WorldWideScience
1

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

2

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

3

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential ...

2009-07-01

4

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

5

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

6

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...

7

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

8

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

9

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

11

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

12

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable ...

1996-12-31

13

Swift panchromatic observations of the bright gamma-ray burst GRB050525a  

CERN Document Server

The bright gamma-ray burst GRB050525a has been detected with the Swift observatory, providing unique multiwavelength coverage from the very earliest phases of the burst. The X-ray and optical/UV afterglow decay light curves both exhibit a steeper slope ~0.15 days after the burst, indicative of a jet break. The timing of the jet break combined with the total gamma-ray energy of the burst constrains the opening angle of the jet to be 2.5 degrees. We derive an empirical `time-lag' redshift from the BAT data of z_hat = 0.69 +/- 0.02, in good agreement with the spectroscopic redshift of 0.61. Prior to the jet break, the X-ray data can be modelled by a simple power law with index alpha = -1.2. However after 300s the X-ray flux brightens by about 30% compared to the power-law fit. The optical/UV data have a more complex decay, with evidence of a rapidly falling reverse shock component that dominates in the ...

2006-01-01

14

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection ...

1994-10-01

15

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection ...

1994-01-01

16

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

17

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

18

X-ray ablation measurements and modeling for ICF applications  

Energy Technology Data Exchange (ETDEWEB)

X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and ...

1996-09-01

19

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

20

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

21

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

22

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

23

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the ...

2009-01-01

24

Precise radiometry: Some recent aspects of fruitful interaction with atomic physics  

International Nuclear Information System (INIS)

Modern radiometric analytics demands a complex consideration of nuclear and electron shell processes, if more pretentious aims are envisaged. As an example the small variation of decay rates of radionuclides presents possibilities for information on chemical situations of decaying atoms. In principle this phenomenon is well known since many years, but now the situation is such that, e.g. in /sup 99m/Tc internal conversion, a full agreement of the difficult experiments and the respective theory was established. The secondary emission of X-rays as a consequence of high excitation of electron shells in combination with nuclear transitions supplies another example for a methodical progress of radiometry. Investigations on "5"1Cr as an electron capture nuclide have shown that chemically induced variations of the K/sub #alpha#/ to K/sub #beta#/ X-ray intensity ratio is at least qualitatively understood. (author).

1986-01-01

25

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

26

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be ...

2007-07-01

27

Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam  

International Nuclear Information System (INIS)

Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to that used for electron microscopy. The ...

1999-05-21

28

Comparative evaluation of the quantitative bone scintigraphy and the radiography in patients with ankylosing spondylitis  

International Nuclear Information System (INIS)

In 620 patients quantitative bone scintigraphy with "9"9"mTc pyrophosphate of the sacroiliac joints and of the spine was performed: 365 patients with confirmed ankylosing spondylitis, 125 patients with clinical radiological suspicion for ankylosing spondylitis (probable Bechterev) and control group of 130 healthy individuals. By comparison of the activity in zones of interest of the sacroiliac joints, the spine and sacrum, the following indices were determined: sacroiliac (separately for the left and right sacroiliac joints), index D_1_0/sacrum, index L_4/sacrum and index C_7/sacrum. The scintigraphic finding was compared to the X-ray one and to the radiological stage of the disease. A long-term follow-up of the patients was carried out during 1-6 years with scintigraphic, X-ray and clinical investigations. Emphasis was laid upon the posibilities for quantitative scintigraphy for early diagnostics of ankylosing spondylitis. The ...

33

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

34

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum ...

2004-08-23

35

Information detective quantum efficiency of X-ray film-intensifier foil systems  

Energy Technology Data Exchange (ETDEWEB)

The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.

1988-04-01

36

Information detective quantum efficiency of X-ray film-intensifier foil systems  

International Nuclear Information System (INIS)

The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).

37

Changes in the structure and superconducting transition temperature of A-15 compounds under the effect of high pressure and shear strain  

Energy Technology Data Exchange (ETDEWEB)

The study is concerned with the combined effect of high pressure and shear strain on the properties of the A-15 intermetallics Nb3Sn and Nb3Al0.75Ge0.25. The properties discussed are the superconducting transition temperature, the width and intensity of the X-ray diffraction lines, and the width and shape of the Mossbauer absorption lines. It is shown that the combined effect of high pressure and shear strain leads to an intense generation of defects in polycrystalline specimens; the size of the ordered regions does not exceed 300 A even under the least severe conditions. 5 references.

1985-01-01

38

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...

2005-07-01

39

Radiation, adriamycin, and skin reactions: effects of radiation and drug fractionation, hyperthermia, and tetracycline. [X rays  

Energy Technology Data Exchange (ETDEWEB)

The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where the initiation of drug treatment succeeded the initiation of ...

1981-06-01

40

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial ...

2008-06-01

41

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

42

Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs  

Energy Technology Data Exchange (ETDEWEB)

The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible trend of a slightly ...

1999-02-23

43

A facile method for the room-temperature synthesis of water-soluble magnetic Fe3O4 nanoparticles: Combination of in situ synthesis and decomposition of polymer hydrogel  

British Library Electronic Table of Contents (United Kingdom)

We propose and demonstrate a facile room-temperature synthetic method for obtaining water-soluble magnetic Fe3O4 nanoparticles (NPs) by combining the in situ synthesis and decomposition of a magnetic polymer hydrogel. The Fe3O4 NPs with average diameters of 6.3-8.3nm were synthesized in a cross-linked polyacrylamide (PAAm) hydrogel by coprecipitating iron ions. The decomposition of the magnetic polymer hydrogel by an aqueous solution of sodium hydroxide led to the transfer of Fe3O4 NPs into the aqueous medium. The NPs can be dispersed stably in water for more than three months. The Fe3O4 NPs were characterized by X-ray photoelectron spectra (XPS), X-ray powder diffraction (XRD), transmission electron microscope (TEM), and Fourier transform infrared spectroscopy (FT-IR). The saturation magn...

2011-01-01

44

Study of titanium-niobium alloys manufactured by magnesium thermic reduction of chlorides  

International Nuclear Information System (INIS)

Chemical and phase homogeneity of titanium-niobium sponge, produced by a combined magnesium-thermic reduction of niobium pentachloride and titanium tetrachloride mixtures, is investigated. It is ascertained that a sponge consists of spherical shape particles and has a large number of pores. Particle sizes are reduced with niobium being substituted for titanium from 50-500 #mu#m for titanium sponge to 1-40 #mu#m for niobium one, which testifies to the bormation in a titanium-niobium sponge of an alloy and not a mechanical mixture. A number of solid solutions is detected by X-ray phase analysis. Lattice parameters are determined.

45

Stresses and interfacial structure in Au-Ni and Ag-Cu metallic multilayers  

Energy Technology Data Exchange (ETDEWEB)

Metallic multilayers offer a fantastic playground to investigate elastic stresses in films of nanometer thickness. We will present and discuss a few examples from our recent work on Au-Ni and Ag-Cu systems where we combined plate bending measurements and electron or X-ray diffraction to investigate stress buildup and interfacial mixing. Comparing these two cases we discuss the results with respect to basic parameters like the misfits in lattice parameters and in elastic moduli, the mixing enthalpies and the surface energies.

2004-03-15

46

Crystal chemistry of hydroxyl and water in silicate minerals. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This was a project to investigate the crystal chemistry of OH and H{sub 2}O substitution in silicate minerals by use of X-ray and neutron diffraction methods combined with IR spectroscopy and to interpret and generalize the results using an electrostatic model for these mineral structures. Using these data together with published H position data electrostatic parameters for H sites were calculated from a simple electrostatic model. The data were then used to refine the model for incorporation of H into the wadsleyite structure. This has led to recent work on the synthesis and characterization of hydrous wadsleyites.

1998-06-01

47

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

48

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum ...

2010-11-24

49

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

50

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

51

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

52

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

53

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

54

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

55

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the ...

1993-10-13

56

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

Energy Technology Data Exchange (ETDEWEB)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the {mu}m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density ...

2008-12-15

57

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

International Nuclear Information System (INIS)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density parameters on two 200 mm ...

2008-12-01

58

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral formation in this ...

2011-05-05

59

Structural, electronic and magnetic properties of splat-quenched FeCsub(x) alloys (x<0.05)  

International Nuclear Information System (INIS)

The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity ...

2006-01-01

60

Stabilization of high-temperature antimony oxide with molybdenum incorporation. Structure of Mo-doped Sb/sub 2/O/sub 4/ by powder neutron diffraction and extended X-ray absorption fine structure spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

It has been discovered that the presence of MoO/sub 3/ lowers the ..cap alpha..-..beta.. transition in Sb/sub 2/O/sub 4/ from 935 to 850/sup 0/C with concurrent dissolution of Mo in the high-temperature (..beta..) form. The structure of Mo-doped ..beta..-Sb/sub 2/O/sub 4/ has been investigated by powder neutron diffraction, extended X-ray absorption fine structure (EXAFS) and Raman spectroscopies, and scanning-electron microscopy (SEM). Cell parameters: a = 12.0571 (12) A, b = 4.8335 (1) A, c = 5.3838 (6) A, ..beta.. = 105.579 (5)/sup 0/, monoclinic, space group C2/c, Z = 4. Combining the results of these techniques leads to the hypothesis that Mo is located interstitially within channels of electron density in the Sb/sub 2/O/sub 4/ structure with concurrent vacancy of two Sb/sup III/ atoms. There is no apparent oxygen deficiency in the resulting structure. 25 references, 6 figures, 3 tables.

1985-10-09

61

Local structure of Ca dopant in BaTiO_3 by Ca K-edge X-ray absorption near-edge structure and first-principles calculations  

International Nuclear Information System (INIS)

The local environment of Ca dopants in barium titanate, BaTiO_3, is investigated by Ca K-edge X-ray absorption near-edge structure (XANES) spectroscopy. In conjunction with experiments, first-principles calculations by two methods are systematically made. The projector-augmented wave (PAW) method is used to optimize the local structure and obtain the formation energy. The augmented plane wave plus local orbitals method is adopted to obtain theoretical XANES spectra. A comparison between experimental and theoretical XANES spectra shows that Ca dopants are located at the Ba"2"+ sites forming Ca"2"+. Formation energy calculations of Ca doped BaTiO_3 by the PAW method also give the same results. The Ca atom in BaTiO_3 is off-centering in comparison with the Ba site in BaTiO_3. The off-centering of Ca atom is newly revealed by the combination of XANES spectroscopy and first-principles DFT calculations.

2010-06-01

62

Inverse spinel materials. A new class of high voltage cathode materials for Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

The influence of Cr on the structure and electrochemical properties of LiCoVO{sub 4} was studied using X-Ray diffraction, scanning electron microscopy, Raman Spectroscopy and cycle tests. Doping levels up to 10 mol% were achieved, which improved the electrochemical stability of the structure of LiCoVO{sub 4}, resulting in a significant increase in the initial charge and discharge capacity. The Raman spectroscopy data for the Cr-doped LiCoVO{sub 4} is similar as for LiCoVO{sub 4}. The replacement of a dopant for the Co-ion in the inverse spinel structure causes several Raman shifts. The X-ray diffraction patterns show no new phases and combined with the Raman spectroscopy data it is concluded that the Cr dopant will be located at the octahedral site (16d) where they create an electronic pathway that enhances the electronic conductivity. However, the capacity dropped significantly after prolonged cycling, which is due to the ...

2003-07-01

63

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

International Nuclear Information System (INIS)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain ...

1987-01-01

64

Element-selective thermal x-ray magnetic circular dichroism study through the magnetic compensation temperature of Ho{sub 6}Fe{sub 23}  

Science.gov (United States)

We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.

2005-09-01

65

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy combination. A system for ...

66

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

67

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

69

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

70

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

71

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...

2001-09-23

72

X-ray absorption spectroscopy of bacterial sulfur globules  

Energy Technology Data Exchange (ETDEWEB)

Sulfur K-edge X-ray absorption spectroscopy is a powerful in situ probe of sulfur biochemistry in intact cells and tissues. Under favorable circumstances the technique can provide quantitative information on the chemical identify of the sulfur species that are present in a sample. Prange et al. have recently reported an X-ray absorption spectroscopic study of bacterial sulfur storage globules. Unfortunately there are substantial problems with the experimental technique employed that, they contend, lead to completely erroneous conclusions. In the more recent of their two papers Prange et al. employed a curve-fitting method similar to that used by us (for more than 10 years). In essence, the method employs simply fitting a linear combination of the spectra of standard compounds to that of the unknown, in this case cultures of bacterial cells. This type of analysis can provide quantitative estimates of the individual sulfur ...

2002-08-01

75

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

76

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

82

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

83

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

84

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

85

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

87

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

91

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

92

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

93

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

94

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

95

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

96

Transformation kinetics and microstructures of Ti17 titanium alloy during continuous cooling  

International Nuclear Information System (INIS)

We have investigated the microstructure evolutions in the Ti17 near #beta# titanium alloy during heat treatments. The phase transformation has first been studied experimentally by combining X-ray diffraction analysis, electrical resistivity and microscopy observations. From a series of isothermal treatments, a IT diagram has been determined, which takes into account the different morphologies. Then, a Johnson-Mehl-Avrami-Kolmogorov (JMAK) model has been successfully used to describe the phase transformation kinetics during either isothermal or cooling treatments. Finally, the coupling of the JMAK model to the finite element software ZeBuLoN allowed us to investigate the evolution of the spatial distribution of the different morphologies during the cooling of an aircraft engine shaft disk after forging.

2007-03-15

97

The duke XUV FEL storage ring facility  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)

1998-11-01

98

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

99

La{sup 3+} modified Al{sub 2}O{sub 3} as a support for CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.

1993-12-31

100

Increased osteoblast adhesion on nanograined Ti modified with KRSR  

British Library Electronic Table of Contents (United Kingdom)

Peptide sequences such as lysine-arginine-serine-arginine (KRSR) selectively bind transmembrane proteoglycans (e.g. heparin sulfate) of osteoblasts (bone-forming cells) and are, therefore, actively being investigated for orthopedic applications. Further, nanophase materials (or materials with grain or particle sizes less than 100 nm) are promising new materials that promote new bone growth more than compared to conventional (that is, micron grain or particle size) materials. To combine the above two promising approaches for improving orthopedic implants, the objective of this in vitro study was to functionalize titanium (Ti) surfaces (both nanophase and conventional) with KRSR peptides and study their osteoblast cell adhesive properties. Materials were characterized by X-ray photoelectron ...

2007-01-01

101

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

102

Chemical composition of passive films on AISI 304 stainless steel  

Energy Technology Data Exchange (ETDEWEB)

Chemical characterization of passive films formed on AISI 304 austenitic stainless steel, in a borate/boric acid solution at pH 9.2, under various conditions of potential, temperature, and polarizations time, was made by Auger electron spectroscopy combined with ion sputtering, and x-ray photoelectron spectroscopy (XPS). The depth chemical composition, thickness, and duplex character of the passive layers were determined after processing AES sputter profiles by their quantitative approach based on the sequential layer sputtering model. Moreover, separated contributions of elements in their oxidized and unoxidized state could be disclosed from part to part of the oxide-alloy interface. The XPS study specified the chemical bondings which take placed inside the film, between Fe and oxygen (and water).

1994-12-01

103

CHARACTERIZATION OF DEXTRIN PREPARED BY COMMON NEUTRAL AND THERMOSTABLE a-AMYLASES  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT With corn starch as raw material, dextrin was prepared by the combined application of common neutral and thermostable a-amylases in this study. The effects of reaction temperature, reaction time, addition of common neutral and thermostable a-amylases on dextrose equivalent (DE)-value of dextrin were investigated. The obtained dextrin with a DE value of 20.43 was evaluated for morphology, crystallography, particle size distribution and thermal property by scanning electron microscope, X-ray diffractometer, light scattering particle size analyzer and thermogravimetric analyzer. The results showed that the amorphous regions in the core part of corn starch were completely hydrolyzed and only the fractured crystalline surface remained. The particle size of the dextrin change significan...

2010-01-01

104

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

105

Application of neutron diffraction in chemistry. Pt. 2  

Energy Technology Data Exchange (ETDEWEB)

This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a combination of several neutron scattering techniques may prove ...

1982-01-01

106

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

107

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

108

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

109

RF plasma nitriding of severely deformed iron-based alloys  

International Nuclear Information System (INIS)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher ...

2003-05-15

110

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...

2000-08-01

111

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

112

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

113

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

114

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

115

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

116

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

117

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

118

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

119

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

120

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

121

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

122

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

123

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

124

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

125

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

126

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

127

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

128

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

129

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

130

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

131

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

132

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

133

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

134

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

135

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

136

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's ...

2007-05-07

137

The role of computed tomography in complex facial trauma  

Energy Technology Data Exchange (ETDEWEB)

Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury ...

1988-02-15

138

Radiation hardening of final optics for an ICF reactor  

International Nuclear Information System (INIS)

Radiation damage of the final optical components in an Inertial Confinement Fusion (ICF) reactor is a crucial issue for development of a laser-fusion reactor. To some extent, this problem will be encountered in the National Ignition Facility (NIF), but there, the integrated radiation dose will be considerably less than that encountered in a future reactor. This extremely harsh radiation environment necessitates shielding the ICF optics from direct neutron and x-ray bombardment. Several approaches have been suggested, such as the use of grazing incidence metal mirrors or fused silica wedge deflectors. While metal mirrors can withstand a larger radiation dose, their focusing qualities pose problems. Therefore wedge deflectors, originally suggested by Lawrence Livermore National Laboratory (LLNL) staff, represent a promising alternative. Radiation hardening of the fused silica deflectors using a new combined thermal/optical annealing approach is ...

1995-04-24

139

Optimization of microstructure and properties of in situ formed #beta#-O-sialon-TiN composite  

International Nuclear Information System (INIS)

A powder mixture of #alpha#-Si_3N_4, Al_2O_3, and TiO_2 was hot-pressed using different sintering cycles to search for an optimum in situ formed #beta#-O-sialon-TiN composite. The impulse excitation technique (IET), high-temperature X-ray diffraction (HTXRD), and scanning electron microscopy (SEM) were used to investigate the microstructure. Below the temperature of 1300 deg. C, the high-temperature internal friction (Q "-"1) decreases with the increase of sintering temperature, whereas the density of the material increases with the increase of sintering temperature. At a sintering temperature higher than 1850 deg. C, the ceramic could not be densified and O-sialon was not formed. Also, the mechanical properties of ceramics hot-pressed using different sintering cycles were assessed. The ceramic hot-pressed at 1700 deg. C for 10 min displays a combination of high hardness and good fracture toughness, due to an optimum ...

2006-07-15

140

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as ...

143

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

144

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

145
146

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

147

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

148

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

149

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

151

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

152

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

153

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

154

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

156

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

157

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

158

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

159

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

160

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

161

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

162

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

163

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

164

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

165

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

166

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

167

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

168

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

169

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

170

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

171

Materials research and beam line operation utilizing NSLS. Progress report  

Energy Technology Data Exchange (ETDEWEB)

MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year the full 242 operational days were utilized. Beam line test and evaluation consumed 21 days with eight MATRIX groups combining to use 170 days. General user demand for use of the beam line continues to be strong and three groups were provided 51 operating days. Research production has been growing as NSLS and the beam line become a more stable type of operation. For 1990 the ...

1991-10-01

172

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

Energy Technology Data Exchange (ETDEWEB)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even ...

1987-04-01

173

Development of Intelligent Setting System for Fracture Based on X-Ray Image  

Energy Technology Data Exchange (ETDEWEB)

In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-ray image peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power polymerization curved surface fitting. Master-slave ...

2006-10-15

174

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

175

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

176

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

177

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

178

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

179

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

180

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

181

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

182

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

183

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

184

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

185

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

186

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

187

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

188

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

189

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak ...

2005-01-01

190

Thermodynamics and stability of the mixed-conducting Sr-Fe-Co-O system.  

Energy Technology Data Exchange (ETDEWEB)

Mixed-conducting Sr-Fe-Co oxides have potential applications in dense ceramic membranes for high-purity oxygen separation and/or methane conversion to produce syngas (CO + H{sub 2}), because of their combined high electronic/ionic conductivity and significant oxygen permeability. We studied the crystal structure and microstructure of the system in X-ray diffraction experiments and by using scanning electron microscopy, respectively. Thermogravimetric analysis was conducted on the SrFeCo{sub 0.5}O{sub x} sample in environments of various oxygen partial pressures (pO{sub 2}). Conductivity increased while weight decreased with increasing temperature. Activation energy decreased while conductivity increased with increasing pO{sub 2}. The pO{sub 2}-dependent conducting behavior of the SrFeCo{sub 0.5}O{sub x} system can be understood by considering the trivalent-to-divalent transition of transition-metal ions.

1999-04-28

191

Structure and magnetic properties of the Al1-xGaxFeO3 family of oxides: A combined experimental and theoretical study  

International Nuclear Information System (INIS)

Magnetic properties of the Al1-xGaxFeO3 family of oxides crystallizing in a non-centrosymmetric space group have been investigated in detail along with structural aspects by employing X-ray and neutron diffraction, Moessbauer spectroscopy and other techniques. The study has revealed the occurrence of several interesting features related to unit cell parameters, site disorder and ionic size. Using first-principles density functional theory based calculations, we have attempted to understand how magnetic ordering and related properties in these oxides depend sensitively on disorder at the cation site. The origin and tendency of cations to disorder and the associated properties are traced to the local structure and ionic sizes. -- Graphical abstract: We have studied both experimentally and theoretically the important role of disorder at the cation site on magnetic and related properties of the Al1-xGaxFeO3 family of oxides crystallizing in a non-centrosymmetric space ...

2011-03-01

192

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial properties of the coatings. ...

2006-08-30

193

Relationships between the state of oxidation and catalytic activity of chromium, molybdenum and tungsten in hydrocarbon reactions; Beziehungen zwischen Oxidationszustand und katalytischer Aktivitaet von Chrom, Molybdaen und Wolfram in Kohlenwasserstoffreaktionen  

Energy Technology Data Exchange (ETDEWEB)

The knowledge shown in this work of the relationships between the oxidation stage of chromium, molybdenum and tungsten and their catalytic activity in some hydrocarbon reactions was achieved by the combination of separate investigations of reduction properties and the catalytic activity of the catalysts concerned. To characterize the electronic state of the reduced surfaces, X-ray photo-electronic spectroscopy was mainly used, supplemented by electron spin resonance. The catalyst activity was measured in conventional apparatus (flow, pulse and gradient-free reactors). (orig.) [Deutsch] Die in dieser Arbeit dargestellten Erkenntnisse ueber die Zusammenhaenge zwischen der Oxidationsstufe von Chrom, Molybdaen und Wolfram und ihrer katalytischen Aktivitaet in einigen Kohlenwasserstoffreaktionen wurden durch die Kombination getrennter Untersuchungen ueber Reduktionseigenschaften und katalytische Aktivitaet der betreffenden Katalysatoren erzielt. ...

1992-02-17

194

Orion's Bar: Physical Conditions across the Definitive H+ / H0 / H2 Interface  

CERN Document Server

Previous work has shown the Orion Bar to be an interface between ionized and molecular gas, viewed roughly edge on, which is excited by the light from the Trapezium cluster. Much of the emission from any star-forming region will originate from such interfaces, so the Bar serves as a foundation test of any emission model. Here we combine X-ray, optical, IR and radio data sets to derive emission spectra along the transition from H+ to H0 to H2 regions. We then reproduce the spectra of these layers with a simulation that simultaneously accounts for the detailed microphysics of the gas, the grains, and molecules, especially H2 and CO. The magnetic field, observed to be the dominant pressure in another region of the Orion Nebula, is treated as a free parameter, along with the density of cosmic rays. Our model successfully accounts for the optical, IR and radio observations across the Bar by including a significant magnetic pressure and also heating ...

2008-01-01

195

Multilayered Nano-Microcomposite Ti-Al-N/TiN/Al_2O_3 Coatings. Their Structure and Properties  

International Nuclear Information System (INIS)

This paper presents the first results on formation and study of structure and properties of micro- and nanocomposite combined coatings. By means of modeling the deposition processes (deposition conditions, current density-discharge, plasma composition and density, voltage) we formed the three-layer nanocomposite coatings of Ti-Al-N/Ti-N/Al_2O_3. The coating composition, structure and properties were studied using physical and nuclear-physical methods. The Rutherford proton and helium ion backscattering, scanning electron microscopy with microanalysis, grazing incidence X-ray diffraction, as well as nanohardness tests (hardness) were used. Measurements of wear resistance and corrosion resistance in NaCl, HCl and H_2SO_4 solutions were also performed. For testing mechanical properties such characteristics of layered structures as hardness H, elastic modulus E: H"3/E"2 etc. were measured. It is demonstrated that the formed three-layer ...

2011-07-01

196

Melilite formation in a samarium-stabilized #alpha#-sialon ceramic during postsintering heat treatments  

International Nuclear Information System (INIS)

The formation of the melilite solid solution phase (M'), Sm_2Si_3_-_xAl_xO_3_+_xN_4_-_x, in an #alpha#-sialon sample of overall composition Sm_0_._6Si_9_._2_8Al_2_._6_9O_1_._3_6N_1_4_._7_6, was studied as a function of time in the temperature interval 1,375--1,525 C. The #alpha#-sialon ceramic contained only minor amounts of the 21R sialon polytype and some residual grain-boundary glass before heat treatment. In situ studies by high-temperature X-ray diffraction were combined with postsintering heat treatment followed by quenching. The M'-phase was found to be formed by two different mechanisms: either crystallization of the residual grain-boundary liquid or a direct decomposition of the #alpha#-sialon phase. The liquid crystallized during the first 10--15 min of heat treatment, yielding a rapid M'-phase formation, and further formation of M'-phase continued at a much slower rate, related to the decomposition of #alpha#-sialon.

197

Mechanisms controlling the leaching kinetics of fixated flue gas desulfurization (FGD) material under neutral and acidic conditions.  

Science.gov (United States)

A number of agricultural and engineering uses for fixated flue gas desulfurization (FGD) material exist; however, the potential for leaching of hazardous elements has limited widespread application and the processes controlling the leaching of this material are poorly understood. In this study, a flow-through rotating-disk system was applied to elucidate the relative importance of bulk diffusion, pore diffusion, and surface chemical reaction in controlling the leaching of fixated FGD material under pH conditions ranging from 2.2 to 6.8. Changing the hydrodynamics in the rotating disk system did not affect the leaching kinetics at both pH 2.2 and 6.8, indicating that bulk diffusion was not the kinetic-limiting step. Application of the shrinking core model (SCM) to the data suggested a surface reaction-controlled mechanism, rather than a pore diffusion mechanism. The leaching of fixated FGD material increased with decreasing pH, suggesting it can be described by a ...

2007-05-07

198

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were ...

1979-01-01

199

Latest Observational Constraints on Cardassian Models  

CERN Document Server

Constraints on the original Cardassian model and the modified polytropic Cardassian model are examined from the latest derived 397 Type Ia supernova (SNe Ia) data, the size of baryonic acoustic oscillation peak from the Sloan Digital Sky Survey (SDSS), the position of first acoustic peak of the Cosmic Microwave Background radiation (CMB) from the five years Wilkinson Microwave Anisotropy Probe (WMAP), the x-ray gas mass fractions in clusters of galaxies, and the observational H(z) data. In the original Cardassian model with these combined data set, we find $\\Omega_{m0}=0.271^{+0.014}_{-0.014}, n=0.035^{+0.049}_{-0.049}$ at $1 \\sigma$ confidence level. And in the modified polytropic Cardassian model, we find that $\\Omega_{m0}=0.271^{+0.014}_{-0.015}$, $n=-0.091^{+0.331}_{-1.908}$ and $\\beta=0.824^{+0.750}_{-0.622}$ within $1\\sigma$ confidence level. According to these observations, the acceleration of the universe begins at ...

2009-01-01

200

Histamine Molecule and Dianion Oxalate are Efficient Blocks for Building 2D Supramolecular Networks  

British Library Electronic Table of Contents (United Kingdom)

One salt and two Cu(II) complexes (H2hsm)(ox), 1, [Cu(hsm)(ox)], 2, and [Cu(hsm)(ox)H2O], 3, have been synthesized and X-ray characterized (hsm is histamine and ox2? is the oxalate dianion). Starting from the prochiral tetracoordinated complex 2, pentacoordinated complex 3 crystallizes as a racemic mixture of the enantiomeric ? and ? isomers, in space group P21/c. In all cases, the side chain of the hsm group is gauche, allowing the formation of strong hydrogen bonds in the salt 1, and to chelate the metal center in complexes 2 and 3. The combination hsm/ox seems to favor the formation of 2D supramolecular structures (planes or wavy planes), through efficient networks of N?H???O hydrogen bonds. Cell parameters: 1, P21/c, a?=?6.260 (2) ?, b?=?11.500 (4) ?, c?=?12.525 (4) ?, ??=?104.047 (17)...

2011-01-01

201

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1991-01-01

202

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1764-01-01

203

Evolution of defect structures during cold rolling of ultrafine-grained Cu and Cu-Zn alloys: Influence of stacking fault energy  

Energy Technology Data Exchange (ETDEWEB)

Samples of pure Cu, bronze (Cu-10 wt.% Zn) and brass (Cu-30 wt.% Zn) with stacking fault energies (SFE) of 78, 35, and 14 mJ/m{sup 2}, respectively, were processed by high-pressure torsion (HPT) and by a combination of HPT followed by cold-rolling (CR). X-ray diffraction measurements indicate that a decrease in SFE leads both to a decrease in crystallite size and to increases in microstrain, dislocation and twin densities for the HPT and HPT + CR processed ultrafine-grained (UFG) samples. Compared with processing by HPT, subsequent processing by CR refines the crystallite size of all samples, increases the twin densities of UFG bronze and brass, and increases the dislocation density in UFG bronze. It also decreases the dislocation density in UFG brass and leads to an unchanged dislocation density in UFG copper. The results suggest there may be an optimum stacking fault energy for dislocation accumulation in UFG Cu-Zn alloys and this has ...

2008-02-15

204

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force microscopy (AFM) ...

2000-09-01

205

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the response of the complete detector formed by an ...

206

Develop techniques for ion implantation of PLZT [lead-lanthanum-zirconate-titanate] for adaptive optics  

International Nuclear Information System (INIS)

Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of a structure at ...

207

A structural and corrosion study of triethoxysilyl and perfluorooctyl functionalized polyhedral silsesquioxane nanocomposite films on AA 2024 alloy  

International Nuclear Information System (INIS)

A tri-functional polyhedral oligomeric silsesquioxane (POSS) based silane precursor R_xR_yR_z(SiO_3_/_2)_n (x + y + z = n = 6, 8, 10, ...) bearing 3-(N-(3-triethoxysilylpropyl)ureido)propyl, isooctyl and perfluoropropyl groups was synthesized and investigated as corrosion protective coating for AA 2024 alloy. Infrared reflection-absorption (IR RA) combined with X-ray photoelectron spectroscopy and atomic force microscopy provided information about partial self-assembling of coatings having a fluorine enriched upper layer with a low surface energy (#gamma#"t"o"t = 12.37 mN/m). The structural changes that accompanied corrosion produced under chronocoulometrical conditions were assessed from ex-situ IR RA spectra. A new band at 1690-1700 cm"-"1 appeared above the corrosion potential, and was assigned to the formation of amidonium ions and consequent relaxation of urea-urea associations.

2010-03-01

208

RF plasma nitriding of severely deformed iron-based alloys  

Energy Technology Data Exchange (ETDEWEB)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the expense of the ...

2003-05-15

209

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...

2003-11-01

210

Fractionation of combined heat and radiation in asynchronous CHO cells. II. The role of cell-cycle redistribution  

Science.gov (United States)

Asynchronous Chinese hamster ovary (CHO) cells treated with conditioning hyperthermia (10 min at 45/sup 0/C) followed immediately by x irradiation with 4 Gy at room temperature display a decreased radiation response when either irradiated, or heated and irradiated again 24 h later. In addition, conditioning by 4 Gy of x radiation alone followed at 24 h by the combined heat and radiation treatment als resulted in a larger radiation D/sub 0/. Since the differential cell-cycle responses to heat- and x-ray-induced lethality are well established for CHO cells, the potential role of cell-cycle redistribution in the observed radiation desensitization was investigated by flow cytometry. At 24 h after the combined treatment, the fraction of the cells found in the G/sub 2/ + M portion of the DNA histograms was about three times that of the controls and there was a concomitant reduction in both the G/sub 1/ and S fractions. Similar ...

1979-11-01

211

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

212

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

213

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

214

Standard samples for X-ray radiometric analysis of substance composition  

International Nuclear Information System (INIS)

Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.

215

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

216

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

217

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

218

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

219

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

220

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

221

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

222

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

223

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

224

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

225

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

226

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

227

Applications of X-ray scattering in pharmaceutical science  

British Library Electronic Table of Contents (United Kingdom)

The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.

2011-01-01

228

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

229

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

230

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

231

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

232

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

233

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

235

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

236

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

237

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

239

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

240

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

241

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

242

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

243

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

246

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

247

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

248

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

249

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

250

On the Z-dependence of K#alpha#_1/K#beta#_1 X-ray intensity ratio  

International Nuclear Information System (INIS)

1976. Germany Ramaswamy, MK Birla Inst. of Tech. and Science, Pilani

1976-03-29

251

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

252

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

253

Koji Mukai's Bibliography - Astrophysics Science Division Staff ...  

Science.gov (United States)

Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...

254

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

255

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

257

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

258

Future instrumentation for the study of the Warm-Hot Intergalactic Medium  

CERN Document Server

We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.

2008-01-01

259

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

260

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

261

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

262

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

263

Density Gradients for Isolation of Mononuclear Blood Cells for ...  

Science.gov (United States)

... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...

2011-05-15

266

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

267

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a few tens of nanometers. Historically, while ...

2002-09-23

268

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

269

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

270

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

271

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

272

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

273

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

274

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

275

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

276

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

277

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

278

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

279

Structural intermediates in the assembly of taxoid-induced microtubules and GDP-tubulin double rings: time-resolved X-ray scattering.  

UK PubMed Central (United Kingdom)

We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available

1996-05-01

280

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

281

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

282

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

283

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

284

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

285

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell ...

286

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

287

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

288

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

289

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

290

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

291

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

292

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

293

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

294

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

295

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

296

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

297

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

298

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

299

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

300

Comments on possible preferential order-disorder in A-15 compounds based upon Nb  

International Nuclear Information System (INIS)

The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).

301

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

302

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

303

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

304

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

305

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

306

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

307

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

308

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

309

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

310

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

311

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

312

Thermal stability of nanocomposite CrC/a-C:H thin films  

International Nuclear Information System (INIS)

The thermal stability of low-friction Me-C/a-C:H coatings is important for their potential applications in the tool and automotive industry. Recently we showed that CrC _x/a-C:H coatings prepared by unbalanced magnetron sputtering of a Cr target in Ar + CH_4 glow discharges exhibit a nanocomposite structure where metastable fcc CrC nanocrystals are encapsulated by an a-C:H phase. Here, we present the structural evolution of these nanocomposite CrC/a-C:H coatings during annealing. High-temperature X-ray diffraction in vacuum and differential scanning calorimetry (DSC) combined with thermo-gravimetric analysis in Ar atmosphere indicate decomposition of the formed metastable fcc CrC phase and subsequent formation of Cr_3C_2 and Cr_7C_3 and structural transformation of the a-C:H matrix phase towards higher sp"2 bonding contents at temperatures above 450 deg. C. Combined DSC and mass spectrometer analysis as well as elemental ...

2007-05-07

313

Identifying surface structural changes in layered Li-excess nickel manganese oxides in high voltage lithium ion batteries: A joint experimental and theoretical study  

Energy Technology Data Exchange (ETDEWEB)

High voltage cathode materials Li-excess layered oxide compounds Li[Ni{sub x}Li{sub 1/3-2x/3}Mn{sub 2/3-x/3}]O{sub 2} (0 < x < 1/2) are investigated in a joint study combining both computational and experimental methods. The bulk and surface structures of pristine and cycled samples of Li[Ni{sub 1/5}Li{sub 1/5}Mn{sub 3/5}]O{sub 2} are characterized by synchrotron X-Ray diffraction together with aberration corrected Scanning Transmission Electron Microscopy (a-S/TEM). Electron Energy Loss Spectroscopy (EELS) is carried out to investigate the surface changes of the samples before/after electrochemical cycling. Combining first principles computational investigation with our experimental observations, a detailed lithium de-intercalation mechanism is proposed for this family of Li-excess layered oxides. The most striking characteristics in these high voltage high energy density cathode materials are (1) formation ...

2011-09-06

314

Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice  

International Nuclear Information System (INIS)

A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse cytophotometry, "3H-thymidine uptake labeling ...

315

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days ...

2001-01-01

316

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and ...

2009-08-11

317

X-ray and HeI 1.0830 mu emission from protostellar jets  

CERN Document Server

Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical models of intermediately fast (> 500 - ...

2006-01-01

318

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power law model with ...

2010-01-01

319

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the ...

2005-01-01

320

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an ...

2008-02-01

321

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

322

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

323

He-like ions as practical astrophysical plasma diagnostics: From stellar coronae to active galactic nuclei  

CERN Document Server

We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, allowing plasmas with ...

2011-01-01

324

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

325

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, ...

2007-01-01

326

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

Energy Technology Data Exchange (ETDEWEB)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray intensity ratio was found to ...

1983-09-01

327

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

International Nuclear Information System (INIS)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ratio was found to be an ...

1982-10-01

328

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...

2010-06-02

329

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of ...

2008-01-01

330

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide ...

1987-05-13

331

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. ...

2000-08-01

332

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...

1981-01-01

333

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

334

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

335

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values ...

1987-01-01

336

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the ...

1987-01-01

337

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

338

Investigation of new materials for SOFC applications; Untersuchungen zum Einsatz neuer Werkstoffe fuer SOFC-Anwendungen  

Energy Technology Data Exchange (ETDEWEB)

Fuel cells based on solid oxides ('SOFC') are excellent alternative devices for power generation, when they are operated at high temperature, e.g. above 600 C. Having only fixed parts for the power generating part of the device is only one advantage of the fuel cell. Due to their unique design, these devices offer a maximum of efficiency for energy conversion compared to conventional power generating systems, which are mainly based on turbines. One aim of this thesis is the examination of alternative electrolyte and cathode materials for the SOFC applications at reduced temperatures, which means in the temperature range between 600 C and 750 C. For the first main task, several materials from the oxygen ion conducting electrolytes were selected. Different strontium and magnesium doped lanthanum gallate (LSGM) materials with additional transition metal doping were selected and prepared via two different preparation methods. The optimum calcining conditions were ...

2007-05-04

339

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

340

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

341

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

342

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

343

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

344

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

345

Studies of L x-rays from 64 MeV iodine projectiles in collision with gas targets  

International Nuclear Information System (INIS)

We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)

1997-11-17

346

Simulation Studies of the X-Ray Free-Electron Laser Oscillator  

Energy Technology Data Exchange (ETDEWEB)

Simulations of the x-ray free-electron laser (FEL) oscillator are presented that include transverse effects and realistic Bragg crystal properties with the two-dimensional code GINGER. In the present cases considered the radiation divergence is much narrower than the crystal acceptance, and the numerical algorithm can be simplified by ignoring the finite angular bandwidth of the crystal. In this regime GINGER shows that the saturated x-ray pulses have 109 photons and are nearly Fourier-limited with peak powers in excess of 1 MW. Wealso include preliminary results for a four-mirror cavity that can be tuned in wavelength over a few percent, with future plans to incorporate the full transverse response of the Bragg crystals into GINGER to more accurately model this tunable source.

2009-08-14

347

Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+  

British Library Electronic Table of Contents (United Kingdom)

The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...

2009-01-01

348

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

349

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

1984-01-01

350

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...

351

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

352

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...

1981-10-01

353

NEXAFS microscopy of polymeric materials: Successes and challenges encountered when characterizing organic devices  

Energy Technology Data Exchange (ETDEWEB)

We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.

2009-09-01

354

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

355

Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.

2009-12-11

356

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

357

Influence of alloying effect on X-ray fluorescence parameters of Co and Cu in CoCuAg alloy films  

British Library Electronic Table of Contents (United Kingdom)

In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.

2009-01-01

358

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

359

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

360

Exploring the Physics of Type Ia Supernovae Through the X-ray Spectra of their Remnants  

CERN Document Server

We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-ray emission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.

2005-01-01

361

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

362

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

363

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

364

Cluster Geometry & Inclinations from Deprojection Uncertainties  

CERN Document Server

{The determination of cluster masses is a complex problem that would be aided by information about the cluster shape and orientation (along the line-of-sight).} {It is in this context, that we have developed a scheme for identifying the intrinsic morphology and inclination of a cluster, by looking for the signature of the true cluster characteristics in the inter-comparison of the different deprojected emissivity profiles (that all project to the same X-ray brightness distribution) and by using SZe data when available.} {We deproject the cluster X-ray surface brightness profile under the assumptions of four different geometry and inclination configurations for the observed system; these 4 configurations correspond to four extreme geometry+inclination scenarios. The deprojection in question is performed by the non-parametric algorithm DOPING. The formalism is tested with model systems and then is applied to a sample of 24 clusters. While the ...

2008-01-01

365

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

366

Association of brain cancer with dental x-rays and occupation in Missouri  

International Nuclear Information System (INIS)

This investigation of a brain cancer cluster in Missouri used two approaches to investigate associations with potential risk factors. In a case-control study in a rural town, we interviewed surrogates of cases and controls about potential risk factors. We found a statistically significant positive association of brain cancer with reported exposure to dental x-rays. Occupation was not associated with the cluster in the rural town. In a standardized proportional mortality study for the state of Missouri, we calculated the observed and expected proportion of brain cancers by occupation and industry in Missouri decedents. We found that motor vehicle manufacturers, beauty shop workers, managers and administrators, elementary school teachers, and hairdressers and cosmetologists had significantly elevated proportions of brain cancer. Brain tumors are inconsistently associated with occupation in the literature. Further study of brain cancer etiology with respect to dental ...

1991-01-01

367

An X-ray photoelectron spectroscopic study of B-N-Ti system  

International Nuclear Information System (INIS)

Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.

1997-04-04

368

A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity  

International Nuclear Information System (INIS)

Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.

1988-01-14

369

XPS and STM study of passive films formed on Fe-22Cr(110) single-crystal surfaces  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy and ex situ scanning tunneling microscopy measurements have been combined to investigate the thickness, the chemical composition, and the structure of passive films formed in 0.5 M H{sub 2}SO{sub 4} on Fe-22Cr(110). Aging under polarization at +500 mV/SHE causes a dehydration (anodic) reaction of the outer chromium hydroxide layer of the passive film. This anodic reaction results in a thickening of the inner mixed Cr(III) and Fe(III) oxide layer enriched in Cr{sub 2}O{sub 3}. It also causes a coalescence of the oxide nuclei of the passive film and a crystallization of the inner Cr{sub 2}O{sub 3}. It also causes a coalescence of the oxide nuclei of the passive film and a crystallization of the inner Cr{sub 2}O{sub 3} oxide layer in epitaxy with the substrate. The epitaxial relationship is {alpha}-Cr{sub 2}O{sub 3}(0001) {parallel} Fe-22Cr(110) with three different azimuthal orientations. Aging under polarization ...

1996-04-01

370

Weakly-bridged dimeric diorganotin(IV) compounds derived from pyruvic acid hydrazone Schiff base ligands: Synthesis, characterization and crystal structures  

British Library Electronic Table of Contents (United Kingdom)

We report the synthesis of four diorganotin(IV) compounds of Schiff base pyruvic acid hydrazone derivatives formulated as [R2SnLY]2, where L1 is 2-SC4H3CON2C(CH3)CO2 with Y = CH3CH2CH2CH2OH, R = n-Bu (1); L2 is C6H5CON2C(CH3)CO2 with Y = CH3CH2OH, R = p-F-Bz (2); L3 is 2-HOC6H4CON2C(CH3)CO2 with YH2O, R = p-CN-Bz (3); and L4 is 4-NO2-C6H4CON2C(CH3)CO2 with YCH3CH2OH, R = Bz (4). The structures of all compounds have been established by a combination of single-crystal X-ray diffraction analysis, 1H and 119Sn NMR spectroscopy, IR spectroscopy, and elemental analysis. Studies reveal that four ligands present the same coordination mode with tin center, which all present tridentate ONO donor Schiff bases and coordinate to the tin center in an enolic form. In compounds 1-4, each tin atom is seven...

2011-01-01

371

The mechanism of metal nanoparticle formation in plants: limits on accumulation  

Energy Technology Data Exchange (ETDEWEB)

Metal nanoparticles have many potential technological applications. Biological routes to the synthesis of these particles have been proposed including production by vascular plants, known as phytoextraction. While many studies have looked at metal uptake by plants, particularly with regard to phytoremediation and hyperaccumulation, few have distinguished between metal deposition and metal salt accumulation. This work describes the uptake of AgNO{sub 3}, Na{sub 3}Ag(S{sub 2}O{sub 3}){sub 2}, and Ag(NH{sub 3}){sub 2}NO{sub 3} solutions by hydroponically grown Brassica juncea and the quantitative measurement of the conversion of these salts to silver metal nanoparticles. Using X-ray absorption near edge spectroscopy (XANES) to determine the metal speciation within the plants, combined with atomic absorption spectroscopy (AAS) for total Ag, the quantity of reduction of Ag{sup I} to Ag{sup 0} is reported. Transmission electron microscopy (TEM) ...

2009-08-15

372

The Structure of the Amyloid-[beta] Peptide High-Affinity Copper II Binding Site in Alzheimer Disease  

Energy Technology Data Exchange (ETDEWEB)

Neurodegeneration observed in Alzheimer disease (AD) is believed to be related to the toxicity from reactive oxygen species (ROS) produced in the brain by the amyloid-{beta} (A{beta}) protein bound primarily to copper ions. The evidence for an oxidative stress role of A{beta}-Cu redox chemistry is still incomplete. Details of the copper binding site in A{beta} may be critical to the etiology of AD. Here we present the structure determined by combining x-ray absorption spectroscopy (XAS) and density functional theory analysis of A{beta} peptides complexed with Cu{sup 2+} in solution under a range of buffer conditions. Phosphate-buffered saline buffer salt (NaCl) concentration does not affect the high-affinity copper binding mode but alters the second coordination sphere. The XAS spectra for truncated and full-length A{beta}-Cu{sup 2+} peptides are similar. The novel distorted six-coordinated (3N3O) geometry around copper in the A{beta}-Cu{sup ...

2008-11-03

373

Surface modification of PTFE sheet by synchrotron radiation in the soft X-ray region  

International Nuclear Information System (INIS)

Full text: The surface properties of poly (tetrafluoroethylene) (PTFE) are changed by the exposure to synchrotron radiation (SR). We succeeded in controlling the wettability of the PTFE surface from hydrophobic to hydrophilic by varying the substrate temperature during the SR irradiation and found that the wettability was ascribable to microstructure and chemical composition of surface.In these previous works, oxygen atoms were found to inhabit on the hydrophobic surface of PTFE. In this study, we investigated the surface modification of PTFE from the SR exposure experiment under the O_2 gas atmosphere. The SR exposure to the PTFE sheet was carried out at beamline 6 (BL6) of the New- SUBARU. The PTFE sheet was irradiated to the white beam, ranging 50-1000 eV at BL6 at room temperature. The gas cell was mounted at the irradiation chamber. The O_2 gas pressure in the gas cell can be maintained at about 0.20 Pa during the SR exposure using 5mm #phi# hole window. The wettability of PTFE ...

2004-07-19

374

Structure and property relationship in the mixed-conducting Sr-Fe-Co-O system.  

Energy Technology Data Exchange (ETDEWEB)

Mixed-conducting ceramic oxides have potential uses in high-temperature electrochemical applications such as solid oxide fuel cells, advanced batteries, sensors, and oxygen-permeable membranes. The Sr-Fe-Co-O system combines high electronic/ionic conductivity with appreciable oxygen permeability at elevated temperatures. Dense ceramic membranes made of this material can be used to separate high-purity oxygen from air without the need for external electrical circuitry, or to partially oxidize methane to produce syngas. Samples of Sr{sub 2}Fe{sub 3{minus}x}Co{sub x}O{sub y} (with x = 0, 0.6, 1.0, and 1.4) were prepared by solid-state reaction in atmospheres with various oxygen partial pressures (pO{sub 2}) and were characterized by X-ray diffraction, scanning electron microscopy, and electrical conductivity measurements. Phase components of the samples are dependent on cobalt concentration and synthesis pO{sub 2}. Total conductivity increases ...

1998-05-18

375

Structural and electrical characteristics of epitaxial CoSi{sub 2} grown on n-Si{sub 0.83}Ge{sub 0.17}/n-Si(001) by reactive chemical vapor deposition using a Si capping layer  

Energy Technology Data Exchange (ETDEWEB)

Epitaxial cobalt disilicide (CoSi{sub 2}) layers are grown on n-Si{sub 0.83}Ge{sub 0.17}/n-Si(001) using a sacrificial Si capping layer at the growth temperature T{sub s}=650 deg. C by reactive chemical vapor deposition using cyclopentadienyl dicarbonyl cobalt (Co({eta}{sup 5}-C{sub 5}H{sub 5})(CO){sub 2}). Structural and electrical properties of epi-CoSi{sub 2}/Si{sub 0.83}Ge{sub 0.17}/Si(001) were measured by transmission electron microscopy, X-ray diffraction, Auger electron spectroscopy and sheet resistance measurement as a function of annealing temperature. The combined results showed that the epitaxial CoSi{sub 2} phase by the reaction of Co with the Si capping layer was formed in the as-grown layers. Rapid thermal anneals for the investigation of thermal stability of the as-grown layers showed good thermal stability of the epitaxial CoSi{sub 2} layers with the low sheet resistance value as low as congruent with 4.4 {omega}/cm up to the ...

2004-06-30

376

Structural and electrical characteristics of epitaxial CoSi_2 grown on n-Si_0_._8_3Ge_0_._1_7/n-Si(001) by reactive chemical vapor deposition using a Si capping layer  

International Nuclear Information System (INIS)

Epitaxial cobalt disilicide (CoSi_2) layers are grown on n-Si_0_._8_3Ge_0_._1_7/n-Si(001) using a sacrificial Si capping layer at the growth temperature T_s=650 deg. C by reactive chemical vapor deposition using cyclopentadienyl dicarbonyl cobalt (Co(#eta#"5-C_5H_5)(CO)_2). Structural and electrical properties of epi-CoSi_2/Si_0_._8_3Ge_0_._1_7/Si(001) were measured by transmission electron microscopy, X-ray diffraction, Auger electron spectroscopy and sheet resistance measurement as a function of annealing temperature. The combined results showed that the epitaxial CoSi_2 phase by the reaction of Co with the Si capping layer was formed in the as-grown layers. Rapid thermal anneals for the investigation of thermal stability of the as-grown layers showed good thermal stability of the epitaxial CoSi_2 layers with the low sheet resistance value as low as congruent with 4.4 #OMEGA#/cm up to the annealing temperature as high as 850 deg. C without ...

2004-06-30

377

Structural Analysis for Gold Mineralization Using Remote Sensing and Geochemical Techniques in a GIS Environment: Island of Lesvos, Hellas  

International Nuclear Information System (INIS)

Exploration for epithermal Au has been active lately in the Aegean Sea of the eastern Mediterranean Basin, both in the islands of the Quaternary arc and in those of the back-arc region. The purpose of this study was the structural mapping and analysis for a preliminary investigation of possible epithermal gold mineralization, using remotely sensed data and techniques, structural and field data, and geochemical information, for a specific area on the Island of Lesvos. Therefore, Landsat-TM and SPOT-Pan satellite images and the Digital Elevation Model (DEM) of the study area were processed digitally using spatial filtering techniques for the enhancement and recognition of the geologically significant lineaments, as well as algebraic operations with band ratios and Principal Component Analysis (PCA), for the identification of alteration zones. Statistical rose diagrams and a SCHMIDT projection Stereo Net were generated from the lineament maps and the collected field data (dip and strike ...

2000-12-01

378

Raman spectroscopic studies of carbon in extra-terrestrial materials  

International Nuclear Information System (INIS)

The measurements obtained here indicate ways in which micro-Raman spectroscopy can be used to elucidate structural characteristics and distribution of carbon in meteorites and interplanetary dust particles (IDPs). Existing information about structurally significant aspects of Raman measurements of graphite is combined with structurally relevant findings from the present micro-Raman studies of carbons prepared by carbonization of polyvinylidine chloride (PVDC) at various temperatures and natural material, as well as several acid residues from the Allende and Murchison meteorites in order to establish new spectra-structure relationships. Structural features of many of the materials in this study have been measured by x ray analysis and electron microscopy: thus, their structural differences can be directly correlated with differences in the Raman spectra. The spectral parameters consequently affirmed as indicators of ...

1990-04-01

379

Quantification of the incorporation coefficient of a reactive gas on a metallic film during magnetron sputtering: The method and results  

International Nuclear Information System (INIS)

Reactive Magnetron Sputtering is a complex process and huge efforts are made addressing the understanding of its fundamental phenomena and the simulation of the deposition process by e.g. Particle in Cell/Monte Carlo (PIC/MC). One of the most uncertain parameters in this reactive sputtering process is the incorporation coefficient of the reactive gas in the growing layer, i.e. the real-time sticking coefficient during deposition. In this work, mass spectrometry is used to deliver more insights on this complex matter. Earlier, a method was developed to determine the incorporation coefficient of the reactive gas molecules in the growing metal film, using mass spectrometry combined with thin film analysis techniques (electron probe microanalysis and x-ray photoelectron spectroscopy). This method delivers a global, realistic incorporation coefficient which can be used in models for the reactive sputtering process. In this work, new insights have ...

2009-12-31

380

Preparation and electrochemical investigation of Li{sub 2}CoPO{sub 4}F cathode material for lithium-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we report the electrochemical characteristics of a novel cathode material, Li{sub 2}CoPO{sub 4}F, prepared by solid-state reactions. The solid-state reaction mechanism involved in synthesizing the Li{sub 2}CoPO{sub 4}F also is analyzed in this paper. When cycled between 2.0 V and 5.0 V during cyclic voltammetry measurements, the Li{sub 2}CoPO{sub 4}F samples present one, fully reversible anodic reaction at 4.81 V. When cycled between 2.0 V and 5.5 V, peaks occurring at 4.81 V and 5.12 V in the first anodic scan evolved to one broad oxidative, mound-like pattern in subsequent cycles. Correspondingly, the X-ray diffraction (XRD) pattern of the Li{sub 2}CoPO{sub 4}F electrode discharged from 5.5 V to 2.0 V is slightly different from the patterns exhibited by a fresh sample and the sample discharged from 5.0 V to 2.0 V. This difference may correspond to a structural relaxation that appears above 5 V. In the constant current cycling measurements, the ...

2011-02-15

381

Oxygen plasma treatment and deposition of CN_x on a fluorinated polymer matrix composite for improved erosion resistance  

International Nuclear Information System (INIS)

The use of polymer matrix composites in aerospace propulsion applications is currently limited by insufficient resistance to erosion by abrasive media. Erosion resistant coatings may provide necessary protection; however, adhesion to many high temperature polymer matrix composite (PMC) materials is poor. A low pressure oxygen plasma treatment process was developed to improve adhesion of CN_x coatings to a carbon reinforced, fluorinated polymer matrix composite. Fullerene-like CN_x was selected as an erosion resistant coating for its high hardness-to-elastic modulus ratio and elastic resilience which were expected to reduce erosion from media incident at different angles (normal or glancing) relative to the surface. In situ x-ray photoelectron spectroscopy was used to evaluate the effect of the plasma treatment on surface chemistry, and electron microscopy was used to identify changes in the surface morphology of the PMC substrate after plasma exposure. The fluorine ...

2007-07-01

382

Optimizing the radiosensitive liquid-core microcapsules for the targeting of chemotherapeutic agents  

Energy Technology Data Exchange (ETDEWEB)

Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core was 10.2 {+-} 4.3 ...

2007-07-15

383

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area source when ...

2003-03-04

384

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. tensile experiment. Samples with 0 degree, 45 ...

385

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed ...

386

Electrochemical and surface analytical studies of the interaction of nitrogen with key alloying elements in stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Surface analytical studies of high nitrogen austenitic stainless steels exposed to deaerated 0.1M HCl have revealed that nitrogen alloying additions influence the composition of salt layers and the passive film/alloy interface. In this study the authors employ electrochemical techniques and variable angle X-ray Photoelectron Spectroscopy (XPS) to examine the passive films formed on a series of austenitic stainless steels, Fe18Cr8Ni, Fe18Cr8Ni0.2N, Fe20Cr20Ni, Fe20Cr20Ni6Mo and Fe20Cr20Ni6Mo0.2N, in acidic chloride aqueous solution. In addition, several other model alloys, Fe19Cr, Fe19Cr9Ni, Fe19Cr2.5Mo, and Fe19Cr9Ni2.5Mo, were examined before and after electrochemical surface nitriding, a technique proven to have an effect analogous to N alloying. It was shown that nitrogen, nickel and molybdenum additions independently and in certain combinations stimulate selective dissolution of iron, resulting in a significant enrichment of chromium ...

1995-12-01

387

Electrochemical and surface analytical studies of the interaction of nitrogen with key alloying elements in stainless steels  

International Nuclear Information System (INIS)

Surface analytical studies of high nitrogen austenitic stainless steels exposed to deaerated 0.1M HCl have revealed that nitrogen alloying additions influence the composition of salt layers and the passive film/alloy interface. In this study the authors employ electrochemical techniques and variable angle X-ray Photoelectron Spectroscopy (XPS) to examine the passive films formed on a series of austenitic stainless steels, Fe18Cr8Ni, Fe18Cr8Ni0.2N, Fe20Cr20Ni, Fe20Cr20Ni6Mo and Fe20Cr20Ni6Mo0.2N, in acidic chloride aqueous solution. In addition, several other model alloys, Fe19Cr, Fe19Cr9Ni, Fe19Cr2.5Mo, and Fe19Cr9Ni2.5Mo, were examined before and after electrochemical surface nitriding, a technique proven to have an effect analogous to N alloying. It was shown that nitrogen, nickel and molybdenum additions independently and in certain combinations stimulate selective dissolution of iron, resulting in a significant enrichment of chromium ...

1995-03-26

388

Effects of pH and phosphate on metal distribution with emphasis on As speciation and mobilization in soils from a lead smelting site  

Energy Technology Data Exchange (ETDEWEB)

Arsenic in soils from the Asarco lead smelter in East Helena, Montana was characterized by X-ray absorption spectroscopy (XAS). Arsenic oxidation state and geochemical speciation were analyzed as a function of depth (two sampling sites) and surface distribution. These results were compared with intensive desorption/dissolution experiments performed in a pH stat reactor for samples from the site with the highest degree of As heterogeneity. The objectives of the study were to investigate the solid-phase geochemical As speciation, assess the speciation of As in solutions equilibrated with the solids under controlled pH (pH=4 or 6) and Eh (using hydrogen or air) environments, observe the effects of phosphate on the release of As into solution, and examine the effects of phosphate on metal mobility in the systems. Arsenic was predominantly found in the As(V) valence state, though there was evidence that As(III) and As(0) were present also. The dominant geochemical phase ...

2005-06-01

389

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the spent electron beam coming from the VUV FEL which allows one to significantly extend ...

2001-12-21

390

Correlating microstructure and thermal transport of irradiated SiC  

International Nuclear Information System (INIS)

Full text of publication follows: The effect of neutron irradiation on the thermal conductivity of silicon carbide can be dramatic depending on the irradiation temperature and fluence the material is subjected to, and may be a critical factor defining it's use in fusion systems. Historically there have been several papers describing the effect of neutron irradiation on thermal conductivity degradation of SiC, predominately in the low to intermediate temperature ranges. Practically all of this work has been at temperatures lower than the application temperature for SiC being considered by the conceptual fusion reactors. This paper provides new data on the thermal conductivity of high quality CVD silicon carbide irradiated in a range of doses and temperature spanning the proposed fusion reactor temperature range. Specifically, an irradiation was carried out from fractions milli-dpa to approximately 8 dpa in the HFIR with irradiation temperatures ranging from 80-1600 deg. C. Results of ...

2007-12-10

391

Characterization of TiN coatings deposited on plasma nitrided tool steel surfaces  

Energy Technology Data Exchange (ETDEWEB)

Wear-resistant TiN coatings deposited on tool steels are used frequently in industry. There is a trend towards further optimizing these coatings, e.g. by plasma nitriding the tool surface prior to TiN deposition. In this work the influence of the nitriding conditions on the surface properties of AISI 304 and ASP 23 tool steels was investigated. The plasma nitriding was carried out in a triode ion plating configuration normally used to deposit TiN coatings. At the surface of AISI 304 stainless steel, only a thin compound layer (Fe{sub 4}N, Fe{sub 3}N) was found, probably as a consequence of the rather slow nitrogen diffusion in the austenite matrix. For ASP 23 high speed steel, the different nitriding behaviour of the martensitic matrix causes the formation of a diffusion layer which results in an increase in hardness at the surface. On an analogous set of specimens the TiN deposition was started immediately after the plasma nitriding. To optimize this combined ...

1991-07-07

392

Application of Bayer red mud for iron recovery and building material production from alumosilicate residues  

Energy Technology Data Exchange (ETDEWEB)

Red mud is a solid waste produced in the process of alumina extraction from bauxite. In this paper, recovery iron from Bayer red mud was studied with direct reduction roasting process followed by magnetic separation, and then building materials were prepared from alumosilicate residues. After analysis of chemical composition and crystalline phase, the effects of different parameters on recovery efficiency of iron were carried out. The optimum reaction parameters were proposed as the following: ratio of carbon powder: red mud at 18:100, ratio of additives: red mud at 6:100, roasting at 1300 deg. C for 110 min. With these optimum parameters, total content of iron in concentrated materials was 88.77%, metallization ratio of 97.69% and recovery ratio of 81.40%. Then brick specimens were prepared with alumosilicate residues and hydrated lime. Mean compressive strength of specimens was 24.10 MPa. It was indicated that main mineral phase transformed from nepheline (NaAlSiO{sub 4}) in ...

2009-01-15

393

A combinatorial library of micro-topographies and chemical compositions for tailored surface wettability  

Energy Technology Data Exchange (ETDEWEB)

Surface modification of topography and chemistry in order to achieve a specific water contact angle (CA) has been explored by using a novel combinatorial screening platform. The screening arrays consisted of 507 distinct combinations of micro-topographies and chemical compositions. By performing chemical modifications with 1H, 1H, 2H, 2H perfluoroethyltriethoxy-silane (PFS) and n-octadecyltriethoxysilane (ODS) on standard silicon wafers it was possible to include both superhydrophobic and very hydrophilic pad arrays in the same screening platform. Surfaces modified with PFS were more hydrophobic than surfaces modified with ODS, while the unmodified silicon surfaces were hydrophilic. For the PFS modified surfaces the largest CAs were achieved with a small pillar size of X = 1 {mu}m and an intermediate inter-pillar gap size of Y = 4 {mu}m with superhydrophobic CAs over 170 . Surface analysis with X-ray photoelectron spectroscopy (XPS) revealed ...

2011-06-15

394

The correlation between accelerated and field corrosion tests performed in carbon steel and weathering steel coupons, coated and non-coated; Correlacao entre ensaios acelerados e ensaios de campo em corpos-de-provas de aco carbono e aco patinavel, sem e com revestimento  

Energy Technology Data Exchange (ETDEWEB)

The performance of four different organic coating systems applied to carbon and weathering steel coupons has been assessed in this investigation. applied on the surface of carbon steel and weathering steel coupons. The coupons have been evaluated using five different tests, three field tests and two accelerated tests. The field tests were carried out at three atmospheric stations, located at COSIPA in Cubatao-SP, at Alto da Serra in Cubatao-SP and at Paula Souza in Sao Paulo city. The accelerated tests consisted of (a) exposure to alternate cycles of ultraviolet radiation/condensation combined with salt spray cycles (UVCON combined with Salt Spray) and of (b) exposure to alternate cycles of ultraviolet radiation/condensation combined with the Prohesion test. The performance of the coatings was assessed by visual observation and photographs, using a method based on ASTM D-610, ASTM D-714 and ASTM-1654 standards to rank them. ...

2002-07-01

395

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

396

X-ray structure of sensory rhodopsin II at 2.1-? resolution  

UK PubMed Central (United Kingdom)

Sensory rhodopsins (SRs) belong to a subfamily of heptahelical transmembrane proteins containing a retinal chromophore. These photoreceptors mediate the cascade of vision in animal eyes and phototaxis...Full Text Available

2001-08-28

397

X rays in molecular biophysics  

Energy Technology Data Exchange (ETDEWEB)

An atom-by-atom understanding of life processes is emerging from a flurry of experiments fueled by synchrotron sources and DNA technology. {copyright} 1995 {ital American} {ital Institute} {ital of} {ital Physics}.

1995-11-01

398

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...

2010-01-28

399

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, ...

2010-06-01

400

Valence electronic structure of Ni in Ni-Si alloys from relative K X-ray intensity studies  

Energy Technology Data Exchange (ETDEWEB)

The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal alloys.

2007-02-15

401

Using X-ray Microscopy and Hg L3 XANES to study Hg Binding in the Rhizosphere of Spartina Cordgrass  

UK PubMed Central (United Kingdom)

San Francisco Bay has been contaminated historically by mercury from mine tailings as well as contemporary industrial sources. Native Spartina foliosa and non-native S....Full Text Available

2009-10-01

402

Theoretical modelling of X-ray fluorescence signals for different lunar compositions and dependence on solar activity  

British Library Electronic Table of Contents (United Kingdom)

We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-ray induced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...

2010-01-01

403

The inhomogeneous structure of water at ambient conditions  

UK PubMed Central (United Kingdom)

Small-angle X-ray scattering (SAXS) is used to demonstrate the presence of density fluctuations in ambient water on a physical length-scale of ≈1 nm; this is retained with decreasing temperature...Full Text Available

2009-09-08

404

The Orbit of the Eclipsing X-ray Pulsar EXO 1722-363  

CERN Document Server

With recent and archival Rossi X-Ray Timing Explorer (RXTE) X-ray measurements of the heavily obscured X-ray pulsar EXO 1722-363 (IGR J17252-3616), we carried out a pulse timing analysis to determine the orbital solution for the first time. The binary system is characterized by a_x sin(i) = 101 +/- 3 lt-s and P_orb = 9.7403 +/- 0.0004 days (90% confidence), with the precision of the orbital period being obtained by connecting datasets separated by more than 7 years (272 orbital cycles). The orbit is consistent with circular, and e 61 degrees at the 99% confidence level, the radius of the primary is between 21 R_sun and 37 R_sun, and its mass is less than about 22 M_sun. The acceptable range of radius and mass shows that the primary is probably a supergiant of spectral type B0I-B5I. Photometric measurements of its likely counterpart are consistent with the spectral type and luminosity if the distance to the system is ...

2006-01-01

405

The DEXD/H-box RNA Helicase DDX19 Is Regulated by an ?-Helical Switch*S?  

UK PubMed Central (United Kingdom)

DEXD/H-box RNA helicases couple ATP hydrolysis to RNA remodeling by an unknown mechanism. We used x-ray crystallography and biochemical analysis of the human DEXD/H-box...Full Text Available

2009-04-17

406

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

407

Temperature Dependence of Structure, Bending Rigidity, and Bilayer Interactions of Dioleoylphosphatidylcholine Bilayers  

UK PubMed Central (United Kingdom)

X-ray diffuse scattering was measured from oriented stacks and unilamellar vesicles of dioleoylphosphatidylcholine lipid bilayers to obtain the temperature dependence of the structure and of the material...Full Text Available

2008-01-01

409

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be ...

2001-04-01

410

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to ...

2001-04-01

411

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

412

Structure of molten alkali halides  

Energy Technology Data Exchange (ETDEWEB)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-06-01

413

Structure of molten alkali halides  

International Nuclear Information System (INIS)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-01-01

414

Structural transformations in heat-resistant protective coatings on nickel alloys  

Energy Technology Data Exchange (ETDEWEB)

In this work a comprehensive metallophysical study was carried out for two aluminosilicide slip coatings of the systems Al-Si and Al-Nb-Si and an electron-beam Co-Cr-Al-Y coating on alloy EP-539 (17...19% Cr, 4...6% Co, 2.5...4% W, 4.5...6.5% Mo, 2...3% Ti, 3...4% Al, 1.4...2% Nb, balance Ni) after high-temperature testing. The protective properties of the coatings were evaluated from the results of laboratory tests for heat resistance at 1000/sup 0/C in the combustion products of diesel fuel with added sulfur at 970, 1000, and 1060/sup 0/C for 100 h and after full-scale tests for 150, 250, 400, and 700 h. Metallographic, hardness, x-ray, and micro x-ray studies of the coating were carried out. Layer-by-layer phase composition and the lattice spacing of the main phases were determined. X-ray analysis was carried out in an a DRON-1 diffractometer in copper K/sub ..-->../-radiation, and x-ray ...

1987-09-01

415

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

416

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

417

Probing the Origins of the CIV and Fe Kalpha Baldwin Effect  

CERN Document Server

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft ...

2009-01-01

418

Preliminary X-ray crystallographic studies of Bacillus subtilis SpeA protein  

UK PubMed Central (United Kingdom)

The speA gene in Bacillus subtilis encodes arginine decarboxylase, which catalyzes the conversion of arginine to agmatine. Arginine decarboxylase is an important enzyme...Full Text Available

419

Phase, residual stress, and texture in triode-sputtered tantalum coatings on steel. Final report  

Energy Technology Data Exchange (ETDEWEB)

This work analyzes the unoptimized prototype triode-sputtered, 150 microns thick tantalum coatings deposited with a 2.5 microns niobium underlayer on the bore of a large-diameter A723 steel cylinder. The coating was deposited for wear and erosion protection by Pacific Northwest National Laboratory. The phase determination was based on X ray diffraction analysis, wavelength dispersive X ray fluorescence analysis, energy dispersive X ray analysis, and hardness and electrical resistivity measurements. Both X ray diffraction and radius-of- curvature methods were used to determine residual stresses. A locally developed high-resolution pole figure technique was used to perform texture analysis. The post-firing, debonded coating showed alpha-tantalum, preferred 110 orientation, high surface stresses, tantalum oxides, entrapped ...

1998-07-01

420

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...

421

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.

1999-03-01

422

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

423

Molecular conformation, receptor binding, and hormone action of natural and synthetic estrogens and antiestrogens.  

UK PubMed Central (United Kingdom)

The X-ray crystallographic structural determinations of synthetic estrogens and antiestrogens provide reliable information on the global minimum energy conformation of these molecules or a local minimum...Full Text Available

1985-09-01

424

Molar extinction coefficients of some biologically important substances  

International Nuclear Information System (INIS)

Reliable values of x-ray and gamma-ray attenuation coefficients of elements and compounds are required in spectrometry as well as in many other scientific, engineering and medical disciplines involving photon radiation

2002-11-15

425

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

426

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

2008-05-22

427

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

428

Localization of gold in synovial membrane of rheumatoid arthritis treated with sodium aurothiomalate. Studies by electron microscope and electron probe x-ray microanalysis.  

UK PubMed Central (United Kingdom)

The localization of gold in the synovial membrane of rheumatoid arthritis patients treated with sodium aurothiomalate was examined and quantitative analysis of epon-embedded sections was carried out...Full Text Available

1977-06-01

429

Localization and Toxic Effects of Cadmium, Copper, and Uranium in Azolla1  

UK PubMed Central (United Kingdom)

The storage and distribution of copper, cadmium, and uranium and their effects on ionic contents in roots and shoots of Azolla filiculoides has been studied by x-ray microanalysis....Full Text Available

1988-09-01

430

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication ...

1992-10-01

431

Ion-induced M X-ray emission from heavy lanthanides  

Energy Technology Data Exchange (ETDEWEB)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.

1987-12-01

432

Investigation of anomalous CXR response of filled cables  

Energy Technology Data Exchange (ETDEWEB)

An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.

1982-12-01

433

Investigating the complex X-ray spectrum of a broad-line 2MASS red quasar: XMM-Newton observation of FTM 0830+3759  

CERN Document Server

We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of sight to the nucleus and a Compton reflection ...

2010-01-01

434

Interaction of x-rays and food pyrolysis products in producing oncogenic transformation in vitro  

International Nuclear Information System (INIS)

In recent years it has become evident from epidemiological and experimental data that a large number of environmental factors, including diet, play a role in modifying the incidence of cancer. Cell culture systems in which oncogenic transformation serves as an end point are powerful tools for evaluating these questions. Using such systems it has been shown recently that pyrolysis products from charred surfaces of broiled meat and fish can transform hamster embryo cells in vitro as well as produce tumors in the animal. Our studies in vitro have demonstrated the oncogenic potential of ionizing radiation in both hamster and human cells and have established in hamster cells the dose response relationship at doses ranging from 1 to 600 rad for x-rays and 0.1 to 150 rad for neutrons. The present work was aimed at evaluating whether there exists a cocarcinogenic interaction between a pyrolysis product and x-rays in their ability to transform hamster ...

1981-07-01

435

Inelastic x-ray scattering of dense solid oxygen: Evidence for intermolecular bonding  

UK PubMed Central (United Kingdom)

The detailing of the intermolecular interactions in dense solid oxygen is essential for an understanding of the rich polymorphism and remarkable properties of this element at high pressure. Synchrotron...Full Text Available

2008-08-19

436

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

437

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.

2003-05-15

438

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

439

Electronic spectra of semiconductor nanocrystals  

Energy Technology Data Exchange (ETDEWEB)

Semiconductor nanocrystals smaller than the bulk exciton show substantial quantum confinement effects. Recent experiments including Stark effect, resonance Raman, valence band photoemission, and near edge X-ray adsorption will be used to put together a picture of the nanocrystal electronic states.

1993-12-31

440

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

441

Determination of size distribution of Guinier-Preston zones in Al-Ag alloys by small-angle x-ray scattering method  

International Nuclear Information System (INIS)

Small-angle X-ray scattering method recognised to be very useful in the studies of structural problems of materials in homogeneous in nanoscale. Studies by small-angle X-ray scattering on the Al-Ag alloys are presented. The size distributions of spherical Guinier-Person zones were calculated using Vonk's and Glatter's methods. Small-angle X-ray scattering studies were performed on Al-5.0 at.%Ag alloy containing Guinier-Preson zones in the #eta#-state. For this alloy one can assume that scattering particles are of spherical shape, have uniform electron density and scatter independently. Moreover, the size distributions were calculated for Al-1.6 at.%Ag alloy containing Guinier-Preston zones in #epsilon#-state (scattering particles with not uniform electron density). Both, Vonk's and Glatter's, methods gave similar size distributions. Profiles of size distributions for Guinier-Preston zones in #epsilon#-state are more complex ...

2001-09-23

443

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values.

1984-01-20

444

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

International Nuclear Information System (INIS)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values. (author).

1984-01-01

445

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

446

Crystallization and preliminary X-ray analysis of human liver ?-enolase  

UK PubMed Central (United Kingdom)

Enolase is a multifunctional enzyme that plays important roles in many biological and disease processes. α-Enolase from human liver (hENO1) was expressed as a soluble protein and purified by...Full Text Available

447

Crystal structure of the human adenovirus proteinase with its 11 amino acid cofactor.  

UK PubMed Central (United Kingdom)

The three-dimensional structure of the human adenovirus-2 proteinase complexed with its 11 amino acid cofactor, pVIc, was determined at 2.6 A resolution by X-ray crystallographic analysis. The fold...Full Text Available

1996-04-15

448

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the interferometric microscope. ...

2005-07-12

449

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the interferometric microscope. ...

2005-04-17

450

Coupling of Pressure-Induced Structural Shifts to Spectral Changes in a Yellow Fluorescent Protein  

UK PubMed Central (United Kingdom)

AbstractX-ray diffraction analysis of pressure-induced structural changes in the Aequorea yellow fluorescent protein Citrine reveals the structural basis for the continuous...Full Text Available

2009-09-16

451

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-08-01

452

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that FCR is equal to FS ...

1995-01-01

453

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

454

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

455

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

456

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

457

A Distinctive Disk-Jet Coupling in the Seyfert-1 AGN NGC 4051  

CERN Document Server

We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this relation by more than 11 sigma, indicating ...

2010-01-01

458

Hydration of swelling clay and bacteria interaction. An experimental in situ reaction study; Hydratation des argiles gonflantes et influence des bacteries. Etude experimentale de reaction in situ  

Energy Technology Data Exchange (ETDEWEB)

This study reports on the physical-chemical behaviour of swelling di-octahedral clays (smectites) and their interaction with aqueous solutions and bacteria (Shewanella putrefaciens). Experimental results are presented for compacted clays, hydrated under confined volume conditions, using a new type of reaction-cell (the 'wet-cell' of Warr and Hoffman, 2004) that was designed for in situ X-ray diffraction (XRD) measurement. For comparison, dispersed clay systems were studied using standard batch solutions subjected to varying degrees of agitation. The combination of time-dependent in situ XRD measurements with gravimetric measurements and calculated diffraction patterns using the CALCMIX software (Plancon and Drits, 1999) allowed to successful quantification of the dynamics of water uptake and storage. This analytical procedure combined with published water vapour adsorption data enabled determination of the ...

2008-01-15

459

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

460

X-ray observation of a. sqrt. 3 x. sqrt. 3 superlattice in KC/sub 8/ at high pressure  

Energy Technology Data Exchange (ETDEWEB)

A single-crystal x-ray study under pressure reveals a phase transition from an in-plane 2x2 commensurate potassium superstructure to a new ..sqrt..3x..sqrt..3 commensurate superstructure. This is the first such transition to be observed; it is related to the recently discovered staging transition of KC/sub 8/ under pressure. In addition this staging transition was observed to occur more slowly and at much lower pressures than in the reported neutron-scattering experiment on highly oriented pyrolytic graphite samples. 13 references, 2 figures.

1985-05-15

461

X-ray diffraction evaluation of the structural perfection of cadmium telluride single crystals  

Science.gov (United States)

A high degree of structural perfection is an essential requirement for CdTe crystals used as substrates for the epitaxial growth of CdHgTe alloys. Here, a method for the evaluation of the structural perfection of CdTe crystals is proposed which is based on X-ray diffraction measurements using both two-crystal and three-crystal diffractometers (differential version). The method makes it possible to obtain more information on structural perfection both at the crystal surface and within the crystal body.

1988-08-01

462

Use of X-ray fluorescence analysis in the study of archeological samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (XFA) was used in the determination of the contents of metal residues in dosing plates for coin minting. XFA was also used for the determination of the strontium/calcium ratio in bone samples of different animals with the aim to obtain information on the food composition of these animals. It was found that bones of different animals can be distinguished based on the Sr/Ca ratio. No significant differences in the Sr/Ca ratio were observed in human bones of individuals from different social groups. (author). 1 fig., 5 tabs., 4 refs.

1988-09-26

463

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

464

The use of x-ray fluorescence in the detection of inorganic elements in medicines drugs  

International Nuclear Information System (INIS)

Based on the instrumental wavelength dispersive X-ray fluorescence technique of analysis (W D-X R F), the inorganic elements in four samples of commercial medicines drugs were analyzed. The samples were used without any chemical separation of the elements or chemical pre-treatment. Eleven elements could be identified, namely Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu and Zn. However, Si, Ti and Mn have not been mentioned in the printed instructions for the use of the medicines drugs by the producers. (author)

465

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

466

The relative X-ray intensity Ksub(#alpha#)/Ksub(#beta#) of 3d elements by photoionization and electron capture  

International Nuclear Information System (INIS)

The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).

1981-03-19

467

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

468

Sunyaev-Zel'dovich Effects from Quasars Shining in Galaxies and Groups  

CERN Document Server

The energy fed by active galactic nuclei to the surrounding diffuse baryons changes the latter's amount, temperature, and distribution; so in groups and in member galaxies it affects the X-ray luminosity and also the Sunyaev-Zel'dovich effect. Here we compute how the latter is enhanced by the transient blastwave driven by a shining quasar, and is depressed when the equilibrium is recovered with a depleted density. We constrain such depressions and enhancements with the masses of relic black holes in galaxies and the X-ray luminosities in groups. We discuss how all these linked observables can tell the quasar contribution to the thermal history of the baryons pervading galaxies and groups.

2003-01-01

469

Structural, Vibrational and Mechanical Studies of Hydroxyapatite produced by wet-chemical methods  

CERN Document Server

Hydroxyapatite samples were produced by two different wet-chemical methods, and characterized by x-ray diffraction, infrared and compression strength measurements. The x-ray diffraction measurements were simulated using the Rietveld method, and structural data as lattice parameters and average crystallite size were obtained. The infrared spectra showed the presence of CO$_3^{2-}$ ions in all samples, indicating a contamination by these ions. By mixing samples produced by both methods, a bioceramic was obtained and, after sintering, samples with very high compression strengths (26--30 MPa) were obtained.

2004-01-01

470

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.

1983-01-01

471

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

472

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

473

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

474

ROSAT observations of the RSCVn binary sigma Geminorum  

DEFF Research Database (Denmark)

X-ray observations of the RSCVn system sigma Geminorum have been undertaken with the ROSAT observatory. Several spectra of very good signal-to-noise ratio were obtained. Spectral fitting using metal abundances amounting to 50% of solar values reveal two temperature components at 2 MK and 12 MK. Previous EXOSAT observations showed another component at 40 MK. Particular interest is focused on the temporal variations of the X-ray emission. It is found that variations occur on time scales ranging from years to hours and minutes.

1997-01-01

475

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

476

Provenance study of excavated pottery from Beirut using PIXE cluster analysis  

International Nuclear Information System (INIS)

The study of imported ceramics found in Beirut and suspected to belong to north Syrian products will provide key evidence for the roles in trade of the various postulated centers in northern Syria and northern Lebanon. It is proposed that a comprehensive range of likely north Syrian products imported to Beirut will be chemically analyzed by PIXE (proton induced X-ray emission) in order to characterize, compare and isolate the various regional production centers that supplied the city from the Persian to Byzantine periods. In this work, we were mainly focusing on the characterization of Amrit products, by using 3 MeV proton beam and Al funny filter, as X-ray absorber.

2006-08-01

477

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

478

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

479

Nanostructure of thin gold films investigated by means of atomic force microscopy and X-ray reflectometry methods  

International Nuclear Information System (INIS)

A study of the thin gold film growth, during the deposition on glass substrate under UHV conditions at low temperatures, is presented. The complementary methods, the atomic force microscopy and grazing incidence x-ray reflectometry, are used for the research. It is shown that due to variation of the time of deposition from 2 to 50 min different kinds of thin Au films nanostructures are obtained: from discontinuous films consisting of isolated islands, via formation of the chains of islands, up to continuous films. (author)

2001-09-23

480

Measurement of AlP/GaP (001) heterojunction band offsets by x-ray photoemission spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoemission spectroscopy has been used to measure the valence band offset {Delta}E{sub v} for the AlP/GaP (001) heterojunction interface. The heterojunction samples were prepared by molecular-beam epitaxy. A value of {triangle}E{sub v}=0.43 eV is obtained (staggered band alignment, with AlP valence band below that of GaP). 24 refs., 8 figs., 1 tab.

1993-07-01

481

LCLS XTOD Tunnel Vacuum System (XVTS)  

Energy Technology Data Exchange (ETDEWEB)

The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.

2005-11-04

482

K_#beta#/K_#alpha# X-ray intensity ratio following K-electron capture and radioisotope excitation  

International Nuclear Information System (INIS)

The K_#beta#/K_#alpha# X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49<=Z<=82 following electron capture decay and photon excitation using "2"4"1Am and "5"7Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K_#beta#/K_#alpha# values on the mode of excitation in the case of Mn and Fe is attribuited to the chemical effects, while no such dependence is found for the high-Z elements.

1987-01-01

483

Identification of elements in plant drugs and their water infusion using X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.

8100-01-01

484

Evidence for excess vacancy defects in the Pd-Si system: positron annihilation, x-ray diffraction and Auger electron spectroscopy study  

Energy Technology Data Exchange (ETDEWEB)

The transformation of Pd/Si to Pd{sub 2}Si/Si is investigated using depth-resolved positron annihilation, x-ray diffraction and Auger electron spectroscopy studies. The observed defect-sensitive positron S-parameter value of 1.022-1.054 indicates the existence of divacancies across the silicide/silicon interface and Si substrate region. Our experimental observation of vacancy defects is consistent with the model proposed for excess vacancy generation across the interface consequent to Si diffusion. (letter to the editor)

2003-11-26

485

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

486

Dual-energy projection radiography using condenser discharge x-ray generator and FCR. Determination of technical factors  

Energy Technology Data Exchange (ETDEWEB)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.

1987-04-01

487

Dual-energy projection radiography using condenser discharge x-ray generator and FCR  

International Nuclear Information System (INIS)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).

1987-01-01

488

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/  

International Nuclear Information System (INIS)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

489

Differential anomalous-x-ray-scattering study of icosahedral and amorphous Pd/sub 58. 8/U/sub 20. 6/Si/sub 20. 6/  

Energy Technology Data Exchange (ETDEWEB)

The total and differential atomic pair-correlation functions of an icosahedral (quasicrystalline) solid were determined for the first time, directly by the differential anomalous-x-ray-scattering technique using synchrotron radiation. The observed atomic distances involving uranium atoms in icosahedral Pd/sub 58.8/U/sub 20.6/Si/sub 20.6/ suggest the presence of a quasicrystalline sublattice with vertex decoration. The pair distribution functions in the icosahedral and amorphous phases are similar up to the second-nearest neighbors, or up to 6 A-circle.

1986-07-07

490

Determination of concentration distribution of admixtures by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A theoretical analysis is presented for the method of determining the concentration distribution of admixtures in zone melting and in the study of diffusion in melts. Continuous mode X-ray fluorescence analysis is considered. The convolution integral interpreting the analog output of the ratemeter was solved applying the mathematical apparatus of Z transformation. The feasibility of the method is tested on an example of the determination of tin distribution in tungsten. With respect to the statistical error (#delta#<1.5%), the maximum integration constant (100 s) and a very slow sample feed (0.025 mm/s) were used. The calculated transfer function reflects the total transfer function of the ratemeter and the recorder used. (M.D.).

1985-01-01

491

Determination of Mn, Fe, Cu, Zn, and Pb in particulate matter, raw and final materials of a brick factory by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.

1994-01-01

492

Core localized toroidal Alfven eigenmodes destabilized by energetic ions in the CHS heliotron/torsatron  

Energy Technology Data Exchange (ETDEWEB)

Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)

1999-09-01

493

Application of 10 GeV electron driven x-ray laser in gamma-ray laser research  

Energy Technology Data Exchange (ETDEWEB)

The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize [gamma]-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.

1992-01-01

494

Application of 10 GeV electron driven x-ray laser in gamma-ray laser research  

Energy Technology Data Exchange (ETDEWEB)

The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize {gamma}-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.

1992-12-01

495

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

496

THE EVOLUTION OF THE STAR FORMATION RATE OF GALAXIES AT 0.0 #<=# z #<=# 1.2  

International Nuclear Information System (INIS)

We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-ray emission. Optical emission line diagnostics are considered for ...

2010-08-01

497

Modification of surface texture by grinding and polishing lead zirconate titanate ceramics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that grinding and polishing affected the orientation of 90[degrees] domains at the surface of lead zirconate titanate (PZT) ceramics. This was quantified by using changes in the intensity ratio of the (002) and (200) X-ray reflections. Grinding unpoled PZT with 600-grit SiC paper gave X-ray intensity ratios similar to those of poled material. This implies that 90[degrees] domain realignments had occurred in the near surface region probed by the X-rays. Grinding poled samples with 600-grit SiC further increased the X-ray intensity ratio beyond that caused by poling, indicating that additional surface reorientation of 90[degrees] domains had occurred. The effects of diamond polishing depended on the size of the diamond particles. The use of 6-[mu]m diamond had no effect on the (002)/(200) intensity ratio of either poled or unpoled samples, while polishing with 15- or 45-[mu]m diamond ...

1992-08-01

498

An X-ray source population study of the Andromeda galaxy M 31  

CERN Document Server

XMM-Newton EPIC observations reveal the population of X-ray sources of the bright Local Group spiral galaxy M 31, a low-star-formation-rate galaxy like the Milky Way, down to a 0.2-4.5 keV luminosity of 4.4E34 erg/s. With the help of X-ray hardness ratios and optical and radio information different source classes can be distinguished. The survey detected 856 sources in an area of 1.24 square degrees. Sources within M 31 are 44 supernova remnants (SNR) and candidates, 18 super-soft sources (SSS), 16 X-ray binaries (XRBs) and candidates, as well as 37 globular cluster sources (GlC) and candidates, i.e. most likely low mass XRBs within the GlC. 567 hard sources may either be XRBs or Crab-like SNRs in M 31 or background AGN. 22 sources are new SNR candidates in M 31 based on X-ray selection criteria. Time variability information can be used to improve the source classification. Two GlC sources show type I ...

2005-01-01