WorldWideScience
1

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application ...

2001-09-23

2

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

4

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

5

Study of the cyclotron feature in MXB 0656-072  

CERN Document Server

We have monitored a Type II outburst of the Be/X-ray binary MXB 0656-072 in a series of pointed RXTE observations during October through December 2003. The source spectrum shows a cyclotron resonance scattering feature at 32.8 +/- 0.5 keV, corresponding to a magnetic field strength of (3.67 +/- 0.06) x 10^12 G and is stable through the outburst and over the pulsar spin phase. The pulsar, with an average pulse period of 160.4 +/- 0.4 s, shows a spin-up of 0.45 s over the duration of the outburst. From optical data, the source distance is estimated to be 3.9 +/- 0.1 kpc and this is used to estimate the X-ray luminosity and a theoretical prediction of the pulsar spin-up during the outburst.

2006-01-01

6

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

7

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

8

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

9

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

10

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

11

Size-dependent surface plasmon resonance in silver silica nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Silver silica nanocomposites were obtained by the sol-gel technique using tetraethyl orthosilicate (TEOS) and silver nitrate (AgNO{sub 3}) as precursors. The silver nitrate concentration was varied for obtaining composites with different nanoparticle sizes. The structural and microstructural properties were determined by x-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). X-ray photoelectron spectroscopic (XPS) studies were done for determining the chemical states of silver in the silica matrix. For the lowest AgNO{sub 3} concentration, monodispersed and spherical Ag crystallites, with an average diameter of 5 nm, were obtained. Grain growth and an increase in size distribution was observed for higher concentrations. The occurrence of surface plasmon resonance (SPR) bands and their evolution in the size range 5-10 nm is studied. For decreasing nanoparticle ...

2008-02-20

13

Applications of X-ray scattering in pharmaceutical science  

British Library Electronic Table of Contents (United Kingdom)

The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.

2011-01-01

14

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, ...

2009-08-11

15

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

16

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

17

Structural intermediates in the assembly of taxoid-induced microtubules and GDP-tubulin double rings: time-resolved X-ray scattering.  

UK PubMed Central (United Kingdom)

We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available

1996-05-01

18

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

19

[Dependence of scattered Mn K alpha / K beta X-ray intensity ratio on the scatterer materials].  

Science.gov (United States)

The K alpha / K beta ratio of Mn KX-rays scattered by metallic samples changed remarkably with the geometry between the sample and the (55)Fe source-Si(Li) detector system. On the contrary, this intensity ratio changed little in the cases of non-metallic scatterer samples such as lucite or mylar. This difference is interpreted as due to the occurrence of strong or weak interference in the coherent scattering photons. PMID:7280291

1980-10-01

20

Determination of size distribution of Guinier-Preston zones in Al-Ag alloys by small-angle x-ray scattering method  

International Nuclear Information System (INIS)

Small-angle X-ray scattering method recognised to be very useful in the studies of structural problems of materials in homogeneous in nanoscale. Studies by small-angle X-ray scattering on the Al-Ag alloys are presented. The size distributions of spherical Guinier-Person zones were calculated using Vonk's and Glatter's methods. Small-angle X-ray scattering studies were performed on Al-5.0 at.%Ag alloy containing Guinier-Preson zones in the #eta#-state. For this alloy one can assume that scattering particles are of spherical shape, have uniform electron density and scatter independently. Moreover, the size distributions were calculated for Al-1.6 at.%Ag alloy containing Guinier-Preston zones in #epsilon#-state (scattering particles with not uniform electron density). Both, Vonk's and Glatter's, methods ...

2001-09-23

21

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

22

Study on wavelength shortening and upgrading of the free electron laser (FEL)  

International Nuclear Information System (INIS)

This study is a task of ''Comprehensive study'' in ''nuclear energy basic technology research'', which is promoted under cooperation of four research institutes. The Electrotechnical Laboratory conducted, in 1991 in the first period of colaboration, on successful oscillation at visible region (598 nm) as the first case in Japan, construction of small type accumulation ring NIJI-IV for FEL, successful oscillation of visible range from 595 to 488 nm by installing optical krystron with maximum frequency in the world, and successful emittance lowering of accumulation beam by wide improvement of the ring. In the optical resonator, studies on minute loss measuring technique and on recovery from mirror deterioration were promoted. In the second period started from fiscal year of 1994, studies on FEL oscillation technique in short wavelength and upgrading of FEL corresponding to a frontier area were started, to succeed an oscillation experiment at 350 nm in ultraviolet ...

23

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the ...

2010-03-15

24

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and ...

2005-01-01

25

Inelastic electron scattering, M1 giant resonances and the quest for subnuclear degrees of freedom  

International Nuclear Information System (INIS)

... electrons fine structure giant resonance inelastic scattering iron 54 iron 54

1983-01-17

26

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

27

Interference phenomena at the elastic collision of atoms with formation of the Feshbach resonance in the presence of laser radiation field  

British Library Electronic Table of Contents (United Kingdom)

Resonant scattering of atoms with formation of the Feshbach resonance in the presence of a laser radiation coupling the levels of two bound atoms (a molecule) is considered. The laser field leads to a second resonance in scattering and broadening of resonances, which facilitates the possibility of experimental observation of asymmetry of the total scattering cross-section arising because of interference between resonant and potential scatterings. The effects associated with interference of the two channels of decay of a bound system of two atoms (a molecule) in the laser field are studied. An expression is obtained for the scattering length in collision of two cold atoms in the field of laser radiation.

2011-01-01

28

Electronic spectra of semiconductor nanocrystals  

Energy Technology Data Exchange (ETDEWEB)

Semiconductor nanocrystals smaller than the bulk exciton show substantial quantum confinement effects. Recent experiments including Stark effect, resonance Raman, valence band photoemission, and near edge X-ray adsorption will be used to put together a picture of the nanocrystal electronic states.

1993-12-31

29

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

30

The inhomogeneous structure of water at ambient conditions  

UK PubMed Central (United Kingdom)

Small-angle X-ray scattering (SAXS) is used to demonstrate the presence of density fluctuations in ambient water on a physical length-scale of ≈1 nm; this is retained with decreasing temperature...Full Text Available

2009-09-08

31

Temperature Dependence of Structure, Bending Rigidity, and Bilayer Interactions of Dioleoylphosphatidylcholine Bilayers  

UK PubMed Central (United Kingdom)

X-ray diffuse scattering was measured from oriented stacks and unilamellar vesicles of dioleoylphosphatidylcholine lipid bilayers to obtain the temperature dependence of the structure and of the material...Full Text Available

2008-01-01

32

Inelastic x-ray scattering of dense solid oxygen: Evidence for intermolecular bonding  

UK PubMed Central (United Kingdom)

The detailing of the intermolecular interactions in dense solid oxygen is essential for an understanding of the rich polymorphism and remarkable properties of this element at high pressure. Synchrotron...Full Text Available

2008-08-19

33

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/  

International Nuclear Information System (INIS)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

34

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58. 8/U/sub 20. 6/Si/sub 20. 6/  

Energy Technology Data Exchange (ETDEWEB)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

1986-07-07

35

The pre-outburst flare of the A 0535+26 August/September 2005 outburst  

CERN Document Server

We study the spectral and temporal behavior of the High Mass X-ray Binary A 0535+26 during a `pre-outburst flare' which took place ~5 d before the peak of a normal (type I) outburst in August/September 2005. We compare the studied behavior with that observed during the outburst. We analyse RXTE observations that monitored A 0535+26 during the outburst. We complete spectral and timing analyses of the data. We study the evolution of the pulse period, present energy-dependent pulse profiles both at the initial pre-outburst flare and close to outburst maximum, and measure how the cyclotron resonance-scattering feature (hereafter CRSF) evolves. We present three main results: a constant period P=103.3960(5)s is measured until periastron passage, followed by a spin-up with a decreasing period derivative of Pdot=(-1.69+/-0.04)x10^(-8)s/s at MJD 53618, and P remains constant again at the end of the main outburst. The spin-up provides evidence for the ...

2008-01-01

36

Dependence of scattered Mn K sub(#alpha#)/K sub(#beta#) x-ray intensity ratio on the scatterer materials  

International Nuclear Information System (INIS)

The K sub(#alpha#)/K sub(#beta#) intensity ratio of Mn KX-rays scattered by metallic samples changed remarkably with the geometry between the sample and the "5"5Fe source-Si(Li) detector system. On the contrary, this intensity ratio changed little in the cases of non-metallic scatterer samples such as lucite or mylar. This difference is interpreted as due to the occurrence of strong or weak interference in the coherent scattering photons. (author).

1980-01-01

37

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was ...

2001-04-01

38

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated ...

2001-04-01

39

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution ...

2007-01-01

40

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by ...

1987-05-13

41

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer ...

2005-07-12

42

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer ...

2005-04-17

43

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

44

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ...

1987-01-01

45

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared ...

1987-01-01

46

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard ...

2009-09-01

47

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

48

Dynamics of spontaneous radiation of atoms scattered by a resonance standing light wave  

International Nuclear Information System (INIS)

The scattering of atoms by a resonance standing light wave is considered under conditions when the lower of two resonance levels is metastable, while the upper level rapidly decays due to mainly spontaneous radiative transitions to the nonresonance levels of an atom. The diffraction scattering regime is studied, when the Rabi frequency is sufficiently high and many diffraction maxima are formed due to scattering. The dynamics of spontaneous radiation of an atom is investigated. It is shown that scattering slows down substantially the radiative decay of the atom. The regions and characteristics of the power and exponential decay are determined. The adiabatic and nonadiabatic scattering regimes are studied. It is shown that the wave packets of atoms in the metastable and resonance excited states narrow down during ...

2003-09-01

49

X-ray observation of a. sqrt. 3 x. sqrt. 3 superlattice in KC/sub 8/ at high pressure  

Energy Technology Data Exchange (ETDEWEB)

A single-crystal x-ray study under pressure reveals a phase transition from an in-plane 2x2 commensurate potassium superstructure to a new ..sqrt..3x..sqrt..3 commensurate superstructure. This is the first such transition to be observed; it is related to the recently discovered staging transition of KC/sub 8/ under pressure. In addition this staging transition was observed to occur more slowly and at much lower pressures than in the reported neutron-scattering experiment on highly oriented pyrolytic graphite samples. 13 references, 2 figures.

1985-05-15

50

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

51

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

53

Lifetime of 2.734 mev Sr"8"8 level  

International Nuclear Information System (INIS)

... range 01-10 nuclei photons radiation sources recoils resonance scattering

54

Water structure as a function of temperature from X-ray scatteringexperiments and ab initio molecular dynamics  

Energy Technology Data Exchange (ETDEWEB)

We present high-quality X-ray scattering experiments on pure water taken over a temperature range of 2 to 77 C using a synchrotron beam line at the advanced light source (ALS) at Lawrence Berkeley National Laboratory. The ALS X-ray scattering intensities are qualitatively different in trend of maximum intensity over this temperature range compared to older X-ray experiments. While the common procedure is to report both the intensity curve and radial distribution function(s), the proper extraction of the real-space pair correlation functions from the experimental scattering is very difficult due to uncertainty introduced in the experimental corrections, the proper weighting of OO, OH, and HH contributions, and numerical problems of Fourier transforming truncated data in Q-space. Instead, we consider the direct calculation of X-ray ...

2003-03-01

55

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

56

Small angle X-ray scattering on concentrated hemoglobin solutions  

International Nuclear Information System (INIS)

The small-angle X-ray scattering technique was used to determine the intermolecular structure and interaction potentials in oxi-and deoxi-hemoglobin solutions. The pair correlation function obtained by the ZERNICKE-PRINS equation characterizes the intermolecular structure of the hemoglobin molecules. The intermolecular structure is concentration dependent. The hemoglobin molecules have a 'short range order structure' with a range of about 4 molecule diameters at 324 g/l. The potential functions of the hemoglobin-hemoglobin interaction have been determined on the basis of fluid theories. Except for the deoxi-hemoglobin solution having the concentration 370 g/l, the pair interaction consists in a short repulsion and a weak short-range attraction against kT. The potential minimum is between 1.2 - 1.5 nm above the greatest hemoglobin diameter. (author).

58

X-ray absorption spectroscopy, EELS, and full-potential augmented plane wave study of the electronic structure of Ti_2AlC, Ti_2AlN, Nb_2AlC, and (Ti_0_._5Nb_0_._5)_2AlC  

International Nuclear Information System (INIS)

The structural parameters of various Haegg phases (H or M_n_+_1AX_n phases) are studied experimentally by x-ray and electron spectroscopies, x-ray diffraction, and ab initio full potential as well as full mutiple scattering theoretical calculations. Experimentally it was found that the structure of all ternary compounds analyzed herein are relaxed. The values of the lattice parameters and relaxations obtained from ab initio calculations are in excellent agreement with those deduced from the analysis of the experimental data. The bonding scheme has been analyzed and the charge transfer between constituting atoms determined. It is demonstrated that the strength and electrical transport properties in these materials are principally governed by the metallic planes. For the solid solution (Ti_0_._5Nb_0_._5)_2AlC, the most salient result is that the basal planes are corrugated, which could explain the solid solution ...

2005-01-01

59

Resonance scattering of Lyman-. cap alpha. radiation by hydrogen in the ground state  

Energy Technology Data Exchange (ETDEWEB)

We calculate the cross section for the resonance scattering of Lyman-..cap alpha.. radiation by spinless nonrelativistic hydrogen atoms in the ground state using a two-level model. A generalization of Dirac's resonance scattering theory is used together with the exact matrix elements for the electromagnetic interaction. In contrast to the usual treatments in which only the dipole approximation for the matrix elements are taken, the shift in position of the resonance is finite and has a value of 75% of the Lamb shift of the n=1 state. Whether this latter fact is significant in renormalization calculations is left open.

1980-11-01

60

Nonformity of the electron density in amorphous silicon films  

Energy Technology Data Exchange (ETDEWEB)

The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.

1985-12-01

61

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

62

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and ...

2008-04-01

63

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region observations. I have approached two astrophysical ...

2005-01-15

64

SAXS studies on added-salt species dependence of conformation of fully-charged poly(L-glutamate) in aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

The effect of counter-ion species on the local conformation of fully-charged poly(L-glutamate) in added-salt aqueous solutions were studied by small-angle X-ray scattering(SAXS). In the case of presence of monovalent counter-ion, the scattering behaviour could be explained by taking into consideration the excluded volume effect and intermolecular-interface interaction on the scattering function of wormlike chain. On the other hand, since SAXS profile of the solution in the presence of divalent counter-ion well fitted to the scattering function of dendrimer, it suggested that the conformation of polymer chain in such solution would be more compact conformation than that of presence of monovalent ion.

2010-10-01

65

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

66

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

67

Finite element analysis of a scanning x-ray microscope micropositioning stage  

Energy Technology Data Exchange (ETDEWEB)

A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.

1992-01-01

68

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

69

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

70

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of ...

2007-07-25

71

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

72

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements ...

2009-09-01

73

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon ...

2009-05-01

74

How epitaxial are Pd/sub 2/Si-Si interfaces  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si layers produced by evaporation or sputtering onto silicon substrates were examined by high resolution electron microscopy, microdiffraction, X-ray, energy loss and Auger spectroscopy. The Si-Pd/sub 2/Si interfaces produced by evaporation were in all cases rougher and more polycrystalline than those produced by sputtering. X-ray microanalysis showed the predictable variation in palladium distribution across the interface but quantification did not produce the expected palladium-to-silicon ratios, primarily because of probe broadening and X-ray-induced fluorescence. Energy loss spectra showed plasmon energy shifts and changes in Si L edge shape due to bond formation with palladium. Auger data provided evidence for a small amount of oxygen at the Si-Pd/sub 2/Si interface. Electrical measurements of the ideality factor for Schottky barriers made from the materials produced higher values for the rougher ...

1983-06-17

75

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a silicon mirror after ion erosion at various ...

2010-05-01

76

Duality in Neutrino Reactions  

Energy Technology Data Exchange (ETDEWEB)

On the basis of the phenomenological model for baryon resonance production in lepton nucleon and lepton nucleus scattering we investigate to what extent quark hadron duality is applicable to the neutrino structure functions and how it compares with duality in electron scattering.

2007-12-01

77

Phenomenological and microscopical description of scattering on different dislocation arrangements  

Energy Technology Data Exchange (ETDEWEB)

Two approaches are used to analyse X-ray or neutron scattering by crystals with different dislocation ensembles. Analogy between the above concepts is discussed. The microscopical approach takes into account the detailed displacement field due to different types of dislocation arrangement in the crystal. Frequently a phenomenological concept operating with the ideas of displacements, strains and stresses arising in the materials under deformation is applied. Unfortunately, the phenomenological concept cannot take into account that similar stress distributions may have significantly different microscopic reasons. The comparison of the results obtained by both phenomenological and microscopic descriptions of scattering enables us to understand the connection between different types of strains and stresses in the crystal with the type of the defects in it. (orig.)

2001-01-01

78

Investigation of the structure of nano-porous carbon obtained from polycrystal carbides by means of small-angle X-ray diffraction  

International Nuclear Information System (INIS)

The structure of nano-porous carbon, obtained by means of chlorination of carbide compounds with various crystal structure (SiC, TiC, Mo_2C) is studied through the method of small-angle diffraction. The angular dependences of the scattering intensity obtained are interpreted as the result of scattering from the nanoparticles of different size. The functions of the scattering particles distribution by the m(R_g) inertia radii are determined. It is shown that in spite of the source carbide, the highest fraction of the volume in the porous carbon constitute the particles with R_g #approx# 5 A. The nanoparticles in the samples obtained from SiC, wherein the average value of the R_g"a"v < 6 A, are most uniform by size. The nanoparticles in the porous carbon, obtained from Mo_2C, are on the average by two times larger

1999-08-01

79

Assessment of the supramolecular structures presents into biological samples by SAXS technique;Avaliacao das estrutras supramoleculares presentes em amostras biologicas atraves da tecnica de SAXS  

Energy Technology Data Exchange (ETDEWEB)

In this work was made an assessment of the supramolecular structures presents into human breast tissue normal and pathological samples, as well as into two types of animals samples (tendon chicken and pork fat) using the small angle x-ray scattering (SAXS) technique. The scattering profiles of the samples were determined at the momentum transfer range O.150nm{sup -1}<=5:q(=4pi.sin({theta}/2)/{lambda})<=8.500nm{sup -1}. In this range, it was possible identify structures corresponding to collagen fibrils (glandular tissue) and to triacylglycerides (adipose tissue) from the correlation between the information extracted from the human breast tissues scattering profiles and those extracted from animals samples. (author)

2009-07-01

80

PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS  

International Nuclear Information System (INIS)

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft ...

2009-09-01

81

Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs  

Energy Technology Data Exchange (ETDEWEB)

The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible ...

1999-02-23

82

Application of neutron diffraction in chemistry. Pt. 2  

Energy Technology Data Exchange (ETDEWEB)

This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a combination of several neutron scattering ...

1982-01-01

83

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

84

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

85

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

86

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

87

Determination of Scaling Parameter and Dynamical Resonances in Complex-Rotated Hamiltonian II: Numerical Analysis  

International Nuclear Information System (INIS)

This paper is concerned with the determination of a unique scaling parameter in complex scaling analysis and with accurate calculation of dynamics resonances. In the preceding paper we have presented a theoretical analysis and provided a formalism for dynamical resonance calculations. In this paper we present accurate numerical results for two non-trivial dynamical processes, namely, models of diatomic molecular predissociation and of barrier potential scattering for resonances. The results presented in this paper confirm our theoretical analysis, remove a theoretical ambiguity on determination of the complex scaling parameter, and provide an improved understanding for dynamical resonance calculations in rigged Hilbert space.

2008-03-15

88

Multi-channel algebraic scattering theory and the structure of exotic compound nuclei  

CERN Document Server

A Multi-Channel Algebraic Scattering (MCAS) theory is presented with which the properties of a compound nucleus are found from a coupled-channel problem. The method defines both the bound states and resonances of the compound nucleus, even if the compound nucleus is particle unstable. All resonances of the system are found no matter how weak and/or narrow. Spectra of mass-7 nuclei and of {}^{15}F, and MCAS results for a radiative capture cross section are presented.

2007-01-01

89

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

90

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

91

Ion beam analysis of high temperature superconducting samples  

Energy Technology Data Exchange (ETDEWEB)

Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).

1994-02-01

92

Inhomogeneity of electron density in amorphous films  

International Nuclear Information System (INIS)

By the methods of small-angle X-ray scattering and translucent electron microscopy the existence of inhomogeneity of electron density in hydrogenated films of amorphous silicon is confirmed. The decreased density regions are extended and form a branched network of channels oriented mostly by the normal direction to the films surface. The typical size of the decreased density regions network constitutes 10 nm in the 100-800 nm films thickness range. The increase of hydrogen total partial pressure in gas mixture in case of films growth results at first in the decrease of extension of these regions and than to micropores generation in the network nodal points of the decreased electron density regions.

93

Atomic photoelectric effect near threshold edges  

Energy Technology Data Exchange (ETDEWEB)

Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub ..cap alpha..//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.

1985-07-01

94

Atomic photoelectric effect near threshold edges  

International Nuclear Information System (INIS)

Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub #alpha#//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.

1985-01-01

95

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...

2010-11-24

96

Review of High Gain FELs  

Science.gov (United States)

For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons ...

2007-01-19

101

Excitation of 1/sup +/ states in /sup 88/Sr by proton inelastic scattering  

Energy Technology Data Exchange (ETDEWEB)

In a (p,p') study of /sup 88/Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1/sup +/ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1/sup +/ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%.

1985-06-10

102

Excitation of 1"+ states in "8"8Sr by proton inelastic scattering  

International Nuclear Information System (INIS)

In a (p,p') study of "8"8Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1"+ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1"+ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%. (orig.).

103

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

104

Highly excited spin-1 states in "8"8Sr by the (#gamma#,#gamma#) reaction  

International Nuclear Information System (INIS)

The resonant scattering of bremsstrahlung #gamma#-rays by a SrCO_3 target has been studied for #gamma#-ray energies of 5-11 MeV. Six #gamma#-transitions of energies between 6-8 MeV, which indicate six resonant states in "8"8Sr, were observed. The relative intensities of the resonantly scattered #gamma#-rays at 125 and 150"0 were found to be compatible only with the assignment of spin 1 to the six states. Radiative widths of the resonant states were deduced. The possibility that these states are components of the giant M1 resonance in "8"8Sr is discussed. (orig.).

105

Structural changes in amorphous Pd/sub 80/Si/sub 20/ by neutron irradiation  

Science.gov (United States)

Amorphous Pd/sub 80/Si/sub 20/ was irradiated with fast neutrons (>1 MeV) to a fluence of 5 x 10/sup 20/ neutrons/cm/sup 2/. X-ray scattering intensities were measured before and after the irradiation with monochromatic Cu-K..cap alpha../sub 1/ rays. Scattered intensities for s>0.4 A/sup -1/ (s=2 sintheta/lambda) proved unaffected, while intensities were found remarkably enhanced for s<0.4 A/sup -1/ after the irradiation, i.e., in the small-angle region and the leading edge of the first halo. The results are discussed in relation to the structural anomalies in amorphous solids.

1977-10-01

106

Real-time neutron scattering investigations of biological signal transduction dynamics  

Energy Technology Data Exchange (ETDEWEB)

During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France.

2005-07-01

107

Real-time neutron scattering investigations of biological signal transduction dynamics  

International Nuclear Information System (INIS)

During their catalytic cycle, proteins involved in biological signal transduction undergo unexpectedly large conformational changes, which are at the core of their biological functioning. Until now it has been extremely difficult to obtain experimental insight into the nature of these conformational changes. Mathematical modeling and time-resolved X-ray crystallography have resulted in probable routes along which these conformational changes may take place, but so far this fundamental biological phenomenon has hardly been tackled experimentally. Here, we report on an attempt to observe structural changes in Photoactive Yellow Protein with time-resolved small-angle neutron scattering using diffractometer D22 at the high-flux reactor of the Institut Laue-Langevin, Grenoble, France

2005-04-11

108

Diffuse X-ray scattering study of sublattice ordering among group III atoms in In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P  

International Nuclear Information System (INIS)

The intensity of superstructure reflections and associated diffuse scattering from In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P epitaxic layers grown on (001) GaAs substrates was mapped in reciprocal space. The Warren-Cowley short-range-order parameters were obtained through the usual process for evaluating Fourier coefficients. Varying values for the correlation length in different directions indicate how group III atoms stack up in ordered states. The resultant structure with long-range order confirms the hypothesis made on the basis of electron diffraction and high-resolution transmission electron microscopy studies. (orig.).

109

Measurement of the K-shell ionization probability across a wide resonance: /sup 88/Sr(p,p/sub 0/) at 6. 06 MeV  

Energy Technology Data Exchange (ETDEWEB)

We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.

1982-09-01

110

Crystal growth, structural and optical characterization of a semi-organic single crystal for frequency conversion applications  

International Nuclear Information System (INIS)

Single crystals of semi-organic L-histidine hydrobromide have been grown by slow evaporation technique from a mixture of L-histidine and hydrobromic acid in aqueous solution at ambient temperature. From high-resolution X-ray diffraction analysis, the crystalline perfection of the grown crystal has been studied. Single crystal X-ray diffraction analyses, Nuclear Magnetic Resonance spectral analysis, Thermo-Gravimetry (TG), Differential Thermal Analysis (DTA) and hardness test have been employed to characterize the as-grown crystals. The UV cutoff wavelength of the grown crystal is below 300 nm and has a wide transparency window, which is suitable for second harmonic generation of laser in the blue region. Nonlinear optical characteristics have been studied using Q switched Nd:YAG laser (#lambda#=1064 nm). The second harmonic generation conversion efficiency of the grown crystals confirms their suitability for frequency ...

2010-12-15

111

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic ...

2009-06-01

112

Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199  

CERN Document Server

The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are being accelerated to higher energies. We find ...

1999-01-01

113

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...

2005-01-01

114

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired ...

2007-08-01

115

Anisotropy in Magnetic Properties and Electronic Structure of Single Crystal LiFePO4  

Energy Technology Data Exchange (ETDEWEB)

We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different feature assignment for ...

2008-01-01

116

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

117

Potential description of cluster channel of lithium nuclei  

International Nuclear Information System (INIS)

The new Gaussian potentials and interactions with forbidden states consistent with the phase scattering at low energies were obtained. Cross sections, resonance level spectra and some characteristics of bound states of lithium nuclei are calculated with these potentials.

118

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition ...

2009-10-01

119

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

120

Microstructure modifications and modulated piezoelectric responses in PLZT/Al{sub 2}O{sub 3} composites  

Energy Technology Data Exchange (ETDEWEB)

Piezoelectric ceramics for acoustic applications have been prepared by mixing the piezoelectric phase Pb{sub 1-1.5x}La{sub x}{open_square}{sub x/2}(Ti{sub 1-y}Zr{sub y})O{sub 3} (PLZT) with variable fractions of Al{sub 2}O{sub 3}. The samples are in form of pellets and polarized at high temperature. After thermal treatment, X-ray diffraction and scanning electron microscopy have been used to determine the phase and morphological modifications. The morphotropic PLZT initial phase disproportionates into modified PLZT and ZrO{sub 2} phases. Using electrical impedance spectroscopy, the resonance frequencies of the composite system have been determined and analyzed. As the Al{sub 2}O{sub 3} volume fractions increase, the resonance frequency and the amplitude of the electrical response both decrease. An interpretation of the role of Al{sub 2}O{sub 3} additions is proposed in terms of phase and microstructure modifications. Using ...

2003-01-15

121

Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence  

International Nuclear Information System (INIS)

The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in ...

2004-02-27

122

Analyses of superficial and depth doses in intraoral radiology  

Energy Technology Data Exchange (ETDEWEB)

In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...

2006-07-01

123

Visible light photocatalytic activity and Photoelectrochemical property of Fe-doped TiO2 hollow spheres by sol?gel method  

British Library Electronic Table of Contents (United Kingdom)

Fe-doped TiO2 hollow spheres (Fe-THs) were synthesized by sol?gel process using carbon spheres as templates. The prepared samples were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), UV?vis diffuse reflectance spectrum (DRS), N2 adsorption?desorption isotherms, Electron paramagnetic resonance (EPR) spectroscopy and Photoluminescence emission spectroscopy (PL). UV?vis spectra showed that Fe3+ doping could extend the absorption edge to the visible region. EPR spectra showed that Fe3+ was incorporated into the crystal lattice of TiO2, which could inhibit the recombination of photo-induced electron?hole pairs and improve the photocatalytic activity. The photocatalytic activities of the prepared samples were evaluated for the degradation of dye Reactive Brillia...

2011-01-01

124

Synthesis and characterization of myristic acid capped silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

Reduction of silver myristate (AgMy) under mild thermal reaction conditions in a dipolar aprotic solvent i.e. N, N-dimethylformamide (DMF) has been carried out. UV-visible absorption measurements of dried and re-dispersible brown flocculants showed broad features of surface plasmon resonance (SPR) due to silver nanoparticles. The freshly isolated particles showed absorption bands at 414 and 485 nm, respectively, due to inter-particle coupling or clustering of silver ions and silver atoms. X-ray diffraction (XRD) pattern of fcc zero-valent silver resulted in crystallite size of about 10 nm. Scanning electron microscopy (SEM) revealed formation of rod shaped silver with increasing reaction temperature. Thermal analysis (TGA) showed about 10% weight loss due to organic capping.

2008-08-15

125

Microstructure and atomic effects on the electroluminescent efficiency of SrS:Ce thin film devices  

International Nuclear Information System (INIS)

Transmission electron microscopy and x-ray diffraction data show that rapid thermal anneals of SrS:Ce thin films enhance grain size and reduce crystalline defects. Electron paramagnetic resonance results suggest that these anneals lead to less variance in the crystal field environments at the nearly cubic Ce"3"+ sites along with the formation of another type of Ce"3"+ site believed to involve a nearby Sr vacancy. We suggest that the association of Ce"3"+ sites with V_S_r shifts the electroluminescence towards larger wavelengths as the symmetry of the activator site is lowered. copyright 1997 American Institute of Physics.

126

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

127

Quark-Hadron Duality: Resonances and the Onset of Scaling  

Energy Technology Data Exchange (ETDEWEB)

We discuss the origin of Bloom-Gilman duality and the relationship between resonances and scaling in deep-inelastic scattering. We present a simple quantum mechanical model which reproduces the essential features of Bloom-Gilman duality at low Q{sup 2}, and describe applications of local duality relating structure functions at x{approximately}1 and elastic electromagnetic form factors.

2001-03-01

128

Virtual Compton Scattering: Results from Jefferson Lab  

Energy Technology Data Exchange (ETDEWEB)

Virtual Compton Scattering o013 the proton has been studied at Q 2 -values of 1:0 and 1:9 (GeV=c) 2 in Hall A at the Thomas Je013erson National Accelerator Facility (JLab). Data were taken below and above the pion production threshold as well as in the resonance region. Results obtained below pion threshold at Q 2 = 1:0 (GeV=c) 2 are presented in this paper.

2003-05-01

129

Spiral modes in the diffusion of a single granular particle on a vibrating surface  

International Nuclear Information System (INIS)

We consider a particle that is subject to a constant force and scatters inelastically on a vibrating periodically corrugated floor. At small friction and for small scatterers the dynamics is dominated by resonances forming spiral structures in phase space. These spiral modes lead to pronounced maxima and minima in the diffusion coefficient as a function of the vibration frequency, as is shown in computer simulations. Our theoretical predictions may be verified experimentally by studying transport of single granular particles on vibratory conveyors.

2004-11-29

130

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

131

Kinetics of pore coarsening in glassy carbon  

Energy Technology Data Exchange (ETDEWEB)

One third of the microstructure of glassy carbon (GC) consists of closed pores. Density measurements indicate that the total pore volume depends only on the heat treatment temperature and not on the heat treatment time, a characteristic of coarsening. The kinetics of coarsening of these pores on heat treatment has been investigated by analyzing the changes in specific surface area of the pores as determined by the small angle X-ray scattering (SAXS) technique. A part of the surface area change is due to thermal expansion induced microcracking. Both the superposition method after correcting the thermal expansion induced surface area change and the curve fitting method give an activation energy of 64 +/- 10 kcal/mole. This value is compared with the activation energies of various rate processes in graphite. A model of coarsening of the pores based on a vacancy migration mechanism is proposed.

1981-01-01

132

Ion beam induced damage and element loss during a microanalysis of biological tissue  

Energy Technology Data Exchange (ETDEWEB)

Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).

1991-03-01

133

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

134

High resolution electron microscopy study of as-prepared and annealed tungsten-carbon multilayers  

International Nuclear Information System (INIS)

A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.

135

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

136

CHARACTERIZATION OF DEXTRIN PREPARED BY COMMON NEUTRAL AND THERMOSTABLE a-AMYLASES  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT With corn starch as raw material, dextrin was prepared by the combined application of common neutral and thermostable a-amylases in this study. The effects of reaction temperature, reaction time, addition of common neutral and thermostable a-amylases on dextrose equivalent (DE)-value of dextrin were investigated. The obtained dextrin with a DE value of 20.43 was evaluated for morphology, crystallography, particle size distribution and thermal property by scanning electron microscope, X-ray diffractometer, light scattering particle size analyzer and thermogravimetric analyzer. The results showed that the amorphous regions in the core part of corn starch were completely hydrolyzed and only the fractured crystalline surface remained. The particle size of the dextrin change significan...

2010-01-01

137

Banana peel extract mediated novel route for the synthesis of palladium nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

Bio-inspired palladium nanoparticles were synthesized by using banana peel extract (BPE), a non-toxic eco-friendly material. Boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce palladium chloride. The palladium nanoparticles were characterized by using UV-Visible spectroscopy, scanning electron microscope-energy dispersive spectra (SEM-EDS) and X-ray diffraction (XRD) analysis. Dynamic light scattering (DLS) studies revealed the average size of nanoparticles to be 50nm. Fourier transform infra red spectroscopy (FTIR) implicated the role of carboxyl, amine and hydroxyl groups in the synthetic process. This paper thus describes a novel green method for the synthesis of palladium nanoparticles.

2010-01-01

138

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

139

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

140

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

141

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

142

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

143

Interplay of quark and meson degrees of freedom in a near-threshold resonance  

Energy Technology Data Exchange (ETDEWEB)

We investigate the interplay of quark and meson degrees of freedom in a physical state representing a near-threshold resonance for the case of a single continuum channel. We demonstrate that such a near-threshold resonance may possess quite peculiar properties if both quark and meson dynamics generate weakly coupled near-threshold poles in the S -matrix. In particular, the scattering t -matrix may possess zeros in this case. We also discuss possible implications for production reactions as well as studies within lattice QCD. (orig.)

2010-04-15

144

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

145

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

146

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

148

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

149

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

150

Spectral properties of cylindrical quasioptical cavity resonator with random inhomogeneous side boundary.  

Science.gov (United States)

A rigorous solution for the spectrum of a quasioptical cylindrical cavity resonator with a randomly rough side boundary has been obtained. To accomplish this task, we have developed a method for the separation of variables in a wave equation, which enables one, in principle, to rigorously examine any limiting case-from negligibly weak to arbitrarily strong disorder at the resonator boundary. It is shown that the effect of disorder-induced scattering can be properly described in terms of two geometric potentials, specifically, the "amplitude" and the "gradient" potentials, which appear in wave equations in the course of conformal smoothing of the resonator boundaries. The scattering resulting from the gradient potential appears to be dominant, and its impact on the whole spectrum is governed by the unique sharpness parameter ?, the mean tangent of the asperity slope. As opposed to ...

2011-08-30

151

Effect of dysprosium doping on the optical properties of SrS:Dy,Cl phosphor  

International Nuclear Information System (INIS)

The fundamental optical properties of dysprosium (Dy) doped strontium sulfide bulk samples for various dopant concentrations from 0.1 to 1.0 at.% were investigated by X-ray diffraction (XRD), electron paramagnetic resonance spectroscopy (EPR), room temperature photoluminescence (PL), photoluminescence excitation (PLE) and diffuse reflectance spectroscopy (DRS). Investigations by electron paramagnetic resonance yielded the state of Dy in the sample as Dy3+. An additional ESR line due to F+ center was observed. The PL emission spectrum consisted of several intense lines and a number of weaker ones which were identified as transitions between energy levels of Dy3+. The optimum doping concentration for maximum intensity was found to be 0.25 at.%. Blue shift of the absorption edge energy and red shift of the PLE spectrum were observed with increasing doping concentration. The former is due to Burstein-Moss (BM) effect and the ...

2010-08-13

152

Contrasting Kondo behavior and resonant inverse photoemission spectra of CeTSi{sub 3} and CeTGe{sub 3} (T=Rh and Ir)  

Energy Technology Data Exchange (ETDEWEB)

We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)

1999-02-28

153

The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations  

International Nuclear Information System (INIS)

Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs ...

2002-07-01

154

Materials research and beam line operation utilizing NSLS. Progress report  

Energy Technology Data Exchange (ETDEWEB)

MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year the full 242 operational days were utilized. Beam line test and evaluation consumed 21 days with eight MATRIX groups combining to use 170 days. General user demand for use of the beam line continues to be strong and three groups were provided 51 operating days. Research production has been growing as NSLS and the beam line become a more stable type of operation. For 1990 the ...

1991-10-01

155

Precise characterisation of nanochannels in track etched membranes by SAXS and SANS  

Energy Technology Data Exchange (ETDEWEB)

Poster session: Abstract is full text. Track membranes are thin polymer foils irradiated by heavy ions. The defects created by the heavy ions are located along the ions trajectory, the track. It is possible to open channels by etching with a chemical agent. These channels are very uniform. Small Angle Scattering (of X rays and neutrons) give global information about the characteristics of the channel shape. As the nanochannels are strictly parallel, an excellent sample orientation is required to obtain interpretable spectra. Then shoulders due to the oscillations of the Bessel function (radial part of the channel shape Fourier transform) are easily seen in the scattered intensity in the PXY data treatment software of SAS spectra allow to determine the channel diameter with its dispersion law, to demonstrate the existence of a wall thickness with a linearly varying density, and to assess the roughness. ...

2003-05-01

156

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS ...

2006-12-01

157

Aggregation of silica nanoparticles directed by adsorption of lysozyme.  

Science.gov (United States)

The interaction of the globular protein lysozyme with silica nanoparticles of diameter 20 nm was studied in a pH range between the isoelectric points (IEPs) of silica and the protein (pH 3-11). The adsorption affinity and capacity of lysozyme on the silica particles is increasing progressively with pH, and the adsorbed protein induces bridging aggregation of the silica particles. Structural properties of the aggregates were studied as a function of pH at a fixed protein-to-silica concentration ratio which corresponds to a surface concentration of protein well below a complete monolayer in the complete-binding regime at pH > 6. Sedimentation studies indicate the presence of compact aggregates at pH 4-6 and a loose flocculated network at pH 7-9, followed by a sharp decrease of aggregate size near the IEP of lysozyme. The structure of the bridged silica aggregates was studied by cryo-transmission electron microscopy (cryo-TEM) and small-angle X-ray ...

2011-07-20

158

Quark-hadron duality in neutrino scattering  

Energy Technology Data Exchange (ETDEWEB)

We present a phenomenological model of the quark-hadron transition in neutrino-nucleon scattering. Using recently extracted weak nucleon transition form factors, we investigate the extent to which local and global quark-hadron duality is applicable in the neutrino F{sub 1}, F{sub 2} and F{sub 3} structure functions, and contrast this with duality in electron scattering. Our findings suggest that duality works relatively well for neutrino-nucleon scattering for the F{sub 2} and F{sub 3} structure functions, but not as well for F{sub 1}. We also calculate the quasi-elastic, resonance and deep inelastic contributions to the Adler sum rule, and find it to be satisfied to within 10% for 0.5 < Q{sup 2} < 2 GeV{sup 2}.

2006-07-24

161

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

162

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

168

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

169

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

170

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

171

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

172

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

176

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

177

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

178

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

179

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

180

Modelling fragmentations of amino-acids after resonant electron attachment: quantum evidence of possible direct -OH detachment  

International Nuclear Information System (INIS)

We investigate some aspects of the radiation damage mechanisms in biomolecules, focusing on the modelling of resonant fragmentation caused by the attachment of low-energy electrons (LEEs) initially ejected by biological tissues when exposed to ionizing radiation. Scattering equations are formulated within a symmetry-adapted, single-center expansion of both continuum and bound electrons, and the interaction forces are obtained from a combination of ab initio calculations and a nonempirical model of exchange and correlation effects developed in our group. We present total elastic scattering cross-sections and resonance features obtained for the equilibrium geometries of glycine, alanine, proline and valine. Our results at those geometries of the target molecules are briefly shown to qualitatively explain some of the fragmentation patterns obtained in experiments. We further carry out a one-dimensional ...

2010-10-01

181

Compound elastic cross sections in the isobaric analog resonances /sup 88/Sr(p,p/sub 0/) at 5. 06 MeV and /sup 86/Sr(p,p/sub 0/) at 6. 02 MeV  

Energy Technology Data Exchange (ETDEWEB)

We have measured the K-shell ionization probability Psub(K) across the isobaric analog resonances in the elastic channel of the reactions /sup 88/Sr(p, p/sub 0/)/sup 88/Sr at 5.06 MeV and /sup 86/Sr(p, p/sub 0/)/sup 86/Sr at 6.02 MeV. The dependence of Psub(K) on the beam energy for two scattering angles 90/sup 0/ and 155/sup 0/ is analysed in the framework of the theory developed by Anholt et al. taking into account the effect of compound-nucleus scattering. A compound elastic cross section (dsigma/d..cap omega..)sub(CE)=40+-10 mb/se at the peak of the resonance is deduced in the reaction /sup 88/Sr+p at 5.06 MeV, while the experimental results agree with a negligible value of (dsigma/d..cap omega..)sub(CE) for the resonance in /sup 86/Sr+p at 6.02 MeV.

1983-10-27

182

Compound elastic cross sections in the isobaric analog resonances "8"8Sr(p,p_0) at 5.06 MeV and "8"6Sr(p,p_0) at 6.02 MeV  

International Nuclear Information System (INIS)

We have measured the K-shell ionization probability Psub(K) across the isobaric analog resonances in the elastic channel of the reactions "8"8Sr(p, p_0)"8"8Sr at 5.06 MeV and "8"6Sr(p, p_0)"8"6Sr at 6.02 MeV. The dependence of Psub(K) on the beam energy for two scattering angles 90"0 and 155"0 is analysed in the framework of the theory developed by Anholt et al. taking into account the effect of compound-nucleus scattering. A compound elastic cross section (dsigma/d#OMEGA#)sub(CE)=40+-10 mb/se at the peak of the resonance is deduced in the reaction "8"8Sr+p at 5.06 MeV, while the experimental results agree with a negligible value of (dsigma/d#OMEGA#)sub(CE) for the resonance in "8"6Sr+p at 6.02 MeV. (orig.).

183

Efficient Cartesian-grid-based modeling of rotationally symmetric bodies  

DEFF Research Database (Denmark)

Axially symmetric waveguides, resonators, and scatterers of arbitrary cross section and anisotropy in the cross section can be modeled rigorously with use of 2-D Cartesian-grid based codes by means of mere redefinition of material permittivity and permeability profiles. The method is illustrated by the frequencydomain simulations of resonant modes in a circular-cylinder cavity with perfectly conducting walls, a shielded uniaxial anisotropic dielectric cylinder, and an open dielectric sphere for which, after proper implementation of the perfectly matched layer boundary conditions, the radiation quality factor is also determined.

2007-01-01

184

Sensitivity to alpha-variation in ultracold atomic-scattering experiments  

CERN Document Server

We present numerical calculations for cesium and mercury to estimate the sensitivity of the scattering length to the variation of the fine structure constant alpha. The method used follows ideas Chin and Flambaum [Phys. Rev. Lett. 96, 230801 (2006)], where the sensitivity to the variation of the electron to proton mass ratio, beta, was considered. We demonstrate that for heavy systems, the sensitivity to variation of alpha is of the same order of magnitude as to variation of beta. Near narrow Feshbach resonances the enhancement of the sensitivity may exceed nine orders of magnitude.

2011-01-01

185

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce ...

2005-09-07

186

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

187

Effects of inorganic cation templates on octahedral molecular sieves of manganese oxide  

Science.gov (United States)

Five hydrated inorganic divalent cations, Mg[sup 2+], Co[sup 2+], Ni[sup 2+], Cu[sup 2+], and Zn[sup 2+], have successfully been used as templates for the synthesis of manganese oxide octahedral molecular sieves (OMS-1) having the todorokite structure. The OMS-1 samples have been well characterized by X-ray diffraction, differential scanning calorimetry, thermogravimetric analysis, scanning electron microscopy/energy dispersive X-ray studies, inductively coupled plasma analysis, electron paramagnetic resonance, Fourier transform infrared spectroscopy, thiosulfate titration, and cyclohexane sorption. Catalytic CO oxidation and 2-propanol decomposition were carried out. Results show that these OMS-1 samples with a tunnel size of about 6.9 angstroms are crystalline and chemically pure. They have the following formulas: Mg[sub 3.17]Mn[sub 5.05]O[sub 12] [center dot] 4.52H[sub 2]O, Co[sub 1.84]Mn[sub 5.59]O[sub 12] [center dot] ...

1994-11-30

188

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...

2000-08-01

189

Control of Electrostatic Interactions Between F-Actin And Genetically Modified Lysozyme in Aqueous Media  

Science.gov (United States)

The aim for deterministic control of the interactions between macroions in aqueous media has motivated widespread experimental and theoretical work. Although it has been well established that like-charged macromolecules can aggregate under the influence of oppositely charged condensing agents, the specific conditions for the stability of such aggregates can only be determined empirically. We examine these conditions, which involve an interplay of electrostatic and osmotic effects, by using a well defined model system composed of F-actin, an anionic rod-like polyelectrolyte, and lysozyme, a cationic globular protein with a charge that can be genetically modified. The structure and stability of actin-lysozyme complexes for different lysozyme charge mutants and salt concentrations are examined by using synchrotron x-ray scattering and molecular dynamics simulations. We provide evidence that supports a structural transition from columnar ...

2009-06-04

190

On the temperature sensing capability of a fibre optic SPR mechanism based on bimetallic alloy nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

In this work, we have investigated the capability of different bimetallic nanoparticle alloy combinations to be used in fibre optic temperature sensing based on the technique of surface plasmon resonance (SPR). The metals considered for the present analysis are silver, gold and aluminium. The analysis is derived mainly from the thermo-optic effect along with some fundamental concepts of metal optics such as surface scattering, phonon-electron scattering and electron-electron scattering. The performance of the sensor with three different bimetallic nanoparticle alloy combinations is evaluated and compared, numerically, in terms of its sensitivity and accuracy. On the basis of the comparison and some logistic criterion, we predict the best possible bimetallic alloy combination along with a requisite alloy composition ratio that simultaneously provides higher values of both sensitivity and accuracy which ...

2009-02-21

191

Observation of Spontaneous Brillouin Cooling  

CERN Document Server

While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but also for the first time, a Brillouin cooling ...

2011-01-01

192

Electron scattering from atoms in the presence of a laser field. II  

Science.gov (United States)

In the first paper of this series a formal theory of atomic scattering of electrons in the presence of an intense electromagnetic field was given. Cross sections, near the forward direction, between atomic states (modified by the laser) were obtained. However, it was assumed that the atom could not emit spontaneous radiation. In this paper the effect of spontaneous radiation is included, and it is shown that in most cases the measured cross section will be a weighted average of the two different cross sections starting from the two different initial states which are those atomic states resonantly linked by the laser. The Born approximation for the scattering is obtained, and it is shown that for the simplest description of the spontaneous radiation field the effect of the laser on the cross sections is simply to multiply them by a factor which depends upon the laser detuning. (AIP)

1976-10-01

193

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

194

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

195

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

196

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li{sub 2}S-SiS{sub 2}-Li{sub 3}PO{sub 4} Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

197

Structural Change Accompanying Crystallization in the Lithium Ion Conductive Li[sub 2]S-SiS[sub 2]-Li[sub 3]PO[sub 4] Oxysulfide Glasses  

Energy Technology Data Exchange (ETDEWEB)

The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)

1999-02-01

198

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...

2006-08-30

199

Simulating the X-ray Forest  

CERN Document Server

Numerical simulations predict that a large number of baryons reside in intergalactic space at temperatures between 10^5-10^7 K. Highly-ionized metals, such as O VII and O VIII, are good tracers of this ``warm-hot intergalactic medium'', or WHIM. For collisionally-ionized gas, the ionization fraction of each ion peaks at some particular temperature (``peak temperatures''), so different ions can therefore trace the IGM at different temperatures. We performed a hydrodynamic simulation to study the metal distributions in the IGM. We then draw random lines-of-sight across the simulated region and synthesize resonance absorption line spectra in a similar way to simulating the Ly-alpha forest. By studying the distribution functions of H- and He-like O, Si and Fe in a collisionally-ionized IGM and comparing with semi-analytic results based on the Press-Schechter formalism, we find: (1) ions with higher peak temperatures (for instance, Fe XXVI) tend to concentrate around ...

2001-01-01

200

Relationships between the state of oxidation and catalytic activity of chromium, molybdenum and tungsten in hydrocarbon reactions; Beziehungen zwischen Oxidationszustand und katalytischer Aktivitaet von Chrom, Molybdaen und Wolfram in Kohlenwasserstoffreaktionen  

Energy Technology Data Exchange (ETDEWEB)

The knowledge shown in this work of the relationships between the oxidation stage of chromium, molybdenum and tungsten and their catalytic activity in some hydrocarbon reactions was achieved by the combination of separate investigations of reduction properties and the catalytic activity of the catalysts concerned. To characterize the electronic state of the reduced surfaces, X-ray photo-electronic spectroscopy was mainly used, supplemented by electron spin resonance. The catalyst activity was measured in conventional apparatus (flow, pulse and gradient-free reactors). (orig.) [Deutsch] Die in dieser Arbeit dargestellten Erkenntnisse ueber die Zusammenhaenge zwischen der Oxidationsstufe von Chrom, Molybdaen und Wolfram und ihrer katalytischen Aktivitaet in einigen Kohlenwasserstoffreaktionen wurden durch die Kombination getrennter Untersuchungen ueber Reduktionseigenschaften und katalytische Aktivitaet der betreffenden Katalysatoren erzielt. ...

1992-02-17

201

Novel non-discoid chiral copper(II)-salen type [N2O2] donor Schiff base complexes with a cyclohexane diamine spacer: synthesis, electrochemistry, columnar mesomorphism and DFT study  

British Library Electronic Table of Contents (United Kingdom)

A series of new non-discoid chiral copper(ii)-salen type complexes, [Cu((4-CnH2n+1O)2salen)], n = 14, 16, 18 and salen = N,N'-cyclohexane bis (salicylideneiminato), containing 4-substituted alkoxy tails in the side aromatic rings and a cyclohexane spacer, have been prepared and their mesogenic properties investigated. The compounds were characterised by Fourier transform infra-red spectroscopy, 1H and 13C nuclear magnetic resonance spectroscopy, UV-vis spectroscopy and fast atom bombardment mass spectrometry. Mesomorphic properties of these compounds were studied by polarising optical microscopy, differential scanning calorimetry and X-ray diffraction (XRD). The ligands are non-mesogenic but the complexes exhibited enantiotropic rectangular columnar mesophases (Colr) with extended temperat...

2011-01-01

202

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m ...

2003-06-01

203

WITNESSING THE KEY EARLY PHASE OF QUASAR EVOLUTION: AN OBSCURED ACTIVE GALACTIC NUCLEUS PAIR IN THE INTERACTING GALAXY IRAS 20210+1121  

International Nuclear Information System (INIS)

We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the theoretical models of ...

2010-10-20

204

Transitions between distinct compaction regimes in complexes of multivalent cationic lipids and DNA  

CERN Document Server

We use X-ray scattering and molecular simulations to investigate the structural properties of complexes of multivalent cationic lipids and DNA molecules. At low mole fraction of neutral lipids (NLs), $\\Phi_{\\rm NL}$, the complexes show dramatic DNA compaction down to essentially close packed DNA arrays with a DNA interaxial spacing $d_{\\rm DNA}=25\\AA$. A gradual increase in $\\Phi_{\\rm NL}$ does not lead to a continuous increase in $d_{\\rm DNA}$ as observed for DNA complexes of monovalent cationic lipids (CLs). Instead, distinct spacing regimes exist, with sharp transitions between them. Three packing states have been identified: (i) close packed, (ii) condensed, but not close packed, with $d_{\\rm DNA}=27-28\\AA$, and (iii) an expanded state, where $d_{\\rm DNA}$ increases gradually with $\\Phi_{\\rm NL}$. Based on our experimental and computational results, we conclude that the DNA condensation is mediated by the multivalent cationic ...

2008-01-01

205

Surface Topography of 'Hotspot' Regions from a Single Cell SRF Cavity  

Energy Technology Data Exchange (ETDEWEB)

Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while 3D profilometry gave information on the depth and size ...

2009-05-01

206

Structural and vibrational studies of LiNi{sub 1-y}Co{sub y}VO{sub 4} (0{<=}y{<=}1) cathodes materials for Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

The structure and vibrational properties of high voltage cathode materials, namely LiNi{sub 1-y}CO{sub y}VO{sub 4} solid solution with (0{<=}y{<=}1), have been studied using X-ray diffraction, Raman scattering and FTIR measurements. Rietveld refinements show that LiNi{sub 1-y}Co{sub y}VO{sub 4} vanadates belong to the inverse spinel structure with Fd3m(O{sup 7}{sub h}) space group. Analysis of Raman spectra has been carried out in the molecular approximation using a local environment model including VO{sub 4} tetrahedra, (Ni, Co)O{sub 6} and LiO{sub 6} octahedra as vibrational local units. (orig.)

2000-05-15

207

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...

1986-01-01

208

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)

2003-06-01

209

Ising model for phase separation in alloys with anisotropic elastic interaction. 2: A computer experiment  

Energy Technology Data Exchange (ETDEWEB)

When a metallic alloy is quenched into a miscibility gap, a mixture of two phases develops, whose domain structure then coarsens because of the interfacial energy between the two phases. This spatial arrangement of the domains and the rate at which they evolve may be strongly influenced by elastic interactions. In a recent paper, the authors described a method for simulating the effect of anisotropic elastic interactions in a two-dimensional Ising model of a cubic alloy, using Kawasaki dynamics with the elastic interactions represented by a long-range two-body interaction potential. Here they present the results of such simulations at various temperatures, alloy compositions and misfits (by misfit they mean the difference in size between the two kinds of atom), exhibiting snapshots both of the microscopic configurations (corresponding to experimental measurements using transmission electron microscopy) and of their squared Fourier transforms (corresponding to measurements using ...

1996-08-01

210

Effect of gamma irradiation on tensile properties of low molecular weight polyethylene samples  

International Nuclear Information System (INIS)

Three high density polyethylene (PE) samples of different origins, with weight average molar masses ranging from 38 to 63 kg mol"-"1 and displaying a semi-ductile behavior with strain at break ?_R values of the order of 100-140%, were gamma irradiated under nitrogen for doses up to 33.3 kGy. Steric exclusion chromatography and rheometry allowed to quantify the crosslink density X. This later reached values ranging from 4.6 to 9.0x10"-"3 mol kg"-"1, i.e. situated below the gelation point. Differential calorimetry, density measurement and small angle X-rays scattering showed the absence of significant changes in the crystalline morphology, especially lamellar dimensions. Tensile testing revealed an unexpected trend towards brittle regime of fracture while yield stress increases significantly at low doses. It appeared that branching disfavors cavitation during yielding, but this effect is not favorable to ductility.

2011-08-01

211

Strong WW scattering at photon linear colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma}{yields}ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson. ((orig.)).

1995-02-01

212

Strong WW scattering at photon linear colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the possibility of observing strong interactions of longitudinally polarized weak vector bosons in the process {gamma}{gamma} {yields} ZZ at a photon linear collider. We make use of polarization of the photon beams and cuts on the decay products of the Z bosons to enhance the signal relative to the background of transversely polarized ZZ pairs. We find that the background overwhelms the signal unless there are strong resonant effects, as for instance from a technicolor analogue of the hadronic f{sub 2}(1270) meson.

1994-06-01

213

Quasiparticle transport equation with collision delay. I. Phenomenological approach  

International Nuclear Information System (INIS)

For a system of noninteracting electrons scattered by resonant levels of neutral impurities, we show that virial and quasiparticle corrections have nearly equal magnitudes. We propose a modification of the Boltzmann equation that includes quasiparticle and virial corrections and discuss their interplay on a dielectric function. copyright 1997 The American Physical Society.

214

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

215

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

216

Observability of complex ghosts and tachyons  

International Nuclear Information System (INIS)

The complex ghost introduced previously by the present author is studied from a standpoint whether its effects are observable by experiments or not. According to the theory of complex ghost the scattering cross section of two real particles shows some particular properties. It has a kind of resonance peak at a certain energy which does not conform to the Breit-Wigner formula. It has also a peak for a certain energy transfer, if there exist tachyons. The tachyon is a kind of ghost and is allowed to exist in the theory. Using these properties the complex ghosts are expected to be detected by experiments. The recently observed resonance psi(3.1) is supposed to be the complex ghost of photon, since they have the same quantum numbers. If it is assumed, some properties of the resonance known by experiments are explained naturally to a certain extent. Along the same line it is not unnatural to expect that the ...

217

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

218

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

219

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

220

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

221

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

222

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

223

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

224

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

225

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

226

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

227

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

228

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

229

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...

2009-07-01

230

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

231

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

232

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

233

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

234

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

235

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

236

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

237

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

238

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

241

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

242

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

243
244

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

245

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

246

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

247

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

249

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

250

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

251

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

252

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

254

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

255

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

256

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

257

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

258

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

259

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

260

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

261

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

262

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

263

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

264

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

265

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

266

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

267

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

268

Isoscalar giant dipole resonance for several nuclei with A {>=} 90  

Energy Technology Data Exchange (ETDEWEB)

The giant resonance region in several nuclei in A {>=} 90 have been re-measured using 240 MeV {alpha} particle scattering with a detector provides that both horizontal and vertical angles. Slice analyses with multipole fits were performed and strength due to both low and high energy components of the isoscalar giant dipole resonance (ISGDR) was identified. E1 strengths for the high energy component corresponding to 70{+-}15%,68{+-}15% and 67{+-}14% of the isoscalar E1 energy-weighted sum rule were identified, with centroid energies of 26.3{+-}0.6 MeV, 24.7{+-}0.6 MeV and 21.7{+-}0.6 MeV for {sup 90}Zr, {sup 144}Sm and {sup 208}Pb, respectively. The centroid of the high energy component of the strength distribution is in closer agreement with the microscopic prediction generated using compressibilities obtained from the isoscalar giant monopole resonance data.

2004-02-09

269

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

270

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

271

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

272

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

273

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

274

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

275

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

276

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

277

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

278

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

279

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

280

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

281

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

282

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

283

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

284

Isoscalar giant dipole resonance in {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb excited by 240 MeV {alpha} particle scattering  

Energy Technology Data Exchange (ETDEWEB)

The giant resonance regions of {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb were investigated using 240 MeV {alpha} particle scattering at small angles including 0 deg. E1 strengths corresponding to 91{+-}11%, 89{+-}10%, 105{+-}12% and 95{+-}13% of the isoscalar E1 energy-weighted sum rule were identified between 18{<=}E{sub x}{<=}31 MeV, 16{<=}E{sub x}{<=}30 MeV, 15{<=}E{sub x}{<=}27 MeV and 15{<=}E{sub x}{<=}25 MeV with centroid energies of 24.8{+-}0.4 MeV, 22.5{+-}0.3 MeV, 21.6{+-}0.3 MeV and 19.3{+-}0.3 MeV and rms widths of 3.2{+-}0.2 MeV, 3.5{+-}0.2 MeV, 3.2{+-}0.2 MeV and 2.5{+-}0.2 MeV for {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb, respectively. Parameters obtained for the isoscalar giant monopole resonance, isoscalar giant quadrupole resonance and high energy octupole resonance are in agreement with ...

1999-03-29

285

Isoscalar giant dipole resonance in "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb excited by 240 MeV #alpha# particle scattering  

International Nuclear Information System (INIS)

The giant resonance regions of "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb were investigated using 240 MeV #alpha# particle scattering at small angles including 0 deg. E1 strengths corresponding to 91#+-#11%, 89#+-#10%, 105#+-#12% and 95#+-#13% of the isoscalar E1 energy-weighted sum rule were identified between 18#<=#E_x#<=#31 MeV, 16#<=#E_x#<=#30 MeV, 15#<=#E_x#<=#27 MeV and 15#<=#E_x#<=#25 MeV with centroid energies of 24.8#+-#0.4 MeV, 22.5#+-#0.3 MeV, 21.6#+-#0.3 MeV and 19.3#+-#0.3 MeV and rms widths of 3.2#+-#0.2 MeV, 3.5#+-#0.2 MeV, 3.2#+-#0.2 MeV and 2.5#+-#0.2 MeV for "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb, respectively. Parameters obtained for the isoscalar giant monopole resonance, isoscalar giant quadrupole resonance and high energy octupole resonance are in agreement with accepted values.

1999-03-29

286

Solid-state NMR and XRD study of #alpha#-SiAlON powders prepared by combustion synthesis  

International Nuclear Information System (INIS)

"2"7Al and "2"9Si solid-state NMR spectra and X-ray diffraction (XRD) patterns were obtained for #alpha#-SiAlON powders prepared by combustion synthesis, according to which the phase transformation and structure evolution of #alpha#-SiAlON were studied. It was found that in #alpha#-SiAlON "2"9Si chemical shift values (-48 < #delta# _S_i < -47) were close to those in #beta#-Si_3N_4 and #alpha#-Si_3N_4, indicating that Si atoms kept SiN_4 coordination to a large extent in #alpha#-SiAlON despite the presence of O atoms. Dissimilarly, "2"7Al chemical shift values in #alpha#-SiAlON deviated clearly from that corresponding to AlN_4 coordination (#delta# _A_l #approx# 112) and occurred in a range from #delta# _A_l 95.5 to 99.9, which should be assigned to tetrahedral AlO _xN_4_-_x (0 #<=# x #<=# 4) coordination. The broadening effect of AlO _xN_4_-_x peaks was noticed, which was suggested to induced by slight dispersion of #alpha#-SiAlON compositions. "2"7Al ...

2007-07-31

287

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

288

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

Energy Technology Data Exchange (ETDEWEB)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He/sup -/ states.

1984-03-01

289

Resonant neutralization of He ions into excited states at Cu(110) and Ni(110) surfaces  

International Nuclear Information System (INIS)

He ions incident at grazing angles on Cu(110) and Ni(110) surfaces are neutralised into triplet and singlet states, of which the 3p, 3d and 4d upper states are accessible to optical spectroscopy. In the energy range from 500 eV to 15 keV no significant energy dependence of the relative intensities of singlet and triplet lines was observed for scattering on Cu(110). The intensities from Ni(110) are higher and the singlet to triplet intensity ratio of the 3d to 2p transition is about 6% smaller than that from Cu(110). The results can be explained well by assuming resonant charge capture into excited He and intermediate formation of negative He"- states. (orig.).

1983-07-01

290

Characteristics of wave-particle interaction in a hydrogen plasma  

International Nuclear Information System (INIS)

We study the characteristics of cyclotron wave-particle interaction in a typical hydrogen plasma. The numerical calculations of minimum resonant energy Emin, resonant wave frequency ?, and pitch angle diffusion coefficient D?? for interactions between R-mode/L-mode and electrons/protons are presented. It is found that Emin decreases with ? for R-mode/electron, L-mode/proton and L-mode/electron interactions, but increase with ? for R-mode/proton interaction. It is shown that both R-mode and L-mode waves can efficiently scatter energetic (10 keV-100 keV) electrons and protons and cause precipitation loss at L=4, indicating that perhaps wave-particle interaction is a serious candidate for the ring current decay. (authors)

2008-09-01

291

Correlating microstructure and thermal transport of irradiated SiC  

International Nuclear Information System (INIS)

Full text of publication follows: The effect of neutron irradiation on the thermal conductivity of silicon carbide can be dramatic depending on the irradiation temperature and fluence the material is subjected to, and may be a critical factor defining it's use in fusion systems. Historically there have been several papers describing the effect of neutron irradiation on thermal conductivity degradation of SiC, predominately in the low to intermediate temperature ranges. Practically all of this work has been at temperatures lower than the application temperature for SiC being considered by the conceptual fusion reactors. This paper provides new data on the thermal conductivity of high quality CVD silicon carbide irradiated in a range of doses and temperature spanning the proposed fusion reactor temperature range. Specifically, an irradiation was carried out from fractions milli-dpa to approximately 8 dpa in the HFIR with irradiation temperatures ranging from 80-1600 deg. C. Results of ...

2007-12-10

292

Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis  

International Nuclear Information System (INIS)

Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. ...

293

Excitation cross sections for the ns "2S#->#np "2P resonance transitions in Mg"+ (n=3) and Zn"+ (n=4) using electron-energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Electron-excitation cross sections are reported for the 3s "2S#->#3p "2P(h,k) resonance transition in Mg"+ at energies from threshold (4.43 eV) to approximately 9 times threshold (40.0 eV). The electron-energy-loss merged-beams technique used in these measurements is described in detail. In addition, the method of separating contributions of the elastically scattered (Coulomb) and the inelastically scattered electrons in the present Mg"+ case and previously reported Zn"+ results [Phys. Rev. Lett. 67, 30 (1991)] is described. Comparisons in the experimental energy range are made for Mg"+ with the two five-state close-coupling theoretical calculations carried out herein, and with other published close-coupling, distorted-wave, and semiempirical calculations. The present Mg"+ cross sections and Zn"+ cross sections from earlier measurements are tabulated.

294

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...

2003-11-01

295

Virtual and resonance levels in screened Coulomb potentials  

International Nuclear Information System (INIS)

Two methods for computation of real, virtual and quasistationary energy eigenvalues are considered: summation of divergent perturbation series, solution of integral equations for t matrix on physical and nonphysical sheets of energy. The results of energy computation for s-, p- and d-states in potentials of a screened Coulomb type are presented. It is shown on an example of the Yukawa potential that the energy eigenvalues given by both these methods coincide with high precision. As an illustration the positions of real (deuteron) and virtual (singlet deuteron) poles of the np-scattering amplitude are calculated. For Yukawa type potentials the new theorem of symmetry for bound and virtual levels is discussed.

2003-09-01

296

Spin Duality on the Neutron (^3He)  

Energy Technology Data Exchange (ETDEWEB)

Thomas Jefferson National Accelerator Facility experiment E01-012 measured the 3He spin structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0 < Q2 < 4.0 (GeV/c)2. Our date, when compared with existing deep inelastic scattering data, can be used to test quark-hadron duality in g1 and A1 for 3He and the neutron. Preliminary results for A{sub 1}{sup {sup 3}He} are presented, as well as some details about the experiment.

2007-02-01

297

Rocket borne solar eclipse experiment to measure the temperature structure of the solar corona via lyman-. cap alpha. line profile observations  

Energy Technology Data Exchange (ETDEWEB)

A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.

1981-01-01

298

Numerical study of Cosmic Ray Diffusion in MHD turbulence  

CERN Document Server

We study diffusion of Cosmic Rays (CRs) in turbulent magnetic fields using test particle simulations. Electromagnetic fields are produced in direct numerical MHD simulations of turbulence and used as an input for particle tracing, particle feedback on turbulence being ignored. Statistical transport coefficients from the test particle runs are compared with earlier analytical predictions. We find qualitative correspondence between them in various aspects of CR diffusion. In the incompressible case, that we consider in this paper, the dominant scattering mechanism occurs to be the non-resonant mirror interactions with the slow-mode perturbations. Perpendicular transport roughly agrees with being produced by magnetic field wandering.

2010-01-01

299

Local lattice structure, crystal field and energy level patterns in CsCdBr_3:Tm"3"+ crystals  

International Nuclear Information System (INIS)

In CsCdBr_3, Tm"3"+ substitutes for Cd"2"+. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm"3"+ ions. (orig.)

1998-07-24

300

Analysis of superconducting oxide by 7 MeV alpha particle backscattering analysis  

International Nuclear Information System (INIS)

High energy ion backscattering analysis in combination with recently-developed resonance scattering analysis is described, with a stress on precise and quantitative oxygen analysis and its successful application to the characterization and quality estimation of high T_c oxide superconductors. Particularly, the present status of high energy ion backscattering analysis, the review of analytical results for YBa_2Cu_3O_7 _- _x, the estimation of composition and crystalline quality of (La_1 _- _xSr_x)_2CuO_4 by 7 MeV alpha particle backscattering analysis are described.

1989-04-24

301

Global optical model potentials for symmetrical lithium systems: "6Li+"6Li, "7Li+"7Li at E_l_a_b = 5-40 MeV  

International Nuclear Information System (INIS)

Angular distributions of "6Li+"6Li elastic scattering were measured for E_l_a_b=5-40 MeV. An optical model analysis of these data together with older data of "7Li+"7Li elastic scattering taken at E_l_a_b = 8-17 MeV was performed with the aim to search for a ''global'' OM potential which describes elastic scattering in both Li-Li systems in a broad energy range. Both surface and volume absorbing potentials can be found which fulfill this requirement if a linear energy dependence is assumed of the depths of the real as well as the imaginary potential. These depths, if fitted to individual angular distributions, are found to vary in a correlated manner with the beam energy. This is taken as indication of strong coupling between elastic, inelastic, and reaction channels. This is corroborated by the existence of resonances in reaction channels at these energies where the potential depths are most ...

302

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

303

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

304

Standard samples for X-ray radiometric analysis of substance composition  

International Nuclear Information System (INIS)

Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.

305

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

306

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

307

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

308

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

309

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

310

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

311

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

312

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

313

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

314

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

315

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

316

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

317

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

318

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

319

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

320

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

322

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

323

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

324

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

326

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

327

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

328

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

331

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

332

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

333

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

334

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

335

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

336

On the Z-dependence of K#alpha#_1/K#beta#_1 X-ray intensity ratio  

International Nuclear Information System (INIS)

1976. Germany Ramaswamy, MK Birla Inst. of Tech. and Science, Pilani

1976-03-29

337

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

338

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

339

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

340

Koji Mukai's Bibliography - Astrophysics Science Division Staff ...  

Science.gov (United States)

Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...

341

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

342

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

344

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

345

Future instrumentation for the study of the Warm-Hot Intergalactic Medium  

CERN Document Server

We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.

2008-01-01

346

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

347

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

348

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

349

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

350

Density Gradients for Isolation of Mononuclear Blood Cells for ...  

Science.gov (United States)

... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...

2011-05-15

353

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

354

Nanoparticle arrays formed by spatial compartmentalization in a complex fluid.  

Energy Technology Data Exchange (ETDEWEB)

A mesoscopically ordered lamellar gel phase of a polymer-grafted, lipid-based complex fluid is used as a scaffolding to spatially organize inorganic nanoparticles. The complex fluid provides both a highly anisotropic environment and a segregated aqueous and organic domains in which inorganic nanoparticles can be selectively placed by tailoring their size and surface characteristics. Three types of silver nanoparticles -- underivatized, surfactant-stabilized, and dodecanthiol-derivatized -- were evaluated. Comparison of the surface plasmon resonance of the various silver particles dispersed in conventional solvents to those contained within the complex fluid was used to determine the region of spatial localization in the lamellar gel phase. Silver particles rendered hydrophobic by capping with an alkane thiol insert into the hydrocarbon bilayer region. Surfactant-stabilized and underivatized silver nanoparticles reside in the aqueous channels, with the latter ...

2001-03-14

355

Intrinsic magnetism in Fe doped SnO2 nanoparticles  

International Nuclear Information System (INIS)

Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples is isolated rhombic ...

2011-01-01

356

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with ...

1991-12-01

357

Enhanced Activity of Nanocrystalline Zeolites for Selective Catalytic Reduction of NOx  

Energy Technology Data Exchange (ETDEWEB)

Nanocrystalline zeolites with discrete crystal sizes of less than 100 nm have different properties relative to zeolites with larger crystal sizes. Nanocrystalline zeolites have improved mass transfer properties and very large internal and external surface areas that can be exploited for many different applications. The additional external surface active sites and the improved mass transfer properties of nanocrystalline zeolites offer significant advantages for selective catalytic reduction (SCR) catalysis with ammonia as a reductant in coal-fired power plants relative to current zeolite based SCR catalysts. Nanocrystalline NaY was synthesized with a crystal size of 15-20 nm and was thoroughly characterized using x-ray diffraction, electron paramagnetic resonance spectroscopy, nitrogen adsorption isotherms and Fourier Transform Infrared (FT-IR) spectroscopy. Copper ions were exchanged into nanocrystalline NaY to increase the catalytic activity. ...

2006-12-31

358

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

359

Solution processable fluorenyl hexa-peri-hexabenzocoronenes in organic field-effect transistors and solar cells  

Energy Technology Data Exchange (ETDEWEB)

The organization of organic semiconductor molecules in the active layer of organic electronic devices has important consequences to overall device performance. This is due to the fact that molecular organization directly affects charge carrier mobility of the material. Organic field-effect transistor (OFET) performance is driven by high charge carrier mobility while bulk heterojunction (BHJ) solar cells require balanced hole and electron transport. By investigating the properties and device performance of three structural variations of the fluorenyl hexa-peri-hexabenzocoronene (FHBC) material, the importance of molecular organization to device performance was highlighted. It is clear from {sup 1}H NMR and 2D wide-angle X-ray scattering (2D WAXS) experiments that the sterically demanding 9,9-dioctylfluorene groups are preventing {pi}-{pi} intermolecular contact in the hexakis-substituted FHBC 4. For bis-substituted FHBC compounds 5 and 6, ...

2010-03-24

360

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from ...

1981-01-01

361

First-principles nonlocal-pseudopotential approach in the density-functional formalism. II. Application to electronic and structural properties of solids  

International Nuclear Information System (INIS)

We apply our previously developed first-principles nonlocal pseudopotentials (obtained for all atoms of rows 1--5 in the Periodic Table) to study self-consistently the electronic structure of Si and Ge and the transition metals Mo and W. For Si and Ge we find that the first-principles pseudopotentials yield valence-band states in good agreement with the empirically adjusted pseudopotential and photoemission data, whereas the low conduction-band states appear to be consistently lower in energy due apparently to incomplete cancellation of the self-interaction effects. The calculated x-ray scattering factors (obtained by core orthogonalization of the pseudo-wave-functions) are in excellent agreement with experiment. The self-consistent valence charge density shows a distinct elongation of the covalent bond along the internuclear axis, in good agreement with the experimentally synthesized density. The systematic deviations of the empirical ...

362

Decay of H{sub 2}{sup -} anions in solid parahydrogen by quantum tunneling: observations of electron bubbles  

Energy Technology Data Exchange (ETDEWEB)

Decay mechanism of H{sub 2}{sup -} anions produced by {gamma}-ray or X-ray radiolysis of solid para-H{sub 2} (p-H{sub 2}) has been studied using high-resolution ESR spectroscopy in the temperature range between 2.7-6.6 K. The results can be summarized as follows; First, the decay rate constant of the H{sub 2}{sup -} anion is not proportional to initial yields of reactive species such as H radical and cation but proportional to concentrations of HD and D{sub 2} impurities in p-H{sub 2}. Second, ESR spectra assigned as electron bubbles were observed in solid p-H{sub 2} containing large amount of HD or D{sub 2} (11 mol %), while they were not observed in pure solid p-H{sub 2}. Third, the decay rate constant of the H{sub 2}{sup -} anion increases with the decrease in temperature between 2.7-5 K, while it decreases with the decrease between 5-6.6 K. Fourth, the decay of the H{sub 2}{sup -} anion is suppressed by addition of ortho-H{sub 2} (o-H{sub 2}) impurity. The ...

1998-02-01

363

Comparative studies on titanium and tantalum oxides thin film structures for laser mirrors, deposited by ion assisted gun  

International Nuclear Information System (INIS)

For obtaining radiation less damagable laser mirrors, a preliminary optimization of film fabrication suitable for the analysis of laser damage mechanism has been done as the first step. Here, the optimization requires not only the stable fabrication process but also the ideal film structure i.e., the amorphous and smooth film structure simultaneously, eliminating latently unwanted secondary effects such as light scattering during laser damage test. For this purpose, we adopted the ion assisted deposition (IAD) method and modified the deposition conditions for titanium and tantalum oxide films, both of which compose typical high index layers, and where SiO_2 layers are also chosen as low index layers because of their amorphous and smooth nature, in alternative multilayer laser mirrors. Surface and cross sectional film structures and film crystallinity are compared and characterized, using a high resolution SEM and a x-ray diffractometer, ...

1996-10-07

364

Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV  

Energy Technology Data Exchange (ETDEWEB)

The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical ...

2009-09-01

365

Re-evaluation of {sup 58}Ni and {sup 60}Ni resonance parameters in the neutron energy range thermal to 800 keV  

Energy Technology Data Exchange (ETDEWEB)

The previous {sup 58}Ni and {sup 60}Ni set of resonance parameters (Endf/B7.O, Jeff-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C.M. Perey et al. The present results were obtained by adding to the SAMMY experimental database the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator and very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to ...

2009-07-01

366

Isobaric analog resonances in "8"9Y  

International Nuclear Information System (INIS)

Three resonances at the proton energies 7.0, 7.08, and 7.53 MeV on the target "8"8Sr were chosen to investigate the possibility of determining the amplitudes of the weak coupling experimentally. The corresponding "8"9Sr levels under investigation were 1.93 MeV ("5/_2"+), 2.00 MeV ("3/_2"+), and 2.46 MeV ("3/_2"+). Angular distributions were measured on resonance at 7.0, 7.08, and 7.53 MeV from proton inelastic scattering to the 1.84 MeV (2"+) state of "8"8Sr for differential cross section, analyzing power, spin-flip probability, and spin-flip asymmetry. A polarized beam of protons was used to obtain the analyzing power. The spin-flip probability was obtained from the coincidence of the prompt gamma rays from the (p,p'#gamma#) reaction with the scattered protons. With the polarized beam, the gamma coincidence technique was further used to obtain a spin-flip asymmetry measurement. From these measurements, ...

367

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

368

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

369

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

370

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

371

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

372

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

373

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

374

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

375

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

376

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

377

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

378

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

379

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

380

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

381

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

382

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell ...

383

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

384

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

385

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

386

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

387

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

388

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

389

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

390

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

391

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

392

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

393

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

394

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

395

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

396

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

397

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

398

Comments on possible preferential order-disorder in A-15 compounds based upon Nb  

International Nuclear Information System (INIS)

The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).

399

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

400

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

401

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

402

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

403

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

404

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

405

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

406

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

407

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

408

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

409

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

410

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...

2000-08-01

411

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days ...

2001-01-01

412

X-ray and HeI 1.0830 mu emission from protostellar jets  

CERN Document Server

Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical models of intermediately fast (> 500 - ...

2006-01-01

413

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power law model with ...

2010-01-01

414

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the ...

2005-01-01

415

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an ...

2008-02-01

416

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

417

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

418

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with ...

2011-01-01

419

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

420

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

Energy Technology Data Exchange (ETDEWEB)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray intensity ratio was found to ...

1983-09-01

421

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

International Nuclear Information System (INIS)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ratio was found to be an ...

1982-10-01

422

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

423

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of ...

2008-01-01

424

Comparison on the growth of oxide films formed in alloy 800 and alloy 600 in an aqueous medium at high temperature  

International Nuclear Information System (INIS)

Alloy 800 and Alloy 600 are well known for their resistance to corrosion in an aqueous medium at high pressure and temperature, for which they have been widely used for more than 3 decades in different structural components of water refrigerated nuclear reactors, especially as material for the steam generator tubes (SG) in these nuclear plants. The SG tubes in the Atucha I and Embalse Nuclear Plants are made with Alloy 800. The speed of corrosion of these materials in a reactor's refrigerant medium, while very small is perfectly measurable and can be described by parabolic or logarithmic type kinetics. In other words this speed is high in the first states of growth during the formation of a protective oxide film but then drops to almost stationary values. One characteristic of these films is the formation of a double layer (or duplex): i) an internal adhering layer, of approximately constant thickness, formed by small microcrystals (#<=#0.05 mm), ii) a less adhering external one, ...

2006-12-01

425

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

426

TeV gamma-rays from the Northern sky pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We estimate the TeV {gamma}-ray fluxes expected from the population of young pulsars in terms of the self-consistent time-dependent hadronic-leptonic model for the high-energy processes inside the pulsar wind nebulae (PWNe). This radiation model is based on the hypothesis of Arons and collaborators who postulate that leptons are accelerated inside the nebulae as a result of resonant scattering on heavy nuclei, which in turn are accelerated in the pulsar wind region or the pulsar inner magnetosphere. Our aim is to find out which PWNe on the northern hemisphere are the best candidates for detection at energies above 60 GeV and 200 GeV by the next generation of low-threshold Cherenkov telescopes.

2005-12-01

427

Local lattice structure, crystal field and energy level patterns in CsCdBr{sub 3}:Tm{sup 3+} crystals  

Energy Technology Data Exchange (ETDEWEB)

In CsCdBr{sub 3}, Tm{sup 3+} substitutes for Cd{sup 2+}. It predominately forms symmetric dimer centers and single-ion centers, both of trigonal symmetry. The energy level schemes of both centers were determined by EPR and site-selective laser spectroscopy. To describe the spectra term dependent crystal-field parameters were deduced on the basis of a microscopic model taking into account the local lattice deformation induced by the impurity centers and the quasi-resonant virtual scattering of intrinsic lattice excitations by the Tm{sup 3+} ions. (orig.) 22 refs.

1998-07-24

428

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab Nebula.

2005-08-01

429

Absolute electron scattering cross sections for the "2S#->#"2P transition in Zn"+ using energy-loss and merged-beams methods  

International Nuclear Information System (INIS)

Using the electron energy-loss method in a merged electron-ion beams geometry absolute, cascade-free excitation cross sections have been measured for the resonance "2S#->#"2P transition in Zn"+. Measurements were carried out at electron energies of below threshold (threshold at 6.011 eV) to 40 eV. Results are in very good agreement with close-coupling calculations and, away from threshold, lie below absolute line-emission cross sections which include effects of cascade into the "2P state from higher levels.

1991-02-20

430

A neutrino-nucleon interaction generator for the FLUKA Monte Carlo code  

CERN Document Server

Event generators that handle neutrino-nucleon interaction have been developed for the FLUKA code [1]. In earlier FLUKA versions only quasi-elastic (QEL) interactions were included, and the code relied on external event generators for the resonance (RES) and deep inelastic scattering (DIS). The new DIS+RES event generator is fully integrated in FLUKA and uses the same hadronization routines as those used for simulating hadron-nucleon interactions. Nuclear effects in neutrino-nucleus interactions are simulated within the same framework as in the FLUKA hadron-nucleus interaction model (PEANUT), thus profiting from its detailed physics modelling and longstanding benchmarking. The generators are available in the standard FLUKA distribution. They are presently under development and several improvements are planned to be implemented. The physics relevant to the neutrino-nucleon interactions and the results of comparisons with experimental data are ...

2010-01-01

431

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...

1981-01-01

432

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

433

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

434

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

435

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

436

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

437

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

438

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

439

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

440

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

441

Studies of L x-rays from 64 MeV iodine projectiles in collision with gas targets  

International Nuclear Information System (INIS)

We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)

1997-11-17

442

Simulation Studies of the X-Ray Free-Electron Laser Oscillator  

Energy Technology Data Exchange (ETDEWEB)

Simulations of the x-ray free-electron laser (FEL) oscillator are presented that include transverse effects and realistic Bragg crystal properties with the two-dimensional code GINGER. In the present cases considered the radiation divergence is much narrower than the crystal acceptance, and the numerical algorithm can be simplified by ignoring the finite angular bandwidth of the crystal. In this regime GINGER shows that the saturated x-ray pulses have 109 photons and are nearly Fourier-limited with peak powers in excess of 1 MW. Wealso include preliminary results for a four-mirror cavity that can be tuned in wavelength over a few percent, with future plans to incorporate the full transverse response of the Bragg crystals into GINGER to more accurately model this tunable source.

2009-08-14

443

Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+  

British Library Electronic Table of Contents (United Kingdom)

The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...

2009-01-01

444

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

445

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

446

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

447

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

448

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

449

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...

1981-10-01

450

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

451

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

452

Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.

2009-12-11

453

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

454

Influence of alloying effect on X-ray fluorescence parameters of Co and Cu in CoCuAg alloy films  

British Library Electronic Table of Contents (United Kingdom)

In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.

2009-01-01

455

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

456

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

457

Exploring the Physics of Type Ia Supernovae Through the X-ray Spectra of their Remnants  

CERN Document Server

We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-ray emission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.

2005-01-01

458

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

459

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

460

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

461

Cluster Geometry & Inclinations from Deprojection Uncertainties  

CERN Document Server

{The determination of cluster masses is a complex problem that would be aided by information about the cluster shape and orientation (along the line-of-sight).} {It is in this context, that we have developed a scheme for identifying the intrinsic morphology and inclination of a cluster, by looking for the signature of the true cluster characteristics in the inter-comparison of the different deprojected emissivity profiles (that all project to the same X-ray brightness distribution) and by using SZe data when available.} {We deproject the cluster X-ray surface brightness profile under the assumptions of four different geometry and inclination configurations for the observed system; these 4 configurations correspond to four extreme geometry+inclination scenarios. The deprojection in question is performed by the non-parametric algorithm DOPING. The formalism is tested with model systems and then is applied to a sample of 24 clusters. While the ...

2008-01-01

462

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

463

Association of brain cancer with dental x-rays and occupation in Missouri  

International Nuclear Information System (INIS)

This investigation of a brain cancer cluster in Missouri used two approaches to investigate associations with potential risk factors. In a case-control study in a rural town, we interviewed surrogates of cases and controls about potential risk factors. We found a statistically significant positive association of brain cancer with reported exposure to dental x-rays. Occupation was not associated with the cluster in the rural town. In a standardized proportional mortality study for the state of Missouri, we calculated the observed and expected proportion of brain cancers by occupation and industry in Missouri decedents. We found that motor vehicle manufacturers, beauty shop workers, managers and administrators, elementary school teachers, and hairdressers and cosmetologists had significantly elevated proportions of brain cancer. Brain tumors are inconsistently associated with occupation in the literature. Further study of brain cancer etiology with respect to dental ...

1991-01-01

464

An X-ray photoelectron spectroscopic study of B-N-Ti system  

International Nuclear Information System (INIS)

Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.

1997-04-04

465

A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity  

International Nuclear Information System (INIS)

Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.

1988-01-14

466

Quantum molecular dynamics and molecular interactions studied by NMR and INS[Nuclear magnetic resonance; Proton tunnelling; Hydrogen bond  

Energy Technology Data Exchange (ETDEWEB)

The wavefunction of a particle extends into the classically forbidden barrier region of the potential energy surface. The consequence of this partial delocalisation is the phenomenon of quantum tunnelling, an effect which enables a particle to penetrate a potential barrier of magnitude greater than the energy of the particle. The tunnelling probability is an exponential function of the particle mass. The effect is therefore an important contribution to the behaviour of light atoms, in particular the proton. The hydrogen bond has long been appreciated to be an essential component of many biological and chemical systems, and the proton transfer reaction in the hydrogen bond is fundamental to many of these processes. The proton behaviour in the hydrogen bonds of benzoic acid, acetylacetone and calix-4-arene has been studied. A variety of techniques, both experimental and computational, were adopted for the study of the three hydrogen bonded systems. The complementary spectroscopic ...

2002-07-01

467

Validation of the GROMOS force-field parameter set 45A3 against nuclear magnetic resonance data of hen egg lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The quality of molecular dynamics (MD) simulations of proteins depends critically on the biomolecular force field that is used. Such force fields are defined by force-field parameter sets, which are generally determined and improved through calibration of properties of small molecules against experimental or theoretical data. By application to large molecules such as proteins, a new force-field parameter set can be validated. We report two 3.5 ns molecular dynamics simulations of hen egg white lysozyme in water applying the widely used GROMOS force-field parameter set 43A1 and a new set 45A3. The two MD ensembles are evaluated against NMR spectroscopic data NOE atom-atom distance bounds, {sup 3}J{sub NH{alpha}} and {sup 3}J{sub {alpha}}{sub {beta}} coupling constants, and {sup 1}5N relaxation data. It is shown that the two sets reproduce structural properties about equally well. The 45A3 ensemble fulfills the atom-atom distance bounds derived from NMR spectroscopy slightly less well ...

2004-12-15

468

A dinuclear Ni(I) system having a diradical Ni2N2 diamond core resting state: synthetic, structural, spectroscopic elucidation, and reductive bond splitting reactions.  

Science.gov (United States)

One-electron reduction of the square-planar nickel precursor (PNP)NiCl ( 1) (PNP (-) = N[2-P(CHMe 2) 2-4-methylphenyl] 2) with KC 8 effects ligand reorganization of the pincer ligand to assemble a Ni(I) dimer, [Ni(mu 2-PNP)] 2 ( 2), containing a Ni 2N 2 core structure, as inferred by its solid-state X-ray structure. Solution magnetization measurements are consistent with a paramagnetic Ni(I) system likely undergoing a monomer dimer equilibrium. The room-temperature and 4 K solid-state X-band electron paramagnetic resonance (EPR) spectra display anisotropic signals. Low-temperature solid-state X-band EPR data at 4 K reveal rhombic values g z = 1.980(4), g x = 2. 380(4), and g y = 2.225(4), as well as a forbidden signal at g = 4.24 for the Delta M S = 2 half field transition, in accord with 2 having two weakly interacting metal centers. Utilizing an S = 1 model, full spin Hamiltonian simulation of the low-temperature EPR spectrum on the solid ...

2008-10-15

470
471

Simulations of the Microwave Sky  

Energy Technology Data Exchange (ETDEWEB)

We create realistic, full-sky, half-arcminute resolution simulations of the microwave sky matched to the most recent astrophysical observations. The primary purpose of these simulations is to test the data reduction pipeline for the Atacama Cosmology Telescope (ACT) experiment; however, we have widened the frequency coverage beyond the ACT bands and utilized the easily accessible HEALPix map format to make these simulations applicable to other current and near future microwave background experiments. Some of the novel features of these simulations are that the radio and infrared galaxy populations are correlated with the galaxy cluster and group populations, the primordial microwave background is lensed by the dark matter structure in the simulation via a ray-tracing code, the contribution to the thermal and kinetic Sunyaev-Zel'dovich (SZ) signals from galaxy clusters, groups, and the intergalactic medium has been included, and the gas prescription to model the SZ signals has ...

2009-12-16

472

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

473

X-ray structure of sensory rhodopsin II at 2.1-? resolution  

UK PubMed Central (United Kingdom)

Sensory rhodopsins (SRs) belong to a subfamily of heptahelical transmembrane proteins containing a retinal chromophore. These photoreceptors mediate the cascade of vision in animal eyes and phototaxis...Full Text Available

2001-08-28

474

The Orbit of the Eclipsing X-ray Pulsar EXO 1722-363  

CERN Document Server

With recent and archival Rossi X-Ray Timing Explorer (RXTE) X-ray measurements of the heavily obscured X-ray pulsar EXO 1722-363 (IGR J17252-3616), we carried out a pulse timing analysis to determine the orbital solution for the first time. The binary system is characterized by a_x sin(i) = 101 +/- 3 lt-s and P_orb = 9.7403 +/- 0.0004 days (90% confidence), with the precision of the orbital period being obtained by connecting datasets separated by more than 7 years (272 orbital cycles). The orbit is consistent with circular, and e 61 degrees at the 99% confidence level, the radius of the primary is between 21 R_sun and 37 R_sun, and its mass is less than about 22 M_sun. The acceptable range of radius and mass shows that the primary is probably a supergiant of spectral type B0I-B5I. Photometric measurements of its likely counterpart are consistent with the spectral type and luminosity if the distance to the system is ...

2006-01-01

475

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...

476

The DEXD/H-box RNA Helicase DDX19 Is Regulated by an ?-Helical Switch*S?  

UK PubMed Central (United Kingdom)

DEXD/H-box RNA helicases couple ATP hydrolysis to RNA remodeling by an unknown mechanism. We used x-ray crystallography and biochemical analysis of the human DEXD/H-box...Full Text Available

2009-04-17

477

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

478

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

479

Structure of molten alkali halides  

Energy Technology Data Exchange (ETDEWEB)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-06-01

480

Structure of molten alkali halides  

International Nuclear Information System (INIS)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-01-01

481

Structural transformations in heat-resistant protective coatings on nickel alloys  

Energy Technology Data Exchange (ETDEWEB)

In this work a comprehensive metallophysical study was carried out for two aluminosilicide slip coatings of the systems Al-Si and Al-Nb-Si and an electron-beam Co-Cr-Al-Y coating on alloy EP-539 (17...19% Cr, 4...6% Co, 2.5...4% W, 4.5...6.5% Mo, 2...3% Ti, 3...4% Al, 1.4...2% Nb, balance Ni) after high-temperature testing. The protective properties of the coatings were evaluated from the results of laboratory tests for heat resistance at 1000/sup 0/C in the combustion products of diesel fuel with added sulfur at 970, 1000, and 1060/sup 0/C for 100 h and after full-scale tests for 150, 250, 400, and 700 h. Metallographic, hardness, x-ray, and micro x-ray studies of the coating were carried out. Layer-by-layer phase composition and the lattice spacing of the main phases were determined. X-ray analysis was carried out in an a DRON-1 diffractometer in copper K/sub ..-->../-radiation, and x-ray ...

1987-09-01

482

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

483

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

484

Probing the Origins of the CIV and Fe Kalpha Baldwin Effect  

CERN Document Server

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft ...

2009-01-01

485

Preliminary X-ray crystallographic studies of Bacillus subtilis SpeA protein  

UK PubMed Central (United Kingdom)

The speA gene in Bacillus subtilis encodes arginine decarboxylase, which catalyzes the conversion of arginine to agmatine. Arginine decarboxylase is an important enzyme...Full Text Available

486

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...

487

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.

1999-03-01

488

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

489

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

490

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

491

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.

2003-05-15

492

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

493

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

495

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

496

Crystallization and preliminary X-ray analysis of human liver ?-enolase  

UK PubMed Central (United Kingdom)

Enolase is a multifunctional enzyme that plays important roles in many biological and disease processes. α-Enolase from human liver (hENO1) was expressed as a soluble protein and purified by...Full Text Available

497

Crystal structure of the human adenovirus proteinase with its 11 amino acid cofactor.  

UK PubMed Central (United Kingdom)

The three-dimensional structure of the human adenovirus-2 proteinase complexed with its 11 amino acid cofactor, pVIc, was determined at 2.6 A resolution by X-ray crystallographic analysis. The fold...Full Text Available

1996-04-15

498

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-08-01

499

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-01-01