WorldWideScience
1

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

2

Interpretation of EXAFS data from laser shock compressed plasmas  

Energy Technology Data Exchange (ETDEWEB)

Measurements on laser shock compressed aluminium using the EXAFS (Extended X-ray Absorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).

1989-01-01

3

Annealing, lattice disorder and non-Fermi liquid behavior in UCu4Pd  

Energy Technology Data Exchange (ETDEWEB)

The magnetic and electronic properties of non-Fermi liquid UCu{sub 4Pd} depend on annealing conditions. Local structural changes due to this annealing are reported from UL{sub III}- and Pd K-edge x-ray absorption fine-structure measurements. In particular, annealing decreases the fraction of Pd atoms on nominally Cu 16e sites and the U-Cu pair-distance distribution width. This study provides quantitative information on the amount of disorder in UCu{sub 4Pd} and allows an assessment of its possible importance to the observed non-Fermi liquid behavior.

2002-07-30

4

Element selective X-ray magnetic circular and linear dichroisms in ferrimagnetic yttrium iron garnet films  

Energy Technology Data Exchange (ETDEWEB)

X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG ...

2009-12-15

5

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The ...

2001-06-01

6

Anisotropy in Magnetic Properties and Electronic Structure of Single Crystal LiFePO4  

Energy Technology Data Exchange (ETDEWEB)

We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different ...

2008-01-01

7

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

8

Local structure of Ca dopant in BaTiO_3 by Ca K-edge X-ray absorption near-edge structure and first-principles calculations  

International Nuclear Information System (INIS)

The local environment of Ca dopants in barium titanate, BaTiO_3, is investigated by Ca K-edge X-ray absorption near-edge structure (XANES) spectroscopy. In conjunction with experiments, first-principles calculations by two methods are systematically made. The projector-augmented wave (PAW) method is used to optimize the local structure and obtain the formation energy. The augmented plane wave plus local orbitals method is adopted to obtain theoretical XANES spectra. A comparison between experimental and theoretical XANES spectra shows that Ca dopants are located at the Ba"2"+ sites forming Ca"2"+. Formation energy calculations of Ca doped BaTiO_3 by the PAW method also give the same results. The Ca atom in BaTiO_3 is off-centering in comparison with the Ba site in BaTiO_3. The off-centering of Ca atom is newly revealed by the combination of XANES spectroscopy and first-principles DFT calculations.

2010-06-01

9

Element-selective thermal x-ray magnetic circular dichroism study through the magnetic compensation temperature of Ho{sub 6}Fe{sub 23}  

Science.gov (United States)

We present an x-ray magnetic circular dichroism (XMCD) study performed on both Ho{sub 6}Fe{sub 23} and Y{sub 6}Fe{sub 23} compounds as a function of the temperature. The combined analysis of both Fe K-edge and Ho L{sub 2,3}-edge XMCD spectra recorded through the magnetic compensation transition allows us to disentangle the thermal dependence of both Fe and Ho magnetic moments in Ho{sub 6}Fe{sub 23}. In addition, contributions from Ho ions to the Fe K-edge XMCD signals and, conversely, from Fe ions to the Ho L{sub 2,3}-edge XMCD spectra have been clearly identified. These extra contributions, arising from the strong Fe(3d)-Ho(5d) hybridization, have been isolated from the spectra and correlated with the magnetic state of both Ho and Fe ions surrounding the absorbing site. The influence of these contributions to the values of the orbital and spin moments derived by using sum rule analysis is also shown.

2005-09-01

10

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

11

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

12

Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs  

Energy Technology Data Exchange (ETDEWEB)

The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS ...

1999-02-23

13

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as ...

2001-09-23

14

Synthesis and crystal structure of a new open-framework iron phosphate (NH4)4Fe3(OH)2F2[H3(PO4)4]: Novel linear trimer of corner-sharing Fe(III) octahedra  

International Nuclear Information System (INIS)

A new iron phosphate (NH4)4Fe3(OH)2F2[H3(PO4)4] has been synthesized hydrothermally at HF concentrations from 0.5 to 1.2 mL. Single-crystal X-ray diffraction analysis reveals its three-dimensional open-framework structure (monoclinic, space group P21/n (No. 14), a=6.2614(13) A, b=9.844(2) A, c=14.271(3) A, ?=92.11(1)o, V=879.0(3) A3). This structure is built from isolated linear trimers of corner-sharing Fe(III) octahedra, which are linked by (PO4) groups to form ten-membered-ring channels along [1 0 0]. This isolated, linear trimer of corner-sharing Fe(III) octahedra, [(FeO4)3(OH)2F2], is new and adds to the diverse linkages of Fe polyhedra as secondary building units in iron phosphates. The trivalent iron at octahedral sites for the title compound has been confirmed by synchrotron Fe K-edge XANES spectra and magnetic measurements. Magnetic measurements also show that this compound exhibit a strong ...

2010-12-01

15

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

16

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

17

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, ...

1988-01-01

18

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

19

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

20

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

21

Near-edge structures from first principles all-electron Bethe-Salpeter equation calculations  

International Nuclear Information System (INIS)

We obtain x-ray absorption near-edge structures (XANES) by solving the equation of motion for the two-particle Green's function for the electron-hole pair, the Bethe-Salpeter equation (BSE), within the all-electron full-potential linearized augmented plane wave method (FPLAPW). The excited states are calculated for the Li K-edge in the insulating solids LiF, Li_2O and Li_2S, and absorption spectra are compared with independent particle results using the random phase approximation (RPA), as well as supercell calculations using the core-hole approximation within density functional theory (DFT). The binding energies of strongly bound excitations are determined in the materials, and core-exciton wavefunctions are demonstrated for LiF.

2009-03-11

22

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

23

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

24

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

25

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

26

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled ...

2009-02-11

27

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are ...

28

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

29

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

30

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

31

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

32

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

33

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

34

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence ...

1989-11-01

35

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence ...

1989-11-01

36

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : ...

2003-11-01

37

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films ...

38

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

39

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

40

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

41

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

42

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

43

X-ray and vibrational spectroscopy of manganese complexes relevant to the oxygen-evolving complex of photosynthesis  

Energy Technology Data Exchange (ETDEWEB)

Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV ...

2001-05-16

44

X-ray absorption spectroscopy of bacterial sulfur globules  

Energy Technology Data Exchange (ETDEWEB)

Sulfur K-edge X-ray absorption spectroscopy is a powerful in situ probe of sulfur biochemistry in intact cells and tissues. Under favorable circumstances the technique can provide quantitative information on the chemical identify of the sulfur species that are present in a sample. Prange et al. have recently reported an X-ray absorption spectroscopic study of bacterial sulfur storage globules. Unfortunately there are substantial problems with the experimental technique employed that, they contend, lead to completely erroneous conclusions. In the more recent of their two papers Prange et al. employed a curve-fitting method similar to that used by us (for more than 10 years). In essence, the method employs simply fitting a linear combination of the spectra of standard compounds to that of the unknown, in this case cultures of bacterial cells. This type of analysis can provide quantitative estimates of the individual sulfur ...

2002-08-01

45

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

46

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

47

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

48

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

49

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

50

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

51

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

52

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

53

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

54

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

55

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

56

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

57

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

58

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

59

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

60

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

61

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

62

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

63

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

64

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

65

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

66

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

67

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

68

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

69

New materials synthesis: characterization of some metal-doped antimony oxides  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the chemistry of altermetal dopants in antimony oxide, the detailed structural characterization of two ..beta..-Sb/sub 2/O/sub 4/ compounds is reported, Mo-doped ..beta..-Sb/sub 2/O/sub 4/ (1.5 metal%) and V-doped ..beta..-Sb/sub 2/O/sub 4/ (5 metal%). The methods used to characterize these materials are X-ray and neutron diffraction, scanning electron microscopy, Mo K-edge extended X-ray absorption fine structure spectroscopy, and elemental analysis. The atomic position of each of these dopants in Sb/sub 2/O/sub 4/ is radically different as is the overall effect on the host structure. Molybdenum does not substitute for Sb atoms, rather the Mo atoms are found in channels of electron density formed by Sb/sup 3 +/ lone pairs. The two nearest Sb/sup 3 +/ are absent and the oxygen stoichiometry is preserved. The formula is Sb/sub 1.97/Mo/sub 0.015/O/sub 4/. Vanadium incorporates substitutionally for the ...

1986-10-01

70

Crosscheck of different techniques for two dimensional power spectral density measurements of x-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering ...

2005-07-12

71

Cross-check of different techniques for two-dimensional powerspectral density measurements of X-ray optics  

Energy Technology Data Exchange (ETDEWEB)

The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering ...

2005-04-17

72

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell ...

73

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics ...

2003-09-15

74

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the ...

76

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and ...

2009-08-11

77

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

78

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background ...

2004-01-01

79

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

Energy Technology Data Exchange (ETDEWEB)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray ...

1983-09-01

80

Direct chemical information from special radiotracers as well as from outer X-ray excitation  

International Nuclear Information System (INIS)

Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ...

1982-10-01

81

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The ...

2010-06-02

82

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by ...

1987-05-13

83

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in ...

1986-01-01

84

X-ray magnetic form factor of UTe  

Energy Technology Data Exchange (ETDEWEB)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

1995-07-01

85

X-ray magnetic form factor of UTe  

International Nuclear Information System (INIS)

A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).

86

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

87

Studies of L x-rays from 64 MeV iodine projectiles in collision with gas targets  

International Nuclear Information System (INIS)

We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)

1997-11-17

88

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ...

1987-01-01

89

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared ...

1987-01-01

90

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

91

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... The Payload combines some of the most sensitive particle sensors .... provide state-of-the-art measurements of incoming x-ray, ultraviolet, .... It will be launched into a low-Earth orbit on a Delta 7320 rocket in September 2004. ...

92

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

93

Temperature Dependence of Structure, Bending Rigidity, and Bilayer Interactions of Dioleoylphosphatidylcholine Bilayers  

UK PubMed Central (United Kingdom)

X-ray diffuse scattering was measured from oriented stacks and unilamellar vesicles of dioleoylphosphatidylcholine lipid bilayers to obtain the temperature dependence of the structure and of the material...Full Text Available

2008-01-01

94

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

95

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

96

Investigation of anomalous CXR response of filled cables  

Energy Technology Data Exchange (ETDEWEB)

An anomaly in the continuous X-ray (CXR) response of filled cables is described. A systematic investigation of this anomaly is pursued with a single cable type and a model explaining the anomaly is presented. The effect of the anomaly on the accuracy of CXR measurement of SGEMP response is discussed.

1982-12-01

97

Structural, Vibrational and Mechanical Studies of Hydroxyapatite produced by wet-chemical methods  

CERN Document Server

Hydroxyapatite samples were produced by two different wet-chemical methods, and characterized by x-ray diffraction, infrared and compression strength measurements. The x-ray diffraction measurements were simulated using the Rietveld method, and structural data as lattice parameters and average crystallite size were obtained. The infrared spectra showed the presence of CO$_3^{2-}$ ions in all samples, indicating a contamination by these ions. By mixing samples produced by both methods, a bioceramic was obtained and, after sintering, samples with very high compression strengths (26--30 MPa) were obtained.

2004-01-01

98

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

99

Measurement of AlP/GaP (001) heterojunction band offsets by x-ray photoemission spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoemission spectroscopy has been used to measure the valence band offset {Delta}E{sub v} for the AlP/GaP (001) heterojunction interface. The heterojunction samples were prepared by molecular-beam epitaxy. A value of {triangle}E{sub v}=0.43 eV is obtained (staggered band alignment, with AlP valence band below that of GaP). 24 refs., 8 figs., 1 tab.

1993-07-01

100

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

101

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

102

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

103

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

104

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production ...

1981-10-01

105

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

106

Influence of alloying effect on X-ray fluorescence parameters of Co and Cu in CoCuAg alloy films  

British Library Electronic Table of Contents (United Kingdom)

In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.

2009-01-01

107

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than ...

2007-08-21

108

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing ...

2007-08-21

109

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

110

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

111

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

112

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium ...

1986-01-01

113

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from Kbeta-to-Kalpha X-ray intensity ratio studies.  

Science.gov (United States)

Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other ...

2010-01-28

114

Valence-electron configuration of Ti and Ni in TixNi1-x alloys from K?-to-K? X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the ...

2010-06-01

115

The Orbit of the Eclipsing X-ray Pulsar EXO 1722-363  

CERN Document Server

With recent and archival Rossi X-Ray Timing Explorer (RXTE) X-ray measurements of the heavily obscured X-ray pulsar EXO 1722-363 (IGR J17252-3616), we carried out a pulse timing analysis to determine the orbital solution for the first time. The binary system is characterized by a_x sin(i) = 101 +/- 3 lt-s and P_orb = 9.7403 +/- 0.0004 days (90% confidence), with the precision of the orbital period being obtained by connecting datasets separated by more than 7 years (272 orbital cycles). The orbit is consistent with circular, and e 61 degrees at the 99% confidence level, the radius of the primary is between 21 R_sun and 37 R_sun, and its mass is less than about 22 M_sun. The acceptable range of radius and mass shows that the primary is probably a supergiant of spectral type B0I-B5I. Photometric measurements of its likely counterpart are consistent with the spectral type and ...

2006-01-01

116

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available ...

2008-05-22

117

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)

2008-10-15

118

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

119

X-ray diffraction evaluation of the structural perfection of cadmium telluride single crystals  

Science.gov (United States)

A high degree of structural perfection is an essential requirement for CdTe crystals used as substrates for the epitaxial growth of CdHgTe alloys. Here, a method for the evaluation of the structural perfection of CdTe crystals is proposed which is based on X-ray diffraction measurements using both two-crystal and three-crystal diffractometers (differential version). The method makes it possible to obtain more information on structural perfection both at the crystal surface and within the crystal body.

1988-08-01

120

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

121

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

122

The relative X-ray intensity Ksub(#alpha#)/Ksub(#beta#) of 3d elements by photoionization and electron capture  

International Nuclear Information System (INIS)

The measurement of K(alpha)/K(beta) X-ray intensity ratio indicates the excitation process and the chemical state of the atom examined. Theoretical considerations on the origin of this property are presented. The difference of these ratios following photoionization and electron capture are calculated by a computer code generating transition matrix elements. The theoretical assumptions involved in the codes are tested by comparing the experimental and calculated data concerning 3d transition element atoms. (D.Gy.).

1981-03-19

123

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

124

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

125

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

126

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

127

K_#beta#/K_#alpha# X-ray intensity ratio following K-electron capture and radioisotope excitation  

International Nuclear Information System (INIS)

The K_#beta#/K_#alpha# X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49<=Z<=82 following electron capture decay and photon excitation using "2"4"1Am and "5"7Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K_#beta#/K_#alpha# values on the mode of excitation in the case of Mn and Fe is attribuited to the chemical effects, while no such dependence is found for the high-Z elements.

1987-01-01

128

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

129

Core localized toroidal Alfven eigenmodes destabilized by energetic ions in the CHS heliotron/torsatron  

Energy Technology Data Exchange (ETDEWEB)

Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)

1999-09-01

130

Structure of molten alkali halides  

Energy Technology Data Exchange (ETDEWEB)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-06-01

131

Structure of molten alkali halides  

International Nuclear Information System (INIS)

The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...

1982-01-01

132

Phase, residual stress, and texture in triode-sputtered tantalum coatings on steel. Final report  

Energy Technology Data Exchange (ETDEWEB)

This work analyzes the unoptimized prototype triode-sputtered, 150 microns thick tantalum coatings deposited with a 2.5 microns niobium underlayer on the bore of a large-diameter A723 steel cylinder. The coating was deposited for wear and erosion protection by Pacific Northwest National Laboratory. The phase determination was based on X ray diffraction analysis, wavelength dispersive X ray fluorescence analysis, energy dispersive X ray analysis, and hardness and electrical resistivity measurements. Both X ray diffraction and radius-of- curvature methods were used to determine residual stresses. A locally developed high-resolution pole figure technique was used to perform texture analysis. The post-firing, debonded coating showed alpha-tantalum, preferred 110 orientation, high surface stresses, ...

1998-07-01

133

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

134

Ion-induced M X-ray emission from heavy lanthanides  

Energy Technology Data Exchange (ETDEWEB)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.

1987-12-01

135

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the ...

2003-05-15

136

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

137

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

138

X-ray ablation measurements and modeling for ICF applications  

Energy Technology Data Exchange (ETDEWEB)

X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and ...

1996-09-01

139

A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy  

International Nuclear Information System (INIS)

Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).

1979-01-01

140

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray ...

2008-12-15

141

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin ...

2008-12-01

142

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a ...

2004-01-01

143

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

144

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

145

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

146

Mapping Strain in Nanocrystalline Nitinol: an X-ray Diffraction Method (SULI paper)  

Energy Technology Data Exchange (ETDEWEB)

Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, ...

2006-01-04

147

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

148

Strain and Texture in Al-Interconnect Wires Measured by X-Ray Microbeam Diffraction  

Energy Technology Data Exchange (ETDEWEB)

The local strain and texture in Al interconnect wires have been investigated using white and monochromatic x-ray microbeams on the MHATTCAT undulator beam line at the Advanced Photon Source. Intergrain and intragrain orientations were obtained with ~0.01 degree sensitivity using white beam measurements on wide Al pads (~100 Mu-m) and thin (2 Mu-m) Al wires. Orientation changes of up to 1 degree were found within individual grains of the (111) textured Al interconnects. Deviatoric strain measurements indicate small intragranular strain variations, but intergranular strain variations were found to be quite large.

1999-04-05

149

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

150

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

151

X-Ray Fluorescence in Research on the Cultural Heritage  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the ...

2001-09-15

152

X-Ray Fluorescence in Research on the Cultural Heritage  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the ...

2001-09-01

153

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. ...

1995-03-11

154

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. ...

1995-03-01

159

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

160

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

161

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

162

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

163

Optimization of soft magnetic properties in Fe-B and Fe-B-Si amorphous alloys obtained by melt spinning method  

International Nuclear Information System (INIS)

In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)

2001-09-23

164

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

165

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An ...

1988-08-15

166

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more ...

2007-07-01

167

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

168

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

169

A New Measurement of Kaonic Hydrogen X rays  

CERN Document Server

The $\\bar{K}N$ system at threshold is a sensitive testing ground for low energy QCD, especially for the explicit chiral symmetry breaking. Therefore, we have measured the $K$-series x rays of kaonic hydrogen atoms at the DA$\\Phi$NE electron-positron collider of Laboratori Nazionali di Frascati, and have determined the most precise values of the strong-interaction energy-level shift and width of the $1s$ atomic state. As x-ray detectors, we used large-area silicon drift detectors having excellent energy and timing resolution, which were developed especially for the SIDDHARTA experiment. The shift and width were determined to be $\\epsilon_{1s} = -283 \\pm 36 \\pm 6 {(syst)}$ eV and $\\Gamma_{1s} = 541 \\pm 89 {(stat)} \\pm 22 {(syst)}$ eV, respectively. The new values will provide vital constraints on the theoretical description of the low-energy $\\bar{K}N$ interaction.

2011-01-01

170

X-ray photoelectron spectroscopy and x-ray excited Auger spectroscopy studies of manganese thiophosphate intercalated with sodium ions  

Science.gov (United States)

Polycrystalline powders of Na{sub 2x}Mn{sub 1-x}PS{sub 3} have been synthesized from layered MnPS{sub 3} material by successive ion-exchange intercalation of potassium and sodium ions. Their x-ray photoelectron spectroscopy (XPS) and x-ray excited Auger spectroscopy spectra have been measured at room temperature using Mg K{alpha} (1253.6 eV) x-ray source. In particular, the Mn, P, and S 2p and Na 1s and 2p core-level regions and the Na Auger KL{sub 23}L{sub 23} transition have been investigated. All the analyzed XPS core-level spectra display a single-peak structure, suggesting the absence of nonequivalent atoms of Na, Mn, P, and S. The manganese XPS spectrum shows, as observed in MnPS{sub 3} and in its cesium and potassium intercalation compounds, typical shake-up satellites, suggesting that the Mn-S bond is yet mainly ionic in nature. The comparison with the XPS spectra relative to MnPS{sub 3} and its ...

2008-12-15

171

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

172

Upgrade of X-ray Magnetic Diffraction Experimental System and Its Application to Ferromagnetic Material  

International Nuclear Information System (INIS)

We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the magnetization of YTiO3 along ...

2007-01-19

173

The peak to background method in quantitative ion microprobe analysis of thick biological specimens  

Energy Technology Data Exchange (ETDEWEB)

The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate ...

1991-05-01

174

Synthesis, spectral and X-ray structural studies of a NO donor Schiff base ligand and its Ni(II) complexes  

British Library Electronic Table of Contents (United Kingdom)

The Schiff base ligand, 4-isopropylbenzaldehyde[N-(3-oxo-3,4-dihydro-2-quinoxalinyl)hydrazone] (Ipbh), the 1:1 condensation product of 4-isopropylbenzaldehyde and 2-hydroxy-3-hydrazinoquinoxiline, has been synthesized and characterized by X-ray crystallography. A series of complexes of Ipbh with Nickel(II), viz., [Ni(Ipbh)2]Cl2 (1), [Ni(Ipbh)2]Br2 (2), [Ni(Ipbh)2]I2 (3), [Ni(Ipbh)2(CH3OH)2](NO3)2(CH3OH)2 (4) and [Ni(Ipbh)2ClO4]ClO4 (5) have been synthesized. All the complexes were characterized by elemental analysis, molar conductivity, CHN analysis, spectroscopic studies, magnetic susceptibility measurements and TG/DTA methods. The solid-state structure of the complex 4 was established by single crystal X-ray crystallography. In all the complexes, Ipbh acts as a bidentate NO chelating age...

2011-01-01

175

Previous heat treatment inducing different plasma nitriding behaviors in martensitic stainless steels  

International Nuclear Information System (INIS)

In this work we report a study of the induced changes in structure and corrosion behavior of martensitic stainless steels nitrided by plasma immersion ion implantation (PI"3) at different previous heat treatments. The samples were characterized by x-ray diffraction and glancing angle x-ray diffraction, scanning electron microscopy, energy dispersive x-ray spectroscopy, and potentiodynamic measurements. Depending on the proportion of retained austenite in the unimplanted material, different phase transformations are obtained at lower and intermediate temperatures of nitrogen implantation. At higher temperatures, the great mobility of the chromium yields CrN segregations like spots in random distribution, and the #alpha#"'-martensite is degraded to#alpha#-Fe (ferrite). The nitrided layer thickness follows a fairly linear relationship with the temperature and a parabolic law with the process time. The ...

2006-09-01

176

How epitaxial are Pd/sub 2/Si-Si interfaces  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si layers produced by evaporation or sputtering onto silicon substrates were examined by high resolution electron microscopy, microdiffraction, X-ray, energy loss and Auger spectroscopy. The Si-Pd/sub 2/Si interfaces produced by evaporation were in all cases rougher and more polycrystalline than those produced by sputtering. X-ray microanalysis showed the predictable variation in palladium distribution across the interface but quantification did not produce the expected palladium-to-silicon ratios, primarily because of probe broadening and X-ray-induced fluorescence. Energy loss spectra showed plasmon energy shifts and changes in Si L edge shape due to bond formation with palladium. Auger data provided evidence for a small amount of oxygen at the Si-Pd/sub 2/Si interface. Electrical measurements of the ideality factor for Schottky barriers made from the materials produced higher values for the ...

1983-06-17

177

Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques  

International Nuclear Information System (INIS)

Glasses in the system (1 - x) [29Na2O- 4Al2O3- 67B2O3]- xZnO (0 ? x ? 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N4 values (fraction of tetrahedral coordinated boron atoms), and substitution of longer bond lengths of ...

2009-05-05

178

Direct observation of radial distribution change during tensile deformation of metallic glass by high energy X-ray diffraction method  

International Nuclear Information System (INIS)

The purpose of this research is to investigate the micro-mechanism of deformation behavior of metallic glasses. We report the results of direct observations of short-range and medium-range structural change during tensile deformation of metallic glasses by high energy X-ray diffraction method. Cu50Zr50 and Ni30Zr70 metallic glass samples in the ribbon shape (1.5 mm width and 25 ?m) were made by using rapid quenching method. Tensile deformation added to the sample was made by using special equipment adopted for measuring the high energy X-ray diffraction. The peaks in pair distribution function g(r) for Cu50Zr50 and N30iZr70 metallic glasses move zigzag into front and into rear during tensile deformation. These results of direct observation on atomic distribution change for Cu50Zr50 and Ni30Zr70 metallic glass ribbons during tensile deformation suggest that the micro-relaxations occur.

2009-08-26

179

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

180

Zeolite-supported catalysts. Report for August 1986-November 1987  

Energy Technology Data Exchange (ETDEWEB)

The present paper is a comparative study of the cerium-containing nickel catalysts supported on x- and y-zeolites. In general, the addition of cerium ions caused an increase in the catalytic activity for CO hydrogenation and shifted the product selectivity to high molecular weight hydrocarbons. The degree of the effect of cerium additive depends on the ratio of cerium to nickel contents, the reduction temperature, and the nature of the supporting materials. Catalyst characterization, including volumetric hydrogen chemisorption, temperature programmed reduction/desorption, x-ray diffraction, surface area measurements, in-situ infrared spectroscopy and x-ray photoelectron spectroscopy, was performed in order to interpret the phenomena due to the effects of cerium additives and the support effect on Ni/zeolite catalysts.

1988-01-01

181

X-ray fluorescence in research on Czech cultural monuments  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

182

X-ray fluorescence in research on Czech cultural monuments  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

183

X-ray Microdiffraction and Strain Gradient Crystal Plasticity Studies of Geometrically Necessary Dislocations Near a Ni Bicrystal Grain Boundary  

Energy Technology Data Exchange (ETDEWEB)

We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.

2009-01-01

184

The energy dependence of L_#alpha#/L_l X-ray intensity ratio produced by heavy-ion bombardment  

International Nuclear Information System (INIS)

The energy dependence of the Yb and Au L_#alpha#/L_l X-ray intensity ratio, produced by 0.5 - 3.0 MeV/u Li, Be, C, N, F, and Si ion bombardment (Malhi and Gray, Phys. Rev. A 44, 7199, (1991)), measured at 90"0 relative to the beam axis, has been explained. While for light ion impact the behaviour of the alignment parameter as a function of impact velocity is dominant, for the impact of heavier ions the multiple ionization effects become important. Using Larkins' prescription in the last case, calculations have been performed, which agree well with the data over the whole energy range investigated. (Author).

1993-01-01

185

Spatial distribution of arsenic and heavy metals in willow roots from a contaminated floodplain soil measured by X-ray fluorescence spectroscopy  

British Library Electronic Table of Contents (United Kingdom)

Under changing redox conditions some plants create plaques at their root surface, which may affect the mobility and uptake of As and heavy metals but it is unknown to what extent this also holds true for willows in contaminated floodplain soils. Therefore, willow roots were sampled from a phytoremediation trial in the contaminated floodplain of the river Elbe (Germany), cryofixed, freeze-dried, and cross sections were mapped for the distribution of As, Ca, Cu, Fe, K, Mn, Ni, S and Zn by synchrotron based X-ray fluorescence spectroscopy. The elements Ca, Cu, Ni, S and Zn were concentrated in the aerenchymatic tissue, and not associated with Fe and Mn. Mixed Fe-Mn plaques covered the surface of the willow roots and As was accumulated in these plaques. The observed association pattern between...

2011-01-01

186

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the ...

1998-06-18

187

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

188

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

189

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

190

Optical and X-ray characterization of ferroelectric strontium-bismuth-tantalate (SBT) thin films  

International Nuclear Information System (INIS)

Metal-organic chemical vapor deposition (MOCVD) made layers of strontium-bismuth-tantalate (SBT) were characterized by spectroscopic ellipsometry (SE) using the Adachi model [S. Adachi, Phys. Rev. B 35 (1987) 7454-7463]. The evaluated optical parameters were correlated with the physical and chemical behavior examined by X-ray diffraction (XRD). As a result, it was possible to fit the measured spectra with the Adachi model in a wide range covering the region of the band gap. The Adachi model provides electronic layer parameters like the transition energy E 0 and broadening ?. Our investigations established a correlation between XRD-determined average grain size and the electronic layer parameters.

2006-10-31

191

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

192

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

193

Microstructure analysis of nanocrystalline powders by X-ray diffraction  

International Nuclear Information System (INIS)

The use of X-ray diffraction line profile analysis for the study of nanocrystalline powders is described. The fundamentals of the theory are presented in terms of crystallite/domain size, size distribution, lattice distortion, dislocations density and stacking faults. Line profile parameters and the methods of pattern fitting introduced to overcome the diffraction-line overlap problem are discussed. The approaches based of the integral breadth of the measured line profiles and the Fourier method are discussed. In addition, simplified approaches are also commented. Representative examples are selected to illustrate various cases of microstructure, such as nanomaterials with strain-free spherical nano crystallites, strain-free crystallites with anisotropic crystallite shape, anisotropic crystallites with microstrains and spherical crystallites with dislocation densities and crystallite size distributions. (author)

2001-09-23

194

Lowering the activation temperature of TiZrV non-evaporable getter films [for LHC  

CERN Document Server

In order to reduce the activation temperature of the TiZrV alloy, thin films of various compositions were produced by three-cathode magnetron sputtering on stainless-steel substrates. For the characterisation of the activation behaviour the surface chemical composition has been monitored by Auger electron spectroscopy during specific in situ thermal cycles. The volume elemental composition of the film has been measured by energy dispersive X-ray spectroscopy and the morphology (crystal structure and size of the crystallites) has been investigated by X-ray diffraction. The criteria indicating the sample quality and its dependence on film structure and chemical composition are presented and discussed. (13 refs).

2001-01-01

195

Load transfer in bovine plexiform bone determined by synchrotron x-ray diffraction.  

Energy Technology Data Exchange (ETDEWEB)

High-energy synchrotron x-ray diffraction (XRD) has been used to quantify load transfer in bovine plexiform bone. By using both wide-angle and small-angle XRD, strains in the mineral as well as the collagen phase of bone were measured as a function of applied compressive stress. We suggest that a greater proportion of the load is borne by the more mineralized woven bone than the lamellar bone as the applied stress increases. With a further increase in stress, load is shed back to the lamellar regions until macroscopic failure occurs. The reported data fit well with reported mechanisms of microdamage accumulation in bovine plexiform bone.

2008-02-01

196

K/sub. beta. //K/sub. cap alpha. / X-ray intensity ratio following K-electron capture and radioisotope excitation  

Energy Technology Data Exchange (ETDEWEB)

The K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios are measured for Mn and Fe and for six other elements with Z lying in the range 49 less than or equal to Z less than or equal to 82 following electron capture decay and photon excitation using /sup 241/Am and /sup 57/Co sources. High-resolution Si(Li) and HpGe detector systems were used in the experiments. The dependence of K/sub ..beta..//K/sub ..cap alpha../ values on the mode of excitation in the case of Mn and Fe is attributed to chemical effects, while no such dependence is found for the high-Z elements.

1987-01-01

197

K-shell x-ray production cross sections of selected elements from Ti to Y for 0.5- to 2.5-MeV alpha-particle bombardment  

International Nuclear Information System (INIS)

K-shell x-ray production cross sections and K#beta#/K#alpha# ratios have been measured for thin targets of Ti, V, Cr, Fe, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, and Y for 0.5- to 2.5-MeV alpha particles. The experimental values are compared to the nonrelativistic plane-wave Born approximation (PWBA), the binary-encounter approximation, and the PWBA with binding energy and Coulomb deflection corrections. The PWBA with corrections provides the best agreement with the experimental cross sections.

198

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

199

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

200

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

International Nuclear Information System (INIS)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)

2008-03-01

201

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

British Library Electronic Table of Contents (United Kingdom)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...

2008-01-01

202

Chemical state analysis of Si-base ceramics sliding materials by EPMA  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the present study is to develop a new method for chemical state analysis by means of EPMA(Electron probe microanalyser). The measured X-ray intensity of Si-K{beta} characteristic X-ray spectra were read-out by a 16 bit microcomputer with a RS-232C interface. And using the curve fitting method the quantitative analysis of chemical compositions in a ternary compound that constituted of the same element has been established. The present method was applied to analyse of the friction and wear properties of Si-base ceramics sliding materials. It was found that the wear debris contains both the compositions of the sliding materials and SiO{sub 2}, and the SiO{sub 2} contents in wear debris was changed with relative humidity. The results clearly showed that the proposed method is very useful for determing the compositions in the ternary compound. (author).

1994-03-01

203

Chemical state analysis of Si-base ceramics sliding materials by EPMA  

International Nuclear Information System (INIS)

The purpose of the present study is to develop a new method for chemical state analysis by means of EPMA(Electron probe microanalyser). The measured X-ray intensity of Si-K#beta# characteristic X-ray spectra were read-out by a 16 bit microcomputer with a RS-232C interface. And using the curve fitting method the quantitative analysis of chemical compositions in a ternary compound that constituted of the same element has been established. The present method was applied to analyse of the friction and wear properties of Si-base ceramics sliding materials. It was found that the wear debris contains both the compositions of the sliding materials and SiO_2, and the SiO_2 contents in wear debris was changed with relative humidity. The results clearly showed that the proposed method is very useful for determing the compositions in the ternary compound. (author).

204

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of ...

2007-07-25

205

Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays  

Energy Technology Data Exchange (ETDEWEB)

We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue ...

2005-10-11

206

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

207

Structural relaxation and crystallization in the Fe-Cr-Si-B and Fe-Cu-Cr-Si-B amorphous alloys  

International Nuclear Information System (INIS)

Structural relaxation, crystallization and optimisation processes in soft magnetic amorphous alloys based on iron are examined by applying different experimental techniques: X-ray diffraction analysis, high-resolution electron microscopy, measurements of magnetic and electric properties (permeability, after-effect resistivity). The presented results are discussed in terms of annealing out of microvoids, formation of nanocrystalline phase and changes of effective magnetostriction constant. (author)

2001-09-23

208

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

209

Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi  

International Nuclear Information System (INIS)

An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).

210

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

211

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

212

Energy dependence of Ksub(#beta#)/Ksub(#alpha#) intensity ratio of Si0_2 from proton induced ionisation  

International Nuclear Information System (INIS)

The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).

1980-04-01

213

Depth profile of uncompensated spins in an exchange bias system  

Energy Technology Data Exchange (ETDEWEB)

We have used the unique spatial sensitivity of polarized neutron and soft x-ray beams in reflection geometry to measure the depth dependence of magnetization across the interface between a ferromagnet and antiferromagnet. The new uncompensated magnetization near the interface responds to applied field, while the uncompensated spins in the antiferromagnetic bulk are pinned, thus providing a means to establish exchange bias.

2005-05-17

215

Valence-electron configuration of Ti and Ni in Ti{sub x}Ni{sub 1-x} alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti{sub x}Ni{sub 1-x} (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi {sup 109}Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K{beta}-to-K{alpha} X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one ...

2010-06-15

216

Study of the lattice parameter evolution of PWR irradiated MOX fuel by X-Ray diffraction; Etude de l'evolution du parametre cristallin des combustibles MOX irradies en rep par la methode de diffraction des rayons X  

Energy Technology Data Exchange (ETDEWEB)

Fuel irradiation leads to a swelling resulting from the formation of gaseous (Kr, Xe) or solid fission products which are found either in solution or as solid inclusions in the matrix. This phenomena has to be evaluated to be taken into account in fuel cladding Interaction. Fuel swelling was studied as a function of burn up by measuring the corresponding cell constant evolution by X-Ray diffraction. This study was realized on Mixed Oxide Fuels (MOX) irradiated in a Pressurized Water Reactor (PWR) at different burn-up for 3 initial Pu contents. Lattice parameter evolutions were followed as a function of burn-up for the irradiated fuel with and without an annealing thermal treatment. These experimental evolutions are compared to the theoretical evolutions calculated from the hard sphere model, using the fission product concentrations determined by the APPOLO computer code. Contribution of varying parameters influencing the unit cell value is ...

1995-07-01

217

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional ...

2008-05-22

218

M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium  

International Nuclear Information System (INIS)

M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross ...

219

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

220

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

221

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

222

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

223

Radioanalytical determination of chromium in welding fumes  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that ...

1985-01-01

224

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...

1976-05-21

225

Masses of Neutron Stars in High-Mass X-ray Binaries with Optical Astrometry  

CERN Document Server

Determining the type of matter that is inside a neutron star (NS) has been a long-standing goal of astrophysics. Despite this, most of the NS equations of state (EOS) that predict maximum masses in the range 1.4-2.8 solar masses are still viable. Most of the precise NS mass measurements that have been made to date show values close to 1.4 solar masses, but a reliable measurement of an over-massive NS would constrain the EOS possibilities. Here, we investigate how optical astrometry at the microarcsecond level can be used to map out the orbits of High-Mass X-ray Binaries (HMXBs), leading to tight constraints on NS masses. While previous studies by Unwin and co-workers and Tomsick and co-workers discuss the fact that the future Space Interferometry Mission should be capable of making such measurements, the current work describes detailed simulations for 6 HMXB systems, including predicted constraints on ...

2010-01-01

226

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

227

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

228

Microstructural analysis of a plasmanitrided tool steel by means of metallography and X-ray diffraction; Mikrostrukturelle und roentgenographische Analysen an einem plasmanitrierten Schnellarbeitsstahl  

Energy Technology Data Exchange (ETDEWEB)

Nitriding leads to improved tribological and corrosive properties of iron alloy components. In order to study the effect of plasma nitriding parameters on the structure of compound layer and diffusion zone, a systematic variation of process parameters, temperature and process gas atmosphere has been carried out. Metallographic inspection, X-ray diffraction and glow discharge optical spectroscopy analysis (GDOES) were used in this investigation. The results clarified that depending on the amount of nitrogen in the gas atmosphere nitrided layers with and without compound layer can be generated in the surface of M2 tool steel for temperatures from 350 C to 500 C. For plasma nitriding in 5 vol.% Nitrogen and 95 vol.% Hydrogen no compact compound layer was formed. The gas mixture of 76 vol.% Nitrogen resulted in compound layer formation for all temperatures from 350 C to 500 C. X-ray phase analysis indicated an almost 100% {epsilon}-(carbo)nitride ...

2001-09-01

229

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that the third factor varies from approximately 4.5% for "6"0Co #gamma#-rays to 0.5% for ...

230

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

Energy Technology Data Exchange (ETDEWEB)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-12-01

231

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

International Nuclear Information System (INIS)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-07-12

232

Features of local atomic structure of nanocrystalline disordered Fe-M (M=Ge, Sn, Al, Si) alloys: EXAFS-study  

International Nuclear Information System (INIS)

The EXAFS-study (Fe, Sn and Ge K-edges) of disordered by mechanical activation binary supersaturated nanocrystalline solid solutions Fe-Al, Fe-Ge, Fe-Sn and Fe-Si is presented. The EXAFS-spectra are processed by solving the inverse binary problem, using the EXAFS-spectrum of the Fe K-edge only or combining the EXAFS-spectra on two K-edges, Fe and Ge or Fe and Sn. The parameters of partial correlation functions indicate chemical short-range ordering, high local static distortions in the lattice, increasing with metalloid content. The macrostructure of other type is forming through an initial, 'local' stage within the bcc lattice.

2007-05-21

233

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

234

Reduced levels of MMP-2 and TIMP-1 in dyssegmental dysplasia.  

Science.gov (United States)

Matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) were measured in a mild case of dyssegmental dysplasia. X-ray pictures of a female baby born vaginally at 39 weeks of gestation showed short, bent, dumbbell-shaped long bones of the limbs and profound dyssegmental ossification in the spine, findings characteristic of dyssegmental dysplasia. When the levels of MMP-1, MMP-2, MMP-9, TIMP-1, and TIMP-2 were measured, the levels of MMP-2 and TIMP-1 were significantly reduced. This case might provide a clue to disclose the etiology of dyssegmental dysplasia. PMID:12568417

2003-02-01

235

Electron microscopy and X-ray diffraction study of AlN layers  

International Nuclear Information System (INIS)

AlN nanocrystalline layers and superstructures are used in the modern optoelectronic technology as reflecting mirrors in semiconductor layers. In the present work the properties of AlN films prepared by sputtering methods from an AlN target in reactive Ar + N plasma were investigated. The characterization was performed with HRTEM, SEM, glancing angle XRD and RBS methods. The present measurements confirmed the polycrystalline structure of AlN layers and enabled the evaluation of their grain size. The roughness and thickness of the layers were additionally determined by ellipsometric and profilometric measurements. (author)

2001-09-23

236

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

238

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

239

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

240

The End of Amnesia: A New Method for Measuring the Metallicity of Type Ia Supernova Progenitors Using Manganese Lines in Supernova Remnants  

CERN Document Server

We propose a new method to measure the metallicity of Type Ia supernova progenitors using Mn and Cr lines in the X-ray spectra of young supernova remnants. We show that the Mn to Cr mass ratio in Type Ia supernova ejecta is tightly correlated with the initial metallicity of the progenitor, as determined by the neutron excess of the white dwarf material before thermonuclear runaway. We use this correlation, together with the flux of the Cr and Mn Kalpha X-ray lines in the Tycho supernova remnant recently detected by Suzaku (Tamagawa et al. 2008) to derive a metallicity of log(Z) = -1.32 (+0.67,-0.33) for the progenitor of this supernova, which corresponds to log(Z/Zsun)= 0.60 (+0.31,-0.60) according to the latest determination of the solar metallicity by Asplund et al. (2005). The uncertainty in the measurement is large, but metallicities much smaller than the solar value can be confidently discarded. We ...

2008-01-01

241

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the ...

2008-07-14

242

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

243

Direct observation of ordered orbital of YTiO_3 by the X-ray magnetic diffraction technique  

International Nuclear Information System (INIS)

X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO_3 for the first time. The orbital-magnetic form factor #mu# _L(k) and the spin-magnetic form factor #mu# _S(k) were independently measured by utilizing the LS separation ability of the XMD. The #mu# _L(k) was measured for ten reciprocal-lattice points. No significant values of the #mu# _L(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The #mu# _S(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the #mu# _S(k) gave the spin density distribution m _S(r) in the real space. The obtained m _S(r) map shows the characteristic feature of the electron distribution of 3d electron in the t_2_g state of a Ti atom coordinated by O"2"- ions, in which the electrons are distributed away ...

2005-08-01

244

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after ...

2005-01-01

245

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating ...

2007-08-01

246

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the ...

1997-04-01

247

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...

2010-11-24

248

K and L x-ray production cross sections excited by 14.00--34.16 MeV #alpha#-particle beams  

International Nuclear Information System (INIS)

K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields ...

249

Phosphate/UO{sub 2} interaction during in vitro dissolution of inhalable particles in a medium simulating the phagolysosomal compartment  

Energy Technology Data Exchange (ETDEWEB)

Qualitative and quantitative methods have been developed to relate phosphate/UO{sub 2} interactions and U dissolution, in vitro, in a medium containing 0 or 10 mM phosphate concentrations at pH 5. This was performed by Energy Dispersive X ray Spectrometry (EDS) at 200 kV on entire particles and by fluorimetric measurement. The U dissolution rate was larger in a medium without phosphate than in a medium containing 10 mM phosphate. During the first day, the initial U dissolution involved 80.55% and 91.13% of the powder in media with and without phosphate respectively. From 5 to 15 d after beginning the assay, the dissolution half-times were longer than 92 d and 22 d for media with and without phosphate. EDS analyses have shown a constant P/U X ray intensity ratio for reference U{sub 2}O(PO{sub 4}){sub 2} for the same range of particle diameter. A gradual increase of this ratio was ...

1998-07-01

250

K{beta}-to-K{alpha} X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV {gamma}-rays from a 200 mCi {sup 241}Am point-source. The K{beta}-to-K{alpha} intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K{beta}-to-K{alpha} intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi{sub 2} and CuSi{sub 2}.

1999-06-01

251

K#beta#-to-K#alpha# X-ray intensity ratio studies on the changes of valence electronic structures of Ti, V, Cr, and Co in their disilicide compounds  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, V, Cr, and Co in pure metals and their disilicide compounds have been measured following excitation by 59.54 keV #gamma#-rays from a 200 mCi "2"4"1Am point-source. The K#beta#-to-K#alpha# intensity ratios of all these metals in the disilicide compounds are found to be less than the corresponding ratios for pure metals. Comparison of the measured K#beta#-to-K#alpha# intensity ratios for the disilicides and pure metals with the multiconfiguration Dirac-Fock calculations indicates increase of the 3d electron populations of Ti, V, Cr, and Co in the disilicides from their pure metal values suggesting the rearrangement of electrons between 3d and 4s states of the individual metal atom. This rearrangement is found to be opposite to that observed in our previously reported work on NiSi_2 and CuSi_2.

1999-06-01

252

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex D - Full-scale test of wind turbine blade, using sensors and NDT  

Energy Technology Data Exchange (ETDEWEB)

A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated ...

2002-05-01

253

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the ...

1990-01-01

254

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between ...

1990-05-01

255

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between ...

1990-05-01

256

Change in pore structure of coals by activation with KOH; KOH fukatsushita sekitan no saiko kozo  

Energy Technology Data Exchange (ETDEWEB)

Three typical Japanese coals of non-coking coal, coking coal and anthracite were heat-treated with KOH, and change in their pore structure was examined by absorption of N2, X-ray diffraction and TEM observation. In addition, the relation between a coal rank and pore structure was also studied by absorption experiment of N2. In experiment, the mixture of coal and KOH in a nickel holder was heat-treated in N2 gas flow at heating rate of 2{degree}C/min, and held at a fixed temperature for one hour. To clarify the pore structure, N2 absorption isotherms were measured at -196{degree}C under nearly 76cmHg using a commercially available full-automatic absorption measurement equipment. Based on the X-ray diffraction and TEM observation results on activated coals, the relation between the N2 absorption and pore structure was studied. The results are summarized as follows: (1) The yield and absorption ability of ...

1996-10-28

257

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of tissueequivalent ...

2010-10-01

258

Structural origin of optical bowing in semiconductor alloys p  

Energy Technology Data Exchange (ETDEWEB)

The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-ray absorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.

1983-08-22

259

Structural origin of optical bowing in semiconductor alloys p  

International Nuclear Information System (INIS)

The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-ray absorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.

260

Stresses and interfacial structure in Au-Ni and Ag-Cu metallic multilayers  

Energy Technology Data Exchange (ETDEWEB)

Metallic multilayers offer a fantastic playground to investigate elastic stresses in films of nanometer thickness. We will present and discuss a few examples from our recent work on Au-Ni and Ag-Cu systems where we combined plate bending measurements and electron or X-ray diffraction to investigate stress buildup and interfacial mixing. Comparing these two cases we discuss the results with respect to basic parameters like the misfits in lattice parameters and in elastic moduli, the mixing enthalpies and the surface energies.

2004-03-15

261

Radioprotective activity in some medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Water-soluble, ethanol-insoluble extracts prepared from several medicinal herbs of the Araliaceae and other families were tested for their radioprotective activity by either measuring 30 days survival rates (a commonly applied method) or counting the thrombocytes 14 days after irradiation (an improved method) in mice. The extracts were i.p. injected once within 4 min after the whole body X-ray irradiation. Of 12 materials examined, Aralia elata, Angelica acutiloba and Morus bombysis seemed to be good starting materials for preparing radioprotective substance(s) because of their relatively high specific activity and high yields of the extracts. (author).

1993-09-01

262

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

263

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

264

Nanocrystallization of the amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloys studied by the Moessbauer spectroscopy  

International Nuclear Information System (INIS)

Formation of the soft magnetic nanostructure in amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloy due to heat treatment is studied by the Moessbauer, differential scanning calorimetry, and X-ray diffraction techniques. Annealing at temperatures 520-580 "oC leads to the formation of extremely soft nanocrystalline alloy as revealed by the rf-Moessbauer measurements. The superparamagnetic behaviour was observed for the alloy annealed at 620-640 "oC. At higher annealing temperatures good soft magnetic properties deteriorate. (author)

2001-09-23

265

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

266

Measurement of stress in materials using chromium K/sub. beta. / radiation  

Energy Technology Data Exchange (ETDEWEB)

Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.

1983-01-01

267

Influence of the massicot Pb O in PLZT ceramics  

International Nuclear Information System (INIS)

(Pb_1_-_x La_x) (Zr_0_._6_5 Ti_0_._3_5) ceramics, with x = 0.09 (PLZT 9/65/35) were prepared using lead monoxide (Pb O) with different amount of litharge (tetragonal) and massicot (orthorhombic) phases. Results, based on x-ray diffraction patterns, remanent polarization and dielectric measurements, show that the Pb O polymorphic phase does not change the final structure of the PLZT but causes changes on the remanent polarization and dielectric permittivity temperature dependence. (author). 11 refs, 2 figs, 2 tabs.

1994-06-18

268

Influence of microalloying on the corrosion resistance of steel in saturated calcium hydroxide  

International Nuclear Information System (INIS)

The influence of microalloying vanadium or titanium on improving the corrosion resistance of mild steel in saturated calcium hydroxide solution was investigated. Potential-time, potentiodynamic polarization, and impedance measurement techniques were employed. The corrosion products have been examined by infrared and X-ray diffraction analysis and by scanning electron microscopy. It has been shown that the grain refining, due to microalloying, plays an important role in enhancing the corrosion resistance of steel. Scales of calcite and iron oxides on top of a protective oxide are formed on the investigated steels.

269

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

270

EXAFS Study of Semimetal-Semiconductor Transition of Bismuth Clusters  

International Nuclear Information System (INIS)

Extended X-ray absorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.

2007-02-02

271

Creation of an antiferromagnetic exchange spring  

Science.gov (United States)

We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.

2004-04-06

272

Atomic photoelectric effect near threshold edges  

Energy Technology Data Exchange (ETDEWEB)

Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub ..cap alpha..//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.

1985-07-01

273

Atomic photoelectric effect near threshold edges  

International Nuclear Information System (INIS)

Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub #alpha#//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.

1985-01-01

274

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

Energy Technology Data Exchange (ETDEWEB)

The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.

1983-05-01

275

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

International Nuclear Information System (INIS)

The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).

1983-01-01

276

Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence  

International Nuclear Information System (INIS)

The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in ...

2004-02-27

277

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...

280

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

286

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

287

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

288

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

290

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

291

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

295

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

296

[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].  

Science.gov (United States)

Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295

1986-01-01

297

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

298

X-ray and IR analysis of Cu-Si ferrite  

Science.gov (United States)

Polycrystalline soft ferrite, Cu1+xSixFe2?2xO4 (x=0.0, 0.05, 0.1, 0.15, 0.2 and 0.3) were prepared by standard ceramic technique. The X-ray analysis confirmed the single phase formation of the samples up to x=0.1 beside a second phase for x?0.15. The lattice parameter was found to decrease with composition(x), which is attributed to ionic size difference of cations involved. The bulk density measurements shows two different behavior for x0.15. The IR spectra of Cu Si ferrite system have been analyzed in the frequency range 200 1200 cm?1. It revealed two prominent bands ?1 and ?2 which are assigned to tetrahedral and octahedral metal complexes, respectively. The position of the highest frequency band is around 575 cm?1 while the lower frequency band is around 400 cm?1.

2006-08-01

299

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. ...

300

Void fraction estimation within rod bundles based on three-fluid model and comparison with X-ray CT void data  

Energy Technology Data Exchange (ETDEWEB)

An interfacial shear stress equation in the dispersed-annular two-phase flow regime has been developed, which is based on a three-fluid model consisting of a liquid film on a rod, vapor and entrained liquid associated with a vapor flow. It is an extension of J.G.M. Andersen's procedure that provides a two-fluid interfacial shear stress equation using the drift flux parameters C{sub 0} and V{sub gj}. This interfacial shear stress equation can take into account a phase and velocity distribution through an equivalence between the drift flux parameters and the interfacial shear stress. Using the three-fluid subchannel analysis code TEMPO with the three-fluid interfacial shear stress model the capability of a three-fluid calculation using the drift flux parameters C{sub 0} and V{sub gj} that reproduce a measured void fraction is demonstrated. A comparison was made with advanced X-ray computed tomography (CT) void fraction data within a 4x4 ...

1990-06-01

301

Tribological behavior of duplex coating improved by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

In the present paper the tribological behavior of the coatings are discussed. Duplex coatings were applied on cold working steel 100Cr6. Samples were plasma nitrided at different thickness of plasma surface layers. TiN was deposited with a classic BALZERS PVD equipment and subsequent ion implantation. Ion implantation was provided with N{sup 5+} ions. The other samples were produced with IBAD technology in DANFYSIK chamber. Wear resistance and exchanges of friction coefficient were measured with on-line test using special designed tribology equipment. Following the tests, the wear zone morphology and characteristics of surface layer structure as well as important properties were investigated by scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). Scratch adhesion testing was performed using commercially available equipment. Energy dispersive X-ray analysis (EDAX) of the wear-scars on pins provided ...

2004-07-01

302

Structural, electronic and magnetic properties of splat-quenched FeCsub(x) alloys (x<0.05)  

International Nuclear Information System (INIS)

The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity ...

2006-01-01

303

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a ...

1989-06-01

304

Processing and characterization of polyethylene/Brazilian clay nanocomposites  

Energy Technology Data Exchange (ETDEWEB)

Nanocomposites containing polyethylene (PE) and montmorillonite clay organically modified (OMMT) with quaternary ammonium salts were obtained via direct melt intercalation. A montmorillonite sample from the Brazilian state of Paraiba was treated with four different types of quaternary ammonium salts. After the treatment, the powder was characterized by X-ray diffraction and scanning electron microscopy. The dispersion and morphologies of OMMT within PE were investigated by X-ray diffraction and transmission electron microscopy. The results revealed the formation of intercalated montmorillonite layers in the PE matrix. The thermal stability and flammability of the PE/montmorillonite clay nanocomposites were measured by thermogravimetry and horizontal burning tests for HB classification, Underwrites Laboratories (UL 94), respectively. It was shown that the samples do not degrade at the processing temperature. By adding only 3 ...

2007-02-15

305

Photocatalytic self-cleaning properties of cellulosic fibers modified by nano-sized zinc oxide  

International Nuclear Information System (INIS)

Nano-sized zinc oxide was synthesized and deposited onto cellulosic fibers using the sol-gel process at ambient temperature. The prepared materials were characterized using several techniques including scanning electron microscopy, transmission electron microscopy, diffuse reflectance spectroscopy, X-ray diffraction and thermogravimetric analysis. X-ray diffraction studies of the ZnO-coated fiber indicate formation of the hexagonal crystal phase which was satisfactory crystallized on the fiber surface. The electron micrographs show formation of zinc oxide nanoparticles within 10-15 nm in size which have been homogeneously dispersed on the fiber surface. The prepared materials show significant photocatalytic self-cleaning activity, which was monitored by diffuse reflectance spectroscopy. The photoactivity was studied upon measuring the photodegradation of methylene blue and eosin yellowish under UV-Vis irradiation. The ...

2011-03-31

306

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

307

Nature of magnetic coupling between Mn ions in as-grown Ga1-xMnxAs studied by x-ray magnetic circular dichroism  

International Nuclear Information System (INIS)

The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous magnetic properties of many DMS's. (author)

2009-07-01

308

Nanostructured p-CuIn3Se5/n-CdS heterojunction engineered using simple wet chemical approach at room temperature for photovoltaic application  

British Library Electronic Table of Contents (United Kingdom)

Herein, we report engineering of nanostructured p-CuIn3Se5/n-CdS heterojunction thin film on a glass substrate, which is prepared at room temperature using simple wet chemical approach involving ion exchange reactions between CdS and Cu^+, In^3^+ and Se^2^- ions in alkaline medium. The uniform deposition of heterojunction thin films is achieved by optimizing the pH, temperature and molarity of the reactant bath. The as-deposited thin-films were annealed at 200^oC in air for 1h and further characterized for structural, optical and electrical properties using UV-Vis spectrophotometer, X-ray diffraction (XRD), scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy (XPS), Hall effect for type of conductivity, and I-V measurement to investigate the char...

2011-01-01

309

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

310

Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects  

CERN Document Server

Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...

2008-01-01

311

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

312

In-situ X-ray diffraction approach to surface film growth kinetics  

Science.gov (United States)

A knowledge of surface film growth kinetics can be quite useful in the production of materials for uses ranging from protective coatings to microelectronic devices. A technique for determining the kinetics of film growth is presented which should prove to be a valuable alternative to the array of spectroscopies (AES, RBS, etc.) currently favored for these measurements. Some of the virtues of this X-ray diffraction approach are its non-destructive nature, thickness resolution better than 50 {angstrom} and conventional equipment requirements. Results obtained for the growth of Pd{sub 2}Si films during thermal annealing of Pd coatings on Si, indicate parabolic growth over a temperature range of 160-222 C. The rate constant was found to be k{prime} = 7 {times} 10{sup {minus}4} exp ({minus}1.06 eV/kT) cm{sup 2}/sec, where (film thickness){sup 2} = k{prime} x time. This activation energy is in agreement with results obtained by other techniques. A ...

313

Hyaluronic acid production by irradiated human synovial fibroblasts  

International Nuclear Information System (INIS)

Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced by the x-ray machine was inhibited by ...

1977-01-01

314

Effects of post-irradiation annealing in alpha-particle bombarded molybdenum  

International Nuclear Information System (INIS)

Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...

315

CuBr blue light emitting electroluminescent thin film devices  

British Library Electronic Table of Contents (United Kingdom)

Abstract Visible blue cathodoluminescence (CL), photoluminescence (PL), x-ray excited optical luminescence (XEOL) and electroluminescence (EL) via Zf free excitonic emission have been obtained from CuBr thin films deposited on glass, Cr coated glass, GaAs and Si substrates. In addition to the Zf emission several peaks corresponding to Cu+ emissions via 3d94s - d10 transitions were observed on the AC EL spectrum at 2.10, 2.7, 3.03, 3.07 and 3.80 eV. X-ray diffraction (XRD) measurements confirmed that the vacuum evaporated CuBr thin films grow preferentially with a (111) orientation irrespective of the substrate. While the AC voltage source was found to have no detrimental effects on CuBr thin films, cathodic deposition of Cu metal via electrolytic decomposition was observed under steady sta...

2011-01-01

316

Coal demineralization with Ca(OH)2. Hydrothermal reaction between Ca(OH)2 and quartz; Ca(OH)2 wo mochiita sekitan no kagakuteki dakkai. Ca(OH)2 to sekitan no suinetsu hanno  

Energy Technology Data Exchange (ETDEWEB)

Coal demineralization mechanism and its optimum condition were studied by hydrothermal reaction between Ca(OH)2 and quartz as a coal demineralization model. In experiment, the mixture of powder quartz and Ca(OH)2 water slurry was subjected to reaction in an autoclave under spontaneous pressure at 175-340{degree}C. After dried in N2 gas atmosphere at 105{degree}C, the reaction product was analyzed by X-ray diffraction, thermo-balance and differential thermal analysis. In measurement of quartz conversion, the specimen was analyzed by X-ray diffraction after removal of bound water by heat treatment at 850{degree}C. The mixture of clean coal deashed by NaOH and a fixed amount of quartz was also used as specimen for experiment. As the experimental result, dicalcium silicate hydrate was mainly produced at 175{degree}C, and the product changed into xonotlite through tobermorite by longer treatment at higher temperature. For ...

1996-10-28

317

Charge redistribution in ion-beam-mixed Pd-Ag alloys  

Science.gov (United States)

Charge flow and valence/d-band behavior in ion-beam-mixed (IBM) Pd1-xAgx (x = 0.5-0.9) alloys have been studied by X-ray photoemission measurement of the valence bands and of core-level binding energy shifts and X-ray absorption near-edge structure. We correlated the observed Ag 3d5/2 core-level shifts in these IBM alloys, relative to the elemental Ag, with the White Line area changes at the Pd and Ag L3-edge to investigate the charge redistribution at the Ag site. The results indicate that there is a decrease in sp-like conduction electron and a negligible change in the number of d-electrons at the Ag site upon alloying. These results are in line with our previous results in which Pd gains d-charges and loses sp-type charges. This electron redistribution due to hybridization in the alloy leads small net charge transfer from the Ag site to the Pd site in accordance with electronegativity predictions. This result is ...

1996-08-01

318

Al/sub 0. 3/Ga/sub 0. 7/P/sub 0. 01/As/sub 0. 99/ GaAs laser heterostructures grown by molecular beam epitaxy  

Science.gov (United States)

Stresses commonly present in AlGaAs/GaAs laser heterostructures were reduced using Molecular Beam Epitaxy grown Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ cladding layers. The Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ alloy was grown using an incident P/sub 2/ flux of roughly-equal1 x 10/sup 14//cm/sup 2/ indicating a sticking coefficient of 0.1 at a substrate temperature of 600 /sup 0/C. X-ray automatic Bragg angle control curvature measurements were used to monitor the residual heteroepitaxial stress. Broadened double crystal x-ray linewidths indicated the occurrence of alloy grading and broadened interfaces. The effects of P concentration and film thickness on stress and on the existence of a misfit dislocation grid are discussed.

1982-09-01

319

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

320

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

321

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

322

Strain evolution in Si substrate due to implantation of MeV ion observed by extremely asymmetric x-ray diffraction  

International Nuclear Information System (INIS)

We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au"2"+ ion at fluence values of 1x10"1"3, 5x10"1"3, and 1x10"1"4/cm"2. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the x rays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the ...

2009-08-15

323

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

324

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

325

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

326

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...

2006-11-13

327

Synthesis, crystal structure and photoluminescence of Eu-#alpha#-SiAlON  

International Nuclear Information System (INIS)

Eu-#alpha#-SiAlON (Eu_m_/_2Si_1_2_-_m_-_nAl_m_+_nO_nN_1_6_-_n) was synthesized with nominal compositions having small m and n values, by firing the powder mixture of Eu_2Si_5N_8, #alpha#-Si_3N_4, AlN, and Al_2O_3 at 1900 "oC for 6 h under 1 MPa nitrogen atmosphere. The ratio of the oxidation state of Eu"2"+/Eu"3"+ was estimated from the X-ray absorption fine structure (XAFS) measurement. The observed X-ray absorption near edge spectrum (XANES) showed that the Eu ion in Eu-#alpha#-SiAlON was mainly in divalent state but also coexisted with a small amount of Eu in the trivalent state. The crystal structure of Eu-#alpha#-SiAlON was refined by the Rietveld analysis of the X-ray powder diffraction patterns. The lattice constants of the samples increased with increasing m and n values. The excitation band of Eu-#alpha#-SiAlON ranged from the ultraviolet to the visible light region and a broad emission band ...

2010-08-20

328

Study of osteoporosis using dual energy X-ray absorptiometry  

Energy Technology Data Exchange (ETDEWEB)

Dual energy X-ray absorptiometry (Hologic QDR-1000) was used to quantitatively analyze the diagnosis and prevention of osteoporosis. The peak bone mineral density (BMD) of the spine appeared in normal men in their twenties and in normal women in their thirties. There was acceleration of bone loss in the 50 to 60 year age bracket (premenopause and postmenopause) in normal women. On the contrary, the peak BMD of the femoral neck in normal men and women appeared in their twenties after which it decreased slightly with age. Comparison showed that the femoral neck BMD of normal women was lower than that of men throughout all ages. The fracture threshold, 0.756 g/cm[sup 2] for the spine, was obtained by scanning 73 females with spinal fractures, the mean BMDs for L2-L4 at the 90th percentile level were used as the fracture threshold. The fracture threshold of femoral neck fracture was the femoral proximal BMD of the 9th decile. Classification by the Public Welfare Silver ...

1992-04-01

329

Micro area analysis and measurement of electronic device material (challenge to utmost limits). Characterization of interface elect`ron structure by photon-and electron-spectroscopies; Denshi debaisu yo zairyo no bisho ryoiki bunseki-keisoku (kyokugen eno chosen). Koshi-denshi bunkoho ni yoru kaimen denshi jotai hyoka  

Energy Technology Data Exchange (ETDEWEB)

A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be investigated by ...

1995-07-20

330

Elastic properties and structural studies on some zinc-borate glasses derived from ultrasonic, FT-IR and X-ray techniques  

Energy Technology Data Exchange (ETDEWEB)

Glasses in the system (1 - x) [29Na{sub 2}O- 4Al{sub 2}O{sub 3}- 67B{sub 2}O{sub 3}]- xZnO (0 {<=} x {<=} 35 mol%), have been prepared by the melt quenching technique. Elastic properties, X-ray and FT-IR spectroscopic studies have been employed to study the role of ZnO on the structure of the investigated glass system. Elastic properties and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz at room temperature. The results showed that the density increases and the molar volume decreases while both sound velocities and the determined glass transition temperatures decrease with increase in x. X-ray and infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of ZnO content. These results are interpreted in terms of the decrease in the N{sub 4} values (fraction of tetrahedral coordinated ...

2009-05-05

331

ESR study of X-ray irradiated rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite  

Energy Technology Data Exchange (ETDEWEB)

X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K{sub 3}Na(SO{sub 4}){sub 2}) matrix or the langbeinite (K{sub 2}Mg{sub 2}(SO{sub 4}){sub 3}) matrix were synthesized by heating the mixture of K{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} or the mixture of K{sub 2}SO{sub 4} and MgSO{sub 4} at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln{sub 2}(SO{sub 4}){sub 3} (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K{sub 2}SO{sub 4}, Na{sub 2}SO{sub 4} and Ln{sub 2}(SO{sub 4}){sub 3} powders or a fixed amount of K{sub 2}SO{sub 4}, MgSO{sub 4} and Ln{sub 2}(S0{sub 4}){sub ...

1992-06-01

332

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

333

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

334

Thermonuclear burst physics with RXTE  

CERN Document Server

Recently we have made measurements of thermonuclear burst energetics and recurrence times which are unprecedented in their precision, largely thanks to the sensitivity of the Rossi X-ray Timing Explorer. In the "Clocked Burster", GS 1826-24, hydrogen burns during the burst via the rapid-proton (rp) process, which has received particular attention in recent years through theoretical and modelling studies. The burst energies and the measured variation of alpha (the ratio of persistent to burst flux) with accretion rate strongly suggests solar metallicity in the neutron star atmosphere, although this is not consistent with the corresponding variation of the recurrence time. Possible explanations include extra heating between the bursts, or a change in the fraction of the neutron star over which accretion takes place. I also present results from 4U 1746-37, which exhibits regular burst trains which are interrupted by "out of ...

2004-01-01

335

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

336

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

337

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

338

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

339

Measurement of the bead profile and microstructural characterization of a CO2 laser welded AISI 904 L super austenitic stainless steel  

British Library Electronic Table of Contents (United Kingdom)

Laser welding of AISI 904 L super austenitic stainless steel using a diffusion cooled slab 3.5kW CO2 laser and employing two different shielding gases, namely argon and helium, was carried out. The laser weld bead profile depends on various parameters such as beam power (BP), travel speed (TS) and focal position (FP) of the laser spot. These parameters have to be selected suitably to obtain the desirable output. The cross sectioned area of the bead profiles measured using an optical microscope to determine the bead width and depth of penetration. X-ray diffraction used for phase identification confirmed that the weld structure was fully austenitic and dendritic. Hardness was observed to increase in the weld bead with respect to the parent metal and it was related to the microstructural ref...

2010-01-01

340

La{sup 3+} modified Al{sub 2}O{sub 3} as a support for CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.

1993-12-31

341

Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K  

International Nuclear Information System (INIS)

The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.

1991-01-01

342

Electrochemical deposition of indium sulfide thin films using two-step pulse biasing  

British Library Electronic Table of Contents (United Kingdom)

Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.

2008-01-01

343

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

344

Chemical, electrical and electrochemical characterization of hybrid organic/inorganic polypyrrole/PW12O40^3^- coating deposited on polyester fabrics  

British Library Electronic Table of Contents (United Kingdom)

A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...

2011-01-01

345

Characterization of (In1−xAlx)2S3 thin films grown by co-evaporation  

British Library Electronic Table of Contents (United Kingdom)

In this paper, it is shown that (In1?xAlx)2S3 thin films can be grown through the co-evaporation of elemental indium, aluminum and sulfur. It is nevertheless observed that the introduction of aluminum within the indium sulfide thin films hinders the crystallites size and even yields almost amorphous films when x is 0.2. The investigations of the optical properties of the films reveal that contrary to what could be expected, the band gap increase is low; the highest values measured do not exceed 2.2eV. However, as suggested by X-ray photoelectron spectroscopy measurements, such widening most probably affects the lower conduction band states.

2010-01-01

346

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Energy Technology Data Exchange (ETDEWEB)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

347

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Science.gov (United States)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

348

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

349

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

350

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

351

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

352

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

353

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

354

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

355

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

356

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

357

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

358

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

359

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

360

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

361

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...

2009-07-01

362

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

363

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

364

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

365

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

366

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

367

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

368

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

369

In situ x-ray diffraction measurement of Pd/sub 2/Si transformation kinetics using a linear position-sensitive detector  

Science.gov (United States)

The x-ray diffraction technique described previously for measurement of growth kinetics of Pd/sub 2/Si layers from their solid state reaction couples has been extended by the use of a one-dimensional position-sensitive detector (PSD). Additionally, the method has been extended to include measurement of the Pd layer. A detailed description of the experimental arrangement and analytical procedures is presented. The kinetics of epitaxial Pd/sub 2/Si film growth were measured in situ over a range of 170--230 /sup 0/C. The PSD results, using data obtained from both the Pd/sub 2/Si and Pd layers, were able to confirm parabolic growth behavior for the Pd/sub 2/Si film. The rate constants followed Arrhenius behavior and yielded an activation energy of E = 1.32 +- 0.07 eV with a prefactor k/sub 0/ = 0.49 cm/sup 2//s for the Pd/sub 2/Si layer analysis and E = 1.34 +- 0.17 eV with a prefactor of 0.72 cm/sup 2//s ...

1988-02-15

370

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including ...

2007-05-07

373

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

374
375

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

376

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

377

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

378

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

380

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

381

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

383

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

384

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

385

Upper Limits from HESS Observations of AGN in 2005-2007  

CERN Document Server

Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.

2007-01-01

386

Synthesis and characterization of myristic acid capped silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

Reduction of silver myristate (AgMy) under mild thermal reaction conditions in a dipolar aprotic solvent i.e. N, N-dimethylformamide (DMF) has been carried out. UV-visible absorption measurements of dried and re-dispersible brown flocculants showed broad features of surface plasmon resonance (SPR) due to silver nanoparticles. The freshly isolated particles showed absorption bands at 414 and 485 nm, respectively, due to inter-particle coupling or clustering of silver ions and silver atoms. X-ray diffraction (XRD) pattern of fcc zero-valent silver resulted in crystallite size of about 10 nm. Scanning electron microscopy (SEM) revealed formation of rod shaped silver with increasing reaction temperature. Thermal analysis (TGA) showed about 10% weight loss due to organic capping.

2008-08-15

387

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

388

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a stable cation.

2008-01-01

389

Study on the electrochemical properties of MgNi-CuO hydrogen storage composite materials  

Energy Technology Data Exchange (ETDEWEB)

To study the effect of CuO on the electrochemical properties of MgNi alloy, the MgNi-xCuO (x = 3, 5 and 10 wt%) composites were prepared by ball-milling method. The X-ray diffraction (XRD) analysis showed that the structures of the composites were amorphous. The cycle stability of the composites was improved compared to pure MgNi alloy due to the enhancement of the anti-corrosion property in the alkaline electrolyte, and the composite with 5 wt% CuO ball-milled for 15 h exhibited the best performance. Electrochemical impedance spectroscopy (EIS) and potential-step measurements indicated that the electrochemical kinetics of the composites was improved.

2009-07-29

390

Structural changes in amorphous Pd/sub 80/Si/sub 20/ by neutron irradiation  

Science.gov (United States)

Amorphous Pd/sub 80/Si/sub 20/ was irradiated with fast neutrons (>1 MeV) to a fluence of 5 x 10/sup 20/ neutrons/cm/sup 2/. X-ray scattering intensities were measured before and after the irradiation with monochromatic Cu-K..cap alpha../sub 1/ rays. Scattered intensities for s>0.4 A/sup -1/ (s=2 sintheta/lambda) proved unaffected, while intensities were found remarkably enhanced for s<0.4 A/sup -1/ after the irradiation, i.e., in the small-angle region and the leading edge of the first halo. The results are discussed in relation to the structural anomalies in amorphous solids.

1977-10-01

391

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.

2004-02-28

392

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).

1986-01-01

393

Self-organization and electrical properties of Head-to-Tail poly(3-hexylthiophene) in Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)

1997-01-01

394

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

395

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

396

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

397

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

398

Pore-structure models of hydraulic conductivity for permeable pavement  

British Library Electronic Table of Contents (United Kingdom)

SummaryPermeable pavement functions as a porous infrastructure interface allowing the infiltration and evaporation of rainfall-runoff while functioning as a relatively smooth load-bearing surface for vehicular transport. Hydraulic conductivity (k) of permeable pavement is an important hydraulic property and is a function of the pore structure. This study examines k for a cementitious permeable pavement (CPP) through a series of pore-structure models. Measurements utilized include hydraulic head as well as total porosity, (t), effective porosity (e), tortuosity (Le/L) and pore size distribution (PSD) indices generated through X-ray tomography (XRT). XRT results indicate that the permeable pavement pore matrix is hetero-disperse, with high tortuosity and t!=e. Power law models of k-t and k-e...

2011-01-01

399

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)

2009-11-01

400

Plasma nitriding of microalloyed steel  

Energy Technology Data Exchange (ETDEWEB)

Microalloyed or high strength low alloy (HSLA) steels are carbon-manganese steels containing small amounts of Nb, V or Ti. The excellent mechanical properties of these alloys, particularly high yield strength, usually obviate the need for expensive quench and tempering operations. Furthermore, the presence of a significant amount of nitride-forming elements in some microalloyed steels has generated interest in the applicability of these alloys as a new generation of nitriding steels. In this paper, a study of the plasma nitriding behaviour of a commercially available microalloyed steel MAXIMA{sup TM} is reported. A comparison is made with a traditional quenched and tempered nitriding steel (En19), plasma nitrided under similar conditions. Optical and scanning electron microscopy in conjunction with microhardness measurements and X-ray diffraction were utilized to characterize the nitrided surfaces. The observed differences in the thickness and ...

1995-03-01

401

PIXE analysis of chinese chicken-blood stone  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al{sub 2}O{sub 3} and SiO{sub 2}. The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)

1999-07-01

402

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within the crystals.

2006-10-29

403

Optimal design and preparation of beta-SiAlON multiphase materials from natural clay  

International Nuclear Information System (INIS)

Beta-SiAlON powders have been synthesized using natural clay containing kaolin and quartz by carbothermal reduction and nitridation (CRN), then beta-SiAlON bonded corundum multiphase materials have been sintered using the as prepared powders. The results indicated that both the holding time and sintering temperature are relatively significant in accordance with optimal analysis by orthogonal method. Reaction process can be briefly interpreted by means of X-ray Diffraction and Difference Temperature Analysis as well as phase diagram principle. Bending strength and bulk density were measured in SiAlON in situ bonded corundum materials with doped various sintering agents. Furthermore, the relevant mechanical properties and microstructure were discussed in detail.

404

On plasma nitriding of steels  

Energy Technology Data Exchange (ETDEWEB)

With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...

2000-02-01

405

Morphology and properties of silane-modified montmorillonite clays and clay/PBT composites  

British Library Electronic Table of Contents (United Kingdom)

Commercially available organoclay (Closite 30B) was modified by using 3-aminopropyltriethoxysilane (APS) via a silylation reaction. Sodium clay (Closite Na) was treated by APS directly as a control. Such modified clays were further melt-compounded with polybutylene terephthalate (PBT). The morphology and properties of the modified organoclays were characterized with X-ray diffraction (XRD), transmission electrical microscopy (TEM), Infra-red spectroscopy, contact angle measurement, and thermogravimetric analysis (TGA). The effects of modified clays on the crystallization behavior of PBT were characterized by differential scanning calorimetry. The basal spacing of Closite Na was enlarged from 1.01 to 1.41 nm after APS treatment, indicating that the APS was intercalated into the clay interga...

2008-01-01

406

Kinetics of pore coarsening in glassy carbon  

Energy Technology Data Exchange (ETDEWEB)

One third of the microstructure of glassy carbon (GC) consists of closed pores. Density measurements indicate that the total pore volume depends only on the heat treatment temperature and not on the heat treatment time, a characteristic of coarsening. The kinetics of coarsening of these pores on heat treatment has been investigated by analyzing the changes in specific surface area of the pores as determined by the small angle X-ray scattering (SAXS) technique. A part of the surface area change is due to thermal expansion induced microcracking. Both the superposition method after correcting the thermal expansion induced surface area change and the curve fitting method give an activation energy of 64 +/- 10 kcal/mole. This value is compared with the activation energies of various rate processes in graphite. A model of coarsening of the pores based on a vacancy migration mechanism is proposed.

1981-01-01

407

Ion beam induced damage and element loss during a microanalysis of biological tissue  

Energy Technology Data Exchange (ETDEWEB)

Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).

1991-03-01

408

Investigation into some tribological properties of plasma nitrided hot-worked tool steel AISI H11  

Energy Technology Data Exchange (ETDEWEB)

Interest in the tribological properties of plasma nitriding has increased substantially over the past years because plasma nitriding provides a high nitride depth and improved hard facing. The present study examines the tribological properties of AISI H11 plasma nitrided, hot-worked steel. Different nitriding temperatures and durations were considered. Characterization of the composite structures was investigated with wear tests, x-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), and microhardness tests. The depth profile of the nitrided zone was measured using the nuclear reaction analysis (NRA) technique. Plasma nitriding affected the microhardness, wear properties, and morphology considerably. Increase in process temperature increased the nitride zone depth.

1996-04-01

409

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

410

High coercivity in Nd-Fe-Al-Co-B alloys prepared by mechanical milling  

Energy Technology Data Exchange (ETDEWEB)

Nd{sub 40}Fe{sub 30}Al{sub 10}Co{sub 15}B{sub 5} alloys were fabricated by high energy ball milling method under various conditions. Microstructure of the alloys was investigated by X-ray diffraction and electron microscopy techniques. Magnetic properties were characterized by hysteresis and thermomagnetic measurements. The high coercive fields up to 2.36 T have been observed on the samples consisting of Nd{sub 2}(Fe,Co,Al){sub 14}B, Nd{sub 6}(Fe,Co,Al){sub 14} and Nd crystallites imbedded in a residual amorphous matrix.

2008-02-15

411

Exploring the binding of the strong organic acceptor F{sub 4}TCNQ to coinage metals  

Energy Technology Data Exchange (ETDEWEB)

Organic/metal interface properties are of high interest for the application of molecular (sub)monolayers to modify surface properties. They are applied for, e.g., molecular electronics, chemical sensing, or the tuning of injection barriers in organic electronic devices. We present a joint theoretical and experimental study of F{sub 4}TCNQ adsorbed on Cu(111). The electronic and structural properties were determined by ultraviolet photoelectron spectroscopy (UPS) and X-ray standing wave (XSW) measurements. To better understand the complex process of binding, we modelled the system using density-functional theory. We find forward-donation from the lone pairs of the molecule into metallic states and back-donation from the metal into the LUMO of the molecule. The data on Cu(111) are compared to F4TCNQ on Au(111) and Ag(111) as well as to investigations of pyrenetetraone on various coinage metals.

2008-07-01

412

Estimating hip fracture risk from digital x-ray image data  

International Nuclear Information System (INIS)

The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.

413

Environmentally conscious sintered glass-ceramics  

Energy Technology Data Exchange (ETDEWEB)

Sintered glass-ceramics have been produced using municipal incinerator solid residues and glass cullet or an inert waste, from feldspars processing, as sintering aids. The capability of three different mixtures, either previously vitrified or not, to be sintered was investigated by means of linear shrinkage, water absorption and bulk density measurements, and by X-ray diffraction analysis and scanning electron microscopy observations. Particular attention has been addressed to the study of particle size effect on the sintering process. The conclusions that can be drawn from the experimental study are that the preliminary vitrification step is essential in order to obtain a dense sintered glass-ceramic product in the 850-1050 C temperature range developing silicate crystalline phases. The optimal powder particle size that confers a good densification degree was found to be < 45 {mu}m. (orig.)

2002-07-01

414

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

415

Electrical properties of antimony doped PLZT ceramics prepared by mixed-oxide route  

International Nuclear Information System (INIS)

Ferroelectric [Pb_0_._9_2(La_1_-_zSb _z)_0_._0_8][Zr_0_._6_0Ti_0_._4_0]O_3 for z = 0.0, 0.3, 0.6, 0.9 and 1 were prepared from their constituent oxides by a solid state reaction technique. The powders were calcined in the temperature range of 1000 deg. C for 6 h. Phase formation, crystal structure and lattice parameter were investigated by X-ray diffraction (XRD) technique. The compacts were sintered at 1250 deg. C for 2 h and their dielectric, ferroelectric and conductive properties were measured. The ferroelectric behavior of the doped samples was studied from their hysteresis loop.

2006-12-21

416

Effect of pressure on iodine complexes, 1  

International Nuclear Information System (INIS)

Absorption spectra of the visible I_2 band of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 3300 bar at 25"0C. The equilibrium constants and volume changes accompanying complex formation, the molar extinction coefficients and the absorption maxima have been estimated. The volume changes were found comparable with those estimated from the X-ray data of the I_2 complexes in the crystalline state. The enhancement of the molar extinction coefficient and the blue shift of the visible I_2 band with increasing pressure have been established. The results suggest a decrease in the bond distance between an n-donor and I_2, compared with the spectroscopic properties of the I_2 complex at 1 bar. The decrease has been estimated as 0.008 nm with increasing pressure up to 3300 bar. (author).

1979-01-01

417

Effect of alumina incorporation on restricting grain growth of nanocrystalline tin(IV) oxide  

British Library Electronic Table of Contents (United Kingdom)

In this project, nanocrystalline SnO2 powders were successfully prepared by (a) citrate sol-gel and (b) direct precipitation methods. Powders were characterized using thermal analysis techniques (DTA-TG-DSC), X-ray powder Diffraction (XRD), surface area (BET) and electrical conductivity measurements. XRD patterns showed the presence of the cassiterite structure. SnO2 particles, prepared through sol-gel method exhibit crystallite sizes in the range from 3.1 to 22.3 nm when the gel is heat treated at different temperatures up to 900?C. SnO2 nanocrystallites prepared by the precipitation method are comparatively larger in size. The higher specific surface area was obtained for the powder prepared using sol-gel method and the obtained average grain size (d) is relatively large compared with th...

2010-01-01

418

Effect of Mo on the composition and electronic properties of the passive films formed on stainless steels at 350 C  

Energy Technology Data Exchange (ETDEWEB)

The effect of Mo addition as an alloying element to stainless steel alloys is investigated by capacitance (Mott Schottky approach), and photoelectrochemistry measurements. Complementary studies were made using Auger electron spectroscopy and X-ray photoelectron spectroscopy. The Mott-Schottky approach and the photoelectrochemical studies showed that the presence of Mo as an alloying element affects the semiconductive properties of the oxide films. The analytical results have shown that the oxide films formed on stainless steels are composed by an external Fe rich region and an inner Cr rich region. No significant amount of Mo was found in the outer layers of the film. The presence of Mo leads to an increase of the chromium content in the inner layers of the film, although without increasing the film thickness. (orig.) 30 refs.

1998-12-31

419

Effect of Mo on the composition and electronic properties of the passive films formed on stainless steels at 350 C  

International Nuclear Information System (INIS)

The effect of Mo addition as an alloying element to stainless steel alloys is investigated by capacitance (Mott Schottky approach), and photoelectrochemistry measurements. Complementary studies were made using Auger electron spectroscopy and X-ray photoelectron spectroscopy. The Mott-Schottky approach and the photoelectrochemical studies showed that the presence of Mo as an alloying element affects the semiconductive properties of the oxide films. The analytical results have shown that the oxide films formed on stainless steels are composed by an external Fe rich region and an inner Cr rich region. No significant amount of Mo was found in the outer layers of the film. The presence of Mo leads to an increase of the chromium content in the inner layers of the film, although without increasing the film thickness. (orig.)

1997-08-25

420

Double peak effect in microdosimetric proportional counters and its interpretation  

Energy Technology Data Exchange (ETDEWEB)

In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.

1989-01-01

421

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

422

Determination of ratios of emission probabilities of Auger electrons and K-L-shell radiative vacancy transfer probabilities for 17 elements from Mn to Mo at 59.5keV  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.

2006-01-15

423

DBD Surface Modification of Polymers in Relation to the Spatial Distribution of Reactive Oxygen Species  

British Library Electronic Table of Contents (United Kingdom)

The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...

2011-01-01

424

Bandgap properties of the indium sulfide thin-films grown by co-evaporation  

British Library Electronic Table of Contents (United Kingdom)

In the present study the optical properties of co-evaporated indium sulfide thin films are investigated. Before being optically characterized, the composition as well as the crystalline properties of the film have been checked with the help of energy dispersive spectroscopy (EDX) and X-Ray diffraction (XRD) analyses. The optical absorption coefficient ? of this indium sulfide film has been deduced from reflectivity R(?) and transmission T(?) measurements. The fit of the curve representing ?(h?) suggests that the ?-In2S3 has an indirect bandgap of 2.01?eV. Density functional theory (DFT) calculations are performed on this indium sulfide compound, using TB-LMTO code. Through these band structure investigations, an indirect bandgap is predicted as observed experimentally. The top of the valen...

2009-01-01

425

Asymmetric Hydrogenation with Highly Active IndolPhos-Rh Catalysts: Kinetics and Reaction Mechanism  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of the IndolPhos-Rh-catalyzed asymmetric hydrogenation of prochiral olefins has been investigated by means of X-ray crystal structure determination, kinetic measurements, high-pressure NMR spectroscopy, and DFT calculations. The mechanistic study indicates that the reaction follows an unsaturate/dihydride mechanism according to Michaelis-Menten kinetics. A large value of KM (KM=5.01+-0.16 M) is obtained, which indicates that the Rh-solvate complex is the catalyst resting state, which has been observed by high-pressure NMR spectroscopy. DFT calculations on the substrate-catalyst complexes, which are undetectable by experimental means, suggest that the major substrate-catalyst complex leads to the product. Such a mechanism is in accordance with previous studies on the mechanism...

2010-01-01

426

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

427

A study on rf plasma nitriding at a constant power in different H_2-N_2 mixtures at different temperatures  

International Nuclear Information System (INIS)

Austenitic stainless steel AISI 304 has been nitrided by radio frequency (rf) plasma containing various nitrogen-hydrogen gas mixtures, in order to study the effect of hydrogen on structure and magnetic properties of the formed compound layer. The thermal temperature has been measured at the vicinity of the samples. The compound layer thus produced has been characterized using, X-ray diffractometer and vibration sample magnetometer. Providing the total pressure of nitrogen and hydrogen is held constant, the addition of hydrogen up to 50% gives new structural phases. The magnetization values of the plasma treated samples are strongly dependent on the percentage of H_2 in the gas phase. An excessive amount of hydrogen (#approx#75%) on the other hand, retards the nitriding process. The surface temperature of the sample and plasma condition is crucial factors for nitriding process.

2006-04-15

428

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

429

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

430

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

431

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

432

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

433

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

434

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

435

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

436

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

437

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

438

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of ...

2006-03-01

439

Multi-Phase Fracture-Matrix Interactions Under Stress Changes  

Energy Technology Data Exchange (ETDEWEB)

The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with ...

2005-12-07

440

Two dimensional power spectral density measurements of X-rayoptics with the Micromap interferometric microscope  

Energy Technology Data Exchange (ETDEWEB)

A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The ...

2005-05-12

441

Direct observation of ordered orbital of YTiO{sub 3} by the X-ray magnetic diffraction technique  

Energy Technology Data Exchange (ETDEWEB)

X-ray magnetic diffraction (XMD) technique was applied to an orbital ordering compound of ferromagnetic YTiO{sub 3} for the first time. The orbital-magnetic form factor {mu} {sub L}(k) and the spin-magnetic form factor {mu} {sub S}(k) were independently measured by utilizing the LS separation ability of the XMD. The {mu} {sub L}(k) was measured for ten reciprocal-lattice points. No significant values of the {mu} {sub L}(k) were observed for most of the reciprocal-lattice points within the estimated statistical errors, which suggested quenching of the orbital moment. The {mu} {sub S}(k) was measured for 22 reciprocal-lattice points. Fourier synthesis of the {mu} {sub S}(k) gave the spin density distribution m {sub S}(r) in the real space. The obtained m {sub S}(r) map shows the characteristic feature of the electron distribution of 3d electron in the t{sub 2g} state of a Ti atom coordinated by O{sup 2-} ...

2005-08-15

442

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

443

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

444

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

445

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

446

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

447

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

448

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

449

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

450

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

451

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak ...

2005-01-01

452

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, ...

2008-05-22

453

Strain enhanced electron spin polarization observed in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements ...

1991-05-06

454

Physical properties of Ti/sub 50/Be/sub 40/Zr/sub 10/ glass  

Science.gov (United States)

Continuous metallic glass ribbons were produced by mejans of liquid-quenching at rates >10/sup 50/C/s. The ribbons, typically 30 ..mu..m thick and 1 to 2 mm wide, were determined to be glassy by X-ray diffraction (XRD) employing CuK..cap alpha.. and MoK..cap alpha.. radiation. Mechanical properties of the as-quenched product were determined by measurements of hardness, tensile strength and Young's modulus. The Vicker's diamond pyramid microhardness (H/sub V/) was measured on epoxy mounted samples using a Lietz Miniload instrument with a 100 g load. Tensile tests were conducted in an Instron machine using specimens which were hand-polished to produce smooth, parallel sides. Young's modulus (E) is given by the relationship rho V/sub E/sup 2//. V/sub E/, the velocity of extensional mode waves, was measured by the pulse-echo technique using a Panametrics Intervalometer and ...

1977-09-01

455

Ozone production at the National Synchrotron Light Source  

International Nuclear Information System (INIS)

Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene ...

1998-09-20

456

Ozone production at NSLS  

International Nuclear Information System (INIS)

Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10/sup 12/ and 10/sup 15/ eV/sup . /cm/sup -3 . /sec/sup -1/. The measured ozone half-life was 37+-2 min. The measured G-value was 2.69+-0.14 mol/100 eV and the ozone destruction factor k was less than 5 x 10/sup -19/cm/sup 3//eV. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppm ACGIH TLV can be generated in the experimental hutches but can readily be controlled. ...

457

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of ...

1979-01-01

458

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section ...

1982-12-01

459

Establishing a Connection Between Active Region Outflows and the Solar Wind: Abundance Measurements with EIS/Hinode  

CERN Document Server

One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December ...

2010-01-01

460

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement ...

2000-01-01

461

XRF analysis of rock and sediment using standard rock samples  

Energy Technology Data Exchange (ETDEWEB)

A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm/sup -2/, and then 1 g of powdered sample (0.08 g cm/sup -2/) was placed on the disk and repressed at 1.6 t cm/sup -2/. X-ray measurements were performed for total XRF intensity (I/sub p/) at the characteristic line of each element and background intensity (I/sub b/) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I/sub p/ - I/sub b/ vs. concentration for Ca, Na and Pb and by the plot of I/sub p//I/sub b/ ratio vs. ...

1987-03-01

462

XRF analysis of rock and sediment using standard rock samples  

International Nuclear Information System (INIS)

A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm"-"2, and then 1 g of powdered sample (0.08 g cm"-"2) was placed on the disk and repressed at 1.6 t cm"-"2. X-ray measurements were performed for total XRF intensity (I_p) at the characteristic line of each element and background intensity (I_b) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I_p - I_b vs. concentration for Ca, Na and Pb and by the plot of I_p/I_b ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, ...

463

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K{beta}-to-K{alpha} X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

K{beta}-to-K{alpha} X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr{sub 0.26}Fe{sub 0.74}, Cr{sub 0.80}Co{sub 0.20} and Ti{sub 0.80}Cr{sub 0.20} alloys have been measured following excitation by 59.54 keV {gamma}-rays from a 7400 MBq (200 mCi) {sup 241}Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K{beta}-to-K{alpha} intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the ...

2002-10-01

464

Valence electronic structure of Ti, Cr, Fe and Co in some alloys from K#beta#-to-K#alpha# X-ray intensity ratio studies  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# X-ray intensity ratios of Ti, Cr, Fe and Co in pure metals and in Cr_0_._2_6Fe_0_._7_4, Cr_0_._8_0Co_0_._2_0 and Ti_0_._8_0Cr_0_._2_0 alloys have been measured following excitation by 59.54 keV #gamma#-rays from a 7400 MBq (200 mCi) "2"4"1Am point-source. The valence electronic structure of Ti, Cr, Fe and Co in the samples have been evaluated by the comparison of the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations performed for various electronic configurations of these metals. The 3d-electron populations obtained for pure metallic Ti, Cr, Fe and Co agree well with the results of band structure calculations of Papaconstantopoulos (Handbook of band structure of elemental solids, Plenum Press, New York, 1986). Our analysis indicates significant increase of 3d-electron population of Ti, Cr and Fe in the alloys with respect to the pure metals, ...

2002-10-01

465

Synthesis, crystal structure and nonlinear optical property of Rb3V5O14  

International Nuclear Information System (INIS)

The new nonlinear optical crystal Rb3V5O14 has been synthesized by solid state reaction and characterized by single-crystal X-ray diffraction, IR and thermogravimetric analysis. The crystal Rb3V5O14 crystallizes in the trigonal system with space P31m (No. 157), a=b=8.7134(12) A, c=5.2807(11) A and ?=90o, ?=90o, ?=120o, Z=1, ?=3.516 g/cm3. It is a layered structure that is very flat and strongly parallel to c. The V5O14 layer structure consists of corner-linked square and triangular pyramids. The layers are separated by Rb+ ions, which fit equally well on the V5O14 layer. The Kurtz powder SHG measurement, using 1064 nm radiation, showed that the second-harmonic generation efficiency of Rb3V5O14 is about two times that of KDP. -- Graphical abstract: The new nonlinear optical crystal Rb3V5O14 has been synthesized by solid state reaction and characterized by single-crystal X-ray diffraction, IR and thermogravimetric analysis. ...

2010-12-01

466

RF plasma nitriding of severely deformed iron-based alloys  

International Nuclear Information System (INIS)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher ...

2003-05-15

467

Microstructure and electrical properties of iron oxide thin films deposited by spray pyrolysis  

International Nuclear Information System (INIS)

Microstructure and electrical properties of iron oxide Fe_2O_3 thin films prepared by spray pyrolysis method have been experimentally characterized. The effect of substrate temperature as well as deposition time on the structural features (crystallite size and microstrain) and electric resistivity of these films has been investigated. X-ray diffraction (XRD) and scanning electron microscope (SEM) characterized the structure study. The results of X-ray diffraction showed that with increasing substrate temperature bias the film structure changed from amorphous to crystalline at the same deposition time. At a substrate temperature of 350 deg. C and low deposition time, #alpha#-Fe_2O_3 appears almost in amorphous form. With rising the substrate temperature and deposition time, the crystallinity was improved. At T_s_u_b>350 deg. C, a well-crystallized rhombohedral phase of #alpha#-Fe_2O_3 was obtained. Single order Voigt profile method has been ...

2004-01-15

468

K#beta#-to-K#alpha# x-ray intensity ratio studies of the valence electronic structure of Fe and Ni in Fe_xNi_1_-_x alloys  

International Nuclear Information System (INIS)

K#beta#-to-K#alpha# x-ray intensity ratios of Fe and Ni in pure metals and in Fe_xNi_1_-_x alloys (x=0.20, 0.50, 0.58) exhibiting similar crystalline structure have been measured following excitation by 59.54 keV #gamma# rays from a 200 mCi "2"4"1Am point source to understand why the properties of the Fe_xNi_1_-_x (x=0.2) alloy are distinct from other alloy compositions. The valence electronic structure of Fe and Ni in the samples has been evaluated by comparing the measured K#beta#-to-K#alpha# intensity ratios with the results of multiconfiguration Dirac-Fock calculations. Significant changes in the 3d electron population (with respect to the pure metal) are observed for Fe and Ni for certain alloy compositions. These changes can be explained by assuming rearrangement of electrons between 3d and (4s,4p) band states of the individual metal atoms. It has been found that the valence electronic structure of the ...

2001-02-15

469

Use of Teflon-embedded calcium sulphate: dysprosium thermoluminescent dosimeters for chest radiography  

Energy Technology Data Exchange (ETDEWEB)

As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of ...

1987-12-01

470

The pre-outburst flare of the A 0535+26 August/September 2005 outburst  

CERN Document Server

We study the spectral and temporal behavior of the High Mass X-ray Binary A 0535+26 during a `pre-outburst flare' which took place ~5 d before the peak of a normal (type I) outburst in August/September 2005. We compare the studied behavior with that observed during the outburst. We analyse RXTE observations that monitored A 0535+26 during the outburst. We complete spectral and timing analyses of the data. We study the evolution of the pulse period, present energy-dependent pulse profiles both at the initial pre-outburst flare and close to outburst maximum, and measure how the cyclotron resonance-scattering feature (hereafter CRSF) evolves. We present three main results: a constant period P=103.3960(5)s is measured until periastron passage, followed by a spin-up with a decreasing period derivative of Pdot=(-1.69+/-0.04)x10^(-8)s/s at MJD 53618, and P remains constant again at the end of the main outburst. The spin-up ...

2008-01-01

471

Structural changes in amorphous Pd_8_0Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys caused by neutron irradiation  

International Nuclear Information System (INIS)

The present work is to study effects of neutron irradiation on the structure of amorphous Pb_8_0 Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys by using X-ray diffraction techniques. differential scanning calorimertry (DSC) and internal friction measurements. The irradiation will produce obvious changes in the pair correlation function g(r) and radial distribution function RDF (r). The increase of crystallization temperature (Tx) and enthalpy of two specimens were found by DSC measurements after irradiation. The results of internal friction measurement show that the internal friction of the irradiated Pd_8_0Si_2_0 alloy is higher than that of the unirradiated in the temperature range of T

472

Properties of superconducting Cu-rich composites containing V_3Si or V_3Ga  

International Nuclear Information System (INIS)

Superconducting Cu-rich composites containing the A-15 compounds V_3Si or V_3Ga were made by the ''Tsuei'' process (melting into ingots followed by cold working and heat treatment). Superconducting transition temperatures of the composites were measured. X-ray diffraction analyses were performed. Microstructures were studied using both the optical metallograph and the scanning electron microscope. For some composites containing V_3Ga, the critical current densities as functions of transverse magnetic field up to 60 kG, and as functions of temperature from 4.2 to 12"0K were measured. It was found that the Tsuei process does not work for the composites containing V_3Si, but works satisfactorily for V_3Ga; reasons are discussed. Relations between measured properties and various metallurgical factors such as alloy compositions, cross-section reduction ratios, and heat treatment are discussed. The mechanism ...

473

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

474

PIXE-PIGE analysis of some Indian medicinal plants  

Energy Technology Data Exchange (ETDEWEB)

The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in ...

2010-06-15

475

Kapitza conductance of the (100) surface of copper  

International Nuclear Information System (INIS)

Measurements of the Kapitza conductance to liquid helium II across the (100) surface of single crystals of copper are presented. The temperature range of these measurements was 1.6-- 2.1 K. The sample surfaces were subjected to several different treatments. Some surfaces were cleaned by low-energy argon ion bombardment, annealed in an ultrahigh-vacuum system, and preserved under vacuum until purified liquid helium was admitted. Other surfaces were intentionally damaged by machining and/or exposure to the atmosphere. The conductance after these latter treatments was found to be about a factor of three higher than that of the more ideally cleaned and annealed surfaces, and a significant difference in the temperature dependence of the conductance was also observed. Conductances were reproducible for similarly treated surfaces and correlated with surface damage determined by x-ray diffraction. The relationship of these results ...

476

Improved adhesion for thermoplastic polymers using oxyfluorination  

Energy Technology Data Exchange (ETDEWEB)

Industrial applications of thermoplastic polymers are often limited by their poor adhesion properties. In this work the effect of surface oxyfluorination on the adhesion properties was investigated for polyethylene (PE), polyoxymethylene (POM), polybutylene terephthalate (PBT) and polyamide 6 (PA6). The adhesive joint strength was quantified using lap-shear tests. These results were correlated with the changes in the chemical composition of the surface, determined by X-ray photoelectron spectroscopy (XPS), in the surface free energy, measured by the contact angle method, and in the topography, using white-light confocal microscopy. The adhesive strength is strongly improved for all four polymers, but the degree of this increase depends on the polymer type. The surface free energy shows a similar trend for all four polymers. A high surface free energy exceeding 50 mN/m was observed after oxy-fluorination, whereby the polar component was strongly ...

2008-03-15

477

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the response of the complete ...

478

Constraining the Dark Energy Equation of State using Alternative High-z Cosmic Tracers  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII galaxies which can be detected up to very large redshifts, z~4, as an alternative to supernovae type Ia, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of z~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...

2009-01-01

479

Alternative High-z Cosmic Tracers and the Dark Energy Equation of State  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & \\Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII-like starburst galaxies, as an alternative to SNIa, which can be detected up to very large redshifts, z~4, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of ~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...

2009-01-01

480

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers  

International Nuclear Information System (INIS)

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and ...

2010-08-26

481

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its ...

2001-03-01

482

Surgical adjuvant therapy in colon carcinoma: a human tumor spheroid model for evaluating radiation sensitizing agents  

International Nuclear Information System (INIS)

HT-29 human colon tumor cells growing as spheroids have been evaluated as a model system for measuring the response of human colon tumor cell to antineoplastic agents. HT-29 cells have been capacity to form spheroids up to 1 mm or more in diameter when grown in spinner culture. The multicellular HT-29 spheroids develop hypoxic centers reflecting the cellular conditions found in human cancer treatment, i.e., nutritionally deficient hypoxic cells that are felt to be a significant source of both radiation and chemotherapy clinical treatment failures. Spheroids of increasing size were radiated and then dispersed into single cells for colony survival assay. Compared with irradiated single cell suspensions, the spheroid cells demonstrated a significant increase in radioresistance. Growing spheroids developed a complex radiation survival curve which was variable with respect to size of the spheroid. The drug 5-Fu was studied to examine in a preliminary fashion its ...

483

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...

2007-04-07

484

Metal contacts to n-GaN  

International Nuclear Information System (INIS)

Al, Au, Ti/Al and Ti/Au contacts were prepared on n-GaN and annealed up to 900 deg. C. The structure, phase and morphology were studied by cross-sectional transmission and scanning electron microscopy as well as by X-ray diffraction (XRD), the electrical behaviour by current-voltage measurements. It was obtained that annealing resulted in interdiffusion, lateral diffusion along the surface, alloying and bowling up of the metal layers. The current-voltage characteristics of as-deposited Al and Ti/Al contacts were linear, while the Au and Ti/Au contacts exhibited rectifying behaviour. Except the Ti/Au contact which became linear, the contacts degraded during heat treatment at 900 deg. C. The surface of Au and Ti/Au contacts annealed at 900 deg. C have shown fractal-like structures revealed by scanning electron microscopy. Transmission electron microscopy and XRD investigations of the Ti/Au contact revealed that Au diffused into the n-GaN layer at ...

2006-11-15

485

Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique  

Science.gov (United States)

An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, C, and F were detected at the Pd/sub ...

1986-05-15

486

Growth characteristics of ZrO_2 insulation coatings on Ag/AgMg sheathed Bi-2212 superconducting tapes  

International Nuclear Information System (INIS)

We have investigated the growth behaviors of high temperature compatible ZrO_2 insulation coatings on Ag and AgMg sheathed Bi_2Sr_2Ca_1Cu_2O_x superconducting tapes depending on number of dipping and thermal conditions. The coatings were fabricated on long-length superconducting tape substrates using a solution derived from Zr tetrabutoxide, solvent and chelating agent for high magnetic field magnets. The layer-on-layer growth behaviors were characterized by environmental scanning electron microscope (ESEM), energy dispersive spectroscopy (EDS), X-ray maps and X-ray diffraction (XRD). This research showed that the ZrO_2 coatings were regularly grown on Ag-based tape substrates and coating thickness increased with increasing number of dipping. It was found that ceramic oxides formed at temperature range 450 and 550 deg. C. The final coating thickness changed between 6 and 8 #mu#m after annealing process. Resistance of insulation ...

2004-07-15

487

Grazing incidence X-ray diffraction and neutron reflection studies of semi-crystalline polymer surfaces and interfaces[Polymers; Crystallisation behaviour  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the crystallisation behaviour of polymers near to a free surface or a buried interface. The properties of polymers are expected to differ significantly near to an interface (either with air or another polymer), due to the contributions of (a) chain configurations induced at the interface, and (b) different mobilities between interfacial regions and the bulk of the sample. For a semi-crystalline polymer, properties such as the degree of crystallinity and the crystallisation kinetics may be enhanced near to a free surface. Grazing incidence x--ray diffraction (GIXD) is used to investigate such effects in poly(ethylene terphthalate) (PET), showing that a lower crystallisation temperature is obtained at the surface, and the crystallisation kinetics are faster at the surface for all temperatures. It is proposed that in thin films of PET, this surface-induced ordering provides nucleation sites for crystallisation in the bulk. GIXD is also ...

2002-07-01

488

Corrosion properties of thin molybdenum silicide films  

Energy Technology Data Exchange (ETDEWEB)

The corrosion properties of sputtered molybdenum and molybdenum silicide films in hydrochloric acid (HCl) have been studied by means of potentiodynamic measurements. Contributions from the substrate to the corrosion behaviour was avoided by depositing the films on inert aluminium oxide (Al{sub 2}O{sub 3}). The compositions studied were Mo, MoSi{sub 0.58}, MoSi{sub 1.04}, MoSi{sub 1.4} and MoSi{sub 1.9-2.1}. Characterisation of the samples was made by X-ray diffraction (XRD) and scanning electron microscopy (SEM) before and after corrosion. X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) were used to analyse the polarised films. Corrosion of Mo{sub 3}Si was found in the molybdenum-rich samples (MoSi{sub 0.58}) containing the two phases Mo{sub 3}Si and Mo{sub 5}Si{sub 3}. Polarisation curves for these films showed one passivation peak at 228 mV vs. the saturated calomel electrode (SCE). The ...

1997-11-25

489

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT ...

2004-12-07

490

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

491

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

492

XPS study on the correlation between chemical state and oxygen-sensing properties of an iron oxide thin film  

International Nuclear Information System (INIS)

We have studied the correlation between the chemical state and the oxygen-sensing properties of an iron oxide thin film using a setup that allows simultaneous sensor resistance measurements and X-ray photoelectron spectroscopy (XPS) data acquisition. The gas exposures were performed at the highest operating pressure of the XPS spectrometer at a controlled sample temperature which allows direct comparison between the sensor response and the chemical state of the surface. The iron oxide film was modified by a sequence of argon ion sputtering steps and the induced changes in the chemical state, resistance, and sensitivity to oxygen were investigated. The sputtering was found to reduce the iron from the Fe"3"+ to the Fe"2"+ state and to decrease the sensor resistance. The measured sensitivity to oxygen first increased by a factor of two but then collapsed to its original level. The mechanism for oxygen sensing was found to be ...

2007-10-15

493

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background ...

2009-05-01

494

SIMS and XRD measurements for the critical review of carbon diffusivity derivation from hardness profiles  

Energy Technology Data Exchange (ETDEWEB)

Microhardness decarburization profiles are often used in the industry to estimate the carbon distribution in steels. For quantitative evaluation, an analysis based on diffusion theory must be performed, the fundamentals and mathematical basics of which are presented. If the relationship between hardness and carbon content is known, microhardness-distance curves of steels can be analyzed in this way. For martensitic grades, for instance, a linearized expression holds in the concentration range from 0.15 to 0.6 m.% C. Microhardness depth profiles of higher carbon steels and other microstructures, however, are also evaluated in the literature. The applicability of quantitative diffusion modeling is discussed in detail. Through hardenable rolling bearing steel 100Cr6 (1.3505, SAE 52100) serves as model material: carbon concentration-distance curves are measured with high accuracy by secondary ion mass spectrometry (SIMS) and compared with microhardness decarburization ...

2007-07-01

495

Review of progress in quantitative NDE. Abstracts  

Energy Technology Data Exchange (ETDEWEB)

The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; x rays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...

1986-01-01

496

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with ...

2006-01-01

497

FEM Analysis and Measurement of Residual Stress by Neutron Diffraction on the Dissimilar Overlay Weld Pipe  

International Nuclear Information System (INIS)

Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-ray method and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic Energy Research Institute). Secondly, FEM Model on the ...

2010-10-01

498

Evaluation of passive films by photo and impedance spectroscopy; Bunkoho oyobi inpidansu ho ni yoru himaku hyoka  

Energy Technology Data Exchange (ETDEWEB)

The passive films formed on iron metal, alloys or stainless steel are extremely thin oxides or hydroxides and possess the properties of high chemical stability in the environment. These films show characteristics interested both electrical as well as electrochemical point of view due to the thin thickness of the films. Auger Electron Spectroscopy, X-ray Photoelectron spectroscopy and so on which are the conventional electrochemical measurement methods or the surface analysis methods are used for the analysis and evaluation of these films, however, at present, the application of research technique focusing the superconductor characteristics of the films are tried. Although, the potential modulation reflection spectroscopy method has merits like possibility of in-situ measurement, high precision, possibility of stable analysis even for extremely thin film and so forth, it has also demerits like difficulty to response the ...

1995-09-20

499

Enhanced corrosion resistance of Fe_4_0Ni_3_8Mo_4B_1_8 and Nd_1_5Fe_7_7B_8 by laser glazing  

International Nuclear Information System (INIS)

Laser glazing, using a KrF excimer laser (> = 248 nm, >a = 22 ns), has been used to improve the corrosion resistance properties of crystallized Fe_4_0Ni_3_8Mo_4B_1_8 (Metglas 2826 MB) and the permanent magnet material Nd_1_5Fe_7_7B_8. The formation of an amorphous layer was confirmed by conversion-electron Mossbauer Spectroscopy (CEMS), and the thickness of the amorphous layer was determined from the attenuation of the x-rays diffracted from the underlying crystalline material. The variation with laser fluence of the amorphous layer thickness on the Metglas were measured. The corrosion properties of the original, crystalline and laser glazed Metglas were measured potentiodynamically in acid electrolyte. Similar voltametric characteristics were obtained for the laser glazed surface and original Metglas, both showing a lower current in the passive region than the crystalline material. Laser glazing of the ...

1988-09-21

500

4U 1907+09: a HMXB running away from the Galactic plane  

CERN Document Server

We report the discovery of a bow shock around the high-mass X-ray binary (HMXB) 4U 1907+09 using the Spitzer Space Telescope 24 $\\mu$m data (after Vela X-1 the second example of bow shocks associated with HMXBs). The detection of the bow shock implies that 4U 1907+09 is moving through the space with a high (supersonic) peculiar velocity. To confirm the runaway nature of 4U 1907+09, we measured its proper motion, which for an adopted distance to the system of 4 kpc corresponds to a peculiar transverse velocity of $\\simeq 160 \\pm 115$ km/s, meaning that 4U 1907+09 is indeed a runaway system and supporting the general belief that most of HMXBs possess high space velocities. The direction of motion of 4U 1907+09 inferred from the proper motion measurement is consistent with the orientation of the symmetry axis of the bow shock, and shows that the HMXB is running away from the Galactic plane. We also present the Spitzer ...

2011-01-01