Nuclear Information System (INIS)
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
1990-12-01
The evolution of x-ray binaries
International Nuclear Information System (INIS)
These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.
1993-10-11
Present state of radionuclide X-ray fluorescence analysis in coal mining
International Nuclear Information System (INIS)
Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).
1990-01-01
Pd-Na/F double exploding foil photoionization experiment
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
1990-03-01
Genetic and somatic risks in X-ray diagnosis
International Nuclear Information System (INIS)
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
1993-12-01
International Nuclear Information System (INIS)
The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.
1993-01-01
Synchrotron resource of the Howard Hughes Medical Institute
Energy Technology Data Exchange (ETDEWEB)
The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white ...
1989-07-01
Study of metal concentration in sediment of some springs of Lebanon
International Nuclear Information System (INIS)
Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr: 1999-11-02
Ozone production at the National Synchrotron Light Source
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and possible control ...
1998-09-20
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.
2011-06-22
Alternate Tunings for the Linac Coherent Light Source Photoinjector
Energy Technology Data Exchange (ETDEWEB)
The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the 1 ...
2006-03-17
Thermal annealing effect on optical properties of electrodeposited ZnO thin films
Energy Technology Data Exchange (ETDEWEB)
ZnO thin films were electrodeposited in aqueous solution on gilded p-type Si wafer substrates. Thermal treatments were carried out on different films in Ar atmosphere at different temperatures, between 200 and 600 {sup 0}C. Surface morphology studies using scanning electron microscopy and atomic force microscopy show a smooth surface for an annealing temperature of 400 {sup 0}C with a roughness mean square value of about 15 nm and a precipitation of ZnO microcrystals on the deposit surface at 600 {sup 0}C. X-ray diffraction experiments reveal a decrease in the c-parameter value from 5.223 to 5.206 A after treatment at 600 {sup 0}C, due to the removal of hydrogen from the film. Raman spectroscopy analyses show an improvement in the crystal quality of the film and a decrease in the compressive stress inside the deposit. Photoluminescence observations reveal an important change in the UV emission band after annealing at 200 {sup 0}C. A visible ...
2008-10-07
Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 Gy. Lymphocytes were scored using analysis of metaphase, for the ...
2003-01-01
Large perpendicular magnetic anisotropy of ultrathin Ru and Rh films on a NiAl(001) surface
International Nuclear Information System (INIS)
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is achieved in Rh film. Very interestingly, we find that both Ru/NiAl(001) and Rh/NiAl(001) ...
2010-10-27
International Nuclear Information System (INIS)
Thermo-reactive diffusion chromizing followed by pulsed plasma nitriding were carried out on AISI 52100 and 8620 bearing steels. The chromized samples were pulse-plasma nitrided for 5 h at 500 deg. C in various N_2-H_2 gas mixtures. The coated steels were characterized using scanning electron microscopy, X-ray diffraction and microhardness testing. The unlubricated wear behaviors of only chromized and duplex treated steels were investigated in ball-on-disc system tests at room temperature. X-ray diffraction patterns of the duplex treated samples containing H_2 indicated the formation of dominant CrN and Cr_2N nitrides as well as the formation of Cr_3C_2 and Cr_7C_3 carbides. Gas mixtures in the plasma nitriding, which was performed after chromizing, have a significant influence on the wear rate of the duplex treated steels. The wear and friction tests showed that the lowest friction coefficient and wear rates were observed ...
2008-12-01
Strain enhanced electron spin polarization observed in photoemission from InGaAs
International Nuclear Information System (INIS)
Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements represent the first observation of ...
1991-05-06
Neutron irradiation of superconducting compounds
International Nuclear Information System (INIS)
The effects of neutron irradiation on the superconducting and normal state properties of alloys and compounds are presented. Particular emphasis is placed on the A-15 compounds where the effects of neutron irradiation on Tsub(c), Hsub(c_2), long range order parameter and lattice parameter are described. Large depressions (up to 80%) in Tsub(c) are observed for all the A-15 compounds studied with the exception of Mo_3Os where much smaller decreases in Tsub(c) are seen. Along with the decrease in Tsub(c) and increase in lattice parameter, the degree of long range order, as measured by X-ray and neutron diffraction, decreases. Also presented are the results of isothermal and isochronal anneals up to 900"0C. The unirradiated value of Tsub(c) can be restored by annealing, and for those systems where measurements have been made, recovery of the lattice parameter and order parameter also takes place. The effects observed in ...
Latest Observational Constraints on Cardassian Models
Constraints on the original Cardassian model and the modified polytropic Cardassian model are examined from the latest derived 397 Type Ia supernova (SNe Ia) data, the size of baryonic acoustic oscillation peak from the Sloan Digital Sky Survey (SDSS), the position of first acoustic peak of the Cosmic Microwave Background radiation (CMB) from the five years Wilkinson Microwave Anisotropy Probe (WMAP), the x-ray gas mass fractions in clusters of galaxies, and the observational H(z) data. In the original Cardassian model with these combined data set, we find $\\Omega_{m0}=0.271^{+0.014}_{-0.014}, n=0.035^{+0.049}_{-0.049}$ at $1 \\sigma$ confidence level. And in the modified polytropic Cardassian model, we find that $\\Omega_{m0}=0.271^{+0.014}_{-0.015}$, $n=-0.091^{+0.331}_{-1.908}$ and $\\beta=0.824^{+0.750}_{-0.622}$ within $1\\sigma$ confidence level. According to these observations, the acceleration of the universe ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Transient enhanced diffusion of phosphorus in silicon has been investigated for implants below and above the threshold for a complete amorphization. Rapid thermal processes (electron beam) and conventional furnaces have been used for the annealing. In the case of implants below amorphization, a strong enhanced diffusion, proportional to the amount of damage produced, has been observed. The extent of the phenomenon is practically independent of the damage depth position. In contrast to this, the formation of extended defects at the original amorphous-crystalline interface makes the diffusivity strongly dependent on depth in the case of post-amorphized samples. No enhanced diffusion effect is observed if the dopant is confined in the amorphous layer, while a remarkable increase in the diffusivity is detected for the dopant located in the crystalline region beyond the amorphous-crystalline interface. Damage distribution after implantation and its ...
1989-03-01
Multi-Phase Fracture-Matrix Interactions Under Stress Changes
Energy Technology Data Exchange (ETDEWEB)
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several ...
2005-12-07
International Nuclear Information System (INIS)
HT-29 human colon tumor cells growing as spheroids have been evaluated as a model system for measuring the response of human colon tumor cell to antineoplastic agents. HT-29 cells have been capacity to form spheroids up to 1 mm or more in diameter when grown in spinner culture. The multicellular HT-29 spheroids develop hypoxic centers reflecting the cellular conditions found in human cancer treatment, i.e., nutritionally deficient hypoxic cells that are felt to be a significant source of both radiation and chemotherapy clinical treatment failures. Spheroids of increasing size were radiated and then dispersed into single cells for colony survival assay. Compared with irradiated single cell suspensions, the spheroid cells demonstrated a significant increase in radioresistance. Growing spheroids developed a complex radiation survival curve which was variable with respect to size of the spheroid. The drug 5-Fu was studied to examine in a preliminary fashion its ...
Pressure and impulse scaling methods for wall impact in ICF (inertial confinement fusion)
Energy Technology Data Exchange (ETDEWEB)
The design of the first structural wall (FSW) in an inertial confinement fusion (ICF) reactor requires some knowledge of the expected wall loading produced by x-ray and neutron deposition; specifically in the High Yield Lithium Injection Fusion Energy (HYLIFE) reactor, wall loading results from two sources -- gas shock and liquid impact. Gas shock is derived from x-ray deposition in the thin layers of exposed blanket material, producing ionized vapor, which will generate gas shock on the FSW. Liquid impact, on the other hand, results from the acceleration of liquid blanket material by two possible forces -- the drag from vapor expansion through the blanket material and the neutron-induced isochoric disassembly process. Both impacts, however, are coupled by the interaction of hot gas expanding through the liquid blanket. This paper discusses scaling methods for estimating pressure and impulse on the HYLIFE FSW from these ...
1990-01-01
Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique
An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, C, and F were detected at the Pd/sub ...
1986-05-15
Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser
Energy Technology Data Exchange (ETDEWEB)
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
2006-02-17
X-ray and UV-light irradiation effects on oxide superconducting thin films
International Nuclear Information System (INIS)
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...
Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo
Energy Technology Data Exchange (ETDEWEB)
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...
1998-10-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
